FT & FV Comparison - R2
FT & FV Comparison - R2
FT & FV Comparison - R2
A) Normal gravity system shall A) Booster system need to be A) As Flush Valve system requires
work. added to avail optimum design booster pump therefore Flush
Design pressure for Flush Valve to work. Tank system is economical.
2
Requirement
B) All downtakes are through B) Top 3 - 4 floors requires B) Booster shall require 24 X 7
gravity pressure booster pump and below floors power hence shall attract
supplied through gravity network. additional cost for running the
system.
A) Water will be stored in Flush A) Water is used directly from A) Flush Valve is recommended as
Tank which may damage flush network of pipes therefore no water can be used
Flushing Water tank due to chlorine contents damage to flush valve. instantaneously in Flush Valve.
4
related issues present in flush water.
B) Refering to STP vendor the B) As water is used directly from B) Flush Valve is recommended as
treated water can be stored for 3 network of pipe no issue of no storage is required.
- 4 days without any odour / stagnation of water subsequently Note: Water can be stored upto 4
damage to fittings / fixture. no odour OR damage to fittings / days by addition of chlorine ,
fixture. however the maintenance cost
will increase.