GD-1220 SHF en 0006

Download as pdf or txt
Download as pdf or txt
You are on page 1of 176

SERVICE HANDBOOK

FACSIMILE
GD-1220/1221

Model: GD-1220/1221
Publish Date: April 2006
File No. SHE060007F0
R060121B2400-TTEC
Ver06_2009-05
2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved
Under the copyright laws, this manual cannot be reproduced in any form without prior written permission
of TOSHIBA TEC CORPORATION. No patent liability is assumed, however, with respect to the use of the
information contained herein.
GENERAL PRECAUTIONS REGARDING THE SERVICE FOR
e-STUDIO165/167/205/207/237 AND GD-1220/1221
The installation and service should be done by a qualified service
technician.

1) Transportation/Installation
- When transporting/installing the equipment, employ two persons and be sure to hold the posi-
tions as shown in the figure.
The equipment is quite heavy and weighs approximately 32 kg (70.55 lb), therefore pay full atten-
tion when handling it.

- Be sure not to hold the movable parts or units when transporting the equipment.
- Be sure to use a dedicated outlet with AC 110 V / 13.2 A, 115 V or 127 V / 12 A, 220-240 V or 240
V / 8 A for its power source.
- The equipment must be grounded for safety.
- Select a suitable place for installation. Avoid excessive heat, high humidity, dust, vibration and
direct sunlight.
- Provide proper ventilation since the equipment emits a slight amount of ozone.
- To insure adequate working space for the copying operation, keep a minimum clearance of 80
cm (32) on the left, 80 cm (32) on the right and 10 cm (4) on the rear.
- The equipment shall be installed near the socket outlet and shall be easily accessible.
- Be sure to fix and plug in the power cable securely after the installation so that no one trips over
it.

2) General Precautions at Service


- Be sure to turn the power OFF and unplug the power cable during service (except for the service
should be done with the power turned ON).
- Unplug the power cable and clean the area around the prongs of the plug and socket outlet once
a year or more. A fire may occur when dust lies on this area.
- When the parts are disassembled, reassembly is the reverse of disassembly unless otherwise
noted in this manual or other related documents. Be careful not to install small parts such as
screws, washers, pins, E-rings, star washers in the wrong places.
- Basically, the equipment should not be operated with any parts removed or disassembled.
- The PC board must be stored in an anti-electrostatic bag and handled carefully using a wristband
since the ICs on it may be damaged due to static electricity.
Caution: Before using the wristband, unplug the power cable of the equipment and
make sure that there are no charged objects which are not insulated in the
vicinity.

08/08
- Avoid expose to laser beam during service. This equipment uses a laser diode. Be sure not to
expose your eyes to the laser beam. Do not insert reflecting parts or tools such as a screwdriver
on the laser beam path. Remove all reflecting metals such as watches, rings, etc. before starting
service.
- Be sure not to touch high-temperature sections such as the exposure lamp, fuser unit, damp
heater and areas around them.
- Be sure not to touch high-voltage sections such as the chargers, developer, high-voltage trans-
former and power supply unit. Especially, the board of these components should not be touched
since the electric charge may remain in the capacitors, etc. on them even after the power is
turned OFF.
- Make sure that the equipment will not operate before touching potentially dangerous places (e.g.
rotating/operating sections such as gears, belts pulleys, fans and laser beam exit of the laser
optical unit).
- Be careful when removing the covers since there might be the parts with very sharp edges
underneath.
- When servicing the equipment with the power turned ON, be sure not to touch live sections and
rotating/operating sections. Avoid exposing your eyes to laser beam.
- Use designated jigs and tools.
- Use recommended measuring instruments or equivalents.
- Return the equipment to the original state and check the operation when the service is finished.

3) Important Service Parts for Safety


- The breaker, door switch, fuse, thermostat, thermofuse, thermistor, batteries, IC-RAMs including
lithium batteries, etc. are particularly important for safety. Be sure to handle/install them properly.
If these parts are short-circuited and their functions become ineffective, they may result in fatal
accidents such as burnout. Do not allow a short-circuit or do not use the parts not recommended
by Toshiba TEC Corporation.

4) Cautionary Labels
- During servicing, be sure to check the rating plate and cautionary labels such as Unplug the
power cable during service, CAUTION. HOT, CAUTION. HIGH VOLTAGE, CAUTION.
LASER BEAM, etc. to see if there is any dirt on their surface and if they are properly stuck to the
equipment.

5) Disposal of the Equipment, Supplies, Packing Materials, Used Batteries and IC-RAMs
- Regarding the recovery and disposal of the equipment, supplies, packing materials, used batter-
ies and IC-RAMs including lithium batteries, follow the relevant local regulations or rules.

Caution:
Dispose of used batteries and IC-RAMs including lithium batteries according to this manual.
Attention:
Se dbarrasser de batteries et IC-RAMs uss y compris les batteries en lithium selon ce manuel.
Vorsicht:
Entsorgung der gebrauchten Batterien und IC-RAMs (inclusive der Lithium-Batterie) nach diesem Handbuch.

07/02
CONTENTS
GD-1220/1221

1. ERROR CODES ............................................................................................................ 1-1


1.1 Transmission/Reception Journal and Error Code List ......................................................... 1-1
1.2 Error Messages ................................................................................................................... 1-5
2. SELF-DIAGNOSIS MODE ............................................................................................ 2-1
2.1 Adjustment Mode (05) ......................................................................................................... 2-3
2.2 Setting Mode (08) ................................................................................................................ 2-4
2.3 Test Mode............................................................................................................................ 2-5
2.3.1 Function test ............................................................................................................. 2-5
2.3.2 MAINTENANCE ....................................................................................................... 2-9
2.3.3 SERVICE LIST ..................................................................................................... 2-133
2.3.4 Country/Region code............................................................................................ 2-137
2.3.5 Printer Unit Adjustment ........................................................................................ 2-138
3. TROUBLESHOOTING .................................................................................................. 3-1
3.1 Diagnosis Over Telephone .................................................................................................. 3-1
3.2 Recommend Flow Chart for Field Service ........................................................................... 3-2
3.3 Flow Chart for Recommended Telephone Screening.......................................................... 3-3
3.4 Error Analysis Flow.............................................................................................................. 3-6
3.4.1 Self-Diagnosis function............................................................................................. 3-6
3.4.2 Precautions for diagnosis ......................................................................................... 3-6
3.5 Fault Analysis ...................................................................................................................... 3-7
3.5.1 Power-ON is not possible ......................................................................................... 3-7
3.5.2 Original transport error ............................................................................................. 3-7
3.5.3 Recording paper transport error ............................................................................... 3-7
3.5.4 Image trouble ........................................................................................................... 3-7
3.5.5 Communication error ................................................................................................ 3-8
3.6 Lists Required at Problem in the Field................................................................................. 3-9
3.7 Other Information Required for Error Analysis................................................................... 3-15
4. PRECAUTIONS FOR INSTALLATION OF FAX UNIT ................................................. 4-1
4.1 Country/Region Setting........................................................................................................ 4-1
4.1.1 The FG harness on the NCU board ......................................................................... 4-1
4.1.2 Country/Region code................................................................................................ 4-2
4.2 Initialization .......................................................................................................................... 4-3

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


CONTENTS
1
GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved
CONTENTS
2
1. ERROR CODES

2. SELF-DIAGNOSIS MODE

3. TROUBLESHOOTING

4. PRECAUTIONS FOR INSTALLATION OF FAX


UNIT
4
1. ERROR CODES
1
1.1 Transmission/Reception Journal and Error Code List
The error condition on the equipment can be checked with the error message displayed on the LCD or
the error code printed on the transmission/reception journal.
The transmission journal is shown below. Refer to the error code list and status code list on the follow-
ing pages for "MODE" and "STATUS" in detail. The reception journal is printed in the same format.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


ERROR CODES
1-1
1) Error code list
If an error occurs during communication, an error code is printed in the STATUS column of the
transmission/reception journal. Clear the error, referring to the following list.
Error codes for service technicians are printed in the transmission/reception journal output in the
TEST MODE.

Code
Cause Remedy
Maintenance User
10 10 There was no recording paper or the Supply recording paper and insert the
paper cassette was not installed during paper cassette firmly.
the reception.
11 11 A recording paper jam occurred during Remove the jammed recording paper.
the reception.
12 12 A document jam occurred. Remove the jammed original, then try
the transmission again.
13 13 During the transmission, any cover was Attempt the transmission again.
opened and the transmission stopped.
20 20 A power failure occurred during the Attempt the transmission or reception
transmission or reception, and the trans- again.
mission/reception original data was lost.
30 30 The [CLEAR/STOP] key was pressed Attempt the transmission or reception
during the communication, and the com- again.
munication was stopped.
32 32 The set number of original pages did not Check the actual original count.
match the actual pages transmitted.
33 33 The polling password did not match, or Check the polling password or check if
no polling document existed. there is a polling original on the remote
partys side, and attempt the polling
reception again.
42 42 During a memory transmission or a Divide the originals into several trans-
memory reception, the machine ran out missions for a memory transmission.
of image memory. The machine's image For a memory reception, remove the
memory was exhausted. cause of the error, then ask the remote
party to transmit the original again.
50 50 Dialing and redialing was attempted as Confirm the phone numbers of the
many as the specified count but the line remote party.
was busy.
53 53 The password did not match in a Relay Confirm that both parties are using the
or Mailbox transmission, and the trans- same system password and the both
mission ended in failure. units are compatible. Then, ask the
remote party to transmit again.
B0 80 DIS (GI) could not detected. This may happen in some cases of bad
line condition. Attempt the transmission
again.
B1 82 DIS/NSF that cannot be handled by the This may happen in some cases of bad
sender is received. line condition. Attempt the transmission
The receiver received NSS/DCS other again or ask the remote party to attempt
than those declared by DIS/NSF. the transmission again.
B2 82 DCN is received. This may happen in some cases of bad
line condition. Attempt the transmission
again.
B3 80 DCS/DTC was not detected. This may happen in some cases of bad
line condition. Attempt the transmission
again.
B4 82 The sender performed fall-back but the This may happen in some cases of bad
transmission was not enabled. The line condition. Attempt the transmission
receiver was not detect TCF or detected again. Or ask the remote party to attempt
DCN after sending FTT. the transmission again.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


ERROR CODES
1-2
Code
Cause Remedy
Maintenance User
B5 80 CFR (FTT) was not detected. This may happen in some cases of bad 1
line condition. Attempt the transmission
again.
C0 85 Image signal carrier was not detected. This may happen in some cases of bad
line condition. Ask the remote party to
transmit again.
C1 83 High-speed signal was not detected on This may happen in some cases of bad
the receiving side. line condition. Ask the remote party to
transmit again.
C2 85 After detecting the image signal, carrier This may happen in some cases of bad
off was detected on the receiving side. line condition. Ask the remote party to
transmit again.
C3 83 After detecting a high-speed signal, EOL This may happen in some cases of bad
was not detected on the receiving side. line condition. Ask the remote party to
transmit again.
C4 83 The EOL timer has timed out. This may happen in some cases of bad
line condition. Ask the remote party to
transmit again.
D0 80 Post response signal was not detected This may happen in some cases of bad
on the sending side. line condition. Attempt the transmission
Post signal was not detected on the again. Or ask the remote party to attempt
receiving side. the transmission again.
D1 82 DCN is received. This may happen in some cases of bad
line condition. Ask the remote party to
transmit again.
D2 86 RTN/PIN/ERR is received on the send- This may happen in some cases of bad
ing side. line condition. Ask the remote party to
RTN/PIN/ERR is received on the receiv- transmit again.
ing side.
E0 21 A printer error occurred during a recep- Remove the cause of the printer error,
tion, and the machine is shifted into then ask the remote party to transmit
memory reception mode. How ever, again.
there was not enough residual memory.
E6 21 An error relating to the printer has Confirm details of the error using the
occurred. error code and correct the error. Then
ask the remote party to transmit again.
F0 83 The communication ended because of a Attempt the communication again. If the
watchdog timer due to an overrun of the error occurs frequently, perform a mem-
software. ory clear (except user area.)
F1 83 The communication ended because of Attempt the communication again. If the
an overrun of the software due to hard- error occurs frequently, perform a mem-
ware noises. ory clear (except user area.)

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


ERROR CODES
1-3
2) Status code list
The communication mode of each job can be confirmed with the 3-digit status code printed in the
MODE column of the transmission/reception journal.

Mode Transmission speed Resolution Encoding system


0 2400 8 x 3.85 MH
1 4800 8 x 7.7 MR
2 7200 8 x 15.4 MMR
3 9600 JBIG
4 12000 16 x 15.4
5 14400
6 V.34
7
8 300 x 300
9
A
B
C
D
E
F

[Example of the indication of a status code]

522
MMR (encoding system)
8 x 15.4 (resolution)
14400 (transmission speed)

For the combination of 14400 bps, 8x15.4 and MMR, as shown above, a status of 522 is indicate.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


ERROR CODES
1-4
1.2 Error Messages
Error messages are not displayed for the background jobs (memory transmission and memory recep-
tion). See the reception/transmission report for the details of the errors. 1
If an original jam during the direct transmission or recording paper jam during printing occurred, error
messages are displayed like when original jam occurred in the equipment.

Error messages and corrective actions


Display Cause Remedy
Line busy The destination is being used Wait for a while, then attempt transmission
so that transmission cannot again.
be performed.
Communication error A communication protocol This may happen in some cases of bad line
error has occurred. condition. Attempt transmission again. Or ask
the remote party to attempt the transmission
again.
Memory is full The image memory has over- Press the [CLEAR/STOP] key to clear the mes-
flowed. sage.
In memory transmission mode, transmit the
original divided into several transmit sequences,
or transmit the original again from the beginning
when enough memory is available.
In memory reception operation, correct the con-
dition which lead to the memory reception. Then
receive the original again.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


ERROR CODES
1-5
GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODES
1-6
2. SELF-DIAGNOSIS MODE
The followings are the modes which are added to (or extend) the PPC self-diagnosis function.

Self-diagnosis Modes
Mode For start Contents For exit

Adjustment mode [0]+[5]+[POWER] Adjusts various items. [POWER]OFF/ON


2
Setting mode [0]+[8]+[POWER] Sets various items. [POWER]OFF/ON

Function setting [1]+[3]+[POWER] Perform various test for [POWER]OFF/ON


mode maintenance.

Country/region set- [0]+[2]+[POWER] Sets country/region code -


ting mode

Memory clear mode [1]+[3]+[*]+[POWER] Clear various data in RAM -


[1]+[3]+[#]+[POWER]
[START]+[CLEAR/STOP]+[POWER]
[*]+[#]+[POWER]

Test Modes
Mode For start Contents For exit

AUTO TEST Press the [USER FUNCTIONS] but- Use this mode to diagnose Press the [USER
ton while REDAY is indicated, and the equipment by automati- FUNCTIONS] button,
then press the [*], [#], [*], [*] keys. cally performing a series of and then press the [*],
tests. [#], [*], [*] keys.

INDIVIDUAL TEST Use this mode to perform a


test dialogically and locate
a failure from the test
result.

TEST RESULT Use this mode to print the


LIST results of "AUTO TEST"
and "INDIVIDUAL TEST".

FUNCTION TEST Use this mode to check


each function of the equip-
ment.

MAINTENANCE Use this mode to perform


setups for Memory Clear,
Fax, etc.

SERVICE LIST Use this mode to print


PROTOCOL TRACE,
TOTAL ERROR, etc.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2-1
Note:
To enter the desired mode, turn ON the power while two digital keys designated to each mode
(e.g. [0] and [5]) are pressed simultaneously.

Power ON

[0][2] [1][3][*] [0][5] [0][8] [1][3]


[1][3][#]
[START][CLEAR/STOP] Adjust mode System mode Function test
[1][3]
Country/Region code RAM clear mode "INT" "INT"

Test print Power OFF

Warming up "INT":[INTERRUPT] key on.


*1
To user

Standby

*1 Turn OFF the power after using the self-diagnosis modes, and leave the equipment to the user.

Menu map
The menu below can be selected by pressing the USER FUNCTIONS key. (However, the menu in the
broken-dotted box are displayed only when the copier enters the SERVICE MODE.)

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2-2
2.1 Adjustment Mode (05)
Parameter setting for the FAX image processing is performed in the Adjustment Mode (05).

[Operation procedure]

Stores
value in RAM
[ENTER]
[0][5] Code(MC)
[ENTER]
Adjust a value [POWER] 2
[POWER] [Digital keys] [Digital keys] OFF/ON
Does not store
value in RAM
[CANCEL]

Adjustment codes for the image processing parameters


Image Accept-
Code Element Adjustment item Mode quality Default able
mode value

700 Density Adjustment of the threshold value for the binarization FAX Text 120 0 to 255
Center value

701 Density Adjustment of the threshold value for the binarization FAX Text 33 0 to 255
Lighter step value

702 Density Adjustment of the threshold value for the binarization FAX Text 33 0 to 255
Darker step value

710 Density Manual-density fine adjustment FAX Photo 128 0 to 255


Error diffusion, Center value

714 Density Manual-density fine adjustment FAX Text/ 128 0 to 255


Error diffusion, Center value Photo

715 Density Manual-density fine adjustment FAX Photo 33 0 to 255


Error diffusion, Lighter step value

719 Density Manual-density fine adjustment FAX Text/ 33 0 to 255


Error diffusion, Lighter step value Photo

720 Density Manual-density fine adjustment FAX Photo 33 0 to 255


Error diffusion, Darker step value

724 Density Manual-density fine adjustment FAX Text/ 33 0 to 255


Error diffusion, Darker step value Photo

725 Density Auto-density fine adjustment FAX Photo 128 0 to 255


Error diffusion

729 Density Auto-density fine adjustment FAX Text/ 128 0 to 255


Error diffusion Photo

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2-3
2.2 Setting Mode (08)
Parameters for the copy process are set in the Setting Mode (08).

[Operation procedure]

Stores
value in RAM
[ENTER]
[0][8] Code(MC) Adjust a value [POWER]
[ENTER]
[POWER] [Digital keys] [Digital keys] OFF/ON
Does not store
value in RAM
[CANCEL]

Image Default Acceptable


Code Element Setting item Mode
mode value value

857 Process Developer bias Hi 1 correction FAX - 128 0 to 128

818 Process Main charger bias correction FAX - 128 0 to 128

884 Process Laser output correction FAX - 128 0 to 128

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2-4
2.3 Test Mode
In test mode, there are various functions available for service technicians to test equipment during
maintenance.

2.3.1 Function test


The function test checks each function of the equipment. To enter the function test mode, follow the 2
procedure below, or enter the Service mode (*,#,*,*) and select the menu for the function test.

<Key used in operation> <Display messages>

1 3 Power ON

or Select test menu

ENTER

The following tests can be conducted in the function test mode.


This section only describes PRINT TEST and MODEM TEST as the functions available by attaching
the fax kit.
For the other tests, refer to the Service Handbook for e-STUDIO165/167/205/207/237.

01. OPE PANEL TEST


02. PRINT TEST
03. MODEM TEST (Factory test)*1
04. SENSOR TEST
05. SRAM TEST
06. DRAM TEST
07. CLOCK IC TEST
08. SCANNER TEST
09. CODEC TEST
10. OUTPUT TEST
11. PRINTER BOARD TEST*2

*1: When the FAX kit (GD-1220/1221) is not installed, the test is not present.
*2: When the Network Printer kit (GA-1190) is not installed, the test is not present.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2-5
08/08
[ 1 ] 02. PRINT TEST

<Key used in operation> <Display messages>

1 3 Power ON

02.PRINT TEST Select test menu

ENTER

Digital Keys Enter print code


P=

111
ENTER
Print code

Digital Keys Select paper cassette (C) 111


C=

ENTER
C
0: Bypass
1: Drawer
2: PFU
START 3: PFP upper drawer
4: PFP lower drawer

*1 *1: Be sure to press this key after printing starts.


CLEAR/STOP
(If this key is not pressed, the copier keeps printing)

* Be sure to press this key after printing starts. (If this key is not pressed, the equipment keeps print-
ing.)

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2-6
PRINT TEST ITEM
CODE FACTOR TEST PATTERN ITEM REMARKS
212 Image processing Grid pattern 16 dot x 15.4 l/mm FAX
213 Image processing Grid pattern 15.4 l/mm x 16 dot FAX

Test Pattern
<212> <213> 2

(10 square 147.6 mm 1%)

(10 square 153.4 mm 1%)


16 dot/mm

15.4 l/mm
15.4 l/mm 16 dot/mm
(10 square 153.4 mm 1%) (10 square 147.6 mm 1%)

The direction of transporting The direction of transporting

When the test print is carried out, the grid pattern is printed. For the adjustment procedure, refer to
P. 2-138 "2.3.5 Printer Unit Adjustment".

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2-7
[ 2 ] 03. MODEM TEST (Factory test)
When the FAX kit is not installed, the test is not present.
This test checks signal output from the modem.
The following signals are output at frequency that is changed every time the START key is pressed
once the test starts.

<Key used in operation> <Display messages>

1 3 Power ON

03.MODEM TEST Select test menu

ENTER

START *1
*1

CANCEL

* 1: The modems oscillation frequency changes every time the START key is pressed.

33600bps (V.34) 1100Hz

14400bps (V.17) 2100Hz

9600bps (V.29) 1300Hz

4800bps (V.27ter) ANSam

2400bps (V.27ter) CM

300bps CI

(To the top)

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2-8
2.3.2 MAINTENANCE

[ 1 ] MEMORY CLEAR
There are two ways to perform memory clear; the power on while pressing the specified keys, and
partial memory clear by selecting items to be cleared from the menu.

Operation Procedure
1) Memory clear at the startup 2
<Key used in operation> <Display messages>

Specified Keys Power ON

Warming up

READY(Standby)

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2-9
2) Item selection from menu

<Key used in operation> <Display messages>

USER FUNCTION Press the


USER FUNCTION key

Enter SERVICE MODE

05.TEST MODE Select menu

ENTER

05.MAINTENANCE Select test menu

ENTER

01.MEMORY CLEAR Use or keys

ENTER

Select menu Use or keys

ENTER
After
approx. 2
seconds

Memory is cleared.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 10
Memory clear table
RAM data Service parameter setting

Coun- Service Error


FUNC/ Service
try/ adjust- Jour- data on Proto- Count Drum
SYS- setting
Region ment nal FAX col er related
FUNC/ data
setting data report com- trace
Memory clear UAD
([0][5])
([0][8])
data muni- data data*2) data*3)
mode etc. area
area cation 2
[1] [3] [*] and turn Set Set Clear Clear Clear
ON default default
value value

[1] [3] [#] and turn Clear Clear


ON

[*] [#] and turn ON Clear Clear Clear

[START] [STOP] Set Set Clear


and turn ON default default
value value

[0] [8] and turn ON, Set Set Clear


then [6] [5] [5] *1) default default
value value

[0] [2] and turn ON Change Set Set Clear Clear Clear
able default default
value value

1.PIX MEMORY

2.EXCEPT USER Set Clear Clear


MEMORY default
value

3.ALL Set Set Clear Clear Clear


default default
value value

4.USER AREA

*1) In case of replacing the main board in the field, you can initialize the parameters related to copy
function stored on the board using this function.
Therefore when this function is performed, it is necessary to readjust the following items.
Adjustment of paper aligning value
Printer unit adjustment
Scanner unit adjustment
ADF/RADF installing setting
*2) Total Scan, Print jam, job counter, Counter for each paper size
*3) Total Print, Drum counter, Toner counter, etc.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 11
RAM data User parameter setting
Pend-
Depart-
Dial One Secure ing Stored
ment Station ID num- Pass-
touch receive FAX job
Memory clear data *1) data
code
data
name ber word *2) job data
mode data
data

[1] [3] [*] and turn Clear Clear Clear Clear Clear Clear Clear Clear Clear
ON

[1] [3] [#] and turn


ON

[*] [#] and turn ON Clear

[START] [STOP] Clear


and turn ON

[0] [8] and turn ON,


then [6] [5] [5] *1)

[0] [2] and turn ON Clear Clear Clear Clear Clear Clear Clear Clear Clear

1.PIX MEMORY Clear

2.EXCEPT USER Clear


MEMORY

3.ALL Clear Clear Clear Clear Clear Clear Clear Clear Clear

4.USER AREA Clear Clear Clear Clear Clear Clear Clear Clear

*1) One touch, Speed, Group etc.


*2) Polling Password

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 12
[ 2 ] SET FUNCTION
You can refer to and change the set values in each table (FUNC, PC FUNC, HOME, UAD, EX TYPE,
ACC DGT) for function programming.

<Key used in operation> <Display messages>

USER FUNCTION Press the


USER FUNCTION key
2
Enter SERVICE MODE

05.TEST MODE Select menu

ENTER

05.MAINTENANCE Select test menu

ENTER

02.SET FUNCTION Use or keys

CANCEL ENTER

Select function menu Use or keys

ENTER

Enter setting value

ENTER *1
*2

Bit 7 Bit 0

*1 : Displays the numeric value currently set (cannot be changed).


*2 : Displays the numeric value to be entered now (Can only be altered at the point of the cursor).

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 13
[A] FUNC 0-39
The settings here cover all the functions of this facsimile unit that can be adjusted by a service techni-
cian.
The functions consist of 40 tables in with each table having 8 bits (0 ~ 7).

FUNC 0
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Terminal ID entry for user 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


mode:
0: Disable
1: Enable

6 Undefined - - - - - - - - - - - - - - -

5 Program Continuous Poll- 1 1 1 1 0 0 1 0 1 1 1 1 1 1 1


ing open to users:
0: Disable
1: Enable

4 Exchange Type Setting for 0 1 1 1 1 1 1 1 1 1 1 1 1 1 0


User Mode:
0: Disable
1: Enable

3 Dial Type Setting for User 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1


Mode:
0: Disable
1: Enable

2 Undefined - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
FUNC 0 Bit 7:
This bit determines whether or not the Terminal ID programming operation is available to users.

FUNC 0 Bit 5:
This bit determines whether or not the Program continuous polling operation is made available to users.
Note:
When Prohibits setting by users is selected, PROG. CONT. POLLING is not displayed in poll-
ing programming.

FUNC 0 Bit 4:
This bit determines whether or not selection between PSTN and PABX is made available to users.

FUNC 0 Bit 3:
This bit determine whether or not selection between DP and MF is mode available to users.
Note:
When Disable is selected, the PSTN/PABX selection screen is not displayed in the dial type
setup menu.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 14
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR 2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

- - - - - - - - - - - - - - - - - - 6

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

0 0 1 0 0 0 1 1 1 1 1 1 1 1 0 0 1 0 4

1 1 0 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 15
09/02
FUNC 1
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 Download execute condi- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


tion (RDC):
0: No job in memory
1: Anytime

2 Remote access user set- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


ting:
0: Disable
1: Enable

1 EOL (End of Line) Timer 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


Value:
00: 5sec.
01: 6sec.
0 10: Undefined 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
11: 13sec.

<Remarks>
FUNC 1 Bit 3:
Upgrading (changing) the firmware normally clears all the Pending Jobs remained in the memory.

FUNC 1 Bit 2:
Set whether or not the remote access user setting.

FUNC 1 Bits 1 and 0:


These bits indicate the setting of the EOL (End of Line) check timer in high-speed image data.
Note:
Note: EOL is the code that is put between lines. If the next EOL is not detected within the time
specified in this setting, the line is disconnect due to communication error.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 16
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5 2
- - - - - - - - - - - - - - - - - - 4

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 17
09/02
FUNC 2
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 Frequency Detection 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Range to recognize as CI:
00: 12 Hz to 80 Hz
01: 16 Hz to 55 Hz
4 10: 20 Hz to 55 Hz 0 1 1 1 1 1 1 1 1 1 1 1 1 1 0
11: 22 Hz to 55 Hz

3 Undefined - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
FUNC 2 Bits 5 and 4:
These bits program the detection range for frequency to be recognized as CI.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 18
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5 2

0 0 1 0 0 0 1 1 1 1 1 1 1 1 0 0 1 0 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 19
09/02
FUNC 3
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Handing of Negative 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Answer (RTN/PIN):
0: Regards it to be abnor-
mal.
1: Regards it to be normal.

6 Undefined - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 Short Protocol: 1 0 0 1 1 1 1 0 1 0 0 1 1 0 1
0: Disable
1: Enable

3 Undefined - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
FUNC 3 Bit 7:
This bit programs whether or not a received RTN is handled as abnormal (NG).

FUNC 3 Bit 4:
This bit determines whether or not the Toshiba short protocol is enabled or disabled.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 20
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

2
- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 21
09/02
FUNC 4
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Transmission attenuator 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
value for V.17 modem:
0000 to 1111 ... counts up
6 for every -1dB 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0000: 0 dB
.
5 . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0
.
1111: -15 dB 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1
4

3 Undefined - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
FUNC 4 Bits 7 to 4:
The bit settings allow the user to program the modem transmission attenuation level. The smaller the
set value, the higher the transmission level becomes. If errors occur frequently or training is not sent,
the transmission level should be changed, as a rule.
Note:
The value from 0001 (-1dB) to 0111 (-7dB) is set as 8dB.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 22
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 6
2
1 0 1 1 1 1 1 1 1 1 1 1 1 1 0 0 1 1 5

1 1 1 0 0 0 1 1 1 1 1 1 0 1 1 1 1 0 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 23
09/02
FUNC 5
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Cable Equalizer: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
00: 0dB
01: -4dB
10: -8dB
6 11: -12dB 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

5 Echo Protect Tone to V.29: 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0


0: Not added
1: Added

4 Echo protection delay (300 1 0 0 0 1 0 0 0 0 0 0 0 1 0 1


bps):
0: No delay
1: Delay (500 ms)

3 Echo protection delay (High 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


speed):
0: No delay
1: Delay (500 ms)

2 Undefined - - - - - - - - - - - - - - -

1 Sending of CNG Signal at 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


Manual Transmission:
0: Do not send
1: Send

0 Sending of CED Signal at 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


Manual Reception:
0: Do not send
1: Send

<Remarks>
FUNC 5 Bits 7 and 6:
These bits program the equalizer value which has frequency characteristics. For long-distance commu-
nication, a larger equalizer value is recommended as a rule.

FUNC 5 Bit 5:
This bit selects whether or not the echo protect tone is added before the training for V.29 (9600 bps)
communication. By adding the echo protect tone, the echo cancel circuit of the satellite line is started up
to improve the line status.

FUNC 5 Bit 4:
This bit selects whether or not a delay (500 ms) is inserted before sending the signal at reversing trans-
mission/reception change and the timing is shifted to avoid line echo.
When the echo preventing circuit or echo cancel circuit causes missing of the beginning of the signal,
for example, in overseas communications where a delay may be larger, this bit should be set to 1 (on).

FUNC 5 Bit 3:
This bit selects whether or not a delay (500 ms) is inserted before the high-speed signal is sent to shift
the timing. Explanation for bit 4 is applicable.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 24
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

1 1 0 1 1 1 0 0 0 0 0 0 0 0 1 0 0 1 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

- - - - - - - - - - - - - - - - - - 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

FUNC 5 Bit 1:
This bit selects whether or not the CNG signal is output in manual transmission (on-hook dialing/off-
hook dialing). When the receiving terminal uses a switching device, CNG signal output is required
(1=on).

FUNC 5 Bit 0:
This bit selects whether or not the CED signal is transmitted in manual reception.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 25
09/02
FUNC 6
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Initial value of the commu- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


nication speed designated
by DIS/DCS
signal:
0000: 2400 bps
0001: 14400 bps (V.17)
6 0010: Undefined 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0011: Undefined
0100: 4800 bps
0101: 12000 bps (V.17)
0110: Undefined
5 0111: Undefined 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
1000: 9600 bps
1001: 9600 bps (V.17)
1011: Undefined
4 1100: 7200 bps 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1101: 7200 bps (V.17)
1110: Undefined
1111: Undefined

3 Threshold of image error: 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0


00: 5%
01: 10%
2 10: 15% 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1
11: 25%
1 Monitor Type: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0: BT Monitor
1: Protocol Monitor

0 Undefined - - - - - - - - - - - - - - -

<Remarks>
FUNC 6 Bits 7 to 4:
These bits set the modem speed. The speed should be programmed when the telephone line quality is
poor.

FUNC 6 Bits 3 and 2:


These bits set a threshold value to judge image quality. To make the criteria stringent, 00 (5%) should
be selected. When the threshold value is exceeded, RTN will be initiated.

FUNC 6 Bit 1:
This bit selects the monitor type when the line monitor function is turned on. When this bit is set to 0
(BEFORE TRANSMISSION MONITOR), monitoring stops on receiving DIS. When this bit is set to 1
(PROTOCOL MONITOR), monitoring is performed during communication, like forced line monitor.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 26
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

2
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3

1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 27
09/02
FUNC 7
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 CI-ON Determine Time: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


00: 175 ms
01: 125 ms
10: 800 ms
6 11: 145 ms 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

5 CI-OFF Determine Time: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


00: 500 ms
01: 350 ms
10: 175 ms
4 11: 90 ms 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

3 Undefined - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
FUNC 7 Bit 7 and 6:
These bits program call signal ON time. When CI cannot be received, the value should be changed.

FUNC 7 Bits 5 and 4:


These bits program call signal OFF time.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 28
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 29
09/02
FUNC 8
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Long Original mode: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0: Disable
1: Enable

6 Page Re-transmission at 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
receiving Negative Answer:
0: Not re-transmit
1: Transmit

5 Page-mismatch Display 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Indication:
0: Not displayed
1: Displayed

4 Undefined - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 High speed carrier-OFF 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


detection time
0: 1.5 sec
1: 6.0 sec (FTZ)

0 Undefined - - - - - - - - - - - - - - -

<Remarks>
FUNC 8 Bit 7:
This bit determines whether or not Long original function is available.
This setting links to the user function setting.

FUNC 8 Bit 6:
This setting is performed to avoid double transmission due to memory retransmission. When this bit is
set to 0 (off), the machine does not perform retransmission and proceeds to next page transmission.
During retries, the machine starts transmission of the next page.

FUNC 8 Bit 5:
This setting performs error indications if the number of pages do not match.

FUNC 8 Bit 1:
Sets the time to determine the carrier signal is stopped completely.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 30
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 31
09/02
FUNC 9
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 Speaker volume for all error 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


tone:
000: Level 0 (off)
001: Level 1
1 010: Level 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
011: Level 3
100: Level 4
101: Level 5
0 110: Level 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
111: Level 7 (maximum)

<Remarks>
FUNC 9 Bits 2 to 0:
Allows the user to adjust the volume level of the speaker when an error occurs.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 32
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5
2
- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 33
09/02
FUNC 10
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Transmission Report after a 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1


Direct Document Transmis-
sion:
00: Do not print
01: Undefined
6 10: Always print 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1
11: Print (re-sending of
error pages is OK)

5 Transmission Report Out- 1 1 1 0 1 1 1 1 1 1 1 1 0 1 1


put after Memory Transmis-
sion:
000: Not print
001: Undefined
010: Always output
4 011: Print (when completed 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
due to communication
error.)
100: Undefined
101: Undefined
110: Always print (with sent
3 document) 1 0 0 0 0 1 0 0 0 0 0 0 0 0 1
111: Print (when completed
due to communication error
+ with sent document)

2 Transmission Report Out- 1 1 1 0 1 1 1 1 1 1 1 1 0 1 1


put after Multi-address
Transmission:
000: Do not print
001: Do not print
010: Always print
1 011: Print (when completed 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
due to communication
error)
100: Undefined
101: Undefined
110: Always print (with sent
0 document) 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1
111: Print (when completed
due to communication error
+ with sent document)

<Remarks>
FUNC 10 Bits 7 and 6:
Allows the use to choose how and when a transmission report is printed.
This setting links to the user function setting.

FUNC 10 Bits 5 to 3:
These bits program whether or not the memory transmission report is output. These bits also select out-
put conditions. Allows the user to choose whether or not (and when) a transmission report is printed
when transmission is through memory.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 34
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

2
1 1 0 1 1 1 0 0 0 0 0 0 0 0 1 1 0 1 6

1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

1 1 0 1 1 1 0 0 0 0 0 0 0 0 1 1 0 1 3

1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 0 1 1 1 0 0 0 0 0 0 0 0 1 1 0 1 0

FUNC 10 Bits 2 to 0:
These bits program whether or not the broadcast transmission report is printed and the conditions for
printing.
This setting links to the user function setting.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 35
09/02
FUNC 11
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 Midnight and Noon time 1 1 0 1 1 0 1 1 1 1 1 1 1 1 1


setting:
0: 00:00
1: 12:00

4 Print report after a Multi- 1 1 0 1 1 0 1 1 0 1 1 1 1 1 1


polling:
00: Do not print
01: Do not print
10: Always print
3 11: Print (when completed 1 0 0 0 0 0 0 0 0 1 0 0 0 0 1
due to communication
error.)

2 Undefined

<Remarks>
FUNC11 Bit 5 :
It selects whether the clock indication at noon and midnight is 00:00 or 12:00 when the 12-hour system
is adopted.
When 0 is selected for this bit, the clock indication is from 00:00 to 11:59. When 1 is selected, the clock
indication is from 12:00 to 11:59.
When the 24-hour system is adopted, the clock indication is always from 00:00 to 23:59.

FUNC 11 Bits 4 and 3:


These bits program whether or not the multi polling transmission report is printed or not and the condi-
tions for printing.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 36
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5
2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

1 0 0 1 1 1 0 0 0 0 0 0 0 0 1 1 0 1 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 37
09/02
FUNC 12
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 Report print at user cancel: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0: Do not print
1: Print

<Remarks>
FUNC 12 Bit 0:
Determines if transmission result report is printed if the user cancels the job.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 38
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5
2
- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 39
09/02
FUNC 13
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 Mailbox Reception List 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


(Local Input):
0: Do not print
1: Print

5 Mailbox Reception List 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0


(Remote Input):
0: Do not print
1: Print

4 Automatic print of Journal: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


0: Do not print
1: Print

3 Recording contents when 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


Journal is output manually:
00: Transmissions only
01: Receptions only
2 10, 11:Transmissions/ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Receptions

1 NG Handling on Journal 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Status:
0: Do not print
1: Print

0 Undefined - - - - - - - - - - - - - - -

<Remarks>
FUNC 13 Bit 6:
It determines whether or not the reception list is printed when a mail box option is chosen at own termi-
nal.
This setting links to the user function setting.

FUNC 13 Bit 5:
It determines whether or not the acceptance list is print when a mail box information is received.
This setting links to the user function setting.

FUNC 13 Bit 4:
Selection determines whether or not the journal is printed automatically.
This setting links to the user function setting.

FUNC 13 Bits 3 and 2:


These selections determine whether or not the journal is printed manually, and select items to be
recorded (transmission, reception or transmission/reception).
This setting links to the user function setting.

FUNC 13 Bit 1:
Selections determine whether or not OK or NG (failed) is added as a communication result on the jour-
nal.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 40
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 41
09/02
FUNC 14
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 CI Signal Detect Count until 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


Auto Receive:
0000 to 1111 ... counts up
on every 1 time
6 0000: 1 time 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0001: 1 time
0010: 2 times
5 . 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1
.
4 . 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0
1111: 15 times

3 Speaker Volume of On- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


hook and Protocol Monitor:
000: Level 0 (off)
001: Level 1
2 010: Level 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
011: Level 3
100: Level 4
101: Level 5
1 110: Level 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
111: Level 7 (maximum)

0 Undefined - - - - - - - - - - - - - - -

<Remarks>
FUNC 14 Bits 7 to 4:
Selections set the CI counter value until the machine enters automatic reception mode.
This setting links to the user function setting.

FUNC 14 Bits 3 to 1:
Selections set speaker volume for the on-hook status or protocol monitor.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 42
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 2

1 1 1 0 0 0 1 1 1 1 1 1 1 1 1 1 1 0 5

0 1 0 1 1 1 0 0 0 0 0 0 0 0 0 0 0 1 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 43
09/02
FUNC 15
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Discard length of docu- 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0


ment paper:
00: No discard (0 mm)
01: Discard 13 mm
6 10: Discard 17 mm 1 1 1 1 1 1 1 1 1 1 0 1 1 1 1
11: Discard 34 mm

5 Vertical reduction on 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
recording paper:
0: Prohibited
1: Allowed

4 Undefined - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 Discard setting of record- 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1


ing paper:
0: OFF
1: ON

1 Maximum reduction rate in 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


vertical reduction:
0: 90%
1: 73%

0 Undefined - - - - - - - - - - - - - - -

<Remarks>
FUNC 15 Bits 7 and 6:
Selections determine how much to discard (on the recording paper) when the received data is too long
and exceeds the effective record length.

FUNC 15 Bit 5:
The selection determines whether or not data is reduced in vertical direction.

FUNC 15 Bit 2:
Set whether or not the received documents are recording with the discarded portion (Specified by Bits 7
and 6).
This setting links to the user function setting.

FUNC 15 Bit 1:
This bit programs maximum reduction rate in the vertical direction. This bit should be set to 1 (on) when
legal size document is reduced and printed on the A4 paper.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 44
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 0 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 45
09/02
FUNC 16
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Adding RTI: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0: Not added
1: Add

6 Adding TTI: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
0: Not added
1: Add

5 Undefined - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
FUNC 16 Bit 7:
The setting determines whether or not receiving terminal data is printed on received document.
This setting links to the user function setting.

FUNC 16 Bit 6:
The setting determines whether or not transmitting terminal data is recorded on received document.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 46
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 47
09/02
FUNC 17
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 Memory Reception (Substi- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


tution Reception) Function:
0: Not available
1: Available

0 ECM Function (Error Cor- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


rection Mode):
0: Not available
1: Available

<Remarks>
FUNC 17 Bit 1:
The selections allows or disallows memory reception.
This setting links to the user function setting.

FUNC 17 Bit 0:
The selection makes ECM available or not available.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 48
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5
2
- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 49
09/02
FUNC 18
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Privileged Reception set- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


ting:
0: No
1: Yes

6 JBIG function: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
0: Disable
1: Enable

5 File Recovery Transmission 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


setting:
0: Not available
1: Available

4 Undefined - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 Department Code setting: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0: No
1: Yes

1 Undefined - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
FUNC 18 Bit 7:
This bit setting determines whether or not privileged reception is activated.
This setting links to the user function setting.

FUNC 18 Bit 6:
This bit determines whether or not JBIG function is enabled or disabled.

FUNC 18 Bit 5:
This bit setting determines whether or not file recovery is available.
This setting links to the user function setting.

FUNC 18 Bit 2:
This bit setting determines whether or not the department control function is available.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 50
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

- - - - - - - - - - - - - - - - - - 1
- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 51
09/02
FUNC 19
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Cover Sheet Setting and 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


Transmitting operations:
00: Prohibited
01: Allowed
6 10: Not used 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
11: Allowed (cover image)

5 Account Code Setting: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0: Prohibited
1: Allowed

4 Department code in trans- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


mit header:
0: Not added
1: Add

3 Undefined - - - - - - - - - - - - - - -

2 Secure Reception function: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0: Prohibited
1: Allowed

1 Beep setting at the end of 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


reception:
0: OFF
1: ON

0 Quick Polling Communica- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


tion:
0: Prohibited
1: Allowed

<Remarks>
FUNC 19 Bits 7 and 6:
This bit determines whether or not the cover sheet is transmitted together with the document.
This setting links to the user function setting.

FUNC 19 Bit 5:
This bit determines whether or not the account code is added.
This setting links to the user function setting.

FUNC 19 Bit 4:
This bit determines whether or not department code is recorded.

FUNC 19 Bit 2:
This bit determines whether or not security reception is performed.
This setting links to the user function setting.

FUNC 19 Bit 1:
This bit determines whether or not a beep is made when reception is finished.

FUNC 19 Bit 0:
This bits determines whether or not quick polling is carried out.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 52
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

- - - - - - - - - - - - - - - - - - 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 53
09/02
FUNC 20
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 Receive Mode Setting 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


Value:
0: TEL (manual receive
mode)
1: FAX (auto receive
mode)

2 TTI off setting operation for 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1


user:
0: Disable
1: Enable

1 Transmission report off set- 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1


ting operation for user:
0: Disable
1: Enable

0 Undefined - - - - - - - - - - - - - - -

<Remarks>
FUNC 20 Bit 3:
The selections allow for either auto (FAX) or manual (TEL) reception mode.
This setting links to the user function setting.

FUNC 20 Bit 2:
Enables or disables the Transmission Header print mode.

FUNC 20 Bit 1:
Enables or disables the Transmission Report print mode.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 54
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5
2
- - - - - - - - - - - - - - - - - - 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 55
09/02
FUNC 21
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Minimum counter of CI 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
detection:
0001 to 1111 ... counts up
for each time.
6 0000: 1 time 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0001: 1 time
0010: 2 times
5 . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
.
4 . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1111: 15 times

3 CI ring volume value: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


000: Level 0 (off)
001: Level 1
010: Level 2
2 011: Level 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
100: Level 4
101: Level 5
110: Level 6
1 111: Level 7 (maximum) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

0 Undefined - - - - - - - - - - - - - - -

<Remarks>
FUNC 21 Bits 7 to 4:
Minimum number of CI (Call-in) until connection with the remote party is established.
The minimum number of rings until automatic reception is initialized depends on this setting.

FUNC 21 Bits 3 to 1:
These bits determine the CI ring volume.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 56
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 2

0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 57
09/02
FUNC 22
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Maximum redial counter 1 1 1 0 1 1 1 1 0 1 1 1 1 1 1


setting:
0001 to 1110 ... counts up
for each time.
6 0000: No retry 1 0 1 0 0 1 0 1 0 1 1 1 1 1 1
0001: 1 time
0010: 2 times
5 . 1 1 1 1 0 1 0 0 1 1 0 1 1 1 1
.
4 1110: 14 times 0 1 0 1 1 0 1 0 1 0 0 0 0 0 0
1111: Undefined

3 Minimum redial counter set- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


ting:
0001 to 1110 ... counts up
for each time.
2 0000: No retry 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0001: 1 time
0010: 2 times
1 . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
.
0 1110: 14 times 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
1111: Undefine

<Remarks>
FUNC 22 Bits 7 to 4:
Sets the maximum number of redial attempts.

FUNC 22 Bits 3 to 0:
Sets the minimum number of redial attempts.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 58
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 0 1 1 0 1 1 1 1 1 1 1 1 1 0 1 1 7

1 1 1 1 1 0 1 0 0 0 1 1 1 0 1 0 1 1 6 2

1 1 0 1 1 0 1 1 1 0 0 1 1 0 1 1 0 1 5

0 0 1 0 0 1 0 0 0 0 0 0 0 1 0 0 0 0 4

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 59
09/02
FUNC 23
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Maximum redial interval 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


counter setting:
0001 to 1110 ... counts up
6 for each minute. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
0000: 1 minute
0001: 1 minute
5 0010: 2 minutes 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
.
4 . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1111: 15 minutes

3 Minimum redial interval 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


counter setting:
0001 to 1110 ... counts up
2 for each minute. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0000: 1 minute
0001: 1 minute
1 0010: 2 minutes 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
.
0 . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1111: 15 minutes

<Remarks>
FUNC 23 Bits 7 to 4:
Sets the maximum time intervals between redials.

FUNC 23 Bits 3 to 0:
Sets the minimum time intervals between redials repeating the statement over again.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 60
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 6
2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 4

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

0 0 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 61
09/02
FUNC 24
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Priority of recording items in 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0


Journal and TX report:
00: Telephone Number > ID
> Name
01: Name > Telephone
Number > ID
6 10: ID > Telephone Num- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
ber > Name
11: ID > Name > Telephone
Number

5 SUB/PWD/SEP Communi- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
cation:
0: Not available
1: Available

4 Scanned page when mem- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


ory overflows:
0: Delete
1: Send

3 Undefined - - - - - - - - - - - - - - -

2 Line monitor for user mode: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0: OFF
1: ON

1 Undefined - - - - - - - - - - - - - - -

0 Always monitoring the com- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


munication line:
0: Not monitored
1: Monitored

<Remarks>
FUNC 24 Bits 7 and 6:
Sets the order of information to be printed in the journal and TX report information.

FUNC 24 Bit 5:
Sets the availability or non-availability of SUB/PWD/SEP communication.

FUNC 24 Bit 4:
It selects whether the transmission is canceled or data stored in memory is transmitted if the memory
becomes full during the transmission after storing data into memory.
This setting links to the user function setting.

FUNC 24 Bit 2:
This bit programs whether or not the transmission communication section programmed with FUNC 6 Bit
1 is monitored.
This setting links to the user function setting.

FUNC 24 Bit 0:
Sets the unit to monitor or not monitor the communication line.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 62
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

2
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

- - - - - - - - - - - - - - - - - - 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

- - - - - - - - - - - - - - - - - - 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 63
09/02
FUNC 25
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Facsimile Separator Page 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


Setting:
0: OFF
1: ON

6 Undefined - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 Letter Head Paper: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


000: OFF
001: Cassette 1
010: Cassette 2
1 011: Cassette 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
100: Cassette 4
111: Bypass
0 101-110: Undefined 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

<Remarks>
FUNC 25 Bit 7:
Facsimile Separator Page is a sheet automatically inserted between each received fax.
This setting links to the user function setting.

FUNC 25 Bits 2 to 0:
These bits select the Letter Head Paper Tray Option.

FUNC 26
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 64
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

2
- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 65
09/02
FUNC 27
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 Transmission time on same 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


speed:
00: 4 times
01: 3 times
4 10: 2 times 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
11: 1 time

3 Reception time on same 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


speed (V.34 only):
00: 4 times
01: 3 times
2 10: 2 times 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
11: 1 time
1 Use of V.34 Modem: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
0: Prohibited
1: Allowed

0 V.34 Modem Initial Speed: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


0: 28,800 bps
1: 33,600 bps

<Remarks>
FUNC 27 Bits 5 and 4:
Sets the number of times the unit attempts transmission of a page at the same transmission speed in
ECM mode.

FUNC 27 Bits 3 and 2:


Sets the number of times the unit attempts reception of a page at the same reception speed of the V.34.

FUNC 27 Bit 1:
Bit setting allows the user to use or not use the V.34 modem.

FUNC 27 Bit 0:
Bit setting allows the user to choose the speed at which the V.34 modem operates.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 66
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5
2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 67
09/02
FUNC 28
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Transmission attenuator 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
value for V.34 modem:
Counted up in the range
from 0000 to 1111, in units
of -1 dB.
6 0000 to 1111 ... counts up 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
for every -1dB.
0000: 0 dB
0001: -1 dB
0010: -2 dB
5 . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0
1001: -9 dB
4 . 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1111: -15 dB

3 Undefined - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
FUNC 28 Bits 7 to 4:
The bit settings allow the user to program the modem transmission attenuation level. The smaller the
set value, the higher the transmission level becomes. If errors occur frequently or training is not sent,
the transmission level should be changed, as a rule.
Note:
The value from 0001 (-1dB) to 0111 (-7dB) is set as 8dB.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 68
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

2
0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 6

1 0 1 1 1 1 1 1 1 1 1 1 1 1 0 0 1 1 5

1 1 1 0 0 0 1 1 1 1 1 1 0 1 1 1 1 0 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 69
09/02
FUNC 29
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Date format of clock: 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1


000: MM-DD-YY
001: DD-MM-YY
010: YY-MM-DD
6 011: MM-DD-YYYY 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0
100: Undefined
101: DD-MM-YYYY
110: YYYY-MM-DD
5 111: Undefined 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

4 Month format of clock: 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0: Numeric
1: Alphabets

3 Time display of clock: 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0: 24-hour system
1: 12-hour system (AM/PM)

2 Undefined - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
FUNC 29 Bits 7 and 5:
Bit settings allow the user to choose the format for displaying the date.
This setting links to the user function setting.

FUNC 29 Bit 4:
Bit setting allows the Date Format to be set for either Alphabet or numeric.
This setting links to the user function setting.

FUNC 29 Bit 3:
Bit setting allows the user to choose between the 24-hour or the 12-hour system.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 70
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 0 1 0 1 1 1 1 1 1 1 1 1 1 1 0 7

0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 6 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 4

0 0 0 1 0 1 0 0 0 0 0 0 0 0 0 0 0 1 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 71
09/02
FUNC 30
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Energy saving mode 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


switching
00: Sleep Mode
01: Super Sleep Mode
6 10 - 11: Undefined 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

5 Auto Shut Off Mode timer 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


setting (Auto Sleep Mode)
000000: 3 min.
000001: 5 min.
000010: 10 min.
4 000011: 15 min. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
000100: 20 min.
000101: 25 min.
000110: 30 min.
000111: 35 min.
3 001000: 40 min. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
001001: 45 min.
001010: 50 min.
001011: 55 min.
2 001100: 60 min. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
001101: 70 min.
001110: 80 min.
001111: 90 min.
010000: 100 min.
1 010001: 110 min. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
010010: 120 min.
010011: 150 min.
010100: 180 min.
010101: 210 min.
0 010110: 240 min. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
010111: 1 min.
011000 - 111111: Undefined

<Remarks>
FUNC 30 Bits 7 and 6:
Sets the Energy saving mode.
This setting links to the user function setting.

FUNC 30 Bits 5 and 0:


Sets the time until the Super Sleep Mode or Sleep Mode is entered.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 72
09/05
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 73
09/05
FUNC 31
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Print report after a ITU-T 1 1 1 0 1 1 1 1 1 1 1 1 0 1 1


relay transmission (Origina-
tor):
00X: Do not print
6 010: Always 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
011: On error
110: Always (with send doc-
ument)
5 111: On error (with send 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0
document)

4 Print report after a ITU-T 1 1 1 0 1 1 1 1 1 1 1 1 0 1 1


relay transmission (Relay
Station):
00X: Do not print
3 010: Always 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
011: On error
110: Always (with send doc-
ument)
2 111: On error (with send 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0
document)

1 ITU-T Relay Station Recep- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


tion List:
0: Do not print
1: Print

0 Undefined - - - - - - - - - - - - - - -

<Remarks>
FUNC 31 Bits 7 to 5:
These bits program whether or not the relay transmission report is printed and the conditions for print-
ing.
This setting links to the user function setting.

FUNC 31 Bits 4 to 2:
These bits program whether or not the relay broadcast transmission report is printed and the conditions
for printing.
This setting links to the user function setting.

FUNC 31 Bit 1:
Determines whether the relay reception list is printed, and the conditions for printing.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 74
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2

0 1 0 1 1 1 0 0 0 0 0 0 0 0 0 0 0 1 5

1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

0 1 0 1 1 1 0 0 0 0 0 0 0 0 0 0 0 1 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 75
09/02
FUNC 32
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Print report after a Relay 1 1 1 0 1 1 1 1 1 1 1 1 0 1 1


Transmission (End Station):
00X: Do not print
010: Always
6 011: On error 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
110: Always (with send doc-
ument)
111: On error (with send
5 document) 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0

4 A5 Size Transmission 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Report print after a Direct
Document Transmission:
0: Do not Print
1: Print

3 A5 Size Transmission 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Report print after a Memory
Transmission:
0: Do not Print
1: Print

2 Undefined - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
FUNC 32 Bits 7 to 5:
These bits select whether or not the transmission report at the end station is transmitted to the origina-
tor by the relay station.
This setting links to the user function setting.

FUNC 32 Bit 4:
This bit select whether or not the Direct Transmission Report is print on A5 size paper.

FUNC 32 Bit 3:
This bit select whether or not the Memory Transmission Report is print on A5 size paper.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 76
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2

0 1 0 1 1 1 0 0 0 0 0 0 0 0 0 0 0 1 5

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 77
09/02
FUNC 33
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Speaker volume for Key 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


touch tone:
6 000: OFF 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
100: ON
5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

4 Languages in LCD display 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


and report:
00000: English
00001: Italian
00010: Germany
3 00011: Spanish 0 0 0 0 0 1 1 0 0 0 0 0 1 0 0
00100: Br Portuguese
00101: Dutch
00110: Swedish
00111: Finnish
2 01000: Norwegian 0 0 0 0 1 0 0 0 1 1 0 0 0 0 0
01001: Portuguese
01010: Danish
01011: French
1 01100: Ca French 0 1 0 0 1 0 1 1 1 0 1 0 0 1 0
01101: Japanese
01110: Czech
01111: Polish
0 10000: Rumanian 0 0 0 1 0 0 0 0 1 1 0 0 1 1 0
10001: Hungarian
10010: Greek

<Remarks>
FUNC 33 Bits 7 to 5:
Allows the user to adjust the Key Touch Tone volume.
This setting links to the user function setting.

FUNC 33 Bits 4 to 0:
These bits select the language for messages and list indication.
This setting links to the user function setting.

FUNC 34
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 78
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5
2
0 0 0 0 0 0 1 1 0 1 0 0 0 0 1 1 1 1 4

0 0 1 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 3

0 0 0 0 0 0 0 1 1 0 1 0 0 0 0 1 0 1 2

0 0 1 0 0 0 1 1 1 0 1 0 0 0 1 0 0 1 1

0 0 1 0 0 0 0 0 1 1 0 0 0 0 1 0 0 1 0

Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 79
09/02
FUNC 35
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Receive Interval Setting: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0000 to 1111 counts up for
each minute.
0000: 0 minute (=OFF)
6 0001: 1 minute 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0010: 2 minutes
.
5 . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
.
4 1110: 14 minutes 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1111: 15 minutes

3 Undefined - - - - - - - - - - - - - - -

2 Weekly timer 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0: Off
1: On

1 Auto supplies order number 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


0: 1 order
1: 2 order

0 Ext. field bit comm. Func- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


tion
0: comm
1: comm Err.

<Remarks>
FUNC 35 Bits 7 to 4:
This function insures, there will be a period of time set aside receiving incoming facsimiles during peri-
ods of heavy outgoing transmission activity. After every fourth consecutive transmission, this machine
will wait incoming facsimiles to be received.
This setting links to the user function setting.

FUNC 35 Bit 2:
Select enabling/disabling timer setup for days of the week.
This setting links to the user function setting.

FUNC 35 Bit 1:
Select the number of sets for supplies order. (0: 1 set, 1: 2 sets)

FUNC 35 Bit 0:
0: When the extended bit is on for the DIS or DTC signal and there is no subsequent bit information, the
communication is enabled, regarding the sequence up to the extend bit as valid.
1: When the extended bit is on for the DIS or DTC signal and there is no subsequent bit information, the
communication error will result.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 80
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

- - - - - - - - - - - - - - - - - - 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 81
09/02
FUNC 36
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

FUNC 37
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 Isometric magnification RX 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
smoothing function (Rota-
tion)
0: Prohibited
1: Allowed

0 Isometric magnification RX 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
smoothing function (No
rotation)
0: Prohibited
1: Allowed

<Remarks>
FUNC 37 Bits 1:
Set the smoothing function to whether it is to be used or not, when printing the isometric magnification
RX after rotation.

FUNC 37 Bit 0:
Set the smoothing function to whether it is to be used or not, when printing the isometric magnification
RX after no rotation.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 82
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5
2
- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 83
09/02
FUNC 38
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

FUNC 39
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 84
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5
2
- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 85
09/02
[B] PC FUNC 0-7
The settings here are PC functions, which are divided into 8 tables. Each table has functions of 8 Bits.
By entering 0 or 1 in each Bit, its function can be set. The following are details of each table.

PC FUNC 0
Bit Contents Default

7 Use of PC Interface: 1
0: Use prohibited
1: Use allowed

6 Send the Receive Documents to PC: 0


PC transfer method at reception
00: No transfer
01: SUB-Address (Only when transferred from the sender)
5 10: All documents 0
11: Undefined

4 Undefined -

3 Communication Log Management: 0


Informing of communication journal to PC print
0: Do not inform
1: Inform

2 LDC Function: 1
0: Prohibited
1: Allowed

1 Printing Function: 1
0: Prohibited
1: Allowed
0 Scanner Function: 1
0: Prohibited
1: Allowed

<Remarks>
PC FUNC 0 Bit 7:
This switch allows or prohibits use of the PC interface.

PC FUNC 0 Bits 6 and 5:


If 00 is selected, the data is not sent to the PC. If SUB Address is selected, the data is sent to the PC
only when the sub address is received from the transmitting party. If All documents is selected, all
received data are sent to the PC.

PC FUNC 0 Bit 3:
This bit selects whether or not the journal is sent to the PC.

PC FUNC 0 Bit 2:
This switch allows or prohibits any entry or dialing from the PC.
Used in conjunction with PC interface software.

PC FUNC 0 Bit 1:
This switch allows or prohibits any entry from the PC.

PC FUNC 0 Bit 0:
This switch allows or prohibits scanning directed from the PC.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 86
09/02
PC FUNC 1
Bit Contents Default

7 Undefined -

6 -

5 -

4 Print Rx document after sending to PC: 0


0: Off
2
1: On

3 Permanent retry to send the RX data: 0


0: Off
1: On

2 Undefined -

1 -

0 -

<Remarks>
PC FUNC 1 Bit 4:
This bit function is print RX document, after the transmission RX data to PC.

PC FUNC 1 Bit 3:
This bit selects whether or not to continue to transfer the received file until the number of retries set as
the transfer retry counter is reached, when the FAX failed to transfer the received file to a PC at PC FAX
reception.

PC FUNC 2
Bit Contents Default

7 Undefined -

6 -

5 -

4 -

3 -

2 -

1 -

0 -

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 87
09/02
PC FUNC 3
Bit Contents Default

7 Retry Counter value at PC transfer: 0


0000 to 1111 ... counts up for each retry.
0000: No retry
6 0001: 1 retry 1
0010: 2 retries
.
5 . 0
1111: 15 retries
4 1

3 Retry interval for PC transfer: 0


0001 to 1111 ... counts up for each minute.
0000: default (2 minutes)
2 0001: 1 minute 0
0010: 2 minutes
.
1 . 1
1111: 15 minutes
0 0

<Remarks>
PC FUNC 3 Bits 7 to 4:
This switch specifies the number of retries for data transmission to the PC.

PC FUNC 3 Bits 3 to 0:
This switch specifies the time intervals between retries in data transmission to the PC.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 88
09/02
PC FUNC 4
Bit Contents Default

7 Retry counter for STAT message to PC: 0


0000: No retry
6 0001: 1 retry 1
.
5 . 0
. 1
4 2
1111: 15 retrys

3 Time between retry attempts for STAT message: 0


0000: default (2 minutes)
2 0001: 1 minute 0
.
1 . 1
.
0 0
1111: 15 minutes

<Remarks>
PC FUNC 4 Bits 7 to 4:
Set the number of retries to notify the PC of fax status information via PC interface.

PC FUNC 4 Bits 3 to 0:
Set the intervals of retries to notify the PC of fax status information via PC interface.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 89
09/02
PC FUNC 5
Bit Contents Default

7 RX cover open 0
0: Off
1: On

6 Printer Error 0
0: Off
1: On

5 Print jam 0
0: Off
1: On
4 No process unit 0
0: Off
1: On

3 Heater Error 0
0: Off
1: On
2 Process unit near end 0
0: Off
1: On

1 Process unit end 0


0: Off
1: On

0 Toner near end 0


0: Off
1: On

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 90
09/02
<Remarks>
PC FUNC 5 Bit 7:
Set the function to notify the PC, via PC interface, that the RX cover (Front cover, Side cover, ADU
cover) is open.

PC FUNC 5 Bit 6:
Set the function to notify the PC, via PC interface, that a printer error has occurred.

PC FUNC 5 Bit 5: 2
Set the function to notify the PC, via PC interface, that a printer jam has occurred.

PC FUNC 5 Bit 4:
Set the function to notify the PC, via PC interface, that the process unit is not attached.

PC FUNC 5 Bit 3:
Set the function to notify the PC, via PC interface, that a heater error has occurred.

PC FUNC 5 Bit 2:
Set the function to notify the PC, via PC interface, that the replacement of the process unit is soon
required.

PC FUNC 5 Bit 1:
Set the function to notify the PC, via PC interface, that the replacement of the process unit is required.

PC FUNC 5 Bit 0:
Set the function to notify the PC, via PC interface, that the replacement of the toner cartridge is soon
required.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 91
PC FUNC 6
Bit Contents Default

7 Toner end 0
0: Off
1: On

6 Power on 0
0: Off
1: On

5 Memory over 0
0: Off
1: On
4 TX cover open 0
0: Off
1: On

3 Scan paper exist 0


0: Off
1: On
2 No cassette 0
0: Off
1: On

1 No paper 0
0: Off
1: On

0 Paper detect on bypass cassette 0


0: Off
1: On

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 92
09/02
<Remarks>
PC FUNC 6 Bit 7:
Set the function to notify the PC, via PC interface, that the toner has run out, via PC interface.

PC FUNC 6 Bit 6:
Set the function to notify the PC, via PC interface, that the power is turned on, via PC interface.

PC FUNC 6 Bit 5:
Set the function to notify the PC, via PC interface, that a memory full state has occurred. 2

PC FUNC 6 Bit 4:
Set the function to notify the PC, via PC interface, that the TX cover (ADF cover or Jam access cover
(excluding the platen cover)) is open.

PC FUNC 6 Bit 3:
Set the function to notify the PC, via PC interface, that the paper detection sensor has detected the
original.

PC FUNC 6 Bit 2:
Set the function to notify the PC, via PC interface, that no paper cassette exists.

PC FUNC 6 Bit 1:
Set the function to notify the PC, via PC interface, that no paper is loaded.

PC FUNC 6 Bit 0:
Set the function to notify the PC, via PC interface, that paper is loaded on the stack feed bypass.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 93
PC FUNC 7
Bit Contents Default

7 Undefined -

6 -

5 -

4 -

3 -

2 -

1 -

0 -

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 94
09/02
[C] HOME 0-2

HOME 0
Bit Contents Default

7 Undefined -

6 -

5 -
2
4 -

3 -

2 -

1 -

0 -

HOME 1
Bit Contents Default

7 Undefined -

6 -

5 -

4 -

3 -

2 -

1 -

0 -

HOME 2
Bit Contents Default

7 Undefined -

6 -

5 -

4 -

3 -

2 -

1 -

0 -

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 95
09/02
[D] UAD 0-19
The following settings are special functions relating to telephone specifications for each country/region.
The functions are divided into 20 tables. Each table has functions of 8 Bits. By entering 1 or 0 in each
Bit, its function are set.

UAD 0
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Range of dial tone fre- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


quency (PSTN):
000: 300Hz to 600Hz
001: 300Hz to 650Hz
6 010: 390Hz to 550Hz 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
011: 400Hz to 450Hz
100: 350Hz to 480Hz
101: 300Hz to 500Hz
5 110: Reserved 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
111: Reserved

4 Detection time to recognize 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


as dial tone (PSTN):
000: 2 sec.
001: 800 msec.
3 010: 400 msec. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
011: 1 sec.
100: 1.3 sec.
101: 1.8 sec.
2 110: 2.5 sec. 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1
111: 500 msec.

1 Allowable gap during line 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


current detection (PSTN):
00: Off
01: 50 msec.
0 10: 100 msec. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
11: 200 msec.

<Remarks>
UAD 0 Bits 7 to 5:
Sets the range of the dial tone frequency that should be detected when calling directly to a PSTN.

UAD 0 Bits 4 to 2:
Sets the time when the dial tone is recognized when calling directly to a PSTN. When a dial tone is con-
tinuously detected for the time specified, the facsimile regards the line as being connected.

UAD 0 Bits 1 and 0:


Sets the allowable gap during line current detection when calling directly to a PSTN. In line current
detection, even if there are gaps within the time specified in this setting, the counter is not reset and
continues to count the duration of line current detection after the current is re-detected.
When BZT is selected for DTC/LCC for PSTN in UAD 1, this setting is ignored.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 96
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR 2
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

0 0 0 1 1 1 0 0 0 0 0 0 1 0 1 0 0 1 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 97
09/02
UAD 1
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Allowable gap during dial 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


tone detection (PSTN):
00: Off
01: 70 msec.
6 10: 160 msec. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
11: 240 msec.

5 Method to detect dial tone 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


and line current (PSTN):
000: BZT (DTC/LCC)
001: LCC 5 sec.
4 010: DTC only 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
011: Undefined
100: DTC (USA)
101: LCC 3 sec.
3 110: Undefined 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
111: No Check

2 Maximum waiting time for 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


dial tone (PSTN):
000: 20 sec.
001: 10 sec.
1 010: 8 sec. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
011: 15 sec.
100: 3.3 sec.
101: Undefined
0 110: Undefined 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
111: Undefined

<Remarks>
UAD 1 Bits 7 and 6:
Sets the allowable gap during dial tome detection when calling directly to a PSTN. In dial tone detec-
tion, even if there are gaps within the time specified in this setting, the counter is not reset and contin-
ues to count the duration of dial tone detection after the dial tone whose frequency is in the specified
range is re-detected.

UAD 1 Bits 5 to 3:
Sets the method to detect the dial tone and line current when calling directly to a PSTN.
BZT (DTC/LCC) Performs German BZT type of detection
LCC 5 sec. Only 5 sec. Line current is detection
DTC only Only dial tone is detected.
DTC (USA) Only dial tone is detected. Duration of detected tone until it is regarded as the
dial tone is fixed 3.3 msec. Even if no dial tone is detected, dialing will be started.
LCC 3 sec. 3 second line current detection is performed.
No check Neither dial tone nor line current is detected.

UAD 1 Bits 2 to 0:
Sets the maximum waiting time for dial tone detection when calling directly to a PSTN. If the dial tone is
not detected and redial attempt or internal retry will be performed later.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 98
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 99
09/02
UAD 2
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Range of dial tone fre- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


quency (PABX):
000: 300Hz to 600Hz
001: 300Hz to 650Hz
6 010: 390Hz to 550Hz 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
011: 400Hz to 450Hz
100: 350Hz to 480Hz
101: 300Hz to 500Hz
5 110: Reserved 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
111: Reserved

4 Detection time to recognize 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


as dial tone (PABX):
000: 2 sec.
001: 800 msec.
3 010: 400 msec. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
011: 1 sec.
100: 1.3 sec.
101: 1.8 sec.
2 110: 2.5 sec. 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1
111: 150 msec.

1 Allowable gap during line 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


current detection (PABX):
00: Off
01: 50 msec.
0 10: 100 msec. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
11: 200 msec.

<Remarks>
UAD 2 Bits 7 to 5:
Sets the range of the dial tone frequency that should be detected when calling through a PABX.

UAD 2 Bits 4 to 2:
Sets the time when the dial tone is recognized when calling through a PABX. When a dial tone is contin-
uously detected for the time specified in this setting, the facsimile regards the line as being connected.

UAD 2 Bits 1 and 0:


Set the allowable gap during line current detection when calling through a PABX. In line current detec-
tion, even if there are gaps within the time specified in this setting, the counter is not reset and contin-
ues to count the duration of line current detection after the current is re-detected.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 100
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

0 0 0 1 1 1 0 0 0 0 0 0 1 0 1 0 0 1 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 101
09/02
UAD 3
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Allowable gap during dial 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


tone detection (PABX):
00: Off
01: 70 msec.
6 10: 160 msec. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
11: 240 msec.

5 Method to detect dial tone 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


and line current (PABX):
000: BZT (DTC/LCC)
001: LCC 5 sec.
4 010: DTC only 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
011: Undefined
100: DTC (USA)
101: LCC 3 sec.
3 110: Undefined 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
111: No Check

2 Maximum waiting time for 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


dial tone (PABX):
000: 20 sec.
001: 10 sec.
1 010: 8 sec. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
011: 15 sec.
100: 3.3 sec.
101: Undefined
0 110: Undefined 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
111: Undefined

<Remarks>
UAD 3 Bits 7 and 6:
Sets the allowable gap during dial tome detection when calling through a PABX. In dial tone detection,
even if there are gaps within the time specified in this setting, the counter is not reset and continues to
count the duration of dial tone detection after the dial tone whose frequency is in the specified range is
re-detected.

UAD 3 Bits 5 to 3:
Sets the method to detect the dial tone and line current when calling through a PABX.
BZT (DTC/LCC) Performs German BZT type of detection
LCC 5 sec. Only 5 sec. Line current is detection
DTC only Only dial tone is detected.
DTC (USA) Only dial tone is detected. Duration of detected tone until it is regarded as the
dial tone is fixed 3.3 msec. Even if no dial tone is detected, dialing will be started.
LCC 3 sec. 3 second line current detection is performed.
No check Neither dial tone nor line current is detedted.

UAD 3 Bits 2 to 0:
Sets the maximum waiting time for dial tone detection when calling through a PABX. If the dial tone is
not detected and redial attempt or internal retry will be performed later.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 102
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 103
09/02
UAD 4
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Busy tone frequency range: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


000: 300Hz to 600Hz
001: 350Hz to 550Hz
010: 300Hz to 500Hz
6 011: 300Hz to 700Hz 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
100: Reserved
101: Reserved
110: Reserved
5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
111: Reserved

4 Busy tone before dialing: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0: No check
1: Check

3 Busy tone after dialing: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


0: No check
1: Check

2 Dial T1 timer: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
000: 60 sec.
001: 35 sec.
010: 90 sec.
1 011: 55 sec. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
100: 145 sec.
101: Undefined
110: Undefined
0 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1
111: Undefined

<Remarks>
UAD 4 Bits 7 to 5:
Sets the range where a busy tone frequency is detected.

UAD 4 Bit 4:
Set whether a busy tone is detected before dialing as well as the dial tone and line current.

UAD 4 Bit 3:
Set whether a busy tone is detected after dialing as well as the dial tone and line current.

UAD 4 Bits 2 to 0:
Sets the value of the T1 timer in the calling terminal.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 104
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 105
09/02
UAD 5
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 USCC #12: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
0: Enable
1: Disable

6 Undefined - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
UAD 5 Bit 7:
If T1 time-out (no response from remote) occurs continuously 12 time in automatic dialing, all of the pro-
grammed calling jobs are cleared.
The counter is reset when an effective signal is detected.
The number of T1 time-out in automatic dialing is counted (manual dialing not included).

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 106
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

- - - - - - - - - - - - - - - - - - 6 2
- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 107
09/02
UAD 6
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Type of dial pulse: 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0


00: Normal
01: Shift
6 10: Reverse 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0
11: Undefined

5 Undefined 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

4 Internal retry setting: 0 1 1 0 0 1 1 0 0 0 1 0 0 0 0


0: Disable
1: Enable

3 Dial Retry Counter: 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0


0000 to 1110 ... counts up
for each time.
0000: No redialing
2 0001: 1 time 0 0 1 0 1 0 1 1 0 1 0 0 0 0 1
0010: 2 times
0011: 3 times
.
1 . 0 1 0 1 0 0 0 0 1 0 0 1 1 1 0
.
0 1110: 14 times 1 1 0 1 1 1 0 1 1 1 1 1 1 1
0
1111: Reserved

<Remarks>
UAD 6 Bits 7 and 6 :
Sets the type of dial pulse sent when each dial number is dialed.
Shift Reverse
Dial Key Normal
(n+1) (10-n)
1 1 2 9
2 2 3 8
3 3 4 7
4 4 5 6
5 5 6 5
6 6 7 4
7 7 8 3
8 8 9 2
9 9 10 11
0 10 1 10

UAD 6 Bit 4:
Sets whether internal retries are performed. Internal Retry is the dialing attempt performed when line
connection cannot be established due to a line current or dial tone not being detected before dialing.
Internal retries are not counted as redial attempts.

UAD 6 Bits 3 to 0:
These bits program the number of redial times.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 108
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6
2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3

1 0 1 1 1 0 1 1 0 0 0 0 1 0 1 0 0 0 2

0 1 0 0 0 0 0 0 1 1 1 1 0 1 0 1 1 0 1

1 0 1 1 1 1 0 0 1 1 1 1 0 1 1 0 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 109
09/02
UAD 7
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Alternate time when a 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1


pause is set as part of a dial
number:
000: None (0 sec.)
001: 1 sec.
6 010: 2 sec. 0 1 1 1 1 1 1 0 1 0 1 1 0 1 0
011: 4 sec.
100: 3.3 sec.
101: 10 sec.
5 110: Undefined 0 0 0 1 0 0 0 0 0 0 0 0 1 0 0
111: Undefined

4 Undefined - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

<Remarks>
UAD 7 Bits 7 to 5:
These bits programs the switch time when a pause is entered as a part of a dial number.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 110
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 0 1 1 1 1 1 1 1 1 1 0 0 1 1 1 1 7

2
0 0 1 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 6

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 111
09/02
UAD 8
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Inter-digit pause setting: 1 0 1 1 1 1 1 1 0 1 1 1 1 0 0


00: 900 msec.
01: 550 msec.
6 10: 700 msec 1 0 1 1 0 0 0 1 0 0 1 0 0 1 0
11: 800 msec.

5 Single pause setting: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


0: Disable
1: Enable

4 Undefined - - - - - - - - - - - - - - -

3 Interval between redialing 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


attempts:
0001 to 1111 ... counts up
2 for each minute. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0000: default (3 minutes)
0001: 1 minute
1 0010: 2 minutes 0 1 1 1 1 1 1 1 1 1 1 1 1 1 0
.
0 . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
.
1111: 15 minutes

<Remarks>
UAD 8 Bits 7 and 6:
Sets the pause time that is put between dial digits in pause dialing.

UAD 8 Bit 5:
When Enable is selected, only the first pause is effective and others are ignored even if the pause key
is pressed more than once in dialing to one destination.

UAD 8 Bits 3 to 0:
These bits program the redial intervals.
This setting links to the user function setting.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 112
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 0 1 1 1 1 1 1 0 0 0 1 1 0 0 0 1 7

1 1 0 1 1 1 1 1 1 0 0 0 1 1 0 0 0 1 6
2
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

- - - - - - - - - - - - - - - - - - 4

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

1 1 1 0 0 0 1 1 1 1 1 1 1 1 0 1 1 0 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 113
09/02
UAD 9
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Equalizer Value at MF Dial- 0 1 1 0 0 0 0 0 0 0 0 0 0 0 0


ing:
00: 0 dB
01: -4 dB
6 10: -8 dB 0 0 0 0 1 1 1 1 1 1 0 0 0 0 0
11: -12 dB

5 DP Make/Break: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1
000: 60/40 msec. (10 PPS)
001: 67/33 msec. (10 PPS)
010: 63/37 msec. (10 PPS)
4 011: 50/50 msec. (10 PPS) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
100: 67/33 msec. (20 PPS)
101: for TW (33.3%)
110: Undefined
3 0 0 1 0 0 0 1 0 0 0 0 1 1 1 1
111: Undefined

2 MF Timing: 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0
000: 80/80 msec.
001: 70/70 msec.
010: 70/150 msec.
1 011: 60/60 msec. 0 0 0 0 0 0 1 0 0 0 0 0 0 1 1
100: 80/100 msec.
101: 150/50 msec.
110: 150/240 msec.
0 0 0 0 0 1 0 0 0 0 1 0 1 0 0 0
111: Undefined

<Remarks>
UAD 9 Bits 7 and 6:
These bits program the equalizer value for the MF signal.

UAD 9 Bits 5 to 3:
Sets the make time and brake time during pulse dialing.

UAD 9 Bits 2 to 0:
Sets the tone on and tone off times for tone dialing (MF).

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 114
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 0 0 0 0 0 0 1 0 0 0 1 1 0 0 1 0 0 7

0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 6 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 5

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

1 1 1 0 0 0 0 1 1 0 0 1 1 1 1 1 0 0 3

0 0 0 1 1 1 1 0 1 0 0 1 1 0 0 1 0 1 2

0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 1

0 0 0 0 0 0 0 0 0 1 1 0 0 1 0 0 1 0 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 115
09/02
UAD 10
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Dial tone reception attenua- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


tion (PSTN):
000: -24dB
001: -27dB
010: -30dB
6 011: -33dB 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
100: -36dB
101: -39dB
110: -42dB
5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
111: -45dB

4 Undefined - - - - - - - - - - - - - - -

3 Attenuator Value at MF 0 1 1 1 1 1 1 1 1 1 1 1 1 1 0
Dialing:
0000 to 0100: -4dB
0101: -5dB
2 0110: -6dB 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1
0111: -7dB
1000: -8dB
1 . 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1
.
0 . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1111: -15 dB

<Remarks>
UAD 10 Bits 7 to 5:
Sets the dial tones attenuation detection level during reception (PSTN).

UAD 10 Bits 3 to 0:
These bits program the attenuator value for the MF signal.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 116
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

- - - - - - - - - - - - - - - - - - 4

1 1 1 0 0 0 1 1 1 1 1 1 1 1 0 0 1 0 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 2

0 0 0 1 1 1 0 0 0 0 0 0 0 0 1 1 0 1 1

1 0 1 1 1 1 1 1 0 0 0 0 1 1 1 0 0 1 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 117
09/02
UAD 11
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

UAD 12
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

UAD 13
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 118
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5
2
- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 119
09/02
UAD 14
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 Dial tone reception attenua- 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


tion (PABX):
000: -24dB
001: -27dB
2 010: -30dB 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
011: -33dB
100: -36dB
101: -39dB
1 110: -42dB 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
111: -45dB

0 Undefined - - - - - - - - - - - - - - -

<Remarks>
UAD 14 Bits 3 to 1:
Sets the dial tones attenuation detection level during reception (PABX).

UAD 15
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 120
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5
2
- - - - - - - - - - - - - - - - - - 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

- - - - - - - - - - - - - - - - - - 0

Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 121
09/02
UAD 16
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Busy Tone ON Determine 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


Time:
000: 80 to 650 msec.
001: 450 to 550 msec.
6 010: 200 to 650 msec. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
011: 400 to 600 msec.
100: 120 to 550 msec.
101: 420 to 610 msec.
5 110: Reserved 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
111: Reserved

4 Busy Tone OFF Determine 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0


Time:
000: 80 to 650 msec.
001: 450 to 550 msec.
3 010: 200 to 650 msec. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
011: 400 to 600 msec.
100: 160 to 600 msec.
101: 170 to 700 msec.
2 110: 380 to 630 msec. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
111: 150 to 470 msec.

1 Undefined - - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - - -

<Remarks>
UAD 16 Bits 7 to 5:
These bits program busy tone signal ON time.

UAD 16 Bits 4 to 2:
These bits program busy tone signal OFF time.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 122
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 123
09/02
UAD 17
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

UAD 18
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

UAD 19
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Undefined - - - - - - - - - - - - - - -

6 - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 - - - - - - - - - - - - - - -

3 - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 124
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5
2
- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

- - - - - - - - - - - - - - - - - - 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

- - - - - - - - - - - - - - - - - - 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 125
09/02
[E] EX TYPE
The settings here are the Exchange functions. This table has functions of 8 Bits. By entering 0 or 1 in
each Bit sets, its function. The following is details of this Table.

EX TYPE 1
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 Exchange Type: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0: PSTN
1: PABX

6 Undefined - - - - - - - - - - - - - - -

5 - - - - - - - - - - - - - - -

4 Dial Type: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
0: DP
1: MF

3 PABX Access for Local line: 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


00: No Setting
01: Not Used
10: Access Digit
2 11: Flash 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

1 Flash timing: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
00: 80 ms
01: 100 ms
10: 270 ms
0 11: Undefind 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

<Remarks>
EX TYPE 1 Bit 7:
This bit sets the Exchange Type (PSTN/PABX).
This setting links to the user function setting.

EX TYPE 1 Bit 4:
This bit sets the dialing method (DP/MF).
This setting links to the user function setting.

EX TYPE 1 Bit 3-2:


It determines the way of calling when the exchange type is PABX and the first digit of the telephone
number is *.
This setting links to the user function setting.

EX TYPE 1 Bit 1-0:


It determines the way of calling when the exchange type is PABX and the first digit of the telephone
number is #.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 126
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR
2
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7

- - - - - - - - - - - - - - - - - - 6

- - - - - - - - - - - - - - - - - - 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 127
09/02
[F] ACC DGT1-2
The settings here are Access Digit functions, which are divided into 2 tables. Each table has functions
of 8 Bits. By entering 0 or 1 in each Bit, its function can be set. The following are details of each table.

ACC DGT 1
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 1st Digit (Local Use) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

6 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

3 2nd Digit (Distant Use) 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

ACC DGT 2
Default
Bit Contents
US DE GB IT SE NO DK CH FI NL AT BE PT ES SG

7 3rd Digit (Local & Distant 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1


Use)
6 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

3 Undefined - - - - - - - - - - - - - - -

2 - - - - - - - - - - - - - - -

1 - - - - - - - - - - - - - - -

0 - - - - - - - - - - - - - - -

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 128
09/02
Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR
2
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

Default
Bit
HK AU FR LA(110V) LA(220V) CA GR RU PL HU CZ TR ZA IE CN TW RO KR

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 6

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 5

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4

- - - - - - - - - - - - - - - - - - 3

- - - - - - - - - - - - - - - - - - 2

- - - - - - - - - - - - - - - - - - 1

- - - - - - - - - - - - - - - - - - 0

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 129
09/02
[ 3 ] MEMORY WRITE
You can refer to and change the data stored at each address in the SRAM and DRAM.
ADDRESS and DATA input it with hex data.

<Key used in operation> <Display messages>

USER FUNCTION Press the


USER FUNCTION key

Enter SERVICE MODE

05.TEST MODE Select menu

ENTER

05.MAINTENANCE Select test menu

ENTER

03.MEMORY WRITE Use or keys

CANCEL ENTER

Input ADDRESS Hex data entry method

ENTER

Input DATA

ENTER

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 130
[ 4 ] ERROR COUNTER SHIFT
The actual information in the error count list is usually automatically moved to the history side every
1000 communications unless error counter shift is performed. Therefore, this is used to move the infor-
mation to the history side before reaching 1000 communications. When error count shift is performed,
the count values on the actual side of the error count list are moved to the history side and the values
on the CURRENT COUNTER side are initialized. The information having been moved to the history
side is added to the previous values.

<Key used in operation> <Display messages> 2

USER FUNCTION Press the


USER FUNCTION key

Enter SERVICE MODE

05.TEST MODE Select menu

ENTER

05.MAINTENANCE Select test menu

ENTER

04.ERR COUNTER SHIFT Use or keys

CANCEL ENTER

Select YES Use or keys

ENTER

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 131
[ 5 ] PIX MEMORY TRANSFER
When the original(s) received cannot be printed out because of printer trouble, etc., this function is used
to transfer the data in pix memory to the specified location. When you select PIX MEMORY TRANS-
FER and specify a destination, the data in pix memory will be transferred to the specified destination.

<Key used in operation> <Display messages>

USER FUNCTION Press the


USER FUNCTION key

Enter SERVICE MODE

05.TEST MODE Select menu

ENTER

05.MAINTENANCE Select test menu

ENTER

05.PIX MEMORY TRANSFER Use or keys

ENTER

Input FAX number Use or keys

Send data in memory

Note:
To specify a transfer destination, you can enter the abbreviated number or press the one-touch
key as well as the direct entry of the telephone number.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 132
2.3.3 SERVICE LIST
This function allows you to print lists. There are six kinds of lists that can be printed.
PROTOCOL TRACE *1
TOTAL ERRORS *1
FUNCTION (FUNC 05, 08 List)
DRUM HISTORY
MEMORY DUMP LIST
FUNCTION (Jam counter, ROM ver.) 2
* 1: To be printed when the FAX Kit (GD-1220/1221) is installed.

<Key used in operation> <Display messages>

USER FUNCTION Press the


USER FUNCTION key

Enter SERVICE MODE

05.TEST MODE Select menu

ENTER

06.SERVICE LIST Select test menu

ENTER

Select list to be printed Use or keys

ENTER

Print list

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 133
08/08
[ 1 ] PROTOCOL TRACE
This list is printed out with a title of PROTOCOL TRACE LIST. The result of the last communication job
just before the list is printed out is printed out. You can check the communication protocol with this
result.

Print Items
TIME The time when signal transmission is begun or the time when signal reception is begun
is printed in minutes : seconds.
SEND/RCV The send signal is printed as S, and the receive signal as R. Also, the high-speed
tracing signal is printed as TCF, and the high-speed image signal as PIX.
FCF DATA Facsimile control field. The FCF command is printed.
FIF DATA When there is an information field, its contents are printed in either HEX, BIN or TEL
format.
ASCII FIF is converted to ASCII code and printed.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 134
[ 2 ] TOTAL ERRORS
This list is printed out with a title of ERROR COUNT LIST. It indicates the history of errors to check for
errors attributable to the line conditions.

Print Items
TRANSMISSION/RECEPTION Indicates whether the error is on the sending side or on the receiving
side.
STATUS HISTORY Prints the error codes in the ascending order.
Prints the history of errors moved from the CORRENT COUNTER side
2
by occurred error count / communication count.
The time when moved to the history side is printed in the time print field
(top line).
CURRENT COUNTER Prints the present error occurred status by occurred error count / com-
munication count. The time when counting is started is printed in the
time print field (top line). When the communication count reaches 1000
on the CURRENT COUNTER side, the error occurred status is auto-
matically moved to and added to the history side and the CURRENT
COUNTER side is cleared.
Even if the communication count has not reached 1000, if error counter
shift is executed, the counts up to the present will be moved from the
CURRENT COUNTER side to the history side.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 135
[ 3 ] FUNCTION (FUNC, 05, 08 List)
This list is printed out with a title of SETTING REPORT FOR MAINTENANCE. It prints a list of present
function settings.

Print Items
1st Sheet
COUNTRY/REGION Country/Region code
FUNC 0 to 39 Prints the settings at this point of time in binary format.
PC FUNC 0 to 7
HOME 0 to 2
UAD 0 to 19
EX TYPE 1
ACC DGT 1 to 2
2nd Sheet
05 xxx Prints the set values at this point of time.
08 xxx
(xxx is code number.)

[ 4 ] DRUM HISTORY
Refer to 2.2.9 SERVICE LIST in the Service Handbook (e-STUDIO165/167/205/207/237).

[ 5 ] MEMORY DUMP
Refer to 2.2.9 SERVICE LIST in the Service Handbook (e-STUDIO165/167/205/207/237).

[ 6 ] FUNCTION LIST
Refer to 2.2.9 SERVICE LIST in the Service Handbook (e-STUDIO165/167/205/207/237).

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 136
07/02
2.3.4 Country/Region code

<Key used in operation> <Display messages>

0 2 Power ON

2
Code No.
Cancel

ENTER
CLEAR/STOP or ( FC used to correct value)
START

Warming up

Country/Region Code Country/Region Code


United States US 1 Ireland IE 353
Canada CA 9999 Singapore/Saudi Arabia SG/SA 65
Germany DE 49 Hong Kong HK 852
United Kingdom GB 44 Australia/New Zealand AU/NZ 61
Italy IT 39 France FR 33
Sweden SE 46 Latin America (LT) LA1 55
Norway NO 47 Latin America (A4) LA2 9998
Denmark DK 45 Russia RU 7
Switzerland CH 41 Poland PL 48
Finland FI 358 Hungary HU 36
Netherlands NL 31 Czech Republic CZ 42
Austria AT 43 Turkey TR 90
Belgium BE 32 South Africa ZA 27
Portugal PT 351 Taiwan TW 886
Spain ES 34 China CN 86
Greece GR 30

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 137
2.3.5 Printer Unit Adjustment
Adjust each item of the printer unit in the FAX mode, using the grid pattern of the test print.

Adjustment Procedure
Follow the procedure below to adjust each item of the printer unit.
1) Print the FUNCTION LIST to confirm and record the margin values.
2) Set 0 for margin values 430 to 433 in 05: Adjustment mode.
3) Adjust each value of 05-403 and 404.
Adjustment items:
05-1300-0 Main scan magnification in the FAX mode (16 x 15.4)
05-1300-1 Main scan magnification in FAX mode (15.4 x 16)
4) Change the margin values (05-430, 431, 432 and 433) to the values printed in the FUNCTION LIST.

Note:
The adjustment should be made after setting 0 for the margin values (05-430, 431, 432 and 433).
Be sure to change the values to the original ones.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 138
[ 1 ] Adjustment of main scan magnification in the FAX mode (16 x 15.4)

(1) Make a test print and adjustment as in the following procedure.

[1][3] [2][1][2] [1]


02.PRINT TEST [ENTER] [ENTER]
[POWER] (Code) (Cassette)

[ENTER]
[START] [CLEAR/STOP] 2
(Test print) (Print end)

(2) Measure distances A and B in the printed grid pattern. Both distances are from the 2nd to12th
lines.

12

Print movement direction


A

B
2 12

(3) Make adjustment so that A and B will be in the following ranges.


A: 147.6 mm 1%
B: 153.4 mm 1%

[0][5] [1][3][0][0] [0]


[ENTER] [ENTER] Make a test print (212).
[POWER] (Code) (Sub code)

Notes:
1. An increase in the value makes A shorter and makes B longer (0.126%/step).
2. The adjustment value is effective within the range from 98 to 158.
The default adjustment value is 128.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


SELF-DIAGNOSIS MODE
2 - 139
[ 2 ] Adjustment of main scan magnification in the FAX mode (15.4 x 16)

(1) Make a test print and adjustment as in the following procedure.

[1][3] [2][1][3] [1]


02.PRINT TEST [ENTER] [ENTER]
[POWER] (Code) (Cassette)

[START] [CLEAR/STOP]
[ENTER]
(Test print) (Print end)

(2) Measure distances D and E of the printed grid pattern. Both distances are from the 2nd to
12th lines.

12

Print movement direction


D

E
2 12

(3) Make adjustment so that D and E will be in the following ranges.


D: 153.4 mm 1%
E: 147.6 mm 1%

[0][5] [1][3][0][0] [1]


[ENTER] [ENTER] Make a test print (213).
[POWER] (Code) (Sub code)

Notes:
1. An increase in the value makes D shorter and makes E longer (0.121%/step).
2. The adjustment value is effective within the range from 98 to 158.
The default adjustment value is 128.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


SELF-DIAGNOSIS MODE
2 - 140
3. TROUBLESHOOTING

3.1 Diagnosis Over Telephone


Most problems end users inquire are the results of the following. Therefore, ask the nature of the trou-
ble (in detail) first to seek the cause. These questions can lead to a speedy resolution of the trouble
without the need for a service technician.

Simple misoperation
A trouble caused by a simple misoperation can be solved by the user alone with an appropriate
instruction through the telephone.

A failure with the telephone line


The machines condition can be checked by the users operating sending/receiving documents to/ 3
from another FAX unit.

A failure with the other partys machine


The other partys machines condition can be checked by the users operating sending/receiving
documents from/to the users machine.

Also, by verifying the error message in the LCD display or the error code on the Journal with the user,
the nature of the trouble can be confirmed. This information is important in finding the cause of trouble.
Whenever it can be obtained from the user, respond on the telephone by tracing the P. 3-3 "3.3
Flow Chart for Recommended Telephone Screening". This will help the service technician to be pre-
pared for the necessary service requirements.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


TROUBLESHOOTING
3-1
3.2 Recommend Flow Chart for Field Service

Call from customer

Trouble solved Service technician does not


Telephone screening
need to be dispatched

Not solved

Dispatch a service technician


(Field service)

Not solved

Assistance by phone for the field

service technician from the remote


diagnosis center

Field service

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


TROUBLESHOOTING
3-2
3.3 Flow Chart for Recommended Telephone Screening

START

Turn ON the power with


no recording paper or
document

3
NO Is the AC NO
Is ADD PAPER dis-
power cable properly Plug it in properly
played on the LCD?
plugged in?

YES YES

Set the recording paper Dispatch a service


technician

NO Is the NO
Is a communication
recording paper set Set it correctly
journal printed out?
correctly?

YES YES

Set a document Dispatch a service


technician

Is original copied NO NO
correctly by Is the document set
Set it correctly
pressing [START]? correctly?

YES YE S

Dispatch a service
technician
1

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


TROUBLESHOOTING
3-3
1

YES NO
Any problem with Using specified Use the specified
the copied image? recording paper? recording paper

NO YES
Dispatch a service
technician

Any problem with the NO


2
auto-dialing function?

YES

Is
COMMUNICATION NO Dispatch a service
ERROR displayed on technician
the LCD?

YES

Select the correct dial


Is the dial type NO
type (DP/PB) in the
correct?
Function Mode

YES

Is inapplicable
RJ11C connector YES Connect the applicable
connected to the circuit connector
(TEL/LINE)?

NO

Is the phone number NO Correct the phone


correct? number

YES

Dispatch a service
technician

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


TROUBLESHOOTING
3-4
2

Any problem with NO


3
the transmission?

YES

Is Transmission is not
NO
the receiving side using a possible if the receiving side 3
is using
G3 machine? G2 or MF machine

YES

Check the error


code and dispatch a
service technician

Any problem with


the reception?
YES

Is the automatic
reception possible in the NO
Dispatch a service technician
Auto-Reception Mode?

YES

Is the
manual reception NO
possible in the Manual Dispatch a service technician
Reception Mode?

YES

Check noise on the telephone


Is the received NO circuit or any defect of the Dispatch a service
other equipment. Perform
document normal? the communication technician
interference test

YES

END

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


TROUBLESHOOTING
3-5
3.4 Error Analysis Flow

3.4.1 Self-Diagnosis function


Service technicians can figure out the contents of the error with the following information:
1) Display on the LCD panel
2) Error code on the transmission/reception journal

3.4.2 Precautions for diagnosis


Service technicians should output the Dial List and Function List before using the self-diagnosis mode.
Confirm that the amount of memory left is 100% before turning the power OFF and then check the fol-
lowing items.
Check if the power cable is properly plugged in.
Check if the connectors are securely connected.
Pay full attention to an electric shock at the power section and a short circuit of the conductor pattern
on the board when servicing with the power cable connected to the outlet while the cover is taken
off.
Make sure that there is not any connector remains disconnected or loosened screw after the error
analysis.
Make sure that the machine operates properly with a communication test every time the error analy-
sis has been performed.

Notes:
Before replacing the parts, confirm that there is no data to be transmitted or no received doc-
ument in the memory. Turn OFF the power and unplug the power cable.
Do not touch the terminal of the connectors. Otherwise, a poor connection may be caused.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


TROUBLESHOOTING
3-6
3.5 Fault Analysis

3.5.1 Power-ON is not possible


1) Check if the power cable is plugged into an appropriate outlet (of the correct voltage).

2) Check if the rated voltages are being output from the PS-ACC. When the measured voltage is not
the rated value, replace the PS-ACC.

3) Check if each connector between the HPNL board (CN271) and the MAIN board (CN7) is discon-
nected.

4) Check if each connector between the MAIN board (CN3) and the PS-ACC (CN104) is disconnected.
3
5) Check if each connector pin is removed or the harness is broken.

6) Check if any conductor pattern on the switching power supply, and MAIN board is open- or shortcir-
cuited.

7) Replace the HPNL board.

8) Replace the MAIN board.

3.5.2 Original transport error


Check the error code and refer to the TROUBLESHOOTING of Service Handbook for the equipment.

3.5.3 Recording paper transport error


Check the error code and refer to the TROUBLESHOOTING of Service Handbook for the equipment.

3.5.4 Image trouble


Check the image and refer to the TROUBLESHOOTING of Service Handbook for the equipment.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


TROUBLESHOOTING
3-7
3.5.5 Communication error
Communication errors may occur when the condition of a particular phone circuit happens to be bad at
the time of attempting the communication job. Therefore, do the communication over again. If commu-
nication errors occur too many times, prepare another (operational) FAX unit and check the communi-
cation condition among the three FAX units, thus analyzing the troubles.

A communication error occurs between A and B.

This FAX Remote FAX unit

Operational FAX

1) If normal communications are possible between A and C, and the communication trouble occurs B
and C, it can be assumed that FAX B is malfunctioning.

2) If normal communications are possible between B and C, and the communication trouble occurs A
and C, it can be assumed that FAX A is malfunctioning. Therefore, adjust the transmission attenua-
tor value (FUNC4, 28) and the cable equalizer value (FUNC5).

3) If normal communications are possible between A and C and between B and C, it can be assumed
that there is a problem in the line between A and B.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


TROUBLESHOOTING
3-8
3.6 Lists Required at Problem in the Field
Output the following lists when problem occurs in the field. They are described in the order of the prior-
ity the most important one come first in this section. It is not necessary to output these lists immediately
after the trouble has occurred, but they must be prepared for any kind of trouble regarding the FAX
operation.

[Precaution]
Disconnect the telephone line to stop the communication when trouble occurs. Since the only
last communication is reported on the protocol trace list, if the telephone line is not discon-
nected immediately after the trouble has occurred, next communication might come in before
the line is disconnected and be printed out instead of the communication in question.
Do not turn OFF the power before printing the protocol trace list and memory dump list.
Otherwise, the information will be lost.
3

Item
List
No.

1 Protocol trace list

2 Error count list

3 Function List for Maintenance

4 Memory dump list

Note:
Enter the HEX address and the size referring to the following table.
Character to be entered Key to press

0 0

1 1

2 2

. .
. .
. .

9 9
A *0

B *1

C *2

D *3

E *4

F *5

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


TROUBLESHOOTING
3-9
1) Protocol trace list
FAX protocols for one communication to which an error has occurred are reported.

2) Error count list


The FAX communication error history: Frequency of the occurrence of a particular error can be
checked.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


TROUBLESHOOTING
3 - 10
3) Function List for Maintenance
This report lists the set statuses of various functions that can be programmed by service personnel.

4) Memory dump list (System)


Command/status information between the CPU controlled by the FAX board and the CPU of the
equipment is reported.

5) Memory dump list (FAX)


Command/status information between the CPU controlled by the FAX board and the CPU of the
equipment is reported.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


TROUBLESHOOTING
3 - 11
6) Transmission journal
Transmission records for 150 communications are listed. Occurrence conditions of the communica-
tion errors can be checked with information such as the time when the communication took place,
error codes, etc. Error code 50 indicates that the other partys line of the other side is busy (talk-
ing). If this error occurs frequently, it can be decreased somewhat by increasing the number of redi-
aling attempts. Also, it can be checked if the communication fails with a particular address.

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


TROUBLESHOOTING
3 - 12
7) Reception journal
Reception records for 150 communications are listed. Occurrence conditions of the communication
errors can be checked with the information such as the time when the communication took place,
error codes, etc. Also, it can be checked if the communication fails with a particular address.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


TROUBLESHOOTING
3 - 13
8) Function List
This list prints out the set statuses of various functions which have been programmed by the user.

Symptoms (describe as specific as possible)

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


TROUBLESHOOTING
3 - 14
3.7 Other Information Required for Error Analysis
The following information is also needed to analyze the malfunction (especially a communication error).
Check the circles below if they are applicable.

1) If the error is cleared or not.


- Cleared by turning ON/OFF the power.

2) Frequency of occurrence
- Frequently (occurring daily or always)
- Sometimes (about once a week)
- Only once

3) When a communication error is occurring, turn ON the circuit monitor for the line, and check the con-
dition of the FAX communication with the tone from the speaker.
3

Note:
Turn OFF the circuit monitoring function after the checking is finished.
- Signals from the transmitter and that from the receiver clash.
Check the model name of the other partys machine.
- Noise occurring on the circuit.
Ask the telephone (or telecommunications) company if the line condition is normal.
- Busy tone is heard from the other party during the communication.
Ask by phone if the other partys machine has any problem. If it does not, check its model
name.
- Others (describe condition):______________________________________________________

4) Condition of the machine when the problem occurred


- State of the machine
Availability of the recording paper:
1st drawer (size = ) No paper Paper present
2nd drawer (size = ) No paper Paper present
3rd drawer (size = ) Not installed No paper Paper present LCF
4th drawer (size = ) Not installed No paper Paper present LCF

- Conditions of ADF or RADF (this information is needed for transmission error)


Originals have been all exited
Abnormal (original jam, etc.)
Others (be as specific as possible):

- Condition/State of the communication


Transmission error

Reception error

ECM mode

G3 mode
Image errors such as stream image or interrupted image occur in the G3 mode when the noise
occurs on the line. These are liable to occur since the line condition differs depending on each
communication.
If the same errors occur to the image which was resent, they can be decreased by reducing the
transmission speed of the sending side.

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


TROUBLESHOOTING
3 - 15
Communication cannot be made with a particular number.
(Information of the other sides machine: _______________________________)
If the communication is impossible with a particular number, it is considered that the other partys
machine has broken down or has been busy (there is no response) because the recording paper
has run out and the memory is full. Check the condition of the terminal of the other side.
If there is no problem with the terminal, check the model name since there is a possibility that
particular type of the machine has caused the problem.

Original size = A3 B4 A4 B5 A5
Size of the received document =A3 B4 A4 B5 A5
Resolution = NORMAL (8*3.85) FINE (8*7.7) U-FINE (16 or 8*15.4)
Error occurred to the _________st/nd/rd/th sheet out of ________sheets.

- Condition of the circuit connection


Connected directly with the public telephone circuit.

Connected via a local exchange device or the main equipment.


Is any other equipment connected besides this unit?
Does the ring tone sound normally (rings for 1 second and stops for 2 seconds)
(If it is not normal, the reception may not be started.)

Circuit switching device


Are the circuit settings (DP, PB) of the circuit switching device the same as those for this unit?

Configuration of the units


(Illustrate the units connected to your machine such as the telephone lines, exchange system, telephones,
modems, etc.)

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


TROUBLESHOOTING
3 - 16
4. PRECAUTIONS FOR INSTALLATION OF FAX UNIT
Be sure to perform the country/region setting and initialization described in the Unpacking Instruction.

4.1 Country/Region Setting

4.1.1 The FG harness on the NCU board


Connect the FG harness correctly to the connector on the NCU board according to the table below.

FG harness

W2
W1
4

Fig. 4-1

Country/Region FG Harness Country/Region FG Harness

US United States - SG Singapore W2

CA Canada - SA Saudi Arabia -

DE Germany W2 HK Hong Kong W2

GB United Kingdom W2 AU Australia W2

IT Italy W1 NZ New Zealand W2

SE Sweden W2 FR France W2

NO Norway W2 LA1 Latin America (LT) -

DK Denmark W1 LA2 Latin America (A4) -

CH Switzerland W2 RU Russia W2

FI Finland W1 PL Poland W2

NL Netherlands W2 HU Hungary W2

AT Austria W2 CZ Czech Republic W2

BE Belgium W2 TR Turkey W2

PT Portugal W2 ZA South Africa W2

ES Spain W2 TW Taiwan -

GR Greece W2 CN China W2

IE Ireland W2 RO Romania W2

KR Korea -

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


PRECAUTIONS FOR INSTALLATION OF FAX UNIT
4-1
07/02
4.1.2 Country/Region code
After the FAX unit has been installed, set the country/region code following the procedure below.

[Operation procedure]
1) Turn ON the power while pressing [0] and [2] simultaneously.
2) When COUNTRY/REGION= is displayed, enter the appropriate country/region code.
3) Press the [ENTER] key.

Country/Region Code Country/Region Code

US United States 1 SG Singapore 65

CA Canada 9999 SA Saudi Arabia 65

DE Germany 49 HK Hong Kong 852

GB United Kingdom 44 AU Australia 61

IT Italy 39 NZ New Zealand 61

SE Sweden 46 FR France 33

NO Norway 47 LA1 Latin America (LT) 55

DK Denmark 45 LA2 Latin America (A4) 9998

CH Switzerland 41 RU Russia 7

FI Finland 358 PL Poland 48

NL Netherlands 31 HU Hungary 36

AT Austria 43 CZ Czech Republic 42

BE Belgium 32 TR Turkey 90

PT Portugal 351 ZA South Africa 27

ES Spain 34 TW Taiwan 886

GR Greece 30 CN China 86

IE Ireland 353 RO Romania 40

KR Korea 82

GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved


PRECAUTIONS FOR INSTALLATION OF FAX UNIT
4-2
07/02
4.2 Initialization
After the country/region code has been set, initialize the FAX unit following the procedure of chapter
2.3.4 (P. 2-137).

2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved GD-1220/1221


PRECAUTIONS FOR INSTALLATION OF FAX UNIT
4-3
06/06
GD-1220/1221 2006 - 2009 TOSHIBA TEC CORPORATION All rights reserved
PRECAUTIONS FOR INSTALLATION OF FAX UNIT
4-4

You might also like