User Manual
Revision 2.053
English
Dear customer, we thank you for your attention and we remind you that you
need to check that the following document is:
Page
Updated
INDEX 2 Related to the product you own
UPDATED DOCUMENTATION 2
REVISION LIST 2 To obtain the most recently updated document, note the document code that
WARNING 2 appears at the top right-hand corner of each page of this document.
TRADEMARKS 2
SECURITY ALERT 3 With this Document Code go to web page www.adfweb.com/download/ and
CONNECTION SCHEME 4 search for the corresponding code on the page. Click on the proper Document
CHARACTERISTICS 8 Code and download the updates.
POWER SUPPLY 9
SET COMMUNICATION PARAMETERS 10 To obtain the updated documentation for the product that you own, note the
CONFIGURATION 10 Document Code (Abbreviated written "Doc. Code" on the label on the product)
FUNCTION MODES 10 and download the updated from our web site www.adfweb.com/download/
USE OF COMPOSITOR SW67029 11
NEW PROJECT / OPEN PROJECT 11
SET COMMUNICATION 12 REVISION LIST:
M-BUS 13
UPDATE DEVICE 25 Revision Date Author Chapter Description
CHARACTERISTICS OF THE CABLE 27 2.020 19/07/2010 Fl All Software changed (v1.900)(v1.200)
MECHANICAL DIMENSIONS 28 2.030 22/09/2010 Fl All Software changed (v2.200)(v2.200)
ORDERING INFORMATIONS 30 2.040 05/11/2010 Fl All Software changed (v2.203)
ACCESSORIES 31 2.050 02/12/2010 Fl All Software changed (v2.300)
DISCLAIMER 32 2.051 19/01/2011 Fl All Revision
OTHER REGULATIONS AND STANDARDS 32 2.052 01/02/2012 Fl All Revision
WARRANTIES AND TECHNICAL SUPPORT 33 2.053 04/03/2013 Nt All Added new chapters
RETURN POLICY 33
PRODUCTS AND RELATED DOCUMENTS 33
WARNING:
ADFweb.com reserves the right to change information in this manual about our
product without warning.
ADFweb.com is not responsible for any error this manual may contain.
TRADEMARKS:
SECURITY ALERT:
GENERAL INFORMATION
To ensure safe operation, the device must be operated according to the instructions in the manual. When using the device are required for
each individual application, legal and safety regulation. The same applies also when using accessories.
INTENDED USE
Machines and systems must be designed so the faulty conditions do not lead to a dangerous situation for the operator (i.e. independent limit
switches, mechanical interlocks, etc.).
QUALIFIED PERSONNEL
The device can be used only by qualified personnel, strictly in accordance with the specifications.
Qualified personnel are persons who are familiar with the installation, assembly, commissioning and operation of this equipment and who
have appropriate qualifications for their job.
RESIDUAL RISKS
The device is state of the art and is safe. The instrument can represent a potential hazard if they are inappropriately installed and operated
by personnel untrained. These instructions refer to residual risks with the following symbol:
This symbol indicates that non-observance of the safety instructions is danger for people to serious injury or death and / or the
possibility of damage.
CE CONFORMITY
The declaration is made by us. You can send an email to [email protected] or give us a call if you need it.
CONNECTION SCHEME:
CHARACTERISTICS:
At the Converter can be connected up to 250 standard M-Bus devices. This number depends of the code expressed by the xxx number:
HD67029M-232 or HD67029M-485 support up to 20 M-Bus devices;
HD67029M-232-40 or HD67029M-485-40 support up to 40 M-Bus devices;
HD67029M-232-80 or HD67029M-485-80 support up to 80 M-Bus devices;
HD67029M-232-160 or HD67029M-485-160 support up to 160 M-Bus devices;
HD67029M-232-250 or HD67029M-485-250 support up to 250 M-Bus devices.
In the case of HD67029M-232-160 and or HD67029M-485-160 the device must be mounted on 35mm DIN rail which is horizontally
mounted on a wall or cabinet back-plate. To avoid obstructions to the airflow around the unit it is recommended to not cover the paths of
air.
In the case of HD67029M-232-250 and or HD67029M-485-250 the device must be mounted on 35mm DIN rail which is horizontally
mounted on a wall or cabinet back-plate. These units have a fan in the top of the enclosure. To avoid obstructions to the airflow around the
unit it is recommended to not cover the paths of air. Take care to not cover the fan. It is recommended to put the device into a ventilated
cabinet.
POWER SUPPLY:
The devices can be powered at 1521V AC and 1835V DC. The consumption depends to the code of the device. For more details see the
two tables below.
VAC VDC
Vmin Vmax Vmin Vmax
15V 21V 18V 35V
HD67029M-232-xxx HD67029M-485-xxx
Configurable Parameters:
Baud Rate of RS232/RS485 from 1200 to 115200 bps and of M-Bus from 300 to 38400 bps;
Parity of RS232/RS485 and M-Bus with None/Odd/Even.
Fixed Parameters:
1 Bit Start;
8 Bit Data;
1 Bit Stop.
The Baud Rate and the Parity of RS232/RS485 and M-Bus are configurable with the software.
CONFIGURATION:
You need Compositor SW67029 software on your PC in order to perform the following:
FUNCTION MODES:
For the device HD67029M-232 and HD6702M-485 it is possible to update the microprocessor program. Therefore there are two functions to
select from the boot jumper:
NORMAL MODE (factory setting, without BOOT jumper): with this setting the HD67029M-232 or HD67029M-485 is able to function as
an adapter M-Bus to Modbus on RS232/RS485;
BOOT MODE (with BOOT jumper): the boot mode is activated when the HD67029M-232 or HD67029M-485 is turned on. Eventual
program updates are available on the site www.adfweb.com
When the RUN Led blinks at frequency of about 1 second, the device functions in Normal Mode, otherwise if the run LED blinks more quickly
the device is in Boot Mode.
When launching the SW67029 the right window appears (Fig. 5).
The New Project button creates the folder which contains the entire device configuration.
A device configuration can also be imported or exported:
To clone the configurations of a Programmable M-Bus / Modbus - Converter in order to configure another device in the same manner,
it is necessary to maintain the folder and all its contents;
To clone a project in order to obtain a different version of the project, it is sufficient to duplicate the project folder with another name
and open the new folder with the button Open Project;
When a new project is created or an existent project is open, it will be possible to access the various sections of the software:
Set Communication;
M-Bus;
Update Device.
SET COMMUNICATION:
This section define the fundamental communication parameters of two buses, Modbus and M-Bus.
By Pressing the Set Communication button from the main window for SW67029 (Fig. 5) the
window Set Communication appears (Fig. 6).
The window is divided in two sections, one for the Modbus line (Serial) and the other for the M-Bus.
M-BUS
By Pressing the M-Bus button from the main window for SW67029 (Fig. 5) the window M-Bus Network appears (Fig. 7).
SECTION NODES:
In the section Nodes it is possible to create the nodes of M-Bus
line. In order to create a new node it is necessary to select which
address use, selecting Primary ID or Secondary ID, to makes
the requests and then insert the Primary Address (from 1 to 250)
or the Secondary Address (from 0 to 99999999) of M-Bus device in
the field ID Node M-Bus. In the field Description it is possible
to write a short description of the node.
In the field Node State it is possible to insert an address Modbus
that contain the Status of the M-Bus device. If you dont need to
know this, put this register at 0.
In the field Identification Number it is possible to insert an
address Modbus that contain the Identification Number of the M-Bus
device. You have to read two consecutive registers for knowing the
value. If you dont need to know this, put this register at 0.
If the field Convert BCD in Integer Identification Num. is
checked the Converter converts the Identification Number that is
normally expressed in BCD in a Integer.
In the field Swap Identification Num. it is possible to select the
swap mode of the Identification Number. If swap isnt necessary you
have to select None; otherwise see the section Swap
Identification (page 21) of this document for select the swap mode.
If the field Send SND_NKE is checked, the Converter send the
SND_NKE frame to start the communication.
In the field Send Reset App. Is checked the Converter send the
Application Reset command to the slave. In the field Variables
List it is possible to select which type of variables definition to use.
Figure 7: M-Bus Network window
If is selected By Type it is necessary to fill all fields, in the section
Variables, with the correct values; otherwise if By Position is selected you can insert the progressive number of the variable that you need
(page 15-16 for more information).
After that, pressing the ADD NODE button, a new node appears in the left side of the window. In order to modify a created node it is
necessary to select the desired node, change the wrong items and then press the MODIFY NODE button.
If the field Use Five Modbus Register and the Type of Data is Time Point it is possible to read the information of Year, Month,
Day, Hour, Minutes on five consecutive Modbus registers without decoding the data (if not selected the values are the same of the
reply of the slave device, so coded with a determinate structure). You have to insert the first Modbus Register.
If the field From BCD to Integer is checked the Converter converts the BCD value of variable in Integer format. This happens only
if the variable is in BCD format; if it isnt nothing changes.
If the field Convert in Float is checked the Converter converts the data into Float type. Every variable occupies two consecutive
Modbus Registers and the first one is the one defined in Modbus Register. In this case the float value is multiplied by the Modbus
Re Scale automatically.
Having completed this fields, to add the variable the button ADD VARIABLE must be pressed.
In order to modify a created variable it is necessary to select the desired variable, change the wrong items and then press the MODIFY
VARIABLE button.
Example:
0x04 - DIF
0x06 - VIF Energy
0x00 - Data (Byte 4of4)
0x00 - Data (Byte 3of4)
Second Variable ( 2 ) To be use in the Position field
0x00 - Data (Byte 2of4)
0x00 - Data (Byte 1of4)
0x44 - DIF
0x06 - VIF Energy
0x00 - Data (Byte 4Of4)
0x00 - Data (Byte 3Of4)
Third Variable ( 3 )
0x00 - Data (Byte 2Of4)
0x00 - Data (Byte 1Of4)
Other Variables
VIFE:
|_ Not Selected |_ Period of tariff months(s)
|_ Credit of the nominal local legal currency units |_ Period of tariff year(s)
|_ Debit of the nominal local legal currency units |_ dimensionless/ no VIF
|_ Access Number (transmission count) |_ Volts
|_ Medium (as in fixed header) |_ Ampere
|_ Manufacturer (as in fixed header) |_ Reset counter
|_ Parameter set identification |_ Comulation counter
|_ Model/Version |_ Control signal
|_ Hardware Version # |_ Day of week
|_ Firmware Version # |_ Week number
|_ Software Version # |_ Time point of day change
|_ Customer Location |_ State of parameter activation
|_ Customer |_ Special supplier information
|_ Access Code User |_ Duration since last comulation [hour(s)..year(s)]
|_ Access Code Operator |_ Operation time battery [hour(s)..year(s)]
|_ Access Code System Operator |_ Date and time of battery change
|_ Access Code Developer |_ Energy MWh
|_ Password |_ Energy GJ
|_ Error flags (binary) |_ Volume
|_ Error mask |_ Mass
|_ Digital Output (binary) |_ Volume 0,1 feet^3
|_ Digital Input (binary) |_ Volume 0,1 american gallon
|_ Baudrate [Baud] |_ Volume 1 american gallon
|_ response delay time [bittimes] |_ Volume flow 0,001 american gallon/min
|_ Retry |_ Volume flow 1 american gallon/min
|_ First storage # for cyclic storage |_ Volume flow 1 american gallon/h
|_ Last storage # for cyclic storage |_ Power MW
|_ Size of storage block |_ Power GJ/h
|_ Storage interval [sec(s)..day(s)] |_ Flow Temperature
|_ Storage interval month(s) |_ Return Temperature
|_ Storage interval year(s) |_ Temperature Difference
|_ Duration since last readout[sec(s)..day(s)] |_ External Temperature
|_ Start (date/time) of tariff |_ Cold/Warm Temperature Limit F
|_ Duration of tariff (nn=01..11:min to day) |_ Cold/Worm Temperature Limit C
|_ Period of tariff [sec(s) to day(s)] |_ Cumul. count max power
Swap Identification:
This field is used for select the Swap mode of Identification Number.
Examples:
- Identification Number (Secondary Address): 12345678; Address Register 1000; Convert BCD in Integer Identification Num. not checked.
None Type 1
1000: 0x1234 1000: 0x5678
1001: 0x5678 1001: 0x1234
- Identification Number (Secondary Address): 12345678; Address Register 1000; Convert BCD in Integer Identification Num. checked.
None Type 1
1000: 0x00BC 1000: 0x614E
1001: 0x614E 1001: 0x00BC
To know the meaning of value read in the Modbus Re Scale field, you must follow this table (x = Value read in Modbus Re Scale):
Data type F:
7 6 5 4 3 2 1 0
2 2 2 2 2 2 2 2
15 14 13 12 11 0 9 8
2 2 2 2 2 21 2 2
23 22 21 0 19 18 17 16
2 2 2 22 2 2 2 2
31 30 29 28 27 26 25 24
2 2 2 2 2 2 2 2
Min (0 59);
Hour (0 23);
Day (1 31);
Month (1 12);
Year (0 99);
Time Invalid (0=Valid, 1=Invalid);
Summer Time (0=Standard Time, 1=Summer Time);
Reserved (0).
Data type G:
7 6 5 4 3 2 1 0
2 2 2 2 2 2 2 2
15 14 13 12 11 0 9 8
2 2 2 2 2 21 2 2
Day (1 31);
Month (1 12);
Year (0 99).
UPDATE DEVICE:
By pressing the Update Device button it is possible to load the created Configuration into the
device; and also the Firmware, if is necessary.
In order to load the parameters or update the firmware in the Converter, follow these
instructions:
Turn off the Device;
Connect the Null Modem Cable form your PC to the Converter;
Insert the Boot Jumper (For more info see Fig. 1,2,3,4);
Select the COM port and press the Connect button;
Turn on the device;
Check the BOOT Led. It must blink quickly (For more info see Fig. 1,2,3,4);
Press the Next button;
Select which operations you want to do. You can select only
Firmware, only Project or both of them;
Press the Execute update firmware button to start the upload;
When all the operations are OK turn off the device;
Disconnect the Boot jumper;
Disconnect the RS232 Cable;
Turn on the device.
Note:
When you install a new version of the software it is better if the first time you do the update of the Firmware in the HD67029M-232-
xxx or HD67029M-485-xxx device.
Warning:
If the Fig. 9 appears when you try to do the Update before require assistance try these points:
Check if the serial COM port selected is the correct one;
Check if the serial is connected between the PC and the device;
Try to repeat the operations for the updating;
If you are using a dongle try with a native COM port or change the dongle;
Try with another PC;
Try to restart the PC;
If you are using the program inside a Virtual Machine, try to use in the main
Operating System.
In the case of HD67029M-232 you have to use the software SW67029: www.adfweb.com/download/filefold/SW67029.zip.
In the case of HD67029M-232-40, HD67029M-232-80, HD67029M-232-160, HD67029M-232-250 you have to use the software
SW67029 40 80 160 250: www.adfweb.com/download/filefold/SW67029_40_80_160_250.zip.
In the case of HD67029M-485 you have to use the software SW67029: www.adfweb.com/download/filefold/SW67029.zip.
In the case of HD67029M-485-40, HD67029M-485-80, HD67029M-485-160, HD67029M-485-250 you have to use the software
SW67029 40 80 160 250: www.adfweb.com/download/filefold/SW67029_40_80_160_250.zip.
RS232:
The connection from RS232 socket to a serial port (example one from a personal computer) must be made with a NULL MODEM cable (a
serial cable where the pins 2 and 3 are crossed).
It is recommended that the RS232C Cable not exceed 15 meters.
M-BUS:
A two wire standard telephone cable (JYStY N*2*0.8 mm) is used as the transmission medium for the M-Bus. The maximum distance
between a slave and the repeater is 350m; this length corresponds to a cable resistance of up 29. This distance applies for the standard
configuration having Baud rates between 300 and 9600 Baud, and a maximum of 250 slaves. The maximum distance can be increased by
limiting the Baud rate and using fewer slaves, but the bus voltage in the space state must at no point in a segment fall below 12V, because
of the remote powering of the slaves. In the standard configuration the total cable length should not exceed 1000m, in order to meet the
requirement of a maximum cable capacitance of 180nF. (Taken from M-Bus specifics)
MECHANICAL DIMENSIONS:
Figure 11: Mechanical dimensions scheme for HD67029M-232 Figure 12: Mechanical dimensions scheme for HD67029M-232-40,
HD67029M-485-80
Figure 13: Mechanical dimensions scheme for HD67029M-485 Figure 14: Mechanical dimensions scheme for HD67029M-485-40,
HD67029M-485-80
ADFweb.com Srl IT31010 Mareno Treviso INFO: www.adfweb.com Phone +39.0438.30.91.31
User Manual M-Bus Master / Modbus Slave
Document code: MN67029_ENG Revision 2.053 Page 29 of 33
Industrial Electronic Devices
Figure 15: Mechanical dimensions scheme for HD67029M-232-160 Figure 16: Mechanical dimensions scheme for HD67029M-232-250
Figure 17: Mechanical dimensions scheme for HD67029M-485-160 Figure 18: Mechanical dimensions scheme for HD67029M-485-250
ORDERING INFORMATIONS:
Device Family
HD67029: M-Bus Master / Modbus Slave - Converter
Order Code: HD67029M-232-20 - M-Bus Master / Modbus Slave (RS232) - Converter (up to 20 slaves connected to M-Bus)
Order Code: HD67029M-232-40 - M-Bus Master / Modbus Slave (RS232) - Converter (up to 40 slaves connected to M-Bus)
Order Code: HD67029M-232-80 - M-Bus Master / Modbus Slave (RS232) - Converter (up to 80 slaves connected to M-Bus)
Order Code: HD67029M-232-160 - M-Bus Master / Modbus Slave (RS232) - Converter (up to 160 slaves connected to M-Bus)
Order Code: HD67029M-232-250 - M-Bus Master / Modbus Slave (RS232) - Converter (up to 250 slaves connected to M-Bus)
Order Code: HD67029M-485-20 - M-Bus Master / Modbus Slave (RS485) - Converter (up to 20 slaves connected to M-Bus)
Order Code: HD67029M-485-40 - M-Bus Master / Modbus Slave (RS485) - Converter (up to 40 slaves connected to M-Bus)
Order Code: HD67029M-485-80 - M-Bus Master / Modbus Slave (RS485) - Converter (up to 80 slaves connected to M-Bus)
Order Code: HD67029M-485-160 - M-Bus Master / Modbus Slave (RS485) - Converter (up to 160 slaves connected to M-Bus)
Order Code: HD67029M-485-250 - M-Bus Master / Modbus Slave (RS485) - Converter (up to 250 slaves connected to M-Bus)
ACCESSORIES:
Order Code: APW040 - Power Supply for M-Bus Master device that supports up to 40 Slaves
Order Code: APW080 - Power Supply for M-Bus Master device that supports up to 80 Slaves
Order Code: APW160 - Power Supply for M-Bus Master device that supports up to 160 Slaves
Order Code: APW250 - Power Supply for M-Bus Master device that supports up to 250 Slaves
Order Code: AC34107 - Null Modem Cable Fem/Fem DSub 9 Pin 1,5 m
Order Code: AC34114 - Null Modem Cable Fem/Fem DSub 9 Pin 5 m
DISCLAIMER
All technical content within this document can be modified without notice. The content of the document content is a recurring audit.
For losses due to fire, earthquake, third party access or other accidents, or intentional or accidental abuse, misuse, or use under abnormal
conditions repairs are charged to the user. ADFweb.com S.r.l. will not be liable for accidental loss of use or inability to use this product, such
as loss of business income. ADFweb.com S.r.l. shall not be liable for consequences of improper use.
WEEE INFORMATION
Disposal of old electrical and electronic equipment (as in the European Union and other European countries with separate
collection systems).
This symbol on the product or on its packaging indicates that this product may not be treated as household rubbish. Instead, it
should be taken to an applicable collection point for the recycling of electrical and electronic equipment. If the product is disposed
correctly, you will help prevent potential negative environmental factors and human health, which could otherwise be caused by
inappropriate disposal. The recycling of materials will help to conserve natural resources. For more information about recycling this
product, please contact your local city office, your household waste disposal service or the shop where you purchased the product.
CE MARKING
The product conforms with the essential requirements of the applicable EC directives.
For fast and easy technical support for your ADFweb.com SRL products, consult our internet support at www.adfweb.com.
Otherwise contact us at the address [email protected]
RETURN POLICY:
If while using your product you have any problem and you wish to exchange or repair it, please do the following:
1) Obtain a Product Return Number (PRN) from our internet support at www.adfweb.com. Together with the request, you need to provide detailed information
about the problem.
2) Send the product to the address provided with the PRN, having prepaid the shipping costs (shipment costs billed to us will not be accepted).
If the product is within the warranty of twelve months, it will be repaired or exchanged and returned within three weeks. If the product is no longer under warranty,
you will receive a repair estimate.