Sir C.R.Reddy College of Engineering ELURU-534 007: Heat and Mass Transfer Lab Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 43

SIR C.R.

REDDY COLLEGE OF ENGINEERING


ELURU-534 007

HEAT AND MASS TRANSFER LAB


MANUAL

DEPARTMENT OF MECHANICAL ENGINEERING


SIR C.R.REDDY COLLEGE OF ENGINEERING

DEPARTMENT OF MECHANICAL ENGINEERING

HEAT AND MASS TRANSFER LAB

LIST OF EXPERIMENTS

Sl.No. Name of the Experiment Page No.


1 Heat Transfer in natural convection in vertical cylinder 2

2 Heat transfer in natural convection pin fin apparatus 5

3 Heat transfer in forced convection pin fin apparatus 9

4 Heat transfer in forced convection with variable flow rate 12


tube

5 Heat transfer in forced convection with constant flow rate 17


tube

6 H.T through composite wall 22

7 Test of emissivity measurement apparatus 25

8 Determination of steffen Boltzmans constant 28

9 Test on heat exchanger 31


- Parallel flow -Counter Flow

10 Critical Heat Flux Apparatus 35


11 Thermal Conductivity of Solids 38
12 Vapor Compression Refrigeration System 40

DEPARTMENT OF MECHANICAL ENGINEERING 1


SIR C.R.REDDY COLLEGE OF ENGINEERING

1.HEAT TRANSFER IN NATURAL CONVECTION VERTICAL


CYLINDER

Aim:
To determine surface heat transfer co-efficient for heated vertical cylinder in natural
convection.
Apparatus:
Equipment consists of vertical cylinder, heater, panel consisting of voltmeter,
ammeter, temperature indicators (digital type),dimmer and thermocouple selector
switch.

Description:
The apparatus consists of a vertical tube enclosed in a rectangular duct open at both
top and bottom. The duct is of sufficient dimensions so as not to interfere with the
connection process, while at the same time preventing external disturbances effecting
the data. One side of the duct is made of transparent glass to facilitate visual
observation. An electrical heating element embedded in the copper tube acts as heat
source. The surface temperatures of the tube are measured at different heights using
thermo couples. The surface of the tube is polished to minimize radiation losses. A
volt meter and an ammeter enable the determination of power dissipated by the heater
and hence heat input to the system. Different thermo couples can be selected using
thermo couple selector.

Procedure:
1. Connect the three-pin plug of the heater to main switch on the mains.
2. Rotate the dimmer to clock wise direction to give initial heat input to the
heater.
3. Allow the unit to stabilize.
4. Note down the voltage and current from respective meters.
5. Note down the temperature by operating thermo couple selector switch to
positions 1, 2, 3, 4, 5, 6, 7 and 8.
6. Repeat the experiment for different heat inputs and tabulate the readings for
calculation.

Precautions:
1. Input wattage to heater should be constant in one complete set of readings.
2. Temperature should be noted when the unit is in steady state condition.
3. There should not be any fluctuations in digital meters.

Specifications:
1. Diameter of the cylinder ( D ) = 45 mm
2. Length of the cylinder ( L ) = 450 mm

Calculations:

1. Heat input Q = VI watts

DEPARTMENT OF MECHANICAL ENGINEERING 2


SIR C.R.REDDY COLLEGE OF ENGINEERING

2.Mean surface temperature of cylinder

T 1 + T 2 + T3 + .+ T7
0
TS = --------------------------- C
7

Ts + T 8
3. Film temperature T f = ------------------ 0 C
2

0
4. Change in temperature T = T s -- T8 C

5. Surface area A = DL m2

6. Experimental surface heat transfer coefficient of the vertical cylinder

H exp =Q

Theoritical heat transfer coefficient :

7. Fluid properties of air at film temperature are obtained from data book.: ,

Cp, Pr, k, etc.

a. Grashoff number based on length= Gr = g L 3 T/ 2

S. Heat input Surface Temperature Ambient Temp. Film


N in 0C Temp. in difference T Temp.
o Volt Current Q in T1 T2 T3 T4 Avera 0
C T = T8
in 0C Ts T8 Tf in 0C
age I in Watts T5 T6 T7 ge fin Ts + T8
V in Amps temp.
Volt Ts 2
s

DEPARTMENT OF MECHANICAL ENGINEERING 3


SIR C.R.REDDY COLLEGE OF ENGINEERING

Non dimensional Surface heat Transfer


coefficient h in
Watts/m2 0C
Grash off number Prandtl number Nusse number Theoretical Experimental

VIVA QUESTIONS
1. What is convection?
2. Classify convection.
3. What is forced convection & natural convection?
4. Explain difference between forced convection and natural convection?
5. On which properties does convection heat transfer strongly depend?
6. Define convection heat transfer coefficient with dimensions.
7. Define Nussult number.
8. Develop velocity boundary layer for flow over a flat plate?
9. The Prandtl number will be lowest for------
10. What is significance of Nussults number in convection?
11. The hydro dynamic and thermal boundary layers are identical at Prandtl
number equal to-----
12. The temperature gradient in the fluid flow over a heated plate will be------
13. The ratio of heat transfer by convection to that by conduction is called-----
14. Define buoyancy force and discuss significance of the buoyancy force in
Natural convection?
15. Define volume expansion coefficient and discuss significance in Natural
convection?
16. Define Grashoff number and discuss significance of Grashoff number?
17. The free convection heat transfer is significantly affected by----
18. The dimension less parameter
(
g 3 l 3 t )
is called as----
3
19. The convective heat transfer coefficient from a hot cylindrical surface exposed
to still air varies in accordance with------
20. For Laminar conditions, the thickness of thermal boundary layer increases
with the distance from the leading edge in proportion to------

DEPARTMENT OF MECHANICAL ENGINEERING 4


SIR C.R.REDDY COLLEGE OF ENGINEERING

2.HEAT TRANSFER IN NATURAL CONVECTION PINFIN

Aim: To determine the heat transfer coefficient, fin efficiency and temperature
distribution along the length of a pinfin in natural convection.

Apparatus: PINFIN Apparatus.

Description of apparatus:
The apparatus consists of a pinfin of a placed inside an open duct (one side open) the
other end of the duct is connected to the suction side of the blower. The delivery side
of the blower is taken up through a gate value and an orificemeter to the atmosphere.
The air flow rate can be carried by the gate value and can be measured on the U tube
manometer connected to the orifice meter. A heater is connected to the pin fin and,
thermo couples are connected equidistance all along the length of the pin fine, sixth
thermo couple is left in the duct. The panel of the apparatus consists of voltmeter,
ammeter, digital type temperature indicator, dimmerstat to control power input to
heater, thermo couple selector switch, U-tube manometer and a schematic diagram.

Procedure:
1. Connect the three pin plug top to 230 V, 50 Hz, 15 Amp power socket.
2. Keep the thermo couple selector switch in ZERO position.
3. Turn the dimmer knob clockwise and set the power input to the heater to any
desired value by looking at the voltmeter and ammeter.
4. Allow the unit to stabilize.
5. Turn the thermocouple selector switch clock wise by step (1, 2, 3, ., 6).
6. Note down the temperatures indicated by the temperature indicator on each
step.
7. Repeat the experiment for different power input to the heater.
8. After the experiment for different power input to the heater position, keep the
thermo couple selector in ZERO position and disconnect the plug.

Precautions:
1. Power input should be stable.
2. Keep the Blower in OFF position.

Graph:
A graph is drawn taking thermo couple location (x) on x-axis and experimental
temperature on y-axis. Similarly another graph is drawn taking calculated temperature
on y-axis on the same sheet.

Observations:
1. Diameter of the Fin = D = 12 mm = 0.012 m.
2. Length of the Fin = l = 240 mm = 0.024 m.
3. Thermal conductivity of brass (Fin material) Kf
= Watts/ m0C
= Watts/ m0C

DEPARTMENT OF MECHANICAL ENGINEERING 5


SIR C.R.REDDY COLLEGE OF ENGINEERING

Calculation:
1. Heat transfer coefficient : (h)
T1 + T2 + T3 + T4 + T5
i) Average surface temperature of fin = TS = in 0C
5
0
ii) Ambinet temperature of the duct = TC = T6 in C
T + T 0
iii) Film temperature = Tf = 5 C
2
iv) Fluid properties are evaluated from data book at film temperature such
as K, P, v, pr etc.
v) Temperature difference T = TS - T

qTD 3
vi) Grass off number = where g is acceleration due to gravity.
2
vii) Nusselt number is given by
N U = 0.53(Gr Pr)1 / 4 for 10 4 < Gr Pr < 10 9
N U = 0.13(Gr Pr)1 / 4 for Gr Pr > 10 9
hD
viii) N U = = 0.85(Gr Pr)0.188 for 10 2 < Gr Pr < 10 4 where k is thermal
k
conductivity air at film temperature.
N K
Heat transfer coefficient = U
D
2. Efficient of fin : n

Actual heat transfered by fin


n fin =
Heat which would have been transferred in entire fin is at base temperature
tanh (ML)
=
ML
hp
Where M =
Kf A
P is perimeter of the fin = TID in M
A is cross sectional area of the fin /4 D2 in M2
Kfin is thermal conductivity of fin material (Brass)

3. Temperature distribution :
(T T )cos h (ML) X = 15 mm
i) TS = T + 1 1
cos h M(L X1 )
T2, T3, T4, T5 are calculated by choosing appropriate value of x
(T T )cos h M(L x )
T = T + S
cos h (ML)

DEPARTMENT OF MECHANICAL ENGINEERING 6


SIR C.R.REDDY COLLEGE OF ENGINEERING

S. Heat input Fin surface Temperature in Ambient Temp. Film Temp.


0
No C Temp. in 0C difference T Tf in 0C
Volta Current Q in T1 T2 T3 T4 T5 Averag T = T6 in 0C Tfav
ge V I in Wat e fin

T
Tfav + T

in
Volts
Amps ts temp.
Tfav
2

Non dimensional Heat Tranfer Fin efficiency


Grash off Prandtl Nusse coefficient h in hp f percentage
number number number Watts/m2 0C M=
Kf A

VIVA QUESTIONS

1. What is convection?
2. Classify convection.
3. What is forced convection & natural convection?
4. Explain difference between forced convection and natural convection?
5. Force convection in a liquid bath is caused by----
6. Explain Newtons law of cooling?
7. Give the relation between Fluid velocity and Heat transfer?
8. On which properties does convection heat transfer strongly depend?
9. Define convection heat transfer coefficient with dimensions.
10. Define Nussult number.
11. Develop velocity boundary layer for flow over a flat plate?
12. Explain Prandtl number.
13. Fluid properties are evaluated at what temperature?
14. The Prandtl number will be lowest for------
15. What is significance of Nussults number in convection?
16. The hydro dynamic and thermal boundary layers are identical at Prandtl
number equal to-----
17. The temperature gradient in the fluid flow over a heated plate will be------
18. The ratio of heat transfer by convection to that by conduction is called-----
19. Define buoyancy force and discuss significance of the buoyancy force in
Natural convection?
20. Define volume expansion coefficient and discuss significance in Natural
convection?
21. Define Grashoff number and discuss significance of Grashoff number?
22. What is significance of Rayleighs number?
23. The free convection heat transfer is significantly affected by----
24. The dimension less parameter
(
g 3 l 3 t )
is called as----
3
25. What is significance of Stanton number?

DEPARTMENT OF MECHANICAL ENGINEERING 7


SIR C.R.REDDY COLLEGE OF ENGINEERING

26. The convective heat transfer coefficient from a hot cylindrical surface exposed
to still air varies in accordance with------
27. For Laminar conditions, the thickness of thermal boundary layer increases
with the distance from the leading edge in proportion to------
28. What is the material used in pin fin experiment?

DEPARTMENT OF MECHANICAL ENGINEERING 8


SIR C.R.REDDY COLLEGE OF ENGINEERING

3.HEAT TRANSFER IN FORCED CONVECTION - PINFIN

Aim: To determine the heat transfer coefficient, efficiency and temperature


distribution of a pin fin in forced convection.

Apparatus:
The apparatus consists of pin fin in an open duct, blower, gate value an orifice meter,
a U manometer a heater along with thermocouples, Voltmeter and ammeters.

Procedure:
With air circulation: (Blower ON) forced convection
1. Connect the three pin plug top to a 230 V, 50 Hz, 15 A power socket, the
indicator lamp ON.
2. Keep the thermo couple selector switch in ZERO position.
3. Turn the dimmer knob clockwise and set the power input to the heater to any
desired value by looking at the voltmeter P ammeter.
4. Switch ON the blower.
5. Set the air flow rate at any desired value looking at the difference in U tube
manometer levels.
6. Allow the unit to stabilize.
7. Turn the thermo couple selector switch clockwise step by step (1, 2, 3, 4, 5)
8. Note down the temperature indicated by the temperature indicator on each
step.
9. Repeat the experiment by varying air flow rate and keeping the power input to
heater constant.
10. Tabulate all the readings and calculate for different conditions.
11. After experiment is over put OFF the blower, turn the dimmer knob anti-
clockwise you hear a click, keep the thermocouple selector in zero position,
disconnect the power supply.

Observations :

Diameter of the fin Df = 12 mm


Length of the fin L = 15 cm.
Thermal conductivity of brass (KL) = 100.4 watts/m 0k
Diameter fo the orifice d0 = 20 mm
Diameter of the pipe dp = 42 mm
Coefficient of discharge of orifice Cd = 0.61
Density of air a = 1.17 kg/m3
Width of the duct W = 15 cm.
Breadth of the duct B = 10 cm.

DEPARTMENT OF MECHANICAL ENGINEERING 9


SIR C.R.REDDY COLLEGE OF ENGINEERING

Calculation :
1. Calculation of velocity of air in duct:
2gho( m a ) 1
(a) Velocity of orifice V0 = C d
a 1
dia. of orifice 28
where = =
dia of pipe 42
g = 9.81, Cd = 0.61, a = 1.17 kg/m3, m = 1000 kg/m3

V0 C.S.Area. of orifice
(b) Velocity of air in the duct =
C.Sarea of duct

V0 do 2
Va = 4 m/s
wB
2. Reynolds number of air flow:
D VP
Re = f a a a = 1.8 10-5 kg m/s.
a
C P
Prandti number = at room temperature
K
= 0.7
hD f
Nusselt number =
Ka

3. Heat transfer coefficient relations:


Nu = 0.989 Re0.33 Pr1/3 for 1 < Re < 4
0.385 1/3
= 0.911 Re Pr for 4 < Re < 40
= 0.683 Re0.466 Pr1/3 for 40 < Re < 4000
0.6187 1/3
= 0.193 Re Pr for 4000 < Re < 40,000
= 0.0266 Re0.805 Pr1/3 for 40,000 < Re
Find heat transfer coefficient.

hp
4. M =
KbA
where h found previously
p is the perimeter of the fin Df
Kb thermo conductivity of brass.
AC sectional area of fin.
tan h (ML)
Efficiency of Fin = n fin =
(ML)

DEPARTMENT OF MECHANICAL ENGINEERING 10


SIR C.R.REDDY COLLEGE OF ENGINEERING

S.No Heat input Orifice drop Fin surface Ambient Velocity of


temps in 0C Temp. in 0C air in the duct
Voltage Current I Q mm of m of T1 T2 T3 T4 T = T6
Va m/s
V in in Amps in Watts water air T5
Volts

Mass of Non dimensional numbers Heat Tranfer Fin Heat


rate of air Reynolds Prandtl Nusselt coefficient h hp efficiency f transfer
ma kg/sec number Re number Pr number Nu in M= percentage rate Q
Watts/m2 0C Kf A Watts

VIVA QUESTIONS
1. What is convection?
2. Classify convection.
3. What is forced convection & natural convection?
4. Explain difference between forced convection and natural convection?
5. Force convection in a liquid bath is caused by----
6. Explain Newtons law of cooling?
7. Give the relation between Fluid velocity and Heat transfer?
8. On which properties does convection heat transfer strongly depend?
9. Define convection heat transfer coefficient with dimensions.
10. Define Nussult number.
11. Develop velocity boundary layer for flow over a flat plate?
12. What is drag force?
13. Define friction coefficient (or) drag coefficient?
14. Explain Reynolds number?
15. What is critical Reynolds number?
16. Explain Prandtl number.
17. Fluid properties are evaluated at what temperature?
18. For forced convection, Nussult number is a function of---------
19. The Prandtl number will be lowest for------
20. What is significance of Nussults number in convection?
21. The hydro dynamic and thermal boundary layers are identical at Prandtl
number equal to-----
22. The temperature gradient in the fluid flow over a heated plate will be------
23. The ratio of heat transfer by convection to that by conduction is called-----
24. What is significance of Stanton number?
25. The convective heat transfer coefficient from a hot cylindrical surface exposed
to still air varies in accordance with------
26. For Laminar conditions, the thickness of thermal boundary layer increases
with the distance from the leading edge in proportion to------
27. Which dimensionless number has a significant role in forced convection?
DEPARTMENT OF MECHANICAL ENGINEERING 11
SIR C.R.REDDY COLLEGE OF ENGINEERING

4.HEAT TRANSFER IN FORCED CONVECTION TUBE


VARIABLE FLOW

Aim: To find the heat transfer coefficient in forced convection of air in a tube
compare with predicted heat transfer coefficient.

Apparatus:
Tabular test section, Air heater, Flow straightener, Temperature indicators.

Description of apparatus:
The apparatus consists of a blower for supply of air. Air from blower passes through a
flow straightner and an air heater and then to the test section. Air flow is measured by
an orifice meter placed near the test section. Heating of air is done by band heater
placed around the tube, the voltage to the heater being controlled by a dimmerstat.
Temperature of the air at the in let to and outlet from the test section are measured
using thermo couples located in the air steam. Test section wall surface temperatures
are measured using thermocouples embedded in the walls at different axial distance
from the entrance. The test section is enclosed in a water jacket where the circulating
water removes heat from air. Water jacket is insulated to minimize heat lose by
radiation and convection to the surroundings. A by-pass line on the air systems
enables tests to be conducted at different Reynolds numbers. The next flux is varied
systematically by controlling the by pass value so that the manometer head across the
orifice varies uniformly.

Procedure:
1. Connect the three-pin plug to the mains. Switch on the mains.
2. Give the initial heat input to the heater. Switch on the blower when by pass
value fully open. Wait for few minutes.
3. Adjust the water flow rate such that it causes a temperature rise of at least 3 -
40C.
4. Allow the system to stabilize.
5. Heater input, water flow rate and orifice drop are recorded.
6. Note down the temperatures by rotating the thermo couple selector switch.
7. Repeat the experiment at different heat inputs and tabulate the corresponding
readings.

Precautions:
1. Airflow rate should be kept constant.
2. Blower is started when the value is fully open.
3. Heat input should be constant.

DEPARTMENT OF MECHANICAL ENGINEERING 12


SIR C.R.REDDY COLLEGE OF ENGINEERING

Calculations:
1. Mass flow rate of air through pipe (ma)
c a 2gh a
ma = d a kg / sec
1 4
where cd is the coefficient of discharge = 0.62 a is the cross sectional area of
orifice in m2 a is the density of air at room temperature.
273
a = at at is density at 00C = 1.296 kg/m3
273 + t
g is acceleration due to gravity.
ha is height of air column in m of water
h ( a )
ha = m m m of water.
a
hm is height of water column
m, a are densities of water, air in kg/m3
Diameter of orifice D O 20mm
= = =
Diameter of pipe D P 40mm
2. Average velocity of air (Va)
ma
Va = m/sec
a A1

where A1 is cross sectional area of pipe = D P 2
4
3. Heat balance in the process:
(a) Heat lost by air : Qa
Q a = MaC pa (Tai Tao ) Watts
where Cpa is the specific heat of air = 1.005 Kj/kg0C
Tai is the inlet air temperature
Tao is the outlet air temperature
ma in kg/sec
(b) Heat gained by water (Qw)
Qw = mw Cpw (Two Twi)
mw is the mass flow rate of water in kg/sec
Cpw is the specific heat of water
Two is the water outlet temperature
Twi is the water inlet temperature.

4. Heat transfer coefficient:


i. Surface area of the pipe = A = DpL
Where Dp is the diameter of pipe in m
L is the length of pipe in m.
T Tao
ii. Bulk temperature of air = Ti = ai
2

DEPARTMENT OF MECHANICAL ENGINEERING 13


SIR C.R.REDDY COLLEGE OF ENGINEERING

Where Tai is air inlet temperature


Tao is air outlet temperature
T + T3 + T4 + T5 + T6
iii. Average surface temperature To = 2
5
Qa
(a) Based on heat lost by air h a =
A(Ti To )
Qw
(b) Based on heat gained by water h a =
A(Ti To )
(c) Theoretical heat transfer coefficient:
Properties of air at 400C are (From data book)
= 16.96 10-6m2/sec. pr = 0.699
Va D p
Reynolds number R e =

Prandtl number : NU
Laminau flow Re < 2100
0.14
0.085N 6 Z b
N U = 3.66 + N 6Z < 100
1 + 0.04(N 6 Z )2 / 3 w
0.14

1/ 3
= 1.86(N 6 Z ) a N 6Z < 0
w
D
where N 6Z = R e pr p
L
b/w can be taken as 1 for rough calculations
as temperature air (bulk) and at wall are almost equal
Transition region : 2100 < Re < 10,000
0.14
D 2 / 3 b
(
2/3
)
N U = 0.116 Re 125 Pr 1 + 1 / 3
2 w


Turbulent region Re > 10,000
0.055
D
N U = 0.036 Re 0.8 Pr 1 / 3
2
NUKa
Theoretical heat transfer coefficient h m =
DP

DEPARTMENT OF MECHANICAL ENGINEERING 14


SIR C.R.REDDY COLLEGE OF ENGINEERING

S.No Heat input Orifice Water flow Air temperature in Tube surface temperature in 0C
0
drop rate (mw) C
Volta Curre Watta Hw H Ml/m Kg/s Inl Outl Bul T
ge V nt I in ge Q in a in ec et et k
T2 + T3 + T4 + T5 + T6
in Amps in m in Tai Tao tem
2
T
T0 =
5
volts Watts of m p. 3
wat of Ti T
er ai 4
r T
5
T
6

Full
openi
ng

Half
openi
ng

Quart
er
openi
ng

Water temp. in 0C Mass flow rate Average Heat balance in KW Heat transfer coefficient in
of air ma in velocity KW/m2 0C
of air
(Va) in
Inlet Twi Outlet Kg/sec Kg/sec m/s Heat Heat Nusselt Based Based Theoretical
Two lost gained number on on heat
by air by heat heat transfer
Qa water lost gained coefficient
Qw by air by
water

Full opening

Half opening

Quarter opening

VIVA QUESTIONS
1. What is convection?
2. Classify convection.
3. What is forced convection & natural convection?
4. Explain difference between forced convection and natural convection?
5. Force convection in a liquid bath is caused by----
6. Explain Newtons law of cooling?
7. Give the relation between Fluid velocity and Heat transfer?
8. On which properties does convection heat transfer strongly depend?
9. Define convection heat transfer coefficient with dimensions.
10. Define Nussult number.
11. Develop velocity boundary layer for flow over a flat plate?
12. What is drag force?
13. Define friction coefficient (or) drag coefficient?
14. Explain Reynolds number?
15. What is critical Reynolds number?
DEPARTMENT OF MECHANICAL ENGINEERING 15
SIR C.R.REDDY COLLEGE OF ENGINEERING

16. Explain Prandtl number.


17. Fluid properties are evaluated at what temperature?
18. For forced convection, Nussult number is a function of---------
19. The Prandtl number will be lowest for------
20. What is significance of Nussults number in convection?
21. The hydro dynamic and thermal boundary layers are identical at Prandtl
number equal to-----
22. The temperature gradient in the fluid flow over a heated plate will be------
23. The ratio of heat transfer by convection to that by conduction is called-----
24. What is significance of Stanton number?
25. The convective heat transfer coefficient from a hot cylindrical surface exposed
to still air varies in accordance with------
26. For Laminar conditions, the thickness of thermal boundary layer increases
with the distance from the leading edge in proportion to------
27. Which dimensionless number has a significant role in forced convection?

DEPARTMENT OF MECHANICAL ENGINEERING 16


SIR C.R.REDDY COLLEGE OF ENGINEERING

5.HEAT TRANSFER IN FORCED CONVECTION - TUBE

Aim: To find the heat transfer coefficient in forced convection of air in a tube
compare with predicted heat transfer coefficient.

Apparatus:
Tabular test section, Air heater, Flow straightener, Temperature indicators.

Description of apparatus:
The apparatus consists of a blower for supply of air. Air from blower passes through a
flow straightner and an air heater and then to the test section. Air flow is measured by
an orifice meter placed near the test section. Heating of air is done by band heater
placed around the tube, the voltage to the heater being controlled by a dimmerstat.
Temperature of the air at the in let to and outlet from the test section are measured
using thermo couples located in the air steam. Test section wall surface temperatures
are measured using thermocouples embedded in the walls at different axial distance
from the entrance. The test section is enclosed in a water jacket where the circulating
water removes heat from air. Water jacket is insulated to minimize heat lose by
radiation and convection to the surroundings. A by-pass line on the air systems
enables tests to be conducted at different Reynolds numbers. The next flux is varied
systematically by controlling the by pass value so that the manometer head across the
orifice varies uniformly.

Procedure:
1. Connect the three-pin plug to the mains. Switch on the mains.
2. Give the initial heat input to the heater. Switch on the blower when by pass
value fully open. Wait for few minutes.
3. Adjust the water flow rate such that it causes a temperature rise of at least 3 -
40C.
4. Allow the system to stabilize.
5. Heater input, water flow rate and orifice drop are recorded.
6. Note down the temperatures by rotating the thermo couple selector switch.
7. Repeat the experiment at different heat inputs and tabulate the corresponding
readings.

Precautions:
1. Airflow rate should be kept constant.
2. Blower is started when the value is fully open.
3. Heat input should be constant.

DEPARTMENT OF MECHANICAL ENGINEERING 17


SIR C.R.REDDY COLLEGE OF ENGINEERING

Calculations:
1. Mass flow rate of air through pipe (ma)
c a 2gh a
ma = d a kg / sec
1 4
where cd is the coefficient of discharge = 0.62 a is the cross sectional area of
orifice in m2 a is the density of air at room temperature.
273
a = at at is density at 00C = 1.296 kg/m3
273 + t
g is acceleration due to gravity.
ha is height of air column in m of water
h ( a )
ha = m m m of water.
a
hm is height of water column
m, a are densities of water, air in kg/m3
Diameter of orifice D O 20mm
= = =
Diameter of pipe D P 40mm
2. Average velocity of air (Va)
ma
Va = m/sec
a A1

where A1 is cross sectional area of pipe = D P 2
4
3. Heat balance in the process:
(a) Heat lost by air : Qa
Q a = MaC pa (Tai Tao ) Watts
where Cpa is the specific heat of air = 1.005 Kj/kg0C
Tai is the inlet air temperature
Tao is the outlet air temperature
ma in kg/sec
(b) Heat gained by water (Qw)
Qw = mw Cpw (Two Twi)
mw is the mass flow rate of water in kg/sec
Cpw is the specific heat of water
Two is the water outlet temperature
Twi is the water inlet temperature.

4. Heat transfer coefficient:


i. Surface area of the pipe = A = DpL
Where Dp is the diameter of pipe in m
L is the length of pipe in m.
T Tao
ii. Bulk temperature of air = Ti = ai
2
Where Tai is air inlet temperature

DEPARTMENT OF MECHANICAL ENGINEERING 18


SIR C.R.REDDY COLLEGE OF ENGINEERING

Tao is air outlet temperature


T2 + T3 + T4 + T5 + T6
i. Average surface temperature To =
5
Qa
(a) Based on heat lost by air h a =
A(Ti To )
Qw
(d) Based on heat gained by water h a =
A(Ti To )
(e) Theoretical heat transfer coefficient:
Properties of air at 400C are (From data book)
= 16.96 10-6m2/sec. pr = 0.699
Va D p
Reynolds number R e =

Prandtl number : NU
Laminau flow Re < 2100
0.14
0.085N 6 Z b
N U = 3.66 + N 6Z < 100
1 + 0.04(N 6 Z )2 / 3 w
0.14

1/ 3
= 1.86(N 6 Z ) a N 6Z < 0
w
D
where N 6Z = R e pr p
L
b/w can be taken as 1 for rough calculations
as temperature air (bulk) and at wall are almost equal
Transition region : 2100 < Re < 10,000
0.14
D 2 / 3 b
(
2/3
N U = 0.116 Re 125 Pr 1 + )
1 / 3
2 w


Turbulent region Re > 10,000
0.055
0 .8 1/ 3 D
N U = 0.036 Re Pr
2
NUKa
Theoretical heat transfer coefficient h m =
DP

DEPARTMENT OF MECHANICAL ENGINEERING 19


SIR C.R.REDDY COLLEGE OF ENGINEERING

S.N Heat input Orifice Water flow Air temperature Tube surface temperature
o drop rate (mw) in 0C in 0C
Volta Curr Watta Hw H Ml/ Kg/s Inl Outl Bul T T2 + T3 + T4 + T5 + T6
ge V ent I ge Q in a min ec et et k 2 T0 =
in in in m in Tai Tao tem T 5
volts Amp Watts of m p. 3
s wat of Ti T
er ai 4
r T
5
T
6




Water temp. in 0C Mass flow rate of Average Heat balance in KW Heat transfer coefficient in
air ma in velocity KW/m2 0C
of air
(Va) in
Inlet Twi Outlet Kg/sec Kg/sec m/s Heat Heat Nusselt Based Based Theoretical
Two lost gained number on on heat
by air by heat heat transfer
Qa water lost gained coefficient
Qw by air by
water

VIVA QUESTIONS

1. What is convection?
2. Classify convection.
3. What is forced convection & natural convection?
4. Explain difference between forced convection and natural convection?
5. Force convection in a liquid bath is caused by----
6. Explain Newtons law of cooling?
7. Give the relation between Fluid velocity and Heat transfer?
8. On which properties does convection heat transfer strongly depend?
9. Define convection heat transfer coefficient with dimensions.
10. Define Nussult number.
11. Develop velocity boundary layer for flow over a flat plate?
12. What is drag force?
13. Define friction coefficient (or) drag coefficient?
14. Explain Reynolds number?
15. What is critical Reynolds number?
16. Explain Prandtl number.
17. Fluid properties are evaluated at what temperature?
18. For forced convection, Nussult number is a function of---------
19. The Prandtl number will be lowest for------
DEPARTMENT OF MECHANICAL ENGINEERING 20
SIR C.R.REDDY COLLEGE OF ENGINEERING

20. What is significance of Nussults number in convection?


21. The hydro dynamic and thermal boundary layers are identical at Prandtl
number equal to-----
22. The temperature gradient in the fluid flow over a heated plate will be------
23. The ratio of heat transfer by convection to that by conduction is called-----
24. What is significance of Stanton number?
25. The convective heat transfer coefficient from a hot cylindrical surface exposed
to still air varies in accordance with------
26. For Laminar conditions, the thickness of thermal boundary layer increases
with the distance from the leading edge in proportion to------
27. Which dimensionless number has a significant role in forced convection?

DEPARTMENT OF MECHANICAL ENGINEERING 21


SIR C.R.REDDY COLLEGE OF ENGINEERING

6.HEAT TRANSFER THROUGH COMPOSITE WALL



Aim: To determine the overall heat transfer coefficient and to compare with that
from theoretical heat transfer coefficient of the composite wall.

Apparatus:
Composite wall apparatus, stop clock, measuring jar.

Description:
The apparatus consists of slabs of different materials of some thickness. The three
different materials are mild steel, asbestos and copper. The three slabs are clamped
both sides using bolts and nuts. On one side of the composite wall a heater is fitted.
End losses from the composite wall are minimized by providing heat flow across the
slabs and insulated at ends. Thermo couples are embedded at different places or
sections and three at different places at the same section to find out the average
temperature. On the outside of the wall cooling water jacket is provided which takes
away heat conducted through slabs. The mass rate of flow and increase of temperature
of water can be found out.

Procedure:
1. Connect the three pin plug of the apparatus to the mains and switch on the
mains.
2. Rotate the diameter to give initial input to the heater.
3. Adjust the water flow rate in the cooling chamber (below 20 ml/min)
4. Allow the unit to reach steady state condition. (Three is no change in
temperature at any section).
5. Note down the voltage and current form digital voltmeter and ammeter
respectively. Also the temperature at different points using thermo couple
selector switch.
6. Repeat the experiment by giving different heater inputs.

Precautions:
1. The wattage given to the heater should not exceed the capacity of the heater.
2. Note down the temperature only after steady state is reached.
3. The readings on digital meters should remain constant for a certain amount of
time.

Details of composite wall:


1. Diameter of the composite wall (D) = 100 mm.
2. Thickness of each wall L1 = L2 = L3 = 6 mm.
3. Thermal conductivity of mild steel = Watts/m0C.
4. Thermal conductivity of asbestos sheet = Watts/m0C.
5. Thermal conductivity of copper = Watts/m0C.

DEPARTMENT OF MECHANICAL ENGINEERING 22


SIR C.R.REDDY COLLEGE OF ENGINEERING

Calculation:
1. Mass flow rate of water : (mw)
Water flow rate V = ml/min.
Density of water = 1000 kg/m3
Mass flow rate mw = kg/hr

2. Heat gained by water : (Qw)


Qw = mw Cpw (Tw2 - Tw2) Watts
Where Cpw specific heat of water = 4.18 Kj/kg0C
Tw2 water outlet temperature in 0C
Tw1 water inlet temperature in 0C

3. Average temperature at the hot end of the composite wall Th1


T + T2 + T3
Th1 = 1 in 0C
3

4. Average temperature at the cold end of the composite wall Th2


T + T11 + T12
Th 2 = 10 in 0C
3
5. Overall heat transfer coefficient
Qw2
U exp = KW/m2 0C
A(Th1 Th 2 )

where A is heat transfer area = D 2 in m 2
4
6. Theoretical heat transfer conductance (UTh)
1
U Th = KW/m2 0C
L1 L 2 L 3
+ +
K1 K 2 K 3

S.N Heat input Temperatures in 0C Mass flow rate Overall heat transfer
o of water coefficient in KW/m2 0C
Voltag Curren T1 T Th Water temp ml/mi mw Experiment Theoretic
e V in t I in T2 h 2 n kg/se al Uexp al
Volts Amps T3
Tw1 Tw2 c Uth
T4 (T13 (T14
) )
.
T1
2

DEPARTMENT OF MECHANICAL ENGINEERING 23


SIR C.R.REDDY COLLEGE OF ENGINEERING

VIVA QUESTIONS

1. Define thermal conductivity?


2. For which material thermal conductivity is highest?
3. Why negative sign in Fouriers Law?
4. What are the units of thermal conductivity?
5. What is the first law of thermodynamics?
6. What is the second law of thermodynamics?
7. How is thermal conductivity measured practically?
8. Why are diamonds sinks used in cooling electronic components?
9. What is the physical mechanism of conduction in solids, liquids and gases?
10. What do you mean by cp?
11. What is the physical significance of thermal diffusivity?
12. Is heat transfer a scalar or vector quantity?
13. What do you mean by steady heat transfer and how does it differ from
transient heat transfer?
14. What is lumped system? How does heat transfer in a lumped system differ
from steady heat transfer?
15. How are ordinary and partial differential equations used in heat transfer
analysis?
16. What is a boundary condition? Explain.

DEPARTMENT OF MECHANICAL ENGINEERING 24


SIR C.R.REDDY COLLEGE OF ENGINEERING

7.TEST OF EMISSIVITY MEASUREMENT APPARATUS



Aim:
To measure the emissivity of the test plate surface

Apparatus:
Emissivity apparatus

Theory:
An ideal black surface is one which absorbs all the radiation falling on it. Its
reflectivity and transmissivity is zero. The radiation emitted per unit time per unit area
from the surface of the body is called emissive power. It is denoted by

The emissivity of a surface to the emissive part of a black surface at the same
temperature. For a black body absorptivity is 1 and by kirchoffs law its emissivity is
1. Emissivity depends on the surface temperature and the nature of the surface.

Procedure:
1. Connect the three-pin plug to main.
2. Keep the heater selector switch in position (1) & rotate the main water dimmer
clockwise & adjust the power input to any desired value by looking at
voltmeter & ammeter starting from lower power input.
3. Keep the heater selector switch I position (2) & rotate the guarded heater
dimmer clockwise & adjust the power input to required value by looking at
panel board. Keep the voltage guarded heater slightly lower than the main
heater.
4. Allow the heater unit to stabilize the corresponding power inputs.
5. When the temperature of the thermocouple (3), (5) are equal note down the
temperature of various thermocouples located by rotating thermo-couple
selector.
6. Repeat the experiment for different power inputs to the main heater &
corresponding input to the guarded heater.
7. Tabulate the readings & calculate thermal conductivity of materials.
8. After experiment to over turn both the dimmer knobs in anti-clockwise
direction till you heat a check burning back the voltmeter & ammeter &
thermo-couple selector switch to zero position disconnect three-pin plug from
mains.

Precautions:
1. The voltage of guarded heater should not be less than that of mains heater in
order to restart the main heater.
2. Readings must be taken only after steady state is reached i.e. temperature of
thermocouple (3) + (5) are equal.

DEPARTMENT OF MECHANICAL ENGINEERING 25


SIR C.R.REDDY COLLEGE OF ENGINEERING

Model calculations:
1. Average black body temperature:
T + T2 + T3
Tb = 1
3
2. Average heat transfer temperature
T + T5 + T6
Ts = 4
3
3. Power input to black body:
[
Pb =b A b Tb4 T4 ]
b = emissivity of black body
Ab = Area of black surface

4. Power input to test sec/sc Ps =s A s Ts4 + T4 [ ]


4 4
T +T
b
Here s = 4

4
T +T
s

Voltag Curr Power Black surface Volt Current Power Test surface Chamber Emis
e in ent in temperature age in in temperature temperat sitivi
Volts in Watts T1 T2 T3 in Amps Watts T4 T5 T6 ure T =
ty
Amp Volts T7 s
s

VIVA QUESTIONS
1. Explain Radiation.
2. Heat energy transfers in radiation in which form?
3. What is a Block body?
4. Explain Stefan Boltzmans law? What is value of the Stefan Boltzman
contant?
5. Explain spectral blackbody emissive power?
6. Discuss Plancks distribution law.
7. Define emissivity.
8. Explain obsorptivity, reflectivity and transmissivity.
9. Define irradiation.
10. Explain Kirchoffs law.
11. Radiation between two surfaces mainly depends on-----

DEPARTMENT OF MECHANICAL ENGINEERING 26


SIR C.R.REDDY COLLEGE OF ENGINEERING

12. Define Shape factor (or) view factor (or) configure factor (or) angle factor
13. Explain Radiosity?
14. Explain Radiation Heat transfer between two surfaces?
15. What is network representation and what is its algebra?
16. Define Radiation shields?
17. Thermal radiation occur in the portion of electro magnetic spectrum between
the wavelengths -----
18. For infinite parallel plates with emissivities 1 and 2 shape factor for radiation
from surface 1 to surface 2 is ------

DEPARTMENT OF MECHANICAL ENGINEERING 27


SIR C.R.REDDY COLLEGE OF ENGINEERING

8.DETERMINATION OF STEFEN-BOLTZMANS CONSTANT



Aim: To determine the Stefen-Boltzman constant of radiation heat transfer.

Apparatus: Stafen_Boltzman apparatus consists of main switch, thermo couple


selector switch, Digital temperature indicator, Schematic diagram showing test
chamber with placement of thermocouples, water heating chamber with kettle element
fitted and a test chamber, thermo meter and a stop watch.

Description of Apparatus: The apparatus is centered on a flanged copper


hemisphere fixed on a flat non-conducting plates the outer surface of the hemisphere
is enclosed in a metallic water jacket used to heat the hemisphere to a suitable
temperature. On the hemispherical surface iron-constant thermo couples are attached
at various places. The disc is mounted on an isolated bakelite sleeve which is fitted in
a hole drilled in the center of the base plate. An iron-constantan thermo couple is used
to measure the temperature of the disc.

Procedure:
1. Drain water if any from the test chamber by opening the drain value and close
it.
2. Fill water into the water heating chamber upto 3/4 the capacity of the
chamber.
3. Remove thermo couple T4 from its position (From the bottom of the test
chamber)
4. Keep the thermo couple selector switch at ZERO position.
5. Plug the kettle heater plug into the main switch socket.
6. Connect the main three pin plug to 230 V, 50 Hz, 5 Amp power supply.
7. Put ON the main switch and wait till the water in the heating chamber
reaches 600C temperature by inserting stick thermo meter form top.
8. Put OFF the main switch.
9. Allow the hot water to flow into the test chamber by opening the tap provided
underneath the heating chamber till the hot water oozes out of the breather
hole provided on the top of the test chamber.
10. Close the tap and allow the unit to stabilize for some time.
11. Take down the temperatures of the thermocouples T1, T2, T3 recorded on the
temperature indicator by turning the thermocouple selector switch clock wise
in steps marked 1, 2, 3.
12. Inset the test thermocouple T4 into its position through the bottom hole of the
test chamber and simultaneously start a stop clock provided. Record the
temperatures of T4 at an interval of five seconds & 10 seconds by keeping the
selector switch at position 4.
13. Tabulate the readings and calculate.
14. Drain the test chamber water fully.
15. Refill the boiler to 3/4 of its capacity.
16. Switch on main switch.
17. Switch repeat experiment for different temperatures 700, 800C etc.

DEPARTMENT OF MECHANICAL ENGINEERING 28


SIR C.R.REDDY COLLEGE OF ENGINEERING

Graph:
A graph is drawn on temperature of the disc (T4) Vs time (t) in seconds. From graph
slope of the line = dT/dt

Model calculations:
Mass of the test disc M = 1.2 gms.
Specific heat of disc material (CP) copper = Watts/kg 0C
Diameter of the disc D = 20 mm.
T + T2 + T3
Temperature of the enclosure TE = 1 in 0K.
3
dT 0
From graph 1 slope of the line = C/sec.
dt
dT
Rate of heat absorbed by the disc Q = mC P Watts
dt
Q
Stefen Bolazman constant = 4 4
A(E TE S TS )
Where TS is the temperature of the disc material when it sis inserted i.e. T4 at 0
seconds.

A is the areas of the heat transfer = D 2
4
D is diameter of the disc, E = S = = 0.22

S.No Temperature Temperature of the TE TS From graph Heat Stefen
of water in the enclosure in 0C in in slope of the absorbed Boltzm
Boiler in 0C K K the disc Q an
T1 + T2 + T3 dT
T1 T2 T3 line Watts consta
3 dt nt





















DEPARTMENT OF MECHANICAL ENGINEERING 29


SIR C.R.REDDY COLLEGE OF ENGINEERING

VIVA QUESTIONS

1. Explain Radiation.
2. Heat energy transfers in radiation in which form?
3. What is a Block body?
4. Explain Stefan Boltzmans law? What is value of the Stefan Boltzman
contant?
5. Explain spectral blackbody emissive power?
6. Discuss Plancks distribution law.
7. Define emissivity.
8. Explain obsorptivity, reflectivity and transmissivity.
9. Define irradiation.
10. Explain Kirchoffs law.
11. Radiation between two surfaces mainly depends on-----
12. Define Shape factor (or) view factor (or) configure factor (or) angle factor
13. Explain Radiosity?
14. Explain Radiation Heat transfer between two surfaces?
15. What is network representation and what is its algebra?
16. Define Radiation shields?
17. Thermal radiation occur in the portion of electro magnetic spectrum between
the wavelengths -----
18. For infinite parallel plates with emissivities 1 and 2 shape factor for radiation
from surface 1 to surface 2 is ------

DEPARTMENT OF MECHANICAL ENGINEERING 30


SIR C.R.REDDY COLLEGE OF ENGINEERING

9.TEST ON HEAT EXCHANGER

Aim: To study and compare temperature distribution, heat transfer rate, overall heat
transfer coefficient in PARALLEL flow and COUNTER flow.

Apparatus:
Stop clock, measuring flask, thermometers etc. and heat exchanger equipment.

Specifications:
Length of the heat exchanger = 1200 mm
Inner tube Inner diameter = 9.5 mm
Outer diameter = 32 mm
Capacity of Geyser = 3 liters; wattage = 3 Kw

Description of Apparatus:
The apparatus consists of a concentric tube heat exchanger. The hot fluid i.e. hot
water is obtained from an electric geyser and it flow through inner tube. The cold
fluid i.e. cold water can be admitted at any one of the ends enabling the heat
exchangers to run as a parallel flow apparatus or a counter flow apparatus. This can
be done by operating the different values provided. Temperatures of the fluids can be
measures using. Flow rate can be measured using stop clock and measuring flask. The
outer tube is provided with adequate asbestos rope insulation to minimize the heat
loss to the surrounding.

Procedure:

1. Start the flow on hot water side.


2. Start the flow on cold water side.
3. Put on the electric geyser.
4. Adjust the flow rate on cold water side slightly higher than flow rate on hot
water side.
5. Adjust the flow rate same bill the steady state condition is reached.
6. Note the temperatures and measure the flow rate.
7. The experiment is repeated for parallel as well as counter flow head
exchanges.

Calculation: CP of water = 4.18 kj/kgk = 4180 j/kgk

Parallel flow:
1. Heat transfer from (LOST) hot water Qh = mh CPh (Thi - Tho) watts
2. Heat transfer to (GAINED BY) cold water QC = mC CPC (Tho - Thi) watts
mh mass of hot water kg/sec
mC mass of cold water kg/sec
3. Log mean temperature difference LMTD = hi
(T TCi ) (Tho TCo )
T TCi
in hi
Tho TCo

DEPARTMENT OF MECHANICAL ENGINEERING 31


SIR C.R.REDDY COLLEGE OF ENGINEERING

Qavg
4. Overall heat transfer coefficient U = m 2 0C.
A 3 (LMTD)
Qh + QC
Where Qavg =
2
Surface area of inner tube = AS = D0 L
D0 = To outer diameter of inner tube.
L = Length of the tube.

5. Effectiveness of heat exchanger : Cc > Ch


C (T TCi )
E = C CO
C min [Thi TCi ]
Actual heat transfer rate
=
Maximum possible heat transfer rate
Cc = mc Cpc Cmin = mh Cph
Counter flow:
1. Qh = mh Cph (Thi Tho) watts
2. Qc = mc Cpc (Tci Tco) watts
3. Log mean temperature difference = hi
(T TCo ) (Tho TCi )
T TCo
in hi
Tho TCi
Q au
4. Overall heat transfer coefficient U =
A S LMTD
M C (T TCi )
5. Effectiveness E = C PC CO
m h C h (Thi TCi )

Precautions:
1. Keep water flow rate same.
2. Temperature should be noted when steady state condition is reached.
3. Check the value for direction of flow of water in each case i.e., Parallel /
Counter flow.



Test On Heat Exchanger

S. Type of Hot water Cold water
No flow ml/sec Kg/sec Inlet Outlet ml/sec Kg/sec Inlet Outlet
temp. in temp. in 0C temp. in temp. in 0C
0C T T 0C T T
1 2 3 4 5 6 7 8 9 10
1 Parallel
Flow
2 Counter
Flow




DEPARTMENT OF MECHANICAL ENGINEERING 32
SIR C.R.REDDY COLLEGE OF ENGINEERING

Heat lost Heat gained Average heat transfer LMTD Overall heat Effectiveness
hot water by cold Q + QC transfer Co-eff.
Qn water QC Q au = h
2
11 12 13 14 15 16






VIVA QUESTIONS
1. Classify convection.
2. What is forced convection & natural convection?
3. Explain difference between forced convection and natural convection?
4. Force convection in a liquid bath is caused by----
5. Explain Newtons law of cooling?
6. Give the relation between Fluid velocity and Heat transfer?
7. On which properties does convection heat transfer strongly depend?
8. Define convection heat transfer coefficient with dimensions.
9. Define Nussult number.
10. Develop velocity boundary layer for flow over a flat plate?
11. What is drag force?
12. Define friction coefficient (or) drag coefficient?
13. Explain Reynolds number?
14. What is critical Reynolds number?
15. Explain Prandtl number.
16. Fluid properties are evaluated at what temperature?
17. For forced convection, Nussult number is a function of---------
18. The Prandtl number will be lowest for------
19. What is significance of Nussults number in convection?
20. The hydro dynamic and thermal boundary layers are identical at Prandtl
number equal to-----
21. The temperature gradient in the fluid flow over a heated plate will be------
22. The ratio of heat transfer by convection to that by conduction is called-----
23. Define buoyancy force and discuss significance of the buoyancy force in
Natural convection?

DEPARTMENT OF MECHANICAL ENGINEERING 33


SIR C.R.REDDY COLLEGE OF ENGINEERING

24. Define volume expansion coefficient and discuss significance in Natural


convection?
25. Define Grashoff number and discuss significance of Grashoff number?
26. What is significance of Rayleighs number?
27. The free convection heat transfer is significantly affected by----

28. The dimension less parameter


(g l t ) is called as----
3 3

3
29. What is significance of Stanton number?
30. The convective heat transfer coefficient from a hot cylindrical surface exposed
to still air varies in accordance with------
31. For Laminar conditions, the thickness of thermal boundary layer increases
with the distance from the leading edge in proportion to------
32. Which dimensionless number has a significant role in forced convection?
33. Explain about a heat exchanger.
34. Classify heat exchangers.
35. Which type of heat transfer takes place in heat exchangers?
36. What is fouling?
37. Classify fouling?
38. What is the relation between fouling and overall heat transfer coefficient?
39. Define heat capacity ratio?
40. Explain different methods to design heat exchangers?
41. Define LMTD
42. Explain LMTD for parallel flow
43. Explain LMTD counter flow
44. What is correction factor?
45. What is effectiveness?
46. Explain effectiveness in parallel and counter flow?
47. Expand NTU
48. The normal automobile radiator is a heat exchanger of which type?
49. The Condenser in a thermal power plant is an exchanger of which type?
50. The effectiveness of heat exchanger is given by-------

DEPARTMENT OF MECHANICAL ENGINEERING 34


SIR C.R.REDDY COLLEGE OF ENGINEERING

10.CRITICAL HEAT FLUX APPARATUS

Aim:
Determination of critical heat flux values at different bulk temperatures and to
observe the boiling phenomenon

Introduction:
When heat is added to a liquid from a submerged solid surface, which is at a
temperature higher than the saturation temperature of the liquid, it is usual for a part
of the liquid to change phase. This change of phase is called boiling.

The experimental setup is designed to study the pool boiling phenomenon up to


critical heat flux point. The pool boiling over the heater wire can be visualized in the
different regions up to the critical heat flux point at which the wire melts. The heat
flux from the wire is slowly increased by gradually increasing the applied voltage
across the test wire and the change over from natural convection to nucleate boiling
can be seen. The formation of bubbles and their growth in size and number can be
visualized followed by vigorous bubble formation and their immediate carrying over
to surface and ending this in the breaking of wire indicating the occurrence of critical
heat flux point. This is repeated for various temperatures of the water in the container
up to saturation temperature.

Specifications:
1. Glass container diameter : 200 mm, height 100 mm
2. Heater for initial heating (Nichrome wire) (R1) 1 KW
3. Test heater (Nichrome wire, size: 12 mm) (R2)
4. Length of the test heater (R2) 100 mm

Procedure:
1. Take sufficient amount of distilled water in the container.
2. See that both heaters are completely immersed.
3. Connect heater R1 and heater R2 across the studs and make the necessary
electrical connections.
4. Switch ON the heater R1.
5. Keep it on till we get the required bulk temperature of water in the container
say 500C, 600C, 700C up to the saturation temperature.
6. Switch OFF the heater R1.
7. Switch ON the test heater R2.
8. Gradually increase the voltage across it by slowly changing the variac position
and stop a while at each position to observe the boiling phenomenon on the
wire.
9. Increase the voltage till the wire breaks carefully note the voltage and current
at this point.
10. Repeat this experiment by altering the bulk temperature of water.

DEPARTMENT OF MECHANICAL ENGINEERING 35


SIR C.R.REDDY COLLEGE OF ENGINEERING

Precautions:
1. Keep the voltage to zero voltage position before starting the experiment.
2. Take sufficient water in to the container so that both the heaters are
completely immersed.
3. Connect the test heater wire across the studs tightly.
4. Do not touch water or terminal points after putting the switch in ON position.
5. Gently operate the variac in steps and allow sufficient time in between.
6. After the attainment of critical heat flux condition decrease the voltage slowly
and bring it to zero.

Observations:
1. Daimeter of test heater wire d = mm.
2. Length of the test heater L= mm
3. Surface area A = d x L= mm2

S.No Bulk temperature of Ammeter Voltage reading Critical heat


water reading (V) Volts flux
(T0)C (I) amps Q
A

Results:
The critical heat flux at various bulk temperatures of water can be calculated by the
following procedure:

Heat Input = V x I Watts


VI
Critical Heat Flux = w / m2
A
Peak heat flux in saturated pool boiling :

0.25 0.5
Q g (l v ) l + v
= V 2



A 24 v l

= Latent heat
Q
= Heat flux
A
= Liquid vapour surface tension
l = Density of Liquid
v = Density of vapour

The properties are evaluated at the liquid saturation temperature. It can can be
observed that the critical heat flux value goes on decreasing as the bulk temperature
approaches the saturation temperature.

DEPARTMENT OF MECHANICAL ENGINEERING 36


SIR C.R.REDDY COLLEGE OF ENGINEERING

VIVA QUESTIONS

1. What is pool boiling?
2. Define flow boiling?
3. Define sub cooled boiling?
4. Define saturated boiling?
5. Explain different regimes of pool boiling?
6. Explain Neucleate boiling?
7. Define film boiling?
8. Explain what is critical heat flux?
9. Explain how bubbles are formed in boiling?
10. Explain Leiden frost point?
11. What is Condensation?
12. Classify Condensation processes?
13. What is the condition for condensation?
14. Define film condensation?
15. Define drop wise condensation?
16. Explain flow regimes in film condensation?

DEPARTMENT OF MECHANICAL ENGINEERING 37


SIR C.R.REDDY COLLEGE OF ENGINEERING

11.THERMAL CONDUCTIVITY OF SOLIDS



Aim: To determine thermal conductivity of solid by the guarded plate method.

Apparatus:
Main heater, guarded heater, specimen, cold water circulation, panel consists of
voltmeter, ammeter, temperature (digital type) indicators, dimmer and selector switch
for main and guarded heaters, thermo couple selector.

Description:
Electrically heater, thermal guards are placed adjacent to the exposed surface of heat
source H, specimen and heat pads. The guards are independently maintained at the
temperature at the adjacent surfaces. So that ideally no heat leakage occurs from the
source used in the computation of thermal conductivity of specimen is equal to and
not less than that actual passing through.

The heat source is an electric plate heater. The input which is measured using a
voltmeter an ammeter. Thermal couples are located on either side of the specimen.
The whole assembly is enclosed in insulated layer of mineral wool to prevent
radiation and convection losses upto the extent. Cooling water sources are provided at
the end to minimize the heat loss. Panel consists of ammeter, voltmeter, temperature
indicators all are of digital type, two dimmer controls, temperature indicators all are
of digital type, two dimmer controls main and guarded heaters selector and thermo
couple selector switches.

Procedure:
1. Connect the three pin plug to the mains.
2. Keep the heater selector switch in position 1 and rotate the main heater
dimmer clockwise and adjust the power input to any desired value by looking
at voltmeter and ammeter starting form lower power input.
3. Keep the heater selector switch in position 2 and rotate the guarded heater
dimmer clockwise and adjust the power input to the required value by looking
at panel board. Keep the voltage of guarded heater slightly lower than main
heater (2V).
4. Allow the unit to stabilize at corresponding power inputs.
5. When the temperatures of thermocouples 3 and 5 are equal, note down the
temperature at various thermo couple locations by rotating thermo couple
selector.
6. Repeat the experiment for different power inputs to the main heater and
corresponding inputs to the guarded heater.
7. Tabulate all reading and calculate thermal conductivity of material.
8. After experiment is over turn both the dimmer knobs anti clockwise direction
till you hear a click, bring back the voltmeter, ammeter and thermo couple
selector switch to ZERO position, disconnect the three pin plug from the
mains.


DEPARTMENT OF MECHANICAL ENGINEERING 38


SIR C.R.REDDY COLLEGE OF ENGINEERING

Precautions:

1. The voltage of guarded heater should be less than that of the main heater (2 V) in
order to restrict the heat transfer side ways.
2. Readings must be taken only after steady state is reached i.e. temperature of
thermo couples 3 and 5 are equal.

S. Main heater Guarded heater Temperature across two specimens 0C K
N W
o /
Volt Amp Volts Amp T1 T2 T3 T4 T5 T6 T7 T8 T9 m0
s s s K








VIVA QUESTIONS

1. Define thermal conductivity.
2. For which material thermal conductivity is highest?
3. Why negative sign in Fouriers Law?
4. What are the units of thermal conductivity?
5. What is the first law of thermodynamics?
6. What is the second law of thermodynamics?
7. How is thermal conductivity measured practically?
8. Why are diamonds sinks used in cooling electronic components?
9. What is the physical mechanism of conduction in solids, liquids and gases?
10. What do you mean by cp?
11. What is the physical significance of thermal diffusivity?
12. Is heat transfer a scalar or vector quantity?
13. What do you mean by steady heat transfer and how does it differ from
transient heat transfer?
14. What is lumped system? How does heat transfer in a lumped system differ
from steady heat transfer?
15. From heat transfer point of view, what is the difference between isotopic and
un isotopic materials?
16. What is heat generation in a solid?
17. How are ordinary and partial differential equations used in heat transfer
analysis?
18. What is a boundary condition? Explain.
19. What is the material for which thermal conductivity is to be found in thermal
conductivity of solids experiment?


DEPARTMENT OF MECHANICAL ENGINEERING 39


SIR C.R.REDDY COLLEGE OF ENGINEERING

12.VAPOR COMPRESSION REFRIGERATION SYSTEM



INTRODUCTION:

The vapor compression system is the most important system from the view point of
commercial of domestic utility. It is the most practical form of refrigeration. In this
system the working fluid is vapor. It readily evaporates, condenses (or) changes
alternating between the vapor and liquid phases without leaving the refrigerant plant
during evaporation. It absorbs heat from the cold body. This heat is used as its latent
heat for converting it from the liquid to vapor. The condensing (or) cooling (or)
liquefying it rejects heat to external body thus creating a cooling effect in the working
fluid this system thus acts as a latent heat pump. Since to pump its latent heat from the
cold body (or) bring of rejects it can delivers it to the external hot body (or) cooling
medium. The principle upon which the vapor compression system works apply to all
the gases for which tables of thermodynamic properties are available.

Simple vapor compression cycle:


In a simple vapor compression system fundamental process are computed in one
cycle. There are.
1. Compression
2. Condensation
3. Expansion
4. Vaporization

The vapors at low temperature and pressure enters the Compressor where it is
compressed isentropically of subsequently its lamp of pressure increase considerably
this vapor after leaving the compressor enters the condenser where it is considered
into high pressure liquid of it is collected in a receives tank from it is throttled down
to a lower pressure of has a low temperature. After finding its way through expansion
value it finially panes on to evaporator where is extracts heat from the surroundings
(or) circulating fluid being refrigerated & vaporizes to low pressure vapor actual
vapor compression cycle.

The actual vapor compression cycle differs from the theoretical cycle in several ways
because of the following reasons:

1. Frequently the liquid refrigerant is sub cooled before it is allowed to enter the
expansion value, of usually the gas leaving the evaporator a few degree before
it enters the compressor. This super heating may occur as a result of the type
of expansion control used (or) through a pick up of heat in the suction line
between the evaporator and compressor.
2. Compression, although usually assumed to be isentropic may actually prove to
be neither isentropic (nor) poly-tropic.
3. Both the compression suction of discharge valves are actuated by pressure
difference & this process requires the actual suction pressure inside the
compressor to be slightly below that of the evaporator and the discharge
pressure to be above of condenser.
4. Although isentropic compressor assumes no heat transfer between the
refrigerant of the cylinder walls, actually the cylinder walls are hotter than the

DEPARTMENT OF MECHANICAL ENGINEERING 40


SIR C.R.REDDY COLLEGE OF ENGINEERING

in coming gases from the evaporator of cooler than the than the compressed
gases discharged to the condenser.
5. Pressure drop in loop suction & liquid line piping and any vertical difference
in head created by locating the evaporator & condenser at different elevations.

The various process of a actual vapor compression cycle on T-S diagram are
discussed as follows:

Process 1-2-3 : This process represents passage of refrigerant through the evaporator,
with 1-2 indicating gain of latent heat of vaporization & 2-3 the gain of super heat
before entrance to compressor both of these process approach very closely to the
construct pressure conditions.

Process 3-4-5-6-7-8: This path entrance to the discharge of the compressor path 3-4
represents the throttling action that occurs during passage through the suction values,
and path 7-8 represents the throttling during passage through exhaust values both of
thus electrons drop it temperature.

Compression of the refrigerant occurs along 5-6, which is actually neither isentropic
nor poly-tropic. The heat transfer indicated by path 4-5 & 6-7 occurs essentially at
constant pressure process.

Process 8-9-10-11: This process represents the passage of refrigerant through the
condenser with 8-9 indicating removal of super heat, 9-10 the removal of latent heat
& 10-11 represents removal of liquid (or) sub-cooling.

Process 11-1: This process represents passage of the refrigerant through the expansion
value both theoretically of practically an irreversible adiabatic path.

Model calculation:
P1 = Pressure at inlet of condenser
P2 = Pressure at exit of condenser
P3 = Pressure after expansion
P4 = Pressure at return to compressor
T1 = Temperature after compression
T2 = Temperature after condensation
T3 = Temperature after expansion
T4 = Temperature at section to compressor

H1 (T4, P4) = enthalpy at the suction of compressor (kj/kg)


H2 (T1, P1) = enthalpy at delivery of compressor
H3 (T2, P2) and H4 (T3, P3) = enthalpy at throttling.
The above enthalpies corresponding to pressure P1, P2, P3 & P4 and corresponding
temperature is calculated from the pressure v/s enthalpy chart provided.

H1 H 3
1. Co-efficient of performance =
H 2 H1
50
2. Weight of refrigeration = W =
H1 H 3
DEPARTMENT OF MECHANICAL ENGINEERING 41
SIR C.R.REDDY COLLEGE OF ENGINEERING

1 ton of refrigeration = 210 kj/min


3. Theoretical power = W (H2 H1) (compressed work)
4. Quantity of heat rejected to condenser = W (H2 H3) kj/min


S.No Time Temperature Pressure Time taken Power
(min) T1 T2 T3 T4 P1 P2 P3 P4 for 5 rev input



VIVA QUESTIONS

1. Define TON of refrigeration.
2. What are the important properties of refrigerants?
3. What are the common refrigerants used in vapor compression refrigeration?
4. Draw the P H diagram for vapor compression refrigeration cycle.
5. Draw the T S diagram for vapor compression refrigeration cycle.
6. What do you mean by dry compression?
7. What do you mean by wet compression?
8. What is the importance of capillary tube in vapor compression cycle?
9. Which type of compressor is used for domestic refrigerator?
10. What do you mean by hermitically sealed compressor?
11. What are the disadvantages of wet compression?
12. Define dryness factor.
13. What are the refrigerants, which cause Ozone layer depletion?
14. What is the chemical that is responsible for Ozone layer depletion?
15. What do you mean by global warming?
16. What are the Eco-friendly refrigerants?
17. What are the harmful effects of Ozone layer depletion?
18. What are the harmful effects of global warming?

DEPARTMENT OF MECHANICAL ENGINEERING 42