Induction Motor Control by Vector Control Method.: Miss. Bhagyashree Thool, Miss. Kalyani C. Wakhare
Induction Motor Control by Vector Control Method.: Miss. Bhagyashree Thool, Miss. Kalyani C. Wakhare
ABSTRACT:- The 3-phase alternating current (AC) induction motors are mechanically simple, rugged, highly
reliable, lower in cost per horsepower than DC motors and capable of more torque and efficiency than single-
phase AC motors. A 3-phase AC induction motor can be controlled by varying its inputs according to a
mathematical model of the rotor flux field in a complex vector space (vector control). Vector control provides
efficient and accurate control of the motors speed and torque. The vector control analysis of an induction
motor allows the decoupled analysis where the torque and the flux components can be independently controlled
(just as in dc motor). This makes the analysis easier than the per phase equivalent circuit.
Keywords: Constant Volts Per Hertz, dq Transformatn, Torque Speed Curve,.
I. INTRODUCTION
The induction motor, which is the most widely used motor type in the industry, has been favored
because of its good self-starting capability, simple and rugged structure, low cost and reliability, etc. Along with
variable frequency AC inverters, induction motors are used in many adjustable speed applications which do not
require fast dynamic response. The concept of vector control has opened up a new possibility that induction
motors can be controlled to achieve dynamic performance as good as that of DC or brushless DC motors.
The v/f control principle adjust constant volt-per Hertz ratio of the stator voltage by feed foreword
control. It serves to maintain magnetic flux in the machine at desired level .it satisfy only moderate dynamic
requirement .High dynamic performance is achieved by field orientation ,also called Vector control. The
technique called vector control can be used to vary the speed of an induction motor over a wide range. It was
initially developed by Blaschke (1971-1973). In the vector control scheme, a complex current is synthesized from
two quadrature components, one of which is responsible for the flux level in the motor, and another which
controls the torque production in the motor. Essentially, the control problem is reformulated to resemble the
control of a DC motor. Vector control offers a number of benefits including speed control over a wide range,
precise speed regulation, fast dynamic response, and operation above base speed. The vector control algorithm is
based on two fundamental ideas. The first is the flux and torque producing currents. An induction motor can be
modeled most simply (and controlled most simply) using two quadrature currents rather than the familiar three
phase currents actually applied to the motor. These two currents called direct (Id) and quadrature (Iq) are
responsible for producing flux and torque respectively in the motor. By definition, the Iq current is in phase with
the stator flux, and Id is at right angles. Of course, the actual voltages applied to the motor and the resulting
currents are in the familiar three-phase system. The move between a stationary reference frame and a reference
frame, which is rotating synchronous with the stator flux, becomes then the problem. This leads to the second
fundamental idea behind vector control. The second fundamental idea is that of reference frames. The idea of a
reference frame is to transform a quantity that is sinusoidal in one reference frame, to a constant value in a
reference frame, which is rotating at the same frequency.
This method is applicable only to the wound rotor motor as external resistance can be added to it through
the slip rings.
A MATLAB code was developed to observe the variation in Torque-Speed characteristics of a 3
induction motor with variable rotor resistance. Torque-Speed characteristics are shown in Figure [1]
Figure [4]: Block diagram for closed loop V/f control on a 3-IM
(2)
Substituting a = 0, the above equation can be written as below: (This is called stationary reference
frame)
(3)
Sometimes vector control includes calculation in rotor reference frame (frame is attached to the rotor
rotating at o). In this case, a = o in equation 2. Hence the matrix will be changed as
(4)
For dynamic simulation of induction motors, equation 3 or equation 4 may be used.
Also we have
Vqs = Rs Iqs + pqs +ws ds (5)
Vds = Rs Ids + p ds - ws qs (6)
0 = Rr Iqr + pqr + wr dr (7)
0 = Rr Idr + p dr - wr qr (8)
where flux linkage variables are defined by
qs = Ls Iqs + Lm Iqr (9)
ds = Ls Ids + Lm Idr (10)
qr = Lm Iqs + Lr Iqr (11)
Bapurao Deshmukh College of Engineering 20 | Page
Induction motor control by vector control method.
For any frame of reference, in terms of space vector instantaneous input power can be written as,
Pi = (3/2) Re(Vs Is )
Or
Pi = (3/2) [ Vds Ids + Vqs Iqs ]
The reactive power Qi can also be defined as
Qi = (3/2) Im(Vs Is )
Or
Qi = (3/2) [ Vqs Ids - Vds Iqs ]
Torque in terms of d-q parameters is given by
A MATLAB code was developed to observe the variations in q-axis and d-axis stator currents with
change in stator voltage for a three phase induction motor.
Figure [6]: Variation of q-axis stator current with change in stator voltage
Figure [7]: Variation of d-axis stator current with change in stator voltage
Table 1: Motor rating and parameters used in MATLAB code execution for Vector control
method
Rated Power 12 KW
Rated Stator Voltage (line to line) 230 V RMS
Operational frequency 50Hz
Number of Poles 4
Stator Resistance 0.095 ohms
Rotor Resistance 0.2 ohms
Stator Reactance 0.68 ohms
Rotor Reactance 0.672 ohms
Magnetizing Reactance 18.7 ohms
VIII. CONCLUSIONS
Torque-Speed characteristics for different methods of speed control of an IM were obtained and
analysed for different methods.
In rotor resistance control method the starting torque can be varied with the variation of rotor resistance.
The maximum torque however, remains unaffected. Thus for operations requiring high starting torque, the rotor
resistance can be varied to even obtain the maximum torque during starting. But simultaneously the copper losses
will increase due to increase of resistance. So this method is highly inefficient and cannot be used throughout the
operation. In variable supply voltage control method of speed control, the maximum torque decreases with the
decrease of supply voltage and thus the motor remains underutilized. So even this method cannot be used for
good performance.
In constant v/f control, by use of rectifier and PWM inverter, we can vary the supply voltage as well as
the supply frequency such that the ratio v/f remains constant so that the flux remains constant too. So we can get
different operating zone for various speeds and torques and also we can get different synchronous speed with
almost same maximum torque. Thus the motor is completely utilized and also we have a good range of speed
control.
The vector control method or the d-q axes model leads to a simpler analysis of an induction motor. A d-q
axes model with the d-axis aligned along the synchronously rotating rotor frame, leads to the decoupled analysis
where the torque and the flux components can be independently controlled just like in case of a dc motor.
REFERENCES
[1] IEEE Standard Test Procedure for Polyphase Induction Motors and Generators, volume 112, issue 1996 of IEEE, by IEEE Power
Engineering Society.
[2] A. E. Fitzgerald, Charles Kingsley, Jr. And Stephan D. Umans, Electrical Machinery, McGraw-Hills Publications, Year 2002 [3]
IEEE Standard Test Procedure for Polyphase Induction Motors and Generators, volume 112, issue 1996 of IEEE, by IEEE Power
Engineering Society
[3] Gopal K. Dubey, Fundamental Of Electrical Drives, Narosa Publication House, Second Edition, 2011
[4] www.Google.com
[5] www.wikipedia.com