Powered by AI
The key takeaways are that the document provides information on Parker Hannifin Corporation's hydraulic cartridge systems products and warns the user of their responsibility in properly selecting and using the products. It also introduces their new catalog for these products.

The purpose of the document is to introduce Parker Hannifin Corporation's new catalog for their hydraulic cartridge systems products and warn users of their responsibility when selecting and using these products.

Parker Hannifin Corporation offers a wide range of products related to hydraulic systems including motors, pumps, power units, valves, controls, electronics, filtration products, cylinders, rotary actuators, accumulators, power take-off systems, and integrated hydraulic circuits.

Hydraulic Cartridge Systems

Threaded Cartridge Valves and Integrated


Hydraulic Products
Presenting...
We would like to take this e Complete Product
opportunity to welcome you to Offering Including:
the new Hydraulic Cartridge Check Valves
Systems catalog. Catalog HY15- Shuttle Valves
3502 represents our entire
Load/Motor Controls We at the Hydraulic Cartridge
published product offering.
This catalog is intended to Flow Controls Systems Division hope you find
replace all previous Hydraulic Pressure Controls this catalog useful and want to
Cartridge Systems (HCS) Logic Elements thank you for turning to Parker
catalogs. You will find many Directional Controls Hannifin for your integrated
changes to this catalog in Manual Valves hydraulic needs.
content and format. Here are Solenoid Valves
a few highlights of what you
Proportional Valves
will find:

WARNING - USER RESPONSIBILITY


FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation
by users having technical expertise.
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,
maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is
responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

OFFER OF SALE
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributor. This offer and its acceptance
are governed by the provisions stated in the detailed "Offer of Sale" elsewhere in this document.
Catalog HY15-3502/US Threaded Cartridge Valves and
Integrated Hydraulic Products

PLEASE READ
How to use this catalog...
Product Index Catalog HY15-3502/US
Contents

SERIES CAVITY DESCRIPTION


Check Valves

FLOW PRESSURE PAGE NO.


CV
LPM/GPM BAR/PSI

Valves
Check
Each product tab has its own product index for that particular STANDARD CHECKS
D1A060 ............ 2U ............... Check Valve Insert, Ball Type ......................... 145/38 ...... 420/6000 ...................... CV5 SH
D1B125 ............ 2C ............... Check Valve Insert, Ball Type ...................... 500/132 ...... 420/6000 ...................... CV6

section. Basic product specifications are shown along with catalog D0WB2 ............. CAV0W-2 .... Cartridge Check, Ball Type ............................. 3.5/0.9 ...... 420/6000 ...................... CV7

Shuttle
Valves
D02B2 .............. C08-2 .......... Cartridge Check, Ball Type ............................... 45/12 ...... 420/6000 ...................... CV8
CVH081P .......... C08-2 .......... Cartridge Check, Poppet Type ......................... 38/10 ...... 350/5000 ...................... CV9

page numbers and product symbols. Further detail can be found CVH103P .......... C10-2 .......... Cartridge Check, Poppet Type ......................... 60/16 ...... 350/5000 .................... CV10 LM

Load/Motor
D04B2 .............. C10-2 .......... Cartridge Check, Ball Type ............................. 160/42 ...... 420/6000 .................... CV11

Controls
CVH121P .......... C12-2 .......... Cartridge Check, Poppet Type ....................... 121/32 ...... 350/5000 .................... CV12
D06B2P ............ C16-2 .......... Cartridge Check, Poppet Type ....................... 280/74 ...... 420/6000 .................... CV13
on the specific catalog pages. CVH161P .......... C16-2 .......... Cartridge Check, Poppet Type ....................... 226/60
CVH201P .......... C20-2 .......... Cartridge Check, Poppet Type ....................... 303/80
...... 350/5000
...... 350/5000
.................... CV14
.................... CV15
FC

Controls
Flow
CVH104P .......... C10-2 .......... Cartridge Check, Poppet Type
.............................................. 2 to 1 Flow Path ................................................ 19/5 ...... 350/5000 .................... CV16
D06C2 .............. C16-2 .......... Cartridge Check, Poppet Type
.............................................. 2 to 1 Flow Path ......................................... 500/132

PILOT OPERATED CHECKS


CP084P ............ C08-3 ..........

Technical Tips CV
Catalog HY15-3502/US
Technical Tips

INTRODUCTION:
Check Valves

This technical tips section is designed to help familiarize you with the Parker line of Check Valves. In this section

Valves
At the beginning of each product section, we have a series of

Check
we present the products that are new to this catalog as well as some design features of our checks valves. In
addition, we present common options available to help you in selecting products for your application.
SH
Finally we give a brief synopsis of the operation and applications of the various product offered in this section.

Technical Tip pages. These pages describe, in detail, the

Shuttle
Valves
NEW PRODUCTS:

application and operational parameters of our cartridge valves. If LM There are several new additions and product improvements to our Check Valve product line.

Load/Motor
Controls
Here are just some of the general design features and advantages
to the Winners Circle check valve.
you have any application or specification questions that cannot be FC

Controls
Dual Sense Paths Spherical Poppets

answered by this section, please contact your local Parker

Flow
The dual sense paths reduce The spherical design allows for a
the pressure drop variations. more consistent seating regardless
of poppet alignment resulting in
PC lower leakage.

representative or give us a call.


Pressure
Controls

Product Pages Catalog HY15-3502/US


Technical Information

General Description
Check Valve
Series CVH103P
CV

The individual product catalog pages detail fully the product

Valves
Check
Cartridge Style Check Valve. For
additional information see Technical
Tips on pages CV1-CV4. SH

specifications and operating parameters of each valve. Additionally, Features

Shuttle
Valves
Spherical poppet for low leakage
D-Ring eliminates back-up rings

dimensional information, as well as a complete model code for Dual sense paths for reduced DP
LM

Load/Motor
Controls
All external parts zinc plated

ordering product is shown. Performance Curve


FC

Controls
Pressure Drop vs. Flow (Through cartridge only)

Flow
PC

Pressure
Controls
Dimensions Millimeters (Inches)

Coil and Body CV


Catalog HY15-3502/US
Technical Information

Features
Super Coil
Series 5/8 I.D.

Integral Deutsch connector coil exceeds IP69K

There are 2 sections in this catalog that assist you in selecting


Valves
Check

standards

SH
Integral Deutsch connector coil thermal shock dunk test
rated

the proper valve body or solenoid coil for your particular Integral Amp Jr. coil exceeds IP67 standards for thermal
Shuttle
Valves

shock, water resistance and dunk capability


Universal 50/60 Hz operation

application. Also, the cavity details are shown for all Parker LM Coil hermetically sealed, requires no O-rings or
Load/Motor

waterproofing kits
Controls

External plated steel flux-carrying band (unlike


encapsulated band) enables coil to withstand severe Ordering Information
and Sterling cavities currently in use. FC

thermal shocks without cracking
Symmetrical coil can be reversed without
affecting performance CA
Controls
Flow

Specifications Super Coil Wattage Voltage Termination


5/8 I.D.
PC Coil Type S Standard Code Wattage
P Puissant
Pressure

S Standard
Controls

Nominal Wattage S 18 Watts P Puissant


(See Ordering P 28 Watts
Code Voltage
Watts Amps Ohms**

Technical Data CV
Catalog HY15-3502/US
Technical Information

Valve/Cavity Compatibility Dimensions


Standard Bodies and Cavities
10 Size, 2-Way

Millimeters (Inches)

The Technical Data section outlines various hydraulic guidelines


Valves

For additional information see Technical


Check

Tips on pages BC1-BC6. -A-


18.08 (.712)
SH 17.83 (.702)
VALVE 2.92 (.115)

such as ratings, torques, limitations in use, seals, and hydraulic 7/8


2.54 (.100)
11.30 (.445)
Shuttle

Winners Circle
Valves

14UNF-2B .79 (.031) Max.


(.002) B Max.
1.59 (.062) R.
Waterman

fluid/filtration information. LM
Parker

CEC
FPS
Load/Motor

45
Controls

30
30.16 20.68 (.814) 15.47 (.609)
Winners Circle X X X X X (1.188) 20.57 (.810) Max.
63
CAVITY

Parker X X X
FC 15.93 (.627)
Waterman X X X 15 63 15.88 (.625)
Controls

FPS X X X 24.05 (.947) .25 (.010) R. (.001) A


23.93 (.942) Max.
Flow

CEC X X X -B-
16.00 (.630)
15.75 (.620)
23.93 (.942)
PC 23.67 (.932)
Performance Curve 33.32 (1.312) Min.
Pressure
Controls

Pressure Drop vs. Flow

III Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3502/US

Integrated Hydraulic Circuits


Parker is a recognized leader in integrated circuit design focusing on flexibility, innovation and
support. Application engineering and manufacturing support facilities are located throughout
North America, Europe, Scandinavia and in other areas around the world.
The Parker Hydraulic Cartridge Systems Applications Engineering team is thoroughly
experienced in all facets of hydraulic system design, particularly the integration of Parker
technologies that develop into complete manifold and sub-system solutions. We can assist in
the development of any circuit, be it a simple single cartridge, or a complex multi-station
assembly. We have the tools to engineer your success!

Application Engineering Assistance


Parker has many trained and experienced application Expert Machining
engineers who are focused on providing the best, most We have designated state-of-the-
cost efficient solution for your application requirements. Our art HMCs for the specific purpose
application specialists can provide you with of machining prototypes for quick
all the capabilities of Parkers Hydraulic customer demand. This is the basis
Cartridge Systems Division. Additionally, of the Parker Speed Shop.
our application engineers are trained
in all of Parkers products so an
application can be a one-
stop call.

Assembly and Test


Our production and assembly areas are
Manifold Design staffed with experienced and knowledgeable
Our advanced 3D Computer- people. We use automated testing
Aided Design and Computer-Aided processes to test even the most complicated
Manufacturing software enables fast assemblies.
and accurate design as well as rapid manufacturing
integration among our integrated circuit production
facilities.

Integrated Hydraulic Circuits advantage:


Reduce the number of fittings, hoses and couplings
Optimize and reduce components used
Allow fewer leakage points
Consume less space
Provide simplified assembly and service
Create a complete system solution with optimized functions
Allow you to flange one or more directional valves as well as pumps, cylinders, motors and filters.

IV Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3502/US

Parker Rotary Manifolds


Parker Hannifin Hydraulic Cartridge Systems introduces a new offering to its already extensive
product line - the Rotary Manifold.
Parker Rotary Manifolds are used in applications where multiple rotations of a mechanical
structure are required. A hydraulic rotary manifolds primary function is to allow oil, water,
gases and electronics to pass through it while allowing a 360 degree constant rotation.
Depending on the application, these manifolds are manufactured in various configurations and
sizes containing up to 20 stations and can operate at pressures as high as 7,500 psi.

Innovative GLIDELOC Seals


Exceptional Performance With the Parker Rotary
Parkers Rotary Manifolds are designed to Manifold, the GLIDELOC
provide leak-free performance in the most Seal uses locking tabs
rigorous applications. Parkers unique to secure the o-ring
step shaft design, proprietary seal design into the barrel.
and non-welded barrel ensure the user This locking
of extensive service life while providing a design assures
compact and easy to fit solution. that the o-ring will
not go dynamic
when energized. This
means a significantly
longer life for the manifolds
sealing system.

Global
Applications
Common Superior Support
applications Parker collaborates closely with the customer to design
can include the rotary manifold to meet the specific requirements
aerial work platform of each application. In addition, Parkers Application
booms to hydraulic Engineering team will also supply design support for
excavators. These application mounting and bracketry to ensure the proper
manifolds replace complex installation of your custom designed manifold. This elevated
swivels and complicated hose level of customization guarantees the quality performance
routings, thereby saving weight you expect from a Parker product.
and space.

Parker Rotary Manifolds offer:


Direct barrel porting reduces leak point failure by omitting weld joints and provides greater port orientation flexibility
Compact Design- allows for easier installation and alleviates hose routing issues
Improved Sealing technology- increases life expectancy of rotary
Easily capable of continuous rotation while under pressure
Extensive lifecycle testing performed in-house

V Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3502/US Threaded Cartridge Valves and
Alphabetical Index Integrated Hydraulic Products
CV
SERIES DESCRIPTION PAGE NO. SERIES DESCRIPTION PAGE NO.
10SLC1-A ......... Normally Closed, Pilot to Close ....................................................... LE7 D3B125 ............ Single P.O. Check, Pilot on Port 3 ................................................ CV29
Valves
Check

10SLC2-A ......... Normally Closed, Pilot to Close ..................................................... LE11 D4A020 ............ Single P.O. Check, Pilot on Port 3 ................................................ CV27
10SLC2-B ......... Normally Closed, Vent to Open ..................................................... LE17 D4A040 ............ Single P.O. Check, Pilot on Port 3 ................................................ CV28
10SLC3-A ......... Normally Open, Vent to Close ....................................................... LE23 DF122C ............. Flow Control, N.C. ............................................................... PV25-PV26
SH 10SLC3-B ......... Normally Open, Vent to Close ....................................................... LE27 DF122N ............ Flow Control, N.O. ............................................................... PV49-PV50
16SLC1-A ......... Normally Closed, Pilot to Close ....................................................... LE8 DF161C ............. Flow Control, N.C. ............................................................... PV27-PV28
16SLC1-C ......... Normally Closed, Vent to Open ..................................................... LE10 DF201C ............. Flow Control, N.C. ............................................................... PV29-PV30
Shuttle
Valves

16SLC2-A ......... Normally Closed, Pilot to Close ..................................................... LE12 DFA125C21 ...... Flow Control, N.C. ............................................................... PV39-PV40
16SLC2-B ......... Normally Closed, Vent to Open ..................................................... LE18 DFA125C31 ...... Priority Flow Control, N.C. ................................................... PV53-PV54
16SLC3-A ......... Normally Open, Vent to Close ....................................................... LE24 DH103 .............. 3 Way, External Pilot, Normally Open, Vent to Atmosphere .... DC7-DC8
LM 16SLC3-B ......... Normally Open, Vent to Close ....................................................... LE28 DL081 .............. 2 Position, 2 Way, N.C. Poppet, Pull to Open ................................ MV1
Load/Motor

20SLC1-A ......... Normally Closed, Pilot to Close ....................................................... LE9 DL101 .............. 2 Position, 2 Way, N.C. Poppet, Pull to Open ................................ MV2
Controls

20SLC2-A ......... Normally Closed, Pilot to Close ..................................................... LE13 DM103 ............. 3 Way, Rotary Spool ............................................................. MV5-MV6
20SLC2-B ......... Normally Closed, Vent to Open ..................................................... LE19 DM104 ............. 4 Way, Rotary Spool ............................................................. MV7-MV8
A02A2 ............... Direct Acting Relief, Ball Type ............................................. PC15-PC16 DMH085C1 ....... 3 Position, 4 Way, Closed Center,
A02B2 ............... Direct Acting Relief, Poppet Type ........................................ PC17-PC18 ......................... Pull to Shift and Push to Shift ........................................... MV11-MV12
FC A04B2 ............... Direct Acting Relief, Poppet Type ........................................ PC21-PC22 DMH085C2 ....... 3 Position, 4 Way, Open Center,
A04B2*CE ........ Direct Acting Relief, Poppet Type ........................................ PC23-PC24 ......................... Pull to Shift and Push to Shift ........................................... MV11-MV12
Controls

A04C2 ............... Direct Acting Relief, Spool Type .......................................... PC25-PC26 DMH085C4 ....... 3 Position, 4 Way, Float Center,
Flow

A04H3 .............. Pilot Operated Vented Relief ................................................ PC53-PC54 ......................... Pull to Shift and Push to Shift ........................................... MV11-MV12
A04J2 ............... Direct Acting Cross-over Relief ........................................... PC59-PC60 DMH085C9 ....... 3 Position, 4 Way, Tandem Center,
A04J2*CE ......... Direct Acting Cross-over Relief ........................................... PC61-PC62 ......................... Pull to Shift and Push to Shift ........................................... MV11-MV12
PC
A04K2 ............... Pilot Operated Spool Type Kick Down ................................. PC47-PC48 DS161 .............. 2 Position, 2 Way, N.C. or N.O. ........................................... SV23-SV24
A06G2 .............. Pilot Operated Spool Type ................................................... PC43-PC44 DS162 .............. 2 Position, 2 Way ................................................................ SV57-SV58
Pressure
Controls

A06H3 .............. Pilot Operated Vented Relief ................................................ PC55-PC56 DS163 .............. 2 Position, 3 Way ................................................................ SV71-SV72
A06P2 ............... Pilot Operated Poppet Type ................................................. PC73-PC74 DS201 .............. 2 Position, 2 Way, N.C. or N.O. ........................................... SV27-SV28
AP01B2YP ........ Increase Pressure/Increase Current ........................................ PV7-PV8 DSH081 ............ 2 Position, 2 Way, N.C. or N.O. ........................................... SV15-SV16
LE AP01B2YR ........ Decrease Pressure/Increase Current ................................... PV13-PV14 DSH082 ............ 2 Position, 2 Way ................................................................ SV51-SV52
AP02B2YP ........ Increase Pressure/Increase Current ...................................... PV9-PV10 DSH083 ............ 2 Position, 3 Way ................................................................ SV62-SV64
DSH084 ............ 2 Position, 4 Way ................................................................ SV75-SV76
Elements

AP02B2YR ........ Decrease Pressure/Increase Current ................................... PV15-PV16


AP04G2YP ........ Increase Pressure/Increase Current .................................... PV11-PV12 DSH101 ............ 2 Position, 2 Way, N.C. or N.O. ........................................... SV19-SV20
Logic

AP04G2YR ....... Decrease Pressure/Increase Current ................................... PV17-PV18 DSH102 ............ 2 Position, 2 Way ................................................................ SV55-SV56
AS04G2 ............ Solenoid Operated Unloading Relief .................................... PC49-PC50 DSH103 ............ 2 Position, 3 Way ................................................................ SV68-SV70
DC ASH-04 ............. In-Line Shuttle,-4 Male JIC .................................................... SH8-SH9 DSH104 ............ 2 Position, 4 Way ................................................................ SV79-SV80
ASH-06 ............. In-Line Shuttle,-6T ................................................................. SH8-SH9 DSH121 ............ 2 Position, 2 Way, N.C. or N.O. ........................................... SV21-SV22
Directional

B02E3F ............. Direct Acting, 2P-3W, Int. Pilot, Int. Drain ........................... PC91-PC92 DSH125 52 ....... 3 Position, 4 Way ............................................................ SV101-SV102
Controls

B04C3 ............... Pilot Operated, Kick Down ................................................... PC89-PC90 DSH125 54 ....... 3 Position, 4 Way ............................................................ SV103-SV104
B04D3 .............. Pilot Operated, Reverse Check, Ext. Drain ........................... PC87-PC88 DSH125 57 ....... 3 Position, 4 Way ............................................................ SV105-SV106
B04E3 ............... Direct Acting, 2P-3W, Int. Pilot, Int. Drain ........................... PC93-PC94 DSH125 59 ....... 3 Position, 4 Way ............................................................ SV107-SV108
MV B04F3 ............... Direct Acting, 2P-2W, N.C., Ext. Pilot, Int. Drain ............... PC99-PC100 DSH161 ............ 2 Position, 2 Way, N.C. or N.O. ........................................... SV25-SV26
B04G3 .............. Direct Acting, 2P-2W, N.O., Ext. Pilot, Int. Drain ............. PC101-PC102 DSH164 ............ 2 Position, 4 Way ................................................................ SV81-SV82
B04H4 .............. Direct Acting, 2P-2W, N.C., Ext. Pilot, Ext. Drain ............. PC103-PC104 DSL081 ............ 2 Position, 2 Way, N.C. or N.O. ........................................... SV13-SV14
Manual

DSL082 ............ 2 Position, 2 Way ................................................................ SV49-SV50


Valves

B04J4 ............... Direct Acting, 2P-2W, N.O., Ext. Pilot, Ext. Drain ............. PC107-PC108
B04K4 ............... Direct Acting, 2P-3W, N.O., Ext. Pilot, Int. Drain ............. PC109-PC110 DSL083 ............ 2 Position, 3 Way ................................................................ SV59-SV61
C02A3 ............... Direct Acting Reducing/Relieving .................................... PC111-PC112 DSL084 ............ 2 Position, 4 Way ................................................................ SV73-SV74
SV CB101 ............... Load Control Cartridge Valve ................................................. LM5-LM6 DSL101 ............ 2 Position, 2 Way, N.C. or N.O. ........................................... SV17-SV18
CDP(H)081 ....... Dual P.O. Check Package ..................................................... CV33-CV34 DSL102 ............ 2 Position, 2 Way ................................................................ SV53-SV54
CDP(H)103 ....... DSL103 ............ 2 Position, 3 Way ................................................................ SV65-SV67
Solenoid

Dual P.O. Check Package ..................................................... CV35-CV36


Valves

CDP(H)161 ....... Dual P.O. Check Package, Steel Body .................................. CV37-CV38 DSL104 ............ 2 Position, 4 Way ................................................................ SV77-SV78
CP084P ............ Single P.O. Check, Pilot on Port 1 ................................................ CV18 DSL105 ............ 3 Position, 4 Way ................................................................ SV91-SV92
CPC101P .......... Pilot to Close Check, Pilot on Port 3 ............................................ CV30 DSL201 ............ 2 Position, 2 Way, N.C. or N.O. ........................................... SV29-SV30
PV CPD084P .......... Dual P.O. Check Cartridge ............................................................ CV32 DSP105C1 ........ 3 Position, 4 Way - Closed Center ....................................... PV59-PV61
CPH104P ..........
Proportional

Single P.O. Check, Pilot on Port 1 ................................................ CV19 DSP105C4 ........ 3 Position, 4 Way - Float Center .......................................... PV59-PV61
CPH124P .......... Single P.O. Check, Pilot on Port 1 ................................................ CV20 E2*020 ............. Load Control Cartridge Valve ............................................. LM17-LM18
Valves

CS041B ............ Cartridge Shuttle ............................................................................ SH5 E2*040 ............. Load Control Cartridge Valve ............................................. LM19-LM20
CSH101B .......... Cartridge Shuttle ............................................................................ SH7 E2*060 ............. Load Control Cartridge Valve ............................................. LM27-LM28
CSP(H)081 ....... Single P.O. Check Package .................................................. CV21-CV22 E2*1 ................. Load Control Cartridge Valve ............................................. LM21-LM22
CE CSP(H)103 ....... Single P.O. Check Package .................................................. CV23-CV24 E2*1R .............. Load Control Cartridge Valve ............................................. LM25-LM26
Electronics

CSP(H)161 ....... Single P.O. Check Package, Steel Body ............................... CV25-CV26 E2*1S ............... Load Control Cartridge Valve ............................................. LM23-LM24
CVH081P .......... Cartridge Check, Poppet Type ........................................................ CV9 E2*125 ............. Load Control Cartridge Valve ............................................. LM29-LM30
Coils &

CVH103P .......... Cartridge Check, Poppet Type ...................................................... CV10 E2*300 ......................................................................................................... LM31-LM32
CVH104P .......... Cartridge Check, Poppet Type 2 to 1 Flow Path ............................ CV16 E6*1 ................. Load Control Cartridge Valve ............................................. LM37-LM38
CVH121P .......... Cartridge Check, Poppet Type ...................................................... CV12 E6A060*409 ..... Load Control Cartridge Valve, 3:1 Ratio ............................ LM41-LM42
BC CVH161P .......... Cartridge Check, Poppet Type ...................................................... CV14 E6B020 ............. Load Control Cartridge Valve, 4.5:1 Ratio ......................... LM33-LM34
CVH201P .......... Cartridge Check, Poppet Type ...................................................... CV15 E6B040 ............. Load Control Cartridge Valve, 3:1 Ratio ............................ LM39-LM40
Bodies &
Cavities

D0WB2 ............. Cartridge Check, Ball Type .............................................................. CV7 E6B060*409 ..... Load Control Cartridge Valve, 3:1 Ratio ............................ LM41-LM42
D02B2 .............. Cartridge Check, Ball Type .............................................................. CV8 E6K020 ............. Load Control Cartridge Valve, 15:1 Ratio .......................... LM35-LM36
D04B2 .............. Cartridge Check, Ball Type ............................................................ CV11 E9*1 ................. Load Control Cartridge Valve ............................................. LM49-LM50
D04F2 ............... Check With Thermal Relief, Relieving Port 2 to 1 ......................... CV39 FA101 ............... Restrictive Flow Control, Reverse Check, Adjustable ............ FC25-FC26
TD D06B2P ............ Cartridge Check, Poppet Type ...................................................... CV13 FC101 ............... Restrictive Flow Control, Reverse Check, Tuneable .............. FC27-FC28
D06C2 .............. Cartridge Check, Poppet Type 2 to 1 Flow Path ............................ CV17 FCP101 ............. Priority Type, with Bypass ............................................................. FC39
Technical

D1A060 ............ Check Valve Insert, Ball Type .......................................................... CV5 FCPH121 .......... Priority Type, with Bypass .................................................... FC41-FC42
Denotes New Winners Circle Product Line.
Data

D1B125 ............ Check Valve Insert, Ball Type .......................................................... CV6

VI Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3502/US Threaded Cartridge Valves and
Alphabetical Index Integrated Hydraulic Products
CV
SERIES DESCRIPTION PAGE NO. SERIES DESCRIPTION PAGE NO.
FCR101 ............. Restrictive Type, Press. Compensators ......................................... FC37 MHC-022-S*** Load Control Cartridge Valve ............................................... LM9-LM10

Valves
Check
FCR161 ............. Restrictive Type, Press. Compensators ......................................... FC38 MHC-022-V*** Load Control Cartridge Valve ............................................... LM9-LM10
FDC101 ............. Flow Divider/Combiner ......................................................... FC43-FC44 MMB-015-**** Motor Load Control ........................................................... LM43-LM45
FP101 ............... Priority Type, with Bypass .................................................... FC31-FC32 MMB-025-**** Motor Load Control ........................................................... LM46-LM48
FR101 ............... Restrictive Flow Control, Tuneable ....................................... FC19-FC20 N04A4 .............. 3 Way, Internal Vent, External Pilot ................................................ DC9 SH
FV101 ............... Needle Valve with Reverse Check, 1 to 2 Free Flow .............. FC15-FC16 N04B4 .............. 3 Way, Internal Vent, External Pilot .............................................. DC10
FV102 ............... Needle Valve with Reverse Check, 1 to 2 Free Flow .............. FC15-FC16 N04G4 .............. 3 Way, Vent to Atmosphere, External Pilot ................................... DC11

Shuttle
Valves
GH02 01 ........... 2 Position, 2 Way, N.C., with Flow Adj. ............................... SV31-SV32 N04H4 .............. 3 Way, Vent to Atmosphere, External Pilot ................................... DC12
GM0212 ........... 2 Position, 2 Way, N.O. Poppet, Push to Close ............................. MV3 N5A125 ............ 3 Way, 2 Position, External Drain, Open Transition ...................... DC13
GM0233 ........... 2 Position, 3 Way, Spool Type, Pull to Shift .................................. MV4 N5A300 ............ 3 Way, 2 Position, External Drain, Open Transition ...................... DC14
GM0240CS ....... 2 Position, 4 Way, Push to Shift .................................................. MV10 N5B125 ............ 3 Way, 2 Position, External Drain, Closed Transition .................... DC15 LM

Load/Motor
GM0240XS ....... 2 Position, 4 Way, Push to Shift .................................................... MV9 N5B300 ............ 3 Way, 2 Position, External Drain, Closed Transition .................... DC16

Controls
GP01 30 ........... Pressure Reducing Valve .................................................... PV19-PV20 N5C125 ............ 3 Way, 2 Position, External Drain, Diverter Valve, N.O. ................. DC17
GP02 51 ........... 4 Way, 3 Pos - Closed Center .............................................. PV55-PV56 N5C300 ............ 3 Way, 2 Position, External Drain, Diverter Valve, N.O. ................. DC18
GP02 53 ........... 4 Way, 3 Pos - Float Center ................................................. PV57-PV58 N5D125 ............ 3 Way, 2 Position, External Drain, Diverter Valve, N.C. ................. DC19
GS02 22 ........... 2 Position, 2 Way, N.C. Spool ................................................. SV7-SV8 N5D300 ............ 3 Way, 2 Position, External Drain, Diverter Valve, N.C. ................. DC20
GS02 27 ........... 2 Position, 2 Way, N.O. Spool ............................................... SV9-SV10 NVH081 ............ Needle Valve, Cartridge Type .................................................... FC7-FC8
FC
GS02 42 ........... 2 Position, 4 Way ................................................................ SV11-SV12 NVH101 ............ Needle Valve, Cartridge Type .................................................. FC9-FC10

Controls
GS02 51 ........... 3 Position, 4 Way ................................................................ SV83-SV84 PR103 .............. Direct Acting Reducing/Relieving .................................... PC113-PC114
PRCH101 ..........

Flow
GS02 53 ........... 3 Position, 4 Way ................................................................ SV85-SV86 Pilot Operated Reducing/Relieving w/Reverse Check ...... PC131-PC132
GS02 57 ........... 3 Position, 4 Way ................................................................ SV87-SV88 PRH081 ............ Pilot Operated Reducing/Relieving .................................. PC123-PC124
GS02 59 ........... 3 Position, 4 Way ................................................................ SV89-SV90 PRH082 ............ Pilot Operated Reducing ................................................. PC115-PC116
PC
GS02 72/73 ...... Bi-Directional Poppet, N.C. .................................................. SV33-SV34 PRH101 ............ Pilot Operated Reducing/Relieving .................................. PC125-PC126
GS02 77/78 ...... Bi-Directional Poppet, N.O. ................................................. SV41-SV42 PRH102 ............ Pilot Operated Reducing ................................................. PC117-PC118

Pressure
Controls
GS02 80/81 ...... Bi-Directional Poppet, N.C. .................................................. SV35-SV36 PRH121 ............ Pilot Operated Reducing/Relieving .................................. PC127-PC128
GS02 85/86 ...... Bi-Directional Poppet, N.O. ................................................. SV43-SV44 PRH122 ............ Pilot Operated Reducing ................................................. PC119-PC120
GS04 52D ......... 3 Position, 4 Way ................................................................ SV93-SV94 PRH161 ............ Pilot Operated Reducing/Relieving .................................. PC129-PC130
GS04 54D ......... 3 Position, 4 Way ................................................................ SV95-SV96 PRH162 ............ Pilot Operated Reducing ................................................. PC121-PC122 LE
GS04 57D ......... 3 Position, 4 Way ................................................................ SV97-SV98 R04A4 .............. 2 Way, Normally Open, Pilot to Close, Ext. Vent ............................. DC4

Elements
GS04 59D ......... 3 Position, 4 Way .............................................................. SV99-SV100 R04B4 .............. 2 Way, Normally Closed, Pilot to Open, Ext. Vent ........................... DC5
GS04 80/81 ...... Bi-Directional Poppet, N.C. .................................................. SV37-SV38 R04C3 .............. 2 Way, Normally Open, Pilot to Close ..................................... DC1-DC2

Logic
GS04 85/86 ...... Bi-Directional Poppet, N.O. ................................................. SV45-SV46 R04D3 .............. 2 Way, Normally Closed, Pilot to Open ........................................... DC3
GS06 80/81 ...... Bi-Directional Poppet, N.C. .................................................. SV39-SV40 R04E3 .............. Normally Closed, Pilot to Close ..................................................... LE14
GS06 85/86 ...... Bi-Directional Poppet, N.O. ................................................. SV47-SV48 R04F3 ............... Normally Closed, Vent to Open ..................................................... LE20 DC
GTP02 34 ......... Pressure Reducing Valve .................................................... PV21-PV22 R04G3 .............. Normally Open, Vent to Close ....................................................... LE29

Directional
GTP04 34 ......... Pressure Reducing Valve .................................................... PV23-PV24 R04H3 .............. Normally Open, Vent to Close ....................................................... LE25

Controls
HP02C .............. Flow Control, N.C. ............................................................... PV31-PV32 R06E3 .............. Normally Closed, Pilot to Close ..................................................... LE15
HP02P .............. Flow Control, N.O. ............................................................... PV41-PV42 R06F3 ............... Normally Closed, Vent to Open ..................................................... LE21
HP04C .............. Flow Control, N.C. ............................................................... PV35-PV36 R06G3 .............. Normally Open, Vent to Close ....................................................... LE30
HP04P .............. Flow Control, N.O. ............................................................... PV45-PV46 R06H3 .............. Normally Open, Vent to Close ....................................................... LE26 MV
J02A2 ............... Needle Valve, Cartridge Type .................................................... FC5-FC6 R08E3 .............. Normally Closed, Pilot to Close ..................................................... LE16
J02B2 ............... Needle Valve with Reverse Check, 2 to 1 Free Flow .............. FC13-FC14 R08F3 ............... Normally Closed, Vent to Open ..................................................... LE22

Manual
RAH081 ............

Valves
J02D3 ............... Priority Type, with Bypass .................................................... FC29-FC30 Pilot Operated Spool Type ................................................... PC35-PC36
J02E2 ............... Restrictive Flow Control, Adjustable ..................................... FC17-FC18 RAH101 ............ Pilot Operated Spool Type ................................................... PC37-PC38
J04C2 ............... Restrictive Flow Control, Adjustable ..................................... FC23-FC24 RAH101V .......... Pilot Operated Vented Relief ................................................ PC51-PC52
J04D3 ............... Priority Type, with Bypass .................................................... FC33-FC34 RAH121 ............ Pilot Operated Spool Type ................................................... PC39-PC40 SV
J04E2 ............... Restrictive Flow Control, Adjustable ..................................... FC21-FC22 RAH161 ............ Pilot Operated Spool Type ................................................... PC41-PC42

Solenoid
J06A2 ............... Needle Valve, Cartridge Type ................................................ FC11-FC12 RAH201 ............ Pilot Operated Spool Type ................................................... PC45-PC46

Valves
J1A125 ............. Priority Type, with Bypass .................................................... FC35-FC36 RD102 .............. Direct Acting Relief, Poppet Type ........................................ PC19-PC20
JP02C ............... Flow Control, N.C. ............................................................... PV33-PV34 RD163 .............. Direct Acting Differential Area Relief ................................... PC33-PC34
JP02P ............... Flow Control, N.O. ............................................................... PV43-PV44 RDCH103 ......... Direct Acting Differential Relief Assembly ........................... PC31-PC32
JP04C 21 .......... Flow Control, N.C. ............................................................... PV37-PV38 RDH042 ............ Direct Acting Relief, Poppet Type ............................................ PC7-PC8 PV
RDH081 ............

Proportional
JP04C 31 .......... Priority Flow Control, N.C. ................................................... PV51-PV52 Direct Acting Relief, Ball Type ............................................... PC9-PC10
JP04P ............... Flow Control, N.O. ............................................................... PV47-PV48 RDH082 ............ Direct Acting Relief, Poppet Type ........................................ PC11-PC12

Valves
K02A3 ............... Cartridge Shuttle ............................................................................ SH6 RDH083 ............ Direct Acting Differential Area Relief ................................... PC27-PC28
K04B3 ............... Spool Type Shuttle ....................................................................... SH10 RDH101 ............ Direct Acting Relief, Ball Type ............................................. PC13-PC14
K04C3 ............... Spool Type, Spring Centered, All Ports Closed ............................. SH12 RDH103 ............ Direct Acting Differential Area Relief ................................... PC29-PC30
K04D3 .............. Spool Type Shuttle ....................................................................... SH11 RU101 .............. Direct Acting Unloading ...................................................... PC69-PC70 CE
SV103 ...............
Electronics
K04F3 ............... Spool Type, Spring Centered, All Ports Open ............................... SH14 Direct Acting, 2P-3W, Int. Pilot, Ext. Drain .......................... PC95-PC96
K04G3 .............. Spool Type Shuttle, Inverse ......................................................... SH15 SV104 ............... Direct Acting, 2P-2W, N.O., Ext. Pilot, Ext. Drain ............. PC105-PC106
Coils &

K2A005 ............. Poppet Insert Type ......................................................................... SH4 SV105 ............... Direct Acting, 2P-2W, N.C., Ext. Pilot, Int. Drain ................. PC97-PC98
K3A125 ............. Spool Type, Spring Centered, All Ports Closed ............................. SH13 SVCH101 .......... Pilot Operated with Reverse Check Assembly ..................... PC85-PC86
KSWA3 ............. Ball Insert Type .............................................................................. SH3 SVH081 ............ Pilot Operated, Int. Pilot, Ext. Drain ..................................... PC75-PC76
L04A3 ............... Flow Divider/Combiner ......................................................... FC45-FC46 SVH101 ............ Pilot Operated, Int. Pilot, Ext. Drain ..................................... PC77-PC78 BC
L06A3 ............... Flow Divider/Combiner ......................................................... FC47-FC48 SVH102 ............ Pilot Operated, Ext. Pilot, Int. Drain ..................................... PC81-PC82
Bodies &
Cavities

L1A300 ............. Flow Divider/Combiner ......................................................... FC49-FC50 SVH161 ............ Pilot Operated, Int. Pilot, Ext. Drain ..................................... PC79-PC80
M04A4J ............ Direct Acting Piloting Unloading ......................................... PC71-PC72 SVH162 ............ Pilot Operated, Ext. Pilot, Int. Drain ..................................... PC83-PC84
MHB-015-L*** . Load Control Valve Assembly ............................................ LM11-LM13 XR101 .............. Direct Acting Cross-over Relief ........................................... PC57-PC58
MHB-015-W*** Load Control Valve Assembly ............................................ LM11-LM13 XRDH101 ......... Direct Acting Cross-over Relief ........................................... PC63-PC64
MHB-030-L*** . Load Control Valve Assembly ............................................ LM14-LM16 XRDH102 ......... Direct Acting Cross-over Relief w/Anti-Cav Check ............... PC65-PC66
TD
MHB-030-W*** Load Control Valve Assembly ............................................ LM14-LM16 XRDH103 ......... Direct Acting Cross-over Relief, Motor Mount .................... PC67-PC68
Technical

MHC-010-S*** Load Control Cartridge Valve ................................................. LM7-LM8


Denotes New Winners Circle Product Line.
Data

MHC-010-V*** Load Control Cartridge Valve ................................................. LM7-LM8

VII Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3502/US Threaded Cartridge Valves and
Alphabetical Index Integrated Hydraulic Products
CV
SERIES DESCRIPTION PAGE NO. SERIES DESCRIPTION PAGE NO.
Cartridge Valve Coils Standard Cavity Plugs
Valves
Check

CC ..................... 1/2 Solenoid Tubes ................................................................ CE3-CE4 Cavity Plugs ............................................................................................................. BC35
CA ..................... 5/8 Solenoid Tubes ................................................................ CE5-CE6
Unicoil .............. 1/2 Solenoid Tubes ................................................................ CE7-CE8 Cartpak Bodies
SH BD03-ABN ........ A and B Port Interrupt, Body Only ................................................ BC41
Unicoil .............. 5/8 Solenoid Tubes .............................................................. CE9-CE10
BD03-ABT ......... A and B Ports to Tank, Body Only ................................................ BC43
DS .................... 1/2 Solenoid Tubes ............................................................ CE11-CE12
BD03-ABX ........ A and B Port Crossover, Body Only .............................................. BC42
Shuttle
Valves

DS .................... 5/8 Solenoid Tubes ............................................................ CE13-CE14 BD03-ADB ........ A Port Drain to B, Body Only ........................................................ BC46
DS .................... 1 Solenoid Tubes ......................................................................... CE15 BD03-BDA ........ B Port Drain to A, Body Only ........................................................ BC45
BD03-DDX ........ Ports A and B Drain to Crossover Port, Body Only ....................... BC44
LM Electronics BD03-PN .......... P Port Interrupt, 2-Way, Body Only .............................................. BC36
Load/Motor

XPRO704 .......... Soft Start Valve Controller, 12/24 VDC .......................................... CE23 BD03-PN2 ........ P Port Interrupt, 2-Way, Body Only .............................................. BC37
Controls

XPRO704b ........ Soft Start and Stop Valve Controller, 12/24 VDC ........................... CE24 BD03-PNR ........ P Port Interrupt, Reducing Function, Body Only .......................... BC38
XPRO804 .......... Power Saver Controller, 12/24 VDC PWM ..................................... CE25 BD03-PNS ........ P Port Interrupt, Sequencing Function, Body Only ....................... BC39
BD03-PT ........... P to T, Body Only ......................................................................... BC40
XPRO902 .......... 12 VDC PWM Controller, 110Hz, 19W ................................. CE17-CE18
FC XPRO902d ........ 12 VDC PWM Controller, 95-230Hz, 19W ........................... CE19-CE20
Special Bodies and Cavities
XPRO902rid ..... 12 VDC PWM Controller, 95-230Hz, 19W, Multi-adj. ........... CE21-CE22 CAV0W-2 .......... 2 Port ........................................................................................... BC47
Controls

XPRO904 .......... 24 VDC PWM Controller, 110Hz, 19W ................................. CE17-CE18 CAVSW-3 .......... 3 Port ........................................................................................... BC48
Flow

XPRO904d ........ 24 VDC PWM Controller, 95-230Hz, 19W ........................... CE19-CE20 CAVT11A .......... 3 Port or 4 Port Dual .................................................................... BC49
XPRO904rid ..... 24 VDC PWM Controller, 95-230Hz, 19W, Multi-adj. ........... CE21-CE22 CAVT21A .......... 4 Port ........................................................................................... BC50
XPRO932 .......... 12 VDC PWM Controller, 110Hz, 30W ................................. CE17-CE18 2C ..................... 2 Port ........................................................................................... BC51
PC 2G .................... 2 Port ........................................................................................... BC52
XPRO932d ........ 12 VDC PWM Controller, 95-230Hz, 30W ........................... CE19-CE20
2R .................... 2 Port ........................................................................................... BC53
Pressure

XPRO932rid ..... 12 VDC PWM Controller, 95-230Hz, 30W, Multi-adj. ........... CE21-CE22
Controls

2U .................... 2 Port ........................................................................................... BC54


XPRO934 .......... 24 VDC PWM Controller, 110Hz, 30W ................................. CE17-CE18
2X ..................... 2 Port ........................................................................................... BC55
XPRO934d ........ 24 VDC PWM Controller, 95-230Hz, 30W ........................... CE19-CE20
3A ..................... 3 Port ........................................................................................... BC56
XPRO934rid ..... 24 VDC PWM Controller, 95-230Hz, 30W, Multi-adj. ........... CE21-CE22 3C ..................... 3 Port or 4 Port Dual .................................................................... BC57
LE
3J ..................... 3 Port ........................................................................................... BC58
Standard Bodies and Cavities 3K ..................... 3 Port ........................................................................................... BC59
Elements

C04-2 ............... 04 Size, 2 Way ............................................................................... BC7 3M .................... 3 Port or 4 Port Dual .................................................................... BC60
Logic

C04-3 ............... 04 Size, 3 Way ............................................................................... BC8 3X ..................... 3 Port ........................................................................................... BC61
C08-2 ............... 08 Size, 2 Way ............................................................................... BC9 3Z ..................... 3 Port ........................................................................................... BC62
C08-3 ............... 08 Size, 3 Way ............................................................................. BC10 4C ..................... 4 Port ........................................................................................... BC63
DC
C08-4 ............... 08 Size, 4 Way ............................................................................. BC11 5A ..................... 5 Port ........................................................................................... BC64
Directional

C09-2 ............... 09 Size, 2 Way ............................................................................. BC12 53-1 .................. 3 Port or 4 Port Dual .................................................................... BC65
Controls

C10-2 ............... 10 Size, 2 Way ............................................................................. BC13 54-1 .................. 3 Port ........................................................................................... BC66
C10-2T ............. 10 Size, 2 Way, T Body ............................................................. BC14 68-1 .................. 3 Port or 4 Port Dual .................................................................... BC67
C10-3 ............... 10 Size, 3 Way ............................................................................. BC15 91-1 .................. 3 Port ........................................................................................... BC68
MV C10-3S ............. 10 Size, 3 Way, Short ................................................................... BC16 100-1 ................ 5 Port ........................................................................................... BC69
C10-4 ............... 10 Size, 4 Way ............................................................................. BC17
C11-3 ............... 11 Size, 3 Way ............................................................................. BC18 Technical Data
Manual
Valves

C12-2 ............... 12 Size, 2 Way ............................................................................. BC19 Basic Hydraulic Formulas .......................................................................................... TD1
C12-3 ............... 12 Size, 3 Way ............................................................................. BC20 Ratings and Testing ................................................................................................... TD1
C12-3L ............. 12 Size, 3 Way, Long .................................................................... BC21
Temperature Ratings ................................................................................................. TD1
SV C12-4 ............... 12 Size, 4 Way ............................................................................. BC22
Viscosity .................................................................................................................... TD1
C12-4L ............. 12 Size, 4 Way, Long .................................................................... BC23
Pressure Ratings ....................................................................................................... TD1
Solenoid

C16-2 ............... 16 Size, 2 Way ............................................................................. BC24


Valves

C16-3 ............... 16 Size, 3 Way ............................................................................. BC25 Thermal Shock .......................................................................................................... TD1
C16-3S ............. 16 Size, 3 Way, Short ................................................................... BC26 Service and Components ........................................................................................... TD1
C16-4 ............... 16 Size, 4 Way ............................................................................. BC27 Limitations in Use ...................................................................................................... TD1
PV C20-2 ............... 20 Size, 2 Way ............................................................................. BC28 Seal Material Selection .............................................................................................. TD2
Proportional

C20-3S ............. 20 Size, 3 Way, Short ................................................................... BC29 Hydraulic Fluids ......................................................................................................... TD3
Hydraulic Filtration .................................................................................................... TD3
Valves

Counterbalance Cavities and Bodies


Application of Product ............................................................................................... TD3
MHC-010 .......... Single and Dual Counterbalance Bodies ....................................... BC30
Offer of Sale .............................................................................................................. TD4
MHC-022 .......... Single and Dual Counterbalance Bodies ....................................... BC31
CE MHC-025 .......... Single and Dual Counterbalance Bodies ....................................... BC32
MHC-050 .......... Single and Dual Counterbalance Bodies ....................................... BC33
Electronics
Coils &

Pilot Piston Cavities


10 Size .............. 10 Size Cavity for Single Check and Pilot Piston .......................... BC34
10 Size .............. 10 Size Cavity for Dual Check and Pilot Piston ............................. BC34
BC 16 Size .............. 16 Size Cavity for Single Check and Pilot Piston .......................... BC34
16 Size .............. 16 Size Cavity for Dual Check and Pilot Piston ............................. BC34
Bodies &
Cavities

TD
Technical
Data

VIII Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3502/US Threaded Cartridge Valves and
Integrated Hydraulic Products
CV

Check Valves CV1-CV39

Valves
Check
SH

Shuttle Valves SH1-SH15

Shuttle
Valves
LM

Load/Motor
Load and Motor Control Valves LM1-LM50

Controls
FC

Flow Control Valves FC1-FC50

Controls
Flow
PC

Pressure Control Valves PC1-PC132

Pressure
Controls
LE

Logic Element Valves LE1-LE30

Elements
Logic
DC

Directional
Directional Control Valves DC1-DC20

Controls
MV

Manual Valves MV1-MV12

Manual
Valves
SV

Solenoid Valves SV1-SV108

Solenoid
Valves
PV

Proportional
Proportional Valves PV1-PV61
Valves
CE
Electronics

Coils and Electronics CE1-CE25


Coils &

BC

Bodies and Cavities BC1-BC69


Bodies &
Cavities

TD
Technical

Technical Data TD1-TD4


Data

IX Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3502/US

The HCSD Story . . .


The Hydraulic Cartridge Systems Division (HCSD), headquartered in Lincolnshire, Illinois,
was born as a Parker manufacturing division on July 1st, 2000. Through several acquisitions,
Parker has assembled a line-up of respected cartridge valve manufacturers, including;
Sterling Hydraulics, Waterman Hydraulics, Fluid Power Systems (FPS), Gresen, and CEC.
Through this assembly of products, Parkers product offering is now one of the most extensive
in the industry.

The objective and mission of HCSD:


The Hydraulic Cartridge Systems Division of Parker Hannifin is a world leader in the
manufacture of hydraulic cartridge products and integrated systems. We will provide the best
quality and value to our Customers by delivering Premier Customer Service, rapid application
support, advanced technology products, and value-based engineering solutions.

The division currently has four locations, each providing various aspects of cartridge valve
manufacturing, assembly, test, as well as manifold machining and other secondary operations.
Each location is supported by a local management team, along with an experienced and well-
trained work force. Parker believes the best in efficient manufacturing and Premier Customer
Service cannot be achieved unless the process of continuous improvement is in place. We are
continuously measuring our progress to exceed the expectation of the market through Kaizen
events, Lean initiatives, 5 S quality programs, and other continuous improvement programs.

Lincolnshire
operations . . .

The division head-


quarters is located
in Lincolnshire,
Illinois, which is
approximately 15
miles north of
Chicago, and a 20 minute drive north of OHare airport. This location houses many of the
primary division functions such as Marketing, Product Management, Engineering, Customer
Service, Accounting, Quality Engineering, and Research & Development. In addition to the
office headquarters, the 85,000 sq. ft. building features a newly remodeled plant space for the
assembly and test of cartridge valves and manifold products. With its experienced, dedicated
work force, Parker is proud to present Lincolnshire as the assembly and test home for the new
Winners Circle product line. This location serves as the primary contact point for customers,
distributors, and Parker sales representatives.

X Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3502/US

Monterrey operations . . .
The Monterrey cartridge valve assembly
and test operations are housed in a well-
equipped modern manufacturing facility,
just 2 hours west of McAllen, Texas. Parker
began operations in this new facility in
1998. This location focuses primarily on
the assembly and test of cartridge valves.
IHD actually shares this facility with other Parker divisions in order to maximize the efficiency
of the assembly and support processes.

All Parker facilities are ISO 9000 registered, ensuring complete customer satisfaction.

XI Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3502/US

The HCSDE Story . . .


With its developments in integrated hydraulic products, Parker has decided to penetrate
the expanding European market by creating a focused resource with engineering and
manufacturing capability for both cartridge valves and manifold systems. This division is
named Hydraulic Cartridge Systems Division-Europe based in Crewkerne - England.
This allows Parker to take advantage of its strengths in product offerings and truly provide
OEMs with one stop shopping. With the vast resources of its many divisions available,
Parker has the unique ability to adapt other Parker products within speciality manifolds,
beyond just the integration of valve products.
Our objectives and development are linked directly with HCSD and are in line with our
Global Hydraulics Group goals. HCSDE have three locations, with its headquarters in
Crewkerne, a manifold production facility in Boras - Sweden, and the volume cartridge
production facility in Chomutov. - Czech Republic. The following is a brief review of each
location:

Crewkerne operations . . .

The Crewkerne operation is the


headquarters for Hydraulic Cartridge
Systems Division-Europe. This facility
houses a complete machine shop well
equipped to accommodate a large variety
of turning, grinding, and milling operations
to support complete cartridge valve
manufacturing. Also, the Crewkerne facility
has a complete Assembly and Test
operation with automated assembly and
testing in selected cells. Recent
investments have improved efficiency
which has allowed capacity to grow to over 1,500,000 valves per year. The following activities
are supported from this location:

 Customer Service
 Product and Technical Support
 Manifold Systems
 Quality Assurance Systems
 Manufacturing Support
 Finance
 Purchasing
 Marketing
 Engineering Support for Cartridge Valves

XII Parker Hannifin Corporation


Hydraulic Cartridge Systems
Catalog HY15-3502/US

Boras operations . . .
The manifold systems team is
located in Boras Sweden, 30 miles East
of Gothenburg. This team focuses on
the production on integrated hydraulic
circuits which are incorporated into mobile
systems. By working closely with the
Mobile Controls Division (M.C.D.) we are
also able to take full advantage of Parkers
unique spool valve product offering, and
systems engineering expertise. Boras also
has a prototype Speed Shop capability, and
provides local manifold design and production support for the Nordic region. Manifold system
application engineering and manufacturing capability is also available at several other Parker
Sales locations throughout Europe. Parker can provide both standard circuit and custom-
engineered hydraulic solutions. Each facility uses compatible CAD / CAM packages to enable
the resource to be shared whilst keeping the application engineering close to our customers.

Chomutov operations . . .
The Chomutov cartridge valve and
simple Manifold system assembly and
test operation is located in a brand new
manufacturing facility, 50 miles north of
Prague in the city of Chomutov - Czech
Republic. The facility is based on LEAN
manufacturing techniques Such as Value
Stream Mapping, Point-of-Use
Inventory, Kanban controls, 5S, Visual
factory, Small batch flow, Balanced work flow etc. and is operated using fully equipped cells
which are dedicated to specific product families with each one having a state-of-the-art test
stand with manual or automated electronic controls and quick change-over fixtures.
Products are distributed to customers throughout Europe via the Cartridge Valve
Distribution Center (C.V.D.C) in conjunction with the United Parcel Service (U.P.S.)

All Parker facilities are ISO 9000 registered, ensuring complete customer satisfaction.

XIII Parker Hannifin Corporation


Hydraulic Cartridge Systems
Extensive Hydraulic Product Offering

Accumulators Compact Hydraulics Cylinders


Piston, bladder and diaphragm type Self-contained with a motor, gear Standard and custom hydraulic
accumulators, gas bottles and Kleen- pump, reservoir, internal valving, load cylinders for industrial and mobile
Vent reservoir isolators. hold checks and relief valves. applications.
www.parker.com/accumulator www.parker.com/oildyne www.parker.com/hydcyl

Filtration Integrated Hydraulic Circuits Motors


Pressure and return line filters Solutions for complex circuits that Full line of high and low speed motors
enhances machine life, reduces include threaded cartridge valves provides power up to 15,000 in-lbs
maintenance and lowers costs. integrated into a single manifold. of torque.
www.parker.com/hydraulicfilter www.parker.com/hcs www.parker.com/pumpmotor

Power Units Pumps Rotary Actuator


The most complete line of standard, Broad line of energy- efficient Industry leader in the design and man-
pre-engineered, cataloged hydraulic hydraulic pumps that includes piston, ufacture of hydraulic rack and pinion,
power units in the industry. vane and gear pumps. and vane style rotary actuators.
www.parker.com/hydraulicpump www.parker.com/hydraulicpump www.parker.com/actuator

Electronics/Remote Controls Power Take Off Valves and Controls


Parkers unique IQAN approach Parker Chelsea leads the industry for Hydraulic valves for virtually every
combines sturdy, well-tested hardware engineering, innovation and perfor- hydraulic equipment application, from
with intelligent, flexible computing power. mance in auxiliary power systems. simple to precise control.
www.parker.com/iqan www.parker.com/chelsea www.parker.com/hydraulicvalve
Parker Hydraulic Cartridge Systems
The Hydraulic Cartridge Systems Division is a leader in the cartridge valve and custom
manifold industry, serving both the mobile and industrial machine markets.

Our team of application engineers and manufacturers consistently challenge valve standards
to achieve the most efficient and flexible designs. They work hard to provide the highest
level of customer satisfaction and support. Discover how Parker HCS can be the ONE
source for all your hydraulic cartridge and manifold needs.

Have questions? Contact us at [email protected].

Parker Hannifin Corporation Parker Hannifin Ltd. Parker Hannifin Corporation


Hydraulic Cartridge Systems Hydraulic Cartridge Systems Europe Corporate Headquarters
595 Schelter Road Blacknell Lane 6035 Parkland Blvd
Lincolnshire, IL 60069 Crewkerne, Somerset Cleveland, OH 44124
USA TA18 8LL, UK USA
phone 847 955 5000 phone +44 (0) 1460 271800 Tel: 216-896-3000
fax 847 383 8905 fax +44 (0) 1460 271801 Fax: 216-896-4000
www.parker.com/hcs

For information, please contact Parker toll free at 1-800-C-PARKER (1-800-272-7537). Outside of North
America contact us via Freephone at 00800 27 27 5374.

2010 Parker Hannifin Corporation Print HY15-3502/USA,EU 9/2010

Parker Hannifin Corporation Parker Hannifin Ltd.


Hydraulic Cartridge Systems Hydraulic Cartridge Systems Europe
595 Schelter Road Blacknell Lane
Lincolnshire, IL 60069 Crewkerne, Somerset
phone 847 955 5000 TA18 8LL, UK
fax 847 383 8905 phone +44 (0) 1460 271800
www.parker.com/hcs fax +44 (0) 1460 271801