Todays Oscilloscope

Quick Setup Tips


Vertical controls Trigger controls
1 Connect oscilloscope probes to 4 Adjust Vertical Scale and position to Define a
device under test (DUT). observe all channels. trigger event
to synchronize
2 Press Default Setup. 5 Press Trigger Level knob to set waveform
capture.
triggering at the 50% level.
3 Turn on all channels that have input Source: Select which channel to trigger on.
Scale (larger knob for each input channel):
Control height of waveform in units of volts/division. signals. 6 Adjust Horizontal Scale to view a few Slope: Select rising or falling edge to trigger on.

Position (smaller knob for each input channel): cycles of the waveform. Level (knob): Set the voltage value on the
waveform for triggering.
Control up and down position of waveform.
Keysight InfiniiVision X-Series Oscilloscope Auto Mode: Capture waveforms with or without a trigger
event occurring.

Horizontal controls Normal Mode: Capture waveforms only when a trigger


event occurs.

Run controls
Scale (larger knob): Control width of waveforms in
units of seconds/division.
Position (smaller knob): Control left and right
position of waveform.
Zoom : Show expanded view of waveforms.
Run: Capture waveforms continuously.

Save/Recall Stop: Display last captured waveform.


Single: Perform a single acquisition when the next
trigger event occurs.
Default Setup: Reset scope to a default
configuration. (Good practice: Begin new
Save and recall setups, waveforms and bitmap measurements with a Default Setup.)
images to a USB memory stick. Auto Scale: Automatically set up vertical and
horizontal scale and triggering.

Built-in quick help Measure


Press and hold in any key for instant help for that
function/feature.
Cursors: Perform voltage and timing measurements
using manually controlled cursors.
Waveform display area shows waveforms graphically, USB port Use the built-in function generator to simulate a variety Input up to 2 signals using Automatic measurements: Perform automatic
typically in volts (vertical axis) versus time (horizontal of electrical signals like AM and FSK modulation. oscilloscope probes or BNC cables measurements, such as voltage peak-peak, rise
axis). The display area is divided into divisions using
vertical and horizontal grid lines.
time, pulse width, etc.

Download the Oscilloscope Lab Guide/Tutorial and Oscilloscope Fundamentals slide set at
This information is subject to change without notice.
www.keysight.com/find/edk Keysight Technologies, 2014 - 2017, Published in USA, January 23, 2017
5990-8694EN
www.keysight.com