Re 500-SD PDF
Re 500-SD PDF
Re 500-SD PDF
Epoxy Adhesive
Anchor System
Code compliance
with Strength Design
performance.
HIT-RE 500-SD Epoxy
Adhesive Anchor System
The Hilti HIT-RE 500-SD Epoxy Adhesive Anchor is a revolutionary new system
designed to meet the most stringent standards of the latest building codes. This
high performing anchor system can be used in cracked or un-cracked concrete and
high seismic conditions for anchoring applications with a standard Hilti HAS Rod.
Additionally, HIT-RE 500-SD can be used in the same conditions with rebar for
dowelling and structural reinforcement.
Hilti HIT-RE 500-SD is compliant with all current building codes in the United States
and is versatile enough for virtually any application. .
The industrys first adhesive anchor to be qualified for use under the 2003/2006
IBC, offering designers strength design solutions for anchors and rebar.
High seismic design category, cracked or un-cracked concrete, IBC 2003, IBC
2006 and 1997 UBC You are covered for virtually any application anywhere.
Reliability
Hilti HIT-RE 500-SD is also available with the HIT PROFI installation kits for a
simple and reliable installations on every project even the most challenging
applications.
Performance
Hilti raises the bar once again with industry-leading bond strength
performance.
The latest building codes require stringent testing of anchors intended for use
in cracked concrete Hilti HIT-RE 500-SD meets these requirements with
ease using a standard threaded rod no special elements required.
2 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
HIT-RE 500-SD Epoxy Adhesive Anchor
Dispensers
Battery Powered
Item No. Description ED 3500 2.0 Ah Kit
3425363 ED 3500 2.0 Ah Kit
Includes dispenser, 2.0-Ah NiCd battery, C 7/24 standard charger and accessories in an impact-
resistant plastic tool box
273676 ED 3500 Dispenser
Includes dispenser only in cardboard box
340888 SFB 121 2.0-Ah NiCd Battery for ED 3500
378449 C 7/24 Standard Charger for ED 3500 Foil Pack Holder
3426080 HIT-RE 500-SD (16.9 fl oz/500 ml)
Includes 5 MC and ED 3500 Dispenser 2.0 Ah Kit
3433546 HIT-RE 500-SD (16.9 fl oz/500 ml)
Includes 2 MC and MD 2500 Dispenser
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 3
Adhesive Anchoring Systems
4 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
D.4.1.2 In Eq. (D-1) and (D-2), Nn and Aa0 With n as the number of tension-loaded
Vn are the lowest design strengths adhesive anchors in a group.
determined from all appropriate failure where
k,max,uncr = kc,cr
hef . fc (D-14m)
modes. Nn is the lowest design strength Ana is the projected area of the failure p.d
in tension of an anchor or group of surface for the anchor or group of D.5.3.11 The modification factor for
anchors as determined from anchors that shall be approximated as eccentrically loaded adhesive anchor
consideration of Nsa, either Na or Nag and the base of the rectilinear geometrical groups is
either Ncb or Ncbg. Vn is the lowest design figure that results from projecting the 1 1.0
cec,Na = (D-14n)
strength in shear of an anchor or a group failure surface outward a distance from 2e'n
1 +
of anchors as determined from the centerlines of the anchor, or in the Scr,Na
consideration of: Vsa, either Vcb or Vcbg, and case of a group of anchors, from a line s
Eq. (D-14n) is valid for e'N
2
either Vcp or Vcpg. through a row of adjacent anchors. Ana
shall not exceed nAna0 where n is the If the loading on an anchor group is
D.4.1.4 For adhesive anchors
number of anchors in tension in the such that only some anchors are in
installed overhead and subjected to
group. (Refer to ACI 318 Figures tension, only those anchors that are in
tension resulting from sustained loading,
RD.5.2.1a and RD.5.2.1b and replace tension shall be considered when
Eq. (D-1) shall also be satisfied taking Nn
the terms 1.5hef and 3.0hef with ccr,Na and determining the eccentricity e'N for use in
= 0.75 Na for single anchors and Nn =
scr,Na, respectively.) Eq. (D-14n).
0.75 Nag for groups of anchors, whereby
Nua is determined from the sustained ANa0 is the projected area of the failure In the case where eccentric loading
load alone, e.g., the dead load and that surface of a single anchor without the exists about two orthogonal axes, the
portion of the live load acting that may influence of proximate edges in modification factor cec,Na shall be
be considered as sustained. Where accordance with Eq. (D-14c): computed for each axis individually and
shear loads act concurrently with the 2 the product of these factors used as
sustained tension load, interaction of ( )
ANa0 = scr,Na (D-14c) cec,Na in Eq. (D-14b).
tension and shear shall be checked in with D.5.3.12 The modification factor for
accordance with Section D.4.1.3.
scr,Na = as given by Eq. (D-14h) the edge effects for single adhesive
1 ACI 318-02 may also be used. The section references and terminology are different from those given in this report.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 5
Adhesive Anchoring Systems
6 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
(borehole)
Condition
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 7
Adhesive Anchoring Systems
Minimum Minimum
Reduction
THREADED ROD SPECIFICATION specified specified yield f /f Elongation, Specification for nuts6
of Area,
ultimate strength 0.2% uta ya min. %5
min. %
strength futa offset fya
ASTM A 1932 Grade B7 psi 125,000 105,000
1.19 16 50 ASTM A 563 Grade DH
2-1/2 in. ( 64 mm) (MPa) (862) (724)
ASTM F 568M3 Class 5.8
MPa 500 400 1.25 10 35 DIN 934 (8-A2K)
M5 (1/4 in.) to M24 (1 in.)
(psi) (72,500) (58,000) ASTM A 563 Grade DH7
(equivalent to ISO 898-1)
MPa 800 640
ISO 898-14 Class 8.8 1.25 12 52 DIN 934 (8-A2K)
(psi) (116,000) (92,800)
1 Hilti HIT-RE 500-SD may be used in conjunction with all grades of continuously threaded carbon steel rod (all-thread) that conform to the code and that have thread
characteristics comparable with ANSI B1.1 UNC Coarse Thread Series or ANSI B1.13M M Profile Metric Thread Series. Values for threaded rod types and associated nuts
supplied by Hilti are provided here.
2 Standard Specification for Alloy-Steel and Stainless Steel Bolting Materials for High-Temperature Service
3 Standard Specification for Carbon and Alloy Steel Externally Threaded Metric Fasteners
4 Mechanical properties of fasteners made of carbon steel and alloy steel Part 1: Bolts, screws and studs
5 Based on 2-in. (50 mm) gauge length except for A193 and A449, which are based on a gauge length of 4D and ISO 898 which is based on 5D.
6 Nuts of other grades and styles having specified proof load stresses greater than the specified grade and style are also suitable. Nuts must have specified proof load
stresses equal to or greater than the minimum tensile strength of the specified threaded rod.
7 Nuts for fractional rods.
Minimum Minimum
THREADED ROD SPECIFICATION specified specified yield f /f Elongation, Reduction of Specification for nuts4
ultimate strength 0.2% uta ya min. % Area, min. %
strength futa offset fya
ASTM F 5932 CW1 (316) psi 100,000 65,000
1.54 20 - F 594
1/4 to 5/8 in. (MPa) (689) (448)
ASTM F 5932 CW2 (316) psi 85,000 45,000
1.89 25 - F 594
3/4 to 1-1/2 in.(MPa) (586) (310)
ISO 3506-13 A4-70 MPa 700 450
1.56 40 - ISO 4032
M8 M24 (psi) (101,500) (65,250)
ISO 3506-13 A4-50 MPa 500 210
2.00 40 - ISO 4032
M27 M30 (psi) (72,500) (30,450)
1 Hilti HIT-RE 500-SD may be used in conjunction with all grades of continuously threaded stainless steel rod (all-thread) that conform to the code and that have thread
characteristics comparable with ANSI B1.1 UNC Coarse Thread Series or ANSI B1.13M M Profile Metric Thread Series. Values for threaded rod types and associated
nuts supplied by Hilti are provided here.
2 Standard Steel Specification for Stainless Steel Bolts, Hex Cap Screws, and Studs
3 Mechanical properties of corrosion-resistant stainless steel fasteners Part 1: Bolts, screws and studs
4 Nuts of other grades and styles having specified proof load stresses greater than the specified grade and style are also suitable. Nuts must have specified proof load
stresses equal to or greater than the minimum tensile strength of the specified threaded rod.
8 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Table 5 TENSILE PROPERTIES OF COMMON BOLTS, CAP SCREWS AND STUDS FOR USE WITH HIS-N
AND HIS-RN INSERTS1,2
Minimum Minimum
Reduction
BOLT, CAP SCREW OR STUD specified specified yield f /f Elongation, Specification for nuts6
of Area,
SPECIFICATION ultimate strength 0.2% uta ya min.
min.
strength futa offset fya
psi 120,000 92,000
SAE J4293 Grade 5 1.30 14 35 SAE J995
(MPa) (828) (634)
psi 120,000 92,000 A 563 C, C3, D, DH,
ASTM A 3254 1/2 to 1-in. 1.30 14 35
(MPa) (828) (634) DH3 Heavy Hex
ASTM F A1935 Grade B8M
psi 110,000 95,000 1.16 15 45 F 5947
(AISI 316) for use with
(MPa) (759) (655)
HIS-RN
ASTM F A1935 Grade B8M
psi 125,000 100,000 1.25 12 35 F 5947
(AISI 316) for use with
(MPa) (862) (690)
HIS-RN
1 Minimum Grade 5 bolts, cap screws or studs should be used in conjunction with carbon steel HIS inserts.
2 Use only stainless steel bolts, cap screws or studs with HIS-R inserts.
3 Mechanical and Material Requirements for Externally Threaded Fasteners
4 Standard Specification for Structural Bolts, Steel, Heat Treated, 120/105 ksi Minimum Tensile Strength
5 Standard Specification for Alloy-Steel and Stainless Steel Bolting Materials for High-Temperature Service
6 Nuts must have specified minimum proof load stress equal to or greater than the specified minimum full-size tensile strength of the specified stud.
7 Nuts for stainless steel studs must be of the same alloy group as the specified stud.
Minimum Minimum
REINFORCING BAR SPECIFICATION specified ultimate specified yield
strength futa strength fya
psi 90,000 60,000
ASTM A 6151 Gr. 60
(MPa) (620) (414)
psi 60,000 40,000
ASTM A 6151 Gr. 40
(MPa) (414) (276)
MPa 550 500
DIN 4882 BSt 500
(psi) (79,750) (72,500)
MPa 540 400
CAN/CSA-G30.183 Gr. 400
(psi) (78,300) (58,000)
1 Standard Specification for Deformed and Plain Carbon Steel Bars for Concrete Reinforcement
2 Reinforcing steel; reinforcing steel bars; dimensions and masses
3 Billet-Steel Bars for Concrete Reinforcement
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 9
Adhesive Anchoring Systems
Nsa
Nominal strength as governed (kN) (34.5) (63.1) (100.5) (126.5) (174.6) (229.0) (366.4)
by steel strength lb 3,875 8,514 13,560 17,059 23,546 30,890 49,423
Vsa
(kN) (17.2) (.37.9) (60.3) (75.9) (104.7) (137.4) (219.8)
Reduction for seismic shear aV,seis - 0.70
Strength reduction factor f for tension2 f - 0.75
Strength reduction factor f for shear2 f - 0.65
For SI: 1 inch = 25.4 mm, 1 lbf = 4.448 N, 1 psi = 0.006897 MPa
For pound-inch units: 1 mm = 0.03937 inches, 1 N = 0.2248 lbf, 1 MPa = 145.0 psi
1 Values provided for common rod material types based on published strengths and calculated in accordance with ACI 318-05 Eq. (D-3) and Eq. (D-20). Other material
specifications are admissible. Use nuts and washers appropriate for the rod strength.
2 For use with the load combinations of ACI 318-05 Section 9.2. See ACI 318-05 Section D.4.4.
10 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 11
Adhesive Anchoring Systems
12 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 13
Adhesive Anchoring Systems
by steel strength
kN 9.2 14.5 25.3 47.1 73.5 105.9 137.7 168.3
Vsa
(lb) (2,057) (3,260) (5,685) (10,588) (16,523) (23,807) (30,956) (37,835)
Reduction for seismic shear aV,seis - 0.70
Strength reduction factor f for tension2 f - 0.65
Strength reduction factor f for shear2 f - 0.60
kN 29.3 46.4 67.4 125.6 196.0 282.4 367.2 448.8
Nsa
Nominal strength as governed (lb) (6,582) (10,431) (15,161) (28,236) (44,063) (63,486) (82,550) (100,894)
ISO 898-1 Class 8.8
by steel strength
kN 14.6 23.2 40.5 75.4 117.6 169.4 220.3 269.3
Vsa
(lb) (3,291) (5,216) (9,097) (16,942) (26,438) (38,092) (49,530) (60,537)
Reduction for seismic shear aV,seis - 0.70
Strength reduction factor f for tension2 f - 0.65
Strength reduction factor f for shear2 f - 0.60
ISO 3506-1 Class A4 Stainless3
14 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 15
Adhesive Anchoring Systems
Water-saturated concrete
kws - 1.00 1.00 1.00 1.00 1.00 1.00 0.98 0.95
conditions
16 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 17
Adhesive Anchoring Systems
Table 15 STEEL DESIGN INFORMATION FOR FRACTIONAL HILTI HIS-N AND HIS-RN INSERTS1
18 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Table 16 CONCRETE BREAKOUT DESIGN INFORMATION FOR FRACTIONAL HILTI HIS-N AND HIS-RN INSERTS 1
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 19
Adhesive Anchoring Systems
k,cr
range A3
k,cr
range B3
20 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 21
Adhesive Anchoring Systems
22 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Table 20 CONCRETE BREAKOUT DESIGN INFORMATION FOR METRIC HILTI HIS-N AND HIS-RN INSERTS 1
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 23
Adhesive Anchoring Systems
k,cr
range A3
k,cr
range B3
Water-saturated concrete
kws - 1.00 1.00 1.00 0.99 0.97
conditions
24 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 25
Adhesive Anchoring Systems
Bar size
DESIGN INFORMATION Symbol Units
#3 #4 #5 #6 #7 #8 #9 #10
in. 3/8 1/2 5/8 3/4 7/8 1 1-1/8 1-1/4
Nominal bar diameter d
(mm) (9.5) (12.7) (15.9) (19.1) (22.2) (25.4) (28.6) (31.8)
in.2 0.11 0.2 0.31 0.44 0.6 0.79 1.0 1.27
Bar effective cross-sectional area Ase
(mm2) (71) (129) (200) (284) (387) (510) (645) (819)
lb 6,600 12,000 18,600 26,400 36,000 47,400 60,000 76,200
Nominal strength as Nsa
(kN) (29.4) (53.4) (82.7) (117.4) (160.1) (210.9) (266.9) (339.0)
governed by steel
lb 3,960 7,200 11,160 15,840 21,600 28,440 36,000 45,720
ASTM A 615 Gr. 40
strength
Vsa
(kN) (17.6) (32.0) (49.6) (70.5) (96.1) (126.5) (160.1) (203.4)
Reduction for seismic shear aV,seis - 0.70
Strength reduction factor
f - 0.75
f for tension2
Strength reduction factor
f - 0.65
f for shear2
lb 9,900 18,000 27,900 39,600 54,000 71,100 90,000 114,300
Nominal strength as Nsa
(kN) (44.0) (80.1) (124.1) (176.2) (240.2) (316.3) (400.4) (508.5)
governed by steel
ASTM A 615 Gr. 60
26 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Bar size
DESIGN INFORMATION Symbol Units
#3 #4 #5 #6 #7 #8 #9 #10
Effectiveness factor for in-lb 17
kc,cr
cracked concrete (SI) (7.1)
Effectiveness factor for in-lb 24
kc,uncr
un-cracked concrete (SI) (10)
in. 1-7/8 2-1/2 3-1/8 3-3/4 4-3/8 5 5-5/8 6-1/4
Minimum bar spacing smin
(mm) (48) (64) (79) (95) (111) (127) (143) (159)
in. 1-7/8 2-1/2 3-1/8 3-3/4 4-3/8 5 5-5/8 6-1/4
Minimum edge distance cmin
(mm) (48) (64) (79) (95) (111) (127) (143) (159)
in. hef + 1-1/4
Minimum member thickness hmin hef + 2d o
(mm) (hef + 30)
Critical edge distance splitting
cac - See Strength Design provisions above
(for un-cracked concrete)
Strength reduction factor for
tension, concrete failure f - 0.65
modes, Condition B2
Strength reduction factor for
shear, concrete failure f - 0.70
modes, Condition B2
For SI: 1 inch = 25.4 mm, 1 lbf = 4.448 N, 1 psi = 0.006897MPa
For pound-inch units: 1 mm = 0.03937 inches, 1 N = 0.2248 lbf, 1 MPa = 145.0 psi
1 For additional setting information, see installation instructions.
2 Values provided for post-installed anchors with category as determined from ACI 355.2 given for Condition B without supplementary reinforcement.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 27
Adhesive Anchoring Systems
Bar size
DESIGN INFORMATION Symbol Units
#3 #4 #5 #6 #7 #8 #9 #10
Characteristic bond psi 1,092 1,073 1,044 999 917 852 799 732
k,cr
strength and minimum (N/mm2) (7.5) (7.4) (7.2) (6.9) (6.3) (5.9) (5.5) (5.0)
Temperature range A3
anchor embedment in in. 2.43 2.81 3.14 3.44 3.71 4.00 4.50 5.00
cracked concrete hef,min
(mm) (62) (71) (80) (87) (94) (102) (114) (127)
Characteristic bond psi 2,264 2,236 2,142 2,067 2,002 1,946 1,899 1,862
k,uncr
strength and minimum (N/mm2) (15.6) (15.4) (14.8) (14.3) (13.8) (13.4) (13.1) (12.8)
anchor embedment in in. 2.43 2.81 3.14 3.44 3.71 4.00 4.50 5.00
un-cracked concrete hef,min
(mm) (62) (71) (80) (87) (94) (102) (114) (127)
Characteristic bond psi 444 431 379 345 316 294 276 260
k,cr
strength and minimum (N/mm2) (3.1) (3.0) (2.6) (2.4) (2.2) (2.0) (1.9) (1.8)
Temperature range B3
anchor embedment in in. 1.73 2.20 2.61 3.00 3.50 4.00 4.50 5.00
cracked concrete2 hef,min
(mm) (44) (56) (66) (76) (89) (102) (114) (127)
Characteristic bond psi 781 772 739 714 691 672 656 643
k,uncr
strength and minimum (N/mm2) (5.4) (5.3) (5.1) (4.9) (4.8) (4.6) (4.5) (4.4)
anchor embedment in in. 1.73 2.20 2.61 3.00 3.50 4.00 4.50 5.00
un-cracked concrete2 hef,min
(mm) (44) (56) (66) (76) (89) (102) (114) (127)
Dry concrete fd - 0.65 0.65 0.65 0.65 0.55 0.55 0.55 0.55
fws - 0.55 0.55 0.45 0.45 0.45 0.45 0.45 0.45
Permissible installation
Water-saturated
concrete kws - 1.00 1.00 1.00 1.00 1.00 0.99 0.97 0.94
conditions
28 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Table 26 BOND STRENGTH DESIGN INFORMATION FOR FRACTIONAL REINFORCING BARS IN HOLES
DRILLED WITH A CORE DRILL1,4
Bar size
DESIGN INFORMATION Symbol Units
#3 #4 #5 #6 #7 #8 #9 #10
Characteristic bond psi 1,740 1,703 1,553 1,441 1,356 1,282 1,226 1,169
Temperature
k,uncr
(N/mm2)
range A3
strength and minimum (12.0) (11.7) (10.7) (9.9) (9.4) (8.8) (8.4) (8.1)
anchor embedment in in. 2.43 2.81 3.14 3.44 3.71 4.00 4.50 5.00
un-cracked concrete hef,min
(mm) (62) (71) (80) (87) (94) (102) (114) (127)
Characteristic bond psi 601 588 536 497 468 442 423 404
Temperature
k,uncr
range B3
strength and minimum (N/mm2) (4.1) (4.1) (3.7) (3.4) (3.2) (3.1) (2.9) (2.8)
anchor embedment in in. 1.57 2.00 2.50 3.00 3.50 4.00 4.50 5.00
un-cracked concrete2 hef,min
(mm) (40) (51) (64) (76) (89) (102) (114) (127)
Dry concrete fd - 0.65 0.65 0.55 0.55 0.55 0.45 0.45 0.45
Permissible
installation
conditions
Water-saturated fws - 0.65 0.55 0.55 0.55 0.45 0.45 0.45 0.45
concrete kws - 1.00 1.00 1.00 1.00 1.00 0.95 0.91 0.88
For SI: 1 inch = 25.4 mm, 1 lbf = 4.448 N, 1 psi = 0.006897MPa
For pound-inch units: 1 mm = 0.03937 inches, 1 N = 0.2248 lbf, 1 MPa = 145.0 psi
1 Bond strength values correspond to concrete compressive strength range 2,500 psi fc 4,500 psi. For 4,500 psi fc 6,500 psi, tabulated characteristic bond
strength may be increased by 6%. For 6,500 psi fc 8,000 psi, tabulated characteristic bond strength may be increased by 10%.
2 Characteristic bond strengths are for sustained loads including dead and live loads. For short-term loads including wind and seismic, bond strengths may be increased
40%.
3 Temperature range A: Max. short term temperature = 110F (43C), max. long term temperature = 80F (26C).
Temperature range B: Max. short term temperature = 162F (72C), max. long term temperature = 110F (43C).
Short term elevated concrete temperatures are those that occur over brief intervals, e.g., as a result of diurnal cycling. Long term concrete temperatures are roughly
constant over significant periods of time.
4 Bond strength values applicable to SDC A and B only.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 29
Adhesive Anchoring Systems
Bar size
DESIGN INFORMATION Symbol Units
8 10 12 14 16 20 25 28 32
mm 8.0 10.0 12.0 14.0 16.0 20.0 25.0 28.0 32.0
Nominal bar diameter d
(in.) (0.315) (0.394) (0.472) (0.551) (0.630) (0.787) (0.984) (1.102) (1.260)
Bar effective cross-sectional mm2 50.3 78.5 113.1 153.9 201.1 314.2 490.9 615.8 804.2
Ase
area (in.2) (0.078) (0.122) (0.175) (0.239) (0.312) (0.487) (0.761) (0.954) (1.247)
kN 27.6 43.2 62.2 84.7 110.6 172.8 270.0 338.7 442.3
Nominal strength Nsa
(lb) (6,215) (9,711) (13,984) (19,034) (24,860) (38,844) (60,694) (76,135) (99,441)
as governed
DIN 488 BSt 550/500
by steel strength kN 16.6 25.9 37.3 50.8 66.4 103.7 162.0 203.2 265.4
Vsa
(lb) (3,729) (5,827) (8,390) (11,420) (14,916) (23,307) (36,416) (45,681) (59,665)
Reduction for seismic shear aV,seis - 0.70
Strength reduction
f - 0.65
factor f for tension2
Strength reduction
f - 0.60
factor f for shear2
For SI: 1 inch = 25.4 mm, 1 lbf = 4.448 N, 1 psi = 0.006897MPa
For pound-inch units: 1 mm = 0.03937 inches, 1 N = 0.2248 lbf, 1 MPa = 145.0 psi
1 Values provided for common rod material types based on published strengths and calculated in accordance with ACI 318-05 Eq. (D-3) and Eq. (D-20). Other material
specifications are admissible. Use nuts and washers appropriate for the rod strength.
2 For use with the load combinations of ACI 318-05 Section 9.2. See ACI 318-05 Section D.4.4.
Table 28 CONCRETE BREAKOUT DESIGN INFORMATION FOR EU METRIC REINFORCING BARS IN HOLES
DRILLED WITH A HAMMER DRILL AND CARBIDE BIT1
Bar size
DESIGN INFORMATION Symbol Units
8 10 12 14 16 20 25 28 32
Effectiveness factor SI 7.1
kc,cr
for cracked concrete (in-lb) (17)
Effectiveness factor SI 10
kc,uncr
for un-cracked concrete (in-lb) (24)
mm 40 50 60 70 80 100 125 140 160
Minimum bar spacing smin
(in.) (1.6) (2) (2.4) (2.8) (3.1) (3.9) (4.9) (5.5) (6.3)
mm 40 50 60 70 80 100 125 140 160
Minimum edge distance cmin
(in.) (1.6) (2) (2.4) (2.8) (3.1) (3.9) (4.9) (5.5) (6.3)
Minimum member mm hef+ 30
hmin hef + 2d o
thickness (in.) (hef + 1-1/4)
Critical edge distance splitting
cac - See Strength Design provisions above
(for un-cracked concrete)
Strength reduction factor for
tension, concrete failure f - 0.65
modes, Condition B2
Strength reduction factor for
shear, concrete failure modes, f - 0.70
Condition B2
For SI: 1 inch = 25.4 mm, 1 lbf = 4.448 N, 1 psi = 0.006897MPa
For pound-inch units: 1 mm = 0.03937 inches, 1 N = 0.2248 lbf, 1 MPa = 145.0 psi
1 For additional setting information, see installation instructions.
2 Values provided for post-installed anchors with category as determined from ACI 355.2 given for Condition B without supplementary reinforcement.
30 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Bar size
DESIGN INFORMATION Symbol Units
8 10 12 14 16 20 25 28 32
Characteristic bond N/mm2 7.5 7.5 7.5 7.4 7.2 6.7 5.9 5.6 5.0
k,cr
strength and minimum (psi) (1,092) (1,092) (1,092) (1,068) (1,044) (972) (862) (806) (732)
Temperature range A3
Characteristic bond N/mm2 15.6 15.6 15.6 15.2 14.8 14.1 13.5 13.2 12.8
k,uncr
strength and minimum (psi) (2,264) (2,264) (2,264) (2,198) (2,142) (2,039) (1,955) (1,908) (1,862)
anchor embedment in mm 57 63 69 75 80 89 100 112 128
un-cracked concrete hef,min
(in.) (2.23) (2.49) (2.73) (2.95) (3.15) (3.52) (3.94) (4.41) (5.04)
Characteristic bond N/mm2 3.1 3.1 3.1 2.8 2.6 2.3 2.1 1.9 1.8
k,cr
strength and minimum (psi) (444) (444) (444) (410) (379) (336) (298) (278) (260)
Temperature range B3
Characteristic bond N/mm2 5.4 5.4 5.4 5.2 5.1 4.9 4.7 4.5 4.4
k,uncr
strength and minimum (psi) (781) (781) (781) (759) (739) (704) (675) (659) (643)
anchor embedment in mm 40 46 53 60 67 80 100 112 128
un-cracked concrete2 hef,min
(in.) (1.57) (1.80) (2.10) (2.37) (2.62) (3.15) (3.94) (4.41) (5.04)
Dry concrete fd - 0.65 0.65 0.65 0.65 0.65 0.55 0.55 0.55 0.55
fws
Permissible installation
Water-saturated - 0.55 0.55 0.55 0.45 0.45 0.45 0.45 0.45 0.45
concrete kws - 1.00 1.00 1.00 1.00 1.00 1.00 0.97 0.94 0.94
conditions
fwf - 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45
Water-filled hole
kwf - 1.00 1.00 1.00 0.96 0.93 0.87 0.82 0.79 0.79
Underwater fuw - 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45 0.45
application kuw - 0.95 0.95 0.94 0.94 0.93 0.92 0.92 0.91 0.91
For SI: 1 inch = 25.4 mm, 1 lbf = 4.448 N, 1 psi = 0.006897MPa
For pound-inch units: 1 mm = 0.03937 inches, 1 N = 0.2248 lbf, 1 MPa = 145.0 psi
1 Bond strength values correspond to concrete compressive strength range 2,500 psi fc 4,500 psi. For 4,500 psi fc 6,500 psi, tabulated characteristic bond strength
may be increased by 6%. For 6,500 psi fc 8,000 psi, tabulated characteristic bond strength may be increased by 10%.
2 Characteristic bond strengths are for sustained loads including dead and live loads. For short-term loads including wind and seismic, bond strengths may be increased 40%.
3 Temperature range A: Max. short term temperature = 110F (43C), max. long term temperature = 80F (26C).
Temperature range B: Max. short term temperature = 162F (72C), max. long term temperature = 110F (43C).
Short term elevated concrete temperatures are those that occur over brief intervals, e.g., as a result of diurnal cycling. Long term concrete temperatures are roughly constant
over significant periods of time.
4 For structures assigned to SDC C, D, E or F, bond strength values shall be multiplied by aN,seis = 0.65.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 31
Adhesive Anchoring Systems
Bar size
DESIGN INFORMATION Symbol Units
8 10 12 14 16 20 25 28 32
N/mm2 12.0 12.0 12.0 11.3 10.7 9.7 8.9 8.5 8.1
Temperature
strength and minimum (psi) (1,740) (1,740) (1,740) (1,637) (1,553) (1,413) (1,291) (1,235) (1,169)
anchor embedment in mm 56 63 69 75 80 89 100 112 128
un-cracked concrete hef,min
(in.) (2.19) (2.49) (2.73) (2.95) (3.15) (3.52) (3.94) (4.41) (5.04)
N/mm2 4.1 4.1 4.1 3.9 3.7 3.4 3.1 2.9 2.8
Temperature
strength and minimum (psi) (601) (601) (601) (565) (536) (488) (446) (426) (404)
anchor embedment mm 40 41 48 56 64 80 100 112 128
in un-cracked concrete2 hef,min (in.) (1.57) (1.61) (1.89) (2.20) (2.52) (3.15) (3.94) (4.41) (5.04)
Dry concrete fd - 0.65 0.65 0.65 0.55 0.55 0.55 0.45 0.45 0.45
Permissible
installation
conditions
Water-saturated fws - 0.55 0.55 0.55 0.45 0.45 0.45 0.45 0.45 0.45
concrete kws - 1.0 1.0 1.0 1.0 1.0 1.0 0.92 0.88 0.88
For SI: 1 inch = 25.4 mm, 1 lbf = 4.448 N, 1 psi = 0.006897MPa
For pound-inch units: 1 mm = 0.03937 inches, 1 N = 0.2248 lbf, 1 MPa = 145.0 psi
1 Bond strength values correspond to concrete compressive strength range 2,500 psi fc 4,500 psi. For 4,500 psi fc 6,500 psi, tabulated characteristic bond strength
may be increased by 6%. For 6,500 psi fc 8,000 psi, tabulated characteristic bond strength may be increased by 10%.
2 Characteristic bond strengths are for sustained loads including dead and live loads. For short-term loads including wind and seismic, bond strengths may be increased 40%.
3 Temperature range A: Max. short term temperature = 110F (43C), max. long term temperature = 80F (26C).
Temperature range B: Max. short term temperature = 162F (72C), max. long term temperature = 110F (43C).
Short term elevated concrete temperatures are those that occur over brief intervals, e.g., as a result of diurnal cycling. Long term concrete temperatures are roughly constant
over significant periods of time.
4 Bond strength values applicable to SDC A and B only.
Bar size
DESIGN INFORMATION Symbol Units
10 M 15 M 20 M 25 M 30 M
mm 11.3 16.0 19.5 25.2 29.9
Nominal bar diameter d
(in.) (0.445) (0.630) (0.768) (0.992) (1.177)
Bar effective cross-sectional mm2 100.3 201.1 298.6 498.8 702.2
Ase
area (in.2) (0.155) (0.312) (0.463) (0.773) (1.088)
kN 54.2 108.6 161.3 269.3 379.2
Nominal strength Nsa
(lb) (12,175) (24,408) (36,255) (60,548) (85,239)
as governed by
steel strength kN 32.5 65.1 96.8 161.6 227.5
Vsa
(lb) (7,305) (14,645) (21,753) (36,329) (51,144)
CSA G30
32 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Bar size
DESIGN INFORMATION Symbol Units
10 M 15 M 20 M 25 M 30 M
Effectiveness factor for SI 7.1
kc,cr
cracked concrete (in-lb) (17)
Effectiveness factor for SI 10
kc,uncr
un-cracked concrete (in-lb) (24)
mm 57 80 98 126 150
Minimum bar spacing smin
(in.) (2.2) (3.1) (3.8) (5.0) (5.9)
mm 57 80 98 126 150
Minimum edge distance cmin
(in.) (2.2) (3.1) (3.8) (5.0) (5.9)
mm hef + 30
Minimum member thickness hmin hef + 2d o
(in.) (hef + 1-1/4)
Critical edge distance
cac - See Strength Design provisions above
splitting (for un-cracked concrete)
Strength reduction factor
for tension, concrete failure f - 0.65
modes, Condition B2
Strength reduction factor
for shear, concrete failure f - 0.70
modes, Condition B2
For SI: 1 inch = 25.4 mm, 1 lbf = 4.448 N, 1 psi = 0.006897MPa
For pound-inch units: 1 mm = 0.03937 inches, 1 N = 0.2248 lbf, 1 MPa = 145.0 psi
1 For additional setting information, see installation instructions.
2 Values provided for post-installed anchors with category as determined from ACI 355.2 given for Condition B without supplementary reinforcement.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 33
Adhesive Anchoring Systems
Bar size
DESIGN INFORMATION Symbol Units
10 M 15 M 20 M 25 M 30 M
34 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Adhesive Anchoring Systems
Bar size
DESIGN INFORMATION Symbol Units
10 M 15 M 20 M 25 M 30 M
N/mm2 12.0 10.7 9.9 8.9 8.3
Temperature
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 35
Installation Instructions
Installation Instructions
Adhesive anchoring system for fastenings in normal Method 2 for water filled boreholes, submerged concrete
weight concrete or diamond cored boreholes:
Prior to use of product follow instructions for use and Flush hole 2 times by inserting a water hose (water-line
pressure) to the back of the borehole until water runs clear.
recommended safety precautions.
Brush 2 times with the specified brush size (brush =
Check expiration date: See expiration date imprint on
borehole ) by inserting the round steel brush to the back of
foilpack manifold. (Month/Year). Do not use expired product. the borehole with a twisting motion and removing it. The
Foil pack temperature: Must be between 41F and 104F brush should resist insertion into the borehole if not, the
(5C - 40C) when in use. brush is too small and must be replaced with the proper brush
Base material temperature at time of installation: Must be diameter.
between 41F and 110F (5C - 43C). Flush again 2 times until water runs clear.
Instructions for transport and storage: Keep in a cool, dry Important! For diamond cored boreholes and if a dry
and dark place between 41F and 77F (5C - 25C). borehole is required for injection (e.g. water flows into
cleaned borehole), continue with borehole cleaning as
Material Safety Data Sheet: Review the MSDS before use.
described by methode 1. Remove all standing water
Installation Instructions: Follow the pictograms 1-14 for the completely (i.e. vacuum, compressed air or other appropriate
sequence of operations and refer to tables 1-3 for setting details. For procedure). To attain a dried borehole, a Hilti HIT-DL air nozzle
any application not covered by this document (e.g. h ef beyond attachment is recommended for borehole depth up to 10 inch
values specified in setting details), contact Hilti. (250 mm) and required for borehole depth > 10 inch (250 mm).
Installation flow Chart The borehole must be free of dust, debris, ice, oil, grease
Hammer Drilling Diamond Coring Hammer Drilling and other contaminants prior to adhesive injection.
Check Water Water
Inadequate borehole cleaning = poor load values
borehole Dry saturated Dry saturated Water-filled Submerged
conditions 5. Insert foil pack in foil pack holder. Never use damaged foil
Borehole packs and/or damaged or unclean foil pack holders.
Cleaning Cleaning Cleaning
Cleaning method 1 method 2+1 method 2
instructions 6. Tightly attach Hilti HIT-RE-M mixer to foil pack manifold.
Borehole
Attach new mixer prior to dispensing a new foil pack (snug fit).
Clean and dry Clean and water-filled
conditions Do not modify the mixer in any way. Make sure the mixing
element is in the mixer. Use only the mixer supplied with the
Installation Horizontal All
direction and vertical
Overhead directions adhesive.
7. Insert foil pack holder with foil pack into HIT-dispenser.
Drilling ? 10 inch > 10 inch All drilling All drilling Push release trigger, retract plunger and insert foil pack holder
depth (250 mm) (250 mm) depth depth
into the appropriate Hilti dispenser.
Injection HIT-SZ/IP HIT-SZ/IP HIT-SZ/IP HIT-SZ/IP 8. Discard initial adhesive. The foil pack opens automatically as
instructions not required recommended required required
dispensing is initiated. Depending on the size of the foil pack an
1. Drill hole normal to the surface with a hammer drill set in initial amount of adhesive has to be discarded. See pictogram 8
rotation-hammer mode using an appropriately sized carbide for discard quantities. If a new mixer is installed onto a
drill bit, or with a core rig and an appropriately sized diamond previously-opened foil pack, the first trigger pulls must also be
core bit, to the required embedment depth. See tables discarded as described above. For each new foil pack a new
describing setting details. (Drill bits must conform to ANSI mixer must be used.
B212-1994.) 9-10. Inject adhesive from the back of the borehole without
2-4. Clean hole: Cleaning method has to be decided based on forming air voids:
drilling method and borehole conditions (see flow chart above). Verify if borehole conditions have changed (e.g. water in the
Just before setting an anchor/rebar, the borehole must be free borehole) after cleaning. If yes, repeat cleaning according
of dust and debris by one of the following methods: points 2 - 4.
Method 1 for dry or water saturated concrete (refer to Inject the adhesive starting at the back of the borehole (use
pictograms): the extension for deep boreholes), slowly withdraw the mixer
Blow from the back of the borehole with oil-free compressed with each trigger pull. Fill holes approximately 2/3 full, or as
air (min. 90psi at 3.5 CFM (6 bar at 6 m3/h)) fully retracting the required to ensure that the annular gap between the anchor/
air extension 2 times until return air stream is free of rebar and the concrete is completely filled with adhesive
noticeable dust. along the embedment length. After injection is completed,
depressurize the dispenser by pressing the release trigger.
Brush 2 times with the specified brush size (brush =
This will prevent further adhesive discharge from the mixer.
borehole ) by inserting the round steel brush to the back of
the borehole in a twisting motion and removing it. The brush Piston plug injection HIT-SZ/IP recommended for
should resist insertion into the borehole if not, the brush is borehole depth > 10 inch/250 mm. Waterfilled boreholes
too small and must be replaced with the proper brush or submerged concrete, and overhead installation the
diameter. piston plugs are required. Assemble HIT-RE-M mixer,
extension(s) and appropriately sized piston plug HIT-SZ/IP.
Blow again with compressed air 2 times until return air stream
Insert piston plug to back of the borehole and inject adhesive
is free of noticeable dust.
36 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Installation Instructions
Installation Instructions
as described in the injection method
above. During injection the piston
plug will be naturally extruded out of or
the borehole by the adhesive
pressure.
11. Insert anchor/rebar into borehole.
Mark and set anchor/rebar to the
required embedment depth. Before
use, verify that the anchor/rebar is dry
and free of oil and other contaminants.
To ease installation, anchor/rebar may
be slowly twisted as they are inserted.
After installing an anchor/rebar, the
annular gap must be completely filled
with adhesive. If the borehole is not
completely filled along the embedment
depth the installation should be
rejected. Hilti should be contacted for
further information.
Attention! For overhead applications
take special care when inserting the
anchor/rebar. Excess adhesive will be
forced out of the borehole take
appropriate steps to prevent it from
falling onto the installer. Position the
anchor/rebar and secure it from
moving/falling during the curing time
(e.g. wedges). Observe the gel time t
gel, which varies according to
temperature of base material. Minor or
adjustments to the anchor/rebar
position may be performed during the
gel time. See table.
12. Do not disturb the anchor/rebar
once the gel time t gel has elapsed
until t cure, ini has passed.
13. Preparation work may continue for
rebar applications. Between t cure,
ini and t cure, full the adhesive has
a limited load bearing capacity, do not
apply a torque or load on the
anchor/rebar during this time.
14. Apply load/torque after t cure, full
has passed, and the fixture to be
attached has been positioned.
Partly used foil packs must be used up
within four weeks. Leave the mixer attached
to the foil pack manifold and store under the
recommended storage conditions. If reused, F C twork / tgel tcure, ini tcure, full Time
attach a new mixer and discard theinitial
41 5 2.5 hrs 18 hrs 72 hrs
quantity of anchor adhesive as described by
point 8. 50 10 2 hrs 12 hrs 48 hrs
59 15 1.5 hrs 8 hrs 24 hrs
68 20 30 min 6 hrs 12 hrs
86 30 20 min 4 hrs 8 hrs
104 40 12 min 2 hrs 4 hrs
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 37
Installation Instructions
Installation Instructions
Table 1 Setting Details of Hilti HIT-RE 500-SD with threaded rod
Table 2 Setting Details of Hilti HIT-RE 500-SD with HIS-N and HIS-RN Inserts
38 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Installation Instructions
Installation Instructions
Table 3 Setting Details of Hilti HIT-RE 500-SD with reinforcement bars
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 39
Material Safety Data Sheet
PHYSICAL DATA
Appearance: A: Gray; B: red / paste. VOC Content: 0.0 g/l
Amine-like odor.
Boiling Point: Approx. 212 F Vapor Pressure: Not determined.
Vapor Density: (air = 1) Not determined. Odor Threshold: Not determined.
Evaporation Rate: Not applicable. Solubility in Water: Insoluble.
Specific Gravity: 1.5 pH: 11 (Part B with 1:1 water)
FIRE AND EXPLOSION HAZARD DATA
Flash Point: > 200 F Flammable Limits: Not applicable.
Extinguishing Media: Water, CO2, Dry Chemical, Foam.
Special Fire Fighting A NIOSH-approved self-contained breathing apparatus (SCBA) should be worn when
Procedures: fighting fires involving chemicals.
Unusual Fire and Explosion Hazards: None known. Product serves as a fire stopping material.
REACTIVITY DATA
Flash Point: > 200 F Flammable Limits: Not applicable.
Extinguishing Media: CO2, Dry Chemical, Foam, Water Spray.
Special Fire Fighting Procedures: A self-contained breathing apparatus should be worn when fighting fires involving chemicals.
Unusual Fire and Explosion Hazards: None known. Thermal decomposition products can be formed including Hazards: COX,
NOX, water and carbon.
40 Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07
Material Safety Data Sheet
The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or
warranty of any kind expressed or implied is made with respect to the information provided.
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en espaol 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I RE 500-SD Submittal Information 7/07 41
In the US: In Canada:
P.O. Box 21148 Tulsa, OK 74121 6790 Century Avenue, Suite 300
Customer Service: 1-800-879-8000 CDN-Mississauga, Ontario L5N 2V8
en espaol: 1-800-879-5000 Customer Service: 1-800-363-4458
Fax: 1-800-879-7000 Fax: 1-800-363-4459
www.us.hilti.com www.hilti.ca
The data contained in this literature was current as of the date of publication. Updates and changes may be made
based on later testing. If verification is needed that the data is still current, please contact the Hilti Technical Support
Specialists at 1-800-879-8000. All published load values contained in this literature represent the results of testing by
Hilti or test organizations. Local base materials were used. Because of variations in materials, on-site testing is
necessary to determine performance at any specific site. Laser beams represented by red lines in this publication.
Printed in the United States