0% found this document useful (0 votes)
187 views

Design of Rectangular Footing - 1

The document provides the design of a rectangular footing to support a 600mm x 600mm column. Key details include: - The footing must support a total deadload of 1500KN and liveload of 1200KN. - Dimensions are limited to a width of 3m and depth of 2m below ground. - Calculations determine the footing should be 4.7m x 3m x 0.7m thick. - Reinforcement requirements are determined to be 21 bars along the longitudinal direction and 23 bars along the transverse direction, both with a diameter of 25mm.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
187 views

Design of Rectangular Footing - 1

The document provides the design of a rectangular footing to support a 600mm x 600mm column. Key details include: - The footing must support a total deadload of 1500KN and liveload of 1200KN. - Dimensions are limited to a width of 3m and depth of 2m below ground. - Calculations determine the footing should be 4.7m x 3m x 0.7m thick. - Reinforcement requirements are determined to be 21 bars along the longitudinal direction and 23 bars along the transverse direction, both with a diameter of 25mm.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

DESIGN OF RECTANGULAR FOOTING

Problem 9.2A
A 600 mm x 600 mm column carries a toatl liveload of 1200 KN and a total deadload of 1500 KN.
The column is to be supported by a rectangular spread footing whose width is limited to 3 m and
whose bottom is 2 m below the ground surface.allowable soil bearing capacity at the base of the
footing is 230 KPa. Unit weight of soil above footing is 16 KN/cu. m3 and unit weight of concrete is
23.50 KN/ cu. m3. Assume fc' = 28 MPa and fy = 275 MPa.Use 25 mm main bars.

Given :
Column Dimensions: Cx 600 mm Cy 600 mm
Df 2.00 m qall 230 KPa
Loads : DL 1500 KN LL 1200 KN B 3.0 m
fy 275 MPa fc 28 MPa
KN KN
soil 16 conc 23.50 Main bar diameter b 28 mm
3 3
m m Concrete Cover Cc 75 mm

Initial Estimate of Footing Total Thickness

Total Thickness t:
t 0.20 B 1000 Cc t 675 mm t 700 mm
Effective Soil Bearing Capacity

soil Df
t t
q eff q all conc
1000 1000

qeff 192.75 KPa

Actual Dimension of footing

DL LL 2
A FTG AFTG 14.008 m AFTG B L
q eff

A FTG
L L 4.669 m L 4.70 m
B

Determination of the Actual Footing Depth

Actual Soil Pressure at the Base of Footing

1.4 DL 1.7 LL
q ult qult 293.617 KPa
B L
Nominal Shear Capacity (Wide Beam Shear along Transverse Direction)

d t Cc 1.5 b d 583 mm bw B bw 3 m
1
fc bw 1000 d
6
Vc Vc 1542.473 KN s 0.85
1000

Ultimate Shear Capacity


Vcult s Vc Vcult 1311.102
KN

Actual Shear acting at the Critical Section

Cx
L
Vcact q ult 1000

d
B
2 1000 Vcact 1292.209 KN

Vcult Vcact

Nominal Shear Capacity (Wide Beam Shear along Longitudinal Direction)

d t Cc 1.5 b d 583 mm bw L bw 4.7 m


1
fc bw 1000 d
6
Vc Vc 2416.541 KN s 0.85
1000

Ultimate Shear Capacity


Vcult s Vc Vcult 2054.06
KN

Actual Shear acting at the Critical Section

Cy
B
Vcact q ult 1000

d
L
2 1000 Vcact 851.46 KN

Vcult Vcact

Nominal Shear Capacity (Punching Shear)

Cx d Cy d 1
fc b o 1000 d
b o 2 bo 4.732 m
1000 1000 Vp
3
Vp 4865.988 KN
1000
Ultimate Shear Capacity

Vpult s Vp Vpult 4136.09 KN

Actual Shear acting at the Critical Section

Cx d Cy d
Vpact q ult B L Vpact 3729.086 KN
1000 1000

Vpult Vpact

Adopt :
t 700 mm L 4.7 m B3 m d 583 mm qult 293.617 KPa
Design of Steel requirements :

A. Along Longitudinal Direction Cx 600 mm Cy 600 mm b 0.90 dL d b

Cx Cx
L L
M ult q ult B
1000 1000
Mult 1850.888 KN m
2 4
2
Mult 1000
Ru
2 Ru 1.836 Mpa 0.85
b B 1000 d L

fc 2 Ru
1 1 0.0069569
fy 0.85 fc

1.4 0.85 fc 600
min min 0.0050909 bal max 0.75 bal max 0.0378327
fy
fy 600 fy

use 0.0069569
use dL d b

2
As B 1000 dL As 12752.037 mm

2 2
A 28 b A28 615.752 mm
4
As
Nbars Nbars 20.71 N 21 pcs
A 28

A. Along Transverse Direction


Cx 600 mm Cy 600 mm b 0.90 dT d

Cy Cy
B B
M ult q ult L 1000
1000
Mult 993.6 KN m
2 4
2
Mult 1000
Ru
2 Ru 0.691 Mpa 0.85
b L 1000 d T

fc 2 Ru
1 1 0.0025506
fy 0.85 fc

1.4 0.85 fc 600
min min 0.0050909 bal max 0.75 bal max 0.0378327
fy
fy 600 fy

use min 0.0050909

2
As L 1000 dT As 13949.6 mm

2 2
A 28 b A28 615.752 mm
4
As
Nbars
A 28 Nbars 22.655 N 23 pcs

Check Development Length :


Required Development Length
2 0.02 A b fy
Ab A28 Ab 615.752 mm ldb1 ldb1 640.014 mm
fc
or
ldb1 ldb2

ldb2 0.06 b fy ldb2 462 mm


use ldb ldb1

ldb 640.014 mm
Furnished Development Length

A - Along Longitudinal Direction

Cx
L
Ldbl 1000 Cc
1000
Ldbl 1975 mm Ldbl ldb
2
B - Along Transverse Direction

Cy
B
Ldbt 1000 Cc
1000
Ldbt 1125 mm Ldbt ldb
2

Check Dowel Requirements :

Actual Bearing Stength Pu 1.4 DL 1.7 LL Pu 4140 KN

Bearing Stress Reduction Factor A2


2
K
A1

2
A1 Cx Cy A1 360000 mm


A2 Cx 4d Cy 4d A2 8596624
mm
2

A2
K K 4.887 K 2 K 2
A1

br 0.70
Allowable Bearing Stress

br 0.85 fc A 1
PBS K PBS 11995.2 KN
1000
PBS Pu

Minimum Dowel Requirement by Code :

2
Adowel 0.005 Cx Cy Adowel 1800 mm

2 Adowel
Ab 615.752 mm Ndowel Ndowel 2.923
Ab

Note : Extend three (3) column bars into the footing

Detailing Requirements:
L 4.7 m B3 m t 700 mm d 583 mm

Main bars use 21-28 mm diameter main bars along Longitudinal Direction and
23-28 mm diameter main bars along Transverse Direction
Distribution of Bars along Transverse Direction

L

B 1.567 N 23

Along center band:

Ncenterband 2 2 N
Ncenterband Ncenterband 17.922 say 18 pcs
N 1 1

Nouterband N Ncenterband Nouterband 5.078 say 6 pcs