2015 - CW Catalogue Cables and Wires A4 En-2

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1156

J Edition 27

CABLES, WIRES & ACCESSORIES

helukabel.co.uk
I1T5ODUCTIO1

With our new main catalog "Cables & Wires" you are holding in
your hands a version that has been revised in visual presentation
as well as in content. Our objective was and is to guide you more
quickly to your desired product. The tabular overviews that
precede each product chapter should help in this regard.
Futhermore, we have developed additional selection tables that
facilitate navigation between the chapters.
We are proud of the fact that in the areas of industrial and
infrastructure cables we are uniformly well-positioned with high
in-stock availability. True to our motto, "All from One Source", in
addition to the "Data, network & BUS technology" section, we also
included a selection of accessory products in the main catalog for
the rst time. 1ew products created since our last catalog are
placed in their respective chapters.
In cases where more than 33,000 standard products are not
enough to nd the right cable product for a unique application
our engineers are at your side to develop both a technically and
economically superior solution. Your advancement is our driving
force!

Helmut Luksch
&JKGH(ZGEWVKXG2HEGT+(/8.$%(/*OD+

1
HELUKABEL AT A *LA1CE

FAMILY FOCUSED
Family enterprise since 1978

QUALITY-MINDED AND SUCCESSFUL

ECO-FRIENDLY 430 million Euro turnover

ISO 9001 & 14001 1000 employees

Energy supplied by the rm


s own
solar and bio-gas plant

GLOBAL PRODUCTION
41 locations in 24 countries 6 manufacturing and
assembly locations
worldwide

LOGISTICS PRODUCTS
33,000 products in stock, from Cables, wires and cable accessories
the cable gland to the 2.40 m - single-source supplier for
cable drum industry and infrastructure
24 h delivery service
State-of-the-art logistics
facility

2
TABLE OF CO1TE1TS

INTRODUCTION .................................................................................................................................................................. 1
5esearch & development ....................................................................................................................................................... 4
Production ............................................................................................................................................................................ 6
Logistics ................................................................................................................................................................................ 8
Success through quality and innovation ................................................................................................................................. 10
Our branded products ........................................................................................................................................................... 12
Always close to you - 41 locations in 24 countries ................................................................................................................. 14
5obotec Systems ................................................................................................................................................................... 16
Kabelmat Wickeltechnik ........................................................................................................................................................ 18
Chapter overview .................................................................................................................................................................. 20

INDUSTRIAL CABLES & WIRES ............................................................................................................................................ 24

INFRASTRUCTURE CABLES & WIRES .................................................................................................................................. 512

DATA, NETWORK & BUS TECHNOLOGY ............................................................................................................................. 604

MEDIA TECHNOLOGY ......................................................................................................................................................... 764

RENEWABLE ENERGY & TRANSPORTATION ...................................................................................................................... 794

PRE-ASSEMBLED CABLES ................................................................................................................................................... 840

SPIRAL CABLES ................................................................................................................................................................... 906

SHIPWIRING & MARINE CABLES ........................................................................................................................................ 918

CABLE ACCESSORIES .......................................................................................................................................................... 940

TECHNICAL INFORMATION ................................................................................................................................................ 1016


Selection tables ..................................................................................................................................................................... 1020
Assembly instructions ........................................................................................................................................................... 1034
Questionnaires...................................................................................................................................................................... 1038
Technical explanations .......................................................................................................................................................... 1044
Glossary of cables and wires .................................................................................................................................................. 1151
Part number index................................................................................................................................................................. 1158

3
4
5ESEA5CH & DE9ELOP0E1T

We develop optimal, tailored cable solutions for our customers.

5esearch and development are the foun- high-quality product relative to properties
dation of our work and are an important and workmanship.
engine for growth. In interdisciplinary With continuous optimization of our
teams we continuously push the manufacturing processes and systems
boundaries to enhance our products and we take into consideration both efcient
develop solutions to meet the latest and economical production, and the
technological demands. 0oreover, we complex requirements of various
value our customer interactions and applications (such as cables for industrial
partnerships with regional colleges and robots or for applications under
research institutes to stay on top of cleanroom conditions) into account.
emerging technologies.
A crucial stage in the development
The materials that we use are an process of our products is the work done
important starting point of our work. In at our Test Center. For example, cables
this regard, we place as much emphasis suitable for drag chain implementation,
on searching for and utilizing new can be tested using equipment that
Torsion test apparatus materials, as we do on manufacturing accelerates cables up to 10 g.
our plastic mixtures (granulates) our- Temperature ranges from -50 to +250
selves, and inuencing the improvement are simulated in a special climate-
of technical characteristics, such as controlled environment so that drag
Our test facilities:
oil-resistance, temperature range or chain cables can be tested for series
chemical compatibility. 0oreover, we are production readiness in applications such
Test systems for bending and
capable of pulling a majority of the as refrigerated warehouses or steel mills.
torsion requirements
copper ourselves, thus ensuring a uniform,

Drag chain test systems with


movement distances of 1 m,
3 m, 5 m, 6 m, 18 m, and 40 m

Fire testing systems

Abrasion testing systems

Torsion test tower for


wind turbine cables

Aging ovens in accordance with


UL, 9DE, CSA, HA5, T9 & CCC

Drag chain test system

5
|6
P5ODUCTIO1
We specialize in the production of high-quality cables and wires.

Using the latest production methods, our two German plants Since 2014, in a 7,000 m facility in the Chinese city of Taicang
manufacture approximately one million kilometers of conductors (approx. 50 km northwest of Shanghai) HELUKABEL has been
each year ( 77 times around the world). 0ore than 300 producing cable and wires, primarily for the Asian market. As is
qualied employees are specialized in the production of with our German plants, the focus is on high-quality, exible and
high-quality standard and custom cables. Through the use of the highly-exible cables and wires that are manufactured in
latest materials and collaboration with international test accordance with Chinese and international standards. The use of
institutes, we drive innovation in the areas of automation, data exible manufacturing cells enable short delivery times.
technology, building system technology, and renewable energy.

Braiding machine Stranding machine

Our production in numbers:

40,000 m production area


23 extruder systems
19 stranding machines
50 braiding machines
Cables & wires from 0.05 to 1,000 mm (30 AWG to 2,000 kcmil)
0anufacturing in accordance with: 9DE, EAC (GOST-5), UL, CSA, HA5, CCC,
Germanischer Lloyd, T9 or customer specication

7
8
LOGISTICS
5edening logistics in the cable industry.

INDUSTRIAL CABLE At its corporate headquarters in the Swabian town of Hemmingen/


Our logistics center - Hemmingen/Stuttgart Stuttgart, HELUKABEL operates Europe
s largest distribution
40,500 Euro-pallet racks center for cables and wires. Here a majority of the more than
16 aisles with 16 storage and retrieval devices 33,000 products are located in a storage area of 160,000 m.
35,900 bin locations in the automatic small parts Through the use of state-of-the-art conveyor and control
warehouse with a capacity of 1,000 bins per hour technology, more than 1,000 orders can be picked and
670 storage spaces in the heavy load warehouse dispatched daily to destinations around the world.
with max. reels of 4,000 kg and 2.20 m diameter
2 km conveyor line for pallets 1euenhagen/Berlin is the central warehouse location for under-
Conveyer connects direct to the cable-cutting machines ground, medium-voltage, and other infrastructure cables.
0anual processes reduced to merely packing Storage capacities of more than 5,000 m (indoor) and 50,000 m
(outdoor) enable fast delivery of cable, congured from 1 30 k9,
INFRASTRUCTURE CABLES to construction sites and major projects. The patented heavy-
Our logistics center - Neuenhagen/Berlin load cable-cutting machines with a load capacity of more than
11,000 cable reels in stock 10 tons are the largest of their kind in Germany.
Automatic processing of reels up to 2.80 m and 10 t
10 rewinding machines The new logistics center at the Taicang (Shanghai, China)
Cut to length with state-of-the-art 1,200 mm production facility serves as a product distribution hub for the
cutting tools Asian market, and offers incredible advantages, particularly for
24-hr delivery is possible servicing time- and volume-critical customer projects.

Heavy-load, cable-cutting facility Small parts warehouse

9
10
SUCCESS THROUGH QUALITY AND INNOVATION
Quality and environmental principles

HELUKABEL GmbH is an independent enterprise that requirements, as well as corporate environmental protection.
manufactures and sells cables, wires, and accessories. Our standard is customer satisfaction and trust. Indicators of
HELUKABEL
has a high commitment to quality and the this are the economic success of the enterprise and long-stand-
environment. For this reason the executive board has ing customer relationships.
introduced an integrated management system for quality Fulllment of our quality and environmental principles is an
and the environment based on DIN EN ISO 9001:2008 and obligation and ongoing task of the executive board and each
DIN EN ISO 14001:2009 standards. individual employee. Our high standards are expressed in the
HELUKABEL GmbH's quality and environmental policy is following criteria:
oriented to meet market needs and fulll customer

Environment Employees
Environmental protection in the enterprise is a Qualied employees who work
principle of our work and is not only oriented cooperatively in teams and combine a high
to comply with legal requirements, but rather level of individual responsibility and autonomy
to avoid or minimize pollution and its effects with a marked awareness of quality and the
on the environment. environment ensure the success of the
management system at HELUKABEL GmbH.

Quality Suppliers
Reliable products that meet the Develop partnerships with suppliers
specications to satisfy customer who will work together with us to
requirements. satisfy our quality and environmental
standards.

Objectives Conduct
Products complying with require- Cost awareness and environmental
ments and timely order processing, awareness are maintained by
whereby environmental impact is every employee to satisfy customer
avoided or kept to a minimum. requirements, while maintaining the
ability to react effectively to changing
circumstances.

Approach Continuous improvement


Upright action to maintain credibility in Continuously develop and implement
collaboration with our customers. enhancements of the products, processes,
environmental protection procedures, and
occupational health and safety.

The integrated quality and environmental management system supports the success factors of HELUKABEL GmbH and documents
how we work; this is described in the management manual, which is binding for all employees.

11
04 | 12
OUR BRANDED PRODUCTS
Cables & wires
BIOFLEX-500 bio-oil resistant cables
CLEANFLEX cleanroom data and control cables
DATAFLA00 data and computer cables, halogen free
DATAPUR-C data and computer cables
GALVANICABLE high-voltage cathode cable
HELUFLON heat-resistant cables
HELUTHER0 heat-resistant cables
HELUTRAIN train cables
HELUTRUCK vehicle cables/truck cables
HELUWIND wind power cables
KO0POFLEX microbe-resistant cables
KO0POSPEED bio-oil resistant drag chain cables
LIFT-TRAGO elevator control cables
0EGAFLEX exible control cables, halogen free, UL/CSA
0ULTIFLEX 512 PUR drag chain cables
0ULTISPEED drag chain cables
NANOFLEX PUR special control and data cables
ROBOFLEX robot cables
SENSORFLEX sensor cables
SHIPFLEX drag chain cables
SOLARFLEX photovoltaic cables
SUPER-PAAR-TRONIC-C-PUR drag chain cables, halogen free
SUPERTRONIC drag chain cables
THER0FLEX heat-resistant cables
TOPFLEX servo, feedback and motor cables
TOPSERV servo, feedback and motor cables
TRAYCONTROL exposed run cable
TRO00PUR easy-to-wind cables
UNIPUR PUR, exible control cables

Cable accessories
HELUCHAIN drag chain product line
HELUTEC industrial connector series
HELUTOP cable gland product line

Data, network & bus technology


HELUCO0 ber optic cables
ber optic connection technology
HELUKAT copper data cable
copper connection technology

0edia technology
HELUEVENT high-powered cable for TV studios
HELULIGHT cables for lighting control systems
HELUSOUND audio cable

13
ALWAYS CLOSE TO YOU - 41 LOCATIONS IN 24 COUNTRIES

HELUKABEL GmbH - Germany

Headquarters
Dieselstrasse 8-12
71282 Hemmingen / Stuttgart
Telephone: +49 7150 9209-0
Fax +49 7150 81786
[email protected]

6NGUQHEG YTGJQWUGm%GTNKP 6NGUQHEG YTGJQWUGm3NGK 6NGUQHEGm1QTVJ


=um 0hleniess 1 Eichelbergstrasse 7 Bahnhofstrasse 9
15366 Neuenhagen / Berlin 09212 Limbach-Oberfrohna 25524 Itzehoe
Telephone +49 3342 2397-0 Telephone +49 3722 6086-0 Telephone +49 4821 40394-0
Fax +49 3342 80033 Fax +49 3722 6086-420 Fax +49 4821 40394-29
[email protected] [email protected] [email protected]

6NGUQHEGm5JGKPm5WJT Development & production


Am Handwerkshof 2-4 Neuseser Weg 11
47269 Duisburg 91575 Windsbach
Telephone +49 203 73995-0 Telephone +49 9871 6793-0
Fax +49 203 73995-210 Fax +49 9871 1055
[email protected] [email protected]

Robotec Systems GmbH - Germany


+GFQHEG   %TPEJQHEGm6QWVJ 
Carl-Friedrich-Gau-Strasse 7 Willi-Bleicher-Strasse 4-6
47475 Kamp-Lintfort 71282 Hemmingen
Telephone: +49 (0)2842 92148-0 Telephone: +49 (0)7150 9209-308
Fax: +49 (0)2842 92148-10 Fax: +49 (0)7150 9209-164
www.robotec-systems.de www.robotec-systems.de
[email protected] [email protected]

Kabelmat Wickeltechnik GmbH - Germany


Steinbuckelweg 25
72293 Glatten
Tel. +49 7443 9670-0
Fax +49 7443 9670-39
[email protected]

14
HELUKABEL international locations

HELUKABEL Austria HELUKABEL Malaysia HELUKABEL Switzerland


Tel +43 7224 90555 0 Tel.: +603 7885 8724 Tel.: +41 56 4181515
Email: [email protected] Email: [email protected] Email: [email protected]

HELUKABEL Belgium HELUKABEL Middle East HELUKABEL Thailand


Tel.: +32 24 81 00 20 Tel.: +971 48 87 95 94 Tel.: +66 2927 3570 3
Email: [email protected] Email: [email protected] Email: [email protected]

HELUKABEL Canada HELUKABEL Netherlands HELUKABEL Turkey


Tel.: +1 289 444 5040 Tel.: +31 495 499 049 Tel.: +90 212 502 41 95
Email: [email protected] Email: [email protected] Email: [email protected]

HELUKABEL China HELUKABEL Poland HELUKABEL UK


Tel.: +86 21 58693999 Tel.: +48 46 85 80 10 0 Tel.: +44 151 345 0808
Email: [email protected] Email: [email protected] Email: [email protected]

HELUKABEL Czech Republic HELUKABEL Russia HELUKABEL USA


Tel.: +42 0312 672 620 Tel.: +7 812 449 10 60 Tel.: +1 847 930 5118
Email: [email protected] Email: [email protected] Email: [email protected]

HELUKABEL France HELUKABEL Singapore


Tel.: +33 389 627562 Tel.: +65 65 54 6170
Email: [email protected] Email: [email protected]

HELUKABEL India HELUKABEL South Africa


Tel.: +91 22 25 18 58 41 Tel.: +27 11 462 8752
Email: [email protected] Email: [email protected]

HELUKABEL Indonesia HELUKABEL South Korea


Tel.: +62 213 848872 Tel.: +82 51 9728646
Email: [email protected] Email: [email protected]

HELUKABEL Italy HELUKABEL Sweden


Tel.: +39 039 6081503 Tel.: +46 8 55 77 4280
Email: [email protected] Email: [email protected]

15
ROBOTEC SYSTE0S - UN0ATCHED ROBOTIC CO0PETENCE

Since its founding in 1998, Robotec and ready to install. From the development
Systems GmbH, headquartered in Kamp- of various design concepts to prototyping,
Lintfort, Germany, has become one of the to nal installation and on-site service,
leading European companies for robot Robotec is a single source for all robotic
hose packages and associated fastening services.
systems as well as for custom robot Through the use of rst-class components,
Concept
cables, cable assemblies, power screw- as well as superstructures and material
driver technology, controllers for meas- compositions tailored for the respective
urement instrumentation and media application, the highest level of reliability
systems such as air hoses and water hoses. and productivity is achieved.
The company has been a 100% Robotec's products are used in applications,
subsidiary of HELUKABEL GmbH since such as spot, laser and inert gas welding,
July 2012. robot handling, and tool changing
Robotec Systems develops tailored energy- systems. Development

supply systems that are pre-assembled

Prototyping
Our components:

Fastening elements & accessories Cable protection hoses


Pivot bearings Attachment parts
Spring clamps Primary cables
Protector/impact protection Control cables
Trumpet & accessories BUS system cables
Installation/optimization
Precision pipes Pre-assembled special cables
Self-fastening hoses & accessories

Documentation
+GFQHEG %TPEJQHEGm6QWVJ
Robotec Systems GmbH Robotec Systems GmbH
Carl-Friedrich-Gau-Strasse 7 Willi-Bleicher-Strasse 4-6
47475 Kamp-Lintfort, Germany 71282 Hemmingen
Telephone: +49 (0)2842 92148-0 Telephone: +49 (0)7150 9209-308
Fax: +49 (0)2842 92148-10 Fax: +49 (0)7150 9209-164
www.robotec-systems.de www.robotec-systems.de
[email protected] [email protected]
Repair/maintenance

17
18
KABEL0AT WICKELTECHNIK G0BH
Kabelmat Wickeltechnik GmbH's history goes back to the 1960s
and since then the company has been among the market leaders for
winding systems in the cable and wire industry.
Customers include manufacturers, retailers, cable and wire
processors, as well as cable assemblers, electricians, machine
manufacturing companies, and many more.
The product range includes virtually all devices and machines for
storing, winding and cutting cables, wires, rope, tubes, hoses, and
proles.
Winding from and onto drums, as well as from drums to rings are
among the tasks that are efciently executed worldwide with
Kabelmat products.
We would be pleased to show you our products in our showroom.
You are cordially invited to visit us at our facility.

0ESSBOI 40

We offer: Our services: Kabelmat Wickeltechnik GmbH


0anual winding technology Project planning & engineering Steinbuckelweg 25
Automatic winding technology 0anufacturing & nal 72293 Glatten
Tel. + 49 7443 9670-0
0easuring technology assembly
Fax + 49 7443 9670-39
Storage technology Service & maintenance [email protected]

PORTROL 2600 - 3000

19
CHAPTER OVERVIEW
INDUSTRIAL CABLES & WIRES

Flexible control cables


26 - 121 Robot cables

with international approvals 260 - 267


A 355 - 401 H

Data and computer cables


122 - 157 Water-resistant cables

with international approvals 268 - 273


B 402 - 421 I

Drag chain cables


158 - 193 Flat & ribbon cables

with international approvals 274 - 283


C 422 - 451 J

Motor, servo & feedback cables Single Conductors


194 - 217 284 - 323

with international approvals with international approvals


D 452 - 474 K 484 - 506

Heat-resistant cables
218 - 237 Compensating cables

with international approvals 324 - 335


E 475 - 478 L

Allweather & rubber cables


238 - 251 Coaxial cables

with international approvals 336 - 347


F 479 - 481 M

Trailing cables
252 - 259 Cables according to
International Approvals
with international approvals
348 - 511
G 483 N

20
INFRASTRUCTURE CABLES & WIRES MEDIA TECHNOLOGY

Installation cables Media technology

512 - 521 764 - 793


O S

7GNGRJQPG TGYTPKPIEDNGU

522 - 533
P
RENEWABLE ENERGY & TRANSPORTATION

3QYGTUGEWTKV[  Cables for photovoltaic


medium voltage cables installations

534 - 603 794 - 801


Q T

&DNGUHQTYKPFVWTDKPGU

802 - 821
T
DATA, NETWORK & BUS TECHNOLOGY

Cables for
Fiber optic cables
aircraft supply
604 - 651
822 - 825
R T

Copper data cable Cables for commercial vehicles

652 - 683 826 - 831


R T

BUS cables &DNGUHQTVTKP VTHE

684 - 763 832 - 839


R T

21
CHAPTER OVERVIEW
PRE-ASSEMBLED CABLES CABLE ACCESSORIES

Servo motor, feedback &


Cable glands
fan cables
942 - 967
840 - 877
U X

ROBOFLEX recycle Cable protection tube systems

878 - 897 968 - 975


U X

Connecting cables &


Shrink tubes
extensions
976 - 979
898 - 905
U X

Cable ties

980 - 985
X
SPIRAL CABLES

Spiral cables Core end sleeves & cable lugs

906 - 917 986 - 999


V X

Tools

1002 - 1017
X

SHIPWIRING & MARINE CABLES

Shipwiring & marine cables

918 - 939
W

22
TECHNICAL INFORMATION

Technical information

1018 - 1172
Y

23
Table of contents

04 | 24
INDUSTRIAL CABLES & WIRES

Flexible control cables 26

Data and computer cables 122

Drag chain cables 158

Motor, servo & feedback cables 194

Heat-resistant cables 218

Allweather & rubber cables 238

Trailing cables 252

Robot cables 260

Water resistant cables 268

Flat & ribbon cables 274

Single conductors 284

Compensating cables 324

Coaxial cables 336

Cables according to International approvals 348

25
FLEXIBLE CONTROL CABLES A

3
in

E
VD eld 29
ng

x
xe
ex

VD
ed
U

R/ shi E 0
xi
- fi
- fl

./
0 /

le

ed
i

no
H A ed / VD
-f

-f
U
C)

C)

ge

us

us

CS REG
e n es /
(

e
lta

di

di

se
re

re

t
fre

ut tan

r
n
ra

ra

co
tu

tu

u
vo

E
ai
n-

or
sis
ra

ra

A
d
ch
al

ge
in

in
pe

pe

re
do
re
in

ge
nd

nd

ag
lo

lo

re
V-
m

L/
om

Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
N
PVC control cables

JZ-500 -15 to +80 -40 to +80 300/500 7.5x 4x X 30

JZ-500 black -15 to +80 -40 to +80 300/500 7.5x 4x X X 32

JZ-500 orange -15 to +80 -40 to +80 300/500 7.5x 4x X 33

JZ-500 COLD -30 to +80 -40 to +80 300/500 7.5x 4x X 34

H05VV5-F (NYSLY-JZ) -5 to +70 -40 to +70 300/500 7.5x 4x X 35

(H)05VV5-F ((N) YSLY-JZ) -5 to +70 -40 to +70 300/500 7.5x 4x X 37

JZ-750 -15 to +80 -40 to +80 450/750 7.5x 4x 38

JZ-600 -15 to +80 -40 to +80 0.6/1 kV 7.5x 4x X X 40

JB-500 -15 to +80 -40 to +80 300/500 7.5x 4x X X 42

JB-750 -15 to +80 -40 to +80 450/750 7.5x 4x X 43

JB-750 yellow -15 to +80 -40 to +80 450/750 7.5x 4x X 44

H03VV-F -5 to +70 -40 to +70 300/300 7.5x X X 45

H05VV-F -5 to +70 -40 to +70 300/500 7.5x X X 46

H05VV-F -5 to +70 -40 to +70 300/500 7.5x X X 47

F-CY-OZ (LiY-CY) -10 to +80 -40 to +80 300/500 10x 5x X X 48

F-CY-JZ -10 to +80 -40 to +80 300/500 10x 5x X X 50

JZ-500 C black -10 to +80 -40 to +80 300/500 10x 5x X X X 52

Y-CY-JZ -15 to +80 -40 to +80 300/500 10x 5x X X 53

SY-JZ -15 to +80 -40 to +80 300/500 20x 6x X X 55

H05VVC4V5-K (NYSLYCY-JZ) -5 to +70 -40 to +70 300/500 10x 5x X X 57

(H)05VVC4V5-K ((N)YSLYCY-JZ -5 to +70 -40 to +70 300/500 10x 5x X X 59

JZ-600-Y-CY -15 to +80 -40 to +80 0.6/1 kV 10x 5x X X X 60

Y-CY-JB -15 to +80 -40 to +80 300/500 10x 5x X X X 62

SY-JB -15 to +80 -40 to +80 300/500 20x 6x X X X 64

PUR control cables

JZ-500 PUR -15 to +80 -40 to +80 300/500 7.5x 4x X X 67

PUR-JZ -20 to +80 -40 to +80 300/500 7.5x 4x X X 68

PUR-ORANGE -15 to +80 -40 to +80 300/500 7.5x 4x X X X 70

PUR-YELLOW -15 to +80 -40 to +80 300/500 7.5x 4x X X X 71

H05 BQ-F / H07 BQ-F (NGMH11Y) -40 to +80 -50 to +90 300/500 5x 3x X X X X 72

UNIPUR -40 to +90 300/500 10x 5x X X X X X 73

PUR-750 -40 to +80 300/500 10x 5x X X X X 75

JZ 500-FC-PUR -10 to +80 -40 to +80 300/500 10x 5x X X X 76

F-C-PUR-JZ -20 to +80 -40 to +80 300/500 10x 5x X X X 78

Y-C-PUR-JZ -20 to +80 -40 to +80 300/500 10x 5x X X X 80

UNIPUR-CP -40 to +90 300/500 12.5x 7.5x X X X X X 82

PUR-C-PUR -40 to +80 300/500 10x 5x X X X X X 84

27
FLEXIBLE CONTROL CABLES

3
in

E
VD eld 29
ng

x
ge
xe
ex

VD
vo U

R/ shi E 0
xi
lta
ak 0 /
- fi
- fl

./
fle

ix
pe U

ed

no
H A ed / VD
-f
C)

C)

g ge

s-

us

CS REG
e n es /
(

tin lta

e
di

di

se
re

re

t
re

n
ra vo

r
n
ra

ra

co
tu

tu

u
f

E
ai
n-

t
pe l

or
sis
ra

ra

g
O ina

A
d
ch
ge
in

in
pe

pe

re
do
re

ge
om

nd

nd

ag
lo

lo

re
V-
m

L/
ut
Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
Halogen-free control cables

JZ-500 HMH -15 to +70 -40 to +70 300/500 12.5x 4x X 86

MEGAFLEX 500
-30 to +80 -40 to +80 300/500 10x 4x X X X X 88

H07 ZZ-F -5 to +70 -20 to +70 450/750 10x 4x X X 90

JZ-600 HMH -15 to +70 -40 to +70 0.6/1 kV 15x 7.5x X X 91

JB-750 HMH -15 to +70 -40 to +70 450/750 12.5x 4x X X 93

(H)03 Z1Z1-F -5 to +70 -40 to +70 300/500 7.5x X X 94

(H)05 Z1Z1-F -5 to +70 -40 to +70 300/500 7.5x X X 95

JZ-500 HMH-C -15 to +70 -40 to +70 200/500 12.5x 4x X X 96

MEGAFLEX 500-C
-30 to +80 -40 to +80 300/500 10x 4x X X X X X 98

JZ-600 HMH-C -15 to +70 -40 to +70 0.6/1 kV 15x 7.5x X X X 100

JB-750 HMH-C -15 to +70 -40 to +70 450/750 12.5x 4x X X X 102

Inherently safe PVC control cables

OZ-BL -15 to +80 -40 to +80 300/500 7.5x 4x X 105

OZ-BL-CY -10 to +80 -40 to +80 300/500 10x 5x X X 106

OB-BL-PAAR-CY -10 to +80 -30 to +80 900 10x 5x X X 107

Bio-oil & microbe-resistant cables

BIOFLEX-500-JZ -20 to +80 -40 to +80 300/500 15x 4x X 109

BIOFLEX-500 -JZ-C
-20 to +80 -40 to +80 300/500 20x 6x X X 110

KOMPOFLEX JZ-500 -30 to +90 -40 to +100 300/500 7.5x 4x X X X 112

KOMPOFLEX JZ-500-C

-30 to +90 -40 to +100 300/500 7.5x 4x X X X X 113

Hygienic cable

NANOFLEX HC*500 -5 to +80 -40 to +80 300/500 7.5x 4x X X 116

NANOFLEX HC*500-C -5 to +80 -40 to +80 300/500 10x 5x X X X 117

NANOFLEX HC*TRONIC

-5 to +80 -40 to +80 350 7.5x 4x X X X X 118

NANOFLEX HC*TRONIC-C -5 to +80 -40 to +80 350 10x 5x X X X X 120

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

28
PVC CONTROL CABLES
Flexible Control Cables / PVC Control Cables

JZ-500 flexible, number coded, meter marking

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC conditional drag chain compatible
flexing -15C to +80C compound type Z 7225 conditional suitability for torsion
fixed installation -40C to +80C Core identification to DIN VDE 0293 The materials used in manufacture are
Nominal voltage U0/U 300/500 V black cores with continuous white cadmium-free and contain no silicone
Test voltage 4000 V numbering (also available in other and free from substances harmful to
Breakdown voltage min. 8000 V colours on request) the wetting properties of lacquers
Insulation resistance GN-YE conductor, 3 cores and above Tests
min. 20 MOhm x km in the outer layer PVC self-extinguishing and flame retardant
Minimum bending radius Cores stranded in layers with acc. to DIN VDE 0482-332-1-2,
flexing 7,5x cable optimal lay-lenght DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation 4x cable Outer sheath of special PVC DIN VDE 0472 part 804 test method B)
Radiation resistance compound type TM2 to
up to 80x106 cJ/kg (up to 80 Mrad) DIN VDE 0207-363-4-1/DIN EN 50363-4-1 Note
Sheath colour grey (RAL 7001) G = with green-yellow conductor
with meter marking x = without green-yellow conductor (OZ)
We supply any "desired length" of stranded
cores without outer sheath, core insulation
colour acc. RAL 9005 with number
combination acc. customers requirement.
Please note the cleanroom qualification when
ordering.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
F-CY-JZ, confer page 50
F-CY-OZ (LiY-CY), confer page 48
Y-CY-JB, confer page 62
Y-CY-JZ, confer page 53

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, as measuring and control cables in tool machines, conveyor belts, production lines in machinery production,
in air-conditioning and in steel production.
Selected PVC-compounds guarantee a good flexibility as well as an economic and fast installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10001 2 x 0,5 4,8 9,6 40,0 20 10025 50 G 0,5 17,5 240,0 513,0 20
10002 3 G 0,5 5,1 14,4 46,0 20 10169 52 G 0,5 17,5 252,0 534,0 20
10003 3 x 0,5 5,1 14,4 46,0 20 10026 61 G 0,5 18,5 293,0 625,0 20
10004 4 G 0,5 5,5 19,0 56,0 20 10027 65 G 0,5 19,4 312,0 682,0 20
10005 4 x 0,5 5,5 19,0 56,0 20 10028 80 G 0,5 21,4 384,0 780,0 20
10006 5 G 0,5 6,2 24,0 65,0 20 10029 100 G 0,5 24,0 480,0 980,0 20
10007 5 x 0,5 6,2 24,0 65,0 20 10030 2 x 0,75 5,3 14,4 46,0 19
10008 6 G 0,5 6,7 29,0 75,0 20 10031 3 G 0,75 5,6 21,6 54,0 19
10009 7 G 0,5 6,7 33,6 80,0 20 10032 3 x 0,75 5,6 21,6 54,0 19
10010 7 x 0,5 6,7 33,6 80,0 20 10033 4 G 0,75 6,3 28,8 66,0 19
10011 8 G 0,5 7,4 38,0 97,0 20 10034 4 x 0,75 6,3 29,0 66,0 19
10172 8 x 0,5 7,4 38,0 97,0 20 10035 5 G 0,75 6,9 36,0 80,0 19
10012 10 G 0,5 8,3 48,0 116,0 20 10036 5 x 0,75 6,9 36,0 80,0 19
10013 12 G 0,5 8,7 58,0 135,0 20 10037 6 G 0,75 7,5 43,0 99,0 19
10014 12 x 0,5 8,7 58,0 135,0 20 10177 6 x 0,75 7,5 43,0 99,0 19
10015 14 G 0,5 9,5 67,0 150,0 20 10038 7 G 0,75 7,5 50,0 110,0 19
10183 16 G 0,5 10,0 76,0 175,0 20 10039 7 x 0,75 7,5 50,0 110,0 19
10016 18 G 0,5 10,7 86,0 196,0 20 10040 8 G 0,75 8,3 58,0 130,0 19
10017 20 G 0,5 11,3 96,0 215,0 20 10173 8 x 0,75 8,3 58,0 130,0 19
10018 21 G 0,5 11,3 101,0 240,0 20 10041 9 G 0,75 8,9 65,0 153,0 19
10019 25 G 0,5 12,6 120,0 270,0 20 10042 10 G 0,75 9,2 72,0 162,0 19
10020 30 G 0,5 13,5 144,0 310,0 20 10043 12 G 0,75 9,8 86,0 179,0 19
10021 32 G 0,5 14,0 154,0 323,0 20 10044 12 x 0,75 9,8 86,0 179,0 19
10022 34 G 0,5 14,3 163,0 362,0 20 10045 14 G 0,75 10,6 101,0 214,0 19
10023 40 G 0,5 15,3 192,0 434,0 20 10046 15 G 0,75 11,4 108,0 218,0 19
10024 42 G 0,5 15,8 202,0 449,0 20 10047 18 G 0,75 12,2 130,0 257,0 19

Continuation

30
Flexible Control Cables / PVC Control Cables

JZ-500 flexible, number coded, meter marking


Part no. No.cores x
cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No. Part no. No.cores x
cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No.
A
10533 19 G 0,75 12,2 137,0 264,0 19 10107 18 G 1,5 14,6 259,0 440,0 16
10048 20 G 0,75 12,7 144,0 286,0 19 10185 19 G 1,5 14,6 279,0 445,0 16
10049 21 G 0,75 12,7 151,0 320,0 19 10108 20 G 1,5 15,6 288,0 490,0 16
10050 25 G 0,75 14,3 180,0 365,0 19 10109 21 G 1,5 15,6 302,0 555,0 16
10534 27 G 0,75 14,6 195,0 382,0 19 10110 25 G 1,5 17,4 360,0 620,0 16
10051 32 G 0,75 15,9 230,0 455,0 19 10535 27 G 1,5 17,5 389,0 670,0 16
10052 34 G 0,75 16,5 245,0 510,0 19 10111 32 G 1,5 19,5 461,0 790,0 16
10182 37 G 0,75 16,7 266,0 537,0 19 10112 34 G 1,5 20,0 490,0 830,0 16
10053 40 G 0,75 17,2 288,0 595,0 19 10536 37 G 1,5 20,2 533,0 892,0 16
10054 41 G 0,75 18,1 296,0 607,0 19 10113 41 G 1,5 21,8 591,0 996,0 16
10055 42 G 0,75 18,1 302,0 612,0 19 10114 42 G 1,5 21,8 605,0 1007,0 16
10056 50 G 0,75 19,8 360,0 735,0 19 10115 50 G 1,5 24,2 720,0 1250,0 16
10057 61 G 0,75 21,2 439,0 845,0 19 10116 56 G 1,5 24,9 806,0 1332,0 16
10178 65 G 0,75 21,8 468,0 895,0 19 10117 61 G 1,5 25,8 878,0 1440,0 16
10058 80 G 0,75 24,3 576,0 1070,0 19 10187 65 G 1,5 26,8 936,0 1602,0 16
10059 100 G 0,75 27,0 720,0 1322,0 19 10118 80 G 1,5 29,8 1152,0 1871,0 16
10060 2x1 5,6 19,2 60,0 18 10119 100 G 1,5 33,2 1440,0 2353,0 16
10061 3G1 5,9 29,0 72,0 18 10120 2 x 2,5 7,8 48,0 112,0 14
10062 3x1 5,9 29,0 72,0 18 10121 3 G 2,5 8,3 72,0 148,0 14
10063 4G1 6,6 38,4 86,0 18 10122 3 x 2,5 8,3 72,0 148,0 14
10064 4x1 6,6 38,4 86,0 18 10123 4 G 2,5 9,2 96,0 178,0 14
10065 5G1 7,3 48,0 104,0 18 10124 4 x 2,5 9,2 96,0 178,0 14
10066 5x1 7,3 48,0 104,0 18 10125 5 G 2,5 10,1 120,0 221,0 14
10067 6G1 8,1 58,0 125,0 18 10126 5 x 2,5 10,1 120,0 221,0 14
10068 7G1 8,1 67,0 141,0 18 10127 7 G 2,5 11,2 168,0 306,0 14
10069 7x1 8,1 67,0 141,0 18 10128 7 x 2,5 11,2 168,0 306,0 14
10070 8G1 8,8 77,0 175,0 18 10129 8 G 2,5 12,3 192,0 363,0 14
10071 9G1 9,7 86,0 200,0 18 10548 10 G 2,5 14,1 240,0 429,0 14
10180 10 G 1 9,8 96,0 217,0 18 10130 12 G 2,5 14,8 288,0 498,0 14
10170 10 x 1 9,8 96,0 217,0 18 10131 14 G 2,5 16,0 336,0 569,0 14
10072 12 G 1 10,4 115,0 230,0 18 10132 18 G 2,5 18,2 432,0 764,0 14
10073 12 x 1 10,4 115,0 230,0 18 10133 21 G 2,5 19,2 504,0 914,0 14
10074 14 G 1 11,4 134,0 271,0 18 10134 25 G 2,5 21,6 600,0 1044,0 14
10075 16 G 1 12,3 154,0 300,0 18 10135 34 G 2,5 24,8 816,0 1470,0 14
10076 18 G 1 12,9 173,0 343,0 18 10136 42 G 2,5 27,4 1008,0 1790,0 14
10174 18 x 1 12,9 173,0 343,0 18 10137 50 G 2,5 30,0 1200,0 2095,0 14
10197 19 G 1 12,9 182,0 355,0 18 10138 61 G 2,5 32,0 1464,0 2750,0 14
10077 20 G 1 13,8 192,0 375,0 18 10139 100 G 2,5 41,4 2400,0 4450,0 14
10184 20 x 1 13,8 192,0 375,0 18 10140 2x4 9,2 77,0 195,0 12
10179 21 G 1 13,8 205,0 420,0 18 10141 3G4 9,8 115,0 230,0 12
10175 24 G 1 15,1 230,0 440,0 18 10142 4G4 10,9 154,0 295,0 12
10078 25 G 1 15,4 240,0 485,0 18 10143 5G4 12,1 192,0 361,0 12
10176 25 x 1 15,4 240,0 485,0 18 10144 7G4 13,2 269,0 458,0 12
10196 26 G 1 15,5 252,0 500,0 18 10145 8G4 14,7 307,0 590,0 12
10198 27 G 1 15,6 259,0 534,0 18 10549 10 G 4 16,8 384,0 687,0 12
10168 30 x 1 16,4 308,0 550,0 18 10146 12 G 4 17,7 461,0 790,0 12
10079 34 G 1 17,7 326,0 650,0 18 10147 3G6 11,9 173,0 355,0 10
10080 36 G 1 17,9 346,0 668,0 18 10148 4G6 13,0 230,0 424,0 10
10199 37 G 1 17,9 355,0 701,0 18 10149 5G6 14,5 288,0 525,0 10
10081 40 G 1 18,5 384,0 755,0 18 10150 7G6 16,2 403,0 625,0 10
10167 40 x 1 18,5 384,0 755,0 18 10151 3 G 10 14,9 288,0 540,0 8
10082 41 G 1 19,5 394,0 770,0 18 10152 4 G 10 16,5 384,0 701,0 8
10083 42 G 1 19,5 403,0 810,0 18 10153 5 G 10 18,3 480,0 858,0 8
10084 50 G 1 21,3 480,0 936,0 18 10154 7 G 10 20,2 672,0 1106,0 8
10085 56 G 1 21,9 538,0 920,0 18 10190 3 G 16 18,3 461,0 827,0 6
10086 61 G 1 22,5 586,0 1100,0 18 10155 4 G 16 20,1 614,0 1035,0 6
10087 65 G 1 23,6 628,0 1180,0 18 10156 5 G 16 22,6 768,0 1259,0 6
10088 80 G 1 26,1 768,0 1294,0 18 10157 7 G 16 24,8 1075,0 1780,0 6
10089 100 G 1 28,8 960,0 1644,0 18 10191 3 G 25 22,3 720,0 1186,0 4
10090 2 x 1,5 6,4 29,0 70,0 16 10158 4 G 25 25,0 960,0 1582,0 4
10091 3 G 1,5 6,8 43,0 90,0 16 10159 5 G 25 27,7 1200,0 1999,0 4
10092 3 x 1,5 6,8 43,0 90,0 16 10160 7 G 25 30,6 1680,0 2825,0 4
10093 4 G 1,5 7,4 58,0 109,0 16 10192 3 G 35 25,9 1008,0 1585,0 2
10094 4 x 1,5 7,4 58,0 109,0 16 10161 4 G 35 28,7 1344,0 2105,0 2
10095 5 G 1,5 8,3 72,0 131,0 16 10162 5 G 35 31,9 1680,0 2633,0 2
10096 5 x 1,5 8,3 72,0 131,0 16 10193 3 G 50 30,8 1440,0 2550,0 1
10097 6 G 1,5 9,2 86,0 157,0 16 10163 4 G 50 34,1 1920,0 2940,0 1
10098 7 G 1,5 9,2 101,0 184,0 16 10188 5 G 50 38,1 2400,0 2936,0 1
10099 7 x 1,5 9,2 101,0 184,0 16 10194 3 G 70 36,4 2016,0 3180,0 2/0
10100 8 G 1,5 10,0 115,0 216,0 16 10164 4 G 70 40,2 2688,0 4090,0 2/0
10101 9 G 1,5 10,9 129,0 259,0 16 10189 5 G 70 44,7 3360,0 5443,0 2/0
10181 10 G 1,5 10,9 144,0 275,0 16 10195 3 G 95 41,3 2736,0 4680,0 3/0
10102 11 G 1,5 11,6 158,0 300,0 16 10165 4 G 95 46,0 3648,0 5540,0 3/0
10103 12 G 1,5 11,8 173,0 309,0 16 10333 5 G 95 50,7 4560,0 6931,0 3/0
10104 12 x 1,5 11,8 173,0 309,0 16 10166 4 G 120 51,0 4608,0 7000,0 4/0
10105 14 G 1,5 13,0 202,0 345,0 16 13139 4 G 150 57,2 5760,0 8340,0 300 kcmil
10106 16 G 1,5 13,9 230,0 386,0 16
13140 4 G 185 63,0 7104,0 9904,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

31
Flexible Control Cables / PVC Control Cables

JZ-500 black flexible, metermarking

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -15C to +80C compound type Z 7225 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage U0/U 300/500 V black cores with continuous white the wetting properties of lacquers
Test voltage 4000 V numbering UV- resistant
Breakdown voltage min. 8000 V GN-YE conductor, 3 cores and above Tests
Insulation resistance in the outer layer PVC self-extinguishing and flame retardant
min. 20 MOhm x km Cores stranded in layers with acc. to DIN VDE 0482-332-1-2,
Minimum bending radius optimal lay-length DIN EN 60332-1-2, IEC 60332-1 (equivalent
flexing 7,5x cable Outer sheath of special PVC DIN VDE 0472 part 804 test method B)
fixed installation 4x cable compound type TM2 to
Radiation resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1 Note
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour black (RAL 9005) G = with green-yellow conductor
with meter marking x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-500-C black, confer page 52

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms and in open air. Must not be laid directly in soil or water. When screened for measurement, control and control line etc. in mechanical
and plant engineering, machine tools, production lines and conveyor belts.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10340 2 x 0,5 5,4 9,6 40,0 20 10363 25 G 1 16,2 240,0 485,0 18
10341 3 G 0,5 5,7 14,4 46,0 20 10543 34 G 1 18,7 326,0 690,0 18
11630 3 x 0,5 5,7 14,4 46,0 20 10364 2 x 1,5 7,0 29,0 70,0 16
10342 4 G 0,5 6,1 19,0 56,0 20 10365 3 G 1,5 7,4 43,0 90,0 16
11631 4 x 0,5 6,1 19,0 56,0 20 11645 3 x 1,5 7,4 43,0 90,0 16
10343 5 G 0,5 6,8 24,0 65,0 20 10366 4 G 1,5 8,2 58,0 109,0 16
11632 5 x 0,5 6,8 24,0 65,0 20 11646 4 x 1,5 8,2 58,0 109,0 16
10344 7 G 0,5 7,3 33,6 80,0 20 10367 5 G 1,5 9,1 72,0 131,0 16
11633 7 x 0,5 7,3 33,6 80,0 20 11647 5 x 1,5 9,1 72,0 131,0 16
10345 12 G 0,5 9,6 58,0 135,0 20 10368 7 G 1,5 9,8 101,0 184,0 16
11634 12 x 0,5 9,6 58,0 135,0 20 11648 7 x 1,5 9,8 101,0 184,0 16
10346 18 G 0,5 11,5 86,0 196,0 20 10369 12 G 1,5 13,2 173,0 309,0 16
10347 25 G 0,5 13,5 120,0 270,0 20 11649 12 x 1,5 13,2 173,0 309,0 16
10348 2 x 0,75 5,9 14,4 46,0 19 10370 18 G 1,5 15,6 259,0 440,0 16
10349 3 G 0,75 6,2 21,6 54,0 19 10371 25 G 1,5 18,6 360,0 620,0 16
11635 3 x 0,75 6,2 21,6 54,0 19 10372 2 x 2,5 8,4 48,0 112,0 14
10350 4 G 0,75 6,7 28,8 66,0 19 10373 3 G 2,5 8,9 72,0 148,0 14
11636 4 x 0,75 6,7 28,8 66,0 19 11650 3 x 2,5 8,9 72,0 148,0 14
10351 5 G 0,75 7,5 36,0 80,0 19 10374 4 G 2,5 9,8 96,0 178,0 14
11637 5 x 0,75 7,5 36,0 80,0 19 11651 4 x 2,5 9,8 96,0 178,0 14
10352 7 G 0,75 8,3 50,0 110,0 19 10375 5 G 2,5 10,9 120,0 221,0 14
11638 7 x 0,75 8,3 50,0 110,0 19 11652 5 x 2,5 10,9 120,0 221,0 14
10353 12 G 0,75 10,8 86,0 179,0 19 10376 7 G 2,5 12,0 168,0 306,0 14
11639 12 x 0,75 10,8 86,0 179,0 19 11653 7 x 2,5 12,0 168,0 306,0 14
10354 18 G 0,75 12,8 130,0 257,0 19 10377 12 G 2,5 15,9 288,0 498,0 14
10355 25 G 0,75 15,1 180,0 365,0 19 11654 12 x 2,5 15,9 288,0 498,0 14
10356 2x1 6,2 19,2 60,0 18 10378 18 G 2,5 19,0 432,0 764,0 14
10357 3G1 6,5 29,0 72,0 18 10379 25 G 2,5 22,6 600,0 1044,0 14
11640 3x1 6,5 29,0 72,0 18 10380 4G4 11,5 154,0 295,0 12
10358 4G1 7,2 38,4 86,0 18 10381 5G4 12,8 192,0 361,0 12
11641 4x1 7,2 38,4 86,0 18 10382 4G6 13,6 230,0 424,0 10
10359 5G1 8,1 48,0 104,0 18 10383 5G6 15,1 288,0 525,0 10
11642 5x1 8,1 48,0 104,0 18 10384 4 G 10 17,1 384,0 701,0 8
10360 7G1 8,7 67,0 141,0 18 10388 5 G 10 18,9 480,0 909,0 8
11643 7x1 8,7 67,0 141,0 18 10385 4 G 16 20,9 614,0 1035,0 6
10361 12 G 1 11,4 115,0 230,0 18 10386 4 G 25 25,6 960,0 1582,0 4
11644 12 x 1 11,4 115,0 230,0 18 10387 4 G 35 29,4 1344,0 2105,0 2
10362 18 G 1 13,7 173,0 343,0 18

Dimensions and specifications may be changed without prior notice. (RA01)

32
Flexible Control Cables / PVC Control Cables

JZ-500 orange flexible, orange cores, control cable for interlocking purposes,
meter marking
A

Technical data Cable structure Properties


Special-PVC control cable for Bare copper-conductor, to Extensively oil resistant,
interlocking purposes adapted DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
to DIN VDE 0285-525-2-51/ BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
DIN EN 50525-2-51 Core insulation of special PVC The materials used in manufacture are
Temperature range compound type Z 7225 cadmium-free and contain no silicone
flexing -15C to +80C Core identification to DIN VDE 0293 and free from substances harmful to
fixed installation -40C to +80C orange cores with continuous black the wetting properties of lacquers
Nominal voltage U0/U 300/500 V numbering Tests
Test voltage 4000 V JZ-version with GN-YE conductor PVC self-extinguishing and flame retardant
Breakdown voltage min. 8000 V 3 cores and above acc. to DIN VDE 0482-332-1-2,
Insulation resistance OZ-version without GN-YE conductor DIN EN 60332-1-2, IEC 60332-1 (equivalent
min. 20 MOhm x km Cores stranded in layers with DIN VDE 0472 part 804 test method B)
Minimum bending radius optimal lay-length
flexing 7,5x cable Outer sheath of special PVC Note
fixed installation 4x cable compound type TM2 to G = with green-yellow conductor
Radiation resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1 x = without green-yellow conductor (OZ)
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour orange (RAL 2003) AWG sizes are approximate equivalent
with meter marking values. The actual cross-section is in mm.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, as control cable acc. to EN 60204 part 1 and VDE 0113 part 1. As per recommendation of the specified
standards the insulated conductors of control current circuits should be coloured orange, when they are used for interlocking purposes. These control
circuits are supplied with an external power and remain active under current when the main switch is disconnected or switched off.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10537 2x1 5,6 19,2 60,0 18 10546 4 G 1,5 7,4 58,0 109,0 16
10538 3G1 5,9 29,0 72,0 18 10547 5 G 1,5 8,3 72,0 131,0 16
10539 3x1 5,9 29,0 72,0 18 10747 3 G 2,5 8,3 72,0 148,0 14
10541 4x1 6,6 38,4 86,0 18 10748 4 G 2,5 9,2 96,0 178,0 14
10540 4G1 6,6 38,4 86,0 18 10749 5 G 2,5 10,1 120,0 221,0 14
10542 5G1 7,3 48,0 104,0 18
10544 2 x 1,5 6,4 29,0 70,0 16
10545 3 G 1,5 6,8 43,0 90,0 16

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

33
Flexible Control Cables / PVC Control Cables

JZ-500 COLD flexible at low temperature, number coded, meter marking

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -30C to +80C compound type YI4 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage U0/U 300/500 V black cores with continuous white the wetting properties of lacquers
Test voltage 4000 V numbering Tests
Breakdown voltage min. 8000 V GN-YE conductor, 3 cores and above PVC self-extinguishing and flame retardant
Insulation resistance in the outer layer acc. to DIN VDE 0482-332-1-2,
min. 20 MOhm x km Cores stranded in layers with DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius optimal lay-length DIN VDE 0472 part 804 test method B)
flexing 7,5x cable Outer sheath of cold flexible special PVC
fixed installation 4x cable Sheath colour black (RAL 9005) Note
Radiation resistance with meter marking G = with green-yellow conductor
up to 80x106 cJ/kg (up to 80 Mrad) x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced
motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production
streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient
and fast installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10750 2 x 0,5 4,8 9,6 40,0 20 10774 2 x 1,5 6,4 29,0 70,0 16
10751 3 G 0,75 5,6 21,6 54,0 19 10775 3 G 1,5 6,8 43,0 90,0 16
10752 3 x 0,75 5,6 21,6 54,0 19 10776 3 x 1,5 6,8 43,0 90,0 16
10753 4 G 0,75 6,3 28,8 66,0 19 10777 4 G 1,5 7,4 58,0 109,0 16
10754 4 x 0,75 6,3 29,0 66,0 19 10778 4 x 1,5 7,4 58,0 109,0 16
10755 5 G 0,75 6,9 36,0 80,0 19 10779 5 G 1,5 8,3 72,0 131,0 16
10756 5 x 0,75 6,9 36,0 80,0 19 10780 5 x 1,5 8,3 72,0 131,0 16
10757 7 G 0,75 7,5 50,0 110,0 19 10781 6 G 1,5 9,2 86,0 157,0 16
10758 7 x 0,75 7,5 50,0 110,0 19 10782 7 G 1,5 9,2 101,0 184,0 16
10759 12 G 0,75 9,8 86,0 179,0 19 10783 7 x 1,5 9,2 101,0 184,0 16
10760 18 G 0,75 12,2 130,0 257,0 19 10784 12 G 1,5 11,8 173,0 309,0 16
10761 25 G 0,75 14,3 180,0 365,0 19 10785 18 G 1,5 14,6 259,0 440,0 16
10762 2x1 5,6 19,2 60,0 18 10786 25 G 1,5 17,4 360,0 620,0 16
10763 3G1 5,9 29,0 72,0 18 10787 2 x 2,5 7,8 48,0 112,0 14
10764 3x1 5,9 29,0 72,0 18 10788 3 G 2,5 8,3 72,0 148,0 14
10765 4G1 6,6 38,4 86,0 18 10789 3 x 2,5 8,3 72,0 148,0 14
10766 4x1 6,6 38,4 86,0 18 10790 4 G 2,5 9,2 96,0 178,0 14
10767 5G1 7,3 48,0 104,0 18 10791 4 x 2,5 9,2 96,0 178,0 14
10768 5x1 7,3 48,0 104,0 18 10792 5 G 2,5 10,1 120,0 221,0 14
10769 7G1 8,1 67,0 141,0 18 10793 5 x 2,5 10,1 120,0 221,0 14
10770 7x1 8,1 67,0 141,0 18 10794 7 G 2,5 11,2 168,0 306,0 14
10771 12 G 1 10,4 115,0 230,0 18 10795 7 x 2,5 11,2 168,0 306,0 14
10772 18 G 1 12,9 173,0 343,0 18 10796 4G6 13,0 230,0 424,0 10
10773 25 G 1 15,4 240,0 485,0 18 10797 5G6 14,5 288,0 525,0 10

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

34
Flexible Control Cables / PVC Control Cables

H05VV5-F (NYSLY-JZ) flexible, number coded, oil resistant,


meter marking
A

Technical data Cable structure Properties


Spezial-PVC control cable with Bare copper-conductor, to The materials used in manufacture are
oil resistant outer sheath acc. to DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN VDE 0285-525-2-51 / BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
DIN EN 50525-2-51 and IEC 60227/75 Core insulation of special PVC the wetting properties of lacquers
Temperature range compound type TI2 to Tests
flexing -5C to +70C DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
fixed installation -40C to +70C Core identification to DIN VDE 0293 acc. to DIN VDE 0482-332-1-2,
Nominal voltage U0/U 300/500 V black cores with continuous white DIN EN 60332-1-2, IEC 60332-1 (equivalent
Test voltage 2 kV, 5 minutes numbering DIN VDE 0472 part 804 test method B)
Breakdown voltage min. 4000 V GN-YE conductor, 3 cores and above Oil resistant to DIN EN 60811-404
Insulation resistance in the outer layer
min. 20 MOhm x km Outer sheath of special PVC Note
Minimum bending radius compound type TM5 to G = with green-yellow conductor
flexing 7,5x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1 x = without green-yellow conductor (OZ)
fixed installation 4x cable Sheath colour grey (RAL 7001) AWG sizes are approximate equivalent
Radiation resistance with meter marking values. The actual cross-section is in mm.
up to 80x106 cJ/kg (up to 80 Mrad) screened analogue type:
H05VVC4V5-K (NYSLYCY-JZ),
confer page 57

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and
production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants
and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13122 2 x 0,5 5,2 - 6,6 9,7 46,0 20 13123 2 x 0,75 5,7 - 7,2 14,1 52,0 19
13001 3 G 0,5 5,5 - 7,0 14,4 54,0 20 13013 3 G 0,75 6,0 - 7,6 21,6 68,0 19
13002 4 G 0,5 6,2 - 7,9 19,0 65,0 20 13014 4 G 0,75 6,6 - 8,3 29,0 82,0 19
13003 5 G 0,5 6,8 - 8,6 24,0 80,0 20 13015 5 G 0,75 7,4 - 9,3 36,0 107,0 19
13004 6 G 0,5 7,6 - 9,6 29,0 104,0 20 13016 6 G 0,75 8,1 - 10,1 43,0 132,0 19
13005 7 G 0,5 8,3 - 10,4 33,6 119,0 20 13017 7 G 0,75 9,0 - 11,3 50,0 145,0 19
13920 8 G 0,5 9,2 - 11,5 38,0 134,0 20 13926 8 G 0,75 9,9 - 12,3 58,0 189,0 19
13006 9 G 0,5 10,1 - 12,5 43,0 136,0 20 13018 9 G 0,75 10,6 - 13,2 65,0 194,0 19
13921 10 G 0,5 10,9 - 13,6 48,0 166,0 20 13019 12 G 0,75 11,0 - 13,7 86,0 231,0 19
13007 12 G 0,5 10,4 - 12,9 58,0 186,0 20 13927 14 G 0,75 11,7 - 14,5 101,0 274,0 19
13922 14 G 0,5 10,9 - 13,6 67,0 215,0 20 13020 18 G 0,75 13,2 - 16,4 130,0 313,0 19
13008 18 G 0,5 12,3 - 15,3 86,0 251,0 20 13021 25 G 0,75 15,8 - 19,5 180,0 461,0 19
13009 25 G 0,5 14,8 - 18,2 120,0 349,0 20 13928 27 G 0,75 16,2 - 19,9 195,0 493,0 19
13923 27 G 0,5 15,1 - 18,6 129,6 373,0 20 13022 34 G 0,75 18,4 - 22,6 245,0 614,0 19
13010 34 G 0,5 17,2 - 21,2 163,0 480,0 20 13929 36 G 0,75 18,2 - 22,4 259,0 646,0 19
13924 36 G 0,5 17,0 - 20,9 172,0 510,0 20 13126 41 G 0,75 20,1 - 24,6 295,0 730,0 19
13125 41 G 0,5 18,8 - 23,1 196,0 570,0 20 13023 50 G 0,75 21,9 - 26,8 360,0 896,0 19
13011 50 G 0,5 20,5 - 25,2 240,0 658,0 20 13024 61 G 0,75 23,4 - 28,7 439,0 1030,0 19
13012 61 G 0,5 22,0 - 26,9 293,0 780,0 20 13930 65 G 0,75 24,4 - 29,8 468,0 1071,0 19
13925 65 G 0,5 22,8 - 28,0 312,0 810,0 20

Continuation

35
Flexible Control Cables / PVC Control Cables

H05VV5-F (NYSLY-JZ) flexible, number coded, oil resistant,


meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13119 2x1 5,9 - 7,5 19,0 66,0 18 13943 2 x 2,5 8,4 - 10,6 48,0 110,0 14
13025 3G1 6,3 - 8,0 29,0 78,0 18 13050 3 G 2,5 9,2 - 11,4 72,0 154,0 14
13026 4G1 6,9 - 8,7 38,0 104,0 18 13051 4 G 2,5 10,1 - 12,5 96,0 212,0 14
13027 5G1 7,8 - 9,8 48,0 123,0 18 13052 5 G 2,5 11,2 - 13,9 120,0 242,0 14
13028 6G1 8,7 - 10,8 58,0 152,0 18 13053 7 G 2,5 13,6 - 16,8 168,0 350,0 14
13029 7G1 9,5 - 11,8 67,0 183,0 18 13945 8 G 2,5 14,9 - 18,3 192,0 379,0 14
13931 8G1 10,5 - 13,0 77,0 220,0 18 13054 12 G 2,5 16,8 - 20,6 288,0 543,0 14
13030 9G1 11,4 - 14,0 86,0 230,0 18 13946 14 G 2,5 17,8 - 20,6 336,0 611,0 14
13031 12 G 1 11,8 - 14,6 115,0 269,0 18 13055 18 G 2,5 20,2 - 24,8 432,0 787,0 14
13932 14 G 1 12,6 - 14,6 134,0 361,0 18 13056 25 G 2,5 24,2 - 29,6 600,0 1175,0 14
13032 18 G 1 14,0 - 17,2 173,0 400,0 18 13947 27 G 2,5 24,7 - 30,2 648,0 1280,0 14
13933 19 G 1 13,6 - 16,8 183,0 413,0 18 13057 34 G 2,5 28,2 - 34,5 816,0 1529,0 14
13033 25 G 1 16,9 - 20,8 240,0 546,0 18 13948 36 G 2,5 28,0 - 34,2 864,0 1791,0 14
13934 27 G 1 17,0 - 21,0 259,0 582,0 18 13949 41 G 2,5 30,4 - 37,1 984,0 1905,0 14
13034 34 G 1 19,7 - 24,1 326,0 724,0 18 13058 50 G 2,5 33,0 - 40,3 1200,0 2290,0 14
13124 36 G 1 19,4 - 23,8 348,0 775,0 18 13059 61 G 2,5 35,0 - 42,7 1464,0 2724,0 14
13935 37 G 1 19,4 - 23,8 355,0 785,0 18
13127 41 G 1 21,4 - 26,2 392,0 822,0 18
13035 50 G 1 23,3 - 28,5 480,0 1052,0 18
13036 61 G 1 25,0 - 30,6 586,0 1265,0 18
13936 65 G 1 25,2 - 30,8 624,0 1315,0 18
13120 2 x 1,5 6,8 - 8,6 29,0 77,0 16
13037 3 G 1,5 7,4 - 9,4 43,0 97,0 16
13038 4 G 1,5 8,2 - 10,2 58,0 128,0 16
13039 5 G 1,5 9,1 - 11,4 72,0 149,0 16
13040 6 G 1,5 10,2 - 12,6 86,0 196,0 16
13041 7 G 1,5 11,3 - 14,1 101,0 216,0 16
13937 8 G 1,5 12,2 - 15,1 115,0 271,0 16
13042 9 G 1,5 13,3 - 16,5 130,0 282,0 16
13043 12 G 1,5 13,8 - 17,0 173,0 324,0 16
13121 14 G 1,5 14,7 - 18,1 202,0 372,0 16
13044 18 G 1,5 16,5 - 20,3 259,0 485,0 16
13938 19 G 1,5 16,7 - 20,5 274,0 495,0 16
13045 25 G 1,5 19,9 - 24,4 360,0 671,0 16
13939 27 G 1,5 20,3 - 24,9 389,0 695,0 16
13046 32 G 1,5 22,2 - 27,1 461,0 820,0 16
13047 34 G 1,5 23,0 - 28,2 490,0 881,0 16
13940 36 G 1,5 23,0 - 28,2 518,0 905,0 16
13941 37 G 1,5 23,0 - 28,2 532,0 920,0 16
13128 41 G 1,5 25,2 - 30,9 590,0 1085,0 16
13048 50 G 1,5 27,7 - 33,9 720,0 1381,0 16
13049 61 G 1,5 29,4 - 35,8 878,0 1640,0 16
13942 65 G 1,5 30,3 - 37,0 963,0 1730,0 16

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

36
Flexible Control Cables / PVC Control Cables

(H)05VV5-F ((N)YSLY-JZ) flexible, number coded, oil resistant,


meter marking
A

Technical data Cable structure Properties


Spezial-PVC control cable with Bare copper-conductor, to The materials used in manufacture are
oil resistant outer sheath adapted to DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN VDE 0285-525-2-51 / BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
DIN EN 50525-2-51 and IEC 60227/75 Core insulation of special PVC the wetting properties of lacquers
deviation of conductor cross sections compound type TI2 to Tests
Temperature range DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
flexing -5C to +70C Core identification to DIN VDE 0293 acc. to DIN VDE 0482-332-1-2,
fixed installation -40C to +70C black cores with continuous white DIN EN 60332-1-2, IEC 60332-1 (equivalent
Nominal voltage U0/U 300/500 V numbering DIN VDE 0472 part 804 test method B)
Test voltage 2 kV, 5 minutes GN-YE conductor, 3 cores and above Oil resistant to DIN EN 60811-404
Breakdown voltage min. 4000 V in the outer layer
Insulation resistance Cores stranded in layers with Note
min. 20 MOhm x km optimal lay-length G = with green-yellow conductor
Minimum bending radius Outer sheath of special PVC x = without green-yellow conductor (OZ)
flexing 7,5x cable compound type TM5 to AWG sizes are approximate equivalent
fixed installation 4x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1 values. The actual cross-section is in mm.
Radiation resistance Sheath colour grey (RAL 7001) screened analogue type:
up to 80x106 cJ/kg (up to 80 Mrad) with meter marking (H)05VVC4V5-K, confer page 59

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and
production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants
and car washing stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
13133 2x4 10,7 77,0 195,0 12 13153 3 G 16 18,8 461,0 827,0 6
13134 3G4 11,3 115,0 230,0 12 13154 4 G 16 20,9 614,0 1035,0 6
13135 4G4 12,4 154,0 295,0 12 13155 5 G 16 23,4 768,0 1259,0 6
13136 5G4 13,9 192,0 361,0 12 13156 7 G 16 28,5 1075,0 1780,0 6
13138 7G4 16,6 269,0 466,0 12 13159 4 G 25 26,3 960,0 1582,0 4
13141 12 G 4 20,8 461,0 810,0 12 13160 5 G 25 29,5 1200,0 1852,0 4
13142 2x6 12,0 116,0 280,0 10 13161 3 G 35 26,5 1008,0 1614,0 2
13143 3G6 12,9 173,0 358,0 10 13162 4 G 35 29,5 1344,0 2110,0 2
13144 4G6 14,2 230,0 424,0 10 13163 5 G 35 32,8 1680,0 2652,0 2
13145 5G6 15,9 288,0 525,0 10 13164 3 G 50 32,2 1440,0 2560,0 1
13146 7G6 18,9 403,0 625,0 10 13165 4 G 50 36,1 1920,0 2972,0 1
13148 3 G 10 16,3 288,0 540,0 8 13166 5 G 50 40,3 2400,0 3948,0 1
13149 4 G 10 18,1 384,0 701,0 8
13150 5 G 10 20,3 480,0 858,0 8
13151 7 G 10 24,3 672,0 1106,0 8

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

37
Flexible Control Cables / PVC Control Cables

JZ-750 flexible, number coded, 750 V, meter marking

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -15C to +80C compound type TI2 to cadmium-free and contain no silicone
fixed installation -40C to +80C DIN VDE 0207-363-3/DIN EN 50363-3 and free from substances harmful to
Nominal voltage U0/U 450/750 V Core identification to DIN VDE 0293 the wetting properties of lacquers
Test voltage 4000 V black cores with continuous white Tests
Breakdown voltage min. 8000 V numbering PVC self-extinguishing and flame retardant
Insulation resistance GN-YE conductor, 3 cores and above acc. to DIN VDE 0482-332-1-2,
min. 20 MOhm x km in the outer layer DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius Cores stranded in layers with DIN VDE 0472 part 804 test method B)
flexing 7,5x cable optimal lay-length
fixed installation 4x cable Outer sheath of special PVC Note
Radiation resistance compound type TM2 to G = with green-yellow conductor
up to 80x106 cJ/kg (up to 80 Mrad) DIN VDE 0207-363-4-1/DIN EN 50363-4-1 x = without green-yellow conductor (OZ)
Sheath colour grey (RAL 7001) Cleanroom qualification tested with analog
with meter marking type. Please note "cleanroom qualified"
when ordering.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, wherever internationally recognized PVC cables are required. E. g. as a control or measurements cable
on industrial machinery, on conveyor systems or in industrial plants, etc. The number coding has been brought onto the cores in such a way that it is
easily identifiable and the core numbers are individually underlined to avoid confusion. The green-yellow earth core is laid in the outer layer.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10800 2 x 0,5 5,7 9,6 48,0 20 10834 3G1 7,0 29,0 92,0 18
10801 3 G 0,5 6,0 14,5 65,0 20 10835 3x1 7,0 29,0 92,0 18
10802 4 G 0,5 6,8 20,0 81,0 20 10836 4G1 7,8 39,0 122,0 18
10803 5 G 0,5 7,4 24,0 98,0 20 10837 4x1 7,8 39,0 122,0 18
10804 7 G 0,5 8,3 34,0 123,0 20 10838 5G1 8,6 48,0 137,0 18
10805 8 G 0,5 9,1 38,0 155,0 20 10839 7G1 9,5 68,0 186,0 18
10806 10 G 0,5 10,0 48,0 180,0 20 10840 7x1 9,5 68,0 186,0 18
10807 12 G 0,5 10,8 58,0 208,0 20 10841 8G1 10,3 77,0 240,0 18
10808 14 G 0,5 11,7 67,0 248,0 20 10842 12 G 1 12,7 116,0 293,0 18
10809 16 G 0,5 12,5 76,0 260,0 20 10843 14 G 1 13,4 134,0 340,0 18
10810 18 G 0,5 13,2 87,0 285,0 20 10844 16 G 1 14,4 154,0 400,0 18
10811 21 G 0,5 13,8 96,0 375,0 20 10845 18 G 1 15,1 173,0 437,0 18
10812 25 G 0,5 15,5 118,0 400,0 20 10846 21 G 1 16,1 205,0 505,0 18
10813 30 G 0,5 16,6 144,0 475,0 20 10847 25 G 1 18,0 240,0 606,0 18
10814 40 G 0,5 18,7 192,0 590,0 20 10848 34 G 1 20,9 326,0 770,0 18
10815 50 G 0,5 21,5 240,0 710,0 20 10849 41 G 1 22,6 394,0 880,0 18
10816 61 G 0,5 23,0 293,0 880,0 20 10850 50 G 1 24,8 480,0 1400,0 18
10817 2 x 0,75 6,2 15,0 60,0 19 10851 61 G 1 26,5 586,0 1450,0 18
10818 3 G 0,75 6,5 22,0 78,0 19 10852 2 x 1,5 7,2 29,0 90,0 16
10819 4 G 0,75 7,3 29,0 104,0 19 10853 3 G 1,5 7,8 43,0 120,0 16
10820 5 G 0,75 8,0 36,0 116,0 19 10854 3 x 1,5 7,8 43,0 120,0 16
10821 7 G 0,75 8,9 51,0 148,0 19 10855 4 G 1,5 8,5 58,0 150,0 16
10822 8 G 0,75 9,6 58,0 160,0 19 10856 4 x 1,5 8,5 58,0 155,0 16
10823 10 G 0,75 10,7 72,0 195,0 19 10857 5 G 1,5 9,6 72,0 177,0 16
10824 12 G 0,75 11,6 87,0 248,0 19 10858 7 G 1,5 10,4 101,0 220,0 16
10825 15 G 0,75 13,2 108,0 295,0 19 10859 8 G 1,5 11,4 115,0 248,0 16
10826 18 G 0,75 14,1 130,0 346,0 19 10860 9 G 1,5 12,5 130,0 278,0 16
10827 21 G 0,75 14,8 151,0 395,0 19 10861 12 G 1,5 14,1 173,0 364,0 16
10828 25 G 0,75 16,6 180,0 505,0 19 10862 14 G 1,5 14,9 202,0 390,0 16
10829 34 G 0,75 19,3 245,0 684,0 19 10863 16 G 1,5 16,0 230,0 490,0 16
10830 41 G 0,75 20,9 296,0 780,0 19 10864 18 G 1,5 17,0 259,0 550,0 16
10831 50 G 0,75 22,9 360,0 940,0 19 10865 21 G 1,5 18,0 302,0 670,0 16
10832 61 G 0,75 24,5 440,0 1125,0 19 10866 25 G 1,5 20,2 360,0 745,0 16
10833 2x1 6,6 20,0 80,0 18 10867 32 G 1,5 22,6 461,0 810,0 16

Continuation

38
Flexible Control Cables / PVC Control Cables

JZ-750 flexible, number coded, 750 V, meter marking

Part no. No.cores x


cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No. Part no. No.cores x
cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No.
A
10868 34 G 1,5 23,4 490,0 1010,0 16 10876 7 G 2,5 12,6 168,0 350,0 14
10869 42 G 1,5 25,5 605,0 1115,0 16 10877 12 G 2,5 16,9 288,0 600,0 14
10870 50 G 1,5 27,9 720,0 1430,0 16 10878 14 G 2,5 18,2 336,0 870,0 14
10871 61 G 1,5 30,0 878,0 1750,0 16 10879 18 G 2,5 20,4 432,0 1050,0 14
10872 2 x 2,5 8,6 48,0 110,0 14 10880 25 G 2,5 24,4 600,0 1170,0 14
10873 3 G 2,5 9,3 72,0 190,0 14
10874 4 G 2,5 10,2 96,0 240,0 14
10875 5 G 2,5 11,4 120,0 270,0 14

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

39
Flexible Control Cables / PVC Control Cables

JZ-600 flexible, number coded, 0,6/1kV, meter marking

Technical data Cable structure Properties


Special PVC control cable Bare copper-conductor, to Extensively oil resistant,
adapted to DIN VDE 0262 DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
and DIN VDE 0285-525-2-51 / BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
DIN EN 50525-2-51, Core insulation of special PVC The materials used in manufacture are
with insulation wall thickness for 1 kV compound type TI2 to cadmium-free and contain no silicone
Temperature range DIN VDE 0207-363-3 / DIN EN 50363-3 and free from substances harmful to
flexing -15C to +80C Core identification to DIN VDE 0293 the wetting properties of lacquers
fixed installation -40C to +80C black cores with continuous white UV- resistant
Nominal voltage U0/U 0,6/1 kV numbering Tests
Test voltage 4000 V GN-YE conductor, 3 cores and above PVC self-extinguishing and flame retardant
Breakdown voltage min. 8000 V in the outer layer acc. to DIN VDE 0482-332-1-2,
Insulation resistance Cores stranded in layers with DIN EN 60332-1-2, IEC 60332-1 (equivalent
min. 20 MOhm x km optimal lay-length DIN VDE 0472 part 804 test method B)
Minimum bending radius Outer sheath of special PVC
flexing 7,5x cable compound type TM2 to Note
fixed installation 4x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1 G = with green-yellow conductor
Radiation resistance Sheath colour black (RAL 9005) x = without green-yellow conductor (OZ)
up to 80x106 cJ/kg (up to 80 Mrad) with meter marking AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-600-Y-CY, confer page 60

Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning
and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable
from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily
identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is
located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and
Arabian countries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10550 2 x 0,5 6,3 9,6 56,0 20 10582 2 x 0,75 6,6 14,4 66,0 19
10551 3 G 0,5 6,6 14,4 68,0 20 10583 3 G 0,75 6,9 21,6 74,0 19
10552 3 x 0,5 6,6 14,4 68,0 20 10584 3 x 0,75 6,9 21,6 74,0 19
10553 4 G 0,5 7,2 19,0 100,0 20 10585 4 G 0,75 7,5 29,0 126,0 19
10554 4 x 0,5 7,2 19,0 100,0 20 10586 4 x 0,75 7,5 29,0 126,0 19
10555 5 G 0,5 8,0 24,0 117,0 20 10587 5 G 0,75 8,4 36,0 140,0 19
10556 5 x 0,5 8,0 24,0 117,0 20 10588 5 x 0,75 8,4 36,0 140,0 19
10557 6 G 0,5 8,7 29,0 126,0 20 10589 6 G 0,75 9,3 43,0 170,0 19
10558 7 G 0,5 8,7 33,6 138,0 20 10590 6 x 0,75 9,3 43,0 170,0 19
10559 7 x 0,5 8,7 33,6 138,0 20 10591 7 G 0,75 9,3 50,0 190,0 19
10560 8 G 0,5 9,5 38,0 150,0 20 10592 7 x 0,75 9,3 50,0 190,0 19
10561 8 x 0,5 9,5 38,0 150,0 20 10593 8 G 0,75 10,3 58,0 212,0 19
10562 10 G 0,5 10,3 48,0 176,0 20 10594 8 x 0,75 10,3 58,0 212,0 19
10563 12 G 0,5 11,2 58,0 200,0 20 10595 9 G 0,75 11,0 65,0 227,0 19
10564 12 x 0,5 11,2 58,0 200,0 20 10596 10 G 0,75 11,0 72,0 238,0 19
10565 14 G 0,5 12,3 67,0 230,0 20 10597 12 G 0,75 12,0 86,0 257,0 19
10566 16 G 0,5 12,9 76,0 250,0 20 10598 12 x 0,75 12,0 86,0 257,0 19
10567 18 G 0,5 13,8 86,0 276,0 20 10599 14 G 0,75 12,9 101,0 286,0 19
10568 20 G 0,5 14,4 96,0 293,0 20 10600 15 G 0,75 13,8 108,0 319,0 19
10569 21 G 0,5 14,4 96,0 305,0 20 10601 18 G 0,75 14,5 130,0 362,0 19
10570 25 G 0,5 16,1 120,0 335,0 20 10602 20 G 0,75 15,4 144,0 394,0 19
10571 30 G 0,5 17,2 144,0 348,0 20 10603 21 G 0,75 15,4 151,0 422,0 19
10572 32 G 0,5 18,0 154,0 355,0 20 10604 25 G 0,75 17,2 180,0 486,0 19
10573 34 G 0,5 18,7 163,0 520,0 20 10605 32 G 0,75 19,0 230,0 595,0 19
10574 40 G 0,5 19,5 192,0 590,0 20 10606 34 G 0,75 19,9 245,0 638,0 19
10575 42 G 0,5 20,1 202,0 595,0 20 10607 37 G 0,75 19,9 260,0 696,0 19
10576 50 G 0,5 22,1 240,0 715,0 20 10608 40 G 0,75 20,7 288,0 726,0 19
10577 52 G 0,5 22,1 252,0 740,0 20 10609 41 G 0,75 21,6 296,0 750,0 19
10578 61 G 0,5 23,6 293,0 840,0 20 10610 42 G 0,75 21,6 302,0 770,0 19
10579 65 G 0,5 24,4 312,0 880,0 20 10611 50 G 0,75 23,7 360,0 895,0 19
10580 80 G 0,5 27,2 384,0 960,0 20 10612 61 G 0,75 25,3 439,0 1070,0 19
10581 100 G 0,5 31,2 480,0 1050,0 20 10613 65 G 0,75 26,3 468,0 1110,0 19
10614 80 G 0,75 28,9 576,0 1500,0 19
10615 100 G 0,75 32,2 720,0 1889,0 19

Continuation

40
Flexible Control Cables / PVC Control Cables

JZ-600 flexible, number coded, 0,6/1kV, meter marking


Part no. No.cores x
cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No. Part no. No.cores x
cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No.
A
10616 2x1 7,0 19,2 80,0 18 10690 3 G 2,5 10,1 72,0 175,0 14
10617 3G1 7,4 29,0 96,0 18 10691 3 x 2,5 10,1 72,0 175,0 14
10618 3x1 7,4 29,0 96,0 18 10692 4 G 2,5 11,2 96,0 203,0 14
10619 4G1 8,2 38,4 100,0 18 10693 4 x 2,5 11,2 96,0 203,0 14
10620 4x1 8,2 38,4 100,0 18 10694 5 G 2,5 12,5 120,0 251,0 14
10621 5G1 9,2 48,0 130,0 18 10695 5 x 2,5 12,5 120,0 251,0 14
10622 5x1 9,2 48,0 130,0 18 10696 7 G 2,5 13,8 168,0 330,0 14
10623 6G1 9,9 58,0 150,0 18 10697 7 x 2,5 13,8 168,0 330,0 14
10624 7G1 9,9 67,0 170,0 18 10698 8 G 2,5 15,1 192,0 400,0 14
10625 7x1 9,9 67,0 170,0 18 10699 12 G 2,5 18,3 288,0 553,0 14
10626 8G1 10,9 77,0 230,0 18 10700 14 G 2,5 19,6 336,0 630,0 14
10627 9G1 11,9 86,0 250,0 18 10701 18 G 2,5 22,0 432,0 795,0 14
10628 10 G 1 11,9 96,0 270,0 18 10702 21 G 2,5 23,3 504,0 930,0 14
10629 10 x 1 11,9 96,0 270,0 18 10703 25 G 2,5 26,2 600,0 1110,0 14
10630 12 G 1 12,8 115,0 290,0 18 10704 34 G 2,5 30,4 816,0 1450,0 14
10631 12 x 1 12,8 115,0 290,0 18 10705 42 G 2,5 33,0 1008,0 1750,0 14
10632 14 G 1 14,0 134,0 320,0 18 10706 50 G 2,5 36,2 1200,0 2100,0 14
10633 16 G 1 14,8 154,0 360,0 18 10707 61 G 2,5 38,8 1464,0 2540,0 14
10634 18 G 1 15,7 173,0 405,0 18 10708 100 G 2,5 49,8 2400,0 3850,0 14
10635 18 x 1 15,7 173,0 405,0 18 10709 2x4 11,0 77,0 180,0 12
10636 20 G 1 16,7 192,0 450,0 18 10710 3G4 11,7 115,0 230,0 12
10637 20 x 1 16,7 192,0 480,0 18 10711 4G4 12,9 154,0 310,0 12
10638 21 G 1 16,7 205,0 510,0 18 10712 5G4 14,4 192,0 410,0 12
10639 24 G 1 18,4 236,0 550,0 18 10713 7G4 15,8 269,0 540,0 12
10640 25 G 1 18,6 240,0 570,0 18 10714 8G4 17,5 307,0 710,0 12
10641 25 x 1 18,6 240,0 570,0 18 10715 12 G 4 21,0 461,0 860,0 12
10642 26 G 1 18,8 252,0 590,0 18 10716 3G6 13,1 173,0 370,0 10
10643 30 x 1 19,8 308,0 650,0 18 10717 4G6 14,5 230,0 430,0 10
10644 34 G 1 21,5 326,0 750,0 18 10718 5G6 16,2 288,0 650,0 10
10645 36 G 1 21,5 346,0 790,0 18 10719 7G6 18,0 403,0 860,0 10
10646 40 G 1 22,5 384,0 850,0 18 10720 3 G 10 16,8 288,0 660,0 8
10647 40 x 1 22,5 384,0 850,0 18 10721 4 G 10 18,5 384,0 790,0 8
10648 41 G 1 23,3 394,0 890,0 18 10722 5 G 10 20,5 480,0 960,0 8
10649 42 G 1 23,3 403,0 900,0 18 10723 7 G 10 22,5 672,0 1300,0 8
10650 50 G 1 25,6 480,0 1100,0 18 10724 3 G 16 20,2 461,0 700,0 6
10651 56 G 1 26,4 538,0 1190,0 18 10725 4 G 16 22,4 614,0 1100,0 6
10652 61 G 1 27,3 586,0 1266,0 18 10726 5 G 16 25,0 768,0 1600,0 6
10653 65 G 1 28,3 628,0 1560,0 18 10727 7 G 16 27,4 1075,0 1890,0 6
10654 80 G 1 31,4 786,0 1810,0 18 10728 3 G 25 24,8 720,0 1450,0 4
10655 100 G 1 35,0 960,0 1950,0 18 10729 4 G 25 27,4 960,0 1600,0 4
10656 2 x 1,5 8,2 29,0 95,0 16 10730 5 G 25 30,5 1200,0 2050,0 4
10657 3 G 1,5 8,6 43,0 112,0 16 10731 7 G 25 33,8 1680,0 2900,0 4
10658 3 x 1,5 8,6 43,0 112,0 16 10732 3 G 35 27,4 1008,0 1900,0 2
10659 4 G 1,5 9,6 58,0 139,0 16 10733 4 G 35 30,3 1344,0 2400,0 2
10660 4 x 1,5 9,6 58,0 139,0 16 10734 5 G 35 33,6 1680,0 2900,0 2
10661 5 G 1,5 10,7 72,0 170,0 16 10735 3 G 50 32,4 1440,0 2700,0 1
10662 5 x 1,5 10,7 72,0 170,0 16 10736 4 G 50 35,8 1920,0 3400,0 1
10663 6 G 1,5 11,6 86,0 190,0 16 10742 5 G 50 40,0 2400,0 4361,0 1
10664 7 G 1,5 11,6 101,0 225,0 16 10737 3 G 70 36,8 2016,0 3300,0 2/0
10665 7 x 1,5 11,6 101,0 225,0 16 10738 4 G 70 40,8 2688,0 4400,0 2/0
10666 8 G 1,5 12,9 115,0 250,0 16 10743 5 G 70 45,2 3360,0 5807,0 2/0
10667 9 G 1,5 13,9 130,0 280,0 16 10739 3 G 95 41,7 2736,0 5050,0 3/0
10668 10 G 1,5 13,9 144,0 300,0 16 10740 4 G 95 46,2 3648,0 6010,0 3/0
10669 11 G 1,5 14,8 158,0 330,0 16 10744 5 G 95 51,7 4560,0 7752,0 3/0
10670 12 G 1,5 15,0 173,0 370,0 16 10741 4 G 120 51,6 4608,0 7500,0 4/0
10671 12 x 1,5 15,5 173,0 370,0 16 10745 4 G 150 58,5 5760,0 8640,0 300 kcmil
10672 14 G 1,5 16,6 202,0 400,0 16
10746 4 G 185 63,3 7104,0 10380,0 350 kcmil
10673 16 G 1,5 17,5 230,0 450,0 16
10674 18 G 1,5 18,6 259,0 520,0 16
10675 19 G 1,5 18,6 279,0 550,0 16
10676 20 G 1,5 19,7 288,0 600,0 16
10677 21 G 1,5 19,7 302,0 600,0 16
10678 25 G 1,5 22,5 360,0 730,0 16
10679 32 G 1,5 24,3 461,0 880,0 16
10680 34 G 1,5 25,3 490,0 950,0 16
10681 40 G 1,5 26,6 576,0 990,0 16
10682 42 G 1,5 27,4 605,0 1120,0 16
10683 50 G 1,5 30,2 720,0 1400,0 16
10684 56 G 1,5 31,2 806,0 1530,0 16
10685 61 G 1,5 32,2 878,0 1700,0 16
10686 65 G 1,5 33,5 936,0 1900,0 16
10687 80 G 1,5 36,9 1152,0 2300,0 16
10688 100 G 1,5 41,3 1440,0 2700,0 16
10689 2 x 2,5 9,6 48,0 160,0 14

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

41
Flexible Control Cables / PVC Control Cables

JB-500 flexible, colour coded, metermarking

Technical data Cable structure Properties


Adapted to DIN VDE 0285-525-2-11/ Bare copper-conductor, to Extensively oil resistant,
DIN EN 50525-2-11 DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
Temperature range BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
flexing -15C to +80C Core insulation of special PVC The materials used in manufacture are
fixed installation -40C to +80C compound type Z 7225 cadmium-free and contain no silicone
Nominal voltage U0/U 300/500 V Core identification to JB/OB colour code and free from substances harmful to
Test voltage 4000 V GN-YE conductor, 3 cores and above the wetting properties of lacquers
Breakdown voltage min. 8000 V in the outer layer Tests
Insulation resistance Cores stranded in layers with PVC self-extinguishing and flame retardant
min. 20 MOhm x km optimal lay-length acc. to DIN VDE 0482-332-1-2,
Minimum bending radius Outer sheath of special PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
flexing 7,5x cable compound type TM2 to DIN VDE 0472 part 804 test method B)
fixed installation 4x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Radiation resistance Sheath colour grey (RAL 7001) Note
up to 80x106 cJ/kg (up to 80 Mrad) with meter marking G = with green-yellow conductor
from 5 cores with VDE-Reg-Nr. x = without green-yellow conductor (OB).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
Y-CY-JB , confer page 62

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, as measuring and control cables in tool machinery, conveyor belts, production lines, as well as in machinery
production, in air-conditioning and steel production plants. The earth core is located immediately below the outer sheath. JB cables are suitable for
use in all electrical equipment either in dry or damp areas. They should not, however, be installed in the open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11001 2 x 0,5 4,8 9,6 40,0 20 11057 6G1 8,1 58,0 125,0 18
11002 3 G 0,5 5,1 14,4 46,0 20 11058 6x1 8,1 58,0 125,0 18
11003 3 x 0,5 5,1 14,4 46,0 20 11059 7G1 8,1 67,0 141,0 18
11004 4 G 0,5 5,5 19,2 56,0 20 11060 7x1 8,1 67,0 141,0 18
11005 4 x 0,5 5,5 19,2 56,0 20 11061 8G1 8,8 77,0 175,0 18
11006 5 G 0,5 6,2 24,0 65,0 20 11062 9G1 9,7 87,0 200,0 18
11007 5 x 0,5 6,2 24,0 65,0 20 11063 10 G 1 9,8 96,0 207,0 18
11008 6 G 0,5 6,7 29,0 75,0 20 11064 12 G 1 10,4 115,0 230,0 18
11009 7 G 0,5 6,7 34,0 80,0 20 11065 14 G 1 11,4 134,0 271,0 18
11010 7 x 0,5 6,7 34,0 84,0 20 11066 16 G 1 12,3 154,0 300,0 18
11011 8 G 0,5 7,4 38,0 97,0 20 11067 18 G 1 12,9 173,0 343,0 18
11012 10 G 0,5 8,2 48,0 116,0 20 11068 20 G 1 13,8 192,0 375,0 18
11013 12 G 0,5 8,7 58,0 135,0 20 11069 24 G 1 15,1 230,0 468,0 18
11014 14 G 0,5 9,5 67,0 150,0 20 11070 25 G 1 15,4 240,0 485,0 18
11015 16 G 0,5 10,0 77,0 172,0 20 11077 2 x 1,5 6,4 29,0 70,0 16
11019 30 G 0,5 13,5 144,0 310,0 20 11078 3 G 1,5 6,8 43,0 90,0 16
11026 2 x 0,75 5,3 14,4 46,0 19 11079 3 x 1,5 6,8 43,0 90,0 16
11027 3 G 0,75 5,6 21,6 54,0 19 11080 4 G 1,5 7,4 58,0 109,0 16
11028 3 x 0,75 5,6 21,6 54,0 19 11081 4 x 1,5 7,4 58,0 109,0 16
11029 4 G 0,75 6,3 28,8 66,0 19 11082 5 G 1,5 8,3 72,0 131,0 16
11030 4 x 0,75 6,3 28,8 66,0 19 11083 5 x 1,5 8,3 72,0 131,0 16
11031 5 G 0,75 6,9 36,0 80,0 19 11084 6 G 1,5 9,2 86,4 157,0 16
11032 5 x 0,75 6,9 36,0 80,0 19 11085 7 G 1,5 9,2 101,0 184,0 16
11033 6 G 0,75 7,5 43,2 99,0 19 11086 7 x 1,5 9,2 101,0 184,0 16
11034 7 G 0,75 7,5 50,0 110,0 19 11087 8 G 1,5 10,0 115,0 216,0 16
11035 7 x 0,75 7,5 50,0 110,0 19 11088 11 G 1,5 11,6 158,0 300,0 16
11036 8 G 0,75 8,3 58,0 130,0 19 11089 12 G 1,5 11,8 173,0 309,0 16
11037 9 G 0,75 8,9 65,0 153,0 19 11090 14 G 1,5 13,0 202,0 345,0 16
11038 10 G 0,75 9,2 72,0 162,0 19 11091 16 G 1,5 13,9 230,0 386,0 16
11039 12 G 0,75 9,8 86,0 179,0 19 11092 18 G 1,5 14,6 259,0 440,0 16
11040 15 G 0,75 11,4 108,0 218,0 19 11093 20 G 1,5 15,6 288,0 490,0 16
11041 18 G 0,75 12,2 130,0 257,0 19 11094 25 G 1,5 17,4 360,0 620,0 16
11042 21 G 0,75 12,7 151,0 320,0 19 11104 2 x 2,5 7,8 48,0 112,0 14
11043 25 G 0,75 14,3 180,0 365,0 19 11105 3 G 2,5 8,3 72,0 148,0 14
11050 2x1 5,6 19,2 60,0 18 11106 3 x 2,5 8,3 72,0 148,0 14
11051 3G1 5,9 29,0 72,0 18 11107 4 G 2,5 9,2 96,0 178,0 14
11052 3x1 5,9 29,0 72,0 18 11108 4 x 2,5 9,2 96,0 178,0 14
11053 4G1 6,6 38,4 86,0 18 11109 5 G 2,5 10,1 120,0 221,0 14
11054 4x1 6,6 38,4 86,0 18 11110 5 x 2,5 10,1 120,0 221,0 14
11055 5G1 7,3 48,0 104,0 18 11111 6 G 2,5 11,2 144,0 293,0 14
11056 5x1 7,3 48,0 104,0 18 11112 7 G 2,5 11,2 168,0 306,0 14

Dimensions and specifications may be changed without prior notice. (RA01)

42
Flexible Control Cables / PVC Control Cables

JB-750 flexible, colour coded, 750 V, meter marking


A

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-11 / DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-11 and IEC 60227-5 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -15C to +80C compound type TI2 to cadmium-free and contain no silicone
fixed installation -40C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 and free from substances harmful to
Nominal voltage Core identification to JB/OB colour code the wetting properties of lacquers
U0/U 450/750 V GN-YE conductor, 3 cores and above Tests
fixed installation, under protection in the outer layer PVC self-extinguishing and flame retardant
U0/U 600/1000 V Cores stranded in layers with acc. to DIN VDE 0482-332-1-2,
Test voltage 4000 V optimal lay-length DIN EN 60332-1-2, IEC 60332-1 (equivalent
Breakdown voltage min. 8000 V Outer sheath of special PVC DIN VDE 0472 part 804 test method B)
Insulation resistance compound type TM2 to
min. 20 MOhm x km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 Note
Minimum bending radius Sheath colour grey (RAL 7001) G = with green-yellow conductor
flexing 7,5x cable with meter marking x = without green-yellow conductor (OB).
fixed installation 4x cable Cleanroom qualification tested with analog
Radiation resistance type. Please note "cleanroom qualified"
up to 80x106 cJ/kg (up to 80 Mrad) when ordering.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
Y-CY-JB, confer page 62

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, as measuring and control cables in tool machinery, conveyor belts, production lines, as well as in machinery
production, in air-conditioning and steel production plants. The earth core is located immediately below the outer sheath. JB cables are suitable for
use in all electrical equipment either in dry or damp areas. They should not, however, be installed in the open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11161 2 x 2,5 8,6 48,0 130,0 14 11155 3 G 25 24,4 720,0 1388,0 4
11162 3 G 2,5 9,3 72,0 164,0 14 11136 4 G 25 27,1 960,0 1581,0 4
11163 3 x 2,5 9,3 72,0 164,0 14 11137 5 G 25 30,1 1200,0 1997,0 4
11164 4 G 2,5 10,2 96,0 200,0 14 11156 3 G 35 27,0 1008,0 1767,0 2
11165 4 x 2,5 10,2 96,0 200,0 14 11138 4 G 35 29,9 1344,0 2105,0 2
11166 5 G 2,5 11,4 120,0 247,0 14 11139 5 G 35 33,4 1680,0 2636,0 2
11167 5 x 2,5 11,4 120,0 247,0 14 11157 3 G 50 31,9 1440,0 2556,0 1
11168 6 G 2,5 12,6 144,0 301,0 14 11140 4 G 50 35,5 1920,0 2940,0 1
11169 7 G 2,5 12,6 168,0 321,0 14 11145 5 G 50 39,2 2400,0 3936,0 1
11121 2x4 10,6 76,8 195,0 12 11158 3 G 70 36,4 2016,0 3182,0 2/0
11144 3G4 11,3 115,0 235,0 12 11141 4 G 70 40,2 2688,0 4090,0 2/0
11122 4G4 12,5 154,0 295,0 12 11146 5 G 70 44,9 3360,0 5443,0 2/0
11123 5G4 13,9 192,0 361,0 12 11159 3 G 95 41,5 2736,0 4676,0 3/0
11124 7G4 15,4 269,0 498,0 12 11142 4 G 95 46,0 3648,0 5540,0 3/0
11125 11 G 4 20,2 422,0 767,0 12 11147 5 G 95 51,3 4560,0 6931,0 3/0
11126 3G6 12,8 173,0 355,0 10 11160 3 G 120 45,9 3456,0 5630,0 4/0
11127 4G6 14,2 230,0 424,0 10 11143 4 G 120 51,3 4608,0 7000,0 4/0
11128 5G6 15,8 288,0 525,0 10 11148 4 G 150 58,7 5760,0 8340,0 300 kcmil
11129 7G6 17,4 403,0 625,0 10 11149 4 G 185 64,3 7104,0 9904,0 350 kcmil
11153 3 G 10 16,2 290,0 611,0 8
11130 4 G 10 18,1 384,0 701,0 8
11131 5 G 10 20,1 480,0 858,0 8
11132 7 G 10 22,2 672,0 1106,0 8
11154 3 G 16 19,8 461,0 912,0 6
11133 4 G 16 22,0 614,0 1035,0 6
11134 5 G 16 24,4 768,0 1259,0 6
11135 7 G 16 27,0 1075,0 1780,0 6

Dimensions and specifications may be changed without prior notice. (RA01)

43
Flexible Control Cables / PVC Control Cables

JB-750 yellow 750 V , connection cable fr warning indication, flexible, colour


coded, meter marking

Technical data Cable structure Properties


Special-PVC connection cable Bare copper-conductor, to Extensively oil resistant,
for warning indication adapted DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
to DIN VDE 0285-525-2-11 / BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
DIN EN 50525-2-11 Core insulation of special PVC The materials used in manufacture are
Temperature range compound type TI2 to cadmium-free and contain no silicone
flexing -15C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 and free from substances harmful to
fixed installation -40C to +80C Core identification to DIN VDE 0293 the wetting properties of lacquers
Nominal voltage U0/U 450/750 V GN-YE conductor Tests
Test voltage 4000 V Cores stranded in layers with PVC self-extinguishing and flame retardant
Breakdown voltage min. 8000 V optimal lay-length acc. to DIN VDE 0482-332-1-2,
Insulation resistance Outer sheath of special PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
min. 20 MOhm x km compound type TM2 to DIN VDE 0472 part 804 test method B)
Minimum bending radius DIN VDE 0207-363-4-1/DIN EN 50363-4-1
flexing 7,5x cable Sheath colour yellow (RAL 1016) Note
fixed installation 4x cable with meter marking G = with green-yellow conductor
Radiation resistance AWG sizes are approximate equivalent
up to 80x106 cJ/kg (up to 80 Mrad) values. The actual cross-section is in mm.

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, as connection cable with yellow outer sheath as a special warning indication. Recommendation in
accordance to EN 60204 part 1 and DIN VDE 0113 part 1.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10334 3 G 1,5 7,8 43,0 100,0 16 10337 3 G 2,5 9,3 72,0 154,0 14
10335 4 G 1,5 8,5 58,0 121,0 16 10338 4 G 2,5 10,2 96,0 208,0 14
10336 5 G 1,5 9,6 72,0 148,0 16 10339 5 G 2,5 11,4 120,0 229,0 14

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

44
Flexible Control Cables / PVC Control Cables

H03VV-F
A

Technical data Cable structure Properties


PVC control cable acc. to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0285-525-2-11 / DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN EN 50525-2-11 and IEC 60227-5 BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
Temperature range Core insulation of PVC the wetting properties of lacquers
flexing -5C to +70C compound type TI2 to Tests
fixed installation -40C to +70C DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
Nominal voltage U0/U 300/300 V Core identification to DIN VDE 0293-308 acc. to DIN VDE 0482-332-1-2,
Test voltage 2000 V - up to 5 cores coloured DIN EN 60332-1-2, IEC 60332-1 (equivalent
Breakdown voltage min. 4000 V - from 6 cores, black with continuous DIN VDE 0472 part 804 test method B)
Insulation resistance white numbering
min. 20 MOhm x km GN-YE conductor, 3 cores and above Note
Minimum bending radius Cores stranded in layers with G = with green-yellow conductor
flexing 7,5x cable optimal lay-length x = without green-yellow conductor
Radiation resistance Outer sheath of PVC 5 core and above in adaption (H).
up to 80x106 cJ/kg (up to 80 Mrad) compound type TM2 to The above list contains a selection of
DIN VDE 0207-363-4-1/DIN EN 50363-4-1 the types we carry es stock. Other sizes
Sheath colour black, white or available on request.
in accordance to the customer AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cable types are especially suited to use on small appliances with low mechanical stress and for connection for light household appliances, e. g.
kitchen utensils, desk lamps, floor lamps, vacuum cleaners, office machines, radios, etc. , as far as this cable is admitted to the relevant specifications
of the equipment.
These cables are not permitted to use with cooking or heating apparatus.
Cables with cross-section 0,75 mm are not suitable for outdoor use or use of industrial or farmer machineries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Sheath Outer Cop. Weight AWG-No. Part no. No.cores x Sheath Outer Cop. Weight AWG-No.
cross-sec. colour min. - max. weight approx. cross-sec. colour min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
29736 2 x 0,5 black 4,6 - 5,9 9,6 40,0 20 29406 4 G 0,75 black 5,7 - 7,3 29,0 72,0 19
29737 2 x 0,5 white 4,6 - 5,9 9,6 40,0 20 29407 4 G 0,75 white 5,7 - 7,3 29,0 72,0 19
29738 2 x 0,5 other colours 4,6 - 5,9 9,6 40,0 20 29408 4 G 0,75 other colours 5,7 - 7,3 29,0 72,0 19
29739 3 G 0,5 black 4,9 - 6,3 14,4 49,0 20 29409 5 G 0,75 black 6,5 - 8,2 36,0 87,0 19
29740 3 G 0,5 white 4,9 - 6,3 14,4 49,0 20 29410 5 G 0,75 white 6,5 - 8,2 36,0 87,0 19
29741 3 G 0,5 other colours 4,9 - 6,3 14,4 49,0 20 29411 5 G 0,75 other colours 6,5 - 8,2 36,0 87,0 19
29742 4 G 0,5 black 5,4 - 6,9 19,2 61,0 20 29412 6 G 0,75 black 7,1 - 9,0 43,0 98,0 19
29743 4 G 0,5 white 5,4 - 6,9 19,2 61,0 20 29413 6 G 0,75 white 7,1 - 9,0 43,0 98,0 19
29744 4 G 0,5 other colours 5,4 - 6,9 19,2 61,0 20 29414 6 G 0,75 other colours 7,1 - 9,0 43,0 98,0 19
29400 2 x 0,75 black 4,9 - 6,3 14,4 49,0 19 29415 7 G 0,75 black 7,1 - 9,0 50,0 108,0 19
29401 2 x 0,75 white 4,9 - 6,3 14,4 49,0 19 29416 7 G 0,75 white 7,1 - 9,0 50,0 108,0 19
29402 2 x 0,75 other colours 4,9 - 6,3 14,4 49,0 19 29417 7 G 0,75 other colours 7,1 - 9,0 50,0 108,0 19
29403 3 G 0,75 black 5,2 - 6,7 21,6 59,0 19
29404 3 G 0,75 white 5,2 - 6,7 21,6 59,0 19
29405 3 G 0,75 other colours 5,2 - 6,7 21,6 59,0 19

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

45
Flexible Control Cables / PVC Control Cables

H05VV-F

Technical data Cable structure Properties


PVC control cable acc. to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0285-525-2-11 / DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN EN 50525-2-11 and IEC 60227-5 BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
Temperature range Core insulation of PVC the wetting properties of lacquers
flexing -5C to +70C compound type TI2 to Tests
fixed installation -40C to +70C DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
Nominal voltage U0/U 300/500 V Core identification to DIN VDE 0293-308 acc. to DIN VDE 0482-332-1-2,
Max. permissible operating voltage in - up to 5 cores coloured DIN EN 60332-1-2, IEC 60332-1 (equivalent
three-phase and one-phase a.c. system - from 6 cores, black with continuous DIN VDE 0472 part 804 test method B)
U0/U 318/550 V white numbering
in direct current system GN-YE conductor, 3 cores and above Note
U0/U 413/825 V Cores stranded in layers with G = with green-yellow conductor
Test voltage 2000 V optimal lay-length x = without green-yellow conductor
Breakdown voltage min. 4000 V Outer sheath of PVC These types are also available with
Insulation resistance compound type TM2 to UL-approbation.
min. 20 MOhm x km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 The above list contains a selection of the
Minimum bending radius Sheath colour black or white types we carry as stock.
flexing 7,5x cable Other sizes available on request.
Radiation resistance Cables with 7 cores and cross-sec. 6 mm
up to 80x106 cJ/kg (up to 80 Mrad) are only available in adaption
designation 05VV-F.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables are especially suited to use for the appliance with medium mechanical stress in households, kitchens and offices, also for household
appliances in damp and wet areas, e. g. refrigerators, washing machines, spin-driver etc. As far as this cable is admitted to the relevant specifications
of the equipment.
These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact with hot parts of
the apparatus and no other influences of heat.
The cables are suitable for fixed installation in furnitures, partition walls, decoration covering and in hollow spaces of prefabricated building parts.
They are not qualified for use in outdoors or for use with industrial and farmer machineries, exceptionally in tailoring, etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Sheath Outer Cop. Weight AWG-No. Part no. No.cores x Sheath Outer Cop. Weight AWG-No.
cross-sec. colour min. - max. weight approx. cross-sec. colour min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
29450 2 x 0,75 black 5,7 - 7,2 14,4 50,0 19 29474 7 G 1,5 black 11,3 - 14,0 101,0 183,0 16
29451 2 x 0,75 white 5,7 - 7,2 14,4 50,0 19 29475 7 G 1,5 white 11,3 - 14,0 101,0 183,0 16
29452 3 G 0,75 black 6,0 - 7,6 21,6 60,0 19 29478 3 G 2,5 black 9,2 - 11,4 72,0 152,0 14
29453 3 G 0,75 white 6,0 - 7,6 21,6 60,0 19 29479 3 G 2,5 white 9,2 - 11,4 72,0 152,0 14
29454 4 G 0,75 black 6,6 - 8,3 29,0 73,0 19 29480 4 G 2,5 black 10,1 - 12,5 96,0 192,0 14
29455 4 G 0,75 white 6,6 - 8,3 29,0 73,0 19 29481 4 G 2,5 white 10,1 - 12,5 96,0 192,0 14
29456 5 G 0,75 black 7,4 - 9,3 36,0 88,0 19 29482 5 G 2,5 black 11,2 - 13,9 120,0 243,0 14
29457 5 G 0,75 white 7,4 - 9,3 36,0 88,0 19 29483 5 G 2,5 white 11,2 - 13,9 120,0 243,0 14
29458 2x1 black 5,9 - 7,5 19,0 57,0 18 29486 7 G 2,5 black 13,8 - 17,1 168,0 316,0 14
29459 2x1 white 5,9 - 7,5 19,0 57,0 18 29487 7 G 2,5 white 13,8 - 17,1 168,0 316,0 14
29460 3G1 black 6,3 - 8,0 29,0 73,0 18 29825 3G4 black 10,5 - 13,1 115,0 235,0 12
29461 3G1 white 6,3 - 8,0 29,0 73,0 18 29826 3G4 white 10,5 - 13,1 115,0 235,0 12
29462 4G1 black 7,1 - 9,0 38,0 85,0 18 29488 4G4 black 11,5 - 14,3 154,0 300,0 12
29463 4G1 white 7,1 - 9,0 38,0 85,0 18 29489 4G4 white 11,5 - 14,3 154,0 300,0 12
29464 5G1 black 7,8 - 9,8 48,0 105,0 18 29490 5G4 black 13,0 - 16,1 192,0 361,0 12
29465 5G1 white 7,8 - 9,8 48,0 105,0 18 29491 5G4 white 13,0 - 16,1 192,0 361,0 12
29466 7G1 black 9,7 - 12,1 67,0 131,0 18 29492 4G6 black 12,9 - 15,9 230,0 490,0 10
29467 7G1 white 9,7 - 12,1 67,0 131,0 18 29493 4G6 white 12,9 - 15,9 230,0 490,0 10
29484 2 x 1,5 black 6,8 - 8,6 29,0 82,0 16
29485 2 x 1,5 white 6,8 - 8,6 29,0 82,0 16
29468 3 G 1,5 black 7,4 - 9,4 43,0 95,0 16
29469 3 G 1,5 white 7,4 - 9,4 43,0 95,0 16
29470 4 G 1,5 black 8,4 - 10,5 58,0 117,0 16
29471 4 G 1,5 white 8,4 - 10,5 58,0 117,0 16
29472 5 G 1,5 black 9,3 - 11,6 72,0 144,0 16
29473 5 G 1,5 white 9,3 - 11,6 72,0 144,0 16

Dimensions and specifications may be changed without prior notice. (RA01)

46
Flexible Control Cables / PVC Control Cables

H05VV-F
A

Technical data Cable structure Properties


PVC-control cables to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0285-525-2-11 / DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN EN 50525-2-11 and IEC 60227-5 BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
Temperature range Core insulation of PVC the wetting properties of lacquers
flexing -5C to +70C compound type TI2 to Tests
fixed installation -40C to +70C DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
Nominal voltage U0/U 300/500 V Core identification to DIN VDE 0293-308 acc. to DIN VDE 0482-332-1-2,
Max. permissible operating voltage in - up to 5 cores coloured DIN EN 60332-1-2, IEC 60332-1 (equivalent
three-phase and one-phase a.c. system - from 6 cores, black with continuous DIN VDE 0472 part 804 test method B)
U0/U 318/550 V white numbering
in direct current system GN-YE conductor, 3 cores and above Note
U0/U 413/825 V Cores stranded in layers with G = with green-yellow conductor
Test voltage 2000 V optimal lay-length x = without green-yellow conductor
Breakdown voltage min. 4000 V Outer sheath of PVC Please add the individual part no.
Insulation resistance compound type TM2 to for order with the identification
min. 20 MOhm x km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 colour code:
Minimum bending radius Sheath colour by request 0 = approx.RAL 5015 blue
flexing 7,5x cable 1 = approx.RAL 6018 green
Radiation resistance 2 = approx.RAL 8003 brown
up to 80x106 cJ/kg (up to 80 Mrad) 3 = approx.RAL 1021 yellow
4 = approx.RAL 3000 red
5 = approx.RAL 2003 orange
6 = approx.RAL 4005 violet
7 = approx.RAL 7001/7032 grey
8 = gold
9 = dusty gold
Further colours on request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cable are especially suited to use for the appliance with medium mechanical stress in households, kitchens and offices, also for household
appliances in damp and wet areas, e. g. refrigerators, washing machines, spin-driver etc. As far as this cable is admitted to the relevant specifications
of the equipment. These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact
with hot parts of the apparatus and no other influences of heat. The cables are suitable for fixed installation in furnitures, partition walls, decoration
covering and in hollow spaces of prefabricated building parts.
They are not qualified for use in outdoors or for use with industrial and farmer machineries, exceptionally in tailoring, etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
3011x 2 x 0,75 5,7 - 7,2 14,4 50,0 19 3020x 2 x 1,5 6,8 - 8,6 29,0 82,0 16
3012x 3 G 0,75 6,0 - 7,6 21,6 60,0 19 3021x 3 G 1,5 7,4 - 9,4 43,0 95,0 16
3013x 4 G 0,75 6,6 - 8,3 29,0 73,0 19 3022x 4 G 1,5 8,4 - 10,5 58,0 117,0 16
3014x 5 G 0,75 7,4 - 9,3 36,0 88,0 19 3023x 5 G 1,5 9,3 - 11,6 72,0 144,0 16
3015x 2x1 5,9 - 7,5 19,0 57,0 18 3024x 3 G 2,5 9,2 - 11,4 72,0 152,0 14
3016x 3G1 6,3 - 8,0 29,0 73,0 18 3025x 4 G 2,5 10,1 - 12,5 96,0 192,0 14
3017x 4G1 7,1 - 9,0 38,0 85,0 18 3026x 5 G 2,5 11,2 - 13,9 120,0 243,0 14
3018x 5G1 7,8 - 9,8 48,0 105,0 18

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

47
Flexible Control Cables / PVC Control Cables

F-CY-OZ (LiY-CY) flexible, Cu-screened, EMC-preferred type,


meter marking

Technical data Cable structure Properties


Special-PVC data cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -10C to +80C compound type Z 7225 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage black cores with continuous white the wetting properties of lacquers
for 1-core (LiYDY) 1200 V numbering Tests
from 2-cores U0/U 300/500 V Cores stranded in layers with PVC self-extinguishing and flame retardant
Test voltage core/core 4000 V optimal lay-length acc. to DIN VDE 0482-332-1-2,
core/screen 2000 V Core wrapping with foil DIN EN 60332-1-2, IEC 60332-1 (equivalent
Breakdown voltage min. 8000 V - for 1-core (LiYDY) copper screen of DIN VDE 0472 part 804 test method B)
Insulation resistance helically wound, approx. 85% coverage
min. 20 MOhm x km - from 2-cores tinned copper braided Note
Mutual capacitance screen, approx. 85% coverage x = without green-yellow conductor (OZ)
acc. to different cross-sections Outer sheath of special PVC Designation: LiYDY for 1-core cable.
core/core approx. 150 nF/km compound type TM2 to Cleanroom qualification tested with analog
core/screen approx. 270 nF/km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 type. Please note "cleanroom qualified"
Coupling resistance Sheath colour grey (RAL 7001) when ordering.
max. 250 Ohm/km with meter marking For more information, see introduction
Minimum bending radius AWG sizes are approximate equivalent
flexing 10x cable values. The actual cross-section is in mm.
fixed installation 5x cable unscreened analogue type:
Radiation resistance JZ-500, confer page 30
up to 80x106 cJ/kg (up to 80 Mrad)

Application
For flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not in open air, as data cable in the
control and regulation technology, tool and machinery, in computer systems, as well as signal line in the electronic. A stabilizing foil separator between
wire bound and braid reduces the outer diameter essentially and allows smaller bending radius, lower weight etc. The disturbance free transmission
of signals and impulses is ensured due to the high degree of screening. This is an ideal disturbance-free control cable for the above applications.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16531 1 x 0,5 3,7 15,0 41,0 20 16544 20 x 0,5 12,3 172,0 240,0 20
16532 2 x 0,5 5,7 35,0 45,0 20 16545 21 x 0,5 12,3 188,0 250,0 20
16533 3 x 0,5 5,9 42,0 55,0 20 16546 24 x 0,5 13,6 235,0 300,0 20
16534 4 x 0,5 6,4 47,0 61,0 20 16547 25 x 0,5 13,7 240,0 314,0 20
16535 5 x 0,5 6,9 56,0 74,0 20 16548 30 x 0,5 14,4 295,0 360,0 20
16536 6 x 0,5 7,6 67,0 89,0 20 16549 32 x 0,5 14,9 301,0 425,0 20
16537 7 x 0,5 7,6 69,0 98,0 20 16550 34 x 0,5 15,5 312,0 433,0 20
16538 8 x 0,5 8,1 80,0 117,0 20 16551 36 x 0,5 15,5 318,0 446,0 20
16539 10 x 0,5 9,6 94,0 135,0 20 16552 40 x 0,5 16,5 343,0 475,0 20
16540 12 x 0,5 9,7 108,0 157,0 20 16553 50 x 0,5 18,5 406,0 573,0 20
16541 14 x 0,5 10,2 116,0 190,0 20 16554 61 x 0,5 19,7 508,0 653,0 20
16542 16 x 0,5 11,0 129,0 210,0 20 16555 80 x 0,5 22,6 680,0 784,0 20
16543 18 x 0,5 11,5 145,0 217,0 20 16556 100 x 0,5 24,9 804,0 995,0 20

Continuation

48
Flexible Control Cables / PVC Control Cables

F-CY-OZ (LiY-CY) flexible, Cu-screened, EMC-preferred type,


meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16557 1 x 0,75 4,0 19,0 44,0 19 16074 1 x 1,5 4,6 27,0 70,0 16
16558 2 x 0,75 6,1 40,0 59,0 19 16075 2 x 1,5 7,0 63,0 88,0 16
16559 3 x 0,75 6,3 52,0 66,0 19 16076 3 x 1,5 7,4 80,0 100,0 16
16560 4 x 0,75 6,8 60,0 77,0 19 16077 4 x 1,5 8,1 97,0 126,0 16
16561 5 x 0,75 7,4 71,0 93,0 19 16078 5 x 1,5 9,0 119,0 160,0 16
16562 6 x 0,75 8,2 80,0 113,0 19 16079 7 x 1,5 9,8 147,0 208,0 16
16563 7 x 0,75 8,2 91,0 130,0 19 16080 8 x 1,5 10,8 170,0 244,0 16
16564 8 x 0,75 9,0 110,0 145,0 19 16081 10 x 1,5 12,6 193,0 316,0 16
16565 10 x 0,75 10,3 137,0 180,0 19 16082 12 x 1,5 12,8 267,0 338,0 16
16566 12 x 0,75 10,5 142,0 202,0 19 16083 14 x 1,5 13,5 283,0 383,0 16
16567 14 x 0,75 11,3 180,0 225,0 19 16084 16 x 1,5 14,6 315,0 424,0 16
16568 16 x 0,75 11,9 200,0 275,0 19 16085 18 x 1,5 15,6 374,0 479,0 16
16569 18 x 0,75 12,7 212,0 292,0 19 16086 20 x 1,5 16,6 396,0 545,0 16
16570 19 x 0,75 12,7 230,0 308,0 19 16087 24 x 1,5 18,1 458,0 690,0 16
16571 20 x 0,75 13,6 238,0 320,0 19 16088 25 x 1,5 18,4 526,0 705,0 16
16572 21 x 0,75 13,6 246,0 378,0 19 16089 28 x 1,5 19,3 541,0 810,0 16
16573 24 x 0,75 14,9 270,0 435,0 19 16090 30 x 1,5 19,6 555,0 830,0 16
16574 25 x 0,75 15,0 281,0 415,0 19 16091 35 x 1,5 21,2 645,0 890,0 16
16575 27 x 0,75 15,1 304,0 435,0 19 16092 40 x 1,5 22,0 725,0 1060,0 16
16576 30 x 0,75 16,0 320,0 450,0 19 16093 50 x 1,5 25,0 885,0 1440,0 16
16577 32 x 0,75 16,7 342,0 484,0 19 16094 61 x 1,5 26,8 1100,0 1700,0 16
16578 34 x 0,75 17,2 345,0 502,0 19 16095 80 x 1,5 30,8 1324,0 2000,0 16
16579 36 x 0,75 17,4 350,0 535,0 19 16096 100 x 1,5 34,1 1641,0 2500,0 16
16580 37 x 0,75 17,4 361,0 592,0 19 16097 1 x 2,5 5,4 39,0 50,0 14
16581 40 x 0,75 18,1 369,0 610,0 19 16098 2 x 2,5 8,4 96,0 130,0 14
16582 50 x 0,75 20,3 461,0 777,0 19 16099 3 x 2,5 8,8 144,0 167,0 14
16583 61 x 0,75 22,0 540,0 900,0 19 16100 4 x 2,5 9,8 148,0 195,0 14
16584 80 x 0,75 25,3 711,0 1210,0 19 16101 5 x 2,5 10,8 181,0 223,0 14
16585 100 x 0,75 28,0 900,0 1445,0 19 16102 7 x 2,5 11,9 255,0 344,0 14
16050 1x1 4,1 21,0 47,0 18 16103 12 x 2,5 15,8 441,0 522,0 14
16051 2x1 6,4 50,0 65,0 18 16104 2x4 10,0 120,0 185,0 12
16052 3x1 6,7 60,0 81,0 18 16105 3x4 10,6 174,0 240,0 12
16053 4x1 7,2 71,0 98,0 18 16106 4x4 11,6 230,0 310,0 12
16054 5x1 8,0 88,0 127,0 18 16107 5x4 12,8 273,0 400,0 12
16055 6x1 8,7 97,0 144,0 18 16108 7x4 14,2 316,0 500,0 12
16056 7x1 8,7 111,0 158,0 18 16109 2x6 11,7 173,0 268,0 10
16057 8x1 9,6 127,0 197,0 18 16110 3x6 12,5 240,0 330,0 10
16058 10 x 1 11,2 150,0 232,0 18 16111 4x6 13,8 305,0 415,0 10
16059 12 x 1 11,4 184,0 260,0 18 16112 5x6 15,4 439,0 509,0 10
16060 14 x 1 12,0 196,0 302,0 18 16113 7x6 17,0 505,0 672,0 10
16061 16 x 1 12,8 209,0 345,0 18 16114 2 x 10 14,5 255,0 425,0 8
16062 18 x 1 13,6 260,0 380,0 18 16115 3 x 10 15,6 350,0 500,0 8
16063 20 x 1 14,3 317,0 440,0 18 16116 4 x 10 17,2 535,0 783,0 8
16064 24 x 1 16,0 320,0 495,0 18 16117 5 x 10 19,1 592,0 856,0 8
16065 25 x 1 16,2 349,0 534,0 18 16118 7 x 10 21,2 810,0 1300,0 8
16066 28 x 1 17,0 408,0 595,0 18
16067 30 x 1 17,2 441,0 616,0 18
16068 34 x 1 18,5 486,0 741,0 18
16069 40 x 1 19,4 510,0 835,0 18
16070 50 x 1 22,0 625,0 1025,0 18
16071 61 x 1 23,5 702,0 1200,0 18
16072 80 x 1 26,9 920,0 1440,0 18
16073 100 x 1 30,2 1120,0 1610,0 18

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

49
Flexible Control Cables / PVC Control Cables

F-CY-JZ flexible, Cu-screened, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -10C to +80C compound type Z 7225 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage U0/U 300/500 V black cores with continuous white the wetting properties of lacquers
Test voltage numbering Tests
core/core 4000 V GN-YE conductor, 3 cores and above PVC self-extinguishing and flame retardant
core/screen 2000 V in the outer layer acc. to DIN VDE 0482-332-1-2,
Breakdown voltage min. 8000 V Cores stranded in layers with DIN EN 60332-1-2, IEC 60332-1 (equivalent
Insulation resistance optimal lay-length DIN VDE 0472 part 804 test method B)
min. 20 MOhm x km Foil separator
Mutual capacitance Tinned copper braided screening, Note
acc. to different cross-sections approx. 85% coverage G = with green-yellow conductor
0,5 up to 2,5 mm: Outer sheath of special PVC x = without green-yellow conductor (OZ)
core/core approx. 150 nF/km compound type TM2 to Please note the cleanroom qualification
core/screen approx. 270 nF/km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 when ordering. For more information,
Coupling resistance Sheath colour grey (RAL 7001) see introduction.
max. 250 Ohm/km With meter marking AWG sizes are approximate equivalent
Minimum bending radius values. The actual cross-section is in mm.
flexing 10x cable unscreened analogue type:
fixed installation 5x cable JZ-500, confer page 30
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
For use as a data cable in control circuits, in tool-making and machine industries as well as a signal cable in computer systems and electronics. The
more usual PVC inner sheath has been replaced in these cables by a stabilising foil separator, thus reducing the total diameter of the cables considerably
and thereby reducing the bending radius, total weight etc. The high covering percentage of the copper screening offers interference-free signal transfer
etc. The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above
application.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16320 2 x 0,5 5,7 35,0 45,0 20 16333 21 G 0,5 12,3 188,0 250,0 20
16321 3 G 0,5 5,9 42,0 55,0 20 16334 24 G 0,5 13,6 235,0 300,0 20
16322 4 G 0,5 6,4 47,0 61,0 20 16335 25 G 0,5 13,7 240,0 314,0 20
16323 5 G 0,5 6,9 56,0 74,0 20 16336 30 G 0,5 14,4 295,0 360,0 20
16324 6 G 0,5 7,6 67,0 89,0 20 16337 32 G 0,5 14,9 301,0 425,0 20
16325 7 G 0,5 7,6 69,0 98,0 20 16165 34 G 0,5 15,6 312,0 433,0 20
16326 8 G 0,5 8,1 80,0 117,0 20 16338 36 G 0,5 15,6 318,0 446,0 20
16327 10 G 0,5 9,6 94,0 135,0 20 16339 40 G 0,5 16,4 343,0 475,0 20
16328 12 G 0,5 9,7 108,0 157,0 20 16490 41 G 0,5 16,5 348,0 486,0 20
16329 14 G 0,5 10,2 116,0 190,0 20 16340 50 G 0,5 18,5 406,0 573,0 20
16330 16 G 0,5 11,0 129,0 210,0 20 16341 61 G 0,5 19,7 508,0 653,0 20
16331 18 G 0,5 11,5 145,0 217,0 20 16342 80 G 0,5 22,6 680,0 784,0 20
16332 20 G 0,5 12,3 172,0 240,0 20 16343 100 G 0,5 24,9 804,0 995,0 20

Continuation

50
Flexible Control Cables / PVC Control Cables

F-CY-JZ flexible, Cu-screened, EMC-preferred type, meter marking

Part no. No.cores x


cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No. Part no. No.cores x
cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No.
A
16344 2 x 0,75 6,1 40,0 59,0 19 16393 2 x 1,5 7,0 63,0 88,0 16
16345 3 G 0,75 6,3 52,0 66,0 19 16394 3 G 1,5 7,4 80,0 100,0 16
16346 4 G 0,75 6,8 60,0 77,0 19 16395 4 G 1,5 8,1 97,0 126,0 16
16347 5 G 0,75 7,4 71,0 93,0 19 16396 5 G 1,5 9,0 119,0 160,0 16
16348 6 G 0,75 8,2 80,0 113,0 19 16397 7 G 1,5 9,8 147,0 208,0 16
16349 7 G 0,75 8,2 91,0 130,0 19 16398 8 G 1,5 10,8 170,0 244,0 16
16350 8 G 0,75 9,0 110,0 145,0 19 16399 10 G 1,5 12,6 193,0 315,0 16
16351 10 G 0,75 10,3 137,0 180,0 19 16400 12 G 1,5 12,8 267,0 338,0 16
16353 12 G 0,75 10,5 142,0 202,0 19 16401 14 G 1,5 13,5 283,0 383,0 16
16354 14 G 0,75 11,3 180,0 225,0 19 16402 16 G 1,5 14,6 315,0 424,0 16
16355 16 G 0,75 11,9 200,0 275,0 19 16403 18 G 1,5 15,6 374,0 479,0 16
16356 18 G 0,75 12,7 212,0 292,0 19 16449 19 G 1,5 15,6 386,0 508,0 16
16447 19 G 0,75 12,7 230,0 308,0 19 16404 20 G 1,5 16,6 396,0 545,0 16
16357 20 G 0,75 13,6 238,0 320,0 19 16405 21 G 1,5 16,6 425,0 560,0 16
16358 21 G 0,75 13,6 246,0 378,0 19 16406 24 G 1,5 18,1 458,0 690,0 16
16359 24 G 0,75 14,9 270,0 435,0 19 16407 25 G 1,5 18,4 526,0 705,0 16
16360 25 G 0,75 15,0 281,0 415,0 19 16450 27 G 1,5 18,5 531,0 774,0 16
16361 27 G 0,75 15,0 304,0 435,0 19 16408 28 G 1,5 19,6 541,0 810,0 16
16362 30 G 0,75 16,0 320,0 450,0 19 16409 30 G 1,5 19,6 555,0 830,0 16
16363 32 G 0,75 16,7 342,0 484,0 19 16410 35 G 1,5 21,4 645,0 890,0 16
16166 34 G 0,75 17,2 345,0 502,0 19 16451 37 G 1,5 21,4 674,0 945,0 16
16364 36 G 0,75 17,4 350,0 535,0 19 16411 40 G 1,5 22,0 725,0 1060,0 16
16448 37 G 0,75 17,4 361,0 592,0 19 16493 41 G 1,5 22,2 801,0 1071,0 16
16365 40 G 0,75 18,1 369,0 610,0 19 16412 50 G 1,5 25,0 885,0 1290,0 16
16491 41 G 0,75 18,2 400,0 622,0 19 16413 61 G 1,5 26,8 1100,0 1705,0 16
16366 50 G 0,75 20,3 461,0 777,0 19 16414 80 G 1,5 30,8 1324,0 2010,0 16
16367 61 G 0,75 22,0 540,0 900,0 19 16415 100 G 1,5 34,1 1641,0 2505,0 16
16368 80 G 0,75 25,3 711,0 1210,0 19 16416 2 x 2,5 8,4 96,0 130,0 14
16369 100 G 0,75 28,0 900,0 1445,0 19 16417 3 G 2,5 8,8 144,0 167,0 14
16370 2x1 6,4 50,0 65,0 18 16418 4 G 2,5 9,8 148,0 195,0 14
16371 3G1 6,7 60,0 80,0 18 16419 5 G 2,5 10,8 181,0 223,0 14
16372 4G1 7,2 71,0 98,0 18 16420 7 G 2,5 11,9 255,0 344,0 14
16373 5G1 8,0 88,0 127,0 18 16421 10 G 2,5 15,5 340,0 460,0 14
16374 6G1 8,7 97,0 144,0 18 16438 12 G 2,5 15,8 441,0 570,0 14
16375 7G1 8,7 111,0 158,0 18 16452 18 G 2,5 19,0 570,0 681,0 14
16376 8G1 9,6 127,0 197,0 18 16422 2x4 10,0 120,0 185,0 12
16377 10 G 1 11,2 150,0 232,0 18 16423 3G4 10,6 174,0 240,0 12
16378 12 G 1 11,4 184,0 260,0 18 16424 4G4 11,6 230,0 310,0 12
16379 14 G 1 12,0 196,0 302,0 18 16425 5G4 12,8 273,0 385,0 12
16380 16 G 1 12,8 209,0 346,0 18 16426 7G4 14,2 316,0 500,0 12
16381 18 G 1 13,6 260,0 380,0 18 16427 2x6 11,7 173,0 268,0 10
16352 19 G 1 13,6 280,0 412,0 18 16428 3G6 12,5 240,0 330,0 10
16382 20 G 1 14,3 317,0 440,0 18 16429 4G6 13,8 305,0 415,0 10
16383 24 G 1 16,0 320,0 493,0 18 16430 5G6 15,4 439,0 509,0 10
16384 25 G 1 16,2 349,0 534,0 18 16431 7G6 17,0 505,0 672,0 10
16439 27 G 1 16,4 400,0 562,0 18 16432 2 x 10 14,5 255,0 425,0 8
16385 28 G 1 17,0 408,0 595,0 18 16433 3 G 10 15,6 350,0 500,0 8
16386 30 G 1 17,2 441,0 616,0 18 16434 4 G 10 17,2 535,0 783,0 8
16387 34 G 1 18,5 486,0 741,0 18 16435 5 G 10 19,1 592,0 856,0 8
16446 37 G 1 18,6 519,0 790,0 18 16436 7 G 10 21,2 810,0 1305,0 8
16388 40 G 1 19,4 510,0 835,0 18 16440 4 G 16 20,3 740,0 880,0 6
16492 41 G 1 19,5 531,0 843,0 18 16437 5 G 16 22,2 895,0 1295,0 6
16389 50 G 1 22,0 625,0 1025,0 18 16441 4 G 25 24,7 1140,0 1570,0 4
16390 61 G 1 23,5 702,0 1205,0 18 16442 5 G 25 27,4 1380,0 1965,0 4
16391 80 G 1 26,9 920,0 1445,0 18 16443 4 G 35 28,4 1576,0 2070,0 2
16392 100 G 1 30,2 1120,0 1613,0 18 16444 5 G 35 31,6 1930,0 2690,0 2
16445 4 G 50 34,2 2155,0 3015,0 1

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

51
Flexible Control Cables / PVC Control Cables

JZ-500-C black EMC-preferred type, Cu-screened. flexible, meter marking

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -10C to +80C compound type Z 7225 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage U0/U 300/500 V black cores with continuous white the wetting properties of lacquers
Test voltage numbering UV- resistant
core/core 4000 V GN-YE conductor, 3 cores and above Tests
core/screen 2000 V in the outer layer PVC self-extinguishing and flame retardant
Breakdown voltage min. 8000 V Cores stranded in layers with acc. to DIN VDE 0482-332-1-2,
Insulation resistance optimal lay-length DIN EN 60332-1-2, IEC 60332-1 (equivalent
min. 20 MOhm x km Foil separator DIN VDE 0472 part 804 test method B)
Coupling resistance Tinned copper braided screen,
max. 250 Ohm/km approx. 85% coverage Note
Minimum bending radius Outer sheath of special PVC G = with green-yellow conductor
flexing 10x cable compound type TM2 to x = without green-yellow conductor (OZ)
fixed installation 5x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1 AWG sizes are approximate equivalent
Radiation resistance Sheath colour black (RAL 9005) values. The actual cross-section is in mm.
up to 80x106 cJ/kg (up to 80 Mrad) with meter marking unscreened analogue type
JZ-500 black, confer page 32

Application
For medium mechanical stress for flexible use with free movement without tensile stress or forced movements in dry, damp, wet rooms and in open
air. Must not be laid directly in soil or water. When screened for measurement, control and control line etc. in mechanical and plant engineering,
machine tools, production lines and conveyor belts.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10934 2 x 0,5 6,1 35,0 45,0 20 11499 12 x 1 12,4 184,0 260,0 18
10935 3 G 0,5 6,4 42,0 55,0 20 10956 18 G 1 14,7 260,0 380,0 18
11479 3 x 0,5 6,4 42,0 55,0 20 10957 25 G 1 17,5 349,0 534,0 18
10936 4 G 0,5 6,8 47,0 61,0 20 10958 2 x 1,5 7,8 63,0 88,0 16
11480 4 x 0,5 6,8 47,0 61,0 20 10959 3 G 1,5 8,2 80,0 100,0 16
10937 5 G 0,5 7,5 56,0 74,0 20 11500 3 x 1,5 8,2 80,0 100,0 16
11481 5 x 0,5 7,5 56,0 74,0 20 10960 4 G 1,5 8,9 97,0 126,0 16
10938 7 G 0,5 8,1 69,0 98,0 20 11502 4 x 1,5 8,9 97,0 126,0 16
11482 7 x 0,5 8,1 69,0 98,0 20 10961 5 G 1,5 9,8 119,0 160,0 16
10939 12 G 0,5 10,6 108,0 157,0 20 11503 5 x 1,5 9,8 119,0 160,0 16
11483 12 x 0,5 10,6 108,0 157,0 20 10962 7 G 1,5 10,8 147,0 208,0 16
10940 18 G 0,5 12,4 145,0 217,0 20 11520 7 x 1,5 10,8 147,0 208,0 16
10941 25 G 0,5 14,7 240,0 314,0 20 10963 12 G 1,5 14,0 267,0 338,0 16
10942 2 x 0,75 6,7 40,0 59,0 19 11522 12 x 1,5 14,0 267,0 338,0 16
10943 3 G 0,75 7,0 52,0 66,0 19 10964 18 G 1,5 16,8 374,0 479,0 16
11484 3 x 0,75 7,0 52,0 66,0 19 10965 25 G 1,5 19,8 526,0 705,0 16
10944 4 G 0,75 7,7 60,0 77,0 19 10966 2 x 2,5 9,2 96,0 130,0 14
11485 4 x 0,75 7,7 60,0 77,0 19 10967 3 G 2,5 9,8 144,0 167,0 14
10945 5 G 0,75 8,2 71,0 93,0 19 11523 3 x 2,5 9,8 144,0 167,0 14
11486 5 x 0,75 8,2 71,0 93,0 19 10968 4 G 2,5 10,6 148,0 195,0 14
10946 7 G 0,75 9,0 91,0 130,0 19 11524 4 x 2,5 10,6 148,0 195,0 14
11487 7 x 0,75 9,0 91,0 130,0 19 10969 5 G 2,5 11,7 181,0 223,0 14
10947 12 G 0,75 11,6 142,0 202,0 19 11526 5 x 2,5 11,7 181,0 223,0 14
11488 12 x 0,75 11,6 142,0 202,0 19 10970 7 G 2,5 12,8 255,0 344,0 14
10948 18 G 0,75 13,7 212,0 292,0 19 11527 7 x 2,5 12,8 255,0 344,0 14
10949 25 G 0,75 16,4 281,0 415,0 19 10971 12 G 2,5 17,0 441,0 570,0 14
10950 2x1 7,0 50,0 65,0 18 11550 12 x 2,5 17,0 441,0 570,0 14
10951 3G1 7,5 60,0 80,0 18 10972 18 G 2,5 19,8 570,0 681,0 14
11493 3x1 7,5 60,0 80,0 18 10973 4G4 12,4 230,0 310,0 12
10952 4G1 8,0 71,0 98,0 18 10974 5G4 13,7 273,0 385,0 12
11495 4x1 8,0 71,0 98,0 18 10975 4G6 14,7 305,0 415,0 10
10953 5G1 8,8 88,0 127,0 18 10976 5G6 16,2 439,0 509,0 10
11496 5x1 8,8 88,0 127,0 18 10977 4 G 10 18,2 535,0 783,0 8
10954 7G1 9,5 111,0 158,0 18 10978 4 G 16 21,1 740,0 880,0 6
11497 7x1 9,5 111,0 158,0 18 10979 4 G 25 25,8 1140,0 1570,0 4
10955 12 G 1 12,4 184,0 260,0 18 10980 4 G 35 29,7 1576,0 2070,0 2

Dimensions and specifications may be changed without prior notice. (RA01)

52
Flexible Control Cables / PVC Control Cables

Y-CY-JZ flexible, Cu-screened, transparent, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -15C to +80C compound type Z 7225 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage U0/U 300/500 V black cores with continuous white the wetting properties of lacquers
Test voltage 4000 V numbering Tests
Breakdown voltage min. 8000 V GN-YE conductor, 3 cores and above PVC self-extinguishing and flame retardant
Insulation resistance in the outer layer acc. to DIN VDE 0482-332-1-2,
min. 20 MOhm x km Cores stranded in layers with DIN EN 60332-1-2, IEC 60332-1 (equivalent
Mutual capacitance optimal lay-length DIN VDE 0472 part 804 test method B)
acc. to different cross-sections Inner sheath of PVC, grey
0,5 up to 2,5 mm: Tinned copper braided screen, Note
core/core approx. 150 nF/km approx. 85% coverage G = with green-yellow conductor
core/screen approx. 270 nF/km Outer sheath of special PVC x = without green-yellow conductor (OZ)
Coupling resistance Sheath colour transparent AWG sizes are approximate equivalent
max. 250 Ohm/km with meter marking values. The actual cross-section is in mm.
Minimum bending radius unscreened analogue type:
flexing 10x cable JZ-500, confer page 30
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a
high degree of interference protection. The screening density assures disturbancefree transmission of all signals and impulses. The PVC-inner sheaths
of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical view of the tinned copper braid.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16200 2 x 0,5 7,0 41,0 67,0 20 16219 50 G 0,5 20,7 407,0 740,0 20
16201 3 G 0,5 7,3 45,0 83,0 20 16220 61 G 0,5 22,0 520,0 850,0 20
16169 3 x 0,5 7,3 45,0 83,0 20 16221 80 G 0,5 25,0 690,0 1080,0 20
16202 4 G 0,5 7,9 54,0 94,0 20 16222 100 G 0,5 27,4 805,0 1350,0 20
16170 4 x 0,5 7,9 54,0 94,0 20 16223 2 x 0,75 7,7 46,0 87,0 19
16203 5 G 0,5 8,4 66,0 108,0 20 16224 3 G 0,75 8,0 57,0 98,0 19
16171 5 x 0,5 8,4 66,0 108,0 20 16173 3 x 0,75 8,0 57,0 98,0 19
16204 6 G 0,5 9,1 73,0 125,0 20 16225 4 G 0,75 8,5 63,0 113,0 19
16205 7 G 0,5 9,1 79,0 136,0 20 16196 4 x 0,75 8,5 63,0 113,0 19
17172 7 x 0,5 9,1 79,0 136,0 20 16226 5 G 0,75 9,3 76,0 130,0 19
16206 8 G 0,5 9,7 82,0 150,0 20 16174 5 x 0,75 9,3 76,0 130,0 19
16207 10 G 0,5 10,7 107,0 170,0 20 16227 6 G 0,75 9,9 82,0 156,0 19
16208 12 G 0,5 11,5 137,0 195,0 20 16228 7 G 0,75 9,9 100,0 184,0 19
16209 14 G 0,5 12,2 142,0 223,0 20 16175 7 x 0,75 9,9 100,0 184,0 19
16210 16 G 0,5 12,7 147,0 250,0 20 16229 8 G 0,75 10,6 112,0 221,0 19
16211 18 G 0,5 13,5 156,0 277,0 20 16230 10 G 0,75 11,8 140,0 270,0 19
16212 20 G 0,5 14,2 173,0 310,0 20 16231 12 G 0,75 12,7 175,0 292,0 19
16315 21 G 0,5 14,2 189,0 331,0 20 16232 14 G 0,75 13,3 190,0 315,0 19
16213 24 G 0,5 15,5 236,0 390,0 20 16233 16 G 0,75 14,1 204,0 335,0 19
16214 25 G 0,5 15,7 250,0 407,0 20 16234 18 G 0,75 14,9 240,0 358,0 19
16215 30 G 0,5 16,2 297,0 520,0 20 16235 20 G 0,75 15,4 262,0 420,0 19
16216 32 G 0,5 17,0 312,0 550,0 20 16316 21 G 0,75 15,4 274,0 454,0 19
16217 36 G 0,5 17,7 320,0 585,0 20 16236 24 G 0,75 17,3 291,0 480,0 19
16218 40 G 0,5 18,4 345,0 654,0 20 16237 25 G 0,75 17,5 306,0 508,0 19
16453 41 G 0,5 18,9 348,0 671,0 20 16238 27 G 0,75 17,7 326,0 535,0 19
16239 30 G 0,75 18,3 340,0 640,0 19

Continuation

53
Flexible Control Cables / PVC Control Cables

Y-CY-JZ flexible, Cu-screened, transparent, EMC-preferred type, meter marking

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16240 32 G 0,75 18,9 349,0 688,0 19 16282 20 G 1,5 18,5 401,0 690,0 16
16241 36 G 0,75 19,7 358,0 730,0 19 16317 21 G 1,5 18,5 447,0 720,0 16
16242 40 G 0,75 20,4 371,0 950,0 19 16283 24 G 1,5 20,4 487,0 770,0 16
16454 41 G 0,75 21,0 403,0 971,0 19 16284 25 G 1,5 20,8 531,0 805,0 16
16243 50 G 0,75 23,2 470,0 1100,0 19 16285 28 G 1,5 21,4 562,0 900,0 16
16244 61 G 0,75 24,6 550,0 1290,0 19 16286 30 G 1,5 21,6 598,0 950,0 16
16245 80 G 0,75 28,3 715,0 1510,0 19 16287 35 G 1,5 23,2 685,0 1100,0 16
16246 100 G 0,75 31,1 910,0 1640,0 19 16288 40 G 1,5 24,5 759,0 1350,0 16
16248 2x1 8,0 54,0 97,0 18 16456 41 G 1,5 25,0 840,0 1381,0 16
16249 3G1 8,3 64,0 103,0 18 16289 50 G 1,5 27,4 997,0 1675,0 16
16176 3x1 8,3 64,0 103,0 18 16290 61 G 1,5 29,2 1120,0 1800,0 16
16250 4G1 9,0 76,0 146,0 18 16291 80 G 1,5 33,4 1360,0 2300,0 16
16177 4x1 9,0 76,0 146,0 18 16292 100 G 1,5 36,8 1690,0 2600,0 16
16251 5G1 9,7 89,0 169,0 18 16293 2 x 2,5 10,1 110,0 180,0 14
16178 5x1 9,7 89,0 169,0 18 16294 3 G 2,5 10,8 148,0 216,0 14
16252 6G1 10,3 101,0 199,0 18 16295 4 G 2,5 11,5 169,0 267,0 14
16253 7G1 10,3 114,0 219,0 18 16296 5 G 2,5 12,8 220,0 347,0 14
16179 7x1 10,3 114,0 219,0 18 16297 7 G 2,5 14,0 284,0 407,0 14
16254 8G1 11,2 130,0 270,0 18 16298 10 G 2,5 16,8 369,0 660,0 14
16255 10 G 1 12,6 156,0 330,0 18 16318 12 G 2,5 17,9 470,0 722,0 14
16256 12 G 1 13,3 186,0 350,0 18 16299 2x4 11,6 124,0 302,0 12
16257 14 G 1 14,1 198,0 400,0 18 16300 3G4 12,5 178,0 340,0 12
16258 16 G 1 14,8 214,0 422,0 18 16301 4G4 13,7 234,0 410,0 12
16259 18 G 1 15,6 284,0 514,0 18 16302 5G4 14,9 284,0 502,0 12
16260 20 G 1 16,4 325,0 545,0 18 16303 7G4 16,2 321,0 638,0 12
16261 24 G 1 18,2 366,0 640,0 18 16304 2x6 13,7 176,0 350,0 10
16262 25 G 1 18,5 387,0 689,0 18 16305 3G6 14,4 245,0 450,0 10
16263 28 G 1 19,1 421,0 710,0 18 16306 4G6 15,7 316,0 559,0 10
16264 30 G 1 19,2 457,0 762,0 18 16307 5G6 17,3 442,0 702,0 10
16265 34 G 1 20,9 500,0 910,0 18 16308 7G6 19,0 530,0 907,0 10
16266 40 G 1 21,5 536,0 1070,0 18 16309 2 x 10 16,6 260,0 500,0 8
16455 41 G 1 22,2 578,0 1092,0 18 16310 3 G 10 17,6 367,0 750,0 8
16267 50 G 1 24,8 681,0 1315,0 18 16311 4 G 10 19,4 549,0 1020,0 8
16268 61 G 1 26,0 710,0 1370,0 18 16312 5 G 10 21,3 604,0 1115,0 8
16269 80 G 1 30,0 940,0 1610,0 18 16313 7 G 10 23,4 820,0 1500,0 8
16270 100 G 1 33,1 1180,0 1840,0 18 16460 4 G 16 23,4 807,0 1380,0 6
16271 2 x 1,5 8,6 64,0 130,0 16 16314 5 G 16 26,0 940,0 1553,0 6
16272 3 G 1,5 9,2 82,0 152,0 16 16461 4 G 25 28,3 1169,0 1890,0 4
16180 3 x 1,5 9,2 82,0 152,0 16 16462 5 G 25 31,5 1420,0 2270,0 4
16273 4 G 1,5 9,8 99,0 168,0 16 16463 4 G 35 32,9 1680,0 2390,0 2
16181 4 x 1,5 9,8 99,0 168,0 16 16464 5 G 35 36,9 2020,0 2885,0 2
16274 5 G 1,5 10,8 123,0 202,0 16 16465 4 G 50 38,6 2370,0 3315,0 1
16182 5 x 1,5 10,8 123,0 202,0 16 16157 5 G 50 43,5 2880,0 4150,0 1
16275 7 G 1,5 11,7 148,0 304,0 16 16466 4 G 70 46,1 3257,0 4600,0 2/0
16183 7 x 1,5 11,7 148,0 304,0 16 16158 5 G 70 50,5 4032,0 5750,0 2/0
16276 8 G 1,5 12,6 172,0 336,0 16 16467 4 G 95 51,1 4060,0 6060,0 3/0
16277 10 G 1,5 14,2 198,0 420,0 16 16159 5 G 95 56,0 5244,0 7580,0 3/0
16278 12 G 1,5 14,9 274,0 434,0 16 16468 4 G 120 56,5 5231,0 7315,0 4/0
16279 14 G 1,5 15,8 294,0 480,0 16 16160 5 G 120 62,1 6624,0 9150,0 4/0
16280 16 G 1,5 16,7 318,0 525,0 16 16167 4 G 150 64,6 7760,0 9680,0 300 kcmil
16281 18 G 1,5 17,4 386,0 640,0 16 16168 5 G 150 70,6 8496,0 10170,0 300 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

54
Flexible Control Cables / PVC Control Cables

SY-JZ flexible, number coded, with steel wire braiding, meter marking

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -15C to +80C compound type Z 7225 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage U0/U 300/500 V black cores with continuous white the wetting properties of lacquers
Test voltage 4000 V numbering Tests
Breakdown voltage min. 8000 V GN-YE conductor, 3 cores and above PVC self-extinguishing and flame retardant
Insulation resistance in the outer layer acc. to DIN VDE 0482-332-1-2,
min. 20 MOhm x km Cores stranded in layers with DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius optimal lay-length DIN VDE 0472 part 804 test method B)
flexing 20x cable Inner sheath of special PVC
fixed installation 6x cable Galvanized steel wire braid Note
Radiation resistance Outer sheath of special PVC G = with green-yellow conductor
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour transparent x = without green-yellow conductor (OZ)
with meter marking Further dimensions available on request.
These cables con be also delivered with
coloured conductors (SY-JB).
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
when ordering.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
SY-JB, confer page 64

Application
SY-JZ cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The braided screen
offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect against corrosion,
but also notably improves the soldering performance.
The clear transparent outer sheath gives the cable in addition an optical revaluation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12001 2 x 0,5 7,2 9,6 80,0 20 12027 18 G 0,75 15,0 130,0 388,0 19
12002 3 G 0,5 7,5 14,4 92,0 20 12028 21 G 0,75 15,5 151,0 474,0 19
12003 4 G 0,5 8,1 19,2 102,0 20 12029 25 G 0,75 17,5 180,0 503,0 19
12004 5 G 0,5 8,6 24,0 119,0 20 12030 32 G 0,75 18,9 230,0 644,0 19
12005 7 G 0,5 9,3 33,6 157,0 20 12031 34 G 0,75 19,9 245,0 663,0 19
12006 10 G 0,5 10,7 48,0 205,0 20 12032 41 G 0,75 21,2 296,0 741,0 19
12007 12 G 0,5 11,7 58,0 218,0 20 12033 50 G 0,75 23,2 360,0 925,0 19
12008 14 G 0,5 12,3 67,0 242,0 20 12034 61 G 0,75 25,2 439,0 1082,0 19
12009 18 G 0,5 13,4 86,0 340,0 20 12035 2x1 8,2 19,2 112,0 18
12010 21 G 0,5 14,2 101,0 370,0 20 12036 3G1 8,5 28,8 132,0 18
12114 25 G 0,5 15,7 120,0 406,0 20 12037 4G1 9,2 38,4 143,0 18
12012 30 G 0,5 16,2 144,0 439,0 20 12038 5G1 9,9 48,0 166,0 18
12013 35 G 0,5 17,5 168,0 500,0 20 12039 6G1 10,5 58,0 22,0 18
12014 40 G 0,5 18,2 192,0 565,0 20 12040 7G1 10,5 67,0 227,0 18
12015 42 G 0,5 19,0 202,0 593,0 20 12041 8G1 11,4 77,0 277,0 18
12016 50 G 0,5 20,7 240,0 690,0 20 12042 9G1 12,8 86,0 295,0 18
12017 61 G 0,5 22,0 293,0 843,0 20 12043 12 G 1 13,4 115,0 340,0 18
12018 80 G 0,5 25,0 384,0 1050,0 20 12044 14 G 1 14,2 134,0 420,0 18
12011 100 G 0,5 27,4 480,0 1240,0 20 12045 18 G 1 15,7 173,0 500,0 18
12019 2 x 0,75 7,9 14,4 98,0 19 12046 20 G 1 16,4 192,0 532,0 18
12020 3 G 0,75 8,2 21,6 103,0 19 12047 25 G 1 18,4 240,0 664,0 18
12021 4 G 0,75 8,7 28,8 122,0 19 12048 34 G 1 20,8 326,0 845,0 18
12022 5 G 0,75 9,5 36,0 142,0 19 12049 36 G 1 20,9 346,0 857,0 18
12112 6 G 0,75 10,1 43,2 180,0 19 12050 41 G 1 22,2 394,0 993,0 18
12023 7 G 0,75 10,1 50,0 185,0 19 12051 50 G 1 24,4 480,0 1112,0 18
12188 8 G 0,75 10,8 57,6 201,0 19 12052 56 G 1 25,5 538,0 1225,0 18
12024 9 G 0,75 11,8 65,0 249,0 19 12053 61 G 1 26,1 586,0 1306,0 18
12113 10 G 0,75 12,0 72,0 252,0 19 12054 65 G 1 26,9 624,0 1504,0 18
12025 12 G 0,75 12,8 86,0 292,0 19 12055 80 G 1 30,0 768,0 1750,0 18
12026 15 G 0,75 14,2 108,0 335,0 19 12056 100 G 1 33,1 960,0 1950,0 18

Continuation

55
Flexible Control Cables / PVC Control Cables

SY-JZ flexible, number coded, with steel wire braiding, meter marking

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12057 2 x 1,5 8,8 29,0 129,0 16 12115 3G4 12,6 117,0 350,0 12
12058 3 G 1,5 9,4 43,0 149,0 16 12091 4G4 13,7 154,0 428,0 12
12059 4 G 1,5 10,0 58,0 185,0 16 12092 5G4 14,9 192,0 504,0 12
12060 5 G 1,5 10,9 72,0 205,0 16 12093 7G4 16,2 269,0 640,0 12
12109 6 G 1,5 11,8 87,0 255,0 16 12094 11 G 4 21,2 422,0 1204,0 12
12061 7 G 1,5 11,8 101,0 285,0 16 12095 4G6 15,8 230,0 571,0 10
12062 8 G 1,5 12,7 115,0 340,0 16 12096 5G6 17,3 288,0 671,0 10
12063 9 G 1,5 13,9 130,0 347,0 16 12097 7G6 19,0 403,0 845,0 10
12064 10 G 1,5 14,3 144,0 418,0 16 12098 4 G 10 19,4 384,0 943,0 8
12065 11 G 1,5 14,8 158,0 430,0 16 12099 5 G 10 21,3 480,0 1065,0 8
12066 12 G 1,5 15,0 173,0 444,0 16 12100 7 G 10 23,4 672,0 1551,0 8
12067 14 G 1,5 15,8 202,0 533,0 16 12101 4 G 16 23,6 614,0 1360,0 6
12068 18 G 1,5 17,4 259,0 593,0 16 12102 5 G 16 26,4 768,0 1740,0 6
12069 25 G 1,5 20,8 360,0 781,0 16 12103 7 G 16 29,0 1075,0 2166,0 6
12070 32 G 1,5 22,3 461,0 1015,0 16 12104 4 G 25 28,5 960,0 2020,0 4
12071 34 G 1,5 23,2 490,0 1124,0 16 12105 5 G 25 31,7 1200,0 2465,0 4
12072 42 G 1,5 25,2 605,0 1401,0 16 12106 4 G 35 32,9 1344,0 2570,0 2
12073 50 G 1,5 27,6 720,0 1583,0 16 12107 5 G 35 36,9 1680,0 3185,0 2
12074 61 G 1,5 29,4 878,0 1810,0 16 12108 4 G 50 38,8 1920,0 3513,0 1
12075 80 G 1,5 33,8 1152,0 2316,0 16 12116 5 G 50 43,7 2400,0 4248,0 1
12076 100 G 1,5 37,2 1440,0 2900,0 16 12111 4 G 70 46,3 2688,0 4810,0 2/0
12077 2 x 2,5 10,2 48,0 185,0 14 12117 5 G 70 50,5 3360,0 5880,0 2/0
12078 3 G 2,5 10,9 72,0 248,0 14 12110 4 G 95 51,2 3648,0 6360,0 3/0
12079 4 G 2,5 11,6 96,0 290,0 14 12118 5 G 95 56,1 4560,0 8071,0 3/0
12080 5 G 2,5 12,9 120,0 347,0 14 12119 4 G 120 56,6 4608,0 8170,0 4/0
12081 7 G 2,5 14,2 168,0 420,0 14 12327 4 G 150 64,7 5760,0 9970,0 300 kcmil
12082 12 G 2,5 17,7 288,0 660,0 14
12083 14 G 2,5 18,8 336,0 750,0 14
12084 18 G 2,5 21,0 432,0 893,0 14
12085 20 G 2,5 22,3 480,0 1169,0 14
12086 25 G 2,5 24,8 600,0 1458,0 14
12087 30 G 2,5 26,0 720,0 1686,0 14
12088 34 G 2,5 28,4 816,0 1869,0 14
12089 50 G 2,5 34,0 1200,0 2200,0 14
12090 61 G 2,5 36,2 1464,0 3000,0 14

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

56
Flexible Control Cables / PVC Control Cables

H05VVC4V5-K (NYSLYCY-JZ) flexible, number coded,


oil resistant, EMC-preferred type
A

Technical data Cable structure Properties


Spezial-PVC control cable with Bare copper-conductor, to The materials used in manufacture are
oil resistant outer sheath acc. to DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN VDE 0285-525-2-51/ BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
DIN EN 50525-2-51 and IEC 60227/74 Core insulation of special PVC the wetting properties of lacquers
Temperature range compound type TI2 to Tests
flexing -5C to +70C DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
fixed installation -40C to +70C Core identification to DIN VDE 0293 acc. to DIN VDE 0482-332-1-2,
Nominal voltage U0/U 300/500 V black cores with continuous white DIN EN 60332-1-2, IEC 60332-1 (equivalent
Test voltage numbering DIN VDE 0472 part 804 test method B)
core/core 2 kV, 5 minutes GN-YE conductor, 3 cores and above Oil resistant to DIN EN 60811-404
core/screen 2 kV, 5 minutes in the outer layer
Breakdown voltage min. 4000 V Cores stranded in layers with Note
Coupling resistance optimal lay-length G = with green-yellow conductor
at 30 MHz 250 Ohm/km Inner sheath of special PVC x = without green-yellow conductor (OZ)
Insulation resistance compound type TM2 to AWG sizes are approximate equivalent
min. 20 MOhm x km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 values. The actual cross-section is in mm.
Minimum bending radius Tinned copper braided screening, unscreened analogue type:
flexing 10x cable covering approx. 85% H05VV5-F (NYSLY-JZ), confer page 35
fixed installation 5x cable Outer sheath of special PVC
Radiation resistance compound type TM5 to
up to 80x106 cJ/kg (up to 80 Mrad) DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Sheath colour grey (RAL 7001)

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and
production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants
and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement. The interconnection of
parts of machines used for manufacturing purposes including machine tools where some degree of protection against electromagnetic interference
is required.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13951 2 x 0,5 7,7 - 9,6 41,0 92,0 20 13957 2 x 0,75 8,0 - 10,0 46,0 102,0 19
13060 3 G 0,5 8,0 - 10,0 45,0 109,0 20 13072 3 G 0,75 8,3 - 10,4 57,0 115,0 19
13061 4 G 0,5 8,5 - 10,7 54,0 126,0 20 13073 4 G 0,75 9,1 - 11,3 63,0 150,0 19
13062 5 G 0,5 9,3 - 11,6 66,0 156,0 20 13074 5 G 0,75 9,7 - 12,1 76,0 173,0 19
13063 6 G 0,5 9,9 - 12,4 73,0 176,0 20 13075 6 G 0,75 10,5 - 13,1 82,0 195,0 19
13064 7 G 0,5 10,8 - 13,5 79,0 192,0 20 13076 7 G 0,75 11,5 - 14,3 100,0 235,0 19
13952 8 G 0,5 11,7 - 14,5 82,0 211,0 20 13958 8 G 0,75 12,1 - 15,0 112,0 268,0 19
13065 9 G 0,5 12,8 - 15,8 94,0 230,0 20 13077 9 G 0,75 13,3 - 16,5 130,0 285,0 19
13066 12 G 0,5 13,3 - 16,5 137,0 280,0 20 13078 12 G 0,75 13,9 - 17,2 175,0 327,0 19
13953 14 G 0,5 13,4 - 16,6 142,0 302,0 20 13959 14 G 0,75 14,4 - 17,7 190,0 362,0 19
13067 18 G 0,5 15,1 - 18,6 156,0 384,0 20 13079 18 G 0,75 16,2 - 19,9 240,0 488,0 19
13068 25 G 0,5 17,7 - 21,7 250,0 556,0 20 13080 25 G 0,75 18,7 - 22,6 306,0 654,0 19
13954 27 G 0,5 18,0 - 22,1 255,0 599,0 20 13960 27 G 0,75 19,3 - 23,7 326,0 708,0 19
13069 34 G 0,5 20,1 - 24,7 316,0 634,0 20 13081 34 G 0,75 21,3 - 26,2 346,0 821,0 19
13955 36 G 0,5 20,1 - 24,7 320,0 620,0 20 13961 36 G 0,75 21,3 - 26,2 358,0 899,0 19
13129 41 G 0,5 21,7 - 26,6 348,0 770,0 20 13130 41 G 0,75 23,1 - 28,3 403,0 970,0 19
13070 50 G 0,5 24,0 - 29,3 407,0 970,0 20 13082 50 G 0,75 25,3 - 31,0 470,0 1160,0 19
13071 61 G 0,5 25,5 - 31,1 520,0 1072,0 20 13083 61 G 0,75 27,0 - 32,9 550,0 1402,0 19
13956 65 G 0,5 26,1 - 31,9 563,0 1198,0 20 13962 65 G 0,75 27,8 - 34,0 594,0 1504,0 19

Continuation

57
Flexible Control Cables / PVC Control Cables

H05VVC4V5-K (NYSLYCY-JZ) flexible, number coded,


oil resistant, EMC-preferred type
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13963 2x1 8,2 - 10,3 54,0 114,0 18 13973 14 G 1,5 17,6 - 21,6 294,0 560,0 16
13084 3G1 8,8 - 11,0 64,0 142,0 18 13103 18 G 1,5 19,6 - 24,1 386,0 707,0 16
13085 4G1 9,4 - 11,7 76,0 175,0 18 13974 19 G 1,5 19,6 - 24,1 394,0 723,0 16
13086 5G1 10,3 - 12,8 89,0 205,0 18 13104 25 G 1,5 22,7 - 27,8 531,0 950,0 16
13087 6G1 11,0 - 13,6 101,0 236,0 18 13975 27 G 1,5 23,4 - 28,6 546,0 1014,0 16
13088 7G1 12,2 - 15,1 114,0 264,0 18 13105 32 G 1,5 25,4 - 31,1 638,0 1133,0 16
13964 8G1 13,1 - 16,2 130,0 301,0 18 13106 34 G 1,5 26,6 - 32,5 671,0 1204,0 16
13089 9G1 13,9 - 17,2 144,0 335,0 18 13976 36 G 1,5 26,6 - 32,5 700,0 1261,0 16
13090 12 G 1 14,7 - 18,1 186,0 420,0 18 13977 37 G 1,5 26,6 - 32,5 720,0 1300,0 16
13965 14 G 1 15,3 - 18,8 198,0 433,0 18 13132 41 G 1,5 28,5 - 34,8 840,0 1453,0 16
13091 18 G 1 16,9 - 20,8 284,0 561,0 18 13107 50 G 1,5 31,2 - 38,0 997,0 1663,0 16
13966 19 G 1 16,9 - 20,8 307,0 584,0 18 13108 61 G 1,5 32,7 - 39,9 1120,0 1852,0 16
13092 25 G 1 19,8 - 24,2 387,0 766,0 18 13978 65 G 1,5 33,4 - 40,7 1197,0 1971,0 16
13967 27 G 1 20,2 - 24,7 410,0 822,0 18 13985 2 x 2,5 10,7 - 13,3 110,0 190,0 14
13093 34 G 1 22,5 - 27,6 500,0 996,0 18 13109 3 G 2,5 11,3 - 14,0 148,0 243,0 14
13968 36 G 1 22,5 - 27,6 511,0 1001,0 18 13110 4 G 2,5 12,6 - 15,5 169,0 280,0 14
13969 37 G 1 22,5 - 27,6 523,0 1018,0 18 13111 5 G 2,5 13,9 - 17,2 220,0 342,0 14
13131 41 G 1 24,7 - 30,2 578,0 1155,0 18 13112 7 G 2,5 16,5 - 20,3 284,0 439,0 14
13094 50 G 1 26,8 - 32,7 681,0 1300,0 18 13979 8 G 2,5 17,7 - 21,8 314,0 489,0 14
13095 61 G 1 28,5 - 34,7 710,0 1500,0 18 13113 12 G 2,5 19,9 - 24,4 470,0 760,0 14
13970 65 G 1 29,4 - 35,8 769,0 1510,0 18 13980 14 G 2,5 20,9 - 25,6 504,0 890,0 14
13971 2 x 1,5 9,3 - 11,6 64,0 146,0 16 13114 18 G 2,5 23,3 - 28,5 572,0 1052,0 14
13096 3 G 1,5 9,7 - 12,1 82,0 176,0 16 13115 25 G 2,5 27,4 - 33,5 740,0 1375,0 14
13097 4 G 1,5 10,7 - 13,2 99,0 207,0 16 13981 27 G 2,5 28,2 - 34,5 971,0 1507,0 14
13098 5 G 1,5 11,8 - 14,7 123,0 235,0 16 13116 34 G 2,5 31,5 - 38,5 1179,0 1892,0 14
13099 6 G 1,5 12,7 - 15,7 125,0 279,0 16 13982 36 G 2,5 31,5 - 38,5 1268,0 1998,0 14
13100 7 G 1,5 14,1 - 17,4 148,0 314,0 16 13983 41 G 2,5 33,5 - 40,8 1473,0 2286,0 14
13972 8 G 1,5 14,9 - 18,3 172,0 345,0 16 13117 50 G 2,5 36,5 - 44,4 1660,0 2673,0 14
13101 9 G 1,5 16,0 - 19,7 187,0 380,0 16 13118 61 G 2,5 38,8 - 47,2 1992,0 3085,0 14
13102 12 G 1,5 16,7 - 20,5 274,0 500,0 16

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

58
Flexible Control Cables / PVC Control Cables

(H)05VVC4V5-K ((N)YSLYCY-JZ) number coded,


screened, oil resistant, EMC-preferred type
A

Technical data Cable structure Properties


Spezial-PVC control cable with Bare copper-conductor, to The materials used in manufacture are
oil resistant outer sheath adapted to DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN VDE 0285-525-2-51/ BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
DIN EN 50525-2-51 and IEC 60227/74 Core insulation of special PVC the wetting properties of lacquers
deviation of conductor cross-sections compound type TI2 to Tests
Temperature range DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
flexing -5C to +70C Core identification to DIN VDE 0293 acc. to DIN VDE 0482-332-1-2,
fixed installation -40C to +70C black cores with continuous white DIN EN 60332-1-2, IEC 60332-1 (equivalent
Nominal voltage U0/U 300/500 V numbering DIN VDE 0472 part 804 test method B)
Test voltage GN-YE conductor, 3 cores and above Oil resistant to DIN EN 60811-404
core/core 2 kV, 5 min in the outer layer
core/screen 2 kV, 5 min Cores stranded in layers with Note
Breakdown voltage min. 4000 V optimal lay-length G = with green-yellow conductor
Coupling resistance Inner sheath of special PVC x = without green-yellow conductor (OZ)
at 30 MHz 250 Ohm/km compound type TM2 to AWG sizes are approximate equivalent
Insulation resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1 values. The actual cross-section is in mm.
min. 20 MOhm x km Tinned copper braided screen, unscreened analogue type:
Minimum bending radius approx. 85% coverage (H)05VV5-F (N)YSLY-JZ, confer page 37
flexing 10x cable Outer sheath of special PVC
fixed installation 5x cable compound type TM5 to
Radiation resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour grey (RAL 7001)
with meter marking

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and
production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants
and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.
The interconnection of parts of machines used for manufacturing purposes including machine tools where some degree of protection against
electromagnetic interference is required.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
13170 2x4 12,8 124,0 236,0 12 13190 3 G 16 23,0 653,0 993,0 6
13171 3G4 13,8 178,0 361,0 12 13191 4 G 16 25,2 807,0 1340,0 6
13172 4G4 14,9 234,0 430,0 12 13192 5 G 16 27,8 940,0 1626,0 6
13173 5G4 16,3 284,0 509,0 12 13193 7 G 16 33,9 1345,0 2080,0 6
13175 7G4 19,5 321,0 660,0 12 13196 4 G 25 30,7 1169,0 1692,0 4
13178 12 G 4 23,5 581,0 979,0 12 13197 5 G 25 34,1 1420,0 1972,0 4
13179 2x6 14,2 176,0 296,0 10 13198 3 G 35 31,0 1250,0 1704,0 2
13180 3G6 15,2 245,0 420,0 10 13199 4 G 35 34,1 1680,0 2320,0 2
13181 4G6 16,5 316,0 579,0 10 13189 5 G 35 37,3 2020,0 2780,0 2
13182 5G6 18,3 442,0 719,0 10 13194 3 G 50 35,7 1887,0 2661,0 1
13183 7G6 21,7 530,0 1031,0 10 13195 4 G 50 37,7 2370,0 3194,0 1
13185 3 G 10 18,8 367,0 655,0 8 13184 5 G 50 42,7 2880,0 4247,0 1
13186 4 G 10 20,7 549,0 894,0 8
13187 5 G 10 22,7 604,0 927,0 8
13188 7 G 10 27,8 820,0 1518,0 8

Dimensions and specifications may be changed without prior notice. (RA01)

59
Flexible Control Cables / PVC Control Cables

JZ-600-Y-CY flexible, number coded, 0,6/1kV, Cu screened meter marking,


EMC-preferred type

Technical data Cable structure Properties


Adapted to DIN VDE 0262 Bare copper-conductor, to Extensively oil resistant,
and DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of Special PVC The materials used in manufacture are
flexing -15C to +80C compound type TI2 to cadmium-free and contain no silicone
fixed installation -40C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 and free from substances harmful to
Nominal voltage U0/U 0,6/1 kV Core identification to DIN VDE 0293 the wetting properties of lacquers
Test voltage 4000 V black cores with continuous white UV resistant
Breakdown voltage min. 8000 V numbering Tests
Insulation resistance GN-YE conductor, 3 cores and above PVC self-extinguishing and flame retardant
min. 20 MOhm x km in the outer layer acc. to DIN VDE 0482-332-1-2,
Coupling resistance Cores stranded in layers with DIN EN 60332-1-2, IEC 60332-1 (equivalent
max. 250 Ohm/km optimal lay-length DIN VDE 0472 part 804 test method B)
Minimum bending radius Inner sheath of PVC
flexing 10x cable Tinned copper braided screen, Note
fixed installation 5x cable approx. 85% coverage G = with green-yellow conductor
Radiation resistance Outer sheath of special PVC x = without green-yellow conductor (OZ)
up to 80x106 cJ/kg (up to 80 Mrad) compound type TM2 to Further sizes are available on request.
DIN VDE 0207-363-4-1/DIN EN 50363-4-1 AWG sizes are approximate equivalent
Sheath colour black (RAL 9005) values. The actual cross-section is in mm.
with meter marking unscreened analogue type:
JZ-600, confer page 40

Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning
and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burial- or as
underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back
a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath
is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. Interference-free transmission of signals and
pulses is assured by the high degree of screening.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11464 2 x 0,5 8,5 41,0 129,0 20 11516 2x1 9,2 54,0 150,0 18
11465 3 G 0,5 8,8 45,0 150,0 20 11517 3G1 9,8 64,0 163,0 18
11466 4 G 0,5 9,4 54,0 170,0 20 11518 4G1 10,4 76,0 200,0 18
11467 5 G 0,5 10,2 66,0 199,0 20 11519 5G1 11,4 89,0 239,0 18
11469 7 G 0,5 10,8 79,0 235,0 20 11521 7G1 12,3 114,0 289,0 18
11472 12 G 0,5 14,3 137,0 320,0 20 11525 12 G 1 15,9 186,0 464,0 18
11475 18 G 0,5 16,4 156,0 428,0 20 11528 18 G 1 18,2 284,0 628,0 18
11478 25 G 0,5 19,3 250,0 503,0 20 11532 25 G 1 22,0 387,0 855,0 18
11489 2 x 0,75 8,8 46,0 143,0 19 11546 2 x 1,5 10,4 64,0 162,0 16
11490 3 G 0,75 9,1 57,0 155,0 19 11547 3 G 1,5 10,8 82,0 187,0 16
11491 4 G 0,75 9,9 63,0 190,0 19 11548 4 G 1,5 11,5 99,0 240,0 16
11492 5 G 0,75 10,6 76,0 228,0 19 11549 5 G 1,5 13,0 123,0 289,0 16
11494 7 G 0,75 11,5 100,0 323,0 19 11551 7 G 1,5 14,2 148,0 383,0 16
11498 12 G 0,75 15,0 175,0 410,0 19 11556 12 G 1,5 18,4 274,0 592,0 16
11501 18 G 0,75 17,2 240,0 560,0 19 11559 18 G 1,5 21,3 386,0 806,0 16
11504 25 G 0,75 20,6 306,0 730,0 19 11563 25 G 1,5 25,4 531,0 1241,0 16

Continuation

60
Flexible Control Cables / PVC Control Cables

JZ-600-Y-CY flexible, number coded, 0,6/1kV, Cu screened meter marking,


EMC-preferred type
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11574 2 x 2,5 11,8 110,0 272,0 14 11608 3 G 16 23,4 653,0 1395,0 6
11575 3 G 2,5 12,8 148,0 298,0 14 11609 4 G 16 25,7 807,0 1870,0 6
11576 4 G 2,5 13,8 169,0 345,0 14 11610 5 G 16 28,5 940,0 2720,0 6
11577 5 G 2,5 15,0 220,0 427,0 14 11611 7 G 16 31,4 1345,0 3213,0 6
11578 7 G 2,5 16,3 284,0 561,0 14 11612 3 G 25 28,2 920,0 2465,0 4
11580 12 G 2,5 21,6 470,0 857,0 14 11613 4 G 25 31,3 1169,0 2750,0 4
11582 18 G 2,5 25,2 572,0 1355,0 14 11614 5 G 25 34,5 1420,0 3490,0 4
11584 25 G 2,5 30,0 740,0 1995,0 14 11615 7 G 25 37,8 1921,0 4980,0 4
11590 2x4 13,6 124,0 306,0 12 11616 3 G 35 31,2 1250,0 3230,0 2
11591 3G4 14,6 178,0 391,0 12 11617 4 G 35 34,5 1680,0 4100,0 2
11592 4G4 15,7 234,0 527,0 12 11618 5 G 35 38,0 2020,0 4950,0 2
11593 5G4 17,2 284,0 700,0 12 11619 3 G 50 36,5 1887,0 4590,0 1
11594 7G4 18,9 321,0 920,0 12 11620 4 G 50 40,5 2370,0 5780,0 1
11596 12 G 4 24,5 581,0 1510,0 12 11621 5 G 50 45,2 2880,0 7210,0 1
11597 2x6 14,9 176,0 420,0 10 11622 3 G 70 41,8 2516,0 5610,0 2/0
11598 3G6 15,9 245,0 629,0 10 11623 4 G 70 46,0 3257,0 7480,0 2/0
11599 4G6 17,4 316,0 731,0 10 11624 5 G 70 50,4 4032,0 9390,0 2/0
11600 5G6 19,2 442,0 1105,0 10 11625 3 G 95 46,8 3086,0 8585,0 3/0
11601 7G6 20,9 530,0 1465,0 10 11626 4 G 95 51,3 4060,0 10220,0 3/0
11602 2 x 10 18,6 260,0 845,0 8 11627 5 G 95 56,1 5244,0 13800,0 3/0
11603 3 G 10 19,8 367,0 1125,0 8 11628 3 G 120 51,8 4176,0 11105,0 4/0
11604 4 G 10 21,5 549,0 1345,0 8 11629 4 G 120 56,3 5231,0 13750,0 4/0
11605 5 G 10 23,5 604,0 1635,0 8 13137 4 G 150 64,4 7760,0 15990,0 300 kcmil
11606 7 G 10 25,6 820,0 2210,0 8 13147 4 G 185 69,5 8104,0 18470,0 350 kcmil
11607 2 x 16 21,8 491,0 1150,0 6

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

61
Flexible Control Cables / PVC Control Cables

Y-CY-JB flexible, Cu-screened, transparent, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper, fine wire conductors, bunch Extensively oil resistant,
to DIN VDE 0285-525-2-51/ stranded to DIN VDE 0295 cl.5, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5 and IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -15C to +80C compound type Z 7225 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to JB/OB colour code and free from substances harmful to
Nominal voltage GN-YE conductor, 3 cores and above the wetting properties of lacquers
up to 1,5 mm U0/U 300/500 V in the outer layer Tests
from 2,5 mm U0/U 450/750 V Cores stranded in layers with PVC self-extinguishing and flame retardant
Test voltage 4000 V optimal lay-length acc. to DIN VDE 0482-332-1-2,
Breakdown voltage min. 8000 V Inner sheath of PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
Insulation resistance Tinned copper braided screen, DIN VDE 0472 part 804 test method B)
min. 20 MOhm x km approx. 85% coverage
Mutual capacitance Outer sheath of special PVC Note
acc. to different cross-sections Sheath colour transparent G = with green-yellow conductor
0,5 up to 2,5 mm: with meter marking x = without green-yellow conductor (OB).
core/core approx. 150 nF/km up to 5 cores and cunductor cross-section up
core/screen approx. 270 nF/km to 1,5 mm with VDE-Reg. No.
Coupling resistance AWG sizes are approximate equivalent
max. 250 Ohm/km values. The actual cross-section is in mm.
Minimum bending radius unscreened analogue type:
flexing 10x cable JB-500, confer page 42
fixed installation 5x cable JB-750, confer page 43
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a
high degree of interference protection. The screening density assures disturbance-free transmission of all signals and impulses. The PVC-inner sheaths
of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical view of the tinned copper braid.
These cables are suitable for flexible use for medium mechanical stresses with free movements. The dense screening assures disturbance-free transmission
of all signals and impulses. An ideal disturbance-free control cable for the above application.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16121 2 x 0,5 7,0 41,0 67,0 20 16137 2 x 2,5 11,1 110,0 180,0 14
16122 3 G 0,5 7,3 45,0 83,0 20 16138 3 G 2,5 11,6 148,0 216,0 14
16123 4 G 0,5 7,9 54,0 94,0 20 16139 4 G 2,5 12,7 169,0 267,0 14
16124 5 G 0,5 8,4 66,0 108,0 20 16140 5 G 2,5 14,1 220,0 347,0 14
16125 2 x 0,75 7,7 46,0 87,0 19 16141 2x4 13,3 124,0 302,0 12
16126 3 G 0,75 8,0 57,0 98,0 19 16142 3G4 14,0 178,0 340,0 12
16127 4 G 0,75 8,5 63,0 113,0 19 16143 4G4 15,3 234,0 410,0 12
16128 5 G 0,75 9,3 76,0 130,0 19 16144 5G4 16,7 284,0 502,0 12
16129 2x1 8,0 54,0 97,0 18 16145 2x6 14,7 176,0 350,0 10
16130 3G1 8,3 64,0 103,0 18 16146 3G6 15,6 245,0 450,0 10
16131 4G1 9,0 76,0 146,0 18 16147 4G6 17,0 316,0 559,0 10
16132 5G1 9,7 89,0 169,0 18 16148 5G6 18,6 442,0 702,0 10
16133 2 x 1,5 8,6 64,0 130,0 16 16149 2 x 10 18,0 260,0 500,0 8
16134 3 G 1,5 9,2 82,0 152,0 16 16150 3 G 10 19,0 367,0 750,0 8
16135 4 G 1,5 9,8 99,0 168,0 16 16151 4 G 10 21,1 549,0 1020,0 8
16136 5 G 1,5 10,8 123,0 202,0 16 16152 5 G 10 23,1 604,0 1115,0 8

Continuation

62
Flexible Control Cables / PVC Control Cables

Y-CY-JB flexible, Cu-screened, transparent, EMC-preferred type, meter marking

Part no. No.cores x


cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No. Part no. No.cores x
cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No.
A
16153 4 G 16 25,3 807,0 1380,0 6 16471 4 G 50 40,1 2370,0 3315,0 1
16154 5 G 16 28,0 940,0 1553,0 6 16119 5 G 50 45,0 2880,0 4150,0 1
16469 4 G 25 31,1 1169,0 1890,0 4 16472 4 G 70 46,0 3257,0 4600,0 2/0
16155 5 G 25 34,3 1420,0 2270,0 4 16473 4 G 95 51,2 4060,0 6060,0 3/0
16470 4 G 35 33,9 1680,0 2390,0 2 16474 4 G 120 56,3 5231,0 7315,0 4/0
16156 5 G 35 37,8 2020,0 2885,0 2 16247 4 G 150 64,7 7760,0 9340,0 300 kcmil
16319 4 G 185 69,5 8104,0 11120,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

63
Flexible Control Cables / PVC Control Cables

SY-JB flexible, colour coded, with steel wire braiding, meter marking

Technical data Cable structure Properties


Special-PVC control cable adapted Bare copper-conductor, to Extensively oil resistant,
to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
DIN EN 50525-2-51 BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -15Cto +80C compound type Z 7225 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to JB/OB colour code and free from substances harmful to
Nominal voltage GN-YE conductor, 3 cores and above the wetting properties of lacquers
up to 2,5 mm U0/U 300/500 V in the outer layer Tests
from 4,0 mm U0/U 450/750 V Cores stranded in layers with PVC self-extinguishing and flame retardant
Test voltage 4000 V optimal lay-length acc. to DIN VDE 0482-332-1-2,
Breakdown voltage min. 8000 V Inner sheath of special PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
Insulation resistance Galvanized steel wire screening DIN VDE 0472 part 804 test method B)
min. 20 MOhm x km Outer sheath of special PVC
Minimum bending radius compound type TM2 to Note
flexing 20x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1 G = with green-yellow conductor
fixed installation 6x cable Sheath colour transparent x = without green-yellow conductor (OB).
Radiation resistance with meter marking up to 5 cores and conductor cross-section up
up to 80x106 cJ/kg (up to 80 Mrad) to 2,5 mm with VDE Reg.-No.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification when
ordering.
screened analogue type:
SY-JZ, confer page 55

Application
SY-JB cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The braided screen
offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect against corrosion,
but also notably improves the soldering performance.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12200 2 x 0,5 7,2 9,6 80,0 20 12277 2 x 2,5 10,2 48,0 185,0 14
12201 3 G 0,5 7,5 14,4 92,0 20 12278 3 G 2,5 10,9 72,0 248,0 14
12202 4 G 0,5 8,1 19,2 102,0 20 12279 4 G 2,5 11,6 96,0 290,0 14
12203 5 G 0,5 8,6 24,0 119,0 20 12280 5 G 2,5 12,9 120,0 347,0 14
12204 7 G 0,5 9,3 33,6 157,0 20 12281 7 G 2,5 14,2 168,0 420,0 14
12205 10 G 0,5 10,7 48,0 205,0 20 12282 12 G 2,5 17,7 288,0 660,0 14
12206 12 G 0,5 11,7 58,0 218,0 20 12291 2x4 13,6 77,0 330,0 12
12218 2 x 0,75 7,9 14,4 98,0 19 12318 3G4 14,3 115,0 375,0 12
12219 3 G 0,75 8,2 21,6 103,0 19 12292 4G4 15,4 154,0 428,0 12
12220 4 G 0,75 8,7 28,8 122,0 19 12293 5G4 16,9 192,0 504,0 12
12221 5 G 0,75 9,5 36,0 142,0 19 12294 7G4 18,4 269,0 640,0 12
12312 6 G 0,75 10,1 43,2 180,0 19 12295 3G6 15,6 173,0 543,0 10
12222 7 G 0,75 10,1 50,0 185,0 19 12296 4G6 17,0 230,0 571,0 10
12223 9 G 0,75 11,8 65,0 249,0 19 12297 5G6 18,6 288,0 671,0 10
12313 10 G 0,75 12,0 72,0 252,0 19 12298 7G6 20,6 403,0 845,0 10
12224 12 G 0,75 12,8 86,0 292,0 19 12319 3 G 10 19,2 288,0 735,0 8
12234 2x1 8,2 19,2 112,0 18 12299 4 G 10 21,1 384,0 943,0 8
12235 3G1 8,5 28,8 132,0 18 12300 5 G 10 23,3 480,0 1065,0 8
12236 4G1 9,2 38,4 143,0 18 12301 7 G 10 25,4 672,0 1551,0 8
12237 5G1 9,9 48,0 166,0 18 12320 3 G 16 23,0 461,0 1080,0 6
12238 6G1 10,5 58,0 220,0 18 12302 4 G 16 25,5 614,0 1360,0 6
12239 7G1 10,5 67,0 227,0 18 12303 5 G 16 28,2 768,0 1740,0 6
12240 8G1 11,4 77,0 277,0 18 12304 7 G 16 30,8 1075,0 2166,0 6
12241 9G1 12,8 86,0 295,0 18 12321 3 G 25 28,2 720,0 1630,0 4
12242 12 G 1 13,4 115,0 340,0 18 12305 4 G 25 31,0 960,0 2020,0 4
12256 2 x 1,5 8,8 29,0 129,0 16 12306 5 G 25 34,3 1200,0 2465,0 4
12257 3 G 1,5 9,4 43,0 149,0 16 12322 3 G 35 31,0 1008,0 1932,0 2
12258 4 G 1,5 10,0 58,0 185,0 16 12307 4 G 35 34,0 1344,0 2570,0 2
12259 5 G 1,5 10,9 72,0 205,0 16 12308 5 G 35 38,0 1680,0 3185,0 2
12260 6 G 1,5 11,8 87,0 255,0 16 12323 3 G 50 36,7 1440,0 2679,0 1
12261 7 G 1,5 11,8 101,0 285,0 16 12309 4 G 50 40,4 1920,0 3513,0 1
12262 8 G 1,5 12,7 115,0 340,0 16 12314 5 G 50 45,2 2400,0 4248,0 1
12263 9 G 1,5 13,9 130,0 347,0 16 12324 3 G 70 42,3 2016,0 2790,0 2/0
12264 10 G 1,5 14,3 144,0 418,0 16 12310 4 G 70 46,2 2688,0 4810,0 2/0
12265 11 G 1,5 14,8 158,0 430,0 16 12315 5 G 70 50,5 3360,0 5880,0 2/0
12266 12 G 1,5 15,0 173,0 444,0 16

Continuation

64
Flexible Control Cables / PVC Control Cables

SY-JB flexible, colour coded, with steel wire braiding, meter marking

Part no. No.cores x


cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No. Part no. No.cores x
cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No.
A
12325 3 G 95 47,2 2736,0 4870,0 3/0 12326 3 G 120 51,9 3456,0 6230,0 4/0
12311 4 G 95 51,3 3648,0 6360,0 3/0 12317 4 G 120 56,4 4608,0 8170,0 4/0
12316 5 G 95 56,3 4560,0 8071,0 3/0 12328 4 G 150 64,4 5760,0 9970,0 300 kcmil

Dimensions and specifications may be changed without prior notice. (RA01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

65
PUR CONTROL CABLES

66
Flexible Control Cables / PUR Control Cables

JZ-500 PUR tear and coolant resistant, meter marking

Technical data Cable structure Properties


Special-PUR control cable adapted to Bare copper-conductor, to Resistant to
DIN VDE 0285-525-1 / DIN EN 50525-1 DIN VDE 0295 cl.5, fine-wire, UV-Radiation, Oxygene, Ozone and
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Hydrolysis, Microbes
flexing -15C to +80C Core insulation of special PVC Low adhesion, matt surface
fixed installation -40C to +80C compound type TI2 to The materials used in manufacture are
Nominal voltage U0/U 300/500 V DIN VDE 0207-363-3/ DIN EN 50363-3 cadmium-free and contain no silicone
Test voltage 4000 V Core identification to DIN VDE 0293 and free from substances harmful to
Breakdown voltage min. 8000 V black cores with continuous white the wetting properties of lacquers
Insulation resistance numbering
min. 20 MOhm x km GN-YE conductor, 3 cores and above Note
Minimum bending radius in the outer layer G = with green-yellow conductor
flexing 7,5x cable Cores stranded in layers with x = without green-yellow conductor (OZ)
fixed installation 4x cable optimal lay-length AWG sizes are approximate equivalent
Radiation resistance Outer sheath of special full-polyurethane values. The actual cross-section is in mm.
up to 100x106 cJ/kg (up to 100 Mrad) compound type TMPU to screened analogue type:
DIN EN 50363-10-2 JZ-500-FC-PUR, confer page 76
Sheath colour grey (RAL 7001)
also available in other colours
with meter marking

Application
JZ-500 PUR is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance coolant emulsions, it is
especially suited for use in the machine, tool making and plant industries as well as in the steel industry for difficult and problem areas. The high
flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
23314 2 x 0,5 4,8 9,6 45,0 20 23352 7x1 8,1 67,0 115,0 18
23315 3 G 0,5 5,1 14,4 55,0 20 23353 10 G 1 9,8 96,0 166,0 18
23316 3 x 0,5 5,1 14,4 55,0 20 23354 12 G 1 10,4 115,0 201,0 18
23317 4 G 0,5 5,5 19,0 65,0 20 23355 18 G 1 12,9 173,0 289,0 18
23318 4 x 0,5 5,5 19,0 65,0 20 23356 25 G 1 15,4 240,0 380,0 18
23319 5 G 0,5 6,2 24,0 75,0 20 23357 34 G 1 17,7 326,0 645,0 18
23320 5 x 0,5 6,2 24,0 75,0 20 23358 42 G 1 19,5 403,0 730,0 18
23321 7 G 0,5 6,7 33,6 90,0 20 23359 50 G 1 21,3 480,0 890,0 18
23322 7 x 0,5 6,7 33,6 90,0 20 23360 2 x 1,5 6,4 29,0 68,0 16
23323 10 G 0,5 8,3 48,0 120,0 20 23361 3 G 1,5 6,8 43,0 87,0 16
23324 12 G 0,5 8,7 58,0 135,0 20 23362 3 x 1,5 6,8 43,0 87,0 16
23325 18 G 0,5 10,7 86,0 205,0 20 23363 4 G 1,5 7,4 58,0 106,0 16
23326 25 G 0,5 12,6 120,0 270,0 20 23364 4 x 1,5 7,4 58,0 106,0 16
23327 34 G 0,5 14,3 163,0 380,0 20 23365 5 G 1,5 8,3 72,0 131,0 16
23328 42 G 0,5 15,8 202,0 415,0 20 23366 5 x 1,5 8,3 72,0 131,0 16
23329 2 x 0,75 5,3 14,4 44,0 19 23367 7 G 1,5 9,2 101,0 173,0 16
23330 3 G 0,75 5,6 21,6 53,0 19 23368 7 x 1,5 9,2 101,0 173,0 16
23331 3 x 0,75 5,6 21,6 53,0 19 23369 12 G 1,5 11,8 173,0 293,0 16
23332 4 G 0,75 6,3 29,0 64,0 19 23370 18 G 1,5 14,6 259,0 454,0 16
23333 4 x 0,75 6,3 29,0 64,0 19 23371 25 G 1,5 17,4 360,0 641,0 16
23334 5 G 0,75 6,9 36,0 76,0 19 23372 30 G 1,5 18,6 410,0 800,0 16
23335 5 x 0,75 6,9 36,0 76,0 19 23373 2 x 2,5 7,8 48,0 110,0 14
23336 7 G 0,75 7,5 50,0 96,0 19 23374 3 G 2,5 8,3 72,0 146,0 14
23337 7 x 0,75 7,5 50,0 96,0 19 23375 4 G 2,5 9,2 96,0 183,0 14
23338 10 G 0,75 9,2 72,0 140,0 19 23376 5 G 2,5 10,1 120,0 222,0 14
23339 12 G 0,75 9,8 86,0 170,0 19 23377 7 G 2,5 11,2 168,0 293,0 14
23340 18 G 0,75 12,2 130,0 260,0 19 23378 12 G 2,5 14,8 288,0 512,0 14
23341 25 G 0,75 14,3 180,0 282,0 19 23379 4G4 10,9 154,0 291,0 12
23342 34 G 0,75 16,5 245,0 475,0 19 23380 5G4 12,1 192,0 355,0 12
23343 42 G 0,75 18,1 302,0 600,0 19 23381 7G4 13,2 269,0 503,0 12
23344 2x1 5,6 19,0 53,0 18 23382 4G6 13,0 230,0 468,0 10
23345 3G1 5,6 29,0 63,0 18 23383 5G6 14,5 288,0 570,0 10
23346 3x1 5,9 29,0 63,0 18 23384 7G6 16,2 403,0 808,0 10
23347 4G1 6,6 38,0 75,0 18 23385 4 G 10 16,5 384,0 720,0 8
23348 4x1 6,6 38,0 75,0 18 23386 5 G 10 18,3 480,0 894,0 8
23349 5G1 7,3 48,0 89,0 18 23387 7 G 10 20,2 672,0 1295,0 8
23350 5x1 7,3 48,0 89,0 18 23388 4 G 16 20,1 614,0 1063,0 6
23351 7G1 8,1 67,0 115,0 18

Dimensions and specifications may be changed without prior notice. (RA02)

67
Flexible Control Cables / PUR Control Cables

PUR-JZ tear and coolant resistant, increased oil resistant, meter marking

Technical data Cable structure Properties


Special-PUR control cable adapted to Bare copper-conductor, to Resistant to
DIN VDE 0285-525-1 / DIN EN 50525-1 DIN VDE 0295 cl.5, fine-wire, UV-Radiation, Oxygene, Ozone
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Hydrolysis, Microbes
flexing -20C to +80C Core insualtion of oil resistant PVC The materials used in manufacture are
fixed installation -40C to +80C compound type TI2 adapted to cadmium-free and contain no silicone
Nominal voltage U0/U 300/500 V DIN VDE 0207-363-3 / DIN EN 50363-3, and free from substances harmful to
Test voltage 4000 V for better sliding abilities the wetting properties of lacquers
Breakdown voltage min. 8000 V Core identification to DIN VDE 0293
Insulation resistance black cores with continuous white Note
min. 20 MOhm x km numbering G = with green-yellow conductor
Minimum bending radius GN-YE conductor, 3 cores and above x = without green-yellow conductor (OZ)
flexing 7,5x cable in the outer layer AWG sizes are approximate equivalent
fixed installation 4x cable Cores stranded in layers with values. The actual cross-section is in mm.
Radiation resistance optimal lay-length screened analogue type:
up to 100x106 cJ/kg (up to 100 Mrad) Outer sheath of special full-polyurethane F-C-PUR-JZ, confer page 78,
compound type TMPU to Y-C-PUR-JZ, confer page 80
DIN EN 50363-10-2
Sheath colour grey (RAL 7001)
also available in other colours on request
with meter marking

Application
PUR-JZ is an extremely robust control cable with high abrasion and tear resistant properties. With high-grade oil resistant PVC core insulation. Due
to its high resistance to mineral oils and especially to coolant emulsions, it is especially suited for use in the machine, tool making, plant construction
as well as in the steel industry for difficult and problem areas. For medium mechanical stress for flexible use with free movement without tensile stress
or forced movements in dry, damp and wet rooms and in open air. The high flexibility of this cable type makes it quick and easy to install.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22100 2 x 0,5 4,8 9,6 45,0 20 22132 2x1 5,6 19,0 53,0 18
22101 3 G 0,5 5,1 14,4 55,0 20 22133 3G1 5,9 29,0 63,0 18
22102 4 G 0,5 5,5 19,0 65,0 20 22134 4G1 6,6 38,0 75,0 18
22103 5 G 0,5 6,2 24,0 75,0 20 22135 5G1 7,3 48,0 89,0 18
22104 7 G 0,5 6,7 33,6 90,0 20 22136 7G1 8,1 67,0 115,0 18
22105 8 G 0,5 7,4 38,0 105,0 20 22137 8G1 8,8 77,0 131,0 18
22106 10 G 0,5 8,3 48,0 120,0 20 22138 10 G 1 9,8 96,0 166,0 18
22107 12 G 0,5 8,7 58,0 135,0 20 22139 12 G 1 10,4 115,0 201,0 18
22108 14 G 0,5 9,5 67,0 170,0 20 22140 14 G 1 11,4 134,0 230,0 18
22109 18 G 0,5 10,7 86,0 205,0 20 22141 18 G 1 12,9 173,0 289,0 18
22110 21 G 0,5 11,3 96,0 225,0 20 22142 21 G 1 13,8 196,0 306,0 18
22111 25 G 0,5 12,6 120,0 270,0 20 22143 25 G 1 15,4 240,0 380,0 18
22112 30 G 0,5 13,5 144,0 315,0 20 22144 32 G 1 17,1 308,0 620,0 18
22113 34 G 0,5 14,3 163,0 380,0 20 22145 34 G 1 17,7 326,0 645,0 18
22114 42 G 0,5 15,8 202,0 415,0 20 22146 42 G 1 19,5 403,0 730,0 18
22115 50 G 0,5 17,5 240,0 550,0 20 22147 50 G 1 21,3 480,0 890,0 18
22116 2 x 0,75 5,3 14,4 44,0 19 22148 2 x 1,5 6,4 29,0 68,0 16
22117 3 G 0,75 5,6 21,6 53,0 19 22149 3 G 1,5 6,8 43,0 87,0 16
22118 4 G 0,75 6,3 29,0 64,0 19 22150 4 G 1,5 7,4 58,0 106,0 16
22119 5 G 0,75 6,9 36,0 76,0 19 22151 5 G 1,5 8,3 72,0 131,0 16
22120 7 G 0,75 7,5 50,0 96,0 19 22152 7 G 1,5 9,2 101,0 173,0 16
22121 8 G 0,75 8,3 58,0 111,0 19 22153 8 G 1,5 10,0 115,0 199,0 16
22122 10 G 0,75 9,2 72,0 140,0 19 22154 10 G 1,5 10,9 144,0 245,0 16
22123 12 G 0,75 9,8 86,0 170,0 19 22155 12 G 1,5 11,8 173,0 293,0 16
22124 14 G 0,75 10,6 101,0 202,0 19 22156 14 G 1,5 13,0 202,0 347,0 16
22125 18 G 0,75 12,2 130,0 260,0 19 22157 18 G 1,5 14,6 259,0 454,0 16
22126 21 G 0,75 12,7 151,0 269,0 19 22158 21 G 1,5 15,6 302,0 534,0 16
22127 25 G 0,75 14,3 180,0 282,0 19 22159 25 G 1,5 17,4 360,0 641,0 16
22128 30 G 0,75 15,3 216,0 400,0 19 22160 30 G 1,5 18,6 410,0 800,0 16
22129 34 G 0,75 16,5 245,0 475,0 19 22161 34 G 1,5 20,0 490,0 945,0 16
22130 42 G 0,75 18,1 302,0 600,0 19 22162 42 G 1,5 21,8 605,0 1100,0 16
22131 50 G 0,75 19,8 360,0 720,0 19 22163 50 G 1,5 24,2 720,0 1250,0 16

Continuation

68
Flexible Control Cables / PUR Control Cables

PUR-JZ tear and coolant resistant, increased oil resistant, meter marking

Part no. No.cores x


cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No. Part no. No.cores x
cross-sec.
mm
Outer Cop.
approx. mm weight
kg / km
Weight
approx.
kg / km
AWG-No.
A
22164 2 x 2,5 7,8 48,0 110,0 14 22181 3 G 10 14,9 288,0 555,0 8
22165 3 G 2,5 8,3 72,0 146,0 14 22182 4 G 10 16,5 384,0 720,0 8
22166 4 G 2,5 9,2 96,0 183,0 14 22183 5 G 10 18,3 480,0 894,0 8
22167 5 G 2,5 10,1 120,0 222,0 14 22184 7 G 10 20,2 672,0 1295,0 8
22168 7 G 2,5 11,2 168,0 293,0 14 22185 4 G 16 20,1 614,0 1063,0 6
22169 12 G 2,5 14,8 288,0 512,0 14 22186 5 G 16 22,6 768,0 1400,0 6
22170 18 G 2,5 18,2 432,0 740,0 14 22187 7 G 16 24,8 1075,0 1800,0 6
22171 25 G 2,5 21,6 600,0 940,0 14 22188 4 G 25 25,0 960,0 1590,0 4
22172 2x4 9,2 77,0 147,0 12 22189 4 G 35 28,7 1344,0 2200,0 2
22173 3G4 9,8 115,0 228,0 12 22190 4 G 50 34,1 1920,0 2400,0 1
22174 4G4 10,9 154,0 291,0 12 22191 4 G 70 40,2 2688,0 4400,0 2/0
22175 5G4 12,1 192,0 355,0 12 22192 4 G 95 46,0 3648,0 6000,0 3/0
22176 7G4 13,2 269,0 503,0 12
22177 3G6 11,9 173,0 362,0 10
22178 4G6 13,0 230,0 468,0 10
22179 5G6 14,5 288,0 570,0 10
22180 7G6 16,2 403,0 808,0 10

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS
Cable Gland - HELUTOP HT-E

69
Flexible Control Cables / PUR Control Cables

PUR-ORANGE high abrasion, coolant resistant, meter marking

Technical data Cable structure Properties


Special-PVC/PUR control cable Bare copper-conductor, to High flexibility at low temperature
adapted to DIN VDE 0285-525-1 / DIN VDE 0295 cl.5, fine-wire, High abrasion resistance
DIN EN 50525-1 BS 6360 cl.5, IEC 60228 cl.5 Resistant to
Temperature range Core insulation of special PVC Oils and fats
flexing -15C to +80C compound type TI2 adapted to Non-alcoholic fuels and kerosene
fixed installation -40C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 Atmospheric influences
Nominal voltage U0/U 300/500 V Core identification to DIN VDE 0293-308 UV-radiation
Test voltage 3000 V JZ/OZ-version: black cores with Oxygene and ozone
Breakdown voltage min. 6000 V continuous white numbering Microbes and rotting
Insulation resistance JB/OB-version: coloured cores Sea and waste water
min. 20 MOhm x km GN-YE conductor, 3 cores and above Vibrations
Minimum bending radius Cores stranded in layers with The materials used in manufacture are
flexing 7,5x cable optimal lay-length cadmium-free and contain no silicone
fixed installation 4x cable Inner sheath of PVC and free from substances harmful to
Radiation resistance guarantees easy cable stripping the wetting properties of lacquers
up to 100x106 cJ/kg (up to 100 Mrad) Outer sheath of PUR
comapound type TMPU to Note
DIN EN 50363-10-2 G = with green-yellow conductor
Sheath colour orange (RAL 2003) x = without green-yellow conductor (OZ/OB).
with meter marking AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Robust control cable with an outstanding resistance to oil and abrasion. Suitable for use in tool making and machine industries, steel works, on building
sites and in the oil and coal industries. The cable can also be used for portable tools etc. To be recommended if the cable comes into contact with
chemical agents.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
JZ/OZ-version: cores numbered JB/OB-version: cores colour coded
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22001 2 x 0,75 6,4 14,4 50,0 19 22250 2 x 0,75 6,4 14,4 50,0 19
22002 3 G 0,75 6,8 21,6 70,0 19 22251 3 G 0,75 6,8 21,6 70,0 19
22003 4 G 0,75 7,3 28,8 80,0 19 22252 4 G 0,75 7,3 28,8 80,0 19
22004 5 G 0,75 8,2 36,0 100,0 19 22253 5 G 0,75 8,2 36,0 100,0 19
22005 7 G 0,75 9,2 50,0 140,0 19 22254 2x1 7,2 19,2 63,0 18
22006 2x1 7,2 19,2 63,0 18 22255 3G1 7,6 29,0 76,0 18
22007 3G1 7,6 29,0 76,0 18 22256 4G1 8,0 38,0 95,0 18
22008 4G1 8,0 38,0 95,0 18 22257 5G1 8,8 48,0 120,0 18
22009 5G1 8,8 48,0 120,0 18 22258 2 x 1,5 7,8 29,0 80,0 16
22010 7G1 10,0 67,0 170,0 18 22259 3 G 1,5 8,3 43,0 105,0 16
22015 2 x 1,5 7,8 29,0 80,0 16 22260 4 G 1,5 9,0 58,0 135,0 16
22016 3 G 1,5 8,3 43,0 105,0 16 22261 5 G 1,5 9,7 72,0 158,0 16
22017 4 G 1,5 9,0 58,0 135,0 16 22262 2 x 2,5 9,2 48,0 150,0 14
22018 5 G 1,5 9,7 72,0 158,0 16 22263 3 G 2,5 9,6 72,0 173,0 14
22019 7 G 1,5 11,2 101,0 221,0 16 22264 4 G 2,5 11,0 96,0 203,0 14
22025 2 x 2,5 9,2 48,0 150,0 14 22265 5 G 2,5 12,0 120,0 253,0 14
22026 3 G 2,5 9,6 72,0 173,0 14 22266 4G4 13,2 154,0 300,0 12
22027 4 G 2,5 11,0 96,0 203,0 14 22267 5G4 14,8 192,0 370,0 12
22028 5 G 2,5 12,0 120,0 253,0 14 22268 4G6 15,4 230,0 480,0 10
22029 7 G 2,5 13,7 168,0 356,0 14 22269 5G6 17,0 288,0 583,0 10
22033 3G4 11,8 115,0 250,0 12 22270 4 G 10 20,8 384,0 740,0 8
22034 4G4 13,2 154,0 300,0 12 22271 5 G 10 22,6 480,0 920,0 8
22035 5G4 14,8 192,0 370,0 12 22272 4 G 16 23,0 614,0 1100,0 6
22036 7G4 16,4 269,0 500,0 12 22273 5 G 16 27,4 768,0 1400,0 6
22037 4G6 15,4 230,0 480,0 10 22044 4 G 25 30,0 960,0 1600,0 4
22038 5G6 17,0 288,0 583,0 10 22045 5 G 25 32,2 1200,0 2000,0 4
22039 7G6 20,8 403,0 780,0 10 22046 4 G 35 33,0 1344,0 2100,0 2
22040 4 G 10 20,8 384,0 740,0 8
22041 5 G 10 22,6 480,0 920,0 8
22042 4 G 16 23,0 614,0 1100,0 6
22043 5 G 16 27,4 768,0 1400,0 6

Dimensions and specifications may be changed without prior notice. (RA02)

70
Flexible Control Cables / PUR Control Cables

PUR-YELLOW PVC-inner sheath, high abrasion, coolant resistant, meter marking

Technical data Cable structure Properties


Special-PVC/PUR control cable Bare copper-conductor, to High flexibility at low temperature
adapted to DIN VDE 0285-525-1 / DIN VDE 0295 cl.5, fine-wire, High abrasion resistance
DIN EN 50525-1 BS 6360 cl.5, IEC 60228 cl.5 Resistant to
Temperature range Core insulation of special PVC Oils and fats
flexing -15C to +80C compound type TI2 adapted to Non-alcoholic fuels and kerosene
fixed installation -40C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 Atmospheric influences
Nominal voltage U0/U 300/500 V Core identification to DIN VDE 0293-308 UV-radiation
Test voltage 3000 V - up to 5 cores coloured Oxygene and ozone
Breakdown voltage min. 6000 V - from 6 cores, black with continuous Microbes and rotting
Insulation resistance white numbering Sea and waste water
min. 20 MOhm x km GN-YE conductor, 3 cores and above Vibrations
Minimum bending radius Cores stranded in layers with The materials used in manufacture are
flexing 7,5x cable optimal lay-length cadmium-free and contain no silicone
fixed installation 4x cable Inner sheath of PVC and free from substances harmful to
Radiation resistance guarantees easy cable stripping the wetting properties of lacquers
up to 100x106 cJ/kg (up to 100 Mrad) Outer sheath of PUR
compound type TMPU to Note
DIN EN 50363-10-2 G = with green-yellow conductor
Sheath colour yellow (RAL 1021) x = without green-yellow conductor (OB).
also available in other colours on request Art.no. 22212 = JB-version.
with meter marking Art.no. 22220 = JZ-version.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Robust control cable with an outstanding resistance to oil and abrasion. Suitable for use in tool making and machine industries, steel works, on building
sites and in the oil and coal industries. The cable can also be used for portable tools. etc. To be recommended if the cable comes into contact with
chemical agents.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22200 2 x 0,75 6,4 14,4 50,0 19 22212 4 G 1,5 9,0 58,0 135,0 16
22201 3 G 0,75 6,8 21,6 70,0 19 22220 4 G 1,5 9,7 58,0 135,0 16
22202 4 G 0,75 7,3 28,8 80,0 19 22213 5 G 1,5 11,2 72,0 158,0 16
22203 5 G 0,75 8,2 36,0 100,0 19 22214 7 G 1,5 9,2 101,0 221,0 16
22204 7 G 0,75 9,2 50,0 140,0 19 22215 2 x 2,5 9,6 48,0 150,0 14
22205 2x1 7,2 19,2 63,0 18 22216 3 G 2,5 11,0 72,0 173,0 14
22206 3G1 7,6 29,0 76,0 18 22217 4 G 2,5 12,0 96,0 203,0 14
22207 4G1 8,0 38,0 95,0 18 22218 5 G 2,5 13,7 120,0 253,0 14
22208 5G1 8,8 48,0 120,0 18 22219 7 G 2,5 9,0 168,0 356,0 14
22209 7G1 10,0 67,0 170,0 18 22221 4G4 14,6 153,6 310,0 12
22210 2 x 1,5 7,8 29,0 80,0 16 22222 5G4 14,8 192,0 370,0 12
22211 3 G 1,5 8,3 43,0 105,0 16 22233 4 G 35 33,0 1344,0 2100,0 2

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS
Cable Gland - HELUTOP HT-E

71
Flexible Control Cables / PUR Control Cables

H05BQ-F / H07BQ-F (NGMH11Y)

Technical data Cable structure Properties


EPR/PUR-insulated power cable acc. to Bare copper-conductor, to Abrasion resistant
DIN VDE 0285-525-2-21 / DIN VDE 0295 cl.5, fine-wire, Notch resistant
DIN EN 50525-2-21 BS 6360 cl.5, IEC 60228 cl.5 Resistant to tearing and cutting
Temperature range Core insulation of rubber Resistant to
flexing -40C to +80C compound type EI6 to Oils, fats, Petrol
fixed installation -50C to +90C DIN VDE 0207-363-1 / DIN EN 50363-1 Water and weathering effects
Permissible operating temperature Core identification to DIN VDE 0293-308 Oxygene and ozone
at conductor +90C GN-YE conductor, 3 cores and above UV-radiation, Hydrolysis and Microbial attack
Nominal voltage in the outer layer The materials used in manufacture are
H05BQ-F U0/U 300/500 V Cores stranded in layers with cadmium-free and contain no silicone
H07BQ-F U0/U 450/750 V optimal lay-length (inner fill compound and free from substances harmful to
Test voltage permissible *) the wetting properties of lacquers
H05BQ-F 2000 V Outer sheath of PUR
H07BQ-F 2500 V compound type TMPU to Note
Minimum bending radius DIN EN 50363-10-2 G = with green-yellow conductor
flexing 5x cable Sheath colour orange (RAL 2003) x = without green-yellow conductor
fixed installation 3x cable adapted to VDE
Radiation resistance 7G1,5 mm, 12G1,5 mm and
up to 100x106 cJ/kg (up to 100 Mrad) cross-section > 16 mm
designation 07BQ-F
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
*) Version with filler compound

Application
These cables can be used for medium mechanical loads in dry, damp or wet environments, e. g. for connecting agricultural and commercial equipment
and heaters provided there is no danger of contact with the hot parts or by radiation of heat. These robust and flexible cables are used for electrical
tools such as drills and hand-held circular saws, as well as for portable motors and machinery in agriculture, at building sites, docks and refrigeration
plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05BQ-F H07BQ-F
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. *) No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
22050 2 x 0,75 5,7 - 7,4 14,4 52,0 19 22074 220974 2 x 10 15,6 - 19,9 192,0 428,0 8
22051 3 G 0,75 6,2 - 8,1 21,6 63,0 19 22076 220976 3 G 10 16,8 - 21,4 288,0 640,0 8
22052 4 G 0,75 6,8 - 8,8 29,0 80,0 19 22078 220978 4 G 10 18,6 - 23,6 384,0 738,0 8
22053 5 G 0,75 7,6 - 9,9 36,0 96,0 19 22082 220982 5 G 10 20,4 - 25,9 480,0 968,0 8
22054 2x1 6,1 - 8,0 19,2 59,0 18 22075 220975 2 x 16 17,9 - 22,8 307,0 600,0 6
22055 3G1 6,5 - 8,5 29,0 71,0 18 22077 220977 3 G 16 19,5 - 24,7 461,0 758,0 6
22056 4G1 7,1 - 9,3 38,4 89,0 18 22079 220979 4 G 16 21,3 - 27,0 614,0 1187,0 6
22057 5G1 8,0 - 10,3 48,0 112,0 18 22083 220983 5 G 16 23,7 - 30,0 768,0 1475,0 6
22828 228928 4 G 25 26,7 - 32,6 960,0 1550,0 4
H07BQ-F 22829 228929 5 G 25 29,6 - 36,1 1220,0 1920,0 4
Part no. *) No.cores x Outer Cop. Weight AWG-No. 22830 228930 4 G 35 31,3 - 38,2 1344,0 2120,0 2
cross-sec. min. - max. weight approx. 22831 228931 5 G 35 34,5 - 42,0 1680,0 2600,0 2
mm mm kg / km kg / km 22832 228932 4 G 50 34,9 - 42,6 1920,0 2920,0 1
22058 220958 2 x 1,5 7,6 - 9,8 29,0 92,0 16 22833 228933 5 G 50 38,6 - 47,0 2400,0 3700,0 1
22059 220959 3 G 1,5 8,0 - 10,4 43,0 109,0 16 22835 228935 4 G 70 38,9 - 47,3 2688,0 3900,0 2/0
22060 220960 4 G 1,5 9,0 - 11,6 58,0 145,0 16 22836 228936 5 G 70 43,0 - 52,3 3368,0 5020,0 2/0
22061 220961 5 G 1,5 9,8 - 12,7 72,0 169,0 16 22837 228937 4 G 95 44,9 - 54,6 3648,0 5150,0 3/0
22062 220962 7 G 1,5 12,2 - 15,1 101,0 230,0 16 22838 228938 5 G 95 49,7 - 60,4 4560,0 6520,0 3/0
22063 220963 12 G 1,5 15,0 - 18,4 173,0 398,0 16 22839 228939 4 G 120 47,9 - 58,2 4608,0 6550,0 4/0
22064 220964 2 x 2,5 9,0 - 11,6 48,0 121,0 14 22840 228940 5 G 120 53,1 - 64,5 5760,0 8050,0 4/0
22065 220965 3 G 2,5 9,6 - 12,4 72,0 164,0 14 22841 228941 4 G 150 53,5 - 65,0 5760,0 7950,0 300 kcmil
22066 220966 4 G 2,5 10,7 - 13,8 96,0 207,0 14 22842 228942 5 G 185 65,6 - 79,6 7104,0 9350,0 350 kcmil
22067 220967 5 G 2,5 11,9 - 16,3 120,0 262,0 14 22843 228943 4 G 240 68,1 - 82,6 9216,0 12200,0 500 kcmil
22072 220972 2x4 10,6 - 13,7 77,0 194,0 12
22068 220968 3G4 11,3 - 14,5 115,0 224,0 12
22069 220969 4G4 12,7 - 16,2 154,0 327,0 12
22080 220980 5G4 14,1 - 17,9 192,0 415,0 12
22073 220973 2x6 11,8 - 15,1 115,0 311,0 10
22070 220970 3G6 12,8 - 16,3 173,0 310,0 10
22071 220971 4G6 14,2 - 18,1 230,0 496,0 10
22081 220981 5G6 15,7 - 20,0 288,0 586,0 10

Dimensions and specifications may be changed without prior notice. (RA02)

72
Flexible Control Cables / PUR Control Cables

UNIPUR flexible at low temperature, with customer markings, halogen-free,


wear resistant, robust, meter marking
A

Technical data Cable structure Properties


Spezial TPE/PUR connecting cable Bare copper-conductor, to Abrasion resistant, Notch resistant
adapted to DIN VDE 0285-525-2-21/ DIN VDE 0295 cl.5, fine-wire, Resistant to tearing and cutting
DIN EN 50525-2-21 BS 6360 cl.5, IEC 60228 cl.5 Good flexibility at low temperatures down
Temperature range Core insulation of termoplastic to -40C
flexing -40C to +90C elastomere (TPE) Resistant to
Nominal voltage Core identification to DIN VDE 0293-308 Oils and fats
up to 1 mm U0/U 300/500 V - up to 5 cores coloured Water and weathering effects
from 1,5 mm U0/U 450/750 V - from 6 cores, black with continuous Ozone and oxygen
Test voltage 3000 V white numbering UV-radiation
Minimum bending radius GN-YE conductor, 3 cores and above Hydrolysis
flexing 10x cable Cores stranded in layers with Microbial attack
fixed installation 5x cable optimal lay-length The materials used in manufacture are
Radiation resistance Outer sheath of PUR cadmium-free and contain no silicone
up to 100x106 cJ/kg (up to 100 Mrad) compound type TMPU adapted and free from substances harmful to
to DIN EN 50363-10-2 the wetting properties of lacquers
Sheath colour by request
with meter marking Note
G = with green-yellow conductor
x = without green-yellow conductor (OB).
Please add the individual part no.
for order with the identification
colour code:
0 = approx.RAL 5015 blue
1 = approx.RAL 6018 green
2 = approx.RAL 8003 brown
3 = approx.RAL 1021 yellow*
4 = approx.RAL 3000 red
5 = approx.RAL 2003 orange
6 = approx.RAL 4005 violet
7 = approx.RAL 7001/7032 grey
Further colours on request.
*with yellow outer sheath as storage types
VDE-Reg.No. cable with 2-7 cores
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
UNIPUR-CP, confer page 82

Application
These robust and flexible cables are used for electrical tools such as drills, hand-held circular saws, and garden equipment as well as for portable
motors and machinery in agriculture, at building sites, for hobbies, docks and refrigeration plants.
Extremely good mechanical characteristies e. g. compressive load, good abrasion and near-resistant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
1812x 2 x 0,5 5,8 9,6 40,0 20 1822x 2 x 0,75 6,3 14,0 52,0 19
1813x 3 G 0,5 6,1 14,4 47,0 20 1823x 3 G 0,75 6,9 21,6 62,0 19
1814x 4 G 0,5 6,7 19,0 57,0 20 1824x 4 G 0,75 7,5 28,8 80,0 19
1815x 5 G 0,5 7,5 24,0 65,0 20 1825x 5 G 0,75 8,3 36,0 94,0 19
1816x 7 G 0,5 9,0 33,6 94,0 20 1826x 6 G 0,75 9,0 43,0 111,0 19
1817x 12 G 0,5 10,7 58,0 150,0 20 1827x 7 G 0,75 9,8 50,0 160,0 19
1818x 18 G 0,5 13,0 86,0 208,0 20 1828x 12 G 0,75 11,6 86,0 191,0 19
1819x 25 G 0,5 15,6 120,0 276,0 20 1829x 18 G 0,75 14,1 130,0 267,0 19
1820x 34 G 0,5 17,9 163,0 393,0 20 1830x 25 G 0,75 17,0 180,0 376,0 19
1821x 41 G 0,5 19,6 197,0 460,0 20 1831x 34 G 0,75 19,5 245,0 506,0 19
1832x 41 G 0,75 21,2 296,0 596,0 19

Continuation

73
Flexible Control Cables / PUR Control Cables

UNIPUR flexible at low temperature, with customer markings, halogen-free,


wear resistant, robust, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
1833x 2x1 6,8 19,2 59,0 18 1855x 2 x 2,5 9,9 48,0 120,0 14
1834x 3G1 7,2 29,0 70,0 18 1856x 3 G 2,5 10,5 72,0 148,0 14
1835x 4G1 7,8 38,0 87,0 18 1857x 4 G 2,5 11,6 96,0 184,0 14
1836x 5G1 8,8 48,0 100,0 18 1858x 5 G 2,5 13,0 120,0 224,0 14
1837x 6G1 9,7 58,0 131,0 18 1859x 7 G 2,5 15,5 168,0 301,0 14
1838x 7G1 10,6 67,0 182,0 18 1860x 12 G 2,5 19,2 288,0 489,0 14
1839x 12 G 1 12,6 115,0 230,0 18 1861x 2x4 11,5 77,0 149,0 12
1840x 18 G 1 15,3 173,0 325,0 18 1862x 3G4 12,2 115,0 240,0 12
1841x 25 G 1 18,3 240,0 476,0 18 1863x 4G4 13,5 154,0 297,0 12
1842x 34 G 1 21,0 326,0 616,0 18 1864x 5G4 15,0 192,0 360,0 12
1843x 41 G 1 22,9 394,0 724,0 18 1865x 7G4 18,3 268,0 540,0 12
1844x 2 x 1,5 8,3 29,0 92,0 16 1866x 2x6 13,1 115,0 240,0 10
1845x 3 G 1,5 8,8 43,0 108,0 16 1867x 3G6 14,1 173,0 370,0 10
1846x 4 G 1,5 9,7 58,0 144,0 16 1868x 4G6 15,6 230,0 472,0 10
1847x 5 G 1,5 10,7 72,0 168,0 16 1869x 5G6 17,3 288,0 581,0 10
1848x 6 G 1,5 11,8 86,0 201,0 16 1870x 7G6 21,0 403,0 698,0 10
1849x 7 G 1,5 12,9 101,0 230,0 16 1871x 3 G 10 18,0 288,0 560,0 8
1850x 12 G 1,5 15,5 173,0 306,0 16 1872x 4 G 10 20,1 384,0 718,0 8
1851x 18 G 1,5 18,7 259,0 464,0 16 1873x 5 G 10 22,2 480,0 896,0 8
1852x 25 G 1,5 22,9 360,0 641,0 16 1874x 3 G 16 23,4 461,0 940,0 6
1853x 34 G 1,5 25,9 490,0 857,0 16 1875x 4 G 16 25,5 614,0 1068,0 6
1854x 41 G 1,5 28,3 590,0 1010,0 16 1876x 5 G 16 28,3 768,0 1810,0 6

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS
Cable Gland - HELUTOP HT-E

74
Flexible Control Cables / PUR Control Cables

PUR-750 halogen-free, meter marking

Technical data Cable structure Properties


Special-PUR control cable adapted Bare copper-conductor, to High flexibility at low temperature
to DIN VDE 0285-525-2-21/ DIN VDE 0295 cl.5, fine-wire, Usable for foodstuffs
DIN EN 50525-2-21 BS 6360 cl.5, IEC 60228 cl.5 High abrasion resistance
Temperature range Core insulation PUR Resistant to
flexing -40C to +80C Core identification to DIN VDE 0293-308 Oils and fats
(up to +100C for short periods) - for 2 cores, BN, BU Non-alcoholic fuels and kerosene
Nominal voltage - up to 5 cores coloured Atmospheric influences, UV-radiation
up to 1 mm U0/U 300/500 V - from 6 cores, black with continuous Oxygene and ozone
from 1,5 mm U0/U 450/750 V white numbering Microbes and rotting
Test voltage GN-YE conductor, 3 cores and above Sea and waste water
up to 1 mm 2000 V in the outer layer vibrations
from 1,5 mm 2500 V Cores stranded in layers with The materials used in manufacture are
Insulation resistance optimal lay-length cadmium-free and contain no silicone
min. 20 MOhm x km Outer sheath of halogen-free PUR and free from substances harmful to
Minimum bending radius Sheath colour orange (RAL 2004) the wetting properties of lacquers
flexing 10x cable with meter marking
fixed installation 5x cable Note
Radiation resistance G = with green-yellow conductor
up to 100x106 cJ/kg (up to 100 Mrad) x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Especially suited for installation in all areas demanding good performance under extreme conditions. These cable types have been successfully in use
in areas such as steel works, heating and air-conditioning systems, in machinery and industrial plant equipment and on building sites etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49700 2 x 0,75 6,3 15,0 44,0 19 49739 18 G 2,5 23,0 432,0 778,0 14
49701 3 G 0,75 6,8 22,0 55,0 19 49740 20 G 2,5 24,4 480,0 860,0 14
49702 4 G 0,75 7,4 29,0 70,0 19 49741 25 G 2,5 28,5 600,0 1083,0 14
49703 5 G 0,75 8,3 36,0 91,0 19 49742 3G4 12,2 115,0 220,0 12
49704 7 G 0,75 9,7 50,0 130,0 19 49743 4G4 13,4 154,0 280,0 12
49705 12 G 0,75 12,1 86,0 192,0 19 49744 5G4 15,1 192,0 350,0 12
49706 18 G 0,75 14,2 130,0 290,0 19 49745 7G4 18,2 269,0 470,0 12
49707 25 G 0,75 17,6 180,0 405,0 19 49746 4G6 15,8 230,0 400,0 10
49708 2x1 6,8 20,0 50,0 18 49747 5G6 17,3 288,0 500,0 10
49709 3G1 7,2 29,0 65,0 18 49748 7G6 21,0 403,0 700,0 10
49710 4G1 7,8 38,0 87,0 18 49749 4 G 10 20,4 384,0 640,0 8
49711 5G1 8,8 48,0 106,0 18 49750 5 G 10 22,5 480,0 800,0 8
49712 6G1 9,5 58,0 135,0 18 49751 7 G 10 26,6 672,0 1180,0 8
49713 7G1 10,4 67,0 160,0 18 49752 4 G 16 23,3 614,0 920,0 6
49714 8G1 11,4 77,0 185,0 18 49753 5 G 16 25,9 768,0 1180,0 6
49715 10 G 1 12,8 96,0 210,0 18 49754 4 G 25 27,3 960,0 1400,0 4
49716 12 G 1 12,8 115,0 240,0 18 49755 5 G 25 30,4 1200,0 1740,0 4
49717 16 G 1 14,4 154,0 310,0 18 49756 4 G 35 31,0 1344,0 1870,0 2
49718 18 G 1 15,3 173,0 353,0 18 49757 5 G 35 34,8 1680,0 2320,0 2
49719 20 G 1 16,4 192,0 390,0 18 49758 4 G 50 36,8 1920,0 2700,0 1
49720 25 G 1 18,8 240,0 495,0 18 49759 5 G 50 41,2 2400,0 3300,0 1
49721 2 x 1,5 8,2 29,0 70,0 16 49760 4 G 70 43,2 2688,0 3700,0 2/0
49722 3 G 1,5 8,7 43,0 95,0 16 49761 5 G 70 48,2 3660,0 4900,0 2/0
49723 4 G 1,5 9,7 58,0 120,0 16 49918 4 G 95 48,7 3648,0 4850,0 3/0
49724 5 G 1,5 10,6 72,0 164,0 16 49762 5 G 95 54,5 4560,0 6000,0 3/0
49725 7 G 1,5 12,8 101,0 210,0 16 49763 4 G 120 54,9 4610,0 6005,0 4/0
49726 10 G 1,5 15,8 150,0 290,0 16
49727 12 G 1,5 15,8 172,0 340,0 16
49728 16 G 1,5 17,9 230,0 440,0 16
49729 18 G 1,5 18,8 259,0 508,0 16
49730 20 G 1,5 20,0 300,0 560,0 16
49731 25 G 1,5 23,5 360,0 722,0 16
49732 2 x 2,5 9,8 48,0 110,0 14
49733 3 G 2,5 10,5 72,0 150,0 14
49734 4 G 2,5 11,6 96,0 180,0 14
49735 5 G 2,5 13,0 120,0 240,0 14
49736 7 G 2,5 15,5 168,0 340,0 14
49737 12 G 2,5 19,3 288,0 520,0 14
49738 16 G 2,5 21,6 394,0 680,0 14

Dimensions and specifications may be changed without prior notice. (RA02)

75
Flexible Control Cables / PUR Control Cables

JZ-500-FC-PUR EMC-preferred type, tear and coolant resistant, screened, without


inner sheath, meter marking

Technical data Cable structure Properties


Special-PUR control cable adapted to Bare copper-conductor, to Resistant to
DIN VDE 0285-525-1 / DIN EN 50525-1 DIN VDE 0295 cl.5, fine-wire, UV-radiation, Oxygen, Ozone,Hydrolyse
Temperature range BS 6360 cl.5, IEC 60228 cl.5 and Microbes
flexing -10C to +80C Core insulation of special PVC Low adhesion, matt surface
fixed installation -40C to +80C compound type TI2 to The materials used in manufacture are
Nominal voltage U0/U 300/500 V DIN VDE 0207-363-3 / DIN EN 50363-3 cadmium-free and contain no silicone
Test voltage 3000 V Core identification to DIN VDE 0293 and free from substances harmful to
Breakdown voltage min. 6000 V black cores with continuous white the wetting properties of lacquers
Coupling resistance numbering
max. 250 Ohm/km GN-YE conductor, 3 cores and above Note
Minimum bending radius in the outer layer G = with green-yellow conductor
flexing 10x cable Cores stranded in layers with x = without green-yellow conductor (OZ)
fixed installation 5x cable optimal lay-length AWG sizes are approximate equivalent
Radiation resistance Separating foil values. The actual cross-section is in mm.
up to 100x106 cJ/kg (up to 100 Mrad) Tinned copper braided screen, unscreened analogue type:
approx. 85% coverage JZ-500-PUR, confer page 67
Core wrapping of fleece
guarantees easy cable stripping
Outer sheath from special full polyurethane
compound type TMPU to
DIN EN 50363-10-2
Sheath colour grey (RAL 7001)
also available in other colours on request
with meter marking

Application
Extremely robust cable noted for its good abrasion resistance and notch resistance. Due to its resistance to coolant emulsions, this cable is well suited
for use in mechanical engineering, tool making, and systems engineering, and in steel mills and rolling mills in particularly critical areas. Good flexibility
means that installation is quick and easy. Suitable for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms, and in open air (fixed installation). The dense screening assures interference-free transmission of all signals and impulses.
An ideal interference-free control cable for the above applications.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
23414 2 x 0,5 5,7 35,0 47,0 20 23429 2 x 0,75 6,1 40,0 60,0 19
23415 3 G 0,5 5,9 42,0 57,0 20 23430 3 G 0,75 6,3 52,0 67,0 19
23416 3 x 0,5 5,9 42,0 57,0 20 23431 3 x 0,75 6,3 52,0 67,0 19
23417 4 G 0,5 6,4 47,0 60,0 20 23432 4 G 0,75 6,8 60,0 76,0 19
23418 4 x 0,5 6,4 47,0 60,0 20 23433 4 x 0,75 6,8 60,0 76,0 19
23419 5 G 0,5 6,9 56,0 75,0 20 23435 5 x 0,75 7,4 71,0 92,0 19
23420 5 x 0,5 6,9 56,0 75,0 20 23434 5 G 0,75 7,4 71,0 92,0 19
23421 7 G 0,5 7,6 69,0 97,0 20 23437 7 x 0,75 8,2 91,0 131,0 19
23422 7 x 0,5 7,6 69,0 97,0 20 23436 7 G 0,75 8,2 91,0 131,0 19
23423 10 G 0,5 9,6 94,0 133,0 20 23438 10 G 0,75 10,3 137,0 180,0 19
23424 12 G 0,5 9,7 108,0 158,0 20 23439 12 G 0,75 10,5 142,0 204,0 19
23425 18 G 0,5 11,5 145,0 218,0 20 23440 18 G 0,75 12,7 212,0 290,0 19
23426 25 G 0,5 13,7 240,0 315,0 20 23441 25 G 0,75 15,0 281,0 413,0 19
23427 34 G 0,5 15,5 312,0 420,0 20 23442 34 G 0,75 17,2 345,0 492,0 19
23428 42 G 0,5 16,9 355,0 487,0 20 23443 42 G 0,75 18,8 407,0 624,0 19

Continuation

76
Flexible Control Cables / PUR Control Cables

JZ-500-FC-PUR EMC-preferred type, tear and coolant resistant, screened, without


inner sheath, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
23444 2x1 6,4 50,0 66,0 18 23473 2 x 2,5 8,4 96,0 131,0 14
23445 3G1 6,7 60,0 82,0 18 23474 3 G 2,5 8,8 144,0 168,0 14
23446 3x1 6,7 60,0 82,0 18 23475 4 G 2,5 9,8 148,0 194,0 14
23447 4G1 7,2 71,0 100,0 18 23476 5 G 2,5 10,8 181,0 222,0 14
23448 4x1 7,2 71,0 100,0 18 23477 7 G 2,5 11,9 255,0 345,0 14
23449 5G1 8,0 88,0 128,0 18 23478 12 G 2,5 15,8 441,0 570,0 14
23450 5x1 8,0 88,0 128,0 18 23479 4G4 11,6 230,0 310,0 12
23451 7G1 8,7 111,0 157,0 18 23480 5G4 12,9 273,0 386,0 12
23452 7x1 8,7 111,0 157,0 18 23481 7G4 14,2 316,0 498,0 12
23453 10 G 1 11,2 150,0 230,0 18 23482 4G6 13,8 305,0 414,0 10
23454 12 G 1 11,4 184,0 262,0 18 23483 5G6 15,4 439,0 510,0 10
23455 18 G 1 13,6 260,0 381,0 18 23484 7G6 17,0 505,0 673,0 10
23456 25 G 1 16,2 349,0 535,0 18 23485 4 G 10 17,2 535,0 591,0 8
23457 34 G 1 18,5 486,0 740,0 18 23486 5 G 10 19,1 592,0 768,0 8
23458 42 G 1 20,2 545,0 867,0 18 23487 7 G 10 21,2 810,0 976,0 8
23459 50 G 1 22,0 625,0 1027,0 18 23488 4 G 16 20,3 740,0 1196,0 6
23460 2 x 1,5 7,0 63,0 87,0 16
23461 3 G 1,5 7,4 80,0 102,0 16
23462 3 x 1,5 7,4 80,0 102,0 16
23463 4 G 1,5 8,1 97,0 127,0 16
23464 4 x 1,5 8,1 97,0 127,0 16
23465 5 G 1,5 9,0 119,0 159,0 16
23466 5 x 1,5 9,0 119,0 159,0 16
23467 7 G 1,5 9,8 147,0 207,0 16
23468 7 x 1,5 9,8 147,0 207,0 16
23469 12 G 1,5 12,8 267,0 340,0 16
23470 18 G 1,5 15,6 374,0 480,0 16
23471 25 G 1,5 18,4 526,0 704,0 16
23472 30 G 1,5 19,6 555,0 817,0 16

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS
Cable Gland - HELUTOP HT-E

77
Flexible Control Cables / PUR Control Cables

F-C-PUR-JZ tear and coolant resistant, Cu-screened, without inner sheath, increased
oil resistant, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special-PUR control cable adapted to Bare copper-conductor, to Resistant to
DIN VDE 0285-525-1 / DIN EN 50525-1 DIN VDE 0295 cl.5, fine-wire, UV-Radiation
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Oxygene
flexing -20C to +80C Core insulation of oil resistant PVC Ozone
fixed installation -40C to +80C compound type TI2 adapted to Hydrolysis
Nominal voltage U0/U 300/500 V DIN VDE 0207-363-3 / DIN EN 50363-3 Microbes
Test voltage 3000 V for better sliding abilities The materials used in manufacture are
Breakdown voltage min. 6000 V Core identification to DIN VDE 0293 cadmium-free and contain no silicone
Coupling resistance black cores with continuous white and free from substances harmful to
max. 250 Ohm/km numbering the wetting properties of lacquers
Minimum bending radius GN-YE conductor, 3 cores and above
flexing 10x cable in the outer layer Note
fixed installation 5x cable Cores stranded in layers with G = with green-yellow conductor
Radiation resistance optimal lay-length x = without green-yellow conductor (OZ)
up to 100x106 cJ/kg (up to 100 Mrad) Separating foil AWG sizes are approximate equivalent
Tinned copper braided screen, values. The actual cross-section is in mm.
approx. 85% coverage unscreened analogue type:
Core wrapping of fleece PUR-JZ, confer page 68
guarantees easy cable stripping
Outer sheath of special full-polyurethane
compound type TMPU to
DIN EN 50363-10-2
Sheath colour grey (RAL 7001)
also available in other colours on request
with meter marking

Application
Extremely robust control cable characterised by high abrasion and notch resistance properties. Used for critical areas in such applications as machinery,
tooling and plant construction, in rolling mills and steel works because of the resistance to mineral oils and to coolant emulsions in particular. Rapid
and safe installation assured by the good flexibility of the cable. Suitable for outdoor installation.
An interference-free transmission of signals and pulses is assured by the high screening density. The ideal interference-protected control cable for
such applications as given above.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21200 2 x 0,5 5,7 35,0 44,0 20 21227 2 x 0,75 6,1 40,0 60,0 19
21201 3 G 0,5 5,9 42,0 56,0 20 21228 3 G 0,75 6,3 52,0 67,0 19
21202 4 G 0,5 6,4 47,0 60,0 20 21229 4 G 0,75 6,8 60,0 76,0 19
21203 5 G 0,5 6,9 56,0 75,0 20 21230 5 G 0,75 7,4 71,0 92,0 19
21205 7 G 0,5 7,6 69,0 97,0 20 21232 7 G 0,75 8,2 91,0 131,0 19
21207 10 G 0,5 9,6 94,0 133,0 20 21234 10 G 0,75 10,3 137,0 180,0 19
21208 12 G 0,5 9,7 108,0 158,0 20 21235 12 G 0,75 10,5 142,0 204,0 19
21209 14 G 0,5 10,2 116,0 190,0 20 21236 14 G 0,75 11,3 180,0 226,0 19
21211 18 G 0,5 11,5 145,0 218,0 20 21238 18 G 0,75 12,7 212,0 290,0 19
21213 21 G 0,5 12,3 188,0 252,0 20 21240 21 G 0,75 13,6 246,0 376,0 19
21215 25 G 0,5 13,7 240,0 315,0 20 21242 25 G 0,75 15,0 281,0 413,0 19
21217 30 G 0,5 14,4 295,0 362,0 20 21245 32 G 0,75 16,7 342,0 485,0 19
21220 36 G 0,5 15,6 318,0 447,0 20 21249 41 G 0,75 18,2 400,0 611,0 19
21221 40 G 0,5 16,4 343,0 475,0 20 21251 50 G 0,75 20,3 461,0 775,0 19
21224 50 G 0,5 18,5 406,0 572,0 20

Continuation

78
Flexible Control Cables / PUR Control Cables

F-C-PUR-JZ tear and coolant resistant, Cu-screened, without inner sheath, increased
oil resistant, EMC-preferred type, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21253 2x1 6,4 50,0 66,0 18 21290 14 G 1,5 13,5 283,0 384,0 16
21254 3G1 6,7 60,0 82,0 18 21291 16 G 1,5 14,6 315,0 425,0 16
21255 4G1 7,2 71,0 100,0 18 21292 18 G 1,5 15,6 374,0 480,0 16
21256 5G1 8,0 88,0 128,0 18 21295 21 G 1,5 16,6 425,0 563,0 16
21257 6G1 8,7 97,0 145,0 18 21296 25 G 1,5 18,5 526,0 704,0 16
21258 7G1 8,7 111,0 157,0 18 21297 34 G 1,5 21,2 629,0 870,0 16
21259 8G1 9,6 127,0 198,0 18 21298 42 G 1,5 22,2 819,0 1040,0 16
21261 10 G 1 11,2 150,0 230,0 18 21299 50 G 1,5 25,0 885,0 1292,0 16
21262 12 G 1 11,4 184,0 262,0 18 21300 2 x 2,5 8,4 96,0 131,0 14
21263 14 G 1 12,0 196,0 302,0 18 21301 3 G 2,5 8,8 144,0 168,0 14
21264 16 G 1 12,8 209,0 345,0 18 21302 4 G 2,5 9,8 148,0 194,0 14
21265 18 G 1 13,6 260,0 381,0 18 21303 5 G 2,5 10,8 181,0 222,0 14
21267 21 G 1 14,3 319,0 480,0 18 21304 7 G 2,5 11,9 255,0 345,0 14
21268 25 G 1 16,2 349,0 535,0 18 21305 10 G 2,5 15,5 340,0 462,0 14
21273 34 G 1 18,5 486,0 740,0 18 21306 12 G 2,5 15,8 441,0 570,0 14
21276 41 G 1 19,5 531,0 855,0 18 21313 2x4 10,0 120,0 187,0 12
21278 50 G 1 22,0 625,0 1027,0 18 21314 3G4 10,6 174,0 243,0 12
21280 2 x 1,5 7,0 63,0 87,0 16 21315 4G4 11,6 230,0 310,0 12
21281 3 G 1,5 7,4 80,0 102,0 16 21316 5G4 12,8 273,0 386,0 12
21282 4 G 1,5 8,1 97,0 127,0 16 21317 7G4 14,2 316,0 498,0 12
21283 5 G 1,5 9,0 119,0 159,0 16 21319 3G6 12,5 240,0 333,0 10
21285 7 G 1,5 9,8 147,0 207,0 16 21320 4G6 13,8 305,0 414,0 10
21286 8 G 1,5 10,8 170,0 245,0 16 21321 5G6 15,4 439,0 510,0 10
21287 10 G 1,5 12,6 193,0 313,0 16 21322 7G6 17,0 505,0 673,0 10
21288 12 G 1,5 12,8 267,0 340,0 16

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

79
Flexible Control Cables / PUR Control Cables

Y-C-PUR-JZ tear and coolant resistant, Cu-screened, with inner sheath, increased
oil resistant, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special-PUR sheathed multicore cable Bare copper-conductor, to Resistant to
adapted to DIN VDE 0285-525-1 / DIN VDE 0295 cl.5, fine-wire, UV-Radiation
DIN EN 50525-1 BS 6360 cl.5, IEC 60228 cl.5 Oxygene
Temperature range Outer sheath of oil resistant PVC Ozone
flexing -20C to +80C compound type TI2 adapted to Hydrolysis
fixed installation -40C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 Microbes
Nominal voltage for better sliding abilities The materials used in manufacture are
up to 2,5 mm U0/U 300/500 V Core identification to DIN VDE 0293 cadmium-free and contain no silicone
from 4 mm U0/U 450/750 V black cores with continuous white and free from substances harmful to
Test voltage 4000 V numbering the wetting properties of lacquers
Breakdown voltage min. 8000 V GN-YE conductor, 3 cores and above
Coupling resistance in the outer layer Note
max. 250 Ohm/km Cores stranded in layers with G = with green-yellow conductor
Minimum bending radius optimal lay-length x = without green-yellow conductor (OZ)
flexing 10x cable Inner sheath of oil resistant PVC AWG sizes are approximate equivalent
fixed installation 5x cable Tinned copper braided screen, values. The actual cross-section is in mm.
Radiation resistance approx. 85% coverage unscreened analogue type:
up to 100x106 cJ/kg (up to 100 Mrad) Core wrapping of fleece PUR-JZ, confer page 68
guarantees easy cable stripping
Outer sheath of special full-polyurethane
compound type TMPU to
DIN EN 50363-10-2
Sheath colour grey (RAL 7001)
with meter marking

Application
Extremely robust control cable characterised by high abrasion and notch resistance properties. Used for critical areas in such applications as machinery,
tooling and plant construction, in rolling mills and steel works because of the resistance to mineral oils and to coolant emulsions in particular. The
mechanical strength of the cable is increased by the additional oil-resistant inner sheath. The ideal interference-protected control cable for such
applications as given above. Suitable for outdoor installation.
These screened cables are particularly suitable for the interference-free transmission in instrumentation and control engineering applications
(electromagnetic compatibillity).
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21400 2 x 0,5 7,0 41,0 68,0 20 21425 2 x 0,75 7,7 46,0 88,0 19
21401 3 G 0,5 7,3 45,0 84,0 20 21426 3 G 0,75 8,0 57,0 98,0 19
21402 4 G 0,5 7,9 54,0 95,0 20 21427 4 G 0,75 8,5 63,0 112,0 19
21403 5 G 0,5 8,4 66,0 107,0 20 21428 5 G 0,75 9,3 76,0 130,0 19
21405 7 G 0,5 9,1 79,0 135,0 20 21430 7 G 0,75 9,9 100,0 185,0 19
21407 10 G 0,5 10,7 107,0 170,0 20 21432 10 G 0,75 11,8 140,0 270,0 19
21408 12 G 0,5 11,5 137,0 195,0 20 21433 12 G 0,75 12,7 175,0 294,0 19
21409 14 G 0,5 12,2 142,0 222,0 20 21434 14 G 0,75 13,3 190,0 317,0 19
21411 18 G 0,5 13,5 156,0 278,0 20 21436 18 G 0,75 14,9 240,0 357,0 19
21413 21 G 0,5 14,2 189,0 330,0 20 21438 21 G 0,75 15,4 274,0 455,0 19
21415 25 G 0,5 15,7 250,0 406,0 20 21440 25 G 0,75 17,5 306,0 510,0 19
21416 30 G 0,5 16,2 297,0 520,0 20 21443 32 G 0,75 18,9 349,0 688,0 19
21419 36 G 0,5 17,7 320,0 587,0 20 21446 41 G 0,75 21,0 403,0 951,0 19
21420 40 G 0,5 18,4 345,0 655,0 20 21447 50 G 0,75 23,1 470,0 1100,0 19
21421 50 G 0,5 20,7 407,0 742,0 20

Continuation

80
Flexible Control Cables / PUR Control Cables

Y-C-PUR-JZ tear and coolant resistant, Cu-screened, with inner sheath, increased
oil resistant, EMC-preferred type, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21451 2x1 8,0 54,0 98,0 18 21507 2x4 13,3 124,0 300,0 12
21452 3G1 8,3 64,0 102,0 18 21508 3G4 14,0 178,0 340,0 12
21453 4G1 9,0 76,0 145,0 18 21509 4G4 15,3 234,0 408,0 12
21454 5G1 9,7 89,0 170,0 18 21510 5G4 16,7 284,0 504,0 12
21456 7G1 10,3 114,0 220,0 18 21511 7G4 18,4 321,0 640,0 12
21457 8G1 11,2 130,0 270,0 18 21512 3G6 15,6 245,0 453,0 10
21458 10 G 1 12,6 156,0 330,0 18 21513 4G6 17,0 316,0 560,0 10
21459 12 G 1 13,3 186,0 350,0 18 21514 5G6 18,6 442,0 700,0 10
21460 14 G 1 14,1 198,0 402,0 18 21515 7G6 20,4 530,0 905,0 10
21461 16 G 1 14,8 214,0 420,0 18 21516 3 G 10 19,0 367,0 750,0 8
21462 18 G 1 15,6 284,0 515,0 18 21517 4 G 10 21,1 549,0 1023,0 8
21463 20 G 1 16,4 325,0 545,0 18 21518 5 G 10 23,1 604,0 1114,0 8
21465 25 G 1 18,5 387,0 690,0 18 21519 7 G 10 25,6 820,0 1505,0 8
21468 34 G 1 20,9 500,0 912,0 18 21521 4 G 16 25,3 807,0 1385,0 6
21469 41 G 1 21,5 578,0 1070,0 18 21522 5 G 16 28,0 940,0 1550,0 6
21470 50 G 1 24,8 681,0 1318,0 18 21524 4 G 25 31,1 1169,0 1894,0 4
21474 2 x 1,5 8,6 64,0 130,0 16 21525 5 G 25 34,3 1420,0 2272,0 4
21475 3 G 1,5 9,2 82,0 152,0 16 21526 4 G 35 33,9 1680,0 2395,0 2
21476 4 G 1,5 9,8 99,0 167,0 16 21527 5 G 35 37,8 2020,0 2890,0 2
21477 5 G 1,5 10,8 123,0 203,0 16 21528 4 G 50 40,1 2370,0 3312,0 1
21479 7 G 1,5 11,7 148,0 305,0 16 21529 5 G 50 45,0 2880,0 4100,0 1
21480 8 G 1,5 12,6 172,0 335,0 16 21530 4 G 70 46,0 3257,0 4605,0 2/0
21481 10 G 1,5 14,2 198,0 422,0 16 21531 5 G 70 50,6 4032,0 5710,0 2/0
21482 12 G 1,5 14,9 274,0 435,0 16 21532 4 G 95 51,2 4060,0 6055,0 3/0
21483 14 G 1,5 15,8 294,0 480,0 16 21533 5 G 95 56,5 5244,0 7520,0 3/0
21484 16 G 1,5 16,7 318,0 525,0 16 21534 4 G 120 56,3 5231,0 7318,0 4/0
21485 18 G 1,5 17,4 386,0 642,0 16
21487 21 G 1,5 18,5 447,0 722,0 16
21489 25 G 1,5 20,8 531,0 803,0 16
21492 34 G 1,5 23,2 671,0 1068,0 16
21494 42 G 1,5 25,0 890,0 1370,0 16
21495 50 G 1,5 27,4 997,0 1677,0 16
21499 2 x 2,5 10,1 110,0 180,0 14
21500 3 G 2,5 10,8 148,0 215,0 14
21501 4 G 2,5 11,5 169,0 268,0 14
21502 5 G 2,5 12,8 220,0 349,0 14
21503 7 G 2,5 14,0 284,0 406,0 14
21504 12 G 2,5 17,9 470,0 720,0 14

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

81
Flexible Control Cables / PUR Control Cables

UNIPUR-CP flexible at low temperature, with customer markings, halogen-free,


wear resistant, robust, screened, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special TPE/PUR screened Bare copper-conductor, to Resistant to
connecting cable adapted to DIN VDE 0295 cl.5, fine-wire, Oils and fats
DIN VDE 0285-525-2-21 / BS 6360 cl.5, IEC 60228 cl.5 Water and weathering effects
DIN EN 50525-2-21 Core insulation of termoplastic Ozone and oxygen
Temperature range elastomere (TPE) UV-radiation
flexing-40C to +90C Core identification to DIN VDE 0293-308 Hydrolysis
Nominal voltage - up to 5 cores coloured Microbial attack
up to 1 mm U0/U 300/500 V - from 6 cores, black with continuous Abrasion resistant
from 1,5 mm U0/U 450/750 V white numbering Notch resistant
Test voltage 3000 V GN-YE conductor, 3 cores and above Resistant to tearing and cutting
Coupling resistance in the outer layer Good flexibility at low temperatures down
max. 250 Ohm/km Cores stranded in layers with to -40C
Minimum bending radius optimal lay-length The materials used in manufacture are
flexing 12,5x cable Separating foil cadmium-free and contain no silicone
fixed installation 7,5x cable Tinned copper braided screen, and free from substances harmful to
Radiation resistance approx. 85% coverage the wetting properties of lacquers
up to 100x106 cJ/kg (up to 100 Mrad) Outer sheath of PUR
compound type TMPU adapted Note
to DIN EN 50363-10-2 G = with green-yellow conductor
Sheath colour by request x = without green-yellow conductor (OB).
with meter marking Please complete the part number for
these cables by adding the suffix for
the colour required as per the list:
0 = approx.RAL 5015, blue
1 = approx.RAL 6018, green
2 = approx.RAL 8003, brown
3 = approx.RAL 1021, yellow
4 = approx.RAL 3000, red
5 = approx.RAL 2003, orange
6 = approx.RAL 4005, violet
7 = approx.RAL 7001/7032, grey
Further colours on request.
unscreened analogue type:
UNIPUR, confer page 73

Application
These robust and flexible cables are used for electrical tools such as drills, hand-held circular saws, and garden equipment as well as for portable
motors and machinery in agriculture, at building sites, for hobbies, docks and refrigeration plants.
Extremely good mechanical characteristies e. g. compressive load, good abrasion and near-resistant.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
1915x 2 x 0,5 6,4 35,0 46,0 20 1925x 2 x 0,75 6,8 40,0 60,0 19
1916x 3 G 0,5 6,8 42,0 56,0 20 1926x 3 G 0,75 7,1 52,0 68,0 19
1917x 4 G 0,5 7,3 47,0 62,0 20 1927x 4 G 0,75 7,7 60,0 78,0 19
1918x 5 G 0,5 7,9 56,0 75,0 20 1928x 5 G 0,75 8,6 71,0 95,0 19
1919x 7 G 0,5 9,4 69,0 98,0 20 1929x 6 G 0,75 9,3 80,0 112,0 19
1920x 12 G 0,5 11,3 108,0 158,0 20 1930x 7 G 0,75 10,3 91,0 138,0 19
1921x 18 G 0,5 13,7 145,0 216,0 20 1931x 12 G 0,75 12,5 142,0 207,0 19
1922x 25 G 0,5 16,3 240,0 315,0 20 1932x 18 G 0,75 14,8 212,0 293,0 19
1923x 34 G 0,5 18,6 312,0 371,0 20 1933x 25 G 0,75 17,9 281,0 413,0 19
1924x 41 G 0,5 20,4 348,0 442,0 20 1934x 34 G 0,75 20,3 345,0 523,0 19
1935x 41 G 0,75 22,1 400,0 609,0 19

Continuation

82
Flexible Control Cables / PUR Control Cables

UNIPUR-CP flexible at low temperature, with customer markings, halogen-free,


wear resistant, robust, screened, EMC-preferred type, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
1936x 2x1 7,2 50,0 65,0 18 1958x 2 x 2,5 10,2 96,0 129,0 14
1937x 3G1 7,6 60,0 76,0 18 1959x 3 G 2,5 10,9 144,0 158,0 14
1938x 4G1 8,4 71,0 89,0 18 1960x 4 G 2,5 11,9 148,0 196,0 14
1939x 5G1 9,2 88,0 108,0 18 1961x 5 G 2,5 13,2 181,0 241,0 14
1940x 6G1 10,1 97,0 141,0 18 1962x 7 G 2,5 16,3 255,0 317,0 14
1941x 7G1 11,2 111,0 187,0 18 1963x 12 G 2,5 20,0 441,0 496,0 14
1942x 12 G 1 13,5 184,0 240,0 18 1964x 2x4 11,8 120,0 158,0 12
1943x 18 G 1 16,1 260,0 335,0 18 1965x 3G4 12,7 174,0 261,0 12
1944x 25 G 1 19,4 349,0 484,0 18 1966x 4G4 14,2 230,0 316,0 12
1945x 34 G 1 22,2 486,0 627,0 18 1967x 5G4 15,7 273,0 384,0 12
1946x 41 G 1 24,0 531,0 738,0 18 1968x 7G4 19,3 316,0 592,0 12
1947x 2 x 1,5 8,6 63,0 97,0 16 1969x 2x6 13,6 173,0 259,0 10
1948x 3 G 1,5 9,1 80,0 119,0 16 1970x 3G6 14,6 240,0 394,0 10
1949x 4 G 1,5 10,1 97,0 152,0 16 1971x 4G6 16,1 305,0 483,0 10
1950x 5 G 1,5 11,2 119,0 168,0 16 1972x 5G6 18,0 439,0 592,0 10
1951x 6 G 1,5 12,1 121,0 218,0 16 1973x 7G6 21,8 505,0 714,0 10
1952x 7 G 1,5 13,6 147,0 243,0 16 1974x 3 G 10 18,0 350,0 576,0 8
1953x 12 G 1,5 16,3 267,0 317,0 16 1975x 4 G 10 19,9 535,0 729,0 8
1954x 18 G 1,5 19,6 374,0 481,0 16 1976x 5 G 10 22,2 592,0 914,0 8
1955x 25 G 1,5 23,8 526,0 674,0 16 1977x 3 G 16 20,8 585,0 960,0 6
1956x 34 G 1,5 27,0 629,0 881,0 16 1978x 4 G 16 23,1 740,0 1813,0 6
1957x 41 G 1,5 29,3 801,0 1027,0 16 1979x 5 G 16 25,5 895,0 1827,0 6

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

83
Flexible Control Cables / PUR Control Cables

PUR-C-PUR Cu-screened, extrem conditions, halogen-free, EMC-preferred type,


meter marking

Technical data Cable structure Properties


Special PUR control cables, screened, Bare copper-conductor, to High flexibility at low temperatures
adapted to DIN VDE 0250 DIN VDE 0295 cl.5, fine-wire, High abrasion resistance
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Break and cut resistant
-40C to +80C Aderisolatio aus special PUR Tear resistant
Nominal voltage Core identification to DIN VDE 0293-308 Halogen-free
up to 1 mm U0/U 300/500 V GN-YE conductor, 3 cores and above Resistant to
from 1,5 mm U0/U 450/750 V Cores stranded in layers with Oils and fats
Test voltage optimal lay-length Coolant and chemicals
to 1 mm 2000 V Core wrapping with foil Non-alcoholic fuels and kerosene
from 1,5 mm 2500 V Tinned copper braided screen, Atmospheric influences
Insulation resistance approx. 85% coverage UV-radiation
min. 20 MOhm x km PUR outer sheath Oxygene and ozone
Mutual capacitance(800 Hz) Sheath colour grey (RAL 7032) Microbes and rotting
core/core approx. 150 pF/m with meter marking Sea and waste water
core/screen approx. 320 pF/m Vibrations
Coupling resistance Acids and Lyes
max. 250 Ohm/km The materials used in manufacture are
Minimum bending radius cadmium-free and contain no silicone
flexing 10x cable and free from substances harmful to
fixed installation 5x cable the wetting properties of lacquers
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad) Note
G = with green-yellow conductor
x = without green-yellow conductor (O).
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
PUR-C-PUR screened cables are well suited as data transfer and connection cables for the machine and motor industries due to the good level of
copper screening which blocks strong electrical disturbances.
This cable type has proven to be especially suited to use in extreme weather and environmental conditions due to its good thermal and chemical
properties (Temperature range -40C to +80C). In addition to this it also possesses excellent mechanical properties, e. g. pressure resistance and
good abrasive resistant qualities, all of which go to guarantee a long life.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22315 2 x 0,75 6,8 40,0 65,0 19 22364 2 x 1,5 8,6 63,0 101,0 16
22316 3 G 0,75 7,2 52,0 80,0 19 22365 3 G 1,5 9,3 80,0 125,0 16
22317 4 G 0,75 8,0 60,0 95,0 19 22366 4 G 1,5 10,1 97,0 150,0 16
22318 5 G 0,75 8,6 71,0 126,0 19 22367 5 G 1,5 11,2 119,0 210,0 16
22319 6 G 0,75 9,5 80,0 150,0 19 22385 2 x 2,5 10,4 96,0 142,0 14
22339 2x1 7,2 50,0 80,0 18 22386 3 G 2,5 11,0 144,0 169,0 14
22340 3G1 7,8 60,0 95,0 18 22387 4 G 2,5 12,2 148,0 225,0 14
22341 4G1 8,4 71,0 106,0 18 22388 5 G 2,5 13,6 181,0 275,0 14
22342 5G1 9,5 88,0 149,0 18

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

84
HALOGEN-FREE CONTROL CABLES
Flexible Control Cables / Halogen-free Control Cables

JZ-500 HMH flexible control cable, halogen-free, extremely fire resistant,


oil resistant , meter marking
1)

Technical data Cable structure Properties


Halogen-free flexible control cable Bare copper-conductor, to ) For the critical applications we advise
adapted to DIN VDE 0295 cl.5, fine-wire, for consultation
DIN VDE 0285-525-2-51 / BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
DIN EN 50525-2-51 and Core insulation of halogen-free polymer cadmium-free and contain no silicone
DIN VDE 0285-525-3-11 / compound type TI6 to and free from substances harmful to
DIN EN 50525-3-11 DIN VDE 0207-363-7 / DIN EN 50363-7 the wetting properties of lacquers
Temperature range Core identification to DIN VDE 0293 Tests
flexing -15C to +70C black cores with continuous white Flame test acc. to
fixed installation -40C to +70C numbering DIN VDE 0482-332-3, BS 4066 part 3,
Nominal voltage U0/U 300/500 V GN-YE conductor, 3 cores and above DIN EN 60332-3, IEC 60332-3 (previously
Test voltage 2000 V in the outer layer DIN VDE 0472 part 804 test method C)
Minimum bending radius Cores stranded in layers with self-extinguishing and flame retardant
flexing 12,5x cable optimal lay-length acc. to DIN VDE 0482-332-1-2,
fixed installation 4x cable Outer sheath of halogen-free polymer DIN EN 60332-1-2, IEC 60332-1 (equivalent
Radiation resistance compound type TM7 to DIN VDE 0472 part 804 test method B)
up to 100x106 cJ/kg (up to 100 Mrad) DIN VDE 0207-363-8 / DIN EN 50363-8 Corrosiveness of combustion gases
Outer Sheath colour grey (RAL 7001) acc. to DIN VDE 0482 part 267,
with meter marking DIN EN 50267-2-2, IEC 60754-2
LS0H= Low Smoke Zero Halogen (equivalent DIN VDE 0472 part 813)
Halogen-free acc. to DIN VDE 0482
part 267, DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification when
ordering.
screened analogue type:
JZ-500 HMH-C, confer page 96

Application
Used as measuring, monitoring and control cables in tool machinery, conveyor belts, production lines, in plant, in air-conditioning, in foundries and
steel mills. For fixed installation or flexible application, casual, not constantly recurring free movement without forced motion and without tensile
stress, for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11201 2 x 0,5 4,8 9,6 43,0 20 11210 18 G 0,5 10,7 86,0 204,0 20
11202 3 G 0,5 5,1 14,4 50,0 20 11211 20 G 0,5 11,3 96,0 227,0 20
11332 3 x 0,5 5,1 14,4 50,0 20 11212 25 G 0,5 12,6 120,0 283,0 20
11203 4 G 0,5 5,6 19,0 60,0 20 11213 30 G 0,5 13,5 144,0 324,0 20
11333 4 x 0,5 5,5 19,0 60,0 20 11214 34 G 0,5 14,3 163,0 367,0 20
11204 5 G 0,5 6,2 24,0 71,0 20 11215 37 G 0,5 14,5 178,0 381,0 20
11334 5 x 0,5 6,2 24,0 71,0 20 11216 41 G 0,5 15,8 197,0 417,0 20
11205 7 G 0,5 6,7 33,6 84,0 20 11217 42 G 0,5 15,8 202,0 454,0 20
11206 8 G 0,5 7,4 38,0 101,0 20 11218 50 G 0,5 17,5 240,0 519,0 20
11207 10 G 0,5 8,3 48,0 121,0 20 11219 61 G 0,5 18,5 293,0 635,0 20
11208 12 G 0,5 8,7 58,0 142,0 20 11220 65 G 0,5 19,4 312,0 694,0 20
11209 16 G 0,5 10,0 76,0 183,0 20

Continuation

86
Flexible Control Cables / Halogen-free Control Cables

JZ-500 HMH flexible control cable, halogen-free, extremely fire resistant,


oil resistant , meter marking
1)

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11221 2 x 0,75 5,3 14,4 47,0 19 11277 2 x 2,5 7,8 48,0 118,0 14
11222 3 G 0,75 5,6 21,6 56,0 19 11278 3 G 2,5 8,3 72,0 151,0 14
11335 3 x 0,75 5,6 21,6 56,0 19 11279 4 G 2,5 9,2 96,0 181,0 14
11223 4 G 0,75 6,3 29,0 69,0 19 11280 5 G 2,5 10,1 120,0 224,0 14
11336 4 x 0,75 6,3 29,0 69,0 19 11281 7 G 2,5 11,2 168,0 316,0 14
11224 5 G 0,75 6,9 36,0 83,0 19 11282 8 G 2,5 12,3 192,0 370,0 14
11337 5 x 0,75 6,9 36,0 83,0 19 11283 10 G 2,5 14,0 240,0 451,0 14
11225 7 G 0,75 7,5 50,0 114,0 19 11284 12 G 2,5 14,8 288,0 499,0 14
11338 7 x 0,75 7,5 50,0 114,0 19 11285 16 G 2,5 17,1 384,0 720,0 14
11226 8 G 0,75 8,3 58,0 136,0 19 11286 18 G 2,5 18,2 432,0 769,0 14
11227 10 G 0,75 9,2 72,0 172,0 19 11287 20 G 2,5 19,2 480,0 911,0 14
11228 12 G 0,75 9,8 86,0 183,0 19 11288 25 G 2,5 21,6 600,0 1047,0 14
11229 16 G 0,75 11,4 115,0 241,0 19 11289 30 G 2,5 23,0 720,0 1280,0 14
11230 18 G 0,75 12,2 130,0 266,0 19 11290 2x4 9,3 77,0 199,0 12
11231 20 G 0,75 12,7 144,0 291,0 19 11291 3G4 9,8 115,0 247,0 12
11232 25 G 0,75 14,3 180,0 374,0 19 11292 4G4 10,9 154,0 299,0 12
11233 30 G 0,75 15,3 216,0 450,0 19 11293 5G4 12,1 192,0 369,0 12
11234 34 G 0,75 16,5 245,0 517,0 19 11294 7G4 13,2 269,0 463,0 12
11235 37 G 0,75 16,7 260,0 541,0 19 11295 8G4 14,7 307,0 601,0 12
11236 41 G 0,75 18,1 296,0 611,0 19 11296 10 G 4 17,5 384,0 698,0 12
11237 42 G 0,75 18,1 302,0 621,0 19 11297 12 G 4 17,7 461,0 790,0 12
11238 50 G 0,75 19,8 360,0 742,0 19 11298 16 G 4 20,3 614,0 1130,0 12
11239 61 G 0,75 21,2 439,0 853,0 19 11299 18 G 4 21,6 691,0 1280,0 12
11240 65 G 0,75 21,8 468,0 909,0 19 11300 2x6 11,0 115,0 266,0 10
11241 2x1 5,6 19,2 63,0 18 11301 3G6 11,9 173,0 360,0 10
11242 3G1 5,9 29,0 74,0 18 11302 4G6 13,0 230,0 429,0 10
11339 3x1 5,9 29,0 74,0 18 11303 5G6 14,5 288,0 529,0 10
11243 4G1 6,6 38,4 90,0 18 11304 7G6 16,2 403,0 631,0 10
11340 4x1 6,6 38,4 90,0 18 11305 2 x 10 13,8 192,0 440,0 8
11244 5G1 7,3 48,0 109,0 18 11306 3 G 10 14,9 288,0 550,0 8
11245 7G1 8,1 67,0 151,0 18 11307 4 G 10 16,5 384,0 708,0 8
11246 8G1 8,8 77,0 184,0 18 11308 5 G 10 18,3 480,0 862,0 8
11247 10 G 1 9,8 96,0 224,0 18 11309 7 G 10 20,2 672,0 1124,0 8
11248 12 G 1 10,4 115,0 243,0 18 11310 2 x 16 16,8 307,0 642,0 6
11249 16 G 1 12,3 154,0 314,0 18 11311 3 G 16 18,3 461,0 830,0 6
11250 18 G 1 12,9 173,0 361,0 18 11312 4 G 16 20,1 614,0 1060,0 6
11251 20 G 1 13,8 192,0 387,0 18 11313 5 G 16 22,6 768,0 1270,0 6
11252 25 G 1 15,4 240,0 496,0 18 11314 7 G 16 24,8 1075,0 1794,0 6
11253 34 G 1 17,7 326,0 670,0 18 11315 3 G 25 22,3 720,0 1190,0 4
11254 37 G 1 17,9 355,0 713,0 18 11316 4 G 25 25,0 960,0 1594,0 4
11255 41 G 1 19,5 394,0 784,0 18 11317 5 G 25 27,7 1200,0 2014,0 4
11256 42 G 1 19,5 403,0 824,0 18 11318 3 G 35 25,9 1008,0 1590,0 2
11257 50 G 1 21,3 480,0 952,0 18 11319 4 G 35 28,7 1344,0 2200,0 2
11258 61 G 1 22,5 586,0 1140,0 18 11320 5 G 35 31,9 1680,0 2693,0 2
11259 65 G 1 23,6 628,0 1201,0 18 11321 3 G 50 30,8 1440,0 2571,0 1
11260 2 x 1,5 6,4 29,0 70,0 16 11322 4 G 50 34,1 1920,0 3087,0 1
11261 3 G 1,5 6,8 43,0 94,0 16 11323 5 G 50 38,1 2400,0 3980,0 1
11341 3 x 1,5 6,8 43,0 94,0 16 11324 3 G 70 36,4 2016,0 3207,0 2/0
11262 4 G 1,5 7,4 58,0 112,0 16 11325 4 G 70 40,2 2688,0 4077,0 2/0
11263 5 G 1,5 8,3 72,0 141,0 16 11326 5 G 70 44,7 3360,0 5501,0 2/0
11264 7 G 1,5 9,2 101,0 191,0 16 11327 3 G 95 41,3 2736,0 4708,0 3/0
11265 8 G 1,5 10,0 115,0 224,0 16 11328 4 G 95 46,0 3648,0 5590,0 3/0
11266 10 G 1,5 10,9 144,0 282,0 16 11329 5 G 95 50,7 4560,0 6972,0 3/0
11267 12 G 1,5 11,8 173,0 311,0 16 11330 3 G 120 47,0 3456,0 5515,0 4/0
11268 16 G 1,5 13,9 230,0 392,0 16 11331 4 G 120 51,0 4608,0 7100,0 4/0
11269 18 G 1,5 14,6 259,0 450,0 16
11270 20 G 1,5 15,6 288,0 497,0 16
11271 25 G 1,5 17,4 360,0 630,0 16
11272 34 G 1,5 20,2 490,0 842,0 16
11273 37 G 1,5 20,2 533,0 897,0 16
11274 50 G 1,5 24,2 720,0 1277,0 16
11275 61 G 1,5 25,8 878,0 1460,0 16
11276 65 G 1,5 26,8 936,0 1612,0 16

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

87
Flexible Control Cables / Halogen-free Control Cables UL/CSA

MEGAFLEX 500 halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, meter marking

Technical data Cable structure Properties


Halogen-free flexible control cable Bare copper-conductor, to Highly flame-retardant
adapted to DIN VDE 0295 cl.5, fine-wire, Resistant to oils and greases
DIN VDE 0285-525-3-11/ BS 6360 cl.5, IEC 60228 cl.5 Resistant to UV and weathering
DIN EN 50525-3-11, Core insulation of halogen-free Hydrolysis resistant
to UL-Style 20939, UL-Std.758 special polymer Flexible, abrasion- and wear-resistant
Temperature range Core identification to DIN VDE 0293 Ozone-resistant, recycleable
flexing -30C to +80C black cores with continuous white The materials used in manufacture are
fixed installation -40C to +80C numbering cadmium-free and contain no silicone
Nominal voltage GN-YE conductor, 3 cores and above and free from substances harmful to
U0/U 300/500 V in the outer layer the wetting properties of lacquers
UL/CSA 600 V Cores stranded in layers with Tests
Test voltage 3000 V optimal lay-length Flame test acc. to DIN VDE 0482-332-3-24,
Minimum bending radius Outer sheath of halogen-free BS 4066 part 3, DIN EN 60332-3-24,
flexing 10x cable special polymer IEC 60332-3-24 (previously DIN VDE 0472
fixed installation 4x cable Sheath colour grey (RAL 7001) part 804 test method C)
Flexible with meter marking Self-extinguishing and flame retardant
Alternate bending test acc. to LS0H= Low Smoke Zero Halogen acc. to DIN VDE 0482-332-1-2,
DIN VDE 0473-396 / DIN EN 50396 DIN EN 60332-1-2 / IEC 60332-1 (previously
Note DIN VDE 0472 part 804 test method B),
G = with green-yellow conductor CSA FT1
x = without green-yellow conductor (OZ) Corrosiveness of combustion gases
Also available as a 0,6/1 kV cable acc. to NF X 10-702
MEGAFLEX 600 Halogen-free acc. to DIN VDE 0482
AWG sizes are approximate equivalent part 267 / DIN EN 50267-2-1 / IEC 60754-1
values. The actual cross-section is in mm. (equivalent DIN VDE 0472 part 815)
screened analogue type: Smoke density acc. to DIN VDE 0482
MEGAFLEX 500-C, confer page 98 part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)
Approved to UL/CSA Oil-resistant to DIN VDE 0473-811-404/
see section N, page 394 DIN EN 60811-404
Hydrolysis-resistant to DIN EN 61234-1
Ozone-resistant to
DIN VDE 0473-811-403/DIN EN 60811-403

Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress, for high
mechanical strain. As a measuring and control cable primarily in machinery and plant construction, in air-conditoning systems, at the warehouse and
conveyor systems, in ship-building and in the renewable energies such as in the construction of wind power stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13344 2 x 0,5 20 5,0 9,6 43,0 13353 10 G 0,5 20 8,8 48,0 121,0
13345 3 G 0,5 20 5,3 14,4 50,0 13354 12 G 0,5 20 9,1 58,0 142,0
13346 3 x 0,5 20 5,3 14,4 50,0 13355 16 G 0,5 20 10,0 76,0 183,0
13347 4 G 0,5 20 5,7 19,0 60,0 13356 18 G 0,5 20 10,7 86,0 204,0
13348 4 x 0,5 20 5,7 19,0 60,0 13357 20 G 0,5 20 11,2 96,0 227,0
13349 5 G 0,5 20 6,2 24,0 71,0 13359 25 G 0,5 20 12,7 120,0 283,0
13350 5 x 0,5 20 6,2 24,0 71,0 13360 30 G 0,5 20 13,5 144,0 324,0
13351 7 G 0,5 20 7,4 33,6 84,0 13361 34 G 0,5 20 14,5 163,0 367,0
13352 8 G 0,5 20 8,0 38,0 101,0 13362 37 G 0,5 20 14,5 178,0 381,0

Continuation

88
Flexible Control Cables / Halogen-free Control Cables UL/CSA

MEGAFLEX 500 halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
A
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13363 41 G 0,5 20 15,8 197,0 417,0 13425 18 G 1,5 16 14,0 259,0 450,0
13364 42 G 0,5 20 15,8 202,0 454,0 13426 20 G 1,5 16 14,9 288,0 497,0
13365 50 G 0,5 20 17,3 240,0 519,0 13427 25 G 1,5 16 16,8 360,0 630,0
13366 61 G 0,5 20 18,5 293,0 635,0 13428 34 G 1,5 16 19,4 490,0 842,0
13367 65 G 0,5 20 19,4 312,0 694,0 13429 37 G 1,5 16 19,4 533,0 897,0
13368 2 x 0,75 19 5,4 14,4 47,0 13430 50 G 1,5 16 23,4 720,0 1277,0
13369 3 G 0,75 19 5,7 21,6 56,0 13431 61 G 1,5 16 24,8 878,0 1460,0
13370 3 x 0,75 19 5,7 21,6 56,0 13432 65 G 1,5 16 25,8 936,0 1612,0
13371 4 G 0,75 19 6,2 29,0 69,0 13433 2 x 2,5 14 7,6 48,0 118,0
13372 4 x 0,75 19 6,2 29,0 69,0 13434 3 G 2,5 14 8,3 72,0 151,0
13373 5 G 0,75 19 6,8 36,0 83,0 13435 4 G 2,5 14 9,1 96,0 181,0
13374 5 x 0,75 19 6,8 36,0 83,0 13436 5 G 2,5 14 10,2 120,0 224,0
13375 7 G 0,75 19 8,1 50,0 114,0 13437 7 G 2,5 14 12,1 168,0 316,0
13376 7 x 0,75 19 8,1 50,0 114,0 13438 8 G 2,5 14 13,2 192,0 370,0
13377 8 G 0,75 19 8,9 58,0 136,0 13439 10 G 2,5 14 14,6 240,0 451,0
13378 10 G 0,75 19 9,6 72,0 172,0 13440 12 G 2,5 14 15,2 288,0 499,0
13379 12 G 0,75 19 9,9 86,0 183,0 13441 16 G 2,5 14 16,8 384,0 720,0
13380 16 G 0,75 19 11,2 115,0 241,0 13442 18 G 2,5 14 18,1 432,0 769,0
13381 18 G 0,75 19 11,9 130,0 266,0 13443 20 G 2,5 14 19,0 480,0 911,0
13382 20 G 0,75 19 12,6 144,0 291,0 13444 25 G 2,5 14 22,2 600,0 1047,0
13383 25 G 0,75 19 14,1 180,0 374,0 13445 30 G 2,5 14 22,9 720,0 1280,0
13384 30 G 0,75 19 15,4 216,0 450,0 13446 2x4 12 9,2 77,0 199,0
13385 34 G 0,75 19 16,4 245,0 517,0 13447 3G4 12 9,9 115,0 247,0
13386 37 G 0,75 19 16,4 260,0 541,0 13448 4G4 12 11,0 154,0 299,0
13387 41 G 0,75 19 17,6 296,0 611,0 13449 5G4 12 12,1 192,0 369,0
13388 42 G 0,75 19 17,6 302,0 621,0 13450 7G4 12 13,3 269,0 463,0
13389 50 G 0,75 19 19,8 360,0 742,0 13451 8G4 12 15,9 307,0 601,0
13390 61 G 0,75 19 20,9 439,0 853,0 13452 10 G 4 12 17,3 384,0 698,0
13392 65 G 0,75 19 21,8 468,0 909,0 13453 12 G 4 12 18,3 461,0 790,0
13393 2x1 18 5,7 19,2 63,0 13454 16 G 4 12 20,2 614,0 1130,0
13394 3G1 18 6,0 29,0 74,0 13455 18 G 4 12 21,8 691,0 1280,0
13395 3x1 18 6,0 29,0 74,0 13456 2x6 10 10,8 115,0 266,0
13396 4G1 18 6,6 38,4 90,0 13457 3G6 10 11,7 173,0 360,0
13397 4x1 18 6,6 38,4 90,0 13458 4G6 10 13,0 230,0 429,0
13398 5G1 18 7,2 48,0 109,0 13459 5G6 10 14,5 288,0 529,0
13399 7G1 18 8,6 67,0 151,0 13460 7G6 10 16,0 403,0 631,0
13400 8G1 18 9,4 77,0 184,0 13461 2 x 10 8 14,0 192,0 440,0
13401 10 G 1 18 10,4 96,0 224,0 13462 3 G 10 8 15,0 288,0 550,0
13402 12 G 1 18 10,7 115,0 243,0 13463 4 G 10 8 16,8 384,0 708,0
13403 16 G 1 18 12,0 154,0 314,0 13464 5 G 10 8 18,7 480,0 862,0
13404 18 G 1 18 12,7 173,0 361,0 13465 7 G 10 8 20,6 672,0 1124,0
13405 20 G 1 18 13,5 192,0 387,0 13466 2 x 16 6 16,5 307,0 642,0
13406 25 G 1 18 15,2 240,0 496,0 13467 3 G 16 6 17,6 461,0 830,0
13407 34 G 1 18 17,4 326,0 670,0 13468 4 G 16 6 19,7 641,0 1060,0
13408 37 G 1 18 17,4 355,0 713,0 13469 5 G 16 6 21,9 768,0 1270,0
13409 41 G 1 18 18,9 394,0 784,0 13470 7 G 16 6 24,4 1075,0 1794,0
13410 42 G 1 18 18,9 403,0 824,0 13471 3 G 25 4 22,5 720,0 1190,0
13411 50 G 1 18 21,0 480,0 952,0 13472 4 G 25 4 25,2 960,0 1594,0
13412 61 G 1 18 22,2 586,0 1140,0 13473 5 G 25 4 27,9 1200,0 2014,0
13413 65 G 1 18 23,2 628,0 1201,0 13474 3 G 35 2 26,3 1008,0 1590,0
13414 2 x 1,5 16 6,3 29,0 70,0 13475 4 G 35 2 28,5 1344,0 2200,0
13415 3 G 1,5 16 6,6 43,0 94,0 13476 5 G 35 2 31,2 1680,0 2693,0
13416 3 x 1,5 16 6,6 43,0 94,0 13477 3 G 50 1 30,2 1440,0 2571,0
13417 4 G 1,5 16 7,2 58,0 112,0 13478 4 G 50 1 34,0 1920,0 3087,0
13418 5 G 1,5 16 7,9 72,0 141,0 13479 5 G 50 1 37,8 2400,0 3980,0
13419 7 G 1,5 16 9,5 101,0 191,0 13480 3 G 70 2/0 37,0 2016,0 3207,0
13420 8 G 1,5 16 10,4 115,0 224,0 13481 4 G 70 2/0 41,5 2688,0 4077,0
13421 10 G 1,5 16 11,3 144,0 282,0 13482 5 G 70 2/0 46,2 3360,0 5501,0
13422 12 G 1,5 16 11,7 173,0 311,0 13483 3 G 95 3/0 41,4 2736,0 4708,0
13423 16 G 1,5 16 13,3 230,0 392,0 13484 4 G 95 3/0 46,2 3648,0 5590,0
13485 5 G 95 3/0 51,5 4560,0 6972,0
13486 3 G 120 4/0 45,7 3456,0 5515,0
13487 4 G 120 4/0 51,2 4608,0 7100,0
13488 3 G 150 300 kcmil 52,8 4320,0 6279,0
13489 4 G 150 300 kcmil 58,3 5760,0 7781,0

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

89
Halogen-free hose cable

H07ZZ-F control cable, cross linked, halogen-free

Technical data Cable structure Properties


halogen-free cross-linked control cable Bare copper-conductor, to Test
to DIN VDE 0285-525-3-21 / DIN VDE 0295 cl.5, fine-wire, Behaviour in fire
DIN EN 50525-3-21 BS 6360 cl.5, IEC 60228 cl.5, HD 383 to DIN VDE 0482-332-1-2,
Temperature range Core insulation of halogen-free, DIN EN 60332-1-2, IEC 60332-1
flexing -5C to +70C cross-linked EI8 to and IEC 60332-3-24
fixed installation -20C to +70C DIN VDE 0207-363-5/DIN EN 50363-5 Corrosiveness of combustion gases
Permissible operating temperature Core identification to DIN VDE 0293-308 acc. to EN 50267-2-2
at conductor +90C Cores stranded in layers with Smoke density to DIN VDE 0482
Nominal voltage optimal lay-length part 1034-1+2, DIN EN 61034-1+2,
flexing U0/U 450/750 V Outer sheath of halogen-free, IEC 61034-1+2
fixed installation U0/U 0,6/1 kV cross-linked EM8 to Ozone resistant of single core the
Test voltage 2500 V DIN VDE 0207-363-6/DIN EN 50363-6 insulation to DIN VDE 0473-811-403 /
Permanent tensile load Sheath colour black DIN EN 60811-403
max. 15 N/mm
under consideration of Note
total copper cross-sections G = with green-yellow conductor
Minimum bending radius x = without green-yellow conductor
flexing 10x cable AWG sizes are approximate equivalent
for fixed installation 4x cable values. The actual cross-section is in mm.

Application
Single and multicore sheathed cable, with low smoke and corrosive gas production in case of fire for interior use. Not suitable for continuous outside
use. In this case, cable with a special tested covering should be used. Skin contact should be avoided when the cable is used in high temperatures.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm approx. mm kg / km kg / km mm approx. mm kg / km kg / km
37176 1 x 1,5 5,7 - 7,1 14,4 58,0 16 37218 3 G 300 72,0 - 90,0 8640,0 12620,0 600 kcmil
37177 1 x 2,5 6,3 - 7,9 24,0 71,0 14 37219 4G1 9,2 - 11,9 38,0 141,0 18
37178 1x4 7,2 - 9,0 38,0 100,0 12 37220 4 G 1,5 10,2 - 13,1 58,0 176,0 16
37179 1x6 7,9 - 9,8 58,0 130,0 10 37221 4 G 2,5 12,1 - 15,5 96,0 235,0 14
37180 1 x 10 9,5 - 11,9 96,0 230,0 8 37222 4G4 14,0 - 17,9 154,0 365,0 12
37181 1 x 16 10,8 - 13,4 154,0 290,0 6 37223 4G6 15,7 - 20,0 230,0 501,0 10
37182 1 x 25 12,7 - 15,8 240,0 420,0 4 37224 4 G 10 20,9 - 26,5 384,0 872,0 8
37183 1 x 35 14,3 - 17,9 336,0 530,0 2 37225 4 G 16 23,8 - 30,1 614,0 1194,0 6
37184 1 x 50 16,5 - 20,6 480,0 750,0 1 37226 4 G 25 28,9 - 36,6 960,0 1822,0 4
37185 1 x 70 18,6 - 23,3 672,0 960,0 2/0 37227 4 G 35 32,5 - 41,1 1344,0 2307,0 2
37186 1 x 95 20,8 - 26,0 912,0 1250,0 3/0 37228 4 G 50 37,7 - 47,5 1920,0 3253,0 1
37187 1 x 120 22,8 - 28,6 1152,0 1560,0 4/0 37229 4 G 70 42,7 - 54,0 2688,0 4130,0 2/0
37188 1 x 150 25,2 - 31,4 1440,0 1900,0 300 kcmil 37230 4 G 95 48,4 - 61,0 3648,0 5720,0 3/0
37189 1 x 185 27,6 - 34,4 1776,0 2300,0 350 kcmil 37231 4 G 120 53,0 - 66,0 4608,0 6965,0 4/0
37190 1 x 240 30,6 - 38,3 2304,0 2950,0 500 kcmil 37232 4 G 150 58,0 - 73,0 5760,0 8644,0 300 kcmil
37191 1 x 300 33,5 - 41,9 2880,0 3600,0 600 kcmil 37233 4 G 185 64,0 - 80,0 7104,0 10598,0 350 kcmil
37192 1 x 400 37,4 - 46,8 3840,0 4600,0 750 kcmil 37234 4 G 240 72,0 - 91,0 9216,0 12100,0 500 kcmil
37193 1 x 500 41,3 - 52,0 4800,0 6000,0 1000 kcmil 37235 4 G 300 80,0 - 101,0 11520,0 15200,0 600 kcmil
37194 2x1 7,7 - 10,0 19,0 95,0 18 37236 5G1 10,2 - 13,1 48,0 170,0 18
37195 2 x 1,5 8,5 - 11,0 29,0 119,0 16 37237 5 G 1,5 11,2 - 14,4 72,0 214,0 16
37196 2 x 2,5 10,2 - 13,1 48,0 172,0 14 37238 5 G 2,5 13,3 - 17,0 120,0 316,0 14
37197 2x4 11,8 - 15,1 77,0 239,0 12 37239 5G4 15,6 - 19,9 192,0 448,0 12
37198 2x6 13,1 - 16,8 115,0 319,0 10 37240 5G6 17,5 - 22,2 288,0 607,0 10
37199 2 x 10 17,7 - 22,6 192,0 572,0 8 37241 5 G 10 22,9 - 29,1 480,0 1075,0 8
37200 2 x 16 20,2 - 25,7 307,0 767,0 6 37242 5 G 16 26,4 - 33,3 768,0 1480,0 6
37201 2 x 25 24,3 - 30,7 480,0 1154,0 4 37243 5 G 25 32,0 - 40,4 1200,0 2255,0 4
37202 3G1 8,3 - 10,7 29,0 115,0 18 37244 6 G 1,5 13,4 - 17,2 84,0 287,0 16
37203 3 G 1,5 9,2 - 11,9 43,0 144,0 16 37245 6 G 2,5 15,7 - 20,0 144,0 420,0 14
37204 3 G 2,5 10,9 - 14,0 72,0 211,0 14 37246 6G4 18,2 - 23,2 230,0 583,0 12
37205 3G4 12,7 - 16,2 115,0 290,0 12 37247 7 G 1,5 11,4 - 14,4 101,0 303,0 16
37206 3G6 14,1 - 18,0 173,0 391,0 10 37248 7 G 2,5 13,4 - 17,0 168,0 448,0 14
37207 3 G 10 19,1 - 24,2 288,0 706,0 8 37249 12 G 1,5 17,6 - 22,4 173,0 496,0 16
37208 3 G 16 21,8 - 27,6 461,0 961,0 6 37250 12 G 2,5 20,6 - 26,2 288,0 724,0 14
37209 3 G 25 26,1 - 33,0 720,0 1438,0 4 37251 12 G 4 24,4 - 30,9 461,0 1042,0 12
37210 3 G 35 29,3 - 37,1 1008,0 1814,0 2 37252 18 G 1,5 20,7 - 26,3 259,0 702,0 16
37211 3 G 50 34,1 - 42,9 1440,0 2550,0 1 37253 18 G 2,5 24,4 - 30,9 432,0 1045,0 14
37212 3 G 70 38,4 - 48,3 2016,0 3210,0 2/0 37254 18 G 4 28,8 - 36,4 691,0 1430,0 12
37213 3 G 95 43,3 - 54,0 2736,0 4423,0 3/0 37255 24 G 1,5 24,3 - 30,7 346,0 935,0 16
37214 3 G 120 47,4 - 60,0 3456,0 5405,0 4/0 37256 24 G 2,5 28,8 - 36,4 576,0 1325,0 14
37215 3 G 150 52,0 - 66,0 4320,0 6725,0 300 kcmil 37257 36 G 1,5 27,8 - 35,2 518,0 1297,0 16
37216 3 G 185 57,0 - 72,0 5328,0 8222,0 350 kcmil 37258 36 G 2,5 33,2 - 41,8 864,0 1949,0 14
37217 3 G 240 65,0 - 82,0 6192,0 10224,0 500 kcmil

Dimensions and specifications may be changed without prior notice. (RF01)

90
Flexible Control Cables / Halogen-free Control Cables

JZ-600 HMH flexible control cable, halogen-free, extremely fire resistant, oil
resistant , 0,6/1kV, meter marking
1)

Technical data Cable structure Properties


Halogen-free, flexible control cable, Bare copper-conductor, to For critical applications, we recommend
1)

adapted to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, that you consult
DIN EN 50525-2-51 and BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
DIN VDE 0285-525-3-11/ Core insulation of halogen-free polymer cadmium-free and contain no silicone
DIN EN 50525-3-11 compound type TI6 to and free from substances harmful to
Temperature range DIN VDE 0207-363-7 / DIN EN 50363-7 the wetting properties of lacquers
flexing -15C to +70C Core identification to DIN VDE 0293 Tests
fixed -40C to +70C black cores with continuous white Flame test acc. to
Nominal voltage U0/U 0,6/1 kV numbering DIN VDE 0482-332-3, BS 4066 part 3,
Test voltage 4000 V GN-YE conductor, 3 cores and above DIN EN 60332-3, IEC 60332-3 (previously
Minimum bending radius in the outer layer DIN VDE 0472 part 804 test method C)
flexing 15x cable Cores stranded in layers with self-extinguishing and flame retardant
fixed installation 7,5x cable optimal lay-length acc. to DIN VDE 0482-332-1-2,
Radiation resistance Outer sheath of halogen-free polymer DIN EN 60332-1-2/IEC 60332-1 (equivalent
up to 100x106 cJ/kg (up to 100 Mrad) compound type TM7 to DIN VDE 0472 part 804 test method B)
DIN VDE 0207-363-8 / DIN EN 50363-8 Corrosiveness of combustion gases
Sheath colour black (RAL 9005) acc. to DIN VDE 0482 part 267,
with meter marking DIN EN 50267-2-2, IEC 60754-2
LS0H= Low Smoke Zero Halogen (equivalent DIN VDE 0472 part 813)
Halogen-free acc. to DIN VDE 0482 Part 267/
DIN EN 50267-2-1 / IEC 60754-1 (as per
DIN VDE 0472, Part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-600 HMH-C, confer page 100

Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as in plant
installations, in heating and air-conditioning systems and steel production works. For fixed installation or flexible application, directed without forcing
by casual, constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the application in
dry, damp and wet environments, outdoors (fixed installation) and for laying on plaster.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12723 2 x 0,5 6,3 9,6 57,0 20 12735 2 x 0,75 6,6 14,4 68,0 19
12724 3 G 0,5 6,6 14,4 69,0 20 12736 3 G 0,75 6,9 21,6 77,0 19
12725 3 x 0,5 6,6 14,4 69,0 20 12737 3 x 0,75 6,9 21,6 77,0 19
12726 4 G 0,5 7,2 19,0 104,0 20 12738 4 G 0,75 7,5 29,0 136,0 19
12727 4 x 0,5 7,2 19,0 104,0 20 12739 4 x 0,75 7,5 29,0 136,0 19
12728 5 G 0,5 8,0 24,0 121,0 20 12740 5 G 0,75 8,4 36,0 152,0 19
12729 5 x 0,5 8,0 24,0 121,0 20 12741 5 x 0,75 8,4 36,0 152,0 19
12730 7 G 0,5 8,7 33,6 145,0 20 12742 7 G 0,75 9,3 50,0 208,0 19
12731 10 G 0,5 10,3 48,0 186,0 20 12743 10 G 0,75 11,4 72,0 250,0 19
12732 12 G 0,5 11,2 58,0 224,0 20 12744 12 G 0,75 12,2 86,0 271,0 19
12733 18 G 0,5 13,8 86,0 292,0 20 12745 18 G 0,75 14,5 130,0 387,0 19
12734 25 G 0,5 16,1 120,0 357,0 20 12746 25 G 0,75 17,2 180,0 498,0 19

Continuation

91
Flexible Control Cables / Halogen-free Control Cables

JZ-600 HMH flexible control cable, halogen-free, extremely fire resistant, oil
resistant , 0,6/1kV, meter marking
1)

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12747 2x1 7,0 19,2 82,0 18 12783 3G4 11,7 115,0 255,0 12
12748 3G1 7,4 29,0 99,0 18 12784 4G4 12,9 154,0 319,0 12
12749 3x1 7,4 29,0 99,0 18 12785 5G4 14,4 192,0 423,0 12
12750 4G1 8,2 38,4 140,0 18 12786 3G6 13,1 173,0 380,0 10
12751 4x1 8,2 38,4 140,0 18 12787 4G6 14,5 230,0 441,0 10
12752 5G1 9,2 48,0 160,0 18 12788 5G6 16,2 288,0 657,0 10
12753 5x1 9,2 48,0 160,0 18 12789 3 G 10 16,8 288,0 668,0 8
12754 7G1 9,9 67,0 217,0 18 12790 4 G 10 18,5 384,0 796,0 8
12755 10 G 1 11,9 96,0 271,0 18 12791 5 G 10 20,5 480,0 972,0 8
12756 12 G 1 12,8 115,0 301,0 18 12792 3 G 16 20,2 461,0 832,0 6
12757 18 G 1 15,7 173,0 417,0 18 12793 4 G 16 22,4 614,0 1122,0 6
12758 25 G 1 18,6 240,0 576,0 18 12794 5 G 16 25,0 768,0 1604,0 6
12759 2 x 1,5 8,2 29,0 97,0 16 12795 3 G 25 24,8 720,0 1457,0 4
12760 3 G 1,5 8,6 43,0 119,0 16 12796 4 G 25 27,4 960,0 1611,0 4
12761 3 x 1,5 8,6 43,0 119,0 16 12797 5 G 25 30,5 1200,0 2070,0 4
12762 4 G 1,5 9,6 58,0 148,0 16 12798 3 G 35 27,4 1008,0 1914,0 2
12763 4 x 1,5 9,6 58,0 148,0 16 12799 4 G 35 30,3 1344,0 2424,0 2
12764 5 G 1,5 10,7 72,0 172,0 16 12800 5 G 35 33,6 1680,0 2970,0 2
12765 5 x 1,5 10,7 72,0 172,0 16 12801 4 G 50 35,8 1920,0 3467,0 1
12766 7 G 1,5 11,6 101,0 243,0 16 12802 4 G 70 40,8 2688,0 4491,0 2/0
12767 10 G 1,5 15,2 144,0 311,0 16 12803 4 G 95 46,2 3648,0 6170,0 3/0
12768 12 G 1,5 15,5 173,0 392,0 16 12804 4 G 120 51,6 4608,0 7618,0 4/0
12769 18 G 1,5 18,6 259,0 529,0 16
12770 25 G 1,5 22,5 360,0 741,0 16
12771 2 x 2,5 9,6 48,0 160,0 14
12772 3 G 2,5 10,1 72,0 177,0 14
12773 3 x 2,5 10,1 72,0 177,0 14
12774 4 G 2,5 11,2 96,0 209,0 14
12775 4 x 2,5 11,2 96,0 209,0 14
12776 5 G 2,5 12,5 120,0 272,0 14
12777 5 x 2,5 12,5 120,0 272,0 14
12778 7 G 2,5 13,8 168,0 340,0 14
12779 10 G 2,5 16,6 288,0 561,0 14
12780 12 G 2,5 18,3 432,0 799,0 14
12781 18 G 2,5 22,0 480,0 940,0 14
12782 25 G 2,5 26,2 600,0 1121,0 14

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

92
Flexible Control Cables / Halogen-free Control Cables

JB-750 HMH flexible control cable, coloured core, halogen-free, extremely fire
resistant, oil resistant , meter marking
1)

Technical data Cable structure Properties


Halogen-free flexible control cable, Bare copper-conductor, to ) We recommend you for critcal
adapted to DIN VDE 0295 cl.5, fine-wire, applications a consultation
DIN VDE 0285-525-2-51 / BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
DIN EN 50525-2-51 and Core insulation of halogen-free polymer cadmium-free and contain no silicone
DIN VDE 0285-525-3-11/ compound type TI6 to and free from substances harmful to
DIN EN 50525-3-11 DIN VDE 0207-363-7 / DIN EN 50363-7 the wetting properties of lacquers
Temperature range Core identification to DIN VDE 0293-308 Tests
flexing -15C to +70C GN-YE conductor Flame test acc. to
fixed installation -40C to +70C Cores stranded in layers with DIN VDE 0482-332-3, BS 4066 part 3,
Nominal voltage U0/U 450/750 V optimal lay-length DIN EN 60332-3, IEC 60332-3 (previously
Test voltage 3000 V Outer sheath of halogen-free polymer DIN VDE 0472 part 804 test method C)
Minimum bending radius compound type TM7 to self-extinguishing and flame retardant
flexing 12,5x cable DIN VDE 0207-363-8 / DIN EN 50363-8 acc. to DIN VDE 0482-332-1-2,
fixed installation 4x cable Sheath colour grey (RAL 7001) DIN EN 60332-1-2, IEC 60332-1 (equivalent
Radiation resistance with meter marking DIN VDE 0472 part 804 test method B)
up to 100x106 cJ/kg (up to 100 Mrad) LS0H= Low Smoke Zero Halogen Corrosiveness of combustion gases
acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-2, IEC 60754-2
(equivalent DIN VDE 0472 part 813)
Halogen-free acc. to DIN VDE 0482
part 267 / DIN EN 50267-2-1 / IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
Please note the cleanroom qualification
when ordering.
AWG sizes are approximate equivalent
values.
The actual cross-section is in mm.
screened analogue type:
JB-750 HMH-C, confer page 102

Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as in plant
installations, in air-conditioning and steel production works. For fixed installation or flexible application, directed without forcing by casual, not
constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the application in dry, damp
and wet environments and also for laying on plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11965 3 G 1,5 7,8 43,0 110,0 16 11976 4 G 10 18,1 384,0 750,0 8
11966 4 G 1,5 8,5 58,0 140,0 16 11977 5 G 10 20,1 480,0 916,0 8
11967 5 G 1,5 9,6 72,0 181,0 16 11978 4 G 16 22,0 614,0 1037,0 6
11968 3 G 2,5 9,3 72,0 181,0 14 11979 5 G 16 24,4 768,0 1280,0 6
11969 4 G 2,5 10,2 96,0 223,0 14 11980 4 G 25 27,1 960,0 1504,0 4
11970 5 G 2,5 11,4 120,0 269,0 14 11981 5 G 25 30,1 1200,0 1883,0 4
11971 3G4 11,3 115,0 238,0 12 11982 4 G 35 29,9 1344,0 2057,0 2
11972 4G4 12,5 154,0 292,0 12 11983 5 G 35 33,4 1680,0 2575,0 2
11973 5G4 13,9 192,0 357,0 12 11984 4 G 50 35,5 1920,0 2808,0 1
11974 4G6 14,2 230,0 392,0 10 11985 4 G 70 40,2 2688,0 3964,0 2/0
11975 5G6 15,8 288,0 501,0 10 11986 4 G 95 46,0 3648,0 4951,0 3/0
11987 4 G 120 51,3 4608,0 6387,0 4/0

Dimensions and specifications may be changed without prior notice. (RA03)

93
Flexible Control Cables / Halogen-free Control Cables

(H)03Z1Z1-F halogen-free, meter marking

Technical data Cable structure Properties


flexible halogen-free control cable Bare copper-conductor, to The materials used in manufacture are
adapted to DIN VDE 0285-525-3-11 / DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN EN 50525-3-11 BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
Temperature range Core insulation of thermoplastic the wetting properties of lacquers
flexing -5C to +70C compound Tests
fixed installation -40C to +70C Core identification to DIN VDE 0293-308 Tested for flame retardation
Nominal voltage U0/U 300/300 V GN-YE conductor, 3 cores and above acc. to DIN VDE 0482-332-1-2,
Test voltage 2000 V Outer sheath of thermoplastic DIN EN 60332-1-2, IEC 60332-1 (equivalent
Breakdown voltage min. 4000 V compound DIN VDE 0472 part 804 test method B)
Minimum bending radius Sheath colour by request Smoke density acc. to DIN VDE
7,5x cable with meter marking 0482-1034-1+2,
Radiation resistance DIN EN 61034-1+2, IEC 61034-1+2
up to 20x106 cJ/kg (up to 20 Mrad) Halogen-free acc. to
DIN VDE 0285-525-1, DIN EN 50525-1

Note
G = with green-yellow conductor
x = without green-yellow conductor
Please complete the part number for
these cables by adding the suffix for
the colour required as per the list:
0 = ca.RAL 9005 black
1 = ca.RAL 9003 withe
2 = ca.RAL 5015 blue
3 = ca.RAL 6018 green
4 = ca.RAL 8003 brown
5 = ca.RAL 1021 yellow
6 = ca.RAL 3000 red
7 = ca.RAL 2003 orange
8 = ca.RAL 4005 violet
9 = ca.RAL 7001/7032 grey
Further colours on request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables may be used when halogen-free, low smoke and corrosive gas properties are required in case of fire. For low mechanical demands in
the house, kitchen and office, for small equipment such as, for example, office machines, radios, table and stranded lamps.
Not suitable for:
Cooking and heating equipment, use in high temperature areas (for example, in lighting equipment), outside use, industrial use or idustrial electrical
tools, cables with a nominal cross-section of 0,75 mm comply with the same recommendations as for cable (H)05Z1Z1-F.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
3233x 2 x 0,5 5,1 9,6 39,0 20 3236x 2 x 0,75 5,4 14,4 47,0 19
3234x 3 G 0,5 5,4 14,4 46,0 20 3237x 3 G 0,75 5,7 21,6 55,0 19
3235x 4 G 0,5 5,9 19,2 56,0 20 3238x 4 G 0,75 6,3 29,0 69,0 19

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

94
Flexible Control Cables / Halogen-free Control Cables

(H)05Z1Z1-F halogen-free, meter marking

Technical data Cable structure Properties


flexible halogen-free control cable Bare copper-conductor, to The materials used in manufacture are
adapted to DIN VDE 0285-525-3-11/ DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN EN 50525-3-11 BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
Temperature range Core insulaion thermoplastic the wetting properties of lacquers
flexing -5C to +70C compound Tests
fixed installation -40C to +70C Core identification to DIN VDE 0293-308 Tested for flame retardation
Nominal voltage U0/U 300/500 V GN-YE conductor, 3 cores and above acc. to DIN VDE 0482-332-1-2,
Test voltage 2000 V Cores stranded with optimal lay-length DIN EN 60332-1-2, IEC 60332-1 (equivalent
Breakdown voltage min. 4000 V Outer sheath of thermoplastic DIN VDE 0472 part 804 test method B)
Minimum bending radius compound Smoke density acc. to
7,5x cable Sheath colour by request DIN VDE 0482-1034-1+2,
Radiation resistance with meter marking DIN EN 61034-1+2, IEC 61034-1+2
up to 20x106 cJ/kg (up to 20 Mrad) Halogen-free acc. to
DIN VDE 0285-525-1, DIN EN 50525-1

Note
G = with green-yellow conductor
x = without green-yellow conductor
Please complete the part number for
these cables by adding the suffix for
the colour required as per the list:
0 = ca.RAL 9005 black
1 = ca.RAL 9003 withe
2 = ca.RAL 5015 blue
3 = ca.RAL 6018 green
4 = ca.RAL 8003 brown
5 = ca.RAL 1021 yellow
6 = ca.RAL 3000 red
7 = ca.RAL 2003 orange
8 = ca.RAL 4005 violet
9 = ca.RAL 7001/7032 grey
Further colours on request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables may be used when halogen-free, low smoke and corrosive gas properties are required in case of fire. For moderate mechanical demands
in the house, kitchen and office, for house equipment in damp rooms (for example: washing machines, spin-dryers and refrigerators).
Suitable for cooking and heating equipment, providing the cable is not in contact with hot components or heat radiation.
Not suitable for:
in high temperature areas (for example, in lighting equipment), outside buildings, in industrial or agricultural buildings, connection of electrical power
tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
3027x 2 x 0,75 6,3 14,4 58,0 19 3043x 5 G 2,5 12,0 120,0 260,0 14
3028x 3 G 0,75 6,6 21,6 68,0 19 3044x 2x4 10,4 76,8 190,0 12
3029x 4 G 0,75 7,2 29,0 81,0 19 3045x 3G4 11,3 115,2 242,0 12
3030x 5 G 0,75 8,0 36,0 102,0 19 3046x 4G4 12,3 153,6 298,0 12
3031x 2x1 6,5 19,0 67,0 18 3047x 5G4 13,9 192,0 371,0 12
3032x 3G1 6,9 29,0 81,0 18
3034x 4G1 7,7 38,0 101,0 18
3035x 5G1 8,4 48,0 107,0 18
3036x 2 x 1,5 7,4 29,0 87,0 16
3037x 3 G 1,5 8,0 43,0 109,0 16
3038x 4 G 1,5 9,1 58,0 117,0 16
3039x 5 G 1,5 10,0 72,0 169,0 16
3040x 2 x 2,5 9,1 48,0 138,0 14
3041x 3 G 2,5 9,9 72,0 172,0 14
3042x 4 G 2,5 10,8 96,0 210,0 14

Dimensions and specifications may be changed without prior notice. (RA03)

95
Flexible Control Cables / Halogen-free Control Cables

JZ-500 HMH-C flexible control cable, halogen-free, extremely fire resistant,


oil resistant , Cu-screened, EMC-preferred type, meter marking
1)

Technical data Cable structure Properties


Halogen-free core flexible control cable Bare copper-conductor, to ) We recommend you for critical
adapted to DIN VDE 0285-525-2-51 / DIN VDE 0295 cl.5, fine-wire, applications a consultation
DIN EN 50525-2-51 and BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
DIN VDE 0285-525-3-11/ Core insulation of halogen-free polymer cadmium-free and contain no silicone
DIN EN 50525-3-11 compound type TI6 to and free from substances harmful to
Temperature range DIN VDE 0207-363-7 / DIN EN 50363-7 the wetting properties of lacquers
flexing -15C to +70C Core identification to DIN VDE 0293 Tests
fixed installation -40C to +70C black cores with continuous white Flame test acc. to
Nominal voltage U0/U 300/500 V numbering DIN VDE 0482-332-3, BS 4066 part 3,
Test voltage 2000 V GN-YE conductor, 3 cores and above DIN EN 60332-3, IEC 60332-3 (previously
Coupling resistance in the outer layer DIN VDE 0472 part 804 test method C)
max. 250 Ohm/km Cores stranded in layers with self-extinguishing and flame retardant
Minimum bending radius optimal lay-length acc. to DIN VDE 0482-332-1-2,
flexing 12,5x cable Separating foil DIN EN 60332-1-2/IEC 60332-1(equivalent
fixed installation 4x cable Tinned copper braided screen, DIN VDE 0472 part 804 test method B)
Radiation resistance approx. 85% coverage Corrosiveness of combustion gases
up to 100x106 cJ/kg (up to 100 Mrad) Outer sheath of halogen-free spolymer acc. to DIN VDE 0482 part 267,
compound type TM7 to DIN EN 50267-2-2, IEC 60754-2
DIN VDE 0207-363-8 / DIN EN 50363-8 (equivalent DIN VDE 0472 part 813)
Sheath colour grey (RAL 7001) Halogen-free acc. to DIN VDE 0482
with meter marking part 267, DIN EN 50267-2-1, IEC 60754-1
LS0H= Low Smoke Zero Halogen (equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified" when
ordering.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-500 HMH, confer page 86

Application
Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts,
production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for
casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable
for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of
screening.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11656 2 x 0,5 5,7 35,0 46,0 20 11678 2 x 0,75 6,1 40,0 60,0 19
11657 3 G 0,5 5,9 42,0 56,0 20 11679 3 G 0,75 6,3 52,0 68,0 19
11342 3 x 0,5 5,9 42,0 56,0 20 11344 3 x 0,75 6,3 52,0 68,0 19
11658 4 G 0,5 6,4 47,0 62,0 20 11680 4 G 0,75 6,8 60,0 78,0 19
11343 4 x 0,5 6,4 47,0 62,0 20 11345 4 x 0,75 6,8 60,0 78,0 19
11659 5 G 0,5 6,9 56,0 75,0 20 11681 5 G 0,75 7,4 71,0 95,0 19
11660 7 G 0,5 7,6 69,0 98,0 20 11346 5 x 0,75 7,4 71,0 95,0 19
11663 12 G 0,5 9,7 108,0 158,0 20 11682 7 G 0,75 8,2 91,0 130,0 19
11665 18 G 0,5 11,5 145,0 216,0 20 11347 7 x 0,75 8,2 91,0 130,0 19
11667 25 G 0,5 13,7 240,0 315,0 20 11685 12 G 0,75 10,5 142,0 203,0 19

Continuation

96
Flexible Control Cables / Halogen-free Control Cables

JZ-500 HMH-C flexible control cable, halogen-free, extremely fire resistant,


oil resistant , Cu-screened, EMC-preferred type, meter marking
1)

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11687 18 G 0,75 12,7 212,0 290,0 19 11781 2G6 11,7 173,0 270,0 10
11689 25 G 0,75 15,0 281,0 413,0 19 11782 3G6 12,5 240,0 328,0 10
11700 2x1 6,4 50,0 66,0 18 11783 4G6 13,8 305,0 416,0 10
11701 3G1 6,7 60,0 80,0 18 11784 5G6 15,4 439,0 510,0 10
11348 3x1 6,7 60,0 80,0 18 11785 7G6 17,0 505,0 670,0 10
11702 4G1 7,2 71,0 100,0 18 11786 2 x 10 14,5 255,0 420,0 8
11349 4x1 7,2 71,0 100,0 18 11787 3 G 10 15,6 350,0 495,0 8
11703 5G1 8,0 88,0 130,0 18 11788 4 G 10 17,2 535,0 785,0 8
11704 7G1 8,7 111,0 160,0 18 11789 5 G 10 19,1 592,0 855,0 8
11707 12 G 1 11,4 184,0 260,0 18 11790 7 G 10 21,2 810,0 1308,0 8
11709 18 G 1 13,6 260,0 382,0 18 11793 4 G 16 20,3 740,0 882,0 6
11711 25 G 1 16,2 349,0 540,0 18 11794 5 G 16 22,2 895,0 1293,0 6
11722 2 x 1,5 7,0 63,0 88,0 16 11812 7 G 16 24,8 1282,0 2149,0 6
11723 3 G 1,5 7,4 80,0 100,0 16 11795 3 G 25 22,5 1070,0 1432,0 4
11350 3 x 1,5 7,4 80,0 100,0 16 11796 4 G 25 25,0 1140,0 1911,0 4
11724 4 G 1,5 8,1 97,0 125,0 16 11797 5 G 25 27,5 1380,0 2414,0 4
11725 5 G 1,5 9,0 119,0 158,0 16 11798 3 G 35 25,7 1240,0 1914,0 2
11726 7 G 1,5 9,8 147,0 210,0 16 11799 4 G 35 28,5 1576,0 2542,0 2
11729 12 G 1,5 12,8 267,0 340,0 16 11800 5 G 35 31,7 1930,0 3180,0 2
11731 18 G 1,5 15,6 374,0 480,0 16 11801 3 G 50 30,8 1675,0 3080,0 1
11733 25 G 1,5 18,4 526,0 702,0 16 11802 4 G 50 34,1 2155,0 3550,0 1
11744 2 x 2,5 8,4 96,0 132,0 14 11803 5 G 50 38,1 2794,0 4753,0 1
11745 3 G 2,5 8,8 144,0 168,0 14 11804 3 G 70 36,0 2288,0 3840,0 2/0
11746 4 G 2,5 9,8 148,0 195,0 14 11805 4 G 70 40,0 3120,0 4939,0 2/0
11747 5 G 2,5 10,8 181,0 222,0 14 11806 5 G 70 44,5 3705,0 6572,0 2/0
11748 7 G 2,5 11,9 255,0 345,0 14 11807 3 G 95 41,1 3010,0 5651,0 3/0
11751 12 G 2,5 15,8 441,0 572,0 14 11808 4 G 95 45,6 4043,0 6690,0 3/0
11766 2x4 10,0 120,0 184,0 12 11809 5 G 95 50,7 5026,0 8370,0 3/0
11768 3G4 10,6 174,0 238,0 12 11810 3 G 120 45,2 3812,0 6342,0 4/0
11769 4G4 11,6 230,0 305,0 12 11811 4 G 120 50,1 5069,0 8453,0 4/0
11770 5G4 12,8 273,0 388,0 12 11813 4 G 185 63,0 8040,0 10800,0 350 kcmil
11771 7G4 14,2 316,0 504,0 12

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

97
Flexible Control Cables / Halogen-free Control Cables UL/CSA

MEGAFLEX 500-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, screened, EMC-preferred types, meter marking

Technical data Cable structure Properties


Halogen-free flexible control cable Bare copper, fine wire conductors, to Halogen-free
adapted to DIN VDE 0295 cl.5, BS 6360 cl.5 and Highly flame-retardant
DIN VDE 0285-525-3-11 / IEC 60228 cl.5 Resistant to oils and greases
DIN EN 50525-3-11, Core insulation of halogen-free Resistant to UV and weathering
to UL-Style 20939, UL-Std.758 special polymer Flexible, abrasion- and wear-resistant
Temperature range Core identification to DIN VDE 0293 Ozone-resistant
flexing -30C to +80C black cores with continuous white Recycleable
fixed installation -40C to +80C numbering The materials used in manufacture are
Nominal voltage GN-YE conductor, 3 cores and above cadmium-free and contain no silicone
U0/U 300/500 V in the outer layer and free from substances harmful to
UL/CSA 600 V Cores stranded in layers with the wetting properties of lacquers
Test voltage 3000 V optimal lay-length Tests
Coupling resistance Separating foil Flame test acc. to DIN VDE 0482-332-3-24,
max. 250 Ohm/km Tinned copper braided screen, BS 4066 part 3, DIN EN 60332-3-24,
Minimum bending radius approx. 85% coverage IEC 60332-3-24 (previously DIN VDE 0472
flexing 10x cable Outer sheath of halogen-free part 804 test method C)
fixed installation 4x cable special polymer Self-extinguishing and flame retardant
Flexible Sheath colour grey (RAL 7001) acc. to DIN VDE 0482-332-1-2,
Alternate bending test acc. to with meter marking DIN EN 60332-1-2, IEC 60332-1 (previously
DIN VDE 0473-396 / DIN EN 50396 LS0H= Low Smoke Zero Halogen DIN VDE 0472 part 804 test method B)
CSA FT1
Note Corrosiveness of combustion gases acc. to
G = with green-yellow conductor NF X 10-702
x = without green-yellow conductor (OZ) Halogen-free acc. to DIN VDE 0482
AWG sizes are approximate equivalent part 267, DIN EN 50267-2-1, IEC 60754-1
values. The actual cross-section is in mm. (equivalent DIN VDE 0472 part 815)
unscreened analogue type: Smoke density acc. to DIN VDE 0482
MEGAFLEX 500, confer page 88 part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
Approved to UL/CSA (previously DIN VDE 0472 part 816)
see section N, page 398 Oil-resistant to DIN VDE 0473-811-404 /
DIN EN 60811-404
Hydrolysis resistant to DIN EN 61234-1
Ozone-resistant to DIN VDE 0473-811-403/
DIN EN 60811-403

Application
For fixed installation or flexible application that does not permanently recurring free movement without forced motion and without tensile stress, for
high mechanical strain. As a measuring and control cable e. g. in machine and plant engineering, air conditioning in the warehouse and materials
handling, shipbuilding and in the newable energies such as wind power stations.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13500 2 x 0,5 20 5,7 35,0 46,0 13508 8 G 0,5 20 8,5 80,0 116,0
13501 3 G 0,5 20 6,0 42,0 56,0 13509 10 G 0,5 20 9,3 94,0 135,0
13502 3 x 0,5 20 6,0 42,0 56,0 13510 12 G 0,5 20 9,6 108,0 158,0
13504 4 x 0,5 20 6,5 47,0 62,0 13511 16 G 0,5 20 10,7 129,0 210,0
13503 4 G 0,5 20 6,5 47,0 62,0 13512 18 G 0,5 20 11,2 145,0 216,0
13505 5 G 0,5 20 7,0 56,0 75,0 13514 20 G 0,5 20 11,9 172,0 240,0
13506 5 x 0,5 20 7,0 56,0 75,0 13515 25 G 0,5 20 13,4 240,0 315,0
13507 7 G 0,5 20 7,9 69,0 98,0

Continuation

98
Flexible Control Cables / Halogen-free Control Cables UL/CSA

MEGAFLEX 500-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, screened, EMC-preferred types, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
A
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13516 2 x 0,75 19 6,1 40,0 60,0 13562 2 x 2,5 14 8,3 96,0 132,0
13517 3 G 0,75 19 6,4 52,0 68,0 13563 3 G 2,5 14 9,0 144,0 168,0
13518 3 x 0,75 19 6,4 52,0 68,0 13565 4 G 2,5 14 9,8 148,0 195,0
13519 4 G 0,75 19 6,9 60,0 78,0 13566 5 G 2,5 14 10,9 181,0 256,0
13520 4 x 0,75 19 6,9 60,0 78,0 13567 7 G 2,5 14 12,9 255,0 345,0
13521 5 G 0,75 19 7,4 71,0 95,0 13568 8 G 2,5 17 13,8 285,0 390,0
13522 5 x 0,75 19 7,4 71,0 95,0 13569 10 G 2,5 14 15,8 340,0 482,0
13523 7 G 0,75 19 8,6 91,0 130,0 13570 12 G 2,5 14 15,9 441,0 572,0
13524 7 x 0,75 19 8,6 91,0 130,0 13571 2x4 12 9,8 120,0 220,0
13525 8 G 0,75 19 9,4 110,0 145,0 13572 3G4 12 10,6 174,0 251,0
13526 10 G 0,75 19 10,2 137,0 180,0 13573 4G4 12 11,5 230,0 305,0
13527 12 G 0,75 19 10,4 142,0 203,0 13574 5G4 12 12,7 273,0 388,0
13528 16 G 0,75 19 11,6 200,0 275,0 13575 7G4 12 13,9 316,0 504,0
13529 18 G 0,75 19 12,4 212,0 290,0 13576 2x6 10 11,5 173,0 270,0
13530 20 G 0,75 19 12,9 238,0 320,0 13577 3G6 10 12,4 240,0 351,0
13531 25 G 0,75 19 14,8 281,0 413,0 13578 4G6 10 13,8 305,0 464,0
13532 2x1 18 6,4 50,0 66,0 13579 5G6 10 15,7 439,0 546,0
13533 3G1 18 6,7 60,0 80,0 13580 7G6 10 16,6 505,0 670,0
13534 3x1 18 6,7 60,0 80,0 13581 2 x 10 8 14,9 255,0 461,0
13535 4G1 18 7,3 71,0 100,0 13582 3 G 10 8 15,9 350,0 574,0
13536 4x1 18 7,3 71,0 100,0 13583 4 G 10 8 17,8 535,0 785,0
13537 5G1 18 7,8 88,0 130,0 13584 5 G 10 8 19,6 592,0 914,0
13538 7G1 18 9,1 111,0 160,0 13585 7 G 10 8 21,6 810,0 1308,0
13539 8G1 18 9,9 127,0 197,0 13586 2 x 16 6 17,3 422,0 670,0
13540 10 G 1 18 10,8 150,0 232,0 13587 3 G 16 6 18,5 585,0 911,0
13541 12 G 1 18 11,2 184,0 260,0 13588 4 G 16 6 20,8 740,0 1105,0
13542 16 G 1 18 12,3 209,0 346,0 13589 5 G 16 6 22,9 895,0 1293,0
13543 18 G 1 18 13,2 260,0 382,0 13590 7 G 16 6 25,0 1282,0 2149,0
13544 20 G 1 18 13,8 317,0 440,0 13591 4 G 25 4 26,2 1140,0 1911,0
13545 25 G 1 18 15,8 349,0 540,0 13592 4 x 35 2 30,4 1576,0 2542,0
13546 2 x 1,5 16 7,0 63,0 88,0 13593 4 G 50 1 34,6 2155,0 3550,0
13547 3 G 1,5 16 7,3 80,0 100,0 13594 4 G 70 2/0 41,3 3120,0 4939,0
13548 3 x 1,5 16 7,3 80,0 100,0 13595 4 G 95 3/0 46,2 4043,0 6690,0
13549 4 G 1,5 16 7,9 97,0 125,0 13596 4 G 120 4/0 51,0 5069,0 8453,0
13550 5 G 1,5 16 8,6 119,0 158,0 13597 4 G 150 300 kcmil 59,0 5792,0 9104,0
13552 7 G 1,5 16 10,2 147,0 210,0
13554 8 G 1,5 16 11,1 170,0 244,0
13556 10 G 1,5 16 12,0 193,0 315,0
13557 12 G 1,5 16 12,5 267,0 340,0
13558 16 G 1,5 16 13,8 315,0 424,0
13559 18 G 1,5 16 15,0 374,0 480,0
13560 20 G 1,5 16 15,7 396,0 545,0
13561 25 G 1,5 16 18,0 526,0 702,0

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

99
Flexible Control Cables / Halogen-free Control Cables

JZ-600 HMH-C flexible control cable, halogen-free, extremely fire resistant, oil
resistant , 0,6/1kV, screened, EMC-preferred type, meter marking
1)

Technical data Cable structure Properties


Halogen-free, flexible control cable, Bare copper-conductor, to For critical applications recommend you
1)

core construction adapted to DIN VDE 0295 cl.5, fine-wire, request a consultation
DIN VDE 0285-525-2-51/ BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
DIN EN 50525-2-51 Core insulation of halogen-free polymer cadmium-free and contain no silicone
and DIN VDE 0285-525-3-11/ compound type TI6 to and free from substances harmful to
DIN EN 50525-3-11 DIN VDE 0207-363-7 / DIN EN 50363-7 the wetting properties of lacquers
Temperature range Core identification to DIN VDE 0293 Tests
flexing -15C to +70C black cores with continuous white Flame test acc. to
fixed -40C to +70C numbering DIN VDE 0482-332-3, BS 4066 part 3,
Nominal voltage U0/U 0,6/1 kV GN-YE conductor, 3 cores and above DIN EN 60332-3, IEC 60332-3 (previously
Test voltage 4000 V in the outer layer DIN VDE 0472 part 804 test method C)
Coupling resistance Cores stranded in layers with Self-extinguishing and flame-resistant
max. 250 Ohm/km optimal lay-length acc. to DIN VDE 0482 Part 265-2-1/
Minimum bending radius Inner sheath EN 50265-2-1/IEC 60332-1 (equivalent
flexing 15x cable Tinned copper braided screen, DIN VDE 0472 Part 804 test method B)
fixed installation 7,5x cable approx. 85% coverage Corrosiveness of corrosive gases
Radiation resistance Outer sheath of halogen-free polymer acc. to DIN VDE 0482 part 267,
up to 100x106 cJ/kg (up to 100 Mrad) compound type, TM7 to DIN EN 50267-2-2, IEC 607542
DIN VDE 0207-363-8 / DIN EN 50363-8 (equivalent DIN VDE 0472 part 813)
Sheath colour black (RAL 9005) Halogen-free acc. to DIN VDE 0482,
with meter marking Part 267, DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Note
G = with green-yellow conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-600 HMH, confer page 91

Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as in plant
installations, in heating and air-conditioning systems and steel production works. For fixed installation or flexible application, directed without forcing
by casual, constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the application in
dry, damp and wet environments, outdoors (fixed installation) and for laying on plaster. The dense screening assures interference-free transmission
of all signals and impulses.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12850 3 G 0,5 8,8 45,0 150,0 20 12864 3G1 9,8 64,0 163,0 18
12851 4 G 0,5 9,4 54,0 170,0 20 12865 4G1 10,4 76,0 200,0 18
12852 5 G 0,5 10,2 66,0 199,0 20 12866 5G1 11,4 89,0 239,0 18
12853 7 G 0,5 10,8 79,0 235,0 20 12867 7G1 12,3 114,0 289,0 18
12854 12 G 0,5 14,3 137,0 320,0 20 12868 12 G 1 15,9 186,0 464,0 18
12855 18 G 0,5 16,4 156,0 428,0 20 12869 18 G 1 18,2 284,0 628,0 18
12856 25 G 0,5 19,3 250,0 503,0 20 12870 25 G 1 22,0 387,0 855,0 18
12857 3 G 0,75 9,1 57,0 155,0 19 12871 3 G 1,5 10,8 82,0 187,0 16
12858 4 G 0,75 9,9 63,0 190,0 19 12872 4 G 1,5 11,5 99,0 240,0 16
12859 5 G 0,75 10,6 76,0 228,0 19 12873 5 G 1,5 13,0 123,0 289,0 16
12860 7 G 0,75 11,5 100,0 323,0 19 12874 7 G 1,5 14,2 148,0 383,0 16
12861 12 G 0,75 14,9 175,0 410,0 19 12875 12 G 1,5 18,4 274,0 592,0 16
12862 18 G 0,75 17,2 240,0 560,0 19 12876 18 G 1,5 21,3 386,0 806,0 16
12863 25 G 0,75 20,6 306,0 730,0 19 12877 25 G 1,5 25,4 531,0 1241,0 16

Continuation

100
Flexible Control Cables / Halogen-free Control Cables

JZ-600 HMH-C flexible control cable, halogen-free, extremely fire resistant, oil
resistant , 0,6/1kV, screened, EMC-preferred type, meter marking
1)

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12878 3 G 2,5 12,8 148,0 298,0 14 12894 4 G 16 25,7 807,0 1395,0 6
12879 4 G 2,5 13,8 169,0 345,0 14 12895 5 G 16 28,5 940,0 1870,0 6
12880 5 G 2,5 15,0 220,0 427,0 14 12896 7 G 16 31,4 1345,0 2720,0 6
12881 7 G 2,5 16,3 284,0 561,0 14 12897 3 G 25 28,2 920,0 2465,0 4
12882 12 G 2,5 21,6 470,0 857,0 14 12898 4 G 25 31,3 1169,0 2750,0 4
12883 18 G 2,5 25,2 572,0 1355,0 14 12899 5 G 25 34,5 1420,0 3490,0 4
12884 25 G 2,5 30,0 740,0 1995,0 14 12900 3 G 35 31,2 1250,0 3230,0 2
12885 3G4 14,6 178,0 391,0 12 12901 4 G 35 34,5 1680,0 4100,0 2
12886 4G4 15,7 234,0 527,0 12 12902 5 G 35 38,0 2020,0 4950,0 2
12887 5G4 17,2 284,0 700,0 12 12903 4 G 50 40,5 2370,0 5780,0 1
12888 3G6 15,9 245,0 629,0 10 12904 4 G 70 46,0 3257,0 7480,0 2/0
12889 4G6 17,4 316,0 731,0 10 12905 4 G 95 51,3 4060,0 10220,0 3/0
12890 5G6 19,2 442,0 1105,0 10 12906 4 G 120 56,4 5231,0 13750,0 4/0
12891 3 G 10 19,8 367,0 1125,0 8 12907 4 G 150 64,4 6794,0 15900,0 4/0
12892 4 G 10 21,5 549,0 1345,0 8
12893 5 G 10 23,5 604,0 1635,0 8

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

101
Flexible Control Cables / Halogen-free Control Cables

JB-750 HMH-C flexible control cable, coloured core, halogen-free, screened,


extremely fire resistant, oil resistant1), EMC-preferred type, meter marking

Technical data Cable structure Properties


Halogen-free core flexible control cable, Bare copper-conductor, to For the critical applications we advise for
1)

adapted to DIN VDE 0285-525-2-51 / DIN VDE 0295 cl.5, fine-wire, consultation
DIN EN 50525-2-51 and BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
DIN VDE 0285-525-3-11 / Core insulation of halogen-free polymer cadmium-free and contain no silicone
DIN EN 50525-3-11 compound type TI6 to and free from substances harmful to
Temperature range DIN VDE 0207-363-7 / DIN EN 50363-7 the wetting properties of lacquers
flexing -15C to +70C Core identification to DIN VDE 0293-308 Tests
fixed installation -40C to +70C GN-YE conductor Flame test acc. to
Nominal voltage U0/U 450/750 V Cores stranded in layers with DIN VDE 0482-332-3, BS 4066 part 3,
Test voltage 3000 V optimal lay-length DIN EN 60332-3, IEC 60332-3 (previously
Coupling resistance Separating foil DIN VDE 0472 part 804 test method C)
max. 250 Ohm/km Tinned copper braided screen, Self-extinguishing and flame retardant
Minimum bending radius approx. 85% coverage acc. to DIN VDE 0482-332-1-2,
flexing 12,5x cable Outer sheath of halogen-free polyner DIN EN 60332-1-2 / IEC 60332-1
fixed installation 4x cable compound type TM7 to (equivalent DIN VDE 0472 part 804
Radiation resistance DIN VDE 0207-363-8 / DIN EN 50363-8 test method B)
up to 100x106 cJ/kg (up to 100 Mrad) Sheath colour grey (RAL 7001) Corrosiveness of combustion gases
with meter marking acc. to DIN VDE 0482 part 267/
LS0H= Low Smoke Zero Halogen DIN EN 50267-2-2/ IEC 60754-2
(equivalent DIN VDE 0472 part 813)
Halogen-free acc. to DIN VDE 0482
part 267/DIN EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Note
G = with green-yellow conductor
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified" when
ordering.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JB-750 HMH, confer page 93

Application
Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts,
production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for
casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable
for use in dry, damp and wet environments and for installation on plaster An interference-free transmission of signals and pulse in assured by the high
degree of screening.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11942 3 G 1,5 8,4 80,0 125,0 16 11948 3G4 12,1 174,0 251,0 12
11943 4 G 1,5 9,3 97,0 160,0 16 11949 4G4 13,3 230,0 315,0 12
11944 5 G 1,5 10,2 119,0 193,0 16 11950 5G4 14,7 273,0 396,0 12
11945 3 G 2,5 9,9 144,0 198,0 14 11951 4G6 15,0 305,0 430,0 10
11946 4 G 2,5 11,0 148,0 240,0 14 11952 5G6 16,6 439,0 524,0 10
11947 5 G 2,5 12,2 181,0 280,0 14

Continuation

102
Flexible Control Cables / Halogen-free Control Cables

JB-750 HMH-C flexible control cable, coloured core, halogen-free, screened,


extremely fire resistant, oil resistant1), EMC-preferred type, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11953 4 G 10 18,9 535,0 804,0 8 11959 4 G 35 29,6 1576,0 2540,0 2
11954 5 G 10 21,1 592,0 942,0 8 11960 5 G 35 32,9 1930,0 3260,0 2
11955 4 G 16 21,9 740,0 1190,0 6 11961 4 G 50 35,3 2155,0 3668,0 1
11956 5 G 16 24,3 895,0 1370,0 6 11962 4 G 70 39,0 3120,0 5076,0 2/0
11957 4 G 25 27,0 1140,0 1968,0 4 11963 4 G 95 45,6 4043,0 6807,0 3/0
11958 5 G 25 30,0 1380,0 2514,0 4 11964 4 G 120 50,8 5069,0 8612,0 4/0

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

103
INHERENTLY SAFE PVC CONTROL CABLES
Flexible Control Cables / PVC Control Cables for Intrinsically Safe Circuits

OZ-BL outer sheath blue, intrinsic safety, flexible, meter marking


A

Technical data Cable structure Properties


Control cable, special PVC with blue outer Bare copper-conductor, to Extensively oil resistant,
sheath for hazardous areas to DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
hazard type -i- (= intrinsically safe) BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
For intrinsically safe installation acc. to Core insulation of special PVC The materials used in manufacture are
DIN EN 60079-14 and IEC 60079-14 compound type Z 7225 cadmium-free and contain no silicone
section 12.2.2 (VDE 0165 part 1) Core identification to DIN VDE 0293 and free from substances harmful to
Temperature range black cores with continuous white the wetting properties of lacquers
flexing -15C to +80C numbering Tests
fixed installation -40C to +80C without GN-YE conductor PVC self-extinguishing and flame retardant
Nominal voltage U0/U 300/500 V Cores stranded in layers with acc. to DIN VDE 0482-332-1-2,
Test voltage 3000 V optimal lay-length DIN EN 60332-1-2/IEC 60332-1 (equivalent
Breakdown voltage min. 6000 V Outer sheath of special PVC DIN VDE 0472 part 804 test method B)
Insulation resistance compound type TM2 to
min. 20 MOhm x km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 Note
Mutual capacitance Sheath colour blue (RAL 5015) For underground laying use NYY with blue
core/core approx. 120 nF/km with meter marking outer sheath.
Inductance AWG sizes are approximate equivalent
approx. 0,68 mH/km values. The actual cross-section is in mm.
Minimum bending radius Instrumentation cable RE-2Y(St)Yv with blue
flexing 7,5x cable outer sheath see Data and Computer Cables
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the requirements
for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Those cables are not suitable for
underground laying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
14001 2 x 0,75 5,3 14,4 46,0 19 14019 2 x 1,5 6,4 29,0 70,0 16
14002 3 x 0,75 5,6 21,6 54,0 19 14020 3 x 1,5 6,8 43,0 90,0 16
14003 4 x 0,75 6,3 29,0 66,0 19 14021 4 x 1,5 7,4 58,0 109,0 16
14004 5 x 0,75 6,9 36,0 80,0 19 14022 5 x 1,5 8,3 72,0 131,0 16
14075 7 x 0,75 7,5 52,0 110,0 19 14023 7 x 1,5 9,2 101,0 184,0 16
14005 8 x 0,75 8,3 58,0 130,0 19 14024 12 x 1,5 11,8 173,0 309,0 16
14076 12 x 0,75 9,8 88,0 179,0 19 14025 18 x 1,5 14,6 259,0 440,0 16
14006 18 x 0,75 12,2 130,0 257,0 19 14026 25 x 1,5 17,4 360,0 620,0 16
14007 25 x 0,75 14,3 180,0 365,0 19 14027 30 x 1,5 18,6 440,0 842,0 16
14008 30 x 0,75 15,3 215,0 448,0 19 14100 3 x 2,5 8,3 72,0 148,0 14
14009 34 x 0,75 16,5 245,0 510,0 19 14101 4 x 2,5 9,2 96,0 178,0 14
14010 41 x 0,75 18,1 298,0 607,0 19 14102 5 x 2,5 10,1 120,0 221,0 14
14011 2x1 5,6 19,0 60,0 18
14012 3x1 5,9 29,0 72,0 18
14013 4x1 6,6 38,0 86,0 18
14014 5x1 7,3 48,0 104,0 18
14015 7x1 8,1 67,0 141,0 18
14016 12 x 1 10,4 115,0 230,0 18
14017 18 x 1 12,9 173,0 343,0 18
14018 25 x 1 15,4 240,0 485,0 18

Dimensions and specifications may be changed without prior notice. (RA04)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA-EX
Cable Gland - HELUTOP HT-MS-EX-d

105
Flexible Control Cables / PVC Control Cables for Intrinsically Safe Circuits

OZ-BL-CY outer sheath blue, intrinsic safety, flexible, meter marking

Technical data Cable structure Properties


Control cable, special PVC with blue outer Bare copper-conductor, to Extensively oil resistant,
sheath for hazardous areas to DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
hazard type -i- (=intrinsically safe) BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
For intrinsically safe installation acc. to Core insulation of special PVC The materials used in manufacture are
DIN EN 60079-14 and IEC 60079-14 compound type Z 7225 cadmium-free and contain no silicone
section 12.2.2. (VDE 0165 part 1) Core identification to DIN VDE 0293 and free from substances harmful to
Temperature range black cores with continuous white the wetting properties of lacquers
flexing -10C to +80C numbering Tests
fixed installation -40C to +80C without GN-YE conductor PVC self-extinguishing and flame retardant
Nominal voltage U0/U 300/500 V Cores stranded in layers with acc. to DIN VDE 0482-332-1-2,
Test voltage 3000 V optimal lay-length DIN EN 60332-1-2 / IEC 60332-1
Breakdown voltage min. 6000 V Separating foil (equivalent DIN VDE 0472 part 804
Insulation resistance Tinned copper braided screen, test method B)
min. 20 MOhm x km approx. 85% coverage
Mutual capacitance Outer sheath of special PVC Note
core/core approx. 140 nF/km compound type TM2 to For underground laying use NYY with blue
core/screen approx. 187 nF/km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 outer sheath.
Inductance Sheath colour blue (RAL 5015) AWG sizes are approximate equivalent
approx. 0,68 mH/km with meter marking values. The actual cross-section is in mm.
Coupling resistance Instrumentation cable RE-2Y(St)Yv with blue
max. 250 Ohm/km outer sheath see Data and Computer cables
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the requirements
for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Those cables are not suitable for
underground laying. The copper braided screening ensures the transmission of data signals and free from interference.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
14028 2 x 0,75 6,1 40,0 59,0 19 14050 2 x 1,5 7,0 63,0 88,0 16
14029 3 x 0,75 6,3 52,0 66,0 19 14051 3 x 1,5 7,4 80,0 100,0 16
14030 4 x 0,75 6,8 60,0 77,0 19 14052 4 x 1,5 8,1 97,0 126,0 16
14031 5 x 0,75 7,4 71,0 93,0 19 14053 5 x 1,5 9,0 119,0 160,0 16
14088 7 x 0,75 8,2 91,0 130,0 19 14054 7 x 1,5 9,8 147,0 208,0 16
14032 8 x 0,75 9,0 110,0 145,0 19 14055 12 x 1,5 12,8 267,0 338,0 16
14033 10 x 0,75 10,3 137,0 180,0 19 14056 18 x 1,5 15,6 374,0 479,0 16
14034 12 x 0,75 10,5 142,0 202,0 19 14057 25 x 1,5 18,4 526,0 705,0 16
14035 18 x 0,75 12,7 212,0 292,0 19 14058 30 x 1,5 19,6 555,0 830,0 16
14036 20 x 0,75 13,6 238,0 362,0 19 14059 34 x 1,5 21,2 629,0 900,0 16
14037 25 x 0,75 15,0 281,0 415,0 19
14038 30 x 0,75 16,0 320,0 486,0 19
14039 34 x 0,75 17,2 345,0 523,0 19
14040 41 x 0,75 18,1 400,0 680,0 19
14041 2x1 6,4 50,0 65,0 18
14042 3x1 6,7 60,0 81,0 18
14043 4x1 7,2 71,0 98,0 18
14044 5x1 8,0 88,0 127,0 18
14045 7x1 8,7 111,0 158,0 18
14046 12 x 1 11,4 184,0 260,0 18
14047 18 x 1 13,6 260,0 380,0 18
14048 25 x 1 16,2 349,0 534,0 18
14049 34 x 1 18,5 486,0 741,0 18

Dimensions and specifications may be changed without prior notice. (RA04)

106
Flexible Control Cables / PVC Control Cables for Intrinsically Safe Circuits

OB-BL-PAAR-CY outer sheath blue, intrinsic safety, EMC-preferred type,


meter marking
A

Technical data Cable structure Properties


Special PVC control cable with blue outer Bare copper-conductor, to Extensively oil resistant,
sheath for hazardous areas to hazard DIN VDE 0295 cl.5, fine-wire, oil-/chemical resistance
type -i- for intrinsically safe installation BS 6360 cl.5, IEC 60228 cl.5 see table Technical Informations
acc. to DIN EN 60079-14 and Core insulation special PVC The materials used in manufacture are
IEC 60079-14 section 12.2.2. compound type TI2 to cadmium-free and contain no silicone
(VDE 0165 part 1) DIN VDE 0207-363-3 / DIN EN 50363-3 and free from substances harmful to
Conductor resistance Core identification (pair) to DIN 47100 the wetting properties of lacquers
at 0,5 mm 37,8 Ohm/km Cores twisted in pairs Tests
at 0,75 mm 25,3 Ohm/km Pairs stranded in layers with optimal PVC self-extinguishing and flame retardant
Temperature range lay-length acc. to DIN VDE 0482-332-1-2,
flexing -10C to +80C Separating foil DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation -30C to +80C Tinned copper braided screen, DIN VDE 0472 part 804 test method B)
Operating peak voltage approx. 85% coverage
(not for heavy current installation purposes) Outer sheath of special PVC Note
900 V compound type TM2 to AWG sizes are approximate equivalent
Test voltage DIN VDE 0207-363-4-1/DIN EN 50363-4-1 values. The actual cross-section is in mm.
core/core 2000 V Sheath colour blue (RAL 5015) Instrumentation cable RE-2Y(St)Yv with blue
core/screen 1000 V with meter marking outer sheath see Data and Computer Cables
Breakdown voltage min. 4000 V
Insulation resistance
min. 20 MOhm x km
Mutual capacitance
core/core approx. 105 nF/km
core/screen approx. 145 nF/km
Inductance
approx. 0,68 mH/km
Characteristic impedance
approx. 80 Ohm
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
For hazardous areas this flexible control cable has been constructed for closed circuit systems in accordance with VDE 0165 part 1, part 12. 2. 2. 6,
which covers the requirements for the special marking (blue) of this type (hazard type -i-). The paired construction and the copper screening afford
a good protection against electrical interference and ensure the transmission of data signals.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
14077 2 x 2 x 0,5 7,6 47,0 89,0 20 14089 2 x 2 x 0,75 8,6 60,0 105,0 19
14078 3 x 2 x 0,5 8,2 67,0 104,0 20 14090 3 x 2 x 0,75 9,1 80,0 128,0 19
14079 4 x 2 x 0,5 9,0 80,0 126,0 20 14091 4 x 2 x 0,75 10,1 110,0 156,0 19
14080 6 x 2 x 0,5 10,9 108,0 171,0 20 14092 6 x 2 x 0,75 12,4 142,0 216,0 19
14081 8 x 2 x 0,5 12,3 129,0 251,0 20 14093 8 x 2 x 0,75 14,2 200,0 309,0 19
14082 10 x 2 x 0,5 14,2 172,0 282,0 20 14094 10 x 2 x 0,75 16,0 238,0 355,0 19
14083 12 x 2 x 0,5 14,7 235,0 261,0 20 14095 12 x 2 x 0,75 16,8 270,0 405,0 19
14084 16 x 2 x 0,5 16,3 301,0 445,0 20 14096 16 x 2 x 0,75 18,6 342,0 560,0 19
14085 20 x 2 x 0,5 17,7 343,0 525,0 20 14097 20 x 2 x 0,75 21,2 369,0 671,0 19
14086 24 x 2 x 0,5 20,2 394,0 590,0 20 14098 24 x 2 x 0,75 22,8 451,0 795,0 19
14087 25 x 2 x 0,5 20,6 406,0 622,0 20 14099 25 x 2 x 0,75 23,2 461,0 803,0 19

Dimensions and specifications may be changed without prior notice. (RA04)

107
BIO-OIL & MICROBE-RESISTANT CABLES
Flexible Control Cables / Bio-Oil and microbial resistant Cables

BIOFLEX-500-JZ Bio-fuel resistant, abrasion resistant, recyclable environment


friendly, bio-oil resistant , meter marking1)

Technical data Cable structure Properties


Bio-oil resistant, abrasion resistant special Bare copper-conductor, to Resistant to
control cable in adapted to DIN VDE 0295 cl.5, fine-wire, Bio-fuel (diesel and petrol), highly resistant
DIN VDE 0285-525-1 / DIN EN 50525-1 BS 6360 cl.5, IEC 60228 cl.5 to biologically decomposable oils, Oxygene,
Temperature range Core insulation of special polymer Ozone, Hydrolysis and Microbes
flexing -20C to +80C Core identification to DIN VDE 0293 Low adhesion
fixed installation -40C to +80C black cores with continuous white
Nominal voltage U0/U 300/500 V numbering Note
Test voltage 3000 V GN-YE conductor, 3 cores and above G = with green-yellow conductor
Insulation resistance in the outer layer x = without green-yellow conductor (OZ)
min. 20 MOhm x km Cores stranded in layers with 1) For the critical applications we advise for
Minimum bending radius optimal lay-length consultation.
flexing 15x cable Outer sheath of special AWG sizes are approximate equivalent
fixed installation 4x cable polymer compound values. The actual cross-section is in mm.
Radiation resistance Sheath colour dark green screened analogue type:
up to 100x106 cJ/kg (up to 100 Mrad) with meter marking BIOFLEX-500-JZ-C, confer page 110

Application
HELUKABEL BIOFLEX-500-JZ is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance to
Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as in the steel industry
for difficult and problem areas. The high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25620 2 x 0,5 5,4 9,6 45,0 20 25654 2 x 1,5 7,2 29,0 68,0 16
25621 3 G 0,5 5,9 14,4 55,0 20 25655 3 G 1,5 7,6 43,0 87,0 16
25622 4 G 0,5 6,3 19,0 65,0 20 25656 4 G 1,5 8,2 58,0 106,0 16
25623 5 G 0,5 6,9 24,0 75,0 20 25657 5 G 1,5 9,0 72,0 131,0 16
25624 7 G 0,5 7,8 33,6 90,0 20 25658 7 G 1,5 10,7 101,0 173,0 16
25625 10 G 0,5 9,6 48,0 120,0 20 25659 10 G 1,5 13,0 144,0 245,0 16
25626 12 G 0,5 10,0 58,0 135,0 20 25660 12 G 1,5 13,4 173,0 293,0 16
25627 14 G 0,5 10,3 67,0 170,0 20 25661 14 G 1,5 14,5 202,0 347,0 16
25628 18 G 0,5 11,5 86,0 205,0 20 25662 18 G 1,5 16,0 259,0 454,0 16
25629 25 G 0,5 13,6 120,0 270,0 20 25663 25 G 1,5 19,5 360,0 641,0 16
25630 2 x 0,75 5,4 14,4 44,0 19 25664 42 G 1,5 23,8 605,0 1100,0 16
25631 3 G 0,75 6,2 21,6 53,0 19 25665 2 x 2,5 8,6 48,0 110,0 14
25632 4 G 0,75 6,7 29,0 64,0 19 25666 3 G 2,5 9,3 72,0 146,0 14
25633 5 G 0,75 7,3 36,0 76,0 19 25667 4 G 2,5 10,3 96,0 183,0 14
25634 7 G 0,75 8,8 50,0 96,0 19 25668 5 G 2,5 11,5 120,0 222,0 14
25635 10 G 0,75 10,5 72,0 140,0 19 25669 7 G 2,5 13,4 168,0 293,0 14
25636 12 G 0,75 11,0 86,0 170,0 19 25670 12 G 2,5 17,0 288,0 512,0 14
25637 14 G 0,75 11,4 101,0 202,0 19 25671 18 G 2,5 20,0 432,0 740,0 14
25638 18 G 0,75 12,6 130,0 260,0 19 25672 25 G 2,5 24,1 600,0 940,0 14
25639 25 G 0,75 15,2 180,0 282,0 19 25673 2x4 10,4 77,0 147,0 12
25640 41 G 0,75 18,0 296,0 600,0 19 25674 3G4 11,2 115,0 228,0 12
25641 42 G 0,75 18,5 310,0 620,0 19 25675 4G4 12,5 154,0 291,0 12
25642 2x1 6,6 19,0 53,0 18 25676 5G4 13,8 192,0 355,0 12
25643 3G1 7,0 29,0 63,0 18 25677 3G6 13,0 173,0 362,0 10
25644 4G1 7,6 38,0 75,0 18 25678 4G6 14,7 230,0 468,0 10
25645 5G1 8,2 48,0 89,0 18 25679 5G6 16,0 288,0 570,0 10
25646 7G1 9,6 67,0 115,0 18 25680 3 G 10 16,7 288,0 555,0 8
25647 10 G 1 11,6 96,0 166,0 18 25681 4 G 10 18,3 384,0 720,0 8
25648 12 G 1 12,0 115,0 201,0 18 25682 5 G 10 20,5 480,0 894,0 8
25649 14 G 1 13,2 134,0 230,0 18 25683 4 G 16 21,1 614,0 1063,0 6
25650 18 G 1 14,5 173,0 289,0 18 25684 5 G 16 23,6 768,0 1400,0 6
25651 25 G 1 17,6 240,0 380,0 18 25685 4 G 25 29,4 960,0 1590,0 4
25652 41 G 1 21,1 394,0 720,0 18 25686 4 G 35 32,8 1344,0 2200,0 2
25653 42 G 1 21,5 403,0 740,0 18 25687 4 G 50 38,9 1920,0 2400,0 1
25688 4 G 70 44,7 2688,0 4400,0 2/0
25689 4 G 95 59,6 3648,0 6000,0 3/0
25690 4 G 120 64,5 4608,0 7400,0 4/0

Dimensions and specifications may be changed without prior notice. (RA05)

109
Flexible Control Cables / Bio-Oil and microbial resistant Cables

BIOFLEX-500-JZ-C Bio-fuel resistant, abrasion resistant, recyclable environment


friendly, bio-oil resistant , Cu-screened, EMC-preferred type, meter marking
1)

Technical data Cable structure Properties


Bio-oil resistant, abrasion resistant special Bare copper-conductor, to Resistant to
control cable in adapted to DIN VDE 0295 cl.5, fine-wire, Bio-fuel (diesel and petrol), highly resistant
DIN VDE 0285-525-1 / DIN EN 50525-1 BS 6360 cl.5, IEC 60228 cl.5 to biologically decomposable oils, Oxygene,
Temperature range Core insualtion of special polymer Ozone, Hydrolysis and Microbes
flexing -20C to +80C Core identification to DIN VDE 0293 Low adhesion
fixed installation -40C to +80C black cores with continuous white
Nominal voltage U0/U 300/500 V numbering Note
Test voltage 3000 V GN-YE conductor, 3 cores and above G = with green-yellow conductor
Insulation resistance in the outer layer x = without green-yellow conductor (OZ)
min. 20 MOhm x km Cores stranded in layers with 1) For the critical applications we advise for
Coupling resistance optimal lay-length consultation.
max. 250 Ohm/km Special inner sheath AWG sizes are approximate equivalent
Minimum bending radius Tinned copper braided screen, values. The actual cross-section is in mm.
flexing 20x cable approx. 85% coverage unscreened analogue type:
fixed installation 6x cable Core wrapping of fleece BIOFLEX-500-JZ, confer page 109
Radiation resistance guarantees easy cable stripping
up to 100x106cJ/kg (up to 100 Mrad) Outer sheath of special
polymer compound
Sheath colour dark green
with meter marking

Application
HELUKABEL BIOFLEX-500-JZ-C is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance to
Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as in the steel industry
for difficult and problem areas. The inner sheaths of those cables raise the mecanical stress. The high flexibility of this cable type makes it quick and
easy to install. Suitable for outdoor lying. These screened cables are particularly suitable for the interference-free transmission in instrumentation and
control engineering applications (electromagnetic compatibillity). 1) For the critical applications we advise for consultation.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25691 2 x 0,5 6,6 41,0 68,0 20 25713 2x1 8,1 54,0 98,0 18
25692 3 G 0,5 7,1 45,0 84,0 20 25714 3G1 8,5 64,0 102,0 18
25693 4 G 0,5 7,6 54,0 95,0 20 25715 4G1 9,0 76,0 145,0 18
25694 5 G 0,5 8,2 66,0 107,0 20 25716 5G1 9,9 89,0 170,0 18
25695 7 G 0,5 9,4 79,0 135,0 20 25717 7G1 11,6 114,0 220,0 18
25696 10 G 0,5 11,2 107,0 170,0 20 25718 10 G 1 14,0 156,0 330,0 18
25697 12 G 0,5 11,3 137,0 195,0 20 25719 12 G 1 14,4 186,0 350,0 18
25698 14 G 0,5 11,9 142,0 222,0 20 25720 14 G 1 15,0 198,0 402,0 18
25699 18 G 0,5 12,9 156,0 278,0 20 25721 18 G 1 17,0 284,0 515,0 18
25700 25 G 0,5 15,9 250,0 406,0 20 25722 25 G 1 20,6 387,0 690,0 18
25701 2 x 0,75 7,2 46,0 88,0 19 25723 41 G 1 25,0 578,0 1070,0 18
25702 3 G 0,75 7,7 57,0 98,0 19 25724 42 G 1 25,5 590,0 1096,0 18
25703 4 G 0,75 8,2 63,0 112,0 19 25725 2 x 1,5 8,5 64,0 130,0 16
25704 5 G 0,75 8,8 76,0 130,0 19 25726 3 G 1,5 8,9 82,0 152,0 16
25705 7 G 0,75 10,1 100,0 185,0 19 25727 4 G 1,5 9,7 99,0 167,0 16
25706 10 G 0,75 12,2 140,0 270,0 19 25728 5 G 1,5 10,8 123,0 203,0 16
25707 12 G 0,75 12,3 175,0 294,0 19 25729 7 G 1,5 12,5 148,0 305,0 16
25708 14 G 0,75 13,0 190,0 317,0 19 25730 10 G 1,5 15,1 198,0 422,0 16
25709 18 G 0,75 14,6 240,0 357,0 19 25731 12 G 1,5 15,5 274,0 435,0 16
25710 25 G 0,75 17,8 306,0 510,0 19 25732 14 G 1,5 16,1 294,0 480,0 16
25711 41 G 0,75 21,5 403,0 951,0 19 25733 18 G 1,5 18,6 386,0 642,0 16
25712 42 G 0,75 22,0 410,0 975,0 19 25734 25 G 1,5 22,1 531,0 803,0 16

Continuation

110
Flexible Control Cables / Bio-Oil and microbial resistant Cables

BIOFLEX-500-JZ-C Bio-fuel resistant, abrasion resistant, recyclable environment


friendly, bio-oil resistant , Cu-screened, EMC-preferred type, meter marking
1)

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25735 41 G 1,5 27,2 840,0 1360,0 16 25748 4G6 17,0 316,0 560,0 10
25736 42 G 1,5 27,5 890,0 1375,0 16 25749 5G6 18,6 442,0 700,0 10
25737 2 x 2,5 10,6 110,0 180,0 14 25750 3 G 10 19,5 367,0 750,0 8
25738 3 G 2,5 11,1 148,0 215,0 14 25751 4 G 10 21,5 549,0 1023,0 8
25739 4 G 2,5 12,1 169,0 268,0 14 25752 5 G 10 23,9 604,0 1114,0 8
25740 5 G 2,5 13,2 220,0 349,0 14 25753 4 G 16 24,6 807,0 1385,0 6
25741 7 G 2,5 15,9 284,0 406,0 14 25754 5 G 16 27,3 940,0 1550,0 6
25742 12 G 2,5 19,5 470,0 720,0 14 25755 4 G 25 30,6 1169,0 1894,0 4
25743 2x4 12,6 124,0 300,0 12 25756 4 G 35 36,9 1680,0 2395,0 2
25744 3G4 13,4 178,0 340,0 12 25757 4 G 50 41,3 2370,0 3312,0 1
25745 4G4 15,0 234,0 408,0 12 25758 4 G 70 48,8 3257,0 4605,0 2/0
25746 5G4 16,4 284,0 504,0 12 25759 4 G 95 61,8 4060,0 6055,0 3/0
25747 3G6 15,2 245,0 453,0 10 25760 4 G 120 65,7 5231,0 7318,0 4/0

Dimensions and specifications may be changed without prior notice. (RA05)

111
Flexible Control Cables / microbial resistant Cables

KOMPOFLEX JZ-500 halogen-free, microbes resistant, low adhesion,


meter marking

Technical data Cable structure Properties


Microbes resistant, halogen-free special Tinned copper-conductor, to Resistant to
control cable in adapted to DIN VDE 0295 cl.5, fine-wire, UV-radiation, Oxygene, Ozone, Microbes,
DIN VDE 0285-525-2-51 / BS 6360 cl.5, IEC 60228 cl.5 Hydrofluoric acid, Hydrochloric acid and
DIN EN 50525-2-51 Core insulation of special thermoplastic diluted sulfuric acid
Temperature range polymer The materials used in manufacture are
flexing -30C to +90C Core identification to DIN VDE 0293 cadmium-free and contain no silicone
fixed installation -40C to +100C black cores with continuous white and free from substances harmful to
Nominal voltage U0/U 300/500 V numbering the wetting properties of lacquers
Test voltage 3000 V GN-YE conductor, 3 cores and above Low adhesion
Insulation resistance in the outer layer
min. 20 MOhm x km Cores stranded in layers with Note
Minimum bending radius optimal lay-length G = with green-yellow conductor
flexing 7,5x cable Outher sheath of special thermoplastic x = without green-yellow conductor (OZ)
fixed installation 4x cable polymer AWG sizes are approximate equivalent
Radiation resistance Sheath colour black (RAL 9005) values. The actual cross-section is in mm.
up to 100x106 cJ/kg (up to 100 Mrad) with meter marking screened analogue type:
KOMPOLEX JZ-500-C, confer page 113

Application
Extremly robust universal cable. This cable is specially installed in rubbish, sewage-treatment plants, composting works, animal stalls and greenhouses.
Suitable for installation for flexible use for medium mechanical, stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms as well as outside.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
26125 2 x 0,5 4,8 9,6 41,0 20 26168 3 G 1,5 6,7 43,0 79,0 16
26126 3 G 0,5 5,1 14,4 50,0 20 26169 4 G 1,5 7,3 58,0 98,0 16
26127 4 G 0,5 5,7 19,0 61,0 20 26170 5 G 1,5 8,2 72,0 112,0 16
26128 5 G 0,5 6,2 24,0 72,0 20 26171 7 G 1,5 9,8 101,0 159,0 16
26129 7 G 0,5 7,4 33,6 86,0 20 26172 12 G 1,5 12,1 173,0 280,0 16
26130 12 G 0,5 9,1 58,0 130,0 20 26173 18 G 1,5 14,5 259,0 420,0 16
26131 18 G 0,5 10,7 86,0 198,0 20 26174 20 G 1,5 15,2 288,0 480,0 16
26132 20 G 0,5 11,2 96,0 211,0 20 26175 25 G 1,5 17,8 360,0 604,0 16
26133 25 G 0,5 13,0 120,0 260,0 20 26176 34 G 1,5 19,8 490,0 812,0 16
26135 34 G 0,5 14,5 163,0 361,0 20 26177 42 G 1,5 21,4 605,0 1002,0 16
26136 42 G 0,5 15,8 202,0 405,0 20 26178 50 G 1,5 23,7 720,0 1240,0 16
26137 50 G 0,5 17,3 240,0 541,0 20 26179 61 G 1,5 25,3 878,0 1421,0 16
26138 61 G 0,5 19,4 293,0 670,0 20 26180 2 x 2,5 7,6 48,0 99,0 14
26139 2 x 0,75 5,2 14,4 42,0 19 26181 3 G 2,5 8,3 72,0 136,0 14
26140 3 G 0,75 5,5 21,6 49,0 19 26182 4 G 2,5 9,1 96,0 170,0 14
26141 4 G 0,75 6,2 29,0 60,0 19 26183 5 G 2,5 10,2 120,0 204,0 14
26142 5 G 0,75 6,8 36,0 71,0 19 26184 7 G 2,5 12,1 168,0 281,0 14
26143 7 G 0,75 8,1 50,0 88,0 19 26185 12 G 2,5 15,2 288,0 487,0 14
26144 12 G 0,75 9,9 86,0 161,0 19 26186 18 G 2,5 18,1 432,0 704,0 14
26145 18 G 0,75 11,9 130,0 250,0 19 26187 25 G 2,5 22,2 600,0 909,0 14
26146 20 G 0,75 12,6 144,0 266,0 19 26189 3G4 9,9 115,0 224,0 12
26147 25 G 0,75 14,5 180,0 273,0 19 26190 4G4 11,0 154,0 289,0 12
26149 34 G 0,75 16,4 245,0 501,0 19 26191 5G4 12,1 192,0 357,0 12
26150 42 G 0,75 17,6 302,0 591,0 19 26192 7G4 13,3 269,0 451,0 12
26151 50 G 0,75 19,8 360,0 712,0 19 26193 12 G 4 18,3 461,0 782,0 12
26152 61 G 0,75 20,9 439,0 820,0 19 26195 3G6 11,7 173,0 345,0 10
26153 2x1 5,5 19,0 48,0 18 26196 4G6 13,0 230,0 417,0 10
26154 3G1 6,0 29,0 56,0 18 26197 5G6 14,5 288,0 521,0 10
26155 4G1 6,6 38,0 70,0 18 26198 7G6 16,0 403,0 622,0 10
26156 5G1 7,2 48,0 81,0 18 26199 3 G 10 15,0 288,0 537,0 8
26157 7G1 8,6 67,0 109,0 18 26200 4 G 10 16,8 384,0 699,0 8
26158 12 G 1 10,7 115,0 191,0 18 26201 5 G 10 18,7 480,0 851,0 8
26159 18 G 1 12,7 173,0 274,0 18 26202 7 G 10 20,6 672,0 1102,0 8
26160 20 G 1 13,5 192,0 314,0 18 26204 4 G 16 19,7 614,0 1028,0 6
26162 30 G 1 16,0 288,0 492,0 18 26206 7 G 16 24,4 1075,0 1772,0 6
26163 34 G 1 17,4 326,0 640,0 18 26208 4 G 25 25,2 960,0 1577,0 4
26164 42 G 1 18,9 403,0 804,0 18 26212 4 G 35 29,0 1344,0 2097,0 2
26165 50 G 1 21,0 480,0 932,0 18 26215 4 G 50 33,4 1920,0 2914,0 1
26166 61 G 1 22,2 586,0 1102,0 18 26216 5 G 50 37,2 2400,0 3919,0 1
26167 2 x 1,5 6,3 29,0 60,0 16

Dimensions and specifications may be changed without prior notice. (RA05)

112
Flexible Control Cables / microbial resistant Cables

KOMPOFLEX JZ-500-C halogen-free, microbes resistant, Cu-screened,


EMC-preferred type, meter marking
A

Technical data Cable structure Properties


Screened microbes resistant, halogen-free Tinned copper-conductor, to Resistant to
special control cable in adapted to DIN VDE 0295 cl.5, fine-wire, UV-radiation, Oxygene, Ozone, Microbes,
DIN VDE 0285-525-2-51/ BS 6360 cl.5, IEC 60228 cl.5 Hydrofluoric acid, Hydrochloric acid and
DIN EN 50525-2-51 Core insulation of special thermoplastic diluted sulfuric acid
Temperature range polymer Low adhesion
flexing -30C to +90C Core identification to DIN VDE 0293 The materials used in manufacture are
fixed installation -40C to +100C black cores with continuous white cadmium-free and contain no silicone
Nominal voltage U0/U 300/500 V numbering and free from substances harmful to
Test voltage GN-YE conductor, 3 cores and above the wetting properties of lacquers
core/core 4000 V in the outer layer
core/screen 2000 V Cores stranded in layers with Note
Insulation resistance optimal lay-length G = with green-yellow conductor
min. 20 MOhm x km Inner sheath of special thermoplastic x = without green-yellow conductor (OZ)
Coupling resistance polymer AWG sizes are approximate equivalen
max. 250 Ohm/km Tinned copper braided screen, values. The actual cross-section is in mm.
Minimum bending radius approx. 85% coverage unscreened analogue type:
flexing 7,5x cable Core wrapping of fleece KOMPOFLEX JZ-500, confer page 112
fixed installation 4x cable guarantees easy cable stripping
Radiation resistance Outer sheath of special thermoplastic
up to 100x106 cJ/kg (up to 100 Mrad) polymer
Sheath colour black (RAL 9005)
with meter marking

Application
Extremly robust universal cable. This cable is specially installed in rubbish, sewage-treatment plants, composting works, animal stalls and greenhouses.
The inner sheaths of those cables raise the mechanical stress. Suitable for installation for flexible use for medium mechanical, stresses with free
movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside. The high flexibility of this cable type makes it
quick and easy to install. This screened cable is ideal for use in data signal transmission free from interferences for measurement and control engineering
technology.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
26217 2 x 0,5 6,9 41,0 68,0 20 26245 2x1 7,9 54,0 98,0 18
26218 3 G 0,5 7,2 45,0 84,0 20 26246 3G1 8,2 64,0 102,0 18
26219 4 G 0,5 7,8 54,0 95,0 20 26247 4G1 8,9 76,0 145,0 18
26220 5 G 0,5 8,3 66,0 107,0 20 26248 5G1 9,5 89,0 171,0 18
26221 7 G 0,5 9,5 79,0 135,0 20 26249 7G1 11,0 114,0 210,0 18
26222 12 G 0,5 11,3 137,0 195,0 20 26250 12 G 1 13,1 186,0 330,0 18
26223 18 G 0,5 13,1 156,0 278,0 20 26251 18 G 1 15,4 284,0 488,0 18
26224 20 G 0,5 13,8 173,0 310,0 20 26252 20 G 1 16,0 325,0 545,0 18
26225 25 G 0,5 15,7 250,0 406,0 20 26253 25 G 1 18,3 387,0 690,0 18
26226 30 G 0,5 16,0 297,0 520,0 20 26254 30 G 1 18,8 457,0 770,0 18
26227 34 G 0,5 17,4 316,0 571,0 20 26255 34 G 1 20,3 500,0 811,0 18
26228 42 G 0,5 18,9 360,0 651,0 20 26256 42 G 1 21,8 590,0 996,0 18
26229 50 G 0,5 20,9 407,0 760,0 20 26257 50 G 1 24,0 681,0 1320,0 18
26230 61 G 0,5 22,9 520,0 911,0 20 26258 61 G 1 26,2 710,0 1480,0 18
26231 2 x 0,75 7,6 46,0 88,0 19 26259 2 x 1,5 8,4 64,0 130,0 16
26232 3 G 0,75 7,8 57,0 98,0 19 26260 3 G 1,5 9,0 82,0 154,0 16
26233 4 G 0,75 8,3 63,0 112,0 19 26261 4 G 1,5 9,6 99,0 165,0 16
26234 5 G 0,75 9,1 76,0 130,0 19 26262 5 G 1,5 10,5 123,0 197,0 16
26235 7 G 0,75 10,4 100,0 185,0 19 26263 7 G 1,5 12,1 148,0 305,0 16
26236 12 G 0,75 12,5 175,0 294,0 19 26264 12 G 1,5 14,9 274,0 435,0 16
26237 18 G 0,75 14,3 240,0 357,0 19 26265 18 G 1,5 17,1 386,0 642,0 16
26238 20 G 0,75 15,2 262,0 404,0 19 26266 20 G 1,5 18,0 401,0 718,0 16
26239 25 G 0,75 17,6 306,0 510,0 19 26267 25 G 1,5 20,7 531,0 803,0 16
26240 30 G 0,75 18,1 340,0 561,0 19 26268 30 G 1,5 21,1 598,0 961,0 16
26241 34 G 0,75 19,5 346,0 670,0 19 26269 34 G 1,5 22,7 671,0 1060,0 16
26242 42 G 0,75 20,9 410,0 960,0 19 26270 42 G 1,5 24,4 890,0 1300,0 16
26243 50 G 0,75 23,2 470,0 1104,0 19 26271 50 G 1,5 26,8 997,0 1677,0 16
26244 61 G 0,75 25,0 550,0 1270,0 19 26272 61 G 1,5 29,6 1120,0 1971,0 16

Continuation

113
Flexible Control Cables / microbial resistant Cables

KOMPOFLEX JZ-500-C halogen-free, microbes resistant, Cu-screened,


EMC-preferred type, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
26273 2 x 2,5 10,0 110,0 180,0 14 26292 3 G 10 17,8 367,0 730,0 8
26274 3 G 2,5 10,7 148,0 215,0 14 26293 4 G 10 19,7 549,0 1004,0 8
26275 4 G 2,5 11,4 169,0 268,0 14 26294 5 G 10 21,6 604,0 1170,0 8
26276 5 G 2,5 12,5 220,0 349,0 14 26295 7 G 10 24,0 820,0 1405,0 8
26277 7 G 2,5 15,0 284,0 404,0 14 26296 3 G 16 20,7 653,0 894,0 6
26278 12 G 2,5 18,0 470,0 710,0 14 26297 4 G 16 22,6 807,0 1311,0 6
26279 18 G 2,5 21,2 572,0 891,0 14 26298 5 G 16 25,2 940,0 1550,0 6
26280 25 G 2,5 25,5 740,0 1104,0 14 26299 7 G 16 27,6 1345,0 1820,0 6
26281 2x4 11,6 124,0 300,0 12 26300 3 G 25 26,0 920,0 1430,0 4
26282 3G4 12,3 178,0 340,0 12 26301 4 G 25 28,9 1169,0 1894,0 4
26283 4G4 13,4 234,0 408,0 12 26302 5 G 25 31,8 1420,0 2272,0 4
26284 5G4 14,8 284,0 504,0 12 26303 4 G 35 33,4 1680,0 2310,0 2
26285 7G4 16,2 321,0 640,0 12 26304 5 G 35 37,2 2020,0 2740,0 2
26286 12 G 4 21,8 581,0 894,0 12 26305 4 G 50 38,2 2370,0 3270,0 1
26287 2x6 13,5 176,0 391,0 10 26306 5 G 50 43,0 2880,0 4080,0 1
26288 3G6 14,2 245,0 453,0 10
26289 4G6 15,6 316,0 560,0 10
26290 5G6 17,0 442,0 680,0 10
26291 7G6 18,7 530,0 891,0 10

Dimensions and specifications may be changed without prior notice. (RA05)

114
HYGIENIC CABLE
Flexible Control Cables / Hygienic Cables

NANOFLEX HC*500 cut-resistant, meter marking

Technical data Cable structure Properties


Special PUR sheathed cable Bare copper-conductor, to Resistant to UV radiation, Oxygen,
acc. to DIN VDE 0285-525-1 / DIN VDE 0295 cl.5, fine-wire, Ozone, Hydrolysis, Microbes
DIN EN 50525-1 BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
Temperature range Core insulation of special PVC cadmium-free and contain no silicone
flexing -5C to +80C compound type TI2 to and free from substances harmful to
fixed installation -40C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 the wetting properties of lacquers
Nominal voltage U0/U 300/500 V Core identification to DIN VDE 0293 Good cleaning properties
Test voltage 4000 V black cores with continuous white Resistent to all standard detergents
Breakdown voltage min. 8000 V numbering
Insulation resistance GN-YE conductor, 3 cores and above Note
min. 20 MOhm x km in the outer layer G = with green-yellow conductor
Minimum bending radius Cores stranded in layers with x = without green-yellow conductor (OZ)
flexing 7,5x cable optimal lay-length AWG sizes are approximate equivalent
fixed installation 4x cable Outer sheath of special full-polyurethane values. The actual cross-section is in mm.
Radiation resistance compound type TMPU to screened analogue type:
up to 100x106 cJ/kg (up to 100 Mrad) DIN EN 50363-10-2 NANOFLEXHC 500-C, confer page 117
Sheath colour light grey (RAL 7035) *Hygienic Cable
with meter marking

Application
Special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications in which
food and beverages are processed unpacked and unsealed, e. g. processing of dairy products, meat, fish; production of convenience foods, brewery
and beverage industry.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
27031 2 x 0,5 4,8 10,0 45,0 20 27061 4x1 6,6 38,0 75,0 18
27032 3 G 0,5 5,1 14,0 55,0 20 27062 5G1 7,3 48,0 89,0 18
27033 3 x 0,5 5,1 14,0 55,0 20 27063 5x1 7,3 48,0 89,0 18
27034 4 G 0,5 5,5 19,0 65,0 20 27064 7G1 8,1 67,0 115,0 18
27035 4 x 0,5 5,5 19,0 65,0 20 27065 7x1 8,1 67,0 115,0 18
27036 5 G 0,5 6,2 24,0 75,0 20 27066 10 G 1 9,8 96,0 166,0 18
27037 5 x 0,5 6,2 24,0 75,0 20 27067 12 G 1 10,4 115,0 201,0 18
27038 7 G 0,5 7,2 34,0 90,0 20 27068 18 G 1 12,9 173,0 289,0 18
27039 7 x 0,5 7,2 34,0 90,0 20 27069 25 G 1 15,4 240,0 380,0 18
27040 10 G 0,5 8,3 48,0 120,0 20 27070 2 x 1,5 6,4 29,0 68,0 16
27041 12 G 0,5 8,7 58,0 135,0 20 27071 3 G 1,5 6,8 43,0 87,0 16
27042 18 G 0,5 10,7 86,0 205,0 20 27072 3 x 1,5 6,8 43,0 87,0 16
27043 25 G 0,5 12,6 120,0 270,0 20 27073 4 G 1,5 7,4 58,0 106,0 16
27044 2 G 0,75 5,3 14,0 44,0 19 27074 4 x 1,5 7,4 58,0 106,0 16
27045 3 G 0,75 5,6 22,0 53,0 19 27075 5 G 1,5 8,3 72,0 131,0 16
27046 3 G 0,75 5,6 22,0 53,0 19 27076 5 x 1,5 8,3 72,0 131,0 16
27047 4 G 0,75 6,3 29,0 64,0 19 27077 7 G 1,5 10,9 101,0 173,0 16
27048 4 x 0,75 6,3 29,0 64,0 19 27078 7 x 1,5 10,9 101,0 173,0 16
27049 5 G 0,75 6,9 36,0 76,0 19 27079 12 G 1,5 11,8 173,0 293,0 16
27050 5 x 0,75 6,9 36,0 76,0 19 27080 18 G 1,5 14,6 259,0 454,0 16
27051 7 G 0,75 7,5 50,0 96,0 19 27081 25 G 1,5 17,4 360,0 641,0 16
27052 7 x 0,75 7,5 50,0 96,0 19 27082 2 x 2,5 7,8 48,0 110,0 14
27053 10 G 0,75 9,2 72,0 140,0 19 27083 3 G 2,5 8,3 72,0 146,0 14
27054 12 G 0,75 9,8 86,0 170,0 19 27084 4 G 2,5 9,2 96,0 183,0 14
27055 18 G 0,75 12,2 130,0 260,0 19 27085 5 G 2,5 10,1 120,0 222,0 14
27056 25 G 0,75 14,3 180,0 282,0 19 27086 7 G 2,5 11,2 168,0 293,0 14
27057 2x1 5,6 19,0 53,0 18 27087 12 G 2,5 14,8 288,0 512,0 14
27058 3G1 5,9 29,0 63,0 18 27088 4G4 10,9 154,0 291,0 12
27059 3x1 5,9 29,0 63,0 18 27089 5G4 12,1 192,0 355,0 12
27060 4G1 6,6 38,0 75,0 18

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-Clean

116
Flexible Control Cables / Hygienic Cables

NANOFLEX HC*500-C EMC preferred type, cut-resistant, screened, no


inner sheath, meter marking
A

Technical data Cable structure Properties


Special PUR sheated cable Bare copper-conductor, to Resistant to UV radiation, Oxygen,
adapted to DIN VDE 0285-525-1 / DIN VDE 0295 cl.5, fine-wire, Ozone, Hydrolysis, Microbes
DIN EN 50525-1 BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
Temperature range Core insulation special PVC cadmium-free and contain no silicone
flexing -5C to +80C compound type TI2 to and free from substances harmful to
fixed installation -40C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 the wetting properties of lacquers
Nominal voltage U0/U 300/500 V Core identification to DIN VDE 0293 Good cleaning properties
Test voltage 3000 V black cores with continuous white Resistent to all standard detergents
Breakdown voltage min. 6000 V numbering
Insulation resistance GN-YE conductor, 3 cores and above Note
Min. 20 MOhm x km in the outer layer G = with green-yellow conductor
Coupling resistance Cores stranded in layers with x = without green-yellow conductor (OZ)
max. 250 Ohm/km optimal lay-length AWG sizes are approximate equivalent
Minimum bending radius Separating foil values. The actual cross-section is in mm.
flexing 10x cable Tinned copper braided screen, Unscreened analogue type:
fixed installation 5x cable approx. 85% coverage NANOFLEX HC 500, confer page 116
Radiation resistance Outer sheath of special full-polyurethane *Hygienic Cable
up to 100x106 cJ/kg (up to 100 Mrad) compound type TMPU to
DIN EN 50363-10-2
Sheath colour light grey (RAL 7035)
With meter marking

Application
Screened special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications
in which food and beverages are processed unpacked and unsealed, e. g. processing of dairy products, meat, fish; production of convenience foods,
brewery and beverage industry.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
27105 2 x 0,5 5,7 35,0 47,0 20 27135 4G1 7,2 71,0 100,0 18
27107 3 G 0,5 5,9 42,0 57,0 20 27136 5x1 8,0 88,0 128,0 18
27106 3 x 0,5 5,9 42,0 57,0 20 27137 5G1 8,0 88,0 128,0 18
27108 4 G 0,5 6,4 47,0 60,0 20 27138 7x1 8,7 111,0 157,0 18
27109 4 x 0,5 6,4 47,0 60,0 20 27139 7G1 8,7 111,0 157,0 18
27110 5 x 0,5 6,9 56,0 75,0 20 27140 10 G 1 11,2 150,0 230,0 18
27111 5 G 0,5 6,9 56,0 75,0 20 27141 12 G 1 11,4 184,0 262,0 18
27112 7 G 0,5 7,6 69,0 97,0 20 27142 18 G 1 13,6 260,0 381,0 18
27113 7 x 0,5 7,6 69,0 97,0 20 27143 25 G 1 16,2 349,0 535,0 18
27114 10 G 0,5 9,6 94,0 133,0 20 27144 2 x 1,5 7,0 63,0 87,0 16
27115 12 G 0,5 9,7 108,0 158,0 20 27145 3 x 1,5 7,4 80,0 102,0 16
27116 18 G 0,5 11,5 145,0 218,0 20 27146 3 G 1,5 7,4 80,0 102,0 16
27117 25 G 0,5 13,7 240,0 315,0 20 27147 4 x 1,5 8,1 97,0 127,0 16
27118 2 x 0,75 6,1 40,0 60,0 19 27148 4 G 1,5 8,1 97,0 127,0 16
27119 3 x 0,75 6,3 52,0 67,0 19 27149 5 x 1,5 9,0 119,0 159,0 16
27120 3 G 0,75 6,3 52,0 67,0 19 27150 5 G 1,5 9,0 119,0 159,0 16
27121 4 G 0,75 6,8 60,0 76,0 19 27151 7 x 1,5 9,8 147,0 207,0 16
27122 4 x 0,75 6,8 60,0 76,0 19 27152 7 G 1,5 9,8 147,0 207,0 16
27123 5 x 0,75 7,4 71,0 92,0 19 27153 12 G 1,5 12,8 267,0 340,0 16
27124 5 G 0,75 7,4 71,0 92,0 19 27154 18 G 1,5 15,6 374,0 480,0 16
27125 7 G 0,75 8,2 91,0 131,0 19 27155 25 G 1,5 18,4 526,0 704,0 16
27126 7 x 0,75 8,2 91,0 131,0 19 27156 2 x 2,5 8,4 96,0 131,0 14
27127 10 G 0,75 10,3 137,0 180,0 19 27157 3 G 2,5 8,8 144,0 168,0 14
27128 12 G 0,75 10,5 142,0 204,0 19 27158 4 G 2,5 9,8 148,0 194,0 14
27129 18 G 0,75 12,7 212,0 290,0 19 27159 5 G 2,5 10,8 181,0 222,0 14
27130 25 G 0,75 15,0 281,0 413,0 19 27160 7 G 2,5 11,9 255,0 345,0 14
27131 2x1 6,4 50,0 66,0 18 27161 12 G 2,5 15,8 441,0 570,0 14
27132 3G1 6,7 60,0 82,0 18 27162 4G4 11,6 230,0 310,0 12
27133 3x1 6,7 60,0 82,0 18 27163 5G4 12,8 273,0 386,0 12
27134 4x1 7,2 71,0 100,0 18

Dimensions and specifications may be changed without prior notice. (RA02)

117
Flexible Control Cables / Hygienic Cables

NANOFLEX HC*TRONIC flexible, colour code to DIN 47100, meter


marking

Technical data Cable structure Properties


Special-PUR data cable Bare copper-conductor, from 0,5 mm to Resistant to UV radiation, oxygen, ozone,
adapted to DIN VDE 0812 DIN VDE 0295 cl.5, fine-wire, hydrolysis, microbes
Temperature range BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
flexing -5C to +80C Conductor construction: cadmium-free and contain no silicone
fixed installation -40C to +80C 0,14 mm = 18x0,1 mm and free from substances harmful to
Peak operating voltage 0,25 mm = 14x0,15 mm the wetting properties of lacquers
(not for purposes of high current and 0,34 mm = 7x0,25 mm Good cleaning properties
power installation) Core insulation of special PVC Resistant to all standard detergents
0,14 mm = 350 V compound type TI2 to
0,25 mm = 500 V DIN VDE 0207-363-3 / DIN EN 50363-3 Note
Test voltage Core identification to DIN 47100, Screened analogue type:
up to 0,25 mm 1200 V without colour repetition NANOFLEXHC TRONIC-C, confer page 120
from 0,34 mm 2000 V Cores stranded in layers with *Hygienic Cable
Breakdown voltage optimal lay-lengths
up to 0,25 mm 2400 V Outer sheath of special full polyurethane
from 0,34 mm 4000 V compound type TMPU to
Insulation resistance DIN EN 50363-10-2
min. 20 MOhm x km Sheath colour light grey (RAL 7035)
Operating capacity with meter marking
(approx. value) at 800 Hz
0,14 mm 120 pF/m
0,25 mm 150 pF/m
Inductance
approx. 0,65 mH/km
Impedance
approx. 78 Ohm
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Application
Special PUR data cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications
in which food and beverages are processed unpacked and unsealed, e. g. processing of dairy products, meat, fish; production of convenience foods,
brewery and beverage industry.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
27164 2 x 0,14 3,5 3,0 13,0 26 27180 2 x 0,25 3,8 5,0 18,0 24
27165 3 x 0,14 3,7 4,0 16,0 26 27181 3 x 0,25 4,0 7,0 22,0 24
27166 4 x 0,14 3,9 5,0 19,0 26 27182 4 x 0,25 4,3 10,0 26,0 24
27167 5 x 0,14 4,3 7,0 22,0 26 27183 5 x 0,25 4,7 12,0 30,0 24
27168 6 x 0,14 4,6 8,0 25,0 26 27184 6 x 0,25 5,3 14,0 36,0 24
27169 7 x 0,14 4,6 9,0 28,0 26 27185 7 x 0,25 5,3 17,0 42,0 24
27170 8 x 0,14 5,5 11,0 35,0 26 27186 8 x 0,25 6,1 19,0 49,0 24
27171 10 x 0,14 5,9 13,0 41,0 26 27187 10 x 0,25 6,8 24,0 57,0 24
27172 12 x 0,14 6,1 16,0 48,0 26 27188 12 x 0,25 7,0 29,0 66,0 24
27173 14 x 0,14 6,3 19,0 53,0 26 27189 14 x 0,25 7,3 34,0 75,0 24
27174 16 x 0,14 6,9 22,0 59,0 26 27190 16 x 0,25 7,7 38,0 84,0 24
27175 18 x 0,14 7,2 24,0 65,0 26 27191 18 x 0,25 8,3 43,0 72,0 24
27176 20 x 0,14 7,5 27,0 70,0 26 27192 19 x 0,25 8,3 46,0 84,0 24
27177 21 x 0,14 7,6 28,0 77,0 26 27193 20 x 0,25 8,7 48,0 101,0 24
27178 24 x 0,14 8,5 32,0 87,0 26 27194 21 x 0,25 8,8 50,0 107,0 24
27179 25 x 0,14 8,6 34,0 91,0 26 27195 24 x 0,25 9,8 60,0 120,0 24
27196 25 x 0,25 10,0 61,0 132,0 24

Continuation

118
Flexible Control Cables / Hygienic Cables

NANOFLEX HC*TRONIC flexible, colour code to DIN 47100, meter


marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
27197 2 x 0,34 4,2 7,0 22,0 22 27218 7 x 0,5 6,8 34,0 81,0 20
27198 3 x 0,34 4,4 10,0 30,0 22 27219 8 x 0,5 7,8 38,0 97,0 20
27199 4 x 0,34 4,8 13,0 43,0 22 27220 10 x 0,5 8,7 48,0 116,0 20
27200 5 x 0,34 5,4 16,0 54,0 22 27221 12 x 0,5 8,9 58,0 135,0 20
27201 6 x 0,34 5,9 20,0 58,0 22 27222 16 x 0,5 10,0 77,0 168,0 20
27202 7 x 0,34 5,9 23,0 61,0 22 27223 20 x 0,5 11,2 96,0 213,0 20
27203 8 x 0,34 7,1 26,0 73,0 22 27224 24 x 0,5 12,7 116,0 241,0 20
27204 10 x 0,34 7,6 33,0 82,0 22 27225 2 x 0,75 5,2 14,0 47,0 19
27205 12 x 0,34 7,8 39,0 102,0 22 27226 3 x 0,75 5,5 22,0 54,0 19
27206 14 x 0,34 8,4 46,0 108,0 22 27227 4 x 0,75 6,0 29,0 66,0 19
27207 16 x 0,34 8,8 52,0 126,0 22 27228 5 x 0,75 6,7 36,0 80,0 19
27208 18 x 0,34 9,3 59,0 143,0 22 27229 7 x 0,75 7,4 50,0 110,0 18
27209 20 x 0,34 1,0 65,0 160,0 22 27230 8 x 0,75 8,7 58,0 125,0 19
27210 21 x 0,34 10,1 69,0 166,0 22 27231 10 x 0,75 9,6 72,0 148,0 19
27211 24 x 0,34 11,2 78,0 186,0 22 27232 12 x 0,75 9,9 86,0 176,0 19
27212 25 x 0,34 11,4 82,0 192,0 22 27233 16 x 0,75 11,1 115,0 220,0 19
27213 2 x 0,5 4,6 10,0 40,0 20 27234 20 x 0,75 12,5 144,0 276,0 19
27214 3 x 0,5 4,9 14,0 46,0 20
27215 4 x 0,5 5,5 19,0 55,0 20
27216 5 x 0,5 6,0 24,0 64,0 20
27217 6 x 0,5 6,8 29,0 73,0 20

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-Clean

119
Flexible Control Cables / Hygienic Cables

NANOFLEX HC*TRONIC-C EMC preferred type, flexible, colour code


to DIN 47100, screened, meter marking

Technical data Cable structure Properties


Special-PUR data cable for electronic Bare copper-conductor, from 0,5 mm to Resistant to UV radiation, oxygen, ozone,
control adapted to DIN VDE 0812 DIN VDE 0295 cl.5, fine-wire, hydrolysis, microbes
Temperature range BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
flexing -5C to +80C Conductor construction: cadmium-free and contain no silicone
fixed installation -40C to +80C 0,14 mm = 18x0,1 mm and free from substances harmful to the
Peak operating voltage 0,25 mm = 14x0,15 mm wetting properties of lacquers
(not for purposes of high current and power 0,34 mm = 7x0,25 mm Good cleaning properties
installation) Core insulation of special PVC Resistant to all standard detergents
0,14 mm = 350 V compound type TI2 to
0,25 mm = 500 V DIN VDE 0207-363-3 / DIN EN 50363-3 Note
Test voltage Core identification to DIN 47100, AWG sizes are approximate equivalent
core/core 1200 V without colour repetition values. The actual cross-section is in mm.
core/screen 800 V Cores stranded in layers with unscreened analogue type:
Breakdown voltage optimal lay-length NANOFLEXHC TRONIC, confer page 118
min. 2400 V Separating foil *Hygienic Cable
Insulation resistance Drain stranded wire, tinned copper
min. 200 MOhm x km Tinned copper braided screen,
Operating capacity approx. 85% coverage
(approx.-value) at 800 Hz Outer sheath of special full polyurethane
core/core at 0,14 mm = 120 pF/m compound type TMPU to
core/core 0,25 mm = 150 pF/m DIN EN 50363-10-2
core/screen at 0,14 mm = 240 pF/m Sheath colour light grey (RAL 7035)
core/screen 0,25 mm = 270 pF/m with meter marking
Inductance
approx. 0,65 mH/km
Impedance
approx. 78 Ohm
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Application
Special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications in which
food and beverages are processed unpacked and unsealed, e. g. processing of dairy products, meat, fish; production of convenience foods, brewery
and beverage industry.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
27235 1 x 0,14 2,6 6,0 16,0 26 27252 1 x 0,25 3,0 7,0 27,0 24
27236 2 x 0,14 3,9 12,0 20,0 26 27253 2 x 0,25 4,3 16,0 31,0 24
27237 3 x 0,14 4,0 13,0 27,0 26 27254 3 x 0,25 4,5 19,0 36,0 24
27238 4 x 0,14 4,3 15,0 32,0 26 27255 4 x 0,25 4,8 22,0 40,0 24
27239 5 x 0,14 4,7 16,0 37,0 26 27256 5 x 0,25 5,4 27,0 51,0 24
27240 6 x 0,14 5,2 18,0 42,0 26 27257 6 x 0,25 5,8 32,0 58,0 24
27241 7 x 0,14 5,2 19,0 48,0 26 27258 7 x 0,25 5,8 35,0 64,0 24
27242 8 x 0,14 5,9 21,0 55,0 26 27259 8 x 0,25 7,0 42,0 82,0 24
27243 10 x 0,14 6,5 29,0 65,0 26 27260 10 x 0,25 7,3 50,0 85,0 24
27244 12 x 0,14 6,7 31,0 77,0 26 27261 12 x 0,25 7,5 58,0 90,0 24
27245 14 x 0,14 6,9 32,0 79,0 26 27262 14 x 0,25 8,1 62,0 144,0 24
27246 16 x 0,14 7,3 43,0 89,0 26 27263 16 x 0,25 8,5 67,0 110,0 24
27247 18 x 0,14 7,6 51,0 103,0 26 27264 18 x 0,25 9,1 78,0 142,0 24
27248 20 x 0,14 8,3 55,0 116,0 26 27265 19 x 0,25 9,1 79,0 146,0 24
27249 21 x 0,14 8,4 56,0 120,0 26 27266 20 x 0,25 9,5 152,0 88,0 24
27250 24 x 0,14 8,9 62,0 131,0 26 27267 21 x 0,25 9,6 91,0 150,0 24
27251 25 x 0,14 9,1 61,0 136,0 26 27268 24 x 0,25 10,4 96,0 163,0 24

Continuation

120
Flexible Control Cables / Hygienic Cables

NANOFLEX HC*TRONIC-C EMC preferred type, flexible, colour code


to DIN 47100, screened, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
27269 25 x 0,25 10,6 99,0 169,0 24 27294 7 x 0,5 7,3 68,0 98,0 20
27270 1 x 0,34 3,2 13,0 24,0 22 27295 8 x 0,5 8,6 80,0 117,0 20
27271 2 x 0,34 4,9 18,0 30,0 22 27296 10 x 0,5 9,4 93,0 135,0 20
27272 3 x 0,34 5,1 22,0 37,0 22 27297 12 x 0,5 9,6 117,0 157,0 20
27273 4 x 0,34 5,5 28,0 48,0 22 27298 14 x 0,5 10,1 122,0 190,0 20
27274 5 x 0,34 6,0 31,0 54,0 22 27299 16 x 0,5 10,6 129,0 210,0 20
27275 6 x 0,34 6,6 45,0 61,0 22 27300 18 x 0,5 11,3 152,0 217,0 20
27276 7 x 0,34 6,6 51,0 67,0 22 27301 19 x 0,5 11,3 156,0 246,0 20
27277 8 x 0,34 7,7 54,0 81,0 22 27302 20 x 0,5 12,0 173,0 275,0 20
27278 10 x 0,34 8,4 65,0 103,0 22 27303 24 x 0,5 13,2 256,0 337,0 20
27279 12 x 0,34 8,6 70,0 110,0 22 27304 25 x 0,5 13,7 250,0 351,0 20
27280 14 x 0,34 9,0 81,0 153,0 22 27305 1 x 0,75 4,0 19,0 41,0 19
27281 16 x 0,34 9,6 88,0 159,0 22 27306 2 x 0,75 5,8 38,0 59,0 19
27282 18 x 0,34 10,1 103,0 172,0 22 27307 3 x 0,75 6,3 50,0 66,0 19
27283 19 x 0,34 10,1 106,0 181,0 22 27308 4 x 0,75 6,8 57,0 77,0 19
27284 20 x 0,34 10,8 112,0 191,0 22 27309 5 x 0,75 7,4 70,0 93,0 19
27285 21 x 0,34 10,9 116,0 199,0 22 27310 6 x 0,75 8,2 87,0 113,0 19
27286 24 x 0,34 11,7 129,0 229,0 22 27311 7 x 0,75 8,2 96,0 130,0 19
27287 25 x 0,34 12,0 120,0 241,0 22 27312 8 x 0,75 9,7 110,0 145,0 19
27288 1 x 0,5 3,5 15,0 40,0 20 27313 10 x 0,75 10,3 140,0 180,0 19
27289 2 x 0,5 5,3 29,0 45,0 20 27314 12 x 0,75 10,5 151,0 202,0 19
27290 3 x 0,5 5,6 39,0 55,0 20 27315 14 x 0,75 11,3 167,0 225,0 19
27291 4 x 0,5 6,3 46,0 61,0 20 27316 16 x 0,75 11,9 183,0 275,0 19
27292 5 x 0,5 6,8 52,0 76,0 20 27317 18 x 0,75 12,7 207,0 292,0 19
27293 6 x 0,5 7,3 66,0 89,0 20 27318 19 x 0,75 12,7 221,0 322,0 19
27319 20 x 0,75 13,6 238,0 362,0 19
27320 24 x 0,75 14,9 270,0 435,0 19
27321 25 x 0,75 15,0 278,0 415,0 19

Dimensions and specifications may be changed without prior notice. (RA02)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-Clean

121
DATA & COMPUTER CABLES


ge
B

3
in

ta
d

E
VD eld 29
ng

x
xe
ex

VD
le U
ol

ed

R/ shi E 0
xi
p 0/
- fi
- fl

lv

./
fle

x
to U

ed
ve

no
H A ed / VD
-f
C)

C)

g ge

s-

us

CS REG
e n es /
(

tin lta

e
di

di

se
re

re

t
fre

ut tan
ra vo

r
n
ra

ra

co
tu

tu

E
ai
n-
pe l

or
sis
ra

ra

g
O na

A
d
ch
ge
in

in
pe

pe

re
do
re
i

ge
om

nd

nd

ag
lo

lo

re
V-
m

L/
Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
Data & computer cables

TRONIC (LiYY) -5 to +80 -40 to +80 350 7.5x 4x X 124

PAAR-TRONIC -5 to +80 -30 to +80 350 7.5x 4x X 126

SENSORFLEX -5 to +80 -30 to +80 350 7.5/15x (X) X 128

VERTEILERFLEX -5 to +80 -30 to +80 300/500 7.5/15x (X) X 129

DATAFLAMM
+5 to +70 -40 to +70 350 7.5x 7.5x X X 130

TRONIC-CY (LiY-CY) -5 to +80 -40 to +80 350 10x 5x X X 131

PAAR-TRONIC-CY -5 to +80 -30 to +80 350 10x 5x X X 133

PAAR-CY-OZ -5 to +80 -40 to +80 300/500 10x 5x X 135

PAAR-TRONIC-CY-CY (LiYCY-CY) -5 to +80 -40 to +80 350 12x 6x X X 136

PAAR-TRONIC-Li-2YCYv -5 to +70 -30 to +80 250 12x 7.5x X X X 138

PAAR-TRONIC-Li-2YCY -5 to +70 -30 to +80 250 12x 7.5x X X 139

LifYCY -5 to +70 -40 to +70 350 10x 5x X X 140

TRONIC 1-CY -5 to +80 -40 to +80 250 10x 5x X X 141

TRONIC 2-CY -5 to +80 -40 to +80 350 10x 5x X X 142

LiY-TPC-Y -5 to +70 -30 to +70 500 12x 7.5x X X 143

DATAPUR -C
-5 to +80 -40 to +80 350 10x 5x X X X X 144

DATAFLAMM-C +5 to +70 -40 to +70 350 7.5x 7.5x X X X 145

DATAFLAMM -C-PAAR

+5 to +70 -40 to +70 350 7.5x 7.5x X X X 146

EDV-PiMF-CY -5 to +80 -20 to +80 300 10x 5x X X 147

RD-Y(St)Y -5 to +50 -40 to +70 600 7.5x 7.5x X X 148

RD-Y(St)Yv / RD-Y(St)YY -5 to +50 -40 to +70 600 7.5x 7.5x X X X 149

RE-2Y(St)YV -5 to +50 -40 to +70 300 7.5x 7.5x X X X 150

RE-2Y(St)YV PiMF -5 to +50 -40 to +70 300 7.5x 7.5x X X X 151

JE-Y(St)Y -5 to +50 -30 to +70 225 6x X X 152

JE-LiYCY -5 to +50 -30 to +70 225 6x X X 153

JE-LiHCH -5 to +50 -30 to +70 225 7.5x 7.5x X X X 154

RD-H(St)H -5 to +50 -30 to +70 225 7.5x 7.5x X (X) X X 155

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

123
Data and Computer Cables

TRONIC (LiYY) flexible, colour coded to DIN 47100, meter marking

Technical data Cable structure Properties


Special-PVC data cables adapted Bare copper-conductor, from 0,5 mm to Extensively oil resistant, oil-/ chemical
to DIN VDE 0812 DIN VDE 0295 cl.5, fine-wire, Resistance - see table Technical
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Informations
flexing -5C to +80C Conductor construction: The materials used in manufacture are
fixed installation -40C to +80C 0,14 mm = 18x0,1 mm cadmium-free and contain no silicone
Operating peak voltage 0,25 mm = 14x0,15 mm and free from substances harmful to
(not for purposes of high current and 0,34 mm = 7x0,25 mm the wetting properties of lacquers
power installation) Core insulation of special PVC Tests
0,14 mm = 350 V compound type TI2 to PVC self-extinguishing and flame retardant
0,25 mm = 500 V DIN VDE 0207-363-3 / DIN EN 50363-3 acc. to DIN VDE 0482-332-1-2,
Test voltage Core identification to DIN 47100, DIN EN 60332-1-2, IEC 60332-1 (equivalent
up to 0,25 mm 1200 V without colour repetition DIN VDE 0472 part 804 test method B)
from 0,34 mm 2000 V Cores stranded in layers with
Breakdown voltage optimal lay-length Note
up to 0,25 mm 2400 V Outer sheath of special PVC Also available in paired version, see
from 0,34 mm 4000 V compound type TM2 to HELUKABEL-PAAR-TRONIC
Insulation resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1 AWG sizes are approximate equivalent
min. 20 MOhm x km Sheath colour grey (RAL 7001) values. The actual cross-section is in mm.
Capacitance (approx.-value) at 800 Hz with meter marking screened analogue type:
0,14 mm 120 pF/m TRONIC-CY (LiY-CY), confer page 131
0,25 mm 150 pF/m
Inductance approx. 0,65 mH/km
Impedance approx. 78 Ohm
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
These cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable
for open air, wherever the construction requirements call for a minimum outer diameter, TRONIC is the suitable cable to use. This applies especially
to such areas as tool making and machine industries as well as electronic, computer, measurement and control sectors.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
18001 2 x 0,14 3,5 2,7 13,0 26 18029 2 x 0,25 3,8 4,8 18,0 24
18002 3 x 0,14 3,7 4,0 16,0 26 18030 3 x 0,25 4,0 7,2 22,0 24
18003 4 x 0,14 3,9 5,4 19,0 26 18031 4 x 0,25 4,3 9,6 26,0 24
18004 5 x 0,14 4,3 6,7 22,0 26 18032 5 x 0,25 4,7 12,0 30,0 24
18005 6 x 0,14 4,6 8,1 25,0 26 18033 6 x 0,25 5,3 14,4 36,0 24
18006 7 x 0,14 4,6 9,4 28,0 26 18034 7 x 0,25 5,3 16,8 42,0 24
18007 8 x 0,14 5,5 10,7 35,0 26 18035 8 x 0,25 6,1 19,2 49,0 24
18008 10 x 0,14 5,9 13,4 41,0 26 18036 10 x 0,25 6,8 24,0 57,0 24
18009 12 x 0,14 6,1 16,1 48,0 26 18037 12 x 0,25 7,0 28,8 66,0 24
18010 14 x 0,14 6,3 18,8 53,0 26 18038 14 x 0,25 7,3 33,6 75,0 24
18011 16 x 0,14 6,9 21,5 59,0 26 18039 16 x 0,25 7,7 38,4 84,0 24
18012 18 x 0,14 7,2 24,2 65,0 26 18040 18 x 0,25 8,3 43,2 72,0 24
18013 20 x 0,14 7,5 26,9 70,0 26 18114 19 x 0,25 8,3 46,0 84,0 24
18014 21 x 0,14 7,6 28,2 77,0 26 18041 20 x 0,25 8,7 48,0 101,0 24
18015 24 x 0,14 8,5 32,3 87,0 26 18042 21 x 0,25 8,8 50,0 107,0 24
18117 25 x 0,14 8,6 33,6 91,0 26 18043 24 x 0,25 9,8 60,0 120,0 24
18016 27 x 0,14 8,7 36,3 97,0 26 18118 25 x 0,25 10,0 61,0 132,0 24
18017 30 x 0,14 8,9 40,3 108,0 26 18044 27 x 0,25 10,1 65,0 140,0 24
18018 32 x 0,14 9,3 43,0 114,0 26 18045 30 x 0,25 10,3 72,0 156,0 24
18019 36 x 0,14 9,8 48,4 126,0 26 18046 32 x 0,25 10,7 77,0 164,0 24
18020 40 x 0,14 10,4 54,0 139,0 26 18047 36 x 0,25 11,3 86,0 182,0 24
18021 42 x 0,14 10,5 56,0 146,0 26 18115 37 x 0,25 11,3 89,0 190,0 24
18022 44 x 0,14 11,1 59,0 153,0 26 18048 40 x 0,25 12,1 96,0 200,0 24
18023 48 x 0,14 11,2 65,0 164,0 26 18049 42 x 0,25 12,2 101,0 211,0 24
18024 52 x 0,14 11,5 70,0 173,0 26 18050 44 x 0,25 12,8 106,0 225,0 24
18025 56 x 0,14 11,8 75,0 187,0 26 18051 48 x 0,25 13,0 115,0 245,0 24
18026 61 x 0,14 12,1 82,0 204,0 26 18052 52 x 0,25 13,3 125,0 263,0 24
18027 80 x 0,14 14,1 108,0 280,0 26 18053 56 x 0,25 13,9 134,0 280,0 24
18028 100 x 0,14 15,6 135,0 370,0 26 18054 61 x 0,25 14,3 146,0 305,0 24

Continuation

124
Data and Computer Cables

TRONIC (LiYY) flexible, colour coded to DIN 47100, meter marking

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
18055 80 x 0,25 16,5 192,0 450,0 24 18085 2 x 0,5 4,6 9,6 40,0 20

B
18056 100 x 0,25 18,3 240,0 590,0 24 18086 3 x 0,5 4,9 14,4 46,0 20
18057 2 x 0,34 4,2 6,5 22,0 22 18087 4 x 0,5 5,5 19,2 55,0 20
18058 3 x 0,34 4,4 9,8 30,0 22 18088 5 x 0,5 6,0 24,0 64,0 20
18059 4 x 0,34 4,8 13,1 43,0 22 18089 6 x 0,5 6,7 28,8 73,0 20
18060 5 x 0,34 5,4 16,3 54,0 22 18090 7 x 0,5 6,7 33,6 81,0 20
18061 6 x 0,34 5,9 19,6 58,0 22 18091 8 x 0,5 7,8 38,4 97,0 20
18062 7 x 0,34 5,9 22,8 61,0 22 18092 10 x 0,5 8,6 48,0 116,0 20
18063 8 x 0,34 7,1 26,1 73,0 22 18093 12 x 0,5 8,7 58,0 135,0 20
18064 10 x 0,34 7,6 32,6 82,0 22 18103 16 x 0,5 10,0 77,0 168,0 20
18065 12 x 0,34 7,8 39,2 102,0 22 18101 20 x 0,5 11,3 96,0 213,0 20
18066 14 x 0,34 8,4 45,7 108,0 22 18094 24 x 0,5 12,7 116,0 241,0 20
18067 16 x 0,34 8,8 52,0 126,0 22 18102 30 x 0,5 13,4 144,0 303,0 20
18068 18 x 0,34 9,3 59,0 143,0 22 18095 40 x 0,5 15,8 192,0 391,0 20
18069 20 x 0,34 10,0 65,0 160,0 22 18104 2 x 0,75 5,3 14,4 47,0 19
18070 21 x 0,34 10,1 69,0 166,0 22 18097 3 x 0,75 5,6 21,6 54,0 19
18071 24 x 0,34 11,2 78,0 186,0 22 18098 4 x 0,75 6,1 29,0 66,0 19
18096 25 x 0,34 11,4 82,0 192,0 22 18099 5 x 0,75 6,9 36,0 80,0 19
18072 27 x 0,34 11,5 88,0 206,0 22 18100 7 x 0,75 7,5 50,0 110,0 19
18073 30 x 0,34 11,8 98,0 226,0 22 18105 8 x 0,75 8,9 58,0 125,0 19
18074 32 x 0,34 12,3 104,0 245,0 22 18106 10 x 0,75 9,2 72,0 148,0 19
18075 36 x 0,34 12,9 118,0 285,0 22 18107 12 x 0,75 9,8 86,0 176,0 19
18116 37 x 0,34 12,9 121,0 292,0 22 18108 16 x 0,75 11,4 115,0 220,0 19
18076 40 x 0,34 14,0 131,0 318,0 22 18109 20 x 0,75 12,7 144,0 276,0 19
18077 42 x 0,34 14,1 137,0 330,0 22 18110 2x1 5,6 19,2 56,0 18
18078 44 x 0,34 14,6 144,0 370,0 22 18111 3x1 5,9 29,0 71,0 18
18079 48 x 0,34 14,7 157,0 405,0 22 18112 2 x 1,5 6,3 29,0 75,0 16
18080 52 x 0,34 15,4 170,0 430,0 22 18113 3 x 1,5 6,8 43,0 90,0 16
18081 53 x 0,34 15,8 183,0 440,0 22
18082 61 x 0,34 16,3 199,0 610,0 22
18083 80 x 0,34 18,8 264,0 880,0 22
18084 100 x 0,34 21,0 327,0 1050,0 22

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Cable tie

125
Data and Computer Cables

PAAR-TRONIC flexible, colour coded to DIN 47100, meter marking

Technical data Cable structure Properties


Special-PVC data cable for Bare copper-conductor, from 0,5 mm to Extensively oil resistant, oil-/ chemical
electronic control adapted DIN VDE 0295 cl.5, fine-wire, Resistance - see table Technical
to DIN VDE 0812 and 0814 BS 6360 cl.5, IEC 60228 cl.5 Informations
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -5C to +80C compound type TI2 to cadmium-free and contain no silicone
fixed installation -30C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 and free from substances harmful to
Operating peak voltage 350 V Core identification (pair) to DIN 47100 the wetting properties of lacquers
(not for heavy current installation purposes) Cores stranded in pairs with optimal Tests
Test voltage 1200 V lay-length PVC self-extinguishing and flame retardant
Breakdown voltage min. 2400 V Pairs stranded in layers with optimal acc. to DIN VDE 0482-332-1-2,
Insulation resistance lay-length DIN EN 60332-1-2, IEC 60332-1 (equivalent
min. 20 MOhm x km Foil wrapping DIN VDE 0472 part 804 test method B)
Capacitance (approx.-value) at 800 Hz Outer sheath of special PVC
core/core 0,14 mm = 120 pF/m compound type TM2 to Note
core/core 0,25 mm = 150 pF/m DIN VDE 0207-363-4-1/DIN EN 50363-4-1 AWG sizes are approximate equivalent
Inductance approx. 0,65 mH/km Sheath colour grey (RAL 7032) values. The actual cross-section is in mm.
Impedance approx. 78 Ohm with meter marking screened analogue type:
K1-coupling approx. 300 pF/100 m PAAR-TRONIC-CY, confer page 133
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but
not suitable for open air. PAAR-TRONIC is the perfect cable for use in areas where a small diameter is essential to complete wiring. E. g. as a control
and signal cable in measuring instruments, computers, signal transfer etc. This cable is suitable only for low load application.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
19001 1 x 2 x 0,14 3,6 2,7 20,0 26 19018 24 x 2 x 0,14 12,2 65,0 170,0 26
19002 2 x 2 x 0,14 4,6 5,4 25,0 26 19019 25 x 2 x 0,14 12,3 67,0 180,0 26
19003 3 x 2 x 0,14 5,1 8,0 31,0 26 19020 26 x 2 x 0,14 12,4 70,0 184,0 26
19004 4 x 2 x 0,14 5,5 10,7 38,0 26 19021 27 x 2 x 0,14 12,5 73,0 188,0 26
19005 5 x 2 x 0,14 6,3 13,4 45,0 26 19022 28 x 2 x 0,14 13,5 75,0 192,0 26
19006 6 x 2 x 0,14 6,7 16,1 50,0 26 19023 30 x 2 x 0,14 13,6 81,0 200,0 26
19007 7 x 2 x 0,14 6,7 18,8 57,0 26 19024 32 x 2 x 0,14 14,0 86,0 224,0 26
19008 8 x 2 x 0,14 7,6 21,5 64,0 26 19025 34 x 2 x 0,14 14,1 91,0 247,0 26
19009 10 x 2 x 0,14 8,5 26,9 78,0 26 19026 36 x 2 x 0,14 14,9 97,0 260,0 26
19010 11 x 2 x 0,14 9,0 29,5 86,0 26 19027 38 x 2 x 0,14 15,6 102,0 272,0 26
19011 12 x 2 x 0,14 9,1 32,3 94,0 26 19028 40 x 2 x 0,14 15,9 108,0 294,0 26
19012 14 x 2 x 0,14 9,8 37,6 105,0 26 19029 44 x 2 x 0,14 16,2 118,0 334,0 26
19013 15 x 2 x 0,14 10,1 40,3 108,0 26 19030 45 x 2 x 0,14 16,4 121,0 342,0 26
19014 16 x 2 x 0,14 10,2 43,0 110,0 26 19031 50 x 2 x 0,14 17,4 134,0 387,0 26
19015 18 x 2 x 0,14 10,6 48,4 119,0 26 19032 52 x 2 x 0,14 17,4 140,0 403,0 26
19016 20 x 2 x 0,14 10,8 54,0 130,0 26 19033 55 x 2 x 0,14 18,0 148,0 427,0 26
19017 22 x 2 x 0,14 11,7 59,0 150,0 26

Continuation

126
Data and Computer Cables

PAAR-TRONIC flexible, colour coded to DIN 47100, meter marking

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
19034 1 x 2 x 0,25 4,0 5,0 32,0 24 19057 32 x 2 x 0,25 17,1 160,0 410,0 24

B
19035 2 x 2 x 0,25 5,4 10,0 37,0 24 19058 34 x 2 x 0,25 17,5 170,0 425,0 24
19036 3 x 2 x 0,25 5,9 15,0 47,0 24 19059 36 x 2 x 0,25 17,8 180,0 440,0 24
19037 4 x 2 x 0,25 6,8 20,0 58,0 24 19060 38 x 2 x 0,25 18,3 190,0 480,0 24
19038 5 x 2 x 0,25 7,7 25,0 70,0 24 19061 40 x 2 x 0,25 19,0 200,0 530,0 24
19039 6 x 2 x 0,25 8,4 30,0 80,0 24 19062 44 x 2 x 0,25 19,7 220,0 580,0 24
19040 7 x 2 x 0,25 8,4 35,0 89,0 24 19063 45 x 2 x 0,25 20,0 225,0 600,0 24
19041 8 x 2 x 0,25 8,7 40,0 99,0 24 19064 50 x 2 x 0,25 21,0 250,0 650,0 24
19042 10 x 2 x 0,25 10,3 50,0 114,0 24 19065 52 x 2 x 0,25 21,0 260,0 670,0 24
19043 11 x 2 x 0,25 10,4 55,0 126,0 24 19066 55 x 2 x 0,25 21,5 275,0 790,0 24
19044 12 x 2 x 0,25 10,5 60,0 137,0 24 19067 1 x 2 x 0,34 4,6 6,5 36,0 22
19045 14 x 2 x 0,25 11,4 70,0 161,0 24 19068 2 x 2 x 0,34 6,3 13,1 42,0 22
19046 15 x 2 x 0,25 11,7 75,0 174,0 24 19069 3 x 2 x 0,34 6,7 19,6 50,0 22
19047 16 x 2 x 0,25 12,0 80,0 187,0 24 19070 4 x 2 x 0,34 7,6 26,1 61,0 22
19048 18 x 2 x 0,25 12,6 90,0 212,0 24 19071 1 x 2 x 0,5 4,9 9,6 42,0 20
19049 20 x 2 x 0,25 13,4 100,0 234,0 24 19072 2 x 2 x 0,5 7,2 19,2 51,0 20
19050 22 x 2 x 0,25 14,2 110,0 250,0 24 19073 3 x 2 x 0,5 7,8 28,8 62,0 20
19051 24 x 2 x 0,25 14,9 120,0 280,0 24 19074 4 x 2 x 0,5 8,6 38,4 73,0 20
19052 25 x 2 x 0,25 15,0 125,0 300,0 24 19075 1 x 2 x 0,75 5,8 14,4 47,0 19
19053 26 x 2 x 0,25 15,1 130,0 320,0 24 19076 2 x 2 x 0,75 8,7 28,8 59,0 19
19054 27 x 2 x 0,25 15,2 135,0 330,0 24 19077 3 x 2 x 0,75 8,9 43,2 74,0 19
19055 28 x 2 x 0,25 16,0 140,0 345,0 24 19078 4 x 2 x 0,75 10,2 57,6 93,0 19
19056 30 x 2 x 0,25 16,2 150,0 370,0 24

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Cable tie

127
Sensor-Actuator-Cables

SENSORFLEX sensor actuator cable, PVC, PUR, PVC/PUR

Technical data Cable structure Properties


Temperature range SENSORFLEXPVC SENSORFLEXPVC
flexing -5C to +80C Bare copper-conductor, to Extensively oil resistant;
fixed installation -30C to +80C DIN VDE 0295 cl.5 or cl.6, fine-wire Chemical Resistance (see table
Peak operating voltage or extra-fine-wire, BS 6360 cl.5 or cl.6, Technical Informations)
up to 0,25 mm 350 V IEC 60228 cl.5 or cl.6 PVC self-extinguishing and flame retardant
from 0,34 mm 500 V Core insulation of PVC acc. to DIN VDE 0482-332-1-2,
A.c. test voltage, 50 Hz Core identification see table below DIN EN 60332-1-2, IEC 60332-1 (equivalent
up to 0,25 mm 1200 V Outer sheath of special PVC DIN VDE 0472 part 804 test method B)
from 0,34 mm 2000 V SENSORFLEXPUR SENSORFLEXPUR
Minimum bending radius Bare copper-conductor, to low adhesion, extremely abrasion resistant,
SENSORFLEX PUR 7,5x cable DIN VDE 0295 cl.6, extra fine-wire, resistant to hydrolysis and microbial attack
SENSORFLEX PVC/PUR 7,5x cable BS 6360 cl.6, IEC 60228 cl.6 Special feature
SENSORFLEX PVC 15x cable Core insulation of PVC The cables with the highly flexible
Core identification see table below stranded conductor, cl. 6, are
Outer sheath of PUR suitable for drag chain applications
SENSORFLEXPVC/PUR These cables are produced to high
Construction as per SENSORFLEX PVC quality specifications and conform
PVC inner sheath, with PUR sheath applied with a yellow sheath to the
over it by means of coextrusion DESINA-standard
Sheath colour yellow (RAL 1021) acc. to
DESINA

Note
All cables can be delivered with UL/CSA
approval and Cu shield.
DESINA: Explanation: see introduction.

Application
For decentralised installation and control technology. These cables are used in connector systems for sensors and actuators. In combination with
injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element between the periphery and the PLC
in production systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also
in the entire manufacturing industry. While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now
field bus technology has made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. Moving the
I/O points to the system periphery enables significant reductions in installation costs.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cable structure AWG-No.


yellow orange grey No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** approx. weight approx.
mm mm kg / km kg / km
76061 76076 73473 3 x 0,25 PVC BN, BU, BK X 4,4 7,2 22,0 24
76062 76077 73466 3 x 0,25 PUR BN, BU, BK X 4,4 7,2 22,0 24
76063 76078 73474 4 x 0,25 PVC BN, BU, BK, WH X 4,7 9,6 26,0 24
76064 76079 73471 4 x 0,25 PUR BN, BU, BK, WH X 4,7 9,6 26,0 24
76065 76080 76094 5 G 0,25 PVC BN, BU, BK, WH, GN-YE X 4,8 12,0 30,0 24
76066 76081 76095 5 G 0,25 PVC/PUR BN, BU, BK, WH, GN-YE X 4,8 12,0 30,0 24
76071 76086 73472 3 G 0,34 PVC/PUR BN, BU, GN-YE X 4,9 9,8 30,0 22
76070 76085 76099 3 x 0,34 PVC BN, BU, BK X 4,9 9,8 30,0 22
73485 76087 73368 4 x 0,34 PVC BN, BU, BK, WH X 5,2 13,1 43,0 22
73484 76088 72973 4 x 0,34 PVC/PUR BN, BU, BK, WH X 5,2 13,1 43,0 22
78240 78241 73728 5 x 0,34 PVC BN, BU, BK, WH, GY X 5,9 16,4 54,0 22
76072 76089 73657 5 G 0,34 PVC BN, BU, BK, WH, GN-YE X 5,9 16,4 54,0 22
73870 76090 73548 5 G 0,34 PVC/PUR BN, BU, BK, WH, GN-YE X 5,9 16,4 54,0 22

Dimensions and specifications may be changed without prior notice.

128
Sensor-Actuator-Cables

VERTEILERFLEX for sensor actuator distributor boxes, PVC, PUR or PVC/PUR

Technical data Cable structure Properties


Temperature range PVC cables PVC cables
flexing -5C to +80C Bare copper-conductor, acc. to Extensively oil resistant.
fixed installation -30C to +80C DIN VDE 0295 cl.5, fine-wire, Chemical Resistance - see table Technical
Operating voltage BS 6360 cl.5, IEC 60228 cl.5 Informations
U0/U 300/500 V Core insulation of PVC PVC self-extinguishing and flame retardant
A.c. test voltage, 50 Hz Core identification see table below acc. to DIN VDE 0482-332-1-2,
2000 V Outer sheath of special PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius PUR cables DIN VDE 0472 part 804 test method B)
flexibel 15x cable Bare copper-conductor, to PUR cables
highly flexible 7,5x cable DIN VDE 0295 cl.6, extra fine-wire, Low adhesion, extremely abrasion resistant,
BS 6360 cl.6, IEC 60228 cl.6 resistant to hydrolysis and microbial attack
Core insulation of PVC Special feature
Core identification see table below The cables with the highly flexible stranded
Outer sheath of PUR conductor, cl. 6, are
suitable for drag chain applications
Note The types with PVC/PUR sheath material
All cables can be delivered with UL/CSA have a PVC inner sheath, with a PUR sheath
approbation and Cu shield. applied over it by means of coextrusion
Further core numbers, cross-sections an
sheath colours available on request.

Application
These cables are used in connector systems for sensors an actuators. In combination with injected circular connectors and installed actuator-sensor
boxes, they constitute an important connecting element between the periphery and the PLC in production systems. The assembled cables offer attractive
opportunities for reducing costs, not only in the field of automation technology, but also in the entire manufacturing industry.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cable structure AWG-No.


black grey No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** approx. weight approx.
mm mm kg / km kg / km
76105 76115 4 G 0,34 PVC BN, BU, BK, WH, GN-YE X 5,8 18,0 58,0 22
76639 4 G 0,34 PVC/PUR YE, WH, GN, GY, GN-YE, BN, BU X 8,7 36,0 82,0 22
76107 73574 6 G 0,34 PVC/PUR WH, GN, YE, GY, PK, RD, BN, BU, GN-YE X 9,1 42,0 106,0 22
72961 73993 8 G 0,34 PVC/PUR GY, PK, RD, BK, VT, WH, GN, YE, BN, BU, GN-GE X 9,1 48,0 110,0 22
76109 74729 8 x 0,34 PVC WH, GN, YE, GY, PK, RD, BK, VT, BU, BN X 9,1 41,0 107,0 22
76110 72951 8 x 0,34 PUR WH, GN, YE, GY, PK, RD, BK, VT, BU, BN X 9,1 41,0 107,0 22
76108 76117 8 x 0,34 PVC/PUR WH, GN, YE, GY, PK, RD, BK, VT, BU, BN X 8,8 36,0 102,0 22
71254 76118 11 x 0,34 PVC BK with number 1-2, DIN 47100 X 10,0 65,0 143,0 22
76111 76119 12 x 0,34 PVC/PUR PK, YE/BN, RD, GY/PK, WH, RD/BU, GN, WH/GN, X 10,3 61,0 138,0 22
YE, BN/GN, GY, WH/YE
77642 16 G 0,34 PVC/PUR BU with number 1-2, GN-YE, GY/PK, WH, RD/BU, X 12,5 89,0 193,0 22
GN, WH/GY, YE, BN/GY, WH/YE, PK, YE/BN, RD,
WH/GY, BK, GY/BN, VT
76112 76120 16 G 0,34 PVC/PUR BN, GY/PK, RD/BU, WH/GN, BN/GN, WH/YE, X 10,5 74,0 170,0 22
YE/BN, WH/GY, GY/BN, BU, WH, GN, YE, GY, PK,
RD, BK, VT, GN-GE
76113 76121 8 G 0,5 PUR BN, BU, GN-GE, GY/PK, RD/BU, WH/GN, BN/GN, X 9,9 68,0 136,0 20
WH, GN, YE, GY
76114 76122 12 G 0,5 PUR GY/PK, RD/BU, WH/GN, BN/GN, WH/YE, YE/BN, X 10,4 87,0 160,0 20
WH, GN, YE, GY, PK, RD, BN, BU, GN-YE
79921 14 x 0,5 PVC BK with number 1-14, BN with number 1-2, BU with X 12,3 125,0 201,0 20
number 1-2
76640 16 G 0,5 PVC/PUR GY, BN/GN, GN, RD/BU, GY/PK, WH, WH/GN, X 11,6 106,0 183,0 20
WH/GY, BK, WH/YE, PK, YE, RD, YE/BN, VT,
GY/BN, GN-GE, BN, BU
74034 76123 16 G 0,5 PUR GY/PK, WH, RD/BU, GN, WH/GN, YE, BN/GN, GY, X 11,6 106,0 183,0 20
WH/YE, PK, YE/BN, RD, WH/GN, BK, VT, BN, BU,
GN-YE

Dimensions and specifications may be changed without prior notice.

129
Data and Computer Cables

DATAFLAMM halogen-free, meter marking

Technical data Cable structure Properties


Special data cable, halogen-free Bare copper-conductor, fine-wire Tests
Temperature range to DIN VDE 0812 Halogen-free to DIN VDE 0482
flexing +5C to +70C Conductor construction: part 267, DIN EN 50267-2-1, IEC 60754-1
fixed installation -40C to +70C 0,34 mm = 7x0,25 mm (equivalent DIN VDE 0472 part 815)
Operating peak voltage Core insulation of PE Corrosiveness of combustion gases
(not for heavy current installation purposes) compound type L/MD to acc.to DIN VDE 0482 part 267,
0,14 mm = 350 V DIN VDE 0819-103 / DIN EN 50290-2-23 DIN EN 50267-2-2, IEC 60754-2
0,25 mm = 500 V Core identification to DIN 47100, (equivalent DIN VDE 0472 part 813)
Test voltage without colour repetition Halogen-free sheath compound,
0,14 mm = 800 V Cores twisted in layers with optimal self-extinguishing and flame retardant
0,25 mm = 1200 V lay-length acc.to DIN VDE 0482-332-1-2,
Insulation resistance Outer sheath DIN EN 60332-1-2, IEC 60332-1 (equivalent
min. 2 GOhm x km compound type HM2 to DIN VDE 0472 part 804 test method B)
Capacitance DIN VDE 0207 part 24
core/core < 70 nF/km Sheath colour grey (RAL 7005) Note
Minimum bending radius with meter marking AWG sizes are approximate equivalent
7,5x cable values. The actual cross-section is in mm.
Radiation resistance screened analogue type:
up to 100x106 cJ/kg (up to 100 Mrad) DATAFLAMM-C , confer page 145

Application
DATAFLAMM halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking
systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in
dry, damp and wet environments. PE-insulated-cores, compared with the conventional PVC-insulated cores, assure a remarkable and more favourable
capacitance values. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories,
trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath
produce neither corrosive nor toxic gases.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52300 2 x 0,14 3,3 2,6 14,0 26 52330 4 x 0,34 5,0 13,0 35,0 22
52301 3 x 0,14 3,5 4,0 17,0 26 52331 5 x 0,34 5,5 16,4 43,0 22
52302 4 x 0,14 3,7 5,3 19,0 26 52332 7 x 0,34 6,0 22,7 58,0 22
52303 5 x 0,14 4,0 6,6 23,0 26 52333 10 x 0,34 7,8 32,4 80,0 22
52304 6 x 0,14 4,3 7,9 25,0 26 52334 12 x 0,34 8,0 39,1 91,0 22
52305 7 x 0,14 4,3 9,2 27,0 26 52335 15 x 0,34 9,0 49,1 115,0 22
52306 8 x 0,14 4,6 10,3 30,0 26 52336 18 x 0,34 9,8 59,1 135,0 22
52307 10 x 0,14 5,4 13,2 38,0 26 52337 21 x 0,34 10,4 68,3 154,0 22
52308 12 x 0,14 5,7 16,0 45,0 26 52338 25 x 0,34 12,0 81,4 180,0 22
52309 15 x 0,14 6,1 20,1 57,0 26 52339 34 x 0,34 13,6 111,1 233,0 22
52310 18 x 0,14 6,7 23,7 65,0 26 52340 40 x 0,34 14,8 130,5 272,0 22
52311 21 x 0,14 7,0 27,9 76,0 26 52341 2 x 0,5 4,6 9,5 30,0 20
52312 25 x 0,14 7,8 33,4 88,0 26 52342 3 x 0,5 4,9 14,2 36,0 20
52313 30 x 0,14 8,2 39,3 98,0 26 52343 4 x 0,5 5,3 19,2 43,0 20
52314 34 x 0,14 8,8 45,5 111,0 26 52344 5 x 0,5 5,9 24,0 56,0 20
52315 40 x 0,14 9,5 53,6 139,0 26 52345 7 x 0,5 6,4 33,7 70,0 20
52316 50 x 0,14 10,5 64,9 764,0 26 52346 10 x 0,5 8,3 48,0 101,0 20
52317 2 x 0,25 3,8 4,7 18,0 24 52347 12 x 0,5 8,6 57,4 117,0 20
52318 3 x 0,25 4,0 7,1 21,0 24 52348 15 x 0,5 9,8 72,0 145,0 20
52319 4 x 0,25 4,3 9,5 26,0 24 52349 18 x 0,5 10,5 86,4 171,0 20
52320 5 x 0,25 4,7 12,0 31,0 24 52350 21 x 0,5 11,1 101,0 197,0 20
52321 7 x 0,25 5,1 16,6 40,0 24 52351 25 x 0,5 12,6 120,0 230,0 20
52322 10 x 0,25 6,4 24,0 56,0 24 52352 30 x 0,5 13,3 142,6 269,0 20
52323 12 x 0,25 6,6 28,6 64,0 24 52353 34 x 0,5 14,5 163,1 301,0 20
52324 15 x 0,25 7,4 36,0 80,0 24 52354 40 x 0,5 15,8 192,0 365,0 20
52430 18 x 0,25 7,9 43,2 90,0 24 52355 2 x 0,75 5,2 14,3 40,0 19
52431 21 x 0,25 8,6 50,4 105,0 24 52356 3 x 0,75 5,5 21,5 51,0 19
52325 25 x 0,25 9,4 59,8 121,0 24 52357 4 x 0,75 6,0 28,6 61,0 19
52326 34 x 0,25 11,0 81,3 168,0 24 52358 5 x 0,75 6,7 36,1 76,0 19
52327 40 x 0,25 12,0 96,0 196,0 24 52359 7 x 0,75 7,3 50,3 97,0 19
52328 2 x 0,34 4,4 6,4 25,0 22 52360 10 x 0,75 9,8 72,0 137,0 19
52329 3 x 0,34 4,7 9,7 30,0 22 52361 12 x 0,75 10,0 86,2 167,0 19

Dimensions and specifications may be changed without prior notice. (RB01)

130
Data and Computer Cables

TRONIC-CY (LiY-CY) flexible, Cu-screened, colour coded to DIN 47100,


EMC-preferred type, meter marking

Technical data Cable structure Properties


Special-PVC data cable for Bare copper-conductor, from 0,5 mm to Extensively oil resistant, oil-/ chemical
electronic control adapted DIN VDE 0295 cl.5, fine-wire, Resistance - see table Technical
to DIN VDE 0812 BS 6360 cl.5, IEC 60228 cl.5 Informations
Temperature range Conductor construction: The materials used in manufacture are
flexing -5C to +80C 0,14 mm = 18x0,1 mm cadmium-free and contain no silicone
fixed installation -40C to +80C 0,25 mm = 14x0,15 mm and free from substances harmful to
Operating peak voltage 0,34 mm = 7x0,25 mm the wetting properties of lacquers
(not for heavy current installation purposes) Core insulation of special PVC Tests
0,14 mm = 350 V compound type TI2 to PVC self-extinguishing and flame retardant
0,25 mm = 500 V DIN VDE 0207-363-3 / DIN EN 50363-3 acc. to DIN VDE 0482-332-1-2,
Test voltage Core identification to DIN 47100, DIN EN 60332-1-2, IEC 60332-1 (equivalent
core/core 1200 V without colour repetition DIN VDE 0472 part 804 test method B)
core/screen 800 V Cores stranded in layers with
Breakdown voltage min. 2400 V optimal lay-length Note
Insulation resistance Foil wrapping Also available in paired version, see
min. 20 MOhm x km Drain-wire, tinned HELUKABEL-PAAR-TRONIC-CY
Capacitance (approx.-value) at 800 Hz Tinned, copper braided screen, For 1 core cable screen of helically wound.
core/core at 0,14 mm = 120 pF/m approx. 85% coverage AWG sizes are approximate equivalent
core/core 0,25 mm = 150 pF/m Outer sheath of special PVC values. The actual cross-section is in mm.
core/screen at 0,14 mm = 240 pF/m compound type TM2 to unscreened analogue type:
core/screen 0,25 mm = 270 pF/m DIN VDE 0207-363-4-1/DIN EN 50363-4-1 TRONIC (LiYY), confer page 124
Inductance approx. 0,65 mH/km Sheath colour grey (RAL 7001)
Impedance approx. 78 Ohm with meter marking
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
These screened cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not
suitable for open air, wherever the construction requirements call for a minimum outer diameter, TRONIC is the suitable cable to use. This applies
especially to such areas as tool making and machine industries as well as electronic, computer, measurement and control sectors. The extremely small
outer diameter make suitable for miniature plugs etc.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
20139 1 x 0,14 2,6 6,1 16,0 26 20015 24 x 0,14 8,9 62,0 131,0 26
20001 2 x 0,14 3,9 12,0 20,0 26 20091 25 x 0,14 9,1 61,0 136,0 26
20002 3 x 0,14 4,0 13,0 27,0 26 20016 27 x 0,14 9,2 65,0 142,0 26
20003 4 x 0,14 4,3 14,5 32,0 26 20017 30 x 0,14 9,5 69,0 157,0 26
20004 5 x 0,14 4,7 15,5 37,0 26 20018 32 x 0,14 9,9 76,0 163,0 26
20005 6 x 0,14 5,2 18,2 42,0 26 20019 36 x 0,14 10,2 83,0 182,0 26
20006 7 x 0,14 5,2 19,0 48,0 26 20020 40 x 0,14 11,1 88,0 209,0 26
20007 8 x 0,14 5,9 21,3 55,0 26 20021 42 x 0,14 11,2 94,0 217,0 26
20008 10 x 0,14 6,5 28,7 65,0 26 20022 44 x 0,14 11,5 110,0 226,0 26
20009 12 x 0,14 6,7 30,5 77,0 26 20023 48 x 0,14 11,7 115,0 240,0 26
20010 14 x 0,14 6,9 32,0 79,0 26 20024 52 x 0,14 12,3 124,0 270,0 26
20011 16 x 0,14 7,3 43,2 89,0 26 20025 56 x 0,14 12,5 132,0 320,0 26
20012 18 x 0,14 7,6 51,0 103,0 26 20026 61 x 0,14 12,8 146,0 370,0 26
20013 20 x 0,14 8,3 55,0 116,0 26 20027 80 x 0,14 14,7 226,0 510,0 26
20014 21 x 0,14 8,4 56,0 120,0 26 20028 100 x 0,14 16,3 267,0 580,0 26

Continuation

131
Data and Computer Cables

TRONIC-CY (LiY-CY) flexible, Cu-screened, colour coded to DIN 47100,


EMC-preferred type, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
20084 1 x 0,25 3,0 7,2 27,0 24 16012 16 x 0,5 10,6 129,0 210,0 20
20029 2 x 0,25 4,3 15,8 31,0 24 16013 18 x 0,5 11,3 152,0 217,0 20
20030 3 x 0,25 4,5 18,6 36,0 24 16526 19 x 0,5 11,3 156,0 246,0 20
20031 4 x 0,25 4,8 22,0 40,0 24 16014 20 x 0,5 12,0 173,0 275,0 20
20032 5 x 0,25 5,4 26,5 51,0 24 16015 24 x 0,5 13,2 236,0 337,0 20
20083 6 x 0,25 5,8 32,4 58,0 24 16016 25 x 0,5 13,7 250,0 351,0 20
20033 7 x 0,25 5,8 35,0 64,0 24 16527 27 x 0,5 13,8 265,0 373,0 20
20034 8 x 0,25 7,0 42,1 82,0 24 16017 30 x 0,5 14,2 297,0 396,0 20
20035 10 x 0,25 7,3 49,9 85,0 24 16018 32 x 0,5 14,7 301,0 431,0 20
20036 12 x 0,25 7,5 58,0 90,0 24 16164 34 x 0,5 15,4 312,0 440,0 20
20037 14 x 0,25 8,1 62,0 144,0 24 16019 36 x 0,5 15,5 320,0 445,0 20
20038 16 x 0,25 8,5 67,0 110,0 24 16528 37 x 0,5 15,5 325,0 458,0 20
20039 18 x 0,25 9,1 78,0 142,0 24 16020 40 x 0,5 16,4 345,0 470,0 20
20086 19 x 0,25 9,1 79,0 146,0 24 16021 50 x 0,5 18,2 407,0 570,0 20
20040 20 x 0,25 9,5 88,0 152,0 24 16022 61 x 0,5 19,2 508,0 650,0 20
20041 21 x 0,25 9,6 91,0 150,0 24 16023 80 x 0,5 22,1 690,0 780,0 20
20042 24 x 0,25 10,4 96,0 163,0 24 16024 100 x 0,5 24,6 814,0 990,0 20
20092 25 x 0,25 10,6 99,0 169,0 24 16025 1 x 0,75 4,0 19,0 41,0 19
20043 27 x 0,25 10,7 122,0 176,0 24 16026 2 x 0,75 5,8 38,0 59,0 19
20044 30 x 0,25 11,1 132,0 189,0 24 16027 3 x 0,75 6,3 50,0 66,0 19
20045 32 x 0,25 11,5 138,0 204,0 24 16028 4 x 0,75 6,8 57,0 77,0 19
20046 36 x 0,25 11,9 146,0 219,0 24 16029 5 x 0,75 7,4 70,0 93,0 19
20087 37 x 0,25 11,9 152,0 230,0 24 16030 6 x 0,75 8,2 87,0 113,0 19
20047 40 x 0,25 12,9 157,0 247,0 24 16031 7 x 0,75 8,2 96,0 130,0 19
20048 42 x 0,25 13,0 160,0 269,0 24 16032 8 x 0,75 9,7 110,0 145,0 19
20049 44 x 0,25 13,7 164,0 292,0 24 16033 10 x 0,75 10,3 140,0 180,0 19
20050 48 x 0,25 13,9 164,0 317,0 24 16034 12 x 0,75 10,5 151,0 202,0 19
20051 52 x 0,25 14,3 175,0 330,0 24 16035 14 x 0,75 11,3 167,0 225,0 19
20052 56 x 0,25 14,7 189,0 343,0 24 16036 16 x 0,75 11,9 183,0 275,0 19
20053 61 x 0,25 15,2 204,0 365,0 24 16037 18 x 0,75 12,7 207,0 292,0 19
20054 80 x 0,25 17,2 387,0 480,0 24 16529 19 x 0,75 12,7 221,0 322,0 19
20055 100 x 0,25 19,4 505,0 605,0 24 16038 20 x 0,75 13,6 238,0 362,0 19
20088 1 x 0,34 3,2 13,5 24,0 22 16039 24 x 0,75 14,9 270,0 435,0 19
20056 2 x 0,34 4,9 18,0 30,0 22 16040 25 x 0,75 15,0 278,0 415,0 19
20057 3 x 0,34 5,1 22,0 37,0 22 16041 27 x 0,75 15,1 287,0 467,0 19
20058 4 x 0,34 5,5 28,0 48,0 22 16042 30 x 0,75 16,0 315,0 486,0 19
20059 5 x 0,34 6,0 31,0 54,0 22 16043 32 x 0,75 16,5 330,0 530,0 19
20085 6 x 0,34 6,6 45,0 61,0 22 16163 34 x 0,75 17,7 350,0 570,0 19
20060 7 x 0,34 6,6 51,0 67,0 22 16044 36 x 0,75 17,4 370,0 600,0 19
20061 8 x 0,34 7,7 54,0 81,0 22 16530 37 x 0,75 17,4 386,0 640,0 19
20062 10 x 0,34 8,4 65,0 103,0 22 16045 40 x 0,75 18,7 395,0 680,0 19
20063 12 x 0,34 8,6 70,0 110,0 22 16120 42 x 0,75 18,9 408,0 714,0 19
20064 14 x 0,34 9,0 81,0 153,0 22 16047 61 x 0,75 22,0 555,0 900,0 19
20065 16 x 0,34 9,6 88,0 159,0 22 16048 80 x 0,75 25,3 715,0 1200,0 19
20066 18 x 0,34 10,1 103,0 172,0 22 16049 100 x 0,75 28,0 910,0 1440,0 19
20089 19 x 0,34 10,1 106,0 181,0 22 16475 2x1 6,4 46,0 65,0 18
20067 20 x 0,34 10,8 112,0 191,0 22 16476 3x1 6,7 56,0 80,0 18
20068 21 x 0,34 10,9 116,0 199,0 22 16477 4x1 7,2 69,0 98,0 18
20069 24 x 0,34 11,7 129,0 229,0 22 16478 5x1 8,0 89,0 127,0 18
20093 25 x 0,34 12,0 120,0 241,0 22 16479 6x1 8,7 105,0 144,0 18
20070 27 x 0,34 12,1 138,0 258,0 22 16480 7x1 8,7 111,0 158,0 18
20071 30 x 0,34 12,6 158,0 290,0 22 16481 8x1 10,3 130,0 197,0 18
20072 32 x 0,34 13,0 163,0 305,0 22 16482 10 x 1 11,2 140,0 232,0 18
20073 36 x 0,34 13,8 178,0 330,0 22 16483 12 x 1 11,4 168,0 260,0 18
20090 37 x 0,34 13,8 192,0 348,0 22 16484 14 x 1 12,0 198,0 302,0 18
20074 40 x 0,34 14,8 198,0 364,0 22 16485 16 x 1 12,8 218,0 346,0 18
20075 42 x 0,34 14,9 203,0 389,0 22 16486 19 x 1 13,6 268,0 412,0 18
20076 44 x 0,34 15,6 214,0 414,0 22 16487 24 x 1 16,0 320,0 493,0 18
20077 48 x 0,34 15,8 227,0 420,0 22 16488 27 x 1 16,4 360,0 562,0 18
20078 52 x 0,34 16,3 242,0 450,0 22 16489 37 x 1 18,6 485,0 790,0 18
20079 56 x 0,34 16,8 267,0 480,0 22 16500 2 x 1,5 7,0 63,0 88,0 16
20080 61 x 0,34 17,2 295,0 520,0 22 16501 3 x 1,5 7,4 76,0 100,0 16
20081 80 x 0,34 19,6 524,0 580,0 22 16502 4 x 1,5 8,1 98,0 126,0 16
20082 100 x 0,34 21,9 620,0 694,0 22 16503 5 x 1,5 9,0 116,0 160,0 16
16001 1 x 0,5 3,5 15,0 40,0 20 16504 6 x 1,5 9,8 140,0 192,0 16
16002 2 x 0,5 5,3 29,0 45,0 20 16505 7 x 1,5 9,8 152,0 208,0 16
16003 3 x 0,5 5,6 39,0 55,0 20 16506 8 x 1,5 11,0 172,0 244,0 16
16004 4 x 0,5 6,3 46,0 61,0 20 16507 10 x 1,5 12,6 193,0 315,0 16
16005 5 x 0,5 6,8 52,0 76,0 20 16508 12 x 1,5 12,8 254,0 338,0 16
16006 6 x 0,5 7,3 66,0 89,0 20 16509 14 x 1,5 13,5 272,0 383,0 16
16007 7 x 0,5 7,3 68,0 98,0 20 16510 16 x 1,5 14,6 285,0 424,0 16
16008 8 x 0,5 8,6 80,0 117,0 20 16511 19 x 1,5 15,6 387,0 506,0 16
16009 10 x 0,5 9,4 93,0 135,0 20 16512 24 x 1,5 18,1 448,0 690,0 16
16010 12 x 0,5 9,6 117,0 157,0 20 16513 27 x 1,5 18,7 506,0 781,0 16
16011 14 x 0,5 10,1 122,0 190,0 20 16514 37 x 1,5 21,4 682,0 941,0 16

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Cable tie

132
Data and Computer Cables

PAAR-TRONIC-CY EMC-preferred type, flexible, Cu-screened, colour coded


to DIN 47100, meter marking

Technical data Cable structure Properties


Special PVC data cables for electronic Bare copper-conductor, from 0,5 mm to Extensively oil resistant, oil-/ chemical
control adapted to DIN VDE 0812 DIN VDE 0295 cl.5, fine-wire, Resistance - see table Technical
and 0814 BS 6360 cl.5, IEC 60228 cl.5 Informations
Temperature range Conductor construction: The materials used in manufacture are
flexing -5C to +80C 0,14 mm = 18x0,1 mm cadmium-free and contain no silicone
fixed installation -30C to +80C 0,25 mm = 14x0,15 mm and free from substances harmful to
Operating peak voltage 350 V 0,34 mm = 7x0,25 mm the wetting properties of lacquers
(not for heavy current installation Core insulation of special PVC Tests
purposes) compound type TI2 to PVC self-extinguishing and flame retardant
Test voltage DIN VDE 0207-363-3 / DIN EN 50363-3 acc. to DIN VDE 0482-332-1-2,
core/core 1200 V Core identification (pair) to DIN 47100 DIN EN 60332-1-2, IEC 60332-1 (equivalent
core/screen 800 V Cores stranded in pairs with DIN VDE 0472 part 804 test method B)
Breakdown voltage min. 2400 V optimal lay-length
Insulation resistance Pairs stranded in layers with Note
min. 20 MOhm x km optimal lay-length AWG sizes are approximate equivalent
Plant capacity (approx.-value) at 800 Hz Foil wrapping values. The actual cross-section is in mm.
core/core 0,14 mm = 120 pF/m Drain wire, tinned unscreened analogue type:
core/core 0,25 mm = 150 pF/m Tinned copper braided screen, PAAR-TRONIC, confer page 126
core/screen 0,14 mm = 240 pF/m approx. 85% coverage
core/screen 0,25 mm = 270 pF/m Outer sheath of special PVC
Inductance approx. 0,65 mH/km compound type TM2 to
Impedance approx. 78 Ohm DIN VDE 0207-363-4-1/DIN EN 50363-4-1
K1-coupling approx. 300 pF/100 m Sheath colour grey (RAL 7032)
Coupling resistance also available in other colours on request
max.250 Ohm/km with meter marking
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but
not suitable for open air. PAAR-TRONIC-CY is well suited for use in areas subject to signal interference. The high level of screening reduces substantially
the effects of electrical disturbances from parallel running wiring etc. The copper screening is also often used as an "earth". The twisted pairs conform
favourable cross-talk attenuation values.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21001 1 x 2 x 0,14 4,0 15,6 34,0 26 21006 6 x 2 x 0,14 7,2 48,5 86,0 26
21002 2 x 2 x 0,14 5,0 18,5 40,0 26 21007 7 x 2 x 0,14 7,2 51,1 91,0 26
21003 3 x 2 x 0,14 5,7 23,0 49,0 26 21008 8 x 2 x 0,14 8,2 53,7 97,0 26
21004 4 x 2 x 0,14 6,1 26,6 55,0 26 21009 10 x 2 x 0,14 9,1 59,0 109,0 26
21005 5 x 2 x 0,14 6,8 30,7 66,0 26 21010 12 x 2 x 0,14 9,6 66,0 141,0 26

Continuation

133
Data and Computer Cables

PAAR-TRONIC-CY EMC-preferred type, flexible, Cu-screened, colour coded


to DIN 47100, meter marking
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21011 14 x 2 x 0,14 10,4 74,0 148,0 26 19972 3 x 2 x 0,34 7,2 44,9 78,0 22
21012 15 x 2 x 0,14 10,6 76,0 152,0 26 19973 4 x 2 x 0,34 8,1 54,2 90,0 22
21013 16 x 2 x 0,14 10,7 79,0 155,0 26 19974 5 x 2 x 0,34 9,0 63,5 110,0 22
21014 18 x 2 x 0,14 11,2 83,0 171,0 26 19975 6 x 2 x 0,34 10,0 73,1 130,0 22
21015 20 x 2 x 0,14 11,4 97,0 183,0 26 19976 7 x 2 x 0,34 10,0 79,5 145,0 22
21016 22 x 2 x 0,14 12,3 103,0 205,0 26 19977 8 x 2 x 0,34 10,8 88,4 150,0 22
21017 24 x 2 x 0,14 12,8 111,0 228,0 26 19978 9 x 2 x 0,34 11,1 99,3 170,0 22
21018 25 x 2 x 0,14 12,9 113,0 239,0 26 19979 10 x 2 x 0,34 12,2 106,9 190,0 22
21019 26 x 2 x 0,14 13,0 122,0 245,0 26 19980 12 x 2 x 0,34 12,9 122,1 220,0 22
21020 27 x 2 x 0,14 13,1 125,0 251,0 26 19981 14 x 2 x 0,34 13,9 138,2 245,0 22
21021 28 x 2 x 0,14 14,0 128,0 258,0 26 19982 16 x 2 x 0,34 14,5 154,2 250,0 22
21022 30 x 2 x 0,14 14,1 140,0 270,0 26 19983 18 x 2 x 0,34 15,3 197,9 275,0 22
21023 32 x 2 x 0,14 14,8 145,0 284,0 26 19984 21 x 2 x 0,34 16,3 214,4 300,0 22
21024 34 x 2 x 0,14 14,9 150,0 300,0 26 19985 25 x 2 x 0,34 17,6 238,5 400,0 22
21025 36 x 2 x 0,14 15,6 156,0 316,0 26 19986 27 x 2 x 0,34 18,0 262,5 410,0 22
21026 38 x 2 x 0,14 16,4 162,0 350,0 26 19987 30 x 2 x 0,34 19,5 286,6 440,0 22
21027 40 x 2 x 0,14 16,8 177,0 370,0 26 19988 34 x 2 x 0,34 20,8 310,1 510,0 22
21028 44 x 2 x 0,14 17,0 181,0 390,0 26 19989 37 x 2 x 0,34 21,4 368,7 550,0 22
21029 46 x 2 x 0,14 17,2 195,0 430,0 26 19990 40 x 2 x 0,34 22,1 392,6 590,0 22
21030 50 x 2 x 0,14 18,0 202,0 440,0 26 19991 44 x 2 x 0,34 23,0 424,3 600,0 22
21031 52 x 2 x 0,14 18,2 206,0 460,0 26 19992 50 x 2 x 0,34 24,5 455,9 650,0 22
21032 55 x 2 x 0,14 18,7 210,0 480,0 26 19993 52 x 2 x 0,34 24,7 487,6 680,0 22
21033 1 x 2 x 0,25 4,4 15,0 45,0 24 19994 56 x 2 x 0,34 26,1 518,5 750,0 22
21034 2 x 2 x 0,25 5,8 28,0 53,0 24 19995 61 x 2 x 0,34 27,5 557,2 840,0 22
21035 3 x 2 x 0,25 6,4 32,0 65,0 24 17047 1 x 2 x 0,5 5,3 24,0 60,0 20
21036 4 x 2 x 0,25 7,2 38,0 80,0 24 17001 2 x 2 x 0,5 7,6 54,0 89,0 20
21037 5 x 2 x 0,25 8,1 55,0 98,0 24 17002 3 x 2 x 0,5 8,2 70,0 104,0 20
21038 6 x 2 x 0,25 8,8 65,0 114,0 24 17003 4 x 2 x 0,5 9,0 91,0 126,0 20
21039 7 x 2 x 0,25 8,8 70,0 121,0 24 17004 5 x 2 x 0,5 9,9 105,0 148,0 20
21040 8 x 2 x 0,25 9,4 75,0 129,0 24 17005 6 x 2 x 0,5 10,9 120,0 171,0 20
21041 10 x 2 x 0,25 10,8 110,0 157,0 24 17006 8 x 2 x 0,5 12,0 144,0 290,0 20
21042 12 x 2 x 0,25 11,4 117,0 189,0 24 17007 10 x 2 x 0,5 13,8 178,0 320,0 20
21043 14 x 2 x 0,25 12,0 122,0 213,0 24 17008 12 x 2 x 0,5 14,5 199,0 361,0 20
21044 15 x 2 x 0,25 12,5 134,0 225,0 24 17009 16 x 2 x 0,5 16,1 254,0 421,0 20
21045 16 x 2 x 0,25 12,6 143,0 237,0 24 17010 20 x 2 x 0,5 18,4 302,0 580,0 20
21046 18 x 2 x 0,25 13,3 148,0 248,0 24 17011 25 x 2 x 0,5 21,0 344,0 740,0 20
21047 20 x 2 x 0,25 14,0 162,0 275,0 24 17048 1 x 2 x 0,75 6,0 28,0 71,0 19
21048 22 x 2 x 0,25 15,0 172,0 303,0 24 17012 2 x 2 x 0,75 8,7 58,0 105,0 19
21049 24 x 2 x 0,25 15,7 223,0 330,0 24 17013 3 x 2 x 0,75 9,3 84,0 128,0 19
21050 25 x 2 x 0,25 15,8 233,0 343,0 24 17014 4 x 2 x 0,75 10,6 108,0 156,0 19
21051 26 x 2 x 0,25 15,9 238,0 345,0 24 17015 5 x 2 x 0,75 11,7 126,0 189,0 19
21052 27 x 2 x 0,25 16,0 244,0 350,0 24 17016 6 x 2 x 0,75 12,7 146,0 216,0 19
21053 28 x 2 x 0,25 16,6 249,0 360,0 24 17017 8 x 2 x 0,75 14,4 180,0 309,0 19
21054 30 x 2 x 0,25 17,0 254,0 375,0 24 17018 10 x 2 x 0,75 15,6 220,0 355,0 19
21055 32 x 2 x 0,25 17,6 290,0 400,0 24 17019 12 x 2 x 0,75 16,8 261,0 405,0 19
21056 34 x 2 x 0,25 17,9 312,0 410,0 24 17020 16 x 2 x 0,75 18,7 328,0 565,0 19
21057 36 x 2 x 0,25 18,6 322,0 420,0 24 17021 20 x 2 x 0,75 20,9 392,0 700,0 19
21058 38 x 2 x 0,25 19,0 339,0 450,0 24 17022 25 x 2 x 0,75 23,2 470,0 950,0 19
21059 40 x 2 x 0,25 19,7 349,0 485,0 24 17049 1x2x1 6,3 46,0 75,0 18
21060 44 x 2 x 0,25 20,7 359,0 500,0 24 17050 2x2x1 9,1 82,0 116,0 18
21061 46 x 2 x 0,25 21,2 398,0 540,0 24 17051 3x2x1 9,8 103,0 140,0 18
21062 50 x 2 x 0,25 22,0 403,0 550,0 24 17052 4x2x1 10,9 132,0 191,0 18
21063 52 x 2 x 0,25 22,0 435,0 580,0 24 17053 1 x 2 x 1,5 7,2 63,0 84,0 16
21064 55 x 2 x 0,25 22,5 464,0 630,0 24 17054 2 x 2 x 1,5 10,7 111,0 122,0 16
19970 1 x 2 x 0,34 5,0 16,0 58,0 22 17055 3 x 2 x 1,5 11,4 136,0 194,0 16
19971 2 x 2 x 0,34 6,7 36,9 65,0 22 17056 4 x 2 x 1,5 12,8 172,0 240,0 16

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Cable tie

134
Data and Computer Cables

PAAR-CY-OZ flexible, Cu-screened, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special-PUR control cable adapted Bare copper-conductor, to Extensively oil resistant, oil-/ chemical
to DIN VDE 0812, 0814 DIN VDE 0295 cl.5, fine-wire, Resistance - see table Technical
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Informations
flexing -5C to +80C Core insulation of special PVC The materials used in manufacture are
fixed installation -40C to +80C compound type TI2 to cadmium-free and contain no silicone
Nominal voltage U0/U 300/500 V DIN VDE 0207-363-3 / DIN EN 50363-3 and free from substances harmful to
Test voltage Core identification to DIN VDE 0293 the wetting properties of lacquers
core/core 1200 V black cores with continuous white Tests
core/screen 800 V numbering PVC self-extinguishing and flame retardant
Breakdown voltage min. 2400 V Cores stranded in pairs with acc. to DIN VDE 0482-332-1-2,
Insulation resistance optimal lay-length DIN EN 60332-1-2/IEC 60332-1 (equivalent
min. 20 MOhm x km Pairs stranded in layers with DIN VDE 0472 part 804 test method B)
Mutual capacitance optimal lay-length
core/core approx. 150 nF/km Foil wrapping Note
core/screen approx. 270 nF/km Tinned copper braided screen, x = without green-yellow conductor (OZ)
Inductance approx. 0,67 mH/km approx. 85% coverage Also available in other dimensions and
Coupling resistance Outer sheath of special PVC in other sheath colours.
max. 250 Ohm/km compound type TM2 to AWG sizes are approximate equivalent
Minimum bending radius DIN VDE 0207-363-4-1/DIN EN 50363-4-1 values. The actual cross-section is in mm.
flexing 10x cable Sheath colour grey (RAL 7032)
fixed installation 5x cable with meter marking
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
PAAR-CY is ideal for use as a connecting cable for all areas involving measuring, control, regulation and signal transfer as well as for use in all fields
of data and impulse transmission. Especially suited for all areas of high electromagnetic activity, e. g. disturbances through parallel circuits.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
17023 2x2x1 9,5 82,0 135,0 18 17034 2 x 2 x 1,5 11,3 112,0 168,0 16
17024 3x2x1 10,0 103,0 160,0 18 17035 3 x 2 x 1,5 12,2 139,0 221,0 16
17025 4x2x1 11,0 132,0 197,0 18 17036 4 x 2 x 1,5 13,5 176,0 269,0 16
17026 5x2x1 12,3 161,0 253,0 18 17037 5 x 2 x 1,5 14,5 212,0 314,0 16
17027 6x2x1 13,4 188,0 295,0 18 17038 6 x 2 x 1,5 17,2 255,0 550,0 16
17028 8x2x1 14,7 240,0 410,0 18 17039 8 x 2 x 1,5 17,5 322,0 650,0 16
17029 10 x 2 x 1 16,4 282,0 518,0 18 17040 10 x 2 x 1,5 20,1 380,0 900,0 16
17030 12 x 2 x 1 18,2 324,0 601,0 18 17041 12 x 2 x 1,5 21,8 442,0 950,0 16
17031 16 x 2 x 1 19,0 412,0 990,0 18 17042 16 x 2 x 1,5 25,0 572,0 1100,0 16
17032 20 x 2 x 1 19,8 505,0 1400,0 18 17043 20 x 2 x 1,5 27,0 705,0 1700,0 16
17033 25 x 2 x 1 23,5 610,0 1600,0 18 17044 25 x 2 x 1,5 29,5 862,0 1900,0 16

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Cable tie

135
Data and Computer Cables

PAAR-TRONIC-CY-CY (LiYCY-CY) EMC-preferred type,


meter marking

Technical data Cable structure Properties


Special PVC data transmission cable Bare copper, fine wire conductors, to Extensively oil resistant, oil-/ chemical
adapted to DIN VDE 0812 and 0814 DIN VDE 0295 cl.5 Resistance - see table Technical
Temperature range Conductor construction: Informations
flexing -5C to +80C 0,14 mm = 18x0,1 mm The materials used in manufacture are
fixed installation -40C to +80C 0,25 mm = 14x0,15 mm cadmium-free and contain no silicone
Operating peak voltage 0,34 mm = 7x0,25 mm and free from substances harmful to
(not for heavy current installation purposes) Core insulation of special PVC the wetting properties of lacquers
0,14 mm = max. 350 V compound type TI2 to Tests
0,25 mm = max. 500 V DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
Test voltage Core identification (pair) to DIN 47100 acc. to DIN VDE 0482-332-1-2,
0,14 mm = 1200 V Cores stranded in pairs with DIN EN 60332-1-2, IEC 60332-1 (equivalent
0,25 mm = 2000 V optimal lay-length DIN VDE 0472 part 804 test method B)
Breakdown voltage Pairs screened individually, tinned copper,
0,14 mm = 2400 V coverage approx. 85% Note
0,25 mm = 4000 V Special PVC coating over individual screened As of 0,75 mm cross-sec. see type
Mutual capacitance pairs all pairs-CY stranded together EDV-PiMF-CY.
core/core Foil wrapping AWG sizes are approximate equivalent
0,14 mm = 147 pF/m Overall braid-screening, tinned copper values. The actual cross-section is in mm.
0,25 mm = 152,5 pF/m coverage approx. 85%
core/screen Outer sheath of special PVC
0,14 mm = 147 pF/m compound type TM2 to
0,25 mm = 263 pF/m DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Impedance Sheath colour grey (RAL 7001)
0,14 mm = 536 Ohm/1 kHz/20C with meter marking
0,25 mm = 396 Ohm/1 kHz/20C
Coupling 250 pF/100 m/1 kHz
Screen resistance
0,14 mm = 36 Ohm/km
0,25 mm = 18 Ohm/km
Attenuation
0,14 mm = 3,6 dB/1 kHz/km
0,25 mm = 2,2 dB/1 kHz/km
Coupling resistance
max. 250 Ohm/km
Minimum bending radius
flexing 12x cable
fixed installation 6x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
As a control and signal cable in electronics, instrumentation and control technology. Interference free transmission of data signals from peripheral
devices to information storage. Excellent connecting cable for mixing console, studio equipment, measuring and control technology. Reliable in process
control, in machining centers and safety engineering systems. These cables with copper screening are suitable for interference free data and signal
transmission in the measurement, control and regulation technology.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21065 2 x 2 x 0,14 7,6 31,0 95,0 26 21071 8 x 2 x 0,14 12,0 97,0 245,0 26
21066 3 x 2 x 0,14 8,4 34,0 105,0 26 21072 9 x 2 x 0,14 13,0 101,0 280,0 26
21067 4 x 2 x 0,14 9,9 45,0 140,0 26 21073 10 x 2 x 0,14 14,1 108,0 325,0 26
21068 5 x 2 x 0,14 10,4 58,0 160,0 26 21074 12 x 2 x 0,14 15,2 134,0 380,0 26
21069 6 x 2 x 0,14 11,0 67,0 185,0 26 21075 16 x 2 x 0,14 16,7 179,0 440,0 26
21070 7 x 2 x 0,14 11,0 78,0 230,0 26 21076 20 x 2 x 0,14 18,4 225,0 520,0 26

Continuation

136
Data and Computer Cables

PAAR-TRONIC-CY-CY (LiYCY-CY) EMC-preferred type,


meter marking
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21077
21078
2 x 2 x 0,25
3 x 2 x 0,25
8,6
9,3
62,0
78,2
125,0
140,0
24
24
21101
21102
2 x 2 x 0,5
3 x 2 x 0,5
10,4
11,7
83,1
106,4
143,0
179,0
20
20 B
21079 4 x 2 x 0,25 10,4 124,1 205,0 24 21103 4 x 2 x 0,5 13,1 158,0 241,0 20
21080 5 x 2 x 0,25 12,1 137,6 230,0 24 21104 6 x 2 x 0,5 15,6 201,4 319,0 20
21081 6 x 2 x 0,25 13,9 148,1 275,0 24 21105 8 x 2 x 0,5 16,4 311,5 441,0 20
21082 7 x 2 x 0,25 13,9 159,1 295,0 24 21106 10 x 2 x 0,5 20,6 334,5 464,0 20
21083 8 x 2 x 0,25 14,2 178,7 330,0 24 21107 12 x 2 x 0,5 21,5 394,1 529,0 20
21084 10 x 2 x 0,25 15,9 213,9 420,0 24 21108 14 x 2 x 0,5 21,6 446,0 641,0 20
21085 12 x 2 x 0,25 17,0 238,3 465,0 24 21109 16 x 2 x 0,5 23,8 501,2 694,0 20
21086 16 x 2 x 0,25 19,8 291,4 590,0 24 21110 24 x 2 x 0,5 28,4 712,4 930,0 20
21087 20 x 2 x 0,25 21,2 325,0 620,0 24
21088 24 x 2 x 0,25 24,0 367,5 690,0 24
21089 32 x 2 x 0,25 26,5 588,0 785,0 24
21090 48 x 2 x 0,25 31,6 840,5 970,0 24
21091 2 x 2 x 0,34 9,5 73,1 139,0 22
21092 3 x 2 x 0,34 10,5 88,1 157,0 22
21093 4 x 2 x 0,34 11,3 137,2 213,0 22
21094 6 x 2 x 0,34 13,9 174,8 308,0 22
21095 8 x 2 x 0,34 15,4 247,2 385,0 22
21096 10 x 2 x 0,34 17,6 288,7 433,0 22
21097 12 x 2 x 0,34 18,3 321,0 495,0 22
21098 14 x 2 x 0,34 19,6 388,4 600,0 22
21099 16 x 2 x 0,34 20,9 425,5 637,0 22
21100 24 x 2 x 0,34 26,1 577,1 781,0 22

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Cable tie

137
Data and Computer Cables

PAAR-TRONIC-Li-2YCYv PE-insulated, low capacitance, Termi-Point,


EMC-preferred type, meter marking

Technical data Cable structure Properties


PE-insulated data cable Bare copper-conductor, 7-wires, adapted to The line offers enormous advantages
Temperature range DIN VDE 0881, suitable for Termi-Point through fast and cheap contacting possibilty
flexing -5C to +70C and solder-free connection technique in Termi-Point connection technology. With

fixed installation -30C to +80C Conductor construction: this solder-free connection technique, the
Conductor resistance (loop) at 20C 0,22 mm = 7x0,2 mm stranded conductor is crimped together with
0,22 mm max. 186 Ohm/km 0,34 mm = 7x0,25 mm a sleeve onto a contact pin without prior
0,34 mm max. 115 Ohm/km 0,5 mm = 7x0,3 mm stripping of the insulation material
0,5 mm max. 78,5 Ohm/km 1 mm = 7 x 0,42 mm The twisted-pair lay-up prevents electrical
1,0 mm max. 39,2 Ohm/km Core insulation of PE unbalances within the cable and this thus
Operating peak voltage max. 250 V compound type L/MD to effectively suppresses cross-talking effects
(not for heavy current installation purposes) DIN VDE 0819-103 /DIN EN 50290-2-23 The materials used in manufacture are
Test voltage Core identification (pair) to DIN 47100 cadmium-free and contain no silicone
core/core 2000 V Cores stranded in pairs with and free from substances harmful to
core/screen 1000 V optimal lay-length the wetting properties of lacquers
Insulation resistance min. 5 GOhm x km Pairs stranded in layers with Tests
Mutual capacitance at 800 Hz optimal lay-length PVC outer sheath self-extinguishing and
> 4 pairs max. 60 nF/km Foil wrapping flame retardant acc. to DIN VDE
4 pairs values extended by 20% Tinned copper braided screening, 0482-332-1-2,
Inductance approx. 0,66 mH/km coverage approx. 85% DIN EN 60332-1-2, IEC 60332-1 (equivalent
Line attenuation (approx. value) Outer sheath of special PVC DIN VDE 0472 part 804 test method B)
0,22 mm at 100 kHz 9,0 dB/km compound type TM2 to
0,34 mm at 100 kHz 6,6 dB/km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 Note
0,50 mm at 100 kHz 6,0 dB/km Type . . . Yv with reinforced outer sheath At 0,22 mm is designed for applications
0,22 mm at 1 MHz 25,0 dB/km Sheath colour black with Sub-D connectors.
0,34 mm at 1 MHz 20,0 dB/km with meter marking Termi-Point registered trade mark AMP.
0,50 mm at 1 MHz 18,0 dB/km AWG sizes are approximate equivalent
Cross-talk attenuation values. The actual cross-section is in mm.
up to 1 MHz min. 50 dB
up to 10 MHz min. 40 dB
Minimum bending radius
flexing 12x cable
fixed installation 7,5x cable

Application
These PE-insulated data cables with twisted pairs are used in particular for the interference-free transmission of data and signals over longer distances.
The high transmission rates are particularly suitable for RS 422 and RS 485 interfaces. These cables are suitable for fixed installations as well as for
flexing applications, for free movement without forced motion and without tensile stress, in dry and moist environments. Yv black with reinforced
outer sheath, is suitable for installation in the ground and in open air.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21129 2 x 2 x 0,22 7,8 26,0 60,0 24 21141 2 x 2 x 0,5 9,8 49,0 90,0 20
21130 3 x 2 x 0,22 8,1 31,0 79,0 24 21142 3 x 2 x 0,5 10,4 60,0 126,0 20
21131 4 x 2 x 0,22 8,5 38,0 96,0 24 21143 4 x 2 x 0,5 11,2 73,0 146,0 20
21132 8 x 2 x 0,22 10,6 62,0 140,0 24 21144 8 x 2 x 0,5 13,9 124,0 246,0 20
21133 10 x 2 x 0,22 11,6 79,0 184,0 24 21145 10 x 2 x 0,5 16,0 155,0 292,0 20
21135 2 x 2 x 0,34 8,7 35,0 83,0 22 21146 2x2x1 10,8 81,0 141,0 18
21136 3 x 2 x 0,34 9,4 44,0 92,0 22 21147 3x2x1 11,5 102,0 170,0 18
21137 4 x 2 x 0,34 10,0 53,0 112,0 22 21148 4x2x1 12,0 130,0 203,0 18
21138 8 x 2 x 0,34 12,4 86,0 179,0 22 21149 8x2x1 16,1 240,0 261,0 18
21139 10 x 2 x 0,34 13,8 104,0 219,0 22 21150 10 x 2 x 1 17,2 282,0 287,0 18

Dimensions and specifications may be changed without prior notice. (RB01)

138
Data and Computer Cables

PAAR-TRONIC-Li-2YCY PE-insulated, low capacitance, Termi-Point,


EMC-preferred type, meter marking

Technical data Cable structure Properties


PE-insulated data cable Bare copper-conductor, 7-wires, adapted to These cables make enormous advantages
Temperature range DIN VDE 0881, suitable for Termi-Point possible for fast and cost-effective
flexing -5C to +70C and solder-free connection technique contact-making using the Termi-Point
fixed installation -30C to +80C Conductor construction: connection technique. With this solder-free
Conductor resistance (loop) at 20C 0,22 mm = 7x0,2 mm connection technique, the stranded
0,22 mm max. 186 Ohm/km 0,34 mm = 7x0,25 mm conductor is crimped together with a
0,34 mm max. 115 Ohm/km 0,5 mm = 7x0,3 mm sleeve onto a contact pin without prior
0,5 mm max. 78,5 Ohm/km Core insulation of PE stripping of the insulation material
Operating peak voltage max. 250 V compound type L/MD to The twisted-pair lay-up prevents electrical
(not for heavy current installation purposes) DIN VDE 0819-103/DIN EN 50290-2-23 unbalances within the cable and this thus
Test voltage Core identification (pair) to DIN 47100 effectively suppresses cross-talking effects
core/core 2000 V Cores stranded in pairs with The materials used in manufacture are
core/screen 1000 V optimal lay-length cadmium-free and contain no silicone
Insulation resistance min. 5 GOhm x km Pairs stranded in layers with and free from substances harmful to
Mutual capacitance at 800 Hz optimal lay-length the wetting properties of lacquers
> 4 pairs max. 60 nF/km Foil wrapping Tests
4 pairs values extended by 20% Tinned copper braided screen, PVC outer sheath self-extinguishing and
Inductance approx. 0,66 mH/km approx. 85% coverage flame retardant acc. to DIN VDE
Line attenuation (approx. value) Outer sheath of special PVC 0482-332-1-2,
0,22 mm at 100 kHz 9,0 dB/km compound type TM2 to DIN EN 60332-1-2, IEC 60332-1 (equivalent
0,34 mm at 100 kHz 6,6 dB/km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 DIN VDE 0472 part 804 test method B)
0,50 mm at 100 kHz 6,0 dB/km Sheath colour grey
0,22 mm at 1 MHz 25,0 dB/km with meter marking Note
0,34 mm at 1 MHz 20,0 dB/km At 0,22 mm is designed for applications
0,50 mm at 1 MHz 18,0 dB/km with Sub-D connectors.
Cross-talk attenuation Termi-Point registered trade mark AMP.
up to 1 MHz min. 50 dB AWG sizes are approximate equivalent
up to 10 MHz min. 40 dB values. The actual cross-section is in mm.
Minimum bending radius
flexing 12x cable
fixed installation 7,5x cable

Application
These PE-insulated data cables with twisted pairs are used in particular for the interference-free transmission of data and signals over longer distances.
The high transmission rates are particularly suitable for RS 422 and RS 485 interfaces. These cables are suitable for fixed installations as well as for
flexing applications, for free movement without forced motion and without tensile stress, in dry and moist environments but not in open air (Type
grey).
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No.


cross-sec. approx. mm weight approx.
mm kg / km kg / km
21111 2 x 2 x 0,22 5,5 26,0 48,0 24
21112 3 x 2 x 0,22 6,2 31,0 66,0 24
21113 4 x 2 x 0,22 6,5 38,0 82,0 24
21114 8 x 2 x 0,22 8,6 62,0 123,0 24
21115 10 x 2 x 0,22 9,9 79,0 165,0 24
21117 2 x 2 x 0,34 6,7 35,0 68,0 22
21118 3 x 2 x 0,34 7,2 44,0 77,0 22
21119 4 x 2 x 0,34 8,0 53,0 95,0 22
21120 8 x 2 x 0,34 10,9 86,0 158,0 22
21121 10 x 2 x 0,34 12,5 104,0 195,0 22
21123 2 x 2 x 0,5 7,9 49,0 74,0 20
21124 3 x 2 x 0,5 8,6 60,0 109,0 20
21125 4 x 2 x 0,5 9,6 73,0 128,0 20
21126 8 x 2 x 0,5 12,8 124,0 223,0 20
21127 10 x 2 x 0,5 14,8 155,0 265,0 20

Dimensions and specifications may be changed without prior notice. (RB01)

139
Data and Computer Cables

LifYCY high flexible, paired, screened, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special PVC connecting cable, adapted Bare copper, extra fine conductors Extensively oil resistant, oil-/ chemical
to DIN VDE 0812 and 0814 (single wire diameter 0,05 mm) Resistance - see table Technical
Temperature range Core insulation of special PVC Informations
flexing -5C to +70C compound type TI2 to The materials used in manufacture are
fixed installation -40C to +70C DIN VDE 0207-363-3 / DIN EN 50363-3 cadmium-free and contain no silicone
Operating peak voltage 350 V Core identification (pair) to DIN 47100 and free from substances harmful to
(not for heavy current installation purposes) Cores stranded in pairs the wetting properties of lacquers
Test voltage 1200 V Pairs stranded in layers Tests
Breakdown voltage min. 2400 V Foil wrapping PVC self-extinguishing and flame retardant
Insulation resistance Tinned copper braided screen, acc. to DIN VDE 0482-332-1-2,
min. 10 MOhm x km approx. 85% coverage DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius Outer sheath of special PVC DIN VDE 0472 part 804 test method B)
flexing 10x cable compound type TM2 to
fixed installation 5x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Radiation resistance Sheath colour grey (RAL 7032)
up to 80x106 cJ/kg (up to 80 Mrad) with meter marking
Coupling resistance
max. 250 Ohm/km

Application
These screened cables are used as connecting cable for signal, measuring, control and speaking purposes for example in Intercom systems, weighing
instruments, equipment for office works, computers and telecommunication equipment etc. The cable offers a flexible handling and installation. Due
to pair-twisting, the electrical unbalances of the cable itself can be reduced and cross-talk effects are avoided. The tinned copper screened braiding
serves as protection against outer high frequency influences (capacitance unbalance). The drain wire ensure an exact connection to the earth clamp.
The cables are suitable for fixed installation and flexible application, free-moving without tensile stress and without forced guiding operation in dry,
damp and wet places for medium mechanical stress.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15987 2 x 2 x 0,2 5,7 24,0 60,0 - 15994 10 x 2 x 0,2 10,2 108,0 150,0 -
15988 3 x 2 x 0,2 6,1 35,0 70,0 - 15995 12 x 2 x 0,2 10,9 125,0 180,0 -
15989 4 x 2 x 0,2 6,6 45,0 80,0 - 15996 16 x 2 x 0,2 12,3 144,0 210,0 -
15990 5 x 2 x 0,2 7,9 54,0 90,0 - 15997 18 x 2 x 0,2 13,1 155,0 230,0 -
15991 6 x 2 x 0,2 8,3 56,0 100,0 - 15998 20 x 2 x 0,2 13,2 216,0 250,0 -
15992 7 x 2 x 0,2 8,3 68,0 120,0 - 15999 24 x 2 x 0,2 15,0 228,0 330,0 -
15993 8 x 2 x 0,2 9,4 72,0 130,0 - 16000 32 x 2 x 0,2 16,6 269,0 400,0 -

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Cable tie

140
Data and Computer Cables

TRONIC 1-CY each core individually screened, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special-PVC core insulation Bare copper-conductor, from 0,5 mm to Extensively oil resistant, oil-/ chemical
adapted to DIN VDE 0812 DIN VDE 0295 cl.5, fine-wire, Resistance - see table Technical
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Informations
flexing -5C to +80C Conductor construction: The materials used in manufacture are
fixed installation -40C to +80C 0,25 mm = 14x0,15 mm cadmium-free and contain no silicone
Operating peak voltage 0,50 mm = 16x0,2 mm and free from substances harmful to
(not for heavy current installation purposes) Core insulation of special PVC the wetting properties of lacquers
0,25 mm 250 V compound type TI2 to Tests
0,50 mm 350 V DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
Test voltage (core/screen) Core identification to DIN 47100 acc. to DIN VDE 0482-332-1-2,
0,25 mm 800 V Each core individually with copper spiral DIN EN 60332-1-2, IEC 60332-1 (equivalent
0,50 mm 1200 V shield, approx. 85% coverage DIN VDE 0472 part 804 test method B)
Insulation resistance Contact protection, PVC sheath
min. 20 MOhm x km Cores stranded in layers with Note
Minimum bending radius optimal lay-length AWG sizes are approximate equivalent
flexing 10x cable Outer sheath of special PVC values. The actual cross-section is in mm.
fixed installation 5x cable compound type TM2 to
Radiation resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour grey (RAL 7001)
with meter marking

Application
The individually screened, flexible cable is ideal for use in data and impulse transfer in computers, communication systems and external units and
offers interference-free data flow for all measuring and command functions. This cable type is widely used in the machine and steel producing industries
as well as for traffic signals and data processing areas.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49501 3 x 0,25 6,5 18,0 40,0 24 49512 3 x 0,5 7,3 28,8 71,0 20
49502 4 x 0,25 7,2 24,0 45,0 24 49513 4 x 0,5 8,2 38,5 81,0 20
49503 5 x 0,25 8,0 30,0 56,0 24 49514 5 x 0,5 9,2 48,0 95,0 20
49504 7 x 0,25 8,8 42,0 70,0 24 49515 7 x 0,5 10,0 67,0 115,0 20
49505 8 x 0,25 10,0 48,0 87,0 24 49516 8 x 0,5 11,0 77,0 145,0 20
49506 10 x 0,25 11,3 60,0 90,0 24 49517 10 x 0,5 13,2 96,0 169,0 20
49507 12 x 0,25 12,0 72,0 95,0 24 49518 12 x 0,5 14,0 114,6 185,0 20
49508 16 x 0,25 13,1 96,0 115,0 24 49519 16 x 0,5 15,5 154,0 225,0 20
49509 24 x 0,25 16,0 144,0 170,0 24 49520 32 x 0,5 21,5 308,0 440,0 20
49510 32 x 0,25 18,5 192,0 210,0 24
49511 48 x 0,25 23,5 288,0 320,0 24

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Cable tie

141
Data and Computer Cables

TRONIC 2-CY 2 cores screened, meter marking

Technical data Cable structure Properties


Special-PVC core insulation Bare copper-conductor, from 0,5 mm to Extensively oil resistant, oil-/ chemical
adapted to DIN VDE 0812 DIN VDE 0295 cl.5, fine-wire, Resistance - see table Technical
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Informations
flexing -5C to +80C 0,14 and 0,25 mm to DIN VDE 0812 The materials used in manufacture are
fixed installation -40C to +80C Conductor construction: cadmium-free and contain no silicone
Conductor resistance 0,14 mm = 18x0,1 mm and free from substances harmful to
0,14 mm = max. 138 Ohm/km 0,25 mm = 14x0,15 mm the wetting properties of lacquers
0,25 mm = max. 77,8 Ohm/km 0,50 mm = 16x0,2 mm Tests
0,50 mm = max. 37,8 Ohm/km Core insulation of special PVC PVC self-extinguishing and flame retardant
Operating peak voltage compound type TI2 to acc. to DIN VDE 0482-332-1-2,
(not for heavy current installation purposes) DIN VDE 0207-363-3 / DIN EN 50363-3 DIN EN 60332-1-2, IEC 60332-1 (equivalent
0,14 mm = max. 350 V Core identification to DIN 47100 DIN VDE 0472 part 804 test method B)
0,25 mm = max. 500 V White and brown cores each individually
0,50 mm = max. 500 V screened Note
Test voltage (50 Hz eff) Copper braided screen, AWG sizes are approximate equivalent
0,14 mm = 800 V approx. 85% coverage values. The actual cross-section is in mm.
0,25 mm = 800 V Cores stranded in layers with
0,50 mm = 1200 V optimal lay-length
Breakdown voltage Contact protection, PVC sheath
0,14 mm = 1600 V Outer sheath of special PVC
0,25 mm = 1600 V compound type TM2 to
0,50 mm = 2400 V DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Insulation resistance Sheath colour grey (RAL 7001)
min. 200 MOhm x km with meter marking
Mutual capacitance (approx.-value)
core/core
0,14 mm = 70 pF/m
0,25 mm = 80 pF/m
0,50 mm = 80 pF/m
core/screen
0,14 mm = 270 pF/m
0,25 mm = 350 pF/m
0,50 mm = 400 pF/m
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
TRONIC 2-CY is used in all areas of measuring and control technology requiring only 2 impulse transfer cores. This cable type is used mainly in the
machinery and industrial equipment fields as well as in the steel industry and in electronics.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49521 4 x 0,14 6,2 14,6 40,0 26 49531 4 x 0,5 7,6 34,0 100,0 20
49522 8 x 0,14 7,2 20,3 50,0 26 49532 8 x 0,5 11,6 53,2 150,0 20
49523 12 x 0,14 8,4 26,8 70,0 26 49533 12 x 0,5 11,9 72,4 190,0 20
49524 16 x 0,14 8,6 32,0 80,0 26 49534 16 x 0,5 12,5 91,6 240,0 20
49525 24 x 0,14 9,0 43,4 110,0 26 49535 24 x 0,5 15,3 130,0 310,0 20
49526 4 x 0,25 6,5 21,3 60,0 24
49527 8 x 0,25 8,0 31,0 90,0 24
49528 12 x 0,25 9,2 40,5 120,0 24
49529 16 x 0,25 9,6 50,1 140,0 24
49530 24 x 0,25 12,0 69,3 200,0 24

Dimensions and specifications may be changed without prior notice. (RB01)

142
Data and Computer Cables

LiY-TPC-Y pairs screened, EMC-preferred type, meter marking

Technical data Cable structure Properties


Pair screened special PVC data Bare copper-conductor, from 0,5 mm to Extensively oil resistant, oil-/ chemical
transmissionn cable adapted DIN VDE 0295 cl.5, fine-wire, Resistance - see table Technical
to DIN VDE 0812 and 0814 BS 6360 cl.5, IEC 60228 cl.5 Informations
Temperature range 0,25 mm2 and 0,34 mm to DIN VDE 0812 The materials used in manufacture are
flexing -5C to +70C Conductor construction: cadmium-free and contain no silicone
fixed installation -30C to +70C 0,25 mm = 14x0,15 mm and free from substances harmful to
Operating peak voltage 500 V 0,34 mm = 7x0,25 mm the wetting properties of lacquers
(not for heavy current installation purposes) Core insulation of special PVC Tests
Test voltage 1200 V compound type TI2 to PVC self-extinguishing and flame retardant
Breakdown voltage min. 2400 V DIN VDE 0207-363-3 / DIN EN 50363-3 acc. to DIN VDE 0482-332-1-2,
Insulation resistance Core identification (pair) to DIN 47100 DIN EN 60332-1-2/IEC 60332-1 (equivalent
min. 20 MOhm x km Cores stranded in pairs with DIN VDE 0472 part 804 test method B)
Radiation resistance optimal lay-length
up to 80x106 cJ/kg (up to 80 Mrad) Each pair with foil wrapping Note
Coupling resistance Pairs individually screened, tinned copper AWG sizes are approximate equivalent
max. 250 Ohm/km coverage approx. 85% values. The actual cross-section is in mm.
Minimum bending radius All pairs-C stranded in layers with optimal
flexing 12x cable lay-length
fixed installation 7,5x cable Foil wrapping
Outer sheath of special PVC
compound type TM2 to
DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Sheath colour grey (RAL 7032)
with meter marking

Application
This pair screened table type offers total interference-free data transfer and is ideal for use as a signal and control cable in combination with computers
and external units. The screening properties also make this cable type well suited for use as a connecting cable in sound studio equipment, measuring
and control sectors as well as proving a highly reliable cable for process-control and security systems. The copper screening assures a disturbance-free
data and signal transmission for measuring and control systems.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21323 2 x 2 x 0,25 6,2 32,0 60,0 24 21355 2 x 2 x 0,5 8,3 58,0 96,0 20
21324 3 x 2 x 0,25 6,8 48,0 80,0 24 21356 3 x 2 x 0,5 9,2 87,0 136,0 20
21325 4 x 2 x 0,25 7,4 64,0 112,0 24 21357 4 x 2 x 0,5 10,2 116,0 187,0 20
21326 5 x 2 x 0,25 8,7 80,0 142,0 24 21370 2 x 2 x 0,75 9,2 76,0 132,0 19
21327 6 x 2 x 0,25 9,1 96,0 159,0 24 21371 3 x 2 x 0,75 10,1 114,0 178,0 19
21328 7 x 2 x 0,25 9,6 112,0 177,0 24 21372 4 x 2 x 0,75 11,2 152,0 243,0 19
21329 10 x 2 x 0,25 11,7 160,0 250,0 24 21373 5 x 2 x 0,75 12,7 190,0 312,0 19
21340 2 x 2 x 0,34 6,7 42,0 78,0 22 21385 2x2x1 9,6 86,0 142,0 18
21341 3 x 2 x 0,34 7,5 63,0 104,0 22 21386 3x2x1 10,8 130,0 189,0 18
21342 4 x 2 x 0,34 8,1 84,0 153,0 22 21387 4x2x1 11,9 149,0 275,0 18
21343 5 x 2 x 0,34 9,5 105,0 189,0 22
21344 7 x 2 x 0,34 10,1 147,0 238,0 22
21345 10 x 2 x 0,34 13,4 210,0 322,0 22

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Cable tie

143
Data and Computer Cables

DATAPUR-C EMC-preferred type, Cu-screened, PUR-outer sheath, meter marking

Technical data Cable structure Properties


Special -PVC/PUR control cable Bare copper-conductor, from 0,5 mm to Chemical resistance: good against acids,
adapted to DIN VDE 0285-525-1 / DIN VDE 0295 cl.5, fine-wire, lyes, hydraulic liquids
DIN EN 50525-1 BS 6360 cl.5, IEC 60228 cl.5 High flexibility at low temperature
Temperature range Conductor construction: High abrasion resistance
flexing -5C to +80C 0,34 mm = 7 x 0,25 mm Resistant to
fixed installation -40C to +80C Core insulation of special PVC Oils and fats
Operating peak voltage compound type TI2 to Non-alcoholic fuels and kerosene
(not for heavy current installation purposes) DIN VDE 0207-363-3 / DIN EN 50363-3 Atmospheric influences
0,14 mm 350 V Core identification to DIN 471000 UV-radiation
as of 0,25 mm 500 V Cores stranded in layers with Oxygene and ozone
Test voltage optimal lay-length Microbes and rotting
0,14 mm 800 V Foil wrapping Sea and waste water
as of 0,25 mm 1200 V Tinned copper braided screen, Vibrations
Insulation resistance approx. 85% coverage The materials used in manufacture are
min. 20 MOhm x km Outer sheath of PUR cadmium-free and contain no silicone
Mutual capacitance core/core: compound type TMPU to and free from substances harmful to
up to 0,34 mm approx. 120 nF/km DIN VDE 0207-363-10-2/ the wetting properties of lacquers
as of 0,5 mm approx. 160 nF/km DIN EN 50363-10-2
Minimum bending radius Sheath colour grey (RAL 7032) Note
flexing 10x cable with meter marking AWG sizes are approximate equivalent
fixed installation 5x cable values. The actual cross-section is in mm.
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Coupling resistance
max. 250 Ohm/km

Application
The specific construction of DATAPUR-C makes this cable type ideal for use in all types of computer systems, office machinery, signal and control
units. DATAPUR-C proves its efficiency but also in the acoustic field in telecommunications, paging and intercom systems but also in the cradle of
technology and in the measuring and control technology.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52490 2 x 0,14 3,9 12,3 21,0 26 52512 2 x 0,34 4,9 17,0 33,0 22
52491 3 x 0,14 4,0 14,0 25,0 26 52513 3 x 0,34 5,1 20,7 42,0 22
52492 4 x 0,14 4,3 15,7 29,0 26 52514 4 x 0,34 5,5 24,7 48,0 22
52493 5 x 0,14 4,7 19,5 35,0 26 52515 5 x 0,34 6,0 30,1 57,0 22
52494 7 x 0,14 5,2 23,4 41,0 26 52516 7 x 0,34 6,6 38,2 77,0 22
52495 10 x 0,14 6,5 28,5 54,0 26 52517 10 x 0,34 8,4 63,1 111,0 22
52496 12 x 0,14 6,7 34,3 64,0 26 52518 12 x 0,34 8,6 74,2 128,0 22
52497 14 x 0,14 6,9 39,9 74,0 26 52519 14 x 0,34 9,0 85,3 144,0 22
52498 18 x 0,14 7,6 51,5 93,0 26 52520 18 x 0,34 10,1 107,4 175,0 22
52499 21 x 0,14 8,4 60,1 108,0 26 52521 21 x 0,34 10,9 124,1 200,0 22
52500 25 x 0,14 9,1 71,9 128,0 26 52522 25 x 0,34 12,0 147,0 233,0 22
52501 2 x 0,25 4,3 14,7 26,0 24 52523 2 x 0,5 5,3 23,2 38,0 20
52502 3 x 0,25 4,5 17,1 33,0 24 52524 3 x 0,5 5,6 30,1 51,0 20
52503 4 x 0,25 4,8 20,6 38,0 24 52525 4 x 0,5 6,4 35,4 58,0 20
52504 5 x 0,25 5,4 24,8 44,0 24 52526 5 x 0,5 6,9 52,6 77,0 20
52505 7 x 0,25 5,8 31,1 53,0 24 52527 7 x 0,5 7,3 65,3 93,0 20
52506 10 x 0,25 7,3 42,0 79,0 24 52528 10 x 0,5 9,6 88,8 134,0 20
52507 12 x 0,25 7,5 51,0 92,0 24 52529 12 x 0,5 9,7 101,9 155,0 20
52508 14 x 0,25 8,1 60,1 105,0 24 52530 14 x 0,5 10,2 115,1 175,0 20
52509 18 x 0,25 9,1 77,9 128,0 24 52531 18 x 0,5 11,5 141,2 214,0 20
52510 21 x 0,25 9,6 91,4 148,0 24 52532 21 x 0,5 12,1 161,1 245,0 20
52511 25 x 0,25 10,6 110,8 175,0 24 52533 25 x 0,5 13,7 187,9 285,0 20

Dimensions and specifications may be changed without prior notice. (RB01)

144
Data and Computer Cables

DATAFLAMM-C EMC-preferred type, halogen-free, screened, meter marking

Technical data Cable structure Properties


Special data cable, halogen-free Bare copper-conductor, to PE-insulated cores, compared with
Temperature range DIN VDE 0812, fine-wire PVC-insulated cores, assure a remarkable
flexing +5C to +70C Conductor construction: and more favourable capacitance values
fixed installation -40C to +70C 0,34 mm = 7x0,25 mm Tests
Operating peak voltage Core insulation of PE Halogen-free to DIN VDE 0482
(not for heavy current installation purposes) compound type L/MD to part 267, DIN EN 50267-2-1, IEC 60754-1
0,14 mm = 350 V DIN VDE 0819-103 / DIN EN 50290-2-23 (equivalent DIN VDE 0472 part 815)
0,25 mm = 500 V Core identification to DIN 47100 Corrosiveness of combustion gases
Test voltage Cores twisted in layers with acc. to DIN VDE 0482 part 267,
0,14 mm = 800 V optimal lay-length DIN EN 50267-2-2, IEC 60754-2
0,25 mm = 1200 V Foil wrapping (equivalent DIN VDE 0472 part 813)
Insulation resistance Tinned copper braided screen, Halogen-free sheath compound,
min. 2 GOhm x km approx. 85% coverage self-extinguishing and flame retardant
Capacitance Outer sheath acc. to DIN VDE 0482-332-1-2,
core/core <70 nF/km compound type HM2 DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius to DIN VDE 0207 part 24 DIN VDE 0472 part 804 test method B)
7,5x cable Sheath colour grey (RAL 7005)
Coupling resistance with meter marking Note
max. 250 Ohm/km AWG sizes are approximate equivalent
Radiation resistance values. The actual cross-section is in mm.
up to 100x106 cJ/kg (up to 100 Mrad) unscreened analogue type:
DATAFLAMM, confer page 130

Application
As a connecting and interconnecting cable for signaling, measuring, control and intercom purposes for the use in paging and intercom systems, clock
systems, weighing equipment and office machines. The cables can be laid on or under plaster, in dry, damp and wet rooms as well as masonry and
concrete. Areas of use are telecommunications and information processing systems in public buildings, laboratories, warehouses and other buildings
in which the release of halogens in the event of fire must be avoided. Due to the shielding without interference against foreign encoder or high-frequency
signals.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52365 2 x 0,14 3,7 12,4 21,0 26 52398 4 x 0,34 5,5 24,5 47,0 22
52366 3 x 0,14 3,9 14,0 25,0 26 52399 5 x 0,34 6,0 30,0 58,0 22
52367 4 x 0,14 4,1 15,8 26,0 26 52400 7 x 0,34 6,4 38,2 76,0 22
52368 5 x 0,14 4,4 19,5 32,0 26 52401 10 x 0,34 8,0 62,2 110,0 22
52369 7 x 0,14 4,7 23,4 39,0 26 52402 12 x 0,34 8,5 69,4 123,0 22
52370 10 x 0,14 5,9 28,4 54,0 26 52403 14 x 0,34 9,0 82,1 140,0 22
52371 12 x 0,14 6,0 31,4 69,0 26 52404 16 x 0,34 9,5 95,0 157,0 22
52372 14 x 0,14 6,4 37,5 76,0 26 52405 18 x 0,34 10,2 107,3 172,0 22
52373 16 x 0,14 6,7 43,4 82,0 26 52406 21 x 0,34 10,8 122,4 195,0 22
52374 18 x 0,14 7,0 51,4 90,0 26 52407 25 x 0,34 12,2 142,2 226,0 22
52375 21 x 0,14 7,4 61,8 102,0 26 52408 30 x 0,34 12,7 162,6 261,0 22
52376 25 x 0,14 8,3 76,0 121,0 26 52409 34 x 0,34 13,7 178,9 285,0 22
52377 30 x 0,14 8,6 92,7 146,0 26 52410 40 x 0,34 14,9 203,3 330,0 22
52378 34 x 0,14 9,4 121,0 167,0 26 52411 2 x 0,5 5,1 23,0 37,0 20
52379 40 x 0,14 10,2 126,1 170,0 26 52412 3 x 0,5 5,5 30,0 46,0 20
52380 2 x 0,25 4,3 14,6 23,0 24 52413 4 x 0,5 5,9 35,3 57,0 20
52381 3 x 0,25 4,5 17,0 28,0 24 52414 5 x 0,5 6,6 52,5 77,0 20
52382 4 x 0,25 4,8 20,6 34,0 24 52415 7 x 0,5 7,1 65,3 92,0 20
52384 5 x 0,25 5,2 24,7 42,0 24 52416 10 x 0,5 9,3 88,7 135,0 20
52385 7 x 0,25 5,6 31,2 49,0 24 52417 12 x 0,5 9,4 98,7 148,0 20
52386 10 x 0,25 7,2 42,1 81,0 24 52418 18 x 0,5 11,1 141,2 210,0 20
52387 12 x 0,25 7,3 47,5 88,0 24 52419 21 x 0,5 12,0 161,0 242,0 20
52388 14 x 0,25 7,9 52,7 100,0 24 52420 25 x 0,5 13,5 187,2 285,0 20
52389 16 x 0,25 8,3 58,1 113,0 24 52421 30 x 0,5 14,2 223,2 340,0 20
52390 18 x 0,25 9,1 78,0 126,0 24 52422 40 x 0,5 16,5 294,9 445,0 20
52391 21 x 0,25 9,5 94,3 144,0 24 52423 2 x 0,75 5,9 30,6 45,0 19
52392 25 x 0,25 10,6 116,5 164,0 24 52424 3 x 0,75 6,2 38,1 60,0 19
52393 30 x 0,25 11,1 132,2 191,0 24 52425 4 x 0,75 6,9 58,0 80,0 19
52394 34 x 0,25 11,9 144,6 214,0 24 52426 5 x 0,75 7,5 68,4 97,0 19
52395 40 x 0,25 13,0 163,3 245,0 24 52427 7 x 0,75 8,1 88,4 127,0 19
52396 2 x 0,34 4,8 16,9 31,0 22 52428 10 x 0,75 10,4 122,5 175,0 19
52397 3 x 0,34 5,1 20,6 38,0 22 52429 12 x 0,75 10,9 137,2 196,0 19

Dimensions and specifications may be changed without prior notice. (RB01)

145
Data and Computer Cables

DATAFLAMM-C-PAAR EMC-preferred type, halogen-free, screened,


meter marking

Technical data Cable structure Properties


Special data cable, halogen-free Bare copper-conductor, fine-wire Tests
Temperature range to DIN VDE 0812 Halogen-free to DIN VDE 0482
flexing +5C to +70C Conductor construction: part 267, DIN EN 50267-2-1, IEC 60754-1
fixed installation -40C to +70C 0,34 mm = 7x0,25 mm (equivalent DIN VDE 0472 part 815)
Operating peak voltage Core insulation of PE Corrosiveness of combustion gases
(not for heavy current installation purposes) compound type L/MD to acc. to DIN VDE 0482 part 267,
0,14 mm = 350 V DIN VDE 0819-103 / DIN EN 50290-2-23 DIN EN 50267-2-2, IEC 60754-2
0,25 mm = 500 V Core identification to DIN 47100 (equivalent DIN VDE 0472 part 813)
Test voltage Cores stranded in pairs with Halogen-free sheath compound,
0,14 mm = 800 V optimal lay-length self-extinguishing and flame retardant
0,25 mm = 1200 V Pairs stranded in layers with acc. to DIN VDE 0482-332-1-2,
Insulation resistance optimal lay-length DIN EN 60332-1-2, IEC 60332-1 (equivalent
min. 2 GOhm x km Foil wrapping DIN VDE 0472 part 804 test method B)
Capacitance Tinned copper braided screen,
core/core < 70 nF/km approx. 85% coverage Note
Minimum bending radius Outer sheath AWG sizes are approximate equivalent
7,5x cable compound type HM2 to values. The actual cross-section is in mm.
Coupling resistance DIN VDE 0207 part 24
max. 250 Ohm/km Sheath colour grey (RAL 7005)
Radiation resistance with meter marking
up to 100x106 cJ/kg (up to 100 Mrad)

Application
Are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic
weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments as
well as in masonry and concrete. PE-insulated cores, compared with the conventional PVC-insulated cores, assure a remarkable and more favourable
capacitance values. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories,
trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. With screened braiding offers
interference-free signal transfer. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52435 2 x 2 x 0,14 4,7 22,5 37,0 26 52460 7 x 2 x 0,34 9,8 89,8 154,0 22
52436 3 x 2 x 0,14 5,1 25,6 47,0 26 52461 10 x 2 x 0,34 12,2 119,8 209,0 22
52437 4 x 2 x 0,14 5,8 39,1 66,0 26 52462 12 x 2 x 0,34 12,9 139,4 245,0 22
52438 5 x 2 x 0,14 6,3 45,3 76,0 26 52463 15 x 2 x 0,34 14,4 160,0 279,0 22
52439 6 x 2 x 0,14 6,8 51,4 87,0 26 52464 18 x 2 x 0,34 15,3 207,2 363,0 22
52440 7 x 2 x 0,14 6,8 54,2 94,0 26 52465 2 x 2 x 0,5 7,4 50,2 76,0 20
52441 10 x 2 x 0,14 8,9 68,7 119,0 26 52466 3 x 2 x 0,5 8,0 64,5 107,0 20
52442 12 x 2 x 0,14 9,2 78,3 135,0 26 52467 4 x 2 x 0,5 9,0 77,2 134,0 20
52443 15 x 2 x 0,14 10,0 79,9 157,0 26 52468 5 x 2 x 0,5 9,9 96,2 150,0 20
52444 18 x 2 x 0,14 11,0 99,2 190,0 26 52469 6 x 2 x 0,5 10,9 107,4 176,0 20
52445 2 x 2 x 0,25 5,7 27,1 44,0 24 52470 7 x 2 x 0,5 10,9 117,3 185,0 20
52446 3 x 2 x 0,25 6,2 42,4 66,0 24 52471 10 x 2 x 0,5 13,8 158,2 275,0 20
52447 4 x 2 x 0,25 7,0 54,5 81,0 24 52472 12 x 2 x 0,5 14,5 177,8 330,0 20
52448 5 x 2 x 0,25 7,9 59,8 98,0 24 52473 15 x 2 x 0,5 15,8 236,4 380,0 20
52449 6 x 2 x 0,25 8,6 64,6 116,0 24 52474 18 x 2 x 0,5 17,1 265,4 450,0 20
52450 7 x 2 x 0,25 8,6 71,3 120,0 24 52475 2 x 2 x 0,75 8,5 64,6 105,0 19
52451 10 x 2 x 0,25 10,6 93,3 153,0 24 52476 3 x 2 x 0,75 9,3 81,7 137,0 19
52452 12 x 2 x 0,25 11,4 108,0 175,0 24 52477 4 x 2 x 0,75 10,6 107,6 166,0 19
52453 15 x 2 x 0,25 12,5 123,4 213,0 24 52478 5 x 2 x 0,75 11,7 126,1 200,0 19
52454 18 x 2 x 0,25 13,1 139,7 248,0 24 52479 6 x 2 x 0,75 12,7 138,6 236,0 19
52455 2 x 2 x 0,34 6,5 43,3 68,0 22 52480 7 x 2 x 0,75 12,7 153,7 255,0 19
52456 3 x 2 x 0,34 7,2 55,0 92,0 22 52481 10 x 2 x 0,75 15,6 220,0 363,0 19
52457 4 x 2 x 0,34 7,9 64,0 110,0 22 52482 12 x 2 x 0,75 16,8 265,5 434,0 19
52458 5 x 2 x 0,34 8,8 74,5 128,0 22 52483 15 x 2 x 0,75 18,6 327,6 500,0 19
52459 6 x 2 x 0,34 9,8 85,0 147,0 22 52484 18 x 2 x 0,75 20,5 374,6 580,0 19

Dimensions and specifications may be changed without prior notice. (RB01)

146
Data and Computer Cables

EDV-PiMF-CY PE-insulated, low capacitance, EMC-preferred type, meter marking

Technical data Cable structure Properties


PE data cable Bare copper-conductor, to The materials used in manufacture are
Temperature range DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
flexing -5C to +80C BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
fixed installation -20C to +80C Core insulation of PE the wetting properties of lacquers
Operating peak voltage max. 300 V Core identification to DIN 47100 Tests
(not for heavy current installation purposes) PiMF: (pair in metal foil) cores twisted in PVC outer sheath self-extinguishing and
Test voltage pairs; foil wrapped, plastic coated flame retardant acc. to DIN VDE
core/core 2000 V aluminium foil and copper drain-wire tinned, 0482-332-1-2,
core/screen 1000 V 100% coverage DIN EN 60332-1-2, IEC 60332-1 (equivalent
Insulation resistance PiMFs are stranded in layer DIN VDE 0472 part 804 test method B)
approx. 5 GOhm x km Foil wrapping
Mutual capacitance (approx. value) Overall copper screened braiding, Note
core/core approx. 75pF/m 85% coverage AWG sizes are approximate equivalent
Inductance approx. 0,4 mH/km Outer sheath of PVC values. The actual cross-section is in mm.
Cross-talk attenuation compound type TM2 adapted to
min. 60 dB at 100 kHz DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Impedance (approx. value) Sheath colour grey (RAL 7032)
at 1 kHz approx. 360 Ohm with meter marking
at 10 kHz approx. 125 Ohm
at 100 kHz approx. 87 Ohm
at 1000 kHz approx. 70 Ohm
Line attenuation (approx. value)
at 1 kHz approx. 1,1 dB
at 10 kHz approx. 2,7 dB
at 100 kHz approx. 6,8 dB
at 1000 kHz approx. 35 dB
Minimum bending radius
flexing 10x cable
fixed installation 5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Coupling resistance
max. 250 Ohm/km

Application
Absolute disturbance-free data transfer both for installed terminals in all areas of medicine and data technology. Also suitable for use in machine tool
and steel producing industries, traffic signal systems, assembly lines and food processing.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
43553 2 x 2 x 0,5 8,7 50,0 101,0 20 43539 30 x 2 x 0,75 30,3 765,0 1210,0 19
43554 3 x 2 x 0,5 9,8 66,0 120,0 20 43559 2x2x1 12,3 72,0 130,0 18
43524 4 x 2 x 0,5 10,8 108,0 196,0 20 43560 3x2x1 13,4 104,0 161,0 18
43555 5 x 2 x 0,5 12,0 120,0 201,0 20 43540 4x2x1 14,8 186,0 360,0 18
43525 6 x 2 x 0,5 13,1 148,0 260,0 20 43561 5x2x1 16,6 231,0 412,0 18
43526 8 x 2 x 0,5 14,4 180,0 310,0 20 43541 6x2x1 18,4 260,0 472,0 18
43527 10 x 2 x 0,5 17,3 236,0 398,0 20 43542 8x2x1 20,1 322,0 540,0 18
43528 16 x 2 x 0,5 20,2 338,0 515,0 20 43543 10 x 2 x 1 23,9 382,0 670,0 18
43529 20 x 2 x 0,5 21,6 394,0 688,0 20 43544 16 x 2 x 1 27,8 578,0 982,0 18
43530 30 x 2 x 0,5 27,3 577,0 980,0 20 43545 20 x 2 x 1 30,3 710,0 1240,0 18
43531 40 x 2 x 0,5 28,9 684,0 1390,0 20 43546 30 x 2 x 1 36,0 1050,0 1720,0 18
43532 50 x 2 x 0,5 31,4 834,0 1860,0 20 43562 2 x 2 x 1,5 13,4 81,0 164,0 16
43556 2 x 2 x 0,75 10,1 61,0 117,0 19 43563 3 x 2 x 1,5 14,9 141,0 197,0 16
43557 3 x 2 x 0,75 11,3 97,0 142,0 19 43547 4 x 2 x 1,5 16,6 261,0 480,0 16
43533 4 x 2 x 0,75 12,2 141,0 240,0 19 43564 5 x 2 x 1,5 18,4 284,0 516,0 16
43558 5 x 2 x 0,75 13,6 163,0 304,0 19 43548 6 x 2 x 1,5 20,4 355,0 590,0 16
43534 6 x 2 x 0,75 15,1 198,0 352,0 19 43549 8 x 2 x 1,5 22,4 448,0 696,0 16
43535 8 x 2 x 0,75 16,6 246,0 415,0 19 43550 10 x 2 x 1,5 27,0 551,0 874,0 16
43536 10 x 2 x 0,75 19,7 305,0 505,0 19 43551 16 x 2 x 1,5 31,0 838,0 1340,0 16
43537 16 x 2 x 0,75 23,0 446,0 732,0 19 43552 20 x 2 x 1,5 32,1 1030,0 1620,0 16
43538 20 x 2 x 0,75 24,7 530,0 860,0 19

Dimensions and specifications may be changed without prior notice. (RB01)

147
Data and Computer Cables

RD-Y(St)Y Instrumentation Cable suitable for Maxi-Termi-Point-connection,


meter marking

Technical data Cable structure Properties


Special -PVC data transmission cable Bare copper-conductor, multi-wire Twisted pairs with short different
adapted to DIN VDE 0815 Conductor construction: lay-lengths within a bundle results
Conductor resistance (loop) 0,5 mm = 7x0,3 mm to good crosstalk attentuation values
max. 73,6 Ohm/km Core insualtion of PVC (Semi-Rigid-PVC) The static screen protects the
Temperature range Core identification coloured transmission circuits against outer
flexing -5C to +50C pair-no.1: a-core = BU; b-core = RD electrical interferences
fixed installation -40C to +70C pair-no.2: a-core = GY; b-core = YE The materials used in manufacture are
Operating peak voltage max. 600 V pair-no.3: a-core = GN; b-core = BN cadmium-free and contain no silicone
(not for heavy current installation purposes) pair-no.4: a-core = WH; b-core = BK and free from substances harmful to
Test voltage Cores stranded in pairs the wetting properties of lacquers
core/core 2000 V (approx. 20 pitch/m 50 mm) Tests
core/screen 2000 V 4 pairs stranded to a unit PVC self-extinguishing and flame retardant
Insulation resistance (unit labelled with numbers acc. to DIN VDE 0482-332-1-2,
core/core min. 100 MOhm x km printed plastic helix) DIN EN 60332-1-2, IEC 60332-1 (equivalent
core/screen min. 100 MOhm x km Units stranded in concentric layers DIN VDE 0472 part 804 test method B)
Mutual capacitance Electrostatic screen of plastic coated
at 800 Hz max. 100 nF/km aluminium foil and drain-wire tinned, Note
(this value may be exceeded 0,5 mm = 7x0,3 mm Cop.weight including drain-wire.
by 20% with a make-up to 4 pairs) Outer sheath of PVC Also available halogen-free type
Impedance Sheath colour grey (RAL 7032) RD-H(St)H on request.
at 1 kHz approx. 370 Ohm or blue (RAL 5015) Maxi-Termi-Point = registered trade

at 10 kHz approx. 130 Ohm with meter marking mark AMP.


Capacity unbalance AWG sizes are approximate equivalent
at 800 Hz max. 200 pF/100 m values. The actual cross-section is in mm.
(20% of the values, but one
value up to 400 pF is allowed)
Line attenuation
at 1 kHz approx. 1,2 dB/km
at 10 kHz approx. 3,0 dB/km
Cross-talk attenuation at 10 kHz
and cable length of 500 m min. 60 dB
Minimum bending radius
7,5x cable

Application
The data transmission cables RD-Y(St)Y are used in measurement and control technology such as in control rooms of industrial plants and power
stations. The cables serves for transmission of analog and digital signals up to frequencies of approx. 10 kHz. These cables offer considerable advantages
by using the quick and economical connecting possibilities in Maxi-Termi-Point technique. This solderless connecting technique is defined by a
compression termination that employs a spring-clip for the connection of the cable to a square rigid post without pre-stripping. For this technique it
is necessary to have an exact 7-core stranded conductor and a Semi-Rigid-PVC. Suitable for fixed installation only inside of buildings. With blue outer
sheath suitable for intrinsic safe systems.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part No.pairs x Sheath No. Outer Cop. Weight AWG-No. Part No.pairs x Sheath No. Outer Cop. Weight AWG-No.
no. cross-sec. colour units approx. weight approx. no. cross-sec. colour units approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
20140 2 x 2 x 0,5 GY - 6,8 25,0 61,0 20 20189 2 x 2 x 0,5 BU - 6,8 25,0 61,0 20
20141 4 x 2 x 0,5 GY 1 8,7 45,0 96,0 20 20190 4 x 2 x 0,5 BU 1 8,7 45,0 96,0 20
20142 8 x 2 x 0,5 GY 2 11,0 85,0 160,0 20 20191 8 x 2 x 0,5 BU 2 11,0 85,0 160,0 20
20143 12 x 2 x 0,5 GY 3 12,5 125,0 210,0 20 20192 12 x 2 x 0,5 BU 3 12,5 125,0 210,0 20
20144 16 x 2 x 0,5 GY 4 14,0 165,0 282,0 20 20193 16 x 2 x 0,5 BU 4 14,0 165,0 282,0 20
20145 24 x 2 x 0,5 GY 6 17,0 245,0 330,0 20 20194 24 x 2 x 0,5 BU 6 17,0 245,0 330,0 20
20146 32 x 2 x 0,5 GY 8 20,0 325,0 530,0 20 20195 32 x 2 x 0,5 BU 8 20,0 325,0 530,0 20
20147 48 x 2 x 0,5 GY 12 23,5 485,0 730,0 20 20196 48 x 2 x 0,5 BU 12 23,5 485,0 730,0 20
20148 96 x 2 x 0,5 GY 24 32,5 965,0 1400,0 20 20197 96 x 2 x 0,5 BU 24 32,5 965,0 1400,0 20

Dimensions and specifications may be changed without prior notice. (RB01)

148
Data and Computer Cables

RD-Y(St)Yv / RD-Y(St)YY reinforced (double) outer sheath,


instrumentation cable, Maxi-Termi-Point , meter marking

Technical data Cable structure Properties


Special -PVC data transmission cable Bare copper-conductor, multi-wires The static screen protects the
adapted to DIN VDE 0815 and 0816 Conductor construction: transmission circuits against
Conductor resistance (loop) 0,5 mm = 7x0,3 mm outer electrical interferences
max. 73,6 Ohm/km Core insulation of PVC (Semi-Rigid-PVC) The materials used in manufacture are
Temperature range Cores colour coded cadmium-free and contain no silicone
flexing -5C to +50C pair-no.1: a-core = BU; b-core = RD and free from substances harmful to
fixed installation -40C to +70C pair-no.2: a-core = GY; b-core = YE the wetting properties of lacquers
Operating peak voltage max. 600 V pair-no.3: a-core = GN; b-core = BN Tests
(not for heavy current installation purposes) pair-no.4: a-core = WH; b-core = BK PVC self-extinguishing and flame retardant
Test voltage Cores twisted in pairs acc. to DIN VDE 0482-332-1-2,
core/core 2000 V (approx. 20 pitch/m 50 mm) DIN EN 60332-1-2, IEC 60332-1 (equivalent
core/screen 2000 V 4 pairs stranded to a unit DIN VDE 0472 part 804 test method B)
Insulation resistance (unit labelled with numbers
core/core min. 100 MOhm x km printed plastic helix) Note
core/screen min. 100 MOhm x km units stranded in concentric layers Cop.Weight including drain-wire.
Mutual capacitance Static screen (St) of plastic coated metal Maxi-Termi-Point = registered trade
at 800 Hz max. 100 nF/km foil with stranded tinned drain wire, mark AMP.
(this value may be exceeded 0,5 mm = 7x0,3 mm AWG sizes are approximate equivalent
by 20% with a make-up to 4 pairs) Outer sheath of PVC values. The actual cross-section is in mm.
Impedance Sheath colour grey (RAL 7032)
at 1 kHz approx. 370 Ohm with meter marking
at 10 kHz approx. 130 Ohm
Capacity unbalance
at 800 Hz max. 200 pF/100 m
(20% of the values, but one
value up to 400 pF is allowed)
Line attenuation
at 1 kHz approx. 1,2 dB/km
at 10 kHz approx. 3,0 dB/km
Cross-talk attenuation
at 10 kHz and cable length of 500 m
min. 60 dB
Minimum bending radius
7,5x cable

Application
The data transmission cables RD-Y(St)Yv are used in measurement and control technology such as in control rooms of industrial plants and power
stations. The pairs are twisted with short pitches and different lay-lengths which lead to good crosstalk attenuation values in a unit. The cables serves
for transmission of analog and digital signals up to frequencies of approx. 10 kHz. These cables offer considerable advantages by using the quick and
economical connecting possibilities in Maxi-Termi-Point technique. This solderless connecting technique is defined by a compression termination
that employs a spring-clip for the connection of the cable to a square rigid post without pre-stripping. For this technique it is necessary to have an
exact 7-core stranded conductor and a Semi-Rigid-PVC. Suitable for fixed installation only inside of buildings. With the reinforced PVC(-Yv) outer
sheath these cables are suitable for fixed installation in inside buildings and also in open air and in underground.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
RD-Y(St)Yv RD-Y(St)YY
Part no. No.pairs x No. Outer Cop. Weight AWG-No. Part no. No.pairs x No. Outer Cop. Weight AWG-No.
cross-sec. units approx. weight approx. cross-sec. units approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
20160 2 x 2 x 0,5 - 8,5 25,0 80,0 20 20180 2 x 2 x 0,5 - 8,5 25,0 90,0 20
20161 4 x 2 x 0,5 1 10,0 45,0 125,0 20 20181 4 x 2 x 0,5 1 10,6 45,0 140,0 20
20162 8 x 2 x 0,5 2 13,0 85,0 200,0 20 20182 8 x 2 x 0,5 2 13,2 85,0 220,0 20
20163 12 x 2 x 0,5 3 14,0 125,0 255,0 20 20183 12 x 2 x 0,5 3 14,8 125,0 275,0 20
20164 16 x 2 x 0,5 4 15,5 165,0 315,0 20 20184 16 x 2 x 0,5 4 15,8 165,0 350,0 20
20165 24 x 2 x 0,5 6 18,5 245,0 370,0 20 20185 24 x 2 x 0,5 6 18,2 245,0 470,0 20
20166 32 x 2 x 0,5 8 20,5 325,0 555,0 20 20186 32 x 2 x 0,5 8 22,8 325,0 620,0 20
20167 48 x 2 x 0,5 12 24,0 485,0 1045,0 20 20187 48 x 2 x 0,5 12 24,0 485,0 850,0 20
20168 96 x 2 x 0,5 24 35,5 965,0 1300,0 20 20188 96 x 2 x 0,5 24 36,5 965,0 1450,0 20

Dimensions and specifications may be changed without prior notice. (RB01)

149
Data and Computer Cables

RE-2Y(St)Yv instrumentation cable, reinforced outer sheath, meter marking

Technical data Cable structure Properties


Special core insulation of PE Bare copper-conductor, multi-wires The electrostatic screen protect the
Conductor resistance Conductor construction: screened pairs against outer electrostatic
0,5 mm: max. 39,2 Ohm/km 0,5 mm = 7x0,3 mm interference fields
0,75 mm: max. 24,6 Ohm/km 0,75 mm = 7x0,37 mm Low level of line attenuations and low
1,3 mm: max. 14,2 Ohm/km 1,3 mm = 7x0,49 mm mutual capacitances enable long
Temperature range Core insulation of PE transmission distances and fast pulse
flexing -5C to +50C Cores coloured acceleration
fixed installation -40C to +70C with number print 1/1, 2/2 etc. The materials used in manufacture are
Operating peak voltage max. 300 V pair: a-core = BK; b-core = WH cadmium-free and contain no silicone
(not for heavy current installation purposes) triple: a-core = BK; b-core = WH; and free from substances harmful to
Test voltage c-core = RD the wetting properties of lacquers
core/core 2000 V Cores twisted to pairs with optimum pitch Tests
core/screen 1000 V Pairs stranded in layer self-extinguishing and flame retardant
Insulation resistance 1 communication core 0,5 mm, PE-insulated, acc. to DIN VDE 0482-332-1-2,
min. 5 GOhm x km orange (for multicore version) DIN EN 60332-1-2, IEC 60332-1 (equivalent
Mutual capacitance at 800 Hz Foil wrapping DIN VDE 0472 part 804 test method B)
core/core 0,5 mm: 60 nF/km Electrostatic screen (St) of plastics-coated
for 1 and 2 pairs: 75 nF/km metal foil Note
core/core 0,75 mm: 65 nF/km Tinned drain-wire, 0,5 mm = 7x0,3 mm Cop.Weight including communication core
for 1 and 2 pairs: 110 nF/km Outer sheath of PVC, reinforced, and drain-wire.
core/core 1,3 mm: 75 nF/km black (RAL 9005) or blue (RAL 5015) Control cable with blue outer sheath, see
for 1 and 2 pairs: 100 nF/km with meter marking Flexible Control Cables
Inductance max. 0,75 mH/km Wall-thickness to DIN VDE 0816 part 1, with blue outer sheath for hazardous areas
Cross-talk attenuation table 7, col. 1 to hazard type -i- for intrinsically safe
min. 0,88 dB/km at 60 kHz installation acc. to DIN EN 60079-14
Minimum bending radius section 12.2.2 (VDE 0165 part 1)
7,5x cable AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Instrumentation cables are used in data processing and process control. Instrumentation cables are suitable for fixed installations in damp locations,
in open spaces and for underground laying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Sheath Outer Cop. Weight AWG-No. Part no. No.pairs x Sheath Outer Cop. Weight AWG-No.
cross-sec. colour approx. weight approx. cross-sec. colour approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
20099 1 x 2 x 0,5 BK 7,5 15,0 74,0 20 20235 1 x 2 x 0,5 BU 7,5 15,0 74,0 20
20100 2 x 2 x 0,5 BK 9,8 30,0 117,0 20 20236 2 x 2 x 0,5 BU 9,8 30,0 117,0 20
20101 4 x 2 x 0,5 BK 11,3 50,0 140,0 20 20237 4 x 2 x 0,5 BU 11,3 50,0 140,0 20
20233 6 x 2 x 0,5 BK 13,1 70,0 190,0 20 20238 6 x 2 x 0,5 BU 13,1 70,0 190,0 20
20102 8 x 2 x 0,5 BK 14,6 90,0 215,0 20 20239 8 x 2 x 0,5 BU 14,6 90,0 215,0 20
20103 10 x 2 x 0,5 BK 16,1 110,0 220,0 20 20240 10 x 2 x 0,5 BU 16,1 110,0 220,0 20
20104 12 x 2 x 0,5 BK 16,4 130,0 280,0 20 20241 12 x 2 x 0,5 BU 16,4 130,0 280,0 20
20105 16 x 2 x 0,5 BK 18,3 170,0 352,0 20 20242 16 x 2 x 0,5 BU 18,3 170,0 352,0 20
20106 20 x 2 x 0,5 BK 19,2 210,0 385,0 20 20243 20 x 2 x 0,5 BU 19,2 210,0 385,0 20
20107 24 x 2 x 0,5 BK 22,3 250,0 468,0 20 20244 24 x 2 x 0,5 BU 22,3 250,0 468,0 20
20108 36 x 2 x 0,5 BK 24,5 370,0 656,0 20 20245 36 x 2 x 0,5 BU 24,5 370,0 656,0 20
20109 48 x 2 x 0,5 BK 27,7 490,0 854,0 20 20246 48 x 2 x 0,5 BU 27,7 490,0 854,0 20
20149 1 x 2 x 0,75 BK 7,9 20,0 74,0 19 20169 1 x 2 x 0,75 BU 7,9 20,0 74,0 19
20150 2 x 2 x 0,75 BK 10,4 35,0 123,0 19 20170 2 x 2 x 0,75 BU 10,4 35,0 123,0 19
20151 4 x 2 x 0,75 BK 11,9 65,0 164,0 19 20171 4 x 2 x 0,75 BU 11,9 65,0 164,0 19
20152 8 x 2 x 0,75 BK 15,0 125,0 258,0 19 20172 8 x 2 x 0,75 BU 15,0 125,0 258,0 19
20153 10 x 2 x 0,75 BK 17,0 154,0 305,0 19 20173 10 x 2 x 0,75 BU 17,0 154,0 305,0 19
20154 12 x 2 x 0,75 BK 17,6 185,0 350,0 19 20174 12 x 2 x 0,75 BU 17,6 185,0 350,0 19
20155 16 x 2 x 0,75 BK 19,5 245,0 445,0 19 20175 16 x 2 x 0,75 BU 19,5 245,0 445,0 19
20156 20 x 2 x 0,75 BK 21,5 298,0 520,0 19 20176 20 x 2 x 0,75 BU 21,5 298,0 520,0 19
20157 24 x 2 x 0,75 BK 24,0 365,0 620,0 19 20177 24 x 2 x 0,75 BU 24,0 365,0 620,0 19
20158 36 x 2 x 0,75 BK 26,5 532,0 940,0 19 20178 36 x 2 x 0,75 BU 26,5 532,0 940,0 19
20159 48 x 2 x 0,75 BK 30,3 708,0 1250,0 19 20179 48 x 2 x 0,75 BU 30,3 708,0 1250,0 19
20125 1 x 2 x 1,3 BK 8,7 31,0 102,0 - 20247 1 x 2 x 1,3 BU 8,7 31,0 102,0 -
20132 1 x 3 x 1,3 BK 9,0 44,0 116,0 - 20255 1 x 3 x 1,3 BU 9,0 44,0 116,0 -
20126 2 x 2 x 1,3 BK 11,5 62,0 161,0 - 20248 2 x 2 x 1,3 BU 11,5 62,0 161,0 -
20127 4 x 2 x 1,3 BK 14,3 114,0 230,0 - 20249 4 x 2 x 1,3 BU 14,3 114,0 230,0 -
20234 6 x 2 x 1,3 BK 16,0 168,0 310,0 - 20250 6 x 2 x 1,3 BU 15,8 168,0 310,0 -
20128 8 x 2 x 1,3 BK 17,3 218,0 377,0 - 20251 8 x 2 x 1,3 BU 17,3 218,0 377,0 -
20129 12 x 2 x 1,3 BK 20,5 322,0 515,0 - 20252 12 x 2 x 1,3 BU 20,5 322,0 515,0 -
20130 16 x 2 x 1,3 BK 23,0 426,0 656,0 - 20253 16 x 2 x 1,3 BU 23,0 426,0 656,0 -
20131 24 x 2 x 1,3 BK 27,9 684,0 952,0 - 20254 24 x 2 x 1,3 BU 27,9 684,0 952,0 -

Dimensions and specifications may be changed without prior notice. (RB01)

150
Data and Computer Cables

RE-2Y(St)Yv PiMF Instrumentation cable, pairs screened, reinforced outer


sheath, meter marking

Technical data Cable structure Properties


Special core insulation of PE Bare copper stranded wires The materials used in manufacture are
Conductor resistance 0,5 mm 2 =7x0,3 mm cadmium-free and contain no silicone
0,5 mm = max. 39,2 Ohm/km 1,3 mm = 7x0,49 mm and free from substances harmful to
1,3 mm = max. 14,2 Ohm/km Core insulation of PE the wetting properties of lacquers
Temperature range Cores coloured Tests
flexing -5C to +50C with number print 1/1, 2/2 etc. self-extinguishing and flame retardant
fixed installation -40C to +70C a-core = BK; b-core = WH acc. to DIN VDE 0482-332-1-2,
Operating peak voltage max. 300 V Cores twisted in pairs with optimum pitch DIN EN 60332-1-2/IEC 60332-1 (equivalent
(not for heavy current installation purposes) PiMF (pair in metal foil), DIN VDE 0472 part 804 test method B)
Test voltage PiMF structure: foil taping,
core/core 2000 V Cu-tinned drain-wire 0,6 mm , Note
core/screen 1000 V plastic coated alu-foil Cop.weight including communication core
Insulation resistance and foil wrapping and drain-wire.
min. 5 GOhm x km PiMFe stranded in layer, Control cable with blue outer sheath, see
Mutual capacitance (approx. value) 1 communication core 0,5 mm, Flexible Control Cables
at 800 Hz PE-insulated orange (communication core with blue outer sheath for hazardous areas
core/core 0,5 mm = 75 nF/km for multicore version) to hazard type -i- for intrinsically safe
core/core 1,3 mm = 100 nF/km Electrostatic screen (St) of plastics-coated installation acc. to DIN EN 60079-14
Inductance max. 0,75 mH/km metal foil and tinned drain-wire 0,5 mm section 12.2.2 (VDE 0165 part 1)
Cross-talk attenuation (7x0,3 mm) AWG sizes are approximate equivalent
min. 1,02 dB/km at 60 kHz Outer sheath of PVC, reinforced, values. The actual cross-section is in mm.
Minimum bending radius black (RAL 9005) or blue (RAL 5015)
7,5x cable with meter marking
Wall-thickness to DIN VDE 0816 part 1,
table 7, col. 1

Application
Instrumentation cables are used in data processing and process control. The individual screening of the pairs guarantee high cross-talk attenuation.
The electrostatic screen protect the screened pairs against outer electrostatic interference fields. Low level of line attenuations and low mutual
capacitances enable long transmission distances and fast pulse acceleration. Instrumentation cables are suitable for fixed installations in damp locations,
in open spaces and for underground laying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Sheath Outer Cop. Weight AWG-No. Part no. No.pairs x Sheath Outer Cop. Weight AWG-No.
cross-sec. colour approx. weight approx. cross-sec. colour approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
20115 2 x 2 x 0,5 BK 11,0 35,0 128,0 20 21537 2 x 2 x 0,5 BU 11,0 35,0 128,0 20
20116 4 x 2 x 0,5 BK 12,6 60,0 170,0 20 21538 4 x 2 x 0,5 BU 12,6 60,0 170,0 20
21535 6 x 2 x 0,5 BK 14,6 82,0 215,0 20 21539 6 x 2 x 0,5 BU 14,6 82,0 215,0 20
20117 8 x 2 x 0,5 BK 15,5 121,0 246,0 20 21540 8 x 2 x 0,5 BU 15,5 121,0 246,0 20
20118 10 x 2 x 0,5 BK 16,8 136,0 261,0 20 21541 10 x 2 x 0,5 BU 16,8 136,0 261,0 20
20119 12 x 2 x 0,5 BK 17,9 161,0 351,0 20 21542 12 x 2 x 0,5 BU 17,9 161,0 351,0 20
20120 16 x 2 x 0,5 BK 19,8 212,0 430,0 20 21543 16 x 2 x 0,5 BU 19,8 212,0 430,0 20
20121 20 x 2 x 0,5 BK 21,0 262,0 496,0 20 21544 20 x 2 x 0,5 BU 21,0 262,0 496,0 20
20122 24 x 2 x 0,5 BK 23,4 313,0 604,0 20 21545 24 x 2 x 0,5 BU 23,4 313,0 604,0 20
20123 36 x 2 x 0,5 BK 26,5 465,0 850,0 20 21546 36 x 2 x 0,5 BU 26,5 465,0 850,0 20
20124 48 x 2 x 0,5 BK 29,5 616,0 1115,0 20 21547 48 x 2 x 0,5 BU 29,5 616,0 1115,0 20
20133 2 x 2 x 1,3 BK 12,8 68,0 184,0 - 21548 2 x 2 x 1,3 BU 12,8 68,0 184,0 -
20134 4 x 2 x 1,3 BK 14,8 124,0 269,0 - 21549 4 x 2 x 1,3 BU 14,8 124,0 269,0 -
21536 6 x 2 x 1,3 BK 17,3 178,0 370,0 - 21550 6 x 2 x 1,3 BU 17,3 178,0 370,0 -
20135 8 x 2 x 1,3 BK 18,5 239,0 442,0 - 21551 8 x 2 x 1,3 BU 18,5 239,0 442,0 -
20136 12 x 2 x 1,3 BK 21,6 353,0 593,0 - 21552 12 x 2 x 1,3 BU 21,6 353,0 593,0 -
20137 16 x 2 x 1,3 BK 24,7 468,0 789,0 - 21553 16 x 2 x 1,3 BU 24,7 468,0 789,0 -
20138 24 x 2 x 1,3 BK 29,8 697,0 1104,0 - 21554 24 x 2 x 1,3 BU 29,8 697,0 1104,0 -

Dimensions and specifications may be changed without prior notice. (RB01)

151
Data and Computer Cables

JE-Y(St)Y Bd Si industry-elektronic cable according to DIN VDE 0815

Technical data Cable structure Properties


Special industrial electronic cable to Solid bare copper conductor wire 0,8 mm The materials used in manufacture are
DIN VDE 0815 Core insulation of PVC cadmium-free and contain no silicone
Conductor resistance at 20C YI3, to DIN VDE 0207 part 4 and free from substances harmful to
36,6 Ohm/km Core identification (pair) to the wetting properties of lacquers
Temperature range DIN VDE 0815 (Simatic colour code) Tests
flexing -5C to +50C Cores stranded in pairs with PVC self-extinguishing and flame retardant
fixed installation -30C to +70C optimal lay-length acc. to DIN VDE 0482-332-1-2,
Operating peak voltage 225 V 4 pairs stranded to a unit DIN EN 60332-1-2, IEC 60332-1 (equivalent
(not for purposes of high current and Unit stranded with optimal lay-length DIN VDE 0472 part 804 test method B)
power installation) Foil wrapping
Test voltage Shielding of plastic laminated foil Note
core/core 500 V Copper drain-wire Also availabel in a halogen-free version.
core/screen 2000 V Outer sheath of PVC (see also content "Halogen-free Security
Insulation resistance compound type YM1 to Cables and Wires".
min. 100 MOhm x km DIN VDE 0207 part 5 Control cable with blue outer sheath, see
Mutual capacitance Sheath colour grey (RAL 7032) or Flexible Control Cables
max. 100 pF/m (the value can exceed blue (RAL 5015) with blue outer sheath for hazardous areas
of 20% by cables up to 4 pairs) to hazard type -i- for intrinsically safe
Capacitance unbalance installation acc. to DIN EN 60079-14
max. 200 pF/100 m section 12.2.2 (VDE 0165 part 1)
Inductance approx. 0,70 mH/km 2-paired cables:
Attenuation cores stranded to a star quad
at 800 Hz approx. 1,1 dB/km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Minimum bending radius
fixed installation 6x cable
Caloric load values
see table Technical Informations

Application
These cable types are suitable for transmission of signals and measurements in the symmetric circuits of the control and regulation technology, and
for the transmission of data and process information in computer systems. Used in dry and damp premises, and in or under plaster in the open air for
fixed installation. Installation cables are not allowed for purposes of high current and power or burial installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Sheath Outer Cop. Weight Part no. No.pairs x Sheath Outer Cop. Weight
cross-sec. colour approx. weight approx. cross-sec. colour approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
48500 1 x 2 x 0,8 GY 5,0 20,0 43,0 - 48519 1 x 2 x 0,8 BU 5,0 20,0 43,0 -
48501 2 x 2 x 0,8 GY 6,6 25,0 60,0 - 48520 2 x 2 x 0,8 BU 6,6 25,0 60,0 -
48502 4 x 2 x 0,8 GY 8,3 45,0 95,0 - 48521 4 x 2 x 0,8 BU 8,3 45,0 95,0 -
48503 8 x 2 x 0,8 GY 10,5 85,0 157,0 - 48522 8 x 2 x 0,8 BU 10,5 85,0 157,0 -
48504 12 x 2 x 0,8 GY 11,8 126,0 224,0 - 48523 12 x 2 x 0,8 BU 11,8 126,0 224,0 -
48505 16 x 2 x 0,8 GY 13,5 166,0 290,0 - 48524 16 x 2 x 0,8 BU 13,5 166,0 290,0 -
48506 20 x 2 x 0,8 GY 14,7 206,0 350,0 - 48525 20 x 2 x 0,8 BU 14,7 206,0 350,0 -
48507 32 x 2 x 0,8 GY 19,0 327,0 545,0 - 48526 32 x 2 x 0,8 BU 19,0 327,0 545,0 -
48508 40 x 2 x 0,8 GY 20,7 407,0 660,0 - 48527 40 x 2 x 0,8 BU 20,7 407,0 660,0 -
48509 80 x 2 x 0,8 GY 29,5 809,0 1160,0 - 48528 80 x 2 x 0,8 BU 29,5 809,0 1160,0 -

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Tool - Multistrip 10

152
Data and Computer Cables

JE-LiYCY Bd Si industry elektronic cable

Technical data Cable structure Properties


Special industry electronic cable Bare copper strands 7x0,3 mm Suitable for cut clamp technology
adapted to DIN VDE 0815 Core insulation of PVC (Semi-Rigid-PVC) The materials used in manufacture are
Conductor resistance at 20C Core identification (pair) to cadmium-free and contain no silicone
39,2 Ohm/km DIN VDE 0815 (Simatic colour code) and free from substances harmful to
Temperature range Cores stranded in pairs with the wetting properties of lacquers
flexing -5C to +50C optimal lay-length Tests
fixed installation -30C to +70C 4 pairs stranded to a unit PVC self-extinguishing and flame retardant
Operating peak voltage 225 V Unit stranded with optimal lay-length acc. to DIN VDE 0482-332-1-2,
(not for heavy current installation purposes) Foil wrapping DIN EN 60332-1-2, IEC 60332-1 (equivalent
Test voltage Bare or tinned copper wire braided, DIN VDE 0472 part 804 test method B)
core/core 500 V 0,2 mm screening,
core/screen 2000 V approx. 85% coverage Note
Insulation resistance Outer sheath of PVC Also availabel in a halogen-free version.
min. 100 MOhm x km compound type YM1 to (see also content "Halogen-free Security
Mutual capacitance max. 100 pF/m DIN VDE 0207 part 5 Cables and Wires")
(the value can exceed of 20% Sheath colour grey (RAL 7032) or Control cable with blue outer sheath, see
by cables up to 4 pairs) blue (RAL 5015) Flexible Control Cables
Capacitance unbalance with blue outer sheath for hazardous areas
max. 200 pF/100 m to hazard type -i- for intrinsically safe
Inductance approx. 0,70 mH/km installation acc. to DIN EN 60079-14
Attenuation section 12.2.2 (VDE 0165 part 1)
at 800 Hz approx. 1,1 dB/km 2-paired cables:
Radiation resistance cores stranded to a star quad
up to 80x106 cJ/kg (up to 80 Mrad) For Maxi-Termi-Point technique
Minimum bending radius (Maxi-Termi-Point = registered trade
fixed installation 6x cable mark AMP)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cable types are suitable for transmission of signals and measurements in the symmetric circuits of the control and regulation technology, and
for the transmission of data and process information in computer systems. Used in dry and damp premises, and in or under plaster in the open air for
fixed installation. Installation cables are not allowed for purposes of high current and power or burial installation.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Sheath Outer Cop. Weight AWG-No. Part no. No.pairs x Sheath Outer Cop. Weight AWG-No.
cross-sec. colour approx. weight approx. cross-sec. colour approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
48510 2 x 2 x 0,5 GY 7,0 51,0 94,0 20 48529 2 x 2 x 0,5 BU 7,0 51,0 94,0 20
48511 4 x 2 x 0,5 GY 8,6 87,0 154,0 20 48530 4 x 2 x 0,5 BU 8,6 87,0 154,0 20
48512 8 x 2 x 0,5 GY 12,0 144,0 259,0 20 48531 8 x 2 x 0,5 BU 12,0 144,0 259,0 20
48513 12 x 2 x 0,5 GY 13,1 196,0 340,0 20 48532 12 x 2 x 0,5 BU 13,1 196,0 340,0 20
48514 16 x 2 x 0,5 GY 14,3 249,0 431,0 20 48533 16 x 2 x 0,5 BU 14,3 249,0 431,0 20
48515 20 x 2 x 0,5 GY 15,5 299,0 494,0 20 48534 20 x 2 x 0,5 BU 15,5 299,0 494,0 20
48516 24 x 2 x 0,5 GY 19,4 348,0 604,0 20 48535 24 x 2 x 0,5 BU 19,4 348,0 604,0 20
48517 32 x 2 x 0,5 GY 20,5 444,0 737,0 20 48536 32 x 2 x 0,5 BU 20,5 444,0 737,0 20
48518 40 x 2 x 0,5 GY 22,5 537,0 844,0 20 48537 40 x 2 x 0,5 BU 22,5 537,0 844,0 20

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Tool - Multistrip 10

153
Data and Computer Cables

JE-LiHCH Bd industry electronic cable, halogen-free

Technical data Cable structure Properties


Industry electronic cable adapted to Bare copper, 7x0,3 mm Installation cables are not allowed for
DIN VDE 0815 Core insulation of polymer purposes of high current and power or
Conductor resistance at 20C compound type HI1 or HI2 burial installation.
39,2 Ohm/km to DIN VDE 0207 part 23 Tests
Temperature range Insulation wall thickness 0,3 mm Flame test acc. to
flexing -5C to +50C Core identification to DIN VDE 0815 DIN VDE 0482-332-3, BS 4066 part 3,
fixed installation -30C to +70C (with ring colours and ring groups) DIN EN 60332-3, IEC 60332-3 (previously
Operating peak voltage 225 V 2 cores twisted in pair, 4 pairs to a unit DIN VDE 0472 part 804 test method C)
(not for heavy current installation purposes) and several units stranded in layers (for Corrosiveness of combustion gases
Test voltage 2 pairs cable, 4 cores stranded to a quad) acc. to DIN VDE 0482 part 267,
core/core 500 V Foil wrapping DIN EN 50267-2-2, IEC 60754-2
core/screen 2000 V Copper braided screening, wire 0,2 mm, (equivalent DIN VDE 0472 part 813)
Insulation resistance approx. 85% coverage Smoke density acc. to DIN VDE 0482
min. 100 MOhm x km Outer sheath halogen-free part 1034-1+2, DIN EN 61034-1+2,
Mutual capacitance compound type HM1 or HM2 to IEC 61034-1+2, BS 7622 part 1+2
max. 120 nF/km at 800 Hz (this values DIN VDE 0207 part 24 (previously DIN VDE 0472 part 816)
may be extended at 20% with a make-up Sheath colour grey RAL (7032)
up to 4 pairs) Note
Capacitance unbalance at 800 Hz 2-paired cables:
max. 200 pF/100 m (20% of the values, cores stranded to a star quad
but one value up to 400 pF is allowed) AWG sizes are approximate equivalent
Minimum bending radius values. The actual cross-section is in mm.
7,5x cabel LS0H = Low Smoke Zero Halogen
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Caloric load values
see Technical Informations

Application
Halogen-free installation cables with improved characteristics in the case of fire are used for telephone transmission, measuring and signal purposes.
The copper screened design (C) protects the transmission circuits against electrical interferences. A fire propagation is prevented through high oxygen
index of the insulation material and produce no corrosive gases in case of fire. They are preferably used for telecommunication installations inside
buildings. These cables are suitable for fixed installation in areas with danger of fire, in dry and damp environments as well as in and under plaster.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part No.pairs x Core No. Outer Cop. Weight AWG-No. Part No.pairs x Core No. Outer Cop. Weight AWG-No.
no. cross-sec. approx. units approx. weight approx. no. cross-sec. approx. units approx. weight approx.
mm mm mm kg / km kg / km mm mm mm kg / km kg / km
34350 2 x 2 x 0,5 1,6 - 6,8 44,0 102,0 20 34354 20 x 2 x 0,5 1,6 5 16,4 288,0 555,0 20
34351 4 x 2 x 0,5 1,6 1 9,1 80,0 168,0 20 34355 32 x 2 x 0,5 1,6 8 19,6 439,0 852,0 20
34352 8 x 2 x 0,5 1,6 2 11,4 152,0 297,0 20 34356 40 x 2 x 0,5 1,6 10 21,7 531,0 1005,0 20
34353 12 x 2 x 0,5 1,6 3 13,3 192,0 357,0 20

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Tool - Multistrip 10

154
Data and Computer Cables

RD-H(St)H Bd instrumentation cable, halogen-free

Technical data Cable structure Properties


Halogen-free data transmission cable Bare copper-conductor, multi-wires The static screen protects the transmission
adapted to DIN VDE 0815 Conductor construction: circuits against outer electrical interferences
Coductor resistance (loop) 0,5 mm = 7x0,3 mm The halogen-free cables prevent the fire
max. 73,6 Ohm/km (0,5 mm) 1 mm = 7x0,43 mm propagation and compared to PVC cables
max. 36,8 Ohm/km (1,0 mm) Core insulation of halogen-free exist only a low smoke density under flame
Temperature range polymer compound influence
flexing -5C to +50C Core identification coloured This results no decomposition products which
fixed installation -30C to +70C pair-no.1: a-core = BU; b-core = RD destroy equipments, machines and buildings
Operating peak voltage max. 225 V pair-no.2: a-core = GY; b-core = YE by corrosion
(not for purposes of high pair-no.3: a-core = GN; b-core = BN Tests
current and power installation) pair-no.4: a-core = WH; b-core = BK Flame test acc. to
Test voltage Cores twisted in pairs, with short lay-length DIN VDE 0482-332-3, BS 4066 part 3,
core/core 500 V (approx. 20 pitch/m 50 mm) DIN EN 60332-3, IEC 60332-3 (previously
core/screen 2000 V 4 pairs stranded to a unit DIN VDE 0472 part 804 test method C)
Insulation resistance (unit labelled with numbers Corrosiveness of combustion gases
min. 100 MOhm x km printed plastic helix) acc. to DIN VDE 0482 part 267,
Mutual capacitance Units stranded in concentric layers DIN EN 50267-2-2, IEC 60754-2
at 800 Hz max. 100 nF/km Foil wrapping (equivalent DIN VDE 0472 part 813)
(this value may be exceeded by 20% Electrostatic screen of plastic coated Smoke density acc. to DIN VDE 0482
with a make-up up to 4 pairs) aluminium foil and drain wire tinned, 0,5 mm part 1034-1+2, IEC 61034-1+2,
Impedance Outer sheath of halogen-free, polymer DIN EN 61034-1+2, BS 7622 part 1+2
at 1 kHz (nominal values) compound, flame resistant (equivalent DIN VDE 0472 part 816)
450 Ohm (0,5 mm) Sheath colour grey (RAL 7032)
320 Ohm (1,0 mm) Note
Capacity unbalance AWG sizes are approximate equivalent
at 800 Hz max. 200 pF/100 m values. The actual cross-section is in mm.
(20% of the values, but one value
up to 200 pF is allowed)
Cross-talk attenuation
at min. 10 kHz, 60 dB/500 m
Line attenuation
at 1 kHz (nominal values)
1,2 dB/km (0,5 mm)
0,9 dB/km (1,0 mm)
Minimum bending radius
7,5x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Application
The halogen-free data transmission cable RD-H(St)H are used for measurement and control technology for transmission of analog and digital signals
up to frequencies of approx. 10 kHz. The twisted pairs with short pitches (<50 mm for 0,5 mm) and different lay-lengths which lead good cross-talk
attenuation values in a unit. These cables are used in inside buildings (in special cases in open air, but with sufficient protection against sunlight is
necessary).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
20200 2 x 2 x 0,5 7,0 26,0 70,0 20 20216 2x2x1 9,0 47,0 110,0 18
20201 4 x 2 x 0,5 9,0 46,0 110,0 20 20217 4x2x1 12,0 89,0 190,0 18
20202 8 x 2 x 0,5 11,6 86,0 190,0 20 20218 8x2x1 16,5 172,0 320,0 18
20203 12 x 2 x 0,5 13,5 127,0 240,0 20 20219 12 x 2 x 1 17,5 255,0 435,0 18
20204 16 x 2 x 0,5 14,0 167,0 300,0 20 20220 16 x 2 x 1 19,5 338,0 560,0 18
20205 20 x 2 x 0,5 16,0 209,0 360,0 20 20221 20 x 2 x 1 21,0 423,0 680,0 18
20206 24 x 2 x 0,5 17,5 250,0 420,0 20 20222 24 x 2 x 1 23,0 507,0 800,0 18
20207 28 x 2 x 0,5 19,0 290,0 480,0 20 20223 28 x 2 x 1 27,0 590,0 905,0 18
20208 32 x 2 x 0,5 21,0 331,0 570,0 20 20225 32 x 2 x 1 29,0 674,0 1080,0 18
20209 36 x 2 x 0,5 21,5 372,0 614,0 20 20226 36 x 2 x 1 30,0 757,0 1260,0 18
20210 40 x 2 x 0,5 22,5 412,0 680,0 20 20227 40 x 2 x 1 31,0 841,0 1330,0 18
20211 44 x 2 x 0,5 23,5 453,0 700,0 20 20228 44 x 2 x 1 34,0 924,0 1410,0 18
20212 48 x 2 x 0,5 24,0 494,0 790,0 20 20229 48 x 2 x 1 32,5 1008,0 1550,0 18
20213 64 x 2 x 0,5 30,0 658,0 1040,0 20 20230 64 x 2 x 1 39,0 1342,0 2000,0 18
20214 80 x 2 x 0,5 33,0 821,0 1300,0 20 20231 80 x 2 x 1 43,0 1676,0 2470,0 18
20215 96 x 2 x 0,5 36,0 986,0 1510,0 20 20232 96 x 2 x 1 47,0 2016,0 2970,0 18

Dimensions and specifications may be changed without prior notice. (RB01)

155
DRAG CHAIN CABLES

3
in

E
VD eld 29
ng

x
xe
ex

VD
ed
U

R/ shi E 0
xi
- fi
- fl

./
0 /

le

fix

ed

no
H A ed / VD
-f
U
C)

C)

-
ge

us

us

CS REG
e n es /
(

(
C

e
lta

di

di

se
re

re

t
V- -fre

ut tan

r
n
ra

ra

co
tu

tu

u
vo

E
ai
or
ra

ra

sis
n
g

A
d
ch
al

ge
in

in
pe

pe

re
do
re
in

ge
nd

nd

ag
lo

lo

re
m

L/
om

Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
N
PVC drag chain cables

JZ-HF -10 to +80 -40 to +80 300/500 7.5x 4x X X 160

MULTISPEED 500-PVC -15 to +80 -30 to +80 300/500 7.5x 4x X X X 162

JZ-HF-CY -10 to +80 -40 to +80 300/500 10x 5x X X X 163

MULTISPEED 500-C-PVC -15 to +80 -30 to +80 300/500 7.5x 4x X X X X 165

PUR drag chain cables

PUR-JZ-HF -20 to +80 -40 to +80 300/500 7.5x 4x X X X 167

MULTIFLEX 512 -PUR


-30 to +80 -40 to +80 300/500 5x 3x X X X X 169

MULTISPEED 500-PUR -30 to +80 -40 to +80 300/500 7.5x 4x X X X X 171

PUR-JZ-HF-YCP -20 to +80 -40 to +80 300/500 10x 5x X X X X 172

MULTIFLEX 512-C-PUR -30 to +80 -40 to +80 300/500 7.5x 4x X X X X X 174

MULTISPEED 500-C-PUR -30 to +80 -40 to +80 300/500 7.5x 4x X X X X X 176

MULTISPEED 500-TPE

-30 to +80 -40 to +80 300/500 5x 3x X X X X 177

MULTISPEED 500-C-TPE -30 to +80 -40 to +80 300/500 5x 3x X X X X X 179

Bio-oil resistant and microbe-resistant drag chain cables

BIOFLEX-500-JZ-HF -20 to +80 -40 to +80 300/500 10x 4x X X 181

BIOFLEX-500 -JZ-HF-C

-20 to +80 -40 to +80 300/500 15x 4x X X X 182

KOMPOSPEED JZ-HF-500 -30 to +90 -40 to +100 300/500 7.5x X X X X 184

KOMPOSPEED JZ-HF-500-C -30 to +90 -40 to +100 300/500 7.5x X X X X X 185

Data drag chain cables

SUPERTRONIC-PVC -5 to +70 -40 to +70 350 5x 3x X X 187

SUPERTRONIC-C-PVC -5 to +70 -40 to +70 350 7.5x 4x X X X 188

SUPERTRONIC -PUR
-5 to +70 -40 to +70 350 5x 3x X X X X 189

SUPERTRONIC-C-PUR -30 to +70 -40 to +70 350 7.5x 4x X X X X X X 190

SUPER-PAAR-TRONIC-C-PUR
-30 to +70 -40 to +70 350 10x 5x X X X X X X 191

SENSORFLEX-H -30 to +80 -40 to +80 350 5x/7,5x X X X X 192

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

157
SELECTION TABLE - DRAG CHAIN CABLES

ng
in

xi

g
/s 2
ce

fle

in
/
an

ex
ge U
(m
-
es ist

lta 0 /

- fl
us

)
-c t d

vo U
/s
di

io
)

C)
g ge
en

(m
ra

at
or

(
tin lta
er
m

re
in

s
25
e

el

nt
ra vo
ee

le

ui CSA
ov

nd

tu

s
c

yc
)

al
to

le
sp

ac

pe l

ra
ia
m

O ina
be

ov
r

.c
up

va
te

eq L/
er

pe
.

ge
.

ax

ax
ou

pr
ax
ax
m

om
.

at
in

U
m
=

Ap
M

M
0

Pa
M
M

M
M
(D
(1

Te
N
PVC drag chain cables
JZ-HF 10 7.5 x D 2 10 9 Mio PVC/PVC 300/500V -10 to +80 VDE 160 423
JZ-HF CY 10 10 x D 2 10 9 Mio PVC/CU/PVC 300/500V -10 to +80 VDE 163 427
MULTISPEED 500-PVC 100 7.5 x D 5 50 9 Mio PP/PVC 300/500V -15 to +80 162 425
MULTISPEED 500-C-PVC 100 7.5 x D 5 50 9 Mio PP/CU/PVC 300/500V -15 to +80 165 429
PUR & TPE drag chain cables
PUR-JZ-HF 15 7.5 x D 3 10 10 Mio PVC/PUR 300/500V -20 to +80 167 430
PUR-JZ-HF-YCP 15 10 x D 3 10 10 Mio PVC/CU/PUR 300/500V -20 to +80 172 436
MULTIFLEX 512-PUR 100 5xD 4 10 11 Mio PP/PUR 300/500V -30 to +80 169 431
MULTIFLEX 512-C-PUR 100 7.5 x D 4 10 11 Mio PP/CU/PUR 300/500V -30 to +80 174 437
MULTISPEED 500-PUR

450 7.5 x D 5 50 11 Mio PP/PUR 300/500V -30 to +80 171 433
MULTISPEED 500-C-PUR 450 7.5 x D 5 50 11 Mio PP/CU/PUR 300/500V -30 to +80 176 439
MULTISPEED 500-TPE 450 5xD 5 50 11 Mio PP/TPE 300/500V -30 to +80 177 441
MULTISPEED 500-C-TPE

450 5xD 5 50 11 Mio PP/CU/TPE 300/500V -30 to +80 179 443
Bio-oil resistant and microbe-resistant drag chain cables
BIOFLEX 500 JZ-HF 100 10 x D 4 10 11 Mio Poly/Poly 300/500V -20 to +80 181 -
BIOFLEX 500 JZ-HF-C
100 15 x D 4 10 11 Mio Poly/CU/Poly 300/500V -20 to +80 182 -
KOMPOSPEED JZ-HF-500 100 7.5 x D 4 10 10 Mio Poly/Poly 300/500V -30 to +90 184 -
KOMPOSPEED JZ-HF-500-C 100 7.5 x D 4 10 10 Mio Poly/CU/Poly 300/500V -30 to +90 185 -
Sensor cables
SUPERTRONIC-PVC 5 5xD 2 10 9 Mio PVC/PVC 350V -5 to +70 187 445
SUPERTRONIC -C-PVC
5 7.5 x D 2 10 9 Mio PVC/CU/PVC 350V -5 to +70 188 446
SUPERTRONIC-PUR 5 5xD 3 10 9 Mio PVC/PUR 350V -5 to +70 189 447
SUPERTRONIC-C-PUR 15 7.5 x D 4 10 9 Mio PP/CU/PUR 350V -30 to +70 190 449
SUPER-PAAR-TRONIC-C-PUR 30 10 x D 4 50 9 Mio PP/CU/PUR 350V -30 to +70 191 451
SENSORFLEX-H (Li12Y11Y) 30 5xD 5 10 11 Mio TPE/PUR 350V -30 to +80 192 -
SENSORFLEX-H (Li9Y11Y) 30 7.5 x D 5 10 11 Mio PP/PUR 350V -30 to +80 192 -

A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties and the selection tables cables in drag chains,
see pages 1030 and 1031.

158
PVC DRAG CHAIN CABLES
Cables for Drag Chains / PVC Cables for Drag Chains

JZ-HF flexible, number coded, control cable for drag chains, oil resistant,
meter marking

Technical data Cable structure Properties


Special PVC control cable, extreme flexibility Bare copper, extra fine wire conductors, to The materials used in manufacture are
due to special construction DIN VDE 0295 cl.6 col. 4, BS 6360 cl.6 and cadmium-free and contain no silicone
Requirements adapted to IEC 60228 cl.6 and free from substances harmful to
DIN VDE 0285-525-2-51 / Core insulation of special PVC the wetting properties of lacquers
DIN EN 50525-2-51 compound type Z 7225 Tests
Temperature range Core identification to DIN VDE 0293 PVC self-extinguishing and flame retardant
flexing -10C to +80C black cores with continuous white acc. to DIN VDE 0482-332-1-2,
fixed installation -40C to +80C numbering DIN EN 60332-1-2, IEC 60332-1 (equivalent
Nominal voltage U0/U 300/500 V Cores stranded in layers with optimal DIN VDE 0472 part 804 test method B)
Test voltage 4000 V selected lay-length Oil resistent to DIN VDE 0473-811-404/
Breakdown voltage min. 8000 V GN-YE conductor, 3 cores and above DIN EN 60811-404
Insulation resistance in the outer layer
min. 20 MOhm x km Core wrapping with fleece Note
Minimum bending radius Outer sheath of special PVC G = with green-yellow conductor
flexing 7,5x cable compound type TM5 to x = without green-yellow conductor (OZ)
fixed installation 4x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1 AWG sizes are approximate equivalent
Radiation resistance Colour grey (RAL 7001) values. The actual cross-section is in mm.
up to 80x106 cJ/kg (up to 80 Mrad) with meter marking Cleanroom qualification tested with analog
type. Please note "cleanroom qualified" when
ordering.
screened analogue type:
JZ-HF-CY, confer page 163
with UL-approval
MULTISPEED 500-PVC UL/CSA,
confer page 424

Application
JZ-HF cables are ideal for use in the machine tool industry, in robotics and machine production and anywhere where high flexibility is essential. These
cables have shown excellent performance in combination with standard cable trays. These cables are suitable for flexible use for medium mechanical
stresses with free movements. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors
with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation
in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15001 2 x 0,5 5,0 9,6 46,0 20 15019 2 x 0,75 5,4 14,4 58,0 19
15002 3 G 0,5 5,3 14,0 57,0 20 15020 3 G 0,75 5,7 22,0 73,0 19
15003 4 G 0,5 5,7 19,0 70,0 20 15021 4 G 0,75 6,4 29,0 77,0 19
15004 5 G 0,5 6,4 24,0 93,0 20 15022 5 G 0,75 7,0 36,0 119,0 19
15005 7 G 0,5 7,5 34,0 127,0 20 15023 7 G 0,75 8,3 50,0 165,0 19
15090 7 x 0,5 7,5 34,0 127,0 20 15024 10 G 0,75 10,1 72,0 216,0 19
15006 10 G 0,5 9,1 48,0 161,0 20 15025 12 G 0,75 10,2 86,0 247,0 19
15007 12 G 0,5 9,2 58,0 177,0 20 15026 14 G 0,75 10,9 101,0 284,0 19
15008 14 G 0,5 9,8 67,0 213,0 20 15027 16 G 0,75 11,5 115,0 320,0 19
15009 16 G 0,5 10,3 77,0 260,0 20 15028 18 G 0,75 12,1 130,0 356,0 19
15010 18 G 0,5 11,1 86,0 284,0 20 15029 20 G 0,75 12,8 144,0 453,0 19
15011 20 G 0,5 11,6 96,0 318,0 20 15030 25 G 0,75 14,9 180,0 498,0 19
15012 25 G 0,5 13,4 120,0 363,0 20 15031 30 G 0,75 15,2 216,0 510,0 19
15013 30 G 0,5 13,7 144,0 432,0 20 15032 34 G 0,75 16,6 245,0 550,0 19
15014 34 G 0,5 15,0 163,0 487,0 20 15033 36 G 0,75 16,6 259,0 570,0 19
15015 36 G 0,5 15,0 173,0 518,0 20 15034 42 G 0,75 18,1 302,0 600,0 19
15016 42 G 0,5 16,1 202,0 575,0 20 15035 50 G 0,75 20,0 360,0 700,0 19
15017 50 G 0,5 17,9 240,0 675,0 20 15036 61 G 0,75 22,1 432,0 820,0 19
15018 61 G 0,5 19,6 290,0 829,0 20 15091 65 G 0,75 22,7 439,0 841,0 19

Continuation

160
Cables for Drag Chains / PVC Cables for Drag Chains

JZ-HF flexible, number coded, control cable for drag chains, oil resistant,
meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15037 2x1 5,7 19,0 65,0 18 15073 2 x 2,5 7,7 48,0 130,0 14
15038 3G1 6,0 29,0 84,0 18 15074 3 G 2,5 8,4 72,0 160,0 14
15039 4G1 6,8 38,0 113,0 18 15075 4 G 2,5 9,1 96,0 200,0 14
15040 5G1 7,4 48,0 137,0 18 15076 5 G 2,5 10,2 120,0 268,0 14
15041
15042
15043
7G1
10 G 1
12 G 1
8,8
10,7
10,8
67,0
96,0
115,0
192,0
251,0
295,0
18
18
18
15077
15078
15079
7 G 2,5
10 G 2,5
12 G 2,5
12,2
15,0
15,2
168,0
240,0
288,0
357,0
486,0
572,0
14
14
14
C
15044 14 G 1 11,6 134,0 337,0 18 15080 14 G 2,5 16,1 336,0 612,0 14
15045 16 G 1 12,2 154,0 379,0 18 15081 16 G 2,5 17,2 384,0 702,0 14
15046 18 G 1 13,0 173,0 420,0 18 15082 18 G 2,5 18,1 432,0 800,0 14
15047 20 G 1 13,6 192,0 480,0 18 15083 20 G 2,5 19,2 480,0 920,0 14
15048 25 G 1 15,8 240,0 600,0 18 15084 25 G 2,5 22,5 600,0 1100,0 14
15049 30 G 1 16,4 288,0 695,0 18 15085 30 G 2,5 23,5 720,0 1400,0 14
15050 34 G 1 17,8 326,0 777,0 18 15086 34 G 2,5 25,2 816,0 1500,0 14
15051 36 G 1 17,8 346,0 825,0 18 15087 36 G 2,5 25,2 864,0 1600,0 14
15052 41 G 1 19,3 403,0 926,0 18 15088 42 G 2,5 27,4 1008,0 1800,0 14
15214 42 G 1 19,3 403,0 948,0 18 15089 50 G 2,5 30,0 1200,0 2100,0 14
15053 50 G 1 21,2 480,0 1092,0 18 15142 3G4 10,4 115,0 221,0 12
15092 61 G 1 23,7 586,0 1204,0 18 15143 4G4 11,4 154,0 260,0 12
15054 65 G 1 24,4 624,0 1400,0 18 15144 5G4 12,7 192,0 318,0 12
15055 2 x 1,5 6,4 29,0 91,0 16 15145 4G6 13,3 230,0 392,0 10
15056 3 G 1,5 6,8 43,0 117,0 16 15146 5G6 14,5 288,0 481,0 10
15057 4 G 1,5 7,4 58,0 147,0 16 15147 4 G 10 17,7 384,0 642,0 8
15058 5 G 1,5 8,3 72,0 181,0 16 15148 5 G 10 19,7 480,0 780,0 8
15059 7 G 1,5 9,9 101,0 273,0 16 15149 4 G 16 20,8 614,0 926,0 6
15060 10 G 1,5 11,9 144,0 344,0 16 15150 5 G 16 23,3 768,0 1135,0 6
15061 12 G 1,5 12,1 173,0 391,0 16
15062 14 G 1,5 12,9 202,0 457,0 16
15063 16 G 1,5 13,6 230,0 523,0 16
15064 18 G 1,5 14,5 259,0 590,0 16
15065 20 G 1,5 15,2 288,0 650,0 16
15066 25 G 1,5 17,8 360,0 801,0 16
15067 30 G 1,5 18,2 432,0 958,0 16
15068 34 G 1,5 19,7 490,0 1084,0 16
15069 36 G 1,5 19,7 518,0 1135,0 16
15070 42 G 1,5 21,5 605,0 1290,0 16
15071 50 G 1,5 23,7 720,0 1521,0 16
15072 60 G 1,5 25,3 864,0 1885,0 16
15215 61 G 1,5 26,2 878,0 1916,0 16
15216 65 G 1,5 27,2 936,0 1994,0 16

Dimensions and specifications may be changed without prior notice. (RC01)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

161
Cables for Drag Chains / PVC Cables for Drag Chains

MULTISPEED 500-PVC high flexible, safety against high bending


in drag chain systems, oil resistant, low torsion, meter marking

Technical data Cable structure Properties


Special drag chain cables for high Bare copper, fine wire conductors, Low adhesion
mechanical stress adapted to Unilay with short pitch length ozon- and uv-resistant
DIN VDE 0285-525-2-51/ Core insulation of special PP High property of alternating bending strength
DIN EN 50525-2-51 Core identification black cores with High resistant to mechanical strain
Temperature range continuous white numbering Long life durabilities due to low
flexing -15C to +80C GN-YE conductor, 3 cores and above friction-resistancen
fixed installation -30C to +80C Stranding: Better chemical resistance
Nominal voltage U0/U 300/500 V <7 cores: cores stranded in a layer with High stability
Test voltage 3000 V optimal lay-length around a filler as per Higher economical solution
Insulation resistance construction Reduced , results low weight of moving
min. 100 MOhm x km 7 cores: cores stranded with optimal materials
Minimum bending radius lay-length to bunch-construction with low The materials used in manufacture are
flexing 7,5x cable torsion strength, optimal selected short cadmium-free and contain no silicone
fixed installation 4x cable lay-length around a filler and free from substances harmful to
Radiation resistance Outer sheath of special PVC, the wetting properties of lacquers
up to 80x106 cJ/kg (up to 80 Mrad) especially resistant against fatigue strength, Tests
extruded as filler with pressure PVC self-extinguishing and flame retardant
Sheath colour black (RAL 9005) acc. to DIN VDE 0482-332-1-2,
with meter marking DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Oil resistance to DIN VDE 0473-811-404 /
DIN EN 60811-404

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED 500-C-PVC,
confer page 165

Application
HELUKABEL MULTISPEED 500-PVC are installed there, where the extreme requirements for the cables are necessary. The selected materials and
lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and low speed of movements.
These high flexible PVC control cables are suitable for shift- and bending stresses in machines and machine tool constructions. These are installed in
dry, moist rooms and in open air with free movement without tensile stress or forced movements. For applications which go beyond standard solutions
(for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for
drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24050 2 x 0,5 4,3 9,6 40,0 20 24068 5G1 6,7 48,0 101,0 18
24051 3 G 0,5 4,6 14,4 45,0 20 24069 7G1 11,1 67,0 140,0 18
24052 4 G 0,5 5,0 19,0 57,0 20 24070 12 G 1 12,0 115,0 227,0 18
24053 5 G 0,5 5,4 24,0 66,0 20 24071 18 G 1 14,8 173,0 351,0 18
24054 7 G 0,5 8,9 33,6 81,0 20 24072 25 G 1 17,2 240,0 489,0 18
24055 12 G 0,5 9,7 58,0 133,0 20 24073 3 G 1,5 6,4 43,0 88,0 16
24056 18 G 0,5 11,8 86,0 194,0 20 24074 4 G 1,5 7,0 58,0 110,0 16
24057 25 G 0,5 13,9 120,0 274,0 20 24075 5 G 1,5 7,8 72,0 130,0 16
24058 4 G 0,75 5,6 29,0 63,0 19 24076 7 G 1,5 13,0 101,0 182,0 16
24059 5 G 0,75 6,3 36,0 79,0 19 24077 12 G 1,5 14,2 173,0 319,0 16
24060 7 G 0,75 10,3 50,0 107,0 19 24078 18 G 1,5 17,5 259,0 420,0 16
24061 12 G 0,75 11,0 86,0 169,0 19 24079 25 G 1,5 20,1 360,0 604,0 16
24062 18 G 0,75 13,9 130,0 247,0 19 24080 4 G 2,5 8,8 96,0 172,0 14
24063 25 G 0,75 15,9 180,0 366,0 19 24081 5 G 2,5 9,8 120,0 219,0 14
24064 36 G 0,75 19,6 259,0 540,0 19 24082 7 G 2,5 16,1 168,0 303,0 14
24065 42 G 0,75 21,5 302,0 630,0 19 24083 12 G 2,5 17,8 288,0 504,0 14
24066 3G1 5,4 29,0 69,0 18 24084 18 G 2,5 21,8 432,0 754,0 14
24067 4G1 5,9 38,4 86,0 18 24085 25 G 2,5 24,4 600,0 940,0 14

Dimensions and specifications may be changed without prior notice. (RC01)

162
Cables for Drag Chains / PVC Cables for Drag Chains

JZ-HF-CY high flexible, screened control cable for drag chains,


oil resistant, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special PVC control cable, extreme flexibility Bare copper, extra fine wire conductors, to The materials used in manufacture are
due to special construction DIN VDE 0295 cl.6 col. 4, BS 6360 cl.6 and cadmium-free and contain no silicone
Requirements adapted to IEC 60228 cl.6 and free from substances harmful to
DIN VDE 0285-525-2-51/ Core insulation of special PVC Z 7225 the wetting properties of lacquers
DIN EN 50525-2-51 Core identification to DIN VDE 0293 Tests
Temperature range black cores with continuous white PVC self-extinguishing and flame retardant
flexing -10C to +80C numbering acc. to DIN VDE 0482-332-1-2,
fixed installation -40C to +80C GN-YE conductor, 3 cores and above DIN EN 60332-1-2, IEC 60332-1 (equivalent
Nominal voltage U0/U 300/500 V in the outer layer DIN VDE 0472 part 804 test method B)
Test voltage 4000 V Cores stranded in layers with optimal selected oil resistant to DIN VDE 0473-811-404 /
Breakdown voltage min. 8000 V lay-length DIN EN 60811-404
Insulation resistance Core wrapping with fleece PVC-inner sheath
min. 20 MOhm x km construction with Cu-screening, tinned, Note
Minimum bending radius approx. 85% G = with green-yellow conductor
flexing 10x cable Minimum coverage 85% x = without green-yellow conductor (OZ)
fixed installation 5x cable Outer sheath of special PVC AWG sizes are approximate equivalent
Radiation resistance compound type TM5 to values. The actual cross-section is in mm.
up to 80x106 cJ/kg (up to 80 Mrad) DIN VDE 0207-363-4-1/DIN EN 50363-4-1 Please note the cleanroom qualification when
Colour grey (RAL 7001) ordering.
with meter marking unscreened analogue type:
JZ-HF, confer page 160
with UL-approval
JZ-HF-FCY, confer page 425

Application
JZ-HF cables are ideal for use in the machine tool industry, in robotics and machine production and anywhere where high flexibility is essential. These
cables have shown excellent performance in combination with standard cable trays. These cables are suitable for flexible use for medium mechanical
stresses with free movements. The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control
cable for the above application. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors
with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation
in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15930 2 x 0,5 7,2 30,0 90,0 20 15945 2 x 0,75 7,6 39,0 105,0 19
15931 3 G 0,5 7,5 38,0 115,0 20 15946 3 G 0,75 8,1 49,0 128,0 19
15932 4 G 0,5 8,1 48,0 140,0 20 15947 4 G 0,75 8,6 60,0 184,0 19
15933 5 G 0,5 8,6 64,0 168,0 20 15948 5 G 0,75 9,4 70,0 200,0 19
15934 7 G 0,5 9,9 70,0 217,0 20 15949 7 G 0,75 10,5 95,0 269,0 19
15935 12 G 0,5 11,6 100,0 274,0 20 15885 10 G 0,75 12,6 110,0 327,0 19
15876 14 G 0,5 12,2 135,0 332,0 20 15950 12 G 0,75 12,9 140,0 366,0 19
15877 16 G 0,5 13,0 145,0 388,0 20 15886 14 G 0,75 13,4 163,0 426,0 19
15936 18 G 0,5 13,8 154,0 445,0 20 15887 16 G 0,75 14,2 187,0 487,0 19
15937 20 G 0,5 14,3 160,0 497,0 20 15951 18 G 0,75 14,8 211,0 547,0 19
15878 21 G 0,5 14,8 175,0 500,0 20 15888 20 G 0,75 15,5 216,0 551,0 19
15938 25 G 0,5 16,1 240,0 505,0 20 15889 21 G 0,75 16,2 272,0 590,0 19
15879 30 G 0,5 16,6 280,0 515,0 20 15952 25 G 0,75 17,7 322,0 600,0 19
15880 34 G 0,5 17,7 290,0 530,0 20 15890 30 G 0,75 18,2 414,0 650,0 19
15881 36 G 0,5 17,7 300,0 572,0 20 15891 34 G 0,75 19,8 473,0 685,0 19
15882 42 G 0,5 19,2 330,0 605,0 20 15892 36 G 0,75 19,8 500,0 720,0 19
15883 50 G 0,5 21,2 393,0 742,0 20 15893 42 G 0,75 21,0 583,0 800,0 19
15894 50 G 0,75 23,1 695,0 954,0 19

Continuation

163
Cables for Drag Chains / PVC Cables for Drag Chains

JZ-HF-CY high flexible, screened control cable for drag chains,


oil resistant, EMC-preferred type, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15961 2x1 8,1 50,0 115,0 18 15925 3 G 2,5 10,8 140,0 215,0 14
15962 3G1 8,4 60,0 142,0 18 15926 4 G 2,5 11,5 159,0 264,0 14
15963 4G1 9,0 73,0 196,0 18 15927 5 G 2,5 12,9 194,0 344,0 14
15964 5G1 9,8 81,0 271,0 18 15928 7 G 2,5 15,1 234,0 410,0 14
15965 7G1 11,2 114,0 307,0 18 15929 12 G 2,5 18,4 390,0 721,0 14
15966 12 G 1 13,4 186,0 474,0 18 15155 3G4 13,0 178,0 292,0 12
15967 18 G 1 15,7 254,0 622,0 18 15156 4G4 14,2 222,0 372,0 12
15968 25 G 1 19,0 365,0 828,0 18 15157 5G4 15,6 328,0 448,0 12
15969 34 G 1 21,0 500,0 1049,0 18 15158 4G6 16,0 305,0 526,0 10
15970 41 G 1 22,7 576,0 1257,0 18 15159 5G6 17,5 441,0 632,0 10
15971 50 G 1 24,5 681,0 1437,0 18 15160 4 G 10 21,2 485,0 838,0 8
15972 65 G 1 27,7 932,0 1823,0 18 15161 5 G 10 23,2 610,0 998,0 8
15976 2 x 1,5 8,6 64,0 170,0 16 15162 4 G 16 24,1 840,0 1225,0 6
15977 3 G 1,5 9,0 84,0 203,0 16 15163 5 G 16 27,0 1050,0 1560,0 6
15978 4 G 1,5 9,8 99,0 243,0 16
15979 5 G 1,5 10,5 120,0 288,0 16
15980 7 G 1,5 12,5 148,0 403,0 16
15981 12 G 1,5 14,8 274,0 592,0 16
15982 18 G 1,5 17,3 386,0 844,0 16
15983 25 G 1,5 21,0 584,0 1155,0 16
15152 41 G 1,5 24,8 867,0 1227,0 16
15153 50 G 1,5 27,3 970,0 1445,0 16
15154 61 G 1,5 29,8 1028,0 1724,0 16

Dimensions and specifications may be changed without prior notice. (RC01)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

164
Cables for Drag Chains / PVC Cables for Drag Chains

MULTISPEED 500-C-PVC high flexible, safety against high


bending in drag chain systems, oil resistant, low torsion, screened, EMC-preferred type,
meter marking

Technical data Cable structure Properties


Special drag chain cables for high Bare copper, fine wire conductors, Low adhesion
mechanical stress adapted to Unilay with short pitch length ozon- and uv- resistant
DIN VDE 0285-525-2-51 / Core insulation of special PP High property of alternating bending strength
DIN EN 50525-2-51 Core identification black cores with Long life durability due to low
Temperature range continuous white numbering friction-resistance
flexing -15C to +80C GN-YE conductor, 3 cores and above Better chemical resistance
fixed installation -30C to +80C Stranding: High stability
Nominal voltage U0/U 300/500 V <7 cores: cores stranded in a layer with Higher economical solution
Test voltage 3000 V optimal lay-length around a filler as per Reduced , results low weight of moving
Insulation resistance construction materials
min. 100 MOhm x km 7 cores: cores stranded with optimal The materials used in manufacture are
Minimum bending radius lay-length to bunch-construction with cadmium-free and contain no silicone
flexing 7,5x cable low torsion strength, optimal selected short and free from substances harmful to
fixed installation 4x cable lay-length around a filler the wetting properties of lacquers
Coupling resistance Special-PVC inner sheath YM2 extruded as Tests
max. 250 Ohm x km filler with pressure grey (RAL 7001) PVC self-extinguishing and flame retardant
Radiation resistance Tinned copper braidet screen, acc. to DIN VDE 0482-332-1-2,
up to 80x106 cJ/kg (up to 80 Mrad) coverage 85% max., with optimal bunch DIN EN 60332-1-2/IEC 60332-1 (equivalent
Fleece separator, ensure good dismantling DIN VDE 0472 part 804 test method B)
ability Oil resistance to DIN VDE 0473-811-404 /
Outer sheath of special PVC DIN EN 60811-404
especially resistant against fatigue strength
Sheath colour black (RAL 9005) Note
with meter marking G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
MULTISPEED 500-PVC, confer page 162

Application
HELUKABEL MULTISPEED 500-C-PVC are installed there, where the extreme requirements for the cables are necessary. The selected materials and
lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and low speed of movements.
These high flexible PVC control cables are suitable for shift- and bending stresses in machines and machine tool constructions. These are installed in
dry, moist rooms and in open air with free movement without tensile stress or forced movements. These screened cables are particularly suitable for
the interference-free transmission in instrumentation and control engineering applications. For applications which go beyond standard solutions (for
example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for
drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24086 2 x 0,5 6,2 30,0 88,0 20 24103 3G1 7,6 59,0 131,0 18
24087 3 G 0,5 6,7 36,0 101,0 20 24104 4G1 8,1 70,0 164,0 18
24088 4 G 0,5 7,2 42,0 116,0 20 24105 5G1 8,9 84,0 198,0 18
24089 5 G 0,5 7,6 48,0 146,0 20 24106 7G1 13,6 106,0 252,0 18
24090 7 G 0,5 11,4 64,0 181,0 20 24107 12 G 1 14,6 174,0 410,0 18
24091 9 G 0,5 11,4 80,0 219,0 20 24108 18 G 1 18,4 240,0 550,0 18
24092 12 G 0,5 12,4 105,0 271,0 20 24109 25 G 1 21,0 332,0 756,0 17
24093 18 G 0,5 14,7 137,0 374,0 20 24110 3 G 1,5 8,4 75,0 166,0 16
24094 25 G 0,5 17,1 210,0 542,0 20 24111 4 G 1,5 9,1 90,0 199,0 16
24095 2 x 0,75 6,8 40,0 96,0 19 24112 5 G 1,5 10,2 108,0 229,0 16
24096 3 G 0,75 7,3 48,0 111,0 19 24113 7 G 1,5 15,7 157,0 304,0 16
24097 4 G 0,75 7,8 55,0 140,0 19 24114 12 G 1,5 17,4 240,0 502,0 16
24098 5 G 0,75 8,3 66,0 161,0 19 24115 18 G 1,5 21,3 355,0 709,0 16
24099 7 G 0,75 12,7 85,0 227,0 19 24116 25 G 1,5 24,3 448,0 939,0 16
24100 12 G 0,75 13,7 135,0 317,0 19 24117 4 G 2,5 11,2 134,0 270,0 14
24101 18 G 0,75 17,1 190,0 486,0 19 24118 5 G 2,5 12,2 175,0 335,0 14
24102 25 G 0,75 19,5 275,0 651,0 19

Dimensions and specifications may be changed without prior notice. (RC01)

165
PUR DRAG CHAIN CABLES
Cables for Drag Chains / PUR Cables for Drag Chains

PUR-JZ-HF high flexible, cable for drag chains, abrasion and coolant resistant,
meter marking

Technical data Cable structure Properties


Special polyurethane control cable adapted Bare copper, extra fine wire conductors, Suitable for outdoor lying and resistant to
to DIN VDE 0285-525-1/ DIN EN 50525-1 bunch stranded to DIN VDE 0295 cl.6, UV-radiation, oxygen, ozone and hydrolysis.
Temperature range BS 6360 cl.6 and IEC 60228 cl.6 Conditionally resistant to microbes
flexing -20C to +80C Oil resistant PVC core insulation, TI2 in Adhesion-low
fixed installation -40C to +80C adapted to DIN VDE 0207-363-3 / The materials used in manufacture are
Nominal voltage U0/U 300/500 V DIN EN 50363-3, for better sliding abilities cadmium-free and contain no silicone
Test voltage 4000 V Core identification to DIN VDE 0293 and free from substances harmful to
Breakdown voltage min. 8000 V black cores with continuous white the wetting properties of lacquers
Insulation resistance numbering
min. 20 MOhm x km GN-YE conductor, 3 cores and above Note
Minimum bending radius in the outer layer AWG sizes are approximate equivalent
flexing 7,5x cable Cores stranded in layers with optimal values. The actual cross-section is in mm.
fixed installation 4x cable selected lay-length G = with green-yellow conductor
Radiation resistance Core wrapping with fleece x = without green-yellow conductor (OZ)
up to 100x106 cJ/kg (up to 100 Mrad) Outer sheath of special full-polyurethane Cross-linked types also available on request.
TMPU, to DIN VDE 0207-363-10-2/ screened analogue type:
DIN EN 50363-10-2 PUR-JZ-HF-YCP, confer page 172
Colour grey (RAL 7001)
with meter marking

Application
PUR-JZ-HF is an extremely robust cable noted for its good tear and abrasion resistance. Due to its good performance with mineral oils and especially
in connection with coolants, this cable is well suited for use in the machinery, tool making and steel industries in critical areas. Its high abrasion resistance
and good flexing ability make it quick and easy to install and, with its low bending radius, ideal for use with cable trays. For applications which go
beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend
for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15520 2 x 0,5 5,5 9,6 45,0 20 15556 2x1 6,3 19,2 64,0 18
15521 3 G 0,5 6,0 14,4 56,0 20 15557 3G1 6,6 29,0 83,0 18
15522 4 G 0,5 6,4 19,1 69,0 20 15558 4G1 7,1 38,5 113,0 18
15523 5 G 0,5 6,9 24,0 92,0 20 15559 5G1 7,8 48,0 137,0 18
15524 7 G 0,5 7,9 33,6 126,0 20 15560 7G1 9,0 67,0 191,0 18
16161 7 x 0,5 7,8 33,6 126,0 20 15561 8G1 9,9 77,0 218,0 18
15525 8 G 0,5 8,6 38,0 136,0 20 15562 10 G 1 11,1 96,0 251,0 18
15526 10 G 0,5 9,7 48,0 158,0 20 15563 12 G 1 11,1 115,0 294,0 18
15527 12 G 0,5 9,9 58,0 176,0 20 15564 14 G 1 12,1 134,0 337,0 18
15528 14 G 0,5 10,4 67,0 212,0 20 15565 18 G 1 13,6 173,0 420,0 18
15529 18 G 0,5 11,4 86,4 283,0 20 15566 21 G 1 14,2 196,0 504,0 18
15530 21 G 0,5 12,1 96,0 310,0 20 15567 25 G 1 16,1 240,0 600,0 18
15531 25 G 0,5 13,5 120,0 330,0 20 15568 32 G 1 17,6 308,0 732,0 18
15532 30 G 0,5 14,2 144,0 390,0 20 15569 34 G 1 18,4 326,0 776,0 18
15533 34 G 0,5 15,2 163,0 420,0 20 15570 41 G 1 19,7 394,0 925,0 18
15534 42 G 0,5 16,2 202,0 500,0 20 15571 42 G 1 19,7 403,0 949,0 18
15535 50 G 0,5 18,0 240,0 580,0 20 15572 50 G 1 21,7 480,0 1092,0 18
15538 2 x 0,75 6,0 14,4 57,0 19 15573 65 G 1 30,9 624,0 1400,0 18
15539 3 G 0,75 6,3 21,6 72,0 19 15575 2 x 1,5 6,8 29,0 90,0 16
15540 4 G 0,75 6,8 29,0 97,0 19 15576 3 G 1,5 7,2 43,0 117,0 16
15541 5 G 0,75 7,4 36,0 119,0 19 15577 4 G 1,5 7,7 58,0 147,0 16
15542 7 G 0,75 8,7 50,0 165,0 19 15578 5 G 1,5 8,6 72,0 181,0 16
15543 8 G 0,75 9,5 58,0 189,0 19 15579 7 G 1,5 10,3 101,0 274,0 16
15544 10 G 0,75 10,7 72,0 214,0 19 15580 8 G 1,5 11,0 115,0 313,0 16
15545 12 G 0,75 10,9 86,0 247,0 19 15581 10 G 1,5 12,7 144,0 344,0 16
15546 14 G 0,75 11,5 101,0 283,0 19 15582 12 G 1,5 12,7 173,0 391,0 16
15547 18 G 0,75 12,7 130,0 356,0 19 15583 14 G 1,5 13,4 202,0 457,0 16
15548 21 G 0,75 13,4 151,0 502,0 19 15584 18 G 1,5 15,1 259,0 589,0 16
15549 25 G 0,75 15,0 180,0 698,0 19 15585 21 G 1,5 16,2 302,0 680,0 16
15550 30 G 0,75 15,8 216,0 720,0 19 15586 25 G 1,5 18,0 360,0 801,0 16
15551 34 G 0,75 17,2 245,0 770,0 19 15587 30 G 1,5 18,7 410,0 938,0 16
15552 42 G 0,75 18,5 302,0 840,0 19 15588 34 G 1,5 20,6 490,0 1048,0 16
15553 50 G 0,75 20,1 360,0 990,0 19 15589 42 G 1,5 22,4 605,0 1290,0 16

Continuation

167
Cables for Drag Chains / PUR Cables for Drag Chains

PUR-JZ-HF high flexible, cable for drag chains, abrasion and coolant resistant,
meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15590 50 G 1,5 24,2 720,0 1520,0 16 15637 4G6 13,9 230,0 500,0 10
15591 61 G 1,5 32,4 889,0 1850,0 16 15638 5G6 15,4 288,0 580,0 10
15592 65 G 1,5 33,6 940,0 1970,0 16 15639 7G6 18,0 403,0 800,0 10
15620 2 x 2,5 8,5 48,0 128,0 14 15654 1 G 10 8,9 96,0 152,0 8
15621 3 G 2,5 9,0 72,0 160,0 14 15641 3 G 10 16,2 288,0 660,0 8
15622 4 G 2,5 9,9 96,0 200,0 14 15642 4 G 10 18,1 384,0 750,0 8
15623 5 G 2,5 11,0 120,0 268,0 14 15643 5 G 10 20,3 480,0 990,0 8
15624 7 G 2,5 12,8 168,0 357,0 14 15644 7 G 10 24,3 672,0 1300,0 8
15625 12 G 2,5 16,2 288,0 571,0 14 15655 1 G 16 10,0 154,0 215,0 6
15626 14 G 2,5 17,1 336,0 612,0 14 15645 4 G 16 21,1 614,0 1200,0 6
15627 18 G 2,5 19,1 432,0 800,0 14 15646 5 G 16 23,5 768,0 1500,0 6
15628 25 G 2,5 22,8 600,0 1100,0 14 15647 7 G 16 28,7 1075,0 1900,0 6
15630 2x4 10,1 77,0 190,0 12 15656 1 G 25 11,1 240,0 320,0 4
15631 3G4 10,9 115,0 250,0 12 15648 4 G 25 34,0 960,0 1700,0 4
15632 4G4 12,0 154,0 320,0 12 15649 4 G 35 37,0 1344,0 2300,0 2
15633 5G4 13,4 192,0 400,0 12 15650 4 G 50 44,0 1920,0 2500,0 1
15634 7G4 16,0 269,0 550,0 12 15651 4 G 70 53,0 2688,0 4600,0 2/0
15653 1G6 7,3 58,0 81,0 10 15652 4 G 95 59,0 3648,0 6400,0 3/0
15636 3G6 12,8 173,0 350,0 10

Dimensions and specifications may be changed without prior notice. (RC02)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

168
Cables for Drag Chains / PUR Cables for Drag Chains

MULTIFLEX 512-PUR special cable for drag chains,


halogen-free, meter marking

Technical data Cable structure Properties


Special drag chain cables for high mechanical Bare copper, extra fine wire conductors, Very good oil resistant
stress, adapted to DIN VDE 0285-525-2-21/ bunch stranded to DIN VDE 0295 cl.6, Guaranteed permanent application in
DIN EN 50525-2-21 col. 4, BS 6360 cl.6 and IEC 60228 cl.6 multi-shift operation under extreme high
Temperature range Core insulation of special PP bending stress
flexing -30C to +80C Core identification black cores with Adhesion-low
fixed installation -40C to +80C continuous white numbering High resistant to mechanical strain
Nominal voltage U0/U 300/500 V GN-YE conductor, 3 cores and above High property of alternating bending strength
Test voltage 3000 V in the outer layer Long life durabilities through low
Insulation resistance Cores stranded in layers with optimal friction-resistance by using the PP-insulation
min. 100 MOhm x km selected lay-length High tensile strength-, abrasion- and impact
Minimum bending radius Special core wrapping over each layer (up to resistant at low temperature
flexing 5x cable 4 mm without core wrapping over the outer Resistant to weather, ozone and
fixed installation 3x cable layer) UV-radiation, solvents, acids and alkalis,
Alternating bending cycles Outer sheath of special full-polyurethane hydraulic liquidity and hydrolysis
approx. 10 million TMPU, to DIN VDE 0207-363-10-2 / The materials used in manufacture are
Radiation resistance DIN EN 50363-10-2 cadmium-free and contain no silicone
up to 50x106 cJ/kg (up to 50 Mrad) Colour grey (RAL 7001) outer surface mat and free from substances harmful to
with meter marking the wetting properties of lacquers

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified" when
ordering.
screened analogue type:
MULTIFLEX 512-C-PUR ,
confer page 174

Application
The special cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics, for movable automated
machinery parts and multi-shift operation. Those cables are developed according to the newest state of technology improvement. These high flexible
control cables with sliding abilities guaranteed an optimum service life durabilities and also very economic by using the PP-core insulation and the
PUR-outer sheath. The PUR material is adhesion-low and cut-resistant. For applications which go beyond standard solutions (for example for composting
appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy
guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see
lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22501 2 x 0,5 5,5 9,6 38,0 20 22512 2 x 0,75 6,2 14,4 47,0 19
22502 3 G 0,5 5,8 14,4 46,0 20 22513 3 G 0,75 6,5 21,6 58,0 19
22503 4 G 0,5 6,4 19,0 59,0 20 22514 4 G 0,75 7,0 29,0 69,0 19
22504 5 G 0,5 7,0 24,0 68,0 20 22515 5 G 0,75 7,8 36,0 85,0 19
22505 7 G 0,5 8,1 33,6 88,0 20 22516 7 G 0,75 9,0 50,0 118,0 19
22506 12 G 0,5 9,9 58,0 131,0 20 22517 12 G 0,75 11,0 86,0 183,0 19
22507 18 G 0,5 11,5 86,0 197,0 20 22518 18 G 0,75 13,0 130,0 270,0 19
22508 20 G 0,5 12,0 96,0 260,0 20 22519 20 G 0,75 13,5 144,0 290,0 19
22509 25 G 0,5 13,7 120,0 282,0 20 22520 25 G 0,75 15,4 180,0 374,0 19
22510 30 G 0,5 14,3 144,0 315,0 20 22521 30 G 0,75 16,2 216,0 420,0 19
22511 36 G 0,5 15,3 172,0 374,0 20 22522 36 G 0,75 17,6 259,0 498,0 19

Continuation

169
Cables for Drag Chains / PUR Cables for Drag Chains

MULTIFLEX 512-PUR special cable for drag chains,


halogen-free, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22523 2x1 6,9 19,2 55,0 18 22545 2 x 2,5 9,2 48,0 115,0 14
22524 3G1 7,4 29,0 70,0 18 22546 3 G 2,5 9,7 72,0 162,0 14
22525 4G1 8,0 38,0 86,0 18 22547 4 G 2,5 10,5 96,0 196,0 14
22526 5G1 8,7 48,0 102,0 18 22548 5 G 2,5 11,6 120,0 230,0 14
22527 7G1 10,2 67,0 143,0 18 22549 7 G 2,5 13,8 168,0 312,0 14
22528 12 G 1 12,6 115,0 225,0 18 22550 12 G 2,5 16,9 288,0 532,0 14
22529 18 G 1 14,8 173,0 334,0 18 22551 18 G 2,5 20,0 432,0 762,0 14
22530 20 G 1 15,8 192,0 370,0 18 22552 20 G 2,5 21,2 480,0 858,0 14
22531 25 G 1 18,1 240,0 460,0 18 22553 25 G 2,5 24,4 600,0 998,0 14
22532 30 G 1 18,5 288,0 530,0 18 22554 4G4 13,2 154,0 283,0 12
22533 36 G 1 20,1 346,0 625,0 18 22555 5G4 14,6 192,0 349,0 12
22878 41 G 1 22,0 410,0 779,0 18 22556 7G4 17,6 269,0 498,0 12
22879 50 G 1 24,0 498,0 953,0 18 22557 4G6 14,4 230,0 432,0 10
22880 65 G 1 27,2 650,0 1205,0 18 22558 5G6 15,9 288,0 529,0 10
22534 2 x 1,5 7,6 29,0 70,0 16 22559 7G6 19,2 403,0 782,0 10
22535 3 G 1,5 8,1 43,0 90,0 16 22560 4 G 10 18,4 384,0 685,0 8
22536 4 G 1,5 8,7 58,0 106,0 16 22561 5 G 10 20,7 480,0 817,0 8
22537 5 G 1,5 9,7 72,0 145,0 16 22562 7 G 10 24,7 672,0 1023,0 8
22538 7 G 1,5 11,3 101,0 205,0 16 22563 4 G 16 21,3 614,0 1042,0 6
22539 12 G 1,5 13,8 173,0 320,0 16 22564 5 G 16 23,8 768,0 1292,0 6
22540 18 G 1,5 16,3 259,0 465,0 16 22565 7 G 16 28,6 1075,0 1709,0 6
22541 20 G 1,5 17,3 288,0 510,0 16
22542 25 G 1,5 19,8 360,0 650,0 16
22543 30 G 1,5 20,3 432,0 750,0 16
22544 36 G 1,5 22,2 518,0 880,0 16
22881 42 G 1,5 24,0 628,0 1209,0 16
22882 50 G 1,5 26,2 749,0 1449,0 16
22883 61 G 1,5 28,9 912,0 1712,0 16

Dimensions and specifications may be changed without prior notice. (RC02)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

170
Cables for Drag Chains / PUR Cables for Drag Chains

MULTISPEED 500-PUR safety against high bending in drag chain


systems, low torsion, halogen-free, meter marking

Technical data Cable structure Properties


Special drag chain cables for high mechanical Bare copper, fine wire conductors, Low adhesion
stress adapted to Unilay with short pitch length Halogen-free
DIN VDE 0285-525-2-51 / Core insulation of special PP Oil resistance
DIN EN 50525-2-51 and Core identification black cores with Better chemical resistance
DIN VDE 0285-525-2-21/ continuous white numbering UV and ozone resistance
DIN EN 50525-2-21 GN-YE conductor, 3 cores and above Higher economical solution
Temperature range Stranding: Reduced , results low weight of moving
flexing -30C to +80C <7 cores: cores stranded in a layer with materials
fixed installation -40C to +80C optimal lay-length around a filler as per High property of alternating bending strength
Nominal voltage U0/U 300/500 V construction High resistant to mechanical strain
Test voltage 3000 V 7 cores: cores stranded with optimal Long life durabilitys due to low
Insulation resistance lay-length to bunch-construction with low friction-resistance
min. 100 MOhm x km torsion strength, optimal selected short High tensile strength, abrasion- and impact
Minimum bending radius lay-length around a filler resistance at low temperature
flexing 7,5x cable Special-PUR outer sheath, Tear resistance and high stability
fixed installation 4x cable extruded as filler with pressure The materials used in manufacture are
Radiation resistance Sheath colour black (RAL 9005) cadmium-free and contain no silicone
up to 100x106 cJ/kg (up to 100 Mrad) with meter marking and free from substances harmful to
the wetting properties of lacquers

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
screened analogue type:
MULTISPEED 500-C-PUR,
confer page 176

Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and wet rooms
and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are installed
there, where the problems appear for the application in permanent stresses e. g. in energy drag chains, industry robotics, production lines, automatic
control systems and permanent movable machinery parts for multi-shift operation. These cables are installed everywhere, where high requirements
for the flexibility, abrasion, oxygen and chemical resistance are necessary. For applications which go beyond standard solutions we recommend for
our especially developed enquiry sheet for energy guiding systems.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24119 2 x 0,5 4,3 9,6 41,0 20 24138 5G1 6,7 48,0 84,0 18
24120 3 G 0,5 4,6 14,4 48,0 20 24139 7G1 11,1 67,0 111,0 18
24121 4 G 0,5 5,0 19,0 62,0 20 24140 12 G 1 12,0 115,0 200,0 18
24122 5 G 0,5 5,4 24,0 70,0 20 24141 18 G 1 14,8 173,0 286,0 18
24123 7 G 0,5 8,9 33,6 88,0 20 24142 25 G 1 17,2 240,0 370,0 18
24124 12 G 0,5 9,7 58,0 131,0 20 24143 3 G 1,5 6,4 43,0 81,0 16
24125 18 G 0,5 11,8 86,0 204,0 20 24144 4 G 1,5 7,0 58,0 102,0 16
24126 25 G 0,5 13,9 120,0 266,0 20 24145 5 G 1,5 7,8 72,0 121,0 16
24127 3 G 0,75 5,2 21,6 51,0 19 24146 7 G 1,5 13,0 101,0 164,0 16
24128 4 G 0,75 5,6 29,0 68,0 19 24147 12 G 1,5 14,2 173,0 293,0 16
24129 5 G 0,75 6,3 36,0 73,0 19 24148 18 G 1,5 17,5 259,0 450,0 16
24130 7 G 0,75 10,3 50,0 92,0 19 24149 25 G 1,5 20,1 360,0 631,0 16
24131 12 G 0,75 11,0 86,0 170,0 19 24150 4 G 2,5 8,8 86,0 173,0 14
24132 18 G 0,75 13,9 130,0 257,0 19 24151 5 G 2,5 9,8 120,0 220,0 14
24133 25 G 0,75 15,9 180,0 280,0 19 24152 7 G 2,5 16,1 168,0 290,0 14
24134 36 G 0,75 19,6 260,0 411,0 19 24153 12 G 2,5 17,8 288,0 504,0 14
24135 42 G 0,75 21,5 302,0 608,0 19 24154 18 G 2,5 21,8 432,0 719,0 14
24136 3G1 5,4 29,0 59,0 18 24155 25 G 2,5 24,4 600,0 940,0 14
24137 4G1 5,9 38,0 71,0 18

Dimensions and specifications may be changed without prior notice. (RC02)

171
Cables for Drag Chains / PUR Cables for Drag Chains

PUR-JZ-HF-YCP EMC-preferred type, cable for drag chains, screened,


PUR-outer sheath, meter marking

Technical data Cable structure Properties


Special polyurethane control cable adapted to Bare copper, extra fine wire conductors, Suitable for outdoor lying and resistant to
DIN VDE 0285-525-1 / DIN EN 50525-1 bunch stranded to DIN VDE 0295 cl.6, UV-radiation, oxygen, ozone and hydrolysis.
Temperature range col. 4, BS 6360 cl.6 and IEC 60228 cl.6 Conditionally resistant to microbes
flexing -20C to +80C Oil resistant PVC core insulation TI2, in Adhesion-low
fixed installation -40C to +80C adapted to DIN VDE 0207-363-3/ The materials used in manufacture are
Nominal voltage U0/U 300/500 V DIN EN 50363-3, for better sliding abilities cadmium-free and contain no silicone
Test voltage 4000 V Core identification to DIN VDE 0293 and free from substances harmful to
Breakdown voltage min. 8000 V black cores with continuous white the wetting properties of lacquers
Insulation resistance numbering
min. 20 MOhm x km GN-YE conductor, 3 cores and above Note
Minimum bending radius in the outer layer G = with green-yellow conductor
flexing 10x cable Cores stranded in layers with optimal x = without green-yellow conductor (OZ)
fixed installation 5x cable selected lay-length 1)Change-over up to construction with
Radiation resistance Fleece separator Cu-screening, tinned, approx. 85% for
up to 100x106 cJ/kg (up to 100 Mrad) Oil resistant PVC inner sheath coverage optimisation of the useful
One layer of tinned copper wire screening1), properties are in preparation
approx. 85% coverage AWG sizes are approximate equivalent
Outer sheath of special full-polyurethane values. The actual cross-section is in mm.
to DIN VDE 0207-363-10-2/ unscreened analogue type:
DIN EN 50363-10-2 PUR-JZ-HF, confer page 167
Colour grey (RAL 7001)
with meter marking

Application
PUR-JZ-HF-YCP is a highly robust and tare and abrasion resistant cable with excellent resistance properties to mineral oils and cooling fluids, thus
making it an ideal choice for installation in most types of industrial machinery as well as in steel works and rolling mills, etc. in fact, wherever you may
need a cable to cope with especially critical situations. Easy to install, thanks to its high degree of flexibility. Its high abrasion resistance and good
flexing ability make it quick and easy to install and, with its low bending radius, ideal for use with cable trays. This screened cable is ideal for use in
data signal transmission free from interferences for measurement and control engineering technology. For applications which go beyond standard
solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially
developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection
table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22400 2 x 0,5 7,5 30,0 90,0 20 22417 2 x 0,75 7,5 39,0 106,0 19
22401 3 G 0,5 7,8 38,0 104,0 20 22418 3 G 0,75 7,8 49,0 120,0 19
22402 4 G 0,5 7,8 48,0 123,0 20 22419 4 G 0,75 8,5 60,0 150,0 19
22403 5 G 0,5 8,5 65,0 131,0 20 22420 5 G 0,75 9,1 70,0 158,0 19
22404 7 G 0,5 9,5 70,0 172,0 20 22421 7 G 0,75 10,9 95,0 205,0 19
22405 8 G 0,5 10,4 81,0 195,0 20 22422 8 G 0,75 11,5 104,0 272,0 19
22406 10 G 0,5 11,4 94,0 230,0 20 22423 10 G 0,75 13,0 110,0 290,0 19
22407 12 G 0,5 11,6 110,0 250,0 20 22424 12 G 0,75 13,2 141,0 304,0 19
22408 14 G 0,5 12,0 135,0 280,0 20 22425 14 G 0,75 13,7 163,0 380,0 19
22409 18 G 0,5 13,4 157,0 321,0 20 22426 18 G 0,75 15,2 211,0 418,0 19
22410 21 G 0,5 14,8 175,0 380,0 20 22427 21 G 0,75 16,4 274,0 485,0 19
22411 25 G 0,5 16,1 240,0 445,0 20 22428 25 G 0,75 18,2 322,0 578,0 19
22412 30 G 0,5 16,4 275,0 509,0 20 22429 30 G 0,75 18,6 414,0 630,0 19
22413 34 G 0,5 17,8 305,0 560,0 20 22430 34 G 0,75 20,0 473,0 720,0 19
22414 42 G 0,5 19,1 330,0 780,0 20 22431 42 G 0,75 21,5 583,0 780,0 19
22415 50 G 0,5 20,6 393,0 960,0 20 22432 50 G 0,75 23,7 626,0 954,0 19
22416 61 G 0,5 23,0 541,0 1050,0 20 22433 61 G 0,75 25,9 763,0 1085,0 19

Continuation

172
Cables for Drag Chains / PUR Cables for Drag Chains

PUR-JZ-HF-YCP EMC-preferred type, cable for drag chains, screened,


PUR-outer sheath, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22434 2x1 8,5 50,0 116,0 18 22470 2 x 2,5 10,9 96,0 185,0 14
22435 3G1 8,8 60,0 135,0 18 22471 3 G 2,5 11,4 150,0 278,0 14
22436 4G1 9,4 73,0 178,0 18 22472 4 G 2,5 12,2 159,0 370,0 14
22437 5G1 10,7 81,0 188,0 18 22473 5 G 2,5 13,5 195,0 412,0 14
22438
22439
22440
7G1
8G1
10 G 1
12,1
13,2
14,6
114,0
130,0
178,0
235,0
270,0
340,0
18
18
18
22474
22475
22476
7 G 2,5
12 G 2,5
14 G 2,5
16,0
19,4
20,4
240,0
390,0
480,0
470,0
738,0
870,0
14
14
14
C
22441 12 G 1 14,8 186,0 358,0 18 22477 18 G 2,5 23,0 620,0 1100,0 14
22442 14 G 1 15,6 231,0 415,0 18 22478 25 G 2,5 27,7 821,0 1512,0 14
22443 18 G 1 17,0 254,0 500,0 18 22479 2G4 13,1 135,0 235,0 12
22444 21 G 1 19,0 328,0 525,0 18 22480 3G4 13,7 178,0 350,0 12
22445 25 G 1 20,9 378,0 678,0 18 22481 4G4 15,6 222,0 460,0 12
22446 32 G 1 22,6 450,0 777,0 18 22482 5G4 16,7 328,0 550,0 12
22447 34 G 1 23,3 478,0 825,0 18 22483 7G4 19,7 360,0 700,0 12
22448 41 G 1 25,1 576,0 980,0 18 22484 3G6 16,0 250,0 525,0 10
22449 42 G 1 25,3 590,0 998,0 18 22485 4G6 17,2 305,0 700,0 10
22450 50 G 1 27,6 702,0 1160,0 18 22486 5G6 19,3 441,0 800,0 10
22451 65 G 1 30,7 913,0 1670,0 18 22487 7G6 21,6 505,0 1100,0 10
22452 2 x 1,5 9,0 64,0 141,0 16 22488 3 G 10 20,4 370,0 855,0 8
22453 3 G 1,5 9,4 84,0 164,0 16 22489 4 G 10 23,0 485,0 1140,0 8
22454 4 G 1,5 10,6 99,0 220,0 16 22490 5 G 10 25,3 610,0 1310,0 8
22455 5 G 1,5 11,4 120,0 233,0 16 22491 7 G 10 28,0 820,0 1630,0 8
22456 7 G 1,5 13,3 148,0 323,0 16 22492 4 G 16 26,2 840,0 1391,0 6
22457 8 G 1,5 14,5 191,0 369,0 16 22493 5 G 16 28,6 1050,0 1810,0 6
22458 10 G 1,5 15,9 240,0 461,0 16 22494 7 G 16 31,5 1510,0 2166,0 6
22459 12 G 1,5 16,1 274,0 481,0 16
22460 14 G 1,5 16,7 340,0 561,0 16
22461 18 G 1,5 18,4 395,0 672,0 16
22462 21 G 1,5 20,6 461,0 780,0 16
22463 25 G 1,5 22,8 533,0 927,0 16
22464 30 G 1,5 23,5 608,0 1030,0 16
22465 34 G 1,5 26,1 702,0 1180,0 16
22466 42 G 1,5 27,8 867,0 1458,0 16
22467 50 G 1,5 30,3 1033,0 1857,0 16
22468 61 G 1,5 32,7 1233,0 2250,0 16
22469 65 G 1,5 33,5 1315,0 2401,0 16

Dimensions and specifications may be changed without prior notice. (RC02)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

173
Cables for Drag Chains / PUR Cables for Drag Chains

MULTIFLEX 512-C-PUR special cable for drag chains,


halogen-free, screened, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special drag chain cables for extreme Bare copper, extra fine wire conductors, Very good oil resistant
mechanical stress in accordance to bunch stranded to DIN VDE 0295 cl.6, Guaranteed permanent application in
DIN VDE 0285-525-2-21/ col. 4, BS 6360 cl.6 and IEC 60228 cl.6 multi-shift operation under extreme high
DIN EN 50525-2-21 Core insulation special PP bending stress
Temperature range Core identification black cores with Adhesion-low
flexing -30C to +80C continuous white numbering High resistant to mechanical strain
fixed installation -40C to +80C GN-YE conductor, 3 cores and above High property of alternating bending strength
Nominal voltage U0/U 300/500 V in the outer layer Long life durabilities through low
Test voltage Cores stranded in layers with optimal friction-resistance by using the PP insulation
3000 V selected lay-length High tensile strength-, abrasion- and impact
Insulation resistance Special core wrapping over each layers and resistant at low temperature
min. 100 MOhm x km an additional fleece over outer layer Resistant to weather, ozone and UV-radiation,
Minimum bending radius TPE-inner sheath, halogen-free solvents, acids and alkalis, hydraulic liquidity
flexing 7,5x cable Wrapping with special tapes and hydrolysis
fixed installation 4x cable Tinned copper braided screening , The materials used in manufacture are
Test of alternating bending cycles approx. 85% coverage cadmium-free and contain no silicone
approx. 10 million Special core wrapping of fleece (up to 4 mm and free from substances harmful to
Radiation resistance without core wrapping over the outer layer the wetting properties of lacquers
up to 50x106 cJ/kg (up to 50 Mrad) Outer sheath of special full-polyurethane
Coupling resistance TMPU, to DIN VDE 0207-363-10-2 / Note
max. 250 Ohm/km DIN EN 50363-10-2 AWG sizes are approximate equivalent
Sheath colour grey, (RAL 7001), with a values. The actual cross-section is in mm.
matte surface G = with green-yellow conductor
with meter marking x = without green-yellow conductor (OZ)
Please note the cleanroom qualification when
ordering.
For more information see introduction
unscreened analogue type:
MULTIFLEX 512-PUR , confer page 169

Application
The special screened cables for drag chains are mainly applied for impulse transmission to prevent external interference effects and used for permanent
flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts and multi-shift operation. Those cables
are developed according to the newest state of technology improvement. These high flexible control cables with sliding abilities guaranteed an optimum
service life durabilities and also very economic by using the PP-core insulation and the PUR-outer sheath which is adhesive-free and cut-resistant.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22571 2 x 0,5 8,3 30,0 90,0 20 22577 18 G 0,5 14,7 157,0 325,0 20
22572 3 G 0,5 8,5 38,0 105,0 20 22578 20 G 0,5 15,4 167,0 350,0 20
22573 4 G 0,5 9,0 50,0 124,0 20 22579 25 G 0,5 17,1 240,0 450,0 20
22574 5 G 0,5 9,7 65,0 132,0 20 22580 30 G 0,5 17,9 273,0 510,0 20
22575 7 G 0,5 11,1 70,0 175,0 20 22581 36 G 0,5 19,2 306,0 580,0 20
22576 12 G 0,5 12,7 100,0 250,0 20

Continuation

174
Cables for Drag Chains / PUR Cables for Drag Chains

MULTIFLEX 512-C-PUR special cable for drag chains,


halogen-free, screened, EMC-preferred type, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22582 2 x 0,75 8,8 39,0 110,0 19 22609 12 G 1,5 17,4 279,0 481,0 16
22583 3 G 0,75 9,3 49,0 120,0 19 22610 18 G 1,5 19,9 393,0 675,0 16
22584 4 G 0,75 9,7 60,0 148,0 19 22611 25 G 1,5 23,7 584,0 927,0 16
22585 5 G 0,75 10,5 70,0 160,0 19 22612 30 G 1,5 24,6 607,0 1025,0 16
22586
22587
22588
7 G 0,75
12 G 0,75
18 G 0,75
11,9
14,2
16,3
95,0
140,0
220,0
205,0
308,0
420,0
19
19
19
22613
22887
22888
36 G 1,5
42 G 1,5
50 G 1,5
26,4
28,4
31,2
702,0
829,0
1025,0
1210,0
1441,0
1709,0
16
16
16
C
22589 20 G 0,75 16,9 249,0 450,0 19 22889 61 G 1,5 34,2 1190,0 2025,0 16
22590 25 G 0,75 19,2 313,0 579,0 19 22614 2 x 2,5 11,9 104,0 198,0 14
22591 30 G 0,75 19,7 470,0 630,0 19 22615 3 G 2,5 12,6 140,0 284,0 14
22592 36 G 0,75 21,2 500,0 745,0 19 22616 4 G 2,5 13,6 164,0 378,0 14
22593 2x1 9,7 50,0 120,0 18 22617 5 G 2,5 14,7 190,0 423,0 14
22594 3G1 10,0 60,0 135,0 18 22618 7 G 2,5 17,4 236,0 486,0 14
22595 4G1 10,8 73,0 173,0 18 22619 12 G 2,5 20,9 390,0 756,0 14
22596 5G1 11,7 81,0 187,0 18 22620 18 G 2,5 24,2 607,0 1127,0 14
22597 7G1 13,4 114,0 240,0 18 22621 20 G 2,5 25,6 661,0 1210,0 14
22598 12 G 1 16,0 186,0 360,0 18 22622 25 G 2,5 29,1 796,0 1530,0 14
22599 18 G 1 18,5 254,0 498,0 18 22623 4G4 16,8 222,0 448,0 12
22600 20 G 1 19,4 322,0 568,0 18 22624 5G4 18,4 328,0 533,0 12
22601 25 G 1 21,7 377,0 670,0 18 22625 7G4 21,6 360,0 678,0 12
22602 30 G 1 22,5 429,0 774,0 18 22626 4G6 18,1 305,0 636,0 10
22603 36 G 1 24,3 516,0 895,0 18 22627 5G6 19,6 441,0 772,0 10
22884 41 G 1 26,1 610,0 1032,0 18 22628 7G6 23,2 505,0 1028,0 10
22885 50 G 1 28,4 690,0 1160,0 18 22629 4 G 10 22,5 485,0 1052,0 8
22886 65 G 1 32,2 852,0 1660,0 18 22630 5 G 10 24,7 610,0 1096,0 8
22604 2 x 1,5 10,2 64,0 145,0 16 22631 7 G 10 29,3 820,0 1530,0 8
22605 3 G 1,5 11,0 84,0 168,0 16 22632 4 G 16 25,7 840,0 1386,0 6
22606 4 G 1,5 11,6 99,0 217,0 16 22633 5 G 16 28,2 1050,0 1759,0 6
22607 5 G 1,5 12,6 129,0 235,0 16 22634 7 G 16 33,6 1510,0 2087,0 6
22608 7 G 1,5 14,5 148,0 325,0 16

Dimensions and specifications may be changed without prior notice. (RC02)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

175
Cables for Drag Chains / PUR Cables for Drag Chains

MULTISPEED 500-C-PUR safety against high bending in drag


chain systems, low torsion, halogen-free, EMC-preferred type, halogen-free, meter marking

Technical data Cable structure Properties


Special drag chain cables for high mechanical Bare copper, fine wire conductors, Low adhesion
stress adapted to DIN VDE 0285-525-2-51/ Unilay with short pitch length High property of alternating bending strength
DIN EN 50525-2-51 and Core insulation of special PP High resistant to mechanical strain
DIN VDE 0285-525-2-21/DIN EN Core identification black cores with Long life durabilitys due to low
50525-2-21 continuous white numbering friction-resistance
Temperature range GN-YE conductor, 3 cores and above High tensile strength, abrasion- and impact
flexing -30C to +80C Stranding: resistance at low temperature
fixed installation -40C to +80C <7 cores: cores stranded in a layer with Tear resistance
Nominal voltage U0/U 300/500 V optimal lay-length around a filler as per High stability and oil resistance
Test voltage 3000 V construction Better chemical resistance
Insulation resistance 7 cores: cores stranded with optimal UV and ozone resistance
min. 100 MOhm x km lay-length to bunch-construction with low Higher economical solution
Minimum bending radius torsion strength, optimal selected short Reduced , results low weight of moving
flexing 7,5x cable lay-length around a filler materials
fixed installation 4x cable Special-TPE inner sheath, extruded as filler The materials used in manufacture are
Coupling resistant with pressure, grey RAL 7001 cadmium-free and contain no silicone
max. 250 Ohm/km Tinned copper braided screen, and free from substances harmful to
Radiation resistance coverage 85% max., with optimal pitch the wetting properties of lacquers
up to 100x106 cJ/kg (up to 100 Mrad) Fleece separator, ensure good dismantling
ability Note
Outer sheath of special PUR AWG sizes are approximate equivalent
Sheath colour black (RAL 9005) values. The actual cross-section is in mm.
with meter marking G = with green-yellow conductor
x = without green-yellow conductor (OZ)
unscreened analogue type:
MULTISPEED 500-PUR, confer page 171

Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and wet rooms
and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are installed
there, where the problems appear for the application in permanent stresses e. g. in energy drag chains. These cables are installed everywhere, where
high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary. These screened cables are particularly suitable for the
interference-free transmission in instrumentation and control engineering applications. For applications which go beyond standard solutions we
recommend for our especially developed enquiry sheet for energy guiding systems.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24156 2 x 0,5 6,4 30,0 90,0 20 24173 2x1 7,1 50,0 120,0 18
24157 3 G 0,5 6,7 36,0 104,0 20 24174 3G1 7,6 59,0 140,0 18
24158 4 G 0,5 7,2 42,0 118,0 20 24175 4G1 8,1 70,0 167,0 18
24159 5 G 0,5 7,6 48,0 148,0 20 24176 5G1 8,9 84,0 201,0 18
24160 7 G 0,5 11,4 64,0 184,0 20 24177 7G1 13,6 106,0 256,0 18
24161 9 G 0,5 11,4 80,0 219,0 20 24178 12 G 1 14,6 174,0 417,0 18
24162 12 G 0,5 12,4 105,0 276,0 20 24179 18 G 1 18,4 240,0 557,0 18
24163 18 G 0,5 14,7 137,0 378,0 20 24180 25 G 1 21,0 332,0 766,0 18
24164 25 G 0,5 17,1 210,0 547,0 20 24181 3 G 1,5 8,4 75,0 170,0 16
24165 2 x 0,75 6,8 40,0 100,0 19 24182 4 G 1,5 9,1 90,0 204,0 16
24166 3 G 0,75 7,3 48,0 117,0 19 24183 5 G 1,5 10,2 108,0 236,0 16
24167 4 G 0,75 7,8 55,0 143,0 19 24184 7 G 1,5 15,7 157,0 309,0 16
24168 5 G 0,75 8,3 66,0 167,0 19 24185 12 G 1,5 17,4 240,0 509,0 16
24169 7 G 0,75 12,7 85,0 229,0 19 24186 18 G 1,5 21,3 355,0 718,0 16
24170 12 G 0,75 13,7 135,0 319,0 19 24187 25 G 1,5 24,3 448,0 944,0 16
24171 18 G 0,75 17,1 190,0 492,0 19 24188 4 G 2,5 11,2 134,0 280,0 14
24172 25 G 0,75 19,5 275,0 659,0 19 24189 5 G 2,5 12,2 175,0 346,0 14
24190 7 G 2,5 19,7 229,0 410,0 14

Dimensions and specifications may be changed without prior notice. (RC02)

176
Cables for Drag Chains / TPE Cables for Drag Chains

MULTISPEED 500-TPE high flexible, safety against high


bending in drag chain systems, low torsion, halogen-free, meter marking

Technical data Cable structure Properties


Special drag chain cables for high Tinned copper, fine wire conductors, Unilay Microbe-resistance - TPE
mechanical stress adapted to with short pitch length Halogen-free
DIN VDE 0285-525-2-51/ Core insulation of special PP Low adhesion
DIN EN 50525-2-51 Core identification black cores with High property of alternating bending strength
Temperature range continuous white numbering High resistant to mechanical strain
flexing -30C to +80C GN-YE conductor, 3 cores and above Long life durabilitys due to low
fixed installation -40C to +80C Stranding: friction-resistance
Nominal voltage U0/U 300/500 V <7 cores: cores stranded in a layer with High tensile strength, abrasion- and impact
Test voltage 3000 V optimal lay-length around a filler as per resistance at low temperature
Insulation resistance construction Use in multi-shift operations under extremely
min. 100 MOhm x km 7 cores: cores stranded with optimal high continuous bending loads
Minimum bending radius lay-length to bunch-construction with low Abrasion resistance
flexing 5x cable torsion strength, optimal selected short Tear resistance
fixed installation 3x cable lay-length around a filler High stability
Radiation resistance Outer sheath of special TPE-O Oil resistance
up to 100x106 cJ/kg (up to 100 Mrad) extruded as filler with pressure Better chemical resistance
Sheath colour ocean blue (RAL 5020) UV and ozone resistance
with meter marking Higher economical solution
TPE: The selected tinned copper wire Reduced , results low weight of moving
conductor permits the installation in materials
aggressive environments as well as hydrogen The materials used in manufacture are
sulfide, ammonia and sulfur dioxide cadmium-free and contain no silicone
and free from substances harmful to
the wetting properties of lacquers

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified" when
ordering.
screened analogue type:
MULTISPEED 500-C-TPE,
confer page 179

Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and wet rooms
and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are installed
there, where the problems appear for the application in permanent stresses e. g. in energy drag chains, industry robotics, production lines, automatic
control systems and permanent movable machinery parts for multi-shift operation. For applications which go beyond standard solutions we recommend
for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24191 2 x 0,5 4,7 9,6 42,0 20 24199 2 x 0,75 5,0 14,4 47,0 19
24192 3 G 0,5 5,0 14,4 49,0 20 24200 3 G 0,75 5,2 21,6 55,0 19
24193 4 G 0,5 5,4 19,0 63,0 20 24201 4 G 0,75 6,0 29,0 70,0 19
24194 5 G 0,5 5,8 24,0 70,0 20 24202 5 G 0,75 6,5 36,0 74,0 19
24195 7 G 0,5 8,9 33,6 90,0 20 24203 7 G 0,75 10,3 50,0 95,0 19
24196 12 G 0,5 9,7 58,0 134,0 20 24204 12 G 0,75 11,0 86,0 174,0 19
24197 18 G 0,5 11,8 86,0 209,0 20 24205 18 G 0,75 13,9 130,0 261,0 19
24198 25 G 0,5 13,9 120,0 270,0 20 24206 25 G 0,75 15,9 180,0 290,0 19
24207 36 G 0,75 19,6 260,0 419,0 19
24208 42 G 0,75 21,5 302,0 614,0 19

Continuation

177
Cables for Drag Chains / TPE Cables for Drag Chains

MULTISPEED 500-TPE high flexible, safety against high


bending in drag chain systems, low torsion, halogen-free, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24209 2x1 5,2 19,2 50,0 18 24224 4 G 2,5 8,8 96,0 179,0 14
24210 3G1 5,8 29,0 60,0 18 24225 5 G 2,5 9,8 120,0 230,0 14
24211 4G1 6,3 38,0 74,0 18 24226 7 G 2,5 16,1 168,0 294,0 14
24212 5G1 6,9 48,0 86,0 18 24227 12 G 2,5 17,8 288,0 510,0 14
24213 7G1 11,1 67,0 114,0 18 24228 18 G 2,5 21,8 432,0 722,0 14
24214 12 G 1 12,0 115,0 210,0 18 24229 25 G 2,5 24,4 600,0 950,0 14
24215 18 G 1 14,8 173,0 291,0 18 24230 4G4 10,3 154,0 197,0 12
24216 25 G 1 17,2 240,0 380,0 18 24231 4G6 11,9 231,0 320,0 10
24043 41 G 1 22,0 394,0 510,0 18 24232 5G6 13,4 289,0 394,0 10
24217 3 G 1,5 6,6 43,0 84,0 16 24233 4 G 10 14,7 387,0 520,0 8
24218 4 G 1,5 7,2 58,0 108,0 16 24234 4 G 16 20,0 517,0 784,0 6
24219 5 G 1,5 7,8 72,0 126,0 16 24235 4 G 35 24,9 1344,0 1711,0 2
24220 7 G 1,5 13,0 101,0 169,0 16
24221 12 G 1,5 14,2 173,0 299,0 16
24222 18 G 1,5 17,5 259,0 460,0 16
24223 25 G 1,5 20,1 360,0 640,0 16

Dimensions and specifications may be changed without prior notice. (RC02)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

178
Cables for Drag Chains / TPE Cables for Drag Chains

MULTISPEED 500-C-TPE safety against high bending in


drag chain systems, low torsion, halogen-free, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special drag chain cables for high Tinned copper, fine wire conductors, Microbe-resistance - TPE
mechanical stress adapted to Unilay with short pitch length High property of alternating bending strength
DIN VDE 0285-525-2-51 / Core insulation of special PP Long life durabilitys due to low
DIN EN 50525-2-51 Core identification black cores with friction-resistance
Temperature range continuous white numbering High tensile strength, abrasion- and impact
flexing -30C to +80C GN-YE conductor, 3 cores and above resistance at low temperature
fixed installation -40C to +80C Stranding: Low adhesion, oil resistence
Nominal voltage U0/U 300/500 V <7 cores: cores stranded in a layer with Tear resistance
Test voltage 3000 V optimal lay-length around a filler as per Better chemical resistance
Insulation resistance construction UV and ozone resistance
min. 100 MOhm x km 7 cores: cores stranded with optimal Reduced , results low weight of moving
Minimum bending radius lay-length to bunch-construction with low materials
flexing 5x cable torsion strength, optimal selected short The materials used in manufacture are
fixed installation 3x cable lay-length around a filler cadmium-free and contain no silicone
Coupling resistance Inner sheath of special-TPE , extruded as filler and free from substances harmful to
max. 250 Ohm x km with pressure, natural colour the wetting properties of lacquers
Radiation resistance Screen of Cu braid tinned,
up to 100x106 cJ/kg (up to 100 Mrad) coverage 85% max., with optimal pitch Note
Fleece separator, ensure good dismantling AWG sizes are approximate equivalent
ability values. The actual cross-section is in mm.
Outer sheath of special-TPE-O G = with green-yellow conductor
extruded as filler with pressure x = without green-yellow conductor (OZ)
Sheath colour ocean blue (RAL 5020) Please note the cleanroom qualification when
with meter marking ordering.
TPE: The selected tinned copper wire For more information, see introduction
conductor permits the installation in unscreened analogue type:
aggressive environments as well as hydrogen MULTISPEED 500-TPE, confer page 177
sulfide, ammonia and sulfur dioxide

Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and wet rooms
and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are installed
there, where the problems appear for the application in permanent stresses e. g. in energy drag chains. These cables are installed everywhere, where
high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24236 2 x 0,5 6,5 30,0 85,0 20 24255 4G1 8,1 70,0 160,0 18
24237 3 G 0,5 6,7 36,0 99,0 20 24256 5G1 8,9 84,0 195,0 18
24238 4 G 0,5 7,2 42,0 107,0 20 24257 7G1 13,6 106,0 247,0 18
24239 5 G 0,5 7,6 48,0 140,0 20 24258 12 G 1 14,8 174,0 411,0 18
24240 7 G 0,5 11,4 64,0 176,0 20 24259 18 G 1 18,4 240,0 547,0 18
24241 10 G 0,5 11,4 80,0 204,0 20 24260 25 G 1 21,0 332,0 754,0 18
24242 12 G 0,5 12,4 105,0 261,0 20 24261 3 G 1,5 8,4 75,0 160,0 16
24243 18 G 0,5 14,7 137,0 360,0 20 24262 4 G 1,5 9,2 90,0 194,0 16
24244 25 G 0,5 17,1 320,0 530,0 20 24263 5 G 1,5 10,2 108,0 220,0 16
24245 2 x 0,75 7,0 40,0 97,0 19 24264 7 G 1,5 15,7 157,0 294,0 16
24246 3 G 0,75 7,3 48,0 110,0 19 24265 12 G 1,5 17,4 240,0 490,0 16
24247 4 G 0,75 7,8 55,0 139,0 19 24266 18 G 1,5 21,3 355,0 704,0 16
24248 5 G 0,75 8,3 66,0 160,0 19 24267 25 G 1,5 24,3 448,0 930,0 16
24249 7 G 0,75 12,7 85,0 219,0 19 24268 4 G 2,5 11,2 134,0 260,0 14
24250 12 G 0,75 13,7 135,0 307,0 19 24269 5 G 2,5 12,2 175,0 330,0 14
24251 18 G 0,75 17,1 190,0 490,0 19 24270 7 G 2,5 19,5 229,0 406,0 14
24252 25 G 0,75 19,5 275,0 640,0 19 24271 12 G 2,5 21,7 390,0 990,0 14
24253 2x1 7,3 50,0 115,0 18 24272 4G4 13,6 194,0 355,0 12
24254 3G1 7,6 59,0 131,0 18

Dimensions and specifications may be changed without prior notice. (RC02)

179
BIO-OIL & MICROBE-RESISTANT CABLES
DRAG CHAIN CABLES
Cables for Drag Chains / Bio-Oil and microbial resistant Cables for Drag Chains

BIOFLEX-500-JZ-HF Bio-fuel resistant, abrasion resistant, recyclable


environment friendly, bio-oil resistant , cable for drag chains, meter marking
1)

Technical data Cable structure Properties


Bio-oil resistant, abrasion resistant special Bare copper, extra fine wire conductors, Resistant to
high flexible control cable adapted to bunch stranded to DIN VDE 0295 cl.6, Bio-fuel (diesel and petrol), highly resistant
DIN VDE 0285-525-1/DIN EN 50525-1 BS 6360 cl.6 and IEC 60228 cl.6 to biologically decomposable oils, Oxygene,
Temperature range Core insulation of special polymer with Ozone, Hydrolysis and Microbes
flexing -20C to +80C improved sliding ability Low adhesion
fixed installation -40C to +80C Core identification to DIN VDE 0293
Nominal voltage U0/U 300/500 V black cores with continuous white Note
Test voltage 3000 V numbering G = with green-yellow conductor
Insulation resistance GN-YE conductor, 3 cores and above x = without green-yellow conductor (OZ)
min. 20 MOhm x km in the outer layer AWG sizes are approximate equivalent
Minimum bending radius Cores stranded in layers with optimal selected values. The actual cross-section is in mm.
flexing 10x cable lay-length unscreened analogue type:
fixed installation 4x cable Wrapping with fleece BIOFLEX-500-JZ-HF-C, confer page 182
Radiation resistance Outer sheath of special polymer compound
up to 100x106 cJ/kg (up to 100 Mrad) Sheath colour dark green
with meter marking

Application
HELUKABEL BIOFLEX-500-JZ-HF is an extremely robust and high flexible control cable with high abrasion and tear resistant properties. Due to its
high resistance to Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as in
the steel industry for difficult and problem areas. Suitable in combination with cable trays in dry, moist and wet rooms and outdoor installation. The
high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying. 1) For the critical applications we advise for consultation.
For applications which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems. Before
installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25761 2 x 0,5 5,4 9,6 45,0 20 25796 10 G 1,5 13,4 144,0 344,0 16
25762 3 G 0,5 5,9 14,4 56,0 20 25797 12 G 1,5 13,4 173,0 391,0 16
25763 4 G 0,5 6,3 19,1 69,0 20 25798 14 G 1,5 14,3 202,0 457,0 16
25764 5 G 0,5 6,9 24,0 92,0 20 25799 18 G 1,5 16,0 259,0 589,0 16
25765 7 G 0,5 7,8 33,6 126,0 20 25800 25 G 1,5 19,5 360,0 801,0 16
25766 10 G 0,5 9,6 48,0 158,0 20 25801 2 x 2,5 8,6 48,0 128,0 14
25767 12 G 0,5 10,3 58,0 176,0 20 25802 3 G 2,5 9,3 72,0 160,0 14
25768 14 G 0,5 10,3 67,0 212,0 20 25803 4 G 2,5 10,3 96,0 200,0 14
25769 18 G 0,5 11,5 86,4 283,0 20 25804 5 G 2,5 11,5 120,0 268,0 14
25770 25 G 0,5 13,6 120,0 330,0 20 25805 7 G 2,5 13,4 168,0 357,0 14
25771 2 x 0,75 5,9 14,4 57,0 19 25806 12 G 2,5 17,0 288,0 571,0 14
25772 3 G 0,75 6,2 21,6 72,0 19 25807 14 G 2,5 18,5 336,0 612,0 14
25773 4 G 0,75 6,7 29,0 97,0 19 25808 18 G 2,5 20,0 432,0 800,0 14
25774 5 G 0,75 7,3 36,0 119,0 19 25809 25 G 2,5 29,6 600,0 1100,0 14
25775 7 G 0,75 8,7 50,0 165,0 19 25810 2x4 10,4 77,0 190,0 12
25776 10 G 0,75 10,5 72,0 214,0 19 25811 3G4 11,2 115,0 250,0 12
25777 12 G 0,75 11,0 86,0 247,0 19 25812 4G4 12,5 154,0 320,0 12
25778 14 G 0,75 11,4 101,0 283,0 19 25813 5G4 13,8 192,0 400,0 12
25779 18 G 0,75 12,6 130,0 356,0 19 25814 3G6 13,0 173,0 350,0 10
25780 25 G 0,75 15,2 180,0 698,0 19 25815 4G6 14,7 230,0 500,0 10
25781 2x1 6,6 19,0 64,0 18 25816 5G6 16,0 288,0 580,0 10
25782 3G1 7,0 29,0 83,0 18 25817 3 G 10 17,4 288,0 660,0 8
25783 4G1 7,6 38,5 113,0 18 25819 5 G 10 21,3 480,0 990,0 8
25784 5G1 8,2 48,0 137,0 18 25820 4 G 16 23,2 614,0 1200,0 6
25785 7G1 9,6 67,0 191,0 18 25821 4 G 25 34,0 960,0 1700,0 4
25786 10 G 1 11,6 96,0 251,0 18 25822 4 G 35 37,0 1344,0 2300,0 2
25787 12 G 1 12,0 115,0 294,0 18 25823 4 G 50 44,0 1920,0 2500,0 1
25788 14 G 1 13,0 134,0 337,0 18 25824 4 G 70 53,0 2688,0 4600,0 2/0
25789 18 G 1 14,5 173,0 420,0 18 25825 4 G 95 59,0 3648,0 6400,0 3/0
25790 25 G 1 17,6 240,0 600,0 18
25791 2 x 1,5 7,1 29,0 90,0 16
25792 3 G 1,5 7,5 43,0 117,0 16
25793 4 G 1,5 8,2 58,0 147,0 16
25794 5 G 1,5 9,0 72,0 181,0 16
25795 7 G 1,5 10,8 101,0 274,0 16

Dimensions and specifications may be changed without prior notice. (RC03)

181
Cables for Drag Chains / Bio-Oil and microbial resistant Cables for Drag Chains

BIOFLEX-500-JZ-HF-C Biofuel-resistant, abrasion-resistant, recyclable,


environmentally friendly, drag-chain cable, bio-oil resistant 1), meter marking

Technical data Cable structure Properties


Bio-oil resistant, abrasion resistant special Bare copper, extra fine wire conductors, Resistant to
high flexible control cable adapted to bunch stranded to DIN VDE 0295 cl.6, Bio-fuel (diesel and petrol), highly resistant
DIN VDE 0285-525-1 / DIN EN 50525-1 BS 6360 cl.6 and IEC 60228 cl.6 to biologically decomposable oils, Oxygene,
Temperature range Core insulation of special polymer with Ozone, Hydrolysis and Microbes
flexing -20C to +80C improved sliding ability Low adhesion
fixed installation -40C to +80C Core identification to DIN VDE 0293
Nominal voltage U0/U 300/500 V black cores with continuous white Note
Test voltage 3000 V numbering G = with green-yellow conductor
Insulation resistance GN-YE conductor, 3 cores and above x = without green-yellow conductor (OZ)
min. 20 MOhm x km in the outer layer AWG sizes are approximate equivalent
Minimum bending radius Cores stranded in layers with optimal selected values. The actual cross-section is in mm.
flexing 15x cable lay-length unsreened analogue type:
fixed installation 4x cable Wrapping with fleece BIOFLEX-500-JZ-HF, confer page 181
Coupling resistance Special inner sheath
max. 250 Ohm/km Copper braided screening
Radiation resistance approx. 85% coverage
up to 100x106 cJ/kg (up to 100 Mrad) Wrapping with fleece guarantees a good
dismantling
Outer sheath of special polymer compound
Sheath colour dark green
with meter marking

Application
HELUKABEL BIOFLEX-500-JZ-HF-C is an extremely robust and high flexible control cable with high abrasion and tear resistant properties. Due to
its high resistance to Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as
in the steel industry for difficult and problem areas. Suitable in combination with cable trays in dry, moist and wet rooms and outdoor installation. The
high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying. These screened cables are particularly suitable for the
interference-free transmission in instrumentation and control engineering applications (electromagnetic compatibillity). For the critical applications
we advise for consultation. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with
extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in
cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25826 2 x 0,5 7,5 47,0 90,0 20 25849 5G1 11,8 99,0 188,0 18
25827 3 G 0,5 7,8 52,0 104,0 20 25850 7G1 12,7 125,0 235,0 18
25828 4 G 0,5 8,2 55,0 123,0 20 25851 10 G 1 14,6 178,0 340,0 18
25829 5 G 0,5 9,9 65,0 131,0 20 25852 12 G 1 15,5 186,0 358,0 18
25830 7 G 0,5 10,0 84,0 172,0 20 25853 14 G 1 16,7 250,0 415,0 18
25831 10 G 0,5 11,3 115,0 230,0 20 25854 18 G 1 18,0 280,0 500,0 18
25832 12 G 0,5 12,5 117,0 250,0 20 25855 25 G 1 21,0 378,0 678,0 18
25833 14 G 0,5 13,2 148,0 280,0 20 25856 2 x 1,5 10,5 79,0 141,0 16
25834 18 G 0,5 14,5 157,0 321,0 20 25857 3 G 1,5 10,8 94,0 164,0 16
25835 25 G 0,5 16,8 227,0 445,0 20 25858 4 G 1,5 11,5 113,0 220,0 16
25836 2 x 0,75 8,3 53,0 106,0 19 25859 5 G 1,5 12,5 129,0 233,0 16
25837 3 G 0,75 8,5 62,0 120,0 19 25860 7 G 1,5 13,2 170,0 323,0 16
25838 4 G 0,75 9,5 77,0 150,0 19 25861 8 G 1,5 14,4 226,0 369,0 16
25839 5 G 0,75 10,8 86,0 158,0 19 25862 10 G 1,5 14,9 258,0 461,0 16
25840 7 G 0,75 11,5 107,0 205,0 19 25863 12 G 1,5 16,2 280,0 481,0 16
25841 10 G 0,75 13,1 148,0 290,0 19 25864 14 G 1,5 18,1 340,0 561,0 16
25842 12 G 0,75 14,0 156,0 304,0 19 25865 18 G 1,5 20,3 395,0 672,0 16
25843 14 G 0,75 15,3 214,0 380,0 19 25866 21 G 1,5 21,7 461,0 780,0 16
25844 18 G 0,75 17,3 235,0 418,0 19 25867 25 G 1,5 23,1 533,0 927,0 16
25845 25 G 0,75 18,7 313,0 578,0 19 25868 2 x 2,5 11,8 96,0 185,0 14
25846 2x1 10,0 60,0 116,0 18 25869 3 G 2,5 13,0 150,0 278,0 14
25847 3G1 10,2 70,0 135,0 18 25870 4 G 2,5 14,0 174,0 370,0 14
25848 4G1 11,0 86,0 178,0 18 25871 5 G 2,5 15,1 200,0 412,0 14

Continuation

182
Cables for Drag Chains / Bio-Oil and microbial resistant Cables for Drag Chains

BIOFLEX-500-JZ-HF-C Biofuel-resistant, abrasion-resistant, recyclable,


environmentally friendly, drag-chain cable, bio-oil resistant 1), meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25872 7 G 2,5 16,2 240,0 470,0 14 25881 3G6 19,5 250,0 525,0 10
25873 12 G 2,5 21,0 410,0 738,0 14 25882 4G6 21,0 305,0 700,0 10
25874 14 G 2,5 23,4 480,0 870,0 14 25883 5G6 23,0 441,0 800,0 10
25875 18 G 2,5 25,7 620,0 1100,0 14 25884 3 G 10 18,8 370,0 855,0 8
25876
25877
25878
25 G 2,5
2x4
3G4
31,0
13,4
15,8
821,0
135,0
178,0
1512,0
235,0
350,0
14
12
12
25885
25886
25887
4 G 10
5 G 10
4 G 16
25,0
26,4
28,0
485,0
610,0
840,0
1140,0
1310,0
1391,0
8
8
6
C
25879 4G4 17,3 222,0 460,0 12
25880 5G4 19,0 328,0 550,0 12

Dimensions and specifications may be changed without prior notice. (RC03)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

183
Cables for Drag Chains / microbial resistant Cables for Drag Chains

KOMPOSPEED JZ-HF-500 halogen-free, microbes resistant,


cable for drag chains, meter marking

Technical data Cable structure Properties


Microbes resistant, halogen-free special Tinned copper, extra fine wire conductors, Resistant to
control cable adapted to bunch stranded to DIN VDE 0295 cl.6, UV-radiation
DIN VDE 0285-525-2-51/ BS 6360 cl.6 and IEC 60228 cl.6 Oxygene
DIN EN 50525-2-51 Core insulation of special thermoplastic Ozone
Temperature range polymer with improved sliding ability Microbes
flexing -30C to +90C Core identification to DIN VDE 0293 Hydrofluoric acid
fixed installation -40C to +100C black cores with continuous white Hydrochloric acid
Nominal voltage U0/U 300/500 V numbering and diluted sulfuric acid
Test voltage 3000 V GN-YE conductor, 3 cores and above Low adhesion
Isulation resistance in the outer layer The materials used in manufacture are
min. 20 MOhm x km Cores stranded in layers with optimal selected cadmium-free and contain no silicone
Minimum bending radius lay-length and free from substances harmful to
flexing 7,5x cable Wrapping with fleece over the stranded layers the wetting properties of lacquers
Radiation resistance Outer sheath of special
up to 100x106 cJ/kg (up to 100 Mrad) thermoplastic polymer Note
Sheath colour black (RAL 9005) G = with green-yellow conductor
with meter marking x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
HELUKABEL KOMPOSPEED JZ-HF-500 control cable is significant due to its resistance against microbes. This cable is specially installed in rubbish,
sewage-treatment plants, composting works, animal stalls and greenhouses. Suitable for installation for flexible use for medium mechanical, stresses
with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside. The high flexibility of this cable type
makes it quick and easy to install. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors
with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation
in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
26307 2 x 0,5 5,0 9,6 42,0 20 26331 2 x 1,5 6,4 29,0 88,0 16
26308 3 G 0,5 5,3 14,4 51,0 20 26332 3 G 1,5 6,8 43,0 104,0 16
26309 4 G 0,5 5,7 19,1 62,0 20 26333 4 G 1,5 7,4 58,0 137,0 16
26310 5 G 0,5 6,4 24,0 88,0 20 26334 5 G 1,5 8,3 72,0 171,0 16
26311 7 G 0,5 7,5 33,6 119,0 20 26335 7 G 1,5 9,9 101,0 264,0 16
26312 12 G 0,5 9,2 58,0 166,0 20 26336 12 G 1,5 12,1 173,0 381,0 16
26313 18 G 0,5 11,1 86,4 273,0 20 26337 18 G 1,5 14,5 259,0 579,0 16
26314 25 G 0,5 13,4 120,0 330,0 20 26338 25 G 1,5 17,8 360,0 789,0 16
26315 2 x 0,75 5,4 14,4 53,0 19 26339 2 x 2,5 7,7 48,0 118,0 14
26316 3 G 0,75 5,7 21,6 70,0 19 26340 3 G 2,5 8,4 72,0 172,0 14
26317 4 G 0,75 6,4 29,0 92,0 19 26341 4 G 2,5 9,1 96,0 197,0 14
26318 5 G 0,75 7,0 36,0 116,0 19 26342 5 G 2,5 10,2 120,0 258,0 14
26319 7 G 0,75 8,3 50,0 159,0 19 26343 7 G 2,5 12,2 168,0 347,0 14
26320 12 G 0,75 10,2 86,0 241,0 19 26344 12 G 2,5 15,2 288,0 561,0 14
26321 18 G 0,75 12,1 130,0 346,0 19 26345 18 G 2,5 18,1 432,0 791,0 14
26322 25 G 0,75 14,9 180,0 681,0 19 26346 25 G 2,5 22,5 600,0 1090,0 14
26323 2x1 5,7 19,2 60,0 18
26324 3G1 6,0 29,0 79,0 18
26325 4G1 6,8 38,5 107,0 18
26326 5G1 7,4 48,0 127,0 18
26327 7G1 8,8 67,0 181,0 18
26328 12 G 1 10,8 115,0 284,0 18
26329 18 G 1 13,0 173,0 397,0 18
26330 25 G 1 15,8 240,0 491,0 18

Dimensions and specifications may be changed without prior notice. (RC03)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

184
Cables for Drag Chains / microbial resistant Cables for Drag Chains

KOMPOSPEED JZ-HF-500-C halogen-free, microbes resistant,


Cu-screened, EMC-preferred type, cable for drag chains, meter marking

Technical data Cable structure Properties


Screened microbes resistant, halogen-free Tinned copper, extra fine wire conductors, Resistant to
special control cable in adapted to bunch stranded to DIN VDE 0295 cl.6, UV-radiation
DIN VDE 0285-525-2-51/ BS 6360 cl.6 and IEC 60228 cl.6 Oxygene
DIN EN 50525-2-51 Core insulation of Special thermoplastic Ozone
Temperature range polymer with improved sliding ability Microbes
flexing -30C to +90C Core identification to DIN VDE 0293 Hydrofluoric acid
fixed installation -40C to +100C black cores with continuous white Hydrochloric acid
Nominal voltage U0/U 300/500 V numbering and diluted sulfuric acid
Test voltage GN-YE conductor, 3 cores and above Low adhesion
core/core 4000 V in the outer layer The materials used in manufacture are
core/screen 2000 V Cores stranded in layers with optimal selected cadmium-free and contain no silicone
Insulation resistance lay-length and free from substances harmful to
min. 20 MOhm x km Wrapping with fleece the wetting properties of lacquers
Minimum bending radius Inner-sheath with special thermoplastic
flexing 7,5x cable polymer Note
Coupling resistance Screen of tinned copper braid, G = with green-yellow conductor
max. 250 Ohm/km coverage approx. 85% x = without green-yellow conductor (OZ)
Radiation resistance Wrapping of fleece guarantees a good AWG sizes are approximate equivalent
up to 100x106 cJ/kg (up to 100 Mrad) dismantling values. The actual cross-section is in mm.
Outer sheath of special
thermoplastic polymer
Sheath colour black (RAL 9005)
with meter marking

Application
HELUKABEL KOMPOSPEED JZ-HF-500-C control cable is significant due to its resistance against microbes. This cable is specially installed in rubbish,
sewage-treatment plants, composting works, animal stalls and greenhouses. The inner sheaths of those cables raise the mechanical stress. For medium
mechanical, stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside. This screened
cable is ideal for use in data signal transmission free from interferences for measurement and control engineering technology. For applications which
go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
26347 2 x 0,5 6,9 47,0 90,0 20 26367 5G1 9,5 99,0 179,0 18
26348 3 G 0,5 7,2 52,0 101,0 20 26368 7G1 10,9 125,0 229,0 18
26349 4 G 0,5 7,8 55,0 119,0 20 26369 12 G 1 13,1 186,0 348,0 18
26350 5 G 0,5 8,3 65,0 121,0 20 26370 18 G 1 15,4 280,0 498,0 18
26351 6 G 0,5 9,1 70,0 144,0 20 26371 25 G 1 18,6 378,0 669,0 18
26352 7 G 0,5 9,6 84,0 169,0 20 26372 2 x 1,5 8,3 79,0 141,0 16
26353 12 G 0,5 11,3 117,0 250,0 20 26373 3 G 1,5 8,7 94,0 162,0 16
26354 18 G 0,5 13,5 157,0 321,0 20 26374 4 G 1,5 9,5 113,0 210,0 16
26355 25 G 0,5 15,8 227,0 445,0 20 26375 5 G 1,5 10,2 129,0 233,0 16
26356 2 x 0,75 7,3 53,0 106,0 19 26376 7 G 1,5 12,2 170,0 317,0 16
26357 3 G 0,75 7,8 62,0 116,0 19 26377 12 G 1,5 14,5 280,0 471,0 16
26358 4 G 0,75 8,3 77,0 140,0 19 26378 18 G 1,5 16,9 395,0 664,0 16
26359 5 G 0,75 9,1 86,0 148,0 19 26379 25 G 1,5 20,6 533,0 914,0 16
26360 7 G 0,75 10,2 107,0 198,0 19 26380 2 x 2,5 9,8 96,0 182,0 14
26361 12 G 0,75 12,6 156,0 294,0 19 26381 3 G 2,5 10,5 150,0 264,0 14
26362 18 G 0,75 14,5 235,0 391,0 19 26382 4 G 2,5 11,2 174,0 350,0 14
26363 25 G 0,75 17,3 313,0 562,0 19 26383 5 G 2,5 12,6 200,0 394,0 14
26364 2x1 7,8 60,0 110,0 18 26384 7 G 2,5 14,8 240,0 450,0 14
26365 3G1 8,1 70,0 131,0 18 26385 12 G 2,5 18,0 410,0 712,0 14
26366 4G1 8,7 86,0 171,0 18

Dimensions and specifications may be changed without prior notice. (RC03)

185
DATA DRAG CHAIN CABLES
Cables for Drag Chains / Data-Cables for Drag Chains

SUPERTRONIC-PVC special cable for drag chains, meter marking

Technical data Cable structure Properties


Special PVC cable for drag chains, adapted to Bare copper, extra fine wire conductors, to Extensively oil resistant
DIN VDE 0285-525-1 / DIN EN 50525-1 DIN VDE 0295 cl.6 Chemical Resistance - see table Technical
Very high flexible due to special construction Core insulation of special PVC Informations
Temperature range compound type TI2 to Adhesion-low
flexing -5C to +70C DIN VDE 0207-363-3 / DIN EN 50363-3 The materials used in manufacture are
fixed installation -40C to +70C Cores colour coded to DIN 47100, see cadmium-free and contain no silicone
Nominal voltage 350 V Technical Informations and free from substances harmful to
Test voltage 1500 V Cores stranded in layers with optimal selected the wetting properties of lacquers
Breakdown voltage min. 3000 V lay-length Tests
Insulation resistance Core wrapping with textile tape PVC self-extinguishing and flame retardant
min. 20 MOhm x km Outer sheath of special PVC acc. to DIN VDE 0482-332-1-2,
Minimum bending radius compound type TM2 to DIN EN 60332-1-2, IEC 60332-1 (equivalent
flexing 5x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1 DIN VDE 0472 part 804 test method B)
fixed installation 3x cable Colour grey (RAL 7001)
Radiation resistance with meter marking Note
up to 80x106 cJ/kg (up to 80 Mrad) AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
The ideal cable for use in cable trays. This high flexible cable is ideal for all areas requiring a high and fast flexing cable including the machine industries,
robotics and all areas of highly mobile machine parts. The long working life offers a secure performance as well as economy. For applications which
go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49550 2 x 0,14 3,5 2,8 23,0 26 49567 12 x 0,25 7,5 30,1 95,0 24
49551 3 x 0,14 3,7 4,1 25,0 26 49568 14 x 0,25 7,9 35,0 107,0 24
49552 4 x 0,14 3,9 5,6 30,0 26 49569 18 x 0,25 8,9 45,0 130,0 24
49553 5 x 0,14 4,2 7,0 35,0 26 49570 24 x 0,25 10,4 60,0 170,0 24
49554 7 x 0,14 4,8 9,8 49,0 26 49571 25 x 0,25 10,5 62,5 177,0 24
49555 10 x 0,14 6,2 14,0 64,0 26 49572 2 x 0,34 4,6 6,8 33,0 22
49556 12 x 0,14 6,3 16,8 71,0 26 49573 3 x 0,34 4,8 10,2 42,0 22
49557 14 x 0,14 6,6 19,6 77,0 26 49574 4 x 0,34 5,2 13,6 56,0 22
49558 18 x 0,14 7,2 25,2 90,0 26 49575 5 x 0,34 6,1 17,0 64,0 22
49559 24 x 0,14 8,5 33,6 119,0 26 49576 7 x 0,34 7,0 23,8 84,0 22
49560 25 x 0,14 8,6 35,0 124,0 26 49577 10 x 0,34 8,4 34,0 116,0 22
49561 2 x 0,25 4,2 5,0 28,0 24 49578 12 x 0,34 8,5 40,8 133,0 22
49562 3 x 0,25 4,4 7,5 33,0 24 49579 14 x 0,34 9,0 47,6 150,0 22
49563 4 x 0,25 4,7 10,0 39,0 24 49580 18 x 0,34 10,1 61,2 182,0 22
49564 5 x 0,25 5,6 12,5 50,0 24 49581 24 x 0,34 12,0 81,5 240,0 22
49565 7 x 0,25 6,1 17,5 63,0 24 49582 25 x 0,34 12,2 85,0 250,0 22
49566 10 x 0,25 7,2 25,0 83,0 24

Dimensions and specifications may be changed without prior notice. (RC03)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

187
Cables for Drag Chains / Data-Cables for Drag Chains

SUPERTRONIC-C-PVC special cable for drag chains, EMC-preferred


type, meter marking

Technical data Cable structure Properties


Special PVC cable for drag chains, adapted to Bare copper, extra fine wire conductors, to Extensively oil resistant
DIN VDE 0285-525-1 / DIN EN 50525-1 DIN VDE 0295 cl.6 Chemical Resistance - see table Technical
Very high flexible due to special construction Core insulation of special PVC Informations
Temperature range compound type TI2 to Adhesion-low
flexing -5C to +70C DIN VDE 0207-363-3 / DIN EN 50363-3 The materials used in manufacture are
fixed installation -40C to +70C Cores colour coded to DIN 47100, see cadmium-free and contain no silicone
Nominal voltage 350 V Technical Informations and free from substances harmful to
Test voltage 1500 V Cores stranded in layers with optimal selected the wetting properties of lacquers
Breakdown voltage min. 3000 V lay-length Tests
Insulation resistance Core wrapping with textile tape PVC self-extinguishing and flame retardant
min. 20 MOhm x km Tinned copper braided screen, acc. to DIN VDE 0482-332-1-2,
Minimum bending radius approx. 85% coverage DIN EN 60332-1-2, IEC 60332-1 (equivalent
flexing 7,5x cable Outer sheath of special PVC DIN VDE 0472 part 804 test method B)
fixed installation 4x cable compound type TM2 to
Radiation resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1 Note
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour grey (RAL 7001) AWG sizes are approximate equivalent
Coupling resistance with meter marking values. The actual cross-section is in mm.
max. 250 Ohm/km

Application
The ideal cable for use in cable trays. This high flexible cable is ideal for all areas requiring a high and fast flexing cable including the machine industries,
robotics and all areas of highly mobile machine parts. The long working life offers a secure performance as well as economy. For applications which
go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49620 2 x 0,14 4,0 11,2 33,0 26 49638 14 x 0,25 8,5 64,2 140,0 24
49621 3 x 0,14 4,2 14,1 36,0 26 49639 18 x 0,25 9,5 78,4 166,0 24
49622 4 x 0,14 4,4 15,5 41,0 26 49640 24 x 0,25 11,0 89,9 210,0 24
49623 5 x 0,14 4,7 18,3 46,0 26 49641 25 x 0,25 11,1 101,0 220,0 24
49624 7 x 0,14 5,3 27,6 70,0 26 49642 2 x 0,34 5,2 16,1 46,0 22
49625 10 x 0,14 6,7 39,3 88,0 26 49643 3 x 0,34 5,4 28,7 62,0 22
49626 12 x 0,14 6,8 41,1 97,0 26 49644 4 x 0,34 5,8 35,7 80,0 22
49627 14 x 0,14 7,1 45,3 105,0 26 49645 5 x 0,34 6,7 39,1 88,0 22
49628 18 x 0,14 7,7 54,1 122,0 26 49646 7 x 0,34 7,6 52,7 116,0 22
49629 24 x 0,14 9,0 66,3 156,0 26 49647 10 x 0,34 9,0 67,4 156,0 22
49630 25 x 0,14 9,1 68,4 162,0 26 49648 12 x 0,34 9,1 76,4 167,0 22
49631 2 x 0,25 4,7 14,9 39,0 24 49649 14 x 0,34 9,6 85,3 195,0 22
49632 3 x 0,25 4,9 18,8 45,0 24 49650 18 x 0,34 10,7 99,7 225,0 22
49633 4 x 0,25 5,2 21,3 52,0 24 49651 24 x 0,34 12,6 147,1 312,0 22
49634 5 x 0,25 5,6 31,0 70,0 24 49652 25 x 0,34 12,8 155,0 325,0 22
49635 7 x 0,25 6,7 39,6 88,0 24
49636 10 x 0,25 7,8 53,9 114,0 24
49637 12 x 0,25 8,1 59,1 128,0 24

Dimensions and specifications may be changed without prior notice. (RC03)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

188
Cables for Drag Chains / Data-Cables for Drag Chains

SUPERTRONIC-PUR special cable for drag chains, meter marking

Technical data Cable structure Properties


Special PUR drag chain cables adapted to Bare copper, extra fine wire conductors, to Features
DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.6, col. 4 and 5 and High flexibility at low temperature, high
DIN EN 50525-2-51 IEC 60228 cl.6 abrasion resistance, break and cut-resistant,
Very high flexible due to special construction Oil resistant PVC core insulation TI2, in tear resistant
Temperature range adapted to DIN VDE 0207-363-3 / Resistant to
flexing -5C to +70C DIN EN 50363-3, for better sliding abilities UV-radiation, Oxygen, Ozone, Hydrolyse, Oil.
fixed installation -40C to +70C Cores are stranded in layer with short Conditional resistant to
Nominal voltage 350 V lay-length Microbes, Hydraulic liquidity,
Test voltage 1500 V Cores colour coded to DIN 47100 Alkalis, Lye.
Breakdown voltage min. 3000 V Core wrapping with textile tape The PUR outer sheath is extremely robust
Insulation resistance Outer sheath of special full-polyurethane with high tear, abrasion and oil-resistance.
min. 20 MOhm x km TMPU to DIN VDE 0207-363-10-2/ Adhesion-low
Minimum bending radius DIN EN 50363-10-2 The materials used in manufacture are
flexing 5x cable Sheath colour grey (RAL 7001), surface mat cadmium-free and contain no silicone
fixed installation 3x cable with meter marking and free from substances harmful to
Radiation resistance the wetting properties of lacquers
up to 100x106 cJ/kg (up to 100 Mrad)
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Perfect for use with cable trays. This highly flexible PUR control cable is ideal for use wherever frequent high flexing motion is required, e. g. in robotics
or all moving parts. The long working life of this cable makes it both efficient and economic. For applications which go beyond standard solutions (for
example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for
drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49583 2 x 0,14 3,5 2,8 22,0 26 49600 12 x 0,25 7,6 30,1 91,0 24
49584 3 x 0,14 3,7 4,1 24,0 26 49601 14 x 0,25 7,9 35,0 102,0 24
49585 4 x 0,14 3,9 5,6 29,0 26 49602 18 x 0,25 8,9 45,0 125,0 24
49586 5 x 0,14 4,2 7,0 33,0 26 49603 24 x 0,25 10,0 60,0 163,0 24
49587 7 x 0,14 4,9 9,8 47,0 26 49604 25 x 0,25 10,6 62,5 170,0 24
49588 10 x 0,14 6,2 14,0 59,0 26 49605 2 x 0,34 4,5 6,8 32,0 22
49589 12 x 0,14 6,4 16,8 67,0 26 49606 3 x 0,34 4,9 10,2 40,0 22
49590 14 x 0,14 6,6 19,6 74,0 26 49607 4 x 0,34 5,3 13,6 55,0 22
49591 18 x 0,14 7,3 25,2 86,0 26 49608 5 x 0,34 5,8 17,0 60,0 22
49592 24 x 0,14 8,5 33,6 115,0 26 49609 7 x 0,34 6,9 23,8 80,0 22
49593 25 x 0,14 8,6 35,0 120,0 26 49610 10 x 0,34 8,4 34,0 112,0 22
49594 2 x 0,25 4,1 5,0 27,0 24 49611 12 x 0,34 8,6 40,8 127,0 22
49595 3 x 0,25 4,3 7,5 33,0 24 49612 14 x 0,34 9,0 47,6 142,0 22
49596 4 x 0,25 4,8 10,0 40,0 24 49613 18 x 0,34 10,1 61,2 175,0 22
49597 5 x 0,25 5,2 12,5 48,0 24 49614 24 x 0,34 12,0 81,5 229,0 22
49598 7 x 0,25 6,2 17,5 60,0 24 49615 25 x 0,34 12,2 85,0 238,0 22
49599 10 x 0,25 7,4 25,0 79,0 24

Dimensions and specifications may be changed without prior notice. (RC03)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

189
Cables for Drag Chains / Data-Cables for Drag Chains

SUPERTRONIC-C-PUR special cable for drag chains, halogen-free,


EMC-preferred type, meter marking

Technical data Cable structure Properties


Special PUR drag chain cables, screened, Bare copper conductors extra fine wire Features
adapted to DIN VDE 0285-525-2-51 / stranded to DIN VDE 0295 cl.6, col. 4 and 5, High flexibility at low temperature, high
DIN EN 50525-2-51 IEC 60228 cl.6 abrasion resistance, break and cut-resistant,
Temperature range Core insulation of PP tear resistant
flexing -30C to +70C Cores are stranded in layer with short Resistant to
fixed installation -40C to +70C lay-length UV-radiation, Oxygen, Ozone, Hydrolyse, Oil
Nominal voltage Cores colour coded to DIN 47100 Conditional resistant to
0,14 mm 350 V Core wrapping with textile tape Microbes, Hydraulic liquidity, Alkalis, Lye
0,25 and 0,34 mm 500 V Tinned copper braided screen, The PUR outer sheath is extremely robust
Test voltage approx. 85% coverage. with high tear, abrasion and oil-resistance
0,14 mm 800 V Outer sheath of special full-polyurethane Adhesion-low
0,25 and 0,34 mm 1200 V TMPU to DIN VDE 0207-363-10-2 / The materials used in manufacture are
Capacitance core/core <80 nF/km DIN EN 50363-10-2 cadmium-free and contain no silicone
Minimum bending radius Sheath colour grey (RAL 7001), surface mat and free from substances harmful to
flexing 7,5x cable with meter marking the wetting properties of lacquers
fixed installation 4x cable
Radiation resistance Note
up to 100x10 AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Used for installation in dry, moist and wet environments as well as for outdoors, for free movement without forced motion and for flexible routing
without forced motion, for proven use as drag-chain cables. Suitable as a highly flexible control cable for fast hoisting and bending stresses in machinery
and tooling construction, in robotics engineering and for continuously moving machinery parts. The long working life of this cable makes it both
efficient and economic. The copper braided screening offers effective protection from both internal and external interference. For applications which
go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49653 2 x 0,14 4,1 11,2 32,0 26 49670 12 x 0,25 8,4 59,1 124,0 24
49654 3 x 0,14 4,3 14,1 35,0 26 49671 14 x 0,25 8,7 64,2 135,0 24
49655 4 x 0,14 4,5 15,5 40,0 26 49672 18 x 0,25 9,5 78,4 160,0 24
49656 5 x 0,14 4,8 18,3 45,0 26 49673 24 x 0,25 11,0 89,9 202,0 24
49657 7 x 0,14 5,7 27,8 66,0 26 49674 25 x 0,25 11,1 101,0 211,0 24
49658 10 x 0,14 6,7 39,3 86,0 26 49675 2 x 0,34 5,0 18,1 45,0 22
49659 12 x 0,14 6,9 42,1 94,0 26 49676 3 x 0,34 5,4 28,7 60,0 22
49660 14 x 0,14 7,1 45,3 102,0 26 49677 4 x 0,34 6,2 35,7 76,0 22
49661 18 x 0,14 7,8 54,1 118,0 26 49678 5 x 0,34 6,7 39,1 82,0 22
49662 24 x 0,14 9,0 66,3 149,0 26 49679 7 x 0,34 7,6 52,7 110,0 22
49663 25 x 0,14 9,1 68,4 156,0 26 49680 10 x 0,34 9,2 67,4 148,0 22
49664 2 x 0,25 4,6 14,9 38,0 24 49681 12 x 0,34 9,4 76,4 166,0 22
49665 3 x 0,25 4,8 18,8 44,0 24 49682 14 x 0,34 10,0 85,5 185,0 22
49666 4 x 0,25 5,3 21,3 51,0 24 49683 18 x 0,34 10,9 99,7 216,0 22
49667 5 x 0,25 5,7 31,0 68,0 24 49684 24 x 0,34 12,6 147,1 300,0 22
49668 7 x 0,25 6,7 39,6 82,0 24 49685 25 x 0,34 12,8 155,0 313,0 22
49669 10 x 0,25 8,2 53,9 110,0 24

Dimensions and specifications may be changed without prior notice. (RC03)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

190
SUPER-PAAR-TRONIC-C-PUR
cableforDragChains,halogen-free,EMC-preferredtype,metermarking

Technicaldata Cablestructure Properties


SpecialDragChaincable,twistedinpairs, Barecopperconductors,extrafinewire Verygoodoilresistant
adaptedtoDINVDE0812 strandedtoDINVDE0295cl.6,col.4, Resistanttoweather,ozone,hydrolysis-
Temperaturerange BS6360cl.6andIEC60228cl.6 andUV-radiation
flexing-30Cto+70C CoreinsulationofPP Chemicalresistanttosolvents,acids,lyes
fixedinstallation-40Cto+70C CoreidentificationtoDIN47100 andhydraulicliquidity
Nominalvoltage350V Corestwistedinpairs,thepairstorsion-free Guaranteedpermanentapplicationin
Testvoltage1500V strandedinlayers multi-shiftoperationunderextremehigh
Insulationresistance Specialfleeceoverouterlayer bendingstress
min.100MOhmxkm Tinnedcopperscreenedbraiding, Highresistanttomechanicalstrain
Mutualcapacitance approx.85%coverage Highpropertyofalternatingbendingstrength
approx.135nF/km Outersheathof full-polyurethane Longlifedurabilitiesthroughlow
Minimumbendingradius compoundtypeTMPUto friction-resistancebyusingthePP-core
flexingat0,25mm DINVDE0207-363-10-2/ insulationwherethecorearestrandedin
7,5xcable DNEN50363-10-2 layers
fixedinstallationat0,25mm Sheathcolourgrey(RAL7001) Hightensilestrength-,abrasion-andimpact
4xcable withmetermarking resistantatlowtemperature
flexingat0,5-1mm Adhesion-low
10xcable Thematerialsusedinmanufactureare
fixedinstallationat0,5-1mm cadmium-freeandcontainnosilicone
5xcable andfreefromsubstancesharmfulto
Couplingresistance thewettingpropertiesoflacquers
max.250Ohm/km
Radiationresistance Note
upto100x106 cJ/kg(upto100Mrad) AWGsizesareapproximateequivalent
values.Theactualcross-sectionisinmm.

Application
ThesepairstrandedandoverallscreenedspecialcablesforDragChainsoffertheoperationalpossibilitieswheretheouterelectricalinfluencesathigh
frequencecauseinterferenceofimpulsetransmission,areappliedforpermanentflexibleoperationsinmachineries,machinetools,robottechnics,
formovableautomatedmachinerypartsandmulti-shift-operationasatransmission-cable.Thesehighflexibledatacablesaredevelopedaccording
totheneweststateoftechnologyimprovementandwithitsslidingabilitiesbyusingthePP-coreinsulationandadhesion-lowandcut-resistant
PUR-outersheath,guaranteedanoptimumlifedurabilitiesandhighlyeconomic.Forapplicationswhichgobeyondstandardsolutions(forexample
forcompostingappliancesorhighshelfconveyorswithextremelyhighprocessingspeedsetc.)werecommendforourespeciallydevelopedenquiry
sheetforenergyguidingsystems.Beforeinstallationincabletrayspleasereadtheinstructions.FurthertechnicaldetailsseeselectiontableforDrag
Chaincables,seeleadtext.
EMC =Electromagneticcompatibillity
TooptimizetheEMCfeatureswerecommendalargeroundcontactofthecopperbraidingonbothends.
=TheproductisconformedwiththeECLow-VoltageDirective2006/95/EC.

Partno. No.pairsx Outer Cop. Weight AWG-No. Partno. No.pairsx Outer Cop. Weight AWG-No.
cross-sec. app.mm weight app. cross-sec. app.mm weight app.
mm kg/km kg/km mm kg/km kg/km
19101 1 x2 x0,25 4,9 14,0 28,0 24 19128 1 x2 x0,75 6,5 34,0 61,0 19
25.01.2016/Dimensionsandspecificationsmaybechangedwithoutpriornotice.

19102 2 x2 x0,25 6,8 32,0 61,0 24 19129 2 x2 x0,75 9,3 60,0 113,0 19
19103 3 x2 x0,25 7,2 38,4 73,0 24 19130 3 x2 x0,75 9,8 85,7 158,0 19
19104 4 x2 x0,25 7,7 43,2 90,0 24 19131 4 x2 x0,75 10,6 93,6 173,0 19
19105 5 x2 x0,25 8,6 51,5 105,0 24 19132 5 x2 x0,75 11,7 113,0 203,0 19
19106 6 x2 x0,25 9,2 71,8 133,0 24 19133 6 x2 x0,75 12,7 130,4 231,0 19
19107 8 x2 x0,25 10,6 74,4 156,0 24 19134 8 x2 x0,75 14,9 192,2 343,0 19
19108 10 x2 x0,25 11,7 90,0 188,0 24 19135 10 x2 x0,75 16,6 258,0 467,0 19
19109

14 x2 x0,25 12,7 111,2 220,0 24 19136

14 x2 x0,75 18,2 316,6 546,0 19
19119 1 x2 x0,5 5,7 22,0 47,0 20 19137 1 x2 x1 6,9 42,0 71,0 18
19120 2 x2 x0,5 8,2 50,0 100,0 20 19138 2 x2 x1 9,9 73,0 130,0 18
19121 3 x2 x0,5 8,8 71,8 131,0 20 19139 3 x2 x1 10,5 93,6 170,0 18
19122 4 x2 x0,5 9,6 74,4 149,0 20 19140 4 x2 x1 11,6 117,8 204,0 18
19123 5 x2 x0,5 10,6 84,5 169,0 20 19141 5 x2 x1 12,8 139,0 238,0 18
19124 6 x2 x0,5 11,5 99,6 196,0 20
19125 8 x2 x0,5 13,4 144,3 285,0 20
19126 10 x2 x0,5 14,9 176,0 344,0 20
19127 14 x2 x0,5 16,5 215,4 401,0 20

Dimensionsandspecificationsmaybechangedwithoutpriornotice.(RC03)
Cables for Drag Chains / Data-Cables for Drag Chains

SENSORFLEX-H sensor actuator cables, halogen-free, high flexible drag chain


cable, PUR

Technical data Cable structure Properties


Temperature range SENSORFLEX-H (Li12Y11Y) low adhesion, extremely abrasion resistant,
flexing -30C to +80C Bare copper-conductor, to resistant to hydrolysis and microbial attack
fixed installation -40C to +80C DIN VDE 0295 cl.6, extra fine-wire, Highly flexible drag chain cable
Operating voltage BS 6360 cl.6, IEC 60228 cl.6
up to 0,25 mm 350 V Core insulation of TPE
from 0,34 mm 500 V Core identification see table below
A.c. test voltage, 50 Hz Outer sheath of PUR
up to 0,25 mm 1200 V Sheath colour see table below
from 0,34 mm 2000 V SENSORFLEX-H (Li9Y11Y)
Minimum bending radius Bare copper-conductor, to
SENSORFLEX-H (Li12Y11Y) DIN VDE 0295 cl.6, extra fine-wire,
5x cable BS 6360 cl.6, IEC 60228 cl.6
SENSORFLEX-H (Li9Y11Y) Core insualtion of PP
7,5x cable Core identification see table below
Outer sheath of PUR
Sheath colour see table below

Application
For decentralised installation and control technology. These cables are used in connector systems for sensors and actuators. In combination with
injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element between the periphery and the PLC
in production systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also
in the entire manufacturing industry. While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now
field bus technology has made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. Moving the
I/O points to the system periphery enables significant reductions in installation costs.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
SENSORFLEX-H (Li12Y11Y) sensor actuator cables, halogen-free, high flexible drag chain cable, PUR
Part no. Cable structure AWG-No.
black grey No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** approx. weight approx.
mm mm kg / km kg / km
76283 76299 2 x 0,25 PUR BN, BU X 4,4 4,8 22,0 24
76284 76300 3 x 0,25 PUR BN, BU, BK X 4,4 7,2 22,0 24
76285 76301 4 x 0,25 PUR BN, BU, BK, WH X 4,7 9,6 26,0 24
76286 76302 5 x 0,25 PUR BN, BU, BK, WH, GY X 4,8 12,0 30,0 24
76287 76303 2 x 0,34 PUR BN, BU X 4,9 6,5 30,0 22
76288 76304 3 x 0,34 PUR BN, BU, BK X 4,9 9,8 30,0 22
76289 76305 4 x 0,34 PUR BN, BU, BK, WH X 5,2 13,1 43,0 22
76290 76306 5 x 0,34 PUR BN, BU, BK, WH, GY X 5,9 16,4 54,0 22
78265 78266 5 G 0,34 PUR BN, BU, BK, WH, GN-YE X 5,9 16,4 54,0 22
76291 76307 2 x 0,5 PUR BN, BU X 5,0 9,6 40,0 20
78267 78268 3 G 0,5 PUR BK with number, GN-YE X 5,7 14,4 43,0 20
76292 76308 3 x 0,5 PUR BN, BU, BK X 5,0 14,4 40,0 20
76293 76309 4 x 0,5 PUR BN, BU, BK, WH X 5,5 19,2 47,0 20
76294 76310 5 x 0,5 PUR BN, BU, BK, WH, GY X 6,0 24,0 55,0 20

Continuation

192
Cables for Drag Chains / Data-Cables for Drag Chains

SENSORFLEX-H sensor actuator cables, halogen-free, high flexible drag chain


cable, PUR
SENSORFLEX-H (Li12Y11Y) sensor actuator cables, halogen-free, high flexible drag chain cable, PUR
Part no. Cable structure AWG-No.
black grey No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** approx. weight approx.
mm mm kg / km kg / km
76295 76311 2 x 0,75 PUR BN, BU X 5,7 14,4 47,0 18
78269 78270 3 G 0,75 PUR BN, BU, GN-YE X 5,9 21,6 54,0 18
76296 76312 3 x 0,75 PUR BN, BU, BK X 5,9 21,6 54,0 18
78271
76297
78273
78272
76313
78274
4 G 0,75
4 x 0,75
5 G 0,75
PUR
PUR
PUR
BN, BU, BK, GN-YE
BN, BU, BK, WH
BK with number, GN-YE
X
X
X
6,2
6,0
7,0
28,8
28,8
36,0
67,0
66,0
80,0
18
18
18
C
76298 76314 5 x 0,75 PUR BN, BU, BK, WH, GY X 7,0 36,0 80,0 18

SENSORFLEX-H (Li9Y11Y) sensor actuator cables, halogen-free, high flexible drag chain cable, PUR
Part no. Cable structure AWG-No.
Sheath colour No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** approx. weight approx.
mm mm kg / km kg / km
75801 GY RAL 7001 3 x 0,25 PUR BN, BU, BK X 4,5 7,2 22,0 24
77468 GY RAL 7001 4 x 0,25 PUR BN, BU, BK, WH X 4,7 9,6 26,0 24
76705 GY RAL 7001 8 x 0,25 PUR DIN 47100 X 6,0 19,2 49,0 24
77427 GY RAL 7001 4 x 0,34 PUR BN, BU, BK, WH X 4,9 13,1 43,0 22
77428 GY RAL 7001 3 G 0,75 PUR BK with number, GN-YE X 6,2 21,6 54,0 18
78275 GY RAL 7001 3 x 0,75 PUR BK with number, GN-YE X 6,2 21,6 54,0 18
77429 GY RAL 7001 4 G 0,75 PUR BK with number, GN-YE X 6,2 28,8 66,0 18

Dimensions and specifications may be changed without prior notice.

193
MOTOR, SERVO, & FEEDBACK CABLES

3
in

E
VD eld 29
ng

x
xe
ex

VD
ed
U

R/ shi E 0
xi
- fi
- fl

./
0 /

le

ed
i

no
H A ed / VD
-f

-f
U
C)

C)

ge

us

us

CS REG
e n es /
(

e
lta

di

di

se
re

re

t
fre

ut tan

r
n
ra

ra

co
tu

tu

u
vo

E
ai
n-

or
sis
ra

ra

A
d
ch
al

ge
in

in
pe

pe

re
do
re
in

ge
nd

nd

ag
lo

lo

re
V-
m

L/
om

Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
D

N
Motor, servo, and feedback cables

TOPFLEX 600-PVC -15 to +80 -40 to +80 0.6/1 kV 7.5x 4x 197

TOPFLEX 600-C-PVC

-15 to +80 -40 to +80 0.6/1 kV 7.5x 4x X 198

TOPFLEX 611-PUR -30 to +80 -40 to +80 0.6/1 kV 7.5x 4x X X X X 199

TOPFLEX 611-C-PUR

-30 to +80 -40 to +80 0.6/1 kV 10x 5x X X X X X 200

TOPSERV 110 / 120



-30 to +80 -40 to +80 0.6/1 kV 7.5x 4x X X X X X 201

Feedback cable -5 to +70 -30 to +80 350 10x X X 202

Feedback cable PUR -30 to +80 -40 to +80 250 10x 5x X X X X X 203

TOPFLEX - EMV-2YSLCYK-J +5 to +70 -40 to +70 0.6/1 kV 20x 10x X X 204

TOPFLEX - EMV-3 PLUS 2YSLCY-J +5 to +70 -40 to +70 0.6/1 kV 20x 10x X X 205

TOPFLEX - EMV-UV-2YSLCYK-J -5 to +70 -40 to +70 0.6/1 kV 20x 10x X X X X 206


TOPFLEX - EMV-UV-3 PLUS
-5 to +70 -40 to +70 0.6/1 kV 20x 10x X X X X 207
2YSLCYK-J
TOPFLEX - EMV-UV-2XSLCYK-J -5 to +90 -40 to +90 0.6/1 kV 20x 10x X X X X 209
TOPFLEX - EMV-UV-3 PLUS
-5 to +90 -40 to +90 0.6/1 kV 20x 10x X X X X 211
2XSLCYK-J
TOPFLEX - EMV-UV-2XSLCH-J

-5 to +90 -40 to +90 0.6/1 kV 20x 10x X X X 213
TOPFLEX - EMV-UV-3 PLUS
-5 to +90 -40 to +90 0.6/1 kV 20x 10x X X X 215
2XSLCH-J
TOPFLEX MOTOR 109 -5 to +70 -40 to +80 0.6/1 kV 20x 10x X X X X X 217

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

195
SELECTION TABLE - DRAG CHAIN CABLES

ng
in

xi

g
/s 2
ce

fle

in
/
an

ex
ge U
(m
-
es ist

lta 0 /

- fl
us

)
-c t d

vo U
/s
di

io
)

C)
g ge
en

(m
ra

at
or

(
tin lta
er
m

re
in

s
25
e

el

nt
ra vo
ee

le

ui CSA
ov

nd

tu

s
c

yc
)

al
to

le
sp

ac

pe l

ra
ia
m

O ina
be

ov
r

.c
up

va
te

eq L/
er

pe
.

ge
.

ax

ax
ou

pr
ax
ax
m

om
.

at
in

U
m
=

Ap
M

M
0

Pa
M
M

M
M
(D
(1

Te
N
PUR motor & servo cables for drag chains
TOPFLEX 611-PUR 30 7.5 x D 4 50 11 Mio PP/PUR 600/1000V -30 to +80 199 431
TOPFLEX 611 C-PUR

30 10 x D 4 50 11 Mio PP/CU/PUR 600/1000V -30 to +80 200 437
TOPSERV 110 30 7.5 x D 3 10 11 Mio PP/CU/PUR 600/1000V -30 to +80 201 468
TOPSERV 120 30 7.5 x D 3 10 11 Mio PP/CU/PUR 600/1000V -30 to +80 201 468
PUR feedback cables for drag chain cables
Tachofeedback-cable-C-PUR 30 10 x D 4 50 9 Mio PP/CU/PUR 450V -30 to +80 203 470
Incremental encoder cable C-PUR 30 10 x D 4 50 9 Mio PP/CU/PUR 250V -30 to +80 203 470
TOPFLEX-PUR 30 10 x D 4 50 9 Mio PP/CU/PUR 350V -30 to +80 203 470

A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties and the selection tables cables in drag chains,
see pages 1030 and 1031.

196
Motor-, Servo and Feedback Cables

TOPFLEX 600-PVC motor power supply cable 0,6/1kV, meter marking

D
Technical data Cable structure Properties
Special PVC-insulated sheathed cable Bare copper-conductor, to PVC outer sheath: extensively oil resistant
adapted to DIN VDE 0293, 0295 DIN VDE 0295 cl.5, fine-wire, Chemical Resistance - see table Technical
Temperature range IEC 60228 cl.5 Informations
flexing -15C to +80C Core insulation of PVC The materials used in manufacture are
fixed installation -40C to +80C Core identification to DIN VDE 0293 cadmium-free and contain no silicone
Nominal voltage U0/U 600/1000 V black cores with continuous white and free from substances harmful to
Test voltage 4000 V numbering the wetting properties of lacquers
Breakdown voltage GN-YE conductor Tests
min. 8000 V Cores stranded in layers with PVC self-extinguishing and flame retardant
Insulation resistance optimal lay-length acc. to DIN VDE 0482-332-1-2,
min. 20 MOhm x km Outer sheath of special PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius Sheath colour grey (RAL 7001) DIN VDE 0472 part 804 test method B)
flexing 7,5x cable with meter marking
fixed installation 4x cable Note
Radiation resistance For use in drag chains, we
up to 80x106 cJ/kg (to 80 Mrad) recommend our versions
TOPFLEX 611-PUR and
TOPFLEX 611-C-PUR
screened analogue type:
TOPFLEX 600-C-PVC, confer page 198

Application
As supply cable for electronically controlled servo-motors and connections to DNC motors. The cable is suitable for permanent and flexible installation
for medium mechanical loads in dry, damp and wet environments.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22860 4 G 1,5 9,6 58,0 130,0 16 22866 4 G 25 27,4 960,0 1805,0 4
22861 4 G 2,5 11,2 95,0 220,0 14 22867 4 G 35 30,0 1344,0 2060,0 2
22862 4G4 13,0 154,0 330,0 12 22868 4 G 50 35,8 1920,0 2900,0 1
22863 4G6 14,5 231,0 445,0 10 22869 4 G 70 40,9 2640,0 4050,0 2/0
22864 4 G 10 18,2 384,0 660,0 8 22854 4 G 95 46,2 3648,0 5540,0 3/0
22865 4 G 16 22,3 615,0 1060,0 6 22855 4 G 120 51,6 4608,0 7000,0 4/0

Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

197
Motor-, Servo and Feedback Cables

TOPFLEX 600-C-PVC motor power supply cable 0,6/1kV, EMC prefered


type, meter marking

Technical data Cable structure Properties


Special PVC-insulated sheathed cable Bare copper-conductor, to PVC outer sheath largely oil resistant, for
adapted to DIN VDE 0293, 0295 DIN VDE 0295 cl.5, fine-wire, Chemical Resistance - see table Technical
Temperature range IEC 60228 cl.5 Informations
flexing -15C to +80C Core insulation of PVC The materials used in manufacture are
fixed installation -40C to +80C Core identification to DIN VDE 0293 cadmium-free and contain no silicone
Nominal voltage U0/U 600/1000 V black cores with continuous white and free from substances harmful to
Test voltage 4000 V numbering the wetting properties of lacquers
Breakdown voltage GN-YE conductor Tests
min. 8000 V Cores stranded in layers with PVC self-extinguishing and flame retardant
Coupling resistance optimal lay-length acc. to DIN VDE 0482-332-1-2,
max. 250 Ohm/km Inner sheath of DIN EN 60332-1-2, IEC 60332-1 (equivalent
Insulation resistance Tinned copper braided screen, DIN VDE 0472 part 804 test method B)
min. 20 MOhm x km approx. 85% coverage
Minimum bending radius Outer sheath of special PVC Note
flexing 7,5x cable Colour grey (RAL 7001) For use in drag chains, we
fixed installation 4x cable with meter marking recommend our versions
Radiation resistance TOPFLEX 611-PUR and
up to 80x106 cJ/kg (to 80 Mrad) TOPFLEX 611-C-PUR
unscreened analogue type:
TOPFLEX 600-PVC, confer page 197

Application
As supply cable for electronically controlled servo-motors and connections to DNC motors. The cable is suitable for permanent and flexible installation
for medium mechanical loads in dry, damp and wet environments.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22960 4 G 1,5 11,8 99,0 250,0 16 22966 4 G 25 31,7 1169,0 1920,0 4
22961 4 G 2,5 13,8 169,0 360,0 14 22967 4 G 35 34,5 1680,0 2515,0 2
22962 4G4 15,7 234,0 530,0 12 22856 4 G 50 40,7 2370,0 3315,0 1
22963 4G6 17,3 316,0 620,0 10 22857 4 G 70 46,0 3257,0 4600,0 2/0
22964 4 G 10 21,5 549,0 1050,0 8 22858 4 G 95 51,3 4060,0 6060,0 3/0
22965 4 G 16 26,1 807,0 1465,0 6 22859 4 G 120 56,4 5231,0 7315,0 4/0

Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

198
Motor-, Servo and Feedback Cables

TOPFLEX 611-PUR motor power supply cable 0,6/1kV, cable for drag
chain, halogen-free, meter marking

D
Technical data Cable structure Properties
Special-PUR drag chain cable Bare copper-conductor, to Adhesion-free, extremely abrasion
adapted to DIN VDE 0293, 0295, 0250, DIN VDE 0295 cl.6, extra fine-wire, resistant, halogen-free, resistant to
DIN VDE 0285-525-1 / DIN EN 50525-1 BS 6360 cl.6, IEC 60228 cl.6 hydrolysis and microbial attack
Temperature range Core insualtion of PP resistant to UV-radiation,
flexing -30C to +80C Core identification to DIN VDE 0293 oxygen and ozone
fixed installation -40C to +80C black cores with continuous white The materials used in manufacture are
Nominal voltage U0/U 600/1000 V numbering cadmium-free and contain no silicone
Test voltage 4000 V GN-YE conductor and free from substances harmful to
Insulation resistance Cores stranded together with optimal the wetting properties of lacquers
min. 20 MOhm x km lay-length and stabilising filler
Min. bending radius Fleece wrapping facilitates sliding Note
flexing 7,5x cable Outer sheath of PUR G = with green-yellow conductor
fixed installation 4x cable Sheath colour grey (RAL 7001) For extreme applications extending beyond
with meter marking standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems.
Please observe applicable installation
regulations for use in energy supply chains.
screened analogue type:
TOPFLEX 611-C-PUR, confer page 200

Application
As optimized supply cable for the supply to motors, in particular to DNC motors, servo-motors. These cables are specially designed for use in power
drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. Optimised insulation materials ensure
resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents. Favourable outer diameters, reduced
weights and enhanced torsion characteristics assure the use in multi-layer operations with extremely high continuous bending loads. Suitable for
outdoor use.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22870 4 G 1,5 8,0 58,0 125,0 16 22876 4 G 25 26,9 960,0 1510,0 4
22871 4 G 2,5 10,8 95,0 215,0 14 22877 4 G 35 30,7 1344,0 2100,0 2
22872 4G4 12,5 154,0 310,0 12 22978 4 G 50 36,5 1920,0 2950,0 1
22873 4G6 14,8 231,0 470,0 10 22979 4 G 70 41,6 2640,0 4090,0 2/0
22874 4 G 10 18,8 384,0 760,0 8 22980 4 G 95 48,2 3648,0 5580,0 3/0
22875 4 G 16 22,8 615,0 1250,0 6 22981 4 G 120 51,6 4608,0 7040,0 4/0

Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

199
Motor-, Servo and Feedback Cables

TOPFLEX 611-C-PUR Motor power supply cable for drag chains


0,6/1kV, EMC preferred type, halogen-free, meter marking

Technical data Cable structure Properties


Special-PUR drag chain cable Bare copper-conductor, to Adhesion-free, extremely abrasion
adapted to DIN VDE 0293, 0295, 0250, DIN VDE 0295 cl.6, extra fine-wire, resistant, halogen-free, resistant to
DIN VDE 0285-525-1 / DIN EN 50525-1 BS 6360 cl.6, IEC 60228 cl.6 hydrolysis and microbial attack
Temperature range Core insualtion PP resistant to UV-radiation,
flexing -30C to +80C Core identification to DIN VDE 0293 oxygen and ozone
fixed installation -40C to +80C black cores with continuous white The materials used in manufacture are
Nominal voltage U0/U 600/1000 V numbering cadmium-free and contain no silicone
Test voltage 4000 V GN-YE conductor and free from substances harmful to
Coupling resistance Cores stranded together with optimal the wetting properties of lacquers
max. 250 Ohm/km lay-length and stabilising filler
Insulation resistance Fleece wrapping facilitates sliding Note
min. 20 MOhm x km Inner sheath of TPE G = with green-yellow conductor
Min. bending radius Tinned copper braided screen, For extreme applications extending beyond
flexing 10x cable approx. 85% coverage standard solutions we recommend that
fixed installation 5x cable Outer sheath of PUR you request our questionnaire, which has
Sheath colour grey (RAL 7001) been especially designed for energy supply
with meter marking systems.
Please observe applicable installation
regulations for use in energy supply chains.
unscreened analogue type:
TOPFLEX 611-PUR, confer page 199

Application
As optimized supply cable for the supply to motors, in particular to DNC motors, servo-motors. These cables are specially designed for use in power
drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. Optimised insulation materials ensure
resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents. Favourable outer diameters, reduced
weights and enhanced torsion characteristics assure the use in multi-layer operations with extremely high continuous bending loads. Suitable for
outdoor use.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22970 4 G 1,5 11,3 99,0 220,0 16 22976 4 G 25 31,2 1169,0 1990,0 4
22971 4 G 2,5 13,5 169,0 340,0 14 22977 4 G 35 35,2 1680,0 2535,0 2
22972 4G4 16,0 234,0 490,0 12 22982 4 G 50 42,5 2370,0 3360,0 1
22973 4G6 17,8 316,0 680,0 10 22983 4 G 70 48,8 3257,0 4650,0 2/0
22974 4 G 10 22,2 549,0 1035,0 8 22984 4 G 95 54,6 4060,0 6090,0 3/0
22975 4 G 16 27,2 807,0 1460,0 6 22985 4 G 120 58,5 5231,0 7380,0 4/0

Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

200
Motor-, Servo and Feedback Cables

TOPSERV 110 / 120 PUR servo cable with 1 or 2 signal pairs 0,6/1kV,
high flexible, cable for drag chain, EMC preferred type

D
Technical data Cable structure Properties
Spezial-PUR drag chain cable Bare copper-conductor, to low capacitance by using PP as core
adapted to DIN VDE 0295, 0250, DIN VDE 0295 cl.6, extra fine-wire insulation
DIN VDE 0285-525-1-1/DIN EN 50525-1 Core insulation of halogen-free PP PUR-outer sheath low adhesion,
Temperature range Core identification resistant to hydrolysis and microbial attack,
flexing -30C to +80C power supply cores halogen-free
fixed installation -40C to +80C core 1: black with imprint U/L1/C/L+ These highly flexible cables are fitted with
Nominal voltage core 2: black with imprint V/L2 an additional overall screen to assure EMC
power supply cores U0/U 600/1000 V core 3: black with imprint W/L3/D/L- compatibility, i.e. the protection against
control cores U0/U 300/500 V control cores electromagnetic interference
Test voltage TOPSERV 110 The materials used in manufacture are
power supply cores 4000 V core 1 black with imprint BR1 cadmium-free and contain no silicone
control cores 1000 V core 2 black with imprint BR2 and free from substances harmful to
Power rating TOPSERV 120 the wetting properties of lacquers
to DIN VDE 0298 part 4 pair 1: black with number no. 5+6
Insulation resistance pair 2: black with number no. 7+8 Note
min. 20 MOhm x km GN-YE conductor For extreme applications extending beyond
Minimum bending radius Screening of the control cores in pairs, standard solutions we recommend that
flexing 7,5x cable tinned drain wire and you request our questionnaire, which has
fixed installation 4x cable tinned Cu braid been especially designed for energy supply
Coupling resistance Control cores stranded in pairs and laid up in systems.
max. 250 Ohm/km layers together with the power supply cores Please observe applicable installation
Foil wrapping regulations for use in energy supply chains.
Overall screening of tinned cu braid, AWG sizes are approximate equivalent
visible coverage min. 80% values. The actual cross-section is in mm.
Fleece wrapping Servo-cable and Feedback-cable
Outer sheath of PUR with UL-approval to e.g. Siemens,
Sheath colour petrol (RAL 5018) Bosch Rexroth, Lenze etc. can be
found in chapter N ...

Application
The combination of feeder cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision servomotors,
as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting cables. These requirements
are met to a high degree as is the electromagnetic compatibillity (EMC). These cables can also be used as drag chain cables. Manufacturing is based
on specifications from renowned manufacturers of servo-actuators and servo-controls as well as in accordance with diverse VDE standards. Application
for system SIMODRIVE.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPSERV 110 (1 pair screened and overall screening) TOPSERV 120 (2 pairs individually screened and overall
Part no. No.cores x Outer Cop. Weight AWG-No. screening)
cross-sec. approx. weight approx. Part no. No.cores x Outer Cop. Weight AWG-No.
mm mm kg / km kg / km cross-sec. approx. weight approx.
71491 ( 4 G 1,5 + (2 x 1,0)) 11,5 139,0 211,0 16 mm mm kg / km kg / km
71493 ( 4 G 2,5 + (2 x 1,0)) 13,6 188,0 273,0 14 71990 ( 4 G 1,5 + 2 x (2 x 1,0)) 12,6 186,0 242,0 16
71705 ( 4 G 4 + (2 x 1,0)) 14,6 260,0 352,0 12 71991 ( 4 G 2,5 + 2 x (2 x 1,0)) 15,0 231,0 316,0 14
71706 ( 4 G 6 + (2 x 1,0)) 16,0 360,0 500,0 10 71992 ( 4 G 4 + 2 x (2 x 1,0)) 16,0 308,0 415,0 12
71707 ( 4 G 10 + (2 x 1,0)) 20,2 590,0 753,0 8 71993 ( 4 G 6 + 2 x (2 x 1,0)) 18,2 420,0 574,0 10
71708 ( 4 G 16 + (2 x 1,0)) 23,8 845,0 1061,0 6 71994 ( 4 G 10 + 2 x (2 x 1,0)) 22,8 647,0 805,0 8
71709 ( 4 G 25 + (2 x 1,0)) 27,0 1320,0 1499,0 4 71995 ( 4 G 16 + 2 x (2 x 1,0)) 25,0 918,0 1122,0 6
71710 ( 4 G 35 + (2 x 1,0)) 31,9 1840,0 1992,0 2 71996 ( 4 G 25 + 2 x (2 x 1,0)) 27,7 1400,0 1584,0 4
71711 ( 4 G 50 + (2 x 1,0)) 36,7 2530,0 2880,0 1 72106 ( 4 G 35 + 2 x (2 x 1,0)) 32,0 1882,0 2185,0 2
71997 ( 4 G 50 + 2 x (2 x 1,0)) 37,0 2574,0 2977,0 1
Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

201
Motor-, Servo and Feedback Cables

Feedback cables PVC EMC-preferred type, meter marking

Technical data Cable structure Properties


Special core and sheath compound of PVC Bare copper, fine and/or ultra-fine wire Largely oil-resistant, for oil-/ chemical
Temperature range conductors acc. to DIN VDE 0295 cl.5 Resistance see Technical Information table
flexing -5C to +70C and/or IEC 60228 The materials used in manufacture are
fixed installation -30C to +80C Core insulation of PVC cadmium-free and contain no silicone
Nominal voltage 350 V Part No. 22800 Cu-screen of single and free from substances harmful to
Test voltage pairs and PVC sheath the wetting properties of lacquers
core/core 2000 V Core identification see table below Tests
core/screen 1000 V Single cores or pairs stranded PVC self-extinguishing and flame retardant
Insulation resistance in layer with optimal lay-length acc. to DIN VDE 0482-332-1-2,
min. 20 MOhm x km Core wrapping with film DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius Tinned copper braided screen, DIN VDE 0472 part 804 test method B)
10x cable approx. 85% coverage
Coupling resistance Outer sheath of special PVC Note
max. 250 Ohm/km Colour grey (RAL 7001) AWG sizes are approximate equivalent
with meter marking values. The actual cross-section is in mm.

Application
These feedback cables are used in machinery and control construction as well as in plant engineering as these enable an excellent transmission of data
and signals. Additional cores for the power supply to individual components are available.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX-PVC
Part No.cores x Core Core Sheath Outer Cop. Weight AWG-No.
no. cross-sec. marking marking colour approx. mm weight approx.
mm 0,14 mm 0,5 mm kg / km kg / km
22800 ( 3 x (2 x 0,14) + (2 x 0,5)) GN+YE, GY+PK, BU+RD WH, BN Grey 8,5 78,0 112,0 26
22806 ( 4 x 2 x 0,14 + 4 x 0,5) RD+BK, BN+GN, YE+VT, GN+PK WH, BU, WH/GN, BN/GN Grey 8,5 68,0 111,0 26
22845 ( 10 x 0,14 + 2 x 0,5) DIN 47100 WH, BN Grey 8,0 46,2 70,0 26
22846 ( 10 x 0,14 + 4 x 0,5) DIN 47100 WH, BN, GN, YE Grey 8,2 56,3 86,0 26

Incremental feedback-cable
Part No.cores x Core Core Sheath Outer Cop. Weight AWG-No.
no. cross-sec. marking marking colour approx. mm weight approx.
mm 0,25 mm 1 mm kg / km kg / km
22825 ( 4 x 2 x 0,25 + 2 x 1,0) BN+GN, RD+BK, VT+BU, GY+PK WH, BN Grey 8,8 66,0 110,0 24

Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

202
Motor-, Servo and Feedback Cables

Feedback cables PUR high flexible feedback cables for drag chain,
EMC-preferred type, meter marking

D
Technical data Cable structure Properties
Temperature range Bare copper-conductor, to Special PUR outer sheath low adhesion
flexing -30C to +80C DIN VDE 0295 cl.6, extra fine-wire, Resistant to
fixed installation -40C to +80C BS 6360 cl.6, IEC 60228 cl.6 Oils and fats
Nominal voltage Core insualtion of PP Acids and alkalis
TOPFLEX-PUR 350 V Part No. 22847 Cu-screen of single pairs Hydraulic fluids
Tachofeedback-cable-C-PUR 450 V or single cores and PETP (polyethylene Oxygen and ozone
Incremental Feedback-cable-C-PUR 250 V terephthalate) sheath UV-radiation
Test voltage Core identification see table below Hydrolysis
core/core 2000 V Single cores or pairs stranded Microbial attack
core/screen 1000 V in layer with optimal lay-length Water and weathering effects
Insulation resistance (pairs part no. 22818) The high abrasion resistance and notch
min. 20 MOhm x km Drain wire resistance meet the highest requirements
Minimum bending radius Tinned copper braided screen, The materials used in manufacture are
flexing 10x cable approx. 85% coverage cadmium-free and contain no silicone
fixed installation 5x cable Outer sheath of special PUR, matt and free from substances harmful to
Coupling resistance Sheath colour see table below the wetting properties of lacquers
max. 250 Ohm/km
Radiation resistance Note
up to 100x106 cJ/kg (up to 100 Mrad) For extreme applications extending beyond
standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems.
Please observe the assembly instruction
for use in energy supply chains.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Both cables fulfil different tasks for the control of servo-motors. The tachofeedback-cable or response cable serves the regulation of the motor speed
and measurement of the actual values. The incremental feedback-cable or position response cable transfers the control signals for positioning and
engineering characteristics and is used as the flexible connecting cable for tachometer, brakes and pulse transmitter in case of high mechanical stress
in plant, machine and control engineering in dry, moist and wet rooms. Particularly suitable for continuous operating in drag chains, industrial robotics
and handling equipment as these cables enable an excellent transmission of data and signals. Additional cores for the power supply to individual
components are available. The braided screen guarantees reliable signal transmission. Optimum functionality, long service life and an excellent
cost-performance ratio are given for the mentioned applications by the special compounds used for insulation and sheath.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX-PUR
Part No.cores x Core Core Sheath Outer Cop. Weight AWG-No.
no. cross-sec. marking marking colour approx. mm weight approx.
mm 0,14 mm 0,5 mm kg / km kg / km
22847 ( 3 x (2 x 0,14) + (2 x 0,5)) DIN 47100 WH, BN Grey 8,3 78,0 103,0 26
22852 4 x 2 x 0,14 + 4 x 0,5 BN+GN, YE+VT, GY+PK, RD+BU WH, BN, WH/GN, BN/GN Grey 8,4 73,0 105,0 26
22849 ( 10 x 0,14 + 2 x 0,5) DIN 47100 WH, BN Grey 7,2 39,0 83,0 26

Tachofeedback-cable
Part No.cores x Core Core Sheath Outer Cop. Weight AWG-No.
no. cross-sec. marking marking colour approx. mm weight approx.
mm 0,5 mm - kg / km kg / km
22823 ( 9 x 0,5) WH, BN, GN, YE, GY, PK, BU, RD, BK - Orange 8,8 80,8 128,0 20

Incremental feedback cable


Part No.cores x Core Core Sheath Outer Cop. Weight AWG-No.
no. cross-sec. marking marking colour approx. mm weight approx.
mm 0,14 mm 1 mm kg / km kg / km
22818 ( 4 x 2 x 0,25 + 2 x 1,0) RD+BK, BN+GN, YE+VT, GN+PK WH, BN Orange 8,8 65,2 105,0 24

Dimensions and specifications may be changed without prior notice. (RD01)

203
Motor-, Servo and Feedback Cables

TOPFLEX -EMV-2YSLCY-J for power supply connections to frequency


converters, double screened, 0,6/1kV, meter marking

Technical data Cable structure Properties


Special motor power supply cable for Bare copper-conductor, to Low mutual capacitance
frequency converters adapted to DIN VDE 0295 cl.5, fine-wire, Low coupling resistance for high
DIN VDE 0250 BS 6360 cl.5, IEC 60228 cl.5 electromagnetic compatibility
Temperature range Core insulation of polyethylene (PE) This screened motor supply cable with
flexing +5C to +70C Core identification BN, BK, GY low mutual capacitance of the single cores
fixed installation -40C to +70C GN-YE conductor because of the special PE core insulation
Nominal voltage U0/U 600/1000 V Cores stranded in concentric layers and low screen capacitance enable a low-loss
Max. operating voltage 1. Screen with special aluminium film transmission of the power compared to
A.C. and 3-phase 700/1200 V 2. Tinned copper braided screen, PVC-sheathed connecting cables
DC operation 900/1800 V approx. 85% coverage Due to the optimal screening an
Test voltage 4000 V Outer sheath of special PVC interference-free operation of
Insulation resistance Sheath colour transparent frequency converters is obtained
min. 200 MOhm x km with meter marking The materials used in manufacture are
Coupling resistance cadmium-free and contain no silicone
acc. to different cross-sections Note and free from substances harmful to
max. 250 Ohm/km G = with GN-YE conductor the wetting properties of lacquers
Minimum bending radius **) The current carrying capacity for Tests
free-movement for outer : permanent operation at ambient temperature PVC self-extinguishing and flame retardant
up to 12 mm: 10x cable of 30C. For deviating ambient temperatures acc. to DIN VDE 0482-332-1-2,
> 12-20 mm: 15x cable the conversion factors should be used and DIN EN 60332-1-2, IEC 60332-1 (equivalent
> 20 mm: 20x cable for further see the indication in DIN VDE 0472 part 804 test method B)
fixed installation for outer : DIN VDE 0298 part 4. Meets EMC requirements acc. to
up to 12 mm: 5x cable AWG sizes are approximate equivalent EN 55011 and DIN VDE 0875 part 11
> 12-20 mm: 7,5x cable values. The actual cross-section is in mm.
> 20 mm: 10x cable
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
This TOPFLEX-EMV-2YSLCY-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings,
facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a
supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments, not
however for outdoor applications. Used in the automotive and food industries, environmental technology, packaging industry, machine tools. Handling
equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations
and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight approx.
mm approx.nF / approx.nF / Ohm/km Ohm/km in Amperes kg / km kg / km
km km
22084 4 G 1,5 10,1 70 110 18 95,0 230,0 16
22085 4 G 2,5 11,9 80 130 18 210 26 150,0 300,0 14
22086 4G4 13,6 90 150 11 210 34 235,0 485,0 12
22087 4G6 15,3 90 150 6 150 44 320,0 633,0 10
22088 4 G 10 19,4 120 200 7 180 61 533,0 863,0 8
22089 4 G 16 22,4 140 230 9 190 82 789,0 1291,0 6
22090 4 G 25 26,7 120 210 4 95 108 1236,0 1862,0 4
22091 4 G 35 29,3 150 260 3 85 135 1662,0 2611,0 2
22092 4 G 50 34,1 190 320 2 40 168 2345,0 2955,0 1
22093 4 G 70 39,0 190 320 2 45 207 3196,0 3953,0 2/0
22094 4 G 95 44,0 250 410 1 50 250 4316,0 5304,0 3/0
22095 4 G 120 48,7 292 5435,0 6604,0 4/0
22096 4 G 150 54,2 335 6394,0 7043,0 300 kcmil
22097 4 G 185 60,6 382 7639,0 8384,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

204
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-3 PLUS 2YSLCY-J for power supply connections


to frequency converters, double screened, 0,6/1kV, meter marking

D
Technical data Cable structure Properties
Special motor power supply cable for Bare copper-conductor, to Low mutual capacitance
frequency converters adapted to DIN VDE 0295 cl.5, fine-wire, Low coupling resistance for high
DIN VDE 0250 BS 6360 cl.5, IEC 60228 cl.5 electromagnetic compatibility
Temperature range Core insulation of polyethylene (PE) The minimum cross-section
flexing +5C to +70C Core identification BK, BN, GY of 0,75 meets the requirements
fixed installation -40C to +70C GN-YE conductor (divided into 3) of DIN EN 60204 part 1.
Nominal voltage U0/U 600/1000 V 3+3-core structure The 3 PLUS-construction of motor power
Max. operating voltage Cores stranded in concentric layers supply cables features a symmetrical 3-core
A.C. and 3-phase 700/1200 V 1. Screen with special aluminium film design, improved in terms of EMC
DC operation 900/1800 V 2. Tinned copper braided screen, characteristics comparing favorably with a
Test voltage 4000 V approx. 85% coverage 4-core version. The protective conductor
Insulation resistance Outer sheath of special PVC PE, divided into 3 is uniformly stranded in
min. 200 MOhm x km Sheath colour transparent the interstices. This enables an extremely
Coupling resistance with meter marking concentric structure.
acc. to different cross-sections Due to the optimal screening an
max. 250 Ohm/km Note interference-free operation of
Minimum bending radius **)The current carrying capacity for frequency converters is obtained
free-movement for outer : permanent operation at ambient temperature The materials used in manufacture are
up to 12 mm: 10x cable of 30C. For deviating ambient temperatures cadmium-free and contain no silicone
> 12-20 mm: 15x cable the conversion factors should be used and and free from substances harmful to
> 20 mm: 20x cable for further see the indication in the wetting properties of lacquers
fixed installation for outer : DIN VDE 0298 part 4. Tests
up to 12 mm: 5x cable AWG sizes are approximate equivalent PVC self-extinguishing and flame retardant
> 12-20 mm: 7,5x cable values. The actual cross-section is in mm. acc. to DIN VDE 0482-332-1-2,
> 20 mm: 10x cable DIN EN 60332-1-2, IEC 60332-1 (equivalent
Radiation-resistance DIN VDE 0472 part 804 test method B)
up to 80x106 cJ/kg (up to 80 Mrad) Meets EMC requirements acc. to
EN 55011 and DIN VDE 0875 part 11

Application
As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments
not however for outdoor applications. Used in the automotive and food industries, environmental technology, packaging industry, machine tools.
Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning
installations and similar applications. Installation in hazardous areas. This screened motor supply cable with low mutual capacitance of the single cores
because of the special PE core insulation and low screen capacitance enable a low-loss transmission of the power compared to PVC-sheathed connecting
cables. Due to the optimal screening an interference-free operation of frequency converters is obtained. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm at 1 MHz at 30 MHz with 3 loaded cores weight approx. kg / km
mm Ohm/km Ohm/km in Amperes kg / km
22368 3 x 1,5 + 3 G 0,25 9,2 18 86,0 140,0 16
22369 3 x 2,5 + 3 G 0,5 10,8 18 210 26 144,0 220,0 14
22370 3 x 4 + 3 G 0,75 12,3 11 210 34 224,0 323,0 12
22371 3 x 6 + 3 G 1,0 14,0 6 150 44 298,0 420,0 10
22372 3 x 10 + 3 G 1,5 17,6 7 180 61 491,0 615,0 8
22373 3 x 16 + 3 G 2,5 21,2 9 190 82 723,0 819,0 6
22374 3 x 25 + 3 G 4,0 24,5 4 95 108 1138,0 1325,0 4
22375 3 x 35 + 3 G 6,0 26,9 3 85 135 1535,0 1718,0 2
22376 3 x 50 + 3 G 10,0 32,5 2 40 168 2208,0 2399,0 1
22377 3 x 70 + 3 G 10,0 35,5 2 45 207 2871,0 3056,0 2/0
22378 3 x 95 + 3 G 16,0 40,1 1 50 250 3953,0 4162,0 3/0
22379 3 x 120 + 3 G 16,0 44,4 292 4836,0 5074,0 4/0
22380 3 x 150 + 3 G 25,0 49,3 335 5412,0 6128,0 300 kcmil
22381 3 x 185 + 3 G 35,0 55,1 382 6969,0 7189,0 350 kcmil
22382 3 x 240 + 3 G 42,5 60,0 453 8540,0 9540,0 500 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

205
Motor-, Servo and Feedback Cables

TOPFLEX -EMV-UV-2YSLCYK-J for power supply connections to


frequency converters, double screened, 0,6/1kV, meter marking

Technical data Cable structure Properties


Special motor power supply cable for Bare copper-conductor, to Low mutual capacitance
frequency converters adapted to DIN VDE 0295 cl.5, fine-wire, Low coupling resistance for high
DIN VDE 0250 BS 6360 cl.5, IEC 60228 cl.5 electromagnetic compatibility
Temperature range Core insulation of polyethylene (PE) UV-resitant
flexing -5C to +70C Core identificdation BN, BK, GY Outdoor application, possible for
fixed installation -40C to +70C GN-YE conductor installation in underground at 4G16 mm
Nominal voltage U0/U 600/1000 V Cores stranded in concentric layers This screened motor supply cable with
Max. operating voltage 1. Screen with special aluminium film low mutual capacitance of the single cores
A.C. and 3-phase 700/1200 V 2. Tinned copper braided screen, because of the special PE core insulation
DC operation 900/1800 V approx. 85% coverage and low screen capacitance enable a low-loss
Test voltage 4000 V Outer sheath of special PVC transmission of the power compared to
Insulation resistance Sheath colour black (RAL 9005) PVC-sheathed connecting cables
min. 200 MOhm x km with meter marking Due to the optimal screening an
Coupling resistance interference-free operation of
acc. to different cross-sections Note frequency converters is obtained
max. 250 Ohm/km **)The current carrying capacity for The materials used in manufacture are
Minimum bending radius permanent operation at ambient temperature cadmium-free and contain no silicone
free-movement for outer : of 30C. For deviating ambient temperatures and free from substances harmful to
up to 12 mm: 10x cable the conversion factors should be used and the wetting properties of lacquers
> 12-20 mm: 15x cable for further see the indication in Tests
> 20 mm: 20x cable DIN VDE 0298 part 4. PVC self-extinguishing and flame retardant
fixed installation for outer : acc. to DIN VDE 0482-332-1-2,
up to 12 mm: 5x cable DIN EN 60332-1-2, IEC 60332-1 (equivalent
> 12-20 mm: 7,5x cable DIN VDE 0472 part 804 test method B)
> 20 mm: 10x cable Meets EMC requirements acc. to
Radiation-resistance EN 55011 and DIN VDE 0875 part 11
up to 80x106 cJ/kg (up to 80 Mrad) AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This TOPFLEX-EMV-2YSLCYK-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings,
facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a
supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments and for
outdoor applications, possible for installation in underground at 4G16 mm. Used in the automotive and food industries, environmental technology,
packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators,
conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight approx.
mm approx.nF / approx.nF / Ohm/km Ohm/km in Amperes kg / km kg / km
km km
22234 4 G 1,5 10,1 70 110 18 95,0 230,0 16
22235 4 G 2,5 11,9 80 130 18 210 26 150,0 300,0 14
22236 4G4 13,6 90 150 11 210 34 235,0 485,0 12
22237 4G6 15,3 90 150 6 150 44 320,0 630,0 10
22238 4 G 10 19,4 120 200 7 180 61 533,0 860,0 8
22239 4 G 16 22,4 140 230 9 190 82 789,0 1290,0 6
22240 4 G 25 26,7 120 210 4 95 108 1236,0 1860,0 4
22241 4 G 35 29,3 150 260 3 85 135 1662,0 2610,0 2
22242 4 G 50 34,1 190 320 2 40 168 2345,0 2950,0 1
22243 4 G 70 39,0 190 320 2 45 207 3196,0 3950,0 2/0
22244 4 G 95 44,0 250 410 1 50 250 4316,0 5300,0 3/0
22245 4 G 120 48,7 292 5435,0 6600,0 4/0
22246 4 G 150 54,2 335 6394,0 7040,0 300 kcmil
22247 4 G 185 60,6 382 7639,0 8380,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

206
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J for power supply


connections to frequency converters, double screened, 0,6/1kV, meter marking

D
Technical data Cable structure Properties
Special motor power supply cable for Bare copper-conductor, to Low mutual capacitance
frequency converters adapted to DIN VDE 0295 cl.5, fine-wire, Low coupling resistance for high
DIN VDE 0250 BS 6360 cl.5, IEC 60228 cl.5 electromagnetic compatibility
Temperature range Core insulation of polyethylene (PE) Due to the optimal screening an
flexing -5C up to +70C Core identification BK, BN, GY interference-free operation of
fixed installation -40C up to +70C GN-YE conductor (divided into 3) frequency converters is obtained
Nominal voltage U0/U 600/1000 V 3+3 core design The 3 PLUS-construction of motor power
Max. operating voltage Cores stranded in concentric layers supply cables features a symmetrical 3-core
A.C. and 3-phase 700/1200 V 1. Screen with special aluminium film design, improved in terms of EMC
DC operation 900/1800 V 2. Tinned copper braided screen, characteristics comparing favorably with a
Test voltage 4000 V approx. 85% coverage 4-core version. The protective conductor
Insulation resistance Outer sheath of special PVC PE, divided into 3 is uniformly stranded in
min. 200 MOhm x km Sheath colour black (RAL 9005) the interstices. This enables an extremely
Coupling resistance with meter marking concentric structure
acc. to different cross-sections The minimum cross-section of
max. 250 Ohm/km Note 0,75 mm meets the requirements
Minimum bending radius **)The current carrying capacity for of DIN EN 60204 part 1
free-movement for outer : permanent operation at ambient temperature UV-resistant
up to 12 mm: 10x cable of 30C. For deviating ambient temperatures Outdoor application
> 12-20 mm: 15x cable the conversion factors should be used and This screened motor supply cable with
> 20 mm: 20x cable for further see the indication in low mutual capacitance of the single cores
fixed installation for outer : DIN VDE 0298 part 4. because of the special PE core insulation
up to 12 mm: 5x cable AWG sizes are approximate equivalent and low screen capacitance enable a low-loss
> 12-20 mm: 7,5x cable values. The actual cross-section is in mm. transmission of the power compared to
> 20 mm: 10x cable PVC-sheathed connecting cables
Radiation resistance The materials used in manufacture are
up to 80x106 cJ/kg (up to 80 Mrad) cadmium-free and contain no silicone
and free from substances harmful to
the wetting properties of lacquers
Tests
PVC self-extinguishing and flame retardant
acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Meets EMC requirements acc. to
EN 55011 and DIN VDE 0875 part 11

Application
As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments
and for outdoor applications, possible for installation in underground at 3x16+3G2,5 mm. Used in the automobile industry, food industry, environmental
engineering, packaging industry, toolmaking machinery, handling equipment, for SIMOVERT drivers, they are particularly suitable for use with industrial
pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Continuation

207
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J for power supply


connections to frequency converters, double screened, 0,6/1kV, meter marking
Part no. No.cores x Outer Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm at 1 MHz at 30 MHz with 3 loaded cores weight approx. kg / km
mm Ohm/km Ohm/km in Amperes kg / km
22673 3 x 1,5 + 3 G 0,25 9,2 18 86,0 140,0 16
22674 3 x 2,5 + 3 G 0,5 10,8 18 210 26 144,0 220,0 14
22675 3 x 4 + 3 G 0,75 12,3 11 210 34 224,0 323,0 12
22676 3 x 6 + 3 G 1,0 14,0 6 150 44 298,0 420,0 10
22677 3 x 10 + 3 G 1,5 17,6 7 180 61 491,0 615,0 8
22678 3 x 16 + 3 G 2,5 21,2 9 190 82 723,0 819,0 6
22679 3 x 25 + 3 G 4,0 24,5 4 95 108 1138,0 1325,0 4
22680 3 x 35 + 3 G 6,0 26,9 3 85 135 1535,0 1718,0 2
22681 3 x 50 + 3 G 10,0 32,5 2 40 168 2208,0 2399,0 1
22682 3 x 70 + 3 G 10,0 35,5 2 45 207 2871,0 3056,0 2/0
22683 3 x 95 + 3 G 16,0 40,1 1 50 250 3953,0 4162,0 3/0
22684 3 x 120 + 3 G 16,0 44,4 292 4836,0 5075,0 4/0
22685 3 x 150 + 3 G 25,0 49,3 335 5412,0 6128,0 300 kcmil
22686 3 x 185 + 3 G 35,0 55,1 382 6969,0 7189,0 350 kcmil
22687 3 x 240 + 3 G 42,5 60,0 453 8540,0 9540,0 500 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

208
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-UV-2XSLCYK-J for power supply connections to


frequency converters, double screened, higher current carrying capacity, 0,6/1kV, meter marking

D
Technical data Cable structure Properties
Special motor power supply cable for Bare copper-conductor, to Low mutual capacitance
frequency converters adapted to DIN VDE 0295 cl.5, fine-wire, Low coupling resistance for high
DIN VDE 0250 BS 6360 cl.5, IEC 60228 cl.5 electromagnetic compatibility
Temperature range Core insulation of cross-linked UV-resitant
flexing -5C to +90C polyethylene (XLPE) Outdoor application, possible for
fixed installation -40C to +90C Core identification BN, BK, GY installation in underground at 4G16 mm
Permissible operating temperature GN-YE conductor This screened motor supply cable with
at conductor +90C Cores stranded in concentric layers low mutual capacitance of the single cores
Nominal voltage U0/U 600/1000 V 1. Screen with special aluminium film because of the special XLPE core insulation
Max. operating voltage 2. Tinned copper braided screen, and low screen capacitance enable a low-loss
A.C. and 3-phase 700/1200 V approx. 85% coverage transmission of the power compared to
DC operation 900/1800 V Outer sheath of special PVC PE-sheathed connecting cables
Test voltage 4000 V Sheath colour black (RAL 9005) Due to the optimal screening an
Insulation resistance with meter marking interference-free operation of
min. 200 MOhm x km frequency converters is obtained
Coupling resistance Note The materials used in manufacture are
acc. to different cross-sections **)The current carrying capacity for cadmium-free and contain no silicone
max. 250 Ohm/km permanent operation at ambient temperature and free from substances harmful to
Minimum bending radius of 30C. For deviating ambient temperatures the wetting properties of lacquers
free-movement for outer : the conversion factors should be used and Tests
up to 12 mm: 10x cable for further see the indication in self-extinguishing and flame retardant
> 12-20 mm: 15x cable DIN VDE 0298 part 4. acc. to DIN VDE 0482-332-1-2,
> 20 mm: 20x cable AWG sizes are approximate equivalent DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation for outer : values. The actual cross-section is in mm. DIN VDE 0472 part 804 test method B)
up to 12 mm: 5x cable Meets EMC requirements acc. to
> 12-20 mm: 7,5x cable EN 55011 and DIN VDE 0875 part 11
> 20 mm: 10x cable
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
This TOPFLEX-EMV-UV-2XSLCYK-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and
buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings.
Respecting the permissible operating temperature at the conductor of +90 C permits a higher current carrying capacity than PE insulated power
distribution cables. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and
wet environments and for outdoor applications, possible for installation in underground at 4G16 mm. Used in the automotive and food industries,
environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with
industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight approx.
mm approx.nF / approx.nF / Ohm/km Ohm/km in Amperes kg / km kg / km
km km
24489 4 G 1,5 10,1 70 110 23 95,0 230,0 16
24490 4 G 2,5 11,2 80 130 18 210 32 150,0 300,0 14
24491 4G4 12,8 90 150 11 210 42 235,0 485,0 12
24492 4G6 14,9 90 150 6 150 54 320,0 630,0 10
24493 4 G 10 17,7 120 200 7 180 75 533,0 860,0 8
24494 4 G 16 20,9 140 230 9 190 100 789,0 1290,0 6

Continuation

209
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-UV-2XSLCYK-J for power supply connections to


frequency converters, double screened, higher current carrying capacity, 0,6/1kV, meter marking
Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight approx.
mm approx.nF / approx.nF / Ohm/km Ohm/km in Amperes kg / km kg / km
km km
24495 4 G 25 25,3 120 210 4 95 127 1236,0 1860,0 4
24496 4 G 35 28,0 150 260 3 85 158 1662,0 2610,0 2
24497 4 G 50 32,3 190 320 2 40 192 2345,0 2950,0 1
24498 4 G 70 37,6 190 320 2 45 246 3196,0 3950,0 2/0
24499 4 G 95 41,6 250 410 1 50 298 4316,0 5300,0 3/0
24500 4 G 120 44,8 346 5435,0 6600,0 4/0
24506 4 G 150 52,3 399 6394,0 7040,0 300 kcmil
24507 4 G 185 58,7 456 7639,0 8380,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

210
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-UV-3 PLUS 2XSLCYK-J for power supply


connections to frequency converters, double screened, higher current carrying capacity, 0,6/1kV,
meter marking

Technical data Cable structure Properties


Special motor power supply cable for Bare copper-conductor, to Low mutual capacitance
frequency converters adapted to DIN VDE 0295 cl.5, fine-wire, Low coupling resistance for high
DIN VDE 0250 BS 6360 cl.5, IEC 60228 cl.5 electromagnetic compatibility
Temperature range Core insulation of cross-linked Due to the optimal screening an
flexing -5C to +90C polyethylene (XLPE) interference-free operation of
fixed installation -40C to +90C Core identification BK, BN, GY frequency converters is obtained
Permissible operating temperature GN-YE conductor (divided into 3) The 3 PLUS-construction of motor power
at conductor +90C 3+3 core design supply cables features a symmetrical 3-core
Nominal voltage U0/U 600/1000 V Cores stranded in concentric layers design, improved in terms of EMC
Max. operating voltage 1. Screen with special aluminium film characteristics comparing favorably with a
A.C. and 3-phase 700/1200 V 2. Tinned copper braided screen, 4-core version. The protective conductor
DC operation 900/1800 V approx. 85% coverage PE, divided into 3 is uniformly stranded in
Test voltage 4000 V Outer sheath of special PVC the interstices. This enables an extremely
Insulation resistance Sheath colour black (RAL 9005) concentric structure.
min. 200 MOhm x km with meter marking The minimum cross-section of
Coupling resistance 0,75 mm meets the requirements
acc. to different cross-sections Note of DIN EN 60204 part 1
max. 250 Ohm/km **)The current carrying capacity for UV-resistant
Minimum bending radius permanent operation at ambient temperature Outdoor application, possible for installation
free-movement for outer : of 30C. For deviating ambient temperatures in undergraound at 3x16+3G2,5 mm
up to 12 mm: 10x cable the conversion factors should be used and This screened motor supply cable with
> 12-20 mm: 15x cable for further see the indication in low mutual capacitance of the single cores
> 20 mm: 20x cable DIN VDE 0298 part 4. because of the special XLPE core insulation
fixed installation for outer : AWG sizes are approximate equivalent and low screen capacitance enable a low-loss
up to 12 mm: 5x cable values. The actual cross-section is in mm. transmission of the power compared to
> 12-20 mm: 7,5x cable PE-sheathed connecting cables
> 20 mm: 10x cable The materials used in manufacture are
Radiation resistance cadmium-free and contain no silicone
up to 80x106 cJ/kg (up to 80 Mrad) and free from substances harmful to
the wetting properties of lacquers
Tests
self-extinguishing and flame retardant
acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Meets EMC requirements acc. to
EN 55011 and DIN VDE 0875 part 11

Application
As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments
and for outdoor applications, possible for installation in underground at 3x16+3G2,5 mm. Respecting the permissible operating temperature at the
conductor of +90 C permits a higher current carrying capacity than PE insulated power distribution cables. Used in the automobile industry, food
industry, environmental engineering, packaging industry, toolmaking machinery, handling equipment, for SIMOVERT drivers, they are particularly
suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous
areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Continuation

211
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-UV-3 PLUS 2XSLCYK-J for power supply


connections to frequency converters, double screened, higher current carrying capacity, 0,6/1kV,
meter marking
Part no. No.cores x Outer Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm at 1 MHz at 30 MHz with 3 loaded cores weight approx. kg / km
mm Ohm/km Ohm/km in Amperes kg / km
24508 3 x 1,5 + 3 G 0,25 9,2 23 86,0 140,0 16
24509 3 x 2,5 + 3 G 0,5 10,8 18 210 32 144,0 220,0 14
24510 3 x 4 + 3 G 0,75 12,3 11 210 42 224,0 323,0 12
24511 3 x 6 + 3 G 1,0 14,0 6 150 54 298,0 420,0 10
24512 3 x 10 + 3 G 1,5 17,6 7 180 75 491,0 615,0 8
24513 3 x 16 + 3 G 2,5 20,4 9 190 100 723,0 819,0 6
24514 3 x 25 + 3 G 4,0 23,2 4 95 127 1138,0 1325,0 4
24515 3 x 35 + 3 G 6,0 26,1 3 85 158 1535,0 1718,0 2
24516 3 x 50 + 3 G 10,0 30,8 2 40 192 2208,0 2399,0 2
24517 3 x 70 + 3 G 10,0 34,2 2 45 246 2871,0 3056,0 2/0
24518 3 x 95 + 3 G 16,0 37,8 1 50 298 3953,0 4162,0 3/0
24519 3 x 120 + 3 G 16,0 42,6 346 4836,0 5075,0 4/0
24520 3 x 150 + 3 G 25,0 47,5 399 5412,0 6128,0 300 kcmil
24521 3 x 185 + 3 G 35,0 53,4 456 6969,0 7189,0 350 kcmil
24587 3 x 240 + 3 G 42,5 58,7 538 8540,0 9540,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

212
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-UV-2XSLCH-J for power supply connections to frequency


converters, halogen-free, double screened, higher current carrying capacity, 0,6/1kV, meter marking

D
Technical data Cable structure Properties
Special motor power supply cable for Bare copper, fine wire conductor to halogen-free
frequency converters adapted to DIN VDE 0295 cl.5, BS 6360 cl.5, Low mutual capacitance
DIN VDE 0250 IEC 60228 cl.5 Low coupling resistance for high
Temperature range Core insulation of cross-linked electromagnetic compatibility
flexing -5C to +90C polyethylene (XLPE) This screened motor supply cable with
fixed installation -40C to +90C Core cidentification: BN, BL, GY low mutual capacitance of the single cores
Permissible operating temperature GN-YE conductor because of the special XLPE core insulation
at conductor +90C Cores stranded in concentric layers and low screen capacitance enable a low-loss
Nominal voltage U0/U 600/1000 V 1. Screen with special aluminium film transmission of the power compared to
Max. operating voltage 2. Tinned copper braided screen, PE-sheathed connecting cables
A.C. and 3-phase 700/1200 V approx. 85% coverage Due to the optimal screening an
DC operation 900/1800 V Outer sheath of special polyolefin compound interference-free operation of frequency
Test voltage 4000 V Sheath colour black (RAL 9005) converters is obtained
Insulation resistance with meter marking The materials used in manufacture are
min. 200 MOhm x km cadmium-free and contain no silicone
Coupling resistance Note and free from substances harmful to
acc. to different cross-sections The current carrying capacity for
**) the wetting properties of lacquers
max. 250 Ohm/km permanent operation at ambient temperature Tests
Minimum bending radius of 30C. For deviating ambient temperatures self-extinguishing and flame retardant
free-movement for outer : the conversion factors should be used and acc. to DIN VDE 0482-332-1-2,
up to 12 mm: 10x cable for further see the indication in DIN EN 60332-1-2, IEC 60332-1 (equivalent
> 12-20 mm: 15x cable DIN VDE 0298 part 4. DIN VDE 0472 part 804 test method B)
> 20 mm: 20x cable AWG sizes are approximate equivalent Meets EMC requirements acc. to
fixed installation for outer : values. The actual cross-section is in mm. EN 55011 and DIN VDE 0875 part 11
up to 12 mm: 5x cable
> 12-20 mm: 7,5x cable
> 20 mm: 10x cable
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
This TOPFLEX-EMV-UV-2XSLCH-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and
buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings.
Respecting the permissible operating temperature at the conductor of +90 C permits a higher current carrying capacity than PE insulated power
distribution cables. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and
wet environments. These cables are suitable for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit
all precautions must be taken that no accumulation of water can occur in the pipes. Used in the automotive and food industries, environmental
technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps,
ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Continuation

213
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-UV-2XSLCH-J for power supply connections to frequency


converters, halogen-free, double screened, higher current carrying capacity, 0,6/1kV, meter marking
Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight approx.
mm approx.nF / approx.nF / Ohm/km Ohm/km in Amperes kg / km kg / km
km km
24522 4 G 1,5 10,1 70 110 23 95,0 230,0 16
24523 4 G 2,5 11,2 80 130 18 210 32 150,0 300,0 14
24524 4G4 12,8 90 150 11 210 42 235,0 485,0 12
24525 4G6 14,9 90 150 6 150 54 320,0 630,0 10
24526 4 G 10 17,7 120 200 7 180 75 533,0 860,0 8
24527 4 G 16 20,9 140 230 9 190 100 789,0 1290,0 6
24528 4 G 25 25,3 120 210 4 95 127 1236,0 1860,0 4
24529 4 G 35 28,0 150 260 3 85 168 1662,0 2610,0 2
24530 4 G 50 32,3 190 320 2 40 192 2345,0 2950,0 1
24531 4 G 70 37,6 190 320 2 45 246 3196,0 3950,0 2/0
24532 4 G 95 41,6 250 410 1 50 298 4316,0 5300,0 3/0
24533 4 G 120 44,8 346 5435,0 6600,0 4/0
24534 4 G 150 52,3 399 6394,0 7040,0 300 kcmil
24535 4 G 185 58,7 456 7639,0 8380,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

214
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-UV-3 PLUS 2XSLCH-J for power supply connections


to frequency converters, halogen-free, double screened, higher current carrying capacity, 0,6/1kV,
meter marking

Technical data Cable structure Properties


Special motor power supply cable for Bare copper-conductor, to halogen-free
frequency converters adapted to DIN VDE 0295 cl.5, fine-wire, Low mutual capacitance
DIN VDE 0250 BS 6360 cl.5, IEC 60228 cl.5 Low coupling resistance for high
Temperature range Core insulation of cross-linked electromagnetic compatibility
flexing -5C to +90C polyethylene (XLPE) Due to the optimal screening an
fixed installation -40C to +90C Core identification BK, BN, GY interference-free operation of frequency
Permissible operating temperature GN-YE conductor (divided into 3) converters is obtained
at conductor +90C 3+3 core design The 3 PLUS-construction of motor power
Nominal voltage U0/U 600/1000 V Cores stranded in concentric layers supply cables features a symmetrical 3-core
Max. operating voltage 1. Screen with special aluminium film design, improved in terms of EMC
A.C. and 3-phase 700/1200 V 2. Tinned copper braided screen, characteristics comparing favorably with a
DC operation 900/1800 V approx. 85% coverage 4-core version. The protective conductor
Test voltage 4000 V Outer sheath special polyolefin compound PE, divided into 3 is uniformly stranded in
Insulation resistance Sheath colour black (RAL 9005) the interstices. This enables an extremely
min. 200 MOhm x km with meter marking concentric structure
Coupling resistance The minimum cross-section of
acc. to different cross-sections Note 0,75 mm meets the requirements
max. 250 Ohm/km **)The current carrying capacity for of DIN EN 60204 part 1
Minimum bending radius permanent operation at ambient temperature This screened motor supply cable with
free-movement for outer : of 30C. For deviating ambient temperatures low mutual capacitance of the single cores
up to 12 mm: 10x cable the conversion factors should be used and because of the special XLPE core insulation
> 12-20 mm: 15x cable for further see the indication in and low screen capacitance enable a low-loss
> 20 mm: 20x cable DIN VDE 0298 part 4. transmission of the power compared to
fixed installation for outer : AWG sizes are approximate equivalent PE-sheathed connecting cables
up to 12 mm: 5x cable values. The actual cross-section is in mm. The materials used in manufacture are
> 12-20 mm: 7,5x cable cadmium-free and contain no silicone
> 20 mm: 10x cable and free from substances harmful to
Radiation resistance the wetting properties of lacquers
up to 80x106 cJ/kg (up to 80 Mrad) Tests
self-extinguishing and flame retardant
acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Meets EMC requirements acc. to
EN 55011 and DIN VDE 0875 part 11

Application
As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments.
These cables are suitable for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must
be taken that no accumulation of water can occur in the pipes. Respecting the permissible operating temperature at the conductor of +90 C permits
a higher current carrying capacity than PE insulated power distribution cables. Used in the automobile industry, food industry, environmental engineering,
packaging industry, toolmaking machinery, handling equipment, for SIMOVERT drivers, they are particularly suitable for use with industrial pumps,
ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Continuation

215
Motor-, Servo and Feedback Cables

TOPFLEX-EMV-UV-3 PLUS 2XSLCH-J for power supply connections


to frequency converters, halogen-free, double screened, higher current carrying capacity, 0,6/1kV,
meter marking
Part no. No.cores x Outer Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm at 1 MHz at 30 MHz with 3 loaded cores weight approx. kg / km
mm Ohm/km Ohm/km in Amperes kg / km
24536 3 x 1,5 + 3 G 0,25 9,2 23 86,0 140,0 16
24537 3 x 2,5 + 3 G 0,5 10,8 18 210 32 144,0 220,0 14
24538 3 x 4 + 3 G 0,75 12,3 11 210 42 224,0 323,0 10
24539 3 x 6 + 3 G 1,0 14,0 6 150 54 298,0 420,0 10
24540 3 x 10 + 3 G 1,5 17,6 7 180 75 491,0 615,0 10
24541 3 x 16 + 3 G 2,5 20,4 9 190 100 723,0 819,0 6
24542 3 x 25 + 3 G 4,0 23,2 4 95 127 1138,0 1325,0 10
24543 3 x 35 + 3 G 6,0 26,1 3 85 158 1535,0 1718,0 2
24544 3 x 50 + 3 G 10,0 30,8 2 40 192 2208,0 2399,0 2
24545 3 x 70 + 3 G 10,0 34,2 2 45 246 2871,0 3056,0 2/0
24546 3 x 95 + 3 G 16,0 37,8 1 50 298 3953,0 4162,0 3/0
24583 3 x 120 + 3 G 16,0 42,6 346 4836,0 5075,0 4/0
24584 3 x 150 + 3 G 25,0 47,5 399 5412,0 6128,0 300 kcmil
24585 3 x 185 + 3 G 35,0 53,4 456 6969,0 7189,0 350 kcmil
24586 3 x 240 + 3 G 42,5 58,7 538 8540,0 9540,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RD01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

216
Motor-, Servo and Feedback Cables

TOPFLEX Motor 109 low capacitance power supply cable 0,6/1kV, increased
ampacity, halogen-free, meter marking

D
Technical data Cable structure Properties
Special motor power supply cable for Bare copper-conductor, to Special polymerinsulation ensures low
frequency converters DIN VDE 0295 cl.5, fine-wire, dielectric losses, a dual voltage resistance,
Temperature range BS 6360 cl.5, IEC 60228 cl.5 longer service life and low - interference
flexing -5C to +70C Core insualtion of special Polymer shield, and increased current carrying
fixed installation -40C to +80C Core identification to DIN VDE 0293-308 capacity
Permissible operating temperature - up to 5 cores coloured Low coupling resistance for high
at conductor +90C - from 7 cores, black with continuous electromagnetic compatibility
Nominal voltage U0/U 600/1000 V white numbering UV-resistant
Max. operating voltage GN-YE conductor Outdoor application
A.C. and 3-phase 700/1200 V Cores stranded in concentric layers This screened motor supply cable with
DC operation 900/1800 V 1. Screen with special aluminium film low mutual capacitance of the single
Test voltage 2500 V 2. Tinned copper braided screen, cores because of the special Polymer
Insulation resistance approx. 80% coverage core insulation and low screen capacitance
min. 200 MOhm x km Outer sheath of special PUR enable a low-loss transmission of the
Coupling resistance Sheath colour orange (RAL 2003) power compared to PVC-sheathed
acc. to different cross-sections with meter marking connecting cables
max. 250 Ohm/km Due to the optimal screening an
Mutual capacitance interference-free operation of frequency
acc. to different cross-sections converters is obtained
core/core 70 to 250 nF/km Design acc. to the requirements of
core/screen 110 to 410 nF/km VdS 3501:2006-04
Minimum bending radius The materials used in manufacture are
free-movement for outer : cadmium-free and contain no silicone
up to 12 mm: 10x cable and free from substances harmful to
> 12-20 mm: 15x cable the wetting properties of lacquers
> 20 mm: 20x cable Tests
fixed installation for outer : Low mutual capacitance, test acc. to
up to 12 mm: 5x cable DIN VDE 0472 part 504, test method B
> 12-20 mm: 7,5x cable Meets EMC requirements acc. to
> 20 mm: 10x cable EN 55011 and DIN VDE 0875 part 11
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad) Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings, facilities with units and
operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a supply and connecting
cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments and for outdoor applications.
Used in the automotive and food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives,
they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
22724 3 G 1,5 9,4 72,0 200,0 16 22715 5G4 15,4 321,0 567,0 12
22707 4 G 1,5 10,4 95,0 230,0 16 22716 7G4 18,2 352,0 603,0 12
22708 5 G 1,5 11,2 117,0 258,0 16 22717 4G6 15,2 320,0 633,0 10
22709 7 G 1,5 13,2 148,0 281,0 16 22718 5G6 16,8 439,0 679,0 10
22710 3 G 2,5 11,2 137,0 270,0 14 22719 7G6 20,0 501,0 771,0 10
22711 4 G 2,5 12,5 150,0 300,0 14 22720 4 G 10 19,5 533,0 860,0 8
22712 5 G 2,5 13,5 200,0 352,0 14 22721 5 G 10 21,6 711,0 1029,0 8
22713 7 G 2,5 16,0 230,0 473,0 14 22722 4 G 16 23,1 789,0 1290,0 6
22714 4G4 14,2 235,0 485,0 12 22723 4 G 25 27,1 1236,0 1862,0 4

Dimensions and specifications may be changed without prior notice. (RD01)

217
HEAT-RESISTANT CABLES

3
in

E
VD eld 29
ng

x
xe
ex

VD
ed
U

R/ shi E 0
xi
- fi
- fl

./
0 /

le

ed
i

no
H A ed / VD
-f

-f
U
C)

C)

ge

us

us

CS REG
e n es /
(

e
lta

di

di

se
re

re

t
fre

ut tan

r
n
ra

ra

co
tu

tu

u
vo

E
ai
n-

or
sis
ra

ra

A
d
ch
al

ge
in

in
pe

pe

re
do
re
in

ge
nd

nd

ag
lo

lo

re
V-
m

L/
om

Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
N
Heat-resistant cables

HELUTHERM 120 -5 to +105 -30 to +105 300/500 7.5x 4x X X 220

HELUTHERM 145 MULTI



-35 to +120 -55 to +145 300/500 8x 4x X X X X 221 E
SiHF -60 to +180 300/500 7.5x 4x X X X 223

THERMFLEX 180 EWKF -25 to +180 -60 to +180 300/500 7.5x 4x X X X 225

H05SS-F / H05SST-F -60 to +180 300/500 7.5x 4x X X 226

HELUFLON-FEP-6Y -100 to +205 600 15x 4x X X 227

MULTITHERM 400 -60 to +400 500 5x X X 229

HELUTHERM 145 MULTI-C -35 to +120 -55 to +145 300/500 8x 4x X X X X 230

SiHF-C-Si -60 to +180 300/500 10x 5x X X X X 232

THERMFLEX 180 EWKF-C -25 to +180 -60 to +180 300/500 10x 5x X X X X 234

SiHF/GL-P -60 to +180 300/500 10x 5x X X X X 235

MULTITHERM 400 -ES -60 to +400 500 5x X X X 236

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

219
Heat resistant Cables

HELUTHERM 120 flexible, heat-resistant (+105C), meter marking

Technical data Cable structure Properties


Special PVC cable with increased Bare copper-conductor, to The materials used in manufacture are
heat-resistance adapted to DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN VDE 0285-525-2-11 / BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
DIN EN 50525-2-11 Core insualtion of special PVC the wetting properties of lacquers
0,5-0,75 mm acc. to IEC 60227/56 compound type TI3 to Tests
1,0-2,5 mm acc. to IEC 60227/57 DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
Temperature range Core identification to DIN VDE 0293-308 acc. to DIN VDE 0482-332-1-2,
flexing -5C to +105C - up to 5 cores coloured DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation -30C to +105C - from 6 cores, black with continuous DIN VDE 0472 part 804 test method B)
(for short time +120C) white numbering
Nominal voltage GN-YE conductor, 3 cores and above Note
0,5-1 mm U0/U 300/500 V in the outer layer G = with green-yellow conductor
from 1,5 mm U0/U 450/750 V Cores stranded in layers with x = without green-yellow conductor
Spark-test 6000 V optimal lay-length AWG sizes are approximate equivalent
Test voltage 2000 V Outer sheath of special PVC, heat- values. The actual cross-section is in mm.
Breakdown voltage min. 4000 V resistant compound type TM3 to On request
Insulation resistance DIN VDE 0207-363-4-1 / DIN EN HELUTHERM 120 H03V2V2-F
min. 20 MOhm x km 50363-4-1 HELUTHERM 120 H05V2V2-F
Minimum bending radius Outer sheath black (RAL 9005), HELUTHERM 120 (H)05V2V2-F
flexing 7,5x cable also available in other colours on request
fixed installation 4x cable with meter marking
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
Therm cables are ideal for use in machines, appliances or motors which are subject to direct contact with high temperatures (e. g. varnishing machines
and drying towers etc.). For application in dry, moist and wet rooms and in open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24002 2 x 0,5 5,0 9,6 40,0 20 24030 2 x 1,5 7,4 29,0 77,0 16
24003 3 G 0,5 5,3 14,4 50,0 20 24031 3 G 1,5 8,1 43,0 97,0 16
24004 4 G 0,5 5,8 19,2 60,0 20 24032 4 G 1,5 9,0 58,0 122,0 16
24005 5 G 0,5 6,7 24,0 70,0 20 24033 5 G 1,5 10,0 72,0 143,0 16
24006 7 G 0,5 8,8 33,6 90,0 20 24034 7 G 1,5 11,9 101,0 179,0 16
24007 12 G 0,5 11,1 58,0 140,0 20 24035 12 G 1,5 14,5 173,0 310,0 16
24008 18 G 0,5 12,9 86,0 170,0 20 24036 18 G 1,5 17,4 259,0 460,0 16
24009 25 G 0,5 15,8 101,0 250,0 20 24037 25 G 1,5 21,3 360,0 650,0 16
24011 2 x 0,75 6,2 14,4 52,0 19 24039 2 x 2,5 9,3 48,0 120,0 14
24012 3 G 0,75 6,6 21,6 61,0 19 24046 3 G 2,5 10,1 72,0 150,0 14
24013 4 G 0,75 7,1 29,0 75,0 19 24040 4 G 2,5 11,0 96,0 200,0 14
24014 5 G 0,75 8,0 36,0 94,0 19 24041 5 G 2,5 12,3 120,0 250,0 14
24015 7 G 0,75 9,5 50,0 112,0 19 24042 7 G 2,5 14,6 168,0 310,0 14
24016 12 G 0,75 11,6 86,0 180,0 19 24044 2x4 10,6 77,0 180,0 12
24017 18 G 0,75 13,9 130,0 270,0 19 24291 3G4 11,5 115,0 220,0 12
24018 25 G 0,75 16,9 180,0 380,0 19 24045 4G4 12,5 154,0 300,0 12
24019 1x1 6,0 9,6 50,0 18 24292 5G4 15,1 192,0 360,0 12
24020 2x1 6,5 19,2 60,0 18
24021 3G1 6,9 29,0 73,0 18
24022 4G1 7,7 38,0 88,0 18
24023 5G1 8,4 48,0 110,0 18
24024 6G1 9,3 58,0 121,0 18
24025 7G1 10,0 67,0 130,0 18
24026 12 G 1 12,5 115,0 223,0 18
24027 18 G 1 14,7 173,0 350,0 18
24028 25 G 1 17,8 240,0 485,0 18

Dimensions and specifications may be changed without prior notice. (RE01)

220
Heat resistant Cables

HELUTHERM 145 MULTI flexible, cross-linked, halogen-free,


meter marking

Technical data
Halogen-free control and connecting cable
Cable structure
Tinned Cu wires, acc. to
Properties
Reduced flame propagation
E
with increased heat resistance DIN VDE 0295 cl.5, BS 6360 cl.5 Good abrasion and notch resistance
Temperature range and IEC 60228 cl. 5 Good resistance to oils and weathering
flexing -35C to +120C Core insulation of halogen-free, Resistant to UV radiation and ozone
fixed installation -55C to +145C cross-linked polyolefin-copolymer Resistant to soldering temperatures
in short-circuit +250C Core identification to DIN VDE 0293-308 Thermal class B
Nominal voltage - for 2 cores BN, BU Are resistant to melting, even when in
up to 1,0 mm U0/U 300/500 V - up to 5 cores coloured contact with a soldering iron at
from 1,5 mm U0/U 450/750 V - from 6 cores, black with continuous temperatures of between 300C and
with protected fixed installation white numbering 380C, because of the cross-linking for
from 1,5 mm U0/U 600/1000 V also available in other colours on request the insulation material
Test voltage 3000 V GN-YE conductor, 3 cores and above The materials used in manufacture are
Minimum bending radius Cores stranded in layers with cadmium-free and contain no silicone
in operation 8x cable optimal lay-length and free from substances harmful to
fixed installation 4x cable Fleece wrapping the wetting properties of lacquers
Caloric load values Outer sheath of halogenfree, Tests
see Technical Informations cross-linked Polyolefin-Copolymer Flame test (unit flame test) acc. to
Power ratings table Sheath colour black DIN VDE 0482-332-3-22, BS 4066 part 3,
see Technical Informations also available in other colours on request DIN EN 60332-3-22, IEC 60332-3-22
Approval with meter marking (previously DIN VDE 0472
Germanischer Lloyd part 804 test method C)
Note Flame test (cable) acc. to
G = with green-yellow conductor DIN VDE 0482-332-1-2, DIN EN 60332-1-2,
x = without green-yellow conductor IEC 60332-1-2 (equivalent DIN VDE 0472
AWG sizes are approximate equivalent part 804 test method B)
values. The actual cross-section is in mm. Corrosiveness of combustion gases
screened analogue type: acc. to DIN VDE 0482 part 267,
HELUTHERM 145 MULTI-C, DIN EN 50267-2-2, IEC 60754-2
confer page 230 (equivalent DIN VDE 0472 part 813)
Halogen-free
acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density
acc. to DIN VDE 0482 part 1034-1+2,
DIN EN 61034-1+2, IEC 61034-1+2,
BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Application
These halogen-free, cross-linked and temperature resistant wiring and control cables with enhanced fire-behaviour properties are used for wiring up
the lighting fixtures, heaters, electric machines (temperature class B), switching systems and distribution switchboards. A very long service life is also
given on account of their excellent high-temperature stability. These cables exhibit good resistance to weathering as well as being very stable to
temperature, moisture, ozone and UV radiation. These cables are therefore mainly used for traffic control systems and diverse outdoor applications.
The development of smoke is low and no corrosive gases are liberated during combustion of these halogen-free cables in case of fire. The risk of toxic
fumes is considerably less in the event of fire because the coloric load values is lower. Precious time can thus be won for a disciplined evacuation, and
unnecessary loss of life can be prevented. The extent of the damage to costly control and monitoring systems and the concrete and steel structures
of buildings and plant due to fire is reduced by this. Injuries to persons and damage to materials can be prevented. A lower conductor cross-section
is possible in certain circumstances because of the high thermal load and thus savings in the space and weight required can be made. These wiring
and control cables provide a significant contribution in safety engineering and environmental protection.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
53376 1 x 0,25 2,9 2,4 11,4 24 53381 6 G 0,25 6,5 14,4 58,0 24
52630 1 G 0,25 2,9 2,4 11,4 24 53382 7 G 0,25 6,9 16,8 64,0 24
53377 2 x 0,25 4,6 4,8 28,7 24 53383 8 G 0,25 7,3 19,2 71,0 24
53378 3 G 0,25 4,9 7,2 33,7 24 53384 10 G 0,25 8,1 24,0 84,0 24
53379 4 G 0,25 5,5 9,6 41,8 24 53385 12 G 0,25 8,1 28,8 90,0 24
53380 5 G 0,25 5,8 12,0 47,0 24 53386 14 G 0,25 8,6 33,6 102,0 24

Continuation

221
Heat resistant Cables

HELUTHERM 145 MULTI flexible, cross-linked, halogen-free,


meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
53387 16 G 0,25 8,9 38,4 114,0 24 53468 30 G 1,5 21,8 432,0 796,0 16
53388 19 G 0,25 10,1 45,6 132,0 24 53469 33 G 1,5 22,6 475,2 880,0 16
53389 21 G 0,25 10,5 50,4 145,0 24 53470 37 G 1,5 24,8 532,8 1026,0 16
52631 1 G 0,5 3,2 4,8 15,7 20 52635 1 G 2,5 5,0 24,0 46,9 14
53391 1 x 0,5 3,2 4,8 15,7 20 53471 1 x 2,5 5,0 24,0 46,9 14
53392 2 x 0,5 5,1 9,6 39,6 20 53472 2 x 2,5 9,0 48,0 99,0 14
53393 3 G 0,5 5,5 14,4 48,1 20 53473 3 G 2,5 9,8 72,0 140,0 14
53394 4 G 0,5 5,9 19,2 51,0 20 53474 4 G 2,5 10,8 96,0 183,0 14
53395 5 G 0,5 6,7 24,0 64,0 20 53475 5 G 2,5 12,0 120,0 231,0 14
53396 6 G 0,5 7,1 28,8 74,0 20 53476 6 G 2,5 13,2 144,0 280,0 14
53397 7 G 0,5 7,8 33,6 88,0 20 53477 7 G 2,5 14,6 168,0 336,0 14
53398 8 G 0,5 8,6 38,4 102,0 20 53478 8 G 2,5 15,7 192,0 397,0 14
53399 10 G 0,5 9,4 48,0 123,0 20 53479 10 G 2,5 17,7 240,0 460,0 14
53400 12 G 0,5 9,4 57,6 135,0 20 53480 12 G 2,5 18,7 288,0 500,0 14
53401 14 G 0,5 10,0 67,2 153,0 20 53481 14 G 2,5 19,0 336,0 593,0 14
53402 16 G 0,5 10,7 76,8 176,0 20 53482 16 G 2,5 20,1 384,0 675,0 14
53403 19 G 0,5 12,4 91,2 213,0 20 53483 19 G 2,5 20,7 456,0 835,0 14
53404 21 G 0,5 13,0 100,8 234,0 20 53484 21 G 2,5 23,7 504,0 939,0 14
53405 24 G 0,5 14,0 115,2 263,0 20 53485 24 G 2,5 25,8 576,0 1047,0 14
53406 25 G 0,5 14,0 120,0 269,0 20 53486 25 G 2,5 25,8 600,0 1067,0 14
53407 27 G 0,5 14,0 129,6 280,0 20 53487 27 G 2,5 25,8 648,0 1107,0 14
53408 30 G 0,5 15,0 144,0 311,0 20 53488 30 G 2,5 26,7 720,0 1219,0 14
53409 33 G 0,5 15,0 158,4 343,0 20 53489 33 G 2,5 28,0 792,0 1349,0 14
53410 37 G 0,5 17,0 177,6 392,0 20 53490 37 G 2,5 30,6 888,0 1565,0 14
52632 1 G 0,75 3,5 7,2 19,8 19 52636 1G4 5,6 38,4 96,0 12
53411 1 x 0,75 3,5 7,2 19,8 19 53491 1x4 5,6 38,4 96,0 12
53412 2 x 0,75 5,9 14,4 40,0 19 53492 2x4 10,2 76,8 159,0 12
53413 3 G 0,75 6,2 21,6 53,0 19 53493 3G4 10,9 115,2 197,0 12
53414 4 G 0,75 6,9 28,8 69,0 19 53494 4G4 12,2 153,6 260,0 12
53415 5 G 0,75 7,7 36,0 86,0 19 53495 5G4 13,5 192,0 329,0 12
53416 6 G 0,75 8,3 43,2 101,0 19 53496 6G4 14,9 230,4 398,0 12
53417 7 G 0,75 9,1 50,4 117,0 19 53497 7G4 16,4 268,8 478,0 12
53418 8 G 0,75 10,2 57,6 140,0 19 53498 8G4 17,6 307,2 553,0 12
53419 10 G 0,75 11,1 72,0 167,0 19 53499 10 G 4 20,1 384,0 663,0 12
53420 12 G 0,75 11,1 86,4 183,0 19 53500 12 G 4 20,1 460,8 725,0 12
53421 14 G 0,75 11,7 100,8 212,0 19 53501 14 G 4 21,5 537,6 797,0 12
53422 16 G 0,75 12,5 115,2 239,0 19 52637 1G6 6,1 57,6 108,0 10
53423 19 G 0,75 14,0 136,8 290,0 19 53502 1x6 6,1 57,6 108,0 10
53424 21 G 0,75 15,0 151,2 323,0 19 53503 2x6 11,6 115,2 216,0 10
53425 24 G 0,75 16,0 172,8 364,0 19 53504 3G6 12,4 172,8 285,0 10
53426 25 G 0,75 16,0 180,0 371,0 19 53505 4G6 13,8 230,4 375,0 10
53427 27 G 0,75 16,0 194,4 387,0 19 53506 5G6 15,4 288,0 465,0 10
53428 30 G 0,75 17,0 216,0 429,0 19 53507 6G6 16,7 345,6 544,0 10
53429 33 G 0,75 18,0 237,6 468,0 19 53508 7G6 18,3 403,2 664,0 10
53430 37 G 0,75 19,0 266,4 550,0 19 52638 1 G 10 7,7 96,0 144,0 8
52633 1G1 3,9 9,6 25,2 18 53509 1 x 10 7,7 96,0 144,0 8
53431 1x1 3,9 9,6 25,2 18 53510 2 x 10 14,7 192,0 351,0 8
53432 2x1 6,3 19,2 50,0 18 53511 3 G 10 15,7 288,0 475,0 8
53433 3G1 6,8 28,8 66,0 18 53512 4 G 10 17,5 384,0 630,0 8
53434 4G1 7,4 38,4 86,0 18 53513 5 G 10 19,6 480,0 782,0 8
53435 5G1 8,3 48,0 106,0 18 53514 6 G 10 21,7 576,0 914,0 8
53436 6G1 8,9 57,6 127,0 18 53515 7 G 10 23,7 672,0 1092,0 8
53437 7G1 9,9 67,2 155,0 18 52639 1 G 16 9,1 153,6 205,0 6
53438 8G1 11,0 76,8 187,0 18 53516 1 x 16 9,1 153,6 205,0 6
53439 10 G 1 12,1 96,0 214,0 18 53517 2 x 16 17,7 307,2 495,0 6
53440 12 G 1 12,1 115,2 230,0 18 53518 3 G 16 19,3 460,8 691,0 6
53441 14 G 1 12,7 134,4 266,0 18 53519 4 G 16 21,5 614,4 905,0 6
53442 16 G 1 13,6 153,6 301,0 18 53520 5 G 16 23,9 768,0 1129,0 6
53443 19 G 1 15,1 182,4 377,0 18 53521 6 G 16 26,2 921,6 1327,0 6
53444 21 G 1 16,0 201,6 419,0 18 53522 7 G 16 28,9 1075,2 1590,0 6
53445 24 G 1 17,1 230,4 464,0 18 52640 1 G 25 10,0 240,0 336,0 4
53446 25 G 1 17,1 240,0 472,0 18 53523 1 x 25 10,9 240,0 336,0 4
53447 27 G 1 17,1 259,2 488,0 18 53524 2 x 25 21,3 480,0 833,0 4
53448 30 G 1 17,7 288,0 536,0 18 53525 3 G 25 22,7 720,0 1139,0 4
53449 33 G 1 18,9 316,8 605,0 18 53526 4 G 25 25,4 960,0 1489,0 4
53450 37 G 1 20,3 355,2 690,0 18 53527 5 G 25 28,1 1200,0 1863,0 4
52634 1 G 1,5 4,3 14,4 32,3 16 53528 6 G 25 31,1 1440,0 2275,0 4
53451 1 x 1,5 4,3 14,4 32,3 16 53529 7 G 25 34,5 1680,0 2633,0 4
53452 2 x 1,5 7,6 28,8 69,0 16 52641 1 G 35 12,1 336,0 454,0 2
53453 3 G 1,5 8,1 43,2 93,0 16 53530 1 x 35 12,1 336,0 454,0 2
53454 4 G 1,5 8,8 57,6 120,0 16 53531 2 x 35 23,7 672,0 1104,0 2
53455 5 G 1,5 9,8 72,0 152,0 16 53532 3 G 35 25,5 1008,0 1513,0 2
53456 6 G 1,5 10,9 86,4 187,0 16 53533 4 G 35 28,4 1344,0 1992,0 2
53457 7 G 1,5 12,0 100,8 222,0 16 53534 5 G 35 31,3 1680,0 2488,0 2
53458 8 G 1,5 14,0 115,2 263,0 16 52642 1 G 50 14,9 480,0 638,0 1
53459 10 G 1,5 14,6 144,0 308,0 16 53535 1 x 50 14,9 480,0 638,0 1
53460 12 G 1,5 14,6 172,8 330,0 16 53536 2 x 50 29,3 960,0 1573,0 1
53461 14 G 1,5 15,4 201,6 383,0 16 53537 3 G 50 31,5 1440,0 2154,0 1
53462 16 G 1,5 16,2 230,4 438,0 16 53538 4 G 50 35,3 1920,0 2819,0 1
53463 19 G 1,5 18,3 273,6 554,0 16 53539 5 G 50 39,1 2400,0 3505,0 1
53464 21 G 1,5 19,7 302,4 614,0 16 52643 1 G 70 17,1 672,0 875,0 2/0
53465 24 G 1,5 21,1 345,6 791,0 16 53540 1 x 70 17,1 672,0 875,0 2/0
53466 25 G 1,5 21,1 360,0 701,0 16 53541 2 x 70 33,7 1344,0 2157,0 2/0
53467 27 G 1,5 21,1 388,8 723,0 16 53542 3 G 70 36,4 2016,0 2946,0 2/0
53543 4 G 70 40,3 2688,0 3888,0 2/0
53544 5 G 70 44,5 3360,0 4864,0 2/0
52644 1 G 95 19,2 912,0 1149,0 3/0
53545 1 x 95 19,2 912,0 1149,0 3/0
53546 2 x 95 37,5 1824,0 2763,0 3/0
53547 3 G 95 40,0 2736,0 3835,0 3/0
53548 4 G 95 45,3 3648,0 5052,0 3/0
53549 5 G 95 50,7 4560,0 6307,0 3/0

Dimensions and specifications may be changed without prior notice. (RE01)

222
Heat resistant Cables

SiHF silicon mulitcore cable, flexible, halogen-free, meter marking

Technical data Cable structure Properties


Special silicone multicore cable with higher
heat-resistance range adapted to
Tinned copper-conductor, to
DIN VDE 0295 cl.5, fine-wire,
Advantages
Hardly changes of dielectric strength E
DIN VDE 0250 part 1 and BS 6360 cl.5, IEC 60228 cl.5 and the insulation resistance also at
DIN VDE 0285-525-2-83/ Core insulation of silicone high temperatures, high ignition or
DIN EN 50525-2-83 Core identification to DIN VDE 0293-308 flash point, in case of fire, forms an
Temperature range - up to 5 cores coloured insulating layer of SiO2
-60C to +180C - from 6 cores, black with continuous Resistant to
(for short time +220C) white numbering High molecular oils, fats from vegetables
Temperature limit at the conductor GN-YE conductor, 3 cores and above and animals, alcohols, plasticizers and
in operation +180C Cores stranded in layers with clophenes, diluted acids, lyes and salt
Nominal voltage U0/U 300/500 V optimal lay-length dissolution, oxidation substances, tropical
Test voltage 2000 V Outer sheath of silicone influences and weather, lake water, oxygen,
Breakdown voltage min. 5000 V Sheath colour preferably redbrown ozone
Insulation resistance with meter marking For laying as a fixed installation only
min. 200 MOhm x km in open or ventilated pipe systems as
Power rating well as in ducts. Otherwise the mechanical
ambient temperature up to +145C properties of the silicon are reduced by
to DIN VDE 0100 the enclosed air at temperatures
for higher temperatures valid: exceeding 90C.
150C - load value 100% Tests
155C - load value 91% Halogen-free
160C - load value 82% acc. to DIN VDE 0482 part 267,
165C - load value 71% DIN EN 50267-2-2/ IEC 60754-2
170C - load value 58% (equivalent DIN VDE 0472 part 813)
175C - load value 41% Behaviour in fire
Minimum bending radius no flame propagation acc. to
flexing 7,5x cable DIN VDE 0482-332-1-2,
fixed installation 4x cable DIN EN 60332-1-2,IEC 60332-1 (equivalent
Radiation resistance DIN VDE 0472 part 804 test method B)
up to 20x106 cJ/kg (up to 20 Mrad)
Note
G = with green-yellow conductor
x = without green-yellow conductor (OB)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
SiHF-C-Si, confer page 232

Application
Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. They are heat-resistant for permanent temperature
up to +180C, for short time operation up to +220C. The good performance of the environmental resistant properties means that silicone cables
can be used at temperatures down to -60C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They
have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to
elastical characteristic of core insulations, these are used as flexible connection cable.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22989 2 x 0,5 5,6 9,6 42,0 20 23002 3 G 0,75 6,8 21,6 63,0 19
22990 3 G 0,5 5,9 14,5 44,0 20 23104 3 x 0,75 6,8 21,6 63,0 19
22940 3 x 0,5 5,9 14,5 44,0 20 23003 4 G 0,75 7,6 29,0 83,0 19
22991 4 G 0,5 6,4 19,3 58,0 20 23105 4 x 0,75 7,6 29,0 83,0 19
22941 4 x 0,5 6,4 19,3 58,0 20 23004 5 G 0,75 8,5 36,0 101,0 19
22992 5 G 0,5 7,3 24,0 62,0 20 22943 5 x 0,75 8,5 36,0 101,0 19
22942 5 x 0,5 7,3 24,0 62,0 20 23005 6 G 0,75 9,2 43,0 115,0 19
22993 6 G 0,5 8,3 28,9 79,0 20 23006 7 G 0,75 9,2 50,0 124,0 19
22994 7 G 0,5 8,1 33,7 85,0 20 23127 8 G 0,75 9,9 57,7 138,0 19
22995 8 G 0,5 8,9 38,4 99,0 20 23128 10 G 0,75 11,1 72,1 156,0 19
22996 10 G 0,5 10,0 48,1 124,0 20 23129 12 G 0,75 12,2 86,5 185,0 19
22997 12 G 0,5 10,6 57,6 141,0 20 23130 16 G 0,75 13,7 115,2 218,0 19
22998 16 G 0,5 12,1 76,7 186,0 20 23131 18 G 0,75 14,6 129,7 260,0 19
22999 18 G 0,5 12,7 86,5 211,0 20 23132 25 G 0,75 17,2 180,0 370,0 19
23000 25 G 0,5 15,2 120,0 271,0 20 23007 2x1 6,6 19,0 59,0 18
23001 2 x 0,75 6,4 14,4 53,0 19 23008 3G1 7,0 29,0 77,0 18

Continuation

223
Heat resistant Cables

SiHF silicon mulitcore cable, flexible, halogen-free, meter marking

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22944 3x1 7,0 29,0 77,0 18 23141 10 G 2,5 15,5 240,1 450,0 14
23009 4G1 7,8 38,0 94,0 18 23033 12 G 2,5 17,1 288,0 502,0 14
22945 4x1 7,8 38,0 94,0 18 23142 16 G 2,5 19,6 384,0 659,0 14
23010 5G1 8,8 48,0 115,0 18 23143 18 G 2,5 20,6 432,2 761,0 14
22946 5x1 8,8 48,0 115,0 18 23144 25 G 2,5 24,4 600,0 1007,0 14
23011 6G1 9,5 58,0 134,0 18 23034 2x4 10,8 77,0 180,0 12
23012 7G1 9,5 67,0 144,0 18 23035 3G4 11,4 115,0 224,0 12
23133 8G1 10,3 76,7 175,0 18 23036 4G4 12,5 154,0 295,0 12
24000 9G1 11,5 86,0 196,0 18 23037 5G4 13,9 192,0 359,0 12
23134 10 G 1 11,5 96,1 216,0 18 23039 7G4 15,6 269,0 479,0 12
23135 12 G 1 12,5 115,2 231,0 18 23040 2x6 12,4 115,0 210,0 10
23136 16 G 1 14,2 153,5 302,0 18 23041 3G6 13,2 173,0 270,0 10
23137 18 G 1 15,1 172,9 340,0 18 23042 4G6 14,8 230,0 341,0 10
23138 25 G 1 18,0 240,0 431,0 18 23043 5G6 16,5 288,0 432,0 10
23013 2 x 1,5 7,6 29,0 81,0 16 23045 7G6 18,0 403,0 552,0 10
23014 3 G 1,5 8,0 43,0 98,0 16 23046 2 x 10 16,2 192,0 400,0 8
22947 3 x 1,5 8,0 43,0 98,0 16 23047 3 G 10 17,2 288,0 507,0 8
23015 4 G 1,5 8,7 58,0 122,0 16 23048 4 G 10 19,4 384,0 644,0 8
22948 4 x 1,5 8,7 58,0 122,0 16 23049 5 G 10 21,4 480,0 788,0 8
23016 5 G 1,5 9,6 72,0 147,0 16 23145 7 G 10 23,4 672,2 1151,0 8
22949 5 x 1,5 9,6 72,0 147,0 16 23050 2 x 16 18,0 308,0 591,0 6
23017 6 G 1,5 10,4 86,0 173,0 16 23051 3 G 16 19,3 462,0 749,0 6
23018 7 G 1,5 10,4 101,0 187,0 16 23052 4 G 16 21,4 616,0 950,0 6
23019 8 G 1,5 11,2 114,0 213,0 16 23053 5 G 16 24,0 770,0 1204,0 6
23020 10 G 1,5 13,0 116,0 263,0 16 23146 7 G 16 26,4 1075,3 1682,0 6
23021 12 G 1,5 13,9 173,0 314,0 16 23054 2 x 25 22,0 480,0 700,0 4
23022 14 G 1,5 14,7 202,0 379,0 16 23055 3 G 25 23,4 720,0 1100,0 4
23023 16 G 1,5 16,2 231,0 445,0 16 23056 4 G 25 26,3 960,0 1500,0 4
23024 18 G 1,5 17,0 260,0 506,0 16 23057 2 x 35 24,6 672,0 1100,0 2
23025 20 G 1,5 17,5 288,0 566,0 16 23058 3 G 35 26,3 1008,0 1500,0 2
23026 24 G 1,5 20,4 346,0 722,0 16 23059 4 G 35 29,1 1344,0 2100,0 2
23027 2 x 2,5 8,8 48,0 134,0 14
23028 3 G 2,5 9,7 72,0 152,0 14
23029 4 G 2,5 10,6 96,0 188,0 14
23030 5 G 2,5 11,6 120,0 228,0 14
23139 6 G 2,5 12,6 144,0 304,0 14
23032 7 G 2,5 12,6 168,0 320,0 14
23140 8 G 2,5 13,6 192,2 373,0 14

Dimensions and specifications may be changed without prior notice. (RE01)

Suitable accessories can be found in Chapter X.


Cable protection tube - HTP

224
Heat resistant Cables

THERMFLEX 180 EWKF silicone multicore cable,


halogen-free, meter marking

Technical data
adapted to DIN VDE 0285-525-2-83/
Cable structure
Tinned copper-conductor, to
Properties
Smoke density - low
E
DIN EN 50525-2-83 DIN VDE 0295 cl.5, fine-wire, Due to the special abrasive and notch
Temperature range BS 6360 cl.5, IEC 60228 cl.5 resistance outer sheath, these cables are
flexing -25C to +180C Core insulation of special silicone suitable for heavy loading of mechanical
fixed installation -60C to +180C compound type EI2 to stresses than the usual standard silicone
Nominal voltage U0/U 300/500 V DIN VDE 0207-363-1 / DIN EN 50363-1 cables
Test voltage 2000 V Core identification to DIN VDE 0293-308 Hardly changes of dielectric strength and
Insulation resistance - up to 5 cores coloured the insulation resistance also at high
min. 200 MOhm x km - from 6 cores, black with continuous temperatures
Minimum bending radius white numbering High ignition or flash point
flexing 7,5x cable GN-YE conductor, 3 cores and above leave in case of fire an insulating layer of
fixed installation 4x cable in the outer layer SiO2, thereby ensuring a longer functional
Radiation resistance Cores stranded in layers with integrity
up to 20x106 cJ/kg (up to 20 Mrad) optimal lay-length Resistant to
Tests Outer sheath of special silicone High molecular oils, fats from vegetables and
Insulation integrity compound type 2GM1 to animals, alcohols, plasticizers and clophenes,
testet acc. to DIN VDE 0472 part 814 DIN VDE 0207-363-2-1/DIN EN 50363-2-1 diluted acids, lyes and salt dissolution,
and IEC 60331 Sheath colour black (RAL 9005) oxidation substances, tropical influences and
Halogen-free with meter marking weather, lake water, oxygen, ozone
acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-1, IEC 60754-1 Note
(equivalent DIN VDE 0472 part 815) G = with green-yellow conductor
Behaviour in fire x = without green-yellow conductor
no flame propagation acc. to AWG sizes are approximate equivalent
DIN VDE 0482-332-1-2, values. The actual cross-section is in mm.
DIN EN 60332-1-2,IEC 60332-1 (equivalent EWKF = Improved values to
DIN VDE 0472 part 804 test method B) E=tearing resistance,
Corrosiveness of combustion gases W=breaking strength propagation,
acc. to DIN VDE 0482 part 267, K=notch strength, F=flexibility
DIN EN 50267-2-2, IEC 60754-2 screened analogue type:
(equivalent DIN VDE 0472 part 813) THERMFLEX 180 EWKF-C, confer page 234

Application
These cables are ideal for use everywhere, where they are exposed to high mechanical stresses, as well as wire insulation are subjected to high
temperatures. For use in dry, damp and wet rooms, as well outdoor. Silicone cables are halogen free and are suitable for use in air conditioning and
heating, for lighting, for the wiring of ovens, saunas and solariums, foundries, steel, cement and ceramic works and in the heating and cooling
equipment.
FRNC = Flame Retardant Non Corrosive
All silicon cables are available also in FRNC versions. The sheath designed with special-compound conform flame test method C to DIN VDE 0472 part
804 and IEC 60332-3 as well as HD 405.3. This special compound is self-extinguishing. Because of that these cables can be installed as security cable
with functionality as for example in communal buildings, power stations, hotels, airports etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
74992 2 x 0,75 6,4 15,0 53,0 19 75008 2 G 2,5 9,8 48,0 135,0 14
74993 3 G 0,75 7,0 22,0 64,0 19 75009 3 G 2,5 10,4 72,0 152,0 14
74994 4 G 0,75 7,6 29,0 84,0 19 75010 4 G 2,5 11,5 96,0 189,0 14
74995 5 G 0,75 8,5 36,0 101,0 19 75011 5 G 2,5 12,9 120,0 229,0 14
74996 2x1 6,8 20,0 60,0 18 75012 2x4 11,6 77,0 180,0 12
74997 3G1 7,2 29,0 78,0 18 75013 3G4 12,3 115,0 230,0 12
74998 4G1 7,8 39,0 95,0 18 75014 4G4 13,6 154,0 300,0 12
74999 5G1 8,8 48,0 116,0 18 75015 5G4 15,2 192,0 380,0 12
75000 2 x 1,5 8,8 29,0 82,0 16 75016 2x6 13,2 115,0 321,0 10
75001 3 G 1,5 8,9 43,0 98,0 16 75017 3G6 14,0 173,0 330,0 10
75002 4 G 1,5 9,9 58,0 122,0 16 75018 4G6 15,5 230,0 430,0 10
75003 5 G 1,5 10,8 72,0 148,0 16 75019 5G6 17,2 288,0 550,0 10
75004 7 G 1,5 12,0 101,0 187,0 16
75005 12 G 1,5 16,1 173,0 315,0 16
75006 16 G 1,5 18,2 231,0 446,0 16
75007 20 G 1,5 19,4 288,0 566,0 16

Dimensions and specifications may be changed without prior notice. (RE01)

225
Heat resistant Cables

H05SS-F / H05SST-F heat-resistant multicore cable

Technical data Cable structure Properties


Heat-resistant multicore cable to Tinned copper-conductor, to Advantages Hardly changes of dielectric
DIN VDE 0285-525-2-83 / DIN VDE 0295 cl.5, fine-wire, strength and the insulation resistance also
DIN EN 50525-2-83 BS 6360 cl.5, IEC 60228 cl.5 at high temperatures
Temperature range Core insulation of cross-linked rubber (SiR) These cables may be damaged by pulling
fixed installation -60C to + 180C compound type EI2 to over sharp-edges or by abrasion during the
(for short time +250C) DIN VDE 0207-363-1 / DIN EN 50363-1 installation and application. To avoid this,
Permissible operating temperature Core identification to DIN VDE 0293-308 it should be treated with great care during
at conductor +180C GN-YE conductor, 3 cores and above the installation and application of the cable.
Nominal voltage U0/U 300/500 V Cores stranded in layers with Tests
Test voltage 2000 V optimal lay-length Behavior in fire:
Specific volume resistivity Outer sheath of cross-linked rubber Test of vertical flame-propagation to
min. 200 MOhm x km compound type EM9 to VDE 0482-332-1-2, DIN EN 60332-1-2,
Minimum bending radius DIN VDE 0207-363-2-1/DIN EN 50363-2-1 not valid for the cables with outer
flexing 7,5x cable Sheath colour black (RAL 9005) polyesterbraiding (Type H05SST-F)
fixed installation 4x cable also available in other colours on request
Radiation resistance H05SST-F Note
up to 20x106 cJ/kg (up to 20 Mrad) Constuction as per H05SS-F G = with green-yellow conductor
Polyester braiding x = without green-yellow conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Multicore cables insulated and sheathed with heat resistant silicone rubber without strain relieving elements are used in high temperatures or with
contact to hot-surfaces. These cables are installed for fixed installation, mechanical protected, for internal wiring of lighting fixtures in industrial
application. It is recommended for the application of the apparatus which are moving during the operation with less mechanical stress.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05SS-F H05SST-F
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
22290 2 x 0,75 5,7 - 7,4 14,4 59,0 19 22343 2 x 0,75 6,7 - 8,4 14,4 63,0 19
22291 3 G 0,75 6,2 - 8,1 21,6 71,0 19 22344 3 G 0,75 7,2 - 9,1 21,6 75,0 19
22292 4 G 0,75 6,8 - 8,8 28,8 93,0 19 22345 4 G 0,75 7,8 - 9,8 28,8 99,0 19
22293 5 G 0,75 7,6 - 9,9 36,0 113,0 19 22346 5 G 0,75 8,6 - 10,9 36,0 120,0 19
22294 2x1 6,1 - 8,0 19,2 67,0 18 22347 2x1 7,1 - 9,0 19,2 71,0 18
22295 3G1 6,5 - 8,5 29,0 86,0 18 22348 3G1 7,5 - 9,5 29,0 91,0 18
22296 4G1 7,1 - 9,3 38,4 105,0 18 22349 4G1 8,1 - 10,3 38,4 111,0 18
22297 5G1 8,0 - 10,3 48,0 129,0 18 22350 5G1 9,0 - 11,3 48,0 137,0 18
22298 2 x 1,5 7,6 - 9,8 29,0 91,0 16 22351 2 x 1,5 8,6 - 10,8 29,0 97,0 16
22299 3 G 1,5 8,0 - 10,4 43,0 110,0 16 22352 3 G 1,5 9,0 - 11,4 43,0 117,0 16
22300 4 G 1,5 9,0 - 11,6 58,0 137,0 16 22353 4 G 1,5 10,0 - 12,6 58,0 145,0 16
22301 5 G 1,5 9,8 - 12,7 72,0 165,0 16 22354 5 G 1,5 10,8 - 13,7 72,0 175,0 16
22302 2 x 2,5 9,0 - 11,6 48,0 150,0 14 22355 2 x 2,5 10,0 - 12,6 48,0 159,0 14
22303 3 G 2,5 9,6 - 12,4 72,0 170,0 14 22356 3 G 2,5 10,6 - 13,4 72,0 180,0 14
22304 4 G 2,5 10,7 - 13,8 96,0 211,0 14 22357 4 G 2,5 11,7 - 14,8 96,0 224,0 14
22305 5 G 2,5 11,9 - 15,3 120,0 255,0 14 22358 5 G 2,5 12,9 - 16,3 120,0 270,0 14
22306 3G4 11,3 - 14,5 115,0 251,0 12 22359 3G4 12,3 - 15,5 115,0 266,0 12
22307 4G4 12,7 - 16,2 154,0 330,0 12 22360 4G4 13,7 - 17,2 154,0 350,0 12
22308 3G6 12,8 - 16,3 173,0 379,0 10 22361 3G6 13,8 - 17,3 173,0 402,0 10
22309 4G6 14,2 - 18,1 230,0 494,0 10 22362 4G6 15,2 - 19,1 230,0 524,0 10

Dimensions and specifications may be changed without prior notice. (RE01)

Suitable accessories can be found in Chapter X.


Cable protection tube - HTP

226
Heat resistant Cables

HELUFLON-FEP-6Y multi core, fluorinated polymeric materials,


-100C up to +205C

Technical data
Fluorinated polymeric insulation FEP
Cable structure
Copper-conductor, bare, tinned, silver
Properties
Higher insulation resistance
E
(Fluorethylenepropylene) to DIN VDE 0295 cl.5, fine-wire, Low dielectric loss
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Not flammable
-100C to +205C Core insulation of FEP-HELUFLON Resistant to micro-cultures
(for short time +230C) Core identification to DIN VDE 0293-308 Do not permit any fungus-formation
Conductor temperature range - up to 0,25 mm cores coloured Absolute ozone resistant
bare copper +130C - from 0,5 mm black cores with Absolute weather resistant
tinned copper +180C continuous white numbering Water absorption <0,01%
silver pl. copper +200C GN-YE conductor, 3 cores and above Minimal water vapour permeability (approx.
Nominal voltage 600 V Cores stranded in layers with 0,18 mgr/cm in 24 hours)
Test voltage 2500 V optimal lay-length The materials used in manufacture are
Insulation resistance Outer sheath of FEP-HELUFLON cadmium-free and contain no silicone
min. 2 GOhm x km Sheath colour black (RAL 9005) and free from substances harmful to
Minimum bending radius the wetting properties of lacquers
flexing 15x cable Tests
fixed installation 4x cable self-extinguishing and flame retardant
Radiation resistance acc. to DIN VDE 0482-332-1-2,
up to 1x106 cJ/kg (up to 1 Mrad) DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This cables are predominantly used for installing in control cabinets subjected to high thermal effects as well as in brickworks, heaters, kitchen fitments
and measuring appliances as well as in the chemical industry. These cables are non-flammable and resistant to acids, alkalis, solvents, oil and petrol.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
copper wire, tinned copper wire, tinned
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24547 2 x 0,25 2,7 5,0 17,0 24 24566 7G1 6,0 67,0 113,0 18
24548 3 G 0,25 2,9 7,5 22,0 24 24273 12 G 1 8,0 115,2 220,0 18
24549 4 G 0,25 3,2 10,0 27,0 24 24274 18 G 1 9,5 173,0 321,0 18
24550 5 G 0,25 3,5 12,5 34,0 24 24275 25 G 1 11,2 240,0 458,0 18
24551 7 G 0,25 3,9 17,5 46,0 24 24501 2 x 1,5 4,9 29,0 45,0 16
24552 2 x 0,5 3,3 9,8 21,0 20 24502 3 G 1,5 5,3 43,0 70,0 16
24553 3 G 0,5 3,5 14,7 32,0 20 24503 4 G 1,5 5,8 58,0 98,0 16
24554 4 G 0,5 3,9 19,6 44,0 20 24504 5 G 1,5 6,5 72,0 117,0 16
24555 5 G 0,5 4,3 24,5 55,0 20 24505 7 G 1,5 7,2 101,0 184,0 16
24556 7 G 0,5 4,8 34,3 70,0 20 24276 12 G 1,5 10,2 173,0 326,0 16
24557 2 x 0,75 3,6 14,4 31,0 19 24277 18 G 1,5 12,3 260,0 504,0 16
24558 3 G 0,75 3,9 21,6 46,0 19 24278 25 G 1,5 14,0 360,0 682,0 16
24559 4 G 0,75 4,3 29,0 58,0 19 24279 3 G 2,5 6,4 72,0 121,0 14
24560 5 G 0,75 4,7 36,0 69,0 19 24280 4 G 2,5 7,0 96,0 182,0 14
24561 7 G 0,75 4,8 50,0 92,0 19 24281 5 G 2,5 7,9 120,0 240,0 14
24562 2x1 4,1 19,0 41,0 18 24282 7 G 2,5 8,7 168,0 316,0 14
24563 3G1 4,4 29,0 55,0 18 24283 3G4 7,5 115,0 212,0 12
24564 4G1 4,9 38,0 71,0 18 24284 4G4 8,3 154,0 304,0 12
24565 5G1 5,5 48,0 88,0 18 24285 5G4 9,2 192,0 386,0 12

Continuation

227
Heat resistant Cables

HELUFLON-FEP-6Y multi core, fluorinated polymeric materials,


-100C up to +205C
Copper wire, bare copper wire, silvered
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. AG Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight weight approx.
mm kg / km kg / km mm kg / km kg / km kg / km
25914 2 x 0,25 2,7 5,0 17,0 24 25952 2 x 0,25 2,7 5,0 0,26 17,0 24
25915 3 G 0,25 2,9 7,5 22,0 24 25953 3 G 0,25 2,9 7,5 0,39 22,0 24
25916 4 G 0,25 3,2 10,0 27,0 24 25954 4 G 0,25 3,2 10,0 0,52 27,0 24
25917 5 G 0,25 3,5 12,5 34,0 24 25955 5 G 0,25 3,5 12,5 0,65 34,0 24
25918 7 G 0,25 3,9 17,5 46,0 24 25956 7 G 0,25 3,9 17,5 0,91 46,0 24
25919 2 x 0,5 3,3 9,8 21,0 20 25957 2 x 0,5 3,3 9,8 0,34 21,0 20
25920 3 G 0,5 3,5 14,7 32,0 20 25958 3 G 0,5 3,5 14,7 0,51 32,0 20
25921 4 G 0,5 3,9 19,6 44,0 20 25959 4 G 0,5 3,9 19,6 0,68 44,0 20
25922 5 G 0,5 4,3 24,5 55,0 20 25960 5 G 0,5 4,3 24,5 0,85 55,0 20
25923 7 G 0,5 4,8 34,3 70,0 20 25961 7 G 0,5 4,8 34,3 1,19 70,0 20
25924 2 x 0,75 3,6 14,4 31,0 19 25962 2 x 0,75 3,6 14,4 0,40 31,0 19
25925 3 G 0,75 3,9 21,6 46,0 19 25963 3 G 0,75 3,9 21,6 0,60 46,0 19
25926 4 G 0,75 4,3 29,0 58,0 19 25964 4 G 0,75 4,3 29,0 0,80 58,0 19
25927 5 G 0,75 4,7 36,0 69,0 19 25965 5 G 0,75 4,7 36,0 1,00 69,0 19
25928 7 G 0,75 5,4 50,0 92,0 19 25966 7 G 0,75 5,4 50,0 1,40 92,0 19
25929 2x1 4,1 19,0 41,0 18 25967 2x1 4,1 19,0 0,52 41,0 18
25930 3G1 4,4 29,0 55,0 18 25968 3G1 4,4 29,0 0,78 55,0 18
25931 4G1 4,9 38,0 71,0 18 25969 4G1 4,9 38,0 1,04 71,0 18
25932 5G1 5,5 48,0 88,0 18 25970 5G1 5,5 48,0 1,30 88,0 18
25933 7G1 6,0 67,0 113,0 18 25971 7G1 6,0 67,0 1,82 113,0 18
25934 12 G 1 8,0 115,2 220,0 18 25972 12 G 1 8,0 115,2 3,12 220,0 18
25935 18 G 1 9,5 173,0 321,0 18 25973 18 G 1 9,5 173,0 4,68 321,0 18
25936 25 G 1 11,2 240,0 458,0 18 25974 25 G 1 11,2 240,0 6,50 458,0 18
25937 2 x 1,5 4,9 29,0 45,0 16 25975 2 x 1,5 4,9 29,0 0,70 45,0 16
25938 3 G 1,5 5,3 43,0 70,0 16 25976 3 G 1,5 5,3 43,0 1,05 70,0 16
25939 4 G 1,5 5,8 58,0 98,0 16 25977 4 G 1,5 5,8 58,0 1,40 98,0 16
25940 5 G 1,5 6,5 72,0 117,0 16 25978 5 G 1,5 6,5 72,0 1,75 117,0 16
25941 7 G 1,5 7,2 101,0 184,0 16 25979 7 G 1,5 7,2 101,0 2,45 184,0 16
25942 12 G 1,5 10,2 173,0 326,0 16 25980 12 G 1,5 10,2 173,0 4,20 326,0 16
25943 18 G 1,5 12,3 260,0 504,0 16 25981 18 G 1,5 12,3 260,0 6,30 504,0 16
25944 25 G 1,5 14,0 360,0 682,0 16 25982 25 G 1,5 14,0 360,0 8,75 682,0 16
25945 3 G 2,5 6,4 72,0 121,0 14 25983 3 G 2,5 6,4 72,0 2,10 121,0 14
25946 4 G 2,5 7,0 96,0 182,0 14 25984 4 G 2,5 7,0 96,0 2,80 182,0 14
25947 5 G 2,5 7,9 120,0 240,0 14 25985 5 G 2,5 7,9 120,0 3,50 240,0 14
25948 7 G 2,5 8,7 168,0 316,0 14 25986 7 G 2,5 8,7 168,0 4,90 316,0 14
25949 3G4 7,5 115,0 212,0 12 25987 3G4 7,5 115,0 3,60 212,0 12
25950 4G4 8,3 154,0 304,0 12 25989 4G4 8,3 154,0 4,80 304,0 12
25951 5G4 9,2 192,0 386,0 12 25990 5G4 9,2 192,0 6,00 386,0 12

Dimensions and specifications may be changed without prior notice. (RE01)

Suitable accessories can be found in Chapter X.


Cable protection tube - HTP

228
Heat resistant Cables

MULTITHERM 400 halogen-free

Technical data Cable structure Properties


Special core insulation
for high temperatures
Copper-conductor nickel plated,
fine-wire (ASTM B 355)
Asbestos and cadmium-free
E
Temperature range 1. Core insulation of braided glass-fibre Note
-60C to +400C impregnated with silicone Further sizes are available on request.
(for short time +500C) 2. Core insulation of braided glass-fibre AWG sizes are approximate equivalent
Nominal voltage 500 V impregnated with silicone values. The actual cross-section is in mm.
Test voltage 2500 V Core identification screened analogue type:
Minimum bending radius - No. of cores with GN-YE conductor MULTITHERM 400-ES, confer page 236
5x cable 3 = GN-YE, BU, BN
4 = GN-YE, BK, BU, BN
5 = GN-YE, BK, BU, BN, WH
6 = GN-YE, BK, BU, BN, WH, RD
7 = GN-YE, BK, BU, BN, WH, RD, GY
- No. of cores without GN-YE conductor
2 = BU, BN
3 = BK, BU, BN
4 = BK, BU, BN, WH
5 = BK, BU, BN, WH, RD
6 = BK, BU, BN, WH, RD, GY
7 = BK, BU, BN, WH, RD, GY, GN
Overall lay up of cores
Outer sheath of braided glass-fibre
impregnated with silicone

Application
MULTITHERM 400 cables are used for applications where extremely high connecting and ambient temperatures can arise, e. g. in iron and steel works,
rolling mills, foundries, glass and ceramic factories, in furnace and power plant construction, during thermoplastic moulding processes etc. The special
construction of the cable is designed for a recommended maximum temperature in damp environmentsof 220C and for dry environments above this
temperature.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Max. permiss. Weight AWG-No. Part no. No.cores x Outer Cop. Max. permiss. Weight AWG-No.
cross-sec. approx. weight current carrying approx. cross-sec. approx. weight current carrying approx.
mm mm kg / km capacity kg / km mm mm kg / km capacity kg / km
at +340C (A) at +340C (A)
51741 2 x 0,5 6,2 10,0 3,3 47,0 20 51761 4 x 1,5 9,1 58,0 8,6 128,0 16
51742 3 x 0,5 6,4 15,0 3,1 50,0 20 51762 5 x 1,5 10,0 72,0 8,3 150,0 16
51743 4 x 0,5 7,5 19,0 3,0 70,0 20 51763 6 x 1,5 10,7 88,0 8,0 175,0 16
51744 5 x 0,5 8,0 25,0 2,9 81,0 20 51764 7 x 1,5 11,0 101,0 7,8 190,0 16
51745 6 x 0,5 8,6 30,0 2,8 97,0 20 51765 2 x 2,5 9,2 48,0 12,2 135,0 14
51746 7 x 0,5 8,7 34,0 2,7 105,0 20 51766 3 x 2,5 9,7 72,0 11,6 153,0 14
51747 2 x 0,75 6,7 14,4 5,1 55,0 19 51767 4 x 2,5 10,6 96,0 11,2 190,0 14
51748 3 x 0,75 7,0 21,6 5,1 66,0 19 50060 5 x 2,5 11,8 120,0 10,8 230,0 14
51749 4 x 0,75 8,0 29,0 4,9 86,0 19 50061 6 x 2,5 12,8 144,0 10,4 270,0 14
51750 5 x 0,75 8,8 36,0 4,7 103,0 19 50062 7 x 2,5 13,0 168,0 10,1 295,0 14
51751 6 x 0,75 9,5 43,0 4,5 119,0 19 50063 2x4 11,0 77,0 16,0 191,0 12
51752 7 x 0,75 9,7 50,0 4,4 130,0 19 50064 3x4 11,4 115,0 15,3 224,0 12
51753 2x1 6,9 19,0 7,0 63,0 18 50065 4x4 13,0 154,0 14,6 285,0 12
51754 3x1 7,8 29,0 6,7 82,0 18 50066 5x4 14,5 192,0 14,1 360,0 12
51755 4x1 8,3 38,0 6,4 98,0 18 50067 7x4 16,5 270,0 13,3 485,0 12
51756 5x1 9,1 48,0 6,2 119,0 18 50068 3x6 14,2 173,0 20,0 340,0 10
51757 6x1 9,8 58,0 6,0 138,0 18 50069 4x6 16,2 230,0 19,0 442,0 10
51758 7x1 10,0 67,0 5,8 150,0 18 50070 5x6 17,7 288,0 18,0 535,0 10
51759 2 x 1,5 8,0 29,0 9,4 87,0 16 50071 4 x 10 20,0 384,0 26,0 710,0 8
51760 3 x 1,5 8,3 43,0 9,0 103,0 16 50072 4 x 16 24,5 615,0 34,0 990,0 6

Dimensions and specifications may be changed without prior notice. (RE01)

Suitable accessories can be found in Chapter X.


Cable protection tube - HTP

229
Heat resistant Cables

HELUTHERM 145 MULTI-C flexible, cross-linked,


halogen-free, Cu-screened, EMC-preferred type

Technical data Cable structure Properties


Temperature-resistant and halogen-free Tinned copper-conductor, to Lower propagation of fire
connection and control cable DIN VDE 0295 cl.5, fine-wire, Low development of smoke and fumes
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Good abrasion and notch resistance
flexing -35C to +120C Core insulation of cross-linked, Good resistance to oils and weathering
fixed installation -55C to +145C halogen-free polyolefin-copolymer Resistant to UV radiation and ozone
in short-circuit +250C Core identification black cores with Resistant to soldering temperatures
Nominal voltage continuous white numbering Thermal class B
up to 1,0 mm U0/U 300/500 V Cores stranded in layers with These control cables are resistant to
from 1,5 mm U0/U 450/750 V optimal lay-lenght melting, even when in contact with a
with protected fixed installation Tinned copper braided screen, soldering iron at temperatures of between
from 1,5 mm U0/U 600/1000 V approx. 85% coverage 300C and 380C, because of the
Test voltage 3000 V Outer sheath of cross-linked, cross-linking for the insulation material
Minimum bending radius halogen-free polyolefin-copolymer The materials used in manufacture are
in operation 8x cable Sheath colour black cadmium-free and contain no silicone
fixed installation 4x cable with meter marking and free from substances harmful to
Coupling resistance Different insulation- and outer sheath in the wetting properties of lacquers
max. 250 Ohm/km other colours available on request Tests
Caloric load values Flame test (unit flame test) acc. to
see Technical Informations Note DIN VDE 0482-332-3-22, BS 4066 Teil 3,
Power ratings table AWG sizes are approximate equivalent DIN EN 60332-3-22, IEC 60332-3-22
see Technical Informations values. The actual cross-section is in mm. (previously DIN VDE 0472
Approval unscreened analogue type: part 804 test method C)
Germanischer Lloyd HELUTHERM 145 MULTI, confer page 221 Flame test (cable) acc. to
DIN VDE 0482-332-1-2, DIN EN 60332-1-2,
IEC 60332-1-2 (equivalent DIN VDE 0472
part 804 test method B)
Corrosiveness of combustion gases
acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-2, IEC 60754-2
(equivalent DIN VDE 0472 part 813)
Halogen-free
acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density
acc. to DIN VDE 0482 part 1034-1+2,
DIN EN 61034-1+2, IEC 61034-1+2,
BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Application
These halogen-free, cross-linked and temperature resistant wiring and control cables with enhanced fire-behaviour properties are used for wiring up
the lighting fixtures, heaters, electric machines (temperature class B), switching systems and distribution switchboards. A very long service life is also
given on account of their excellent high-temperature stability. These cables exhibit good resistance to weathering as well as being very stable to
temperature, moisture, ozone and UV radiation. These cables are therfore mainly used for traffic control systems and diverse outdoor applications.
The development of smoke is low and no corrosive gases are liberated during combustion of these halogen-free cables in case of fire. The risk of toxic
fumes is considerably less in the event of fire because the coloric load values is lower. Precious time can thus be won for a disciplined evacuation, and
unnecessary loss of life can be prevented. The extent of the damage to costly control and monitoring systems and the concrete and steel structures
of buildings and plant due to fire is reduced by this. Injuries to persons and damage to materials can be prevented. A lower conductor cross-section
is possible in certain circumstances because of the high thermal load and thus savings in the space and weight required can be made. These wiring
and control cables provide a significant contribution in safety engineering and environmental protection.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52194 2 x 0,25 5,0 16,0 36,0 24 52196 5 x 0,25 6,4 29,0 68,0 24
52195 3 x 0,25 5,5 21,0 44,0 24 52197 7 x 0,25 7,5 37,0 95,0 24

Continuation

230
Heat resistant Cables

HELUTHERM 145 MULTI-C flexible, cross-linked,


halogen-free, Cu-screened, EMC-preferred type
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52198 1 x 0,5 3,7 15,0 24,0 20 52254 1 x 2,5 5,6 28,0 59,0 14
52199 2 x 0,5 5,6 29,0 55,0 20 52255 2 x 2,5 9,8 96,0 148,0 14
52200 3 x 0,5 6,1 38,0 64,0 20 52256 3 x 2,5 10,4 146,0 183,0 14
52201 4 x 0,5 6,7 45,0 78,0 20 52257 4 x 2,5 11,5 150,0 221,0 14
52202 5 x 0,5 7,3 51,0 95,0 20 52258 5 x 2,5 12,6 200,0 273,0 14
52203 6 x 0,5 7,9 66,0 106,0 20 52259 6 x 2,5 13,8 227,0 326,0 14
52204 7 x 0,5 8,4 68,0 122,0 20 52260 7 x 2,5 15,3 235,0 397,0 14
52205 8 x 0,5 9,0 80,0 138,0 20 52261 8 x 2,5 16,5 265,0 475,0 14
52206 10 x 0,5 10,0 93,0 161,0 20 52262 10 x 2,5 18,3 326,0 542,0 14
52207 12 x 0,5 10,0 107,0 170,0 20 52263 12 x 2,5 18,3 376,0 582,0 14
52208 14 x 0,5 11,0 122,0 193,0 20 52264 14 x 2,5 19,6 428,0 681,0 14
52209 16 x 0,5 11,7 129,0 216,0 20 52265 16 x 2,5 20,7 480,0 778,0 14
52210 19 x 0,5 12,8 158,0 253,0 20 52266 19 x 2,5 23,5 557,0 948,0 14
52211
52212
21 x 0,5
1 x 0,75
13,5
4,0
167,0
18,0
281,0
29,0
20
19
52267
52268
21 x 2,5
1x4
24,4
6,3
606,0
56,0
1042,0
86,0
14
12 E
52213 2 x 0,75 6,6 38,0 71,0 19 52269 2x4 10,9 135,0 196,0 12
52214 3 x 0,75 6,9 50,0 82,0 19 52270 3x4 11,5 178,0 248,0 12
52215 4 x 0,75 7,6 58,0 100,0 19 52271 4x4 12,8 220,0 316,0 12
52216 5 x 0,75 8,3 70,0 117,0 19 52272 5x4 14,3 259,0 376,0 12
52217 6 x 0,75 8,9 85,0 135,0 18 52273 6x4 15,6 302,0 452,0 12
52218 7 x 0,75 9,9 90,0 158,0 19 52274 7x4 17,0 355,0 555,0 12
52219 8 x 0,75 10,6 110,0 178,0 19 52275 8x4 18,3 392,0 655,0 12
52220 10 x 0,75 11,5 140,0 207,0 19 52276 10 x 4 20,7 480,0 767,0 12
52221 12 x 0,75 11,5 148,0 220,0 19 52277 12 x 4 20,7 557,0 829,0 12
52222 14 x 0,75 12,2 167,0 250,0 19 52278 14 x 4 22,1 636,0 948,0 12
52223 16 x 0,75 12,9 183,0 282,0 19 52279 1x6 6,9 81,0 108,0 10
52224 19 x 0,75 14,5 212,0 335,0 19 52280 2x6 12,1 175,0 255,0 10
52225 21 x 0,75 15,3 230,0 370,0 19 52281 3x6 12,8 240,0 330,0 10
52226 1x1 4,2 20,0 33,0 18 52282 4x6 14,3 305,0 429,0 10
52227 2x1 7,0 31,0 78,0 18 52283 5x6 16,0 441,0 536,0 10
52228 3x1 7,4 56,0 92,0 18 52284 6x6 17,4 473,0 624,0 10
52229 4x1 8,1 66,0 112,0 18 52285 7x6 19,3 505,0 751,0 10
52230 5x1 8,9 95,0 134,0 18 52286 1 x 10 8,4 124,0 170,0 8
52231 6x1 9,5 105,0 164,0 18 52287 2 x 10 15,1 265,0 409,0 8
52232 7x1 10,5 109,0 192,0 18 52288 3 x 10 16,4 370,0 550,0 8
52233 8x1 11,4 130,0 219,0 18 52289 4 x 10 18,1 485,0 715,0 8
52234 10 x 1 12,5 138,0 254,0 18 52290 5 x 10 20,2 610,0 882,0 8
52235 12 x 1 12,5 164,0 270,0 18 52291 6 x 10 22,3 715,0 1026,0 8
52236 14 x 1 13,5 198,0 308,0 18 52292 7 x 10 24,3 820,0 1195,0 8
52237 16 x 1 14,3 203,0 350,0 18
52238 19 x 1 16,2 235,0 447,0 18
52239 21 x 1 17,0 257,0 492,0 18
52240 1 x 1,5 4,8 22,0 42,0 16
52241 2 x 1,5 8,2 58,0 105,0 16
52242 3 x 1,5 8,7 71,0 121,0 16
52243 4 x 1,5 9,4 86,0 156,0 16
52244 5 x 1,5 10,5 104,0 188,0 16
52245 6 x 1,5 11,5 118,0 225,0 16
52246 7 x 1,5 12,6 136,0 264,0 16
52247 8 x 1,5 13,7 172,0 308,0 16
52248 10 x 1,5 15,0 193,0 361,0 16
52249 12 x 1,5 15,0 222,0 383,0 16
52250 14 x 1,5 16,0 272,0 458,0 16
52251 16 x 1,5 17,0 285,0 515,0 16
52252 19 x 1,5 19,3 331,0 639,0 16
52253 21 x 1,5 20,3 367,0 705,0 16
51000 25 x 1,5 21,7 526,0 841,0 16

Dimensions and specifications may be changed without prior notice. (RE01)

Suitable accessories can be found in Chapter X.


Cable protection tube - HTP

231
Heat resistant Cables

SiHF-C-Si silicon multicore cable, halogen-free, Cu-screened, EMC-preferred type,


meter marking

Technical data Cable structure Properties


Special silicone-insulated cable with higher Tinned copper-conductor, to Resistant to
heat-resistance adapted to DIN VDE 0295 cl.5, fine-wire, High molecular oils, fats from vegetables
DIN VDE 0250 part 1 and BS 6360 cl.5, IEC 60228 cl.5 and animals, alcohols, plasticizers and
DIN VDE 0285-525-2-83/ Core insulation of silicone clophenes, diluted acids, lyes and salt
DIN EN 50525-2-83 Core identification to DIN VDE 0293-308 dissolution, oxidation substances, tropical
Temperature range - up to 5 cores coloured influences and weather, lake water, oxygen,
-60C to +180C - from 6 cores, black with continuous ozone
(for short time +220C) white numbering For laying as a fixed installation only in open
Temperature limit at the conductor GN-YE conductor, 3 cores and above or ventilated pipe systems as well as in
in operation +180C Cores stranded in layers with ducts. Otherwise the mechanical properties
Nominal voltage U0/U 300/500 V optimal lay-length of the silicon are reduced by the enclosed
Test voltage 2000 V Inner sheath of silicone air at temperatures exceeding 90C.
Breakdown voltage min. 5000 V Tinned copper braided screen, Tests
Insulation resistance approx. 85% coverage Halogen-free
min. 200 MOhm x km Outer sheath of silicone acc. to DIN VDE 0482 part 267,
Power rating Sheath colour preferentially redbrown DIN EN 50267-2-2, IEC 60754-2
at ambient temperatures up to +145C with meter marking (equivalent DIN VDE 0472 part 813)
acc. to DIN VDE 0100 Behaviour in fire
150C - load value 100% no flame propagation acc. to
155C - load value 91% DIN VDE 0482-332-1-2,
160C - load value 82% DIN EN 60332-1-2,IEC 60332-1 (equivalent
165C - load value 71% DIN VDE 0472 part 804 test method B)
170C - load value 58%
175C - load value 41% Note
Minimum bending radius G = with green-yellow conductor
flexing 10x cable x = without green-yellow conductor
fixed installation 5x cable AWG sizes are approximate equivalent
Coupling resistance values. The actual cross-section is in mm.
max. 250 Ohm/km unscreened analogue type:
Radiation resistance SiHF, confer page 223
up to 20x106 cJ/kg (up to 20 Mrad)

Application
Silicone-rubber-insulated cables are used for all applications where the cable insulation is subjected to high temperature fluctuations. These cables
are heat-resistant for continuous use at temperatures up to +180C, as well as for short periods of time at +220C. Silicone-rubber-insulated cables
can also be used at low temperatures down to -60C because of the excellent weathering resistance of the material. These cables are halogen-free
and hence are particularly suitable for applications in iron and steel works, rolling mills, foundries, in aircraft construction and ship building, as well
as in cement, glass and ceramic plants. Silicone-rubber-insulated cables have demonstrated proven applications in projector and high-power lighting
fixtures as well as all types of heating equipment. An interference-free transmission of signals and pulse is assured by the high screening density. The
ideal interference-protected silicone multicore flexible cable for such applications as given above.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
23151 2 x 0,5 8,0 55,5 101,0 20 23160 2 x 0,75 9,0 61,4 124,0 19
23152 3 G 0,5 8,3 60,8 118,0 20 23161 3 G 0,75 9,4 69,1 136,0 19
23153 4 G 0,5 9,1 66,5 131,0 20 23162 4 G 0,75 10,4 86,7 159,0 19
23154 5 G 0,5 9,9 81,6 153,0 20 23163 5 G 0,75 11,3 95,2 180,0 19
23155 7 G 0,5 10,9 92,2 173,0 20 23164 7 G 0,75 12,0 113,3 212,0 19
23156 10 G 0,5 12,8 124,0 242,0 20 23165 10 G 0,75 13,9 165,2 306,0 19
23157 12 G 0,5 13,5 134,4 263,0 20 23166 12 G 0,75 15,2 180,3 333,0 19
23158 16 G 0,5 15,1 170,2 326,0 20 23167 16 G 0,75 16,9 212,2 418,0 19
23159 18 G 0,5 15,9 181,0 351,0 20 23168 18 G 0,75 18,0 282,1 453,0 19
23291 25 G 0,5 18,5 230,1 348,0 20 23292 25 G 0,75 20,8 297,4 468,0 19

Continuation

232
Heat resistant Cables

SiHF-C-Si silicon multicore cable, halogen-free, Cu-screened, EMC-preferred type,


meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
23169 2x1 9,4 66,7 132,0 18 23187 2 x 2,5 12,0 122,3 230,0 14
23170 3G1 9,8 86,2 153,0 18 23188 3 G 2,5 12,9 147,7 275,0 14
23171 4G1 11,1 96,8 173,0 18 23189 4 G 2,5 13,8 188,6 340,0 14
23172 5G1 12,0 108,3 202,0 18 23190 5 G 2,5 14,8 214,9 394,0 14
23173 7G1 12,7 141,2 243,0 18 23191 7 G 2,5 15,8 265,7 488,0 14
23174 10 G 1 14,7 190,0 238,0 18 23192 4G4 16,0 294,0 520,0 12
23175 12 G 1 15,8 209,8 371,0 18 23193 5G4 17,4 374,0 653,0 12
23176 16 G 1 17,4 251,8 468,0 18 23150 2x6 15,8 171,0 350,0 20
23177 18 G 1 18,5 297,4 526,0 18 23194 4G6 18,1 449,0 781,0 10
23293 25 G 1 21,8 329,0 559,0 18 23195 5G6 20,0 563,0 982,0 10
23178 2 x 1,5 10,8 87,7 172,0 16 23196 4 G 10 23,2 759,0 1294,0 8
23179 3 G 1,5 11,2 103,5 198,0 16 23197 4 G 16 25,2 1180,0 1988,0 6
23180 4 G 1,5 12,0 131,7 235,0 16 23198 4 G 25 31,0 1276,0 2995,0 4
23181
23182
5 G 1,5
7 G 1,5
12,8
13,6
148,5
193,4
281,0
345,0
16
16 E
23183 10 G 1,5 14,7 268,5 482,0 16
23184 12 G 1,5 15,8 298,4 531,0 16
23185 16 G 1,5 17,4 362,3 662,0 16
23186 18 G 1,5 20,6 394,0 720,0 16
23294 25 G 1,5 24,2 488,2 791,0 16

Dimensions and specifications may be changed without prior notice. (RE01)

Suitable accessories can be found in Chapter X.


Cable protection tube - HTP

233
Heat resistant Cables

THERMFLEX 180 EWKF-C silicone multicore cable,


halogen-free, screened, EMC-preferred type, meter marking

Technical data Cable structure Properties


adapted to DIN VDE 0285-525-2-83/ Tinned copper-conductor, to Smoke density - low
DIN EN 50525-2-83 DIN VDE 0295 cl.5, fine-wire, Due to the special abrasive and notch
Temperature range BS 6360 cl.5, IEC 60228 cl.5 resistance outer sheath, these cables are
flexing -25C to +180C Core insulation of special silicone suitable for heavy loading of mechanical
fixed installation -60C to +180C compound type EI2 to stresses than the usual standard silicone
Nominal voltage U0/U 300/500 V DIN VDE 0207-363-1 / DIN EN 50363-1 cables
Test voltage 2000 V Core identification to DIN VDE 0293-308 Hardly changes of dielectric strength and
Insulation resistance - up to 5 cores coloured the insulation resistance also at high
min. 200 MOhm x km - from 6 cores, black with continuous temperatures
Minimum bending radius white numbering High ignition or flash point
flexing 10x cable GN-YE conductor, 3 cores and above In case of fire, forms an insulating layer of SiO2
fixed installation 5x cable in the outer layer Resistant to
Coupling resistance Cores stranded in layers with High molecular oils, fats from vegetables
max. 250 Ohm/km optimal lay-length and animals, alcohols, plasticizers and
Radiation resistance Inner sheath of special silicone clophenes, diluted acids, lyes and salt
up to 20x106 cJ/kg (up to 20 Mrad) Tinned copper braided screen, dissolution, oxidation substances, tropical
Tests approx. 85% coverage influences and weather, lake water, oxygen,
Insulation integrity Outer sheath of special silicone ozone
testet acc. to DIN VDE 0472 part 814 compound type 2GM1 to
and IEC 60331 DIN VDE 0207-363-2-1/DIN EN 50363-2-1 Note
Halogen-free Sheath colour black (RAL 9005) G = with green-yellow conductor
acc. to DIN VDE 0482 part 267, with meter marking x = without green-yellow conductor
DIN EN 50267-2-1, IEC 60754-1 AWG sizes are approximate equivalent
(equivalent DIN VDE 0472 part 815) values. The actual cross-section is in mm.
Behaviour in fire EWKF = Improved values to E=tearing
no flame propagation acc. to resistance, W=breaking strength propagation,
DIN VDE 0482-332-1-2, K=notch strength, F=flexibility
DIN EN 60332-1-2,IEC 60332-1 (equivalent unscreened analogue type:
DIN VDE 0472 part 804 test method B) THERMFLEX 180 EWKF, confer page 225
Corrosiveness of combustion gases
acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-2, IEC 60754-2

Application
These cables are ideal for use everywhere, where increased mechanical stresses for the installation and operation are required. Silicone-rubber-insulated
cables are used for all applications where the cable insulation is subjected to high temperature fluctuations. For use in dry, damp and wet rooms as
well outdoor. As flexible connecting cable for low mechanical stress i. e. sauna, solar installations, foundries and steel plants. This cable can be used
for fixed installation only in open and ventilated cable tubes and cable ducts. An interference-free transmission of signals and pulse is assured by the
high screening density.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
FRNC = Flame Retardant Non Corrosive
All silicon cables are available also in FRNC versions. The sheath designed with special-compound conform flame test method C to DIN VDE 0472 part
804 and IEC 60332-3 as well as HD 405.3. This special compound is self-extinguishing. Because of that these cables can be installed as security cable
with functionality as for example in communal buildings, power stations, hotels, airports etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
79804 2 x 0,75 9,0 61,4 124,0 19 79817 16 G 1,5 20,0 362,3 660,0 16
79805 3 G 0,75 9,4 69,1 136,0 19 79818 20 G 1,5 21,3 405,1 766,0 16
79806 4 G 0,75 10,4 86,7 160,0 19 79819 2 x 2,5 12,0 122,3 230,0 14
79807 5 G 0,75 11,2 95,2 180,0 19 79820 3 G 2,5 12,9 147,7 275,0 14
79808 2x1 9,4 66,7 132,0 18 79821 4 G 2,5 13,9 188,6 340,0 14
79809 3G1 9,8 86,2 154,0 18 79822 5 G 2,5 14,8 214,9 395,0 14
79810 4G1 10,7 96,8 176,0 18 79823 2x4 14,2 137,0 308,0 12
79811 5G1 11,6 108,3 207,0 18 79824 3G4 14,9 178,1 364,0 12
79812 2 x 1,5 10,8 87,7 170,0 16 79825 4G4 16,0 294,0 511,0 12
79813 3 G 1,5 11,2 103,5 190,0 16 79826 5G4 17,4 374,0 630,0 12
79814 4 G 1,5 12,0 131,7 231,0 16 79827 2x6 15,8 185,0 418,0 10
79815 5 G 1,5 12,8 148,5 282,0 16 79828 3G6 16,6 241,1 612,0 10
79816 7 G 1,5 13,6 193,4 342,0 16 79829 4G6 18,1 449,0 781,0 10
701219 12 G 1,5 17,2 298,4 531,0 16 79830 5G6 20,0 563,0 980,0 10

Dimensions and specifications may be changed without prior notice. (RE01)

234
Heat resistant Cables

SiHF/GL-P silicon mulitcore cable, steel braiding, halogen-free

Technical data Cable structure Properties


Special silicone multicore cable with higher
heat-resistance range adapted to
Tinned copper-conductor, to
DIN VDE 0295 cl.5, fine-wire,
Advantages
Hardly changes of dielectric strength and E
DIN VDE 0250 part 1 and BS 6360 cl.5, IEC 60228 cl.5 the insulation resistance also at high
DIN VDE 0285-525-2-83/ Core insulation of silicone temperatures, high ignition or flash point,
DIN EN 50525-2-83 Core identification to DIN VDE 0293-308 in case of fire, forms an insulating layer of
Temperature range - up to 5 cores coloured SiO2
-60C to +180C - from 6 cores, black with continuous Resistant to
(for short time +220C) white numbering High molecular oils, fats from vegetables
Temperature limit at the conductor GN-YE conductor, 3 cores and above and animals, alcohols, plasticizers and
in operation +180C Cores stranded in layers with clophenes, diluted acids, lyes and salt
Nominal voltage U0/U 300/500 V optimal lay-length dissolution, oxidation substances, tropical
Test voltage 2000 V Sheath of silicone influences and weather, lake water, oxygen
Breakdown voltage min. 5000 V Glass fibre tape over the sheath For laying as a fixed installation only in open
Insulation resistance Galvanized steel wire outer braiding or ventilated pipe systems as well as in ducts.
min. 200 MOhm x km Otherwise the mechanical properties of the
Power rating silicon are reduced by the enclosed air at
at ambient temperature up to +145C to temperatures exceeding 90C
DIN VDE 0100 for higher temperatures valid: Tests
150C - load value 100% Corrosiveness of combustion gases
155C - load value 91% acc. to DIN VDE 0482 part 267,
160C - load value 82% DIN EN 50267-2-2, IEC 60754-2
165C - load value 71% (equivalent DIN VDE 0472 part 813)
170C - load value 58% Behaviour in fire
175C - load value 41% no flame propagation acc. to
Minimum bending radius DIN VDE 0482-332-1-2,
flexing 10x cable DIN EN 60332-1-2,IEC 60332-1 (equivalent
fixed installation 5x cable DIN VDE 0472 part 804 test method B)
Radiation resistance
up to 20x106 cJ/kg (up to 20 Mrad) Note
G = with green-yellow conductor
x = without green-yellow conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Silicone cables screened with steel braiding were evolved for use wherever insulation is subjected to extreme temperature changes. They are heat-resistant
for permanent temperature up to +180C, for short time operation up to +220C. The good performance of the environmental resistant properties
means that silicone cables can be used at temperatures down to -60C. Silicone cables are halogen-free cables and are especially suited for installation
in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and
cement factories. The screened steel braiding ensures a disturbance-free transmission of signals and impulses.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
23062 2 x 0,75 7,9 14,4 90,0 19 23084 24 G 1,5 21,5 346,0 600,0 16
23063 3 G 0,75 8,3 21,6 101,0 19 23085 2 x 2,5 10,7 48,0 187,0 14
23064 4 G 0,75 9,3 29,0 129,0 19 23086 3 G 2,5 11,2 72,0 205,0 14
23065 5 G 0,75 10,0 36,0 157,0 19 23087 4 G 2,5 12,1 96,0 278,0 14
23067 7 G 0,75 10,7 50,0 177,0 19 23088 5 G 2,5 13,3 120,0 322,0 14
23068 2x1 8,0 19,0 97,0 18 23089 6 G 2,5 14,3 144,0 351,0 14
23069 3G1 8,9 29,0 122,0 18 23090 7 G 2,5 14,4 168,0 380,0 14
23070 4G1 9,4 38,0 141,0 18 23091 2x4 12,5 77,0 240,0 12
23071 5G1 10,4 48,0 166,0 18 23092 3G4 13,0 115,0 311,0 12
23073 7G1 11,1 67,0 197,0 18 23093 4G4 15,0 154,0 384,0 12
23074 2 x 1,5 9,0 29,0 127,0 16 23094 5G4 16,0 192,0 454,0 12
23075 3 G 1,5 9,5 43,0 145,0 16 23095 7G4 17,5 269,0 633,0 12
23076 4 G 1,5 10,3 58,0 173,0 16 23096 2x6 15,1 115,0 321,0 10
23077 5 G 1,5 11,0 72,0 202,0 16 23097 3G6 15,9 173,0 432,0 10
23078 6 G 1,5 12,0 86,0 240,0 16 23098 4G6 18,0 230,0 544,0 10
23079 7 G 1,5 12,0 101,0 244,0 16 23099 5G6 19,4 288,0 656,0 10
23080 8 G 1,5 13,0 115,0 261,0 16 23100 7G6 20,7 403,0 768,0 10
23081 12 G 1,5 15,5 173,0 327,0 16 23101 4 G 10 22,1 384,0 925,0 8
23082 14 G 1,5 16,2 202,0 382,0 16 23102 4 G 16 26,1 614,0 1235,0 6
23083 18 G 1,5 18,7 259,0 440,0 16 23103 4 G 25 30,4 960,0 1700,0 4

Dimensions and specifications may be changed without prior notice. (RE01)

235
Heat resistant Cables

MULTITHERM 400-ES halogen-free, high-grade steel braiding

Technical data Cable structure Properties


Special core insulation Copper-conductor nickel plated, Asbestos and cadmium-free
for high temperatures fine-wire (ASTM B 355)
Temperature range 1. Core insulation of braided glass-fibre Note
-60C to +400C impregnated with silicone Further sizes are available on request.
(for short time +500C) 2. Core insulation of braided glass-fibre AWG sizes are approximate equivalent
Nominal voltage 500 V impregnated with silicone values. The actual cross-section is in mm.
Test voltage 2500 V Core identification unscreened analogue type:
Minimum bending radius - No. of cores with GN-YE conductor MULTITHERM 400, confer page 229
5x cable 3 = GN-YE, BU, BN
4 = GN-YE, BK, BU, BN
5 = GN-YE, BK, BU, BN, WH
6 = GN-YE, BK, BU, BN, WH, RD
7 = GN-YE, BK, BU, BN, WH, RD, GY
- No. of cores without GN-YE conductor
2 = BU, BN
3 = BK, BU, BN
4 = BK, BU, BN, WH
5 = BK, BU, BN, WH, RD
6 = BK, BU, BN, WH, RD, GY
7 = BK, BU, BN, WH, RD, GY, GN
Overall lay up of cores
Outer sheath of braided glass-fibre
impregnated with silicone
braided high-grade steel,
coverage approx. 80%

Application
Where extremely high connecting and ambient temperatures occur, e. g. in iron and steel works, rolling mills, foundries, glass and ceramic plants, in
power plant construction, in the chemical industry, nuclear technology, crude oil engineering, in technical applications in medicine, as well as for
wiring resistances in electrical heating equipment, furnaces and machinery in thermoplastic forming. Due to the special construction of the cable, a
maximum temperature of approx. 220C is recommended for use in damp environments. Applications at temperatures above this should be used in
dry environments only. The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The braided
screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Max. permiss. Weight AWG-No. Part no. No.cores x Outer Cop. Max. permiss. Weight AWG-No.
cross-sec. approx. weight current carrying approx. cross-sec. approx. weight current carrying approx.
mm mm kg / km capacity kg / km mm mm kg / km capacity kg / km
at +340C (A) at +340C (A)
52018 2 x 0,5 7,1 10,0 3,3 84,0 20 52038 4 x 1,5 10,0 58,0 8,6 183,0 16
52019 3 x 0,5 7,3 15,0 3,1 89,0 20 52039 5 x 1,5 10,9 72,0 8,3 212,0 16
52020 4 x 0,5 8,4 19,0 3,0 111,0 20 52040 6 x 1,5 11,6 88,0 8,0 241,0 16
52021 5 x 0,5 8,9 25,0 2,9 126,0 20 52041 7 x 1,5 11,9 101,0 7,8 259,0 16
52022 6 x 0,5 9,5 30,0 2,8 146,0 20 52042 2 x 2,5 10,1 48,0 12,2 191,0 14
52023 7 x 0,5 9,6 34,0 2,7 158,0 20 52043 3 x 2,5 10,6 72,0 11,6 213,0 14
52024 2 x 0,75 7,6 14,4 5,1 95,0 19 52044 4 x 2,5 11,5 96,0 11,2 256,0 14
52025 3 x 0,75 7,9 21,6 5,1 109,0 19 52045 5 x 2,5 12,7 120,0 10,8 307,0 14
52026 4 x 0,75 8,9 29,0 4,9 131,0 19 52046 6 x 2,5 14,9 144,0 10,4 359,0 14
52027 5 x 0,75 9,7 36,0 4,7 157,0 19 52047 7 x 2,5 15,1 168,0 10,1 388,0 14
52028 6 x 0,75 10,4 43,0 4,5 177,0 19 52048 2x4 11,9 77,0 16,0 260,0 12
52029 7 x 0,75 10,6 50,0 4,4 190,0 19 52049 3x4 12,3 115,0 15,3 303,0 12
52030 2x1 7,8 19,0 7,0 105,0 18 52050 4x4 15,1 154,0 14,6 378,0 12
52031 3x1 8,7 29,0 6,7 126,0 18 52051 5x4 15,6 192,0 14,1 458,0 12
52032 4x1 9,2 38,0 6,4 148,0 18 52052 7x4 16,6 270,0 13,3 593,0 12
52033 5x1 10,0 48,0 6,2 174,0 18 52053 3x6 16,3 173,0 20,0 442,0 10
52034 6x1 10,7 58,0 6,0 198,0 18 52054 4x6 18,3 230,0 19,0 567,0 10
52035 7x1 10,9 67,0 5,8 212,0 18 52055 5x6 19,8 288,0 18,0 671,0 10
52036 2 x 1,5 8,9 29,0 9,4 132,0 16 52056 4 x 10 22,1 384,0 26,0 866,0 8
52037 3 x 1,5 9,2 43,0 9,0 153,0 16 52057 4 x 16 26,6 615,0 34,0 1203,0 6

Dimensions and specifications may be changed without prior notice. (RE01)

236
237
ALLWEATHER & RUBBER CABLES

3
in

E
VD eld 29
ng

x
xe
ex

VD
ed
U

R/ shi E 0
xi
- fi
- fl

./
0 /

le

ed
i

no
H A ed / VD
-f

-f
U
C)

C)

ge

us

us

CS REG
e n es /
(

e
lta

di

di

se
re

re

t
fre

ut tan

r
n
ra

ra

co
tu

tu

u
vo

E
ai
n-

or
sis
ra

ra

A
d
ch
al

ge
in

in
pe

pe

re
do
re
in

ge
nd

nd

ag
lo

lo

re
V-
m

L/
om

Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
N
Allweather & rubber cables

YELLOWFLEX -25 to +60 -30 to +60 450/750 7.5x 4x X X 240

H05RR-F / H05RN-F -30 to +60 300/500 7.5x 7.5x (X) X X 241

H07RN-F -30 to +60 450/750 7.5x 4x X X X 242

A07RN-F -30 to +60 450/750 7.5x 4x X X X 244 F


NEOPRENE control cable -25 to +60 -40 to +80 300/500 12.5x 12.5x X X 245

NSSHU -25 to +80 -40 to +80 0.6/1 kV 10x 4x X X X 246

LIFT-TRAGO -30 / -60



-5 to +50 -40 to +70 300/500 20x 20x 247

TRAGO / Lift-2S -15 to +70 -40 to +70 300/500 20x 20x X X X 248

BAULIFTKABEL B101 / B102 / B103 -10 to +80 -10 to +80 300/500 10x 10x X X 249

HELUSPREADER YSLT-J -20 to +60 -20 to +60 300/500 15x 15x X X 250

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

239
Allweather, Rubber and Liftcables

YELLOWFLEX cold flexible, robust, meter marking

Technical data Cable structure Properties


Rubber sheathed cable adapted to Bare copper-conductor, to Increased stability
DIN VDE 0285-525-2-21 / DIN VDE 0295 cl.5, fine-wire, Tear-resistant
DIN EN 50525-2-21 BS 6360 cl.5, IEC 60228 cl.5 Resistant to
Temperature range Core insulation of rubber, EI4 to Atmospheric influences
flexing -25C to +60C DIN VDE 0207-363-1 / DIN EN 50363-1 Largely resistant to
fixed installation -30C to +60C Core identification to DIN VDE 0293-308 Oils and fats
Permissible operating temperature - up to 5 cores coloured Tests
at conductor +60C - from 6 cores, black with continuous Behaviour in fire
Nominal voltage U0/U 450/750 V white numbering to DIN VDE 0482-332-1-2
with protected fixed installation GN-YE conductor, 3 cores and above DIN EN 60332-2-1, IEC 60332-1 (equivalent
U0/U 600/1000 V Cores stranded in layers with DIN VDE 0472 part 804 test method B)
Highest permissible operating voltage optimal lay-length
in three-phase and one-phase Outer sheath of special EM2 to Note
a.c. systems U0/U 476/825 V DIN VDE 0207-363-2-1/DIN EN 50363-2-1 G = with green-yellow conductor
in d.c. systems U0/U 619/1238 V Sheath colour yellow (RAL 1021) x = without green-yellow conductor.
Test voltage 2500 V with meter marking AWG sizes are approximate equivalent
Minimum bending radius Individual printing: values. The actual cross-section is in mm.
for fixed installation 4x cable Article numbers for individual printing: individual marking
for guiding over roller 7,5x cable Part no. 37359 for 3G1,5 mm
during winding on drums 5x cable Part no. 37360 for 3G2,5 mm
Part no. 37361 for 5G1,5 mm
Part no. 37362 for 5G2,5 mm
Usual length:
500m or 1000m drum
Minimum quantity
500m drum
price for 500m drum 102,25 Euro
price for 1000m drum 153,40 Euro

Application
These robust rubber sheathed cables can be used where high demands are placed flexibility and mechanical stress. For application in dry, moist and
wet rooms and in open air, in steel works and rolling mills in heating and air-conditioning systems, in the bottling industry, in machinery and plant
construction, in the chemical industry as well as for the professional and the hobby enthusiast. The choice of yellow as the sheath colour ensures
additional safety. Can be used in potentially explosive areas acc. to DIN VDE 0165.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
37259 2x1 7,7 - 10,0 19,0 98,0 18 37273 2x4 11,8 - 15,1 77,0 282,0 12
37260 3G1 8,3 - 10,7 29,0 131,0 18 37274 3G4 12,7 - 16,2 115,0 322,0 12
37261 4G1 9,2 - 11,9 38,0 150,0 18 37275 4G4 14,0 - 17,9 154,0 397,0 12
37262 5G1 10,2 - 13,1 48,0 220,0 18 37276 5G4 15,6 - 19,9 192,0 486,0 12
37263 2 x 1,5 8,5 - 11,0 29,0 135,0 16 37277 4G6 15,7 - 20,0 230,0 541,0 10
37264 3 G 1,5 9,2 - 11,9 43,0 165,0 16 37278 5G6 17,5 - 22,2 288,0 652,0 10
37265 4 G 1,5 10,2 - 13,1 58,0 200,0 16 37279 4 G 10 20,9 - 26,5 384,0 952,0 8
37266 5 G 1,5 11,2 - 14,4 72,0 241,0 16 37280 5 G 10 22,9 - 29,1 480,0 1203,0 8
37267 7 G 1,5 16,5 - 16,5 101,0 375,0 16 37281 4 G 16 23,8 - 30,1 614,0 1260,0 6
37268 12 G 1,5 17,6 - 22,4 175,0 460,0 16 37282 5 G 16 26,4 - 33,3 768,0 1550,0 6
37269 2 x 2,5 10,2 - 13,1 48,0 194,0 14 37283 4 G 25 28,9 - 36,6 960,0 1860,0 4
37270 3 G 2,5 10,9 - 14,0 72,0 235,0 14 37284 5 G 25 32,0 - 40,4 1200,0 2250,0 4
37271 4 G 2,5 12,1 - 15,5 96,0 290,0 14 37285 4 G 35 32,5 - 41,1 1344,0 2374,0 2
37272 5 G 2,5 13,3 - 17,0 120,0 347,0 14 37286 5 G 35 40,6 - 40,6 1680,0 2752,0 2

Dimensions and specifications may be changed without prior notice. (RF01)

Suitable accessories can be found in Chapter X.


Cable tie - T-WS

Also available as pre-assembled cable - see page 902.

240
Allweather, Rubber and Liftcables

H05RR-F / H05RN-F rubber-sheathed cable

Technical data Cable structure Properties


to DIN VDE 0285-525-2-21 / Bare copper-conductor, to Oils and fats are allowed to come in touch
DIN EN 50525-2-21, IEC 60245-4 DIN VDE 0295 cl.5, fine-wire, Tests
H05RR-F additionally to BS 6500 BS 6360 cl.5, IEC 60228 cl.5 Behaviour in fire
Temperature range Core insulation of rubber EI4 to to DIN VDE 0482-332-1-2
-30C to +60C DIN VDE 0207-363-1 / DIN EN 50363-1 DIN EN 60332-2-1, IEC 60332-1 (equivalent F
Permissible operating temperature Core identification to DIN VDE 0293-308 DIN VDE 0472 part 804 test method B)
at conductor +60C Cores laid up
Nominal voltage U0/U 300/500 V Outer sheath black: Note
Max. operating voltage RR-F = Rubber, EM3 to G = with green-yellow conductor
three-phase and one-phase a.c. DIN VDE 0207-363-2-1/DIN EN 50363-2-1 x = without green-yellow conductor
U0/U 318/550 V RN-F = EM2 to AWG sizes are approximate equivalent
for direct current DIN VDE 0207-363-2-1/DIN EN 50363-2-1 values. The actual cross-section is in mm.
U0/U 413/825 V H05RR-F is replaced the former
Test voltage 2000 V type NLH and NMH up to 2,5 mm.
Minimum bending radius H05RN-F is replaced to former
7,5x cable type NMHU up to 1 mm.
at 1,5 mm - not in VDE;
adapted to VDE (H)05 RN-F
Art.no. 36008 = national type: A05 RN-F
Art-no. 36007 = (A)05 RN-F, outer sheath
colour grey, for window shades manufacturer
Further sizes are available on request.

Application
H05RR-F
These cables are suitable for connecting electrical appliances, for example vacuum cleaner, flat irons, soldering irons, kitchen appliances, toaster,
stoves etc. They were also used for medium mechanical stress in households and offices. These cables are suitable for fixed installation in partition
walls, furniture, decoration covering and in hollow spaces of prefabricated building parts. They are not suitable for use in open air, in industries (also
permitted to tailor workshops and of that kind) or in agriculture plants and for connecting commercial electrical tools.
H05RN-F
These cables are suitable for connecting electrical equipment with low mechanical stress in dry, damp and wet places as well in open air, for example
as connection cable for horticulture tools. These cables can be used in contact with fats and oils (for example deep fryer). They are also suitable for
fixed installation, for example in furniture, decoration covering, partition walls and in hollow spaces of prefabricated building parts. The installation
in hazardous areas is allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05RR-F H05RN-F
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
35001 2 x 0,75 5,7 - 7,4 14,4 60,0 19 36001 2 x 0,75 5,7 - 7,4 14,4 78,0 19
35005 3 G 0,75 6,2 - 8,1 21,6 74,0 19 36003 3 G 0,75 6,2 - 8,1 21,6 94,0 19
35009 4 G 0,75 6,8 - 8,8 29,0 78,0 19 36007 4 G 0,75 6,8 - 8,8 29,0 90,0 19
35019 5 G 0,75 7,6 - 9,9 36,0 99,0 19 36008 4 G 0,75 6,8 - 8,8 29,0 90,0 19
35002 2x1 6,1 - 8,0 19,0 72,0 18 36002 2x1 6,1 - 8,0 19,0 94,0 18
35006 3G1 6,5 - 8,5 29,0 85,0 18 36004 3G1 6,5 - 8,5 29,0 114,0 18
35010 4G1 7,1 - 9,3 38,0 98,0 18 36005 3 G 1,5 8,6 - 11,0 43,0 157,0 16
35020 5G1 8,0 - 10,3 48,0 134,0 18 36006 5 G 1,5 10,5 - 13,5 72,0 228,0 16
35003 2 x 1,5 7,6 - 9,8 29,0 98,0 16
35007 3 G 1,5 8,0 - 10,4 43,0 120,0 16
35011 4 G 1,5 9,0 - 11,6 58,0 150,0 16
35013 5 G 1,5 9,8 - 12,7 72,0 180,0 16
35004 2 x 2,5 9,0 - 11,6 48,0 145,0 14
35008 3 G 2,5 9,6 - 12,4 72,0 170,0 14
35012 4 G 2,5 10,7 - 13,8 96,0 220,0 14
35014 5 G 2,5 11,9 - 15,3 120,0 270,0 14
35015 3G4 11,3 - 14,5 115,0 260,0 12
35017 4G4 12,7 - 16,2 154,0 340,0 12
35016 3G6 12,8 - 16,3 173,0 361,0 10
35018 4G6 14,2 - 18,1 230,0 462,0 10

Dimensions and specifications may be changed without prior notice. (RF01)

241
Allweather, Rubber and Liftcables

H07RN-F rubber-sheathed cable, harmonized type

Technical data Cable structure Properties


Rubber sheathed cable H07RN-F to Bare copper-conductor, to Resistant to
DIN VDE 0285-525-2-21, BS 7919 DIN VDE 0295 cl.5, fine-wire, Weather
DIN EN 50525-2-21, IEC 60245-4 BS 6360 cl.5, IEC 60228 cl.5 Tests
Temperature range Core insulation of rubber EI4 to Behaviour in fire
-30C to +60C DIN VDE 0207-363-1 / DIN EN 50363-1 to DIN VDE 0482-332-1-2
Permissible operating temperature Core identification to DIN VDE 0293-308 DIN EN 60332-2-1, IEC 60332-1 (equivalent
at conductor +60C - up to 5 cores coloured DIN VDE 0472 part 804 test method B)
Nominal voltage - from 6 cores, black with continuous Ozone resistant of the insulation to
U0/U 450/750 V white numbering DIN VDE 0472 part 805, test method A or
in case of protected and fixed installation GN-YE conductor, 3 cores and above part 805 A1, test method C
U0/U 600/1000 V Cores stranded in layers with Oil resistant test according to
Max. permissible operating voltage in optimal lay-length DIN VDE 0473-811-404,DIN EN 60811-404
three phase and one phase a.c. system Outer sheath of rubber EM2 to
U0/U 476/825 V DIN VDE 0207-363-2-1/DIN EN 50363-2-1 Note
direct current-system Sheath colour black G = with green-yellow conductor
U0/U 619/1238 V x = without green-yellow conductor
Test voltage 2500 V AWG sizes are approximate equivalent
Permanent tensile load values. The actual cross-section is in mm.
max. 15 N/mm The core identification of a single core
Minimum bending radius sheathed, of an insulated wire is black.
for fixed installation 4x cable
for guiding over roller 7,5x cable
during winding on drums 5x cable

Application
Heavy duty rubber-sheathed flexible cables are suited for use for medium mechanical stress in dry, damp and wet areas as well as in open air and in
agriculture plants. They are used for equipment in industry works such as boilers, heating plates, hand lamps, electric tools such as drills, circular saws
and homework tools as well as for transportable motors or machines at site. These cables are also suitable for fixed installation on plaster, in temporary
buildings and residential barracks. They are suitable for direct laying on components and mechanical parts of machines, for example lifts and cranes.
They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage
up to 1000 V alternating voltage or a direct voltage up to 750 V against ground. The operating direct voltage is permitted up to 900 V against ground
when they are used in rail-coaches. Installation in hazardous areas according to DIN VDE 0165 is allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
37001 1 x 1,5 5,7 - 7,1 14,4 58,0 16 37021 2 x 2,5 10,2 - 13,1 48,0 193,0 14
37002 1 x 2,5 6,3 - 7,9 24,0 71,0 14 37022 2x4 11,8 - 15,1 77,0 280,0 12
37003 1x4 7,2 - 9,0 38,0 100,0 12 37023 2x6 13,1 - 16,8 115,0 330,0 10
37004 1x6 7,9 - 9,8 58,0 130,0 10 37024 2 x 10 17,7 - 22,6 192,0 586,0 8
37005 1 x 10 9,5 - 11,9 96,0 230,0 8 37025 2 x 16 20,2 - 25,7 307,0 810,0 6
37006 1 x 16 10,8 - 13,4 154,0 290,0 6 37026 2 x 25 24,3 - 30,7 480,0 1160,0 4
37007 1 x 25 12,7 - 15,8 240,0 420,0 4 37027 3G1 8,3 - 10,7 29,0 130,0 18
37008 1 x 35 14,3 - 17,9 336,0 530,0 2 37028 3 G 1,5 9,2 - 11,9 43,0 165,0 16
37009 1 x 50 16,5 - 20,6 480,0 750,0 1
37010 1 x 70 18,6 - 23,3 672,0 960,0 2/0
37011 1 x 95 20,8 - 26,0 912,0 1250,0 3/0
37012 1 x 120 22,8 - 28,6 1152,0 1560,0 4/0
37013 1 x 150 25,2 - 31,4 1440,0 1900,0 300 kcmil
37014 1 x 185 27,6 - 34,4 1776,0 2300,0 350 kcmil
37015 1 x 240 30,6 - 38,3 2304,0 2950,0 500 kcmil
37016 1 x 300 33,5 - 41,9 2880,0 3600,0 600 kcmil
37017 1 x 400 37,4 - 46,8 3840,0 4600,0 750 kcmil
37018 1 x 500 41,3 - 52,0 4800,0 6000,0 1000 kcmil
37019 2x1 7,7 - 10,0 19,0 98,0 18
37020 2 x 1,5 8,5 - 11,0 29,0 135,0 16

Continuation

242
Allweather, Rubber and Liftcables

H07RN-F rubber-sheathed cable, harmonized type

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
37029 3 G 2,5 10,9 - 14,0 72,0 235,0 14 37056 4 G 120 53,0 - 66,0 4608,0 6830,0 4/0
37030 3G4 12,7 - 16,2 115,0 320,0 12 37057 4 G 150 58,0 - 73,0 5760,0 8320,0 300 kcmil
37031 3G6 14,1 - 18,0 173,0 420,0 10 37058 4 G 185 64,0 - 80,0 7104,0 9800,0 350 kcmil
37032 3 G 10 19,1 - 24,2 288,0 810,0 8 37059 4 G 240 72,0 - 91,0 9216,0 12100,0 500 kcmil
37033 3 G 16 21,8 - 27,6 461,0 1050,0 6 37060 4 G 300 80,0 - 101,0 11520,0 15200,0 600 kcmil
37034 3 G 25 26,1 - 33,0 720,0 1250,0 4 37061 5 G 1,5 11,2 - 14,4 72,0 240,0 16
37035 3 G 35 29,3 - 37,1 1008,0 1900,0 2 37062 5 G 2,5 13,3 - 17,0 120,0 345,0 14
37036 3 G 50 34,1 - 42,9 1440,0 2600,0 1 37063 5G4 15,6 - 19,9 192,0 485,0 12
37037 3 G 70 38,4 - 48,3 2016,0 3400,0 2/0 37064 5G6 17,5 - 22,2 288,0 650,0 10
37038 3 G 95 43,3 - 54,0 2736,0 4450,0 3/0 37065 5 G 10 22,9 - 29,1 480,0 1200,0 8
37039 3 G 120 47,4 - 60,0 3456,0 5180,0 4/0 37066 5 G 16 26,4 - 33,3 768,0 1550,0 6
37040 3 G 150 52,0 - 66,0 4320,0 6500,0 300 kcmil 37067 5 G 25 32,0 - 40,4 1200,0 2250,0 4
37041 3 G 185 57,0 - 72,0 5328,0 7860,0 350 kcmil 37068 5 G 35 35,7 - 45,1 1680,0 2750,0 2
37042 3 G 240 65,0 - 82,0 6912,0 10224,0 500 kcmil 37091 5 G 50 41,8 - 53,0 2400,0 3950,0 1
37043 3 G 300 72,0 - 90,0 8640,0 12620,0 600 kcmil 37154 5 G 70 47,5 - 60,0 3360,0 4740,0 2/0
37044 4G1 9,2 - 11,9 38,0 150,0 18 34090 5 G 95 54,0 - 67,0 4560,0 6600,0 3/0
37045 4 G 1,5 10,2 - 13,1 58,0 200,0 16 34349 5 G 120 58,0 - 73,0 5760,0 8180,0 4/0
37046 4 G 2,5 12,1 - 15,5 96,0 290,0 14 34127 5 G 150 64,0 - 80,0 7200,0 10600,0 300 kcmil
37047 4G4 14,0 - 17,9 154,0 395,0 12 37092 7 G 1,5 14,7 - 18,7 101,0 375,0 16
37048
37049
4G6
4 G 10
15,7 - 20,0
20,9 - 26,5
230,0
384,0
540,0
950,0
10
8
37079
37093
7 G 2,5
12 G 1,5
17,1 - 21,8
17,6 - 22,4
168,0
175,0
520,0
460,0
14
16 F
37050 4 G 16 23,8 - 30,1 614,0 1260,0 6 37096 12 G 2,5 20,6 - 26,2 288,0 760,0 14
37051 4 G 25 28,9 - 36,6 960,0 1860,0 4 37097 18 G 2,5 24,4 - 30,9 432,0 850,0 14
37052 4 G 35 32,5 - 41,1 1344,0 2380,0 2 37094 19 G 1,5 20,7 - 26,3 274,0 810,0 16
37053 4 G 50 37,7 - 47,5 1920,0 3190,0 1 37098 19 G 2,5 25,5 - 31,0 456,0 1075,0 14
37054 4 G 70 42,7 - 54,0 2688,0 4260,0 2/0 37095 24 G 1,5 24,3 - 30,7 346,0 1015,0 16
37055 4 G 95 48,4 - 61,0 3648,0 5600,0 3/0 37099 24 G 2,5 28,8 - 36,4 576,0 1390,0 14

Dimensions and specifications may be changed without prior notice. (RF01)

Suitable accessories can be found in Chapter X.


Cable tie - T-WS

243
Allweather, Rubber and Liftcables

A07RN-F rubber-sheathed cable, authorised national type

Technical data Cable structure Properties


Rubber sheathed cable A07RN-F to Bare copper-conductor, to Resistant to
DIN VDE 0285-525-2-21 / DIN VDE 0295 cl.5, fine-wire, Weather
DIN EN 50525-2-21 BS 6360 cl.5, IEC 60228 cl.5 Test
Temperature range Core insualtion of rubber EI4 to Behaviour in fire
-30C to +60C DIN VDE 0207-363-1 / DIN EN 50363-1 to DIN VDE 0482-332-1-2
Permissible operating temperature Core identification to DIN VDE 0293-308 DIN EN 60332-2-1, IEC 60332-1 (equivalent
at conductor +60C - up to 5 cores coloured DIN VDE 0472 part 804 test method B)
Nominal voltage U0/U 450/750 V - from 6 cores, black with continuous Ozone resistant of the insulation to
in case of protected and fixed installation white numbering DIN VDE 0472 part 805, test method A or
U0/U 600/1000 V Cores stranded in layers in part 805 A1, test method C
max. permissible operating voltage in optimal lay-length
three phase and one phase a.c. system Outer sheath of rubber EM2 to Note
U0/U 476/825 V DIN VDE 0207-363-2-1/DIN EN 50363-2-1 G = with green-yellow conductor
direct current-system Sheath colour black x = without green-yellow conductor
U0/U 619/1238 V AWG sizes are approximate equivalent
Test voltage 2500 V values. The actual cross-section is in mm.
Permanent tensile load A07RN-F = Authorized national
max. 15 N/mm rubber-sheathed cable
under consideration of Valid for design with central core + 7 cores.
total copper cross-sections The core identification of a single core
Minimum bending radius sheathed, of an insulated wire is black.
for fixed installation 4x cable
for guiding over roller 7,5x cable
during winding on drums 5x cable

Application
Heavy duty rubber-sheathed flexible cables are suited for use for medium mechanical stress in dry, damp and wet areas as well as in open air and in
agriculture plants. They are used for equipment in industry works such as boilers, heating plates, hand lamps, electric tools such as drills, circular saws
and homework tools as well as for transportable motors or machines at site. These cables are also suitable for fixed installation on plaster, in temporary
buildings and residential barracks. They are suitable for direct laying on components and mechanical parts of machines, for example lifts and cranes.
They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage
up to 1000 V alternating voltage or a direct voltage up to 750 V against ground. The operating direct voltage is permitted up to 900 V against ground
when they are used in rail-coaches. Installation in hazardous areas according to DIN VDE 0165 is allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
A07 RN-F (with green-yellow protective conductor) A07 RN-F (without green-yellow protective conductor)
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
37069 7 G 1,5 14,7 - 18,7 101,0 370,0 16 37080 3 x 1,5 9,2 - 11,9 43,0 165,0 16
37070 7 G 2,5 17,1 - 21,8 168,0 500,0 14 37081 3 x 2,5 10,9 - 14,0 72,0 235,0 14
37071 12 G 1,5 17,6 - 22,4 173,0 520,0 16 37082 3x4 12,7 - 16,2 115,0 320,0 12
37072 12 G 2,5 20,6 - 26,2 288,0 720,0 14 37083 3x6 14,1 - 18,0 173,0 495,0 10
37078 19 G 1,5 20,7 - 26,3 274,0 800,0 16 37084 3 x 10 19,1 - 24,2 288,0 880,0 8
37073 19 G 2,5 25,5 - 31,0 456,0 1100,0 14 37085 3 x 16 21,8 - 27,6 461,0 1095,0 6
37074 24 G 2,5 28,8 - 36,4 576,0 1350,0 14 37086 3 x 25 26,1 - 33,0 720,0 1450,0 4
37075 27 G 1,5 25,5 - 31,5 385,0 1100,0 16 37087 3 x 35 29,3 - 37,1 1008,0 1900,0 2
37076 27 G 2,5 30,0 - 37,0 640,0 1521,0 14 37088 3 x 50 34,1 - 42,9 1440,0 2600,0 1
37077 37 G 2,5 34,0 - 37,5 720,0 1940,0 14 37089 4 x 10 20,9 - 26,5 384,0 1065,0 8
37090 4 x 25 28,9 - 36,6 960,0 1995,0 4

Dimensions and specifications may be changed without prior notice. (RF01)

Suitable accessories can be found in Chapter X.


Cable tie - T-WS

244
Allweather, Rubber and Liftcables

NEOPREN Command Cable flexible, colour or


number coded with support organ

Technical data Cable structure Properties


Special neoprene cable Bare copper-conductor, to Generally oil, flat and alkali resistant
adapted to DIN VDE 0250 DIN VDE 0295 cl.6 col.4, extra fine-wire,
with strain bearing support strand
Temperature range
BS 6360 cl.6, IEC 60228 cl.6
Core insulation of rubber
Note
G = with green-yellow conductor
F
flexing -25C to +60C Core identification to DIN VDE 0293-308 x = without green-yellow conductor
fixed installation -40C to +80C - up to 5 cores coloured AWG sizes are approximate equivalent
Nominal voltage U0/U 300/500 V - from 6 cores, black with continuous values. The actual cross-section is in mm.
Test voltage 3000 V white numbering Not suitable for a winding up and an
Minimum bending radius GN-YE conductor, 3 cores and above unwinding on spring or motor cable reels.
for continuous bending without forced Cores stranded in layers with Break resistance must be taken into
guiding operation 12,5x cable optimal lay-length consideration.
for flexing with forced guiding operation Support organ (hemp or sisal-string etc.), By the assembly the cables must be
20x cable and/or taping with load carrying thread as installed without torsion.
construction permits The mobility of the stranded core is
Outer sheath of neoprene not be affected by using of clamps.
Sheath colour black The occuring pulling forces are to be
The braking strength oft he carrying carried by the support organ.
element is depending on the number
of cores, the cross section of cores and
the construction of cable.

Application
As robust and weather resistant cable for machines, equipment and appliances, which are constantly exposed to the outdoor weather conditions (e.
g. building machinery, conveyor and hoist systems, dry docks etc.). They are ideal for use as control cable in trailing cables. They are also suitable in
dry, damp and wet areas for wall- and push-button panels and as power cable. The core insulation is ozone resistant and the outer sheath made of
chloroprene is hardly flammable and abrasion resistant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Tensile Cop. Weight AWG-No. Part no. No.cores x Outer Tensile Cop. Weight AWG-No.
cross-sec. approx. strength weight approx. cross-sec. approx. strength weight approx.
mm mm of susp. kg / km kg / km mm mm of susp. kg / km kg / km
strand in N strand in N
25001 2x1 7,5 300 19,0 90,0 18 25038 48 G 1,5 34,9 - 691,0 1510,0 16
25002 3G1 8,5 150 29,0 111,0 18 25039 50 G 1,5 36,7 - 720,0 1642,0 16
25003 4G1 9,7 300 38,0 141,0 18 25040 61 G 1,5 41,8 - 878,0 1950,0 16
25004 5G1 11,5 300 48,0 170,0 18 25041 2 x 2,5 10,0 300 48,0 142,0 14
25005 6G1 13,4 - 58,0 187,0 18 25042 3 G 2,5 10,5 300 72,0 172,0 14
25006 7G1 13,8 2290 67,0 204,0 18 25043 4 G 2,5 11,6 570 96,0 210,0 14
25007 9G1 15,8 2890 86,0 274,0 18 25044 5 G 2,5 12,9 380 120,0 255,0 14
25008 12 G 1 17,5 6740 115,0 389,0 18 25045 6 G 2,5 14,5 - 144,0 318,0 14
25009 16 G 1 19,2 570 154,0 432,0 18 25046 7 G 2,5 16,2 3460 168,0 383,0 14
25010 18 G 1 21,5 960 173,0 471,0 18 25075 8 G 2,5 16,8 3850 192,0 450,0 14
25011 19 G 1 22,0 - 182,0 565,0 18 25047 9 G 2,5 21,5 680 216,0 541,0 14
25012 20 G 1 22,4 600 192,0 590,0 18 25048 11 G 2,5 23,3 - 264,0 638,0 14
25013 24 G 1 23,6 2890 230,0 650,0 18 25049 12 G 2,5 25,4 6060 288,0 690,0 14
25074 30 G 1 24,6 - 290,0 785,0 18 25050 16 G 2,5 24,4 - 383,0 813,0 14
25014 36 G 1 29,0 960 346,0 910,0 18 25051 18 G 2,5 26,3 2290 432,0 891,0 14
25015 37 G 1 30,5 - 355,0 936,0 18 25052 19 G 2,5 27,5 - 456,0 946,0 14
25016 48 G 1 31,4 1440 461,0 1244,0 18 25053 24 G 2,5 30,5 6060 576,0 1221,0 14
25017 50 G 1 32,6 - 480,0 1296,0 18 25054 36 G 2,5 33,3 - 864,0 1737,0 14
25018 54 G 1 32,9 2500 518,0 1399,0 18 25055 37 G 2,5 40,8 2500 888,0 1784,0 14
25019 61 G 1 37,2 2290 586,0 1495,0 18 25056 48 G 2,5 41,9 - 1152,0 2500,0 14
25020 2 x 1,5 8,5 300 29,0 95,0 16 25057 50 G 2,5 43,3 - 1200,0 2630,0 14
25021 3 G 1,5 9,3 150 43,0 113,0 16 25058 61 G 2,5 49,3 - 1464,0 8100,0 14
25022 4 G 1,5 10,5 570 58,0 150,0 16 25059 3G4 13,6 - 115,0 372,0 12
25023 5 G 1,5 12,5 870 72,0 180,0 16 25060 4G4 15,0 1000 154,0 407,0 12
25024 6 G 1,5 14,3 - 86,0 245,0 16 25061 5G4 17,1 600 192,0 432,0 12
25025 7 G 1,5 14,8 2600 101,0 309,0 16 25062 7G4 21,5 - 269,0 495,0 12
25026 8 G 1,5 15,8 3460 115,0 333,0 16 25063 3G6 13,9 - 173,0 380,0 10
25027 9 G 1,5 17,7 3850 130,0 360,0 16 25064 4G6 15,2 1000 230,0 445,0 10
25028 10 G 1,5 18,5 450 144,0 405,0 16 25065 5G6 19,2 900 288,0 569,0 10
25029 11 G 1,5 20,1 - 158,0 458,0 16 25066 7G6 21,1 - 403,0 702,0 10
25030 12 G 1,5 21,6 7710 173,0 516,0 16 25067 3 G 10 18,1 - 288,0 530,0 8
25031 13 G 1,5 22,1 - 187,0 571,0 16 25068 4 G 10 20,6 1200 384,0 724,0 8
25032 15 G 1,5 22,8 680 216,0 590,0 16 25069 5 G 10 22,6 1500 480,0 923,0 8
25033 18 G 1,5 23,6 960 259,0 620,0 16 25070 7 G 10 27,4 - 672,0 1288,0 8
25034 19 G 1,5 24,1 860 274,0 670,0 16 25071 3 G 16 21,3 - 461,0 865,0 6
25035 24 G 1,5 27,0 3850 346,0 817,0 16 25072 4 G 16 25,2 1920 614,0 1028,0 6
25036 37 G 1,5 31,0 - 533,0 1220,0 16 25073 5 G 16 26,5 2400 768,0 1260,0 6
25037 42 G 1,5 33,0 3460 605,0 1380,0 16

Dimensions and specifications may be changed without prior notice. (RF01)

245
Allweather, Rubber and Liftcables

NSSHU heavy dusty rubber cable 0,6/1kV

Technical data Cable structure Properties


Rubber sheath cable to Tinned copper-conductor, to Ozone resistance
DIN VDE 0250 part 812 DIN VDE 0295 cl.5, fine-wire, High insulation resistance
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Resistant against hot penetration
flexing -25C to +80C Core insulation of rubber (EPR) Low abrasion
fixed installation -40C to +80C compound type 3GI3 to High notch resistant
Permissible operating temperature DIN VDE 0207 part 20 The code identification of a single core
at conductor +90C Core identification to DIN VDE 0293-308 sheathed of an insulated wire is black.
Nominal voltage U0/U 0,6/1 kV - up to 5 cores coloured Resistant against
Operating voltage in - from 6 cores, black with continuous oils
three-phase and one-phase a.c. white numbering fats and chemicals
U0/U 0,7/1,2 kV GN-YE conductor, 3 cores and above Tests
Direct current system Cores stranded in layers with Behaviour in fire
U0/U 0,9/1,8 kV optimal lay-length to DIN VDE 0482-332-1-2
Test voltage 3000 V Inner sheath of rubber DIN EN 60332-2-1, IEC 60332-1 (equivalent
Insulation resistance compound type GM1b to DIN VDE 0472 part 804 test method B)
min. 20 MOhm x km DIN VDE 0207 part 21 Oil resistant to DIN EN 60811-404
Tensile strength Outer sheath of rubber
statical load: total compound type 5GM5 to Note
cross-section x15 N/mm DIN VDE 0207 part 21 G = with green-yellow conductor
Minimum bending radius Sheath colour yellow x = without green-yellow conductor
fixed installation 4x cable AWG sizes are approximate equivalent
flexing 10x cable values. The actual cross-section is in mm.
without forced operation 15x cable

Application
Are suited as a connecting cable for very high mechanical stress in underground mining and tools for use in industries and outdoor use. They are also
used for mining industry, surface mining, stone-pits, on building sites, outdoors as well as indoors. Suitable for fixed installation on plaster in dry,
damp and wet areas. A long duration of life is guaranteed under extreme operating conditions. Not suitable for drumming and use in all types of
machinery, such as robots, handling units and energy transfer units, where constant mobility is essential. The insulation of a plastic-rubber compound
on EPR basis improves the resistance to ozone in order to avoid the formation of cracks due to ozone and insulation damages in switch-boards.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. max. mm weight approx. cross-sec. max. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
38001 1 x 16 13,5 154,0 336,0 6 38023 4 G 35 42,5 1344,0 2777,0 2
38002 1 x 25 16,5 240,0 473,0 4 38024 4 G 50 49,0 1920,0 3817,0 1
38003 1 x 35 18,0 336,0 635,0 2 38025 4 G 70 53,5 2688,0 5071,0 2/0
38004 1 x 50 20,0 480,0 866,0 1 38026 4 G 95 61,5 3648,0 6636,0 3/0
38005 1 x 70 22,0 672,0 1145,0 2/0 38027 4 G 120 68,0 4608,0 7000,0 4/0
38006 1 x 95 25,0 912,0 1475,0 3/0 38028 5 G 1,5 17,0 72,0 252,0 16
38007 1 x 120 27,5 1152,0 1832,0 4/0 38029 5 G 2,5 20,0 120,0 362,0 14
38008 1 x 150 30,0 1440,0 2000,0 300 kcmil 38030 5G4 23,0 192,0 509,0 12
38009 1 x 185 34,0 1776,0 2450,0 350 kcmil 38031 5G6 26,5 288,0 798,0 10
38010 1 x 240 37,0 2304,0 3190,0 500 kcmil 38035 5 G 10 30,0 480,0 1120,0 8
38011 2 x 2,5 16,0 48,0 205,0 14 38036 5 G 16 34,0 768,0 1680,0 6
38012 3 G 1,5 15,0 43,0 173,0 16 38037 5 G 25 42,0 1200,0 2430,0 4
38013 3 G 2,5 16,5 72,0 247,0 14 38038 7 G 1,5 19,5 101,0 470,0 16
38014 3G4 20,0 115,0 336,0 12 38032 7 G 2,5 21,5 168,0 546,0 14
38015 3G6 22,0 173,0 520,0 10 38039 10 G 1,5 22,0 144,0 560,0 16
38016 4 G 1,5 16,0 58,0 210,0 16 38033 12 G 2,5 28,0 288,0 851,0 14
38017 4 G 2,5 19,0 96,0 305,0 14 38040 18 G 2,5 33,0 432,0 1230,0 14
38018 4G4 21,5 154,0 415,0 12 38034 19 G 2,5 33,5 466,0 1260,0 14
38019 4G6 23,0 230,0 641,0 10
38020 4 G 10 27,5 384,0 1113,0 8
38021 4 G 16 37,0 614,0 1412,0 6
38022 4 G 25 39,0 960,0 2095,0 4

Dimensions and specifications may be changed without prior notice. (RF01)

246
Allweather, Rubber and Liftcables

LIFT-TRAGO-30 / -60 lift hoist control cable, pendal length 30m resp. 60m

Technical data Cable structure Properties


Lift hoist control cables with strain bearing Bare copper-conductor, to Extensively oil resistant
element to IEC 60227-6 edition 2001-06 DIN VDE 0295 cl.5, fine-wire, Chemical Resistance - see table
and adapted to DIN VDE 0285-525-2-51 / BS 6360 cl.5, IEC 60228 cl.5 Technical Informations
DIN EN 50525-2-51 Core insualtion of special PVC The materials used in manufacture are
Temperature range compound type TI2 to cadmium-free and contain no silicone F
flexing -5C to +50C DIN VDE 0207-363-3 / DIN EN 50363-3 and free from substances harmful to
fixed installation -40C to +70C Core identification to DIN VDE 0293 the wetting properties of lacquers
Max. conductor temperature black cores with continuous white Tests
under load +70C numbering PVC self-extinguishing and flame retardant
circuit conditions +150C GN-YE conductor in the outer layer acc. to DIN VDE 0482-332-1-2,
Nominal voltage Cores stranded with optimal lay-length DIN EN 60332-1-2/IEC 60332-1 (equivalent
U0/U 300/500 V acc. to the number of cores in one DIN VDE 0472 part 804 test method B)
Test voltage 3000 V or two layers, over a central Suspension
Breakdown voltage strand of textile. Note
min. 6000 V LIFT-TRAGO-30 - Fleece wrapping G = with green-yellow conductor
Minimum bending radius LIFT-TRAGO-60 - Support braiding of AWG sizes are approximate equivalent
20x cable textile suspension strands values. The actual cross-section is in mm.
Insulation resistance Outer sheath of special PVC Cable for pendal length 60 m and above
min. 20 MOhm x km compound type TM2 to available on request.
Radiation resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1
up to 80x106 cJ/kg (up to 80 Mrad) Colour black (RAL 9005)

Application
These cables are used as control or feeder cables in lifts and hoists.
30 m pendal length - LIFT-TRAGO-30
60 m pendal length - LIFT-TRAGO-60
Suspension height for medium mechanical stresses in dry and moist rooms.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
LIFT-TRAGO-30
Part no. No.cores x Outer Cop. Weight Support core Pendal AWG-No.
cross-sec. approx. mm weight approx. kg / km length
mm kg / km max. m
25259 7G1 11,5 67,0 170,0 Textile 30 18
25260 12 G 1 15,7 115,0 325,0 Textile 30 18
25261 18 G 1 16,1 173,0 390,0 Textile 30 18
25262 24 G 1 19,2 230,0 530,0 Textile 30 18

LIFT-TRAGO-60
Part no. No.cores x Outer Cop. Weight Support core Pendal AWG-No.
cross-sec. approx. mm weight approx. kg / km length
mm kg / km max. m
25263 7G1 12,3 67,0 185,0 Textile 60 18
25264 12 G 1 16,2 115,0 335,0 Textile 60 18
25265 18 G 1 16,7 173,0 400,0 Textile 60 18
25266 24 G 1 19,8 230,0 540,0 Textile 60 18
25267 30 G 1 22,5 288,0 690,0 Textile 60 18
25268 36 G 1 28,2 346,0 930,0 Steel 60 18

Dimensions and specifications may be changed without prior notice. (RF01)

Suitable accessories can be found in Chapter X.


Cable tie - T-WS

247
Allweather, Rubber and Liftcables

TRAGO / Lift-2S Lift and Hoist Control Cables 300/500 V

Technical data Cable structure Properties


Lift hoist control cables with strain bearing Bare copper-conductor, to The materials used in manufacture are
element Special PVC-compound for core DIN VDE 0295 cl.6, extra fine-wire, cadmium-free and contain no silicone
and sheath, adapted to DIN VDE 0250 BS 6360 cl.6, IEC 60228 cl.6 and free from substances harmful to
Temperature range Core insualtion of special PVC, TI2 to the wetting properties of lacquers
flexing -15C to +70C DIN VDE 0207-363-3 / DIN EN 50363-3 UV-resistant
fixed installation -40C to +70C Core identification to DIN VDE 0293 Tests
Max. conductor temperature GN-YE conductor PVC self-extinguishing and flame retardant
under load +70C Special hemp support braid acc. to DIN VDE 0482-332-1-2,
circuit conditions +150C for Trago type with central DIN EN 60332-1-2, IEC 60332-1 (equivalent
Nominal voltage support core of hemp DIN VDE 0472 part 804 test method B)
U0/U 300/500 V for Lift-2S type with 2 outer
Test voltage 3000 V steel support wires Note
Breakdown voltage Cores stranded in layers with G = with green-yellow conductor
min. 6000 V optimal lay-length AWG sizes are approximate equivalent
Minimum bending radius Multi-layer wrapping functioning as a values. The actual cross-section is in mm.
20x cable support braid
Outer sheath of special PVC TM2 to
DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Sheath colour black (RAL 9005)

Application
These cables are used as control or feeder cables in lifts and hoists. The special attention given to both production and material quality for these cables
has made them ideal even for use under extreme conditions. HELUKABEL-Lift-2S has also proven itself to be ideally suited for installation in conveyor
systems and manual control units. The external steel support wires can be dismounted without damaging the cable insulation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TRAGO with central support
Part no. No.cores x Outer Cop. Weight Support core Pendal AWG-No.
cross-sec. approx. mm weight approx. kg / km length
mm kg / km max. m
25080 7 G 0,75 15,4 50,0 290,0 Hemp 250 19
25081 12 G 0,75 19,2 86,0 360,0 Hemp 220 19
25082 18 G 0,75 21,0 130,0 455,0 Hemp 110 19
25083 24 G 0,75 23,0 173,0 535,0 Hemp 90 19
25084 7G1 14,9 67,0 222,0 Hemp 80 18
25085 12 G 1 20,0 115,0 415,0 Hemp 80 18
25086 18 G 1 21,4 173,0 450,0 Hemp 70 18
25087 20 G 1 21,6 192,0 490,0 Hemp 70 18
25088 24 G 1 23,2 230,0 605,0 Hemp 60 18
25089 36 G 1 26,1 346,0 950,0 Hemp 90 18

Lift-2S with 2 external support cores


Part no. No.cores x Outer Cop. Weight Support core Pendal AWG-No.
cross-sec. approx. mm weight approx. kg / km length
mm kg / km max. m
25091 12 G 1 13,5 115,2 446,0 Steel 50 18
25092 18 G 1 16,2 172,8 528,0 Steel 50 18
25093 25 G 1 19,0 240,0 660,0 Steel 50 18
25094 30 G 1 21,9 288,0 760,0 Steel 50 18
25095 8 G 1,5 14,7 115,0 425,0 Steel 50 16
25096 12 G 1,5 16,0 172,8 505,0 Steel 50 16
25097 15 G 1,5 19,5 230,0 575,0 Steel 50 16
25098 18 G 1,5 19,3 259,0 640,0 Steel 50 16
25099 20 G 1,5 19,5 288,0 715,0 Steel 50 16
25100 24 G 1,5 22,5 346,0 820,0 Steel 50 16

Dimensions and specifications may be changed without prior notice. (RF01)

Suitable accessories can be found in Chapter X.


Cable tie - T-WS

248
Allweather, Rubber and Liftcables

Bauliftkabel B101 / B102 / B103 to be used at plant elevators

Technical data Cable structure Properties


Temperature range Bare copper-conductor, extra fine-wire, Sheath UV-resistant
flexing -10C to +80C high flexible In carriage version with special support
Nominal voltage Core insulation of plastic, braiding and with PUR sheath particularly
control cores 300/500 V flexible at low temperatures resistant to wear, oil, hydrolysis and
power supply cores 0,6/1 kV Core identification black cores with microbial attack F
A.c. test voltage, 50 Hz continuous white numbering
control cores 1500 V GN-YE conductor Note
power supply cores 3000 V Outer sheath of special plastic, Optional separate copper screening
Minimum bending radius flexible at low temperatures of the control cores
10x cable Sheath colour black

Application
These hybrid cables are used for power supply and control of vertical lifts in the construction industry. There are 3 cable versions.
Bauliftkabel B101: Here the cable is drawn vertically from a drum as a drag cable via the load platform. The load platform pulls the cable along as
it moves up. During the downwards motion the cable returns to the drum automatically. Our special versions are used at heights of up to about 150
m.
Bauliftkabel B102: For greater heights, a so-called carriage version is employed, in which the cable is fed at the centre of the tower, i. e. half the
way up.
Bauliftkabel B103: Here the cable is guided via a spring-loaded drum. These vertical construction lifts are used during new construction and
renovation work on high buildings. The rack lattice elements are fastened at intervals to the exterior facade.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Bauliftkabel B101 Bauliftkabel B102
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
73519 5 G 2,5 + 10 x 1,0 20,0 220,0 306,0 - 74293 4 G 16 + 1 x 2,5 + 2 x 2 x 1,0 28,5 830,0 1080,0 6
73913 5 G 2,5 + 11 x 1,0 20,0 225,6 320,0 14 74670 4 G 16 + 1 x 2,5 + 2 x 2 x 1,0 28,5 787,0 1080,0 6
70402 3 G 4 + 7 x 1,0 17,4 184,0 360,0 12 74297 4 G 25 + 1 x 2,5 + 2 x 2 x 1,0 33,4 1176,0 1500,0 4
70931 4 G 6 + 9 x 1,0 20,5 330,0 555,0 10 78122 4 G 35 + 4 x 2,5 + 2 x 2 x 1,0 38,0 1500,0 1850,0 2
70377 4 G 6 + 10 x 1,0 21,0 340,0 575,0 10 + 1 x 1,0
71901 4 G 6 + 15 x 1,0 22,0 388,0 625,0 10
71369 4 G 10 + 10 x 1,0 25,0 480,0 870,0 8 Bauliftkabel B103
78123 4 G 16 + 6 x 1,0 26,1 700,0 1250,0 6 Part no. No.cores x Outer Cop. Weight AWG-No.
78124 4 G 16 + 10 x 1,0 29,0 710,0 1300,0 6 cross-sec. approx. weight approx.
78125 4 G 16 + 15 x 1,0 31,5 760,0 1380,0 6 mm mm kg / km kg / km
73726 4 G 16 + 1 x 2,5 + 4 x 1,0 28,5 830,0 1460,0 6 77532 4 G 2,5 + 3 x 1,0 13,0 125,0 230,0 14
77538 4 G 2,5 + 3 x 1,0 15,3 125,0 280,0 14

Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable tie - T-WS

249
Allweather, Rubber and Liftcables

HELUSPREADER YSLT-J spreader cable for vertical basket enterprise

Technical data Cable structure Properties


Special cable adapted to Bare copper-conductor, to weather resistant
DIN VDE 0250 DIN VDE 0295 cl.5 or cl.6, fine-wire UV-resistant
Temperature range or extra-fine-wire, BS 6360 cl.5 or cl.6, high abrasion resistance
flexing -20C to +60C IEC 60228 cl.5 or cl.6
fixed installation -20C to +60C Core insulation of special EPR Note
max. Operating temperature Core identification to DIN VDE 0293 G = with green-yellow conductor
at conductor +90C black cores with continuous white Delivery on request:
max. Short circuit temperature numbering also as -K model, temperature range
at conductor +150C GN-YE conductor -40C to +80C
Nominal voltage U0/U 300/500 V Cores laid-up in lay of length, further dimensions and special designs
max. Tensile load 2000 N stranding with optimal length AWG sizes are approximate equivalent
Minimum bending radius of twists around a Kevlar element values. The actual cross-section is in mm
15x cable Outer sheath of special polychloropren
Current carrying capacity Sheath colour black (RAL 9005)
to DIN VDE 0298 part 4

Application
As Spreader cable with high mechanical stresses in vertical basket operation in dry, moist, wet environment and in open air. Please note that at the
installation the cable must be placed counterwise and free of twist into the basket.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight Tensile AWG-No. Part no. No.cores x Outer Cop. Weight Tensile AWG-No.
cross-sec. min. - max. weight approx. strain cross-sec. min. - max. weight approx. strain
mm mm kg / km kg / km max. N mm mm kg / km kg / km max. N
40160 36 G 2,5 38,1 - 41,0 864,0 2500,0 2000 14 40164 36 G 3,3 42,4 - 45,5 1140,0 3200,0 2000 12
40161 42 G 2,5 40,8 - 43,8 1008,0 3000,0 2000 14 40165 42 G 3,3 46,6 - 49,6 1330,0 3750,0 2000 12
40162 48 G 2,5 45,7 - 48,7 1152,0 3650,0 2000 14 40166 48 G 3,3 52,0 - 55,0 1521,0 4450,0 2000 12
40163 54 G 2,5 47,0 - 51,0 1296,0 4100,0 2000 14 40167 54 G 3,3 56,6 - 60,0 1711,0 5000,0 2000 12

Dimensions and specifications may be changed without prior notice. (RG01)

Suitable accessories can be found in Chapter X.


Cable tie - T-WS

250
TRAILING CABLES

3
in

E
VD eld 29
ng

x
xe
ex

VD
ed
U

R/ shi E 0
xi
- fi
- fl

./
0 /

le

ed
i

no
H A ed / VD
-f

-f
U
C)

C)

ge

us

us

CS REG
e n es /
(

e
lta

di

di

se
re

re

t
fre

ut tan

r
n
ra

ra

co
tu

tu

u
vo

E
ai
n-

or
sis
ra

ra

A
d
ch
al

ge
in

in
pe

pe

re
do
re
in

ge
nd

nd

ag
lo

lo

re
V-
m

L/
om

Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
N
Trailing Cables

TROMMPUR -40 bis +80 -40 to +80 300/500 10x 10x X X X X 254

Flugzeugheber-T -20 to +80 -20 to +80 300/500 15x 15x X X 255

NSHTU -35 to +70 -40 to +70 0.6/1 kV 7.5x 7.5x X X X X 256

(N)SHTU-V -25 to +80 -25 to +80 0.6/1 kV 7.5x 7.5x X X 257

(N)TSCGEWU -20 to +60 -20 to +80 6-20 kV 15x 15x X X 258

The selection table is intended as an initial orientation. G


Please see the relevant page of the catalogue for detailed information on the product properties.

253
Trailing Cables

TROMMPUR PUR trailing and control cable, halogen-free

Technical data Cable structure Properties


Special PUR insulation and sheath Bare copper-conductor, to High flexibility at low temperatures
adapted to DIN VDE 0250 DIN VDE 0295 cl.6 col.4, extra fine-wire, Usable for foodstuffs
Strain bearing support strand BS 6360 cl.6, IEC 60228 cl.6 Abrasion and tear resistant
Temperature range Core insulation of special PUR Loadable under torsional stress
-40C to +80C Support core Resistant to
(up to +100C for short periods) Core identification to DIN VDE 0293 Oils and fats
Nominal voltage (flexible cables) Non-alcoholic fuels and kerosene
up to 1 mm U0/U 300/500 V Cores stranded in layers with Atmospheric influences
from 1,5 mm U0/U 450/750 V optimal lay-length UV-radiation
Test voltage Core wrapping with fleece Oxygen and ozone
up to 1 mm = 2000 V Support braiding of synthetic fibres Microbes and rotting
from 1,5 mm = 2500 V Outer sheath of halogen-free PUR Sea and waste water
Breakdown voltage Sheath colour orange Vibrations
up to 1 mm = 4000 V
from 1,5 mm = 5000 V Note
Insulation resistance G = with green-yellow conductor
min. 20 MOhm x km AWG sizes are approximate equivalent
Minimum bending radius values. The actual cross-section is in mm.
10x cable
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)

Application
TROMMPUR has taken the development of the neoprene type cables one step further. It is a robust, all-weather cable, halogen-free, tear and abrasion
resistant and suitable for use in drag-chains, in ship docks, on building sites, for conveyor systems, in mining, for tunnels and roadbuilding. For the
connecting the ski lift terminal positions to the control unit, surveillance of the joining rods in ski lift cables, as feeder cables for very high currents as
for example in pump engineering, mining, locomotive and rail-carriage construction, for oil rig platforms, emergency power generators etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight Breaking strain AWG-No.


cross-sec. app. mm weight app. kg / km ca. kp
mm kg / km
26035 14 G 0,75 16,5 154,0 320,0 250 19
26036 12 G 1 17,5 115,0 300,0 500 18
26037 18 G 1 23,0 173,0 480,0 500 18
26038 3 G 1,5 9,5 43,0 110,0 200 16
26039 5 G 1,5 12,5 72,0 220,0 200 16
26040 7 G 1,5 15,5 101,0 270,0 250 16
26041 12 G 1,5 21,0 173,0 450,0 750 16
26042 18 G 1,5 27,0 259,0 620,0 750 16
26043 24 G 1,5 30,0 346,0 850,0 750 16
26044 30 G 1,5 34,0 533,0 1100,0 750 16
26045 42 G 1,5 40,0 605,0 1600,0 750 16
26046 4 G 2,5 14,0 96,0 250,0 200 14
26047 5 G 2,5 15,0 120,0 280,0 250 14
26048 7 G 2,5 18,0 168,0 360,0 300 14
26049 12 G 2,5 25,0 288,0 740,0 750 14
26050 24 G 2,5 36,0 576,0 1400,0 750 14
26051 30 G 2,5 40,0 864,0 1740,0 750 14
26052 36 G 2,5 44,0 998,0 2050,0 750 14
26053 7G4 22,0 269,0 600,0 500 12
26054 4 G 10 22,0 384,0 650,0 500 8
26055 4 G 16 27,0 614,0 1100,0 500 6
26059 5 G 16 34,0 768,0 1600,0 750 6
26056 4 G 25 30,0 960,0 1600,0 500 4
26057 4 G 35 36,0 1344,0 2050,0 1000 2
26058 4 G 50 42,0 1920,0 2800,0 1000 1

Dimensions and specifications may be changed without prior notice. (RG01)

Suitable accessories can be found in Chapter X.


Tool - HAM 1

254
Trailing Cables

Flugzeugheber-T trailing, PUR

Technical data Cable structure Properties


Temperature range Part no. 70736 PUR outer sheath: low adhesion, extremely,
flexing -20C to +80C Bare copper-conductor, to abrasion resistant, halogen-free, resistant
Nominal voltage DIN VDE 0295 cl.6, extra fine-wire, to UV, oil, hydrolysis and microbial attack
control cores 300/500 V BS 6360 cl.6, IEC 60228 cl.6
power supply cores 600/1000 V Power supply cores (4 mm) and
A.C. test voltage, 50 Hz control cores (0,75 mm)
control cores 1500 V - Core insulation of cold flexible special PVC
power supply cores 4000 V
Minimum bending radius
- Core identification black with numbering
4 mm No.1-5 + 0,75 mm No.6-20
G
for flexible installation 15x cable Data pair ( 0,34 mm)
- Core insulation data pair of polyethylene
- Core identification to DIN 47100
- Cores twisted in pairs
- Foil wrapping
- Tinned copper braided screen,
approx. 85% coverage
- Inner sheath of cold flexible special PVC
Cores stranded with elements
Inner sheath of cold flexible special PVC
Outer sheath of PUR
with integrated support braiding
Sheath colour grey (RAL 7001)
Part no. 77548
Bare copper-conductor, to
DIN VDE 0295 cl.6, extra fine-wire,
BS 6360 cl.6, IEC 60228 cl.6
Power supply cores (2,5 mm) and
control cores (1 mm)
- Core insulation of TPE-E
- Core identification black with numbering
- GN-YE conductor
Data pair ( 0,34 mm)
- Core insulation of polyethylene
- Core identification to DIN 47100
- Cores twisted in pairs
- Foil wrapping of aluminium-coated
polyester
- Tinned copper braided screen,
approx. 85% coverage
Cores stranded with elements
Outer sheath of PUR
with integrated support braiding
Sheath colour orange (RAL 2003)

Application
This hybrid cable is designed for the aircraft industry, and contains cores for power supply, control cores, and cores for a positioning laser. The cable
is used to control and position a support robot, which absorbs loads at specific points when loading extremely heavy items, for example during loading
of aircraft assemblies in large transport aircraft of the Airbus industry. The cable is trailing, UV and weather-resistant, and is provided with an extremely
wear-resistant and petrol-resistant special sheath. Part no. 77548 is designed for similar applications, as a load-reducing lifter in aircraft assembly.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
70736 5 x 4 + 5 x 3 G 0,75 + 2 x 2 x 25,6 390,0 600,0 12 77548 5 x 2,5 + 18 G 1,0 + 4 x 2 x 0,34 27,0 461,0 750,0 14
0,34

Dimensions and specifications may be changed without prior notice.

255
Trailing Cables

NSHTU drum cable, VDE approved

Technical data Cable structure Properties


Special-crane-drum cable to Tinned copper-conductor, to Designed and developed for horizontal
DIN VDE 0250 part 814 DIN VDE 0295 cl.5, fine-wire, drum-operation
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Permissible running speed up to
flexing -35C to +70C Core insulation of rubber max. 120 m/min
fixed installation -40C to +70C compound type GI1 to Polychloroprene-rubber (neoprene)-sheath,
max. Temperature at conductor DIN VDE 0207 part 20 extremely cold resistant
in operation +60C Core identification to DIN VDE 0293 Due to the neoprene outer sheath,
in short-circuit +200C - up to 5 cores coloured the cables is resistant against ozone
Nominal voltage U0/U 0,6/1 kV - from 6 cores, black with continuous and radiation, oils, acids, fats, gazoline,
max. permissible operating voltages white numbering solvents and chemicals
in three-phase and one-phase Cores stranded (without elongated central During the installation and operation the
a.c. system U0/U 0,7/1,2 kV core) with max. lay-length of 8x over the tensile stress on conductor may not increase
in direct current system stranding layers 15 N/mm
U0/U 0,9/1,8 kV Textile tape Accelaration not more than 0,4 m/s
Test voltage 2500 V Textile braiding as protection against torsion, During operation, 1-2 convolutions should
Insulation resistance embedded in inner filling sheath remain on the operating drum
min. 10 MOhm x km Outer sheath of neoprene In case of high mechanical stress, especially
Minimum bending radius compound type 5GM2 to of high dynamic tensile stress result high
7,5 x cable DIN VDE 0207 part 21 accelaration, the permissible stress must be
Radiation resistance Sheath colour black defined in each case
up to 20x106 cJ/kg (up to 20 Mrad) Tests
Behaviour in fire
to DIN VDE 0482-332-1-2
DIN EN 60332-2-1, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Oil resistant acc. to
DIN VDE 0473-811-404,DIN EN 60811-404

Note
G = with green-yellow conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Trailing cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous tensile and
torsional stress, for building machinery, conveyors, shifts and cranes. They are used as robust and all weather resistant cables of roughest operations
in mining and in flexible handling equipment and railway motors. The cables are suitable for outdoor installation in dry, damp and wet places as well
in open air. For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for reeling
cables. Please read the installation instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
26001 3 G 1,5 13,6 47,0 236,0 16 26019 4G4 18,5 158,0 510,0 12
26029 4 G 1,5 14,0 58,0 274,0 16 26030 5G4 21,5 220,0 635,0 12
26002 5 G 1,5 14,5 81,0 316,0 16 26020 4G6 21,0 241,0 650,0 10
26003 7 G 1,5 18,8 115,0 440,0 16 26031 5G6 23,5 317,0 800,0 10
26004 12 G 1,5 21,0 196,0 606,0 16 26021 4 G 10 26,0 404,0 1010,0 8
26005 16 G 1,5 24,5 259,0 696,0 16 26022 5 G 10 28,0 508,0 1200,0 8
26006 18 G 1,5 25,5 271,0 750,0 16 26023 4 G 16 29,0 642,0 1300,0 6
26007 24 G 1,5 27,5 390,0 1150,0 16 26032 5 G 16 31,5 768,0 1700,0 6
26008 30 G 1,5 29,5 432,0 1325,0 16 26024 4 G 25 35,0 1005,0 2000,0 4
26009 3 G 2,5 15,3 74,0 305,0 14 26025 4 G 35 37,5 1344,0 2610,0 2
26010 4 G 2,5 16,5 98,0 350,0 14 26026 4 G 50 44,5 2010,0 3500,0 1
26011 5 G 2,5 17,5 124,0 465,0 14 26027 4 G 70 49,0 2688,0 4600,0 2/0
26012 7 G 2,5 20,0 168,0 576,0 14 26028 4 G 95 56,0 3648,0 6100,0 3/0
26013 12 G 2,5 23,5 308,0 850,0 14
26014 18 G 2,5 28,0 451,0 1181,0 14
26015 24 G 2,5 32,5 615,0 1550,0 14
26016 30 G 2,5 34,0 770,0 1810,0 14
26017 40 G 2,5 42,5 1080,0 3110,0 14
26018 50 G 2,5 46,5 1200,0 3200,0 14

Dimensions and specifications may be changed without prior notice. (RG01)

256
Trailing Cables

(N)SHTU-V Trailing-Cable

Technical data Cable structure Properties


Special trailing cable adapted to Tinned copper-conductor, to Permitted running speed up
DIN VDE 0250, Part 814 DIN VDE 0295 cl.5, fine-wire, 180 m/min
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Highly resistant to acids, fats,
flexing -25C to +80C Core insulation of special rubber gasoline, solvents and chemicals
max. Temperature at conductor compound type 3GI3 to During installation and operation,
in operation +90C DIN VDE 207 part 20 the tensile stress must not exceed

G
in short-circuit +250C Core identification to DIN VDE 0293-308 30 N/mm
Nominal voltage U0/U 0,6/1 kV (HD 308 S2) Tests
max. permissible operating voltage Cores stranded (without elongated Behaviour in fire
in three-phase and one-phase central core) with max. lay-length of to DIN VDE 0482-332-1-2
a.c. system U0/U 0,7/1,2 kV 8x over the stranded layers) DIN EN 60332-2-1, IEC 60332-1 (equivalent
in direct current system Depending on dimension/structure DIN VDE 0472 part 804 test method B)
U0/U 0,9/1,8 kV with Kevlar fillers Oil resistant to
Test voltage 4 kV Inner sheathof special rubber DIN VDE 0473-811-404,DIN EN 60811-404
Insulation resistance compound type 5GM5 to
min. 10 MOhm x km DIN VDE 0207 part 21 Note
Minimum bending radius Torsion protection between AWG sizes are approximate equivalent
7,5x cable inner and outer sheath values. The actual cross-section is in mm.
Outer sheath of special rubber
compound type 5GM5 to
DIN VDE 0207 part 21
Sheath colour yellow

Application
For vertical drum operation under extreme mechanical stress and on moving cable carrieres. Used as a rugged feeder to construction machines,
conveyor, transport and crane systems in dry, damp, wet environments and outdoors. For applications that go beyond standard solutions we recommend
you to our specially developed questionnaire for reeling cables. Please note installation instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Power supply Cable Control Cable (Kevlar fillers)
Part no. No.cores x Outer Cop. Weight Tensile AWG-No. Part no. No.cores x Outer Cop. Weight Tensile AWG-No.
cross-sec. min. - max. weight app. strain cross-sec. min. - max. weight app. strain
mm mm kg / km kg / km max. N mm mm kg / km kg / km max. N
31040 3 G 1,5 10,9 - 13,6 45,0 191,0 130 16 31078 49 G 1 31,0 - 34,5 470,0 1420,0 3450 18
31041 3 G 2,5 12,3 - 14,8 74,0 240,0 220 14 31079 7 G 1,5 14,6 - 16,9 115,0 320,0 2318 16
31042 3G4 14,9 - 17,6 115,0 362,0 360 12 31080 12 G 1,5 20,6 - 23,4 196,0 620,0 2540 16
31043 3G6 16,2 - 18,9 173,0 450,0 540 10 31081 18 G 1,5 20,3 - 22,9 271,0 650,0 2810 16
31044 3 G 10 19,6 - 22,6 288,0 682,0 900 8 31082 24 G 1,5 24,2 - 27,4 390,0 930,0 3080 16
31045 3 G 16 21,8 - 24,9 461,0 890,0 1440 6 31083 30 G 1,5 27,7 - 31,1 432,0 1190,0 3350 16
31046 3 G 25 27,5 - 30,8 720,0 1200,0 2250 4 31084 36 G 1,5 27,9 - 31,3 518,0 1240,0 3620 16
31047 3 x 50 + 3 G 25/3 36,9 - 40,6 1685,0 2810,0 4500 1 31085 44 G 1,5 31,2 - 34,8 634,0 1530,0 3980 16
31048 3 x 70 + 3 G 35/3 40,4 - 44,4 2355,0 3760,0 6300 2/0 31086 48 G 1,5 31,8 - 35,4 691,0 1610,0 4160 16
31049 3 x 95 + 3 G 50/3 46,6 - 50,8 3215,0 4700,0 8550 3/0 31087 56 G 1,5 35,9 - 39,7 807,0 2020,0 4520 16
31050 3 x 120 + 3 G 70/3 50,8 - 55,2 4130,0 5950,0 10800 4/0 31088 7 G 2,5 17,5 - 19,8 168,0 480,0 2520 14
31051 3 x 150 + 3 G 70/3 55,4 - 60,0 4990,0 7050,0 13500 300 kcmil 31089 12 G 2,5 23,8 - 26,7 308,0 915,0 2900 14
31090 18 G 2,5 23,4 - 26,2 451,0 945,0 3350 14
31052 3 x 185 + 3 G 95/3 60,8 - 65,7 6250,0 8800,0 16650 350 kcmil
31091 24 G 2,5 28,2 - 31,1 615,0 1330,0 3800 14
31053 3 x 240 + 3 G 120/3 68,8 - 74,0 8065,0 11700,0 21600 500 kcmil
31092 30 G 2,5 31,1 - 34,4 770,0 1615,0 4250 14
31054 4 G 1,5 11,8 - 14,5 58,0 220,0 180 16
31093 36 G 2,5 31,3 - 34,7 866,0 1710,0 4680 14
31055 4 G 2,5 14,4 - 17,1 99,0 330,0 300 14
31094 44 G 2,5 36,2 - 40,2 1057,0 2240,0 5250 14
31056 4G4 16,2 - 18,8 158,0 440,0 480 12 31095 48 G 2,5 37,2 - 41,0 1153,0 2410,0 5550 14
31057 4G6 17,4 - 20,2 241,0 530,0 720 10 31096 56 G 2,5 41,6 - 46,0 1344,0 2930,0 6150 14
31058 4 G 10 24,4 - 21,3 404,0 835,0 1200 8
31059 4 G 16 24,7 - 27,9 642,0 1175,0 1920 6
31060 4 G 25 31,4 - 34,9 1005,0 1850,0 3000 4
31061 4 G 35 37,5 - 33,9 1344,0 2250,0 4200 2
31062 4 G 50 40,3 - 44,2 2010,0 3210,0 6000 1
31063 4 G 70 44,5 - 48,6 2687,0 4210,0 8400 2/0
31064 4 G 95 51,1 - 55,5 3646,0 5550,0 11400 3/0
31065 4 G 120 57,4 - 62,0 4605,0 7010,0 14400 4/0
31066 4 G 150 62,6 - 67,6 5765,0 8450,0 18000 300 kcmil
31067 4 G 185 68,1 - 73,2 7110,0 10000,0 22200 350 kcmil
31068 5 G 1,5 12,8 - 15,5 73,0 258,0 220 16
31069 5 G 2,5 15,5 - 18,2 124,0 389,0 370 14
31070 5G4 17,4 - 20,2 220,0 511,0 600 12
31071 5G6 19,6 - 22,7 317,0 688,0 900 10
31072 5 G 10 23,2 - 26,3 508,0 1002,0 1500 8
31073 5 G 16 26,7 - 30,2 768,0 1395,0 2400 6
31074 5 G 25 34,1 - 37,7 1200,0 2205,0 3750 4
31075 5 G 35 38,3 - 42,2 1680,0 2960,0 5250 2
31076 5 G 50 43,8 - 47,8 2400,0 3950,0 7500 1
31077 5 G 70 50,2 - 54,6 3360,0 5455,0 10500 2/0

Dimensions and specifications may be changed without prior notice. (RG01)

257
Trailing Cables

(N)TSCGEWU extremely torsionally stiff

Technical data Cable structure Properties


Medium voltage power cable adapted to Tinned copper-conductor, to maximum permissible speed 200 m/min is
VDE 0250 part 813 DIN VDE 0295 cl.5, fine-wire, allowed when operating drums in one
Temperature range BS 6360 cl.5, IEC 60228 cl.5 direction
flexing -20C to +60C Inner semi-conducting layer extremly torsion resistant
fixed installation -20C to +80C Core insulation of HEPR resistant against oils and fats, athmosperic
Nominal voltages Outer semi-conducting layer exposure and UV-radiation
U0/U 3,6/6 kV Ground conductor with semi-conductive layer
U0/U 6/10 kV Cores concentrically stranded Note
U0/U 8,7/15 kV Inner sheath, sheath colour red Further dimensions and
U0/U 12/20 kV Antitorsional protection special designs on request
Operating voltages max. Outer sheath of chloroprene rubber
3,6/6 kV = 4,2/7,2 kV compound type 5GM3
6/10 kV = 6,9/12 kV Sheath colour red
8,7/15 kV = 10,4/18 kV
12/20 kV = 13,9/24 kV
Test voltages
3,6/6 kV = 11 kV
6/10 kV = 17 kV
8,7/15 kV = 24 kV
12/20 kV = 29 kV
Minimum bending radius
15x outer

Application
Reeling medium voltage supply train for use in high mechanical stresses, such as in in container cranes or large mobile equipment as well as excavators
in the mining industry for days, in dry, damp, wet areas and outdoors.
3,6/6kV 8,7/15kV
Part no. No.cores x Outer Permanent Tensile Cop. Weight Part no. No.cores x Outer Permanent Tensile Cop. Weight
cross-sec. min. - max. load strain weight app. cross-sec. min. - max. load strain weight app.
mm mm N max. N kg / km kg / km mm mm N max. N kg / km kg / km
38533 3 x 25 + 3 x 10 37,0 - 40,0 1500 2200 1008,0 2280,0 - 38545 3 x 25 + 3 x 10 43,0 - 46,0 1500 2200 1008,0 2750,0 -
38534 3 x 35 + 3 x 10 40,0 - 43,0 2000 3100 1292,0 2750,0 - 38546 3 x 35 + 3 x 10 46,0 - 48,0 2000 3100 1292,0 3210,0 -
38535 3 x 50 + 3 x 10 44,0 - 47,0 3000 4300 1728,0 3400,0 - 38547 3 x 50 + 3 x 10 49,0 - 52,0 3000 4300 1728,0 3950,0 -
38536 3 x 70 + 3 x 16 47,0 - 50,0 4100 5100 2477,0 4100,0 - 39040 3 x 70 + 3 x 16 53,0 - 57,0 4100 5100 2477,0 5000,0 -
38537 3 x 95 + 3 x 16 52,0 - 56,0 5600 7000 3197,0 5450,0 - 39041 3 x 95 + 3 x 16 58,0 - 62,0 5600 7000 3197,0 6150,0 -
38538 3 x 120 + 3 x 25 56,0 - 60,0 7100 8500 4176,0 6650,0 - 39042 3 x 120 + 3 x 25 63,0 - 67,0 7100 8500 4176,0 7700,0 -

6/10kV 12/20kV
Part no. No.cores x Outer Permanent Tensile Cop. Weight Part no. No.cores x Outer Permanent Tensile Cop. Weight
cross-sec. min. - max. load strain weight app. cross-sec. min. - max. load strain weight app.
mm mm N max. N kg / km kg / km mm mm N max. N kg / km kg / km
38539 3 x 25 + 3 x 10 39,0 - 42,0 1500 2200 1008,0 2400,0 - 39043 3 x 25 + 3 x 10 46,0 - 49,0 1500 2200 1008,0 3040,0 -
38540 3 x 35 + 3 x 10 42,0 - 45,0 2000 3100 1292,0 2900,0 - 39044 3 x 35 + 3 x 10 49,0 - 52,0 2000 3100 1292,0 3510,0 -
38541 3 x 50 + 3 x 10 45,0 - 48,0 3000 4300 1728,0 3450,0 - 39045 3 x 50 + 3 x 10 53,0 - 57,0 3000 4300 1728,0 4410,0 -
38542 3 x 70 + 3 x 16 50,0 - 54,0 4100 5100 2477,0 4600,0 - 39046 3 x 70 + 3 x 16 57,0 - 61,0 4100 5100 2477,0 5420,0 -
38543 3 x 95 + 3 x 16 54,0 - 58,0 5600 7000 3197,0 5770,0 - 39047 3 x 95 + 3 x 16 62,0 - 66,0 5600 7000 3197,0 6750,0 -
38544 3 x 120 + 3 x 25 58,0 - 62,0 7100 8500 4176,0 6900,0 - 39048 3 x 120 + 3 x 25 67,0 - 70,0 7100 8500 4176,0 8050,0 -

Dimensions and specifications may be changed without prior notice. (RQ03)

Suitable accessories can be found in Chapter X.


Tool - HAM 1

258
ROBOT CABLES

3
in

E
VD eld 29
ng

x
xe
ex

VD
ed
U

R/ shi E 0
xi
- fi
- fl

./
0 /

le

ed
i

no
H A ed / VD
-f

-f
U
C)

C)

ge

us

us

CS REG
e n es /
(

e
lta

di

di

se
re

re

t
fre

ut tan

r
n
ra

ra

co
tu

tu

u
vo

E
ai
n-

or
sis
ra

ra

A
d
ch
al

ge
in

in
pe

pe

re
do
re
in

ge
nd

nd

ag
lo

lo

re
V-
m

L/
om

Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
N
Robot cables

ROBOFLEX recycle -30 to +105 -40 to +105 300 7.5x 7.5x X X X X 262

ROBOFLEX 2001 / 2001-C -30 to +80 -40 to +80 300/500 7.5x 7.5x X X /X 264

ROBOFLEX 150,...151,...152,...153

-40 to +80 -40 to +80 300/500 15x 15x X X X /X X 265

ROBOFLEX sewer robot -40 to +80 -40 to +80 300/500 X X 267

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

261
Robot Cables

ROBOFLEX recycle

Technical data Cable structure Properties


Approval: Assembly (3-pin) very good resistance to oil as per
UL/cUL approved, UL-Style 20233 Bare copper litz wire DIN VDE 0473-811-404/DIN EN 60811-404
Production Core insulation TPE good resistance to acids, alkalis and solvents
in accordance with VDE standards Cores stranded in layers not cross-linked
Temperature range: -D-screen: screened version for robot weld splatter resistant
fixed installation -40C to +105C application recyclable
flexibel -30C to +105C -C-screen: in drag chain systems halogen-free
Nominal voltage: Sheath, special mix The materials used in manufacture are
300 V weld splatter resistant, dull, low adhesion cadmium-free and contain no silicone
Test voltage: Sheath colour: see below and free from substances harmful to
2000 V the wetting properties of lacquers
Minimum bending radius: Free of substances harmful to paint adhesion
7.5 x cable diameter (for flexible installation) substances
Traversing speed: very high mechanical load capacity
max. 3.3 m/s for 5 m of horizontal traverse abrasion resistant
path length wear-resistant
Acceleration: Highly flexible
max. 5 m/s UV-resistant
Flexing and torsion cycles:
min. 10 million.
Torsional stress:
+/- 360/m

Application
The cables with this new sheath material cover all requirements for very large mechanical stresses for abrasion, tear resistance, torsion, flexing, flexibility
and oil resistance. Using for automation technology, plant and machine construction, fixture construction for handling devices, welding devices and
welding tongs, assembly and handling devices, machining production, welding robots and tool machines, blast furnaces and rolling mills. The completely
new feature of this cable is the weld splatter resistance without the otherwise usual and required cross-linking process. Our newly developed
non-cross-linked thermoplastic elastomer is fully recyclable. In contrast to this, the usual, cross-linked, thermoplastic elastomers cannot be recycled
and put a not insignificant stress on our environment. This must be particularly interesting for customers who have an environment management
system according to DIN EN ISO 14001 and thus place a great deal of importance on the use of recyclable materials. A significantly longer service life
than that of existing cables on the market, because it can be used in highly flexible applications, for example on robots (torsion) and in drag chains
(dynamic load).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
ROBOFLEX recycle
Part no. Cable structure AWG-No.
Sheath colour No.cores x Core colours High Outer Cop. Weight
cross-sec. flex ** approx. mm weight approx.
mm kg / km kg / km
701889 BK RAL 9005 3 x 0,25 BN, BU, BK X 4,4 7,2 22,0 -
701891 YE RAL 1021 3 x 0,25 BN, BU, BK X 4,4 7,2 22,0 -
701890 GY RAL 7001 3 x 0,25 BN, BU, BK X 4,4 7,2 22,0 -
701894 YE RAL 1021 4 x 0,25 BN, BU, BK, WH X 4,7 9,6 26,0 -
701892 BK RAL 9005 4 x 0,25 BN, BU, BK, WH X 4,7 9,6 26,0 -
701893 GY RAL 7001 4 x 0,25 BN, BU, BK, WH X 4,7 9,6 26,0 -
701897 YE RAL 1021 5 x 0,25 BN, BU, BK, WH, GY X 4,8 12,0 30,0 -
701895 BK RAL 9005 5 x 0,25 BN, BU, BK, WH, GY X 4,8 12,0 30,0 -
701896 GY RAL 7001 5 x 0,25 BN, BU, BK, WH, GY X 4,8 12,0 30,0 -
702805 YE RAL 1021 8 x 0,25 DIN 47100 X 6,0 19,2 55,0 -
702803 BK RAL 9005 8 x 0,25 DIN 47100 X 6,0 19,2 55,0 -
702804 GY RAL 7001 8 x 0,25 DIN 47100 X 6,0 19,2 55,0 -
701900 YE RAL 1021 3 x 0,34 BN, BU, BK X 4,9 9,8 30,0 -
701898 BK RAL 9005 3 x 0,34 BN, BU, BK X 4,9 9,8 30,0 -
701899 GY RAL 7001 3 x 0,34 BN, BU, BK X 4,9 9,8 30,0 -

Continuation

262
Robot Cables

ROBOFLEX recycle
ROBOFLEX recycle
Part no. Cable structure AWG-No.
Sheath colour No.cores x Core colours High Outer Cop. Weight
cross-sec. flex ** approx. mm weight approx.
mm kg / km kg / km
701903 YE RAL 1021 4 x 0,34 BN, BU, BK, WH X 5,2 13,1 43,0 -
701901 BK RAL 9005 4 x 0,34 BN, BU, BK, WH X 5,2 13,1 43,0 -
701902 GY RAL 7001 4 x 0,34 BN, BU, BK, WH X 5,2 13,1 43,0 -
701906 YE RAL 1021 5 x 0,34 BN, BU, BK, WH, GY X 5,9 16,4 54,0 -
701904 BK RAL 9005 5 x 0,34 BN, BU, BK, WH, GY X 5,9 16,4 54,0 -
701905 GY RAL 7001 5 x 0,34 BN, BU, BK, WH, GY X 5,9 16,4 54,0 -
702808 YE RAL 1021 8 x 0,34 DIN 47100 X 6,8 26,1 78,0 -
702806 BK RAL 9005 8 x 0,34 DIN 47100 X 6,8 26,1 78,0 -
702807 GY RAL 7001 8 x 0,34 DIN 47100 X 6,8 26,1 78,0 -
701910 YE RAL 1021 5 G 0,5 BK with number, GN-YE X 6,0 24,0 65,0 -
701908 BK RAL 9005 5 G 0,5 BK with number, GN-YE X 6,0 24,0 65,0 -
701909 GY RAL 7001 5 G 0,5 BK with number, GN-YE X 6,0 24,0 65,0 -
701913 YE RAL 1021 5 G 0,75 BK with number, GN-YE X 7,0 36,0 80,0 -
701911 BK RAL 9005 5 G 0,75 BK with number, GN-YE X 7,0 36,0 80,0 -
701912 GY RAL 7001 5 G 0,75 BK with number, GN-YE X 7,0 36,0 80,0 -

ROBOFLEX recycle screened, D-screen


Part no. Cable structure AWG-No.
Sheath colour No.cores x Core colours High Outer Cop. Weight
cross-sec. flex ** approx. mm weight approx.
mm kg / km kg / km
703843 BK RAL 9005 3 x 0,25 BN, BU, BK X 5,0 17,0 44,6 -
703845 YE RAL 1021 3 x 0,25 BN, BU, BK X 5,0 17,0 44,6 -
703844 GY RAL 7001 3 x 0,25 BN, BU, BK X 5,0 17,0 44,6 -
703848 YE RAL 1021 4 x 0,25 BN, BU, BK, WH X 5,2 19,4 46,3 -
703846 BK RAL 9005 4 x 0,25 BN, BU, BK, WH X 5,2 19,4 46,3 -

H
703847 GY RAL 7001 4 x 0,25 BN, BU, BK, WH X 5,2 19,4 46,3 -
703851 YE RAL 1021 5 x 0,25 BN, BU, BK, WH, GY X 5,3 22,5 50,0 -
703849 BK RAL 9005 5 x 0,25 BN, BU, BK, WH, GY X 5,3 22,5 50,0 -
703850 GY RAL 7001 5 x 0,25 BN, BU, BK, WH, GY X 5,3 22,5 50,0 -
703869 YE RAL 1021 8 x 0,25 DIN 47100 X 6,8 34,1 53,5 -
703867 BK RAL 9005 8 x 0,25 DIN 47100 X 6,8 34,1 53,5 -
703868 GY RAL 7001 8 x 0,25 DIN 47100 X 6,8 34,1 53,5 -
703854 YE RAL 1021 3 x 0,34 BN, BU, BK X 5,2 19,6 48,2 -
703852 BK RAL 9005 3 x 0,34 BN, BU, BK X 5,2 19,6 48,2 -
703853 GY RAL 7001 3 x 0,34 BN, BU, BK X 5,2 19,6 48,2 -
703857 YE RAL 1021 4 x 0,34 BN, BU, BK, WH X 5,4 23,7 53,0 -
703855 BK RAL 9005 4 x 0,34 BN, BU, BK, WH X 5,4 23,7 53,0 -
703856 GY RAL 7001 4 x 0,34 BN, BU, BK, WH X 5,4 23,7 53,0 -
703860 YE RAL 1021 5 x 0,34 BN, BU, BK, WH, GY X 5,8 28,7 61,9 -
703858 BK RAL 9005 5 x 0,34 BN, BU, BK, WH, GY X 5,8 28,7 61,9 -
703859 GY RAL 7001 5 x 0,34 BN, BU, BK, WH, GY X 5,8 28,7 61,9 -
703872 YE RAL 1021 8 x 0,34 DIN 47100 X 7,3 58,0 85,0 -
703870 BK RAL 9005 8 x 0,34 DIN 47100 X 7,3 58,0 85,0 -
703871 GY RAL 7001 8 x 0,34 DIN 47100 X 7,3 58,0 85,0 -
703863 YE RAL 1021 5 G 0,5 BK with number, GN-YE X 7,0 52,0 76,0 -
703861 BK RAL 9005 5 G 0,5 BK with number, GN-YE X 7,0 52,0 76,0 -
703866 YE RAL 1021 5 G 0,75 BK with number, GN-YE X 7,6 70,0 93,0 -
703864 BK RAL 9005 5 G 0,75 BK with number, GN-YE X 7,6 70,0 93,0 -
703865 GY RAL 7001 5 G 0,75 BK with number, GN-YE X 7,6 70,0 93,0 -

ROBOFLEX recycle screened, C-screen


Part no. Cable structure AWG-No.
Sheath colour No.cores x Core colours High Outer Cop. Weight
cross-sec. flex ** approx. mm weight approx.
mm kg / km kg / km
703873 BK RAL 9005 3 x 0,25 BN, BU, BK X 5,0 17,0 44,6 -
703875 YE RAL 1021 3 x 0,25 BN, BU, BK X 5,0 17,0 44,6 -
703874 GY RAL 7001 3 x 0,25 BN, BU, BK X 5,0 17,0 44,6 -
703878 YE RAL 1021 4 x 0,25 BN, BU, BK, WH X 5,2 19,4 46,3 -
703876 BK RAL 9005 4 x 0,25 BN, BU, BK, WH X 5,2 19,4 46,3 -
703877 GY RAL 7001 4 x 0,25 BN, BU, BK, WH X 5,2 19,4 46,3 -
703881 YE RAL 1021 5 x 0,25 BN, BU, BK, WH, GY X 5,3 22,5 50,0 -
703879 BK RAL 9005 5 x 0,25 BN, BU, BK, WH, GY X 5,3 22,5 50,0 -
703880 GY RAL 7001 5 x 0,25 BN, BU, BK, WH, GY X 5,3 22,5 50,0 -
703899 YE RAL 1021 8 x 0,25 DIN 47100 X 6,8 34,1 53,5 -
703897 BK RAL 9005 8 x 0,25 DIN 47100 X 6,8 34,1 53,5 -
703898 GY RAL 7001 8 x 0,25 DIN 47100 X 6,8 34,1 53,5 -
703884 YE RAL 1021 3 x 0,34 BN, BU, BK X 5,2 19,6 48,2 -
703882 BK RAL 9005 3 x 0,34 BN, BU, BK X 5,2 19,6 48,2 -
703883 GY RAL 7001 3 x 0,34 BN, BU, BK X 5,2 19,6 48,2 -
703887 YE RAL 1021 4 x 0,34 BN, BU, BK, WH X 5,4 23,7 53,0 -
703885 BK RAL 9005 4 x 0,34 BN, BU, BK, WH X 5,4 23,7 53,0 -
703886 GY RAL 7001 4 x 0,34 BN, BU, BK, WH X 5,4 23,7 53,0 -
703890 YE RAL 1021 5 x 0,34 BN, BU, BK, WH, GY X 5,8 28,7 61,9 -
703888 BK RAL 9005 5 x 0,34 BN, BU, BK, WH, GY X 5,8 28,7 61,9 -
703889 GY RAL 7001 5 x 0,34 BN, BU, BK, WH, GY X 5,8 28,7 61,9 -
703902 YE RAL 1021 8 x 0,34 DIN 47100 X 7,3 58,0 85,0 -
703900 BK RAL 9005 8 x 0,34 DIN 47100 X 7,3 58,0 85,0 -
703901 GY RAL 7001 8 x 0,34 DIN 47100 X 7,3 58,0 85,0 -
703893 YE RAL 1021 5 G 0,5 BK with number, GN-YE X 7,0 52,0 76,0 -
703891 BK RAL 9005 5 G 0,5 BK with number, GN-YE X 7,0 52,0 76,0 -
703892 GY RAL 7001 5 G 0,5 BK with number, GN-YE X 7,0 52,0 76,0 -
703896 YE RAL 1021 5 G 0,75 BK with number, GN-YE X 7,6 70,0 93,0 -
703894 BK RAL 9005 5 G 0,75 BK with number, GN-YE X 7,6 70,0 93,0 -
703895 GY RAL 7001 5 G 0,75 BK with number, GN-YE X 7,6 70,0 93,0 -

Dimensions and specifications may be changed without prior notice.

263
Robot Cables

ROBOFLEX 2001 / 2001-C Robot cables, meter marking

Technical data Cable structure Properties


Special TPE-E/PUR adapted to Bare copper, stranded to DIN VDE 0295 High flexibility at low temperatures
DIN VDE 0250 / DIN VDE 0285-525-1 / and IEC 60228, fine or extra fine wires, High abrasion resistance
DIN EN 50525-1 cl.5 or cl.6, BS 6360 cl.5 or 6, up to Loadable under torsion stress 360/meter
Temperature range 0,34 mm cl.5, above 0,5 mm cl.6 Low adhesion
flexing -30C to +80C Special core insulation, PP Resistant to
fixed installation -40C to +80C Cores coded Microbes and rotting
Nominal voltage up to 0,34 mm according DIN 47100 Oxygene and ozone
up to 0,34 mm 350 V (operating peak above 0,5 mm black cores with Vibrations
voltage) continuous white numbering acc. to UV-radiation
from 0,5 mm U0/U 300/500 V DIN VDE 0293 Largely resistant to
Test voltage GN-YE conductor, 3 cores and above Oil and fats resistant
up to 0,34 mm 1,5 kV, 5 minutes in the outer layer AWG sizes are approximate equivalent
from 0,5 mm 3,0 kV, 5 minutes Cores stranded in layers with values. The actual cross-section is in mm
Mutual capacitance optimal lay-length
core/core approx. 100 nF/km Special separating foil
core/screen approx. 120 nF/km Cable structure C-type, cu-screen of helically
Inductance approx. wound, approx. 85-95% coverage
0,69 mH/km Outher sheath, special polyurethane
Minimum bending radius Sheath colour black (RAL 9005)
7,5x cabel with meter marking

Application
These special robotic control and signal cables specially designed for torsion and bending stresses in robots and connecting handling tools.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
ROBOFLEX 2001 ROBOFLEX 2001-C
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25459 7 x 0,25 5,8 16,8 48,0 24 25539 10 x 0,14 7,8 34,2 62,0 26
25439 12 x 0,25 7,6 28,8 71,0 24 25488 12 x 0,14 7,8 42,1 95,0 26
25460 25 x 0,25 10,6 60,0 143,0 24 25489 18 x 0,14 9,7 54,5 120,0 26
25461 2 x 0,34 4,0 6,6 28,0 22 25490 25 x 0,14 10,9 69,0 158,0 26
25462 3 x 0,34 4,0 9,8 34,0 22 25491 12 x 0,25 8,3 59,5 126,0 24
25440 7 x 0,34 5,7 22,8 51,0 22 25492 18 x 0,25 10,1 80,0 164,0 24
25449 12 x 0,34 8,3 39,2 69,0 22 25493 25 x 0,25 11,1 103,0 215,0 24
25463 12 G 0,5 10,4 57,8 90,0 20 25494 12 x 0,34 8,8 78,0 160,0 22
25519 16 G 0,5 11,6 76,8 277,0 20 25495 18 x 0,34 10,8 101,0 210,0 22
25464 18 G 0,5 12,7 86,4 121,0 20 25496 25 x 0,34 12,0 158,0 305,0 22
25465 25 G 0,5 14,2 120,0 256,0 20 25497 12 G 0,5 11,2 117,0 175,0 20
25466 4 G 0,75 6,0 28,8 63,0 19 25498 18 G 0,5 13,6 160,0 231,0 20
25450 7 G 0,75 7,9 50,4 96,0 19 25499 25 G 0,5 14,8 255,0 347,0 20
25467 12 G 0,75 11,5 84,4 171,0 19 25500 12 G 0,75 11,8 155,0 220,0 19
25468 14 G 0,75 12,8 100,8 200,0 19 25501 18 G 0,75 15,0 210,0 305,0 19
25469 2x1 5,5 19,2 48,0 18 25502 25 G 0,75 16,6 275,0 415,0 19
25470 3G1 6,0 29,0 60,0 18 705462 3G1 6,3 76,0 90,0 18
25471 4G1 6,3 38,4 78,0 18 25503 12 G 1 13,0 190,0 265,0 18
25472 7G1 8,5 67,2 131,0 18 25504 18 G 1 16,1 245,0 390,0 18
25473 12 G 1 12,5 115,2 216,0 18 25505 25 G 1 18,1 345,0 540,0 18
25474 18 G 1 15,4 172,8 306,0 18 25506 12 G 1,5 16,2 260,0 345,0 16
25475 25 G 1 17,4 240,0 432,0 18 25507 18 G 1,5 20,3 370,0 485,0 16
25476 34 G 1 21,3 326,4 569,0 18 25508 25 G 1,5 22,5 498,0 710,0 16
25477 41 G 1 23,2 393,6 694,0 18
25520 3 G 1,5 6,9 43,2 94,0 16
25529 4 G 1,5 7,9 57,6 107,0 16
25559 5 G 1,5 8,6 72,0 121,0 18
25509 8 G 1,5 11,1 115,2 292,0 16
25478 12 G 1,5 15,5 172,8 356,0 16
25479 18 G 1,5 19,3 259,2 445,0 16
25480 25 G 1,5 21,8 360,0 636,0 16
25481 3 G 2,5 8,4 72,0 136,0 14
25482 4 G 2,5 9,1 96,0 170,0 14
25483 3G4 10,3 116,0 227,0 12
25530 4G4 11,2 153,6 261,0 12
25510 4G6 14,1 230,4 341,0 10
25484 3 G 10 15,6 288,0 518,0 8
25485 3 G 16 18,2 460,8 722,0 6
25486 3 G 25 22,9 720,0 1180,0 4
25487 3 G 35 26,5 1008,0 1600,0 2

Dimensions and specifications may be changed without prior notice. (RH01)

264
Robot Cables

ROBOFLEX 150,...151,...152,...153 PUR, halogen-free,


for torsional stress, meter marking

Technical data Cable structure Properties


Special TPE-E/PUR robot cable Bare copper, stranded to DIN VDE 0295 and PUR outer sheath, low adhesion, abrasion
based on DIN VDE 0250 / IEC 60228, fine or extra fine wires, resistant, halogen-free, resistant to UV, oil,
DIN VDE 0285-525-1 / DIN EN 50525-1 cl.5 or cl.6, BS 6360 cl.5 or 6, hydrolysis and microbial attack
Temperature range up to 0,34 mm cl.5, above 0,5 mm cl.6 The smooth, high-grade core insulation,
flexing -40C to +80C TPE-E core insulation together with special stranding configuration
Nominal voltage Black cores continuous white numbering and slide wrapping ensure long service life
up to 0,34 mm 350 V acc. to DIN VDE 0293 + gnye under combined bending and torsional
from 0.5 mm U0/U 300/500 V Special optimised stranding stresses
Test voltage High-grade slide wrapping AWG sizes are approximate equivalent
up to 0,34 mm 1500 V
from 0.5 mm 3000 V
with meter marking
Tinned copper twist screen
values. The actual cross-section is in mm H
Insulation resistance PUR outer sheath
min. 20 MOhm x km Sheath colour: grey (RAL 7001) or black
Max. torsion angle Part. nos. 77261-77263, 76158, 70561,
360/metre 77267, 77268, 76165, 76166, 77424
Mutual capacitance Core colours DIN 47100
core/core approx. 100 nF/km Part no. 71820, 74658, 77264, 75253,
core/screen approx. 120 nF/km 76167
Minimum bending radius Construction as above, but 0,5 (1,5) mm
15x cable cores screened with aluminium-coated
polyester foil
Part no. 72214
Construction as above, but 0,5 mm pair
screened with tinned twist screen
Part no. 77265, 77266, 77269, 77270
Construction as above, but 1,0 mm pair
only, screened with tinned twist screen
Part no. 77469
Construction as above, but
6 cores, 1,5 mm, screened with tinned
twist screen
4 pairs, 0,25 mm, screened with tinned
twist screen
Sheath colour: orange (RAL 2003)
with meter marking

Application
These cables are specially designed for combined torsional and bending stresses. They are employed both for power supply and for the transmission
of control and monitoring signals. ROBOFLEX cables are used in assembly and welding robots, in handling and automation centres, in transport and
conveyor equipment, and on turntables and swivel tables. In other words, anywhere where there is no defined cable routing with only alternating
bending cycles on a single plane such as in drag chains.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Continuation

265
Robot Cables

ROBOFLEX 150,...151,...152,...153 PUR, halogen-free,


for torsional stress, meter marking
ROBOFLEX 150 (screened), Sheath colour grey ROBOFLEX 152 (screened), Sheath colour black
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
77261 ( 12 x 0,25) 8,3 59,5 126,0 24 76161 ( 4 x 1,5) 8,9 81,7 150,0 16
77266 23 x 1 + (2 x 1,0) 17,4 262,0 473,0 - 76162 ( 4 x 2,5) 11,2 164,0 280,0 14
71789 ( 4 x 1,5) 8,9 81,7 150,0 16 76163 ( 4 x 4) 13,1 222,0 400,0 12
75251 ( 4 x 2,5) 11,2 134,0 280,0 14 76164 ( 4 x 6) 15,4 305,0 550,0 10
75252 ( 4 x 4) 13,1 200,0 400,0 12 77267 ( 3 x 2 x 0,14) 5,8 23,0 43,0 26
76157 ( 4 x 6) 15,4 286,0 550,0 10 77268 ( 4 x 2 x 0,14) 6,9 26,6 55,0 26
77262 ( 3 x 2 x 0,14) 5,8 17,0 43,0 26 77424 ( 3 x 2 x 0,25) 7,3 32,0 65,0 24
77263 ( 4 x 2 x 0,14) 6,9 37,0 75,0 26 76165 ( 5 x 2 x 0,34) 9,2 65,0 116,0 22
76158 ( 5 x 2 x 0,34) 9,2 65,0 116,0 22 76166 ( 8 x 2 x 0,34) 10,2 90,0 150,0 22
70561 ( 8 x 2 x 0,34) 10,2 90,0 150,0 22 75415 ( 4 x 1,5 + (2 x 0,5)) 10,7 95,0 170,0 16
71820 ( 4 x 1,5 + (2 x 0,62)) 10,5 106,8 195,0 16 75416 ( 4 x 2,5 + (2 x 0,5)) 11,8 115,0 220,0 14
74658 ( 4 x 1,5 + (2 x 0,5)) 10,7 95,0 180,0 16 75940 ( 4 x 2,5 + (2 x 1,0)) 12,3 147,0 250,0 14
77264 ( 4 x 1,5 + (2 x 1,0)) 11,1 128,0 220,0 16 75167 ( 4 x 4 + (2 x 0,5)) 13,5 260,0 340,0 12
75253 ( 4 x 2,5 + (2 x 0,5)) 12,5 180,0 270,0 14 75417 ( 4 x 4 + (2 x 1,0)) 14,0 237,0 350,0 12
72214 ( 4 x 4 + (2 x 0,62)) 13,5 260,0 340,0 12 75418 ( 4 x 6 + (2 x 1,0)) 16,0 316,0 500,0 10
76159 ( 4 x 4 + (2 x 1,0)) 14,0 237,0 350,0 12 77269 16 x 1 + (2 x 1,0) 16,7 176,0 380,0 18
76160 ( 4 x 6 + (2 x 1,0)) 16,0 341,0 500,0 10 77270 23 x 1 + (2 x 1,0) 17,4 262,0 473,0 18
77265 16 x 1 + (2 x 1,0) 16,7 197,0 380,0 18 77469 5 x 2,5 + (6 x 1,5) + 4 x (2 x 16,7 320,0 460,0 14
0,25)

ROBOFLEX 151, Sheath colour grey ROBOFLEX 153, Sheath colour black
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
70116 12 G 0,5 8,3 57,6 131,0 20 76172 4 G 1,5 8,5 57,6 106,0 16
76168 4 G 1,5 8,5 57,6 106,0 16 76174 4G4 12,7 153,6 283,0 12
76169 4 G 2,5 10,8 96,0 196,0 14 76175 4G6 15,0 230,4 432,0 10
76170 4G4 12,7 153,6 283,0 12
76171 4G6 15,0 230,4 432,0 10

Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Heat shrink tubing - SPSP coils

266
Robot Cables

ROBOFLEX sewer robot trailing

Technical data Cable structure Properties


Temperature range Part No. 74540 To enhance reliability and tensile strength, a
flexing -40C to +80C Bare copper, ultra-fine wire conductors high-tensile and high-torsion resistant Kevlar
Nominal voltage acc. to DIN VDE 0295 cl.6 and/or braid is incorporated into the extremely robust
300/500 V IEC 60228 cl.6 PUR sheath
Test voltage 3000 V Core insulation TPE-E, black with numbering Part No. 74540+76397
Insulation resistance 3 COAX 187/U stranded PUR sheath: low adhesion, extremely abrasion
min. 20 MOhm x km Cores and COAX elements and PVC sleeves, resistant, halogen-free, resistant to UV, oil,
special stranded hydrolysis and microbial attack
PUR outer sheath with embedded high-tensile Part No. 70581
and high-torsion resistant Kevlar braid Special PVC sheath, largely oil resistant,
Sheath colour orange (RAL 2003)
Part No. 70581
self-extinguishing and flame retardant
acc. to DIN VDE 0482-332-1-2,
H
Bare copper, ultra-fine wire conductors acc. DIN EN 60332-1-2, IEC 60332-1 (equivalent
to DIN VDE 0295 cl.6 or IEC 60228 cl.6 DIN VDE 0472 part 804 test method B)
PVC core insulation, colour code DIN 47100 chemical resistant,
Cores stranded with COAX (see table Technical Information)
Overall screening with tinned copper braid,
coverage approx. 85%
Special PVC sheath
Sheath colour grey (RAL 7001)
Part No. 76397 (trailing cable for video
cameras)
Tinned copper conductor, fine wire stranded
Core insulation of cell polypropylene
Screen of aluminium-coated polyester foil and
tinned copper braiding
PUR outer sheath
Sheath colour blue (RAL 5015)

Application
These cables are designed for use with autonomous sewer robots. These robots are used to inspect municipal sewer networks and if necessary to
locate leaks or blockages. Some of these robots are even able to seal such leaks after detecting them. Besides cores for power supply, they also contain
data cables, hoses for various drives, and coaxial cables for the video camera mounted on the robot.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Dimensions and specifications may be changed without prior notice. (RH01)

Suitable accessories can be found in Chapter X.


Heat shrink tubing - SPSP coils

267
WATER-RESISTANT CABLES

3
in

E
VD eld 29
ng

x
xe
ex

VD
ed
U

R/ shi E 0
xi
- fi
- fl

./
0 /

le

ed
i

no
H A ed / VD
-f

-f
U
C)

C)

ge

us

us

CS REG
e n es /
(

e
lta

di

di

se
re

re

t
fre

ut tan

r
n
ra

ra

co
tu

tu

u
vo

E
ai
n-

or
sis
ra

ra

A
d
ch
al

ge
in

in
pe

pe

re
do
re
in

ge
nd

nd

ag
lo

lo

re
V-
m

L/
om

Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
N
Water-resistant cables

Tauchflex-R -25 to +80 -40 to +80 450/750 5x 4x X X 270

Tauchflex-FL -25 to +80 -40 to +80 450/750 5x 4x X X 271

H07 RN8-F -25 to +40 -40 to +40 450/750 6x 4x X X X 272

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

269
Water resistant Cables

Tauchflex-R 750 V, blue, submersible-pump cable

Technical data Cable structure Properties


Special cables corresponding apapted to Bare copper-conductor, to Good insulation properties when submerged
DIN VDE 0250/DIN VDE 0285-525-2-21/ DIN VDE 0295 cl.5, fine-wire, in water
DIN EN 50525-2-21 BS 6360 cl.5, IEC 60228 cl.5 Minimal weight gain under water
Temperature range (max. temperature Core insulation to EPR The mechanical stability of the insulation
for the outer surface) -40C to +80C Core identification to DIN VDE 0293 materials remains constant even when
Temperature limit in water: GN-YE conductor, 3 cores and above submerged
max. +40C, max. +60C Cores standed in layers with As rotor-connection cable for motors up to
with limited duration of life optimal lay-length 1000 V with protected fixed installation in
Temperature limit in air: Outer sheath of special EPR tubes.
flexible -25C to +80C Sheath colour blue
fixed installation -40C to +80C Note
Permissible operating temperature G = with green-yellow conductor
at conductor +90C x = without green-yellow conductor
Nominal voltage U0/U 450/750 V AWG sizes are approximate equivalent
Operating voltage values. The actual cross-section is in mm.
at alternating and three-phase currents
U0/U 413/825 V
at direct currents U0/U 619/1238 V
Test voltage 2,5 kV, 15 min
Max. permitted tensile stress
per mm conductor 15 N
Minimum bending radius
flexing
up to 8 mm cable : 3x cable
> 8-12 mm cable : 4x cable
> 12 mm cable : 5x cable
fixed installation
up to 12 mm cable : 3x cable
> 12 mm cable : 4x cable

Application
Tauchflex-R is a special cable for use as a connecting and control cable for submersible motor pumps, underwater floodlights, floating switch and has
proven its worth for constant use in drinking water, process water and service water up to an immersion depth of 300 m.
Tauchflex-R can also be installed for use in dry, damp and humid areas as well as in the open air. Not suitable for the installation in hazardous areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
37100 1 x 1,5 6,0 14,0 54,0 16 37127 3 G 10 19,0 288,0 750,0 8
37101 1 x 2,5 6,7 24,0 76,0 14 37128 3 G 16 23,5 461,0 1110,0 6
37102 1x4 7,2 38,0 105,0 12 37129 3 G 25 28,5 720,0 1450,0 4
37103 1x6 7,9 58,0 135,0 10 37130 3 G 35 32,0 1008,0 2150,0 2
37104 1 x 10 9,5 96,0 200,0 8 37131 3 G 50 37,0 1440,0 2800,0 1
37105 1 x 16 11,5 154,0 290,0 6 37132 3 G 70 42,0 2016,0 3750,0 2/0
37106 1 x 25 13,5 240,0 400,0 4 37133 3 G 95 43,3 2736,0 4590,0 3/0
37107 1 x 35 15,0 336,0 560,0 2 37134 3 G 120 49,0 3456,0 5400,0 4/0
37108 1 x 50 17,5 480,0 730,0 1 37135 4 G 1,5 10,7 58,0 190,0 16
37109 1 x 70 20,0 672,0 1000,0 2/0 37136 4 G 2,5 12,3 96,0 270,0 14
37110 1 x 95 22,5 912,0 1250,0 3/0 37137 4G4 14,0 154,0 380,0 12
37111 1 x 120 24,0 1152,0 1650,0 4/0 37138 4G6 15,5 230,0 520,0 10
37112 1 x 150 25,2 1440,0 2000,0 300 kcmil 37139 4 G 10 21,0 384,0 955,0 8
37113 1 x 185 27,6 1776,0 2460,0 350 kcmil 37140 4 G 16 25,5 614,0 1400,0 6
37114 1 x 240 30,6 2304,0 3050,0 500 kcmil 37141 4 G 25 31,0 960,0 1950,0 4
37115 1 x 300 33,5 2880,0 3700,0 600 kcmil 37142 4 G 35 35,0 1344,0 2650,0 2
37116 2 x 1,5 8,5 29,0 130,0 16 37143 4 G 50 41,0 1920,0 3600,0 1
37117 2 x 2,5 10,2 48,0 190,0 14 37144 4 G 70 46,5 2688,0 4890,0 2/0
37118 2x4 11,8 77,0 260,0 12 37145 4 G 95 51,6 3648,0 6180,0 3/0
37119 2x6 13,1 115,0 350,0 10 37146 4 G 120 56,1 4608,0 7200,0 4/0
37120 2 x 10 17,7 192,0 550,0 8 37147 5 G 1,5 11,2 72,0 225,0 16
37121 2 x 16 20,2 307,0 900,0 6 37148 5 G 2,5 13,3 120,0 335,0 14
37122 2 x 25 24,3 480,0 1300,0 4 37149 5G4 15,6 192,0 470,0 12
37123 3 G 1,5 9,5 43,0 150,0 16 37150 5G6 17,5 288,0 645,0 10
37124 3 G 2,5 11,0 72,0 205,0 14 37151 5 G 10 22,9 480,0 1150,0 8
37125 3G4 13,0 115,0 330,0 12 37152 5 G 16 26,4 768,0 1690,0 6
37126 3G6 14,5 173,0 470,0 10 37153 5 G 25 32,0 1200,0 2400,0 4

Dimensions and specifications may be changed without prior notice. (RI01)

270
Water resistant Cables

Tauchflex-FL 750 V, blue, submersible pump cable

Technical data Cable structure Properties


Special cables corresponding adapted to Bare copper-conductor, to Good insulation properties when submerged
DIN VDE 0250/DIN VDE 0285-525-2-21/ DIN VDE 0295 cl.5, fine-wire, in water
DIN EN 50525-2-21 BS 6360 cl.5, IEC 60228 cl.5 Minimal weight gain under water
Temperature range (max. temperature Core insulation of EPR The mechanical stability of the insulation
for the outer surface)-40C to +80C Core identification to DIN VDE 0293 materials remains constant even when
Temperature limit in water: GN-YE conductor, 3 cores and above submerged
max. +40C, max. +60C Cores laying parallel As rotor-connection cable for motors up to
with limited duration of life Outer sheath of special ERP 1000 V with protected fixed installation in
Temperature limit in air: Sheath colour blue tubes.
flexible -25C to +80C
fixed installation -40C to +80C Note
Permissible operating temperature G = with green-yellow conductor
at conductor +90C x = without green-yellow conductor
Nominal voltage U0/U 450/750 V
Operating voltage
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
I
atalternating and three-phase currents
U0/U 413/825 V
at direct currents U0/U 619/1238 V
Test voltage 2,5 kV, 15 min.
Max. permitted tensile stress
per mm conductor 15 N
Minimum bending radius
flexing 5x cable thickness
fixed installation 4x cable thickness

Application
Tauchflex-FL is a special cable for use as a connecting and control cable for submersible motor pumps, underwater floodlights, floating switch and
has proven its worth for constant use in drinking water, process water and service water up to an immersion depth of 300 m.
Tauchflex-FL can also be installed for use in dry, damp and humid areas as well as in the open air. Not suitable for the installation in hazardous areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight approx. cross-sec. dimension weight approx.
mm approx. mm kg / km kg / km mm approx. mm kg / km kg / km
37155 3 x 1,5 7,0 x 13,0 43,0 125,0 16 37167 4 G 1,5 7,0 x 17,0 58,0 160,0 16
37156 3 x 2,5 8,0 x 16,0 72,0 185,0 14 37168 4 G 2,5 8,0 x 20,0 96,0 245,0 14
37157 3x4 9,0 x 19,0 115,0 290,0 12 37169 4G4 9,0 x 24,0 154,0 330,0 12
37158 3x6 10,0 x 23,0 173,0 400,0 10 37170 4G6 10,0 x 26,0 230,0 450,0 10
37159 3 x 10 12,0 x 28,0 288,0 615,0 8 37171 4 G 10 11,0 x 31,0 384,0 850,0 8
37160 3 x 16 14,0 x 31,0 461,0 890,0 6 37172 4 G 16 13,0 x 36,0 614,0 1200,0 6
37161 3 x 25 17,0 x 37,0 720,0 1155,0 4 37173 4 G 25 15,0 x 45,0 960,0 1590,0 4
37162 3 x 35 17,0 x 38,0 1008,0 1540,0 2 37174 4 G 35 17,0 x 48,0 1344,0 2085,0 2
37163 3 x 50 20,0 x 45,0 1440,0 2190,0 1 37175 4 G 50 20,0 x 59,0 1920,0 2890,0 1
37164 3 x 70 22,0 x 52,0 2016,0 2890,0 2/0
37165 3 x 95 25,0 x 58,0 2736,0 3800,0 3/0
37166 3 x 120 27,0 x 64,0 3456,0 4700,0 4/0

Dimensions and specifications may be changed without prior notice. (RI01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS Plus

271
Water resistant Cables

H07RN8-F waterproof rubber-sheathed cable, harmonized type

Technical data Cable structure Properties


Water resistant heavy hose pipe Bare copper-conductor, to Resistant to
to DIN VDE 0285-525-2-21 / DIN VDE 0295 cl.5, fine-wire, Ozone
DIN EN 50525-2-21 BS 6360 cl.5, IEC 60228 cl.5 Weather
Temperature range Core insulation of rubber The core identification of a single core
flexing -25C compound type EI4 to sheathed, of an insulated wire is black.
fixed installation -40C DIN VDE 0207-363-1 / DIN EN 50363-1 Tests
in water max. +40C Core identification to DIN VDE 0293-308 Oil resistant acc. to DIN VDE 0473-811-404/
Permissible operating temperature - up to 5 cores coloured DIN EN 60811-404
at conductor +60C - from 6 cores, black with continuous Behaviour in fire
Nominal voltage U0/U 450/750 V white numbering to DIN VDE 0482-332-1-2
in case of protected and fixed installation GN-YE conductor, 3 cores and above DIN EN 60332-2-1, IEC 60332-1 (equivalent
U0/U 600/1000 V Cores stranded in layers with DIN VDE 0472 part 804 test method B)
Test voltage 2500 V optimal lay-length
Permanent tensile load Outer sheath of special polychoroprene Note
max. 15 N/mm rubber G = with green-yellow conductor
Minimum bending radius Outer sheath black x = without green-yellow conductor
flexing 6x cable AWG sizes are approximate equivalent
fixed installation 4x cable values. The actual cross-section is in mm.

Application
Specifically designed for use in fresh water up to 10 m water depth and a maximum water temperature of 40C for connection of submersible pumps
and similar applications. Not suitable for underwater power transmission systems or in waterways or in areas where mechanical damage is possible
which represent a potential danger.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
37287 1 x 1,5 5,7 - 7,1 14,4 58,0 16 37323 3 G 70 38,4 - 48,3 2016,0 3400,0 2/0
37288 1 x 2,5 6,3 - 7,9 24,0 71,0 14 37324 3 G 95 43,3 - 54,0 2736,0 4450,0 3/0
37289 1x4 7,2 - 9,0 38,0 100,0 12 37325 3 G 120 47,4 - 60,0 3456,0 5180,0 4/0
37290 1x6 7,9 - 9,8 58,0 130,0 10 37326 3 G 150 52,0 - 66,0 4320,0 6500,0 300 kcmil
37291 1 x 10 9,5 - 11,9 96,0 230,0 8 37327 3 G 185 57,0 - 72,0 5328,0 7860,0 350 kcmil
37292 1 x 16 10,8 - 13,4 154,0 290,0 6 37328 3 G 240 65,0 - 82,0 6192,0 10224,0 500 kcmil
37293 1 x 25 12,7 - 15,8 240,0 420,0 4 37329 3 G 300 72,0 - 90,0 8640,0 12620,0 600 kcmil
37294 1 x 35 14,3 - 17,9 336,0 530,0 2 37330 4G1 9,2 - 11,9 38,0 150,0 18
37295 1 x 50 16,5 - 20,6 480,0 750,0 1 37331 4 G 1,5 10,2 - 13,1 58,0 200,0 16
37296 1 x 70 18,6 - 23,3 672,0 960,0 2/0 37332 4 G 2,5 12,1 - 15,5 96,0 290,0 14
37297 1 x 95 20,8 - 26,0 912,0 1250,0 3/0 37333 4G4 14,0 - 17,9 154,0 395,0 12
37298 1 x 120 22,8 - 28,6 1152,0 1560,0 4/0 37334 4G6 15,7 - 20,0 230,0 540,0 10
37299 1 x 150 25,2 - 31,4 1440,0 1900,0 300 kcmil 37335 4 G 10 20,9 - 26,5 384,0 950,0 8
37300 1 x 185 27,6 - 34,4 1776,0 2300,0 350 kcmil 37336 4 G 16 23,8 - 30,1 614,0 1260,0 6
37301 1 x 240 30,6 - 38,3 2304,0 2950,0 500 kcmil 37337 4 G 25 28,9 - 36,6 960,0 1860,0 4
37302 1 x 300 33,5 - 41,9 2880,0 3600,0 600 kcmil 37338 4 G 35 32,5 - 41,1 1344,0 2380,0 2
37303 1 x 400 37,4 - 46,8 3840,0 4600,0 750 kcmil 37339 4 G 50 37,7 - 47,5 1920,0 3190,0 1
37304 1 x 500 41,3 - 52,0 4800,0 6000,0 1000 kcmil 37340 4 G 70 42,7 - 54,0 2688,0 4260,0 2/0
37305 2x1 7,7 - 10,0 19,0 98,0 18 37341 4 G 95 48,4 - 61,0 3648,0 5600,0 3/0
37306 2 x 1,5 8,5 - 11,0 29,0 135,0 16 37342 4 G 120 53,0 - 66,0 4608,0 6830,0 4/0
37307 2 x 2,5 10,2 - 13,1 48,0 193,0 14 37343 4 G 150 58,0 - 73,0 5760,0 8320,0 300 kcmil
37308 2x4 11,8 - 15,1 77,0 280,0 12 37344 4 G 185 64,0 - 80,0 7104,0 9800,0 350 kcmil
37309 2x6 13,1 - 16,8 115,0 330,0 10 37345 4 G 240 72,0 - 91,0 9216,0 12100,0 500 kcmil
37310 2 x 10 17,7 - 22,6 192,0 586,0 8 37346 4 G 300 80,0 - 101,0 11520,0 15200,0 600 kcmil
37311 2 x 16 20,2 - 25,7 307,0 810,0 6 37354 5G1 10,2 - 13,1 48,0 175,0 18
37312 2 x 25 24,3 - 30,7 480,0 1160,0 4 37347 5 G 1,5 11,2 - 14,4 72,0 240,0 16
37313 3G1 8,3 - 10,7 29,0 130,0 18 37348 5 G 2,5 13,3 - 17,0 120,0 345,0 14
37314 3 G 1,5 9,2 - 11,9 43,0 165,0 16 37349 5G4 15,6 - 19,9 192,0 485,0 12
37315 3 G 2,5 10,9 - 14,0 72,0 235,0 14 37350 5G6 17,5 - 22,2 288,0 650,0 10
37316 3G4 12,7 - 16,2 115,0 320,0 12 37351 5 G 10 22,9 - 29,1 480,0 1200,0 8
37317 3G6 14,1 - 18,0 173,0 420,0 10 37352 5 G 16 26,4 - 33,3 768,0 1550,0 6
37318 3 G 10 19,1 - 24,2 288,0 810,0 8 37353 5 G 25 32,0 - 40,4 1200,0 2250,0 4
37319 3 G 16 21,8 - 27,6 461,0 1050,0 6 37355 6 G 1,5 13,4 - 17,2 87,0 171,0 16
37320 3 G 25 26,1 - 33,0 720,0 1250,0 4 37356 6 G 2,5 15,7 - 20,0 144,0 279,0 14
37321 3 G 35 29,3 - 37,1 1008,0 1900,0 2 37357 12 G 1,5 17,6 - 22,4 173,0 340,0 16
37322 3 G 50 34,1 - 42,9 1440,0 2600,0 1 37358 12 G 2,5 20,6 - 26,2 288,0 571,0 14

Dimensions and specifications may be changed without prior notice. (RI01)

272
FLAT & RIBBON CABLES

3
in

E
VD eld 29
ng

x
xe
ex

VD
ed
U

R/ shi E 0
xi
- fi
- fl

./
0 /

le

ed
i

no
H A ed / VD
-f

-f
U
C)

C)

ge

us

us

CS REG
e n es /
(

e
lta

di

di

se
re

re

t
fre

ut tan

r
n
ra

ra

co
tu

tu

u
vo

E
ai
n-

or
sis
ra

ra

A
d
ch
al

ge
in

in
pe

pe

re
do
re
in

ge
nd

nd

ag
lo

lo

re
V-
m

L/
om

Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
N
Flat & ribbon cables

PVC-flat -5 to +70 -40 to +80 300/500 10x 10x X 276

NEO-flat -30 to +80 -40 to +80 300/500 10x 10x X X 277

PVC-flat-CY -5 to +70 -40 to +80 300/500 15x 15x X X 278

NEO-flat-C -30 to +80 -40 to +80 300/500 15x 15x X X X 279

Ribbon -5 to +70 -5 to +70 350/600 X 280

TUBEFLEX-Y -20 to +80 -20 to +80 300 15x 15x 281

TUBEFLEX-(St)-CY -20 to +80 -20 to +80 300 15x 15x X 282

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

275
Flat and Ribbon Cables

PVC-flat 300/500 V and 450/750 V

Technical data Cable structure Properties


Special PVC-flat cable adapted to Bare copper-conductor, to Extensively oil resistant, oil-/ chemical
EN 50214 / DIN VDE 0283-2 DIN VDE 0295 cl.5, fine-wire, Resistance - see table Technical
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Informations
flexing -5C to +70C Core insulation of PVC Extremely small bending radius
fixed installation -40C to +80C compound type TI2 to High flexibility
Nominal voltage DIN VDE 0207-363-3 / DIN EN 50363-3 Minimum waste of space
up to 1 mm U0/U 300/500 V Core identification to DIN VDE 0293 Packeting possibility
from 1,5 mm U0/U 450/750 V - up to 5 cores coloured The materials used in manufacture are
Test voltage - from 7 cores, black with continuous cadmium-free and contain no silicone
up to 1 mm 2000 V white numbering and free from substances harmful to
from 1,5 mm 2500 V Cores laying parallel the wetting properties of lacquers
Minimum bending radius GN-YE conductor Tests
10x cable thickness Outer sheath of special PVC PVC self-extinguishing and flame retardant
Radiation resistance compound type TM2 to acc. to DIN VDE 0482-332-1-2,
up to 80x106 cJ/kg (up to 80 Mrad) DIN VDE 0207-363-4-1/DIN EN 50363-4-1 DIN EN 60332-1-2, IEC 60332-1 (equivalent
Sheath colour black (RAL 9005) DIN VDE 0472 part 804 test method B)

Note
Part no. 27012 (6x4).
G = with green-yellow conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
PVC type of flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this
purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface
of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded successively
so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5 mm, is very critical due to its low tensile stress. In such case, you should
add 10% reserve wire for calculation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight approx. cross-sec. dimension weight approx.
mm approx. mm kg / km kg / km mm approx. mm kg / km kg / km
26980 4 G 0,75 4,3 x 12,6 28,8 90,0 19 27006 12 G 1,5 4,5 x 38,9 173,0 421,0 16
26981 5 G 0,75 4,3 x 16,1 36,0 115,0 19 27028 16 G 1,5 4,5 x 51,5 230,4 555,0 16
26982 6 G 0,75 4,3 x 19,4 43,2 141,0 19 27030 24 G 1,5 4,5 x 83,0 346,0 820,0 16
26983 9 G 0,75 4,3 x 26,4 64,8 198,0 19 27007 4 G 2,5 5,5 x 17,0 96,0 205,0 14
26984 10 G 0,75 4,3 x 30,1 72,0 224,0 19 27008 5 G 2,5 5,5 x 21,5 120,0 256,0 14
26985 12 G 0,75 4,3 x 33,8 84,4 258,0 19 27009 7 G 2,5 5,5 x 30,3 168,0 344,0 14
26986 16 G 0,75 4,3 x 44,4 115,2 340,0 19 27010 8 G 2,5 5,5 x 31,9 192,0 389,0 14
26987 18 G 0,75 4,3 x 49,2 129,6 380,0 19 27011 12 G 2,5 5,8 x 47,1 288,0 580,0 14
26988 20 G 0,75 4,3 x 55,0 144,0 424,0 19 27029 16 G 2,5 5,8 x 55,1 384,0 674,0 14
26989 24 G 0,75 4,3 x 65,6 172,8 509,0 19 27012 24 G 2,5 15,0 x 63,0 604,0 950,0 14
26990 3G1 4,5 x 10,8 28,8 80,0 18 27027 24 G 2,5 5,8 x 120,0 604,0 950,0 14
26991 4G1 4,5 x 13,4 38,4 104,0 18 27013 4G4 7,0 x 21,8 154,0 344,0 12
26992 5G1 4,5 x 16,0 48,0 134,0 18 27014 5G4 7,0 x 27,4 192,0 428,0 12
26993 6G1 4,5 x 20,6 57,6 161,0 18 27015 7G4 7,9 x 36,6 269,0 590,0 12
26994 9G1 4,5 x 28,4 86,4 230,0 18 27016 4G6 8,2 x 24,8 230,0 424,0 10
26995 10 G 1 4,5 x 30,0 96,0 256,0 18 27017 5G6 8,2 x 31,8 288,0 530,0 10
26996 12 G 1 4,5 x 36,2 115,2 298,0 18 27018 7G6 8,2 x 42,6 403,0 760,0 10
26997 16 G 1 4,5 x 47,6 153,6 395,0 18 27019 4 G 10 10,0 x 29,6 384,0 710,0 8
26998 18 G 1 4,5 x 52,8 172,8 441,0 18 27020 4 G 16 11,2 x 34,4 614,0 1014,0 6
26999 20 G 1 4,5 x 59,0 192,0 495,0 18 27025 5 G 16 13,0 x 46,6 768,0 1370,0 6
27000 24 G 1 4,5 x 70,4 230,4 590,0 18 27021 4 G 25 13,7 x 42,6 960,0 1365,0 4
27001 4 G 1,5 4,5 x 13,7 58,0 133,0 16 27026 5 G 25 15,5 x 55,5 1200,0 2000,0 4
27002 5 G 1,5 4,5 x 17,9 72,0 169,0 16 27022 4 G 35 15,4 x 47,6 1344,0 2100,0 2
27003 7 G 1,5 4,5 x 23,5 101,0 235,0 16 27023 4 G 50 18,2 x 57,0 1920,0 2940,0 1
27004 8 G 1,5 4,5 x 26,8 115,0 265,0 16 27024 4 G 70 20,0 x 64,2 2688,0 4090,0 2/0
27005 10 G 1,5 4,5 x 33,5 144,0 332,0 16

Dimensions and specifications may be changed without prior notice. (RJ01)

276
Flat and Ribbon Cables

NEO-Flat (N)GFLGU

Technical data Cable structure Properties


Special Neoprene-flat cable adapted Copper-conductor bare or tinned to Special rubber outer sheath, cold-resistant
to DIN VDE 0250 part 809 DIN VDE 0295, BS 6360, IEC 60228 Extensively oil resistant,
Temperature range Conductor construcktion oil-/chemical resistance
flexing -30C to +80C 35-120 mm class 5: fine-wire see table Technical Informations
fixed installation -40C to +80C 1,5-25 mm class 6 col.4: extra-fine-wire Extremely small bending radius
Nominal voltage U0/U 300/500 V Special rubber core insulation High flexibility
Test voltage 3000 V Core identification to DIN VDE 0293 Minimum waste of space
Minimum bending radius - up to 5 cores coloured Packeting possibility
10x cable thickness - from 7 cores, black with continuous Outdoor application
Radiation resistance white numbering Tests
up to 50x106 cJ/kg (up to 50 Mrad) Cores laying parallel Behaviour in fire
GN-YE conductor to DIN VDE 0482-332-1-2
Outer sheath of special rubber DIN EN 60332-2-1, IEC 60332-1 (equivalent
5GM3, to DIN VDE 0207 part 21 DIN VDE 0472 part 804 test method B)
Sheath colour black
Note
G = with green-yellow conductor
Part no. 28007 and 28013 (6x4). J
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Neoprene type of flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units. These cables are
also available for export with UL-approval on request.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this
purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface
of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded successively
so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5 mm, is very critical due to its low tensile stress. In such case, you should
add 10% reserve wire for calculation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight approx. cross-sec. dimension weight approx.
mm approx. mm kg / km kg / km mm approx. mm kg / km kg / km
28001 4 G 1,5 5,9 x 16,2 58,0 234,0 16 28022 4 G 16 11,6 x 35,6 614,0 1430,0 6
28002 5 G 1,5 5,9 x 23,7 72,0 304,0 16 28023 5 G 16 12,2 x 48,2 768,0 1590,0 6
28003 7 G 1,5 5,9 x 30,5 101,0 391,0 16 28024 4 G 25 14,1 x 45,8 960,0 1890,0 4
28004 8 G 1,5 5,9 x 34,0 115,0 441,0 16 28025 5 G 25 14,7 x 58,3 1200,0 2215,0 4
28005 10 G 1,5 5,9 x 43,5 144,0 460,0 16 28026 7 G 25 15,3 x 78,7 1680,0 3000,0 4
28006 12 G 1,5 6,5 x 50,4 173,0 646,0 16 28027 4 G 35 15,8 x 50,8 1344,0 2460,0 2
28007 24 G 1,5 (6 x 4) 13,0 x 56,0 346,0 1290,0 16 28028 5 G 35 16,4 x 64,4 1680,0 2880,0 2
28008 4 G 2,5 7,2 x 19,6 96,0 316,0 14 28029 7 G 35 16,4 x 86,4 2352,0 4100,0 2
28009 5 G 2,5 7,2 x 27,8 120,0 391,0 14 28030 4 G 50 18,6 x 60,2 1920,0 3385,0 1
28010 7 G 2,5 7,2 x 36,1 168,0 533,0 14 28031 4 G 70 21,0 x 68,0 2688,0 4480,0 2/0
28011 8 G 2,5 7,2 x 40,2 192,0 602,0 14 28032 4 G 95 24,1 x 78,6 3648,0 5990,0 3/0
28012 12 G 2,5 7,8 x 59,4 288,0 890,0 14 28033 4 G 120 25,5 x 84,2 4608,0 7240,0 4/0
28013 24 G 2,5 (6 x 4) 15,5 x 66,8 576,0 1480,0 14
28014 4G4 8,8 x 24,2 154,0 506,0 12
28015 5G4 8,8 x 33,4 192,0 621,0 12
28016 7G4 8,8 x 42,5 269,0 851,0 12
28017 4G6 9,6 x 27,4 230,0 661,0 10
28018 5G6 9,6 x 37,4 288,0 740,0 10
28019 7G6 9,6 x 47,2 403,0 1004,0 10
28020 4 G 10 10,4 x 30,8 384,0 1027,0 8
28021 5 G 10 10,4 x 41,6 480,0 1171,0 8

Dimensions and specifications may be changed without prior notice. (RJ01)

277
Flat and Ribbon Cables

PVC-flat-CY screened, EMC-preferred type

Technical data Cable structure Properties


Special PVC-flat cable, screened, Bare copper-conductor, to Extensively oil resistant
adapted to DIN VDE 0283 part 2 DIN VDE 0295 cl.5, fine-wire, PVC self-extinguishing and flame retardant
Temperature range BS 6360 cl.5, IEC 60228 cl.5 acc. to DIN VDE 0482-332-1-2,
flexing -5C to +70C Core insulation of special PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation -40C to +80C Core identification see table below DIN VDE 0472 part 804 test method B)
Nominal voltage U0/U 300/500 V Cores screened individually or in bunches
Test voltage 3000 V Copper screened braiding, Note
Breakdown voltage approx. 85% coverage G = with green-yellow conductor
min. 6000 V Outer sheath of special PVC x = without green-yellow conductor
Minimum bending radius Sheath colour black (RAL 9005) AWG sizes are approximate equivalent
15x cable thickness values. The actual cross-section is in mm.
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
PVC screened flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this
purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface
of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded successively
so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5 mm, is very critical due to its low tensile stress. In such case, you should
add 10% reserve wire for calculation.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Core Outer Cop. Weight AWG-No.


cross-sec. marking dimension weight approx.
mm approx. mm kg / km kg / km
27100 5 G 0,5 Colour coded, DIN VDE 0293 21,0 x 3,4 64,0 140,0 20
27101 5 x 4 x 0,5 Colour coded, (blue, red, green, yellow) 37,4 x 7,2 175,0 280,0 20
27102 8 x 7 x 0,5 Cont. white numbering, DIN VDE 0293 68,6 x 11,7 480,0 1180,0 20
27090 4 G 0,75 Colour coded, DIN VDE 0293 15,0 x 5,0 70,0 147,0 19
27103 4x4G1 Cont. white numbering 33,5 x 11,0 310,0 625,0 18
26754 4x4x1 Colour coded, (blue, red, green, yellow) 33,5 x 11,0 310,0 625,0 18
27091 4 G 1,5 Colour coded, DIN VDE 0293 18,7 x 5,9 116,0 210,0 16
27092 8 G 1,5 Cont. white numbering 35,6 x 5,9 217,0 400,0 16
27093 12 G 1,5 Cont. white numbering 52,1 x 5,9 266,0 610,0 16
27094 4 G 2,5 Colour coded, DIN VDE 0293 21,0 x 6,9 170,0 270,0 14
27104 6 G 2,5 Cont. white numbering, DIN VDE 0293 37,4 x 7,2 240,0 320,0 14
27095 4G4 Colour coded, DIN VDE 0293 24,5 x 7,7 225,0 400,0 12
27096 4G6 Colour coded, DIN VDE 0293 30,1 x 9,2 328,0 520,0 10
27097 4 G 10 Colour coded, DIN VDE 0293 35,8 x 10,5 525,0 840,0 8
27098 4 G 16 Colour coded, DIN VDE 0293 41,3 x 12,6 788,0 1280,0 6
27099 4 G 25 Colour coded, DIN VDE 0293 48,4 x 14,4 1170,0 1800,0 4

Dimensions and specifications may be changed without prior notice. (RJ01)

Suitable accessories can be found in Chapter X.


Cable Gland - STK-F
Cable Gland - STS-F

278
Flat and Ribbon Cables

NEO-Flat-C (MCHU) screened, EMC-preferred type

Technical data Cable structure Properties


Special-Neoprene-flat cable, screened, Copper-conductor bare or tinned to Outer sheath cold resistant
adapted to DIN VDE 0250 part 809 DIN VDE 0295 cl.6, extra fine-wire, Extensively oil resistant
Temperature range BS 6360 cl.6, IEC 60228 cl.6 Extremely small bending radius
flexing -30C bis +80C Core insulation of special rubber High flexibility
fixed installation -40C to +80C Core identification to DIN VDE 0293 Minimum waste of space
Nominal voltage U0/U 300/500 V - up to 5 cores coloured Packeting possibility
Test voltage 3000 V - from 7 cores, black with continuous The high degree of screening density assures
Minimum bending radius white numbering disturbance-free transmission of all signal and
15x cable thickness GN-YE conductor impulses
Radiation resistance Cores screened individually Outdoor application
up to 50x106 cJ/kg (up to 50 Mrad) Cores laying parallel Tests
Copper screened braiding, Behaviour in fire
approx. 85% coverage to DIN VDE 0482-332-1-2
Outer sheath of special Neoprene DIN EN 60332-2-1, IEC 60332-1 (equivalent
Outer sheath coulor black (RAL 9005) DIN VDE 0472 part 804 test method B)

Note
G = with green-yellow conductor J
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Neoprene screened flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units. These cables are
also available for export with UL-approval on request.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this
purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface
of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded successively
so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5 mm, is very critical due to its low tensile stress. In such case, you should
add 10% reserve wire for calculation.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight approx. cross-sec. dimension weight approx.
mm approx. mm kg / km kg / km mm approx. mm kg / km kg / km
28100 8 G 1,5 7,9 x 42,0 231,0 520,0 16 28103 6 G 2,5 8,5 x 34,5 247,0 540,0 14
28101 12 G 1,5 7,9 x 61,0 346,0 790,0 16 28104 12 G 2,5 8,9 x 68,0 494,0 1000,0 14
28102 4 G 2,5 8,5 x 25,5 164,0 420,0 14 28302 4 G 25 16,0 x 51,0 1116,0 1650,0 4

Dimensions and specifications may be changed without prior notice. (RJ01)

Suitable accessories can be found in Chapter X.


Cable Gland - STK-F
Cable Gland - STS-F

279
Flat and Ribbon Cables

Ribbon Cables Type L, Type L AWG 28, Type D

Technical data Cable structure Properties


Type L (stranded wire) Type L (stranded wire) Type L AWG 28 ( stranded wire)
Pitch 2,54 mm Tinned copper, fine wire stranded to PVC self-extinguishing and flame retardant
Nominal voltage DIN VDE 0295 cl.5, BS 6360 cl.5 acc. to DIN VDE 0482-332-1-2,
0,14 mm = 350 V Core insulation of PVC, flame retardant DIN EN 60332-1-2, IEC 60332-1 (equivalent
0,25 to 0,75 mm = 600 V Cores colour coded DIN VDE 0472 part 804 test method B)
Test voltage Type L AWG 28 (stranded wire)
0,14 mm = 1200 V Tinned copper 7x0,127 Note
0,25 to 0,75 mm = 2000 V Core insulation of PVC, flame retardant Pitch
Type L AWG 28 (stranded wire) Cores single coloured, edge marking on (Distance between centre point)
Pitch 1,27 mm one side
Heat-resistance up to 105C Cores moulded, can be separated easily
Nominal voltage 300 V Type D (solid)
Test voltage 2000 V Cu-solid, tinned 0,5 mm
Type D (solid) Core insulation of PVC
Pitch 2,5 mm Cores moulded, can be separated easily
Nominal voltage 500 V Cores colour coded
Test voltage 1500 V

Application
Ribbon cables are used as connecting and control cables wherever there is a need to install quickly and with a minimum waste of space. These cables
offer an excellent degree of flexibility.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Typ L (colour coded) Typ L AWG 28 (single coloured, edge marking on one side)
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
44001 2 x 0,14 3,9 x 1,4 2,7 7,0 26 44041 10 x 0,08 12,7 x 0,9 13,4 30,0 28
44002 3 x 0,14 6,4 x 1,4 4,0 11,0 26 44042 14 x 0,08 17,8 x 0,9 18,0 50,0 28
44003 4 x 0,14 8,9 x 1,4 5,4 14,0 26 44043 16 x 0,08 20,3 x 0,9 20,0 53,0 28
44004 5 x 0,14 11,3 x 1,4 6,7 18,0 26 44044 20 x 0,08 25,4 x 0,9 25,0 65,0 28
44005 6 x 0,14 13,9 x 1,4 8,1 21,0 26 44045 26 x 0,08 33,0 x 0,9 32,0 75,0 28
44006 7 x 0,14 16,4 x 1,4 9,4 25,0 26 44046 34 x 0,08 43,2 x 0,9 43,0 90,0 28
44007 8 x 0,14 18,9 x 1,4 10,7 28,0 26 44047 40 x 0,08 50,8 x 0,9 48,0 125,0 28
44008 9 x 0,14 21,4 x 1,4 13,4 32,0 26 44048 48 x 0,08 61,0 x 0,9 59,0 145,0 28
44009 10 x 0,14 23,9 x 1,4 14,4 35,0 26
44010 11 x 0,14 26,4 x 1,4 15,3 39,0 26 Typ D (colour coded)
44011 12 x 0,14 28,9 x 1,4 16,1 42,0 26 Part no. No.cores x Outer Cop. Weight AWG-No.
44012 16 x 0,14 38,9 x 1,4 21,5 56,0 26 cross-sec. approx. mm weight approx.
44013 20 x 0,14 48,9 x 1,4 27,0 70,0 26 mm kg / km kg / km
44014 4 x 0,25 9,1 x 1,6 9,6 21,0 24 44049 2 x 0,5 3,9 x 1,4 10,0 10,0 20
44015 5 x 0,25 11,6 x 1,6 12,0 26,0 24 44050 3 x 0,5 6,4 x 1,4 14,0 14,0 20
44016 6 x 0,25 14,1 x 1,6 14,4 31,0 24 44051 4 x 0,5 8,9 x 1,4 19,0 17,0 20
44017 7 x 0,25 16,6 x 1,6 16,8 36,0 24 44052 5 x 0,5 11,4 x 1,4 24,0 21,0 20
44018 8 x 0,25 19,1 x 1,6 19,2 42,0 24 44053 6 x 0,5 13,9 x 1,4 29,0 25,0 20
44019 10 x 0,25 24,1 x 1,6 24,0 52,0 24 44054 7 x 0,5 16,4 x 1,4 34,0 29,0 20
44020 12 x 0,25 29,1 x 1,6 28,8 62,0 24 44055 8 x 0,5 18,9 x 1,4 38,0 33,0 20
44021 16 x 0,25 39,1 x 1,6 38,4 83,0 24 44056 9 x 0,5 21,4 x 1,4 42,0 37,0 20
44022 20 x 0,25 49,1 x 1,6 48,0 104,0 24 44057 10 x 0,5 23,9 x 1,4 48,0 41,0 20
44023 4 x 0,5 9,0 x 2,0 19,2 38,0 20 44058 11 x 0,5 26,4 x 1,4 56,0 47,0 20
44024 5 x 0,5 12,0 x 2,0 24,0 48,0 20
44025 6 x 0,5 15,0 x 2,0 28,8 57,0 20
44026 7 x 0,5 17,0 x 2,0 33,6 66,0 20
44027 8 x 0,5 20,0 x 2,0 38,4 76,0 20
44028 10 x 0,5 23,0 x 2,0 48,0 95,0 20
44029 12 x 0,5 30,0 x 2,0 58,0 114,0 20
44030 16 x 0,5 40,0 x 2,0 77,0 151,0 20
44031 20 x 0,5 50,0 x 2,0 101,0 190,0 20
44032 4 x 0,75 10,6 x 2,5 29,0 52,0 19
44033 5 x 0,75 13,3 x 2,5 36,0 64,0 19
44034 6 x 0,75 16,0 x 2,5 43,2 77,0 19
44035 7 x 0,75 18,7 x 2,5 50,0 90,0 19
44036 8 x 0,75 21,4 x 2,5 58,0 103,0 19
44037 10 x 0,75 26,8 x 2,5 72,0 130,0 19
44038 12 x 0,75 32,2 x 2,5 86,0 155,0 19
44039 16 x 0,75 43,0 x 2,5 112,0 206,0 19
44040 20 x 0,75 53,4 x 2,5 151,0 260,0 19

Dimensions and specifications may be changed without prior notice. (RJ01)

280
Flat and Ribbon Cables

TUBEFLEX-Y roundshaped flat ribbon cable for IDC-technique, pitch 1,27 mm

Technical data Cable structure Properties


Roundshaped special Flat Ribbon Cable Stranded tinned copper conductor, The materials used in manufacture are
Conductor resistance at 20C size AWG 28 cadmium-free and contain no silicone
max. 230 Ohm/km 7x0,127 mm = 0,09 mm and free from substances harmful to
Temperature range Core insualtion of special PVC the wetting properties of lacquers
-20C up to +80C Cores colour grey, edge marking on one side Very interesting for cable
Voltage rating Cores laying parallel and adjacent, alternately pre-assemblers!
max. 300 V spliced or separated and periodically slotted Tests
Test voltage Roundshaped flat ribbon cable, folded PVC self-extinguishing and flame retardant
core/core 2000 V Taping acc. to DIN VDE 0482-332-1-2,
Dielectric strength, Spark-test Outer sheath of special PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
3000 V Outer sheath Colour grey DIN VDE 0472 part 804 test method B)
Insulation resistance
min. 20 MOhm x km
Capacitance (side cores)
ca. 75 pF/m
Impedance 115 Ohm

J
Minimum bending radius
15x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
TUBEFLEX-Y Flat ribbon cable, due to its roundshape offers considerable advantages compared with other flat ribbon cables during the installation
and assembly. This roundshaped cable bids enormous profits by using the quick and economical possibilities under continuance with the efficient
connection in IDC-technique. All conductors can be contacted at one working procedure without stripping the insulation. The accurate to size
pitch-image of the ribbon cable is obtained due to an adapted backshaping before the plug installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part No.cores Flat ribbon Outer Outer Cop. Weight Part No.cores Flat ribbon Outer Outer Cop. Weight
no. x AWG-No. dimension sheath approx. weight approx. no. x AWG-No. dimension sheath approx. weight approx.
Width mm nominal mm kg / km kg / km Width mm nominal mm kg / km kg / km
wall- wall-
thickness thickness
mm mm
45130 9 x 28 11,43 0,8 6,1 8,7 35,0 45138 30 x 28 38,10 0,8 9,0 29,0 81,0
45131 10 x 28 12,70 0,8 6,2 9,7 36,0 45139 34 x 28 43,20 0,8 10,0 32,9 87,0
45132 14 x 28 17,78 0,8 7,2 13,6 48,0 45140 36 x 28 45,72 0,8 10,2 34,9 91,0
45133 16 x 28 20,30 0,8 7,2 15,5 51,0 45141 37 x 28 47,00 1,0 10,3 35,8 93,0
45134 20 x 28 25,40 0,8 7,3 19,4 57,0 45142 40 x 28 50,80 1,0 10,7 38,7 101,0
45135 24 x 28 30,48 0,8 8,6 23,2 66,0 45143 50 x 28 63,50 1,0 11,1 48,4 118,0
45136 25 x 28 31,75 0,8 8,6 24,2 69,0 45144 60 x 28 76,20 1,0 12,5 58,1 135,0
45137 26 x 28 33,02 0,8 8,6 25,2 70,0 45145 64 x 28 81,30 1,0 13,0 62,0 147,0

Dimensions and specifications may be changed without prior notice. (RJ01)

Suitable accessories can be found in Chapter X.


Cable Gland - STK-F
Cable Gland - STS-F

281
Flat and Ribbon Cables

TUBEFLEX-(St)-CY roundshaped flat ribbon cable, screened, for IDC-technique,


pitch 1,27mm, EMC-preferred type

Technical data Cable structure Properties


Roundshaped special Flat Ribbon Cable, Stranded tinned copper conductor, The materials used in manufacture are
screened size AWG 28 cadmium-free and contain no silicone and free
Conductor resistance at 20C 7x0,127 mm = 0,09 mm from substances harmful to the wetting
max. 230 Ohm/km Core insualtion of special PVC properties of lacquers
Temperature range Cores colour grey, edge marking on one side Very interesting for cable
-20C up to +80C Cores laying parallel and adjacent, alternately pre-assemblers!
Voltage rating spliced or separated and periodically slotted The dual shielding with plastic coated
max. 300 V Roundshaped flat ribbon cable, folded aluminium foil (St) and the additional tinned
Test voltage Dual shielding: copper wire braiding (C) protects against high
core/core 2000 V (St) - plastic coated Alu-foil and frequency interference and ensures
core/screen 2000 V C - tinned copper wire braiding with optimal disturbance-free signal and impuls transfer.
Dielectric strength, Spark-test surface coverage Tests
3000 V Outer sheath of special PVC PVC self-extinguishing and flame retardant
Insulation resistance Outer sheath Colour grey acc. to DIN VDE 0482-332-1-2,
min. 20 MOhm x km DIN EN 60332-1-2, IEC 60332-1 (equivalent
Capacitance (side cores) DIN VDE 0472 part 804 test method B)
ca. 75 pF/m
Impedance 115 Ohm
Minimum bending radius
15x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
TUBEFLEX-(St)-CY Flat ribbon cable, due to its roundshape offers considerable advantages compared with other flat ribbon cables during the installation
and assembly. This roundshaped cable bids enormous profits by using the quick and economical possibilities under continuance with the efficient
connection in IDC-technique. All conductors can be contacted at one working procedure without stripping the insulation. The accurate to size
pitch-image of the ribbon cable is obtained due to an adapted backshaping before the plug installation.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part No.cores Flat ribbon Outer Outer Cop. Weight Part No.cores Flat ribbon Outer Outer Cop. Weight
no. x AWG-No. dimension sheath approx. weight approx. no. x AWG-No. dimension sheath approx. weight approx.
Width mm nominal mm kg / km kg / km Width mm nominal mm kg / km kg / km
wall- wall-
thickness thickness
mm mm
45150 9 x 28 11,43 0,8 6,3 30,9 56,0 45161 37 x 28 47,00 1,0 10,5 71,1 128,0
45151 10 x 28 12,70 0,8 6,4 31,9 57,0 45162 40 x 28 50,80 1,0 11,3 74,1 135,0
45152 14 x 28 17,78 0,8 7,2 35,6 70,0 45163 50 x 28 63,50 1,0 11,6 88,3 160,0
45153 16 x 28 20,30 0,8 7,4 42,0 75,0 45164 60 x 28 76,20 1,0 12,9 98,7 172,0
45154 20 x 28 25,40 0,8 7,8 45,8 83,0 45165 64 x 28 81,30 1,0 13,3 107,2 192,0
45155 24 x 28 30,48 0,8 9,0 54,3 97,0
45156 25 x 28 31,75 0,8 9,0 55,2 100,0
45157 26 x 28 33,02 0,8 9,0 60,0 101,0
45158 30 x 28 38,10 0,8 9,2 60,4 113,0
45159 34 x 28 43,20 0,8 10,2 68,1 122,0
45160 36 x 28 45,72 0,8 10,4 70,1 126,0

Dimensions and specifications may be changed without prior notice. (RJ01)

Suitable accessories can be found in Chapter X.


Cable Gland - STK-F
Cable Gland - STS-F

282
SINGLE CONDUCTORS

3
in

E
VD eld 29
ng

x
xe
ex

VD
d
U

R/ shi E 0
xi
- fi
- fl

xe

./
0 /

le

ed
i

no
H A ed / VD
-f

f
U
C)

C)

s-
ge

us

CS REG
e n es /
(

e
lta

di

di

se
re

re

t
V- -fre

ut tan

r
n
ra

ra

co
tu

tu

u
vo

E
ai
or
sis
ra

ra

n
g

A
d
ch
al

ge
in

in
pe

pe

re
do
re
in

ge
nd

nd

ag
lo

lo

re
m

L/
om

Ha

Co

Pa
Be

Be

Dr

Sc
Te

Te

O
U

U
N
Single Conductors

LiYv -5 to +70 -30 to +80 500 4x X 287

H05V-K -5 to +70 -30 to +80 300/500 4x X X 289

H07V-K / (H)07V-K -5 to +70 -30 to +80 450/750 6x X X 291

H05V-K / (H)07V-K -5 to +70 -30 to +80 300/500 6x X X 293

H05V-U / H07V-U -5 to +70 -30 to +80 300/500 6x X X 294

H07V-R -5 to +70 -30 to +80 450/750 6x X X 295


H05V-K, H07V-K,
296
LiY - barrel opening
TOPFLEX 303 X07V-K-Y -5 to +80 -40 to +80 0,6/1kV 12x 12x X 297

LifY single core -15 to +80 -15 to +80 300/500 8x 8x X 298

PUR single cores -40 to +80 1kV 10x 5x X X X X 299

H05Z-K / H07Z-K -40 to +90 300/500 6x X X X 300

H05G-U / -K / H07G-U / -R / -K -25 to +110 -40 to +110 300/500 6x X X 302


+5 to
LiYW / H05V2-K +5 to +90 300/500 4x X 303
-90/105
H07V2-K +5 to +90 +5 to +90 450/750 10-15x X X 304
K
HELUTHERM 145
-35 to +120 -55 to +145 300/500 12,5x 4x X X X X 305

SiF / SiFF -60 to +180 300/500 6x X X 307

SiF/GL, SiD, SiD/GL -60 to +180 300/500 15x 15x X X 308

FZ-LSi +180 +180 6-10kV 7,5x 7,5x X 309

FZ-LS +180 +180 15-20kV 7,5x 7,5x X 309

Neon Light Cables +180 +180 3,5-7,5kV 7,5x 7,5x X X 309

HELUFLON -FEP-6Y -100 to +205



-100 to +205 600 10x 4x X X X 310

HELUFLON-PTFE-5Y -190 to +260 -190 to +260 600 10x 4x X X X 311

HELUFLON-PTFE-5Y -190 to +260 -190 to +260 1000 10x 4x X X X 311

HELUTHERM 400
-60 to +400 500 15x 15x X X 312

HELUTHERM 600 / 600-ES -60 to +600 500 15x 15x X /X 313

HELUTHERM 800 / 800-ES -120 to +750 500 15x 15x X /X 314

HELUTHERM 1200 / 1200-ES -170 to +1000 500 15x 15x X /X 315

Ground wire ESUY/ESY -5 to +70 -5 to +70 12x 12x 316

GALVANIC CABLE -40 to + 80 -50 to +80 0,6/1kV 15x 15x X X X 317

H01N2-D / -E -25 to +80 -40 to +80 100/100 12x/10x 12x/10x X X 318

NSGAFU 3kV -25 to +80 -40 to +80 1,8/3kV 10x 6x X 319

NSHXAF 3kV -25 to +70 -40 to +90 1,8/3kV 10x 6x X X 320

TOPFLEX 300

-5 to +80 -40 to +80 0,6/1kV 7,5x 7,5x (X) X 321

KOMPOSPEED 600 / 600-C -30 to +90 -40 to +100 0,6/1kV 5/7,5x 3/4x X X X X /X 322

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

285
SELECTION TABLE - DRAG CHAIN CABLES

ng
in

xi

g
/s 2
ce

fle

in
/
an

ex
ge U
(m
-
es ist

lta 0 /

- fl
us

)
-c t d

vo U
/s
di

io
)

C)
g ge
en

(m
ra

at
or

(
tin lta
er
m

re
in

s
25
e

el

nt
ra vo
ee

le

ui CSA
ov

nd

tu

s
c

yc
)

al
to

le
sp

ac

pe l

ra
ia
m

O ina
be

ov
r

.c
up

va
te

eq L/
er

pe
.

ge
.

ax

ax
ou

pr
ax
ax
m

om
.

at
in

U
m
=

Ap
M

M
0

Pa
M
M

M
M
(D
(1

Te
N
Single cores for drag chain cables
KOMPOSPEED 600 100 5xD 4 10 11 Mio Poly/ Poly 600/1000V -30 to +90 322 504
KOMPOSPEED 600-C

100 7.5 x D 4 10 11 Mio Poly/CU/Poly 600/1000V -30 to +90 322 505
TOPFLEX 300 5 7.5 x D 2 10 9 Mio PVC/PVC 600/1000V -5 to +80 321 500

A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties and the selection tables cables in drag chains,
see pages 1030 and 1031.

286
Single Conductors

LiYv PVC-Single Cores, fine wire stranded, tinned

Technical data Cable structure Properties


PVC single cores adapted to Tinned copper-conductor, to The materials used in manufacture are
DIN VDE 0812 DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
Temperature range BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
flexing -5C to +70C Core insulation of PVC the wetting properties of lacquers
fixed installation -30C to +80C compound type YI3 to Tests
Operating peak voltage DIN VDE 0812 PVC self-extinguishing and flame retardant
0,14 mm = 500 V Core identification see table below acc. to DIN VDE 0482-332-1-2,
0,25-1,5 mm = 900 V DIN EN 60332-1-2, IEC 60332-1 (equivalent
Test voltage DIN VDE 0472 part 804 test method B)
0,14 mm = 1200 V
0,25-1,5 mm = 2500 V Note
Insulation resistance For 2-coloured combinations ring marking.
min. 10 MOhm x km
Minimum bending radius
fixed installation 4x core
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
PVC insulated flexible hook-up wires are used for the connection for low voltage applications, communication apparatus, electronic assemblies and
equipment, racks, switchboards etc. correspondingly of VDE 0800 part 1 for the temperature range up to +70C. Those stranded hook-up wires are
not permitted to install for heavy current application outside of the equipment.
K
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
LiYv
Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
sec. approx. mm weight
mm kg / km
approx. RAL 9005 - 5015 8003 3000 9003 7000 4005 1021 3015 6018 - 5010 2003 - -

Packing Spool (standard 100m capacity)


LiYv spool
Part no. 26405 26406 26407 26408 26409 26410 26411 26412 26413 26414 26415 26416 26417 26418 26419 26420
0,14 1,1 1,4
Part no. 26421 26422 26423 26424 26425 26426 26427 26428 26429 26430 26431 26432 26433 26434 26435 26436
0,25 1,3 2,4
Part no. 26437 26438 26439 26440 26441 26442 26443 26444 26445 26446 26447 26448 26449 26450 26451 26452
0,5 1,8 4,8
Part no. 26453 26454 26455 26456 26457 26458 26459 26460 26461 26462 26463 26464 26465 26466 26467 26468
0,75 2,0 7,2
Part no. 26469 26470 26471 26472 26473 26474 26475 26476 26477 26478 26479 26480 26481 26482 26483 26484
1 2,1 9,6
Part no. 26485 26486 26487 26488 26489 26490 26491 26492 26493 26494 26495 26496 26497 26498 26499 26500
1,5 2,6 14,4

Continuation

287
Single Conductors

LiYv PVC-Single Cores, fine wire stranded, tinned


LiYv
Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
sec. approx. mm weight
mm kg / km
approx. RAL 9005 - 5015 8003 3000 9003 7000 4005 1021 3015 6018 - 5010 2003 - -

Packing Barrel (with various capacity)


LiYv barrel
Part no. 26505 26506 26507 26508 26509 26510 26511 26512 26513 26514 26515 26516 26517 26518 26519 26520
0,25 1,3 2,4
Part no. 26521 26522 26523 26524 26525 26526 26527 26528 26529 26530 26531 26532 26533 26534 26535 26536
0,5 1,8 4,8
Part no. 26537 26538 26539 26540 26541 26542 26543 26544 26545 26546 26547 26548 26549 26550 26551 26552
0,75 2,0 7,2
Part no. 26553 26554 26555 26556 26557 26558 26559 26560 26561 26562 26563 26564 26565 26566 26567 26568
1 2,1 9,6
Part no. 26569 26570 26571 26572 26573 26574 26575 26576 26577 26578 26579 26580 26581 26582 26583 26584
1,5 2,6 14,4

Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

288
Single Conductors

H05V-K PVC-Single Cores, fine wire stranded

Technical data Cable structure Properties


PVC single cores to Bare Cu-conductor, to The materials used in manufacture are
DIN VDE 0285-525-2-31 / DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN EN 50525-2-31 and IEC 60227-3 BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
Temperature range Core insulation of PVC the wetting properties of lacquers
flexing -5C to +70C compound type TI1 to Tests
fixed installation -30C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
Nominal voltage U0/U 300/500 V and IEC 60227-3 acc. to DIN VDE 0482-332-1-2,
Test voltage 2000 V Core identification see table below DIN EN 60332-1-2, IEC 60332-1 (equivalent
Insulation resistance DIN VDE 0472 part 804 test method B)
min. 10 MOhm x km
Minimum bending radius Note
fixed insatallation 4x core The following colours are recommended:
Radiation resistance black, white, blue, grey, brown, red,
up to 80x106 cJ/kg (up to 80 Mrad) orange, turquoise, violet and pink.
Exceptions are the colours green and
yellow; these are only permitted if the
safety regulations allows. Green is
permitted for the identification of
luminous decorative chains. All
2-coloured combinations of the
abovesingle colours are allowed K
Application
These single cores are determined for the installation to the inside of apparatus as well as for the protective laying to the lightings, in dry rooms, in
production facilities, switch and distributor boards, in tubes, under and surface mounting of plasters.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05V-K
Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col. U-BU
sec. min. - max. weight
mm mm kg / km
approx. RAL 9005 - 5015 8003 3000 9003 7001 4005 1021 3015 6018 - 5010 2003 - - 5002

Packing Coil in cardboard (100m)


H05V-K coil
Part no. 29081 29082 29083 29084 29085 29086 29087 29088 29089 29090 29091 29092 29093 29094 29095 29096 26386
0,5 2,1 - 2,5 4,8
Part no. 29097 29098 29099 29100 29101 29102 29103 29104 29105 29106 29107 29108 29109 29110 29111 29112 26387
0,75 2,2 - 2,7 7,2
Part no. 29113 29114 29115 29116 29117 29118 29119 29120 29121 29122 29123 29124 29125 29126 29127 29128 26388
1 2,4 - 2,8 9,6

Packing Spool (with various capacity)


H05V-K spool
Part no. 26590 26591 26592 26593 26594 26595 26596 26597 26598 26599 26600 26601 26602 26603 26604 26605 26389
0,5 2,1 - 2,5 4,8
Part no. 26606 26607 26608 26609 26610 26611 26612 26613 26614 26615 26616 26617 26618 26619 26620 26621 26390
0,75 2,2 - 2,7 7,2
Part no. 26622 26623 26624 26625 26626 26627 26628 26629 26630 26631 26632 26633 26634 26635 26636 26637 26391
1 2,4 - 2,8 9,6

Continuation

289
Single Conductors

H05V-K PVC-Single Cores, fine wire stranded


H05V-K
Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col. U-BU
sec. min. - max. weight
mm mm kg / km
approx. RAL 9005 - 5015 8003 3000 9003 7001 4005 1021 3015 6018 - 5010 2003 - - -

Packing Barrel (with various capacity)


H05V-K barrel
Part no. 26640 26641 26642 26643 26644 26645 26646 26647 26648 26649 26650 26651 26652 26653 26654 26655 26392
0,5 2,1 - 2,5 4,8
Part no. 26656 26657 26658 26659 26660 26661 26662 26663 26664 26665 26666 26667 26668 26669 26670 26671 26393
0,75 2,2 - 2,7 7,2
Part no. 26672 26673 26674 26675 26676 26677 26678 26679 26680 26681 26682 26683 26684 26685 26686 26687 26394
1 2,4 - 2,8 9,6

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

290
Single Conductors

H07V-K / (H)07V-K PVC-Single Cores, fine wire stranded

Technical data Cable structure Properties


PVC single cores to Bare Cu-conductor, to The materials used in manufacture are
DIN VDE 0285-525-2-31/ DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN EN 50525-2-31 and IEC 60227-3 BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
Temperature range Core insulation of PVC the wetting properties of lacquers
flexing -5C to +70C compound type TI1 to Tests
fixed installation -30C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
Nominal voltage U0/U 450/750 V and IEC 60227-3 acc. to DIN VDE 0482-332-1-2,
Test voltage 2500 V Core identification see table below DIN EN 60332-1-2, IEC 60332-1 (equivalent
Insulation resistance DIN VDE 0472 part 804 test method B)
min. 10 MOhm x km
Minimum bending radius Note
fixed installation The following colours are recommended
core 8 mm: 4x core (only single colour): black, white, blue, grey,
core > 8-1 2 mm: 5x core brown, red, orange, turquoise, violet and
core > 12 mm: 6x core pink. Two-coloured combinations are not
Radiation resistance allowed, with exceptions of green-yellow.
up to 80x106 cJ/kg (up to 80 Mrad) Colours yellow, green, transparent only in
(H)07V-K available.
Two-coloured combination is only
permitted for (H)07V-K.

Application
K
These single cores are suitable for laying in tubes, under and surface mounting of plasters and also in closed installation conduits. These are not allowed
to install for direct laying on cable trays, channels or tanks. These types are permitted for the inner wiring of equipment, distributor and switchboards
and also for protective laying to the lightings with a nominal voltage up to 1000 V alternating current or up to 750 V direct current against earth.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H07V-K, (H)07V-K
Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG 2-col. U-BU
sec. min. - max. weight
mm mm kg / km
approx. RAL 9005 - 5015 8003 3000 9003 7001 4005 1021 3015 6018 - 5010 2003 - 5002

Packing Coil in cardboard (100m)


H07V-K coil
Part no. 29129 29130 29131 29132 29133 29134 29135 29136 29137 29138 29139 29140 29141 29142 29144 26395
1,5 2,8 - 3,4 14,4
Part no. 29145 29146 29147 29148 29149 29150 29151 29152 29153 29154 29155 29156 29157 29158 29160 26396
2,5 3,4 - 4,1 24,0
Part no. 29161 29162 29163 29164 29165 29166 29167 29168 29169 29170 29171 29172 29173 29174 29176 26397
4 3,9 - 4,8 38,0
Part no. 29177 29178 29179 29180 29181 29182 29183 29184 29185 29186 29187 29188 29189 29190 29192 26398
6 4,4 - 5,3 58,0

Packing Spool (with various capacity)


H07V-K spool
Part no. 26690 26691 26692 26693 26694 26695 26696 26697 26698 26699 26700 26701 26702 26703 26705 26399
1,5 2,8 - 3,4 14,4
Part no. 26706 26707 26708 26709 26710 26711 26712 26713 26714 26715 26716 26717 26718 26719 26721 26400
2,5 3,4 - 4,1 24,0
Part no. 26722 26723 26724 26725 26726 26727 26728 26729 26730 26731 26732 26733 26734 26735 26737 26401
4 3,9 - 4,8 38,0
Part no. 26738 26739 26740 26741 26742 26743 26744 26745 26746 26747 26748 26749 26750 26751 26753 26402
6 4,4 - 5,3 58,0

Continuation

291
Single Conductors

H07V-K / (H)07V-K PVC-Single Cores, fine wire stranded


H07V-K, (H)07V-K
Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG 2-col. U-BU
sec. min. - max. weight
mm mm kg / km
approx. RAL 9005 - 5015 8003 3000 9003 7001 4005 1021 3015 6018 - 5010 2003 - -

Packing Barrel (with various capacity)


H07V-K barrel
Part no. 26755 26756 26757 26758 26759 26760 26761 26762 26763 26764 26765 26766 26767 26768 26770 26403
1,5 2,8 - 3,4 14,4
Part no. 26771 26772 26773 26774 26775 26776 26777 26778 26779 26780 26781 26782 26783 26784 26786 26404
2,5 3,4 - 4,1 24,0
Part no. 26787 26788 26789 26790 26791 26792 26793 26794 26795 26796 26797 26798 26799 26800 26802 26819
4 3,9 - 4,8 38,0
Part no. 26803 26804 26805 26806 26807 26808 26809 26810 26811 26812 26813 26814 26815 26816 26818 26820
6 4,4 - 5,3 58,0

Packing Coil in foil (100m)


H07V-K coil
Part no. 26060 26061 26062 26063 26064 26065 26066 26067 26068 26069 26092 26099 26108 26109 26111 26821
1,5 2,8 - 3,4 14,4
Part no. 26112 26113 26114 26115 26116 26117 26118 26119 29855 29856 29857 29858 29859 29890 29892 26822
2,5 3,4 - 4,1 24,0
Part no. 29893 29894 29895 29896 29897 29898 29899 29905 29906 29907 29908 29909 29910 29911 29913 26823
4 3,9 - 4,8 38,0
Part no. 29914 29915 29916 29917 29918 29919 29921 29922 29923 29924 29925 29926 29927 29928 29933 26824
6 4,4 - 5,3 58,0
Part no. 29193 29194 29195 29196 29197 29198 29199 29200 29201 29202 29203 29204 29205 29206 29208 -
10 5,7 - 6,8 96,0
Part no. 29209 29210 29211 29212 29213 29214 29215 29216 29217 29218 29219 29220 29221 29222 29224 -
16 6,7 - 8,1 154,0
Part no. 29225 29226 29227 29228 29229 29230 29231 29232 29233 29234 29235 29236 29237 29238 29240 -
25 8,4 - 10,2 240,0
Part no. 29241 29242 29243 29244 29245 29246 29247 29248 29249 29250 29251 29252 29253 29254 29256 -
35 9,7 - 11,7 336,0
Part no. 29257 29258 29259 29260 29261 29262 29263 29264 29265 29266 29267 29268 29269 29270 29272 -
50 11,5 - 13,9 480,0
Part no. 29273 29274 29275 29276 29277 29278 29279 29280 29281 29282 29283 29284 29285 29286 29288 -
70 13,2 - 16,0 672,0
Part no. 29289 29290 29291 29292 29293 29294 29295 29296 29297 29298 29299 29300 29301 29302 29304 -
95 15,1 - 18,2 912,0
Part no. 29418 29419 29420 29421 29422 29423 29424 29425 29426 29427 29428 29429 29430 29431 29433 -
120 16,7 - 20,2 1152,0
Part no. 29434 29435 29436 29437 29438 29439 29440 29441 29442 29443 29444 29445 29446 29447 29449 -
150 18,6 - 22,5 1440,0
Part no. 29494 29495 29496 29497 29498 29499 29590 29591 29592 29593 29594 29595 29596 29597 29599 -
185 20,6 - 24,9 1776,0
Part no. 29813 29814 29815 29816 29817 29818 29819 29840 29841 29842 29843 29844 29845 29846 29848 -
240 23,5 - 28,4 2304,0

Packing Drum
H07V-K drum
Part no. 26825 26826 26827 26828 26829 26830 26831 26832 26833 26834 26835 26836 26837 26838 26840 -
10 5,7 - 6,8 96,0
Part no. 26841 26842 26843 26844 26845 26846 26847 26848 26849 26850 26851 26852 26853 26854 26856 -
16 6,7 - 8,1 154,0
Part no. 26857 26858 26859 26860 26861 26862 26863 26864 26865 26866 26867 26868 26869 26870 26872 -
25 8,4 - 10,2 240,0
Part no. 26873 26874 26875 26876 26877 26878 26879 26880 26881 26882 26883 26884 26885 26886 26888 -
35 9,7 - 11,7 336,0
Part no. 26889 26890 26891 26892 26893 26894 26895 26896 26897 26898 26899 26900 26901 26902 26904 -
50 11,5 - 13,9 480,0
Part no. 26905 26906 26907 26908 26909 26910 26911 26912 26913 26914 26915 26916 26917 26918 26920 -
70 13,2 - 16,0 672,0
Part no. 26921 26922 26923 26924 26925 26926 26927 26928 26929 26930 26931 26932 26933 26934 26936 -
95 15,1 - 18,2 912,0
Part no. 29305 29306 29307 29308 29309 29310 29311 29312 29313 29314 29315 29316 29317 29318 29320 -
120 16,7 - 20,2 1152,0
Part no. 29321 29322 29323 29324 29325 29326 29327 29328 29329 29330 29331 29332 29333 29334 29336 -
150 18,6 - 22,5 1440,0
Part no. 29337 29338 29339 29340 29341 29342 29343 29344 29345 29346 29347 29348 29349 29350 29352 -
185 20,6 - 24,9 1776,0
Part no. 29353 29354 29355 29356 29357 29358 29359 29360 29361 29362 29363 29364 29365 29366 29368 -
240 23,5 - 28,4 2304,0

Dimensions and specifications may be changed without prior notice. (RK01)

292
Single Conductors

H05V-K / (H)07V-K PVC-single cores, fine wire stranded, 2-colour


Cross- Outer Cop. RD/WH BU/WH BN/WH D-BU/WH
sec. min. - max. weight
mm mm kg / km

Packing Coil in cardboard (100m)


H05V-K coil
Part no. 29370 29375 29380 29394
0,5 2,1 - 2,5 4,8
Part no. 29371 29376 29381 29395
0,75 2,2 - 2,7 7,2
Part no. 29372 29377 29382 29396
1 2,4 - 2,8 9,6

Packing Coil in cardboard (100m)


(H)07V-K coil
Part no. 29373 29378 29383 29397
1,5 2,8 - 3,4 14,4
Part no. 29374 29379 29384 29398
2,5 3,4 - 4,1 24,0
Part no. 29385 29386 29387 29399
4 3,9 - 4,8 38,0
Part no. 29388 29389 29390 29527
6 4,4 - 5,3 58,0
Part no. 29391 29392 29393 29528
10 5,7 - 6,8 96,0

Packing Spool (with various capacity)


H05V-K spool
Part no. 29745 29746 29747 29748
0,5 2,1 - 2,5 4,8
Part no. 29749 29750 29751 29752
0,75
Part no.
1
2,2 - 2,7

2,4 - 2,8
7,2

9,6
29753 29754 29755 29756 K
Packing Spool (with various capacity)
(H)07V-K spool
Part no. 29757 29758 29759 29760
1,5 2,8 - 3,4 14,4
Part no. 29761 29762 29763 29764
2,5 3,4 - 4,1 24,0
Part no. 29765 29766 29767 29768
4 3,9 - 4,8 38,0
Part no. 29769 29770 29771 29772
6 4,4 - 5,3 58,0
Part no. 29773 29774 29775 29776
10 5,7 - 6,8 96,0

Packing Barrel (with various capacity)


H05V-K barrel
Part no. 28948 28949 28950 28951
0,5 2,1 - 2,5 4,8
Part no. 28952 28953 28954 28955
0,75 2,2 - 2,7 7,2
Part no. 28956 28957 28958 28959
1 2,4 - 2,8 9,6

Packing Barrel (with various capacity)


(H)07V-K barrel
Part no. 28960 28961 28962 28963
1,5 2,8 - 3,4 14,4
Part no. 28964 28965 28966 28967
2,5 3,4 - 4,1 24,0
Part no. 28968 28969 28970 28971
4 3,9 - 4,8 38,0
Part no. 28972 28973 28974 28975
6 4,4 - 5,3 58,0
Part no. 28976 28977 28978 28979
10 5,7 - 6,8 96,0

Dimensions and specifications may be changed without prior notice.

293
Single Conductors

H05V-U / H07V-U PVC-single cores, single wire stranded


H05V-U
Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT o.col. o.col. o.col. o.col. o.col. o.col. o.col. o.col.
sec. min. - max. weight
mm mm kg / km
approx. RAL 9005 - 5015 8003 3000 9003 7001 4005 - - - - - - - -

Packing Coil in cardboard (100m)


H05V-U coil
Part no. 28761 28762 28763 28764 28765 28766 28767 28768 - - - - - - - -
0,5 1,9 - 2,3 4,8
Part no. 28769 28770 28771 28772 28773 28774 28775 28776 - - - - - - - -
0,75 2,1 - 2,5 7,2
Part no. 28777 28778 28779 28780 28781 28782 28783 28784 - - - - - - - -
1 2,2 - 2,7 9,6

Packing Spool (with various capacity)


H05V-U spool
Part no. 26937 26938 26939 26940 26941 26942 26943 26944 - - - - - - - -
0,5 1,9 - 2,3 4,8
Part no. 26945 26946 26947 26948 26949 26950 26951 26952 - - - - - - - -
0,75 2,1 - 2,5 7,2
Part no. 26953 26954 26955 26956 26957 26958 26959 26960 - - - - - - - -
1 2,2 - 2,7 9,6

Packing Coil in cardboard (100m)


H07V-U coil
Part no. 28785 28786 28787 28788 28789 28790 28791 28792 - - - - - - - -
1,5 2,6 - 3,2 14,4
Part no. 28793 28794 28795 28796 28797 28798 28799 28800 - - - - - - - -
2,5 3,2 - 3,9 24,0
Part no. 28801 28802 28803 28804 28805 28806 28807 28808 - - - - - - - -
4 3,6 - 4,4 38,0
Part no. 28809 28810 28811 28812 28813 28814 28815 28816 - - - - - - - -
6 4,1 - 5,0 58,0
Part no. 28817 28818 28819 28820 28821 28822 28823 28824 - - - - - - - -
10 5,3 - 6,4 96,0

Packing Drum
H07V-U drum
Part no. 28145 28146 28147 28148 28149 28150 28151 28152 - - - - - - - -
1,5 2,6 - 3,2 14,4
Part no. 28153 28154 28155 28156 28157 28158 28159 28160 - - - - - - - -
2,5 3,2 - 3,9 24,0
Part no. 28161 28162 28163 28164 28165 28166 28167 28168 - - - - - - - -
4 3,6 - 4,4 38,0
Part no. 28169 28170 28171 28172 28173 28174 28175 28176 - - - - - - - -
6 4,1 - 5,0 58,0
Part no. 28177 28178 28179 28180 28181 28182 28183 28184 - - - - - - - -
10 5,3 - 6,4 96,0

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

294
Single Conductors

H07V-R PVC-single cores, multi wire


H07V-R
Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT o.col. o.col. o.col. o.col. o.col. o.col. o.col. o.col.
sec. min. - max. weight
mm mm kg / km
approx. RAL 9005 - 5015 8003 3000 9003 7001 4005 - - - - - - - -

Packing Coil in foil


H07V-R coil
Part no. 28825 28826 28827 28828 28829 28830 28831 28832 - - - - - - - -
16 6,4 - 7,8 154,0
Part no. 28833 28834 28835 28836 28837 - - - - - - - - - - -
25 8,1 - 9,7 240,0
Part no. 28838 28839 28840 28841 28842 - - - - - - - - - - -
35 9,0 - 10,9 336,0
Part no. 28843 28844 28845 28846 28847 - - - - - - - - - - -
50 10,6 - 12,8 480,0
Part no. 28848 28849 28850 28851 28852 - - - - - - - - - - -
70 12,1 - 14,6 672,0
Part no. 28853 28854 28855 28856 28857 - - - - - - - - - - -
95 14,1 - 17,1 912,0
Part no. 28858 28859 28860 28861 28862 - - - - - - - - - - -
120 15,6 - 18,8 1152,0
Part no. 28863 28864 28865 28866 28867 - - - - - - - - - - -
150 17,3 - 20,9 1440,0
Part no. 28868 28869 28870 28871 28872 - - - - - - - - - - -
185 19,3 - 23,3 1776,0
Part no. 28873 28874 28875 28876 28877 - - - - - - - - - - -
240 22,0 - 26,6 2304,0

Packing Drum
H07V-R drum
Part no. 28185 28186 28187 28188 28189 28190 28191 28192 - - - - - - - -
16 6,4 - 7,8 154,0
Part no. 28193 28194 28195 28196 28197 - - - - - - - - - - -
25
Part no.
8,1 - 9,7 240,0
28198 28199 28200 28201 28202 - - - - - - - - - - -
K
35 9,0 - 10,9 336,0
Part no. 28203 28204 28205 28206 28207 - - - - - - - - - - -
50 10,6 - 12,8 480,0
Part no. 28208 28209 28210 28211 28212 - - - - - - - - - - -
70 12,1 - 14,6 672,0
Part no. 28213 28214 28215 28216 28217 - - - - - - - - - - -
95 14,1 - 17,1 912,0
Part no. 28218 28219 28220 28221 28222 - - - - - - - - - - -
120 15,6 - 18,8 1152,0
Part no. 28223 28224 28225 28226 28227 - - - - - - - - - - -
150 17,3 - 20,9 1440,0
Part no. 28228 28229 28230 28231 28232 - - - - - - - - - - -
185 19,3 - 23,3 1776,0
Part no. 28233 28234 28235 28236 28237 - - - - - - - - - - -
240 22,0 - 26,6 2304,0

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

295
H05V-K, H07V-K
PVC-Single Cores

= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Barrels, one-way barrels or barrels on hire


Type one-way cardboard ca. contents
cross section 8-on guar in m
2
mm dimension
in mm
LiY
0,25 500 x 500 x 420 10000
0,50 500 x 500 x 420 7000
0,75 500 x 500 x 420 5000
1,00 500 x 500 x 420 4000
1,50 500 x 500 x 420 3000

Type one-way barrels ca. contents


cross section 8-on guar in m
2
mm dimension
in mm
H05 V-K
H07 V-K
0,50 400 x 400 x 500 4000
0,75 400 x 400 x 500 3500
Delivery for one-way barrel Works photo: HELUKABEL
1,00 400 x 400 x 500 3000
1,50 400 x 400 x 500 2000
2,50 400 x 400 x 500 1200
4,00 400 x 400 x 500 900
6,00 400 x 400 x 500 800

Type one-way barrels ca. contents


cross section 8-on guar in m
2
mm dimension
in mm
H05 V-K
H07 V-K
0,50 400 x 400 x 800 7000
0,75 400 x 400 x 800 6000
1,00 400 x 400 x 800 5200
1,50 400 x 400 x 800 3500
2,50 400 x 400 x 800 2000

The materials used in manufacture are cadmium-free and


contain no silicone and free from substances harmful to
the wetting properties of lacquers

PVC self-extinguishing and flame retardant according


to DIN VDE 0482-332-1-2, DIN EN 60332-1-2/IEC 60332-1
(equivalent DIN VDE 0472 part 804 test method B)

K = Fine stranded conductor

296
Single Conductors

TOPFLEX 303 X07V-K-Y double insulation 0,6/1kV flexible PVC single core,
oil resistant

Technical data Cable structure Properties


Special PVC single-core cable with double Bare copper-conductor, to Largely resistant to oil, weather, and
insulation and oil-resistant sheath DIN VDE 0295 cl.5, fine-wire, chemicals; Chemical resistance (see
Temperature range BS 6360 cl.5, IEC 60228 cl.5 table Technical Information)
flexing -5C to +80C Core insualtion of special PVC Improved mechanical protection due the
fixed installation -40C to +80C Core identification BK or GN-YE double insulation
Nominal voltage U0/U 600/1000 V Outer sheath of special PVC Tests
A.C. test voltage, 50 Hz compound type TM5 to PVC self-extinguishing and flame retardant
3000 V DIN VDE 0207-363-4-1/ DIN EN 50363-4-1 acc. to DIN VDE 0482-332-1-2,
Insulation resistance Sheath colour grey DIN EN 60332-1-2, IEC 60332-1 (equivalent
min. 20 MOhm/km DIN VDE 0472 part 804 test method B)
Minimum bending radius
flexing 12x cable Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This cable is used for conditions of increased mechanical stress. For flexible use with free movement without tensile stress or forced movements in
dry, moist and wet environments, but not suitable for use outdoors. The cable may be laid in trays, troughs and channels.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
core-/sheath-color black/grey core-/sheath-color green-yellow/grey
K
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
75460 1x6 6,0 58,0 84,0 10 75449 1G6 6,0 57,6 84,0 10
75461 1 x 10 9,5 96,0 143,0 8 75469 1 G 10 9,5 96,0 143,0 8
75462 1 x 16 10,3 154,0 209,0 6 73859 1 G 16 10,3 154,0 209,0 6
75463 1 x 25 11,1 240,0 308,0 4 75470 1 G 25 11,1 240,0 325,0 4
75464 1 x 35 15,0 336,0 440,0 2 75471 1 G 35 15,0 336,0 440,0 2
75465 1 x 50 17,5 480,0 572,0 1 75472 1 G 50 17,5 480,0 572,0 1
75466 1 x 70 20,0 672,0 792,0 2/0 75473 1 G 70 20,0 672,0 792,0 2/0
75467 1 x 95 22,0 912,0 1155,0 3/0 75474 1 G 95 22,0 912,0 1155,0 3/0
72184 1 x 120 23,5 1152,0 1267,0 4/0 75475 1 G 120 23,5 1152,0 1267,0 4/0
72185 1 x 150 26,5 1440,0 1650,0 300 kcmil 75476 1 G 150 26,5 1440,0 1650,0 300 kcmil
75468 1 x 185 29,0 1776,0 2134,0 350 kcmil 75477 1 G 185 29,0 1776,0 2134,0 350 kcmil
74221 1 x 240 31,0 2304,0 2943,0 500 kcmil 75478 1 G 240 31,0 2304,0 2943,0 500 kcmil
72082 1 x 300 35,0 2880,0 3600,0 600 kcmil 75479 1 G 300 35,0 2280,0 3600,0 600 kcmil

Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

297
Single Conductors

LifY Single Core extra fine wires with highest flexibility

Technical data Cable structure Properties


Special plastic stranded wire Bare Cu-conductors, extra fine-wire The materials used in manufacture are
by special design extremly flexible conductor construction see table below cadmium-free and contain no silicone
adapted to DIN VDE 0250, Core insulation of PVC (soft, smooth) and free from substances harmful to
DIN VDE 0285-525-1 / DIN EN 50525-1 stranded specially the wetting properties of lacquers
Temperature range Tests
flexing -15C to +80C PVC self-extinguishing and flame retardant
Operating voltage acc. to DIN VDE 0482-332-1-2,
up to 0,25 mm 300 V DIN EN 60332-1-2/IEC 60332-1 (equivalent
(not for purposes of high current and DIN VDE 0472 part 804 test method B)
power installation)
Nominal voltage Note
0,5-1 mm U0/U 300/500 V Please complete the part number for
from 1,5 mm U0/U 450/750 V these cores by adding the suffix for
Test voltage the colour required as per the list:
up to 0,25 mm = 2 kV 00 = green, 01 = black, 02 = red,
0,5-1 mm = 2,5 kV 03 = blue, 04 = brown, 05 = white,
from 1,5 mm = 3 kV 06 = grey, 07 = violet, 08 = yellow,
Minimum bending radius 09 = orange, 10 = transparent,
flexing 8x core 11 = pink, 12 = beige, 13 = 2-colour
15= darkblue
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
The LifY single cores are used as super flexible insulated strand wires for switch cabinets, as measuring cable for testing, laboratories, research etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Core Cross- Cond. Outer Cop. Weight AWG-No. Part no. Core Cross- Cond. Outer Cop. Weight AWG-No.
colour sec. make-up approx. weight approx. colour sec. make-up approx. weight approx.
mm (nom. val.) mm kg / km kg / km mm (nom. val.) mm kg / km kg / km
n x wire n x wire
151xx - 0,1 51 x 0,05 1,0 1,2 2,1 - 15097 BK 35 4508 x 0,1 11,7 336,0 380,0 2
152xx - 0,14 72 x 0,05 1,0 1,4 2,6 26 15139 GN-YE 35 4508 x 0,1 11,7 336,0 380,0 2
153xx - 0,25 65 x 0,07 1,3 2,5 4,2 24 15127 BU 35 4508 x 0,1 11,7 336,0 380,0 2
154xx - 0,5 132 x 0,07 2,0 5,5 8,0 20 15128 BN 35 4508 x 0,1 11,7 336,0 380,0 2
155xx - 0,75 195 x 0,07 2,2 8,0 12,0 18 15126 RD 35 4508 x 0,1 11,7 336,0 380,0 2
156xx - 1 260 x 0,07 2,5 10,8 18,0 17 15098 BK 50 6468 x 0,1 14,7 480,0 521,0 1
157xx - 1,5 192 x 0,1 3,5 15,0 22,0 16 15140 GN-YE 50 6468 x 0,1 14,7 480,0 521,0 1
158xx - 2,5 320 x 0,1 3,8 25,0 37,0 14 15130 BU 50 6468 x 0,1 14,7 480,0 521,0 1
159xx - 4 512 x 0,1 4,9 40,0 50,0 12 15131 BN 50 6468 x 0,1 14,7 480,0 521,0 1
15093 BK 6 768 x 0,1 6,0 60,0 71,0 10 15129 RD 50 6468 x 0,1 14,7 480,0 521,0 1
15135 GN-YE 6 768 x 0,1 6,0 60,0 71,0 10 15099 BK 70 8967 x 0,1 15,5 672,0 740,0 2/0
15115 BU 6 768 x 0,1 6,0 60,0 71,0 10 15141 GN-YE 70 8967 x 0,1 15,5 672,0 740,0 2/0
15116 BN 6 768 x 0,1 6,0 60,0 71,0 10 15133 BU 70 8967 x 0,1 15,5 672,0 740,0 2/0
15114 RD 6 768 x 0,1 6,0 60,0 71,0 10 15134 BN 70 8967 x 0,1 15,5 672,0 740,0 2/0
15094 BK 10 1280 x 0,1 7,3 100,0 130,0 8 15132 RD 70 8967 x 0,1 15,5 672,0 740,0 2/0
15136 GN-YE 10 1280 x 0,1 7,3 100,0 130,0 8
15118 BU 10 1280 x 0,1 7,3 100,0 130,0 8
15119 BN 10 1280 x 0,1 7,3 100,0 130,0 8
15117 RD 10 1280 x 0,1 7,3 100,0 130,0 8
15095 BK 16 2048 x 0,1 8,8 160,0 187,0 6
15137 GN-YE 16 2048 x 0,1 8,8 160,0 187,0 6
15121 BU 16 2048 x 0,1 8,8 160,0 187,0 6
15122 BN 16 2048 x 0,1 8,8 160,0 187,0 6
15120 RD 16 2048 x 0,1 8,8 160,0 187,0 6
15096 BK 25 3234 x 0,1 10,5 240,0 294,0 4
15138 GN-YE 25 3234 x 0,1 10,5 240,0 294,0 4
15124 BU 25 3234 x 0,1 10,5 240,0 294,0 4
15125 BN 25 3234 x 0,1 10,5 240,0 294,0 4
15123 RD 25 3234 x 0,1 10,5 240,0 294,0 4

Dimensions and specifications may be changed without prior notice. (RK01)

298
Single Conductors

PUR Single Core cold resistant, halogen-free

Technical data Cable structure Properties


PUR-single cores, halogen-free Bare copper-conductor, to Halogen-free
Temperature range DIN VDE 0295 cl.5, fine-wire, Flexible at low temperatures up to -40C
-40C to +80C BS 6360 cl.5, IEC 60228 cl.5 Resistant against pressure
(up to +100C for short time) Core insulation of special PUR Overroll steady
Operating voltage 1000 V Core identification see table below Cut and scratchproof
Test voltage Resistant to
3500 V, 15 min. Oil
Minimum bending radius See and waste water
occasionally moved 10x core Acids
fixed installation 5x core Lye
Radiation resistance UV-radiation
up to 100x106 cJ/kg (up to 100 Mrad)

Application
PUR-single cores are suited for installation in switch cabinets, cable assemblies and electronic equipment. Inductive loops in the road surface for
controlling of light signalling equipment.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK TRANS D-BU OG BEIGE 2-col.

K
sec. approx. mm weight 9005 - 5015 8003 3000 1013 7000 4005 1021 3015 - 5010 2003 1001 -
mm kg / km
approx. RAL
Part no. 50651 50650 50652 50653 50654 50655 50656 50657 50658 50661 50660 50662 50659 50663 50664
0,5 2,2 4,8 - - - - - - - - - - - - - - -
Part no. 50666 50665 50667 50668 50669 50670 50671 50672 50673 50676 50675 50677 50674 50678 50679
0,75 2,4 7,2 - - - - - - - - - - - - - - -
Part no. 50681 50680 50682 50683 50684 50685 50686 50687 50688 50691 50690 50692 50689 50693 50694
1 2,5 9,6 - - - - - - - - - - - - - - -
Part no. 50696 50695 50697 50698 50699 50700 50701 50702 50703 50706 50705 50707 50704 50708 50709
1,5 3,0 14,4 - - - - - - - - - - - - - - -
Part no. 50711 50710 50712 50713 50714 50715 50716 50717 50718 50721 50720 50722 50719 50723 50724
2,5 3,7 24,0 - - - - - - - - - - - - - - -
Part no. 50726 50725 50727 50728 50729 50730 50731 50732 50733 50736 50735 50737 50734 50738 50739
4 4,3 38,0 - - - - - - - - - - - - - - -
Part no. 50741 50740 50742 50743 50744 50745 50746 50747 50748 50751 50750 50752 50749 50753 50754
6 5,1 58,0 - - - - - - - - - - - - - - -
Part no. 50756 50755 50757 50758 50759 50760 50761 50762 50763 50766 50765 50767 50764 50768 50769
10 6,8 96,0 - - - - - - - - - - - - - - -
Part no. 50771 50770 50772 50773 50774 50775 50776 50777 50778 50781 50780 50782 50779 50783 50784
16 7,8 154,0 - - - - - - - - - - - - - - -
Part no. 50786 50785 50787 50788 50789 50790 50791 50792 50793 50796 50795 50797 50794 50798 50799
25 10,0 240,0 - - - - - - - - - - - - - - -
Part no. 50801 50800 50802 50803 50804 50805 50806 50807 50808 50811 50810 50812 50809 50813 50814
35 11,4 336,0 - - - - - - - - - - - - - - -
Part no. 50816 50815 50817 50818 50819 50820 50821 50822 50823 50826 50825 50827 50824 50828 50829
50 13,2 480,0 - - - - - - - - - - - - - - -
Part no. 50831 50830 50832 50833 50834 50835 50836 50837 50838 50841 50840 50842 50839 50843 50844
70 15,4 672,0 - - - - - - - - - - - - - - -
Part no. 50846 50845 50847 50848 50849 50850 50851 50852 50853 50856 50855 50857 50854 50858 50859
95 17,7 912,0 - - - - - - - - - - - - - - -
Part no. 50861 50860 50862 50863 50864 50865 50866 50867 50868 50871 50870 50872 50869 50873 50874
120 19,2 1152,0 - - - - - - - - - - - - - - -
Part no. 50876 50875 50877 50878 50879 50880 50881 50882 50883 50886 50885 50887 50884 50888 50889
150 22,0 1440,0 - - - - - - - - - - - - - - -

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

299
Single Conductors

H05Z-K / H07Z-K single core, halogen-free

Technical data Cable structure Properties


Single cores for low emission of smoke Bare Cu-conductor, to The materials used in manufacture are
and corrosive gases in case of fire to DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN VDE 0285-525-3-41 / BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
DIN EN 50525-3-41 Separating foil over conductor permitted the wetting properties of lacquers
Conductor resistance Core insulation of cross-linked polyolefin Tests
acc. to DIN VDE 0295 cl.5 compound type EI5 to Behaviour in fire self-extinguishing and
Temperature range DIN VDE 0207-363-5 / DIN EN 50363-5 flame retardant to DIN VDE 0482-332-1-2,
-40C to +90C Core identification see table below DIN EN 60332-1-2,IEC 60332-1 (equivalent
Permissible working temperature LS0H= Low Smoke Zero Halogen DIN VDE 0472 part 804 test method B)
at conductor +90C Ozone resistant acc. to
Nominal voltage DIN VDE 0473-811-403,DIN EN 60811-403
H05Z-K = U0/U 300/500 V Smoke density acc. to DIN VDE 0482
H07Z-K = U0/U 450/750 V part 1034-1+2, DIN EN 61034-1+2,
Test voltage 2500 V IEC 61034-1+2, BS 7622 part 1+2
Insulation resistance at 90C (previously DIN VDE 0472 part 816)
to DIN VDE 0282 part 9 Halogen-free acc. to
Minimum bending radius DIN VDE 0285-525-1,DIN EN 50525-1
fixed installation appendix B
core 8 mm: 4x core
core > 8-12 mm: 5x core Note
core > 12 mm: 6x core Type H07Z-K
Radiation resistance Colour yellow only as (H)07Z-K available
up to 20x106 cJ/kg (up to 20 Mrad)

Application
Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets are to
protected from further damage resulting from fire. These types are suitable for laying in tubes on and under plaster, as well as in closed installation
ducts.
H07Z-K, suitable for protected, permanent laying in or on lighting installations or switching and control equipment up to 1000 V AC or 750 V DC to
earth.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05Z-K
Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE D-BU OG U-BU
sec. min. - max. weight approx.
mm mm kg / km kg / km
Part no. 52872 52873 52874 52875 52876 52877 52878 52879 52880 52945 52946 53071
0,5 2,1 - 2,6 4,8 9,0 - - - - - - - - - - - -
Part no. 52881 52882 52883 52884 52885 52886 52887 52888 52889 52947 52948 53072
0,75 2,2 - 2,8 7,2 12,4 - - - - - - - - - - - -
Part no. 52890 52891 52892 52893 52894 52895 52896 52897 52898 52949 52950 53073
1 2,4 - 2,9 9,6 15,0 - - - - - - - - - - - -

H07Z-K
Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE D-BU OG U-BU
sec. min. - max. weight approx.
mm mm kg / km kg / km
Part no. 51768 51769 51770 51771 51772 51773 51774 51775 51776 52951 52952 53074
1,5 2,8 - 3,5 14,4 24,0 - - - - - - - - - - - -
Part no. 51777 51778 51779 51780 51781 51782 51783 51784 51785 52953 52954 53075
2,5 3,4 - 4,3 24,0 35,0 - - - - - - - - - - - -
Part no. 51786 51787 51788 51789 51790 51791 51792 51793 51794 52955 52956 53076
4 3,9 - 4,9 38,0 51,0 - - - - - - - - - - - -
Part no. 51795 51796 51797 51798 51799 51800 51801 51802 51803 52957 52958 53077
6 4,4 - 5,5 58,0 71,0 - - - - - - - - - - - -
Part no. 51804 51805 51806 51807 51808 51809 51810 51811 51812 52959 52960 53078
10 5,7 - 7,1 96,0 118,0 - - - - - - - - - - - -
Part no. 51813 51814 51815 51816 51817 51818 51819 51820 51821 52961 52962 53079
16 6,7 - 8,4 154,0 180,0 - - - - - - - - - - - -
Part no. 51822 51823 51824 51825 51826 51827 51828 51829 51830 52963 52964 53080
25 8,4 - 10,6 240,0 278,0 - - - - - - - - - - - -
Part no. 51831 51832 51833 51834 51835 51836 51837 51838 51839 52965 52966 53081
35 9,7 - 12,1 336,0 375,0 - - - - - - - - - - - -
Part no. 51840 51841 51842 51843 51844 51845 51846 51847 51848 52967 52968 53082
50 11,5 - 14,4 480,0 560,0 - - - - - - - - - - - -

Continuation

300
Single Conductors

H05Z-K / H07Z-K single core, halogen-free


H07Z-K
Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE D-BU OG U-BU
sec. min. - max. weight approx.
mm mm kg / km kg / km
Part no. 51849 51850 51851 51852 51853 51854 51855 51856 51857 52969 52970 53083
70 13,2 - 16,6 672,0 780,0 - - - - - - - - - - - -
Part no. 51858 51859 51860 51861 51862 51863 51864 51865 51866 52971 52972 53084
95 15,1 - 18,8 912,0 952,0 - - - - - - - - - - - -
Part no. 51867 51868 51869 51870 51871 51872 51873 51874 51875 52973 52974 53085
120 16,7 - 20,9 1152,0 1200,0 - - - - - - - - - - - -
Part no. 51876 51877 51878 51879 51880 51881 51882 51883 51884 52975 52976 53086
150 18,6 - 23,3 1440,0 1505,0 - - - - - - - - - - - -
Part no. 51885 51886 51887 51888 51889 51890 51891 51892 51893 52977 52978 53087
185 20,6 - 25,8 1776,0 1845,0 - - - - - - - - - - - -
Part no. 51894 51895 51896 51897 51898 51899 51900 51901 51902 52979 52980 53088
240 23,5 - 29,4 2304,0 2400,0 - - - - - - - - - - - -

H05Z-K two colour, coil in foil


Cross- Outer Cop. Weight RD/WH BU/WH BN/WH D-BU/WH
sec. min. - max. weight
mm mm kg / km
Part no. 51392 51393 51394 51395
0,5 2,1 - 2,6 4,8 9,0
Part no. 51396 51397 51398 51399
0,75 2,2 - 2,8 7,2 12,4
Part no. 51400 51401 51402 51403
1 2,2 - 2,8 9,6 15,0

H07Z-K two colour, coil in foil


Cross- Outer Cop. Weight RD/WH BU/WH BN/WH D-BU/WH
sec. min. - max. weight
mm mm kg / km
Part no. 51404 51405 51406 51407
1,5 2,8 - 3,5 14,4 24,0
Part no. 51408 51409 51410 51411
2,5 3,4 - 4,3 24,0 35,0
Part no. 51412 51413 51414 51415
4 3,9 - 4,9 38,0 51,0
Part no. 51416 51417 51418 50899
6 4,4 - 5,5 58,0 71,0

H05Z-K, barrel (with various capacity)


Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE D-BU OG U-BU
sec. min. - max. weight approx.
mm
Part no.
0,5
mm

2,1 - 2,6
kg / km

4,8
kg / km

9,0
52809
-
52810
-
52811
-
52812
-
52813
-
52814
-
52815
-
52816
-
-
-
52817
-
52819
-
-
-
K
Part no. 52821 52822 52823 52824 52825 52826 52827 52828 - 52829 52831 -
0,75 2,2 - 2,8 7,2 12,4 - - - - - - - - - - - -
Part no. 52833 52834 52835 52836 52837 52838 52839 52840 - 52841 52843 -
1 2,4 - 2,9 9,6 15,0 - - - - - - - - - - - -

H07Z-K, barrel (with various capacity)


Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE D-BU OG U-BU
sec. min. - max. weight approx.
mm mm kg / km kg / km
Part no. 52845 52846 52847 52848 52849 52850 52851 52852 - 52853 52855 -
1,5 2,8 - 3,5 14,4 24,0 - - - - - - - - - - - -
Part no. 52857 52858 52859 52860 52861 52862 52863 52864 - 52865 52867 -
2,5 3,4 - 4,3 24,0 35,0 - - - - - - - - - - - -
Part no. 52135 52136 52137 52138 52139 52140 52141 52142 - 52143 52144 -
4 3,9 - 4,9 38,0 51,0 - - - - - - - - - - - -
Part no. 52145 52146 52147 52148 52149 52150 52151 52152 - 52153 52154 -
6 4,4 - 5,5 58,0 71,0 - - - - - - - - - - - -

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

301
Single Conductors

H05G-U / -K / H07G-U / -R / -K

Technical data Cable structure Properties


Heat-resistant (+110C) Tinned Cu-conductor, to Single core colours green and yellow can
rubber-insulated cable to DIN VDE 0295, IEC 60228, BS 6360 only be applied where the safety
DIN VDE 0285-525-2-42/ class 1: single-wire regulations are allowed
DIN EN 50525-2-42 class 2: multi-wire The identification for the lighting chain
Max. permissible operating class 5: fine-wire cable is green permitted
temperature Separating foil over conductor permitted
at conductor +110C Core insulation of rubber Note
Lowest ambient temperatures compound type EI3 (EVA) to Please complete the part number for
flexing up to -25C DIN VDE 0207-363-1 / DIN EN 50363-1 these cores by adding the suffix for
fixed installation up to -40C the colour required as per the list:
Nominal voltage 00 = green
H05G = U0/U 300/500 V 01 = black
H07G = U0/U 450/750 V 02 = blue
Test voltage 03 = brown
H05G = 2000 V 04 = grey
H05G = 2500 V 05 = orange
Minimum bending radius 06 = pink
fixed installation 07 = turquoise
core 8 mm: 4x core 08 = white
core > 8-12 mm: 5x core 09 = violet
core > 12 mm: 6x core 10 = yellow
11 = green-yellow
bare conductor on request
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
For inside wiring of switch boards and distributors as well as of operating parts such as in or on lights, for the connection of electric heaters with a
nominal voltage up to 1000 V alternating voltage or up to 750 V direct voltage against ground. These single cores are all allowed for laying in tubes,
on and under plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05G-U (single wire) H07G-U (single wire)
Part no. Cross- Outer Cop. Weight AWG-No. Part no. Cross- Outer Cop. Weight AWG-No.
section min. - max. weight approx. section min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
541xx 0,5 1,9 - 2,4 4,8 10,0 20 544xx 1,5 2,8 - 3,5 14,4 24,0 16
542xx 0,75 2,1 - 2,6 7,2 15,0 18 545xx 2,5 3,4 - 4,3 24,0 35,0 14
543xx 1 2,2 - 2,8 9,6 16,0 17 546xx 4 4,0 - 5,0 38,0 53,0 12

H05G-K (fine wire) H07G-K (fine wire)


Part no. Cross- Outer Cop. Weight AWG-No. Part no. Cross- Outer Cop. Weight AWG-No.
section min. - max. weight approx. section min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
550xx 0,5 2,1 - 2,6 4,8 13,0 20 553xx 1,5 3,0 - 3,7 14,4 24,0 16
551xx 0,75 2,2 - 2,8 7,2 16,0 18 554xx 2,5 3,6 - 4,5 24,0 42,0 14
552xx 1 2,4 - 2,9 9,6 22,0 17 555xx 4 4,3 - 5,4 38,0 61,0 12
556xx 6 4,8 - 6,0 58,0 78,0 10
557xx 10 6,0 - 7,6 96,0 130,0 8
558xx 16 7,1 - 8,9 154,0 212,0 6
559xx 25 8,8 - 11,0 240,0 323,0 4
560xx 35 10,1 - 12,6 336,0 422,0 2
561xx 50 11,9 - 14,9 480,0 527,0 1
562xx 70 13,6 - 17,0 672,0 726,0 2/0
563xx 95 15,5 - 19,3 912,0 937,0 3/0
564xx 120 17,1 - 21,4 1152,0 1192,0 4/0

H07G-R (multi wire)


Part no. Cross- Outer Cop. Weight AWG-No.
section min. - max. weight approx.
mm mm kg / km kg / km
547xx 6 4,7 - 5,9 58,0 72,0 10
548xx 10 6,0 - 7,4 96,0 123,0 8
549xx 16 6,8 - 8,5 154,0 184,0 6

Dimensions and specifications may be changed without prior notice. (RK01)

302
Single Conductors

LiYW / H05V2-K PVC-Single Cores, 90C, heat-resistant

Technical data Cable structure Properties


Special PVC single core with increased Bare copper-conductor, from 0,5 mm to The materials used in manufacture are
heat-resistance DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
LiYW up to 105C adapted to BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
DIN VDE 0285-525-1/DIN EN 50525-1 Wire make-up for: the wetting properties of lacquers
H05V2-K to 90C acc. to 0,14 mm = 18x0,1 mm Heat-resistant special PVC compound of
DIN VDE 0285-525-2-31/ 0,25 mm = 14x0,15 mm selected stabilizer and plasticizer
DIN EN 50525-2-31 LiYW special core insulation up to +105C Not to be used in contact with objects
Temperature range heat-resistant, adapted higher than 85C
LiYW to DIN VDE 0207 Tests
flexing +5C to +105C H05V2-K core insulation up to +90C All requirements and test methods
fixed installation -10C to +105C heat-resistant, compound type TI3 to conform DIN VDE 0285-525-2-31,
H05V2-K DIN VDE 0207-363-3 / DIN EN 50363-3 DIN EN 50525-2-31, deviates
flexing +5C to + 90C Core identification see table below however the maximal permissible operating
max. Temperatur at conductor temperature up to +105C for LiYW
under permanent load +90C PVC self-extinguishing and flame retardant
Nominal voltage acc. to DIN VDE 0482-332-1-2,
LiYW U0/U 300/500 V DIN EN 60332-1-2, IEC 60332-1 (equivalent
H05V2-K U0/U 300/500 V DIN VDE 0472 part 804 test method B)
Test voltage 2000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
K
fixed installation 4x core
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
Therm insulated wires are ideal for use in power current installation, switch cabinets, motors and transformers which are subject to direct contact with
high temperatures (e. g. varnishing machines and drying towers etc.). These are also suitable for inside wiring of electrical equipments such as lighting
and heating apparatus.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
LiYW 105C
Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT D-BU
section mm weight approx.
mm kg / km kg / km
Part no. 29500 29501 29502 29503 29504 29505 29506 29507 29508
0,14 1,3 1,4 3,2 - - - - - - - - -
Part no. 29509 29510 29511 29512 29513 29514 29515 29516 29517
0,25 1,8 2,4 4,3 - - - - - - - - -
Part no. 29518 29519 29520 29521 29522 29523 29524 29525 29526
0,5 2,6 4,8 7,2 - - - - - - - - -

H05V2-K 90C
Cross- Outer Cop. Weight AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No.
section min. - max. weight approx. BK GN-YE BU BN RD WH GY VT D-BU
mm mm kg / km kg / km
Part no. 29942 29943 29944 29945 29946 29947 29948 29949 29950
0,5 2,1 - 2,5 4,8 8,7 20 20 20 20 20 20 20 20 20
Part no. 29951 29952 29953 29954 29955 29956 29957 29958 29959
0,75 2,2 - 2,7 7,2 11,9 18 18 18 18 18 18 18 18 18
Part no. 29960 29961 29962 29963 29964 29965 29966 29967 29968
1 2,4 - 2,8 9,6 14,0 17 17 17 17 17 17 17 17 17

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

303
Single Conductors

H07V2-K PVC single core, 90C, heat resistant

Technical data Cable structure Properties


Special PVC single core with increased Bare copper-conductor, to Heat-resistant special PVC
heat-resistance up to 90C acc. to DIN VDE 0295 cl.5, fine-wire, compound of selected stabilizer
DIN VDE 0285-525-2-31/ BS 6360 cl.5, IEC 60228 cl.5 and plasticizer
DIN EN 50525-2-31 Core insulation of heat-resistant PVC Not to be used in contact with objects
Temperature range compound type TI3 to higher than 85C
flexing +5C to +90C DIN VDE 0207-363-3/DIN EN 50363-3 The materials used in manufacture are
max. Temperature at conductor Core identification see table below cadmium-free and contain no silicone
under permanent load: +90C and free from substances harmful to
Nominal voltage U0/U 450/750 V the wetting properties of lacquers
Test voltage 2000 V Tests
Insulation resistance PVC self-extinguishing and flame retardant
min. 20 MOhm x km acc. to DIN VDE 0482-332-1-2,
Minimum bending radius DIN EN 60332-1-2/IEC 60332-1 (equivalent
10-15x core DIN VDE 0472 part 804 test method B)
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
Therm insulated wires are ideal for use in power current installation, switch cabinets, motors and transformers which are subject to direct contact with
high temperatures (e. g. varnishing machines and drying towers etc.). These are also suitable for inside wiring of electrical equipments such as lighting
and heating apparatus. Suitable for fixed protected installation in, or on lighting or controlgear for voltages up to 1000 V a.c. or, up to 750 V d.c. to
earth.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT D-BU


section min. - max. weight approx.
mm mm kg / km kg / km
Part no. 29970 29971 29972 29973 29974 29975 29976 29977 29978
1,5 2,8 - 3,4 14,4 20,0 - - - - - - - - -
Part no. 29979 29980 29981 29982 29983 29984 29985 29986 29987
2,5 3,4 - 4,1 24,0 33,3 - - - - - - - - -
Part no. 29988 29989 29990 29991 29992 29993 29994 29995 29996
4 3,9 - 4,8 38,0 48,3 - - - - - - - - -
Part no. 29997 29998 29999 30000 30001 30002 30003 30004 30005
6 4,4 - 5,3 58,0 68,5 - - - - - - - - -
Part no. 30006 30007 30008 30009 30010 30011 30012 30013 30014
10 5,7 - 6,8 96,0 115,0 - - - - - - - - -
Part no. 30015 30016 30017 30018 30019 30020 30021 30022 30023
16 6,7 - 8,1 154,0 170,0 - - - - - - - - -
Part no. 30024 30025 30026 30027 30028 30029 30030 30031 30032
25 8,4 - 10,2 240,0 270,0 - - - - - - - - -
Part no. 30033 30034 30035 30036 30037 30038 30039 30040 30041
35 9,7 - 11,7 336,0 367,0 - - - - - - - - -

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

304
Single Conductors

HELUTHERM 145 flexible, cross-linked, halogen-free

Technical data Cable structure Properties


Halogen-free single cores with increased Tinned copper-conductor, to Lower propagation of fire
heat resistance DIN VDE 0295 cl.5, fine-wire, Low development of smoke and fumes
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Good abrasion and notch resistance
flexing -35C to +120C Core insulation of polyolefin-copolymer Good resistance to oils and weathering
fixed installation -55C to +145C cross-linked and halogen-free Resistant to UV radiation and ozone
Nominal voltage Core identification see table below Resistant to soldering temperatures
up to 1 mm = U0/U 300/500 V Tests Thermal class B
from 1,5 mm = U0/U 450/ 750 V Flame test (unit flame test) acc. to These single-core cables are resistant to
at fixed and protected installation DIN VDE 0482-332-3-22, BS 4066 Teil 3, melting, even when in contact with a
from 1,5 mm = U0/U 600/1000 V DIN EN 60332-3-22, IEC 60332-3-22 soldering iron at temperatures of between
Test voltage 3500 V (previously DIN VDE 0472 300C and 380C, because of the
Minimum bending radius part 804 test method C) cross-linking for the insulation material
flexing 12,5x core Flame test (cable) acc. to Due to the high temperature profile the
fixed installation 4x core DIN VDE 0482-332-1-2, DIN EN 60332-1-2, cross-section of conductor can under certain
Caloric load values IEC 60332-1-2 (equivalent DIN VDE 0472 circumstances be reduced, hereby enabling
see Technical Informations part 804 test method B) a saving in space requirement and weight
Approval Corrosiveness of combustion gases The materials used in manufacture are
Germanischer Lloyd acc. to DIN VDE 0482 part 267, cadmium-free and contain no silicone
DIN EN 50267-2-2, IEC 60754-2 and free from substances harmful to
(equivalent DIN VDE 0472 part 813) the wetting properties of lacquers
Halogen-free acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-1, IEC 60754-1
K
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Application
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systems
and distributors in equipment and plant and machinery, suitable for laying in tubes on and under plaster, in closed installation ducts, as well as for
traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks. For a protected installation, these
cables may be used at a nominal voltage of up to 1000 V alternating current or a direct current up to 750 V when earthed. The maximum operating
d. c. voltage used in rail vehicles shall not exceed 900 V when earthed. These halogen-free single core cables are characterised by their amazingly
high long-time resistance to temperature and feature among the leading halogen-free, flame resistant products in the world. These single core cables
significantly contribute to safety and the environment.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE GN D-BU OG BEIGE 2-col.


sec. approx. weight approx.
mm mm kg / km kg / km
Part no. 50999 50998 51070 51071 51072 51073 51074 51075 51076 51078 51079 51077 51164 51165
0,25 1,6 2,4 4,0
Part no. 51167 51166 51168 51169 51170 51171 51172 51173 51174 51176 51177 51175 51178 51179
0,34 1,7 3,2 5,0
Part no. 51281 51280 51282 51283 51284 51285 51286 51287 51288 51290 51291 51289 51292 51293
0,5 1,9 4,8 7,0
Part no. 51295 51294 51296 51297 51298 51299 51300 51301 51302 51304 51305 51303 51306 51307
0,75 2,2 7,2 11,0
Part no. 51309 51308 51310 51311 51312 51313 51314 51315 51316 51318 51319 51317 51320 51321
1 2,5 9,6 14,0
Part no. 51323 51322 51324 51325 51326 51327 51328 51329 51330 51332 51333 51331 51334 51335
1,5 2,9 14,4 20,0
Part no. 51337 51336 51338 51339 51340 51341 51342 51343 51344 51346 51347 51345 51348 51349
2,5 3,5 24,0 30,0
Part no. 51351 51350 51352 51353 51354 51355 51356 51357 51358 51360 51361 51359 51362 51363
4 4,3 38,0 47,0
Part no. 51365 51364 51366 51367 51368 51369 51370 51371 51372 51374 51375 51373 51376 51377
6 5,0 58,0 72,0
Part no. 51379 51378 51380 51381 51382 51383 51384 51385 51386 51388 51389 51387 51390 51391
10 6,3 96,0 120,0

Continuation

305
Single Conductors

HELUTHERM 145 flexible, cross-linked, halogen-free

Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE GN D-BU OG BEIGE 2-col.


sec. approx. weight approx.
mm mm kg / km kg / km
Part no. 51420 51419 51421 51422 51423 51424 51425 51426 51427 51429 51430 51428 51431 51432
16 7,3 154,0 182,0
Part no. 51434 51433 51435 51436 51437 51438 51439 51440 51441 51443 51444 51442 51445 51446
25 9,6 240,0 272,0
Part no. 51448 51447 51449 51450 51451 51452 51453 51454 51455 51457 51458 51456 51459 51460
35 10,8 336,0 371,0
Part no. 51462 51461 51463 51464 51465 51466 51467 51468 51469 51471 51472 51470 51473 51474
50 12,6 480,0 530,0
Part no. 51476 51475 51477 51478 51479 51480 51481 51482 51483 51485 51486 51484 51487 51488
70 14,6 672,0 730,0
Part no. 51490 51489 51491 51492 51493 51494 51495 51496 51497 51499 51500 51498 51501 51502
95 16,5 912,0 964,0
Part no. 51504 51503 51505 51506 51507 51508 51509 51510 51511 51513 51514 51512 51515 51516
120 18,0 1152,0 1235,0
Part no. 51518 51517 51519 51520 51521 51522 51523 51524 51525 51527 51528 51526 51529 51530
150 20,0 1440,0 1523,0
Part no. 51532 51531 51533 51534 51535 51536 51537 51538 51539 51541 51542 51540 51543 51544
185 22,2 1776,0 1850,0
Part no. 51546 51545 51547 51548 51549 51550 51551 51552 51553 51555 51556 51554 51557 51558
240 24,5 2304,0 2432,0

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

306
Single Conductors

SiF / SiFF silicon single cores, halogen-free

Technical data Cable structure Properties


Spezial-silicon single core with higher Type SiF Resistant to
heat-resistance range adapted to Tinned copper-conductor,from 0,5 mm to high molecular oils, fats from vegetables and
DIN VDE 0250 Teil 1 and part 502 DIN VDE 0295 cl.5, fine-wire, animals, alcohols, plasticizers and clophenes,
Temperatue range BS 6360 cl.5, IEC 60228 cl.5 diluted acids, lyes and salt dissolution,
-60C to +180C Conductor construction oxidation substances, tropical influences and
(up to +220C for short time) 0,25 mm = 14x0,15 mm weather, lake water, oxygen
Temperature limit at the conductor Core insulation of silicone High flash points
in operation +180C Type SiFF For laying as a fixed installation only in open
Nominal voltage U0/U 300/500 V Tinned Cu-conductor, to or ventilated pipe systems as well as in
Test voltage 2000 V DIN VDE 0295 cl.6, extra fine-wire, ducts. Otherwise the mechanical properties
Breakdown voltage min. 5000 V BS 6360 cl.6, IEC 60228 cl.6 of the silicon are reduced by the enclosed
Minimum bending radius (single wire 0,07 mm) air at temperatures exceeding 90C.
6x core Core insulation of silicone Tests
Radiation resistance Corrosiveness of combustion gases
up to 20 x 106 cJ/kg (up to 20 Mrad) (Halogen-free) acc. to DIN VDE 0482
part 267, DIN EN 50267-2-2,
IEC 60754-2 (equivalent
DIN VDE 0472 part 813)
Behaviour in fire no flame propagation
acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2,IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
K
Note
Please complete the part number for these
cables by adding the suffix for the colour
required as per the list:
00 = green, 01 = black, 02 = red,
03 = blue, 04 = brown, 05 = white,
06 = grey, 07 = violet, 08 = yellow,
09 = orange, 10 = transparent,
11 = pink, 12 = beige, 13 = 2-colour
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Special single cores for use in high, resp. low temperature areas. They are used mainly in the steel producing industries, in aviation industries as well
as in ship building, cement, glas and ceramic factories. As this single cores are halogen-free, especially suited for use in power stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
SiF SiFF
Part no. Cross- Outer Cop. Weight AWG-No. Part no. Cross- Outer Cop. Weight AWG-No.
section approx. mm weight approx. section approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
232xx 0,25 1,9 2,4 5,5 24 451xx 0,25 1,9 2,4 6,0 24
233xx 0,5 2,1 4,8 8,6 20 452xx 0,5 2,2 4,8 10,0 20
234xx 0,75 2,4 7,2 11,8 18 453xx 0,75 2,5 7,2 13,0 18
235xx 1 2,5 9,6 13,5 17 454xx 1 2,6 9,6 15,0 17
236xx 1,5 2,8 14,4 18,5 16 455xx 1,5 3,1 14,4 19,0 16
237xx 2,5 3,4 24,0 30,0 14 456xx 2,5 3,7 24,0 32,0 14
238xx 4 4,2 38,0 47,3 12 457xx 4 4,4 38,0 50,0 12
239xx 6 5,0 58,0 71,1 10 458xx 6 5,2 58,0 73,0 10
246xx 10 6,6 96,0 119,4 8 459xx 10 6,8 96,0 125,0 8
247xx 16 7,4 154,0 187,7 6
248xx 25 9,2 240,0 289,6 4

SiF (wire colour black)


Part no. Cross- Outer Cop. Weight AWG-No.
section approx. mm weight approx.
mm kg / km kg / km
23953 35 10,3 336,0 398,3 2
23954 50 11,8 480,0 559,7 1
23955 70 13,6 672,0 765,8 2/0
23956 95 15,6 912,0 1031,5 3/0
23957 120 17,6 1152,0 1284,6 4/0
23958 150 19,6 1440,0 1563,4 300 kcmil
23959 185 22,4 1776,0 1858,2 350 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

307
Single Conductors

SiF/GL, SiD, SiD/GL silicon single cores, halogen-free

Technical data Cable structure Properties


Spezial-silicon single core with higher Type SiF/GL Resistant to
heat-resistance range adapted to Tinned copper-conductor, from 0,5 mm to high molecular oils, fats from vegetables
DIN VDE 0250 Teil 1 and part 502 DIN VDE 0295 cl.5, fine-wire, and animals, alcohols, plasticizers and
Temperatue range BS 6360 cl.5, IEC 60228 cl.5 clophenes, diluted acids, lyes and salt
-60C to +180C Conductor construction: dissolution, oxidation substances, tropical
(for short time +220C) 0,25 mm = 14x0,15 mm influences and weather, lake water, oxygen
Temperature limit at the conductor Core insulation of silicone High flash points
in operation +180C Glass-fibre braiding For laying as a fixed installation only in open
Nominal voltage U0/U 300/500 V Type SiD or ventilated pipe systems as well as in
Test voltage 2000 V Tinned copper-conductor, single-wire ducts. Otherwise the mechanical properties
Breakdown voltage min. 5000 V Core insulation of silicone of the silicon are reduced by the enclosed
Minimum bending radius Type SiD/GL air at temperatures exceeding 90C.
15x core Tinned copper-conductor, single-wire Tests
(SID only for permanent installation) Core insulation of silicone Corrosiveness of combustion gases
Radiation resistance Glass-fibre braiding (Halogen-free) acc. to DIN VDE 0482
up to 20 x 106 cJ/kg (up to 20 Mrad) part 267, DIN EN 50267-2-2,
IEC 60754-2 (equivalent
DIN VDE 0472 part 813)
Behaviour in fire no flame propagation
acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2,IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)

Note
Please complete the part number for these
cables by adding the suffix for the colour
required as per the list:
00 = green, 01 = black, 02 = red,
03 = blue, 04 = brown, 05 = white,
06 = grey, 07 = violet, 08 = yellow,
09 = orange, 10 = transparent,
11 = pink, 12 = beige, 13 = 2-colour
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Special single cores for use in high, resp. low temperature areas. They are used mainly in the steel producing industries, in aviation industries as well
as in ship building, cement, glas and ceramic factories. As this single cores are halogen-free, especially suited for use in power stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
SiF/GL SiD
Part no. Cross- Outer Cop. Weight AWG-No. Part no. Cross- Outer Cop. Weight AWG-No.
section approx. mm weight approx. section approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
47001 0,25 2,4 2,4 7,7 24 461xx 0,2 1,7 1,9 4,2 -
47002 0,5 2,5 4,8 12,4 20 462xx 0,28 1,8 2,7 5,1 -
47003 0,75 2,8 7,2 16,2 18 463xx 0,5 2,0 4,8 7,5 20
47004 1 2,9 9,6 18,2 17 464xx 0,75 2,1 7,2 10,2 18
47005 1,5 3,2 14,4 23,4 16 465xx 1 2,3 9,6 12,6 17
47006 2,5 3,8 24,0 35,2 14 466xx 1,5 2,5 14,4 18,1 16
47007 4 4,6 38,0 53,5 12 467xx 2,5 3,2 24,0 28,7 14
47008 6 5,4 58,0 77,4 10 468xx 4 3,9 38,0 45,2 12
47009 10 7,6 96,0 129,2 8 469xx 6 4,4 58,0 64,3 10
47010 16 8,4 154,0 198,4 6
47011 25 10,2 240,0 303,0 4 SiD/GL
47012 35 11,3 336,0 413,2 2 Part no. Cross- Outer Cop. Weight AWG-No.
47013 50 13,4 480,0 577,8 1 section approx. mm weight approx.
mm kg / km kg / km
47014 0,5 2,4 4,8 10,0 20
47015 0,75 2,6 7,2 15,0 18
47016 1 2,7 9,6 19,0 17
47017 1,5 3,0 14,4 28,0 16
47018 2,5 3,6 24,0 40,0 14
47019 4 4,3 36,0 55,0 12
47020 6 5,0 58,0 80,0 10

Dimensions and specifications may be changed without prior notice. (RK01)

308
Single Conductors

FZ-LSi / FZ-LS / Neon Light Cables

Technical data Cable structure Properties


FZ-LSi, blue FZ-LSi, blue Neon-light-cable, yellow
Test voltage 20 kV Tinned copper-conductor Halogen-free
Breakdown voltage min. 30 kV Conductor consturction see table below acc. to DIN VDE 0482 part 267,
Ignition voltage (kV eff.) Core insulation of silicone DIN EN 50267-2-2, IEC 60754-2
0,5 mm = 6 kV compound type 2GI1 to (equivalent DIN VDE 0472 part 813)
1,0 mm = 8 kV DIN VDE 0207 part 20 Behaviour in fire no flame propagation
1,5 mm = 10 kV Glass-fibre braiding acc. to DIN VDE 0482-332-1-2,
FZ-LS, red Outer sheath of silicone DIN EN 60332-1-2,IEC 60332-1 (equivalent
Test voltage compound type 2GM1 to DIN VDE 0472 part 804 test method B)
for 5 mm = 15 kV DIN VDE 0207 part 21 No formation of corrosive gases
for 7 mm = 20 kV Sheath colour blue Low smoke density
Breakdown voltage FZ-LS, red Very good weather resistance
for 5 mm = min. 25 kV Tinned copper-conductor, 19x0,25 mm
for 7 mm = min. 35 kV Core insulation of silicone Note
Neon-light-Cable, yellow compound type 2GI1 to AWG sizes are approximate equivalent
Nominal voltage DIN VDE 0207 part 20 values. The actual cross-section is in mm.
3,5 kV, 4,0 kV or 7,5 kV Sheath colour redbrown
Test voltage 10 kV Neon-light-cable, yellow
Specific volume resistivity in adapted to DIN VDE 0250 part 1+5
min. 1012 Ohm x cm Tinned copper-conductor, 30x0,25 mm
Minimum bending radius Core insulation of silicone K
7,5x cable compound type 2GI1 to
Radiation resistance DIN VDE 0207 part 20
up to 20x106 cJ/kg (up to 20 Mrad) Sheath colour yellow

Application
FZ-LSi, blue
This ignition cable is suitable for use at high and extremely alternating ambient temperatures up to +180C. Applications include engine manufacturing,
valve manufacturing and heating technology. As protection against mechanical damages a glass fibre braiding and a silicone sheath covers the core
insulation.
FZ-LS, red
This ignition cable is suitable for use at high and extremely alternating ambient temperatures up to +180C. Applications include the lamp and lighting
industry and cooling and airconditioning technology.
Neon-light-cable, yellow
This cable is primarily suitable for use at high and extremely alternating ambient temperatures such as in the lamp and lighting industry. Protected
installation is required.
FZ-LSi ignition cable FZ-LS high-voltage ignition cable 15 and 20kV
Part no. Core Cross- Cond. Outer Cop. Weight AWG-No. Part no. Core Cross- Cond. Outer Cop. Weight AWG-No.
colour sec. make-up approx. weight approx. colour sec. make-up approx. weight approx.
mm (nom. val.) mm kg / km kg / km mm (nom. val.) mm kg / km kg / km
n x wire n x wire
23110 BU 0,5 7 x 0,3 5,0 4,8 36,0 20 23109 red-brown 1 19 x 0,25 5,0 9,6 34,0 17
23106 BU 1 19 x 0,25 7,5 9,5 65,0 17 23108 red-brown 1 19 x 0,25 7,0 9,6 60,0 17
23107 BU 1,5 28 x 0,26 8,5 14,4 88,0 16
neon light cables (neon cable) 3,5kV, 4,0kV and 7,5kV
Part no. Core Cross- Cond. Outer Cop. Weight AWG-No.
colour sec. make-up approx. weight approx.
mm (nom. val.) mm kg / km kg / km
n x wire
23147 YE 1,5 30 x 0,25 4,4 14,4 32,0 16
23148 YE 1,5 30 x 0,25 6,6 14,4 59,0 16
23149 YE 1,5 30 x 0,25 7,6 14,4 75,0 16

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

309
Single Conductors

HELUFLON-FEP-6Y fluorinated polymeric materials, single core, 600 V

Technical data Cable structure Properties


Fluorinated polymeric insulation FEP Stranded copper wire, bare, tinned, silver Higher insulation resistance
(Fluorethylenepropylene) Make-up fine wire stranded to Low dielectric loss
Temperature range DIN VDE 0295 cl.5, BS 6360 cl.5 and Not flammable
-100C to +205C IEC 60228 cl.5 Min. 20 kV dielectric strength
(up to +230C for short time) Core insulation FEP-HELUFLON Resistant to micro-cultures
Nominal voltage 600 V Do not permit any fungus-formation
Test voltage 2500 V Absolute ozone resistant
Insulation resistance Absolute weather resistant
min. 2 GOhm x km Water absorption <0,01%
Minimum bending radius Minimal water vapour permeability
flexing 10x core (approx. 0,18 mgr/cm in 24 hours)
fixed installation 4x core The materials used in manufacture are
Radiation resistance cadmium-free and contain no silicone
up to 1x106 cJ/kg (up to 1 Mrad) and free from substances harmful to
Conductor temperature range the wetting properties of lacquers
bare copper +130C Tests
tinned copper +180C self-extinguishing and flame retardant
silver pl. copper +260C acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)

Note
Please complete the above part-no. for the
colour required using the following table:
1 = black, 2 = red, 3 = blue,
4 = brown, 5 = white, 6 = transparent,
7 = 2-colour, 8 = other colours
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
HELUFLON single cores are predominantly used for installing in control cabinets subjected to high thermal effects as well as in brickworks, heaters,
kitchen fitments and measuring appliances as well as in the chemical industry. These single cores are non-flammable and resistant to acids, alkalis,
solvents, oil and petrol.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Copper wire, tinned Copper wire, bare
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
2551x 1 x 0,14 1,0 1,4 2,6 26 2496x 1 x 2,5 2,6 24,0 26,4 14
2552x 1 x 0,25 1,1 2,4 4,1 24 2497x 1x4 3,2 38,0 43,1 12
2553x 1 x 0,5 1,4 4,8 8,0 20 2498x 1x6 3,9 58,0 65,9 10
2554x 1 x 0,75 1,5 7,2 9,7 18 2499x 1 x 10 5,1 96,0 115,0 8
2555x 1x1 1,8 9,6 12,7 17 2037x 1 x 16 6,7 154,0 175,0 6
2556x 1 x 1,5 2,2 14,4 17,9 16
2557x 1 x 2,5 2,6 24,0 26,4 14 copper wires, silvered
2558x 1x4 3,2 38,0 43,1 12 Part no. No.cores x Outer Cop. AG Weight AWG-No.
2559x 1x6 3,9 58,0 65,9 10 cross-sec. approx. mm weight weight approx.
2560x 1 x 10 5,1 96,0 115,0 8 mm kg / km kg / km kg / km
2561x 1 x 16 6,7 154,0 175,0 6 2026x 1 x 0,14 1,0 1,35 0,09 2,6 26
2027x 1 x 0,25 1,1 2,4 0,13 4,1 24
Copper wire, bare 2028x 1 x 0,5 1,4 4,8 0,17 8,0 20
Part no. No.cores x Outer Cop. Weight AWG-No. 2029x 1 x 0,75 1,5 7,2 0,20 9,7 18
cross-sec. approx. mm weight approx. 2030x 1x1 1,8 9,6 0,26 12,7 17
mm kg / km kg / km 2031x 1 x 1,5 2,2 14,4 0,35 17,9 16
2490x 1 x 0,14 1,0 1,35 2,6 26 2032x 1 x 2,5 2,6 24,0 0,70 26,4 14
2491x 1 x 0,25 1,1 2,4 4,1 24 2033x 1x4 3,2 38,0 1,20 43,1 12
2492x 1 x 0,5 1,4 4,8 8,0 20 2034x 1x6 3,9 58,0 1,70 65,9 10
2493x 1 x 0,75 1,5 7,2 9,7 18 2035x 1 x 10 5,1 96,0 2,80 115,0 8
2494x 1x1 1,8 9,6 12,7 17 2036x 1 x 16 6,7 154,0 4,80 175,0 6
2495x 1 x 1,5 2,2 14,4 17,9 16

Dimensions and specifications may be changed without prior notice. (RK01)

310
Single Conductors

HELUFLON-PTFE-5Y fluorinated polymeric materials, single core,


600 V or 1000 V

Technical data Cable structure Properties


Fluorinated polymeric insulation PTFE Stranded copper wire, silver Higher insulation resistance
(Polytetrafluorethylene) Core insulation PTFE-HELUFLON to Low dielectric loss
Design to DIN VDE 0881 an IEC 60673 DIN VDE 207 part 6 Not flammable
Temperature range PTFE as per MIL-W 16878 Resistant to micro-cultures
-190C to +260C Do not permit any fungus-formation
(up to +300C for short time) Absolute ozone resistant
Nominal voltage Absolute weather resistant
type E = 600 V Water absorption <0,01%
type EE = 1000 V Minimal water vapour permeability
Test voltage (approx. 0,18 mgr/cm in 24 hours)
type E = 3,4 kV The materials used in manufacture are
type EE = 5 kV cadmium-free and contain no silicone
Insulation resistance and free from substances harmful to
min. 1 GOhm x km the wetting properties of lacquers
Minimum bending radius Tests
10x core self-extinguishing and flame retardant
Radiation resistance acc. to DIN VDE 0482-332-1-2,
up to 1x105 cJ/kg (up to 0,1 Mrad) DIN EN 60332-1-2, IEC 60332-1 (equivalent

K
Conductor temperature range DIN VDE 0472 part 804 test method B)
bare copper +130C
tinned copper +180C Note
silver pl. copper +200C Please complete the above part-no. for the
nickel pl. copper +260C colour required using the following table:
1 = black, 2 = red, 3 = blue,
4 = brown, 5 = white, 6 = transparent,
7 = 2-colour, 8 = other colour
Conductor bare, tinned or nickel plated on
request

Application
HELUFLON single cores are predominantly used for installing in control cabinets subjected to high thermal effects as well as in brickworks, heaters,
kitchen fitments and measuring appliances as well as in the chemical industry. These single cores are non-flammable and resistant to acids, alkalis,
solvents, oil and petrol.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
600 V 1000 V
Part no. AWG-No. No. Cross- Outer Cop. AG Weight Part no. AWG-No. No. Cross- Outer Cop. AG Weight
cond. section approx. weight weight approx. cond. section approx. weight weight approx.
mm mm kg / km kg / km kg / km mm mm kg / km kg / km kg / km
2511x 32 7 0,03 0,70 0,4 0,03 0,4 2531x 32 7 0,03 1,00 0,4 0,03 0,42
2512x 30 7 0,06 0,81 0,6 0,04 0,59 2532x 30 7 0,06 1,07 0,6 0,04 0,65
2513x 28 7 0,09 0,89 0,9 0,06 0,93 2533x 28 7 0,09 1,14 0,9 0,06 1,0
2514x 26 7 0,14 0,99 1,4 0,07 1,47 2534x 26 7 0,14 1,24 1,4 0,07 1,56
2515x 26 19 0,14 0,99 1,4 0,09 1,58 2535x 26 19 0,14 1,24 1,4 0,09 1,68
2516x 24 7 0,21 1,12 2,3 0,07 2,31 2536x 24 7 0,21 1,37 2,3 0,07 2,4
2517x 24 19 0,24 1,12 2,3 0,13 2,52 2537x 24 19 0,24 1,37 2,3 0,13 2,65
2518x 22 7 0,35 1,27 3,5 0,10 3,68 2538x 22 7 0,35 1,52 3,5 0,10 3,85
2519x 22 19 0,38 1,27 3,5 0,17 3,99 2539x 22 19 0,38 1,50 3,5 0,17 4,2
2520x 20 7 0,57 1,47 5,6 0,12 6,0 2540x 20 7 0,57 1,72 5,6 0,12 6,3
2521x 20 19 0,57 1,47 6,1 0,18 6,4 2541x 20 19 0,57 1,72 6,1 0,18 6,9
2522x 18 7 0,90 1,74 9,6 0,22 9,45 2542x 18 7 0,90 2,00 9,6 0,22 10,65
2523x 18 19 0,95 1,74 9,6 0,27 10,2 2543x 18 19 0,95 2,00 9,6 0,27 13,65
2524x 16 19 1,23 2,04 13,5 0,29 12,9 2544x 16 19 1,23 2,26 13,5 0,29 21,38
2525x 14 19 1,94 2,40 18,0 0,38 20,3 2545x 14 19 1,94 2,76 18,0 0,38 33,95

Dimensions and specifications may be changed without prior notice. (RK01)

311
Single Conductors

HELUTHERM 400 Insulation class C, halogen-free

Technical data Cable structure Properties


Special core insulation mono or multi Stranded nickel conductor These cables have very good electronic,
coloured Overlapping with special heat-resistant chemical and radiation resistant properties
Temperature range impregnation
-60C to +400C Colour identification through helix Note
operating temperature (colour see table) Also available with additional Kapton film
(up to +450C for short time) at extra cost.
Nominal voltage 500 V
Test voltage 2000 V
Minimum bending radius
15x outer
Radiation resistance
up to 1x1010 cJ/kg (up to 1x104 Mrad)

Application
The wide temperature range offered by this cable type makes it especially suited for use in the aviation and aerospace industries, for atomic power
stations and in the steel making and chemical industries. For the critical applications, for example mechanical stress, we advise for consultation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Cross- Conductor Outer Nickel BK GN-YE BU BN RD WH GY VT YE PK OG BEIGE TRANS 2-col.


sec. construction approx. weight
mm mm kg / km
Part no. 50901 50900 50902 50903 50904 50905 50906 50907 50908 50911 50909 50912 50910 50913
0,5 16 x 0,2 2,2 4,8 - - - - - - - - - - - - - -
Part no. 50915 50914 50916 50917 50918 50919 50920 50921 50922 50925 50923 50926 50924 50927
0,75 24 x 0,2 2,4 7,2 - - - - - - - - - - - - - -
Part no. 50929 50928 50930 50931 50932 50933 50934 50935 50936 50939 50937 50940 50938 50941
1 32 x 0,2 2,7 9,6 - - - - - - - - - - - - - -
Part no. 50943 50942 50944 50945 50946 50947 50948 50949 50950 50953 50951 50954 50952 50955
1,5 30 x 0,25 2,8 14,4 - - - - - - - - - - - - - -
Part no. 50957 50956 50958 50959 50960 50961 50962 50963 50964 50967 50965 50968 50966 50969
2,5 50 x 0,25 3,4 24,0 - - - - - - - - - - - - - -
Part no. 50971 50970 50972 50973 50974 50975 50976 50977 50978 50981 50979 50982 50980 50983
4 56 x 0,3 4,5 38,0 - - - - - - - - - - - - - -
Part no. 50985 50984 50986 50987 50988 50989 50990 50991 50992 50995 50993 50996 50994 50997
6 84 x 0,3 4,9 58,0 - - - - - - - - - - - - - -
Part no. 50890 50209 50891 50892 50893 50894 50895 50896 50897 51560 50898 51561 51559 51562
10 141 x 0,3 5,8 96,0 - - - - - - - - - - - - - -
Part no. 51564 51563 51565 51566 51567 51568 51569 51570 51571 51574 51572 51575 51573 51576
16 226 x 0,3 7,4 154,0 - - - - - - - - - - - - - -
Part no. 51578 51577 51579 51580 51581 51582 51583 51584 51585 51588 51586 51589 51587 51590
25 196 x 0,4 9,6 240,0 - - - - - - - - - - - - - -
Part no. 51592 51591 51593 51594 51595 51596 51597 51598 51599 51602 51600 51603 51601 51604
35 276 x 0,4 11,5 336,0 - - - - - - - - - - - - - -
Part no. 51606 51605 51607 51608 51609 51610 51611 51612 51613 51616 51614 51617 51615 51618
50 396 x 0,4 12,7 480,0 - - - - - - - - - - - - - -
Part no. 51620 51619 51621 51622 51623 51624 51625 51626 51627 51630 51628 51631 51629 51632
70 360 x 0,5 16,0 672,0 - - - - - - - - - - - - - -
Part no. 51634 51633 51635 51636 51637 51638 51639 51640 51641 51644 51642 51645 51643 51646
95 485 x 0,5 18,0 912,0 - - - - - - - - - - - - - -
Part no. 51648 51647 51649 51650 51651 51652 51653 51654 51655 51658 51656 51659 51657 51660
120 608 x 0,5 19,0 1152,0 - - - - - - - - - - - - - -
Part no. 51662 51661 51663 51664 51665 51666 51667 51668 51669 51672 51670 51673 51671 51674
150 756 x 0,5 22,0 1440,0 - - - - - - - - - - - - - -
Part no. 51676 51675 51677 51678 51679 51680 51681 51682 51683 51686 51684 51687 51685 51688
185 944 x 0,5 24,0 1776,0 - - - - - - - - - - - - - -
Part no. 51690 51689 51691 51692 51693 51694 51695 51696 51697 51700 51698 51701 51699 51702
240 1222 x 0,5 27,0 2304,0 - - - - - - - - - - - - - -

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

312
Single Conductors

HELUTHERM 600 / 600-ES halogen-free / high-grade steel braiding

Technical data Cable structure Properties


Special core insulation for high HELUTHERM 600 Asbestos and cadmium-free
temperatures Stranded nickel conductor
Temperature range Double-insulated glass-fibre braiding, Note
-60C to +600C impregnated with silicone AWG sizes are approximate equivalent
Permissible temperature Braiding of special mineral fibres and values. The actual cross-section is in mm.
+400C to +600C additional impregnation with silicone
(up to +700C for short time) HELUTHERM 600-ES
Nominal voltage 500 V As per above
Test voltage 2500 V Additional braided high-grade steel,
Minimum bending radius coverage approx. 80%
15x outer

Application
HELUTHERM 600
Cables are used in applications where extremely high connecting and ambient temperatures occur, e. g. in iron and steel works, rolling mills, foundries,
glass and ceramic plants, in power construction as well as for wiring resistances in electrical heating equipment, furnaces and in thermoplastic forming.
Good characteristics in the presence of moisture and chemical effects.
HELUTHERM 600-ES
The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The high-grade braiding also gives
this cable an attractive appearance. The braided screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC. K
HELUTHERM 600

Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +400C (A)
51703 1 x 0,25 4 x 0,3 2,0 346 1,5 2,4 9,5 24
51704 1 x 0,5 7 x 0,3 2,3 175 2,5 4,8 11,5 20
51705 1 x 0,75 11 x 0,3 2,6 115 4,5 7,2 15,0 18
51706 1x1 14 x 0,3 2,8 88 5,5 9,6 17,8 17
51707 1 x 1,5 21 x 0,3 3,2 59 7 14,4 24,0 16
51708 1 x 2,5 35 x 0,3 3,7 35 10 24,0 36,0 14
51709 1x4 56 x 0,3 4,5 22 13,5 38,0 54,5 12
51710 1x6 84 x 0,3 6,0 14,6 16 58,0 77,0 10
51711 1 x 10 140 x 0,3 8,0 8,8 21 96,0 150,0 8
51712 1 x 16 228 x 0,3 9,1 5,5 28 154,0 225,0 6
51713 1 x 25 354 x 0,3 10,8 3,5 36 240,0 340,0 4
51714 1 x 35 495 x 0,3 13,0 2,5 58 336,0 440,0 2
51715 1 x 50 707 x 0,3 13,5 1,5 70 480,0 600,0 1

HELUTHERM 600-ES
Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +400C (A)
50475 1 x 0,5 7 x 0,3 3,2 175 2,5 4,8 21,0 20
50476 1 x 0,75 11 x 0,3 3,5 115 4,5 7,2 29,0 18
50477 1x1 14 x 0,3 3,7 88 5,5 9,6 38,0 17
50478 1 x 1,5 21 x 0,3 4,1 59 7 14,4 44,0 16
50479 1 x 2,5 35 x 0,3 4,6 35 10 24,0 56,0 14
50480 1x4 56 x 0,3 5,4 22 13,5 38,0 78,0 12
50481 1x6 84 x 0,3 6,9 14,6 16 58,0 112,0 10
50482 1 x 10 140 x 0,3 8,9 8,8 21 96,0 198,0 8
50483 1 x 16 228 x 0,3 10,0 5,5 28 154,0 281,0 6
50484 1 x 25 354 x 0,3 11,7 3,5 36 240,0 410,0 4
50485 1 x 35 495 x 0,3 15,1 2,5 58 336,0 536,0 2
50486 1 x 50 707 x 0,3 15,6 1,5 70 480,0 697,0 1

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

313
Single Conductors

HELUTHERM 800 / 800-ES halogen-free / high-grade steel braiding

Technical data Cable structure Properties


Special core insulation for high HELUTHERM 800 Asbestos and cadmium-free
temperatures Stranded nickel conductor
Temperature range Double-insulated glass-fibre braiding, Note
-120C to +750C impregnated with silicone AWG sizes are approximate equivalent
Permissible temperature Braiding of special mineral fibres and values. The actual cross-section is in mm.
+600C to +800C additional impregnation with silicone
(up to +1200C for short time) HELUTHERM 800-ES
Nominal voltage 500 V As per above
Test voltage 2000 V Additional braided high-grade steel,
Minimum bending radius coverage approx. 80%
15x outer

Application
HELUTHERM 800
Cables are used in applications where extremely high connecting and ambient temperatures occur, e. g. in iron and steel works, rolling mills, foundries,
glass and ceramic plants, in power construction as well as for wiring resistances in electrical heating equipment, furnaces and in thermoplastic forming.
Good characteristics in the presence of moisture and chemical effects.
HELUTHERM 800-ES
The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The high-grade braiding also gives
this cable an attractive appearance. The braided screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
HELUTHERM 800
Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +700C (A)
51716 1 x 0,25 4 x 0,3 2,2 346 1 2,4 10,2 24
51717 1 x 0,5 7 x 0,3 2,3 175 2 4,8 12,0 20
51718 1 x 0,75 11 x 0,3 2,9 115 3 7,2 16,0 18
51719 1x1 14 x 0,3 3,2 88 4 9,6 19,0 17
51720 1 x 1,5 21 x 0,3 3,2 59 5 14,4 26,5 16
51721 1 x 2,5 35 x 0,3 3,7 35 7 24,0 38,8 14
51722 1x4 56 x 0,3 4,5 22 9 38,0 57,0 12
51723 1x6 84 x 0,3 5,9 14,6 12 58,0 81,0 10
51724 1 x 10 140 x 0,3 8,0 8,8 14 96,0 156,0 8
51725 1 x 16 228 x 0,3 9,0 5,5 20 154,0 240,0 6
51726 1 x 25 354 x 0,3 10,6 3,5 24 240,0 370,0 4
51727 1 x 35 495 x 0,3 13,4 2,5 40 336,0 490,0 2
51728 1 x 50 707 x 0,3 14,0 1,5 48 480,0 645,0 1

HELUTHERM 800-ES
Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +700C (A)
50488 1 x 0,5 7 x 0,3 3,5 175 2 4,8 23,0 20
50489 1 x 0,75 11 x 0,3 3,8 115 3 7,2 31,0 18
50490 1x1 14 x 0,3 4,1 88 4 9,6 40,0 17
50491 1 x 1,5 21 x 0,3 4,5 59 5 14,4 47,0 16
50492 1 x 2,5 35 x 0,3 4,9 35 7 24,0 59,0 14
50493 1x4 56 x 0,3 5,8 22 9 38,0 82,0 12
50494 1x6 84 x 0,3 7,3 14,6 12 58,0 118,0 10
50495 1 x 10 140 x 0,3 9,4 8,8 14 96,0 209,0 8
50496 1 x 16 228 x 0,3 10,5 5,5 20 154,0 298,0 6
50497 1 x 25 354 x 0,3 12,2 3,5 24 240,0 452,0 4
50498 1 x 35 495 x 0,3 15,5 2,5 40 336,0 592,0 2
50499 1 x 50 707 x 0,3 16,1 1,5 48 480,0 650,0 1

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

314
Single Conductors

HELUTHERM 1200 / 1200-ES halogen-free / high-grade steel braiding

Technical data Cable structure Properties


Special core insulation for high HELUTHERM 1200 Asbestos and cadmium-free
temperatures Stranded nickel conductor
Temperature range Double-insulated glass-fibre braiding, Note
-170C to +1000C impregnated with silicone AWG sizes are approximate equivalent
Permissible temperature Braiding of special mineral fibres and values. The actual cross-section is in mm.
+800C to +1100C additional impregnation with silicone
(up to +1400C for short time) HELUTHERM 1200-ES
Nominal voltage 500 V As per above
Test voltage 2000 V Additional braided high-grade steel,
Minimum bending radius coverage approx. 80%
15x outer

Application
HELUTHERM 1200
Cables are used in applications, where extremely high connecting and ambient temperatures occur, e. g. in iron and steel works, rolling mills, foundries,
glass and ceramic plants, in furnace and power plant construction as well for wiring resistances in electrical heating equipment, furnaces and in
thermoplastic forming. Good characteristics in the presence of moisture and chemical effects.
HELUTHERM 1200-ES
The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The high-grade braiding also gives
this cable an attractive appearance. The braided screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC. K
HELUTHERM 1200

Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +700C (A)
51729 1 x 0,5 7 x 0,3 2,3 175 2 4,8 12,3 20
51730 1 x 0,75 11 x 0,3 2,6 115 3 7,2 16,1 18
51731 1x1 14 x 0,3 2,8 88 4 9,6 19,8 17
51732 1 x 1,5 21 x 0,3 3,2 59 5 14,4 27,5 16
51733 1 x 2,5 35 x 0,3 3,7 35 7 24,0 39,8 14
51734 1x4 56 x 0,3 4,5 22 9 38,0 58,0 12
51735 1x6 84 x 0,3 5,9 14,6 12 58,0 83,0 10
51736 1 x 10 140 x 0,3 8,0 8,8 14 96,0 160,0 8
51737 1 x 16 228 x 0,3 9,0 5,5 20 154,0 244,0 6
51738 1 x 25 354 x 0,3 10,6 3,5 24 240,0 376,0 4
51739 1 x 35 495 x 0,3 13,6 2,5 40 336,0 495,0 2
51740 1 x 50 707 x 0,3 14,5 1,5 48 480,0 654,0 1

HELUTHERM 1200-ES
Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +700C (A)
50635 1 x 0,5 7 x 0,3 3,6 175 2 4,8 26,0 20
50636 1 x 0,75 11 x 0,3 3,8 115 3 7,2 34,0 18
50637 1x1 14 x 0,3 4,2 88 4 9,6 42,0 17
50638 1 x 1,5 21 x 0,3 4,7 59 5 14,4 53,0 16
50639 1 x 2,5 35 x 0,3 5,0 35 7 24,0 64,0 14
50640 1x4 56 x 0,3 6,0 22 9 38,0 87,0 12
50641 1x6 84 x 0,3 7,5 14,6 12 58,0 120,0 10
50642 1 x 10 140 x 0,3 9,7 8,8 14 96,0 218,0 8
50643 1 x 16 228 x 0,3 10,9 5,5 20 154,0 314,0 6
50644 1 x 25 354 x 0,3 12,9 3,5 24 240,0 453,0 4
50645 1 x 35 495 x 0,3 15,7 2,5 40 336,0 593,0 2
50646 1 x 50 707 x 0,3 16,7 1,5 48 480,0 760,0 1

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

315
Single Conductors

Earth Conductors ESUY and ESY

Technical data Cable structure Properties


ESUY (H00 V-D) ESUY (H00V-D) For these cable types no nominal voltages
Earthing cable of braid wires over Bare copper-conductor, extra fine-wire, are mentioned, as these are: only used for
core strands in adapted to high flexible earthing performances
DIN VDE 0283 part 3 and EN 61138 Braiding of bare copper wires over the For further requirements see European
ESY stranded copper conductor Norm EN 61230 and DIN VDE 0683 part 100:
Earthing cable in adapted to Outer sheath of PVC "Live working - Portable equipment for
DIN VDE 0283 part 3 and EN 61138 compound type TM2 according earthing and earthing"
ESUY (H00 V-D) and ESY DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Conductor resistance at 20C Sheath colour transparent (glass clear) Note
according DIN VDE 0283 part 3 ESY AWG sizes are approximate equivalent
Temperature range Bare Cu-conductor, fine-wire values. The actual cross-section is in mm.
-5C to +70C Copper conductors of stranded wires
Test voltage 2000 V Outer sheath of PVC
Spark test (during winding) compound type TM2 according
16 mm to 35 mm = 5000 V DIN VDE 0207-363-4-1/DIN EN 50363-4-1
50 mm to 70 mm = 6000 V Sheath colour transparent (glass clear)
95 mm to 240 mm = 8000 V
Insulation resistance
min. 20 MOhm x km
Minimal bending radius
12x outer

Application
ESUY (H00V-D)
These high flexible earth conductors are used for earthing of portable equipment and short-circuiting. These cables specially perform a protective
function in repair live working of high voltage power supply company as EVU, in railway systems, failing current equipment, alternating current systems
and in networks of transmission and distribution. Because of that these are designated as safety cables.
ESY
These earthing cables offer special characteristics with low weights, high flexibility to a wide temperature range and the behavior in high temperature.
The protective sheath over conductor assures the essential function for protection against the mechanical and chemical stresses.
ESUY (H00V-D), high flexible
Part no. Cross- Cond. make-up Outer Cop. Weight AWG-No.
section n x wire approx. mm weight approx. kg / km
mm kg / km
28930 16 4200 x 0,07 8,3 194,0 230,0 6
28931 25 3192 x 0,1 9,5 280,0 335,0 4
28932 35 4480 x 0,1 11,2 415,0 475,0 2
28933 50 6383 x 0,1 13,2 585,0 670,0 1
28934 70 8918 x 0,1 15,6 820,0 905,0 2/0
28935 95 12100 x 0,1 17,4 1090,0 1220,0 3/0
28936 120 15300 x 0,1 19,8 1360,0 1505,0 4/0
28937 150 19152 x 0,1 23,4 1650,0 1940,0 300 kcmil
28938 185 23580 x 0,1 26,6 2150,0 2390,0 350 kcmil
28939 240 30600 x 0,1 30,2 2750,0 3090,0 500 kcmil

ESY, flexible
Part no. Cross- Cond. make-up Outer Cop. Weight AWG-No.
section n x wire approx. mm weight approx. kg / km
mm kg / km
28940 16 525 x 0,2 8,4 155,0 185,0 6
28941 25 798 x 0,2 9,8 240,0 270,0 4
28942 35 1120 x 0,2 11,4 336,0 390,0 2
28943 50 1617 x 0,2 13,8 480,0 575,0 1
28944 70 2254 x 0,2 16,4 672,0 810,0 2/0
28945 95 3087 x 0,2 18,2 912,0 1080,0 3/0
28946 120 3822 x 0,2 20,1 1152,0 1320,0 4/0
28947 150 4802 x 0,2 23,0 1440,0 1680,0 300 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

316
Single Conductors

GALVANICABLE high-current cable, high flexible and halogen-free

Technical data Cable structure Properties


Temperature range Bare copper, ultra-fine wire conductors PUR wearing sheath: extremely abrasion
flexing -40C to +80C acc. to DIN VDE 0295 cl.6 and IEC 60228 resistant, halogen-free, resistant to UV, oil,
fixed installation -50C to +80C cl.6 hydrolysis and microbial attack
Nominal voltage Extremely thick PUR wearing sheath Chemical resistance:
U0/U 0,6/1 kV Natural colour, smooth, glossy PUR demonstrates significantly better
Test voltage chemical resistance when compared with
3500 V other materials, e.g. rubber or PVC
Insulation resistance The extremely thick polyurethane sheath
min. 20 MOhm/km stands for a longer life
Minimum bending radius
15x cable

Application
This cable is employed as a highly-flexible high-current cathode cable for electroplating drum systems and as a wearing cable in the chemical industry.
Special feature: Despite the extremely thick wearing sheath, the highly flexible conductor enables good contact when installing the pear push. Good
flexibility is likewise ensured when the pear push comes into contact with the parts to be electroplated.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.

K
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
700768 1 x 35 17,2 336,0 548,0 2 74749 1 x 120 27,0 1152,0 1520,0 4/0
75497 1 x 50 19,0 480,0 686,0 1 700769 1 x 150 28,0 1440,0 2002,0 300 kcmil
75498 1 x 70 21,5 672,0 950,0 2/0 700770 1 x 185 30,5 1776,0 2610,0 350 kcmil
75499 1 x 95 24,0 912,0 1386,0 3/0 700771 1 x 240 36,0 2304,0 3820,0 500 kcmil

Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

317
Single Conductors

H01N2-D / H01N2-E 100 V, VDE approved, welding cable

Technical data Cable structure Properties


Harmonized welding cable with Bare Cu- conductor, extra fine-wire Test according to DIN VDE 0482-332-1-2,
rubber sheath, according to to DIN VDE 0295, BS 6360, IEC 60228 DIN EN 60332-1-2/ IEC 60332-1 (equivalent
DIN VDE 0285-525-2-81 / Separator over conductor DIN VDE 0472 part 804 test method B)
DIN EN 50525-2-81 Neoprene outer sheath, chlorinated Oil resistant to
Temperature range rubber compound EM5 DIN VDE 0473-811-404/ DIN EN
flexing -25C to +80C Sheath colour black 60811-404
fixed installation -40C to +80C Without green-yellow marking The cable also maintains its high flexibilty
Admissible working temperature under the effect of ozone, light, oxygen,
at conductor +85C inert gas, oil or petrol
Nominal voltage U0/U 100/100 V
Test voltage 1000 V Note
Minimum bending radius No. wires = Gauiding value;
H01N2-D 12x outer the number of individual wires
H01N2-E 10x outer are without obligation.
Tinned conductor on request
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
For use between the welding generator and the hand-electrode and the workpiece. For use in the automobile industry, in shipbuilding, in transport
and conveyor systems, tool making machinery, welding robots etc. These cables retain their high flexibility even under influence of ozone, light,
oxygen, protective gases, oil and petrol. The robust construction makes these cables resistant to both to cold and the heat as well as to flames. They
are suitable for use in open spaces and in dry and damp conditions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H01N2-D: Cables with standard flexibility
Part no. No.cores x No.wires x Sheat Outer Cop. Weight AWG-No.
cross-sec. single wire Nominal value min. - max. weight approx. kg / km
mm mm mm mm kg / km
31001 1 x 10 320 x 0,2 2,0 7,7 - 9,7 96,0 135,0 8
31002 1 x 16 512 x 0,2 2,0 8,8 - 11,0 154,0 205,0 6
31003 1 x 25 800 x 0,2 2,0 10,1 - 12,7 240,0 302,0 4
31004 1 x 35 1120 x 0,2 2,0 11,4 - 14,2 336,0 420,0 2
31005 1 x 50 1600 x 0,2 2,2 13,2 - 16,5 480,0 586,0 1
31006 1 x 70 2240 x 0,2 2,4 15,3 - 19,2 672,0 798,0 2/0
31007 1 x 95 3024 x 0,2 2,6 17,1 - 21,4 912,0 1015,0 3/0
31008 1 x 120 614 x 0,5 2,8 19,2 - 24,0 1152,0 1310,0 4/0
31030 1 x 150 765 x 0,5 3,0 21,2 - 26,4 1440,0 1620,0 300 kcmil
31031 1 x 185 944 x 0,5 3,2 23,1 - 28,9 1776,0 1916,0 350 kcmil
31009 1 x 240 1225 x 0,5 3,4 25,0 - 29,5 2304,0 2540,0 500 kcmil

H01N2-E: Cables with extreme high flexibility


Part no. No.cores x No.wires x Sheat Outer Cop. Weight AWG-No.
cross-sec. single wire Nominal value min. - max. weight approx. kg / km
mm mm mm mm kg / km
31032 1 x 10 566 x 0,15 1,2 6,2 - 7,8 96,0 119,0 8
31033 1 x 16 903 x 0,15 1,2 7,3 - 9,1 154,0 181,0 6
31034 1 x 25 1407 x 0,15 1,2 8,6 - 10,8 240,0 270,0 4
31035 1 x 35 1974 x 0,15 1,2 9,8 - 12,3 336,0 363,0 2
31036 1 x 50 2830 x 0,15 1,5 11,9 - 14,8 480,0 528,0 1
31037 1 x 70 3952 x 0,15 1,5 13,6 - 17,0 672,0 716,0 2/0
31038 1 x 95 5370 x 0,15 1,8 15,6 - 19,5 912,0 1012,0 3/0
31039 1 x 120 3819 x 0,2 1,8 17,2 - 21,6 1152,0 1190,0 4/0
31019 1 x 150 4788 x 0,2 1,8 18,8 - 23,5 1440,0 1305,0 300 kcmil
31020 1 x 185 5852 x 0,2 1,8 20,4 - 25,5 1776,0 1511,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

318
Single Conductors

NSGAFU 3kV Special Rubber-Insulated Cable, VDE approved, short-circuit


up to 1000 V

Technical data Cable structure Properties


Special rubber-insulated single core cables Tinned copper, fine wire conductors, bunch Oil resistant
to DIN VDE 0250 part 602 stranded to DIN VDE 0295 cl.5 and Test to DIN VDE 0473-811-404/
Temperature range IEC 60228 cl.5 DIN EN 60811-404
flexing -25C to +80C EPR-insulation, compound type 3GI3 to Behaviour in fire
fixed installation -40C to +80C DIN VDE 0207 part 20 to DIN VDE 0482-332-1-2
Permissible operating temperature Outer casing: Polychloroprene 5GM3 DIN EN 60332-2-1, IEC 60332-1 (equivalent
at conductor +90C acc. to DIN VDE 0207 part 21 DIN VDE 0472 part 804 test method B)
Nominal voltage U0/U 1,8/3 kV Colour black Considered as being short-circuit safe and
Max. permissible operating voltage inherently earth-fault-proof are those
in three and one-phase alternating operating materials and conducting
current operation U0/U 2,1/3,6 kV, for assemblies where because of suitable
direct current operation U0/U 2,7/5,4 kV measures and/or means applied, neither a
Test voltage 6 kV short circuit nor a short to ground is to be
Minimum bending radius expected under operating conditions which
flexing 10x outer are in accordance with those specified for
fixed installation 6x outer the intended application.

Note
Version in 6 kV available on request.
AWG sizes are approximate equivalent K
values. The actual cross-section is in mm.

Application
Particularly suitable for protection against short circuits in laying and for inherently earth-fault-proof routing in rail vehicles and omnibuses. Also
suitable for laying in dry environments.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
38501 1 x 1,5 7,0 14,4 62,0 16 38509 1 x 50 18,0 480,0 650,0 1
38502 1 x 2,5 7,5 24,0 76,0 14 38510 1 x 70 20,5 672,0 900,0 2/0
38503 1x4 9,0 38,0 95,0 12 38511 1 x 95 24,0 912,0 1200,0 3/0
38504 1x6 9,5 58,0 140,0 10 38513 1 x 120 26,0 1152,0 1450,0 4/0
38505 1 x 10 11,0 96,0 190,0 8 38514 1 x 150 28,0 1440,0 1800,0 300 kcmil
38506 1 x 16 13,0 154,0 270,0 6 38512 1 x 185 31,0 1776,0 2200,0 350 kcmil
38507 1 x 25 15,0 240,0 410,0 4 38515 1 x 240 34,5 2304,0 2650,0 500 kcmil
38508 1 x 35 16,5 336,0 490,0 2 38516 1 x 300 38,0 2880,0 3250,0 600 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

319
Single Conductors

NSHXAF 3kV halogen-free Special Rubber-Insulated Cable, VDE approved,


short-circuit up to 1000 V

Technical data Cable structure Properties


Special rubber core cable acc. to Tinned copper conductor, fine wire Tests
E DIN VDE 0250 part 606 to DIN VDE 0295 cl.5, BS 6360 cl.5 Corrosiveness of corrosive gases
Temperature range and/or IEC 60228 cl.5 acc. to DIN VDE 0482 part 267,
flexing -25C to +70C EPR-insulation, 3GI3 acc. to DIN VDE 0207 DIN EN 50267-2-2, IEC 607542
fixed installation -40C to +90C part 20 (equivalent DIN VDE 0472 part 813)
Permissible operating temperature Outer casing: halogen-free polymer Smoke density
at conductor +90C compound HM3 acc. to acc. to DIN VDE 0482
Nominal voltage U0/U 1,8/3 kV DIN VDE 0207 part 24 part 1034-1+2, DIN EN 61034-1+2,
Highest permissible operating voltage Colour black IEC 61034-1+2, BS 7622 part 1+2
in three-phase and one-phase (equivalent DIN VDE 0472 part 816)
a.c. systems U0/U 2,1/3,6 kV Oil resistant
in d.c. systems U0/U 2,7/5,4 kV acc. to DIN VDE 0473-811-404,
Test voltage 6 kV DIN EN 60811-404
Minimum bending radius Behaviour in fire
flexing 10x outer to DIN VDE 0482-332-1-2
fixed 6x outer DIN EN 60332-2-1, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Particularly suitable for protection against short circuits in laying and for inherently earth-fault-proof routing in rail vehicles and omnibuses. Also
suitable for laying in dry environments. In switching units and distributors, they are considered to be short circuit and inherently earth proof to
1000 V. Note: Considered as being short-circuit safe and inherently earth-fault-proof are those operating materials and conducting assemblies where
because of suitable measures and/or means applied, neither a short circuit nor a short to ground is to be expected under operating conditions which
are in accordance with those specified for the intended application.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
38517 1 x 1,5 5,9 14,4 62,0 16 38525 1 x 50 14,5 480,0 650,0 1
38518 1 x 2,5 6,2 24,0 76,0 14 38526 1 x 70 16,3 672,0 900,0 4
38519 1x4 6,8 38,0 95,0 12 38527 1 x 95 19,2 912,0 1200,0 3/0
38520 1x6 7,4 58,0 140,0 10 38528 1 x 120 21,0 1152,0 1450,0 4/0
38521 1 x 10 8,7 96,0 190,0 8 38529 1 x 150 22,8 1440,0 1800,0 300 kcmil
38522 1 x 16 9,5 154,0 270,0 6 38530 1 x 185 24,8 1776,0 2200,0 350 kcmil
38523 1 x 25 11,9 240,0 410,0 4 38531 1 x 240 27,1 2304,0 2650,0 500 kcmil
38524 1 x 35 13,1 336,0 490,0 2 38532 1 x 300 30,3 2880,0 3250,0 600 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

Suitable accessories can be found in Chapter X.


Core end sleeve - ADI
Core end sleeve - ADU

320
Single Conductors

TOPFLEX 300 high flexible PVC single core, 0,6/1kV for drag chain and free move
application

Technical data Cable structure Properties


Special PVC single-core cable with Bare copper, extra fine wire conductor to PVC self-extinguishing and flame retardant
oil-resistant insulation based on DIN VDE 0295 cl.6 and IEC 60228 cl.6 acc. to DIN VDE 0482-332-1-2,
DIN VDE 0285-525-2-31/DIN EN Oil-resistant special PVC insulation DIN EN 60332-1-2, IEC 60332-1 (equivalent
50525-2-31 Colour see table, or as desired DIN VDE 0472 part 804 test method B)
Temperature range If this cable is to be double-insulated, then Chemical resistance see table Technical
flexing -5C to +80C its external diameter and weight must be Information
fixed installation -40C to +80C adapted.
Nominal voltage Caution with existing cables.
U0/U 600/1000 V
A.C. test voltage, 50 Hz
3000 V
Insulation resistance
min. 20 MOhm/km
Minimum bending radius
for flexible installation
7,5 cable

Application
Thanks to their outstanding alternating bending stress characteristics, these cables are ideally suited for use in drag chains, and also for use in handling
devices, robots, and nearly any area requiring flexible used and free motion. Due to its resistance to mineral oils these cables are well suited for use in K
mechanical engineering, tool making, and systems engineering, and in steel mills and rolling mills in particularly critical areas. Suitable for installation
in dry, damp and wet environments. With the black sheath, can also be used outdoors.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX 300 black TOPFLEX 300 green-yellow
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
79623 1 x 2,5 4,2 24,0 42,0 14 79627 1 G 2,5 4,2 24,0 42,0 14
79624 1x4 5,1 38,4 58,0 12 79628 1G4 5,1 38,4 58,0 12
79625 1x6 6,0 57,6 85,0 10 79629 1G6 6,0 57,6 85,0 10
79626 1 x 10 7,4 96,0 130,0 8 79630 1 G 10 7,4 96,0 130,0 8
75431 1 x 16 8,8 154,0 210,0 6 75438 1 G 16 8,8 154,0 210,0 6
75432 1 x 25 10,7 240,0 300,0 4 75439 1 G 25 10,7 240,0 300,0 4
75433 1 x 35 12,1 336,0 420,0 2 75440 1 G 35 12,1 336,0 420,0 2
70519 1 x 50 14,0 480,0 580,0 1 70536 1 G 50 14,0 480,0 580,0 1
75434 1 x 70 16,3 672,0 780,0 2/0 75441 1 G 70 16,3 672,0 780,0 2/0
73714 1 x 95 18,3 912,0 1010,0 3/0 75442 1 G 95 18,3 912,0 1010,0 3/0
75435 1 x 120 20,0 1152,0 1200,0 4/0 73885 1 G 120 20,0 1152,0 1200,0 4/0
75436 1 x 150 23,0 1440,0 1600,0 300 kcmil 75443 1 G 150 23,0 1440,0 1600,0 300 kcmil
72872 1 x 185 24,8 1776,0 2030,0 350 kcmil 75444 1 G 185 24,8 1776,0 2030,0 350 kcmil
75437 1 x 240 28,7 2304,0 2600,0 500 kcmil 75445 1 G 240 28,7 2304,0 2600,0 500 kcmil

TOPFLEX 300 red TOPFLEX 300 blue


Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
79631 1 x 2,5 4,2 24,0 42,0 14 79635 1 x 2,5 4,2 24,0 42,0 14
79632 1x4 5,1 38,4 58,0 12 79636 1x4 5,1 38,4 58,0 12
79633 1x6 6,0 57,6 85,0 10 79637 1x6 6,0 57,6 85,0 10
79634 1 x 10 7,4 96,0 130,0 8 79638 1 x 10 7,4 96,0 130,0 8
78106 1 x 16 8,8 154,0 210,0 6 78112 1 x 16 8,8 154,0 210,0 6
78107 1 x 25 10,7 240,0 300,0 4 78113 1 x 25 10,7 240,0 300,0 4
78108 1 x 35 12,1 336,0 420,0 2 78114 1 x 35 12,1 336,0 420,0 2
70518 1 x 50 14,0 480,0 580,0 1 78115 1 x 50 14,0 480,0 580,0 1
78109 1 x 70 16,3 672,0 780,0 2/0 78116 1 x 70 16,3 672,0 780,0 2/0
78110 1 x 95 18,3 912,0 1010,0 3/0 78117 1 x 95 18,3 912,0 1010,0 3/0
78111 1 x 120 20,0 1152,0 1200,0 4/0 73884 1 x 120 20,0 1152,0 1200,0 4/0

Dimensions and specifications may be changed without prior notice.

321
Single Conductors

KOMPOSPEED 600 / 600-C 0,6/1kV, halogen-free, special


single cores for drag chains, EMC-preferred type

Technical data Cable structure Properties


Special drag chain single cores for high KOMPOSPEED 600 Very good oil resistant
mechanical stress, adapted to Tinned copper, extra fine wire conductors, Halogen free
DIN VDE 0285-525-2-31/ bunch stranded to DIN VDE 0295 cl.6, Abrasion resistant
DIN EN 50525-2-31 col. 4, BS 6360 cl.6 and IEC 60228 cl.6 Resistant to
Temperature range Core insulation of special thermoplastic Coolants
flexing -30C to +90C polymer, natural coloured Microbes
fixed installation -40C to +100C Outer sheath of special polyolefin UV-radiation
Permissible operating temperature black (RAL 9005) Weather
at conductor +90C KOMPOSPEED 600-C Hydrofluoric acid
Nominal voltage U0/U 600/1000 V Structure as above up to core insulation Hydrochloric acid
Test voltage 3000 V Screen of tinned cu-braid, Diluted sulfuric acid
Insulation resistance coverage approx. 85% The materials used in manufacture are
min. 20 MOhm x km Outer sheath of special polyolefin cadmium-free and contain no silicone
Minimum bending radius black (RAL 9005) and free from substances harmful to the
KOMPOSPEED 600 wetting properties of lacquers
flexing installation 5x outer
fixed installation 3x outer Note
KOMPOSPEED 600-C AWG sizes are approximate equivalent
flexing installation 7,5x outer values. The actual cross-section is in mm.
fixed installation 4x outer

Application
The special single cores are used for permanent flexible applications in machineries, machine tools, composting appliances and sewage-treatment
plants, animal stalls and greenhouses and used for permanent flexible application for movable automated machinery parts and multi-shift operation
as well as in open air. These cables are installed for flexible use with free movements without tensile stress or forced movements and suitable for
application in drag chains. The selected tinned copper wire conductor and tinned copper wire braid permit the installation in aggressive environments
as well as hydrogen sulfide, ammonia and sulfur dioxide.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing
speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the
instructions. Further technical details see selection table for drag chain cables, see lead text.
KOMPOSPEED 600-C
These screened cables are particularly suitable for the interference-free trans mission in instrumentation and control engineering applications
(electromagnetic compatibillity).
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
KOMPOSPEED 600 KOMPOSPEED 600-C
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
60288 1x6 6,5 58,0 83,0 10 60216 1x6 7,3 71,0 101,0 10
60289 1 x 10 8,4 96,0 132,0 8 60217 1 x 10 9,1 122,0 168,0 8
60290 1 x 16 9,5 154,0 188,0 6 60218 1 x 16 10,1 180,0 217,0 6
60291 1 x 25 11,2 240,0 281,0 4 60219 1 x 25 12,2 282,0 342,0 4
60292 1 x 35 13,0 336,0 404,0 2 60220 1 x 35 14,2 386,0 468,0 2
60293 1 x 50 15,4 480,0 531,0 1 60221 1 x 50 17,0 535,0 584,0 1
60294 1 x 70 17,2 672,0 729,0 2/0 60222 1 x 70 19,2 750,0 822,0 2/0
60295 1 x 95 20,0 912,0 1049,0 3/0 60223 1 x 95 21,8 1004,0 1190,0 3/0
60296 1 x 120 21,0 1152,0 1220,0 4/0 60224 1 x 120 23,8 1260,0 1400,0 4/0
60297 1 x 150 23,8 1440,0 1510,0 300 kcmil 60225 1 x 150 26,0 1570,0 1710,0 300 kcmil
60298 1 x 185 26,2 1776,0 1932,0 350 kcmil 60226 1 x 185 28,8 1911,0 2021,0 350 kcmil
62500 1 x 240 34,0 2470,0 2850,0 500 kcmil

Dimensions and specifications may be changed without prior notice. (RK01)

322
04 | 324
COMPENSATING CABLES

Technical data Structure Use


- Special insulation of PVC, silicone, - ConFuctoTs OaFe of special OateTials )oT instTuOentation anF contTol technol-
uoTpol[OeTs, oT Ilass DeT FepenFinI - ConFuctoT t[pe )e-Cu Ni, oI[, coOpensatinI caDles also TefeTTeF
on tJe TeSuiTeOent SoNiCT-SoNi, SoPt5h-SoPt, Cu-CuNi to as coOpensation caDles aTe TeSuiTeF
- Conductor resistance in accoTFance - Insulation of PVC, silicone, foT pTecise teOpeTatuTe OeasuTeOents
with DIN 43713 uoTpol[OeTs oT Ilass-DeT The[ aTe useF as a theTOo-electTic
)e 000 ohOO - CoTe coFinI SinIle coloT see ColoT eZtension fToO the theTOocouple to the
CuNi 0327 ohOO taDle OeasuTeOent FeXice
NiCT 007 ohOO - CoFinI of the paiTs, staTtinI at 2 paiTs The coOpensatinI caDle consists of a
Ni 03 ohOO the inFiXiFual paiTs aTe OaTMeF with positiXe coTe anF a neIatiXe coTe, that
Pt5h 0023 ohOO iOpTinteF nuODeTinI IeneTate the saOe theTOo-electTic
Pt 0041 ohOO - -acMet OateTial of PVC, silicone, XoltaIe at connectoT heaF teOpeTatuTes
- Test voltages foT PVC, uoTpol[OeTs uoTpol[OeTs oT Ilass-DeT DTaiF up to 200pC, as the theTOocouple in
anF silicone-caDles - BTaiFeF scTeen of IalXani\eF steel wiTe accoTFance with DIN 43710
coTecoTe 500 V t[pe S< oT Cu-DTaiF t[pe C<
coTescTeen 500 V Materials
scTeenscTeen 500 V Measuring CoOpensatinI wiTes anF stTanFs TheTe
- Test voltage foT Ilass-DeT lines )oT teOpeTatuTe OeasuTinI, the teO- is a Fistinction Detween oTiIinal OateTi-
coTecoTe 500 V peTatuTe-FepenFent chaTacteTistics of als anF suDstitutes
- Insulation resistance OateTials aTe taMen into consiFeTation, CoOpensatinI wiTes anF stTanFs of
foT PVC, silicone anF uoTopol[OeTs foT eZaOple, the eZpansion theTOoOe- original materials aTe OaFe of the
Oin 10 MOhO Z MO
- Operating capacity
teTs oT theTOocouples, etc TeOpeTatuTe
OeasuTinI FeXices with a theTOocouple
saOe OateTial as the associateF theT-
Oocouple anF the[ aTe TefeTTeF to as
L
appToZ Xalue n)MO as tTansFuceT usuall[ consist of theT- theTOocaDle oT theTOocouple caDle
StTanFeF SoliF StTanFeF Oocouple, the connectinI line fToO the CoOpensatinI wiTes anF stTanFs of
15 OO2 15 OO2 022 OO2 connection point to the TefeTence Lunc- suDstitute materials that consist of
PVC tion, a TefeTence Lunction with a Mnown allo[s anF which aTe not iFentical to
teOpeTatuTe anF a XoltaIe OeasuTinI the associateF theTOocouple aTe calleF
coTe 135 138 115 FeXice coOpensatinI caDles
paiT The connectinI line Detween the theT- - 6uDstitute materials aTe useF foT the
scTeeneF 240 245 180 Oocouple anF the TefeTence Lunction T[pe . anF T[pe N theTOocouples
FEP Oust haXe the saOe theTOo-electTic - Precious metal thermocouples
pTopeTties as the theTOocouple itself T[pe 5, T[pe S, T[pe B consist of
coTe 0 0 45 The teOpeTatuTe FiffeTential is Oeas- theTOal OateTials
paiT uTeF Detween the OeasuTinI point anF
scTeeneF 120 120 70 the TefeTence Lunction ToleTance of the Thermocouple caDles
OeteT Tesistances q10 TheTOocouple caDles aTe OaFe of the
Silicone
saOe eleOent OateTial as the theTOo-
coTe 80 70 45 Hazardous areas couple anF aTe testeF to the saOe teO-
- Inductivity IuiFe Xalue The coOpensatinI caDles foT theTOo- peTatuTes :e offeT theTOocouple caDles
foT PVC, uoTpol[OeTs anF silicone couples with plastic insulation can De on custoOeT TeSuest onl[
XeTsions  1 O+MO iOpTinteF with lonIituFinal coloTeF
- Corrosiveness oH re gases stTipes FepenFinI on the t[pe of the Note
(halogen-free) theTOocouple, as follows TheTOal OateTials consist of XeT[ eZpen-
6ilicone  glass-Der CuCu-Ni DTown, )eCu-Ni FaTM siXe OateTials while the suDstitutes aTe
test in accoTFance with VDE 0472 PaTt Dlue, NiCTNi ITeen, Pt-5hPt white siInicantl[ cheapeT
13 anF IEC 0754-1 In the case of coOpensatinI caDles foT
No FeXelopOent of coTTosiXe Iases theTOocouples with OineTal insulation
oT with Oetal DTaiFinI, foT coloT coFinI
)ire Dehavior of the intTinsicall[ safe pTopeTt[, a liIht
Self-eZtinIuishinI anF aOe-TetaTFant Dlue DanF of sufcient wiFth Oust also
in accoTFance with VDE 042 322-1-2, De woXen in
DIN EN 0332-1-2IEC 0332-1
coTTesponFs to DIN VDE 0472 PaTt
04 test t[pe B

325
COLOR CODING AND TEMPERATURE RANGES FOR
T+ERMAL CABLES COMPENSATING CABLES

CoFe letteT of the MateTial


theTOocouple coODination NF C 42-324 BS 4937

IFentication IFentication
+ -
plus Oinus T+L AGL T+L AGL

T Cu Cu Ni TX TC TX
-25C to +100C -25C to +100C 0C to +100C

U Cu Cu Ni

J Fe Cu Ni JX JC JX
-25C to +200C -25C to +250C 0C to +200C

Fe Cu Ni
L

E
Ni Cr Cu Ni EX EC EX
-25C to +200C -25C to +250C 0C to +200C

Ni Cr Ni
KX KC KX
-25C to +200C -25C to +200C 0C to +200C

K
Ni Cr Ni WC
0C to +100C

Ni Cr Ni VC VX
0C to +100C 0C to +100C

N Ni Cr Si Ni Si

R PtRh 13 Pt
S PtRh 10 Pt SC SX
0C to +200C 0C to +200C

B PtRh 30 PtRh 6 BC
0C to +100C

The hiIhest application teOpeTatuTe of the insulatinI OateTials As a Tule, intTinsicall[ safe caDles haXe a Dlue LacMet coloT anF an
oT the application teOpeTatuTe TanIe of the conFuctoT OateTial iFentication stTipe assiIneF to the eleOent
liOits the application teOpeTatuTe TanIe of the caDle The loweT
Xalue is XaliF

32
ANSI MC 91 DIN IEC 584 DIN 43710*

IFentication IFentication IFentication


T+L AGL T+L AGL T+L AGL

TX TX
0C to +100C -25C to +100C

UX**
0C to +200C

JX JX**
0C to +200C -25C to +200C

LX**
0C to +200C
L
EX EX
0C to +200C -25C to +200C

KX KX
0C to +200C -25C to +200C

KCA**
0C to +150C

KCB
0C to +100C

NX NC
-25C to +200C 0C to +150C

RCA/SCA
0C to +100C
SX RCB/SCB**
0C to +200C 0C to +200C

AccoTFinI to
BX DIN 4371085 BC
0C to +100C 0C to +100C

THL = Thermocouple wire EZaOple .CA CoOpensatinI caDle .CA plus positiXe coTe foT AGL .C
$*L = Compensating caDle .CA Oinus neIatiXe coTe foT AGL .C
* DIN 43710 was withFTawn in ApTil 1994 Thus the eleOent t[pes U anF L aTe no lonIeT stanFaTFi\eF ** stanFaTF t[pe

327
COMPENSATING CABLES
MateTials foT coOpensatinI caDles

EleOent t[pe MateTial of the coOpensatinI caDle


StanFaTFs
T[pe Plus pole + Minus pole - CoFe Plus pole + Minus pole -
U Cu CuNi UX Cu CuNi
DIN 43710
L Fe CuNi LX Fe CuNi
T Cu CuNi TX Cu CuNi
E NiCT CuNi EX NiCT CuNi
J Fe CuNi JX Fe CuNi
. NiCT Ni .X NiCT Ni
DIN IEC 584
. NiCT Ni .C 1 Fe CuNi
. NiCT Ni .C 2 Cu CuNi
RS Pt 1310 Rh Pt RC ASC A Cu CuNi
RS Pt 1310 Rh Pt RC BSC B Cu CuNi
T Cu CuNi TX Cu CuNi
E NiCT CuNi EX NiCT CuNi
J Fe CuNi JX Fe CuNi
. NiCT Ni .X NiCT Ni
NF
. NiCT Ni VC Cu CuNi
. NiCT Ni :C Fe CuNi
RS Pt 1310 Rh Pt RCSC Cu CuNi
B Pt 30 Rh Pt  Rh BC Cu-AL< Cu
T Cu CuNi TX Cu CuNi
E NiCT CuNi EX NiCT CuNi
J Fe CuNi JX Fe CuNi
ANSI
. NiCT Ni .X NiCT Ni
RS Pt 1310 Rh Pt RXSX Cu CuNi
B Pt 30 Rh Pt  Rh BX Cu Cu

PTopeTties of the wiTes foT theTOocouples anF coOpensatinI caDles


Spec.
Densit[ at Resistance Xalue IuiFe Xalue
Main coOponents appToZ  Tesistance
20C in ohOO
MateTials at 20C
I
Cu Ni Mn OtheT ohO w cO OO 0.20 OO 1.38
cO3
CuNi 55 44 1 - 8.85 49 15.0 0.328
SoNi 51 45 2 Fe2 8.85 51 1.2 0.341
NiCT - Rest - CT 10 8.7 72 22.90 0.481
Ni - 95 MnAlSi 5 8.55 27 8.59 0.180
SoPt 95 3 2 - 8.9 12 3.82 0.0802
ECu In accoTFance with DIN 4 431 8.9 1.7 0.54 0.011
Fe - - - - 7.85 12 3.82 0.08
BPX 97 - 3 - 8.9 12.5 3.98 0.084

328
COMPENSATING CABLES

Te
71 TFa nt
3 nce

tu
43 o e

Ta

us
N cc leO

pe

C e
O

pe

Fi
n nI
t[

Ta
DI in a le e

et

.
oZ
n

tio Ta

oZ
e

cM

C te
io

: e nI
pl

pT
ith al p

la e

O pT
at

La
ou

su u T

e on
w teTi cou

Dl Fi
ap

M ap
ul

in Tat

ca en
oc

nI ti
in
s
.


aT Met
a o

Ta alla
in

MI Iht
no

Z .D
of pe
O

oT
O O

eT

TO
Te
pe
eT
eT

in
O

st
Tt

ut

ei
c
Co
Th

In
Fo
Pa

Th

O
Ja

Te
T[

O
Single-pair: 2 x 1.5 mm2 (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48001 FE-CuNi .o L AE 1 L stTanFeF PVC - 5.4 TounF 7.5 40
48002 SoNiCT-SoNi . AN 1 L stTanFeF PVC - 5.4 TounF stationaT[ 7.5 40
-25C to +70C
48003 SoPtRh-SoPt S AP 1 L stTanFeF PVC - 5.4 TounF -10C to +80C 7.5 40
eZinI
48230 Cu-CuNi .o U AC 1 L stTanFeF PVC - 5.4 TounF -5C to +70C 7.5 40
48478 Fe-CuNi J AF 1 L stTanFeF PVC - 5.4 TounF 7.5 40
48004 Fe-CuNi .o L AE 1 M stTanFeF PVC - 5.4 TounF stationaT[ 10 40
48005 SoNiCT-SoNi . AN 1 M stTanFeF PVC - 5.4 TounF -25C to +70C 10 40
-10C to +80C
4800 SoPtRh-SoPt S AP 1 M stTanFeF PVC - 5.4 TounF eZinI 10 40
48231 Cu-CuNi .o U AC 1 M stTanFeF PVC - 5.4 TounF -5C to +70C 10 40
48007 Fe-CuNi .o L AE 1 L-SIL stTanFeF silicone - 5.4 TounF stationaT[ 7.5 40
48008 SoNiCT-SoNi . AN 1 L-SIL stTanFeF silicone - 5.4 TounF -25C to +180C 7.5 40
-0C to +180C eZinI
48009 SoPtRh-SoPt S AP 1 L-SIL stTanFeF silicone - 5.4 TounF -25C to +180C 7.5 40
48232 Cu-CuNi .o U AC 1 L-SIL stTanFeF silicone - 5.4 TounF shoTt tiOe +200C 7.5 40
48233 Fe-CuNi .o L AE 2 M-SIL stTanFeF silicone 7.8 TounF stationaT[ 15 248
TeZtile tape -25C to +180C
48234 SoNiCT-SoNi . AN 2 M-SIL stTanFeF silicone 7.8 TounF 15 248
leaF sheath -0C to +180C eZinI
48235 SoPtRh-SoPt S AP 2 M-SIL stTanFeF silicone 7.8 TounF -25C to +180C 15 248
tin. steel wiTe DTaiF
4823 Cu-CuNi .o U AC 2 M-SIL stTanFeF silicone 7.8 TounF shoTt tiOe +200C 15 248
48010 Fe-CuNi .o L AE 3 L paTallel Ilass-DeT 5.0Z7.2 oXal stationaT[ 7.5 4
48011 SoNiCT-SoNi . AN 3 L paTallel Ilass-DeT 5.0Z7.2 oXal -25C to +200C 7.5 4
Ilass-DeT DTaiF -0C to +200C
48012 SoPtRh-SoPt S AP 3 L paTallel Ilass-DeT 5.0Z7.2 oXal eZinI -25C to 7.5 4
48237 Cu-CuNi .o U AC 3 L paTallel Ilass-DeT 5.0Z7.2 oXal +200C 7.5 4
48238 Fe-CuNi .o L AE 3 Ln-SIL paTallel silicone 5.2Z7.4 oXal stationaT[ 7.5 2
48239 SoNiCT-SoNi . AN 3 Ln-SIL paTallel silicone 5.2Z7.4 oXal -25C to +180C 7.5 2
silicone -0C to +180C eZinI
48240 SoPtRh-SoPt S AP 3 Ln-SIL paTallel silicone 5.2Z7.4 oXal -25C to +180C 7.5 2
48241 Cu-CuNi .o U AC 3 Ln-SIL paTallel silicone 5.2Z7.4 oXal shoTt tiOe +200C 7.5 2
48013 Fe-CuNi .o L AE 4 L paTallel Ilass-DeT 5.8Z8.0 oXal stationaT[ 7.5 87
48014 SoNiCT-SoNi . AN 4 L paTallel Ilass-DeT Glass-DeT DTaiF 5.8Z8.0 oXal -25C to +200C 7.5 87
-0C to +200C
48015
48242
SoPtRh-SoPt
Cu-CuNi .o
S
U
AP 4 L paTallel
AC 4 L paTallel
Ilass-DeT
Ilass-DeT
IalX. steel wiTe DTaiF 5.8Z8.0
5.8Z8.0
oXal
oXal
eZinI
-25C to +200C
7.5
7.5
87
87 L
4801 Fe-CuNi .o L AE 4 Ln-SIL silicone .0Z8.2 oXal stationaT[ 7.5 85
48017 SoNiCT-SoNi . AN 4 Ln-SIL silicone silicone .0Z8.2 oXal -25C to +180C 7.5 85
-0C to +180C fleZinI
48018 SoPtRh-SoPt S AP 4 Ln-SIL silicone IalX. steel wiTe DTaiF .0Z8.2 oXal -25C to +180C 7.5 85
48243 Cu-CuNi .o U AC 4 Ln-SIL silicone .0Z8.2 oXal shoTt tiOe +200C 7.5 85
48244 Fe-CuNi .o L AE 5 L PVC PETP tape 8.1 TounF stationaT[ 7.5 93
48245 SoNiCT-SoNi . AN 5 L PVC IalX. Cu-TounF 8.1 TounF -25C to +70C 7.5 93
-10C to +80C
4824 SoPtRh-SoPt S AP 5 L PVC wiTe DTaiF 8.1 TounF fleZinI 7.5 93
48247 Cu-CuNi .o U AC 5 L PVC PVC LacMet 8.1 TounF -5C to +70C 7.5 93
48248 Fe-CuNi .o L AE  L-SIL silicone 8.0 TounF stationaT[ 7.5 94
PETP tape -25C to +180C
48249 SoNiCT-SoNi . AN  L-SIL silicone 8.0 TounF 7.5 94
Dl. Cu-ITounF wiTe fleZinI
48250 SoPtRh-SoPt S AP  L-SIL silicone 8.0 TounF -0C to +180C 7.5 94
0.5 OO  -25C to +180C
48251 Cu-CuNi .o U AC  L-SIL silicone Alu tapesilicone 8.0 TounF shoTt tiOe 7.5 94
+200C
48252 Fe-CuNi .o L AE  M-SIL silicone PETP tape 7.8 TounF stationaT[ 12 92
48253 SoNiCT-SoNi . AN  M-SIL silicone Dl. Cu-ITounF wiTe 7.8 TounF -25C to +180C 12 92
-0C to +180C fleZinI
48254 SoPtRh-SoPt S AP  M-SIL silicone 0.5 OO  7.8 TounF -25C to +180C 12 92
48255 Cu-CuNi .o U AC  M-SIL silicone Alu tapesilicone 7.8 TounF shoTt tiOe +200C 12 92
48019 Fe-CuNi .o L AE 7 L paTallel PVC 5.5Z8.2 oXal stationaT[ 7.5 0
48020 SoNiCT-SoNi . AN 7 L paTallel PVC 5.5Z8.2 oXal -25C to +70C 7.5 0
Ilass-DeT -10C to +80C
48021 SoPtRh-SoPt S AP 7 L paTallel PVC 5.5Z8.2 oXal fleZinI 7.5 0
4825 Cu-CuNi .o U AC 7 L paTallel PVC 5.5Z8.2 oXal -5C to +70C 7.5 0
48022 Fe-CuNi .o L AE 8 L PVC .9Z9.0 oXal stationaT[ 7.5 82
48023 SoNiCT-SoNi . AN 8 L PVC Glass-fiDeT .9Z9.0 oXal -25C to +70C 7.5 82
-10C to +80C
48024 SoPtRh-SoPt S AP 8 L PVC IalX. steel wiTe DTaiF .9Z9.0 oXal fleZinI 7.5 82
48257 Cu-CuNi .o U AC 8 L PVC .9Z9.0 oXal -5C to +70C 7.5 82
48025 Fe-CuNi .o L AE 9 L PVC 7.0 TounF 7.5 79
4802 SoNiCT-SoNi . AN 9 L PVC 7.0 TounF stationaT[ 7.5 79
-25C to +70C
48027 SoPtRh-SoPt S AP 9 L PVC PVC 7.0 TounF -10C to +80 7.5 79
fleZinI
48258 Cu-CuNi .o U AC 9 L PVC 7.0 TounF -5C to +70C 7.5 79
48479 Fe-CuNi J AF 9 L PVC 7.0 TounF 7.5 79
48028 Fe-CuNi .o L AE 9-2 LS PVC 7.8 TounF 7.5 108
48029 SoNiCT-SoNi . AN 9-2 LS PVC 7.8 TounF stationaT[ 7.5 108
PVCIalX. -25C to +70C
48030 SoPtRh-SoPt S AP 9-2 LS PVC 7.8 TounF -10C to +80C 7.5 108
steel wiTe DTaiF fleZinI
48259 Cu-CuNi .o U AC 9-2 LS PVC 7.8 TounF -5C to +70C 7.5 108
48480 Fe-CuNi J AF 9-2 LS PVC 7.8 TounF 7.5 108
48031 Fe-CuNi .o L AE 9-2 LS< PVC 9.8 TounF stationaT[ 7.5 147
PVCIalX.
48032 SoNiCT-SoNi . AN 9-2 LS< PVC 9.8 TounF -25C to +70C 7.5 147
steel wiTe DTaiF -10C to +80C
4809 SoPtRh-SoPt S AP 9-2 LS< PVC 9.8 TounF fleZinI 7.5 147
PVC -5C to +70C
4820 Cu-CuNi .o U AC 9-2 LS< PVC 9.8 TounF 7.5 147
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF

329
COMPENSATING CABLES

Te
71 TFa nt
3 nce

tu
43 o e

Ta

us
N cc leO

pe

C e
O

pe

Fi
n nI
t[

Ta
DI in a le e

et

.
oZ
n

tio Ta

oZ
e

cM

C te
io

: e nI
pl

pT
ith al p

la e

O pT
at

La
ou

su uT

e on
w teTi cou

Dl Fi
ap

M ap
ul

in Tat

ca en
oc

nI ti
in
s
.


aT Met
a o

Ta alla
in

MI Iht
no

Z .D
of pe
O

oT
O O

eT

TO
Te
pe
eT
eT

in
O

st
Tt

ut

ei
c
Co
Th

In
Fo
Pa

Th

O
Ja

Te
T[

O
Single-pair: 2 x 1.5 mm2 (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48033 FE-CuNi .o L AE 9 M PVC 7.0 TounF stationaT[ 12 79
48034 SoNiCT-SoNi . AN 9 M PVC 7.0 TounF -25C to +70C 12 79
PVC -10C to +80
48035 SoPtRh-SoPt S AP 9 M PVC 7.0 TounF fleZinI 12 79
4821 Cu-CuNi .o U AC 9 M PVC 7.0 TounF -5C to +70C 12 79
4822 Fe-CuNi .o L AE 9-2 MS< PVC 9. TounF stationaT[ 12 144
PVCIalX.
4823 SoNiCT-SoNi . AN 9-2 MS< PVC 9. TounF -25C to +70C 12 144
steel wiTe DTaiF -10C to +80C
4824 SoPtRh-SoPt S AP 9-2 MS< PVC 9. TounF fleZinI 12 144
PVC -5C to +70C
4825 Cu-CuNi .o U AC 9-2 MS< PVC 9. TounF 12 144
4803 Fe-CuNi .o L AE 10 L-SIL paTallel silicone 5.5Z8.2 oXal stationaT[ 7.5 59
48037 SoNiCT-SoNi . AN 10 L-SIL paTallel silicone 5.5Z8.2 oXal -25C to +180C 7.5 59
Ilass-DeT -0C to +180C fleZinI
48038 SoPtRh-SoPt S AP 10 L-SIL paTallel silicone 5.5Z8.2 oXal -25C to +180C 7.5 59
482 Cu-CuNi .o U AC 10 L-SIL paTallel silicone 5.5Z8.2 oXal shoTt tiOe +200C 7.5 59
48039 Fe-CuNi .o L AE 11 L silicone .3Z9.0 oXal stationaT[ 7.5 82
48040 SoNiCT-SoNi . AN 11 L silicone Glass-fiDeT .3Z9.0 oXal -25C to +180C 7.5 82
-0C to +180C fleZinI
48041 SoPtRh-SoPt S AP 11 L silicone IalX. steel wiTe DTaiF .3Z9.0 oXal -25C to +180C 7.5 82
4827 Cu-CuNi .o U AC 11 L silicone .3Z9.0 oXal shoTt tiOe +200C 7.5 82
48042 Fe-CuNi .o L AE 11 LT silicone .7 TounF stationaT[ 7.5 83
48043 SoNiCT-SoNi . AN 11 LT silicone Glass-fiDeT .7 TounF -25C to +180C 7.5 83
-0C to +180C fleZinI
48044 SoPtRh-SoPt S AP 11 LT silicone IalX. steel wiTe DTaiF .7 TounF -25C to +180C 7.5 83
4828 Cu-CuNi .o U AC 11 LT silicone .7 TounF shoTt tiOe +200C 7.5 83
48045 Fe-CuNi .o L AE 11 MT silicone .5 TounF stationaT[ 12 83
4804 SoNiCT-SoNi . AN 11 MT silicone Glass-fiDeT .5 TounF -25C to +180C 12 83
-0C to +180C fleZinI
48047 SoPtRh-SoPt S AP 11 MT silicone IalX. steel wiTe DTaiF .5 TounF -25C to +180C 12 83
4829 Cu-CuNi .o U AC 11 MT silicone .5 TounF shoTt tiOe +200C 12 83
48048 Fe-CuNi .o L AE 12 L paTallel PVC 4.3Z7.0 oXal 7.5 9
48049 SoNiCT-SoNi . AN12 L paTallel PVC 4.3Z7.0 oXal stationaT[ 7.5 9
-25C to +70C
48050 SoPtRh-SoPt S AP 12 L paTallel PVC PVC 4.3Z7.0 oXal -10C to +80C 7.5 9
fleZinI
48270 Cu-CuNi .o U AC 12 L paTallel PVC 4.3Z7.0 oXal -5C to +70C 7.5 9
48481 Fe-CuNi J AF 12 L paTallel PVC 4.3Z7.0 oXal 7.5 9
48051 Fe-CuNi .o L AE 12 M paTallel PVC 4.2Z.8 oXal stationaT[ 12 1
48052 SoNiCT-SoNi . AN12 M paTallel PVC 4.2Z.8 oXal -25C to +70C 12 1
PVC -10C to +80C
48053 SoPtRh-SoPt S AP 12 M paTallel PVC 4.2Z.8 oXal fleZinI 12 1
48271 Cu-CuNi .o U AC 12 M paTallel PVC 4.2Z.8 oXal -5C to +70C 12 1
48054 Fe-CuNi .o L AE 13 L paTallel silicone 3.2Z5.9 oXal stationaT[ 7.5 45
48055 SoNiCT-SoNi . AN 13 L paTallel silicone 3.2Z5.9 oXal -25C to +180C 7.5 45
Glass-fiDeT -0C to +180C fleZinI
4805 SoPtRh-SoPt S AP 13 L paTallel silicone 3.2Z5.9 oXal -25C to +180C 7.5 45
48272 Cu-CuNi .o U AC 13 L paTallel silicone 3.2Z5.9 oXal shoTt tiOe +200C 7.5 45
48057 Fe-CuNi .o L AE 13 M silicone 3.5Z.0 oXal stationaT[ 12 45
48058 SoNiCT-SoNi . AN 13 M silicone 3.5Z.0 oXal -25C to +180C 12 45
Glass-fiDeT -0C to +180C fleZinI
48059 SoPtRh-SoPt S AP 13 M silicone 3.5Z.0 oXal -25C to +180C 12 45
48273 Cu-CuNi .o U AC 13 M silicone 3.5Z.0 oXal shoTt tiOe +200C 12 45
4800 Fe-CuNi .o L AE 14 L silicone Special foaOeF 11.7 TounF stationaT[ 7.5 19
4801 SoNiCT-SoNi . AN 14 L silicone silicone OiZtuTe 11.7 TounF -25C to +180C 7.5 19
-0C to +180C fleZinI
4802 SoPtRh-SoPt S AP 14 L silicone IalX. Steel hose 11.7 TounF -25C to +180C 7.5 19
48274 Cu-CuNi .o U AC 14 L silicone 11.7 TounF shoTt tiOe +200C 7.5 19
4803 Fe-CuNi .o L AE 15 L silicone 7.7 TounF 7.5 7
stationaT[
4804 SoNiCT-SoNi . AN 15 L silicone 7.7 TounF -25C to +180C 7.5 7
4805 SoPtRh-SoPt S AP 15 L silicone silicone 7.7 TounF -0C to +180C fleZinI 7.5 7
48275 Cu-CuNi .o U AC 15 L silicone 7.7 TounF -25C to +180C 7.5 7
shoTt tiOe +200C
48482 Fe-CuNi J AF 15 L silicone 7.7 TounF 7.5 7
480 Fe-CuNi .o L AE 15 LS silicone 7.8 TounF stationaT[ 7.5 105
4807 SoNiCT-SoNi . AN 15 LS silicone silicone 7.8 TounF -25C to +180C 7.5 105
-10C to +180C fleZinI
4808 SoPtRh-SoPt S AP 15 LS silicone IalX. steel wiTe DTaiF 7.8 TounF -25C to +180C 7.5 105
4827 Cu-CuNi .o U AC 15 LS silicone 7.8 TounF shoTt tiOe +200C 7.5 105
48277 Fe-CuNi .o L AE 1 L-SIL paTallel silicone 2.8Z5. oXal stationaT[ 7.5 38
48278 SoNiCT-SoNi . AN 1 L-SIL paTallel silicone 2.8Z5. oXal -25C to +180C 7.5 38
- -10C to +180C fleZinI
48279 SoPtRh-SoPt S AP 1 L-SIL paTallel silicone 2.8Z5. oXal -25C to +180C 7.5 38
48280 Cu-CuNi .o U AC 1 L-SIL paTallel silicone 2.8Z5. oXal shoTt tiOe +200C 7.5 38
48281 Fe-CuNi .o L AE 18 L +ELUFLON-FEP 4.4 TounF stationaT[ 7.5 37
48282 SoNiCT-SoNi . AN 18 L +ELUFLON-FEP 4.4 TounF -25C to +205C 7.5 37
+ELUFLON-FEP -100C to 200C
48283 SoPtRh-SoPt S AP 18 L +ELUFLON-FEP 4.4 TounF fleZinI 7.5 37
48284 Cu-CuNi .o U AC 18 L +ELUFLON-FEP 4.4 TounF -25C to +205C 7.5 37
48285 Fe-CuNi .o L AE 19 L +ELUFLON-FEP PETP tape 5. TounF stationaT[ 7.5 0
4828 SoNiCT-SoNi . AN 19 L +ELUFLON-FEP tin. Cu-TounF wiTe 5. TounF -25C to +205C 7.5 0
-100C to 200C
48287 SoPtRh-SoPt S AP 19 L +ELUFLON-FEP DTaiF 5. TounF fleZinI 7.5 0
48288 Cu-CuNi .o U AC 19 L +ELUFLON-FEP +ELUFLON-FEP 5. TounF -25C to +205C 7.5 0
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF

330
COMPENSATING CABLES

Te
71 TFa nt
3 nce

tu
43 o e

Ta

us
N cc leO

pe

C e
O

pe

Fi
n nI
t[

Ta
DI in a le e

et

.
oZ
n

tio Ta

oZ
e

cM

C te
io

: e nI
pl

pT
ith al p

la e

O pT
at

La
ou

su u T

e on
w teTi cou

Dl Fi
ap

M ap
ul

in Tat

ca en
oc

nI ti
in
s
.


aT Met
a o

Ta alla
in

MI Iht
no

Z .D
of pe
O

oT
O O

eT

TO
Te
pe
eT
eT

in
O

st
Tt

ut

ei
c
Co
Th

In
Fo
Pa

Th

O
Ja

Te
T[

O
Single-pair: 2 x 1.5 mm2 (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48289 FE-CuNi .o L AE 20 L PVC PETP tape 8.0 TounF stationaT[ 7.5 75
48290 SoNiCT-SoNi . AE 20 L PVC Dl. Cu-ITounF wiTe 8.0 TounF -25C to +70C 7.5 75
-10C to +80C
48291 SoPtRh-SoPt S AE 20 L PVC 0.5 OO  8.0 TounF fleZinI 7.5 75
48292 Cu-CuNi .o U AE 20 L PVC Alu-tapePVC 8.0 TounF -5C to +70C 7.5 75
48293 Fe-CuNi .o L AE 20 M PVC PETP tape 8.2 TounF stationaT[ 12 82
48294 SoNiCT-SoNi . AE 20 M PVC Dl. Cu-ITounF wiTe 8.2 TounF -25C to +70C 12 82
-10C to +80C
48295 SoPtRh-SoPt S AE 20 M PVC 0.5 OO  8.2 TounF fleZinI 12 82
4829 Cu-CuNi .o U AE 20 M PVC Alu-tapePVC 8.2 TounF -5C to +70C 12 82
Multiple-pair: 2 pair (4 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48100 Fe-CuNi .o L AE 9-4 L PVC 8.3 TounF 7.5 125
48101 SoNiCT-SoNi . AN 9-4 L PVC 8.3 TounF stationaT[ 7.5 125
-25C to +70C
48102 SoPtRh-SoPt S AP 9-4 L PVC PVC 8.3 TounF -10C to +80C 7.5 125
fleZinI
48297 Cu-CuNi .o U AC 9-4 L PVC 8.3 TounF -5C to +70C 7.5 125
48483 Fe-CuNi J AF 9-4 L PVC 8.3 TounF 7.5 125
48298 Fe-CuNi .o L AE 9-4 LS PVC 8.9 TounF stationaT[ 7.5 155
48299 SoNiCT-SoNi . AN 9-4 LS PVC PVC 8.9 TounF -25C to +70C 7.5 155
-10C to +80C
48300 SoPtRh-SoPt S AP 9-4 LS PVC IalX. steel wiTe DTaiF 8.9 TounF fleZinI 7.5 155
48301 Cu-CuNi .o U AC 9-4 LS PVC 8.9 TounF -5C to +70C 7.5 155
48137 Fe-CuNi .o L AE 9-4 LS< PVC 11.4 TounF stationaT[ 7.5 220
PVC
48138 SoNiCT-SoNi . AN 9-4 LS< PVC 11.4 TounF -25C to +70C 7.5 220
IalX. steel wiTe DTaiF -10C to +80C
48139 SoPtRh-SoPt S AP 9-4 LS< PVC 11.4 TounF fleZinI 7.5 220
PVC -5C to +70C
48302 Cu-CuNi .o U AC 9-4 LS< PVC 11.4 TounF 7.5 220
48303 Fe-CuNi .o L AE 9-4 MS< PVC 11.0 TounF stationaT[ 12 210
PVC
48304 SoNiCT-SoNi . AN 9-4 MS< PVC 11.0 TounF -25C to +70C 12 210
IalX. steel wiTe DTaiF -10C to +80C
48305 SoPtRh-SoPt S AP 9-4 MS< PVC 11.0 TounF fleZinI 12 210
PVC -5C to +70C
4830 Cu-CuNi .o U AC 9-4 MS< PVC 11.0 TounF 12 210
48307 Fe-CuNi .o L AE 20-4 M PVC PETP tape 10.8 TounF stationaT[ 12 137
48308 SoNiCT-SoNi
48309 SoPtRh-SoPt
. AN 20-4 M
S AP 20-4 M
PVC
PVC
Dl. Cu-ITounF wiTe 10.8
0.5 OO  10.8
TounF
TounF
-10C to +80C
-25C to +70C
fleZinI
12
12
137
137
L
48310 Cu-CuNi .o U AC 20-4 M PVC Alu-tapePVC 10.8 TounF -5C to +70C 12 137
Multiple-pair: 4 x 1.5 mm2 (L = stranded wire, conductor make-up 48 x 0.20 mm)
48474 Fe-CuNi .o L AE 11-4 LT silicone 7.8 TounF stationaT[ 7.5 11.8
48475 SoNiCT-SoNi . AE 11-4 LT silicone Glass-fiDeTIalX. steel 7.8 TounF -25C to +180C 7.5 11.8
-0C to +180C fleZinI
4847 SoPtRh-SoPt S AE 11-4 LT silicone wiTe DTaiF 7.8 TounF -25C to +180C 7.5 11.8
48477 Cu-CuNi .o U AE 11-4 LT silicone 7.8 TounF shoTt tiOe +200C 7.5 11.8
Multiple-pair: 3 pairs (6 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48103 Fe-CuNi .o L AE 9- L PVC 10.3 TounF 7.5 190
48104 SoNiCT-SoNi . AN 9- L PVC 10.3 TounF stationaT[ 7.5 190
-25C to +70C
48105 SoPtRh-SoPt S AP 9- L PVC PVC 10.3 TounF -10C to +80C 7.5 190
fleZinI
48311 Cu-CuNi .o U AC 9- L PVC 10.3 TounF -5C to +70C 7.5 190
48484 Fe-CuNi J AF 9- L PVC 10.3 TounF 7.5 190
48312 Fe-CuNi .o L AE 9- LS PVC 10.9 TounF stationaT[ 7.5 22
PVC
48313 SoNiCT-SoNi . AN 9- LS PVC 10.9 TounF -25C to +70C 7.5 2
IalX. steel wiTe DTaiF -10C to +80C
48314 SoPtRh-SoPt S AP 9- LS PVC 10.9 TounF fleZinI 7.5 22
48315 Cu-CuNi .o U AC 9- LS PVC 10.9 TounF -5C to +70C 7.5 22
48140 Fe-CuNi .o L AE 9- LS< PVC 13.4 TounF stationaT[ 7.5 292
PVC
48141 SoNiCT-SoNi . AN 9- LS< PVC 13.4 TounF -25C to +70C 7.5 292
IalX. steel wiTe DTaiF -10C to +80C
48142 SoPtRh-SoPt S AP 9- LS< PVC 13.4 TounF fleZinI 7.5 292
PVC -5C to +70C
4831 Cu-CuNi .o U AC 9- LS< PVC 13.4 TounF 7.5 292
48317 Fe-CuNi .o L AE 9- MS< PVC 12.5 TounF stationaT[ 12 272
PVC
48318 SoNiCT-SoNi . AN 9- MS< PVC 12.5 TounF -25C to +70C 12 272
IalX. steel wiTe DTaiF -10C to +80C
48319 SoPtRh-SoPt S AP 9- MS< PVC 12.5 TounF fleZinI 12 272
PVC -5C to +70C
48320 Cu-CuNi .o U AC 9- MS< PVC 12.5 TounF 12 272
48321 Fe-CuNi .o L AE 20- M PVC PETP tape 12.4 TounF stationaT[ 12 18
48322 SoNiCT-SoNi . AN 20- M PVC Dl. Cu-ITounF wiTe 12.4 TounF -25C to +70C 12 18
-10C to +80C
48323 SoPtRh-SoPt S AP 20- M PVC 0.5 OO  12.4 TounF fleZinI 12 18
48324 Cu-CuNi .o U AC 20- M PVC Alu-tapePVC 12.4 TounF -5C to +70C 12 18
Multiple-pair: 4 pairs (8 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm
4810 Fe-CuNi .o L AE 9-8 L PVC 11.0 TounF 7.5 238
48107 SoNiCT-SoNi . AN 9-8 L PVC 11.0 TounF stationaT[ 7.5 238
-25C to +70C
48108 SoPtRh-SoPt S AP 9-8 L PVC PVC 11.0 TounF -10C to +80C 7.5 238
fleZinI
48325 Cu-CuNi .o U AC 9-8 L PVC 11.0 TounF -5C to +70C 7.5 238
48485 Fe-CuNi J AF 9-8 L PVC 11.0 TounF 7.5 238
48143 Fe-CuNi .o L AE 9-8 LS< PVC 14.0 TounF stationaT[ 7.5 410
PVC
48144 SoNiCT-SoNi . AN 9-8 LS< PVC 14.0 TounF -25C to +70C 7.5 410
IalX. steel wiTe DTaiF -10C to +80C
48145 SoPtRh-SoPt S AP 9-8 LS< PVC 14.0 TounF fleZinI 7.5 410
PVC -5C to +70C
4832 Cu-CuNi .o U AC 9-8 LS< PVC 14.0 TounF 7.5 410
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF

331
COMPENSATING CABLES

Te
71 TFa nt
3 nce

tu
43 o e

Ta

us
N cc leO

pe

C e
O

pe

Fi
n nI
t[

Ta
DI in a le e

et

.
oZ
n

tio Ta

oZ
e

cM

C te
io

: e nI
pl

pT
ith al p

la e

O pT
at

La
ou

su uT

e on
w teTi cou

Dl Fi
ap

M ap
ul

in Tat

ca en
oc

nI ti
in
s
.


aT Met
a o

Ta alla
in

MI Iht
no

Z .D
of pe
O

oT
O O

eT

TO
Te
pe
eT
eT

in
O

st
Tt

ut

ei
c
Co
Th

In
Fo
Pa

Th

O
Ja

Te
T[

O
Multiple-pair: 5 pairs (10 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm
48109 FE-CuNi .o L AE 9-10 L PVC 13.0 TounF 7.5 284
48110 SoNiCT-SoNi . AN 9-10 L PVC 13.0 TounF stationaT[ 7.5 284
48111 SoPtRh-SoPt S AP 9-10 L PVC 13.0 TounF -10C to +80C -25C to +70C 7.5 284
PVC
fleZinI
48327 Cu-CuNi .o U AC 9-10 L PVC 13.0 TounF -5C to +70C 7.5 284
4848 FE-CuNi .o J AF 9-10 L PVC 13.0 TounF 7.5 284
4814 Fe-CuNi .o L AE 9-10 LS< PVC 1.5 TounF stationaT[ 7.5 475
PVC
48147 SoNiCT-SoNi . AN 9-10 LS< PVC 1.5 TounF -25C to +70C 7.5 475
IalX. steel wiTe DTaiF -10C to +80C
48148 SoPtRh-SoPt S AP 9-10 LS< PVC 1.5 TounF fleZinI 7.5 475
PVC -5C to +70C
48328 Cu-CuNi .o U AC 9-10 LS< PVC 1.5 TounF 7.5 475
Multiple-pair: 6 pairs (12 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48112 Fe-CuNi .o L AE 9-12 L PVC 13.5 TounF 7.5 320
48113 SoNiCT-SoNi . AN 9-12 L PVC 13.5 TounF stationaT[ 7.5 320
-25C to +70C
48114 SoPtRh-SoPt S AP 9-12 L PVC PVC 13.5 TounF -10C to +80C 7.5 320
fleZinI
48329 Cu-CuNi .o U AC 9-12 L PVC 13.5 TounF -5C to +70C 7.5 320
48487 Fe-CuNi J AF 9-12 L PVC 13.5 TounF 7.5 320
48330 Fe-CuNi .o L AE 9-12 LS PVC 14.2 TounF stationaT[ 7.5 384
48331 SoNiCT-SoNi . AN 9-12 LS PVC PVC 14.2 TounF -25C to +70C 7.5 384
-10C to +80C
48332 SoPtRh-SoPt S AP 9-12 LS PVC IalX. steel wiTe DTaiF 14.2 TounF fleZinI 7.5 384
48333 Cu-CuNi .o U AC 9-12 LS PVC 14.2 TounF -5C to +70C 7.5 384
48149 Fe-CuNi .o L AE 9-12 LS< PVC 17.5 TounF stationaT[ 7.5 483
PVC
48150 SoNiCT-SoNi . AN 9-12 LS< PVC 17.5 TounF -25C to +70C 7.5 483
IalX. steel wiTe DTaiF -10C to +80C
48151 SoPtRh-SoPt S AP 9-12 LS< PVC 17.5 TounF fleZinI 7.5 483
PVC -5C to +70C
48334 Cu-CuNi .o U AC 9-12 LS< PVC 17.5 TounF 7.5 483
48335 Fe-CuNi .o L AE 9-12 MS< PVC 1.5 TounF stationaT[ 12 478
PVC
4833 SoNiCT-SoNi . AN 9-12 MS< PVC 1.5 TounF -25C to +70C 12 478
IalX. steel wiTe DTaiF -10C to +80C
48337 SoPtRh-SoPt S AP 9-12 MS< PVC 1.5 TounF fleZinI 12 478
PVC -5C to +70C
48338 Cu-CuNi .o U AC 9-12 MS< PVC 1.5 TounF 12 478
48339 Fe-CuNi .o L AE 20-12 M PVC PETP tape 1.3 TounF stationaT[ 12 32
48340 SoNiCT-SoNi . AN 20-12 M PVC Dl. Cu-ITounF wiTe 1.3 TounF -25C to +70C 12 32
-10C to +80C
48341 SoPtRh-SoPt S AP 20-12 M PVC 0.5 OO  1.3 TounF fleZinI 12 32
48342 Cu-CuNi .o U AC 20-12 M PVC
Alu-tapePVC
1.3 TounF -5C to +70C 12 32
Multiple-pair: 7 pairs (14 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm
48115 Fe-CuNi .o L AE 9-14 L PVC 14.5 TounF 7.5 39
4811 SoNiCT-SoNi . AN 9-14 L PVC 14.5 TounF stationaT[ 7.5 39
-25C to +70C
48117 SoPtRh-SoPt S AP 9-14 L PVC PVC 14.5 TounF -10C to +80C 7.5 39
fleZinI
48343 Cu-CuNi .o U AC 9-14 L PVC 14.5 TounF -5C to +70C 7.5 39
48488 Fe-CuNi J AF 9-14 L PVC 14.5 TounF 7.5 39
48152 Fe-CuNi .o L AE 9-14 LS< PVC 18.5 TounF stationaT[ 7.5 40
48153 SoNiCT-SoNi . AN 9-14 LS< PVC PVC 18.5 TounF 7.5 40
-25C to +70C
IalX. steel wiTe DTaiF -10C to +80C
48154 SoPtRh-SoPt S AP 9-14 LS< PVC 18.5 TounF fleZinI 7.5 40
PVC -5C to +70C
48344 Cu-CuNi .o U AC 9-14 LS< PVC 18.5 TounF 7.5 40
Multiple-pair: 8 pairs (16 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48118 Fe-CuNi .o L AE 9-1 L PVC 15.1 TounF 7.5 419
48119 SoNiCT-SoNi . AN 9-1 L PVC 15.1 TounF stationaT[ 7.5 419
-25C to +70C
48120 SoPtRh-SoPt S AP 9-1 L PVC PVC 15.1 TounF -10C to +80C 7.5 419
fleZinI
48345 Cu-CuNi .o U AC 9-1 L PVC 15.1 TounF -5C to +70C 7.5 419
48489 Fe-CuNi J AF 9-1 L PVC 15.1 TounF 7.5 419
4834 Fe-CuNi .o L AE 9-1 LS PVC 1.1 TounF stationaT[ 7.5 495
PVC
48347 SoNiCT-SoNi . AN 9-1 LS PVC 1.1 TounF -25C to +70C 7.5 495
IalX. steel wiTe -10C to +80C
48348 SoPtRh-SoPt S AP 9-1 LS PVC 1.1 TounF fleZinI 7.5 495
DTaiF -5C to +70C
48349 Cu-CuNi .o U AC 9-1 LS PVC 1.1 TounF 7.5 495
48155 Fe-CuNi .o L AE 9-1 LS< PVC 19.3 TounF stationaT[ 7.5 23
PVCIalX.
4815 SoNiCT-SoNi . AN 9-1 LS< PVC 19.3 TounF -25C to +70C 7.5 23
steel wiTe DTaiF -10C to +80C
48157 SoPtRh-SoPt S AP 9-1 LS< PVC 19.3 TounF fleZinI 7.5 23
PVC -5C to +70C
48350 Cu-CuNi .o U AC 9-1 LS< PVC 19.3 TounF 7.5 23
48351 Fe-CuNi .o L AE 9-1 MS< PVC 18.7 TounF stationaT[ 12 1
PVCIalX.
48352 SoNiCT-SoNi . AN 9-1 MS< PVC 18.7 TounF -25C to +70C 12 1
steel wiTe DTaiF -10C to +80C
48353 SoPtRh-SoPt S AP 9-1 MS< PVC 18.7 TounF fleZinI 12 1
PVC -5C to +70C
48354 Cu-CuNi .o U AC 9-1 MS< PVC 18.7 TounF 12 1
48355 Fe-CuNi .o L AE 20-1 M PVC PETP tape 1.8 TounF stationaT[ 12 423
4835 SoNiCT-SoNi . AN 20-1 M PVC Dl. Cu-ITounF wiTe 1.8 TounF -25C to +70C 12 423
-10C to +80C
48357 SoPtRh-SoPt S AP 20-1 M PVC 0.5 OO  1.8 TounF fleZinI 12 423
48358 Cu-CuNi .o U AC 20-1 M PVC
Alu-tapePVC
1.8 TounF -5C to +70C 12 423
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF

332
COMPENSATING CABLES

Te
71 TFa nt
3 nce

tu
43 o e

Ta

us
N cc leO

pe

C e
O

pe

Fi
n nI
t[

Ta
DI in a le e

et

.
oZ
n

tio Ta

oZ
e

cM

C te
io

: e nI
pl

pT
ith al p

la e

O pT
at

La
ou

su u T

e on
w teTi cou

Dl Fi
ap

M ap
ul

in Tat

ca en
oc

nI ti
in
s
.


aT Met
a o

Ta alla
in

MI Iht
no

Z .D
of pe
O

oT
O O

eT

TO
Te
pe
eT
eT

in
O

st
Tt

ut

ei
c
Co
Th

In
Fo
Pa

Th

O
Ja

Te
T[

O
Multiple-pair: 9 pairs (18 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm
48121 FE-CuNi .o L AE 9-18 L PVC 1.5 TounF 7.5 480
stationaT[
48122 SoNiCT-SoNi . AE 9-18 L PVC 1.5 TounF 7.5 480
-25C to +70C
48123 SoPtRh-SoPt S AE 9-18 L PVC PVC 1.5 TounF -10C to +80C 7.5 480
fleZinI
48359 Cu-CuNi .o U AE 9-18 L PVC 1.5 TounF 7.5 480
-5C to +70C
48490 FE-CuNi J AF 9-18 L PVC 1.5 TounF 7.5 480
48158 Fe-CuNi .o L AE 9-18 LS< PVC 20.5 TounF stationaT[ 7.5 758
PVC
48159 SoNiCT-SoNi . AE 9-18 LS< PVC 20.5 TounF -25C to +70C 7.5 758
IalX. steel wiTe DTaiF -10C to +80C
4810 SoPtRh-SoPt S AE 9-18 LS< PVC 20.5 TounF fleZinI 7.5 758
PVC
4830 Cu-CuNi .o U AE 9-18 LS< PVC 20.5 TounF -5C to +70C 7.5 758
Multiple-pair: 10 pairs (20 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48124 Fe-CuNi .o L AE 9-20 L PVC 1.7 TounF 7.5 520
stationaT[
48125 SoNiCT-SoNi . AN 9-20 L PVC 1.7 TounF 7.5 520
-25C to +70C
4812 SoPtRh-SoPt S AP 9-20 L PVC PVC 1.7 TounF -10C to +80C 7.5 520
fleZinI
4831 Cu-CuNi .o U AC 9-20 L PVC 1.7 TounF 7.5 520
-5C to +70C
48491 Fe-CuNi J AF 9-20 L PVC 1.7 TounF 7.5 520
4832 Fe-CuNi .o L AE 9-20 LS PVC 17.7 TounF stationaT[ 7.5 13
4833 SoNiCT-SoNi . AN 9-20 LS PVC PVC 17.7 TounF -25C to +70C 7.5 13
-10C to +80C
4834 SoPtRh-SoPt S AP 9-20 LS PVC IalX. steel wiTe DTaiF 17.7 TounF fleZinI 7.5 13
4835 Cu-CuNi .o U AC 9-20 LS PVC 17.7 TounF -5C to +70C 7.5 13
4811 Fe-CuNi .o L AE 9-20 LS< PVC 20.9 TounF stationaT[ 7.5 752
PVC
4812 SoNiCT-SoNi . AN 9-20 LS< PVC 20.9 TounF -25C to +70C 7.5 752
IalX. steel wiTe DTaiF -10C to +80C
4813 SoPtRh-SoPt S AP 9-20 LS< PVC 20.9 TounF fleZinI 7.5 752
PVC
483 Cu-CuNi .o U AC 9-20 LS< PVC 20.9 TounF -5C to +70C 7.5 752
4837 Fe-CuNi .o L AE 9-20 MS< PVC 20.3 TounF stationaT[ 12 744
PVC
4838 SoNiCT-SoNi . AN 9-20 MS< PVC 20.3 TounF -25C to +70C 12 744
IalX. steel wiTe DTaiF -10C to +80C
4839 SoPtRh-SoPt S AP 9-20 MS< PVC 20.3 TounF fleZinI 12 744
PVC
48370 Cu-CuNi .o U AC 9-20 MS< PVC 20.3 TounF -5C to +70C 12 744
48371 Fe-CuNi .o
48372 SoNiCT-SoNi
L AE 20-20 M
. AN 20-20 M
PVC
PVC
PETP tape
Dl. Cu-ITounF wiTe 20.3
20.3 TounF
TounF
-10C to +80C
stationaT[
-25C to +70C
12
12
542
542 L
48373 SoPtRh-SoPt S AP 20-20 M PVC 0.5 OO  20.3 TounF fleZinI 12 542
48374 Cu-CuNi .o U AC 20-20 M PVC Alu-tapePVC 20.3 TounF -5C to +70C 12 542
Multiple-pair: 12 pairs (24 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48127 Fe-CuNi .o L AE 9-24 L PVC 19.0 TounF 7.5 14
stationaT[
48128 SoNiCT-SoNi . AN 9-24 L PVC 19.0 TounF 7.5 14
-25C to +70C
48129 SoPtRh-SoPt S AP 9-24 L PVC PVC 19.0 TounF -10C to +80C 7.5 14
fleZinI
48375 Cu-CuNi .o U AC 9-24 L PVC 19.0 TounF 7.5 14
-5C to +70C
48492 Fe-CuNi J AF 9-24 L PVC 19.0 TounF 7.5 14
4837 Fe-CuNi .o L AE 9-24 LS PVC 20.2 TounF stationaT[ 7.5 738
48377 SoNiCT-SoNi . AN 9-24 LS PVC PVC 20.2 TounF -25C to +70C 7.5 738
-10C to +80C
48378 SoPtRh-SoPt S AP 9-24 LS PVC IalX. steel wiTe DTaiF 20.2 TounF fleZinI 7.5 738
48379 Cu-CuNi .o U AC 9-24 LS PVC 20.2 TounF -5C to +70C 7.5 738
4814 Fe-CuNi .o L AE 9-24 LS< PVC 24.2 TounF stationaT[ 7.5 938
PVC
4815 SoNiCT-SoNi . AN 9-24 LS< PVC 24.2 TounF -25C to +70C 7.5 938
IalX. steel wiTe DTaiF -10C to +80C
481 SoPtRh-SoPt S AP 9-24 LS< PVC 24.2 TounF fleZinI 7.5 938
PVC
48380 Cu-CuNi .o U AC 9-24 LS< PVC 24.2 TounF -5C to +70C 7.5 938
48381 Fe-CuNi .o L AE 9-24 MS< PVC 23.1 TounF stationaT[ 12 907
PVC
48382 SoNiCT-SoNi . AN 9-24 MS< PVC 23.1 TounF -25C to +70C 12 907
IalX. steel wiTe DTaiF -10C to +80C
48383 SoPtRh-SoPt S AP 9-24 MS< PVC 23.1 TounF fleZinI 12 907
PVC
48384 Cu-CuNi .o U AC 9-24 MS< PVC 23.1 TounF -5C to +70C 12 907
48385 Fe-CuNi .o L AE 20-24 M PVC PETP tape 22.5 TounF stationaT[ 12 38
4838 SoNiCT-SoNi . AN 20-24 M PVC Dl. Cu-ITounF wiTe 22.5 TounF -25C to +70C 12 38
-10C to +80C
48387 SoPtRh-SoPt S AP 20-24 M PVC 0.5 OO  22.5 TounF fleZinI 12 38
48388 Cu-CuNi .o U AC 20-24 M PVC Alu-tapePVC 22.5 TounF -5C to +70C 12 38
Multiple-pair: 16 pairs (32 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48389 Fe-CuNi .o L AE 9-32 L PVC 20.9 TounF 7.5 793
48390 SoNiCT-SoNi . AN 9-32 L PVC 20.9 TounF stationaT[ 7.5 793
-25C to +70C
48391 SoPtRh-SoPt S AP 9-32 L PVC PVC 20.9 TounF -10C to +80C 7.5 793
fleZinI
48392 Cu-CuNi .o U AC 9-32 L PVC 20.9 TounF 7.5 793
-5C to +70C
48493 Fe-CuNi J AF 9-32 L PVC 20.9 TounF 7.5 793
48393 Fe-CuNi .o L AE 9-32 LS PVC 22.1 TounF stationaT[ 7.5 923
48394 SoNiCT-SoNi . AN 9-32 LS PVC PVC 22.1 TounF -25C to +70C 7.5 923
-10C to +80C
48395 SoPtRh-SoPt S AP 9-32 LS PVC IalX. steel wiTe DTaiF 22.1 TounF fleZinI 7.5 923
4839 Cu-CuNi .o U AC 9-32 LS PVC 22.1 TounF -5C to +70C 7.5 923
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF

333
COMPENSATING CABLES

Te
71 TFa nt
3 nce

tu
43 o e

Ta

us
N cc leO

pe

C e
O

pe

Fi
n nI
t[

Ta
DI in a le e

et

.
oZ
n

tio Ta

oZ
e

cM

C te
io

: e nI
pl

pT
ith al p

la e

O pT
at

La
ou

su uT

e on
w teTi cou

Dl Fi
ap

M ap
ul

in Tat

ca en
oc

nI ti
in
s
.


aT Met
a o

Ta alla
in

MI Iht
no

Z .D
of pe
O

oT
O O

eT

TO
Te
pe
eT
eT

in
O

st
Tt

ut

ei
c
Co
Th

In
Fo
Pa

Th

O
Ja

Te
T[

O
Multiple-pair: 16 pairs (32 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48397 FE-CuNi .o L AE 9-32 LS< PVC 2.1 TounF stationaT[ 7.5 1141
PVC
48398 SoNiCT-SoNi . AN 9-32 LS< PVC 2.1 TounF -25C to +70C 7.5 1141
IalX. steel wiTe DTaiF -10C to +80C
48399 SoPtRh-SoPt S AP 9-32 LS< PVC 2.1 TounF fleZinI 7.5 1141
PVC -5C to +70C
48400 Cu-CuNi .o U AC 9-32 LS< PVC 2.1 TounF 7.5 1141
48401 Fe-CuNi .o L AE 9-32 MS< PVC 25.3 TounF stationaT[ 12 1130
PVC
48402 SoNiCT-SoNi . AN 9-32 MS< PVC 25.3 TounF -25C to +70C 12 1130
IalX. steel wiTe DTaiF -10C to +80C
48403 SoPtRh-SoPt S AP 9-32 MS< PVC 25.3 TounF fleZinI 12 1130
PVC -5C to +70C
48404 Cu-CuNi .o U AC 9-32 MS< PVC 25.3 TounF 12 1130
48405 Fe-CuNi .o L AE 20-32 M PVC PETP-tape 25.1 TounF stationaT[ 12 847
4840 SoNiCT-SoNi . AN 20-32 M PVC Dl. Cu-ITounF wiTe 25.1 TounF -25C to +70C 12 847
-10C to +80C
48407 SoPtRh-SoPt S AP 20-32 M PVC 0.5 OO  25.1 TounF fleZinI 12 847
48408 Cu-CuNi .o U AC 20-32 M PVC Alu-tapePVC 25.1 TounF -5C to +70C 12 847
Multiple-pair: 18 pair (36 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48130 Fe-CuNi .o L AE 9-3 L PVC 22.1 TounF 7.5 904
48132 SoNiCT-SoNi . AN 9-3 L PVC 22.1 TounF stationaT[ 7.5 904
-25C to +70C
48133 SoPtRh-SoPt S AP 9-3 L PVC PVC 22.1 TounF -10C to +80C 7.5 904
fleZinI
48409 Cu-CuNi .o U AC 9-3 L PVC 22.1 TounF -5C to +70C 7.5 904
48494 Fe-CuNi J AF 9-3 L PVC 22.1 TounF 7.5 904
48410 Fe-CuNi .o L AE 9-3 LS PVC 23.3 TounF stationaT[ 7.5 1040
PVC
48411 SoNiCT-SoNi . AN 9-3 LS PVC 23.3 TounF -25C to +70C 7.5 1040
IalX. steel wiTe -10C to +80C
48412 SoPtRh-SoPt S AP 9-3 LS PVC 23.3 TounF fleZinI 7.5 1040
DTaiF -5C to +70C
48413 Cu-CuNi .o U AC 9-3 LS PVC 23.3 TounF 7.5 1040
4817 Fe-CuNi .o L AE 9-3 LS< PVC 27.3 TounF stationaT[ 7.5 128
PVC
4819 SoNiCT-SoNi . AN 9-3 LS< PVC 27.3 TounF -25C to +70C 7.5 128
IalX. steel wiTe DTaiF -10C to +80C
48170 SoPtRh-SoPt S AP 9-3 LS< PVC 27.3 TounF fleZinI 7.5 128
PVC -5C to +70C
48414 Cu-CuNi .o U AC 9-3 LS< PVC 27.3 TounF 7.5 128
48415 Fe-CuNi .o L AE 9-3 MS< PVC 2.1 TounF stationaT[ 12 1232
PVC
4841 SoNiCT-SoNi . AN 9-3 MS< PVC 2.1 TounF -25C to +70C 12 1232
IalX. steel wiTe DTaiF -10C to +80C
48417 SoPtRh-SoPt S AP 9-3 MS< PVC 2.1 TounF fleZinI 12 1232
PVC -5C to +70C
48418 Cu-CuNi .o U AC 9-3 MS< PVC 2.1 TounF 12 1232
48419 Fe-CuNi .o L AE 20-3 M PVC PETP-tape 2.0 TounF stationaT[ 12 944
48420 SoNiCT-SoNi . AN 20-3 M PVC Dl. Cu-ITounF wiTe 2.0 TounF -25C to +70C 12 944
-10C to +80C
48421 SoPtRh-SoPt S AP 20-3 M PVC 0.5 OO  2.0 TounF fleZinI 12 944
48422 Cu-CuNi .o U AC 20-3 M PVC Alu-tapePVC 2.0 TounF -5C to +70C 12 944
Multiple-pair: 19 pairs (38 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm)
48134 Fe-CuNi .o L AE 9-38 L PVC 22.5 TounF stationaT[ 7.5 937
48135 SoNiCT-SoNi . AN 9-38 L PVC 22.5 TounF -25C to +70C 7.5 937
PVC -10C to +80C
4813 SoPtRh-SoPt S AP 9-38 L PVC 22.5 TounF fleZinI 7.5 937
48423 Cu-CuNi .o U AC 9-38 L PVC 22.5 TounF -5C to +70C 7.5 937
48171 Fe-CuNi .o L AE 9-38 LS< PVC 2.5 TounF stationaT[ 7.5 1340
PVC
48172 SoNiCT-SoNi . AN 9-38 LS< PVC 2.5 TounF -25C to +70C 7.5 1340
IalX. steel wiTe DTaiF -10C to +80C
48173 SoPtRh-SoPt S AP 9-38 LS< PVC 2.5 TounF fleZinI 7.5 1340
PVC -5C to +70C
48424 Cu-CuNi .o U AC 9-38 LS< PVC 2.5 TounF 7.5 1340
Multiple-pair: 20 pairs (40 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48425 Fe-CuNi .o L AE 9-40 L PVC 24.1 TounF stationaT[ 7.5 1032
4842 SoNiCT-SoNi . AN 9-40 L PVC 24.1 TounF -25C to +70C 7.5 1032
PVC -10C to +80C
48427 SoPtRh-SoPt S AP 9-40 L PVC 24.1 TounF fleZinI 7.5 1032
48428 Cu-CuNi .o U AC 9-40 L PVC 24.1 TounF -5C to +70C 7.5 1032
48429 Fe-CuNi .o L AE 9-40 LS PVC 25.3 TounF stationaT[ 7.5 1200
48430 SoNiCT-SoNi . AN 9-40 LS PVC PVC 25.3 TounF -25C to +70C 7.5 1200
-10C to +80C
48431 SoPtRh-SoPt S AP 9-40 LS PVC IalX. steel wiTe DTaiF 25.3 TounF fleZinI 7.5 1200
48432 Cu-CuNi .o U AC 9-40 LS PVC 25.3 TounF -5C to +70C 7.5 1200
48433 Fe-CuNi .o L AE 9-40 LS< PVC 29.3 TounF stationaT[ 7.5 144
PVC
48434 SoNiCT-SoNi . AN 9-40 LS< PVC 29.3 TounF -25C to +70C 7.5 144
IalX. steel wiTe DTaiF -10C to +80C
48435 SoPtRh-SoPt S AP 9-40 LS< PVC 29.3 TounF fleZinI 7.5 144
PVC -5C to +70C
4843 Cu-CuNi .o U AC 9-40 LS< PVC 29.3 TounF 7.5 144
48437 Fe-CuNi .o L AE 9-40 MS< PVC 28.0 TounF stationaT[ 12 1381
PVC
48438 SoNiCT-SoNi . AN 9-40 MS< PVC 28.0 TounF -25C to +70C 12 1381
IalX. steel wiTe DTaiF -10C to +80C
48439 SoPtRh-SoPt S AP 9-40 MS< PVC 28.0 TounF fleZinI 12 1381
PVC -5C to +70C
48440 Cu-CuNi .o U AC 9-40 MS< PVC 28.0 TounF 12 1381
48441 Fe-CuNi .o L AE 9-40M PVC PETP-tape 2.0 TounF stationaT[ 12 1001
48442 SoNiCT-SoNi . AN 9-40 M PVC Dl. Cu-ITounF wiTe 2.0 TounF -25C to +70C 12 1001
-10C to +80C
48443 SoPtRh-SoPt S AP 9-40 M PVC 0.5 OO Alu-tape 2.0 TounF fleZinI 12 1001
48444 Cu-CuNi .o U AC 9-40 M PVC PVC 2.0 TounF -5C to +70C 12 1001
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF

334
COMPENSATING CABLES

Te
71 TFa nt
3 nce

tu
43 o e

Ta

us
N cc leO

pe

C e
O

pe

Fi
n nI
t[

Ta
DI in a le e

et

.
oZ
n

tio Ta

oZ
e

cM

C te
io

: e nI
pl

pT
ith al p

la e

O pT
at

La
ou

su u T

e on
w teTi cou

Dl Fi
ap

M ap
ul

in Tat

ca en
oc

nI ti
in
s
.


aT Met
a o

Ta alla
in

MI Iht
no

Z .D
of pe
O

oT
O O

eT

TO
Te
pe
eT
eT

in
O

st
Tt

ut

ei
c
Co
Th

In
Fo
Pa

Th

O
Ja

Te
T[

O
Single-pair: 2 x 0.22 mm2 (L = stranded wire, conductor make-up 7 x 0.20 mm)
48200 FE-CuNi .o L AE 1 L PVC 1.0 TounF stationaT[ 7.5 10
48201 SoNiCT-SoNi . AE 1 L PVC 1.0 TounF -25C to +70C 7.5 10
- -10C to +80C
48202 SoPtRh-SoPt S AE 1 L PVC 1.0 TounF fleZinI 7.5 10
4840 Cu-CuNi .o U AE 1 L PVC 1.0 TounF -5C to +70C 7.5 10
Single-pair: 2 x 0.22 mm2 (L = stranded wire, conductor make-up 7 x 0.20 mm)
48203 Fe-CuNi .o L AE 9-022 PVC 4.0 TounF stationaT[ 7.5 22
48204 SoNiCT-SoNi . AE 9-022 PVC 4.0 TounF -25C to +70C 7.5 22
PVC -10C to +80C
48205 SoPtRh-SoPt S AE 9-022 PVC 4.0 TounF fleZinI 7.5 22
4841 Cu-CuNi .o U AE 9-022 PVC 4.0 TounF -5C to +70C 7.5 22
4820 Fe-CuNi .o L AE 5-022 PVC PETP tape 4.9 TounF stationaT[ 7.5 31
48207 SoNiCT-SoNi . AN 5-022 PVC IalX. Cu-TounF 4.9 TounF -25C to +70C 7.5 31
-10C to +80C
48208 SoPtRh-SoPt S AP 5-022 PVC wiTe DTaiF 4.9 TounF fleZinI 7.5 31
4842 Cu-CuNi .o U AC 5-022 PVC PVC 4.9 TounF -5C to +70C 7.5 31
4843 Fe-CuNi .o L AE 15-022 Ilass-DeT 3.4 TounF stationaT[ 7.5 1
4844 SoNiCT-SoNi . AN 15-022 Ilass-DeT 3.4 TounF -25C to +180C 7.5 1
fleZinI
4845 SoPtRh-SoPt S AP 15-022 Ilass-DeT silicone 3.4 TounF -40C to +200C 7.5 1
-25C to +180C
484 Cu-CuNi .o U AC 15-022 Ilass-DeT 3.4 TounF shoTt tiOe 7.5 1
+200C
48209 Fe-CuNi .o L AE 15-G 022 Ilass-DeT 3.9 TounF stationaT[ 7.5 22
48210 SoNiCT-SoNi . AN 15-G 022 Ilass-DeT 3.9 TounF -25C to +180C 7.5 22
fleZinI
48211 SoPtRh-SoPt S AP 15-G 022 Ilass-DeT siliconeIlass-fiDeT 3.9 TounF -40C to +200C 7.5 22
-25C to +180C
4847 Cu-CuNi .o U AC 15-G 022 Ilass-DeT 3.9 TounF shoTt tiOe 7.5 22
+200C
48212 Fe-CuNi .o L AE GI-SIL-GI-S Ilass-DeT 5.0 TounF stationaT[ 7.5 25
silicone -25C to +180C
48213 SoNiCT-SoNi . AN GI-SIL-GI-S Ilass-DeT 5.0 TounF 7.5 25
Glass-fiDeT -40C to +200C fleZinI
48214 SoPtRh-SoPt S AP GI-SIL-GI-S Ilass-DeT 5.0 TounF -25C to +180C 7.5 25
IalX. steel wiTe DTaiF
4848 Cu-CuNi .o U AC GI-SIL-GI-S Ilass-DeT 5.0 TounF shoTt tiOe +200C 7.5 25
Single-pair: 2 x 0.5 mm2 (L = stranded wire, conductor make-up 16 x 0.20 mm)
48215 Fe-CuNi .o
4821 SoNiCT-SoNi
L AE GI-SIL
. AN GI-SIL
Ilass-DeT
Ilass-DeT
4.
4.
TounF
TounF
stationaT[
-25C to +200C
7.5
7.5
18
18
L
silicone -40C to +200C
48217 SoPtRh-SoPt S AP GI-SIL Ilass-DeT 4. TounF fleZinI 7.5 18
4849 Cu-CuNi .o U AC GI-SIL Ilass-DeT 4. TounF -25C to +200C 7.5 18
Single-pair: 2 x 0.75 mm2 (L = stranded wire, conductor make-up 24 x 0.20 mm)
48218 Fe-CuNi .o L AE PVC-PVC PVC .0 TounF stationaT[ 7.5 25
48219 SoNiCT-SoNi . AN PVC-PVC PVC .0 TounF -25C to +70C 7.5 25
PVC -10C to +80C
48220 SoPtRh-SoPt S AP PVC-PVC PVC .0 TounF fleZinI 7.5 25
48470 Cu-CuNi .o U AC PVC-PVC PVC .0 TounF -5C to +70C 7.5 25
Multiple-pair: 4 x 0.22 mm2 (stranded wire, conductor make-up 7 x 0.20 mm)
48221 Fe-CuNi .o L AE PVC-PVC PVC .0 TounF stationaT[ 7.5 33
48222 SoNiCT-SoNi . AN PVC-PVC PVC .0 TounF -20C to +80C 7.5 33
PVC -10C to +80C
48223 SoPtRh-SoPt S AP PVC-PVC PVC .0 TounF fleZinI 7.5 33
48471 Cu-CuNi .o U AC PVC-PVC PVC .0 TounF -5C to +80C 7.5 33
48224 Fe-CuNi .o L AE PVC-C-PVC PVC .0 TounF stationaT[ 7.5 37
IalX.
48225 SoNiCT-SoNi . AN PVC-C-PVC PVC .0 TounF -20C to +80C 7.5 37
Cu-DTaiF -10C to +80C
4822 SoPtRh-SoPt S AP PVC-C-PVC PVC .0 TounF fleZinI 7.5 37
PVC LacMet
48472 Cu-CuNi .o U AC PVC-C-PVC PVC .0 TounF -5C to +80C 7.5 37
48227 Fe-CuNi .o L AE GIL-SIL Ilass-DeT .0 TounF stationaT[ 7.5 35
48228 SoNiCT-SoNi . AN GIL-SIL Ilass-DeT .0 TounF -25C to +180C 7.5 35
silicone -40C to +200C
48229 SoPtRh-SoPt S AP GIL-SIL Ilass-DeT .0 TounF fleZinI 7.5 35
48473 Cu-CuNi .o U AC GIL-SIL Ilass-DeT .0 TounF -25C to +180C 7.5 35
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF

335
COAXIAL CABLES

Description Properties Page

RG-Coaxial Cables 338

RG-Coaxial Cables 339

RG-Coaxial Cables 340

Halogen-Free RG-Coaxial Cables 341

CATV-Cables 342

SAT-Coaxial Cables up to 2150 MHz, for satellite-receivers, double screened 343

Multimedia-Coaxial Cables SAT 1,0/4,6GH, up to 2400MHz, for digital-tv, double screened, screening efficieny >90dB 344

SAT-Coaxial Cables for digital-tv, screening efficieny >90dB / >95dB, for satellite-receivers, double screened 345

RGB-COAX-CY / RGB-COAX-(St)Y transmission cables for colour monitor 346

337
Coaxial Cables

RG-Coaxial Cables

Type RG 6 A/U RG 11 A/U RG 58 C/U RG 59 B/U RG 62 A/U RG 71 B/U


Part no. 40001 40002 40003 40004 40005 40006

Cable structure
Inner conductor diameter mm 1 x 0,7 7 x 0,4 19 x 0,2 1 x 0,6 1 x 0,6 1 x 0,6
Steel/copper, bare Tinned copper Tinned copper Steel/copper, bare Steel/copper, bare Steel/copper, bare
Insulation mm 4,7 PE 7,3 PE 2,95 PE 3,7 PE 3,7 PE, hollow 3,7 PE, hollow
Outer conductor 2 braids Braid Braid Braid Braid 2 braids
Silvered copper Copper, bare Tinned copper Copper, bare Copper, bare Copper, bare
Copper, bare - - - - Tinned copper
Outer sheath PVC PVC PVC PVC PVC PVC
Min. bending radius approx. mm 40 50 25 30 30 30
Temperature range C -35 to +80 -35 to +80 -35 to +80 -35 to +80 -35 to +80 -50 to +70
Copper weight kg/km 72,0 58,0 29,0 28,0 28,0 48,0
Outer approx. mm 8,4 10,3 5,0 6,2 6,2 6,2
Weight approx. kg / km 115 140 38 57 52 62

Electrical characteristics
Impedance (Ohm) 75 3 75 3 50 2 75 3 93 5 93 3
Frequency range
f (max.) GHz 3 3 3 3 3 3
Propagation velocity v/c 0,7 0,7 0,7 0,7 0,8 0,8
Attenuation at 20C
(db/100m)
100 MHz 8,8 7,5 17 11,5 10,5 10,5
200 MHz 13,5 11 24 16,5 15 15
500 MHz 21 18,5 39 27 24,5 24,5
800 MHz 27,5 24 51 35 32,5 32,5
1000 MHz - 30 56 41 35 -
1350 MHz - - - - - -
1750 MHz - - - - - -
CapacitancepF/m 67 67 101 67 42,5 42,5
Rel. velocity of propagation % 67 67 67 67 83 83
Insulation resistance
MOhm x kmmin. 10
5
10
5
10
5
10
5
10
5
10
5

Loop resistance
max. (Ohm/km) 110 23 53 171 155 136
Nominal peak voltagekVs 3 5 2 4 1 2
Dielectric strength
50 HzkVeff 7 10 5 7 3 3

Dimensions and specifications may be changed without prior notice. (RM01)

Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility

Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions. The varied
mechanical, thermal and electronic properties of Coaxial cables mean that they can be used up into the GHz levels, as per cable type.

338
Coaxial Cables

RG-Coaxial Cables

Type RG 174 A/U RG 174 U RG 178 B/U RG 179 B/U RG 180 B/U RG 187 A/U
Part no. 40197 400189 40007 40008 40009 40010

Cable structure
Inner conductor diameter mm 7 x 0,2 7 x 0,2 7 x 0,1 7 x 0,1 7 x 0,1 7 x 0,1
Steel/copper, bare Steel/copper, bare Steel/copper, silvered Steel/copper, silvered Steel/copper, silvered Steel/copper, silvered
Insulation mm 1,52 PE 1,52 PE 0,86 PTFE 1,6 PTFE 2,6 PTFE 1,6 PTFE
Outer conductor Braid Braid Braid Braid Braid Braid
Tinned copper Tinned copper Silvered copper Silvered copper Silvered copper Silvered copper
- - - - - -
Outer sheath PVC PVC FEP FEP FEP PFA
Min. bending radius approx. mm 15 15 10 15 25 15
Temperature range C -35 to +80 -35 to +80 -55 to +200 -55 to +200 -55 to +200 -55 to +260
Copper weight kg/km 7,0 7,0 7,0 8,0 11,0 9,0
Outer approx. mm 2,8 2,6 1,8 2,5 3,7 2,6
Weight approx. kg / km 11 11 8 16 28 17

Electrical characteristics
Impedance (Ohm) 50 2 50 2 50 2 75 3 95 5 75 3

M
Frequency range
f (max.) GHz 1 1 3 3 3 3
Propagation velocity v/c 0,7 0,7 0,7 0,7 0,7 0,7
Attenuation at 20C
(db/100m)
100 MHz 30 30 43 28 20 28
200 MHz 45 45 62 41 33 41
500 MHz 73 73 102 69 - 69
800 MHz 93 93 134 92 - 92
1000 MHz - - - - - -
1350 MHz - - - - - -
1750 MHz - - - - - -
CapacitancepF/m 101 101 93 63 50 64
Rel. velocity of propagation % 70 70 70 70 70 70
Insulation resistance
MOhm x kmmin. 10
5
10
5
10
5
10
5
10
5
10
5

Loop resistance
max. (Ohm/km) 360 360 860 840 840 840
Nominal peak voltagekVs 1 1 1 1 2 1
Dielectric strength
50 HzkVeff 2 2 2 2 2 2

Dimensions and specifications may be changed without prior notice.

Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
The colour at FEP and PFA outer sheath is brown or white as per production outlet.
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility

Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions. The varied
mechanical, thermal and electronic properties of Coaxial cables mean that they can be used up into the GHz levels, as per cable type.

339
Coaxial Cables

RG-Coaxial Cables

Type RG 213 RG 214 U RG 217 RG 218 RG 223 U RG 316 B/U


Part no. 40012 40011 40200 40201 40202 40203

Cable structure
Inner conductor diameter mm 7 x 0,8 7 x 0,8 1 x 2,7 1 x 4,95 1 x 0,9 7 x 0,2
Copper, bare Silvered copper Copper, bare Copper, bare Silvered copper Steel/copper, silvered
Insulation mm 7,24 PE 7,24 PE 9,4 PE 17,3 PE 2,95 PE 1,52 PTFE
Outer conductor Braid 2 braids 2 braids Braid 2 braids Braid
Copper, bare 2x silvered copper Copper, bare Copper, bare 2x silvered copper Silvered copper
- - - - - -
Outer sheath PVC PVC PVC PVC PVC PTFE/ alt. FEP
Min. bending radius approx. mm 50 50 70 110 25 15
Temperature range C -35 to +80 -35 to +80 -35 to +80 -35 to +80 -35 to +80 -55 to +200
Copper weight kg/km 85,0 120,0 187,0 348,0 44,0 9,0
Outer approx. mm 10,3 10,8 13,84 22,1 5,2 2,5
Weight approx. kg / km 159 198 300 710 60 15

Electrical characteristics
Impedance (Ohm) 50 2 50 2 50 2 50 2 50 2 50 2
Frequency range
f (max.) GHz 3 11 3 3 3 3
Propagation velocity v/c 0,7 0,7 0,66 0,66 0,7 0,7
Attenuation at 20C
(db/100m)
100 MHz 7 7 4,8 2,9 17 28
200 MHz 10,2 10,2 7,1 4,5 23 40
500 MHz 17 17 12,3 8,1 38 68
800 MHz 23 23 16,8 11,2 50 90
1000 MHz - - - - - -
1350 MHz - - - - - -
1750 MHz - - - - - -
CapacitancepF/m 101 101 101 101 101 95
Rel. velocity of propagation % 100 67 100 100 67 70
Insulation resistance
MOhm x kmmin. 10
5
10
5
10
5
10
5
10
5
10
5

Loop resistance
max. (Ohm/km) 10 10 5 2 36 310
Nominal peak voltagekVs 5 5 7 11 2 1
Dielectric strength
50 HzkVeff 10 10 10 15 5 2

Dimensions and specifications may be changed without prior notice.

Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
The colour outer sheath at PTFE is brown or transparent as per production outlet.
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility

Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions. The varied
mechanical, thermal and electronic properties of Coaxial cables mean that they can be used up into the GHz levels, as per cable type.

340
Coaxial Cables

Halogen-Free RG-Coaxial Cables

Type RG.../U 11 A/U 58 C/U 59 B/U 62 A/U 71 B/U 213 U 214 U


Part no. 40190 40191 40192 40193 40194 40195 40196

Cable structure
Inner conductor diameter mm 7 x 0,4 19 x 0,2 1 x 0,6 1 x 0,6 1 x 0,6 7 x 0,8 7 x 0,8
Tinned copper Tinned copper Steel/copper, bare Steel/copper, bare Steel/copper, bare Copper, bare Silvered copper
Insulation mm 7,3 PE 2,95 PE 3,7 PE 3,7 PE, hollow 3,7 PE, hollow 7,24 PE 7,24 PE
Outer conductor Braid Braid Braid Braid 2 braids Braid 2 braids
Copper, bare Tinned copper Copper, bare Copper, bare Copper, bare Copper, bare 2x silvered copper
- - - - Tinned copper - -
Outer sheath HM2 HM2 HM2 HM2 HM2 HM2 HM2
Min. bending radius approx. mm 50 25 30 30 30 50 50
Temperature range C -35 to +80 -35 to +80 -35 to +80 -35 to +80 -50 to +70 -35 to +80 -35 to +80
Copper weight kg/km 58,0 29,0 28,0 28,0 48,0 85,0 120,0
Outer approx. mm 10,3 5,4 6,4 6,4 6,9 10,3 10,8
Weight approx. kg / km 144 38 57 54 64 155 203

Electrical characteristics
Impedance (Ohm) 75 3 50 2 75 3 93 5 93 3 50 2 50 2

M
Frequency range
f (max.) GHz 3 3 3 3 3 3 11
Propagation velocity v/c 0,7 0,7 0,7 0,8 0,8 0,7 0,7
Attenuation at 20C
(db/100m)
3 MHz 1,3 2,9 2 2 2 1,2 1,2
10 MHz 2,4 5,3 3,8 3,7 3,7 2,3 2,3
100 MHz 7,8 17 12,2 12 12,5 7,5 7,5
200 MHz 11,3 24,4 17,6 17,3 17,3 10,9 10,9
500 MHz 18,7 39,2 27,2 24,7 24,7 17,2 17,2
800 MHz 23,4 47,8 35,2 34,6 34,6 22,6 22,6
CapacitancepF/m 68 0 68 42,5 42,5 101 101
Rel. velocity of propagation % 67 67 67 43 43 101 101
Insulation resistance
MOhm x kmmin. 10
5
10
5
10
5
10
5
10
5
10
5
10
5

Loop resistance
max. (Ohm/km) 23 53 171 155 136 10 10
Nominal peak voltagekVs 5 2 2 1 1 5 5
Dielectric strength
50 HzkVeff. 10 5 7 3 3 10 10

Dimensions and specifications may be changed without prior notice. (RM01)

Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
H-outer sheath = halogen-free material (HM2)
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility
FRNC = Flame Retardant Non-Corrosive

Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions where no
flame propagation under behaviour in fire is permitted. The varied mechanical, thermal and electronic properties of Coaxial cables mean that they can
be used up into the GHz levels, as per cable type.

341
Coaxial Cables

CATV-Cables with alu- or copper foil and braiding

used as Underground Outdoor span Underground BK-Underground BK-Underground BK-Underground BK-Underground


Type 0.7/4.4 1.1/7.3 1.1/7.3 1.8/11.5 A-2YK2Y1 A-2Y0K2Y1 A-2Y0K2Y1 A-2Y0K2Y1
ALG ALG ALG-T FG iKx 1.1/7.3 nKx 2.2/8.8 qKx 3.3/13.5 sKx 4.9/19.4
Part no. 40135 40139 40140 40141 40142 40143 40144 40179

Cable structure
Inner conductor diameter mm 0,7 1,1 1,1 1,8 1,1 2,2 3,3 4,9
Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare
Insulation mm 4,4 PE 7,3 PE 7,3 PE 11,5 PE 7,3 PE 8,8 PE, hollow 13,5 PE, hollow 19,4 PE, hollow
Outer conductor Polyester foil Polyester foil Polyester foil Copper tape Copper tube, Copper tube, Copper tube, Copper tube,
coated with coated with coated with welded welded welded welded
aluminium on both aluminium on both aluminium on both
sides sides sides
Braid Braid Braid Braid - - - -
- - - - - - - -
Outer sheath PVC PE PE PE PE PE PE PE
Sheath colour white black black black black black black black
Outer approx. mm 6,6 10,5 2,8 15,0 11,0 12,5 17,0 24,4
Min. bending radius approx. mm 35 100 150 150 160 200 300 400
Strain/suspending wire N - - 5500 - - - - -
Weight approx. kg / km 44 98 177 218 142 183 347 500

Electrical characteristics
Impedance (Ohm) 75 3 75 3 75 3 75 3 75 2 75 2 75 1 75 1
CapacitancepF/m 67 67 67 67 65 51 51 50
Propagation velocity v/c 0,7 0,7 0,7 0,7 0,7 0,88 0,88 0,89
Attenuation at 20C
(db/100m)
100 MHz 9 5,2 5,2 3,5 5,4 2,8 1,9 1,3
200 MHz 12 7,3 7,3 5,2 7,9 4 2,7 1,9
500 MHz 21,2 12,6 12,6 9 12,9 6,6 4,4 3,1
800 MHz 27,5 16,8 16,8 12 17,3 8,4 5,7 4,1
950 MHz 30,5 18,8 18,8 13 18,9 9,3 6,3 4,4
1350 MHz 37 23 23 - - - - -
1750 MHz 43 27,7 27,7 - - - - -
2050 MHz 47,5 30,2 30,2 - - - - -
Structural return loss min. (dB) between
30 and 300 MHz 30 32 32 30 26 26 28 28
300 and 600 MHz 30 32 32 30 23 23 25 25
600 and 960 MHz 25 30 30 28 21 21 23 23
960 and 1750 MHz 23 27 27 25 - - - -

DC resistance at 20C
Inner conductor max.Ohm/km 47 18,5 18,5 7,3 22 5,6 2,5 1
Outer conductor max.Ohm/km 23 11 11 6,5 3,1 3 2 1

Screening efficiency (dB)


50 and 100 MHz 75 80 80 80 110 110 110 110
100 and 500 MHz 75 85 85 85 110 110 110 110
500 and 1000 MHz 75 85 85 85 110 110 110 110
1000 and 2050 MHz 75 78 78 80 110 110 110 110

Post office approved G670009A G670011A G622015B G622010B - - - -

Dimensions and specifications may be changed without prior notice. (RM01)

Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
BK-underground: broadband cable in accordance with FTZ 15 TV 11 (post cable)
AL=Aluminium, ALPR=Polyesterfoil coated with Aluminium on both sides
BK-cable=broadband communication cable, Cu=Copper, CuR=Cu-tube welded, CuW=Copperweld, F=Foil, G=Braid, PE=Polyethylene,
PEH=Polyethylene air-space insulation, PVC=Polyvinylchloride

342
Coaxial Cables

SAT-Coaxial Cables up to 2150 MHz, for satellite-receivers, double screened

Type 1,1/4,8 1.65/7.2 ALG SAT-MINI 1 DUO 2x0.7/2.9 QUADRO 4x0.7/2.9


Part no. 40150 40151 40159 40168 40169

Cable structure
Inner conductor diameter mm 1,1 Tinned copper 1,6 Copper, bare 0,8 Copper, bare 0,65 Copper, bare 0,6 Copper, bare
Insulation mm 5 Cell PE 7,2 Cell PE 3,5 Cell PE 3 Cell PE 3 Cell PE
Core colours - - - - -
Outer conductor Polyester foil coated with Polyester foil coated with Polyester foil coated with Polyester foil coated with Polyester foil coated with
aluminium on both sides aluminium on both sides aluminium on both sides aluminium on both sides aluminium on both sides
Braid Braid Braid Braid Braid
- - - - -
Outer sheath PVC PE PVC PVC PVC
Sheath colour white black white white white
Outer approx. mm 6,8 10,1 5,4 x 10,8 8,6 x 4,3 20,0 x 4,3
Min. bending radius approx. mm 50 60 40 35 80
Weight approx. kg / km 49 81 62 40 82

Electrical characteristics
Impedance (Ohm) 75 3 75 3 75 3 75 3 75 3

M
CapacitancepF/m 55 55 55 55 55
Propagation velocity v/c 0,8 0,82 0,82 0,8 0,8
Attenuation at 20C
(db/100m)
100 MHz 5 3,7 8 8,9 8,9
200 MHz 7,3 5,1 11,5 13,5 13,5
500 MHz 13 9 18,5 22 22
800 MHz 17,2 11,8 23,5 28 28
950 MHz 19,5 13,6 25,5 31,5 31,5
1350 MHz 23,5 16,8 31 37 37
1750 MHz 27,6 19,7 35,5 42,3 42,3
2050 MHz 30 22 39,5 45,9 45,9
2150 MHz 31 22,5 43 50,4 50,4
Structural return loss min. (dB) between
30 and 300 MHz 28 31 27 20 20
300 and 600 MHz 28 30 25 17 18
600 and 960 MHz 26 30 20 17 15
960 and 2050 MHz 24 28 20 - -

DC resistance at 20C
Inner conductor max.Ohm/km 18 9 36 110 52
Outer conductor max.Ohm/km 20 12 28 22 26
Max. nominal voltage (V) - - - - -

Screening efficiency (dB)


50 and 100 MHz 75 80 78 75 75
100 and 500 MHz 75 85 78 75 75
500 and 1000 MHz 75 85 75 75 75
1000 and 2050 MHz 75 78 75 75 75

Post office approved G670010A G622016B - - -


Copper weight kg/km 21,0 35,0 30,0 16,0 50,0

Dimensions and specifications may be changed without prior notice. (RM01)

Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
AL=Aluminium, ALPR=Polyesterfoil coated with Aluminium on both sides
Cu=Copper, CuW=Copperweld, F=Foil, G=Braid, PE=Polyethylene, PEH=Polyethylene air-space insulation, PVC=Polyvinylchloride, vz=tinned

343
Coaxial Cables

Multimedia-Coaxial Cables SAT 1,0/4,6GH, up to 2400MHz, for digital-tv,


double screened, screening efficieny >90dB

used as inner/outer Underground Safety zones


Type 1.0/4.6 GH-Y 1.0/4.6 GH-2Y 1.0/4.6 GH-FRNC
Part no. 40176 40177 40178

Cable structure
Inner conductor diameter mm 1 Copper with skin 1 Copper with skin 1 Copper with skin
Insulation mm 4,6 Cell polyethylene with skin and PIB 4,6 Cell polyethylene with skin and PIB 4,6 Cell polyethylene with skin and
coating coating PIB coating
Outer conductor Polyester foil coated with aluminium on Polyester foil coated with aluminium on Polyester foil coated with aluminium
both sides both sides on both sides
Outer sheath PVC PE FRNC
Sheath colour white black grey
Outer approx. mm 6,6 6,6 6,6
Approv. bending radius approx. mm 45 45 45
Weight approx. kg / km 40 40 40

Electrical characteristics
Impedance (Ohm) 75 1 75 1 75 1
CapacitancepF/m 55 55 55
Propagation velocity v/c 0,8 0,85 0,85
Attenuation at 20C
(db/100m)
100 MHz 5,8 5,8 5,8
200 MHz 7,8 7,8 7,8
450 MHz 12,5 12,5 12,5
600 MHz 14,7 14,7 14,7
800 MHz 17,2 17,2 17,2
1000 MHz 19,1 19,1 19,1
1750 MHz 26,2 26,2 26,2
2050 MHz 28,5 28,5 28,5
2400 MHz 31,3 31,3 31,3
Structural return loss min. (dB) between
30 and 300 MHz 30 30 30
300 and 600 MHz 32 32 32
600 and 960 MHz 31 31 31
960 and 1750 MHz 26 26 26
1750 and 2400 MHz 30 30 30

DC resistance at 20C
Inner conductor max.Ohm/km 18 18 18
Outer conductor max.Ohm/km 20 20 20
Max. nominal voltage (V) - - -

Screening efficiency (dB) 90 90 90


Copper weight kg/km 22,0 22,0 22,0

Dimensions and specifications may be changed without prior notice. (RM01)

Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
FRNC=Flame Retardant Non Corrosive, PEE= Cell-Polyethylene, PIB= Polyisobutylene, ALPR=Polyesterfoil coated with Aluminium on both sides
F=Foil, G=Braid, GH=Braid-covering ca. 88%

Application
Copper inner-conductor 1,02 with skin-effect
Protection against humidity and corrosion / Solid compound of dielectric. No change of position during installation in narrow bending radius.
Dielectric 4,6 mm : - special PE-compound, foaming by GAS-INJEKTION
Important improvement of propagation velocity values / Very high transmission speed of individual signals (presumption for Multimedia) /
Improvement for the resistance to ageing / Reduction of attenuation-loss by approx. 2dB
The over surface of dielectric consists too a skin-coating (smooth over surface)
Protection against humidity and other chemical influences / Minimum impedance tolerance 2 Ohm / This coaxial cable is crimpable / Installation
in narrow bending radius, no kinking risk / The transmission-loss of signals are hardly measurable to the advance in years / Additionally to the
skin-effect, the dielectric contains a gel-coating (special PIB-cpmpound) / We therefore offer a 15 years guarantee for attenuation-loss by
installation at 20C room-temperature
Screening
a) AL/PR-foil, polyesterfoil coated with aluminium on both sides or b) Copper braiding of tinned wires, screening efficiency >90 dB

344
Coaxial Cables

SAT-Coaxial Cables for digital-tv, screening efficieny >90dB / >95dB, for


satellite-receivers, double screened

used as inner inner/outer inner/outer inner Underground inner inner/outer inner


Type 0,7/2,9 0,7/4,5 0,8/3,5 1,1/5,0 1.6/7,0 1,1/5,0 1,1/5,0 1.6/7.0
FRNC FRNC FRNC
Part no. 40015 40016 40085 40017 40018 40019 40021 40020

Cable structure
Inner conductor diameter mm 0,6 0,75 0,8 1,1 1,63 1,1 1,1 1,6
Copper, bare Tinned copper Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare
Insulation mm 3 Polyethylene, 4,5 Polyethylene, 3,5 Polyethylene, 4,8 Polyethylene, 7,1 Polyethylene, 4,8 Cell PE, 4,8 Cell PE, 7,1 Polyethylene,
foamed foamed foamed foamed foamed foamed foamed foamed
Outer conductor ALPR-FG ALPR-FG ALPR-FG ALPR-FG ALPR-FG ALPR-FG ALPR-FG ALPR-FG
- - - - - - - -
1st Screen - ALPR foil foil foil foil foil foil foil foil
2nd Screen - Cu-Braid Braid Braid Braid Braid Braid Braid Braid Braid
Outer sheath PVC PVC PVC PVC PE FRNC FRNC FRNC
Sheath colour white white white white black white black white
Outer approx. mm 4,3 6,6 5,0 6,9 10,3 6,8 6,8 10,0

M
Min. bending radius approx. mm 43 35 50 45 60 48 48 60
Weight approx. kg / km 20 40 32 47 110 47 47 110

Electrical characteristics
Impedance (Ohm) 75 3 75 3 75 3 75 2 75 2 75 2 75 2 75 2
CapacitancepF/m 55 67 53 55 55 53 55 53
Propagation velocity v/c 0,8 0,66 0,8 0,8 0,85 0,8 0,8 0,8
Attenuation at 20C
(db/100m)
100 MHz 8,1 7,1 6,3 4,9 3 4,7 4,9 3,8
200 MHz 13,3 10,4 11,5 7,7 6,1 7 7,2 5,5
450 MHz 20,9 16,8 17,1 11,6 9 11,5 11,6 8,6
800 MHz - 25 - - - 17 - 12,1
1000 MHz 31,5 27,4 26,5 18,9 14,3 18,1 18,9 13,2
1750 MHz 42,2 37,4 36,4 26,6 20,1 25 26,6 17,5
2050 MHz 45,8 40,5 39,7 28,2 22,5 27,3 28,2 19
2250 MHz 49,9 44,3 43,1 29,5 24 28 29,5 19,9
2400 MHz 55,5 45 - 31,9 - 29,3 31,9 22,5
Structural return loss min. (dB) between
30 and 300 MHz 20 20 35 25 40 25 40 25
300 and 600 MHz 18 18 35 18 35 18 40 18
600 and 960 MHz 16 18 30 17 35 17 35 17
960 and 1750 MHz - - 30 15 30 15 30 15

DC resistance at 20C
Inner conductor max.Ohm/km 52 110 36 18 9 18 18 9
Outer conductor max.Ohm/km 29 22 28 14 21 14 14 21
Max. nominal voltage (V) - - - - - - - -

Screening efficiency (dB)


50 and 100 MHz 95 90 90 95 90 90 95 90
100 and 500 MHz 95 90 90 95 90 90 95 90
500 and 1000 MHz 95 90 90 95 90 90 95 90
1000 and 2050 MHz 95 90 90 95 90 90 95 90

Copper weight kg/km 12,5 9,0 9,0 25,0 32,0 25,0 25,0 50,5

Dimensions and specifications may be changed without prior notice. (RM01)

345
Coaxial Cables

RGB-COAX-CY / RGB-COAX-(St)Y transmission cables for colour


monitor

Technical data Cable structure Properties


Base cable 0,37/1,5 or 0,6/3,7 RGB-COAX-CY ... x0,37/1,5 The materials used in manufacture are
Temperature range Inner conductor bare copper, solid, cadmium-free and contain no silicone
fixed installation -10C to +80C conductor 0,37 mm and free from substances harmful to
flexing -5C to +50C Dielectric (insulation) of cell-Polyethylene the wetting properties of lacquers.
Mutual capacitance 67 nF/km Outer conductor of tinned copper wire
Impedance 75 Ohm braiding
Attenuation PVC-sheath in colour
RGB-Coax 0,37/1,5 red, green, blue for 3xRGB COAX
1 MHz = 2,0 dB/100m red, green, blue, white, black for
2 MHz = 2,8 dB/100m 5xRGB COAX
5 MHz = 4,0 dB/100m 3 or 5 Coax twisted with optimal lay-length
10 MHz = 5,8 dB/100m Foil taping
20 MHz = 8,4 dB/100m Overall braid-screening, tinned copper with
50 MHz = 13,9 dB/100m optimal surface coverage and drain-wire
100 MHz = 19,8 dB/100m PVC-outer sheath, black
200 MHz = 28,5 dB/100m RGB-COAX-CY 3x0,37/1,5 + 3x0,25
RGB-Coax 0,6/3,7 Cable structure as per above, but with
1 MHz = 1,1 dB/100m 3 additional control cores (3x0,25) in the
2 MHz = 1,5 dB/100m interstices, colour brown, green, white
5 MHz = 2,5 dB/100m RGB-COAX-(St)Y ... x0,6/3,7 (deviation)
10 MHz = 3,5 dB/100m Inner conductor, bare copper, solid,
20 MHz = 4,5 dB/100m conductor 0,6 mm
50 MHz = 7,2 dB/100m Outer conductor of tinned or bare copper
100 MHz = 10,4 dB/100m wire braiding
200 MHz = 15,1 dB/100m Foil taping
Minimum bending radius Plastic coated aluminium foil and drain wire
15x cable Outer sheath of PVC, green or black

Application
RGB cables are suitable for the transmission of both analogue and digital video signals.
They are used particularly as connecting cables for data systems, engineering applications (CAD, high-definition graphics) and in television studios.
The three main signals (red, green, blue) are transmitted separately. Depending on the application, it is possible to supply the base cable with further
coaxial cables or with symmetrical signal cores for the intensity and horizontal or vertical synchronisation.
RGB-COAX-CY ... 0,37/1,5 RGB-COAX-(St)Y ... 0,6/3,7
Part no. No. RGB-Coax Outer Cop. Weight Part no. No. RGB-Coax Outer Cop. Weight
n x mm approx. weight approx. n x mm approx. weight approx.
mm kg / km kg / km mm kg / km kg / km
40145 3 x 0,37/1,5 7,2 23,0 59,0 40148 3 x 0,6/3,7 16,0 66,0 278,0
40147 3 x 0,37/1,5 + 3 x 0,25 8,2 60,5 89,0 40149 5 x 0,6/3,7 19,0 102,0 397,0
40146 5 x 0,37/1,5 9,0 36,0 89,0

Dimensions and specifications may be changed without prior notice. (RM01)

346
NFPA 79 EDITION 2012
Challenges and solutions
THE COMPLETE ORIGINAL WORDING

12.9 Special Cables and Conductors


In 1897 the first edition of the National Electrical Code (NEC), 12.9.1 Other listed cables and conductors shall be permitted
also referred to as NFPA 70, was published. The NEC is the only where identified as suitable for the identified use
12.9.2 Appliance Wiring Material (AWM) shall be permitted
code for electrical installations that is recognized at the national
under 12.9.2.1 through 12.9.2.3
level in the USA. It deals with fire triggered by electricity. It is 12.9.2.1 Where part of an assembly that has been identified
updated every three years, i.e. the 2012 edition appeared in for intended use
12.9.2.2 Where specified for use with approved equipment
2011. In article 670 "Industrial Machinery", the NEC refers to and used in accordance with the equipment manu-
NFPA code no. 79 (Electrical Standard for Industrial Machinery). facturers instructions.
12.9.2.3 Where its construction meets all applicable requirements
This standard cites basic requirements imposed on the electrical
of sections 12.2 12.6 with modifications as folIows:
equipment of machines and devices. Manufacturers and owners (1) Stranded conductors with wire sizes smaller than
of machines and equipment must comply with this standard, for those listed in 12.2.2 shall have a minimum of 7 strands.
(2) Conductor insulation and cable jacket materials
example, to meet product liability and insurance requirements. not specified in 12.3.1 have flame resistant properties
in compliance with applicable standards for intended
use such as FT2 (horizontal wire) flame test or VW-1
Machines placed in service in the USA are always subject to an
(Vertical Wire) flame test in ANSI/UL 1581-2001,
approval obligation. This can occur either through the individual Reference Standard for Electrical Wires, Cables and
acceptance of a piece of equipment prior to commissioning Flexible Cords.
(3) Minimum insulation thickness for single conductor
(e.g. in Germany) or through a test institute recognized in the AWM shall be as specified in 12.3.2. Minimum insu-
USA. The final decision concerning commissioning is made on lation thickness for conductors that are part of a multi
conductor jacketed AWM cable shall be as specified
site through a local inspector, who may not necessarily be a
by the AWM Style number and by the marked voltage
specialist in the area of electronic equipment. The inspector can rating of the cable.
mandate the provisional stoppage of the machine if there are (4) AWM shall be marked in accordance with 12.4.1,
12.4.3 and 12.4.4. The legend shall include manu-
doubts relative to the machine's conformity with US standards. facturers name or trademark, AWM style number,
voltage rating (unless marking is prohibited by 12.4.2),
wire gauge(s), temperature rating and flame resistance.
NFPA 79: 2007 in chapter 12.2.7.3 "When part of a listed
Additional markings for properties such as oil, water,
assembly suitable for the intended application, type AWM shall UV and chemical resistance identifiers shall be permitted
where in compliance with applicable standards for
be permissible. Allows AWM cables, if they have been used as
part of a listed system, and were suitable for the intended appli-
intended use. Where markings alone are insufficient N
to identify for the intended application, suitable infor-
cation. mation shall be included with the technical machine
documentation.

However there are applications for which previously there were


no NFPA 79 cables. For example, cables for use in energy drag
chains or those with superstructures. There were objections and New certified machines and equipment may continue to be
protests from the industry in this regard. The NFPA reacted built in accordance with the previous rules. The certification
accordingly and called in a committee of experts. As a result, will be recognized.
in NFPA 79: Edition 2012, use of AWM cables under certain For new machines and equipment without certification, in
conditions was again approved. As before, unrestricted use is some areas higher requirements imposed on certain cables
not permitted. Rather the responsibility for the implementation is (e.g. UL Listing) could apply. In this case the important thing is
now placed on the manufacturer or the erector of the to consult with the respective certification authority.
equipment. Article 12.2.7. of edition 2007 was completely
eliminated. All recommendations have been summarized in the In many cases, HELUKABEL recommends the use of UL-listed
new article 12.9. lines, as before. Our technical dept. would be pleased to provide
additional information at tel. +49 7150 92 09 -0.
SUMMARY
Machines and equipment that is already certified (e.g. through
UL) may continue to be repaired, modified, or extended in
accordance with the previous rules.

349
CABLES ACCORDING TO INTERNATIONAL APPROVALS

3
in

E
VD iel 029
ng

x
xe
ex

VD
g e 0 /U

ed
xi
- fi
- fl

./
le

fix

E
lta U

ed

no
H A ed / VD
-f
C)

C)

vo e

s-

d
al ag

us

CS REG
(

s
re ree
in volt

R/ /sh
di

di

re core
se
re

re

t
ut tan

n
ra

a
tu

tu

Dr or u
f

E
r

Co hai
n-
om l

Pa 9
is
ra

ra

g
N ina

A
d

7
ge

s
in

in

en
pe

pe

re
c
do

A
ge
om

nd

nd

ag
lo

lo
V-
m

L/

FP
Ha
Be

Be

Sc
Te

Te

O
U

N
PVC control lines UL/CSA

JZ-602 -5 to +90 -40 to +90 600 7.5x 4x X 356

JZ-603 -5 to +90 -40 to +90 600 7.5x 4x X X 358

TRAYCONTROL 500
-5 to +90 -40 to +90 600 4x 4x X X 359

TRAYCONTROL 530 -5 to +90 -40 to +90 600 5x 5x X X 361

JZ-600 UL/CSA -5 to +80 -40 to +80 1000 7.5x 4x X X X 362

JZ 604 TC TRAY CABLE -5 to +75 -25 to +75 600 7.5x 7.5x X X X X 364

TRAYCONTROL 600 -40 to +90 600 5x 5x X X X X 366

H05VV-F/SJT -5 to +60 -40 to +60 300 7.5x 7.5x X X X 368

H05VV-F/SJT -5 to +60 -40 to +60 300 7.5x 7.5x X X X 369

H05VV-F/UL -5 to +75 -40 to +75 300/500 7.5x 7.5x X X X 370

FROR CEI 20-22 II -5 to +70 -35 to +70 300/500 10x 10x (X) 371

C.N.O.M.O -5 to +80 -30 to +80 500 15x 15x 372

JZ-602-CY -5 to +90 -40 to +90 600 10x 5x X X 373

JZ-603-CY -5 to +90 -40 to +90 600 10x 5x X X X 375

TRAYCONTROL 500-C -5 to +90 -40 to +90 600 6x 6x X X X 376

JZ-600-Y-CY UL/CSA -5 to +80 -40 to +80 1000 10x 5x X X X X 378

JZ 604-FCY TC TRAY CABLE -5 to +75 -25 to +75 600 10x 10x X X X X X 380

JZ 604-YCY TC TRAY CABLE -5 to +75 -25 to +75 600 10x 10x X X X X X 381

TRAYCONTROL 600-C -40 to +90 600 6x 6x X X X X X 382

PUR/TPE control lines UL/CSA

JZ-602-PUR -5 to +80 -40 to +80 600 7.5x 4x X X X 384

JZ-602-PUR DC/AC -5 to +80 -40 to +80 600 7.5x 4x X X X 386

JZ-600 PUR -5 to +80 -40 to +80 1000 7.5x 4x X X X 387

JZ-602-C-PUR -5 to +80 -40 to +80 600 10x 5x X X X X 389

JZ-600-YC-PUR -5 to +80 -40 to +80 1000 10x 5x X X X X 390


TRAYCONTROL
-40 to +105 600 7.5x 7.5x X /X X X 392
670 HDP / 670-C HDP
Halogen-free control lines UL/CSA

MEGAFLEX 500 -30 to +80 -40 to +80 600 10x 4x X X X X 394

MEGAFLEX 600
-30 to +80 -40 to +80 600 10x 4x X X X X 396

MEGAFLEX 500-C

-30 to +80 -40 to +80 600 10x 4x X X X X X 398

MEGAFLEX 600-C -30 to +80 -40 to +80 600 10x 4x X X X X X 400

Data lines UL/CSA

Command Cable UL (LiYY) -10 to +80 -20 to +80 300 15x 7.5x X X 403

Command Cable UL (LiYY) -10 to +105 -20 to +105 600 15x 7.5x X X 404

TRAYCONTROL 300 -25 to +105 300 6x 6x X X X 405

Command Cable UL (LiYY-TP)) -10 to +80 -20 to +80 300 15x 7.5x X X 407

TRAYCONTROL 300 TP -25 to +105 300 6x 6x X X X 409

VERTEILERFLEX two-approvals -5 to +80 -30 to + 80 300/500 15x/7.5x 15x/7.5x (X) X X 411

Command Cable UL (LiYCY) -10 to +80 -20 to +80 300 15x 7.5x X X X 413

Command Cable UL (LiYCY) -10 to +105 -20 to +105 600 15x 7.5x X X X 415

TRAYCONTROL 300-C

-25 to +105 300 6x 6x X X X X 416

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

350
CABLES ACCORDING TO INTERNATIONAL APPROVALS

3
in

E
VD ield 029
ng

x
xe
ex

VD
g e 0 /U

d
xi
- fi
- fl

./
le

fix

E
lta U

d
no
H A d / VD
-f

e
C)

C)

vo e

-
al ag

us

us

CS REG
(

en res
e
in volt

R/ /sh
di

di

ag use
re

re

t
e
an
V- -fr

lo in
ra

ra

o
tu

tu

E
Sc d c
O sist

a
om l

Pa 79
r
ra

ra

n
g

g
N ina

A
e
ch
o
ge
in

in
pe

pe

re
do
re

A
ge
om

nd

nd

lo

re
m

L/

FP
ut
Ha

Co
Be

Be

Dr
Te

Te

N
Data lines UL/CSA

Command Cable UL (LiYCY-TP) -10 to +80 -20 to +80 300 15x 7.5x X X X 418

TRAYCONTROL 300-C TP
-25 to +105 300 6x 6x X X X X 420

Drag chain cables UL/CSA

JZ-602 RC -5 to +90 -40 to +90 600 7.5x 4x X X X X 423

MULTIFLEX 600 -5 to +90 -40 to +90 600 7.5x 7.5x X X X X X 424

MULTISPEED 500-PVC UL/CSA -5 to +80 -30 to +80 600 7.5x 4x X X X X 425

JZ-HF-FCY -5 to +80 -40 to +80 1000 10x 5x X X X 426

JZ-602 RC -CY -5 to +90 -40 to +90 600 10x 5x X X X X X 427

MULTIFLEX 600-C -5 to +90 -40 to +90 600 10x 10x X X X X X X 428

MULTISPEED 500-C-PVC UL/CSA -5 to +80 -30 to +80 600 7.5x 4x X X X X X 429

JZ-602 RC -PUR -5 to +80 -40 to +80 600 7.5x 4x X X X X 430

MULTIFLEX 512 PUR UL/CSA -30 to +80 -40 to +80 600 5x 3x X X X X X 431

MULTISPEED 500-PUR UL/CSA -30 to +80 -40 to +80 600 7.5x 4x X X X X X 433

PUR-JZ-HF-FCP -5 to +80 -40 to +80 1000 10x 5x X X X X X 435

JZ-602 RC -C-PUR -5 to +80 -40 to +80 600 10x 5x X X X X X 436

MULTIFLEX 512 C-PUR UL/CSA



-30 to +80 -40 to +80 600 7.5x 4x X X X X X X 437

MULTISPEED 500-C-PUR UL/CSA -30 to +80 -40 to +80 600 7.5x 4x X X X X X X 539

MULTISPEED 500-TPE UL/CSA



-30 to +80 -40 to +80 600 5x 3x X X X X X 441

MULTISPEED 500-C-TPE UL/CSA -30 to +80 -40 to +80 600 5x 3x X X X X X X 443

SUPERTRONIC -310-PVC
-5 to +80 -40 to +80 300 5x 3x X X 445

N
SUPERTRONIC-310-C-PVC -5 to +80 -40 to +80 300 7.5x 4x X X X 446

SUPERTRONIC -330 PUR



-30 to +80 -40 to +80 300 5x 3x X X X X X X 447

MULTISPEED TRONIC-PUR -30 to +80 -40 to +80 300 7.5x 4x X X X X X X 448

SUPERTRONIC 330 C-PUR



-30 to +80 -40 to +80 300 7.5x 4x X X X X X X X 449

MULTISPEED TRONIC-C-PUR -30 to +80 -40 to +80 300 7.5x 4x X X X X X X X 450

SUPER-PAAR-TRONIC 340-C-PUR -30 to +80 -40 to +80 300 10x 5x X X X X X X X 451

Motor, servo, feedback cables UL/CSA

TOPFLEX - EMV-UV-2YSLCYK-J -5 to +80 -40 to +80 1000 20x 10x X X X X X 453


TOPFLEX - EMV-UV-3 PLUS
-5 to +80 -40 to +80 1000 20x 10x X X X X X 455
2YSLCYK-J
TOPFLEX MOTOR-EMV 103 -5 to +70 -40 to +80 1000 20x 10x X X X 457

TOPFLEX 600 VFD


-25 to +90 600 6x 6x X X X X X 458

TOPFLEX 650 VFD


-25 to +105 -25 to +105 600 6x 6x X X X X X 459

TOPFLEX 1000 VFD -25 to +90 -25 to +90 600 15x 7.5x X X X X X 460

TOPFLEX EMV UV 2YSLC11Y-J



-5 to +80 -40 to +80 1000 20x 10x X X X X X 461

TOPFLEX MOTOR EMV 1/1 -30 to +80 -40 to +80 1000 20x 10x X X X X X 462

TOPFLEX MOTOR EMV 3/3 -30 to +80 -40 to +80 1000 20x 10x X X X X X 463

TOPSERV PVC 108, 112, 119 -0 to +60 -20 to +80 1000 15x 5x X X 465

TOPGEBER 511 PVC -0 to +60 -20 to +80 30 15x 6x X X X 467

TOPSERV PUR 109, 113, 121 -30 to +80 -40 to +80 1000 7.5x 4x X X X X X 468

TOPGEBER 512 PUR -30 to +80 -40 to +80 30 10x 6x X X X X X X 470

TOPSERV 600 VFD -25 to +90 -25 to +90 600 7.5x 5x X X X X X X 472

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

351
CABLES ACCORDING TO INTERNATIONAL APPROVALS

3
in

E
VD ield 029
ng

x
xe
ex

VD
g e 0 /U

d
xi
- fi
- fl

./
le

ix

E
lta U

ed

no
H A ed / VD
-f

-f
C)

C)

vo e
al ag

us

CS REG
(

s
re ree
in volt

R/ /sh
di

di

re core
se
re

re

t
an

n
ra

ra
tu

tu

Dr or u
f

E
Co hai
n-

O sist
om l

Pa 9
ra

ra

g
N ina

A
d

7
ge
in

in

en
pe

pe

re
c
do

A
ge
om

nd

nd

ag
lo

lo
V-
m

L/

FP
ut
Ha
Be

Be

Sc
Te

Te

N
Motor, servo, feedback cables UL/CSA

TOPSERV 650 VFD -25 to +105 -25 to +105 600 7.5x 5x X X X X X X 473

TOPSERV Hybrid -30 to +80 -40 to +80 1000 7.5x 4x X X /X X X 474

Heat-resistant cables UL/CSA

SiHF UL/CSA -50 to +150 600 7.5x 4x X X X X 476

SiHF-C-Si UL/CSA -50 to +150 600 10x 5x X X X X X 478

All-weather cables & rubber cables UL/CSA

Rubber cable/neoprene hose cable -40 to +90 300 X X X X 480

H07RN-F/SOOW -40 to +90 600 10x 7.5x X X X X X 481

Easy-to-wind cables UL/CSA

TROMM-PUR-H -40 to +80 -50 to +80 1000 6x 6x X X X X 483

Single-core UL/CSA

UL-Style 1007, CSA TR 64 -5 to +80 -30 to +80 300 10x 5x X X 485

UL-Style 1569, CSA TR 64 -5 to +105 -30 to +105 300 10x 5x X X 486

UL-Style 1015 -5 to +105 -30 to +105 600 10x 5x X X 487

THREENORM +5 to +70 -10 to +70 600 6x X X X 488

FIVENORM +5 to +90 -40 to +90 600 6x X X X X 490

THHN/THWN / +90 600 8x 8x X X 493

PVC single-cores -5 to +80 -30 to +80 300/300 6x X 494

HELUTHERM 145
-35 to +105 -55 to +105 300 12.5x 4x X X X X X 495

HELUTHERM 145 -35 to +105 -55 to +105 600 12.5x 4x X X X X X 496

UL-Style 3135 -60 to +200 600 15x 15x X X X 497

Single 600-J/-O -5 to +90 -40 to +90 600 7.5x 4x X X X 498

Single 600-CY -J/-O -5 to +90 -40 to +90 600 7.5x 4x X X X X 499

TOPFLEX 302 / 302-UL -15 to +80 -40 to +80 0.6/1 kV 5x 5x X X /X 500

Single 602-RC -J/O -5 to +90 -40 to +90 600 7.5x 3x X X 501

Single 602-RC-CY -J/O -5 to +90 -40 to +90 600 7.5x 3x X X X 502

TOPFLEX 304 / 304-C -5 to +80 -40 to +80 1000 5x 5x X /X X 503

MULTISPEED 600-PUR -J/-O



-30 to +80 -40 to +80 1000 5x 3x X X X X X 504

MULTISPEED 600-C-PUR -J/-O -30 to +80 -40 to +80 1000 5x 3x X X X X X X 505

TOPFLEX 301 / 301-C -15 to +80 1000 7.5x 7.5x X X X /X X 506

British standard cables

HELUKABEL BS 5308-1 -20 to +65 300/500 6x X X 508

HELUKABEL BS 5308-2 -20 to +65 300/500 6x X X 509

HELUKABEL BS 5467 0 to +90 -15 to +90 0.6/1 kV 8x X X X 510

HELUKABEL BS 6724 0 to +90 -20 to +90 0.6/1 kV 8x X X X 511

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties.

352
SELECTION TABLE - DRAG CHAIN CABLES

ng
in

xi

g
/s 2
ce

fle

in
/
an

ex
ge U
(m
-
es ist

lta 0 /

- fl
us

)
-c t d

vo U
/s
di

io
)

C)
g ge
en

(m
ra

at
or

(
tin lta
er
m

re
in

s
25
e

el

ra vo
ee

le
ov

nd

tu

s
c

yc
)

al
to

sp

ac

pe l

ra
ia
m

O ina
be

ov
r

.c
up

te

er

pe
.

ge
.

ax

ax
ou

pr
ax
ax
m

om
.

at
in

m
=

Ap
M

M
0

Pa
M
M

M
M
(D
(1

Te
N
PVC drag chain cables UL/CSA
SUPERTRONIC-310-PVC 5 5xD 2 10 9 Mio PVC/PVC 300V -5 to +80 UL/CSA 445
SUPERTRONIC -310-C-PVC

5 7.5 x D 2 10 9 Mio PVC/CU/PVC 300V -5 to +80 UL/CSA 446
MULTISPEED 500-PVC UL/CSA 100 7.5 x D 5 50 9 Mio PP/PVC 600V -5 to +80 UL/CSA 425
MULTISPEED 500-C-PVC UL/CSA 100 7.5 x D 5 50 9 Mio PP/CU/PVC 600V -5 to +80 UL/CSA 429
JZ-HF-FCY 10 10 x D 2 10 9 Mio PVC/CU/PVC 1000V -5 to +80 UL/CSA 426
JZ-602 RC 10 7.5 x D 2 10 9 Mio PVC/PVC 600V -5 to +90 UL/CSA 423
JZ-602 RC-CY 10 10 x D 2 10 9 Mio PVC/CU/PVC 600V -5 to +90 UL/CSA 427
MULTIFLEX 600 10 7.5 x D 2 10 9 Mio PVC/PVC 600V -5 to +90 UL/CSA 424
MULTIFLEX 600-C 10 10 x D 2 10 9 Mio PVC/CU/PVC 600V -5 to +90 UL/CSA 428
PUR & TPE drag chain cables UL/CSA
SUPERTRONIC-330 PUR 15 5xD 4 10 11 Mio PP/PUR 300V -30 to +80 UL/CSA 447
SUPERTRONIC-330 C-PUR 15 7.5 x D 4 10 11 Mio PP/CU/PUR 300V -30 to +80 UL/CSA 449
SUPER-PAAR-TRONIC 340-C-PUR 30 10 x D 4 50 11 Mio PP/CU/PUR 300V -30 to +80 UL/CSA 451
JZ-602 RC-PUR 15 7.5 x D 3 10 9 Mio PVC/PUR 600V -5 to +80 UL/CSA 430
JZ 602 RC-C-PUR 15 10 x D 3 10 9 Mio PVC/CU/PUR 600V -5 to +80 UL/CSA 436
PUR-JZ-HF-FCP 15 10 x D 3 10 9 Mio PVC/CU/PUR 1000V -5 to +80 UL/CSA 435
MULTIFLEX 512-PUR UL/CSA 100 5xD 4 10 11 Mio PP/PUR 600V -30 to +80 UL/CSA 431
MULTIFLEX 512-C-PUR UL/CSA 100 7.5 x D 4 10 11 Mio PP/CU/PUR 600V -30 to +80 UL/CSA 437
MULTISPEED -TRONIC-PUR

450 7.5 x D 5 50 11 Mio PP/PUR 300V -30 to +80 UL/CSA 448
MULTISPEED-TRONIC-C-PUR 450 7.5 x D 5 50 11 Mio PP/CU/PUR 300V -30 to +80 UL/CSA 450
MULTISPEED 500-PUR UL/CSA 450 7.5 x D 5 50 11 Mio PP/PUR 600V -30 to +80 UL/CSA 433
MULTISPEED 500-C-PUR UL/CSA

450 7.5 x D 5 50 11 Mio PP/CU/PUR 600V -30 to +80 UL/CSA 439 N
MULTISPEED 500-TPE UL/CSA 450 5xD 5 50 11 Mio PP/TPE 600V -30 to +80 UL/CSA 441
MULTISPEED 500-C-TPE UL/CSA 450 5xD 5 50 11 Mio PP/CU/TPE 600V -30 to +80 UL/CSA 443
Single-cores for drag chain cables UL/CSA
SINGLE 602-RC-J/-O 5 7.5 x D 2 10 9 Mio PVC/PVC 600V -5 to +90 UL/CSA 501
SINGLE 602-RC-CY-J/-O 5 7.5 x D 2 10 9 Mio PVC/CU/PVC 600V -5 to +90 UL/CSA 502
MULTISPEED 600-PUR-J/-O 450 5xD 5 50 11 Mio Poly/PUR 1000V -30 to +80 UL/CSA 504
MULTISPEED 600-C-PUR-J/-O 450 5xD 5 50 11 Mio Poly/CU/TPE 1000V -30 to +80 UL/CSA 505
TOPFLEX 301
5 7.5 x D 2 10 10 Mio PVC/PUR 1000V -15 to +80 UL/CSA 506
TOPFLEX 301 C 5 7.5 x D 2 10 10 Mio PVC/CU/PUR 1000V -15 to +80 UL/CSA 506
TOPFLEX 304 5 5xD 2 10 9 Mio PVC/PVC 1000V -5 to +80 UL/CSA 503
TOPFLEX 304 C 5 5xD 2 10 9 Mio PVC/CU/PVC 1000V -5 to +80 UL/CSA 503

A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties and the selection tables cables in drag chains,
see pages 1030 and 1031.

353
SELECTION TABLE - DRAG CHAIN CABLES

ng
in

xi

g
/s 2
ce

fle

in
/
an

ex
ge U
(m
-
es ist

lta 0 /

- fl
us

)
-c t d

vo U
/s
di

io
)

C)
g ge
en

(m
ra

at
or

(
tin lta
er
m

re
in

s
25
e

el

ra vo
ee

le
ov

nd

tu

s
c

yc
)

al
to

sp

ac

pe l

ra
ia
m

O ina
be

ov
r

.c
up

te

er

pe
.

ge
.

ax

ax
ou

pr
ax
ax
m

om
.

at
in

m
=

Ap
M

M
0

Pa
M
M

M
M
(D
(1

Te
N
Motor cables & servo cables for drag chain cables UL/CSA
TOPSERV 109 PUR 30 7.5 x D 4 10 11 Mio PP/CU/PUR 1000V -30 to +80 UL/CSA 468
TOPSERV 113 PUR

30 7.5 x D 4 10 11 Mio PP/CU/PUR 1000V -30 to +80 UL/CSA 468
TOPSERV 121 PUR 30 7.5 x D 4 10 11 Mio PP/CU/PUR 1000V -30 to +80 UL/CSA 468
TOPSERV 600 VFD 10 7.5 x D 2 10 9 Mio PVC/CU/TPE 600V -25 to +90 UL/CSA 472
TOPSERV 650 VFD

10 7.5 x D 2 10 9 Mio PVC/CU/TPE 600V -25 to +90 UL/CSA 473
Feedback cables for drag chain cables UL/CSA
TOPGEBER 512 PUR 30 10 x D 4 50 11 Mio PP/CU/PUR 30V -30 to +80 UL/CSA 470
TOPSERV HYBRID PVC 5 7.5 x D 0,5 2 5 Mio PP/PVC 1000V -30 to +80 UL/CSA 474
TOPSERV HYBRID PUR 50 7.5 x D 5 30 5 Mio PP/PUR 1000V -30 to +80 UL/CSA 474

A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties and the selection tables cables in drag chains,
see pages 1030 and 1031.

354
UL/CSA CONTROL CABLES
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-602 two approval control cable, 90C, 600 V, oil resistant, meter
marking

Technical data Cable structure Properties


Control cable of special-PVC acc. to UL CSA Bare copper-conductor, to Resistant to mineral oils, synthetic
AWM I/II A/B Style 2587(sheath insulation) DIN VDE 0295 cl.5, fine-wire, oils and coolant
and CSA BS 6360 cl.5, IEC 60228 cl.5 The outer sheath is approved with an
Temperature range Core insulation of PVC improved oil-resistance-test
flexing -5C to +90C compound type TI3 to The materials used in manufacture are
fixed installation -40C to +90C DIN VDE 0207-363-3 / DIN EN 50363-3 cadmium-free and contain no silicone
Nominal voltage and class 43 acc. to UL-Std.1581 and free from substances harmful to
UL/CSA 600 V Core identification black cores with the wetting properties of lacquers
Test voltage 3000 V continuous white numbering Tests
Breakdown voltage min. 6000 V GN-YE conductor, 3 cores and above PVC self-extinguishing and flame retardant
Insulation resistance in the outer layer acc. to DIN VDE 0482-332-1-2,
min 20 MOhm x km Cores stranded in layers with optimal DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius lay-length DIN VDE 0472 part 804
flexing 7,5x cable Outer sheath of special PVC test method B), UL VW-1, CSA FT1
fixed installation 4x cable compound type YM5 to
Radiation resistance DIN VDE 0207 part 5 Note
up to 80x106 cJ/kg (up to 80 Mrad) and class 43 acc. to UL-Std.1581 G = with green-yellow conductor
Sheath colour grey (RAL 7001) x = without green-yellow conductor (OZ)
with meter marking Please note the cleanroom qualification
when ordering.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-602-CY, confer page 373

Application
UL-approved and CSA certified flexible control cable rated at 600 V. Used in machine tools, control systems, connection between control panels and
machines, assembly lines and other industrial equipment. Suitable for installation in dry, moist or wet environment and moderate flexing applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
83090 2 x 0,5 20 5,6 9,6 49,0 83104 9 G 1,5 16 11,5 129,7 244,0
83091 3 G 0,5 20 5,9 14,0 58,0 83075 12 G 1,5 16 12,6 173,0 319,0
83092 4 G 0,5 20 6,4 19,0 69,0 83076 18 G 1,5 16 15,8 260,0 451,0
83093 5 G 0,5 20 6,9 24,0 84,0 83077 25 G 1,5 16 18,3 360,0 625,0
83094 7 G 0,5 20 7,5 34,0 123,0 83078 34 G 1,5 16 21,4 490,0 840,0
83100 8 G 0,5 20 8,3 38,4 140,0 83079 41 G 1,5 16 23,3 590,0 1032,0
83101 9 G 0,5 20 8,9 43,2 177,0 83060 2 x 2,5 14 7,8 48,0 115,0
83095 12 G 0,5 20 9,8 58,0 192,0 83061 3 G 2,5 14 8,5 72,0 143,0
83096 18 G 0,5 20 12,0 86,0 256,0 83062 4 G 2,5 14 9,3 96,0 185,0
83097 25 G 0,5 20 14,3 120,0 358,0 83063 5 G 2,5 14 10,4 120,0 221,0
83098 34 G 0,5 20 16,5 163,0 487,0 83064 7 G 2,5 14 11,5 168,0 293,0
83099 41 G 0,5 20 17,9 197,0 580,0 83065 9 G 2,5 14 13,9 216,0 429,0
83080 2x1 18 6,3 19,2 53,0 83066 12 G 2,5 14 15,2 288,0 563,0
83081 3G1 18 6,6 27,0 61,0 83067 18 G 2,5 14 18,7 432,0 854,0
83082 4G1 18 7,2 38,4 74,0 83068 19 G 2,5 14 18,7 456,0 914,0
83565 3x1 18 6,6 27,0 61,0 83069 25 G 2,5 14 22,2 600,0 1188,0
83083 5G1 18 7,9 48,0 90,0 83051 3G4 12 9,7 115,0 232,0
83084 7G1 18 8,7 67,0 130,0 83052 4G4 12 10,6 154,0 298,0
83102 8G1 18 9,5 76,8 144,0 83053 5G4 12 11,8 192,0 358,0
83103 9G1 18 10,4 86,4 180,0 83054 7G4 12 13,1 269,0 460,0
83085 12 G 1 18 11,2 115,2 198,0 83041 3G6 10 11,3 173,0 360,0
83086 18 G 1 18 14,1 173,0 274,0 83042 4G6 10 12,5 231,0 402,0
83087 25 G 1 18 16,8 240,0 384,0 83043 5G6 10 13,9 288,0 484,0
83088 34 G 1 18 19,5 326,0 494,0 83044 7G6 10 15,4 403,0 630,0
83089 41 G 1 18 21,2 394,0 508,0 83031 3 G 10 8 14,7 288,0 535,0
83070 2 x 1,5 16 6,8 28,8 73,0 83032 4 G 10 8 16,3 384,0 653,0
83071 3 G 1,5 16 7,2 44,0 94,0 83033 5 G 10 8 18,3 480,0 786,0
83072 4 G 1,5 16 7,9 58,0 117,0 83034 7 G 10 8 20,2 672,0 1100,0
83073 5 G 1,5 16 8,7 72,0 140,0
83074 7 G 1,5 16 9,7 101,0 186,0

Continuation

356
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-602 two approval control cable, 90C, 600 V, oil resistant, meter
marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
83020 2 x 16 6 18,8 307,0 640,0 83007 3 G 70 2/0 36,8 2016,0 3307,0
83021 3 G 16 6 20,2 461,0 810,0 83008 4 G 70 2/0 40,9 2688,0 4254,0
83022 4 G 16 6 22,3 615,0 1045,0 83009 5 G 70 2/0 45,6 3360,0 5661,0
83023 5 G 16 6 24,9 768,0 1260,0 83010 3 G 95 3/0 40,9 2736,0 4867,0
83024 7 G 16 6 27,5 1075,0 1760,0 83015 4 G 95 3/0 45,6 3648,0 5762,0
83011 3 G 25 4 24,0 720,0 1180,0 83016 5 G 95 3/0 50,7 4560,0 7208,0
83012 4 G 25 4 26,9 960,0 1507,0 83017 3 G 120 4/0 48,1 3456,0 5580,0
83013 5 G 25 4 31,9 1200,0 1858,0 83018 4 G 120 4/0 53,3 4608,0 7280,0
83014 7 G 25 4 33,0 1680,0 2830,0 83019 5 G 120 4/0 58,9 5760,0 8692,0
83001 3 G 35 2 26,2 1008,0 1590,0
83002 4 G 35 2 29,7 1344,0 2123,0
83003 5 G 35 2 33,0 1680,0 2612,0
83004 3 G 50 1 31,9 1440,0 2652,0
83005 4 G 50 1 35,6 1920,0 3058,0
83006 5 G 50 1 39,7 2400,0 4093,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

357
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-603 Multi approval control cable, oil resistant, meter marking

Technical data Cable structure Properties


Special PVC control cable with Bare copper-conductor, to The materials used in manufacture are
oil resistant outer sheath to DIN VDE 0295 cl.5, fine-wire, cadmium-free and contain no silicone
DIN VDE 0285-525-2-51/ BS 6360 cl.5, IEC 60228 cl.5 and free from substances harmful to
DIN EN 50525-2-51 and UL-Style 2587 Core insulation of special PVC the wetting properties of lacquers
Temperature range compound type TI2 to Tests
HAR DIN VDE 0207-363-3 / DIN EN 50363-3 PVC self-extinguishing and flame retardant
flexing -5C to +70C and class 43 acc. to UL-Std.1581 acc. to DIN VDE 0482-332-1-2,
fixed installation -40C to +70C Core identification to DIN VDE 0293 DIN EN 60332-1-2/IEC 60332-1 (equivalent
UL/CSA black cores with continuous white DIN VDE 0472 part 804 test method B),
flexing -5C to +90C numbering UL VW-1, CSA FT1
fixed installation -40C to +90C GN-YE conductor, 3 cores and above Oil resistant to DIN VDE 0473-811-404/
Nominal voltage in the outer layer DIN EN 60811-404, UL-Std.1581 part
HAR U0/U 300/500 V Cores stranded in layers with optimal 50.182
UL/CSA 600 V lay-length
Test voltage 3000 V Outer sheath of oil resistant special PVC Note
Breakdown voltage min. 6000 V compound type TM5 to G = with green-yellow conductor
Insulation resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1 x = without green-yellow conductor (OZ)
min. 20 MOhm x km and class 43 acc. to UL-Std.1581 AWG sizes are approximate equivalent
Minimum bending radius Sheath colour grey (RAL 7001) values. The actual cross-section is in mm.
flexing 7,5x cable with meter marking screened analogue type:
fixed installation 4x cable JZ-603-CY, confer page 375
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control
systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry,
moist and wet rooms but not for open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
83704 2 x 0,5 20 5,8 9,6 52,0 83679 34 G 1 18 20,3 326,0 742,0
83650 3 G 0,5 20 6,1 14,0 63,0 83680 41 G 1 18 22,4 394,0 885,0
83651 4 G 0,5 20 6,7 19,0 69,0 83681 50 G 1 18 24,3 480,0 1071,0
83652 5 G 0,5 20 7,3 24,0 87,0 83682 61 G 1 18 26,8 586,0 1265,0
83653 7 G 0,5 20 8,8 34,0 119,0 83707 2 x 1,5 16 7,4 28,8 91,0
83654 12 G 0,5 20 11,1 58,0 198,0 83683 3 G 1,5 16 8,0 43,0 110,0
83655 18 G 0,5 20 12,9 86,0 266,0 83684 4 G 1,5 16 8,7 58,0 141,0
83656 25 G 0,5 20 16,0 120,0 380,0 83685 5 G 1,5 16 9,8 72,0 167,0
83657 34 G 0,5 20 17,7 163,0 508,0 83686 7 G 1,5 16 11,9 101,0 225,0
83658 41 G 0,5 20 19,5 197,0 594,0 83687 12 G 1,5 16 14,5 173,0 361,0
83659 50 G 0,5 20 21,3 240,0 715,0 83688 18 G 1,5 16 17,4 259,0 518,0
83660 61 G 0,5 20 23,8 293,0 840,0 83689 25 G 1,5 16 21,3 360,0 730,0
83705 2 x 0,75 19 6,1 14,4 66,0 83690 34 G 1,5 16 24,1 490,0 945,0
83661 3 G 0,75 19 6,5 22,0 76,0 83691 41 G 1,5 16 26,2 591,0 1135,0
83662 4 G 0,75 19 7,1 29,0 85,0 83692 50 G 1,5 16 28,8 720,0 1381,0
83663 5 G 0,75 19 7,9 36,0 113,0 83693 61 G 1,5 16 31,5 878,0 1640,0
83664 7 G 0,75 19 9,5 50,0 144,0 83708 2 x 2,5 14 9,1 48,0 125,0
83665 12 G 0,75 19 11,6 86,0 245,0 83694 3 G 2,5 14 9,9 72,0 169,0
83666 18 G 0,75 19 13,9 130,0 327,0 83695 4 G 2,5 14 11,0 96,0 209,0
83667 25 G 0,75 19 17,1 180,0 466,0 83696 5 G 2,5 14 12,0 120,0 256,0
83668 34 G 0,75 19 19,1 245,0 626,0 83697 7 G 2,5 14 14,6 168,0 340,0
83669 41 G 0,75 19 20,9 296,0 747,0 83698 12 G 2,5 14 18,1 288,0 579,0
83670 50 G 0,75 19 23,0 360,0 896,0 83699 18 G 2,5 14 22,1 432,0 851,0
83671 61 G 0,75 19 25,3 439,0 1070,0 83700 25 G 2,5 14 26,5 600,0 1175,0
83706 2x1 18 6,4 19,2 70,0 83701 34 G 2,5 14 29,9 816,0 1529,0
83672 3G1 18 6,8 29,0 88,0 83702 50 G 2,5 14 35,2 1200,0 2290,0
83673 4G1 18 7,5 39,0 99,0 83703 61 G 2,5 14 38,4 1464,0 2724,0
83674 5G1 18 8,4 48,0 132,0
83675 7G1 18 10,0 67,0 170,0
83676 12 G 1 18 12,5 115,0 285,0
83677 18 G 1 18 14,7 173,0 405,0
83678 25 G 1 18 18,0 240,0 570,0

Dimensions and specifications may be changed without prior notice. (RN01)

358
Cables according to international Approvals / PVC-Control Cables UL/CSA

TRAYCONTROL 500 flexible, oil-resistant, open installation


TC-ER, PLTC-ER, ITC-ER, NFPA 79 Edition 2012

Technical data Cable structure Properties


PVC control cable acc. to Bare copper conductor, fine wire self-extinguishing and flame retardant
UL-Std.1277 and UL-Std.2277 with AWG dimensions acc. to CSA FT4
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -5C to +90C with transparent nylon skin cadmium-free and contain no silicone
fixed installation -40C to +90C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage black cores with continuous white the wetting properties of lacquers
TC 600 V numbering Tests
AWM 1000 V GN-YE conductor, 3 cores and above UL:TC-ER, PLTC-ER (AWG 18 - AWG 12),
TC Wind Turbine (WTTC) 1000 V in the outer layer ITC-ER (AWG 18 - AWG 12), MTW, NFPA 79
Test voltage 3000 V Cores stranded in layers with optimal 2012, WTTC 1000V, DP-1, OIL RES I & II,
Minimum bending radius lay-length 90C dry / 75C wet, Class 1 Div. 2
flexing 4x cable Separator per NEC Art. 336, 392, 501, crush impact
Insulation resistance Outer sheath of special PVC test acc. to UL 1277
min. 20 MOhm x km Sheath colour grey (RAL 7001) CSA:
Radiation resistance With lenght marking in feet c(UL) CIC-TC FT4, CSA AWM I/II A/B FT4
up to 80x106 cJ/kg (up to 80 Mrad)
Note
Advantages
Highly-flexible, easy to install
Available on request
with blue cores (DC)
with red cores (AC)
Black or TPE outer sheath

Application
HELUKABEL TRAYCONTROL 500 is a flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this cable
to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 edition 2012. Approved for open, unprotected
installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life for industrial applications in dry,
damp and wet environments. Recommended applications: production lines, bottling plants, machine construction, switch cabinets, conveyor systems,
packaging machines, automotive industry.
N
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
63079 0,507 2 x 20 6,6 9,8 58,0 63107 1,31 2 x 16 7,8 25,2 80,0
63080 0,507 3 x 20 7,0 14,6 61,0 63108 1,31 3 x 16 8,2 37,8 86,0
63081 0,507 4 x 20 7,5 19,5 76,0 63109 1,31 4 x 16 8,8 50,3 115,0
63082 0,507 5 x 20 8,1 24,4 89,0 63110 1,31 5 x 16 9,6 62,9 126,0
63083 0,507 7 x 20 8,7 34,1 120,0 63112 1,31 6 x 16 10,2 75,5 164,0
63084 0,507 9 x 20 9,8 43,8 201,0 63113 1,31 7 x 16 10,5 88,0 171,0
63085 0,507 12 x 20 10,1 58,4 250,0 63114 1,31 8 x 16 11,1 100,7 201,0
63086 0,507 18 x 20 12,9 87,6 295,0 63115 1,31 9 x 16 12,0 113,2 237,0
63087 0,507 25 x 20 15,7 121,7 362,0 63116 1,31 10 x 16 12,4 125,8 259,0
63088 0,963 2 x 18 7,3 18,5 68,0 63117 1,31 12 x 16 13,6 151,0 301,0
63089 0,963 3 x 18 7,6 27,8 88,0 63118 1,31 14 x 16 14,5 176,1 365,0
63090 0,963 4 x 18 8,2 37,0 98,0 63119 1,31 15 x 16 15,2 188,7 379,0
63091 0,963 5 x 18 8,9 46,3 116,0 63120 1,31 16 x 16 16,0 201,3 405,0
63092 0,963 7 x 18 9,6 64,8 149,0 63121 1,31 18 x 16 16,4 226,4 443,0
63093 0,963 9 x 18 11,0 83,2 186,0 63122 1,31 19 x 16 16,6 239,0 458,0
63094 0,963 10 x 18 11,6 92,5 199,0 63123 1,31 20 x 16 17,2 251,6 491,0
63095 0,963 12 x 18 12,2 111,0 245,0 63124 1,31 25 x 16 18,9 314,5 564,0
63096 0,963 15 x 18 13,5 138,7 292,0 63125 1,31 27 x 16 19,3 339,6 629,0
63097 0,963 16 x 18 13,6 147,9 306,0 63126 1,31 30 x 16 20,0 377,3 701,0
63098 0,963 18 x 18 15,0 166,4 366,0 63127 1,31 34 x 16 22,5 427,6 775,0
63099 0,963 19 x 18 15,1 175,7 384,0 63128 1,31 40 x 16 23,5 503,1 946,0
63100 0,963 25 x 18 17,4 231,2 451,0 63129 1,31 41 x 16 24,0 515,7 967,0
63101 0,963 27 x 18 17,7 249,6 521,0 63130 1,31 50 x 16 26,1 628,8 1137,0
63102 0,963 34 x 18 19,7 314,4 625,0 63131 1,31 61 x 16 27,5 767,2 1345,0
63103 0,963 37 x 18 20,1 342,0 684,0 63132 2,08 2 x 14 8,9 40,0 100,0
63104 0,963 41 x 18 21,0 379,0 744,0 63133 2,08 3 x 14 9,2 60,0 112,0
63105 0,963 50 x 18 24,0 462,3 933,0 63111 2,08 4 x 14 10,1 80,0 141,0
63106 0,963 61 x 18 25,2 564,0 1095,0 63164 2,08 5 x 14 10,9 100,0 152,0

Continuation

359
Cables according to international Approvals / PVC-Control Cables UL/CSA

TRAYCONTROL 500 flexible, oil-resistant, open installation


TC-ER, PLTC-ER, ITC-ER, NFPA 79 Edition 2012
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
63165 2,08 6 x 14 11,5 120,0 205,0 63188 5,26 4 x 10 15,0 202,0 387,0
63166 2,08 7 x 14 12,0 140,0 216,0 63189 5,26 5 x 10 16,3 252,5 473,0
63167 2,08 9 x 14 14,7 180,0 312,0 63190 5,26 7 x 10 17,7 353,5 607,0
63168 2,08 10 x 14 15,8 200,0 378,0 63191 5,26 9 x 10 20,6 454,5 771,0
63169 2,08 12 x 14 16,4 240,0 434,0 63192 5,26 12 x 10 24,1 606,0 1061,0
63170 2,08 16 x 14 18,0 320,0 550,0 63193 5,26 19 x 10 27,2 959,5 1528,0
63171 2,08 18 x 14 18,9 359,0 616,0 63194 8,37 3 x 8 17,0 241,1 420,0
63172 2,08 19 x 14 19,0 380,0 634,0 63195 8,37 4 x 8 19,2 321,4 662,0
63173 2,08 25 x 14 23,0 500,0 817,0 63196 8,37 5 x 8 21,0 401,8 784,0
63174 3,31 2 x 12 9,7 63,0 132,0 63197 13,3 3 x 6 19,5 383,1 701,0
63175 3,31 3 x 12 10,2 95,0 177,0 63198 13,3 4 x 6 22,4 510,7 908,0
63176 3,31 4 x 12 11,2 127,0 201,0 63199 13,3 5 x 6 24,5 638,4 1149,0
63177 3,31 5 x 12 12,3 159,0 274,0 62802 21,2 3 x 4 24,4 610,6 1061,0
63178 3,31 6 x 12 13,6 191,0 315,0 62803 21,2 4 x 4 27,0 814,1 1366,0
63179 3,31 7 x 12 13,9 222,0 353,0 62804 21,2 5 x 4 29,9 1017,6 1631,0
63180 3,31 9 x 12 16,4 286,0 476,0 62805 33,6 3 x 2 28,2 967,7 1480,0
63181 3,31 12 x 12 18,3 381,0 613,0 62806 33,6 4 x 2 31,4 1290,3 1922,0
63182 3,31 16 x 12 19,8 508,0 783,0 62807 33,6 5 x 2 34,6 1612,8 2363,0
63183 3,31 19 x 12 22,3 604,0 918,0 62808 42,3 4 x 1 35,6 1624,0 2397,0
63184 3,31 20 x 12 23,1 636,0 961,0 62809 52,9 4 x 1/0 38,7 2031,0 2938,0
63185 3,31 25 x 12 25,8 794,0 1236,0 62810 67,3 4 x 2/0 42,1 2584,0 3559,0
63186 5,26 2 x 10 12,2 101,0 213,0 62811 84,4 4 x 3/0 49,4 3256,0 4181,0
63187 5,26 3 x 10 12,9 151,5 283,0 62812 106,7 4 x 4/0 52,0 4097,0 5747,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

360
Cables according to international Approvals / PVC-Control Cables UL/CSA

TRAYCONTROL 530 flexible TC-ER control cable with coloured cores

Technical data Cable structure Properties


Flexible PVC tray cable to Bare copper conductor, fine wire with self-extinguishing and flame retardant
UL-Std.1277 and UL-Std.2277 AWG dimensions acc. to CSA FT4
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -5C to +90C with transparent nylon skin cadmium-free and contain no silicone
fixed installation -40C to +90C Core identification and free from substances harmful to
Nominal voltage 2 cores = blue-with the wetting properties of lacquers
TC 600 V from 3 cores = blue cores with Tests
AWM 1000 V continuous white numbering UL: TC-ER, PLTC-ER (AWG 18 - AWG 12),
TC Wind Turbine (WTTC) 1000 V GN-YE conductor, 3 cores and above ITC-ER (AWG 18 - AWG 12), MTW, NFPA 79
Test voltage 3000 V in the outer layer 2012, WTTC 1000V, DP-1, OIL RES I & II,
Minimum bending radius Conductor cabled with non-wicking fillers 90C dry / 75C wet, Class 1 Div. 2 per NEC
5x cable Separator Art. 336, 392, 501, crush impact test in
Outer sheath of special PVC accordance with UL 1277
Sheath colour grey (RAL 7001) CSA:
c(UL) CIC-TC FT4
CSA AWM I/II
A/B FT4

Note
Available on request
with red, black, yellow or orange cores
Black or TPE outer sheath

Application
TRAYCONTROL 530 is a flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this cable to be used as a
connecting cable for AC, DC or control wiring in accordance with NFPA 79 Edition 2012. Approved for open, unprotected installation in cable trays
to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life for industrial applications in dry, damp and wet environments.
Recommended Applications: automotive industry, machine tool, production lines.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
N
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
66840 2x1 18 7,0 19,0 68,0 66862 2 x 1,32 16 7,5 25,0 80,0
66841 3G1 18 7,1 29,0 88,0 66863 3 G 1,32 16 7,8 38,0 86,0
66842 4G1 18 8,0 38,0 98,0 66864 4 G 1,32 16 8,5 51,0 115,0
66843 5G1 18 8,6 48,0 116,0 66865 5 G 1,32 16 9,3 63,0 126,0
66844 7G1 18 9,3 67,0 149,0 66866 7 G 1,32 16 10,1 89,0 171,0
66845 9G1 18 10,7 86,0 186,0 66867 9 G 1,32 16 11,7 114,0 237,0
66846 10 G 1 18 11,6 96,0 199,0 66868 10 G 1,32 16 12,4 127,0 259,0
66847 12 G 1 18 11,9 115,0 245,0 66869 12 G 1,32 16 12,9 152,0 301,0
66848 15 G 1 18 13,2 144,0 292,0 66870 15 G 1,32 16 15,0 190,0 379,0
66849 16 G 1 18 13,3 154,0 306,0 66871 16 G 1,32 16 15,2 203,0 405,0
66850 18 G 1 18 14,6 173,0 366,0 66872 18 G 1,32 16 15,9 228,0 443,0
66851 19 G 1 18 14,7 182,0 384,0 66873 19 G 1,32 16 16,0 241,0 458,0
66852 25 G 1 18 17,0 240,0 451,0 66874 25 G 1,32 16 18,6 317,0 564,0
66853 27 G 1 18 17,4 259,0 521,0 66875 27 G 1,32 16 19,0 342,0 629,0
66854 33 G 1 18 18,7 317,0 590,0 66876 33 G 1,32 16 20,4 418,0 758,0
66855 34 G 1 18 19,3 326,0 625,0 66877 34 G 1,32 16 20,5 431,0 775,0
66856 41 G 1 18 20,7 394,0 744,0 66878 41 G 1,32 16 23,4 520,0 967,0
66857 42 G 1 18 20,8 403,0 758,0 66879 42 G 1,32 16 24,1 532,0 972,0
66858 49 G 1 18 23,0 470,0 917,0 66880 49 G 1,32 16 25,5 621,0 1132,0
66859 50 G 1 18 23,5 480,0 933,0 66881 50 G 1,32 16 25,6 634,0 1137,0
66860 61 G 1 18 24,9 624,0 1095,0 66882 61 G 1,32 16 27,2 773,0 1345,0
66861 65 G 1 18 25,6 624,0 1125,0 66883 65 G 1,32 16 28,5 824,0 1376,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

361
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-600 UL/CSA flexible, number coded, 1000 V, meter marking

Technical data Cable structure Properties


Special PVC control cables adapted to Bare copper-conductor, to Extensively oil resistant, oil-/ chemical
DIN VDE 0276 part 627, DIN VDE 0295 cl.5, fine-wire, Resistance - see table Technical
DIN VDE 0285-525-2-51/ BS 6360 cl.5, IEC 60228 cl.5 Informations
DIN EN 50525-2-51, with insulation Core insulation of special PVC UV-resistant (building with black sheath)
thickness for 1 kV type and to compound type TI2 to The materials used in manufacture are
UL-Std.758 Style 21179 DIN VDE 0207-363-3 / DIN EN 50363-3 cadmium-free and contain no silicone
Temperature range and class 43 acc. to UL-Std.1581 and free from substances harmful to
flexing -5C to +80C Core identification to DIN VDE 0293 the wetting properties of lacquers
fixed installation -40C to +80C black cores with continuous white Tests
Nominal voltage numbering PVC self-extinguishing and flame retardant
VDE U0/U 600/1000 V GN-YE conductor, 3 cores and above acc. to DIN VDE 0482-332-1-2,
UL/CSA 1000 V in the outer layer DIN EN 60332-1-2/IEC 60332-1 (equivalent
Test voltage 4000 V Cores stranded in layers with DIN VDE 0472 part 804 test method B)
Breakdown voltage min. 8000 V optimal lay-length UL VW1, CSA FT1
Insulation resistance Outer sheath of special PVC
min. 20 MOhm x km compound type TM2 to Note
Minimum bending radius DIN VDE 0207-363-4-1/DIN EN 50363-4-1 G = with green-yellow conductor
flexing 7,5x cable and class 43 acc. to UL-Std.1581 x = without green-yellow conductor (OZ)
fixed installation 4x cable Sheath colour black (RAL 9005) AWG sizes are approximate equivalent
Radiation resistance or grey (RAL 7001) values. The actual cross-section is in mm.
up to 80x106 cJ/kg (up to 80 Mrad) with meter marking screened analogue type:
JZ-600-Y-CY UL/CSA, confer page 378

Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning
and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be
used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable
has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The
black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
11815 2 x 0,5 20 6,4 9,6 56,0 11880 2 x 0,5 20 6,4 9,6 56,0
11816 3 G 0,5 20 6,8 14,4 68,0 11881 3 G 0,5 20 6,8 14,4 68,0
11817 4 G 0,5 20 7,6 19,0 100,0 11882 4 G 0,5 20 7,6 19,0 100,0
11818 5 G 0,5 20 8,2 24,0 117,0 11883 5 G 0,5 20 8,2 24,0 117,0
11819 7 G 0,5 20 9,8 33,6 138,0 11884 7 G 0,5 20 9,8 33,6 138,0
11820 12 G 0,5 20 12,2 58,0 200,0 11885 12 G 0,5 20 12,2 58,0 200,0
11821 18 G 0,5 20 14,4 86,0 276,0 11886 18 G 0,5 20 14,4 86,0 276,0
11822 25 G 0,5 20 17,2 120,0 335,0 11887 25 G 0,5 20 17,2 120,0 335,0
11823 2 x 0,75 19 6,8 14,4 66,0 11888 2 x 0,75 19 6,8 14,4 66,0
11824 3 G 0,75 19 7,2 21,6 74,0 11889 3 G 0,75 19 7,2 21,6 74,0
11825 4 G 0,75 19 8,0 29,0 126,0 11890 4 G 0,75 19 8,0 29,0 126,0
11826 5 G 0,75 19 8,8 36,0 140,0 11891 5 G 0,75 19 8,8 36,0 140,0
11827 7 G 0,75 19 10,7 50,0 190,0 11892 7 G 0,75 19 10,7 50,0 190,0
11828 12 G 0,75 19 13,1 86,0 257,0 11893 12 G 0,75 19 13,1 86,0 257,0
11829 18 G 0,75 19 15,6 130,0 362,0 11894 18 G 0,75 19 15,6 130,0 362,0
11830 25 G 0,75 19 18,9 180,0 486,0 11895 25 G 0,75 19 18,9 180,0 486,0
11831 2x1 18 7,4 19,2 80,0 11896 2x1 18 7,4 19,2 80,0
11832 3G1 18 8,0 29,2 96,0 11897 3G1 18 8,0 29,2 96,0
11833 4G1 18 8,8 38,4 100,0 11898 4G1 18 8,8 38,4 100,0
11834 5G1 18 9,8 48,0 130,0 11899 5G1 18 9,8 48,0 130,0
11835 7G1 18 11,7 67,0 170,0 11900 7G1 18 11,7 67,0 170,0
11836 12 G 1 18 14,5 115,0 290,0 11901 12 G 1 18 14,5 115,0 290,0
11837 18 G 1 18 17,3 173,0 405,0 11902 18 G 1 18 17,3 173,0 405,0
11838 25 G 1 18 21,1 240,0 570,0 11903 25 G 1 18 21,1 240,0 570,0
11839 2 x 1,5 16 8,4 29,0 95,0 11904 2 x 1,5 16 8,4 29,0 95,0
11840 3 G 1,5 16 9,1 43,0 112,0 11905 3 G 1,5 16 9,1 43,0 112,0
11841 4 G 1,5 16 9,9 58,0 139,0 11906 4 G 1,5 16 9,9 58,0 139,0
11842 5 G 1,5 16 11,0 72,0 170,0 11907 5 G 1,5 16 11,0 72,0 170,0
11843 7 G 1,5 16 13,3 101,0 225,0 11908 7 G 1,5 16 13,3 101,0 225,0
11844 12 G 1,5 16 16,6 173,0 370,0 11909 12 G 1,5 16 16,6 173,0 370,0
11845 18 G 1,5 16 19,7 259,0 520,0 11910 18 G 1,5 16 19,7 259,0 520,0
11846 25 G 1,5 16 23,9 360,0 730,0 11911 25 G 1,5 16 23,9 360,0 730,0

Continuation

362
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-600 UL/CSA flexible, number coded, 1000 V, meter marking


Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
11847 2 x 2,5 14 9,4 48,0 160,0 11912 2 x 2,5 14 9,4 48,0 160,0
11848 3 G 2,5 14 9,9 72,0 175,0 11913 3 G 2,5 14 9,9 72,0 175,0
11849 4 G 2,5 14 11,1 96,0 203,0 11914 4 G 2,5 14 11,1 96,0 203,0
11850 5 G 2,5 14 12,4 120,0 251,0 11915 5 G 2,5 14 12,4 120,0 251,0
11851 7 G 2,5 14 15,0 168,0 330,0 11916 7 G 2,5 14 15,0 168,0 330,0
11852 12 G 2,5 14 18,4 288,0 553,0 11917 12 G 2,5 14 18,4 288,0 553,0
11853 18 G 2,5 14 22,0 432,0 795,0 11918 18 G 2,5 14 22,0 432,0 795,0
11854 25 G 2,5 14 26,9 600,0 1110,0 11919 25 G 2,5 14 26,9 600,0 1110,0
11855 2x4 12 11,4 77,0 180,0 11920 2x4 12 11,4 77,0 180,0
11856 3G4 12 12,3 115,0 230,0 11921 3G4 12 12,3 115,0 230,0
11857 4G4 12 13,8 154,0 310,0 11922 4G4 12 13,8 154,0 310,0
11858 5G4 12 15,3 192,0 410,0 11923 5G4 12 15,3 192,0 410,0
11859 7G4 12 16,8 269,0 540,0 11924 7G4 12 16,8 269,0 540,0
11860 12 G 4 12 22,9 461,0 860,0 11925 12 G 4 12 22,9 461,0 860,0
11861 3G6 10 14,1 173,0 370,0 11926 3G6 10 14,1 173,0 370,0
11862 4G6 10 15,6 230,0 430,0 11927 4G6 10 15,6 230,0 430,0
11863 5G6 10 17,3 288,0 650,0 11928 5G6 10 17,3 288,0 650,0
11864 7G6 10 19,3 403,0 860,0 11929 7G6 10 19,3 403,0 860,0
11865 3 G 10 8 16,5 288,0 660,0 11930 3 G 10 8 16,5 288,0 660,0
11866 4 G 10 8 18,1 384,0 790,0 11931 4 G 10 8 18,4 384,0 790,0
11867 5 G 10 8 20,5 480,0 960,0 11932 5 G 10 8 20,5 480,0 960,0
11868 7 G 10 8 22,5 672,0 1300,0 11933 7 G 10 8 22,5 672,0 1300,0
11869 3 G 16 6 19,6 461,0 760,0 11934 3 G 16 6 19,6 461,0 760,0
11870 4 G 16 6 21,7 614,0 1100,0 11935 4 G 16 6 21,7 614,0 1100,0
11871 5 G 16 6 24,2 768,0 1600,0 11936 5 G 16 6 24,2 768,0 1600,0
11872 7 G 16 6 25,7 1075,0 1890,0 11937 7 G 16 6 25,7 1075,0 1890,0
11873 3 G 25 4 24,0 720,0 1450,0 11938 3 G 25 4 24,0 720,0 1450,0
11874 4 G 25 4 26,9 960,0 1600,0 11939 4 G 25 4 26,9 960,0 1600,0
11875 5 G 25 4 29,4 1200,0 2050,0 11940 5 G 25 4 29,3 1200,0 2050,0
11876 7 G 25 4 32,8 1680,0 2900,0 11941 7 G 25 4 32,6 1680,0 2900,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

363
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-604 TC TRAY CABLE PVC power cable, exposed run, NFPA79


Edition 2012, 90C, 600 V, meter marking

Technical data Cable structure Properties


PVC power cable to UL-Std.1277 Bare copper, fine wire conductors, self-extinguishing and flame retardant
TRAY CABLE acc. to DIN VDE 0295 cl.5, BS 6360 acc. to CSA FT4
Multinorm cl.5 and IEC 60228 cl.5 The materials used in manufacture are
The TRAY CABLE also conforms to the Core insulation of special PVC class 12 B cadmium-free and contain no silicone
following standards: to tab. 50.155 UL-standard 1581, and free from substances harmful to
AWM-Style 2587 to UL-Std.758 and type TFF acc. to UL-Std. 62(AWG 20-AWG the wetting properties of lacquers
CSA C22.2 No 210 I/II A/B 90C 600 V 16) uv-resistant
Temperature range type THHW acc. to UL-Std. 83 (AWG 14)
dry environment Core identification to DIN VDE 0293 Note
flexing -5C to +90C black cores with continuous white G = with green-yellow conductor
fixed installation -25C to +90C numbering x = without green-yellow conductor (OZ)
wet environment GN-YE conductor, 3 cores and above AWG sizes are approximate equivalent
flexing -5C to +75C in the outer layer values. The actual cross-section is in mm.
fixed installation -25C to +75C Cores stranded in layers with optimal screened analogue type:
Nominal voltage UL 600 V lay-length JZ-604-FCY TC TRAY CABLE,
Test voltage 3000 V Outer sheath of special PVC confer page 380
Breakdown voltage min. 6000 V acc. to UL-Std.1277 tab.11.2 JZ-604-YCY TC TRAY CABLE,
Insulation resistance Sheath colour black (RAL 9005) confer page 381
min. 20 MOhm x km with meter marking
Minimum bending radius
7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
USA NFPA79, edition 2012 conformant flexible power cables up to 600 V, for all machinery in tool and plant constuction, suitable for installation in
dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation from the cable rack
to machines and industrial plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
69661 2x1 18 8,0 19,2 72,0 69689 2 x 2,5 14 9,4 48,0 108,0
69662 3G1 18 8,4 29,0 84,0 69690 3 G 2,5 14 9,9 72,0 137,0
69663 4G1 18 9,1 39,0 96,0 69691 4 G 2,5 14 10,8 96,0 157,0
69664 5G1 18 10,0 48,0 114,0 69692 5 G 2,5 14 11,8 120,0 190,0
69665 7G1 18 11,7 67,0 147,0 69693 7 G 2,5 14 14,7 168,0 253,0
69666 9G1 18 12,6 84,0 172,0 69694 8 G 2,5 14 16,0 192,0 339,0
69667 10 G 1 18 14,3 96,0 206,0 69695 9 G 2,5 14 16,0 216,0 341,0
69668 12 G 1 18 14,7 115,0 256,0 69696 10 G 2,5 14 17,1 240,0 392,0
69669 18 G 1 18 17,1 173,0 367,0 69697 12 G 2,5 14 17,7 288,0 470,0
69670 25 G 1 18 20,3 240,0 477,0 69698 18 G 2,5 14 20,8 432,0 682,0
69671 34 G 1 18 23,7 326,0 551,0 69699 25 G 2,5 14 25,8 600,0 891,0
69672 50 G 1 18 26,1 480,0 959,0 69700 3G4 12 11,0 115,0 187,0
69673 2 x 1,5 16 8,4 28,8 88,0 69701 4G4 12 12,0 154,0 226,0
69674 3 G 1,5 16 8,8 43,0 102,0 69702 5G4 12 13,2 192,0 280,0
69675 4 G 1,5 16 9,6 58,0 119,0 69703 7G4 12 16,5 269,0 390,0
69676 5 G 1,5 16 10,5 72,0 144,0 69704 9G4 12 17,8 346,0 480,0
69677 7 G 1,5 16 12,3 101,0 192,0 69705 12 G 4 12 19,9 461,0 841,0
69678 8 G 1,5 16 13,3 115,0 213,0 69706 18 G 4 12 24,2 691,0 981,0
69679 9 G 1,5 16 13,3 130,0 261,0 69707 3G6 10 12,5 173,0 290,0
69680 10 G 1,5 16 15,1 144,0 294,0 69708 4G6 10 14,5 230,0 381,0
69681 12 G 1,5 16 15,6 173,0 328,0 69709 5G6 10 15,8 288,0 465,0
69682 16 G 1,5 16 17,1 230,0 402,0 69710 7G6 10 17,3 403,0 654,0
69683 18 G 1,5 16 18,2 259,0 427,0 69711 3 G 10 8 16,9 288,0 511,0
69684 25 G 1,5 16 22,7 360,0 594,0 69712 4 G 10 8 18,6 384,0 584,0
69685 34 G 1,5 16 25,3 489,0 714,0 69713 5 G 10 8 20,4 480,0 781,0
69686 41 G 1,5 16 27,0 590,0 803,0 69714 7 G 10 8 23,5 672,0 970,0
69687 50 G 1,5 16 27,3 720,0 1021,0
69688 61 G 1,5 16 29,4 878,0 1238,0

Continuation

364
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-604 TC TRAY CABLE PVC power cable, exposed run, NFPA79


Edition 2012, 90C, 600 V, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
69715 3 G 16 6 21,0 461,0 651,0 69729 3 G 70 2/0 37,6 2016,0 2831,0
69716 4 G 16 6 23,9 614,0 866,0 69730 4 G 70 2/0 42,0 2688,0 3494,0
69717 5 G 16 6 26,3 768,0 1117,0 69731 5 G 70 2/0 47,6 3360,0 4260,0
69718 7 G 16 6 28,8 1075,0 1364,0 69732 3 G 95 3/0 41,8 2736,0 5010,0
69719 3 G 25 4 24,9 720,0 1090,0 69733 4 G 95 3/0 47,0 3648,0 6104,0
69720 4 G 25 4 27,2 960,0 1421,0 69734 5 G 95 3/0 52,5 4560,0 7891,0
69721 5 G 25 4 30,3 1200,0 1611,0 69735 3 G 120 4/0 46,0 3456,0 5940,0
69722 7 G 25 4 33,1 1680,0 1943,0 69736 4 G 120 4/0 51,5 4608,0 7604,0
69723 3 G 35 2 27,1 1008,0 1734,0 69737 5 G 120 4/0 56,5 5760,0 8751,0
69724 4 G 35 2 29,8 1344,0 2011,0
69725 5 G 35 2 33,0 1680,0 2347,0
69726 3 G 50 1 33,2 1440,0 2041,0
69727 4 G 50 1 36,7 1920,0 2539,0
69728 5 G 50 1 41,5 2400,0 2894,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

365
Cables according to international Approvals / PVC-Control Cables UL/CSA

TRAYCONTROL 600 flexible, oil-resistant, open installation


(TC-ER), NFPA 79 Edition 2012

Technical data Cable structure Properties


PVC-power cable according to Bare copper-conductor, fine wire self-extinguishing and flame retardant
UL-Std.1277 and UL-Std.2277 with AWG dimensions according to CSA FT4
Temperature range Core insulation of special PVC The materials used in manufacture are
UL/CSA TC -40C to +90C with transparent nylon skin cadmium-free and contain no silicone
UL/AWM -40C to +90C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage black cores with continuous white the wetting properties of lacquers
TC 600 V numbering UV-resistant
AWM 1000 V GN-YE conductor, 3 cores and abovein Tests
WTTC 1000 V the outer layer UL:
Test voltage 3000 V Cores stranded in layers with optimal TC-ER, PLTC-ER (AWG 18 - AWG 12),
Minimum bending radius lay-length ITC-ER (AWG 18 - AWG 12),
5x cable Separator UL Type WTTC, UL Type MTW,
Insulation resistance Outer sheath of special PVC NFPA 79 2012, Oil Res I (Oil Res II also
min. 20 MOhm x km Sheath colour black (RAL 9005) available), 90 C dry / 75 C wet,
Radiation resistance With lenght marking in feet Class 1 Div. 2 per NEC Art. 336, 392, 501
up to 80x106 cJ/kg (up to 80 Mrad) CSA:
c(UL) CIC-TC FT4
CSA AWM I/II A/B FT4

Note
Advantages
TC-ER, Tray Cable Exposed Run
simple Installation
outstanding flexibility

Application
USA NFPA 79 edition 2012 conformant flexible power cables up to 600 V (WTTC 1000 V), for all machinery in tool and plant constuction, suitable
for installation in dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation
from the cable rack to machines and industrial plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62020 0,507 2 x 20 6,6 9,8 60,0 62923 1,31 4 x 16 8,8 50,3 120,0
62021 0,507 3 x 20 7,0 14,6 64,0 62924 1,31 5 x 16 9,6 62,9 130,0
62022 0,507 4 x 20 7,5 19,5 79,0 62925 1,31 6 x 16 10,2 75,5 164,0
62023 0,507 5 x 20 8,1 24,4 92,0 62926 1,31 7 x 16 10,5 88,0 188,0
62024 0,507 7 x 20 8,7 34,1 124,0 62927 1,31 8 x 16 11,1 100,7 201,0
62025 0,507 9 x 20 9,8 43,8 210,0 62928 1,31 9 x 16 12,0 113,2 238,0
62026 0,507 12 x 20 10,1 58,4 263,0 62929 1,31 10 x 16 12,4 125,8 259,0
62027 0,507 18 x 20 12,9 87,6 305,0 62930 1,31 12 x 16 13,6 151,0 301,0
62028 0,507 25 x 20 15,7 121,7 371,0 62931 1,31 14 x 16 14,5 176,1 356,0
62902 0,963 2 x 18 7,3 18,5 68,0 62932 1,31 15 x 16 15,2 188,7 379,0
62903 0,963 3 x 18 7,6 27,8 68,0 62933 1,31 16 x 16 16,0 201,3 405,0
62904 0,963 4 x 18 8,2 37,0 97,0 62934 1,31 18 x 16 16,4 226,4 430,0
62905 0,963 5 x 18 8,9 46,3 116,0 62935 1,31 19 x 16 16,6 239,0 450,0
62906 0,963 7 x 18 9,6 64,8 147,0 62936 1,31 20 x 16 17,2 251,6 481,0
62907 0,963 9 x 18 11,0 83,2 186,0 62937 1,31 25 x 16 18,9 314,5 564,0
62908 0,963 10 x 18 11,6 92,5 199,0 62938 1,31 27 x 16 19,3 339,6 629,0
62909 0,963 12 x 18 12,2 111,0 250,0 62939 1,31 30 x 16 20,0 377,3 701,0
62910 0,963 15 x 18 13,5 138,7 292,0 62940 1,31 34 x 16 22,5 427,6 775,0
62911 0,963 16 x 18 13,6 147,9 306,0 62941 1,31 40 x 16 23,5 503,1 946,0
62912 0,963 18 x 18 15,0 166,4 365,0 62942 1,31 41 x 16 24,0 515,7 967,0
62913 0,963 19 x 18 15,1 175,7 384,0 62943 1,31 50 x 16 26,1 628,8 1137,0
62914 0,963 25 x 18 17,4 231,2 480,0 62944 1,31 61 x 16 27,5 767,2 1345,0
62915 0,963 27 x 18 17,7 249,6 521,0 62945 2,08 2 x 14 8,9 40,0 100,0
62916 0,963 34 x 18 19,7 314,4 625,0 62946 2,08 3 x 14 9,2 60,0 117,0
62917 0,963 37 x 18 20,1 342,0 684,0 62947 2,08 4 x 14 10,1 80,0 141,0
62918 0,963 41 x 18 21,0 379,0 744,0 62948 2,08 5 x 14 10,9 100,0 152,0
62919 0,963 50 x 18 24,0 462,3 933,0 62949 2,08 6 x 14 11,5 120,0 216,0
62920 0,963 61 x 18 25,2 564,0 1095,0 62950 2,08 7 x 14 12,0 140,0 255,0
62921 1,31 2 x 16 7,8 25,2 80,0 62951 2,08 9 x 14 14,7 180,0 312,0
62922 1,31 3 x 16 8,2 37,8 86,0 62952 2,08 10 x 14 15,8 200,0 378,0

Continuation

366
Cables according to international Approvals / PVC-Control Cables UL/CSA

TRAYCONTROL 600 flexible, oil-resistant, open installation


(TC-ER), NFPA 79 Edition 2012
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62953 2,08 12 x 14 16,4 240,0 434,0 62975 5,26 9 x 10 20,6 454,5 771,0
62954 2,08 16 x 14 18,0 320,0 550,0 62976 5,26 12 x 10 24,1 606,0 1061,0
62955 2,08 18 x 14 18,9 359,0 616,0 62977 5,26 19 x 10 27,2 959,5 1528,0
62956 2,08 19 x 14 19,0 380,0 634,0 62978 8,37 4 x 8 19,2 321,4 615,0
62957 2,08 25 x 14 23,0 500,0 817,0 62979 8,37 5 x 8 21,0 401,8 768,0
62958 3,31 2 x 12 9,7 63,0 132,0 62980 13,3 3 x 6 19,5 383,1 700,0
62959 3,31 3 x 12 10,2 95,0 177,0 62981 13,3 4 x 6 22,4 510,7 907,0
62960 3,31 4 x 12 11,2 127,0 201,0 62982 13,3 5 x 6 24,5 638,4 1100,0
62961 3,31 5 x 12 12,3 159,0 274,0 62983 21,2 3 x 4 24,4 610,6 1061,0
62962 3,31 6 x 12 13,6 191,0 315,0 62984 21,2 4 x 4 27,0 814,1 1366,0
62963 3,31 7 x 12 13,9 222,0 353,0 62985 21,2 5 x 4 29,9 1017,6 1631,0
62964 3,31 9 x 12 16,4 286,0 476,0 62986 33,6 3 x 2 28,2 967,7 1480,0
62965 3,31 12 x 12 18,3 381,0 613,0 62987 33,6 4 x 2 31,4 1290,3 1922,0
62966 3,31 16 x 12 19,8 508,0 783,0 62988 33,6 5 x 2 34,6 1612,8 2360,0
62967 3,31 19 x 12 22,3 604,0 918,0 62989 42,3 4 x 1 35,6 1624,0 2397,0
62968 3,31 20 x 12 23,1 636,0 916,0 62990 52,9 4 x 1/0 38,7 2031,0 2938,0
62969 3,31 25 x 12 25,8 794,0 1286,0 62991 67,3 4 x 2/0 42,1 2584,0 3569,0
62970 5,26 2 x 10 12,2 101,0 213,0 62992 84,4 4 x 3/0 49,4 3256,0 4181,0
62971 5,26 3 x 10 12,9 151,5 283,0 62993 106,7 4 x 4/0 52,0 4097,0 5747,0
62972 5,26 4 x 10 15,0 202,0 387,0 62994 128,4 4 x 250 55,8 4931,0 7591,0
62973 5,26 5 x 10 16,3 252,5 473,0 kcmil
62974 5,26 7 x 10 17,7 353,5 607,0 62995 181,9 4 x 350 64,3 6985,0 8299,0
kcmil
62996 257,6 4 x 500 74,1 9892,0 11549,0
kcmil

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

367
Cables according to international Approvals / PVC-Control Cables UL/CSA

H05VV-F/SJT 300 V

Technical data Cable structure Properties


PVC control cable to Bare copper-conductor, fine-wire with The materials used in manufacture are
DIN VDE 0285-525-2-11/ AWG dimensions to UL-Std.62 cadmium-free and contain no silicone
DIN EN 50525-2-11 Core insulation of special PVC, and free from substances harmful to
IEC 60227-5 and UL-Std.62 compound type TI2 acc. to the wetting properties of lacquers
and CSA 22.2 No. 49 DIN VDE 0207-363-3/ DIN EN 50363-3 Tests
Temperature range and class 43 acc. to UL-Std.62 PVC self-extinguishing and flame retardant
HAR (tab.50.182, UL-Std.1581) acc. to DIN VDE 0482-332-1-2,
flexing -5C to +70C acc. to CSA C22.2 No 49 type SJT DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation -40C to +70C Core identification acc. to DIN VDE 0472 part 804 test method B),
UL/CSA DIN VDE 0293-308 one coloured CSA FT2
flexing -5C to +60C GN-YE conductor, 3 cores and above
fixed installation -40C to +60C Core stranded with optimal lay-length
Nominal voltage Outer sheath of PVC,
HAR U0/U 300/500 V compound type TM2 to
UL/CSA 300 V DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Test voltage 2500 V, 5 min. and class 43 acc. to UL-Std.62
Breakdown voltage min. 5000 V (tab. 50.182, UL-Std.1581)
Spark-Test 6000 V acc. to CSA-Std. C 22.2 No 49 type SJT
Insulation resistance Sheath colour black, white or grey
min. 20 MOhm x km
Minimum bending radius
7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
These flexible PVC control cables, VDE-HAR-UL-CSA approved, are designed for the export and also for the export-orientated-equipment. These
cables are especially suited to use for the appliance with medium mechanical stresses with free movement without tensile stress in households, kitchens
and offices, also for household appliances in damp and wet areas, e. g. refrigerators, washing machines, spin-driver etc. , as far as this cable is admitted
to the relevant specifications of the equipment. These cables are suited to be used for cooking and heating apparatus under the condition that cable
does not come in direct contact with hot parts of the apparatus and no other influences or heat. The cables are suitable for fixed installation in furnitures,
partition walls, decoration covering and in hollow spaces of prefabricated building parts. They are not suitable for use in open air, in industries (also
permitted to tailor workshops and of that kind) and in agriculture plants and for connecting commercial electrical tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cross- No.cores Sheath Outer Cop. Weight Part no. Cross- No.cores Sheath Outer Cop. Weight
section x colour app. mm weight app. section x colour app. mm weight app.
mm AWG-No. kg / km kg / km mm AWG-No. kg / km kg / km
28034 1,04 2 x 17 black 7,4 20,0 86,0 28042 2,63 2 x 13 black 9,5 50,5 150,0
28066 1,04 2 x 17 grey 7,4 20,0 86,0 28074 2,63 2 x 13 grey 9,5 50,5 150,0
28050 1,04 2 x 17 white 7,4 20,0 86,0 28058 2,63 2 x 13 white 9,5 50,5 150,0
28035 1,04 3 x 17 black 7,9 30,0 98,0 28043 2,63 3 x 13 black 10,2 75,7 184,0
28067 1,04 3 x 17 grey 7,9 30,0 98,0 28075 2,63 3 x 13 grey 10,2 75,7 184,0
28051 1,04 3 x 17 white 7,9 30,0 98,0 28059 2,63 3 x 13 white 10,2 75,7 184,0
28036 1,04 4 x 17 black 8,8 40,0 123,0 28044 2,63 4 x 13 black 11,2 101,0 229,0
28068 1,04 4 x 17 grey 8,8 40,0 123,0 28076 2,63 4 x 13 grey 11,2 101,0 229,0
28052 1,04 4 x 17 white 8,8 40,0 123,0 28060 2,63 4 x 13 white 11,2 101,0 229,0
28037 1,04 5 x 17 black 9,6 50,0 146,0 28045 2,63 5 x 13 black 12,5 126,2 281,0
28069 1,04 5 x 17 grey 9,6 50,0 146,0 28077 2,63 5 x 13 grey 12,5 126,2 281,0
28053 1,04 5 x 17 white 9,6 50,0 146,0 28061 2,63 5 x 13 white 12,5 126,2 281,0
28038 1,65 2 x 15 black 8,1 31,7 106,0 28046 4,17 2 x 11 black 10,8 80,1 204,0
28070 1,65 2 x 15 grey 8,1 31,7 106,0 28078 4,17 2 x 11 grey 10,8 80,1 204,0
28054 1,65 2 x 15 white 8,1 31,7 106,0 28062 4,17 2 x 11 white 10,8 80,1 204,0
28039 1,65 3 x 15 black 8,7 47,5 128,0 28047 4,17 3 x 11 black 11,6 120,1 254,0
28071 1,65 3 x 15 grey 8,7 47,5 128,0 28079 4,17 3 x 11 grey 11,6 120,1 254,0
28055 1,65 3 x 15 white 8,7 47,5 128,0 28063 4,17 3 x 11 white 11,6 120,1 254,0
28040 1,65 4 x 15 black 9,8 63,4 164,0 28048 4,17 4 x 11 black 12,8 160,1 315,0
28072 1,65 4 x 15 grey 9,8 63,4 164,0 28080 4,17 4 x 11 grey 12,8 160,1 315,0
28056 1,65 4 x 15 white 9,8 63,4 164,0 28064 4,17 4 x 11 white 12,8 160,1 315,0
28041 1,65 5 x 15 black 10,8 79,2 201,0 28049 4,17 5 x 11 black 14,4 200,2 393,0
28073 1,65 5 x 15 grey 10,8 79,2 201,0 28081 4,17 5 x 11 grey 14,4 200,2 393,0
28057 1,65 5 x 15 white 10,8 79,2 201,0 28065 4,17 5 x 11 white 14,4 200,2 393,0

Dimensions and specifications may be changed without prior notice. (RN01)

368
Cables according to international Approvals / PVC-Control Cables UL/CSA

H05VV-F/SJT 300 V

Technical data Cable structure Properties


PVC control cable to Bare copper-conductor, fine-wire with PVC self-extinguishing and flame retardant
DIN VDE 0285-525-2-11/ AWG dimensions acc. to UL-Std.62 acc. to DIN VDE 0482-332-1-2,
DIN EN 50525-2-11, IEC 60227-5 and Core insulation of PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
UL-Std.62 and CSA 22.2 No. 49 compound type TI2 to DIN VDE 0472 part 804 test method B),
Temperature range DIN VDE 0207-363-3 / DIN EN 50363-3 CSA FT2
HAR and class 43 acc. to UL-Std. 62 The materials used in manufacture are
flexing -5C to +70C (tab.50.182, UL-Std.1581) cadmium-free and contain no silicone
fixed installation -40C to +70C acc. to CSA C22.2 No 49 type SJT and free from substances harmful to
UL/CSA Core identification to the wetting properties of lacquers
flexing -5C to +60C DIN VDE 0293-308 coloured
fixed installation -40C to +60C GN-YE conductor, 3 cores and above Note
Nominal voltage Core stranded with optimal lay-length Please complete the part number for
HAR U0/U 300/500 V Outer sheath of PVC these cables by adding the suffix for
UL/CSA 300 V compound type TM2 to the colour required as per the list:
Test voltage 2500 V, 5 min. DIN VDE 0207-363-4-1/DIN EN 50363-4-1 0 = approx.RAL 5015 blue
Breakdown voltage min. 5000 V and class 43 acc. to UL-Std.62 1 = approx.RAL 6018 green
Spark-Test 6000 V (tab.50.182, UL-Std.1581) 2 = approx.RAL 8003 brown
Insulation resistance acc. to CSA-Std. C 22.2 No 49 type SJT 3 = approx.RAL 1021 yellow
min. 20 MOhm x km Sheath colour by request 4 = approx.RAL 3000 red
Minimum bending radius 5 = approx.RAL 2003 orange
7,5x cable 6 = approx.RAL 4005 violet
Radiation resistance 7 = gold
up to 80x106 cJ/kg (up to 80 Mrad) 8 = dusty gold
Further colours on request.

Application
These flexible PVC control cables, VDE-HAR-UL-CSA approved, are designed for the export and also for the export-orientated-equipment. These
cables are especially suited to use for the appliance with medium mechanical stresses with free movement without tensile stress in households, kitchens
and offices, also for household appliances in damp and wet areas, e. g. refrigerators, washing machines, spin-driver etc. , as far as this cable is admitted
to the relevant specifications of the equipment. These cables are suited to be used for cooking and heating apparatus under the condition that cable
does not come in direct contact with hot parts of the apparatus and no other influences or heat. The cables are suitable for fixed installation in furnitures, N
partition walls, decoration covering and in hollow spaces of prefabricated building parts. They are not suitable for use in open air, in industries (also
permitted to tailor workshops and of that kind) and in agriculture plants and for connecting commercial electrical tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
3110x 1,04 2 x 17 7,4 20,0 86,0 3118x 2,63 2 x 13 9,5 50,5 150,0
3111x 1,04 3 G 17 7,9 30,0 98,0 3119x 2,63 3 G 13 10,2 75,7 184,0
3112x 1,04 4 G 17 8,8 40,0 123,0 3120x 2,63 4 G 13 11,2 101,0 229,0
3113x 1,04 5 G 17 9,6 50,0 146,0 3121x 2,63 5 G 13 12,5 126,2 281,0
3114x 1,65 2 x 15 8,1 31,7 106,0 3122x 4,17 2 x 11 10,8 80,1 204,0
3115x 1,65 3 G 15 8,7 47,5 128,0 3123x 4,17 3 G 11 11,6 120,1 254,0
3116x 1,65 4 G 15 9,8 63,4 164,0 3124x 4,17 4 G 11 12,8 160,1 315,0
3117x 1,65 5 G 15 10,8 79,2 201,0 3125x 4,17 5 G 11 14,4 200,2 393,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

369
Cables according to international Approvals / PVC-Control Cables UL

H05VV-F/UL 500 V

Technical data Cable structure Properties


PVC control cable to Bare copper, fine wire to PVC self-extinguishing and flame retardant
DIN VDE 0285-525-2-11/ DIN VDE 0295 cl.5, BS 6360 cl.5, acc. to VDE 0482-332-1-2,
DIN EN 50525-2-11, IEC 60227-5 and IEC 60228 cl.5 acc. to UL-Std.62 DIN EN 60332-1-2/IEC 60332-1 (equivalent
UL-Std. 758 AWM-Style 20195 Core insulation of special PVC DIN VDE 0472 part 804 test method B)
Temperature range compound type TI2 to The materials used in manufacture are
HAR DIN VDE 0207-363-3 / DIN EN 50363-3 cadmium-free and contain no silicone
flexing -5C to +70C Core identification to DIN VDE 0293-308, and free from substances harmful to
fixed installation -40C to +70C one coloured the wetting properties of lacquers
UL Core stranded in layers with optimal
flexing -5C to +75C lay-length Note
fixed installation -40C to +75C GN-YE conductor, 3 cores and above G = with green-yellow conductor
Nominal voltage Outer sheath of special PVC x = without green-yellow conductor
HAR U0/U 300/500 V compound type TM2 to AWG sizes are approximate equivalent
UL U0/U 300/500 V DIN VDE 0207-363-4-1/DIN EN 50363-4-1 values. The actual cross-section is in mm.
Test voltage 2500 V Sheath colour by request Please complete the part number for
Breakdown voltage min. 5000 V these cables by adding the suffix for
Insulation resistance the colour required as per the list:
min. 20 MOhm x km 0 = approx.RAL 9005 black
Minimum bending radius 1 = approx.RAL 9003 white
7,5x cable 2 = approx.RAL 5015 blue
Radiation resistance 3 = approx.RAL 6018 green
up to 80x106 cJ/kg (up to 80 Mrad) 4 = approx.RAL 8003 brown
5 = approx.RAL 1021 yellow
6 = approx.RAL 3000 red
7 = approx.RAL 2003 orange
8 = approx.RAL 4005 violet
9 = approx.RAL 7001/7032 grey
Further colours on request.

Application
These flexible PVC control cables, VDE-HAR-AWM approved, are designed for the export and also for the export-orientated-equipment. These cables
are especially suited to use for the appliance with medium mechanical stresses with free movement without tensile stress in households, kitchens and
offices, also for household appliances in damp and wet areas, e. g. refrigerators, washing machines, spin-driver etc. , as far as this cable is admitted
to the relevant specifications of the equipment. These cables are suited to be used for cooking and heating apparatus under the condition that cable
does not come in direct contact with hot parts of the apparatus and no other influences or heat. The cables are suitable for fixed installation in furnitures,
partition walls, decoration covering and in hollow spaces of prefabricated building parts. They are not suitable for use in open air, in industries (also
permitted to tailor workshops and of that kind) and in agriculture plants and for connecting commercial electrical tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
3269x 2 x 0,75 18 6,4 14,4 50,0 3279x 4 G 1,5 15 9,3 58,0 117,0
3270x 3 G 0,75 18 6,8 21,6 60,0 3280x 5 G 1,5 15 10,4 72,0 144,0
3271x 4 G 0,75 18 7,4 29,0 73,0 3281x 3 G 2,5 13 10,0 72,0 152,0
3272x 5 G 0,75 18 8,3 36,0 88,0 3282x 4 G 2,5 13 10,9 96,0 192,0
3273x 2x1 17 7,3 19,0 57,0 3283x 5 G 2,5 13 12,2 120,0 243,0
3274x 3G1 17 7,8 29,0 73,0
3275x 4G1 17 8,6 38,0 85,0
3276x 5G1 17 9,4 48,0 105,0
3277x 2 x 1,5 15 7,9 29,0 82,0
3278x 3 G 1,5 15 8,4 43,0 95,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

370
Cables according to international Approvals / PVC-Control Cables

FROR CEI 20-22 II

Technical data Cable structure Properties


Special PVC-sheath flexible cord as per Bare copper conductor, fine wire stranded Oil- and petrol resistant as per CEI 20-22 II
Italian standard CEI 20-22 to CEI 20-29 cl.5 Conditionally resistant to
Temperature range Special PVC compound TI2 Oil
flexing -5C to +70C Core identification up to 4 cores to Solvents
fixed installation -35C to +70C HELUKABEL-JB colour code, Acids
Nominal voltage from 5 cores black with continuous Lyes
up to 5-cores U0/U 450/750 V white number printing The materials used in manufacture are
from 7-cores U0/U 300/500 V GN-YE conductor cadmium-free and contain no silicone
Test voltage 2000 V Cores stranded in layers with optimal and free from substances harmful to
Insulation resistance lay-length the wetting properties of lacquers
min. 20 MOhm x km Outer sheath of special PVC Tests
Radiation resistance Sheath colour grey, similar to RAL 7035, PVC self-extinguishing and flame retardant,
up to 80x106 cJ/kg (80 Mrad) with printing CEI 20-22 II test methods analog to IEC 60332-3
Minimum bending radius
10x cable Note
G = with green-yellow conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Well known companies (FIAT, COMAU, etc.) use this cable for measurement and control purposes on machine tools and conveyors, as well as on
production lines in equipment production and for special mechanical engineering. These cables are used for flexible use for medium mechanical stresses
with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. Due to special conductor
insulation- and sheath compound, this cable is flame resistant in case of fire and self-extinguishing. The good oil- and petrol resistance allows the
usage of this cable also in problem areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km

60250
60251
mm
3G1
4G1
8,5
9,5
kg / km
29,0
39,0
85,0
100,0
17
17
60287
60270
mm
3 G 2,5
4 G 2,5
11,3
12,3
kg / km
72,0
96,0
190,0
215,0
14
14
N
60252 5G1 10,5 48,0 123,0 17 60271 5 G 2,5 12,6 120,0 270,0 14
60253 7G1 10,8 67,0 160,0 17 60272 7 G 2,5 14,5 168,0 350,0 14
60254 12 G 1 13,8 115,0 270,0 17 60273 12 G 2,5 18,0 288,0 550,0 14
60255 18 G 1 16,5 173,0 380,0 17 60274 4G4 14,0 154,0 300,0 12
60256 25 G 1 19,5 240,0 500,0 17 60275 7G4 16,0 269,0 500,0 12
60284 27 G 1 20,0 259,0 560,0 17 60276 4G6 16,0 230,0 430,0 10
60285 33 G 1 20,8 317,0 700,0 17 60277 4 G 10 19,0 384,0 700,0 8
60257 34 G 1 21,0 326,0 720,0 17 60278 4 G 16 23,0 614,0 1000,0 6
60258 42 G 1 23,3 405,0 800,0 17 60279 4 G 25 28,0 960,0 1550,0 4
60259 50 G 1 25,0 480,0 1050,0 17 60280 4 G 35 31,0 1344,0 2070,0 2
60260 3 G 1,5 9,6 43,0 105,0 16 60281 4 G 50 37,0 1920,0 2850,0 1
60261 4 G 1,5 11,0 58,0 150,0 16 60282 4 G 70 43,0 2688,0 4000,0 2/0
60262 5 G 1,5 12,0 72,0 190,0 16 60283 4 G 95 50,0 3648,0 5400,0 3/0
60263 7 G 1,5 12,5 101,0 220,0 16
60264 12 G 1,5 16,0 173,0 350,0 16
60265 18 G 1,5 18,8 259,0 515,0 16
60266 25 G 1,5 23,0 360,0 705,0 16
60267 34 G 1,5 26,0 490,0 990,0 16
60286 37 G 1,5 26,5 533,0 1005,0 16
60268 42 G 1,5 29,5 605,0 1080,0 16
60269 50 G 1,5 30,5 720,0 1330,0 16

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

371
Cables according to international Approvals / PVC-Control Cables

C.N.O.M.O Type N0VV5-F according to NFC 32-206

Technical data Cable structure Properties


Special PVC based core insulation Bare copper conductor, fine wire stranded to The materials used in manufacture are
As per to the french motor industry NFC 32-013 class 5 bzw. IEC 60228 class 5 cadmium-free and contain no silicone
standard for tool machines 04-24-22 Core insulation of special PVC and free from substances harmful to
Temperature range Core indetification red or black the wetting properties of lacquers
flexing -5C to +80C cores with continuous white Tests
fixed installation -30C to +80C numbering PVC self-extinguishing and flame retardant,
Nominal voltage 500 V GN-YE conductor text method B and IEC 60332-1
Test voltage 2000 V Cores stranded in layers with Resistant to
Insulation resistance optimal lay-length Oil
min. 20 MOhm x km Outer sheath of special PVC Petrol
Radiation resistance Sheath colour gray Cutting oil acc. to C.N.O.M.O
up to 80x106 cJ/kg (80 Mrad) recommendation E 03.40.150N
Minimum bending radius (VDE 0472 part 803)
15x cable
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Further types and sizes available on
request.

Application
These cables are constructed specially for the french automobile industries and used for the installation in tool making machines, production lines,
industrial plants, air conditioning as well as for use in steel production. These cables are used for flexible use for medium mechanical stresses with free
movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
60000 2 x 0,75 6,2 14,4 50,0 18 60034 2 x 2,5 10,5 48,0 122,0 14
60001 3 G 0,75 6,6 21,6 59,0 18 60035 3 G 2,5 11,0 72,0 151,0 14
60002 4 G 0,75 7,2 29,0 72,0 18 60036 4 G 2,5 12,0 96,0 191,0 14
60003 5 G 0,75 8,0 36,0 87,0 18 60037 5 G 2,5 13,1 120,0 244,0 14
60004 6 G 0,75 8,9 50,0 105,0 18 60038 6 G 2,5 15,0 168,0 292,0 14
60005 12 G 0,75 11,6 86,0 175,0 18 60039 12 G 2,5 18,0 288,0 524,0 14
60006 18 G 0,75 13,9 144,0 267,0 18 60040 2x4 10,4 77,0 178,0 12
60007 27 G 0,75 17,2 230,0 404,0 18 60041 3G4 11,3 115,0 230,0 12
60008 36 G 0,75 19,7 288,0 503,0 18 60042 4G4 12,8 154,0 300,0 12
60009 48 G 0,75 22,8 360,0 670,0 18 60043 5G4 14,2 192,0 362,0 12
60010 60 G 0,75 24,9 439,0 805,0 18 60044 2x6 11,6 115,0 218,0 10
60011 2x1 6,5 19,0 56,0 17 60045 3G6 12,7 173,0 325,0 10
60012 3G1 6,9 29,0 72,0 17 60046 4G6 14,2 230,0 481,0 10
60013 4G1 7,7 38,0 84,0 17 60047 5G6 15,7 288,0 584,0 10
60014 5G1 8,5 48,0 104,0 17 60048 2 x 10 15,0 194,0 505,0 8
60015 6G1 9,2 67,0 124,0 17 60049 3 G 10 16,6 288,0 610,0 8
60016 12 G 1 12,4 115,0 219,0 17 60050 4 G 10 18,4 384,0 736,0 8
60017 18 G 1 15,2 192,0 314,0 17 60051 5 G 10 20,9 480,0 913,0 8
60018 27 G 1 18,7 308,0 485,0 17
60019 36 G 1 21,1 384,0 620,0 17
60020 48 G 1 24,3 480,0 809,0 17
60021 60 G 1 26,4 586,0 1000,0 17
60022 2 x 1,5 7,5 29,0 76,0 16
60023 3 G 1,5 8,1 43,0 94,0 16
60024 4 G 1,5 9,1 58,0 116,0 16
60025 5 G 1,5 10,1 72,0 143,0 16
60026 6 G 1,5 11,0 101,0 173,0 16
60027 12 G 1,5 15,1 173,0 307,0 16
60028 18 G 1,5 17,9 263,0 464,0 16
60029 24 G 1,5 21,0 341,0 629,0 16
60030 27 G 1,5 21,8 372,0 708,0 16
60031 36 G 1,5 24,5 498,0 985,0 16
60032 48 G 1,5 28,4 641,0 1175,0 16
60033 60 G 1,5 31,3 878,0 1415,0 16

Dimensions and specifications may be changed without prior notice. (RN01)

372
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-602-CY screened two approval control cable, oil resistant,


EMC-preferred type, 90C, 600 V, meter marking

Technical data Cable structure Properties


Special PVC-insulated sheathed cable Bare copper, fine wire stranded to Resistant to mineral oils, synthetic oils and
acc. to UL AWM Style 10012 (core DIN VDE 0295 cl.5, BS 6360 cl.5 and coolant. The outer sheath is approved
insulation) Style 2587 and CSA IEC 60228 cl.5 with an improved oil-resistance-test.
Temperature range Core insulation of PVC The materials used in manufacture are
flexing -5C to +90C compound type TI3 to cadmium-free and contain no silicone
fixed installation -40C to +90C DIN VDE 0207-363-3 / DIN EN 50363-3 and free from substances harmful to
Nominal voltage and class 43 acc. to UL-Std.1581 the wetting properties of lacquers
UL/CSA 600 V Core identification to DIN VDE 0293 Tests
Test voltage 3000 V black cores with continuous white PVC self-extinguishing and flame retardant
Breakdown voltage min. 6000 V numbering acc. to DIN VDE 0482-332-1-2,
Insulation resistance GN-YE conductor, 3 cores and above DIN EN 60332-1-2, IEC 60332-1 (equivalent
min. 20 MOhm x km in the outer layer DIN VDE 0472 part 804 test method B),
Minimum bending radius Cores stranded in layers with UL VW-1, CSA FT1
flexing 10x cable optimal lay-length
fixed installation 5x cable PVC-insulated inner sheath YM5 to Note
Radiation resistance DIN VDE 0207 part 5 G = with green-yellow conductor
up to 80x106 cJ/kg (up to 80 Mrad) Braided screen of tinned Cu wires approx. x = without green-yellow conductor (OZ)
Coupling resistance 85% coverage Cleanroom qualification tested with analog
max. 250 Ohm/km Outer sheath of special PVC type. Please note "cleanroom qualified"
compound type YM5 to when ordering.
DIN VDE 0207 part 5 AWG sizes are approximate equivalent
and class 43 acc. to UL-Std.1581 values. The actual cross-section is in mm.
Sheath colour grey (RAL 7001) unscreened analogue type:
with meter marking JZ-602, confer page 356

Application
UL and CSA approved flexible control cables up to 600 V, for all machinery in tooling and plant construction, suitable for installation in dry, moist or
wet environments for medium mechanical loads. Designed for the export-orientated machinery manufacturer, specifically for USA and Canada. The
thick braiding screen ensures compliance with electromagnetic requirements.
EMC = Electromagnetic compatibillity
N
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
82990 2 x 0,5 20 7,4 35,0 93,0 82977 34 G 1,5 16 25,2 629,0 1203,0
82991 3 G 0,5 20 7,7 42,0 124,0 82978 41 G 1,5 16 27,6 801,0 1588,0
82992 4 G 0,5 20 8,2 47,0 133,0 82959 2 x 2,5 14 10,1 96,0 173,0
82993 5 G 0,5 20 9,0 56,0 153,0 82960 3 G 2,5 14 10,6 144,0 220,0
82994 7 G 0,5 20 9,6 69,0 191,0 82961 4 G 2,5 14 11,6 148,0 270,0
82995 9 G 0,5 20 11,2 87,0 243,0 82962 5 G 2,5 14 12,7 181,0 329,0
82996 12 G 0,5 20 12,3 108,0 322,0 82963 7 G 2,5 14 14,0 255,0 428,0
82997 18 G 0,5 20 14,7 145,0 374,0 82964 9 G 2,5 14 16,4 309,0 580,0
82998 25 G 0,5 20 17,0 240,0 436,0 82965 12 G 2,5 14 18,1 441,0 761,0
82999 34 G 0,5 20 21,4 312,0 560,0 82966 18 G 2,5 14 22,2 570,0 1140,0
83000 41 G 0,5 20 21,4 348,0 663,0 82967 25 G 2,5 14 27,0 738,0 1551,0
82979 2x1 18 8,1 50,0 107,0 82954 2x4 12 11,2 120,0 209,0
82980 3G1 18 8,5 60,0 130,0 82955 3G4 12 11,9 174,0 310,0
82981 4G1 18 9,2 71,0 155,0 82956 4G4 12 13,3 230,0 456,0
82982 5G1 18 10,1 88,0 181,0 82957 5G4 12 14,6 273,0 532,0
82983 7G1 18 10,8 111,0 209,0 82958 7G4 12 15,9 316,0 737,0
82984 9G1 18 12,7 139,0 321,0 82949 2x6 10 12,9 173,0 318,0
82985 12 G 1 18 14,1 184,0 341,0 82950 3G6 10 14,0 240,0 411,0
82986 18 G 1 18 16,6 260,0 473,0 82951 4G6 10 15,4 305,0 572,0
82987 25 G 1 18 19,7 349,0 650,0 82952 5G6 10 17,0 439,0 732,0
82988 34 G 1 18 22,6 486,0 781,0 82953 7G6 10 18,3 505,0 961,0
82989 41 G 1 18 24,7 531,0 892,0 82945 3 G 10 8 16,3 350,0 741,0
82968 2 x 1,5 16 8,6 63,0 136,0 82946 4 G 10 8 19,4 535,0 988,0
82969 3 G 1,5 16 9,2 80,0 165,0 82947 5 G 10 8 21,6 592,0 1202,0
82970 4 G 1,5 16 10,0 97,0 192,0 82948 7 G 10 8 23,9 810,0 1743,0
82971 5 G 1,5 16 11,0 119,0 224,0 82941 3 G 16 6 23,9 585,0 1088,0
82972 7 G 1,5 16 11,8 147,0 273,0 82942 4 G 16 6 26,4 740,0 1662,0
82973 9 G 1,5 16 14,0 182,0 340,0
82974 12 G 1,5 16 15,3 267,0 461,0
82975 18 G 1,5 16 18,5 374,0 674,0
82976 25 G 1,5 16 21,8 526,0 950,0

Continuation

373
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-602-CY screened two approval control cable, oil resistant,


EMC-preferred type, 90C, 600 V, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
82943 5 G 16 6 29,6 895,0 2021,0 82918 3 G 120 4/0 52,8 3812,0 5899,0
82944 7 G 16 6 32,6 1282,0 2720,0 82919 4 G 120 4/0 58,2 5069,0 8010,0
82937 3 G 25 4 28,3 1070,0 1947,0 82920 5 G 120 4/0 63,8 5877,0 9205,0
82938 4 G 25 4 31,4 1140,0 2591,0
82939 5 G 25 4 34,6 1380,0 3197,0
82940 7 G 25 4 38,1 1870,0 4530,0
82934 3 G 35 2 31,3 1240,0 2701,0
82935 4 G 35 2 34,4 1576,0 3277,0
82936 5 G 35 2 38,1 1930,0 4530,0
82488 3 G 50 1 37,0 1675,0 2870,0
82780 4 G 50 1 40,9 2155,0 3960,0
82781 5 G 50 1 45,0 2794,0 4371,0
82782 3 G 70 2/0 42,1 2288,0 3647,0
82783 4 G 70 2/0 46,2 3120,0 4882,0
82914 5 G 70 2/0 50,9 3705,0 5876,0
82915 3 G 95 3/0 46,2 3010,0 4751,0
82916 4 G 95 3/0 50,0 4043,0 6368,0
82917 5 G 95 3/0 56,0 5026,0 7843,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS

374
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-603-CY Multi approval control cable, oil resistant,


Cu-screened, EMC-preferred, meter marking

Technical data Cable structure Properties


Special PVC control cable with oil resistant Bare copper, fine wire conductor to Oil resistant to DIN VDE 0473-811-404/
outer sheath to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, BS 6360 cl.5 and DIN EN 60811-404, UL 1581 part 50.182
DIN EN 50525-2-51 and to UL-Style 2587 IEC 60228 cl.5 The materials used in manufacture are
Temperature range Core insulation of special PVC cadmium-free and contain no silicone
HAR compound type TI2 to and free from substances harmful to
flexing -5C to +70C DIN VDE 0207-363-3 / DIN EN 50363-3 the wetting properties of lacquers
fixed installation -40C to +70C and class 43 acc. to UL-Std.1581 Tests
UL/CSA Core identification to DIN VDE 0293 PVC self-extinguishing and flame retardant
flexing -5C to +90C black cores with continuous white acc. to DIN VDE 0482-332-1-2,
fixed installation -40C to +90C numbering DIN EN 60332-1-2, IEC 60332-1 (equivalent
Nominal voltage GN-YE conductor in the outer layer DIN VDE 0472 part 804 test method B)
HAR U0/U 300/500 V Cores stranded in layers with optimal UL VW-1, CSA FT1
UL/CSA 600 V lay-lengt
Test voltage 3000 V PVC based inner sheath Note
Breakdown voltage min. 6000 V Tinned copper braiding screening, G = with green-yellow conductor
Insulation resistance 85% coverage x = without green-yellow conductor (OZ)
min. 20 MOhm x km Outer sheath of special PVC, oil resistant AWG sizes are approximate equivalent
Minimum bending radius compound type TM5 to values. The actual cross-section is in mm.
flexing 10x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1 unscreened analogue type:
fixed installation 5x cable and class 43 acc. to UL-Std.1581 JZ-603, confer page 358
Radiation resistance Sheath colour grey (RAL 7001)
up to 80x106 cJ/kg (up to 80 Mrad) with meter marking
Coupling resistance
max. 250 Ohm/km

Application
UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control
systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for medium mechanical stresses with free movements
in dry, moist and wet rooms but not for open air.
EMC = Electromagnetic compatibillity N
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
83709 2 x 0,5 20 8,0 41,0 90,0 83747 18 G 1 18 17,3 284,0 560,0
83720 3 G 0,5 20 8,3 45,0 105,0 83748 25 G 1 18 21,1 387,0 760,0
83721 4 G 0,5 20 8,9 54,0 123,0 83749 34 G 1 18 23,5 500,0 945,0
83722 5 G 0,5 20 9,7 66,0 147,0 83750 41 G 1 18 25,5 578,0 1151,0
83723 7 G 0,5 20 11,2 79,0 195,0 83751 50 G 1 18 27,6 681,0 1300,0
83724 12 G 0,5 20 13,6 137,0 276,0 83752 61 G 1 18 32,4 710,0 1500,0
83725 18 G 0,5 20 15,4 156,0 418,0 83712 2 x 1,5 16 9,6 64,0 144,0
83726 25 G 0,5 20 18,6 250,0 504,0 83753 3 G 1,5 16 10,1 82,0 160,0
83727 34 G 0,5 20 20,8 316,0 632,0 83754 4 G 1,5 16 11,0 99,0 210,0
83728 41 G 0,5 20 22,6 348,0 750,0 83755 5 G 1,5 16 12,3 123,0 240,0
83729 50 G 0,5 20 24,8 407,0 968,0 83756 7 G 1,5 16 14,2 148,0 305,0
83730 61 G 0,5 20 26,0 520,0 1068,0 83757 12 G 1,5 16 17,1 274,0 482,0
83710 2 x 0,75 19 8,3 46,0 101,0 83758 18 G 1,5 16 20,0 386,0 611,0
83731 3 G 0,75 19 8,6 57,0 127,0 83759 25 G 1,5 16 24,0 531,0 950,0
83732 4 G 0,75 19 9,4 63,0 155,0 83760 34 G 1,5 16 27,1 671,0 1200,0
83733 5 G 0,75 19 10,1 76,0 180,0 83761 41 G 1,5 16 29,7 840,0 1400,0
83734 7 G 0,75 19 11,9 100,0 225,0 83762 50 G 1,5 16 31,8 997,0 1665,0
83735 12 G 0,75 19 14,2 175,0 326,0 83763 61 G 1,5 16 34,6 1120,0 1852,0
83736 18 G 0,75 19 16,6 240,0 457,0 83713 2 x 2,5 14 11,4 110,0 189,0
83737 25 G 0,75 19 20,0 306,0 635,0 83764 3 G 2,5 14 12,0 148,0 244,0
83738 34 G 0,75 19 22,4 346,0 805,0 83765 4 G 2,5 14 13,4 169,0 296,0
83739 41 G 0,75 19 24,0 403,0 908,0 83766 5 G 2,5 14 14,6 220,0 367,0
83740 50 G 0,75 19 26,2 470,0 1155,0 83767 7 G 2,5 14 17,2 284,0 478,0
83741 61 G 0,75 19 30,0 550,0 1400,0 83768 12 G 2,5 14 21,2 470,0 622,0
83711 2x1 18 8,6 54,0 113,0 83769 18 G 2,5 14 24,8 572,0 1010,0
83742 3G1 18 9,2 64,0 144,0 83770 25 G 2,5 14 29,8 740,0 1375,0
83743 4G1 18 9,8 76,0 178,0 83771 34 G 2,5 14 33,4 1179,0 1893,0
83744 5G1 18 10,7 89,0 205,0 83772 50 G 2,5 14 39,0 1660,0 2666,0
83745 7G1 18 12,5 114,0 263,0 83773 61 G 2,5 14 41,0 1992,0 3077,0
83746 12 G 1 18 15,1 186,0 424,0

Dimensions and specifications may be changed without prior notice. (RN01)

375
Cables according to international Approvals / PVC-Control Cables UL/CSA

TRAYCONTROL 500-C flexible, oil-resistant, screened,


EMC-preferred type, open installation TC-ER, PLTC-ER, ITC-ER, NFPA 79 Edition 2012

Technical data Cable structure Properties


PVC control cable acc. to Bare copper conductor, fine wire with AWG self-extinguishing and flame retardant
UL-Std.1277 and UL-Std.2277 dimensions acc. to CSA FT4
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -5C to +90C with transparent nylon skin cadmium-free and contain no silicone
fixed installation -40C to +90C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage black cores with continuous white the wetting properties of lacquers
TC 600 V numbering Tests
AWM 1000 V GN-YE conductor, 3 cores and above UL:
TC Wind Turbine (WTTC) 1000 V in the outer layer TC-ER, PLTC-ER (AWG 18 - AWG 12),
Test voltage 3000 V Cores stranded in layers with ITC-ER (AWG 18 - AWG 12), MTW, NFPA 79
Coupling resistance optimal lay-length 2012, WTTC 1000V, DP-1, OIL RES I & II,
max. 250 Ohm/km Separating foil 90C dry / 75C wet, Class 1 Div. 2 per
Minimum bending radius Braided screening of tinned copper wires, NEC Art 336, 392, 501, crush impact test
flexing 6x cable coverage approx. 85% in accordance with UL 1277
Insulation resistance Separator CSA:
min. 20 MOhm x km Outer sheath of special PVC c(UL) CIC-TC FT4, CSA AWM I/II A/B FT4
Radiation resistance Sheath colour - grey (RAL 7001)
up to 80x106 cJ/kg (up to 80 Mrad) with lenght marking in feet Note
Advantages
Highly-flexible, easy to install
Available on request
with blue cores (DC)
with red cores (AC)
Black or TPE outer sheath

Application
HELUKABEL TRAYCONTROL 500-C is a flexible, screened and oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER
allows this cable to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 edition 2012. Approved for open,
unprotected installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life for industrial applications
in dry, damp and wet environments. Recommended applications: production lines, bottling plants, machine construction, switch cabinets, conveyor
systems, packaging machines, automotive industry.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62813 0,507 2 x 20 7,0 35,0 95,0 62841 1,31 20 x 16 17,5 340,0 524,0
62814 0,507 3 x 20 7,6 42,0 115,0 62842 1,31 25 x 16 19,6 434,0 704,0
62815 0,507 7 x 20 9,4 69,0 164,0 62843 2,08 3 x 14 9,8 112,0 179,0
62816 0,507 12 x 20 11,0 108,0 266,0 62844 2,08 4 x 14 10,7 121,0 222,0
62817 0,507 25 x 20 16,1 240,0 435,0 62845 2,08 5 x 14 11,6 150,0 266,0
62818 0,963 2 x 18 8,1 50,0 110,0 62846 2,08 7 x 14 12,5 200,0 326,0
62819 0,963 3 x 18 8,2 60,0 118,0 62847 2,08 9 x 14 15,0 240,0 435,0
62820 0,963 4 x 18 8,8 71,0 136,0 62848 2,08 10 x 14 16,3 264,0 427,0
62821 0,963 5 x 18 9,4 88,0 148,0 62849 2,08 12 x 14 16,9 350,0 592,0
62822 0,963 7 x 18 10,1 111,0 192,0 62850 2,08 15 x 14 18,3 409,0 635,0
62823 0,963 9 x 18 11,4 140,0 244,0 62851 2,08 18 x 14 19,5 471,0 780,0
62824 0,963 10 x 18 12,0 150,0 283,0 62852 2,08 19 x 14 19,7 505,0 799,0
62825 0,963 12 x 18 12,9 184,0 329,0 62853 2,08 25 x 14 23,3 652,0 1042,0
62826 0,963 15 x 18 14,8 207,0 377,0 62854 3,31 3 x 12 11,4 137,0 237,0
62827 0,963 18 x 18 15,7 260,0 435,0 62855 3,31 4 x 12 12,2 169,0 314,0
62828 0,963 19 x 18 15,7 280,0 443,0 62856 3,31 5 x 12 13,4 201,0 386,0
62829 0,963 25 x 18 17,7 349,0 571,0 62857 3,31 6 x 12 14,6 236,0 425,0
62830 1,31 3 x 16 8,9 74,0 144,0 62858 3,31 7 x 12 15,5 262,0 496,0
62831 1,31 4 x 16 9,6 90,0 172,0 62859 3,31 9 x 12 17,7 334,0 740,0
62832 1,31 5 x 16 10,3 104,0 188,0 62860 3,31 12 x 12 19,7 434,0 887,0
62833 1,31 6 x 16 10,5 120,0 203,0 62861 3,31 15 x 12 21,0 531,0 903,0
62834 1,31 7 x 16 11,3 134,0 244,0 62862 3,31 19 x 12 23,1 720,0 1123,0
62835 1,31 9 x 16 12,6 165,0 308,0 62863 3,31 20 x 12 25,0 764,0 1490,0
62836 1,31 10 x 16 12,9 180,0 346,0 62864 3,31 25 x 12 27,1 914,0 1865,0
62837 1,31 12 x 16 15,1 244,0 423,0 62865 5,26 3 x 10 14,1 240,0 389,0
62838 1,31 15 x 16 16,4 270,0 441,0 62866 5,26 4 x 10 15,5 305,0 549,0
62839 1,31 18 x 16 17,3 319,0 512,0 62867 5,26 5 x 10 16,8 399,0 610,0
62840 1,31 19 x 16 17,6 327,0 503,0 62868 5,26 7 x 10 18,2 505,0 851,0

Continuation

376
Cables according to international Approvals / PVC-Control Cables UL/CSA

TRAYCONTROL 500-C flexible, oil-resistant, screened,


EMC-preferred type, open installation TC-ER, PLTC-ER, ITC-ER, NFPA 79 Edition 2012
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62869 5,26 9 x 10 20,9 704,0 1132,0 62873 13,3 4 x 6 23,3 740,0 1202,0
62870 5,26 12 x 10 24,4 940,0 1523,0 62874 21,2 4 x 4 28,6 1140,0 1971,0
62871 5,26 19 x 10 27,5 1210,0 1952,0 62875 33,6 4 x 2 33,2 1576,0 2887,0
62872 8,37 4 x 8 19,9 535,0 852,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

377
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-600-Y-CY UL/CSA flexible, number coded, 1000 V, EMC-preferred


type, meter marking

Technical data Cable structure Properties


Special PVC control cables Bare copper, fine wire conductors, Extensively oil resistant, oil-/ chemical
adapted to DIN VDE 0276 part 627, acc. to DIN VDE 0295 cl.5, BS 6360 Resistance - see table Technical
DIN VDE 0285-525-2-51/ cl.5 and IEC 60228 cl.5 Informations
DIN EN 50525-2-51, with insulation Core insulation of special PVC UV-resistant (building with black sheath)
thickness for 1 kV type and compound type TI2 to The materials used in manufacture are
UL-Std.758 Style 21179 DIN VDE 0207-363-3 / DIN EN 50363-3 cadmium-free and contain no silicone
Temperature range and class 43 acc. to UL-Std.1581 and free from substances harmful to
flexing -5C to +80C Core identification to DIN VDE 0293 the wetting properties of lacquers
fixed installation -40C to +80C black cores with continuous white Tests
Nominal voltage numbering PVC self-extinguishing and flame retardant
VDE U0/U 600/1000 V GN-YE conductor, 3 cores and above acc. to DIN VDE 0482-332-1-2,
UL/CSA 1000 V in the outer layer DIN EN 60332-1-2, IEC 60332-1 (equivalent
Test voltage 4000 V Cores stranded in layers with DIN VDE 0472 part 804
Breakdown voltage min. 8000 V optimal lay-length test method B), UL VW-1, CSA FT1
Insulation resistance PVC-insulated inner sheath TM2, to
min. 20 MOhm x km DIN VDE 0207-363-4-1/DIN EN 50363-4-1, Note
Minimum bending radius class 43 acc. to UL-Std.1581 G = with green-yellow conductor
flexing 10x cable Braided screen of tinned Cu wires, x = without green-yellow conductor (OZ)
fixed installation 5x cable coverage approx. 85% AWG sizes are approximate equivalent
Radiation resistance Outer sheath of special PVC values. The actual cross-section is in mm.
up to 80x106 cJ/kg (up to 80 Mrad) compound type TM2 to unscreened analogue type:
Coupling resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1 JZ-600 UL/CSA, confer page 362
max. 250 Ohm/km and class 43 acc. to UL-Std.1581
Sheath colour black (RAL 9005) or grey
(RAL 7001)
with meter marking

Application
PVC control cable for measuring, monitoring and control purposes in tool machinery, conveyor belts and production lines in machinery, in air
conditioning, in foundries and steel mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile
stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be used
as direct burrial- or as underwater cable. Interference-free transmission of signals and pulses is assured by the high degree of screening.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
12345 2 x 0,5 20 8,3 41,0 129,0 12410 2 x 0,5 20 8,3 41,0 129,0
12346 3 G 0,5 20 8,6 45,0 150,0 12411 3 G 0,5 20 8,6 45,0 150,0
12347 4 G 0,5 20 9,4 54,0 170,0 12412 4 G 0,5 20 9,4 54,0 170,0
12348 5 G 0,5 20 10,1 66,0 199,0 12413 5 G 0,5 20 10,1 66,0 199,0
12349 7 G 0,5 20 12,1 79,0 235,0 12414 7 G 0,5 20 12,1 79,0 235,0
12350 12 G 0,5 20 14,7 137,0 320,0 12415 12 G 0,5 20 14,7 137,0 320,0
12351 18 G 0,5 20 17,3 156,0 428,0 12416 18 G 0,5 20 17,3 156,0 428,0
12352 25 G 0,5 20 20,6 250,0 503,0 12417 25 G 0,5 20 20,6 250,0 503,0
12353 2 x 0,75 19 8,7 46,0 143,0 12418 2 x 0,75 19 8,7 46,0 143,0
12354 3 G 0,75 19 9,0 57,0 155,0 12419 3 G 0,75 19 9,0 57,0 155,0
12355 4 G 0,75 19 9,9 63,0 190,0 12420 4 G 0,75 19 9,9 63,0 190,0
12356 5 G 0,75 19 10,8 76,0 228,0 12421 5 G 0,75 19 10,8 76,0 228,0
12357 7 G 0,75 19 13,0 100,0 323,0 12422 7 G 0,75 19 13,0 100,0 323,0
12358 12 G 0,75 19 15,8 175,0 410,0 12423 12 G 0,75 19 15,8 175,0 410,0
12359 18 G 0,75 19 17,9 240,0 560,0 12424 18 G 0,75 19 17,9 240,0 560,0
12360 25 G 0,75 19 22,8 306,0 730,0 12425 25 G 0,75 19 22,8 306,0 730,0
12361 2x1 18 9,4 54,0 150,0 12426 2x1 18 9,4 54,0 150,0
12362 3G1 18 9,8 64,0 163,0 12427 3G1 18 9,8 64,0 163,0
12363 4G1 18 10,8 76,0 200,0 12428 4G1 18 10,8 76,0 200,0
12364 5G1 18 12,1 89,0 239,0 12429 5G1 18 12,1 89,0 239,0
12365 7G1 18 14,5 114,0 289,0 12430 7G1 18 14,5 114,0 289,0
12366 12 G 1 18 17,4 186,0 464,0 12431 12 G 1 18 17,4 186,0 464,0
12367 18 G 1 18 20,7 284,0 628,0 12432 18 G 1 18 20,7 284,0 628,0
12368 25 G 1 18 24,8 387,0 855,0 12433 25 G 1 18 24,8 387,0 855,0
12369 2 x 1,5 16 10,2 64,0 162,0 12434 2 x 1,5 16 10,2 64,0 162,0
12370 3 G 1,5 16 10,9 82,0 187,0 12435 3 G 1,5 16 10,9 82,0 187,0
12371 4 G 1,5 16 12,2 99,0 240,0 12436 4 G 1,5 16 12,2 99,0 240,0

Continuation

378
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-600-Y-CY UL/CSA flexible, number coded, 1000 V, EMC-preferred


type, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
12372 5 G 1,5 16 13,3 123,0 289,0 12437 5 G 1,5 16 13,3 123,0 289,0
12373 7 G 1,5 16 16,0 148,0 383,0 12438 7 G 1,5 16 16,0 148,0 383,0
12374 12 G 1,5 16 19,6 274,0 592,0 12439 12 G 1,5 16 19,6 274,0 592,0
12375 18 G 1,5 16 23,4 386,0 806,0 12440 18 G 1,5 16 23,4 386,0 806,0
12376 25 G 1,5 16 28,2 531,0 1241,0 12441 25 G 1,5 16 28,2 531,0 1241,0
12377 2 x 2,5 14 11,5 110,0 272,0 12442 2 x 2,5 14 11,5 110,0 272,0
12378 3 G 2,5 14 12,2 148,0 298,0 12443 3 G 2,5 14 12,2 148,0 298,0
12379 4 G 2,5 14 13,4 169,0 345,0 12444 4 G 2,5 14 13,4 169,0 345,0
12380 5 G 2,5 14 14,9 220,0 427,0 12445 5 G 2,5 14 14,9 220,0 427,0
12381 7 G 2,5 14 17,9 284,0 561,0 12446 7 G 2,5 14 17,9 284,0 561,0
12382 12 G 2,5 14 21,9 470,0 857,0 12447 12 G 2,5 14 21,9 470,0 857,0
12383 18 G 2,5 14 26,1 572,0 1355,0 12448 18 G 2,5 14 26,1 572,0 1355,0
12384 25 G 2,5 14 31,9 740,0 1995,0 12449 25 G 2,5 14 31,9 740,0 1995,0
12385 2x4 12 14,3 124,0 306,0 12450 2x4 12 14,3 124,0 306,0
12386 3G4 12 15,1 178,0 391,0 12451 3G4 12 15,1 178,0 391,0
12387 4G4 12 16,7 234,0 527,0 12452 4G4 12 16,7 234,0 527,0
12388 5G4 12 18,6 284,0 700,0 12453 5G4 12 18,6 284,0 700,0
12389 7G4 12 20,0 321,0 920,0 12454 7G4 12 20,0 321,0 920,0
12390 3G6 10 17,0 245,0 629,0 12455 3G6 10 17,0 245,0 629,0
12391 4G6 10 18,7 316,0 731,0 12456 4G6 10 18,7 316,0 731,0
12392 5G6 10 20,7 442,0 1105,0 12457 5G6 10 20,7 442,0 1105,0
12393 7G6 10 23,0 530,0 1465,0 12458 7G6 10 23,0 530,0 1465,0
12394 3 G 10 8 19,6 367,0 1125,0 12459 3 G 10 8 19,6 367,0 1125,0
12395 4 G 10 8 21,9 549,0 1345,0 12460 4 G 10 8 21,9 549,0 1345,0
12396 5 G 10 8 24,1 604,0 1635,0 12461 5 G 10 8 24,1 604,0 1635,0
12397 7 G 10 8 26,8 820,0 2210,0 12462 7 G 10 8 26,8 820,0 2210,0
12398 3 G 16 6 23,5 653,0 1395,0 12463 3 G 16 6 23,5 653,0 1395,0
12399 4 G 16 6 26,4 807,0 1870,0 12464 4 G 16 6 26,4 807,0 1870,0
12400 5 G 16 6 28,8 940,0 2720,0 12465 5 G 16 6 28,8 940,0 2720,0
12401 7 G 16 6 31,9 1345,0 3213,0 12466 7 G 16 6 31,9 1345,0 3213,0
12402 3 G 25 4 28,0 920,0 2465,0 12467 3 G 25 4 28,0 920,0 2465,0
12403 4 G 25 4 32,5 1169,0 2750,0 12468 4 G 25 4 32,5 1169,0 2750,0
12404 5 G 25 4 35,7 1420,0 3490,0 12469 5 G 25 4 35,7 1420,0 3490,0
12405 7 G 25 4 39,0 1921,0 4980,0 12470 7 G 25 4 39,0 1921,0 4980,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

379
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-604-FCY TC TRAY CABLE PVC power cable, exposed


run, screened, NFPA 79 Edition 2012, 90C, 600 V, EMC-preferred type, meter marking

Technical data Cable structure Properties


PVC power cable, screened to Bare copper, fine wire conductors, self-extinguishing and flame retardant
UL-Std.1277 TRAY CABLE acc. to DIN VDE 0295 cl.5, BS 6360 acc. to CSA FT4
Multinorm cl.5 and IEC 60228 cl.5 The materials used in manufacture are
AWM-Style 2587 to UL-Std.758 and Core insulation of special PVC class 12 B cadmium-free and contain no silicone
CSA C22.2 No 210 I/II A/B 90C 600 V to tab.50.155 acc. to UL-Std.1581, and free from substances harmful to
Temperature range type TFF acc. to UL-Std. 62 the wetting properties of lacquers
dry environment (AWG 20-AWG 16), uv-resistant
flexing -5C to +90C type THHW acc. to UL-Std.83 (AWG 14)
fixed installation -25C to +90C Core identification to DIN VDE 0293 Note
wet environment black cores with continuous white G = with green-yellow conductor
flexing -5C to +75C numbering x = without green-yellow conductor (OZ)
fixed installation -25C to +75C GN-YE conductor, 3 cores and above AWG sizes are approximate equivalent
Nominal voltage UL 600 V in the outer layer values. The actual cross-section is in mm.
Test voltage 3000 V Cores stranded in layers with optimal unscreened analogue type:
Breakdown voltage min. 6000 V lay-length JZ-604 TC TRAY CABLE, confer page 364
Insulation resistance Special separation foil
min. 20 MOhm x km Tinned copper braided screening, approx.
Minimum bending radius 85% coverage
10x cable Outer sheath of special PVC
Radiation resistance acc. to UL-Std.1277 tab.11.2
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour black (RAL 9005)
Coupling resistance with meter marking
max. 250 Ohm/km

Application
USA NFPA 79 edition 2012 conformant flexible power cables up to 600 V, for all machinery in tool and plant constuction, suitable for installation in
dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation from the cable rack
to machines and industrial plants.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
69750 2x1 18 8,6 50,0 151,0 69780 4 G 2,5 14 11,4 148,0 341,0
69751 3G1 18 9,0 60,0 164,0 69781 5 G 2,5 14 12,4 181,0 420,0
69752 4G1 18 9,7 71,0 200,0 69782 7 G 2,5 14 15,3 255,0 551,0
69753 5G1 18 10,5 88,0 229,0 69783 8 G 2,5 14 16,5 285,0 583,0
69754 7G1 18 12,2 111,0 306,0 69784 9 G 2,5 14 16,5 309,0 593,0
69755 9G1 18 13,2 139,0 371,0 69785 10 G 2,5 14 17,9 340,0 631,0
69756 10 G 1 18 15,0 150,0 411,0 69786 12 G 2,5 14 18,4 441,0 847,0
69757 12 G 1 18 15,4 184,0 460,0 69787 18 G 2,5 14 22,4 570,0 1336,0
69758 18 G 1 18 17,8 260,0 624,0 69788 25 G 2,5 14 26,5 738,0 1921,0
69759 25 G 1 18 21,9 349,0 845,0 69789 3G4 12 11,6 174,0 381,0
69760 34 G 1 18 24,5 486,0 984,0 69790 4G4 12 12,6 230,0 504,0
69761 50 G 1 18 26,2 625,0 1096,0 69791 5G4 12 14,5 273,0 692,0
69762 2 x 1,5 16 9,0 63,0 161,0 69792 7G4 12 17,1 316,0 908,0
69763 3 G 1,5 16 9,4 80,0 181,0 69793 9G4 12 18,4 402,0 1104,0
69764 4 G 1,5 16 10,2 97,0 240,0 69794 12 G 4 12 20,5 507,0 1497,0
69765 5 G 1,5 16 11,1 119,0 274,0 69795 18 G 4 12 25,0 751,0 2104,0
69766 7 G 1,5 16 12,9 147,0 367,0 69796 3G6 10 13,8 240,0 623,0
69767 8 G 1,5 16 14,5 170,0 431,0 69797 4G6 10 15,1 305,0 729,0
69768 9 G 1,5 16 14,5 182,0 437,0 69798 5G6 10 16,4 439,0 1082,0
69769 10 G 1,5 16 15,8 193,0 511,0 69799 7G6 10 18,0 505,0 1414,0
69770 12 G 1,5 16 16,2 267,0 598,0 69800 3 G 10 8 17,6 350,0 1108,0
69771 16 G 1,5 16 17,9 315,0 630,0 69801 4 G 10 8 19,3 535,0 1324,0
69772 18 G 1,5 16 18,9 374,0 787,0 69802 5 G 10 8 22,1 592,0 1596,0
69773 25 G 1,5 16 22,3 526,0 1240,0 69803 7 G 10 8 24,2 810,0 2186,0
69774 34 G 1,5 16 24,9 629,0 1401,0
69775 41 G 1,5 16 26,7 801,0 2671,0
69776 50 G 1,5 16 33,7 885,0 3614,0
69777 61 G 1,5 16 36,0 1100,0 4089,0
69778 2 x 2,5 14 10,0 96,0 269,0
69779 3 G 2,5 14 10,5 144,0 294,0

Dimensions and specifications may be changed without prior notice. (RN01)

380
Cables according to international Approvals / PVC-Control Cables UL/CSA

JZ-604-YCY TC TRAY CABLE PVC power cable, exposed


run, screened, NFPA 79 Edition 2012, 90C, 600 V, EMC-preferred type, meter marking

Technical data Cable structure Properties


PVC power cable, screened to Bare copper, fine wire conductors, acc. to self-extinguishing and flame retardant
UL-Std.1277 TRAY CABLE DIN VDE 0295 cl.5, BS 6360 cl.5 and acc. to CSA FT4
Multinorm IEC 60228 cl.5 The materials used in manufacture are
also conforms to the following standards: Core insulation of special PVC class 12 B cadmium-free and contain no silicone
AWM-Style 2587 to UL-Std.758 (cUL) to tab.50.155 acc. to UL-Std.1581 and free from substances harmful to
and CSA type TC FT4 to C22.2 no 230, CSA type TFF acc. to UL-Std.62 (AWG 20-AWG the wetting properties of lacquers
C22.2 No 210 I/II A/B 90C 600 V FT4 16) uv-resistant
Temperature range type THHW to UL-Std.83 (AWG 14)
dry environment Core identification to DIN VDE 0293 Note
flexing -5C to +90C black cores with continuous white G = with green-yellow conductor
fixed installation -25C to +90C numbering x = without green-yellow conductor (OZ)
wet environment GN-YE conductor, 3 cores and above AWG sizes are approximate equivalent
flexing -5C to +75C in the outer layer values. The actual cross-section is in mm.
fixed installation -25C to +75C Cores stranded in layers with optimal unscreened analogue type:
Nominal voltage UL 600 V lay-length JZ 604 TC TRAY CABLE, confer page 364
Test voltage 3000 V PVC-inner sheath acc. to UL-Std.1277
Breakdown voltage min. 6000 V tab.11.2
Insulation resistance Tinned copper braided screening,
min. 20 MOhm x km approx. 85% coverage
Minimum bending radius Outer sheath of special PVC
10x cable acc. to UL-Std.1277 tab.11.2,
Radiation resistance Sheath colour black (RAL 9005)
up to 80x106 cJ/kg (up to 80 Mrad) with meter marking
Coupling resistance
max. 250 Ohm/km

Application
USA NFPA 79 edition 2012 conformant flexible power cables up to 600 V, for all machinery in tool and plant constuction, suitable for installation in
dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation from the cable rack
to machines and industrial plants. N
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
69804 3 G 16 6 25,2 653,0 1385,0 69822 4 G 95 3/0 55,0 4060,0 10200,0
69805 4 G 16 6 27,8 807,0 1861,0 69823 5 G 95 3/0 60,5 5244,0 13800,0
69806 5 G 16 6 31,2 940,0 2614,0 69824 3 G 120 4/0 54,0 4176,0 11090,0
69807 7 G 16 6 34,5 1345,0 3211,0 69825 4 G 120 4/0 59,5 5231,0 13620,0
69808 3 G 25 4 29,0 920,0 2455,0 69826 5 G 120 4/0 64,5 6624,0 15420,0
69809 4 G 25 4 32,4 1169,0 2721,0
69810 5 G 25 4 34,2 1420,0 3490,0
69811 7 G 25 4 40,3 1921,0 4960,0
69812 3 G 35 2 32,4 1250,0 3130,0
69813 4 G 35 2 36,2 1680,0 4100,0
69814 5 G 35 2 40,5 2020,0 4921,0
69815 3 G 50 1 40,4 1887,0 4560,0
69816 4 G 50 1 45,5 2370,0 5761,0
69817 5 G 50 1 50,0 2880,0 7186,0
69818 3 G 70 2/0 47,1 2516,0 5580,0
69819 4 G 70 2/0 51,1 3257,0 7387,0
69820 5 G 70 2/0 56,0 4032,0 9290,0
69821 3 G 95 3/0 50,1 3086,0 8520,0

Dimensions and specifications may be changed without prior notice. (RN01)

381
Cables according to international Approvals / PVC-Control Cables UL/CSA

TRAYCONTROL 600-C flexible, oil-resistant, screened,


EMC-preferred type, open installation (TC-ER), NFPA 79 Edition 2012

Technical data Cable structure Properties


PVC power cable acc. to UL-Std.1277 Bare copper conductor, fine wire with self-extinguishing and flame retardant
and UL-Std.2277 AWG dimensions acc. to CSA FT4
Temperature range Core insulation of special PVC The materials used in manufacture are
UL+CSA TC -40C to +90C with transparent nylon skin cadmium-free and contain no silicone
AWM -40C to +90C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage black cores with continuous white the wetting properties of lacquers
TC 600 V numbering UV-resistant
AWM 1000 V GN-YE conductor, 3 cores and above Tests
WTTC 1000 V in the outer layer UL:
Test voltage 3000 V Cores stranded in layers with TC-ER, PLTC-ER (AWG 18 - AWG 12),
Coupling resistance optimal lay-lengths ITC-ER (AWG 18 - AWG 12),
max. 250 Ohm/km Separating foil UL Type WTTC, UL Type MTW
Minimum bending radius Braided screening of tinned copper wires, NFPA 79 2012, Oil Res I (Oil Res II also
6x cable coverage approx. 85% available), 90C dry / 75C wet,
Insulation resistance Separator Class 1 Div. 2 per NEC Art. 336, 392, 501
min. 20 MOhm x km Outer sheath of special PVC CSA:
Radiation resistance Sheath colour - black (RAL 9005) c (UL) CIC-TC FT4,
up to 80x106 cJ/kg (up to 80 Mrad) with lenght marking in feet CSA AWM I/II A/B FT4

Note
Advantages
TC-ER, Tray Cable Exposed Run
Simple installation
Outstanding flexibility

Application
USA NFPA 79 edition 2012 compliant, screened, flexible power cable to 600 V (WTTC 1000 V), for all tool and plant construction machinery, suitable
for installation in dry, damp and wet environments, outdoors and in pipes. For underground installation and for open, unprotected installtion from
the cable tray to the machine and industrial plants.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
63049 0,963 3 x 18 8,2 31,0 118,0 63064 2,08 5 x 14 11,6 139,0 264,0
63050 0,963 4 x 18 8,8 52,0 136,0 63065 2,08 7 x 14 12,5 185,0 325,0
63051 0,963 5 x 18 9,4 62,0 149,0 63066 2,08 12 x 14 16,9 309,0 591,0
63052 0,963 7 x 18 10,1 83,0 193,0 63067 2,08 18 x 14 19,5 448,0 780,0
63053 0,963 12 x 18 12,9 143,0 328,0 63068 2,08 25 x 14 23,3 632,0 1041,0
63054 0,963 18 x 18 15,7 207,0 431,0 63069 3,31 4 x 12 12,2 179,0 313,0
63055 0,963 25 x 18 17,7 284,0 569,0 63070 3,31 5 x 12 13,4 223,0 384,0
62997 1,31 3 x 16 8,9 57,0 144,0 63071 3,31 7 x 12 15,5 298,0 492,0
63056 1,31 4 x 16 9,6 72,0 172,0 63072 5,26 4 x 10 15,5 256,0 547,0
63057 1,31 5 x 16 10,3 84,0 186,0 63073 5,26 5 x 10 16,8 312,0 608,0
63058 1,31 7 x 16 11,3 124,0 243,0 63074 5,26 7 x 10 18,2 430,0 850,0
63059 1,31 12 x 16 15,1 199,0 421,0 63075 8,37 4 x 8 19,9 426,0 851,0
63060 1,31 18 x 16 17,3 290,0 510,0 63076 13,3 4 x 6 23,3 657,0 1197,0
63061 1,31 25 x 16 19,6 384,0 704,0 63077 21,2 4 x 4 28,6 1026,0 1970,0
63062 2,08 3 x 14 9,8 85,0 178,0 63078 33,6 4 x 2 33,2 1412,0 2874,0
63063 2,08 4 x 14 10,7 115,0 220,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

382
UL/CSA PUR/TPE CONTROL CABLES
Cables according to international Approvals / PUR-Control Cables UL/CSA

JZ-602-PUR 80C, 600 V, two approval control cable, meter marking

Technical data Cable structure Properties


Control cable of special-PUR to UL CSA Bare copper, fine wire stranded to Resistant to mineral oils, synthetic oils,
AWM I/II A/B Style 20939 (sheath insulation) DIN VDE 0295 cl.5, BS 6360 cl.5 and coolant, UV-radiation,
and CSA IEC 60228 cl.5 oxygene, ozon and hydrolysis. Conditionally
Temperature range Core insulation of PVC resistant to microbes.
flexing -5C to +80C compound type TI3 to The materials used in manufacture are
fixed installation -40C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 cadmium-free and contain no silicone
Nominal voltage and UL-Style 10012 and free from substances harmful to
UL/CSA 600 V Core identification to DIN VDE 0293 the wetting properties of lacquers
Test voltage 3000 V black cores with continuous white
Breakdown voltage min. 6000 V numbering Note
Insulation resistance GN-YE conductor, 3 cores and above G = with green-yellow conductor
min 20 MOhm x km in the outer layer x = without green-yellow conductor (OZ)
Minimum bending radius Cores stranded in layers with AWG sizes are approximate equivalent
flexing 7,5x cable optimal lay-length values. The actual cross-section is in mm.
fixed installation 4x cable Outer sheath of special full-polyurethane unscreened analogue type:
Radiation resistance Sheath colour grey (RAL 7001) JZ-602-C-PUR, confer page 389
up to 100x106 cJ/kg (up to 100 Mrad) with meter marking

Application
UL and CSA approved flexible control cable rated at 600 V, primarily designed for exporters to the US or Canadian market. Used in machine tools,
control systems, connection between control panels and machines, assembly lines and other industrial equipment. Suitable for installation in dry,
moist, wet and outdoor environment and moderate flexing applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12471 2 x 0,5 20 5,8 9,6 52,0 12495 2 x 1,5 16 6,8 28,8 75,0
12472 3 G 0,5 20 6,2 14,0 64,0 12496 3 G 1,5 16 7,4 44,0 96,0
12473 4 G 0,5 20 6,6 19,0 72,0 12497 4 G 1,5 16 8,0 58,0 117,0
12474 5 G 0,5 20 7,2 24,0 88,0 12498 5 G 1,5 16 8,6 72,0 140,0
12475 7 G 0,5 20 8,4 34,0 130,0 12499 7 G 1,5 16 10,5 101,0 186,0
12476 8 G 0,5 20 9,5 38,4 145,0 12500 9 G 1,5 16 12,7 129,7 244,0
12477 9 G 0,5 20 10,3 43,2 180,0 12501 12 G 1,5 16 13,3 173,0 319,0
12478 12 G 0,5 20 10,8 58,0 196,0 12502 18 G 1,5 16 15,7 260,0 451,0
12479 18 G 0,5 20 12,8 86,0 260,0 12503 25 G 1,5 16 18,8 360,0 625,0
12480 25 G 0,5 20 15,4 120,0 368,0 12504 34 G 1,5 16 22,0 490,0 850,0
12481 34 G 0,5 20 17,6 163,0 502,0 12505 41 G 1,5 16 23,6 590,0 1041,0
12482 41 G 0,5 20 19,7 197,0 594,0 12506 2 x 2,5 14 8,1 48,0 115,0
12483 2x1 18 6,2 19,2 57,0 12507 3 G 2,5 14 8,6 72,0 143,0
12484 3G1 18 6,6 27,0 68,0 12508 4 G 2,5 14 10,0 96,0 185,0
12485 4G1 18 7,2 38,4 79,0 12509 5 G 2,5 14 10,8 120,0 221,0
12486 5G1 18 7,8 48,0 97,0 12510 7 G 2,5 14 13,0 168,0 293,0
12487 7G1 18 9,1 67,0 141,0 12511 9 G 2,5 14 15,5 216,0 429,0
12488 8G1 18 9,9 76,8 152,0 12512 12 G 2,5 14 16,6 288,0 563,0
12489 9G1 18 11,0 86,4 190,0 12513 18 G 2,5 14 19,5 432,0 854,0
12490 12 G 1 18 11,7 115,2 211,0 12514 19 G 2,5 14 19,5 456,0 914,0
12491 18 G 1 18 14,0 173,0 284,0 12515 25 G 2,5 14 23,8 600,0 1188,0
12492 25 G 1 18 17,0 240,0 394,0 12516 3G4 12 11,1 115,0 232,0
12493 34 G 1 18 19,2 326,0 521,0 12517 4G4 12 12,4 154,0 298,0
12494 41 G 1 18 21,0 394,0 609,0

Continuation

384
Cables according to international Approvals / PUR-Control Cables UL/CSA

JZ-602-PUR 80C, 600 V, two approval control cable, meter marking


Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12518 5G4 12 13,7 192,0 358,0 12530 4 G 16 6 23,0 615,0 1045,0
12519 7G4 12 16,2 269,0 460,0 12531 5 G 16 6 25,5 768,0 1260,0
12520 3G6 10 12,8 173,0 360,0 12532 7 G 16 6 28,2 1075,0 1760,0
12521 4G6 10 14,1 231,0 402,0 12533 3 G 25 4 25,0 720,0 1180,0
12522 5G6 10 15,7 288,0 484,0 12534 4 G 25 4 28,1 960,0 1507,0
12523 7G6 10 19,2 403,0 630,0 12535 5 G 25 4 30,9 1200,0 1858,0
12524 3 G 10 8 16,8 288,0 535,0 12536 7 G 25 4 35,5 1680,0 2830,0
12525 4 G 10 8 18,3 384,0 653,0 12537 3 G 35 2 28,6 1008,0 1590,0
12526 5 G 10 8 20,1 480,0 786,0 12538 4 G 35 2 31,7 1344,0 2123,0
12527 7 G 10 8 22,4 672,0 1100,0 12539 5 G 35 2 35,5 1680,0 2612,0
12528 2 x 16 6 19,2 307,0 640,0 12540 4 G 50 1 35,8 1920,0 3058,0
12529 3 G 16 6 20,5 461,0 810,0 12541 4 G 70 2/0 41,6 2688,0 4254,0
12542 4 G 95 3/0 46,0 3648,0 5762,0
12543 4 G 120 4/0 52,8 4608,0 7280,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS
Cable Gland - HELUTOP HT-MS-EP 4

385
Cables according to international Approvals / PUR-Control Cables UL/CSA

JZ-602-PUR DC/AC 80C, 600 V, two approval control cable, meter


marking

Technical data Cable structure Properties


Control cable of special-PUR to Bare copper, fine wire stranded to Resistant to mineral oils, synthetic oils,
UL CSA AWM I/II A/B Style 20939 DIN VDE 0295 cl.5, BS 6360 cl.5 and coolant, UV-radiation,
(sheath insulation) and CSA IEC 60228 cl.5 oxygene, ozon and hydrolysis.
Temperature range Core insulation of PVC Conditionally resistant to microbes.
flexing -5C to +80C compound type TI3 to High abrasion resistance
fixed installation -40C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 Tear and cut resistant
Nominal voltage UL/CSA 600 V and UL-Style 10012 The materials used in manufacture are
Test voltage 3000 V Core identification blue (DC) or red (AC) with cadmium-free and contain no silicone
Breakdown voltage min. 6000 V continuous white numbering and free from substances harmful to
Insulation resistance GN-YE conductor the wetting properties of lacquers
min 20 MOhm x km Cores stranded in layers with optimal
Minimum bending radius lay-length Note
flexing 7,5x cable Outer sheath of special full-polyurethane G = with green-yellow conductor
fixed installation 4x cable Sheath colour grey (RAL 7001) DC = blue cores;
Radiation resistance with meter marking AC = red cores;
up to 100x106 cJ/kg (up to 100 Mrad) AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
For use on conveyor belts, tooling machines, conveyor system, production lines and automotive production plants. Also for medium mechanical stress
in flexible applications with free movement and without tensile stress. UL and CSA approved control cables espacially for U. S. and Canadian markets.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
JZ-602 PUR DC (blue core) JZ-602 PUR AC (red core)
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12805 3G1 18 6,6 27,0 68,0 12826 3G1 18 6,6 27,0 68,0
12806 4G1 18 7,2 38,0 79,0 12827 4G1 18 7,2 38,0 79,0
12807 5G1 18 7,8 48,0 97,0 12828 5G1 18 7,8 48,0 97,0
12808 7G1 18 9,1 67,0 141,0 12829 7G1 18 9,1 67,0 141,0
12809 12 G 1 18 11,7 115,0 211,0 12830 12 G 1 18 11,7 115,0 211,0
12810 18 G 1 18 14,0 173,0 284,0 12831 18 G 1 18 14,0 173,0 284,0
12811 25 G 1 18 17,0 240,0 394,0 12832 25 G 1 18 17,0 240,0 394,0
12812 3 G 1,5 16 7,4 44,0 96,0 12833 3 G 1,5 16 7,4 44,0 96,0
12813 4 G 1,5 16 8,0 58,0 117,0 12834 4 G 1,5 16 8,0 58,0 117,0
12814 5 G 1,5 16 8,6 72,0 140,0 12835 5 G 1,5 16 8,6 72,0 140,0
12815 7 G 1,5 16 10,5 101,0 186,0 12836 7 G 1,5 16 10,5 101,0 186,0
12816 12 G 1,5 16 13,3 173,0 319,0 12837 12 G 1,5 16 13,3 173,0 319,0
12817 18 G 1,5 16 15,7 260,0 451,0 12838 18 G 1,5 16 15,7 260,0 451,0
12818 25 G 1,5 16 18,8 360,0 625,0 12839 25 G 1,5 16 18,8 360,0 625,0
12819 3 G 2,5 14 8,6 72,0 143,0 12840 3 G 2,5 14 8,6 72,0 143,0
12820 4 G 2,5 14 10,0 96,0 185,0 12841 4 G 2,5 14 10,0 96,0 185,0
12821 5 G 2,5 14 10,8 120,0 221,0 12842 5 G 2,5 14 10,8 120,0 221,0
12822 7 G 2,5 14 13,0 168,0 293,0 12843 7 G 2,5 14 13,0 168,0 293,0
12823 12 G 2,5 14 16,6 288,0 563,0 12844 12 G 2,5 14 16,6 288,0 563,0
12824 18 G 2,5 14 19,5 432,0 854,0 12845 18 G 2,5 14 19,5 432,0 854,0
12825 25 G 2,5 14 23,8 600,0 1188,0 12846 25 G 2,5 14 23,8 600,0 1188,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS
Cable Gland - HELUTOP HT-MS-EP 4

386
Cables according to international Approvals / PUR-Control Cables UL/CSA

JZ-600 PUR tear and coolant resistant, 1000 V, meter marking

Technical data Cable structure Properties


Special PUR control cables Adapted to Bare copper, fine wire conductors, as per High abrasion resistance
DIN VDE 0276 part 627, DIN VDE 0295 cl.5, BS 6360 cl.5 and High flexibility
DIN VDE 0285-525-2-51/ IEC 60228 cl.5 Resistant to ultra violet rays
DIN EN 50525-2-51, with insulation Core insulation of special PVC Wear resistant
thickness for 1 kV type compound type TI2 to resistant to mineral oils and coolant
and UL-Std.758 Style 20234 DIN VDE 0207-363-3 / DIN EN 50363-3 emulsions
Temperature range and class 43 acc. to UL-Std.1581 The materials used in manufacture are
flexing -5C to +80C UL-Style 10012 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage black cores with continuous white the wetting properties of lacquers
VDE U0/U 600/1000 V numbering
UL/CSA 1000 V GN-YE conductor, 3 cores and above Note
Test voltage 4000 V in the outer layer G = with green-yellow conductor
Breakdown voltage min. 8000 V Cores stranded in layers with x = without green-yellow conductor
Insulation resistance optimal lay-length AWG sizes are approximate equivalent
min. 20 MOhm x km Outer sheath of special full-polyurethane values. The actual cross-section is in mm.
Minimum bending radius adapted to screened analogue type:
flexing 7,5x cable DIN VDE 0207-363-10-2/ JZ-600-YC-PUR, confer page 390
fixed installation 4x cable DIN EN 50363-10-2,
Radiation resistance flame retardant acc. to UL-Std.758
up to 100x106 cJ/kg (up to 100 Mrad) Sheath colour black (RAL 9005) or grey
(RAL 7001)
with meter marking

Application
Extremely robust, control cable resistant to mineral oils and to coolant emulsions. In tool machinery, conveyor belts and production lines, for plant
installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses
with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside. Interesting for the export-oriented
machinery plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
N
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
28240 2 x 0,5 20 6,9 9,6 60,0 28305 2 x 0,5 20 6,9 9,6 60,0
28241 3 G 0,5 20 7,3 14,4 70,0 28306 3 G 0,5 20 7,3 14,4 70,0
28242 4 G 0,5 20 7,9 19,0 104,0 28307 4 G 0,5 20 7,9 19,0 104,0
28243 5 G 0,5 20 8,5 24,0 120,0 28308 5 G 0,5 20 8,5 24,0 120,0
28244 7 G 0,5 20 9,9 33,6 141,0 28309 7 G 0,5 20 9,9 33,6 141,0
28245 12 G 0,5 20 12,2 58,0 208,0 28310 12 G 0,5 20 12,2 58,0 208,0
28246 18 G 0,5 20 14,4 86,0 289,0 28311 18 G 0,5 20 14,4 86,0 289,0
28247 25 G 0,5 20 17,2 120,0 342,0 28312 25 G 0,5 20 17,2 120,0 342,0
28248 2 x 0,75 19 7,3 14,4 70,0 28313 2 x 0,75 19 7,3 14,4 70,0
28249 3 G 0,75 19 7,7 21,6 78,0 28314 3 G 0,75 19 7,7 21,6 78,0
28250 4 G 0,75 19 8,3 29,0 134,0 28315 4 G 0,75 19 8,3 29,0 134,0
28251 5 G 0,75 19 9,1 36,0 149,0 28316 5 G 0,75 19 9,1 36,0 149,0
28252 7 G 0,75 19 10,7 50,0 201,0 28317 7 G 0,75 19 10,7 50,0 201,0
28253 12 G 0,75 19 13,1 86,0 269,0 28318 12 G 0,75 19 13,1 86,0 269,0
28254 18 G 0,75 19 15,6 130,0 378,0 28319 18 G 0,75 19 15,6 130,0 378,0
28255 25 G 0,75 19 18,9 180,0 498,0 28320 25 G 0,75 19 18,9 180,0 498,0
28256 2x1 18 7,9 19,2 86,0 28321 2x1 18 7,9 19,2 86,0
28257 3G1 18 8,3 29,0 100,0 28322 3G1 18 8,3 29,0 100,0
28258 4G1 18 9,1 38,4 107,0 28323 4G1 18 9,1 38,4 107,0
28259 5G1 18 9,9 48,0 130,0 28324 5G1 18 9,9 48,0 130,0
28260 7G1 18 11,7 67,0 174,0 28325 7G1 18 11,7 67,0 174,0
28261 12 G 1 18 14,5 115,0 290,0 28326 12 G 1 18 14,5 115,0 290,0
28262 18 G 1 18 17,3 173,0 405,0 28327 18 G 1 18 17,3 173,0 405,0
28263 25 G 1 18 21,1 240,0 570,0 28328 25 G 1 18 21,1 240,0 570,0
28264 2 x 1,5 16 8,7 29,0 97,0 28329 2 x 1,5 16 8,7 29,0 97,0
28265 3 G 1,5 16 9,2 43,0 118,0 28330 3 G 1,5 16 9,2 43,0 118,0
28266 4 G 1,5 16 10,0 58,0 141,0 28331 4 G 1,5 16 10,0 58,0 141,0
28267 5 G 1,5 16 11,0 72,0 181,0 28332 5 G 1,5 16 11,0 72,0 181,0
28268 7 G 1,5 16 13,3 101,0 234,0 28333 7 G 1,5 16 13,3 101,0 234,0
28269 12 G 1,5 16 16,6 173,0 370,0 28334 12 G 1,5 16 16,6 173,0 370,0
28270 18 G 1,5 16 19,7 259,0 520,0 28335 18 G 1,5 16 19,7 259,0 520,0
28271 25 G 1,5 16 23,9 360,0 730,0 28336 25 G 1,5 16 23,9 360,0 730,0

Continuation

387
Cables according to international Approvals / PUR-Control Cables UL/CSA

JZ-600 PUR tear and coolant resistant, 1000 V, meter marking


Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
28272 2 x 2,5 14 9,5 48,0 170,0 28337 2 x 2,5 14 9,5 48,0 170,0
28273 3 G 2,5 14 10,0 72,0 181,0 28338 3 G 2,5 14 10,0 72,0 181,0
28274 4 G 2,5 14 11,1 96,0 203,0 28339 4 G 2,5 14 11,1 96,0 203,0
28275 5 G 2,5 14 12,4 120,0 251,0 28340 5 G 2,5 14 12,4 120,0 251,0
28276 7 G 2,5 14 15,0 168,0 330,0 28341 7 G 2,5 14 15,0 168,0 330,0
28277 12 G 2,5 14 18,4 288,0 553,0 28342 12 G 2,5 14 18,4 288,0 553,0
28278 18 G 2,5 14 22,0 432,0 795,0 28343 18 G 2,5 14 22,0 432,0 795,0
28279 25 G 2,5 14 26,9 600,0 1110,0 28344 25 G 2,5 14 26,9 600,0 1110,0
28280 2x4 12 11,4 77,0 190,0 28345 2x4 12 11,4 77,0 190,0
28281 3G4 12 12,3 115,0 235,0 28346 3G4 12 12,3 115,0 235,0
28282 4G4 12 13,8 154,0 310,0 28347 4G4 12 13,8 154,0 310,0
28283 5G4 12 15,3 192,0 410,0 28348 5G4 12 15,3 192,0 410,0
28284 7G4 12 16,8 269,0 540,0 28349 7G4 12 16,8 269,0 540,0
28285 12 G 4 12 22,9 461,0 860,0 28350 12 G 4 12 22,9 461,0 860,0
28286 3G6 10 14,1 173,0 370,0 28351 3G6 10 14,1 173,0 370,0
28287 4G6 10 15,6 230,0 430,0 28352 4G6 10 15,6 230,0 430,0
28288 5G6 10 17,3 288,0 650,0 28353 5G6 10 17,3 288,0 650,0
28289 7G6 10 19,3 403,0 860,0 28354 7G6 10 19,3 403,0 860,0
28290 3 G 10 8 16,5 288,0 660,0 28355 3 G 10 8 16,5 288,0 660,0
28291 4 G 10 8 18,4 384,0 790,0 28356 4 G 10 8 18,4 384,0 790,0
28292 5 G 10 8 20,5 480,0 960,0 28357 5 G 10 8 20,5 480,0 960,0
28293 7 G 10 8 22,5 672,0 1300,0 28358 7 G 10 8 22,5 672,0 1300,0
28294 3 G 16 6 19,6 461,0 709,0 28359 3 G 16 6 19,6 461,0 709,0
28295 4 G 16 6 21,7 614,0 1114,0 28360 4 G 16 6 21,7 614,0 1114,0
28296 5 G 16 6 24,2 768,0 1620,0 28361 5 G 16 6 24,2 768,0 1620,0
28297 7 G 16 6 25,7 1075,0 1900,0 28362 7 G 16 6 25,8 1075,0 1900,0
28298 3 G 25 4 24,0 720,0 1450,0 28363 3 G 25 4 24,0 720,0 1450,0
28299 4 G 25 4 26,9 960,0 1600,0 28364 4 G 25 4 26,9 960,0 1600,0
28300 5 G 25 4 29,3 1200,0 2050,0 28365 5 G 25 4 29,3 1200,0 2050,0
28301 7 G 25 4 32,6 1680,0 2900,0 28366 7 G 25 4 32,6 1680,0 2900,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-PA
Cable Gland - HELUTOP HT-MS
Cable Gland - HELUTOP HT-MS-EP 4

388
Cables according to international Approvals / PUR-Control Cables UL/CSA

JZ-602-C-PUR screened two approval control cable, 80C, 600 V,


EMC-preferred type, meter marking

Technical data Cable structure Properties


Special PUR-insulated to UL CSA AWM I/II Bare copper, fine wire stranded to Resistant to mineral oils, synthetic oils and
A/B Style 20939 and CSA DIN VDE 0295 cl.5, BS 6360 cl.5 and coolant, UV-radiation, osygene, ozon
Temperature range IEC 60228 cl.5 and hydrolysis. Conditionally resistant to
flexing -5C to +80C Core insulation of special PVC microbes.
fixed installation -40C to +80C compound type TI2 to The materials used in manufacture are
Nominal voltage DIN VDE 0207-363-3 / DIN EN 50363-3 cadmium-free and contain no silicone
UL/CSA 600 V and UL-Style 10012 and free from substances harmful to
Test voltage 3000 V Core identification to DIN VDE 0293 the wetting properties of lacquers
Breakdown voltage min. 6000 V black cores with continuous white
Insulation resistance numbering Note
min. 20 MOhm x km GN-YE conductor, 3 cores and above G = with green-yellow conductor
Minimum bending radius in the outer layer x = without green-yellow conductor (OZ)
flexing 10x cable Cores stranded in layers with AWG sizes are approximate equivalent
fixed installation 5x cable optimal lay-length values. The actual cross-section is in mm.
Radiation resistance PVC-insulated inner sheath YM5 to unscreened analogue type:
up to 100x106 cJ/kg (up to 100 Mrad) DIN VDE 0207-363-4-1/ DIN EN 50363-4-1 JZ-602 PUR, confer page 384
Coupling resistance Braided screen of tinned Cu wires,
max. 250 Ohm/km approx. 85% coverage
Outer sheath of full-polyurethane
Sheath colour grey (RAL 7001)
with meter marking

Application
UL and CSA approved flexible control cables up to 600 V, for all machinery in tooling and plant construction, suitable for installation in dry, moist,
wet and outdoor environments for medium mechanical loads. Designed for the export-orientated machinery manufacturer, specifically for USA and
Canada.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
N
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12550 2 x 0,5 20 7,7 41,0 93,0 12586 5 G 2,5 14 13,2 220,0 329,0
12551 3 G 0,5 20 8,0 45,0 124,0 12587 7 G 2,5 14 15,6 284,0 428,0
12552 4 G 0,5 20 8,6 54,0 133,0 12588 9 G 2,5 14 18,1 349,0 580,0
12553 5 G 0,5 20 9,2 66,0 153,0 12589 12 G 2,5 14 19,2 470,0 761,0
12554 7 G 0,5 20 10,5 79,0 191,0 12590 18 G 2,5 14 23,0 572,0 1140,0
12555 9 G 0,5 20 12,3 94,0 243,0 12591 25 G 2,5 14 28,3 740,0 1551,0
12556 12 G 0,5 20 13,0 137,0 322,0 12592 2x4 12 12,5 124,0 209,0
12557 18 G 0,5 20 15,6 156,0 374,0 12593 3G4 12 13,1 178,0 310,0
12558 25 G 0,5 20 18,2 250,0 436,0 12594 4G4 12 14,5 234,0 456,0
12559 34 G 0,5 20 20,1 316,0 560,0 12595 5G4 12 15,8 284,0 532,0
12560 41 G 0,5 20 22,4 348,0 663,0 12596 7G4 12 19,0 321,0 737,0
12561 2x1 18 8,1 54,0 107,0 12597 2x6 10 14,2 176,0 318,0
12562 3G1 18 8,4 64,0 130,0 12598 3G6 10 15,2 245,0 411,0
12563 4G1 18 9,1 76,0 155,0 12599 4G6 10 16,6 316,0 572,0
12564 5G1 18 10,0 89,0 181,0 12600 5G6 10 18,4 442,0 732,0
12565 7G1 18 11,3 114,0 209,0 12601 7G6 10 22,2 530,0 961,0
12566 9G1 18 13,3 144,0 321,0 12602 3 G 10 8 19,1 367,0 741,0
12567 12 G 1 18 13,8 186,0 341,0 12603 4 G 10 8 21,1 549,0 988,0
12568 18 G 1 18 16,2 284,0 473,0 12604 5 G 10 8 23,7 604,0 1202,0
12569 25 G 1 18 19,5 387,0 650,0 12605 7 G 10 8 26,5 820,0 1743,0
12570 34 G 1 18 22,5 500,0 781,0 12606 3 G 16 6 24,2 653,0 1088,0
12571 41 G 1 18 24,2 578,0 892,0 12607 4 G 16 6 27,2 807,0 1662,0
12572 2 x 1,5 16 8,7 64,0 136,0 12608 5 G 16 6 30,6 940,0 2021,0
12573 3 G 1,5 16 9,2 82,0 165,0 12609 7 G 16 6 33,6 1345,0 2720,0
12574 4 G 1,5 16 10,0 99,0 192,0 12610 3 G 25 4 30,2 920,0 1947,0
12575 5 G 1,5 16 10,8 123,0 224,0 12611 4 G 25 4 33,3 1169,0 2591,0
12576 7 G 1,5 16 12,9 148,0 273,0 12612 5 G 25 4 36,8 1420,0 3197,0
12577 9 G 1,5 16 14,8 187,0 340,0 12613 7 G 25 4 40,6 1921,0 4530,0
12578 12 G 1,5 16 15,6 274,0 461,0 12614 3 G 35 2 33,8 1250,0 2701,0
12579 18 G 1,5 16 18,3 386,0 674,0 12615 4 G 35 2 37,7 1680,0 3277,0
12580 25 G 1,5 16 22,5 531,0 950,0 12616 5 G 35 2 41,5 2020,0 4530,0
12581 34 G 1,5 16 25,1 671,0 1203,0 12617 4 G 50 1 40,5 2370,0 3370,0
12582 41 G 1,5 16 27,3 840,0 1588,0 12618 4 G 70 2/0 46,1 3257,0 4630,0
12583 2 x 2,5 14 10,3 110,0 173,0 12619 4 G 95 3/0 50,7 4060,0 6114,0
12584 3 G 2,5 14 10,8 148,0 220,0 12620 4 G 120 4/0 57,0 5231,0 7417,0
12585 4 G 2,5 14 11,8 169,0 270,0

Dimensions and specifications may be changed without prior notice. (RN01)

389
Cables according to international Approvals / PUR-Control Cables UL/CSA

JZ-600-YC-PUR tear and coolant resistant, 1000 V, Cu-screened,


EMC-preferred type, meter marking

Technical data Cable structure Properties


Special PUR control cables acc. to Bare copper, fine wire conductors, acc. to High abrasion resistance
DIN VDE 0276 part 627, DIN VDE 0295 cl.5, BS 6360 cl.5 and High flexibility
DIN VDE 0285-525-2-51/ IEC 60228 cl.5 Resistant to ultra violet rays
DIN EN 50525-2-51, Core insulation of PVC Wear resistant
with insulation thickness for 1 kV type and compound type TI2 to resistant to mineral oils and coolant
UL-Std.758 Style 20234 DIN VDE 0207-363-3 / DIN EN 50363-3 emulsions
Temperature range and class 43 acc. to UL-Std.1581 The materials used in manufacture are
flexing -5C to +80C UL-Style 10012 cadmium-free and contain no silicone
fixed installation -40C to +80C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage black cores with continuous white the wetting properties of lacquers
VDE U0/U 600/1000 V numbering
UL/CSA 1000 V GN-YE conductor, 3 cores and above Note
Test voltage 4000 V in the outer layer G = with green-yellow conductor
Breakdown voltage min. 8000 V Cores stranded in layers with x = without green-yellow conductor
Insulation resistance optimal lay-length AWG sizes are approximate equivalent
min. 20 MOhm x km Oil resistant PVC inner sheath, TM5 to values. The actual cross-section is in mm.
Minimum bending radius DIN VDE 0207-363-4-1/DIN EN 50363-4-1 unscreened analogue type:
flexing 10x cable and class 43 acc. to UL-Std.1581 JZ-600 PUR, confer page 387
fixed installation 5x cable Tinned copper braided screening,
Radiation resistance approx. 85% coverage
up to 100x106 cJ/kg (up to 100 Mrad) Outer sheath, special full-polyurethane
Coupling resistance compound type TMPU adapted to
max. 250 Ohm/km DIN VDE 0207-363-10-2/
DIN EN 50363-10-2,
flame retardant acc. to UL-Std.758
Sheath colour black (RAL 9005) or grey
(RAL 7001)
with meter marking

Application
Extremely robust sheated cable, used in machinery, tools and plant, in rolling and steel mills at particularly critical poinst. For medium mechanical
stress for flexible use with free movement without tensile stress or forced movements in dry, damp and wet rooms and outdoors. Through the good
flexibility quickly and safely to install. Designed for the export-oriented engineering.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
28370 2 x 0,5 20 9,0 41,0 131,0 28430 2 x 0,5 20 9,0 41,0 131,0
28371 3 G 0,5 20 9,3 45,0 154,0 28431 3 G 0,5 20 9,3 45,0 154,0
28372 4 G 0,5 20 9,9 54,0 176,0 28432 4 G 0,5 20 9,9 54,0 176,0
28373 5 G 0,5 20 10,6 66,0 204,0 28433 5 G 0,5 20 10,6 66,0 204,0
28374 7 G 0,5 20 12,2 79,0 237,0 28434 7 G 0,5 20 12,2 79,0 237,0
28375 12 G 0,5 20 14,7 137,0 323,0 28435 12 G 0,5 20 14,7 137,0 323,0
28376 18 G 0,5 20 17,3 156,0 431,0 28436 18 G 0,5 20 17,3 156,0 431,0
28377 25 G 0,5 20 20,6 250,0 507,0 28437 25 G 0,5 20 20,6 250,0 507,0
28378 2 x 0,75 19 9,4 46,0 143,0 28438 2 x 0,75 19 9,4 46,0 143,0
28379 3 G 0,75 19 9,8 57,0 158,0 28439 3 G 0,75 19 9,8 57,0 158,0
28380 4 G 0,75 19 10,4 63,0 193,0 28440 4 G 0,75 19 10,4 63,0 193,0
28381 5 G 0,75 19 11,1 76,0 231,0 28441 5 G 0,75 19 11,1 76,0 231,0
28382 7 G 0,75 19 13,0 100,0 337,0 28442 7 G 0,75 19 13,0 100,0 337,0
28383 12 G 0,75 19 15,8 175,0 424,0 28443 12 G 0,75 19 15,8 175,0 424,0
28384 18 G 0,75 19 17,9 240,0 568,0 28444 18 G 0,75 19 17,9 240,0 568,0
28385 25 G 0,75 19 22,8 306,0 741,0 28445 25 G 0,75 19 22,8 306,0 741,0
28386 2x1 18 9,9 54,0 158,0 28446 2x1 18 9,9 54,0 158,0
28387 3G1 18 10,3 64,0 169,0 28447 3G1 18 10,3 64,0 169,0
28388 4G1 18 11,1 76,0 207,0 28448 4G1 18 11,1 76,0 207,0
28389 5G1 18 12,2 89,0 244,0 28449 5G1 18 12,2 89,0 244,0
28390 7G1 18 14,5 114,0 292,0 28450 7G1 18 14,5 114,0 292,0
28391 12 G 1 18 17,4 186,0 472,0 28451 12 G 1 18 17,4 186,0 472,0
28392 18 G 1 18 20,7 284,0 634,0 28452 18 G 1 18 20,7 284,0 634,0
28393 25 G 1 18 24,8 387,0 861,0 28453 25 G 1 18 24,8 387,0 861,0

Continuation

390
Cables according to international Approvals / PUR-Control Cables UL/CSA

JZ-600-YC-PUR tear and coolant resistant, 1000 V, Cu-screened,


EMC-preferred type, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
28394 2 x 1,5 16 10,7 64,0 166,0 28454 2 x 1,5 16 10,7 64,0 166,0
28395 3 G 1,5 16 11,2 82,0 192,0 28455 3 G 1,5 16 11,2 82,0 192,0
28396 4 G 1,5 16 12,3 99,0 246,0 28456 4 G 1,5 16 12,3 99,0 246,0
28397 5 G 1,5 16 13,3 123,0 294,0 28457 5 G 1,5 16 13,3 123,0 294,0
28398 7 G 1,5 16 16,0 148,0 392,0 28458 7 G 1,5 16 16,0 148,0 392,0
28399 12 G 1,5 16 19,6 274,0 599,0 28459 12 G 1,5 16 19,6 274,0 599,0
28400 18 G 1,5 16 23,4 386,0 817,0 28460 18 G 1,5 16 23,4 386,0 817,0
28401 25 G 1,5 16 28,2 531,0 1261,0 28461 25 G 1,5 16 28,2 531,0 1261,0
28402 2 x 2,5 14 11,8 110,0 280,0 28462 2 x 2,5 14 11,8 110,0 280,0
28403 3 G 2,5 14 12,3 148,0 301,0 28463 3 G 2,5 14 12,3 148,0 301,0
28404 4 G 2,5 14 13,4 169,0 352,0 28464 4 G 2,5 14 13,4 169,0 352,0
28405 5 G 2,5 14 14,9 220,0 433,0 28465 5 G 2,5 14 14,9 220,0 433,0
28406 7 G 2,5 14 17,9 284,0 569,0 28466 7 G 2,5 14 17,9 284,0 569,0
28407 12 G 2,5 14 21,9 470,0 864,0 28467 12 G 2,5 14 21,9 470,0 864,0
28408 18 G 2,5 14 26,1 572,0 1365,0 28468 18 G 2,5 14 26,1 572,0 1365,0
28409 25 G 2,5 14 31,9 740,0 1997,0 28469 25 G 2,5 14 31,9 740,0 1997,0
28410 2x4 12 14,3 124,0 310,0 28470 2x4 12 14,3 124,0 310,0
28411 3G4 12 15,1 178,0 396,0 28471 3G4 12 15,1 178,0 396,0
28412 4G4 12 16,7 234,0 531,0 28472 4G4 12 16,7 234,0 531,0
28413 5G4 12 18,6 284,0 704,0 28473 5G4 12 18,6 284,0 704,0
28414 7G4 12 20,0 321,0 932,0 28474 7G4 12 20,0 321,0 932,0
28415 3G6 10 17,0 245,0 633,0 28475 3G6 10 17,0 245,0 633,0
28416 4G6 10 18,7 316,0 742,0 28476 4G6 10 18,7 316,0 742,0
28417 5G6 10 20,7 442,0 1117,0 28477 5G6 10 20,7 442,0 1117,0
28418 3 G 10 8 19,6 367,0 1131,0 28478 3 G 10 8 19,6 367,0 1131,0
28419 4 G 10 8 21,9 549,0 1357,0 28479 4 G 10 8 21,9 549,0 1357,0
28420 5 G 10 8 24,1 604,0 1646,0 28480 5 G 10 8 24,1 604,0 1646,0
28421 3 G 16 6 23,5 653,0 1397,0 28481 3 G 16 6 23,5 653,0 1397,0
28422 4 G 16 6 26,4 807,0 1880,0 28482 4 G 16 6 26,4 807,0 1880,0
28423 5 G 16 6 28,8 940,0 2721,0 28483 5 G 16 6 28,8 940,0 2721,0

Dimensions and specifications may be changed without prior notice. (RN01)

391
Cables according to international Approvals / PUR/TPE-Control Cables UL/CSA

TRAYCONTROL 670 HDP / 670-C HDP flexible,


oil-resistant, open installation (TC-ER), NFPA 79 Edition 2012

Technical data Cable structure Properties


TPE motor supply cable acc. to Bare copper-conductor, fine-wire self-extinguishing and flame retardant
UL-Std.1277 and UL-Std.2277 with AWG dimensions acc. to CSA FT4
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -40C bis +105C with transparent nylon skin cadmium-free and contain no silicone
Nominal voltage Core identification to DIN VDE 0293 and free from substances harmful to
TC 600 V black cores with continuous white the wetting properties of lacquers
AWM 1000 V numbering Tests
TC Wind Turbine (WTTC) 1000 V GN-YE conductor in the outer layer UL:
Test voltage 4000 V Cores stranded in layers with optimal TC-ER, WTTC, MTW, NFPA 79 2012,
Minimum bending radius lay-length UL AWM 105C, OIL RES I & II,
7,5 cable Separator 75 C wet Bus Drop Cable, Class 1 Div. 2
Coupling resistance (-C-type) Outer sheath of special TPE per NEC Art. 336, 318, 501
max. 250 Ohm/km Sheath colour orange (RAL 2003) CSA:
with length marking in feet c (UL) CIC-TC FT4,
C-Type AWM I/II A/B FT4
Screening with braid of tinned copper
wires, optimal coverage, approx. 85% Note
HDP = Heavy Duty Power

Application
HELUKABEL TRAYCONTROL 670 HDP / 670-C-HDP are multi-conductor severe duty motor supply cables with Bus Drop, TC-ER and CIC/TC
approval. Superior oil performance for long cable life and permitted to be used in hazardous (classified) locations Class I Div 2 per NEC 336, 318 and
501. Special extruded sheath and fine copper stranding approved for exposed run, pipes and burial installation. Excellent flexibility and easier to pull
than standard tray cables. Suitable for installation in the open unprotected installation on cable tray and from cable tray to machines according to
NFPA 79 edition 2012.
Recommended Applications: Motor connections in industrial and automation environments, machine tool, automotive and renewable energies.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TRAYCONTROL 670 HDP TRAYCONTROL 670-C HDP
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
66820 4x1 18 8,4 39,0 103,0 66829 4x1 18 9,8 52,0 133,0
66821 4 G 1,32 16 9,2 51,0 133,0 66830 4 G 1,32 16 10,5 72,0 159,0
66822 4 G 2,08 14 10,0 80,0 170,0 66831 4 G 2,08 14 11,7 115,0 222,0
66823 4 G 3,31 12 11,2 127,0 229,0 66832 4 G 3,31 12 12,8 179,0 283,0
66824 4G6 10 15,2 230,0 393,0 66833 4G6 10 16,9 256,0 460,0
66825 4 G 10 8 19,3 384,0 626,0 66834 4 G 10 8 22,1 426,0 741,0
66826 4 G 16 6 22,4 614,0 885,0 66835 4 G 16 6 26,2 657,0 1059,0
66827 4 G 25 4 26,7 960,0 1301,0 66836 4 G 25 4 30,8 1026,0 1497,0
66828 4 G 35 2 31,5 1344,0 1983,0 66837 4 G 35 2 35,0 1412,0 2058,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

392
UL/CSA HALOGEN-FREE CONTROL CABLES
Cables according to international Approvals / Halogen-free Control Cables UL/CSA

MEGAFLEX 500 halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, meter marking

Technical data Cable structure Properties


Halogen-free flexible control cable Bare copper-conductor, to Highly flame-retardant
adapted to DIN VDE 0295 cl.5, fine-wire, Resistant to oils and greases
DIN VDE 0285-525-3-11/ BS 6360 cl.5, IEC 60228 cl.5 Resistant to UV and weathering
DIN EN 50525-3-11, Core insulation of halogen-free Hydrolysis resistant
to UL-Style 20939, UL-Std.758 special polymer Flexible, abrasion- and wear-resistant
Temperature range Core identification to DIN VDE 0293 Ozone-resistant, recycleable
flexing -30C to +80C black cores with continuous white The materials used in manufacture are
fixed installation -40C to +80C numbering cadmium-free and contain no silicone
Nominal voltage GN-YE conductor, 3 cores and above and free from substances harmful to
U0/U 300/500 V in the outer layer the wetting properties of lacquers
UL/CSA 600 V Cores stranded in layers with Tests
Test voltage 3000 V optimal lay-length Flame test acc. to DIN VDE 0482-332-3-24,
Minimum bending radius Outer sheath of halogen-free BS 4066 part 3, DIN EN 60332-3-24,
flexing 10x cable special polymer IEC 60332-3-24 (previously DIN VDE 0472
fixed installation 4x cable Sheath colour grey (RAL 7001) part 804 test method C)
Flexibility with meter marking Self-extinguishing and flame retardant
Alternate bending test acc. to LS0H= Low Smoke Zero Halogen acc. to DIN VDE 0482-332-1-2,
DIN VDE 0473-396 / DIN EN 50396 DIN EN 60332-1-2 / IEC 60332-1 (previously
Note DIN VDE 0472 part 804 test method B),
G = with green-yellow conductor CSA FT1
x = without green-yellow conductor (OZ) Corrosiveness of combustion gases
Also available as a 0,6/1 kV cable acc. to NF X 10-702
MEGAFLEX 600 Halogen-free acc. to DIN VDE 0482
AWG sizes are approximate equivalent part 267 / DIN EN 50267-2-1 / IEC 60754-1
values. The actual cross-section is in mm. (equivalent DIN VDE 0472 part 815)
screened analogue type: Smoke density acc. to DIN VDE 0482
MEGAFLEX 500-C, confer page 398 part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)
Oil-resistant to DIN VDE 0473-811-404/
DIN EN 60811-404
Hydrolysis-resistant to DIN EN 61234-1
Ozone-resistant to
DIN VDE 0473-811-403/DIN EN 60811-403

Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress, for high
mechanical strain. As a measuring and control cable primarily in machinery and plant construction, in air-conditoning systems, at the warehouse and
conveyor systems, in ship-building and in the renewable energies such as in the construction of wind power stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
13344 2 x 0,5 20 5,0 9,6 43,0 13352 8 G 0,5 20 8,0 38,0 101,0
13345 3 G 0,5 20 5,3 14,4 50,0 13353 10 G 0,5 20 8,8 48,0 121,0
13346 3 x 0,5 20 5,3 14,4 50,0 13354 12 G 0,5 20 9,1 58,0 142,0
13347 4 G 0,5 20 5,7 19,0 60,0 13355 16 G 0,5 20 10,0 76,0 183,0
13348 4 x 0,5 20 5,7 19,0 60,0 13356 18 G 0,5 20 10,7 86,0 204,0
13349 5 G 0,5 20 6,2 24,0 71,0 13357 20 G 0,5 20 11,2 96,0 227,0
13350 5 x 0,5 20 6,2 24,0 71,0 13359 25 G 0,5 20 12,7 120,0 283,0
13351 7 G 0,5 20 7,4 33,6 84,0 13360 30 G 0,5 20 13,5 144,0 324,0

Continuation

394
Cables according to international Approvals / Halogen-free Control Cables UL/CSA

MEGAFLEX 500 halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
13361 34 G 0,5 20 14,5 163,0 367,0 13437 7 G 2,5 14 12,1 168,0 316,0
13362 37 G 0,5 20 14,5 178,0 381,0 13438 8 G 2,5 14 13,2 192,0 370,0
13363 41 G 0,5 20 15,8 197,0 417,0 13439 10 G 2,5 14 14,6 240,0 451,0
13364 42 G 0,5 20 15,8 202,0 454,0 13440 12 G 2,5 14 15,2 288,0 499,0
13365 50 G 0,5 20 17,3 240,0 519,0 13441 16 G 2,5 14 16,8 384,0 720,0
13366 61 G 0,5 20 18,5 293,0 635,0 13442 18 G 2,5 14 18,1 432,0 769,0
13367 65 G 0,5 20 19,4 312,0 694,0 13443 20 G 2,5 14 19,0 480,0 911,0
13368 2 x 0,75 19 5,4 14,4 47,0 13444 25 G 2,5 14 22,2 600,0 1047,0
13369 3 G 0,75 19 5,7 21,6 56,0 13445 30 G 2,5 14 22,9 720,0 1280,0
13370 3 x 0,75 19 5,7 21,6 56,0 13446 2x4 12 9,2 77,0 199,0
13371 4 G 0,75 19 6,2 29,0 69,0 13447 3G4 12 9,9 115,0 247,0
13372 4 x 0,75 19 6,2 29,0 69,0 13448 4G4 12 11,0 154,0 299,0
13373 5 G 0,75 19 6,8 36,0 83,0 13449 5G4 12 12,1 192,0 369,0
13374 5 x 0,75 19 6,8 36,0 83,0 13450 7G4 12 13,3 269,0 463,0
13375 7 G 0,75 19 8,1 50,0 114,0 13451 8G4 12 15,9 307,0 601,0
13376 7 x 0,75 19 8,1 50,0 114,0 13452 10 G 4 12 17,3 384,0 698,0
13377 8 G 0,75 19 8,9 58,0 136,0 13453 12 G 4 12 18,3 461,0 790,0
13378 10 G 0,75 19 9,6 72,0 172,0 13454 16 G 4 12 20,2 614,0 1130,0
13379 12 G 0,75 19 9,9 86,0 183,0 13455 18 G 4 12 21,8 691,0 1280,0
13380 16 G 0,75 19 11,2 115,0 241,0 13456 2x6 10 10,8 115,0 266,0
13381 18 G 0,75 19 11,9 130,0 266,0 13457 3G6 10 11,7 173,0 360,0
13382 20 G 0,75 19 12,6 144,0 291,0 13458 4G6 10 13,0 230,0 429,0
13383 25 G 0,75 19 14,1 180,0 374,0 13459 5G6 10 14,5 288,0 529,0
13384 30 G 0,75 19 15,4 216,0 450,0 13460 7G6 10 16,0 403,0 631,0
13385 34 G 0,75 19 16,4 245,0 517,0 13461 2 x 10 8 14,0 192,0 440,0
13386 37 G 0,75 19 16,4 260,0 541,0 13462 3 G 10 8 15,0 288,0 550,0
13387 41 G 0,75 19 17,6 296,0 611,0 13463 4 G 10 8 16,8 384,0 708,0
13388 42 G 0,75 19 17,6 302,0 621,0 13464 5 G 10 8 18,7 480,0 862,0
13389 50 G 0,75 19 19,8 360,0 742,0 13465 7 G 10 8 20,6 672,0 1124,0
13390 61 G 0,75 19 20,9 439,0 853,0 13466 2 x 16 6 16,5 307,0 642,0
13392 65 G 0,75 19 21,8 468,0 909,0 13467 3 G 16 6 17,6 461,0 830,0
13393 2x1 18 5,7 19,2 63,0 13468 4 G 16 6 19,7 641,0 1060,0
13394 3G1 18 6,0 29,0 74,0 13469 5 G 16 6 21,9 768,0 1270,0
13395 3x1 18 6,0 29,0 74,0 13470 7 G 16 6 24,4 1075,0 1794,0
13396 4G1 18 6,6 38,4 90,0 13471 3 G 25 4 22,5 720,0 1190,0
13397 4x1 18 6,6 38,4 90,0 13472 4 G 25 4 25,2 960,0 1594,0
13398 5G1 18 7,2 48,0 109,0 13473 5 G 25 4 27,9 1200,0 2014,0
13399 7G1 18 8,6 67,0 151,0 13474 3 G 35 2 26,3 1008,0 1590,0
13400 8G1 18 9,4 77,0 184,0 13475 4 G 35 2 28,5 1344,0 2200,0
13401 10 G 1 18 10,4 96,0 224,0 13476 5 G 35 2 31,2 1680,0 2693,0
13402 12 G 1 18 10,7 115,0 243,0 13477 3 G 50 1 30,2 1440,0 2571,0
13403 16 G 1 18 12,0 154,0 314,0 13478 4 G 50 1 34,0 1920,0 3087,0
13404 18 G 1 18 12,7 173,0 361,0 13479 5 G 50 1 37,8 2400,0 3980,0
13405 20 G 1 18 13,5 192,0 387,0 13480 3 G 70 2/0 37,0 2016,0 3207,0
13406 25 G 1 18 15,2 240,0 496,0 13481 4 G 70 2/0 41,5 2688,0 4077,0
13407 34 G 1 18 17,4 326,0 670,0 13482 5 G 70 2/0 46,2 3360,0 5501,0
13408 37 G 1 18 17,4 355,0 713,0 13483 3 G 95 3/0 41,4 2736,0 4708,0
13409 41 G 1 18 18,9 394,0 784,0 13484 4 G 95 3/0 46,2 3648,0 5590,0
13410 42 G 1 18 18,9 403,0 824,0 13485 5 G 95 3/0 51,5 4560,0 6972,0
13411 50 G 1 18 21,0 480,0 952,0 13486 3 G 120 4/0 45,7 3456,0 5515,0
13412 61 G 1 18 22,2 586,0 1140,0 13487 4 G 120 4/0 51,2 4608,0 7100,0
13413 65 G 1 18 23,2 628,0 1201,0
N
13488 3 G 150 300 kcmil 52,8 4320,0 6279,0
13414 2 x 1,5 16 6,3 29,0 70,0 13489 4 G 150 300 kcmil 58,3 5760,0 7781,0
13415 3 G 1,5 16 6,6 43,0 94,0
13416 3 x 1,5 16 6,6 43,0 94,0
13417 4 G 1,5 16 7,2 58,0 112,0
13418 5 G 1,5 16 7,9 72,0 141,0
13419 7 G 1,5 16 9,5 101,0 191,0
13420 8 G 1,5 16 10,4 115,0 224,0
13421 10 G 1,5 16 11,3 144,0 282,0
13422 12 G 1,5 16 11,7 173,0 311,0
13423 16 G 1,5 16 13,3 230,0 392,0
13425 18 G 1,5 16 14,0 259,0 450,0
13426 20 G 1,5 16 14,9 288,0 497,0
13427 25 G 1,5 16 16,8 360,0 630,0
13428 34 G 1,5 16 19,4 490,0 842,0
13429 37 G 1,5 16 19,4 533,0 897,0
13430 50 G 1,5 16 23,4 720,0 1277,0
13431 61 G 1,5 16 24,8 878,0 1460,0
13432 65 G 1,5 16 25,8 936,0 1612,0
13433 2 x 2,5 14 7,6 48,0 118,0
13434 3 G 2,5 14 8,3 72,0 151,0
13435 4 G 2,5 14 9,1 96,0 181,0
13436 5 G 2,5 14 10,2 120,0 224,0

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

395
Cables according to international Approvals / Halogen-free Control Cables UL/CSA

MEGAFLEX 600 halogen-free, flame retardant, oil-resistant, UV-resistant,


flexible, meter marking

Technical data Cable structure Properties


Halogen-free flexible control cable to Bare copper, fine wire conductors, to Halogen-free
UL-Style 20234, UL-Std.758 DIN VDE 0295 cl.5, BS 6360 cl.5 and Highly flame-retardant
Temperature range IEC 60228 cl.5 Resistant to oils and greases
flexing -30C to +80C Core insulation of halogen-free special Resistant to UV and weathering
fixed installation -40C to +80C polymer Hydrolysis resistant
Nominal voltage U0/U 600/1000 V Core identification to DIN VDE 0293 Flexible, abrasion- and wear-resistant
Test voltage 4000 V black cores with continuous white Ozone-resistantRecycleable
Minimum bending radius numbering Tests
flexing 10x cable GN-YE conductor, 3 cores and above Flame test acc. to DIN VDE 0482-332-3-24,
fixed installation 4x cable in the outer layer BS 4066 part 3, DIN EN 60332-3-24,
Flexibility Cores stranded in layer with optimal IEC 60332-3-24 (previously DIN VDE 0472
Alternate bending test acc. to lay-length part 804 test method C)
DIN VDE 0473-396 / DIN EN 50396 Outer sheath, halogen-free special polymer Self-extinguishing and flame retardant
Sheath colour black (RAL 9005) acc. to DIN VDE 0482-332-1-2,
with meter marking DIN EN 60332-1-2/IEC 60332-1 (previously
DIN VDE 0472 part 804 test method B)
The materials used in manufacture are
cadmium-free and contain no silicone
and free from substances harmful to
the wetting properties of lacquers
Corrosiveness of combustion gases
acc. to NF X 10-702
Halogen-free acc. to DIN VDE 0482
part 267/ EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2/
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)
Oil-resistant to DIN VDE 0473-811-404/
DIN EN 60811-404
Hydrolysis-resistant to DIN EN 61234-1
Ozone-resistant to
DIN VDE 0473-811-403/DIN EN 60811-403

Note
G = with green-yellow conductor
x = without green-yellow conductor
screened analogue type:
MEGAFLEX 600-C, confer page 400

Application
For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile
stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate
engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
13200 2 x 0,5 20 6,4 9,6 56,0 13208 8 G 0,5 20 10,7 38,0 150,0
13201 3 G 0,5 20 6,8 14,4 68,0 13209 10 G 0,5 20 11,6 48,0 176,0
13202 3 x 0,5 20 6,8 14,4 68,0 13210 12 G 0,5 20 12,2 58,0 200,0
13203 4 G 0,5 20 7,6 19,0 100,0 13211 16 G 0,5 20 13,7 76,0 250,0
13204 4 x 0,5 20 7,6 19,0 100,0 13212 18 G 0,5 20 14,4 86,0 276,0
13205 5 G 0,5 20 8,2 24,0 117,0 13213 20 G 0,5 20 15,3 96,0 293,0
13206 5 x 0,5 20 8,2 24,0 117,0 13214 25 G 0,5 20 17,2 120,0 335,0
13207 7 G 0,5 20 9,8 33,6 138,0 13215 30 G 0,5 20 18,0 144,0 348,0

Continuation

396
Cables according to international Approvals / Halogen-free Control Cables UL/CSA

MEGAFLEX 600 halogen-free, flame retardant, oil-resistant, UV-resistant,


flexible, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
13216 34 G 0,5 20 19,8 163,0 520,0 13281 25 G 1,5 16 23,9 360,0 730,0
13217 37 G 0,5 20 15,0 178,0 561,0 13282 34 G 1,5 16 27,2 490,0 950,0
13218 41 G 0,5 20 21,3 197,0 590,0 13283 37 G 1,5 16 29,4 533,0 1094,0
13219 42 G 0,5 20 21,2 202,0 595,0 13284 50 G 1,5 16 32,5 720,0 1400,0
13220 50 G 0,5 20 23,4 240,0 715,0 13285 61 G 1,5 16 35,7 878,0 1700,0
13221 61 G 0,5 20 26,0 293,0 840,0 13286 65 G 1,5 16 36,8 936,0 1900,0
13222 65 G 0,5 20 26,8 312,0 880,0 13287 2 x 2,5 14 9,4 48,0 160,0
13223 2 x 0,75 19 6,8 14,4 66,0 13288 3 G 2,5 14 9,9 72,0 175,0
13224 3 G 0,75 19 7,2 21,6 74,0 13289 4 G 2,5 14 11,1 96,0 203,0
13225 3 x 0,75 19 7,2 21,6 74,0 13290 5 G 2,5 14 12,4 120,0 251,0
13226 4 G 0,75 19 8,0 29,0 126,0 13291 7 G 2,5 14 15,0 168,0 330,0
13227 4 x 0,75 19 8,0 29,0 126,0 13292 8 G 2,5 14 16,1 192,0 400,0
13228 5 G 0,75 19 8,8 36,0 140,0 13293 10 G 2,5 14 17,0 240,0 461,0
13229 5 x 0,75 19 8,8 36,0 140,0 13294 12 G 2,5 14 18,4 288,0 553,0
13230 7 G 0,75 19 10,7 50,0 190,0 13295 16 G 2,5 14 19,4 384,0 742,0
13231 7 x 0,75 19 10,7 50,0 190,0 13296 18 G 2,5 14 22,0 432,0 795,0
13232 8 G 0,75 19 11,5 58,0 212,0 13297 20 G 2,5 14 32,2 480,0 924,0
13233 10 G 0,75 19 12,7 72,0 238,0 13298 25 G 2,5 14 26,9 600,0 1110,0
13234 12 G 0,75 19 13,1 86,0 257,0 13299 30 G 2,5 14 28,1 720,0 1370,0
13235 16 G 0,75 19 14,6 115,0 304,0 13300 2x4 12 11,4 77,0 180,0
13236 18 G 0,75 19 15,6 130,0 362,0 13301 3G4 12 12,3 115,0 230,0
13237 20 G 0,75 19 16,6 144,0 394,0 13302 4G4 12 13,8 154,0 310,0
13238 25 G 0,75 19 18,9 180,0 486,0 13303 5G4 12 15,3 192,0 410,0
13239 30 G 0,75 19 15,4 216,0 450,0 13304 7G4 12 16,8 269,0 540,0
13241 34 G 0,75 19 21,5 245,0 638,0 13305 8G4 12 20,0 307,0 710,0
13242 37 G 0,75 19 21,5 260,0 696,0 13306 10 G 4 12 21,6 384,0 760,0
13243 41 G 0,75 19 23,2 296,0 750,0 13307 12 G 4 12 22,9 461,0 860,0
13244 42 G 0,75 19 23,2 302,0 770,0 13308 16 G 4 12 23,6 614,0 910,0
13245 50 G 0,75 19 25,6 360,0 895,0 13309 18 G 4 12 24,2 691,0 980,0
13246 61 G 0,75 19 28,2 439,0 1070,0 13310 2x6 10 13,1 115,0 205,0
13247 65 G 0,75 19 29,0 468,0 1110,0 13311 3G6 10 14,1 173,0 370,0
13248 2x1 18 7,4 19,2 80,0 13312 4G6 10 15,6 230,0 430,0
13249 3G1 18 8,0 29,0 96,0 13313 5G6 10 17,3 288,0 650,0
13250 3x1 18 8,0 29,0 96,0 13314 7G6 10 19,3 403,0 860,0
13251 4G1 18 8,8 38,4 100,0 13315 2 x 10 8 15,4 192,0 330,0
13252 4x1 18 8,8 38,4 100,0 13316 3 G 10 8 16,5 288,0 660,0
13253 5G1 18 9,8 48,0 130,0 13317 4 G 10 8 18,1 384,0 790,0
13254 7G1 18 11,7 67,0 170,0 13318 5 G 10 8 20,5 480,0 960,0
13255 8G1 18 12,8 77,0 230,0 13319 7 G 10 8 22,5 672,0 1300,0
13256 10 G 1 18 14,3 96,0 270,0 13320 2 x 16 6 18,3 307,0 580,0
13257 12 G 1 18 14,5 115,0 290,0 13321 3 G 16 6 19,6 461,0 700,0
13258 16 G 1 18 16,5 154,0 360,0 13322 4 G 16 6 21,7 641,0 1100,0
13259 18 G 1 18 17,3 173,0 405,0 13323 5 G 16 6 24,2 768,0 1600,0
13260 20 G 1 18 18,4 192,0 450,0 13324 7 G 16 6 25,7 1075,0 1890,0
13261 25 G 1 18 21,1 240,0 570,0 13325 3 G 25 4 24,0 720,0 1450,0
13262 34 G 1 18 24,0 326,0 750,0 13326 4 G 25 4 26,9 960,0 1600,0
13263 37 G 1 18 24,3 355,0 790,0 13327 5 G 25 4 29,4 1200,0 2050,0
13264 41 G 1 18 25,9 394,0 890,0 13328 3 G 35 2 26,2 1008,0 1900,0
13265 42 G 1 18 25,9 403,0 900,0 13329 4 G 35 2 29,4 1344,0 2400,0
13266 50 G 1 18 28,5 480,0 1100,0 13330 5 G 35 2 32,8 1680,0 2900,0
13267 61 G 1 18 31,4 586,0 1266,0 13331 3 G 50 1 31,6 1440,0 2700,0
13268 65 G 1 18 32,5 628,0 1560,0
N
13332 4 G 50 1 35,5 1920,0 3400,0
13269 2 x 1,5 16 8,4 29,0 95,0 13333 5 G 50 1 40,0 2400,0 4361,0
13270 3 G 1,5 16 9,1 43,0 112,0 13334 3 G 70 2/0 36,7 2016,0 3300,0
13271 3 x 1,5 16 9,1 43,0 112,0 13335 4 G 70 2/0 40,7 2688,0 4400,0
13272 4 G 1,5 16 9,9 58,0 139,0 13336 5 G 70 2/0 45,7 3360,0 5807,0
13273 5 G 1,5 16 11,0 72,0 170,0 13337 3 G 95 3/0 41,2 2736,0 5050,0
13274 7 G 1,5 16 13,3 101,0 225,0 13338 4 G 95 3/0 46,2 3648,0 6010,0
13275 8 G 1,5 16 14,5 115,0 250,0 13339 5 G 95 3/0 50,7 4560,0 7752,0
13276 10 G 1,5 16 16,1 144,0 300,0 13340 3 G 120 4/0 45,9 3456,0 5620,0
13277 12 G 1,5 16 16,6 173,0 370,0 13341 4 G 120 4/0 50,3 4608,0 7500,0
13278 16 G 1,5 16 18,5 230,0 450,0 13342 3 G 150 300 kcmil 52,7 4320,0 6390,0
13279 18 G 1,5 16 19,7 259,0 520,0 13343 4 G 150 300 kcmil 58,8 5760,0 6840,0
13280 20 G 1,5 16 20,9 288,0 600,0

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

397
Cables according to international Approvals / Halogen-free Control Cables UL/CSA

MEGAFLEX 500-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, screened, EMC-preferred types, meter marking

Technical data Cable structure Properties


Halogen-free flexible control cable Bare copper, fine wire conductors, to Halogen-free
adapted to DIN VDE 0295 cl.5, BS 6360 cl.5 and Highly flame-retardant
DIN VDE 0285-525-3-11 / IEC 60228 cl.5 Resistant to oils and greases
DIN EN 50525-3-11, Core insulation of halogen-free Resistant to UV and weathering
to UL-Style 20939, UL-Std.758 special polymer Flexible, abrasion- and wear-resistant
Temperature range Core identification to DIN VDE 0293 Ozone-resistant
flexing -30C to +80C black cores with continuous white Recycleable
fixed installation -40C to +80C numbering The materials used in manufacture are
Nominal voltage GN-YE conductor, 3 cores and above cadmium-free and contain no silicone
U0/U 300/500 V in the outer layer and free from substances harmful to
UL/CSA 600 V Cores stranded in layers with the wetting properties of lacquers
Test voltage 3000 V optimal lay-length Tests
Coupling resistance Separating foil Flame test acc. to DIN VDE 0482-332-3-24,
max. 250 Ohm/km Tinned copper braided screen, BS 4066 part 3, DIN EN 60332-3-24,
Minimum bending radius approx. 85% coverage IEC 60332-3-24 (previously DIN VDE 0472
flexing 10x cable Outer sheath of halogen-free part 804 test method C)
fixed installation 4x cable special polymer Self-extinguishing and flame retardant
Flexibility Sheath colour grey (RAL 7001) acc. to DIN VDE 0482-332-1-2,
Alternate bending test acc. to with meter marking DIN EN 60332-1-2, IEC 60332-1 (previously
DIN VDE 0473-396 / DIN EN 50396 LS0H= Low Smoke Zero Halogen DIN VDE 0472 part 804 test method B)
CSA FT1
Note Corrosiveness of combustion gases acc. to
G = with green-yellow conductor NF X 10-702
x = without green-yellow conductor (OZ) Halogen-free acc. to DIN VDE 0482
AWG sizes are approximate equivalent part 267, DIN EN 50267-2-1, IEC 60754-1
values. The actual cross-section is in mm. (equivalent DIN VDE 0472 part 815)
unscreened analogue type: Smoke density acc. to DIN VDE 0482
MEGAFLEX 500, confer page 394 part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)
Oil-resistant to DIN VDE 0473-811-404 /
DIN EN 60811-404
Hydrolysis resistant to DIN EN 61234-1
Ozone-resistant to DIN VDE 0473-811-403/
DIN EN 60811-403

Application
For fixed installation or flexible application that does not permanently recurring free movement without forced motion and without tensile stress, for
high mechanical strain. As a measuring and control cable e. g. in machine and plant engineering, air conditioning in the warehouse and materials
handling, shipbuilding and in the newable energies such as wind power stations.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
13500 2 x 0,5 20 5,7 35,0 46,0 13508 8 G 0,5 20 8,5 80,0 116,0
13501 3 G 0,5 20 6,0 42,0 56,0 13509 10 G 0,5 20 9,3 94,0 135,0
13502 3 x 0,5 20 6,0 42,0 56,0 13510 12 G 0,5 20 9,6 108,0 158,0
13503 4 G 0,5 20 6,5 47,0 62,0 13511 16 G 0,5 20 10,7 129,0 210,0
13504 4 x 0,5 20 6,5 47,0 62,0 13512 18 G 0,5 20 11,2 145,0 216,0
13505 5 G 0,5 20 7,0 56,0 75,0 13514 20 G 0,5 20 11,9 172,0 240,0
13506 5 x 0,5 20 7,0 56,0 75,0 13515 25 G 0,5 20 13,4 240,0 315,0
13507 7 G 0,5 20 7,9 69,0 98,0

Continuation

398
Cables according to international Approvals / Halogen-free Control Cables UL/CSA

MEGAFLEX 500-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, screened, EMC-preferred types, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
13516 2 x 0,75 19 6,1 40,0 60,0 13566 5 G 2,5 14 10,9 181,0 256,0
13517 3 G 0,75 19 6,4 52,0 68,0 13567 7 G 2,5 14 12,9 255,0 345,0
13518 3 x 0,75 19 6,4 52,0 68,0 13568 8 G 2,5 17 13,8 285,0 390,0
13519 4 G 0,75 19 6,9 60,0 78,0 13569 10 G 2,5 14 15,8 340,0 482,0
13520 4 x 0,75 19 6,9 60,0 78,0 13570 12 G 2,5 14 15,9 441,0 572,0
13521 5 G 0,75 19 7,4 71,0 95,0 13571 2x4 12 9,8 120,0 220,0
13522 5 x 0,75 19 7,4 71,0 95,0 13572 3G4 12 10,6 174,0 251,0
13523 7 G 0,75 19 8,6 91,0 130,0 13573 4G4 12 11,5 230,0 305,0
13524 7 x 0,75 19 8,6 91,0 130,0 13574 5G4 12 12,7 273,0 388,0
13525 8 G 0,75 19 9,4 110,0 145,0 13575 7G4 12 13,9 316,0 504,0
13526 10 G 0,75 19 10,2 137,0 180,0 13576 2x6 10 11,5 173,0 270,0
13527 12 G 0,75 19 10,4 142,0 203,0 13577 3G6 10 12,4 240,0 351,0
13528 16 G 0,75 19 11,6 200,0 275,0 13578 4G6 10 13,8 305,0 464,0
13529 18 G 0,75 19 12,4 212,0 290,0 13579 5G6 10 15,7 439,0 546,0
13530 20 G 0,75 19 12,9 238,0 320,0 13580 7G6 10 16,6 505,0 670,0
13531 25 G 0,75 19 14,8 281,0 413,0 13581 2 x 10 8 14,9 255,0 461,0
13532 2x1 18 6,4 50,0 66,0 13582 3 G 10 8 15,9 350,0 574,0
13533 3G1 18 6,7 60,0 80,0 13583 4 G 10 8 17,8 535,0 785,0
13534 3x1 18 6,7 60,0 80,0 13584 5 G 10 8 19,6 592,0 914,0
13535 4G1 18 7,3 71,0 100,0 13585 7 G 10 8 21,6 810,0 1308,0
13536 4x1 18 7,3 71,0 100,0 13586 2 x 16 6 17,3 422,0 670,0
13537 5G1 18 7,8 88,0 130,0 13587 3 G 16 6 18,5 585,0 911,0
13538 7G1 18 9,1 111,0 160,0 13588 4 G 16 6 20,8 740,0 1105,0
13539 8G1 18 9,9 127,0 197,0 13589 5 G 16 6 22,9 895,0 1293,0
13540 10 G 1 18 10,8 150,0 232,0 13590 7 G 16 6 25,0 1282,0 2149,0
13541 12 G 1 18 11,2 184,0 260,0 13591 4 G 25 4 26,2 1140,0 1911,0
13542 16 G 1 18 12,3 209,0 346,0 13592 4 x 35 2 30,4 1576,0 2542,0
13543 18 G 1 18 13,2 260,0 382,0 13593 4 G 50 1 34,6 2155,0 3550,0
13544 20 G 1 18 13,8 317,0 440,0 13594 4 G 70 2/0 41,3 3120,0 4939,0
13545 25 G 1 18 15,8 349,0 540,0 13595 4 G 95 3/0 46,2 4043,0 6690,0
13546 2 x 1,5 16 7,0 63,0 88,0 13596 4 G 120 4/0 51,0 5069,0 8453,0
13547 3 G 1,5 16 7,3 80,0 100,0 13597 4 G 150 300 kcmil 59,0 5792,0 9104,0
13548 3 x 1,5 16 7,3 80,0 100,0
13549 4 G 1,5 16 7,9 97,0 125,0
13550 5 G 1,5 16 8,6 119,0 158,0
13552 7 G 1,5 16 10,2 147,0 210,0
13554 8 G 1,5 16 11,1 170,0 244,0
13556 10 G 1,5 16 12,0 193,0 315,0
13557 12 G 1,5 16 12,5 267,0 340,0
13558 16 G 1,5 16 13,8 315,0 424,0
13559 18 G 1,5 16 15,0 374,0 480,0
13560 20 G 1,5 16 15,7 396,0 545,0
13561 25 G 1,5 16 18,0 526,0 702,0
13562 2 x 2,5 14 8,3 96,0 132,0
13563 3 G 2,5 14 9,0 144,0 168,0
13565 4 G 2,5 14 9,8 148,0 195,0

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X. N


Cable Gland - HELUTOP HT-E

399
Cables according to international Approvals / Halogen-free Control Cables UL/CSA

MEGAFLEX 600-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, meter marking

Technical data Cable structure Properties


Halogen-free flexible control cable to Bare copper, fine wire conductors, to Halogen-free
UL-Style 20234, UL-Std.758 DIN VDE 0295 cl.5, BS 6360 cl.5 and Highly flame-retardant
Temperature range IEC 60228 cl.5 Resistant to oils and greases
flexing -30C to +80C Core insulation of halogen-free special Resistant to UV and weathering
fixed installation -40C to +80C polymer Flexible, abrasion- and wear-resistant
Nominal voltage U0/U 600/1000 V Core identification to DIN VDE 0293 Ozone-resistant
Test voltage 4000 V black cores with continuous white Recycleable
Minimum bending radius numbering Tests
flexing 10x cable GN-YE conductor, 3 cores and above Flame test acc. to DIN VDE 0482-332-3-24,
fixed installation 4x cable in the outer layer BS 4066 part 3, DIN EN 60332-3-24,
Flexibility Cores stranded in layer with optimal IEC 60332-3-24 (previously DIN VDE 0472
Alternate bending test acc. to lay-length part 804 test method C)
DIN VDE 0473-396 / DIN EN 50396 Separating foil Self-extinguishing and flame retardant
Coupling resistance Tinned copper braided screening, acc. to DIN VDE 0482-332-1-2,
max. 250 Ohm/km coverage approx. 85% DIN EN 60332-1-2/IEC 60332-1 (previously
Outer sheath, halogen-free special polymer DIN VDE 0472 part 804 test method B)
Sheath colour black (RAL 9005) The materials used in manufacture are
with meter marking cadmium-free and contain no silicone
and free from substances harmful to
the wetting properties of lacquers
Corrosiveness of combustion gases
acc. to NF X 10-702
Halogen-free according to DIN VDE 0482
part 267/ EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2/
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)
Oil-resistant to
DIN VDE 0473-811-404/DIN EN 60811-404
hydrolysebestndig nach DIN EN 61234-1
Ozone-resistant to
DIN VDE 0473-811-403/DIN EN 60811-403

Note
G = with green-yellow conductor
x = without green-yellow conductor
unscreened analogue type:
MEGAFLEX 600, confer page 396

Application
For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motionand without tensile stress,
for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate
engineering,in foundries and steel mills. Especially suited for wind power plant and computer equipment.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
15217 2 x 0,5 20 6,9 35,0 46,0 15225 10 G 0,5 20 12,1 94,0 135,0
15218 3 G 0,5 20 7,3 42,0 56,0 15226 12 G 0,5 20 12,7 108,0 158,0
15219 3 x 0,5 20 7,3 42,0 56,0 15227 18 G 0,5 20 14,9 145,0 216,0
15220 4 G 0,5 20 8,1 47,0 62,0 15228 20 G 0,5 20 15,8 172,0 240,0
15221 4 x 0,5 20 8,1 47,0 62,0 15229 25 G 0,5 20 17,7 240,0 315,0
15222 5 G 0,5 20 8,7 56,0 75,0 15230 2 x 0,75 18 7,3 40,0 60,0
15223 5 x 0,5 20 8,7 56,0 75,0 15231 3 G 0,75 18 7,7 52,0 68,0
15224 7 G 0,5 20 10,3 69,0 98,0 15232 3 x 0,75 18 7,7 52,0 68,0

Continuation

400
Cables according to international Approvals / Halogen-free Control Cables UL/CSA

MEGAFLEX 600-C halogen-free, flame retardant, oil-resistant,


UV-resistant, flexible, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
15233 4 G 0,75 18 8,5 60,0 78,0 15259 7 G 1,5 16 13,9 147,0 210,0
15234 4 x 0,75 18 8,5 60,0 78,0 15260 10 G 1,5 16 16,7 193,0 315,0
15235 5 G 0,75 18 9,3 71,0 95,0 15261 12 G 1,5 16 17,2 267,0 340,0
15236 5 x 0,75 18 9,3 71,0 95,0 15262 18 G 1,5 16 20,5 374,0 480,0
15237 7 G 0,75 18 10,7 91,0 130,0 15263 20 G 1,5 16 21,7 396,0 545,0
15238 7 x 0,75 18 10,7 91,0 130,0 15264 25 G 1,5 16 24,7 526,0 702,0
15239 12 G 0,75 18 13,1 142,0 203,0 15265 2 x 2,5 14 10,2 96,0 132,0
15240 18 G 0,75 18 16,2 212,0 290,0 15266 3 G 2,5 14 10,7 144,0 168,0
15241 20 G 0,75 18 17,2 238,0 320,0 15267 4 G 2,5 14 11,9 148,0 195,0
15242 25 G 0,75 18 19,5 281,0 413,0 15268 5 x 2,5 14 13,2 181,0 256,0
15243 2x1 17 8,0 50,0 66,0 15269 7 G 2,5 14 15,8 255,0 345,0
15244 3G1 17 8,6 60,0 80,0 15270 10 G 2,5 14 17,0 340,0 482,0
15245 3x1 17 8,6 60,0 80,0 15271 12 G 2,5 14 19,2 441,0 572,0
15246 4G1 17 9,4 71,0 100,0 15272 3G4 12 13,1 174,0 251,0
15247 4G1 17 9,4 71,0 100,0 15273 4G4 12 14,6 230,0 305,0
15248 5G1 17 10,4 88,0 130,0 15274 5G4 12 16,1 273,0 388,0
15249 10 G 1 17 14,9 150,0 232,0 15275 7G4 12 17,6 316,0 504,0
15250 12 G 1 17 14,5 184,0 260,0 15276 3G6 10 14,9 240,0 351,0
15251 18 G 1 17 17,9 260,0 382,0 15277 4G6 10 16,4 305,0 464,0
15252 20 G 1 17 19,0 317,0 440,0 15278 5G6 10 18,1 439,0 546,0
15253 25 G 1 17 21,7 349,0 540,0 15279 7G6 10 20,1 505,0 670,0
15254 2 x 1,5 16 9,0 63,0 88,0 15280 3 G 10 8 16,6 350,0 574,0
15255 3 G 1,5 16 9,7 80,0 100,0 15281 4 G 10 8 18,1 535,0 785,0
15256 3 x 1,5 16 9,7 80,0 100,0 15282 5 G 10 8 20,6 592,0 914,0
15257 4 G 1,5 16 10,5 97,0 125,0 15283 7 G 10 8 22,6 810,0 1308,0
15258 5 G 1,5 16 11,6 119,0 158,0

Dimensions and specifications may be changed without prior notice. (RA03)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

401
UL/CSA DATA CABLES

402
Cables according to international Approvals / Data Cables UL/CSA

Command Cable UL (LiYY) Style 2464/300 V, (80C)

Technical data Cable structure Properties


Special PVC command cable, approved to Tinned copper, fine wire conductors The materials used in manufacture are
UL-Style 2464, cores acc. to AWG 26-20, ASTM-B 174-95 class J-M, cadmium-free and contain no silicone
AWG 26-20 to UL-Style 1061/1729 AWG 18-16 ASTM-B 286 and free from substances harmful to
AWG 18-16 to UL-Style 1007/1569 Conductor make-up to: the wetting properties of lacquers
Temperature range 0,14 mm = 7x0,162 mm Tests
flexing -10C to +80C 0,23 mm = 7x0,202 mm PVC flame retardant according to
fixed installation -20C to +80C 0,34 mm = 7x0,254 mm UL VW-1, CSA FT1
Nominal voltage 300 V 0,56 mm = 7x0,32 mm Conditionally resistant to
Test voltage 1500 V 0,82 mm = 19x0,235 mm Oil
Breakdown voltage min. 3000 V 1,30 mm = 19x0,31 mm Solvents
Minimum bending radius Core insulation of special PVC class 43 Acids
fixed 7,5x cable respectively semirigid acc. to UL-Std.1581 Lyes
flexing 15x cable tab.50.182 and 50.183
Core identification to DIN 47100 or Note
international colour code AWG sizes are approximate equivalent
Cores stranded in layers with values. The actual cross-section is in mm.
optimal lay-length screened analogue type:
Outer sheath of special PVC class 43 command cable UL (LiYCY),
acc. to UL-Std.1581 tab.50.182 confer page 413
Sheath colour
black (international colour code)
grey (DIN 47100 / preferred type for stock)

Application
As a flexible connector and connecting cable, as control, signal and measuring line of machine tools, conveyor belts and plant construction, air
conditioning systems, in foundries and steel mills.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Part no. No.cores x AWG-No. Outer Cop. Weight Part no. Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath
colour
grey
Sheath
colour
black
cross-sec.
mm
app.
mm
weight app.
kg / km kg / km
Sheath
colour
grey
Sheath
colour
black
cross-sec.
mm
app.
mm
weight app.
kg / km kg / km N
83137 83045 2 x 0,14 26 3,6 3,6 13,0 83188 83389 6 x 0,56 20 6,1 29,0 65,0
83138 83046 3 x 0,14 26 3,8 4,0 15,0 83189 83390 10 x 0,56 20 7,6 48,2 102,0
83139 83047 4 x 0,14 26 4,0 5,4 18,0 83190 83391 12 x 0,56 20 7,8 58,2 120,0
83140 83048 6 x 0,14 26 4,6 8,1 25,0 83191 83392 16 x 0,56 20 8,7 77,3 152,0
83141 83049 10 x 0,14 26 5,6 13,4 38,0 83192 83393 18 x 0,56 20 9,3 87,0 168,0
83142 83050 12 x 0,14 26 5,8 16,2 46,0 83193 83394 24 x 0,56 20 10,9 116,3 224,0
83143 83055 16 x 0,14 26 6,3 21,5 56,0 83194 83395 27 x 0,56 20 11,2 129,8 260,0
83144 83056 18 x 0,14 26 6,6 34,4 62,0 83195 83396 30 x 0,56 20 11,8 144,6 300,0
83145 83057 24 x 0,14 26 7,5 32,4 82,0 83201 83397 2 x 0,82 18 6,1 15,2 50,0
83146 83058 27 x 0,14 26 7,6 36,3 97,0 83202 83398 3 x 0,82 18 6,4 23,2 62,0
83147 83059 30 x 0,14 26 8,0 40,4 110,0 83203 83399 4 x 0,82 18 6,9 31,3 72,0
83153 83130 2 x 0,23 24 3,8 4,6 16,0 83204 83474 6 x 0,82 18 8,1 47,0 100,0
83154 83131 3 x 0,23 24 4,0 7,1 19,0 83205 83475 10 x 0,82 18 10,4 78,2 180,0
83155 83132 4 x 0,23 24 4,3 9,4 23,0 83206 83476 12 x 0,82 18 10,9 94,0 182,0
83156 83133 6 x 0,23 24 4,9 14,2 32,0 83207 83477 16 x 0,82 18 12,2 125,1 240,0
83157 83134 10 x 0,23 24 6,0 23,8 55,0 83208 83478 18 x 0,82 18 13,0 141,1 270,0
83158 83135 12 x 0,23 24 6,2 28,5 60,0 83209 83479 24 x 0,82 18 15,2 188,2 370,0
83159 83136 16 x 0,23 24 6,8 38,1 75,0 83210 83480 27 x 0,82 18 15,8 212,0 400,0
83160 83371 18 x 0,23 24 7,1 43,1 82,0 83211 83481 30 x 0,82 18 16,3 235,6 470,0
83161 83372 24 x 0,23 24 8,1 59,7 116,0 83217 83482 2 x 1,3 16 6,6 24,4 70,0
83162 83373 27 x 0,23 24 8,4 64,7 140,0 83218 83483 3 x 1,3 16 7,0 37,1 90,0
83163 83374 30 x 0,23 24 8,9 71,9 150,0 83219 83484 4 x 1,3 16 7,6 49,4 110,0
83169 83375 2 x 0,34 22 4,1 6,5 25,0 83220 83491 6 x 1,3 16 9,2 74,2 160,0
83170 83376 3 x 0,34 22 4,3 9,8 30,0 83221 83492 10 x 1,3 16 11,8 124,0 250,0
83171 83377 4 x 0,34 22 4,6 13,0 45,0 83222 83493 12 x 1,3 16 12,2 149,0 300,0
83172 83378 6 x 0,34 22 5,4 19,6 60,0 83223 83494 16 x 1,3 16 13,7 198,7 400,0
83173 83379 10 x 0,34 22 6,6 32,5 80,0 83224 83495 18 x 1,3 16 14,6 224,0 450,0
83174 83380 12 x 0,34 22 6,8 39,1 105,0 83225 83496 24 x 1,3 16 17,0 298,4 650,0
83175 83381 16 x 0,34 22 7,5 52,0 130,0 83226 83497 27 x 1,3 16 17,6 336,0 680,0
83176 83382 18 x 0,34 22 8,1 59,0 140,0 83227 83498 30 x 1,3 16 18,6 373,6 750,0
83177 83383 24 x 0,34 22 9,4 79,0 190,0
83178 83384 27 x 0,34 22 9,7 88,0 207,0
83179 83385 30 x 0,34 22 10,2 97,8 225,0
83185 83386 2 x 0,56 20 4,6 9,8 30,0
83186 83387 3 x 0,56 20 4,8 14,6 33,0
83187 83388 4 x 0,56 20 5,2 19,4 41,0

Dimensions and specifications may be changed without prior notice. (RN02)

403
Cables according to international Approvals / Data Cables UL/CSA

Command Cable UL (LiYY) Style 2516, 600 V, 105C

Technical data Cable structure Properties


Special PVC command cable, approved to Tinned copper, fine wire conductors The materials used in manufacture are
UL-Style 2516 acc. to ASTM-B 174, class J-K cadmium-free and contain no silicone
Temperature range Conductor make-up to: and free from substances harmful to
flexing -10C to +105C 2,08 mm = 41x0,254 mm the wetting properties of lacquers
fixed installation -20C to +105C 3,20 mm = 65x0,254 mm Tests
Nominal voltage 600 V Core insulation of special PVC class 43 PVC flame retardant acc. to
Test voltage 2000 V acc. to UL-Std.1581 tab.50.182 (105C) UL VW-1, CSA FT1
Breakdown voltage min. 4000 V Core identification to DIN 47100 or Conditionally resistant to
Minimum bending radius international colour code Oil
fixed 7,5x cable Cores stranded in layers with Solvents
flexing 15x cable optimal lay-length Acids
Outer sheath of special PVC class 43 Lyes
acc. to UL-Std.1581 tab.50.182 (105C)
Sheath colour Note
black (international colour code) AWG sizes are approximate equivalent
grey (DIN 47100 / preferred type from values. The actual cross-section is in mm.
stock) screened analogue type:
command cable UL (LiYCY),
confer page 415

Application
As a flexible connector and connecting cable, as control, signal and measuring line of machine tools, conveyor belts and plant construction, air
conditioning systems, in foundries and steel mills.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Part no. No.cores x AWG-No. Outer Cop. Weight Part no. Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath Sheath cross-sec. app. weight app. Sheath Sheath cross-sec. app. weight app.
colour colour mm mm kg / km kg / km colour colour mm mm kg / km kg / km
grey black grey black
83233 83624 2 x 2,08 14 8,4 39,6 120,0 83245 83636 2 x 3,2 12 9,3 61,0 150,0
83234 83625 3 x 2,08 14 8,9 59,6 150,0 83246 83637 3 x 3,2 12 9,8 91,4 210,0
83235 83626 4 x 2,08 14 9,6 79,2 190,0 83247 83638 4 x 3,2 12 10,8 121,6 300,0
83236 83627 6 x 2,08 14 11,4 119,0 300,0 83248 83639 6 x 3,2 12 12,8 183,7 430,0
83237 83628 10 x 2,08 14 15,1 198,4 450,0 83249 83640 10 x 3,2 12 17,0 305,9 500,0
83238 83629 12 x 2,08 14 15,6 238,7 500,0 83250 83641 12 x 3,2 12 17,5 367,6 700,0
83239 83630 16 x 2,08 14 17,2 319,0 700,0 83251 83642 16 x 3,2 12 19,8 490,9 810,0
83240 83631 18 x 2,08 14 18,3 358,4 750,0 83252 83643 18 x 3,2 12 21,0 551,7 970,0
83241 83632 24 x 2,08 14 21,5 478,4 900,0 83253 83644 24 x 3,2 12 24,8 736,4 1200,0
83242 83633 27 x 2,08 14 22,7 538,1 1100,0
83243 83634 30 x 2,08 14 23,5 598,4 1150,0
83244 83635 36 x 2,08 14 25,4 717,2 1800,0

Dimensions and specifications may be changed without prior notice. (RN02)

Suitable accessories can be found in Chapter X.


Cable tie

404
Cables according to international Approvals / Data Cables UL/CSA

TRAYCONTROL 300 flexible, oil-resistant, NFPA 79 Edition 2012

Technical data Cable structure Properties


Flexible PVC data and control cable Tinned copper conductor, fine wire The materials used in manufacture are
Temperature range with AWG dimensions cadmium-free and contain no silicone
-25C to +105C Outer sheath of special PVC and free from substances harmful to
Nominal voltage 300 V (AWG 22 -AWG 16 with transparent the wetting properties of lacquers
Test voltage 2000 V nylon skin) Tests
Minimum bending radius Core identification to international self-extinguishing and flame retardant
flexing 6x cable colour code acc. to CSA FT4
Radiation resistance Cores stranded in layers with UL (AWG 22 - AWG 16):
up to 80x106 cJ/kg (up to 80 Mrad) optimal lay-lengths PLTC-ER, ITC-ER, Type CM, NFPA 79 2012,
Separator OIL RES I & II, Class I Div. 2,
Outer sheath of special PVC NEC Art. 501, 725, 760 & 800, AWM 2517
Sheath colour grey (RAL 7001) UL (AWG 24 - AWG 28):
With length marking in feet CM, AWM 2464, rated OIL RES I & II,
NEC Art. 725, 760 & 800, NFPA 79 2012
CSA:
CSA CMG FT4, AWM I/II A/B FT4

Note
Advantages
highly-flexible easy to install
Oil-resistant to OIL RES I & II
Available on request
PUR or TPE outer sheath
Sheath colour to suit customer
requirements

Application
HELUKABEL TRAYCONTROL 300 is a multi-core PVC data and control cable. Cross-sections with PLTC-ER and ITC-ER approval suitable for open,
unprotected installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as connecting and
joining cables and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates installation inside and
outside of machines and switch cabinets. Applications: tool machines, control panels, control and instrumentation technology, production automation, N
cable ducts, renewable energies.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62625 0,093 2 x 28 3,9 1,8 12,0 62655 0,241 15 x 24 7,4 34,7 69,0
62626 0,093 3 x 28 4,2 2,7 18,0 62656 0,241 20 x 24 8,4 46,3 86,0
62627 0,093 4 x 28 4,4 3,6 21,0 62657 0,241 25 x 24 9,3 57,9 103,0
62628 0,093 6 x 28 4,9 5,4 27,0 62658 0,241 30 x 24 9,6 69,4 131,0
62629 0,093 8 x 28 5,2 7,2 30,0 62659 0,241 40 x 24 11,2 92,6 173,0
62630 0,093 10 x 28 5,8 8,9 30,0 62660 0,241 50 x 24 12,4 115,7 219,0
62631 0,093 15 x 28 6,4 13,4 43,0 62661 0,382 2 x 22 6,1 7,4 22,0
62632 0,093 20 x 28 7,0 17,9 54,0 62662 0,382 3 x 22 6,7 11,0 28,0
62633 0,093 25 x 28 8,0 22,3 63,0 62663 0,382 4 x 22 7,2 14,7 32,0
62634 0,093 30 x 28 8,4 26,8 73,0 62664 0,382 6 x 22 7,8 22,0 46,0
62635 0,093 40 x 28 9,1 35,7 89,0 62665 0,382 8 x 22 8,8 29,4 54,0
62636 0,093 50 x 28 10,1 44,7 109,0 62666 0,382 10 x 22 9,1 36,7 66,0
62637 0,154 2 x 26 4,2 3,0 18,0 62667 0,382 15 x 22 9,7 55,0 90,0
62638 0,154 3 x 26 4,3 4,4 21,0 62668 0,382 20 x 22 10,5 73,4 115,0
62639 0,154 4 x 26 4,5 5,9 24,0 62669 0,382 25 x 22 11,9 91,7 141,0
62640 0,154 6 x 26 5,2 8,9 30,0 62670 0,382 30 x 22 12,3 110,0 176,0
62641 0,154 8 x 26 5,5 11,8 34,0 62671 0,382 40 x 22 13,5 146,7 234,0
62642 0,154 10 x 26 6,2 14,8 42,0 62672 0,382 50 x 22 14,9 183,4 293,0
62643 0,154 15 x 26 6,8 22,2 52,0 62673 0,616 2 x 20 6,9 11,9 57,0
62644 0,154 20 x 26 7,7 29,6 67,0 62674 0,616 3 x 20 7,2 17,8 60,0
62645 0,154 25 x 26 8,5 37,0 80,0 62675 0,616 4 x 20 7,8 23,7 73,0
62646 0,154 30 x 26 8,8 44,4 92,0 62676 0,616 6 x 20 9,0 35,5 97,0
62647 0,154 40 x 26 9,6 59,1 116,0 62677 0,616 8 x 20 9,6 47,4 133,0
62648 0,154 50 x 26 10,8 73,9 145,0 62678 0,616 10 x 20 10,8 59,2 143,0
62649 0,241 2 x 24 4,4 4,7 19,0 62679 0,616 15 x 20 12,4 88,8 177,0
62650 0,241 3 x 24 4,6 7,0 22,0 62680 0,616 20 x 20 14,5 118,3 261,0
62651 0,241 4 x 24 4,9 9,3 27,0 62681 0,616 25 x 20 15,3 147,9 353,0
62652 0,241 6 x 24 5,6 13,9 33,0 62682 0,616 30 x 20 15,9 177,5 419,0
62653 0,241 8 x 24 5,9 18,5 42,0 62683 0,616 40 x 20 18,1 236,6 562,0
62654 0,241 10 x 24 6,6 23,2 49,0 62684 0,616 50 x 20 20,1 295,7 699,0

Continuation

405
Cables according to international Approvals / Data Cables UL/CSA

TRAYCONTROL 300 flexible, oil-resistant, NFPA 79 Edition 2012


Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62685 0,963 2 x 18 7,4 18,5 61,0 62697 1,31 2 x 16 7,5 25,2 83,0
62686 0,963 3 x 18 7,6 27,8 64,0 62698 1,31 3 x 16 8,4 37,8 91,0
62687 0,963 4 x 18 8,3 37,0 77,0 62699 1,31 4 x 16 8,8 50,3 109,0
62688 0,963 6 x 18 9,5 55,5 101,0 62700 1,31 6 x 16 10,1 75,5 162,0
62689 0,963 8 x 18 10,1 74,0 142,0 62702 1,31 8 x 16 11,4 100,7 243,0
62690 0,963 10 x 18 12,1 92,5 195,0 62703 1,31 10 x 16 13,0 125,8 267,0
62691 0,963 15 x 18 13,6 138,7 247,0 62704 1,31 15 x 16 14,7 188,7 364,0
62692 0,963 20 x 18 14,9 184,9 328,0 62705 1,31 20 x 16 16,1 251,6 493,0
62693 0,963 25 x 18 17,6 231,2 407,0 62706 1,31 25 x 16 18,3 314,5 608,0
62694 0,963 30 x 18 17,7 277,4 539,0 62707 1,31 30 x 16 19,2 377,3 729,0
62695 0,963 40 x 18 19,5 369,8 717,0 62708 1,31 40 x 16 21,3 503,1 967,0
62696 0,963 50 x 18 21,8 462,3 894,0 62709 1,31 50 x 16 23,9 628,8 1214,0

Dimensions and specifications may be changed without prior notice. (RN02)

Suitable accessories can be found in Chapter X.


Cable tie

406
Cables according to international Approvals / Data Cables UL/CSA

Command Cable UL (LiYY-TP) Style 2464, 300 V, 80C

Technical data Cable structure Properties


Special PVC command cable, approved Tinned copper, fine wire conductors acc. to The materials used in manufacture are
to UL-Style 2464, cores ASTM-B 174-95 class J-M cadmium-free and contain no silicone
acc. to UL-Style 1061/1729 conductor make-up to and free from substances harmful to
Temperature range 0,14 mm = 7x0,162 mm the wetting properties of lacquers
flexing -10C to +80C 0,23 mm = 7x0,202 mm Tests
fixed installation -20C to +80C 0,34 mm = 7x0,254 mm PVC flame retardant acc. to
Nominal voltage 300 V 0,56 mm = 7x0,32 mm UL VW-1, CSA FT1
Test voltage 1500 V Core insulation of special PVC Conditionally resistant to
Breakdown voltage min. 3000 V class 43 respectively semirigid acc. to Oil
Insulation resistance UL-Std.1581 tab.50.182 and 50183 Solvents
min. 100 MOhm x km Core identification (pair) to DIN 47100, Acids
Minimum bending radius with colour repetition from pair no. 23 or Lyes
fixed 7,5x cable international colour code
flexing 15x cable Cores stranded in pairs with optimal Note
lay-length AWG sizes are approximate equivalent
Pairs stranded in layers with optimal values. The actual cross-section is in mm.
lay-length screened analogue type:
Seperator-foil command cable UL (LiYCY-TP),
Outer sheath of special PVC confer page 418
class 43 acc. to UL-Std.1581 tab.50.182
Sheath colour
black (international colour code)
grey (DIN 47100 - preferred type)

Application
Twisted pair control cable for use in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning as well
as in the steel producing industries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x


Sheath cross-sec.
AWG-No. Outer Cop.
app. mm weight
Weight
app. kg / km
Part no. No.pairs x
Sheath cross-sec.
AWG-No. Outer Cop.
app. mm weight
Weight
app. kg / km N
colour mm kg / km colour mm kg / km
grey black
83904 1 x 2 x 0,14 26 3,6 2,7 20,0 65214 1 x 2 x 0,14 26 3,6 2,7 20,0
83905 2 x 2 x 0,14 26 5,1 5,4 24,0 65215 2 x 2 x 0,14 26 5,1 5,4 24,0
83906 3 x 2 x 0,14 26 5,3 8,1 30,0 65216 3 x 2 x 0,14 26 5,3 8,1 30,0
83907 4 x 2 x 0,14 26 5,8 10,8 38,0 65217 4 x 2 x 0,14 26 5,8 10,8 38,0
83908 5 x 2 x 0,14 26 6,2 13,6 44,0 65218 5 x 2 x 0,14 26 6,2 13,6 44,0
83909 6 x 2 x 0,14 26 6,8 16,2 51,0 65219 6 x 2 x 0,14 26 6,8 16,2 51,0
83910 7 x 2 x 0,14 26 6,8 19,0 57,0 65220 7 x 2 x 0,14 26 6,8 19,0 57,0
83911 8 x 2 x 0,14 26 7,3 21,7 64,0 65221 8 x 2 x 0,14 26 7,3 21,7 64,0
83912 10 x 2 x 0,14 26 7,4 26,7 76,0 65222 10 x 2 x 0,14 26 7,4 26,7 76,0
83913 12 x 2 x 0,14 26 9,1 32,6 93,0 65223 12 x 2 x 0,14 26 9,1 32,6 93,0
83914 14 x 2 x 0,14 26 9,8 37,4 103,0 65224 14 x 2 x 0,14 26 9,8 37,4 103,0
83915 15 x 2 x 0,14 26 10,6 40,7 109,0 65225 15 x 2 x 0,14 26 10,6 40,7 109,0
83916 16 x 2 x 0,14 26 10,6 43,4 112,0 65226 16 x 2 x 0,14 26 10,6 43,4 112,0
83917 18 x 2 x 0,14 26 11,1 48,5 119,0 65227 18 x 2 x 0,14 26 11,1 48,5 119,0
83918 20 x 2 x 0,14 26 11,9 54,2 130,0 65228 20 x 2 x 0,14 26 11,9 54,2 130,0
83919 22 x 2 x 0,14 26 12,4 59,3 150,0 65229 22 x 2 x 0,14 26 12,4 59,3 150,0
83920 24 x 2 x 0,14 26 13,1 64,7 169,0 65230 24 x 2 x 0,14 26 13,1 64,7 169,0
83921 25 x 2 x 0,14 26 13,4 67,2 178,0 65231 25 x 2 x 0,14 26 13,4 67,2 178,0
83922 1 x 2 x 0,23 24 3,8 4,8 32,0 65232 1 x 2 x 0,23 24 3,8 4,8 32,0
83923 2 x 2 x 0,23 24 5,3 9,7 36,0 65233 2 x 2 x 0,23 24 5,3 9,7 36,0
83924 3 x 2 x 0,23 24 5,7 14,7 48,0 65234 3 x 2 x 0,23 24 5,7 14,7 48,0
83925 4 x 2 x 0,23 24 6,2 19,6 56,0 65235 4 x 2 x 0,23 24 2,0 19,6 56,0
83926 5 x 2 x 0,23 24 6,6 24,6 71,0 65236 5 x 2 x 0,23 24 6,0 24,6 56,0
83927 6 x 2 x 0,23 24 7,2 29,3 80,0 65237 6 x 2 x 0,23 24 7,2 29,3 80,0
83928 7 x 2 x 0,23 24 7,2 34,1 89,0 65238 7 x 2 x 0,23 24 7,2 34,1 89,0
83929 8 x 2 x 0,23 24 7,8 39,1 98,0 65239 8 x 2 x 0,23 24 7,8 39,1 98,0
83930 10 x 2 x 0,23 24 9,2 48,9 111,0 65240 10 x 2 x 0,23 24 9,2 48,9 111,0
83931 12 x 2 x 0,23 24 9,7 59,4 135,0 65241 12 x 2 x 0,23 24 9,7 59,4 135,0
83932 14 x 2 x 0,23 24 10,2 68,7 160,0 65242 14 x 2 x 0,23 24 10,2 68,7 160,0

Continuation

407
Cables according to international Approvals / Data Cables UL/CSA

Command Cable UL (LiYY-TP) Style 2464, 300 V, 80C


Part no. No.pairs x AWG-No. Outer Cop. Weight Part no. No.pairs x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. kg / km Sheath cross-sec. app. mm weight app. kg / km
colour mm kg / km colour mm kg / km
grey black
83933 15 x 2 x 0,23 24 10,9 73,7 171,0 65243 15 x 2 x 0,23 24 10,9 73,7 171,0
83934 16 x 2 x 0,23 24 10,9 79,1 185,0 65244 16 x 2 x 0,23 24 10,9 79,1 185,0
83935 18 x 2 x 0,23 24 11,5 88,9 209,0 65245 18 x 2 x 0,23 24 11,5 88,9 209,0
83936 20 x 2 x 0,23 24 12,2 98,4 230,0 65246 20 x 2 x 0,23 24 12,2 98,4 230,0
83937 22 x 2 x 0,23 24 13,0 108,6 248,0 65247 22 x 2 x 0,23 24 13,0 108,6 248,0
83938 24 x 2 x 0,23 24 13,7 117,9 279,0 65248 24 x 2 x 0,23 24 13,7 117,9 279,0
83939 25 x 2 x 0,23 24 14,2 123,5 292,0 65249 25 x 2 x 0,23 24 14,2 123,5 292,0
83940 1 x 2 x 0,34 22 4,2 6,5 38,0 65250 1 x 2 x 0,34 22 4,2 6,5 38,0
83941 2 x 2 x 0,34 22 5,9 13,0 44,0 65251 2 x 2 x 0,34 22 5,9 13,0 44,0
83942 3 x 2 x 0,34 22 6,3 19,5 60,0 65252 3 x 2 x 0,34 22 6,3 19,5 60,0
83943 4 x 2 x 0,34 22 7,0 26,1 79,0 65253 4 x 2 x 0,34 22 7,0 26,1 79,0
83944 5 x 2 x 0,34 22 7,6 32,6 92,0 65254 5 x 2 x 0,34 22 7,6 32,6 92,0
83945 6 x 2 x 0,34 22 8,2 39,2 119,0 65255 6 x 2 x 0,34 22 8,2 39,2 119,0
83946 7 x 2 x 0,34 22 8,2 45,7 128,0 65256 7 x 2 x 0,34 22 8,2 45,7 128,0
83947 8 x 2 x 0,34 22 9,0 52,3 139,0 65257 8 x 2 x 0,34 22 9,0 52,3 139,0
83948 10 x 2 x 0,34 22 10,7 65,3 171,0 65258 10 x 2 x 0,34 22 10,7 65,3 171,0
83949 12 x 2 x 0,34 22 11,3 78,4 194,0 65259 12 x 2 x 0,34 22 11,3 78,4 194,0
83950 14 x 2 x 0,34 22 12,1 91,5 222,0 65260 14 x 2 x 0,34 22 12,1 91,5 222,0
83951 15 x 2 x 0,34 22 12,7 97,8 231,0 65261 15 x 2 x 0,34 22 12,7 97,8 231,0
83952 16 x 2 x 0,34 22 12,7 104,6 240,0 65262 16 x 2 x 0,34 22 12,7 104,6 240,0
83953 18 x 2 x 0,34 22 13,6 117,8 264,0 65263 18 x 2 x 0,34 22 13,6 117,8 264,0
83954 20 x 2 x 0,34 22 14,4 130,7 291,0 65264 20 x 2 x 0,34 22 14,4 130,7 291,0
83955 22 x 2 x 0,34 22 15,1 143,6 300,0 65265 22 x 2 x 0,34 22 15,1 143,6 300,0
83956 24 x 2 x 0,34 22 16,2 156,8 359,0 65266 24 x 2 x 0,34 22 16,2 156,8 359,0
83957 25 x 2 x 0,34 22 16,7 163,3 381,0 65267 25 x 2 x 0,34 22 16,7 163,3 381,0
83958 1 x 2 x 0,56 20 4,6 10,8 60,0 65268 1 x 2 x 0,56 20 4,6 10,8 60,0
83959 2 x 2 x 0,56 20 6,5 21,5 80,0 65269 2 x 2 x 0,56 20 6,5 21,5 80,0
83960 3 x 2 x 0,56 20 7,1 32,3 94,0 65270 3 x 2 x 0,56 20 7,1 32,3 94,0
83961 4 x 2 x 0,56 20 7,8 43,1 104,0 65271 4 x 2 x 0,56 20 7,8 43,1 104,0
83962 5 x 2 x 0,56 20 8,6 53,8 130,0 65272 5 x 2 x 0,56 20 8,6 53,8 130,0
83963 6 x 2 x 0,56 20 9,6 64,6 151,0 65273 6 x 2 x 0,56 20 9,6 64,6 151,0
83964 7 x 2 x 0,56 20 9,6 75,3 174,0 65274 7 x 2 x 0,56 20 9,6 75,3 174,0
83965 8 x 2 x 0,56 20 12,2 86,1 262,0 65275 8 x 2 x 0,56 20 12,1 86,1 262,0
83966 10 x 2 x 0,56 20 12,5 107,7 298,0 65276 10 x 2 x 0,56 20 12,5 107,7 298,0
83967 12 x 2 x 0,56 20 13,1 129,1 302,0 65277 12 x 2 x 0,56 20 13,1 129,1 302,0
83968 14 x 2 x 0,56 20 13,8 150,6 327,0 65278 14 x 2 x 0,56 20 13,8 150,6 327,0
83969 15 x 2 x 0,56 20 14,7 161,3 370,0 65279 15 x 2 x 0,56 20 14,7 161,3 370,0
83970 16 x 2 x 0,56 20 14,7 172,1 402,0 65280 16 x 2 x 0,56 20 14,7 172,1 402,0
83971 18 x 2 x 0,56 20 15,7 193,6 480,0 65281 18 x 2 x 0,56 20 15,7 193,6 480,0
83972 20 x 2 x 0,56 20 16,7 215,1 551,0 65282 20 x 2 x 0,56 20 16,7 215,1 551,0
83973 22 x 2 x 0,56 20 17,2 236,6 621,0 65283 22 x 2 x 0,56 20 17,2 236,6 621,0
83974 24 x 2 x 0,56 20 18,6 258,0 703,0 65284 24 x 2 x 0,56 20 18,6 258,0 703,0
83975 25 x 2 x 0,56 20 19,2 268,9 721,0 65285 25 x 2 x 0,56 20 19,2 268,9 721,0

Dimensions and specifications may be changed without prior notice. (RN02)

Suitable accessories can be found in Chapter X.


Cable tie

408
Cables according to international Approvals / Data Cables UL/CSA

TRAYCONTROL 300 TP twisted pair, flexible, oil-resistant,


NFPA 79 Edition 2012

Technical data Cable structure Properties


Flexible PVC data and control cable Tinned copper conductor, fine wire Self-extinguishing and flame retardant in
Temperature range stranded, with AWG measures acc. to CSA FT4
-25C to +105C Core insulation of special PVC The materials used in manufacture are free
Nominal voltage 300 V (AWG 22 - AWG 18 with transparent of silicone, cadmium and substances that
Test voltage 2000 V nylon skin) impair paint wetting
Minimum bending radius Core identification (pair) acc. to Tests
flexing 6x cable international colour code UL (AWG 22 - AWG 18): PLTC-ER, ITC-ER,
Radiation resistance Cores stranded in pairs with optimal Type CM, NFPA 79 2012,
up to 80x106 cJ/kg (up to 80 Mrad) lay-length OIL RES I & II, Class I Div. 2,
Pairs stranded in layers with optimal NEC Art. 501, 725, 760 & 800, AWM 2517
lay-length UL (AWG 24 - AWG 26): CM, AWM
Separator 2464, rated OIL RES I & II,
Outer sheath of special PVC NEC Art. 725, 760 & 800, NFPA 79 2012
Sheath colour - grey (RAL 7001) CSA: CSA CMG FT4, AWM I/II A/B FT4
with length marking in feet
Note
Advantages
Highly-flexible, easy to install
Oil-resistant to OIL RES I & II
Available on request
PUR or TPE outer sheath
Sheath colour to suit customer
requirement

Application
HELUKABEL TRAYCONTROL 300 TP is a twisteded pair data and control cable. Cross-sections with PLTC-ER and ITC-ER approval for open, unprotected
installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as connecting and joining cables
and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates installation inside and outside of machines
and switch cabinets. Applications: tool machines, control panels, measuring devices, production automation, cable ducts, renewable energies.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
N
Part no. Cross- No.pairs x Outer Cop. Weight Part no. Cross- No.pairs x Outer Cop. Weight
section mm No.cores app. mm weight app. section mm No.cores app. mm weight app.
x kg / km kg / km x kg / km kg / km
AWG-no. AWG-no.
62794 0,154 1 x 2 x 26 3,6 3,0 20,0 61951 0,241 16 x 2 x 24 12,1 79,0 185,0
62795 0,154 2 x 2 x 26 5,1 5,0 24,0 61952 0,241 18 x 2 x 24 13,5 89,0 209,0
62796 0,154 3 x 2 x 26 5,3 8,0 30,0 61953 0,241 20 x 2 x 24 14,4 98,0 230,0
62797 0,154 4 x 2 x 26 5,8 11,0 38,0 61954 0,241 22 x 2 x 24 15,3 109,0 248,0
62798 0,154 5 x 2 x 26 6,2 14,0 44,0 61955 0,241 24 x 2 x 24 16,1 118,0 279,0
62799 0,154 6 x 2 x 26 6,8 16,0 51,0 61956 0,241 25 x 2 x 24 16,7 124,0 292,0
62800 0,154 7 x 2 x 26 6,9 19,0 57,0 61957 0,382 1 x 2 x 22 4,2 7,0 38,0
61928 0,154 8 x 2 x 26 7,3 22,0 64,0 61958 0,382 2 x 2 x 22 6,4 13,0 44,0
61929 0,154 10 x 2 x 26 7,4 27,0 76,0 61959 0,382 3 x 2 x 22 6,8 20,0 60,0
61930 0,154 12 x 2 x 26 9,1 33,0 93,0 61960 0,382 4 x 2 x 22 9,2 29,3 79,0
61931 0,154 14 x 2 x 26 9,8 38,0 103,0 61961 0,382 5 x 2 x 22 8,2 33,0 92,0
61932 0,154 15 x 2 x 26 10,6 41,0 109,0 61962 0,382 6 x 2 x 22 8,9 39,0 119,0
61933 0,154 16 x 2 x 26 10,7 43,0 112,0 61963 0,382 7 x 2 x 22 9,0 46,0 128,0
61934 0,154 18 x 2 x 26 11,1 49,0 119,0 61964 0,382 8 x 2 x 22 9,9 52,0 139,0
61935 0,154 20 x 2 x 26 11,9 54,0 130,0 61965 0,382 10 x 2 x 22 11,7 65,0 171,0
61936 0,154 22 x 2 x 26 12,4 59,0 150,0 61966 0,382 12 x 2 x 22 12,4 78,0 194,0
61937 0,154 24 x 2 x 26 13,1 65,0 169,0 61967 0,382 14 x 2 x 22 13,0 92,0 222,0
61938 0,154 25 x 2 x 26 13,4 67,0 178,0 61968 0,382 15 x 2 x 22 13,2 98,0 231,0
61939 0,241 1 x 2 x 24 3,9 5,0 32,0 61969 0,382 16 x 2 x 22 13,3 105,0 240,0
61940 0,241 2 x 2 x 24 5,9 10,0 36,0 61970 0,382 18 x 2 x 22 14,2 118,0 264,0
61941 0,241 3 x 2 x 24 6,2 15,0 48,0 61971 0,382 20 x 2 x 22 15,1 131,0 291,0
61942 0,241 4 x 2 x 24 6,5 20,0 56,0 61972 0,382 22 x 2 x 22 15,8 144,0 300,0
61943 0,241 5 x 2 x 24 7,2 25,0 71,0 61973 0,382 24 x 2 x 22 17,0 157,0 359,0
61944 0,241 6 x 2 x 24 8,1 29,0 80,0 61974 0,382 25 x 2 x 22 17,5 163,0 381,0
61945 0,241 7 x 2 x 24 8,2 34,0 89,0 61975 0,616 1 x 2 x 20 5,2 11,0 60,0
61946 0,241 8 x 2 x 24 8,9 39,0 98,0 61976 0,616 2 x 2 x 20 8,8 22,0 80,0
61947 0,241 10 x 2 x 24 10,5 49,0 111,0 61977 0,616 3 x 2 x 20 9,3 32,0 94,0
61948 0,241 12 x 2 x 26 11,0 59,0 135,0 61978 0,616 4 x 2 x 20 10,2 43,0 104,0
61949 0,241 14 x 2 x 24 11,6 69,0 160,0 61979 0,616 5 x 2 x 20 11,3 54,0 130,0
61950 0,241 15 x 2 x 24 12,0 74,0 171,0 61980 0,616 6 x 2 x 20 12,5 65,0 151,0

Continuation

409
Cables according to international Approvals / Data Cables UL/CSA

TRAYCONTROL 300 TP twisted pair, flexible, oil-resistant,


NFPA 79 Edition 2012
Part no. Cross- No.pairs x Outer Cop. Weight Part no. Cross- No.pairs x Outer Cop. Weight
section mm No.cores app. mm weight app. section mm No.cores app. mm weight app.
x kg / km kg / km x kg / km kg / km
AWG-no. AWG-no.
61981 0,616 7 x 2 x 20 12,6 75,0 174,0 61990 0,616 22 x 2 x 20 21,8 237,0 621,0
61982 0,616 8 x 2 x 20 15,9 86,0 262,0 61991 0,616 24 x 2 x 20 23,5 258,0 703,0
61983 0,616 10 x 2 x 20 16,4 108,0 298,0 61992 0,616 25 x 2 x 20 24,3 269,0 721,0
61984 0,616 12 x 2 x 20 17,2 129,0 302,0 61993 0,963 1 x 2 x 18 5,6 18,0 61,0
61985 0,616 14 x 2 x 20 18,1 151,0 327,0 61994 0,963 2 x 2 x 18 9,6 36,0 77,0
61986 0,616 15 x 2 x 20 18,5 161,0 370,0 61995 0,963 3 x 2 x 18 10,6 54,0 103,0
61987 0,616 16 x 2 x 20 18,6 172,0 402,0 61996 0,963 6 x 2 x 18 13,7 107,0 216,0
61988 0,616 18 x 2 x 20 19,9 194,0 480,0 61997 0,963 9 x 2 x 18 16,4 162,0 328,0
61989 0,616 20 x 2 x 20 21,1 215,0 551,0 61998 0,963 15 x 2 x 18 20,4 271,0 542,0

Dimensions and specifications may be changed without prior notice. (RN02)

Suitable accessories can be found in Chapter X.


Cable tie

410
Cables according to international Approvals / Data Cables UL/CSA

SENSORFLEX / VERTEILERFLEX
two-approvals sensor actuator and distributor cables PVC, PUR, PVC/PUR

Technical data Cable structure Properties


Special PVC or PUR sheath acc. to PVC cables PVC cables
- UL-Style 2464 for PVC Bare copper-conductor, to Extensively oil resistant;
- UL-Style 20233 for PUR DIN VDE 0295 cl.5, fine-wire, Chemical Resistance (see table
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Technical Informations)
flexing -5C to +80C Core insulation of PVC PVC self-extinguishing and flame retardant
fixed installation -30C to +80C Core identification see table below acc. to DIN VDE 0482-332-1-2,
Nominal voltage U0/U 300/500 V Outer sheath of special PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
Test voltage PUR cables DIN VDE 0472 part 804 test method B)
up to 0,25 mm 1200 V Bare copper-conductor, to PUR cables
from 0,34 mm 2000 V DIN VDE 0295 cl.6, extra fine-wire, Low adhesion, extremely abrasion resistant,
Minimum bending radius BS 6360 cl.6, IEC 60228 cl.6 resistant to hydrolysis and microbial attack
SENSORFLEX two-approvals PVC Core insulation of PVC Special feature
15x cable Core identification see table below The cables with the highly flexible
SENSORFLEX two-approvals PUR Outer sheath of PUR stranded conductor cl.6, are
7,5x cable Part no. 79907, 75642, 79850 suitable for drag chain applications
Construction as per SENSORFLEX The types with PVC/PUR sheath
two-approvals material have a PVC inner sheath,
Core insulation of polypropylene with a PUR sheath applied over it
by means of coextrusion

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
For decentralised installation and control technology. These cables are used in connector systems for sensors and actuators. In combination with
injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element between the periphery and the PLC
in production systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also
in the entire manufacturing industry. While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now
N
field bus technology has made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. Moving the
I/O points to the system periphery enables significant reductions in installation costs.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
SENSORFLEX 2-APPROVALS
Part no. Cable structure AWG-No.
Sheath colour No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** app. mm weight app.
mm kg / km kg / km
78284 GY RAL 7001 3 x 0,25 PUR BN, BU, BK X 4,4 7,2 18,0 24
79907 GY RAL 7001 4 x 0,25 PUR BN, BU, BK, WH X 4,7 9,6 18,0 24
78286 GY RAL 7001 6 x 0,25 PVC BN, BU, BK, WH, GY, PK X 5,2 14,4 36,0 24
76345 GY RAL 7001 3 x 0,34 PVC BN, BU, BK X 4,9 9,8 30,0 22
76347 GY RAL 7001 4 x 0,34 PVC BN, BU, BK, WH X 5,2 13,1 43,0 22
76348 GY RAL 7001 5 G 0,34 PVC/PUR BN, BU, BK, WH, GN-YE X 5,9 16,4 54,0 22
76349 GY RAL 7001 5 G 0,34 PVC/PUR BN, BU, BK, WH, GN-YE X 5,9 16,4 54,0 22
78287 GY RAL 7001 5 G 0,34 PVC/PUR BK with number, GN-YE X 5,9 16,4 54,0 22
79850 GY RAL 7001 5 G 0,34 PUR BN, BU, BK, WH, GN-YE X 5,9 16,4 54,0 22
73571 GY RAL 7001 3 G 0,75 PVC BK with number, GN-YE X 6,7 21,6 58,0 18
75642 BK RAL 9005 3 G 0,75 PUR BK with number, GN-YE X 5,9 21,6 58,0 18
76351 GY RAL 7001 3 G 0,75 PVC BN, BU, GN-YE X 6,7 28,8 88,0 18
78288 GY RAL 7001 3 G 0,75 PUR BK with number, GN-YE X 5,9 21,6 58,0 18

Continuation

411
Cables according to international Approvals / Data Cables UL/CSA

SENSORFLEX / VERTEILERFLEX
two-approvals sensor actuator and distributor cables PVC, PUR, PVC/PUR
SENSORFLEX 2-APPROVALS
Part no. Cable structure AWG-No.
Sheath colour No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** app. mm weight app.
mm kg / km kg / km
74551 GY RAL 7001 4 G 0,75 PUR BK with number, GN-YE X 6,9 29,0 66,0 18
78289 GY RAL 7001 4 G 0,75 PVC/PUR BK with number, GN-YE X 7,0 29,0 66,0 18
77352 BK RAL 9005 2x1 PVC SW mit Ziffer 1-2 X 7,2 19,2 56,0 17
78290 GY RAL 7001 2x1 PVC SW mit Ziffer 1-2 X 7,2 19,2 56,0 17
76350 GY RAL 7001 11 G 1 PVC/PUR BK with number 1-8, BN, BU, GN-YE X 12,0 105,6 225,0 17
78291 GY RAL 7001 2 x 1,5 PVC BN, BU X 6,8 29,0 75,0 16
73587 GY RAL 7001 3 G 1,5 PVC BN, BU, GN-YE X 6,9 44,0 94,0 16

Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

412
Cables according to international Approvals / Data Cables UL/CSA

Command Cable UL (LiYCY) Style 2464, 300 V, 80C,


EMC-preferred type

Technical data Cable structure Properties


Special PVC command cable, approved Tinned copper, fine wire conductors The materials used in manufacture are
to UL-Style 2464, cores AWG 26-20 gem. ASTM-B 174-95 class J-M, cadmium-free and contain no silicone
acc. to UL-Style 1061/1729 for AWG 26-20, AWG 18-16 gem. ASTM-B 286 and free from substances harmful to
UL-Style 1007/1569 for AWG 18-16 conductor make-up to the wetting properties of lacquers
Temperature range 0,14 mm = 7x0,162 mm Tests
flexing -10C to +80C 0,23 mm = 7x0,202 mm PVC flame retardant acc. to
fixed installation -20C to +80C 0,34 mm = 7x0,254 mm UL VW-1, CSA FT1
Nominal voltage 300 V 0,56 mm = 7x0,32 mm Conditionally resistant to
Test voltage 1500 V 0,82 mm = 19x0,235 mm Oil
Breakdown voltage min. 3000 V 1,30 mm = 19x0,31 mm Solvents
Minimum bending radius Core insulation of special PVC Acids
fixed 7,5x cable class 43 respectively semirigid acc. to Lyes
flexing 15x cable UL-Std. 1581 tab.50.182 and 50.183
Coupling resistance Colour coded to DIN 47100 or international Note
max. 250 Ohm/km colour code AWG sizes are approximate equivalent
Cores stranded in layers with values. The actual cross-section is in mm.
optimal lay-length non-screened analogue types:
Seperator-foil command cable UL (LiYY),
Drain wire confer page 403
Tinned copper wire braiding, approx. 85%
coverage
Outer sheath of PVC class 43 acc. to
UL-Std.1581 tab.50.182
Sheath colour
black (international colour code)
grey (DIN 47100 - preferred type from
stock)

Application
As a flexible interconnecting cable for electronics, control and command technology, as well as in measurement, signal, and pulse technology. Fast N
and inexpensive contacting by cutting and clamping technology.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Part no. No.cores x AWG-No. Outer Cop. Weight Part no. Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath Sheath cross-sec. app. weight app. Sheath Sheath cross-sec. app. weight app.
colour colour mm mm kg / km kg / km colour colour mm mm kg / km kg / km
grey black grey black
83254 83976 2 x 0,14 26 3,9 12,6 20,0 83270 83987 2 x 0,23 24 4,3 16,1 20,0
83255 83977 3 x 0,14 26 4,2 13,7 25,0 83271 83988 3 x 0,23 24 4,5 18,9 25,0
83256 83978 4 x 0,14 26 4,4 14,9 28,0 83272 83989 4 x 0,23 24 4,8 23,0 30,0
83257 83979 6 x 0,14 26 5,0 18,9 30,0 83273 83990 6 x 0,23 24 5,4 32,8 40,0
83258 83980 10 x 0,14 26 6,1 29,5 50,0 83274 83991 10 x 0,23 24 6,5 50,9 60,0
83259 83981 12 x 0,14 26 6,3 31,4 53,0 83275 83992 12 x 0,23 24 6,7 59,1 70,0
83260 83982 16 x 0,14 26 6,8 43,9 60,0 83276 83993 16 x 0,23 24 7,4 68,4 90,0
83261 83983 18 x 0,14 26 7,1 52,1 70,0 83277 83994 18 x 0,23 24 7,7 79,5 123,0
83262 83984 24 x 0,14 26 8,0 62,8 100,0 83278 83995 24 x 0,23 24 8,8 97,3 131,0
83263 83985 27 x 0,14 26 8,4 66,3 105,0 83279 83996 27 x 0,23 24 9,0 122,0 160,0
83264 83986 30 x 0,14 26 8,6 70,4 110,0 83280 83997 30 x 0,23 24 9,3 132,0 170,0

Continuation

413
Cables according to international Approvals / Data Cables UL/CSA

Command Cable UL (LiYCY) Style 2464, 300 V, 80C,


EMC-preferred type
Part no. Part no. No.cores x AWG-No. Outer Cop. Weight Part no. Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath Sheath cross-sec. app. weight app. Sheath Sheath cross-sec. app. weight app.
colour colour mm mm kg / km kg / km colour colour mm mm kg / km kg / km
grey black grey black
83286 65044 2 x 0,34 22 4,6 18,1 40,0 83318 65066 2 x 0,82 18 6,5 39,1 60,0
83287 65045 3 x 0,34 22 4,8 22,2 50,0 83319 65067 3 x 0,82 18 6,8 50,0 75,0
83288 65046 4 x 0,34 22 5,1 28,7 60,0 83320 65068 4 x 0,82 18 7,4 59,1 90,0
83289 65047 6 x 0,34 22 6,0 45,4 80,0 83321 65069 6 x 0,82 18 8,8 89,1 125,0
83290 65048 10 x 0,34 22 7,3 66,1 130,0 83322 65070 10 x 0,82 18 10,9 141,4 180,0
83291 65049 12 x 0,34 22 7,5 70,8 140,0 83323 65071 12 x 0,82 18 11,2 152,8 220,0
83292 65050 16 x 0,34 22 8,2 88,4 160,0 83324 65072 16 x 0,82 18 12,9 184,1 290,0
83293 65051 18 x 0,34 22 8,7 104,1 170,0 83325 65073 18 x 0,82 18 13,5 207,2 300,0
83294 65052 24 x 0,34 22 9,9 129,0 220,0 83326 65074 24 x 0,82 18 15,6 272,6 450,0
83295 65053 27 x 0,34 22 10,4 138,4 250,0 83327 65075 27 x 0,82 18 15,9 289,1 470,0
83296 65054 30 x 0,34 22 10,9 159,0 280,0 83328 65076 30 x 0,82 18 16,6 317,4 490,0
83302 65055 2 x 0,56 20 5,1 29,4 50,0 83334 65077 2 x 1,3 16 6,9 59,1 90,0
83303 65056 3 x 0,56 20 5,3 39,7 55,0 83335 65078 3 x 1,3 16 7,3 74,1 160,0
83304 65057 4 x 0,56 20 5,6 46,1 61,0 83336 65079 4 x 1,3 16 7,9 96,4 200,0
83305 65058 6 x 0,56 20 6,6 66,8 90,0 83337 65080 6 x 1,3 16 9,6 137,4 290,0
83306 65059 10 x 0,56 20 8,1 93,1 133,0 83338 65081 10 x 1,3 16 12,4 191,7 450,0
83307 65060 12 x 0,56 20 8,4 117,4 151,0 83339 65082 12 x 1,3 16 12,8 251,7 600,0
83308 65061 16 x 0,56 20 9,5 130,4 190,0 83340 65083 16 x 1,3 16 12,8 276,1 650,0
83309 65062 18 x 0,56 20 9,9 151,4 216,0 83341 65084 18 x 1,3 16 15,5 364,1 680,0
83310 65063 24 x 0,56 20 11,5 237,0 339,0 83342 65085 24 x 1,3 16 18,1 442,4 900,0
83311 65064 27 x 0,56 20 12,0 257,4 374,0 83343 65086 27 x 1,3 16 18,7 494,7 990,0
83312 65065 30 x 0,56 20 12,4 297,0 397,0 83344 65087 30 x 1,3 16 19,5 521,4 1050,0

Dimensions and specifications may be changed without prior notice. (RN02)

Suitable accessories can be found in Chapter X.


Cable tie

414
Cables according to international Approvals / Data Cables UL/CSA

Command Cable UL (LiYCY) Style 2516/600 V, 105C,


EMC-preferred type

Technical data Cable structure Properties


Special PVC command cable, approved to Tinned copper, fine wire conductors The materials used in manufacture are
UL-Style 2516 cores acc. UL-Style 10012 acc. to ASTM-B 174, class J-K cadmium-free and contain no silicone
Temperature range conductor make-up to and free from substances harmful to
flexing -10C to +105C 2,08 mm = 41x0,254 mm the wetting properties of lacquers
fixed installation -20C to +105C 3,20 mm = 65x0,254 mm Tests
Nominal voltage 600 V Core insulation of special PVC class 43 PVC flame retardant according to
Test voltage 2000 V acc. to UL-Std.1581 tabl.50.182 (105C) UL VW-1, CSA FT1
Breakdown voltage min. 4000 V Core identification to DIN 47100 or Conditionally resistant to
Minimum bending radius international colour code Oil
fixed 7,5x cable Cores stranded in layers with Solvents
flexing 15x cable optimal lay-length Acids
Coupling resistance Seperator-foil Lyes
max. 250 Ohm/km Drain wire
Tinned copper wire braiding, Note
approx. 85% coverage AWG sizes are approximate equivalent
Outer sheath of PVC class 43 acc. to values. The actual cross-section is in mm.
UL-Std.1581 tab.50.182 (105C) non-screened analogue types:
Sheath colour command cable UL (LiYY),
black (international colour code) confer page 404
grey (DIN 47100/preferred type from
stock)

Application
As a flexible interconnecting cable for electronics, control and command technology, as well as in measurement, signal, and pulse technology. Fast
and inexpensive contacting by cutting and clamping technology.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Part no. No.cores x AWG-No. Outer Cop. Weight Part no. Part no. No.cores x AWG-No. Outer Cop. Weight
N
Sheath Sheath cross-sec. app. weight app. Sheath Sheath cross-sec. app. weight app.
colour colour mm mm kg / km kg / km colour colour mm mm kg / km kg / km
grey black grey black
83350 65114 2 x 2,08 14 9,1 92,1 180,0 83362 65125 2 x 3,2 12 10,0 131,4 200,0
83351 65115 3 x 2,08 14 9,6 140,6 220,0 83363 65126 3 x 3,2 12 10,6 162,6 240,0
83352 65116 4 x 2,08 14 10,4 162,4 270,0 83364 65127 4 x 3,2 12 11,4 221,7 300,0
83353 65117 6 x 2,08 14 12,1 200,0 380,0 83365 65128 6 x 3,2 12 14,4 328,1 400,0
83354 65118 10 x 2,08 14 16,0 313,1 600,0 83366 65129 10 x 3,2 12 17,8 401,8 580,0
83355 65119 12 x 2,08 14 16,5 417,6 770,0 83367 65130 12 x 3,2 12 18,4 460,2 800,0
83356 65120 16 x 2,08 14 18,1 510,3 870,0 83368 65131 16 x 3,2 12 20,6 532,3 900,0
83357 65121 18 x 2,08 14 19,4 540,4 990,0 83369 65132 18 x 3,2 12 22,7 573,4 1000,0
83358 65122 24 x 2,08 14 23,4 0,0 1300,0 83370 65133 24 x 3,2 12 26,1 626,8 1300,0
83359 65123 27 x 2,08 14 23,9 604,2 1400,0
83360 65124 30 x 2,08 14 24,6 660,1 1610,0

Dimensions and specifications may be changed without prior notice. (RN02)

Suitable accessories can be found in Chapter X.


Cable tie

415
Cables according to international Approvals / Data Cables UL/CSA

TRAYCONTROL 300-C flexible, oil-resistant, screened,


EMC-preferred type, NFPA 79 Edition 2012

Technical data Cable structure Properties


Flexible screened PVC data and control Tinned copper conductor, fine wire The materials used in manufacture are
cable with AWG dimensions cadmium-free and contain no silicone
Temperature range Core insulation of special PVC and free from substances harmful to
-25C to +105C (AWG 22 - AWG 16 with transparent the wetting properties of lacquers
Nominal voltage 300 V nylon skin) Tests
Test voltage 2000 V Core identification to international self-extinguishing and flame retardant
Minimum bending radius colour code acc. to CSA FT4
flexing 6x cable Cores stranded in layers with optimal UL (AWG 22 - AWG 16):
Coupling resistance lay-length PLTC-ER, ITC-ER, Type CM, NFPA 79 2012,
max. 250 Ohm/km 1. Screen with special aluminium film OIL RES I & II, Class I Div. 2,
Radiation resistance 2.Tinned copper braided screen, NEC Art. 501, 725, 760 & 800, AWM 2517
up to 80x106 cJ/kg (up to 80 Mrad) approx. 85% UL (AWG 24 - AWG 28): CM, AWM
Separator 2464, rated OIL RES I & II,
Outer sheath of special PVC NEC Art. 725, 760 & 800, NFPA 79 2012
Sheath colour grey (RAL 7001) CSA: CSA CMG FT4, AWM I/II A/B FT4
with length marking in feet
Note
Advantages
Highly-flexible, easy to install
Oil-resistant to OIL RES I & II
Available on request
PUR or TPE outer sheath
Sheath colour to suit customer
requirement

Application
HELUKABEL TRAYCONTROL 300 is a screened, multi-core PVC data and control cable. Cross-sections with PLTC-ER and ITC-ER approval suitable
for open, unprotected installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as connecting
and joining cables and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates installation inside and
outside of machines and switch cabinets. The double-screening with aluminium foil (100% coverage) and copper braid (approx. 85% coverage)
guarantee superior EMC protection. Applications: tool machines, control panels, measuring devices, production automation, cable ducts, renewable
energies.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62710 0,093 2 x 28 4,5 6,0 16,0 62738 0,241 8 x 24 6,4 31,0 57,0
62711 0,093 3 x 28 4,7 7,0 22,0 62739 0,241 10 x 24 7,3 39,0 67,0
62712 0,093 4 x 28 5,0 9,0 27,0 62740 0,241 15 x 24 8,2 51,0 85,0
62713 0,093 6 x 28 5,5 12,0 34,0 62741 0,241 20 x 24 9,0 64,0 106,0
62714 0,093 8 x 28 5,8 15,0 37,0 62742 0,241 25 x 24 9,9 77,0 128,0
62715 0,093 10 x 28 6,4 18,0 43,0 62743 0,241 30 x 24 10,3 92,0 155,0
62716 0,093 15 x 28 7,0 24,0 52,0 62744 0,241 40 x 24 11,4 118,0 206,0
62717 0,093 20 x 28 7,6 30,0 67,0 62745 0,241 50 x 24 13,2 148,0 249,0
62718 0,093 25 x 28 8,6 37,0 79,0 62746 0,382 2 x 22 6,6 19,0 34,0
62719 0,093 30 x 28 8,9 43,0 88,0 62747 0,382 3 x 22 5,5 22,0 40,0
62720 0,093 40 x 28 9,7 54,0 112,0 62748 0,382 4 x 22 5,8 27,0 46,0
62721 0,093 50 x 28 11,4 67,0 131,0 62749 0,382 6 x 22 6,5 34,0 60,0
62722 0,154 2 x 26 4,7 9,0 24,0 62750 0,382 8 x 22 9,3 45,0 72,0
62723 0,154 3 x 26 4,9 10,0 27,0 62751 0,382 10 x 22 9,8 69,0 85,0
62724 0,154 4 x 26 5,1 12,0 31,0 62752 0,382 15 x 22 9,7 77,0 115,0
62725 0,154 6 x 26 5,8 16,0 39,0 62753 0,382 20 x 22 11,1 92,0 140,0
62726 0,154 8 x 26 6,1 19,0 43,0 62754 0,382 25 x 22 12,6 121,0 176,0
62727 0,154 10 x 26 6,8 24,0 51,0 62755 0,382 30 x 22 13,0 139,0 210,0
62728 0,154 15 x 26 7,5 31,0 66,0 62756 0,382 40 x 22 14,1 177,0 273,0
62729 0,154 20 x 26 8,3 40,0 79,0 62757 0,382 50 x 22 15,5 215,0 331,0
62730 0,154 25 x 26 9,2 49,0 92,0 62758 0,616 2 x 20 7,4 28,0 73,0
62731 0,154 30 x 26 9,5 57,0 110,0 62759 0,616 3 x 20 7,7 34,0 77,0
62732 0,154 40 x 26 10,4 72,0 136,0 62760 0,616 4 x 20 8,3 40,0 91,0
62733 0,154 50 x 26 12,1 88,0 165,0 62761 0,616 6 x 20 8,6 54,0 118,0
62734 0,241 2 x 24 4,9 15,0 30,0 62762 0,616 8 x 20 9,1 70,0 158,0
62735 0,241 3 x 24 5,1 16,0 33,0 62763 0,616 10 x 20 10,4 83,0 173,0
62736 0,241 4 x 24 5,3 19,0 37,0 62764 0,616 15 x 20 12,9 119,0 218,0
62737 0,241 6 x 24 6,1 27,0 48,0 62765 0,616 20 x 20 14,8 130,0 298,0

Continuation

416
Cables according to international Approvals / Data Cables UL/CSA

TRAYCONTROL 300-C flexible, oil-resistant, screened,


EMC-preferred type, NFPA 79 Edition 2012
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62766 0,616 25 x 20 16,0 186,0 401,0 62780 0,963 40 x 18 20,2 416,0 773,0
62767 0,616 30 x 20 16,5 224,0 477,0 62781 0,963 50 x 18 22,4 508,0 958,0
62768 0,616 40 x 20 18,7 288,0 623,0 62782 1,31 2 x 16 8,2 51,0 110,0
62769 0,616 50 x 20 20,7 337,0 752,0 62783 1,31 3 x 16 8,9 63,0 116,0
62770 0,963 2 x 18 7,8 37,0 80,0 62784 1,31 4 x 16 9,5 76,0 139,0
62771 0,963 3 x 18 8,1 49,0 86,0 62785 1,31 6 x 16 10,8 104,0 195,0
62772 0,963 4 x 18 8,8 58,0 101,0 62786 1,31 8 x 16 12,0 134,0 283,0
62773 0,963 6 x 18 10,0 82,0 130,0 62787 1,31 10 x 16 13,9 168,0 316,0
62774 0,963 8 x 18 10,6 100,0 168,0 62788 1,31 15 x 16 15,3 234,0 410,0
62775 0,963 10 x 18 12,8 124,0 226,0 62789 1,31 20 x 16 17,0 301,0 551,0
62776 0,963 15 x 18 14,3 180,0 295,0 62790 1,31 25 x 16 19,4 367,0 675,0
62777 0,963 20 x 18 15,5 234,0 386,0 62791 1,31 30 x 16 20,1 428,0 794,0
62778 0,963 25 x 18 17,7 277,0 462,0 62792 1,31 40 x 16 22,3 550,0 1033,0
62779 0,963 30 x 18 18,4 323,0 590,0 62793 1,31 50 x 16 25,1 669,0 1274,0

Dimensions and specifications may be changed without prior notice. (RN02)

Suitable accessories can be found in Chapter X.


Cable tie

417
Cables according to international Approvals / Data Cables UL/CSA

Command Cable UL (LiYCY-TP) Style 2464/300 V, 80C,


EMC-preferred type

Technical data Cable structure Properties


Special PVC command cable, approved to Tinned copper, fine wire conductors acc. to The materials used in manufacture are
UL-Style 2464, ASTM-B 174-95 class J-M cadmium-free and contain no silicone
cores acc. to UL-Style 1061/1729 Conductor make-up to and free from substances harmful to
Temperature range 0,14 mm = 7x0,162 mm the wetting properties of lacquers
flexing -10C to +80C 0,23 mm = 7x0,202 mm Tests
fixed installation -20C to +80C 0,34 mm = 7x0,254 mm PVC flame retardant acc. to
Nominal voltage 300 V 0,56 mm = 7x0,32 mm UL VW-1, CSA FT1
Test voltage 1500 V Core insulation of special PVC Conditionally resistant to
Breakdown voltage min. 3000 V class 43 respectively semirigid acc. to Oil
Insulation resistance UL-Std.1581 tab.50.182 and 50183 Solvents
min. 100 MOhm x km Core identification (pair) to DIN 47100 Acids
Minimum bending radius with colour repetition from pair no. 23 and Lyes
fixed 7,5x cable above or international colour code
flexing 15x cable Cores stranded in pairs to optimal Note
Coupling resistance lay-length AWG sizes are approximate equivalent
max. 250 Ohm/km Pairs stranded with optimal values. The actual cross-section is in mm.
lay-length in layers non-screened analogue type:
Seperator-foil command cable UL (LiYY-TP),
Drain wire confer page 407
Tinned copper wire braiding,
approx. 85% coverage
Outer sheath of special PVC
class 43 acc. to UL-Std.1581 tab.50.182
Sheath colour
black (international colour code)
grey (DIN 47100 - preferred type from
stock)

Application
Flexiblescreenedpaircableconnection,as control,signaland measuring cablesin tool machinery,conveyor belts and,inplant construction,air conditioning,in
foundries and steel mills.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x AWG-No. Outer Cop. Weight Part no. No.pairs x AWG-No. Outer Cop. Weight
Sheath Sheath cross-sec. app. mm weight app. Sheath Sheath cross-sec. app. mm weight app.
colour colour mm kg / km kg / km colour colour mm kg / km kg / km
grey black grey black
83774 65314 1 x 2 x 0,14 26 4,0 15,7 32,0 83792 65332 1 x 2 x 0,23 24 4,2 16,4 46,0
83775 65315 2 x 2 x 0,14 26 5,6 19,5 39,0 83793 65333 2 x 2 x 0,23 24 5,9 27,4 53,0
83776 65316 3 x 2 x 0,14 26 5,8 23,7 47,0 83794 65334 3 x 2 x 0,23 24 6,2 31,7 65,0
83777 65317 4 x 2 x 0,14 26 6,3 26,9 55,0 83795 65335 4 x 2 x 0,23 24 6,7 37,4 79,0
83778 65318 5 x 2 x 0,14 26 6,7 31,2 68,0 83796 65336 5 x 2 x 0,23 24 7,2 54,7 98,0
83779 65319 6 x 2 x 0,14 26 7,3 49,7 86,0 83797 65337 6 x 2 x 0,23 24 7,7 65,6 114,0
83780 65320 7 x 2 x 0,14 26 7,3 52,0 92,0 83798 65338 7 x 2 x 0,23 24 7,7 60,2 121,0
83781 65321 8 x 2 x 0,14 26 7,8 53,9 97,0 83799 65339 8 x 2 x 0,23 24 8,4 74,1 129,0
83782 65322 10 x 2 x 0,14 26 9,1 59,6 111,0 83800 65340 10 x 2 x 0,23 24 9,9 109,3 152,0
83783 65323 12 x 2 x 0,14 26 9,8 67,1 141,0 83801 65341 12 x 2 x 0,23 24 10,2 115,8 189,0
83784 65324 14 x 2 x 0,14 26 10,5 75,2 150,0 83802 65342 14 x 2 x 0,23 24 10,9 120,7 213,0
83785 65325 15 x 2 x 0,14 26 11,1 77,3 154,0 83803 65343 15 x 2 x 0,23 24 11,4 132,4 225,0
83786 65326 16 x 2 x 0,14 26 11,1 80,4 155,0 83804 65344 16 x 2 x 0,23 24 11,4 141,6 227,0
83787 65327 18 x 2 x 0,14 26 11,8 84,2 170,0 83805 65345 18 x 2 x 0,23 24 12,2 146,6 238,0
83788 65328 20 x 2 x 0,14 26 12,4 98,2 183,0 83806 65346 20 x 2 x 0,23 24 12,7 160,6 270,0
83789 65329 22 x 2 x 0,14 26 13,1 104,1 207,0 83807 65347 22 x 2 x 0,23 24 13,5 170,8 300,0
83790 65330 24 x 2 x 0,14 26 13,6 112,0 228,0 83808 65348 24 x 2 x 0,23 24 14,5 229,7 321,0
83791 65331 25 x 2 x 0,14 26 15,1 114,4 239,0 83809 65349 25 x 2 x 0,23 24 14,8 231,4 340,0

Continuation

418
Cables according to international Approvals / Data Cables UL/CSA

Command Cable UL (LiYCY-TP) Style 2464/300 V, 80C,


EMC-preferred type
Part no. No.pairs x AWG-No. Outer Cop. Weight Part no. No.pairs x AWG-No. Outer Cop. Weight
Sheath Sheath cross-sec. app. mm weight app. Sheath Sheath cross-sec. app. mm weight app.
colour colour mm kg / km kg / km colour colour mm kg / km kg / km
grey black grey black
83810 65350 1 x 2 x 0,34 22 4,6 17,0 58,0 83828 65368 1 x 2 x 0,56 20 5,0 26,0 70,0
83811 65351 2 x 2 x 0,34 22 6,4 36,7 65,0 83829 65369 2 x 2 x 0,56 20 7,0 56,1 89,0
83812 65352 3 x 2 x 0,34 22 6,9 44,6 78,0 83830 65370 3 x 2 x 0,56 20 7,6 71,7 102,0
83813 65353 4 x 2 x 0,34 22 7,5 54,1 88,0 83831 65371 4 x 2 x 0,56 20 8,3 92,4 119,0
83814 65354 5 x 2 x 0,34 22 8,1 63,4 110,0 83832 65372 5 x 2 x 0,56 20 9,1 107,4 140,0
83815 65355 6 x 2 x 0,34 22 8,8 73,4 126,0 83833 65373 6 x 2 x 0,56 20 10,1 122,4 162,0
83816 65356 7 x 2 x 0,34 22 8,8 79,4 140,0 83834 65374 7 x 2 x 0,56 20 10,1 131,7 198,0
83817 65357 8 x 2 x 0,34 22 9,7 88,4 148,0 83835 65375 8 x 2 x 0,56 20 12,7 144,3 272,0
83818 65358 10 x 2 x 0,34 22 11,5 107,0 184,0 83836 65376 10 x 2 x 0,56 20 13,2 179,6 307,0
83819 65359 12 x 2 x 0,34 22 12,0 122,4 210,0 83837 65377 12 x 2 x 0,56 20 13,6 201,7 318,0
83820 65360 14 x 2 x 0,34 22 12,6 138,2 241,0 83838 65378 14 x 2 x 0,56 20 14,4 221,4 342,0
83821 65361 15 x 2 x 0,34 22 13,4 154,3 245,0 83839 65379 15 x 2 x 0,56 20 15,5 231,6 381,0
83822 65362 16 x 2 x 0,34 22 13,4 161,4 251,0 83840 65380 16 x 2 x 0,56 20 15,5 257,1 417,0
83823 65363 18 x 2 x 0,34 22 14,4 197,9 275,0 83841 65381 18 x 2 x 0,56 20 16,3 282,4 494,0
83824 65364 20 x 2 x 0,34 22 15,0 211,4 300,0 83842 65382 20 x 2 x 0,56 20 17,1 306,7 570,0
83825 65365 22 x 2 x 0,34 22 15,9 217,6 320,0 83843 65383 22 x 2 x 0,56 20 18,0 321,8 643,0
83826 65366 24 x 2 x 0,34 22 17,0 230,4 371,0 83844 65384 24 x 2 x 0,56 20 19,4 342,4 724,0
83827 65367 25 x 2 x 0,34 22 17,3 138,5 402,0 83845 65385 25 x 2 x 0,56 20 19,8 361,2 740,0

Dimensions and specifications may be changed without prior notice. (RN02)

Suitable accessories can be found in Chapter X.


Cable tie

419
Cables according to international Approvals / Data Cables UL/CSA

TRAYCONTROL 300-C TP twisted pair, flexible, screened,


oil-resistant, EMC-preferred type, NFPA 79 Edition 2012

Technical data Cable structure Properties


Flexible screened PVC data and control Tinned copper conductor, fine wire Self-extinguishing and flame retardant in
cable stranded, with AWG measures acc. to CSA FT4
Temperature range Core insulation of special PVC The materials used in manufacture are
-25C to +105C (AWG 22 - AWG 18 with transparent nylon cadmium-free and contain no silicone
Nominal voltage 300 V skin) and free from substances harmful to
Test voltage 2000 V Core identification (pair) acc. to the wetting properties of lacquers
Minimum bending radius international colour code Tests
flexing 6x cable Cores stranded in pairs with optimal UL (AWG 22 - AWG 18):
Coupling resistance lay-length PLTC-ER, ITC-ER, CM, NFPA 79 2012,
max. 250 Ohm/km Pairs stranded in layers with optimal OIL RES I & II, Class I Div. 2, NEC Art.
Radiation resistance lay-length 501, 725, 760 & 800, AWM 2517
up to 80x106 cJ/kg (up to 80 Mrad) 1. Screening with special aluminium foil UL (AWG 24 - AWG 26):
2. Tinned copper braided screen, CM, AWM 2517, rated OIL RES I & II,
approx. 85% coverage NEC Art. 725, 760 & 800, NFPA 79 2012
Separator CSA:
Outer sheath of special PVC CSA CMG FT4, AWM I/II A/B FT4
Sheath colour grey (RAL 7001)
with length marking in feet Note
Advantages
Highly-flexible, easy to install
Oil-resistant to OIL RES I & II
Available on request
PUR or TPE outer sheath
Sheath colour to suit customer
requirement

Application
HELUKABEL TRAYCONTROL 300 is a screened, twisted pair data and control cable. Cross-sections with PLTC-ER and ITC-ER approval suitable for
open, unprotected installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as connecting
and joining cables and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates installation inside and
outside of machines and switch cabinets. The double-screening with aluminium foil (100% coverage) and copper braid (approx. 85% coverage)
guarantee superior EMC protection. Applications: tool machines, control panels, measuring devices, production automation, cable ducts, renewable
energies.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cross- No.pairs x Outer Cop. Weight Part no. Cross- No.pairs x Outer Cop. Weight
section mm No.cores app. mm weight app. section mm No.cores app. mm weight app.
x kg / km kg / km x kg / km kg / km
AWG-no. AWG-no.
61999 0,154 1 x 2 x 26 4,7 16,0 32,0 59785 0,241 10 x 2 x 24 10,5 109,0 152,0
59760 0,154 2 x 2 x 26 5,7 20,0 39,0 59786 0,241 12 x 2 x 24 10,8 116,0 189,0
59761 0,154 3 x 2 x 26 5,9 24,0 47,0 59787 0,241 14 x 2 x 24 12,6 121,0 213,0
59762 0,154 4 x 2 x 26 6,4 27,0 55,0 59788 0,241 15 x 2 x 24 12,4 132,0 225,0
59763 0,154 5 x 2 x 26 6,8 31,0 68,0 59789 0,241 16 x 2 x 24 12,9 142,0 227,0
59764 0,154 6 x 2 x 26 7,4 50,0 86,0 59790 0,241 18 x 2 x 24 13,8 147,0 238,0
59765 0,154 7 x 2 x 26 7,5 52,0 92,0 59791 0,241 20 x 2 x 24 14,4 161,0 270,0
59766 0,154 8 x 2 x 26 7,9 54,0 97,0 59792 0,241 22 x 2 x 24 15,3 171,0 300,0
59767 0,154 10 x 2 x 26 9,2 60,0 111,0 59793 0,241 24 x 2 x 24 16,4 230,0 321,0
59768 0,154 12 x 2 x 26 9,8 67,0 141,0 59794 0,241 25 x 2 x 24 16,7 231,0 340,0
59769 0,154 14 x 2 x 26 10,4 75,0 150,0 59795 0,382 1 x 2 x 22 6,9 17,0 58,0
59770 0,154 15 x 2 x 26 10,8 77,0 154,0 59796 0,382 2 x 2 x 22 9,3 37,0 65,0
59771 0,154 16 x 2 x 26 11,2 80,0 155,0 59797 0,382 3 x 2 x 22 9,7 45,0 79,0
59772 0,154 18 x 2 x 26 11,8 84,0 170,0 59798 0,382 4 x 2 x 22 10,5 54,0 88,0
59773 0,154 20 x 2 x 26 12,4 98,0 183,0 59799 0,382 5 x 2 x 22 11,4 63,0 110,0
59774 0,154 22 x 2 x 26 13,1 104,0 207,0 59800 0,382 6 x 2 x 22 12,1 73,0 126,0
59775 0,154 24 x 2 x 26 13,6 112,0 228,0 59801 0,382 7 x 2 x 22 12,3 79,0 140,0
59776 0,154 25 x 2 x 26 15,1 114,0 239,0 59802 0,382 8 x 2 x 22 13,2 88,0 148,0
59777 0,241 1 x 2 x 24 4,9 16,0 46,0 59803 0,382 10 x 2 x 22 15,7 107,0 184,0
59778 0,241 2 x 2 x 24 6,6 27,0 53,0 59804 0,382 12 x 2 x 22 16,0 122,0 210,0
59779 0,241 3 x 2 x 24 6,9 32,0 65,0 59805 0,382 14 x 2 x 22 16,3 138,0 241,0
59780 0,241 4 x 2 x 26 7,8 37,0 79,0 59806 0,382 15 x 2 x 22 16,6 154,0 245,0
59781 0,241 5 x 2 x 24 8,0 55,0 98,0 59807 0,382 16 x 2 x 22 16,8 161,0 251,0
59782 0,241 6 x 2 x 24 8,4 66,0 114,0 59808 0,382 18 x 2 x 22 17,8 198,0 275,0
59783 0,241 7 x 2 x 24 8,8 60,0 121,0 59809 0,382 20 x 2 x 22 18,4 211,0 300,0
59784 0,241 8 x 2 x 24 9,5 74,0 129,0 59810 0,382 22 x 2 x 22 19,3 218,0 320,0

Continuation

420
Cables according to international Approvals / Data Cables UL/CSA

TRAYCONTROL 300-C TP twisted pair, flexible, screened,


oil-resistant, EMC-preferred type, NFPA 79 Edition 2012
Part no. Cross- No.pairs x Outer Cop. Weight Part no. Cross- No.pairs x Outer Cop. Weight
section mm No.cores app. mm weight app. section mm No.cores app. mm weight app.
x kg / km kg / km x kg / km kg / km
AWG-no. AWG-no.
59811 0,382 24 x 2 x 22 20,5 230,0 371,0 59824 0,616 15 x 2 x 20 19,5 232,0 381,0
59812 0,382 25 x 2 x 22 20,8 239,0 402,0 59825 0,616 16 x 2 x 20 19,6 257,0 417,0
59813 0,616 1 x 2 x 20 7,4 26,0 70,0 59826 0,616 18 x 2 x 20 20,6 282,0 494,0
59814 0,616 2 x 2 x 20 10,0 56,0 89,0 59827 0,616 20 x 2 x 20 21,6 307,0 570,0
59815 0,616 3 x 2 x 20 10,8 72,0 102,0 59828 0,616 22 x 2 x 20 22,7 322,0 643,0
59816 0,616 4 x 2 x 20 11,5 92,0 119,0 59829 0,616 24 x 2 x 20 24,5 342,0 724,0
59817 0,616 5 x 2 x 20 12,6 107,0 140,0 59830 0,616 25 x 2 x 20 24,9 361,0 740,0
59818 0,616 6 x 2 x 20 13,4 122,0 162,0 59831 0,963 1 x 2 x 18 7,8 28,0 104,0
59819 0,616 7 x 2 x 20 13,5 132,0 198,0 59832 0,963 2 x 2 x 18 10,3 57,0 121,0
59820 0,616 8 x 2 x 20 16,9 144,0 272,0 59833 0,963 3 x 2 x 18 11,6 75,0 150,0
59821 0,616 10 x 2 x 20 17,6 180,0 307,0 59834 0,963 6 x 2 x 18 14,7 139,0 328,0
59822 0,616 12 x 2 x 20 18,1 202,0 318,0 59835 0,963 9 x 2 x 18 17,3 212,0 490,0
59823 0,616 14 x 2 x 20 19,2 221,0 342,0 59836 0,963 15 x 2 x 18 21,4 358,0 811,0

Dimensions and specifications may be changed without prior notice. (RN02)

Suitable accessories can be found in Chapter X.


Cable tie

421
UL/CSA DRAG CHAIN CABLES

422
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA

JZ-602 RC cable for drag chains, 90C, 600 V, two approval control
cable, meter marking

Technical data Cable structure Properties


Control cable of special-PVC to Bare copper, extra fine wire conductors, to The materials used in manufacture are
UL AWM Style 10012 (core insulation) DIN VDE 0295 cl.6 col. 4, BS 6360 cl.6 and cadmium-free and contain no silicone
Style 2587 and CSA IEC 60228 cl.6 and free from substances harmful to
Temperature range Core insulation special PVC the wetting properties of lacquers
flexing -5C to +90C compound type YI8 to Tests
fixed installation -40C to +90C DIN VDE 0207 part 4 and class 43 PVC self-extinguishing and flame retardant
Nominal voltage acc. to UL-Std.1581 acc. to DIN VDE 0482-332-1-2,
UL/CSA 600 V Core identification to DIN VDE 0293 DIN EN 60332-1-2/IEC 60332-1 (equivalent
Test voltage 4000 V red cores with continuous white DIN VDE 0472 part 804 test method B),
Breakdown voltage min. 8000 V numbering UL VW-1, CSA FT1
Insulation resistance GN-YE conductor in the outer layer UV-resistant
min 20 MOhm x km Cores stranded in layers with
Minimum bending radius optimal lay-length Note
flexing 7,5x cable Wrapping with fleece over each layer G = with green-yellow conductor
fixed installation 4x cable Outer sheath of special PVC AWG sizes are approximate equivalent
Radiation resistance compound type YM5 to values. The actual cross-section is in mm.
up to 80x106 cJ/kg (up to 80 Mrad) DIN VDE 0207 part 5, UL-Style 2587 and screened analogue type:
CSA C22.2 No 210 JZ-602 RC -CY, confer page 427
Sheath colour black (RAL 9005)
with meter marking

Application
For use in dry, damp and wet rooms with free movement without tensile stress or forced movements as highly flexible PVC control cable suitable for
frequent lifting and bending stress in the machinery and tooling, robot technology and permanently moving machine parts. Convincingly proved in
the standard use of drag chains. Interesting for the export-oriented machinery plant. For applications that go beyond standard solutions (e. g.
composting facilities or high shelf conveyors with extremely high speed, etc.) we recommend you to our specially developed inquiry sheet for energy
guiding systems, further technical details see selection table: Conductors for cable drag chains in the opening credits. For use in cable drag chains
please note installation instruction.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC. N
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
89900 3 G 0,5 20 6,0 14,0 58,0 89926 25 G 1,5 16 19,8 360,0 625,0
89901 4 G 0,5 20 6,5 19,0 69,0 89927 34 G 1,5 16 22,4 490,0 840,0
89902 5 G 0,5 20 7,1 24,0 84,0 89932 3 G 2,5 14 8,9 72,0 150,0
89903 7 G 0,5 20 8,2 34,0 123,0 89928 4 G 2,5 14 10,1 96,0 185,0
89904 9 G 0,5 20 10,0 43,2 177,0 89933 5 G 2,5 14 11,3 120,0 242,0
89905 12 G 0,5 20 10,5 58,2 192,0 89929 7 G 2,5 14 13,6 168,0 293,0
89906 18 G 0,5 20 12,5 86,0 256,0 89934 12 G 2,5 14 16,8 288,0 498,0
89907 25 G 0,5 20 15,2 120,0 358,0 89935 3G4 12 10,9 115,0 231,0
89908 34 G 0,5 20 17,1 163,0 487,0 89930 4G4 12 12,4 154,0 298,0
89909 3G1 18 6,6 23,8 88,0 89936 5G4 12 13,8 192,0 370,0
89910 4G1 18 7,1 31,7 101,0 89931 7G4 12 16,6 269,0 460,0
89911 5G1 18 7,8 39,6 126,0 89937 4G6 10 14,6 231,0 430,0
89912 7G1 18 9,2 55,4 145,0 89938 4 G 10 8 18,2 384,0 720,0
89913 9G1 18 11,0 71,2 168,0 89939 4 G 16 6 22,6 615,0 1060,0
89914 12 G 1 18 11,5 95,0 260,0 89940 4 G 25 4 26,5 960,0 1590,0
89915 15 G 1 18 13,2 119,0 300,0 89941 4 G 35 2 30,8 1344,0 2105,0
89916 18 G 1 18 14,0 142,4 360,0
89917 25 G 1 18 17,2 197,8 640,0
89918 34 G 1 18 19,1 269,0 730,0
89919 3 G 1,5 16 7,4 44,0 94,0
89920 4 G 1,5 16 8,0 58,0 117,0
89921 5 G 1,5 16 8,8 72,0 140,0
89922 7 G 1,5 16 10,8 101,0 186,0
89923 9 G 1,5 16 12,8 129,7 244,0
89924 12 G 1,5 16 13,5 173,0 319,0
89925 18 G 1,5 16 16,0 260,0 451,0

Dimensions and specifications may be changed without prior notice. (RN05)

423
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA

MULTIFLEX 600 highly flexible, oil-resistant, open installation


TC-ER, PLTC-ER, NFPA 79 Edition 2012

Technical data Cable structure Properties


Highly-flexible PVC control cable according Bare copper conductor, extra-fine wire Self-extinguishing and flame retardant in
to UL-Std.1277 stranded, with AWG measures acc. to CSA FT4
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -5C to +90C with transparent nylon skin cadmium-free and contain no silicone
fixed installation -40C to +90C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage black cores with continuous white the wetting properties of lacquers
TC 600 V numbering UV-resistant
TC Wind Turbine (WTTC) 1000 V GN-YE conductor, 3 cores Tests
Test voltage 3000 V and abovein the outer layer UL:
Minimum bending radius Cores stranded in layers with TC-ER, PLTC-ER (AWG 18 - AWG 12),
flexing 7,5x cable optimal lay-lengths ITC-ER (AWG 18 - AWG 12), MTW,
Insulation resistance Separator NFPA 79 2012, WTTC 1000 V, DP-1,
min. 20 MOhm x km Outer sheath of special PVC OIL RES I&II, 90C dry / 75C wet,
Radiation resistance Sheath colour black (RAL 9005) Class 1 Div. 2 per NEC Art 336, 392, 501,
up to 80x106 cJ/kg (up to 80 Mrad) with length marking in feet crush impact test in accordance
with UL 1277
CSA:
c(UL) CIC-TC FT4, CSA AWM I/II A/B FT4

Note
Advantages
Highly-flexible, simple installation
Available on request
with blue cores (DC)
with red cores (AC)
Grey or TPE outer sheath

Application
HELUKABEL MULTIFLEX 600 is a highly-flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this cable
to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 edition 2012. Approved for open, unprotected
installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life; for industrial applications in dry,
damp and wet environments. Recommended applications: production lines, bottling plants, machine construction, switch cabinets, conveyor systems,
packaging machines, automotive industry. Please observe applicable installation regulations for use in energy supply chains.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
62502 2 x 0,5 20 6,9 10,0 53,0 62529 25 G 1,5 16 20,8 360,0 665,0
62503 3 G 0,5 20 7,3 14,0 61,0 62530 34 G 1,5 16 23,0 490,0 1084,0
62504 4 G 0,5 20 8,0 19,0 72,0 62531 41 G 1,5 16 25,1 590,0 1260,0
62505 5 G 0,5 20 8,6 24,0 85,0 62532 50 G 1,5 16 27,7 720,0 1521,0
62506 7 G 0,5 20 9,9 34,0 110,0 62533 60 G 1,5 16 29,5 864,0 1885,0
62507 12 G 0,5 20 11,4 58,0 158,0 62534 3 G 2,5 14 9,8 72,0 160,0
62508 18 G 0,5 20 14,2 86,0 241,0 63136 4 G 2,5 14 10,6 96,0 173,0
62509 25 G 0,5 20 17,0 120,0 316,0 62535 5 G 2,5 14 11,9 120,0 268,0
62510 34 G 0,5 20 18,9 163,0 439,0 62536 7 G 2,5 14 13,6 168,0 307,0
62511 3 G 0,75 18 7,8 22,0 75,0 62537 9 G 2,5 14 16,1 216,0 437,0
62512 4 G 0,75 18 8,6 29,0 91,0 62538 12 G 2,5 14 16,9 288,0 572,0
62513 5 G 0,75 18 9,3 36,0 103,0 62539 18 G 2,5 14 20,1 432,0 800,0
62514 7 G 0,75 18 10,8 50,0 136,0 62540 25 G 2,5 14 25,1 600,0 1100,0
62515 12 G 0,75 18 12,4 86,0 228,0 62541 3G4 12 11,3 115,0 221,0
62516 15 G 0,75 18 13,8 108,0 273,0 62542 4G4 12 12,4 154,0 247,0
62517 18 G 0,75 18 15,4 130,0 311,0 62543 5G4 12 13,8 192,0 318,0
62518 25 G 0,75 18 18,5 180,0 498,0 62544 7G4 12 16,9 269,0 438,0
62519 34 G 0,75 18 20,5 245,0 550,0 62545 4G6 10 15,3 230,0 383,0
62520 36 G 0,75 18 20,6 259,0 570,0 62546 5G6 10 16,6 288,0 481,0
62521 42 G 0,75 18 22,3 302,0 600,0 62547 7G6 10 18,2 403,0 800,0
62522 3 G 1,5 16 8,6 43,0 100,0 62548 4 G 10 8 19,7 384,0 671,0
62523 4 G 1,5 16 9,5 58,0 122,0 62549 5 G 10 8 22,0 480,0 990,0
62524 5 G 1,5 16 10,3 72,0 148,0 62550 4 G 16 6 23,7 614,0 951,0
62525 7 G 1,5 16 12,0 101,0 197,0 62551 5 G 16 6 26,1 768,0 1500,0
62526 9 G 1,5 16 14,2 130,0 244,0 62552 4 G 25 4 34,0 960,0 1700,0
62527 12 G 1,5 16 14,7 173,0 328,0 62554 4 G 35 2 37,0 1344,0 2300,0
62528 18 G 1,5 16 17,2 259,0 459,0

Dimensions and specifications may be changed without prior notice. (RN01)

424
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA

MULTISPEED 500-PVC UL/CSA high flexible, safety


against high bending in drag chain systems, oil-resistant, low torsion, meter marking

Technical data Cable structure Properties


Special drag chain cables for high Bare copper, fine wire conductors, The materials used in manufacture are
mechanical stress in adapted to Unilay with short pitch length cadmium-free and contain no silicone
DIN VDE 0285-525-2-51/ Core insulation of special PP and free from substances harmful to
DIN EN 50525-2-51 Core identification to DIN VDE 0293 the wetting properties of lacquers0
to UL-Std.758 AWM Style 21179 black cores with continuous white Tests
Temperature range numbering PVC outer sheath self-extinguishing and
flexing -5C to +80C GN-YE conductor, 3 cores and above flame retardant acc. to DIN VDE
fixed installation -30C to +80C Stranding: 0482-332-1-2,
Nominal voltage <7 cores: cores stranded in a layer with DIN EN 60332-1-2, IEC 60332-1 (equivalent
VDE U0/U 300/500 V optimal lay-length around a filler as per DIN VDE 0472 part 804
UL 600 V construction test method B), UL VW-1, CSA FT1
Test voltage 3000 V 7 cores: cores stranded with optimal Low-adhesion
Insulation resistance lay-length to bunch-construction with low Ozon and UV resistant
min. 100 MOhm x km torsion strength, optimal selected short High property of alternating bending
Minimum bending radius lay-length around a filler strength
flexing 7,5x cable Outer sheath special PVC, especially longer service life due to low
fixed installation 4x cable resistant against fatigue strength, extruded frictional resistance
Radiation resistance as filler with pressure Better chemical resistance
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour black (RAL 9005) Oil resistance to DIN VDE 0473-811-404/
with meter marking DIN EN 60811-404
Reduced , therefore low moving
masses

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED 500-C-PVC UL/CSA,
N
confer page 429

Application
UL/CSA approved HELUKABEL MULTISPEED 500-PVC are installed there, where extreme requirements for the cables are necessary. Designed for
the export-orientated machinery manufacturer, specifically for USA and Canada. Matched materials and stranding technique permit continuous use
as a highly flexible cable for drag chains with long travel and high or slow speeds. For use in dry, damp rooms, and outdoors, with free movement
without tensile stress or forced movements as a highly flexible PVC control cable suitable for frequent lifting and bending stress in engineering and
tool manufacturing.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24295 2 x 0,5 20 4,8 9,6 40,0 24315 12 G 1 18 12,3 115,0 227,0
24296 3 G 0,5 20 5,1 14,4 45,0 24316 18 G 1 18 15,1 173,0 351,0
24297 4 G 0,5 20 5,5 19,0 57,0 24317 25 G 1 18 17,6 240,0 489,0
24298 5 G 0,5 20 6,0 24,0 66,0 24318 3 G 1,5 16 6,7 43,0 88,0
24299 7 G 0,5 20 9,1 33,6 81,0 24319 4 G 1,5 16 7,3 58,0 110,0
24300 12 G 0,5 20 10,0 58,0 133,0 24320 5 G 1,5 16 8,0 72,0 130,0
24301 18 G 0,5 20 12,2 86,0 194,0 24321 7 G 1,5 16 13,2 101,0 182,0
24302 25 G 0,5 20 14,3 120,0 274,0 24322 12 G 1,5 16 14,4 173,0 319,0
24303 4 G 0,75 19 6,1 29,0 63,0 24323 18 G 1,5 16 17,7 259,0 420,0
24304 5 G 0,75 19 6,6 36,0 79,0 24324 25 G 1,5 16 20,5 360,0 604,0
24305 7 G 0,75 19 10,5 50,0 107,0 24325 4 G 2,5 14 8,9 96,0 172,0
24306 12 G 0,75 19 11,4 86,0 169,0 24326 5 G 2,5 14 9,9 120,0 219,0
24307 18 G 0,75 19 14,2 130,0 247,0 24327 7 G 2,5 14 16,1 168,0 303,0
24308 25 G 0,75 19 16,3 180,0 366,0 24328 12 G 2,5 14 17,8 288,0 504,0
24309 36 G 0,75 19 20,1 259,0 540,0 24329 18 G 2,5 14 21,8 432,0 754,0
24310 42 G 0,75 19 22,2 302,0 630,0 24330 25 G 2,5 14 24,4 600,0 940,0
24311 3G1 18 5,9 29,0 69,0
24312 4G1 18 6,4 38,4 86,0
24313 5G1 18 7,0 48,0 101,0
24314 7G1 18 11,2 67,0 140,0

Dimensions and specifications may be changed without prior notice. (RN05)

425
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA

JZ-HF-FCY high flexible, cable for drag chains, oil resistant, EMC-preferred
type, meter marking

Technical data Cable structure Properties


Special PVC drag chain cable, extreme Bare copper, fine wire conductors, to The materials used in manufacture are
flexibility acc. to UL/CSA AWM I/II A/B DIN VDE 0295 cl.5, BS 6360 cl.5 cadmium-free and contain no silicone
Style 2570 and IEC 60228 cl.5 and free from substances harmful to
Temperature range Core insulation of special PVC the wetting properties of lacquers
flexing -5C to +80C acc. to UL-Std.1581 Tests
fixed installation -40C to +80C Core identification to DIN VDE 0293 PVC self-extinguishing and flame retardant
Nominal voltage black cores with continuous white acc. to DIN VDE 0482-332-1-2,
VDE U0/U 300/500 V numbering DIN EN 60332-1-2 / IEC 60332-1
UL/CSA 1000 V GN-YE conductor, 3 cores and above (equivalent DIN VDE 0472 part 804
Test voltage 4000 V in the outer layer test method B), UL VW-1, CSA FT1
Breakdown voltage min. 8000 V Cores stranded in layers with optimal low adhesion
Insulation resistance selected lay-length oil resistant to DIN VDE 0473-811-404 /
min. 20 MOhm x km Separating foil over each layer DIN EN 60811-404
Minimum bending radius construction with Cu-screening, tinned,
flexing 10x cable approx. 85% Note
fixed installation 5x cable Minimum coverage 85% G = with green-yellow conductor
Coupling resistance Outer sheath of special PVC x = without green-yellow conductor (OZ)
max. 250 Ohm/km compound type TM5 to AWG sizes are approximate equivalent
Radiation resistance DIN VDE 0207-363-4-1/DIN EN 50363-4-1 values. The actual cross-section is in mm.
up to 80x106 cJ/kg (up to 80 Mrad) acc. to UL-Std.1581 unscreened analogue type:
Sheath colour grey (RAL 7001) JZ-602 RC, confer page 423
with meter marking MULTISPEED 500-PVC UL/CSA,
confer page 425

Application
UL/CSA approved, highly flexible, screened PVC drag-chain cable for laying in dry, damp and wet rooms, with free movement and without tensile
load or forced movements, suitable for frequent lifting and bending stresses in the sector of machine manufacture and tool making. Thanks to the
high level of shielding density, a fault-free transmission of signals or impulses is ensured. The ideal control line, offering protection against interference,
for the above applications. Of interest for those machinery manufacturers, who are export orientated. For applications which go beyond standard
solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially
developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection
table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12908 2 x 0,5 20 6,0 35,0 46,0 12926 4G1 18 7,8 71,0 114,0
12909 3 G 0,5 20 6,3 42,0 56,0 12927 5G1 18 8,4 88,0 136,0
12910 4 G 0,5 20 6,8 47,0 64,0 12928 7G1 18 9,8 111,0 169,0
12911 5 G 0,5 20 7,4 56,0 77,0 12929 12 G 1 18 12,0 184,0 270,0
12912 7 G 0,5 20 8,5 69,0 104,0 12930 18 G 1 18 14,2 260,0 385,0
12913 12 G 0,5 20 10,1 108,0 158,0 12931 25 G 1 18 16,8 349,0 530,0
12914 18 G 0,5 20 11,7 145,0 229,0 12932 2 x 1,5 16 7,3 63,0 88,0
12915 25 G 0,5 20 14,0 240,0 320,0 12933 3 G 1,5 16 7,7 80,0 104,0
12916 2 x 0,75 19 6,4 40,0 59,0 12934 4 G 1,5 16 8,4 97,0 136,0
12917 3 G 0,75 19 6,8 52,0 68,0 12935 5 G 1,5 16 9,1 119,0 170,0
12918 4 G 0,75 19 7,3 60,0 82,0 12936 7 G 1,5 16 10,7 147,0 221,0
12919 5 G 0,75 19 7,9 71,0 101,0 12937 12 G 1,5 16 13,0 267,0 348,0
12920 7 G 0,75 19 9,2 91,0 150,0 12938 18 G 1,5 16 15,5 374,0 489,0
12921 12 G 0,75 19 11,0 142,0 212,0 12939 25 G 1,5 16 18,7 526,0 710,0
12922 18 G 0,75 19 13,0 212,0 305,0 12940 3 G 2,5 14 9,1 144,0 177,0
12923 25 G 0,75 19 15,8 281,0 430,0 12941 4 G 2,5 14 9,9 148,0 204,0
12924 2x1 18 6,8 50,0 71,0 12942 7 G 2,5 14 13,0 255,0 340,0
12925 3G1 18 7,2 60,0 90,0 12943 4G4 12 11,2 230,0 310,0

Dimensions and specifications may be changed without prior notice. (RN05)

426
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA

JZ-602 RC-CY special cable for drag chains, 90C, 600 V, two
approval control cable, EMC-preferred type, meter marking

Technical data Cable structure Properties


Control cable of special-PVC to UL CSA Bare copper, extra fine wire conductors, The materials used in manufacture are
AWM I/II A/B Style 2587 to DIN VDE 0295 cl.6 col. 4, BS 6360 cl.5 cadmium-free and contain no silicone
(sheath insulation) and CSA and IEC 60228 cl.6 and free from substances harmful to
Temperature range Core insulation of special PVC the wetting properties of lacquers
flexing -5C to +90C compound type YI8 to Tests
fixed installation -40C to +90C DIN VDE 0207 part 4 and class 43 PVC self-extinguishing and flame retardant
(up to +105C for short time) acc. to UL-Std.1581 acc. to DIN VDE 0482-332-1-2,
Nominal voltage Core identification to DIN VDE 0293 DIN EN 60332-1-2, IEC 60332-1 (equivalent
UL/CSA 600 V red cores with continuous white DIN VDE 0472 part 804 test method B),
Test voltage 4000 V numbering UL VW-1, CSA FT1
Breakdown voltage min. 8000 V GN-YE conductor in the outer layer UV-resistant
Insulation resistance Cores stranded with optimal lay-length
min 20 MOhm x km Core wrapping with fleece over each layer Note
Minimum bending radius PVC-inner sheath G = with green-yellow conductor
flexing 10x cable Screening: braid coverage ca. 85% AWG sizes are approximate equivalent
fixed installation 5x cable up to 17 mm - layer of tinned copper values. The actual cross-section is in mm.
Radiation resistance wires unscreened analogue type:
up to 80x106 cJ/kg (up to 80 Mrad) >17 mm - tinned copper wire JZ-602 RC, confer page 423
Coupling resistance Outer sheath of special PVC
max. 250 Ohm/km compound type YM5 to
DIN VDE 0207 part 5, UL-Style 2587 and
CSA C22.2 No 210
Outer sheath black (RAL 9005)
with meter marking

Application
These cable are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms. These special cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics, for
movable automated machinery parts. These cables have shown excellent performance in combination with standard cable trays. The dense screening
assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above applications. Interesting for N
the export-oriented machines and machinery plants. For applications which go beyond standard solutions we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for
drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
89950 3 G 0,5 20 8,5 45,0 124,0 89976 25 G 1,5 16 25,2 544,0 950,0
89951 4 G 0,5 20 9,0 52,0 135,0 89977 34 G 1,5 16 28,1 674,0 1203,0
89952 5 G 0,5 20 9,7 68,0 153,0 89984 3 G 2,5 14 11,8 141,0 220,0
89953 7 G 0,5 20 11,0 93,0 191,0 89978 4 G 2,5 14 13,2 170,0 270,0
89954 9 G 0,5 20 12,4 134,0 243,0 89985 5 G 2,5 14 14,2 195,0 350,0
89955 12 G 0,5 20 13,5 163,0 322,0 89979 7 G 2,5 14 17,4 251,0 428,0
89956 15 G 0,5 20 14,8 174,0 350,0 89986 12 G 2,5 14 21,0 368,0 730,0
89957 18 G 0,5 20 16,0 191,0 374,0 89980 18 G 2,5 14 25,4 639,0 1140,0
89958 25 G 0,5 20 19,0 223,0 436,0 89987 3G4 12 14,0 180,0 296,0
89959 3G1 18 8,9 56,0 130,0 89981 4G4 12 15,9 232,0 456,0
89960 4G1 18 9,7 81,0 155,0 89988 5G4 12 17,7 330,0 450,0
89961 5G1 18 10,4 90,0 181,0 89982 7G4 12 20,9 395,0 737,0
89962 7G1 18 12,0 106,0 208,0 89983 4G6 10 18,3 316,0 572,0
89963 9G1 18 14,1 161,0 321,0 89989 4 G 10 8 23,2 490,0 1012,0
89964 12 G 1 18 15,2 175,0 341,0 89990 4 G 16 6 27,6 850,0 1400,0
89965 15 G 1 18 16,7 204,0 396,0 89991 4 G 25 4 33,1 1450,0 2100,0
89966 18 G 1 18 17,6 241,0 473,0 89992 4 G 35 2 37,8 1890,0 2550,0
89967 25 G 1 18 20,7 342,0 650,0
89968 34 G 1 18 24,3 434,0 781,0
89969 3 G 1,5 16 10,2 89,0 165,0
89970 4 G 1,5 16 11,0 97,0 192,0
89971 5 G 1,5 16 11,8 111,0 224,0
89972 7 G 1,5 16 14,0 147,0 274,0
89973 9 G 1,5 16 16,4 193,0 340,0
89974 12 G 1,5 16 17,1 256,0 461,0
89975 18 G 1,5 16 20,2 360,0 674,0

Dimensions and specifications may be changed without prior notice. (RN05)

427
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA

MULTIFLEX 600-C highly-flexible, oil-resistant, screened,


EMC-preferred type, control cable for open installation TC-ER, PLTC-ER, NFPA
79 Edition 2012

Technical data Cable structure Properties


Highly-flexible PVC control cable acc. to Bare copper conductor, extra-fine wire Self-extinguishing and flame retardant in
UL-Std.1277 stranded, with AWG measures acc. to CSA FT4
Temperature range Core insulation of special PVC The materials used in manufacture are
flexing -5C to +90C with transparent nylon skin cadmium-free and contain no silicone
fixed installation -40C to +90C Core identification to DIN VDE 0293 and free from substances harmful to
Nominal voltage black cores with continuous white the wetting properties of lacquers
TC 600 V numbering UV-resistant
TC Wind Turbine (WTTC) 1000 V GN-YE conductor, 3 cores and above Tests
Test voltage 3000 V in the outer layer UL:
Coupling resistance Cores stranded in layers with TC-ER, PLTC-ER (AWG 18 - AWG 12),
max. 250 Ohm/km optimal lay-lengths ITC-ER (AWG 18 - AWG 12), MTW,
Minimum bending radius Separating foil NFPA 79 2012, WTTC 1000 V, DP-1,
flexing 10x cable Braided screening of tinned copper wires, OIL RES I&II, 90C dry / 75C wet,
Insulation resistance coverage approx. 85% Class 1 Div. 2 per NEC Art 336, 392, 501,
min. 20 MOhm x km Separator crush impact test in accordance
Radiation resistance Outer sheath of special PVC with UL 1277
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour black (RAL 9005) CSA:
with length marking in feet c(UL) CIC-TC FT4, CSA AWM I/II A/B FT4

Note
Advantages
Highly-flexible, simple installation
Available on request
with blue cores (DC)
with red cores (AC)
Grey or TPE outer sheath

Application
HELUKABEL MULTIFLEX 600-C is a highly-flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this
cable to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 edition 2012. Approved for open, unprotected
installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life; for industrial applications in dry,
damp and wet environments. Recommended applications: Production lines, bottling plants, machine construction, switch cabinets, conveyor systems,
packaging machines, automotive industry. For the use in energy drag chains please note the installation guidelines.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
62556 2 x 0,5 20 7,7 30,0 80,0 62580 18 G 1,5 16 18,4 376,0 559,0
62557 3 G 0,5 20 8,0 37,0 85,0 62581 25 G 1,5 16 23,1 510,0 788,0
62558 4 G 0,5 20 8,7 46,0 100,0 62582 34 G 1,5 16 25,8 674,0 1203,0
62559 5 G 0,5 20 9,3 54,0 113,0 62583 3 G 2,5 14 10,3 141,0 218,0
62560 7 G 0,5 20 10,7 70,0 152,0 62584 4 G 2,5 14 11,5 149,0 222,0
62561 12 G 0,5 20 12,3 112,0 210,0 62585 5 G 2,5 14 12,4 195,0 350,0
62562 18 G 0,5 20 15,1 153,0 304,0 62586 7 G 2,5 14 15,4 243,0 373,0
62563 25 G 0,5 20 18,1 225,0 408,0 62587 9 G 2,5 14 16,8 312,0 479,0
62564 34 G 0,5 20 19,8 267,0 530,0 62588 12 G 2,5 14 18,5 368,0 730,0
62565 3 G 0,75 18 8,5 55,0 101,0 62589 18 G 2,5 14 22,4 639,0 1140,0
62566 4 G 0,75 18 9,3 69,0 127,0 62590 25 G 2,5 14 25,5 796,0 1530,0
62567 5 G 0,75 18 10,0 82,0 148,0 62591 3G4 12 11,7 180,0 296,0
62568 7 G 0,75 18 11,6 119,0 186,0 62592 4G4 12 13,3 221,0 305,0
62569 12 G 0,75 18 14,1 178,0 286,0 62593 5G4 12 14,7 330,0 450,0
62570 15 G 0,75 18 15,2 175,0 455,0 62594 7G4 12 17,8 363,0 536,0
62571 18 G 0,75 18 16,3 252,0 383,0 62595 4G6 10 16,1 314,0 469,0
62572 25 G 0,75 18 19,6 362,0 514,0 62596 5G6 10 17,5 441,0 772,0
62573 34 G 0,75 18 21,9 473,0 685,0 62597 7G6 10 20,6 505,0 1028,0
62574 3 G 1,5 16 9,3 75,0 131,0 62598 4 G 10 8 21,9 526,0 790,0
62575 4 G 1,5 16 10,2 93,0 165,0 62599 5 G 10 8 24,1 610,0 1096,0
62576 5 G 1,5 16 11,0 113,0 195,0 62600 4 G 16 6 24,8 730,0 1621,0
62577 7 G 1,5 16 12,9 162,0 250,0 62602 5 G 16 6 27,2 1050,0 1759,0
62578 9 G 1,5 16 15,2 193,0 340,0 62603 4 G 25 4 33,1 1450,0 2100,0
62579 12 G 1,5 16 15,6 249,0 393,0 62605 4 G 35 2 37,8 1840,0 2550,0

Dimensions and specifications may be changed without prior notice. (RN01)

428
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA

MULTISPEED 500-C-PVC UL/CSA oil resistant, high


flexible, safety against high bending in drag chain systems, low torsion, screened,
EMC-preferred type, meter marking

Technical data Cable structure Properties


Special drag chain cables for high Bare copper, fine wire conductors, The materials used in manufacture are
mechanical stress in accordance to Unilay with short pitch length cadmium-free and contain no silicone
DIN VDE 0285-525-2-51/DIN EN Core insulation of Special PP and free from substances harmful to
50525-2-51 Core identification to DIN VDE 0293 the wetting properties of lacquers
and UL-Std.758 AWM Style 21179 black cores with continuous white Tests
Temperature range numbering PVC self-extinguishing and flame retardant
flexing -5C to +80C GN-YE conductor, 3 cores and above acc. to DIN VDE 0482-332-1-2,
fixed installation -30C to +80C Stranding: DIN EN 60332-1-2, IEC 60332-1 (equivalent
Nominal voltage <7 cores: with optimal lay length, DIN VDE 0472 part 804
VDE U0/U 300/500 V construction due to a filling element, in a test method B), UL VW-1, CSA FT1
UL 600 V stranded position Low adhesion
Test voltage 3000 V 7 cores: cores stranded with optimal Ozon and UV resistant
Insulation resistance lay-length to bunch-construction with low High property of alternating bending
min. 100 MOhm x km torsion strength, optimal selected short strength
Minimum bending radius lay-length around a filler longer service life due to low
flexing 7,5x cable Special PVC inner sheath YM2 gusset-filling friction resistance
fixed installation 4x cable extruded, grey (RAL 7001) Better chemical resistance
Coupling resistance Braid of tinned copper wires, minimum Oil resistance to DIN VDE 0473-811-404/
max. 250 Ohm x km coverage 85% max. with optimal braiding DIN EN 60811-404
Radiation resistance pitch Higher stability
up to 80x106 cJ/kg (up to 80 Mrad) Outer sheath of special PVC Higher economical solution
especially fatigue resistant Reduced , therefore less moving masses
sheath colour black (RAL 9005)
with meter marking Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm. N
unscreened analogue type:
MULTISPEED 500-PVC UL/CSA,
confer page 425

Application
For permanently use on long distances, and high or low speeds. These high flexible PVC control cables are suitable for shift- and bending stresses in
machines and machine tool constructions. These are installed in dry, moist rooms and in open air with free movement without tensile stress or forced
movements. These screened cables are particularly suitable for the interference-free transmission in instrumentation and control engineering applications.
For applications which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems. Before
installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24335 2 x 0,5 20 6,6 30,0 88,0 24352 3G1 18 7,7 59,0 131,0
24336 3 G 0,5 20 6,9 36,0 101,0 24353 4G1 18 8,3 70,0 164,0
24337 4 G 0,5 20 7,3 42,0 116,0 24354 5G1 18 9,1 84,0 198,0
24338 5 G 0,5 20 7,8 48,0 146,0 24355 7G1 18 14,0 106,0 252,0
24339 7 G 0,5 20 11,3 64,0 181,0 24356 12 G 1 18 15,0 174,0 410,0
24340 9 G 0,5 20 11,4 80,0 219,0 24357 18 G 1 18 18,7 240,0 550,0
24341 12 G 0,5 20 12,6 105,0 271,0 24358 25 G 1 18 21,2 332,0 756,0
24342 18 G 0,5 20 15,0 137,0 374,0 24359 3 G 1,5 16 8,6 75,0 166,0
24343 25 G 0,5 20 17,1 210,0 542,0 24360 4 G 1,5 16 9,4 90,0 199,0
24344 2 x 0,75 19 6,8 40,0 96,0 24361 5 G 1,5 16 10,4 108,0 229,0
24345 3 G 0,75 19 7,4 48,0 111,0 24362 7 G 1,5 16 16,0 157,0 304,0
24346 4 G 0,75 19 8,0 55,0 140,0 24363 12 G 1,5 16 17,6 240,0 502,0
24347 5 G 0,75 19 8,5 66,0 161,0 24364 18 G 1,5 16 21,3 355,0 709,0
24348 7 G 0,75 19 12,9 85,0 227,0 24365 25 G 1,5 16 24,8 448,0 939,0
24349 12 G 0,75 19 14,4 135,0 317,0 24366 4 G 2,5 14 11,3 134,0 270,0
24350 18 G 0,75 19 17,5 190,0 486,0 24367 5 G 2,5 14 12,3 175,0 335,0
24351 25 G 0,75 19 19,9 275,0 651,0

Dimensions and specifications may be changed without prior notice. (RN05)

429
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

JZ-602 RC-PUR special cable for drag chains, 80C, 600 V, two
approval control cable, meter marking

Technical data Cable structure Properties


Control cable of special-PUR to UL CSA Bare copper-conductor, to Resistant to mineral oils, synthetic oils and
AWM I/II A/B Style 20939 (sheath insulation) DIN VDE 0295 cl.6, extra fine-wire, coolant, UV-radiation, oxygene, ozon
and CSA BS 6360 cl.6, IEC 60228 cl.6 and hydrolysis. Conditionally resistant to
Temperature range Core insulation of special PVC microbes.
flexing -5C to +80C compound type TI2 to The materials used in manufacture are
fixed installation -40C to +80C DIN VDE 0207-363-3 / DIN EN 50363-3 cadmium-free and contain no silicone
Nominal voltage UL/CSA 600 V and class 43 to UL-Std.1581 and free from substances harmful to
Test voltage 4000 V Core identification to DIN VDE 0293 the wetting properties of lacquers
Breakdown voltage min. 8000 V black cores with continuous white
Insulation resistance numbering Note
min 20 MOhm x km GN-YE conductor in the outer layer G = with green-yellow conductor
Minimum bending radius Cores stranded in layers with optimal AWG sizes are approximate equivalent
flexing 7,5x cable selected lay-lenght values. The actual cross-section is in mm.
fixed installation 4x cable Core wrapping with fleece over each layer screened analogue type:
Radiation resistance Outer sheath of special full-polyurethane JZ-602 RC -C-PUR, confer page 436
up to 100x106 cJ/kg (up to 100 Mrad) Sheath colour grey (RAL 7001)
with meter marking

Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist,
wet rooms and outdoor. These special cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics,
for movable automated machinery parts. For applications which go beyond standard solutions (for example for composting appliances or high shelf
conveyors with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before
installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12630 3 G 0,5 20 6,0 14,0 58,0 12656 25 G 1,5 16 19,8 360,0 625,0
12631 4 G 0,5 20 6,5 19,0 69,0 12657 34 G 1,5 16 22,4 490,0 840,0
12632 5 G 0,5 20 7,1 24,0 84,0 12658 3 G 2,5 14 8,9 72,0 150,0
12633 7 G 0,5 20 8,2 34,0 123,0 12659 4 G 2,5 14 10,1 96,0 185,0
12634 9 G 0,5 20 10,0 43,2 177,0 12660 5 G 2,5 14 11,3 120,0 242,0
12635 12 G 0,5 20 10,5 58,2 192,0 12661 7 G 2,5 14 13,6 168,0 293,0
12636 18 G 0,5 20 12,5 86,0 256,0 12662 12 G 2,5 14 16,8 288,0 498,0
12637 25 G 0,5 20 15,2 120,0 358,0 12663 3G4 12 10,9 115,0 231,0
12638 34 G 0,5 20 17,1 163,0 487,0 12664 4G4 12 12,4 154,0 298,0
12639 3 G 0,75 18 6,6 23,8 88,0 12665 5G4 12 13,8 192,0 370,0
12640 4 G 0,75 18 7,1 31,7 101,0 12666 7G4 12 16,6 269,0 460,0
12641 5 G 0,75 18 7,8 39,6 126,0 12667 4G6 10 14,6 231,0 430,0
12642 7 G 0,75 18 9,2 55,4 145,0 12668 4 G 10 8 18,2 384,0 720,0
12643 9 G 0,75 18 11,0 86,4 168,0 12669 4 G 16 6 22,6 615,0 1060,0
12644 12 G 0,75 18 11,5 95,0 260,0 12670 4 G 25 4 26,5 960,0 1590,0
12645 15 G 0,75 18 13,2 119,0 300,0 12671 4 G 35 2 30,8 1344,0 2105,0
12646 18 G 0,75 18 14,0 142,4 360,0
12647 25 G 0,75 18 17,2 197,8 640,0
12648 34 G 0,75 18 19,1 269,0 730,0
12649 3 G 1,5 16 7,4 44,0 94,0
12650 4 G 1,5 16 8,0 58,0 117,0
12651 5 G 1,5 16 8,8 72,0 140,0
12652 7 G 1,5 16 10,8 101,0 186,0
12653 9 G 1,5 16 12,8 129,7 244,0
12654 12 G 1,5 16 13,5 173,0 319,0
12655 18 G 1,5 16 16,0 260,0 451,0

Dimensions and specifications may be changed without prior notice. (RN05)

430
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

MULTIFLEX 512-PUR UL/CSA special cable for drag


chains, 80C, 600 V, two approval control cable, halogen-free

Technical data Cable structure Properties


Special drag chain cables for high Bare copper, extra fine wire conductors, Very good oil resistant
mechanical stress, acc. to bunch stranded to DIN VDE 0295 cl.6, Guaranteed permanent application in
UL Style 20939 col. 4, BS 6360 cl.6 and IEC 60228 cl.6 multi-shift operation under extreme high
Temperature range Core insulation of special PP bending stress
flexing -30C to +80C Core identification to DIN VDE 0293 Adhesion-low
fixed installation -40C to +80C black cores with continuous white High resistance to mechanical strain
Nominal voltage UL/CSA 600 V numbering High property of alternating bending
Test voltage 3000 V GN-YE conductor, 3 cores and above strength
Insulation resistance in the outer layer Long life durabilities through low
min. 100 MOhm x km Cores stranded in layers with optimal friction-resistance by using the TP
Minimum bending radius selected lay-length insulation
flexing 5x cable Special core wrapping over each layer (up High tensile strength-, abrasion- and
fixed installation 3x cable to 4 mm without core wrapping over the impact resistant at pw temperature
Alternating bending test outer layer) Resistant to weather, ozone and
tested with approx. 10 million Outer sheath of special full-polyurethane UV-radiation, solvents, acids and alkalis,
bending cycles TMPU, to DIN VDE 0207-363-10-2/ and hydrolysis
Radiation resistance DIN EN 50363-10-2 PUR outer sheath self-extinguishing and
up to 50x106 cJ/kg (up to 50 Mrad) Sheath colour grey (RAL 7001) flame retardant acc. to
with meter marking DIN VDE 0482-332-1-2, DIN EN
60332-1-2/
IEC 60332-1 (equivalent DIN VDE 0472
part 804 test method B) UL VW-1, CSA FT1

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
N
when ordering.
screened analogue type:
MULTIFLEX 512 -C-PUR UL/CSA,
confer page 437

Application
These special UL/CSA cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics, for movable
automated machinery parts and multi-shift operation. Those cables are developed according to the newest state of technology improvement. These
high flexible control cables with sliding abilities guaranteed an optimum service life durabilities and also very economic by using the PP-core insulation
and the PUR-outer sheath. The PUR material is adhesion-low and cut-resistant. For applications which go beyond standard solutions (for example for
composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet
for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain
cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
21559 2 x 0,5 20 5,5 9,6 38,0 21570 2 x 0,75 19 6,2 14,4 47,0
21560 3 G 0,5 20 5,8 14,4 46,0 21571 3 G 0,75 19 6,5 21,6 58,0
21561 4 G 0,5 20 6,4 19,0 59,0 21572 4 G 0,75 19 7,0 29,0 69,0
21562 5 G 0,5 20 7,0 24,0 68,0 21573 5 G 0,75 19 7,8 36,0 85,0
21563 7 G 0,5 20 8,1 33,6 88,0 21574 7 G 0,75 19 9,0 50,0 118,0
21564 12 G 0,5 20 9,9 58,0 131,0 21575 12 G 0,75 19 11,0 86,0 183,0
21565 18 G 0,5 20 11,5 86,0 197,0 21576 18 G 0,75 19 13,0 130,0 270,0
21566 20 G 0,5 20 12,0 96,0 260,0 21577 20 G 0,75 19 13,5 144,0 290,0
21567 25 G 0,5 20 13,7 120,0 282,0 21578 25 G 0,75 19 15,4 180,0 374,0
21568 30 G 0,5 20 14,3 144,0 315,0 21579 30 G 0,75 19 16,2 216,0 420,0
21569 36 G 0,5 20 15,3 172,0 374,0 21580 36 G 0,75 19 17,6 259,0 498,0

Continuation

431
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

MULTIFLEX 512-PUR UL/CSA special cable for drag


chains, 80C, 600 V, two approval control cable, halogen-free
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
21581 2x1 18 6,9 19,2 55,0 21609 2 x 2,5 14 9,2 48,0 115,0
21582 3G1 18 7,4 29,0 70,0 21610 3 G 2,5 14 9,7 72,0 162,0
21583 4G1 18 8,0 38,0 86,0 21611 4 G 2,5 14 10,5 96,0 196,0
21584 5G1 18 8,7 48,0 102,0 21612 5 G 2,5 14 11,6 120,0 230,0
21585 7G1 18 10,2 67,0 143,0 21613 7 G 2,5 14 13,8 168,0 312,0
21586 12 G 1 18 12,6 115,0 225,0 21614 12 G 2,5 14 16,9 288,0 532,0
21587 18 G 1 18 14,8 173,0 334,0 21615 18 G 2,5 14 20,0 432,0 762,0
21588 20 G 1 18 15,8 192,0 370,0 21616 20 G 2,5 14 21,2 480,0 858,0
21589 25 G 1 18 18,1 240,0 460,0 21617 25 G 2,5 14 24,4 600,0 998,0
21590 30 G 1 18 18,5 288,0 530,0 21618 4G4 12 13,2 154,0 283,0
21591 36 G 1 18 20,1 346,0 625,0 21619 5G4 12 14,6 192,0 349,0
21592 41 G 1 18 22,0 410,0 779,0 21620 7G4 12 17,6 79,0 498,0
21593 50 G 1 18 24,0 498,0 953,0 21621 4G6 10 14,4 230,0 432,0
21594 65 G 1 18 27,2 650,0 1205,0 21622 5G6 10 15,9 288,0 529,0
21595 2 x 1,5 16 7,6 29,0 70,0 21623 7G6 10 19,2 403,0 782,0
21596 3 G 1,5 16 8,1 43,0 90,0 21624 4 G 10 8 18,4 384,0 685,0
21597 4 G 1,5 16 8,7 58,0 106,0 21625 5 G 10 8 20,7 480,0 817,0
21598 5 G 1,5 16 9,7 72,0 145,0 21626 7 G 10 8 24,7 672,0 1023,0
21599 7 G 1,5 16 11,3 101,0 205,0 21627 4 G 16 6 21,3 614,0 1042,0
21600 12 G 1,5 16 13,8 173,0 320,0 21628 5 G 16 6 23,8 768,0 1292,0
21601 18 G 1,5 16 16,3 259,0 465,0 21629 7 G 16 6 28,6 1075,0 1709,0
21602 20 G 1,5 16 17,3 288,0 510,0
21603 25 G 1,5 16 19,8 360,0 650,0
21604 30 G 1,5 16 20,3 432,0 750,0
21605 36 G 1,5 16 22,2 518,0 880,0
21606 42 G 1,5 16 24,0 628,0 1209,0
21607 50 G 1,5 16 26,2 749,0 1449,0
21608 61 G 1,5 16 28,9 912,0 1712,0

Dimensions and specifications may be changed without prior notice. (RN05)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

432
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

MULTISPEED 500-PUR UL/CSA safety against high


bending in drag chain systems, low torsion, halogen-free, meter marking

Technical data Cable structure Properties


Special drag chain cables for high Bare copper, fine wire conductors, The materials used in manufacture are
mechanical stress in adapted to unilay with short pitch length cadmium-free and contain no silicone
DIN VDE 0285-525-2-51/ Core insulation of special PP and free from substances harmful to
DIN EN 50525-2-51, Core identification to DIN VDE 0293 the wetting properties of lacquers
DIN VDE 0285-525-2-21/ black cores with continuous white Tests
DIN EN 50525-2-21 numbering PUR-sheath flame retardant acc. to
and UL-Std.758 AWM Style 20939 GN-YE conductor, 3 cores and above DIN VDE 0482-332-1-2,
Temperature range Stranding: DIN EN 60332-1-2/IEC 60332-1
flexing -30C to +80C <7 cores: cores stranded in a layer with (equivalent DIN VDE 0472 part 804
fixed installation -40C to +80C optimal lay-length around a filler as per test method B), UL VW-1, CSA FT1
Nominal voltage contruction low adhesion
DIN VDE U0/U 300/500 V 7 cores: cores stranded with optimal halogen-free
UL 600 V lay-length to bunch-construction with low Higher economical solution
Test voltage 3000 V torsion strength, optimal selected short High resistant to mechanical strain
Insulation resistance lay-length around a filler Long life durabilitys due to low
min. 100 MOhm x km Outer sheath of special-PUR friction-resistance
Minimum bending radius extruded as filler with pressure High tensile strenght, abrasion- and impact
flexing 7,5x cable Sheath colour black (RAL 9005) resistance at low temperature
fixed installation 4x cable with meter marking Tear resistance
Radiation resistance Hight stability
up to 100x106 cJ/kg (up to 100 Mrad) Oil resistance
Better chemical resistance
UV and ozone resistance
Increased economic efficiency
Reduced , therefore less moving masses

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
N
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED 500-C-PUR UL/CSA,
confer page 439

Application
UL/CSA approved HELUKABEL MULTISPEED 500-PUR are installed there, where the extreme requirements for the cables are necessary. The selected
materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high an slow speed of
movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without tensile stress or forced movements.
These robust and abrasion resistant special control cables are installed there, where the problems appear for the application in permanent stresses e.
g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent movable machinery parts for multi-shift
operation. These cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing
speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the
instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24370 2 x 0,5 20 4,8 9,6 41,0 24378 3 G 0,75 19 5,2 21,6 51,0
24371 3 G 0,5 20 5,1 14,4 48,0 24379 4 G 0,75 19 6,1 29,0 68,0
24372 4 G 0,5 20 5,5 19,0 62,0 24380 5 G 0,75 19 6,6 36,0 73,0
24373 5 G 0,5 20 6,0 24,0 70,0 24381 7 G 0,75 19 10,5 50,0 92,0
24374 7 G 0,5 20 9,1 33,6 88,0 24382 12 G 0,75 19 11,4 86,0 170,0
24375 12 G 0,5 20 10,0 58,0 131,0 24383 18 G 0,75 19 14,2 130,0 257,0
24376 18 G 0,5 20 12,2 86,0 204,0 24384 25 G 0,75 19 16,3 180,0 280,0
24377 25 G 0,5 20 14,3 120,0 266,0 24385 36 G 0,75 19 20,1 260,0 411,0
24386 42 G 0,75 19 22,2 302,0 608,0

Continuation

433
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

MULTISPEED 500-PUR UL/CSA safety against high


bending in drag chain systems, low torsion, halogen-free, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24387 3G1 18 5,9 29,0 59,0 24401 4 G 2,5 14 8,9 86,0 173,0
24388 4G1 18 6,4 38,0 71,0 24402 5 G 2,5 14 9,8 120,0 220,0
24389 5G1 18 7,0 48,0 84,0 24403 7 G 2,5 14 16,1 168,0 290,0
24390 7G1 18 11,2 67,0 111,0 24404 12 G 2,5 14 17,8 288,0 504,0
24391 12 G 1 18 12,3 115,0 200,0 24405 18 G 2,5 14 21,8 432,0 719,0
24392 18 G 1 18 15,1 173,0 286,0 24406 25 G 2,5 14 24,4 600,0 940,0
24393 25 G 1 18 17,6 240,0 370,0
24331 36 G 1 18 21,6 346,0 485,0
24394 3 G 1,5 16 6,7 43,0 81,0
24395 4 G 1,5 16 7,3 58,0 102,0
24396 5 G 1,5 16 8,0 72,0 121,0
24397 7 G 1,5 16 13,2 101,0 164,0
24398 12 G 1,5 16 15,0 173,0 293,0
24399 18 G 1,5 16 17,7 259,0 450,0
24400 25 G 1,5 16 20,5 360,0 631,0
24332 36 G 1,5 16 25,6 518,0 779,0

Dimensions and specifications may be changed without prior notice. (RN05)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

434
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

PUR-JZ-HF-FCP high flexible, cable for drag chains, oil resistant,


EMC-preferred type, meter marking

Technical data Cable structure Properties


Special PUR drag chain cable, extreme Bare copper, fine wire conductors, to self-extinguishing and flame retardant
flexibility acc. to UL/CSA AWM I/II A/B DIN VDE 0295 cl.5, BS 6360 cl.5 acc. to DIN VDE 0482-332-1-2,
Style 21223 and IEC 60228 cl.5 DIN EN 60332-1-2 / IEC 60332-1
Temperature range Core insulation of special PVC (equivalent DIN VDE 0472 part 804
flexing -5C to +80C acc. to UL-Std.1581 test method B), UL VW-1, CSA FT1
fixed installation -40C to +80C Core identification to DIN VDE 0293 Suitable for outdoor lying
Nominal voltage black cores with continuous white resistant to UV-radiation,oxygen,
VDE U0/U 300/500 V numbering Ozone,Hydrolyzeandmicrobes
UL/CSA 1000 V GN-YE conductor, 3 cores and above low adhesion
Test voltage 4000 V in the outer layer The materials used in manufacture are
Breakdown voltage min. 8000 V Cores stranded in layers with optimal cadmium-free and contain no silicone
Insulation resistance selected lay-length and free from substances harmful to
min. 20 MOhm x km Separating foil over each layer the wetting properties of lacquers
Minimum bending radius construction with Cu-screening, tinned, oil resistant to DIN VDE 0473-811-404 /
flexing 10x cable approx. 85% DIN EN 60811-404
fixed installation 5x cable Minimum coverage 85%
Coupling resistance Outer sheath of special full-polyurethane Note
max. 250 Ohm/km to DIN VDE 0207-363-10-2/ G = with green-yellow conductor
Radiation resistance DIN EN 50363-10-12 acc. to UL-Std.1581 x = without green-yellow conductor (OZ)
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour grey (RAL 7001) AWG sizes are approximate equivalent
with meter marking values. The actual cross-section is in mm.
analouge type:
JZ-602 RC-PUR

Application
UL/CSA approved, highly flexible, screened PUR drag-chain cable for laying in dry, damp, wet rooms and outside, with free movement and without
tensile load or forced movements, suitable for frequent lifting and bending stresses in the sector of machine manufacture and tool making. Thanks to
the high level of shielding density, a fault-free transmission of signals or impulses is ensured. The ideal control line, offering protection against
interference, for the above applications. Of interest for those machinery manufacturers, who are export orientated. For applications which go beyond
standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for
N
our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12944 2 x 0,5 20 6,0 35,0 46,0 12962 4G1 18 7,8 71,0 114,0
12945 3 G 0,5 20 6,3 42,0 56,0 12963 5G1 18 8,4 88,0 136,0
12946 4 G 0,5 20 6,8 47,0 64,0 12964 7G1 18 9,8 111,0 169,0
12947 5 G 0,5 20 7,4 56,0 77,0 12965 12 G 1 18 12,0 184,0 270,0
12948 7 G 0,5 20 8,5 69,0 104,0 12966 18 G 1 18 14,2 260,0 385,0
12949 12 G 0,5 20 10,1 108,0 158,0 12967 25 G 1 18 16,8 349,0 530,0
12950 18 G 0,5 20 11,7 145,0 229,0 12968 2 x 1,5 16 7,3 63,0 88,0
12951 25 G 0,5 20 14,0 240,0 320,0 12969 3 G 1,5 16 7,7 80,0 104,0
12952 2 x 0,75 19 6,4 40,0 59,0 12970 4 G 1,5 16 8,4 97,0 136,0
12953 3 G 0,75 19 6,8 52,0 68,0 12971 5 G 1,5 16 9,1 119,0 170,0
12954 4 G 0,75 19 7,3 60,0 82,0 12972 7 G 1,5 16 10,7 147,0 221,0
12955 5 G 0,75 19 7,9 71,0 101,0 12973 12 G 1,5 16 13,0 267,0 348,0
12956 7 G 0,75 19 9,2 91,0 150,0 12974 18 G 1,5 16 15,5 374,0 489,0
12957 12 G 0,75 19 11,0 142,0 212,0 12975 25 G 1,5 16 18,7 526,0 710,0
12958 18 G 0,75 19 13,0 212,0 305,0 12976 3 G 2,5 14 9,1 144,0 177,0
12959 25 G 0,75 19 15,8 281,0 430,0 12977 4 G 2,5 14 9,9 148,0 204,0
12960 2x1 18 6,8 50,0 71,0 12978 7 G 2,5 14 13,0 255,0 340,0
12961 3G1 18 7,2 60,0 90,0 12979 4G4 12 11,2 230,0 310,0

Dimensions and specifications may be changed without prior notice. (RN05)

435
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

JZ-602 RC-C-PUR special cable for drag chains, 80C, 600 V, two
approval control cable, EMC-preferred type, meter marking

Technical data Cable structure Properties


Control cable of special-PUR to Bare copper, extra fine wire conductors, Resistant to mineral oils, synthetic oils and
UL CSA AWM I/II A/B Style 20939 to DIN VDE 0295 cl.6, BS 6360 cl.6 and coolant, UV-radiation, oxygene, ozon
(sheath insulation) and CSA IEC 60228 cl.6 and hydrolysis. Conditionally resistant to
Temperature range Core insulation of special PVC microbes.
flexing -5C to +80C compound type TI2 to The materials used in manufacture are
fixed installation -40C to +80C DIN VDE 0207-363-3/ DIN EN 50363-3 cadmium-free and contain no silicone
Nominal voltage UL/CSA 600 V and class 43 acc. to UL-Std.1581 and free from substances harmful to
Test voltage 4000 V Core identification to DIN VDE 0293 the wetting properties of lacquers
Breakdown voltage min. 8000 V black cores with continuous white
Insulation resistance numbering Note
min 20 MOhm x km GN-YE conductor in the outer layer G = with green-yellow conductor
Minimum bending radius Cores stranded with optimal lay-length AWG sizes are approximate equivalent
flexing 10x cable Wrapped of fleece over each layer values. The actual cross-section is in mm.
fixed installation 5x cable PVC-inner sheath unscreened analogue type:
Coupling resistance Screening: JZ-602 RC PUR, confer page 430
max. 250 Ohm/km up to 17 mm - layer of tinned copper
Radiation resistance wires
up 100x106 cJ/kg (up to 100 Mrad) >17 mm - tinned copper wire braid
coverage ca. 85%
Outer sheath of special Full-polyurethane
Sheath colour grey (RAL 7001)
with meter marking

Application
These cable are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist,
wet rooms and outdoor. These special cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics,
for movable automated machinery parts. The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free
control cable for the above applications. For applications which go beyond standard solutions we recommend for our especially developed enquiry
sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for drag
chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12680 3 G 0,5 20 8,5 45,0 124,0 12706 25 G 1,5 16 25,2 544,0 950,0
12681 4 G 0,5 20 9,0 52,0 135,0 12707 34 G 1,5 16 28,1 674,0 1203,0
12682 5 G 0,5 20 9,7 68,0 153,0 12708 3 G 2,5 14 11,8 141,0 220,0
12683 7 G 0,5 20 11,0 93,0 191,0 12709 4 G 2,5 14 13,2 170,0 270,0
12684 9 G 0,5 20 12,4 134,0 243,0 12710 5 G 2,5 14 14,2 195,0 350,0
12685 12 G 0,5 20 13,5 163,0 322,0 12711 7 G 2,5 14 17,4 251,0 428,0
12686 15 G 0,5 20 14,8 174,0 350,0 12712 12 G 2,5 14 21,0 368,0 730,0
12687 18 G 0,5 20 16,0 191,0 374,0 12713 18 G 2,5 14 25,4 639,0 1140,0
12688 25 G 0,5 20 19,0 223,0 436,0 12714 3G4 12 14,0 180,0 296,0
12689 3 G 0,75 18 8,9 56,0 130,0 12715 4G4 12 15,9 232,0 456,0
12690 4 G 0,75 18 9,7 81,0 155,0 12716 5G4 12 17,7 330,0 450,0
12691 5 G 0,75 18 10,4 90,0 181,0 12717 7G4 12 20,9 395,0 737,0
12692 7 G 0,75 18 12,0 106,0 208,0 12718 4G6 10 18,3 316,0 572,0
12693 9 G 0,75 18 14,1 161,0 321,0 12719 4 G 10 8 23,2 490,0 1012,0
12694 12 G 0,75 18 15,2 175,0 341,0 12720 4 G 16 6 27,6 850,0 1400,0
12695 15 G 0,75 18 16,7 204,0 396,0 12721 4 G 25 4 33,1 1450,0 2100,0
12696 18 G 0,75 18 17,6 241,0 473,0 12722 4 G 35 2 37,8 1890,0 2550,0
12697 25 G 0,75 18 20,7 342,0 650,0
12698 34 G 0,75 18 24,3 434,0 781,0
12699 3 G 1,5 16 10,2 89,0 165,0
12700 4 G 1,5 16 11,0 97,0 192,0
12701 5 G 1,5 16 11,8 111,0 224,0
12702 7 G 1,5 16 14,0 147,0 274,0
12703 9 G 1,5 16 16,4 193,0 340,0
12704 12 G 1,5 16 17,1 256,0 461,0
12705 18 G 1,5 16 20,2 360,0 674,0

Dimensions and specifications may be changed without prior notice. (RN05)

436
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

MULTIFLEX 512-C-PUR UL/CSA special cable for


drag chains, 80C, 600 V, two approval control cable, EMC-preferred type,
halogen-free, meter marking

Technical data Cable structure Properties


Special drag chain cables for extreme Bare copper, extra fine wire conductors, Very good oil resistant
mechanical stress to UL-Style 20939 bunch stranded to DIN VDE 0295 cl.6, Guaranteed permanent application in
Temperature range col. 4, BS 6360 cl.6 and IEC 60228 cl.6 multi-shift operation under extreme high
flexing -30C to +80C Core insulation of special PP bending stress
fixed installation -40C to +80C Core identification to DIN VDE 0293 Adhesion-low
Nominal voltage UL/CSA 600 V black cores with continuous white High resistant to mechanical strain
Test voltage 3000 V numbering High property of alternating bending
Insulation resistance GN-YE conductor, 3 cores and above strength
min. 100 MOhm x km in the outer layer Long lifedurabilities through low
Minimum bending radius Cores stranded in layers with optimal fiction-resistance by using the TPE
flexing 7,5x cable selected lay-length insulation
fixed installation 4x cable Special core wrapping over each layers and High tensile strength-, abrasion and
Alternating bending test an additional fleece over outer layer impact resistant at low temperature
tested with approx. 10 million TPE-inner sheath, halogen-free Resistant to Weather, Ozone, UV-radiation,
bending cycles Wrapping with special tapes Solvents, Acids and Alkalis, Hydraulic
Radiation resistance Tinned copper braided screening, approx. liquidity and Hydrolysis
up to 50x106 cJ/kg (up to 50 Mrad) 85% coverage The materials used in manufacture are
Coupling resistance Special core wrapping of fleece (up to cadmium-free and contain no silicone
max. 250 Ohm/km 4 mm without core wrapping over the outer and free from substances harmful to
layer) the wetting properties of lacquers
Outer sheath of special full-polyurethane Tests
TMPU, to DIN VDE 0207-363-10-2 / PUR-sheath flame retardant acc. to
DIN EN 50363-10-2 DIN VDE 0482-332-1-2,
Sheath colour grey (RAL 7001) DIN EN 60332-1-2 / IEC 60332-1
with meter marking (equivalent DIN VDE 0472 part 804
test method B), UL VW-1, CSA FT1

Note
G = with green-yellow conductor
N
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
unscreened analogue type:
MULTIFLEX 512 PUR UL/CSA,
confer page 431

Application
The special screened UL/CSA cables for drag chains are mainly applied for impulse transmission to prevent external interference effects and used for
permanent flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts and multi-shift operation.
Those cables are developed according to the newest state of technology improvement. These high flexible control cables with sliding abilities guaranteed
an optimum service life durabilities and also very economic by using the PP-core insulation and the PUR-outer sheath which is adhesive-free and
cut-resistant.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
21630 2 x 0,5 20 8,3 30,0 90,0 21636 18 G 0,5 20 14,7 157,0 325,0
21631 3 G 0,5 20 8,5 38,0 105,0 21637 20 G 0,5 20 15,4 167,0 350,0
21632 4 G 0,5 20 9,0 50,0 124,0 21638 25 G 0,5 20 17,1 240,0 450,0
21633 5 G 0,5 20 9,7 65,0 132,0 21639 30 G 0,5 20 17,9 273,0 510,0
21634 7 G 0,5 20 11,1 70,0 175,0 21640 36 G 0,5 20 19,2 306,0 580,0
21635 12 G 0,5 20 12,7 100,0 250,0

Continuation

437
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

MULTIFLEX 512-C-PUR UL/CSA special cable for


drag chains, 80C, 600 V, two approval control cable, EMC-preferred type,
halogen-free, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
21641 2 x 0,75 19 8,8 39,0 110,0 21674 30 G 1,5 16 24,6 607,0 1025,0
21642 3 G 0,75 19 9,3 49,0 120,0 21675 36 G 1,5 16 26,4 702,0 1210,0
21643 4 G 0,75 19 9,7 60,0 148,0 21676 42 G 1,5 16 28,4 829,0 1441,0
21644 5 G 0,75 19 10,5 70,0 160,0 21677 50 G 1,5 16 31,2 1025,0 1709,0
21645 7 G 0,75 19 11,9 95,0 205,0 21678 61 G 1,5 16 34,2 1190,0 2025,0
21646 12 G 0,75 19 14,2 140,0 308,0 21679 2 x 2,5 14 11,9 104,0 198,0
21647 18 G 0,75 19 16,3 220,0 420,0 21680 3 G 2,5 14 12,6 140,0 284,0
21648 20 G 0,75 19 16,9 249,0 450,0 21681 4 G 2,5 14 13,6 164,0 378,0
21649 25 G 0,75 19 19,2 313,0 579,0 21682 5 G 2,5 14 14,7 190,0 423,0
21650 30 G 0,75 19 19,7 470,0 630,0 21683 7 G 2,5 14 17,4 236,0 486,0
21651 36 G 0,75 19 21,2 500,0 745,0 21684 12 G 2,5 14 20,9 390,0 756,0
21652 2x1 18 9,7 50,0 120,0 21685 18 G 2,5 14 24,2 607,0 1127,0
21653 3G1 18 10,0 60,0 135,0 21686 20 G 2,5 14 25,6 661,0 1210,0
21654 4G1 18 10,8 73,0 173,0 21687 25 G 2,5 14 29,1 796,0 1530,0
21655 5G1 18 11,7 81,0 187,0 21688 4G4 12 16,8 222,0 448,0
21656 7G1 18 13,4 114,0 240,0 21689 5G4 12 18,4 328,0 533,0
21657 12 G 1 18 16,0 186,0 360,0 21690 7G4 12 21,6 360,0 678,0
21658 18 G 1 18 18,5 254,0 498,0 21691 4G6 10 18,1 305,0 636,0
21659 20 G 1 18 19,4 322,0 568,0 21692 5G6 10 19,6 441,0 772,0
21660 25 G 1 18 21,7 377,0 670,0 21693 7G6 10 23,2 505,0 1028,0
21661 30 G 1 18 22,5 429,0 774,0 21694 4 G 10 8 22,5 485,0 1052,0
21662 36 G 1 18 24,3 516,0 895,0 21695 5 G 10 8 24,7 610,0 1096,0
21663 41 G 1 18 26,1 610,0 1032,0 21696 7 G 10 8 29,3 820,0 1530,0
21664 50 G 1 18 28,4 690,0 1160,0 21697 4 G 16 6 25,7 840,0 1386,0
21665 65 G 1 18 32,2 852,0 1660,0 21698 5 G 16 6 28,2 1050,0 1759,0
21666 2 x 1,5 16 10,2 64,0 145,0 21699 7 G 16 6 33,6 1510,0 2087,0
21667 3 G 1,5 16 11,0 84,0 168,0
21668 4 G 1,5 16 11,6 99,0 217,0
21669 5 G 1,5 16 12,6 129,0 235,0
21670 7 G 1,5 16 14,5 148,0 325,0
21671 12 G 1,5 16 17,4 279,0 481,0
21672 18 G 1,5 16 19,9 393,0 675,0
21673 25 G 1,5 16 23,7 584,0 927,0

Dimensions and specifications may be changed without prior notice. (RN05)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

438
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

MULTISPEED 500-C-PUR UL/CSA safety against


high bending in drag chain systems, low torsion, halogen-free, EMC-preferred type,
meter marking

Technical data Cable structure Properties


Special drag chain cables for high Bare copper, fine wire conductors, The materials used in manufacture are
mechanical stress in adapted to Unilay with short pitch length cadmium-free and contain no silicone
DIN VDE 0285-525-2-51/ Core insulation of special PP and free from substances harmful to
DIN EN 50525-2-51, Core identification to DIN VDE 0293 the wetting properties of lacquers
DIN VDE 0285-525-2-21/ black cores with continuous white Tests
DIN EN 50525-2-21 numbering PUR-sheath flame retardant acc. to
and UL-Std.758 AWM Style 20939 GN-YE conductor, 3 cores and above DIN VDE 0482-332-1-2,
Temperature range Stranding: DIN EN 60332-1-2 / IEC 60332-1
flexing -30C to +80C <7 cores: cores stranded in a layer with (equivalent DIN VDE 0472 part 804
fixed installation -40C to +80C optimal lay-length around a filler as pe test method B), UL VW-1, CSA FT1
Nominal voltage construction Low adhesion
VDE U0/U 300/500 V 7 cores: cores stranded with optimal High property of alternating bending
UL 600 V lay-length to bunch-construction with low strength
Test voltage 3000 V torsion strength, optimal selected short Longer service life due to low
Insulation resistance lay-length around a filler frictional resistance
min. 100 MOhm x km Special-TPE-O inner sheath, extruded as High tensile, abrasion and impact
Minimum bending radius filler with pressure, grey RAL 7001 resistance even at low temperatures
flexing 7,5x cable Tinned copper braided screen, coverage Higher notch toughness
fixed installation 4x cable 85% max., with optimal pitch Higher stability
Coupling resistant Outer sheath of special PUR Oil resistance
max. 250 Ohm/km Sheath colour black (RAL 9005) Better chemical resistance
Radiation resistance with meter marking UV and ozone resistance
up to 100x106 cJ/kg (up to 100 Mrad) Higher economical solution
Reduced , therefore less moving masses

Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ) N
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
MULTISPEED 500-PUR UL/CSA,
confer page 433

Application
UL/CSA approved HELUKABEL MULTISPEED 500-C-PUR is used in applications where extreme requirements placed on the line. Designed for the
export-orientated machinery manufacturer, specifically for USA and Canada. The selected materials and lay-up technique permit these high flexible
cables for permanent application in drag chains for long distances, high an slow speed of movements. These cables are installed in dry, moist and wet
rooms and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are
installed there, where the problems appear for the application in permanent stresses e. g. in energy drag chains, industry robotics, production lines,
automatic control systems and permanent movable machinery parts for multi-shift operation. These cables are installed everywhere, where high
requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary. These screened cables are particularly suitable for the
interference-free transmission in instrumentation and control engineering applications. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24410 2 x 0,5 20 6,6 30,0 90,0 24419 2 x 0,75 19 6,8 40,0 100,0
24411 3 G 0,5 20 6,9 36,0 104,0 24420 3 G 0,75 19 7,4 48,0 117,0
24412 4 G 0,5 20 7,3 42,0 118,0 24421 4 G 0,75 19 8,0 55,0 143,0
24413 5 G 0,5 20 7,8 48,0 148,0 24422 5 G 0,75 19 8,5 66,0 167,0
24414 7 G 0,5 20 11,3 64,0 184,0 24423 7 G 0,75 19 12,9 85,0 229,0
24415 9 G 0,5 20 11,4 80,0 219,0 24424 12 G 0,75 19 14,4 135,0 319,0
24416 12 G 0,5 20 12,6 105,0 276,0 24425 18 G 0,75 19 17,5 190,0 492,0
24417 18 G 0,5 20 15,0 137,0 378,0 24426 25 G 0,75 19 19,9 275,0 659,0
24418 25 G 0,5 20 17,5 210,0 547,0

Continuation

439
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

MULTISPEED 500-C-PUR UL/CSA safety against


high bending in drag chain systems, low torsion, halogen-free, EMC-preferred type,
meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24427 2x1 18 7,1 50,0 120,0 24436 4 G 1,5 16 9,4 90,0 204,0
24428 3G1 18 7,7 59,0 140,0 24437 5 G 1,5 16 10,4 108,0 236,0
24429 4G1 18 8,3 70,0 167,0 24438 7 G 1,5 16 16,0 157,0 309,0
24430 5G1 18 9,1 84,0 201,0 24439 12 G 1,5 16 17,6 240,0 509,0
24431 7G1 18 14,0 106,0 256,0 24440 18 G 1,5 16 21,3 355,0 718,0
24432 12 G 1 18 15,0 174,0 417,0 24441 25 G 1,5 16 24,8 448,0 944,0
24433 18 G 1 18 18,7 240,0 557,0 24334 36 G 1,5 16 30,3 592,0 1070,0
24434 25 G 1 18 21,4 332,0 766,0 24442 4 G 2,5 14 11,3 134,0 280,0
24333 36 G 1 18 26,1 436,0 840,0 24443 5 G 2,5 14 12,3 175,0 346,0
24435 3 G 1,5 16 8,6 75,0 170,0 24444 7 G 2,5 14 19,9 229,0 410,0

Dimensions and specifications may be changed without prior notice. (RN05)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

440
Cables according to international Approvals / TPE-Cables for Drag Chains UL/CSA

MULTISPEED 500-TPE UL/CSA high flexible,


safety against high bending in drag chain systems, low torsion, halogen-free,
meter marking

Technical data Cable structure Properties


Special drag chain cables for high Tinned copper, fine wire conductors Microbe-resistance - TPE
mechanical stress in acc. to Unilay with short pitch length High property of alternating bending
DIN VDE 0285-525-2-51/ Core insulation of special PP strength
DIN EN 50525-2-51 and UL-Std.758 Core identification to DIN VDE 0293 Long life durabilitys due to low
AWM Style 20841 and 21184 black cores with continuous white friction-resistance
Temperature range numbering High tensile strength, abrasion and impact
flexing -30C to +80C GN-YE conductor, 3 cores and above resistance at low temperature
fixed installation -40C to +80C Stranding: Extremely high bending loads
Nominal voltage <7 cores: cores stranded in a layer with Low adhesion
VDE U0/U 300/500 V optimal lay-length around a filler as per Halogen-free
UL 600 V construction Higher notch toughness
Test voltage 3000 V 7 cores: cores stranded with optimal Oil resistance
Insulation resistance lay-length to bunch-construction with low Better chemical resistance
min. 100 MOhm x km torsion strength, optimal selected short UV and ozone resistance
Minimum bending radius lay-length around a filler Higher economical solution
flexing 5x cable Outer sheath of special-TPE-O, Reduced , therefore less moving masses
fixed installation 3x cable extruded as filler with pressure The materials used in manufacture are
Radiation resistance Sheath colour ocean blue (RAL 5020) cadmium-free and contain no silicone
up to 100x106 cJ/kg (up to 100 Mrad) with meter marking and free from substances harmful to
TPE: The selected tinned copper wire the wetting properties of lacquers
conductor permits the installation in
aggressive environments as well as Note
hydrogen sulfide, ammonia and sulfur G = with green-yellow conductor
dioxide x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified" N
when ordering.
screened analogue type:
MULTISPEED 500-C-TPE UL/CSA,
confer page 443

Application
The selected materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high an slow
speed of movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without tensile stress or forced
movements. These robust and abrasion resistant special control cables are installed there, where the problems appear for the application in permanent
stresses e. g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent movable machinery parts for
multi-shift operation. These cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are
necessary. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please
read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24450 2 x 0,5 20 4,7 9,6 42,0 24458 2 x 0,75 19 5,0 14,4 47,0
24451 3 G 0,5 20 5,0 14,4 49,0 24459 3 G 0,75 19 5,2 21,6 55,0
24452 4 G 0,5 20 5,4 19,0 63,0 24460 4 G 0,75 19 6,1 29,0 70,0
24453 5 G 0,5 20 5,8 24,0 70,0 24461 5 G 0,75 19 6,6 36,0 74,0
24454 7 G 0,5 20 8,9 33,6 90,0 24462 7 G 0,75 19 10,5 50,0 95,0
24455 12 G 0,5 20 9,8 58,0 134,0 24463 12 G 0,75 19 11,4 86,0 174,0
24456 18 G 0,5 20 11,9 86,0 209,0 24464 18 G 0,75 19 14,2 130,0 261,0
24457 25 G 0,5 20 13,9 120,0 270,0 24465 25 G 0,75 19 16,3 180,0 290,0
24466 36 G 0,75 19 19,5 260,0 419,0
24467 42 G 0,75 19 21,3 302,0 614,0

Continuation

441
Cables according to international Approvals / TPE-Cables for Drag Chains UL/CSA

MULTISPEED 500-TPE UL/CSA high flexible,


safety against high bending in drag chain systems, low torsion, halogen-free,
meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24468 2x1 18 5,2 19,2 50,0 24479 7 G 1,5 16 13,2 101,0 169,0
24469 3G1 18 5,9 29,0 60,0 24480 12 G 1,5 16 14,4 173,0 299,0
24470 4G1 18 6,4 38,0 74,0 24481 18 G 1,5 16 17,7 259,0 460,0
24471 5G1 18 7,0 48,0 86,0 24482 25 G 1,5 16 19,8 360,0 640,0
24472 7G1 18 11,2 67,0 114,0 24483 4 G 2,5 14 8,9 96,0 179,0
24473 12 G 1 18 12,3 115,0 210,0 24484 5 G 2,5 14 9,8 120,0 230,0
24474 18 G 1 18 15,1 173,0 291,0 24485 7 G 2,5 14 16,1 168,0 294,0
24475 25 G 1 18 17,6 240,0 380,0 24486 12 G 2,5 14 17,8 288,0 510,0
24476 3 G 1,5 16 6,7 43,0 84,0 24487 18 G 2,5 14 21,8 432,0 722,0
24477 4 G 1,5 16 7,3 58,0 108,0 24488 25 G 2,5 14 24,4 600,0 950,0
24478 5 G 1,5 16 8,0 72,0 126,0

Dimensions and specifications may be changed without prior notice. (RN05)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

442
Cables according to international Approvals / TPE-Cables for Drag Chains UL/CSA

MULTISPEED 500-C-TPE UL/CSAsafetyagainst


high bending in drag chain systems, low torsion, halogen-free, EMC-preferred
type, meter marking

Technical data Cable structure Properties


Special drag chain cables for high Tinned copper, fine wire conductors, Microbe-resistance - TPE
mechanical stress in adapted to Unilay with short pitch length High property of alternating bending
DIN VDE 0285-525-2-51/ Core insulation of special PP strength
DIN EN 50525-2-51 and Core identification to DIN VDE 0293 Longer service life due to low friction
UL-Std.758 AWM Style 21184 black cores with continuous white resistance
Temperature range numbering High tensile, abrasion and impact
flexing -30C to +80C GN-YE conductor, 3 cores and above resistance even at low temperatures
fixed installation -40C to +80C Stranding: Extremely high bending loads
Nominal voltage <7 cores: cores stranded in a layer with Low adhesion
U0/U 300/500 V optimal lay-length around a filler as per Higher notch toughness
UL 600 V construction Oil resistance
Test voltage 3000 V 7 cores: cores stranded with optimal Better chemical resistance
Insulation resistance lay-length to bunch-construction with low UV and ozone resistance
min. 100 MOhm x km torsion strength, optimal selected short Higher economical solution
Minimum bending radius lay-length around a filler Reduced , therefore less moving masses
flexing 5x cable Special-TPE-O inner sheath, extruded as The materials used in manufacture are
fixed installation 3x cable filler with pressure, natural colour cadmium-free and contain no silicone
Coupling resistance Screen of Cu braid tinned, and free from substances harmful to
max. 250 Ohm x km coverage 85% max., with optimal pitch the wetting properties of lacquers
Radiation resistance Outer sheath of speciall-TPE-O
up to 100x106 cJ/kg (up to 100 Mrad) extruded as filler with pressure Note
Sheath colour ocean blue (RAL 5020) G = with green-yellow conductor
with meter marking x = without green-yellow conductor (OZ)
TPE: The selected tinned copper wire AWG sizes are approximate equivalent
conductor and tinned copper wire braid values. The actual cross-section is in mm.
permit the installation in aggressive Please note the cleanroom qualification
environments as well as hydrogen sulfide, when ordering.
ammonia and sulfur dioxide. unscreened analogue type: N
MULTISPEED 500-TPE UL/CSA,
confer page 441

Application
The selected materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and
slow speed of movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without tensile stress or forced
movements. These robust and abrasion resistant special control cables are installed there, where the problems appear for the application in permanent
stresses e. g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent movable machinery parts for
multi-shift operation. These cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are
necessary. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please
read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
23914 2 x 0,5 20 6,4 30,0 85,0 23923 2 x 0,75 19 7,0 40,0 97,0
23915 3 G 0,5 20 6,7 36,0 99,0 23924 3 G 0,75 19 7,4 48,0 110,0
23916 4 G 0,5 20 7,3 42,0 107,0 23925 4 G 0,75 19 8,0 55,0 139,0
23917 5 G 0,5 20 7,7 48,0 140,0 23926 5 G 0,75 19 8,5 66,0 160,0
23918 7 G 0,5 20 11,3 64,0 176,0 23927 7 G 0,75 19 12,9 85,0 219,0
23919 10 G 0,5 20 10,1 80,0 204,0 23928 12 G 0,75 19 14,4 135,0 307,0
23920 12 G 0,5 20 12,4 105,0 261,0 23929 18 G 0,75 19 17,2 190,0 490,0
23921 18 G 0,5 20 14,7 137,0 360,0 23930 25 G 0,75 19 19,9 275,0 640,0
23922 25 G 0,5 20 17,1 320,0 530,0

Continuation

443
Cables according to international Approvals / TPE-Cables for Drag Chains UL/CSA

MULTISPEED 500-C-TPE UL/CSAsafetyagainst


high bending in drag chain systems, low torsion, halogen-free, EMC-preferred
type, meter marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
23931 2x1 18 7,4 50,0 115,0 23941 5 G 1,5 16 10,4 108,0 220,0
23932 3G1 18 7,7 59,0 131,0 23942 7 G 1,5 16 16,0 157,0 294,0
23933 4G1 18 8,3 70,0 160,0 23943 12 G 1,5 16 17,6 240,0 490,0
23934 5G1 18 9,1 84,0 195,0 23944 18 G 1,5 16 21,3 355,0 704,0
23935 7G1 18 14,0 106,0 247,0 23945 25 G 1,5 16 24,8 448,0 930,0
23936 12 G 1 18 15,0 174,0 411,0 23946 4 G 2,5 14 11,3 134,0 260,0
23937 18 G 1 18 18,5 240,0 547,0 23947 5 G 2,5 14 12,3 175,0 330,0
23938 25 G 1 18 21,4 332,0 754,0 23948 7 G 2,5 14 14,8 229,0 406,0
23939 3 G 1,5 16 8,6 75,0 160,0 23949 12 G 2,5 14 21,5 390,0 990,0
23940 4 G 1,5 16 9,4 90,0 194,0

Dimensions and specifications may be changed without prior notice. (RN05)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

444
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA

SUPERTRONIC-310-PVC special cable for drag chains, meter


marking

Technical data Cable structure Properties


Special PVC drag chain cable Bare copper conductor, fine wire The materials used in manufacture are
acc. to UL-Style 2464 Unilay with short lay-lengths cadmium-free and contain no silicone
Temperature range Core insulation of PVC and free from substances harmful to
flexing -5C to +80C class 43 acc. to UL-Std.1581 the wetting properties of lacquers
fixed installation -40C to +80C Core identification to DIN 47100 Tests
Nominal voltage 300 V coloured PVC self-extinguishing and flame retardant
Test voltage 1500 V Cores stranded in layers with acc. to DIN VDE 0482-332-1-2,
Breakdown voltage min. 3000 V optimal lay-length DIN EN 60332-1-2, IEC 60332-1 (equivalent
Insulation resistance Wrapping of fleece between the DIN VDE 0472 part 804 test method B)
min. 20 MOhm x km layers of stranding Low-adhesion
Minimum bending radius Outer sheath of special PVC, oil resistant
flexing 5x cable compound type TM5 to Note
fixed installation 3x cable DIN VDE 0207-363-4-1/DIN EN 50363-4-1 Please observe applicable installation
Radiation resistance and class 43 acc. to UL-Std.1581 regulations for use in energy supply chains.
up to 80x106 cJ/kg (up to 80 Mrad) Sheath colour grey (RAL 7001) AWG sizes are approximate equivalent
with meter marking values. The actual cross-section is in mm.

Application
A highly-flexible PVC control cable suitable for frequent and fast lifting and bending stresses in machines and tool building, robot systems and on
constantly moving machine components. Long service lives guarantee reliable function and good cost efficiency. For applications which go beyond
standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for
our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text. Designed for machines intended for export, specifically USA and Canada.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
49885
49886
49887
2 x 0,14
3 x 0,14
4 x 0,14
26
26
26
3,7
3,9
4,1
2,8
4,1
5,6
24,0
26,0
31,0
49903
49904
49905
14 x 0,25
18 x 0,25
24 x 0,25
24
24
24
6,9
7,6
8,8
35,0
45,0
60,0
109,0
132,0
171,0
N
49888 5 x 0,14 26 4,5 7,0 36,0 49906 25 x 0,25 24 9,4 62,5 178,0
49889 7 x 0,14 26 5,1 9,8 50,0 49907 2 x 0,34 22 4,2 6,8 34,0
49890 10 x 0,14 26 5,8 14,0 65,0 49908 3 x 0,34 22 4,4 10,2 43,0
49891 12 x 0,14 26 6,0 16,8 72,0 49909 4 x 0,34 22 4,8 13,6 58,0
49892 14 x 0,14 26 6,2 19,6 78,0 49910 5 x 0,34 22 5,1 17,0 65,0
49893 18 x 0,14 26 6,9 25,2 91,0 49911 7 x 0,34 22 5,9 23,8 85,0
49894 24 x 0,14 26 7,8 33,6 120,0 49912 10 x 0,34 22 6,8 34,0 117,0
49895 25 x 0,14 26 8,3 35,0 125,0 49913 12 x 0,34 22 7,0 40,8 134,0
49896 2 x 0,25 24 4,0 5,0 29,0 49914 14 x 0,34 22 7,4 47,6 152,0
49897 3 x 0,25 24 4,2 7,5 34,0 49915 18 x 0,34 22 8,1 61,2 184,0
49898 4 x 0,25 24 4,5 10,0 40,0 49916 24 x 0,34 22 9,6 81,5 242,0
49899 5 x 0,25 24 4,9 12,5 51,0 49917 25 x 0,34 22 10,0 85,0 252,0
49900 7 x 0,25 24 5,6 17,5 65,0
49901 10 x 0,25 24 6,4 25,0 85,0
49902 12 x 0,25 24 6,6 30,1 97,0

Dimensions and specifications may be changed without prior notice. (RN05)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

445
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA

SUPERTRONIC-310-C-PVC special cable for drag chains,


EMC-preferred type, meter marking

Technical data Cable structure Properties


Special PVC drag chain cable Bare copper conductor, fine wire Low-adhesion
approved to UL-Style 2464 Unilay with short lay-lengths The materials used in manufacture are
Temperature range Core insulation of PVC cadmium-free and contain no silicone
flexing -5C to +80C class 43 acc. to UL-Std.1581 and free from substances harmful to
fixed installation -40C to +80C Core identification to DIN 47100 the wetting properties of lacquers
Nominal voltage 300 V coloured Tests
Test voltage Cores stranded in layers with PVC self-extinguishing and flame retardant
core/core 1500 V optimal lay-length acc. to DIN VDE 0482-332-1-2,
core/screen 1000 V Wrapping of fleece between the DIN EN 60332-1-2, IEC 60332-1 (equivalent
Breakdown voltage min. 3000 V layers of stranding DIN VDE 0472 part 804 test method B)
Minimum bending radius Wrapping over the outer layer
flexing 7,5x cable Braided screen of tinned Cu wires, Note
fixed installation 4x cable coverage approx. 85% Please observe applicable installation
Insulation resistance Core wrapping with fleece regulations for use in energy supply chains.
min. 20 MOhm x km Outer sheath of oil resistant special PVC, AWG sizes are approximate equivalent
Radiation resistance compound type TM5 to values. The actual cross-section is in mm.
up to 80x106 cJ/kg (up to 80 Mrad) DIN VDE 0281 Part 1 or
Coupling resistance class 43 acc. to UL-Std.1581
max. 250 Ohm/km Sheath colour grey (RAL 7001)
with meter marking

Application
A highly-flexible PVC control cable suitable for frequent and fast lifting and bending stresses in machines and tool building, robot systems and on
constantly moving machine components. Long service lives guarantee reliable function and good cost efficiency. The copper screen effectively protects
against internal and external interference. Designed for machines intended for export, specifically USA and Canada. For applications which go beyond
standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for
our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
49920 2 x 0,14 26 4,3 11,3 33,0 49938 14 x 0,25 24 7,6 64,3 138,0
49921 3 x 0,14 26 4,5 14,2 36,0 49939 18 x 0,25 24 8,3 78,6 165,0
49922 4 x 0,14 26 4,7 15,5 41,0 49940 24 x 0,25 24 9,7 89,8 200,0
49923 5 x 0,14 26 5,0 18,4 46,0 49941 25 x 0,25 24 10,1 101,2 204,0
49924 7 x 0,14 26 5,7 27,9 70,0 49942 2 x 0,34 22 4,8 18,2 44,0
49925 10 x 0,14 26 6,4 39,1 88,0 49943 3 x 0,34 22 5,0 28,8 60,0
49926 12 x 0,14 26 6,7 42,2 97,0 49944 4 x 0,34 22 5,4 35,8 76,0
49927 14 x 0,14 26 6,9 45,4 105,0 49945 5 x 0,34 22 5,7 39,2 80,0
49928 18 x 0,14 26 7,6 54,2 116,0 49946 7 x 0,34 22 6,6 52,8 104,0
49929 24 x 0,14 26 8,6 66,5 150,0 49947 10 x 0,34 22 7,5 67,5 150,0
49930 25 x 0,14 26 9,0 68,5 157,0 49948 12 x 0,34 22 7,7 76,5 160,0
49931 2 x 0,25 24 4,6 14,8 39,0 49949 14 x 0,34 22 8,1 85,9 180,0
49932 3 x 0,25 24 4,8 18,9 45,0 49950 18 x 0,34 22 8,9 99,9 211,0
49933 4 x 0,25 24 5,1 21,4 52,0 49951 24 x 0,34 22 10,3 147,0 290,0
49934 5 x 0,25 24 5,5 31,2 70,0 49952 25 x 0,34 22 10,9 155,0 304,0
49935 7 x 0,25 24 6,2 39,8 80,0
49936 10 x 0,25 24 7,1 53,9 114,0
49937 12 x 0,25 24 7,3 59,2 123,0

Dimensions and specifications may be changed without prior notice. (RN05)

Suitable Cable drag chains can be found


in our Cable Accessories catalogue.

446
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

SUPERTRONIC-330 PUR cable for drag chains,


halogen-free, meter marking

Technical data Cable structure Properties


Special PUR sheathed cable Bare copper, extra fine-wire to The materials used in manufacture are
Temperature range DIN VDE 0295 cl.6, col. 4, BS 6360 cl.6 cadmium-free and contain no silicone
flexing -30C to +80C Core insulation of PP and free from substances harmful to
fixed installation -40C to +80C Cores stranded in layers with optimally the wetting properties of lacquers
Nominal voltage 300 V lay-lengths Tests
Test voltage Core identification to DIN 47100 PUR outer sheath, flame retardant acc. to
core/core 1500 V coloured DIN VDE 0482-332-1-2,
Insulation resistance Wrapping over the outer layer DIN EN 60332-1-2/ IEC 60332-1 (equivalent
min. 100 MOhm x km Outer sheath of special full-polyurethane DIN VDE 0472 part 804 test method B)
Capacitance compound type TMPU to Low adhesion
core/core 60 nF/km DIN VDE 0282 Part 10, Annex A High flexibility at low temperatures
Minimum bending radius and acc. to UL-Std.1581 Tab.50227 High abrasion resistance
flexing 5x cable Sheath colour grey (RAL 7001) Tear and cut-resistant
fixed 3x cable with meter marking Notch resistant
Radiation resistance Resistant to
up to 100x106 cJ/kg (up to 100 Mrad) UV-radiation, Oxygen, Ozone, Hydrolysis,
Oil
Partially resistant to
Microbial attack, Hydraulic fluids, Coolant
emulsion, Alkalis

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
For installation in dry, moist and wet rooms and outdoors with free movement without tensile stress or forced movements, impressively proven in
drag chain application. A highly flexible PUR control cable, suitable for frequent and quick lifting and bending stresses in machine engineering and
construction, in robot technology and on permanently moving machine components. Long service life guarantees reliable function and high
cost-efficiency. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely
N
high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays
please read the instructions. Further technical details see selection table for drag chain cables, see lead text. Attractive for export-oriented mechanical
engineering.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
49764 2 x 0,14 26 3,9 2,8 22,0 49782 14 x 0,25 24 7,4 35,0 97,0
49765 3 x 0,14 26 4,0 4,1 24,0 49783 18 x 0,25 24 8,2 45,0 114,0
49766 4 x 0,14 26 4,3 5,6 29,0 49784 24 x 0,25 24 9,6 60,0 157,0
49767 5 x 0,14 26 4,7 7,0 33,0 49785 25 x 0,25 24 10,1 62,5 160,0
49768 7 x 0,14 26 5,3 9,8 47,0 49786 2 x 0,34 22 4,6 6,8 31,0
49769 10 x 0,14 26 6,1 14,0 57,0 49787 3 x 0,34 22 4,8 10,2 38,0
49770 12 x 0,14 26 6,2 16,8 63,0 49788 4 x 0,34 22 5,2 13,6 51,0
49771 14 x 0,14 26 6,5 19,6 72,0 49789 5 x 0,34 22 5,6 17,0 54,0
49772 18 x 0,14 26 7,2 25,2 80,0 49790 7 x 0,34 22 6,5 23,8 77,0
49773 24 x 0,14 26 8,2 33,6 110,0 49791 10 x 0,34 22 7,5 34,0 104,0
49774 25 x 0,14 26 8,6 35,0 115,0 49792 12 x 0,34 22 7,7 40,8 122,0
49775 2 x 0,25 24 4,3 5,0 26,0 49793 14 x 0,34 22 8,1 47,6 140,0
49776 3 x 0,25 24 4,5 7,5 30,0 49794 18 x 0,34 22 9,2 61,2 162,0
49777 4 x 0,25 24 4,8 10,0 39,0 49795 24 x 0,34 22 10,7 81,5 204,0
49778 5 x 0,25 24 5,2 12,5 44,0 49796 25 x 0,34 22 11,2 85,0 229,0
49779 7 x 0,25 24 6,0 17,5 52,0
49780 10 x 0,25 24 6,9 25,0 70,0
49781 12 x 0,25 24 7,1 30,1 84,0

Dimensions and specifications may be changed without prior notice. (RN05)

447
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

MULTISPEED-TRONIC-PUR safety against high bending


in drag chain systems, halogen-free, meter marking

Technical data Cable structure Properties


Special drag chain cables for high Bare copper, fine wire conductors, Unilay The materials used in manufacture are
mechanical stress in adapted to with short pitch length cadmium-free and contain no silicone
DIN VDE 0285-525-2-51/ Core insulation of special PP and free from substances harmful to
DIN EN 50525-2-51, Core identification to DIN 47100 the wetting properties of lacquers
DIN VDE 0285-525-2-21/ <7 cores: cores stranded in a layer with Tests
DIN EN 50525-2-21 optimal lay-length around a filler as per PUR outer sheath, flame retardant acc. to
and acc. to UL-Std.758 AWM, construction DIN VDE 0482-332-1-2,
Style 20233 7 cores: cores stranded with optimal DIN EN 60332-1-2/ IEC 60332-1 (equivalent
Temperature range lay-length to bunch-construction with low DIN VDE 0472 part 804 test method B)
flexing -30C to +80C torsion strength, optimal selected short UL VW-1, CSA FT1
fixed installation -40C to +80C lay-length around a filler Low-adhesion
Nominal voltage Outer sheath of special PUR extruded Halogen-free
U0/U 300/300 V extruded as filler with pressurea High property of alternating bending
Test voltage 3000 V Sheath colour black (RAL 9005) strength
Insulation resistance with meter marking High tensile strength, abrasion- and impact
min. 100 MOhm x km resistance at low temperature
Minimum bending radius Use in multi-shift operations under
flexing 7,5x cable extremely high continuous bending loads
fixed installation 4x cable Abrasion resistance
Radiation resistance Tear resistance
up to 100x106 cJ/kg (up to 100 Mrad) High stability
Oil resistance
Better chemical resistance
UV and ozone resistance
Higher economical solution
Reduced diameter, therefore lower moving
masses

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED-TRONIC-C-PUR,
confer page 450

Application
Application HELUKABEL MULTISPEED-TRONIC-PUR installed there, where the extreme requirements for the cables are necessary. The selected
materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and low speed of
movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without tensile stress or forced movements.
These robust and abrasion resistant special control cables are installed there, where the problems appear for the application in permanent stresses
e. g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent movable machinery parts for multi-shift
operation. These cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing
speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the
instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24567 2 x 0,25 24 3,9 5,0 27,0 24575 2 x 0,34 22 4,1 6,8 32,0
24568 3 x 0,25 24 4,1 7,5 33,0 24576 3 x 0,34 22 4,3 10,2 40,0
24569 4 x 0,25 24 4,4 10,0 40,0 24577 4 x 0,34 22 4,6 13,6 55,0
24570 5 x 0,25 24 4,7 12,5 48,0 24578 5 x 0,34 22 5,0 17,0 60,0
24571 7 x 0,25 24 6,9 17,5 60,0 24579 7 x 0,34 22 7,3 23,8 80,0
24572 12 x 0,25 24 7,4 30,1 91,0 24580 12 x 0,34 22 7,9 40,8 127,0
24573 18 x 0,25 24 8,9 45,0 125,0 24581 18 x 0,34 22 9,7 61,2 175,0
24574 25 x 0,25 24 10,2 62,5 170,0 24582 25 x 0,34 22 10,0 85,0 238,0

Dimensions and specifications may be changed without prior notice. (RN05)

448
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

SUPERTRONIC-330 C-PUR cable for drag chains,


halogen-free, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special PUR sheathed cable, screened Bare copper conductor, extra fine wire to The materials used in manufacture are
Temperature range DIN VDE 0295 cl.6, col. 4, BS 6360 cl.6 cadmium-free and contain no silicone
flexing -30C to +80C Core insulation of PP and free from substances harmful to
fixed installation -40C to +80C Core identification to DIN 47100 the wetting properties of lacquers
Nominal voltage 300 V coloured Tests
Test voltage Cores stranded in layers with PUR outer sheath, flame retardant acc. to
core/core 1500 V optimal lay-length DIN VDE 0482-332-1-2,
core/screen 1000 V Wrapping over the outer layer DIN EN 60332-1-2/ IEC 60332-1 (equivalent
Insulation resistance Braided screen of tinned Cu wires, DIN VDE 0472 part 804 test method B)
min. 100 MOhm x km coverage approx. 85% Low-adhesion
Capacitance Core wrapping with fleece High flexibility at low temperatures
core/core 60 nF/km Outer sheath of special full polyurethane High abrasion resistance
Minimum bending radius compound type TMPU to Tear and cut-resistant
flexing 7,5x cable DIN VDE 0207-363-10-2/ DIN EN Notch resistant
fixed 4x cable 50363-10-2 Resistant to
Radiation resistance and acc. to UL-Std.1581 tab.50227 UV-radiation, Oxygen, Ozone, Hydrolysis,
up to 100x106 cJ/kg (up to 100 Mrad) Sheath colour grey (RAL 7001) Oil
Coupling resistance with meter marking Partially resistant to
max. 250 Ohm/km Microbial attack, Hydraulic fluid, Coolant
emulsion, Alkalis

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Especially suited for drag chain installation in dry, moist and wet environments and outdoors with flexible movement and without tensile stress or
forced movements. A highly-flexible PVC control cable suitable for frequent and fast lifting and bending stresses in machines and tool building, robot
systems and on constantly moving machine components. Long service lives guarantee reliable function and good cost efficiency. The dense screening
N
assures interference-free transmission of all signals and impulses. An ideal interference-free control cable for the above applications. For applications
which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
49797 2 x 0,14 26 4,4 11,2 32,0 49815 14 x 0,25 24 8,0 64,2 135,0
49798 3 x 0,14 26 4,5 14,1 35,0 49816 18 x 0,25 24 8,8 78,4 150,0
49799 4 x 0,14 26 4,8 15,5 40,0 49817 24 x 0,25 24 10,2 89,9 194,0
49800 5 x 0,14 26 5,0 18,3 45,0 49818 25 x 0,25 24 10,7 101,0 204,0
49801 7 x 0,14 26 5,8 27,8 66,0 49819 2 x 0,34 22 5,1 18,1 45,0
49802 10 x 0,14 26 6,7 39,3 86,0 49820 3 x 0,34 22 5,3 28,7 60,0
49803 12 x 0,14 26 6,8 42,1 94,0 49821 4 x 0,34 22 5,7 35,7 76,0
49804 14 x 0,14 26 7,1 45,3 102,0 49822 5 x 0,34 22 6,1 39,1 82,0
49805 18 x 0,14 26 7,8 54,1 118,0 49823 7 x 0,34 22 7,1 52,7 110,0
49806 24 x 0,14 26 8,8 66,3 149,0 49824 10 x 0,34 22 8,1 67,4 148,0
49807 25 x 0,14 26 9,2 68,4 156,0 49825 12 x 0,34 22 8,3 76,4 166,0
49808 2 x 0,25 24 4,8 14,9 38,0 49826 14 x 0,34 22 8,7 85,5 185,0
49809 3 x 0,25 24 5,0 18,8 44,0 49827 18 x 0,34 22 9,8 99,7 216,0
49810 4 x 0,25 24 5,3 21,3 51,0 49828 24 x 0,34 22 11,3 147,1 291,0
49811 5 x 0,25 24 5,7 31,0 68,0 49829 25 x 0,34 22 11,8 155,0 305,0
49812 7 x 0,25 24 6,6 39,6 82,0
49813 10 x 0,25 24 7,5 53,9 110,0
49814 12 x 0,25 24 7,7 59,1 124,0

Dimensions and specifications may be changed without prior notice. (RN05)

449
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

MULTISPEED-TRONIC-C-PUR safety against high


bending in drag chain systems, high flexible, halogen-free, screened, EMC-preferred
type, meter marking

Technical data Cable structure Properties


Special drag chain cables for high Bare copper, fine wire conductors, Unilay The materials used in manufacture are
mechanical stress in adapted to with short pitch length cadmium-free and contain no silicone
DIN VDE 0285-525-2-51/ Core insulation of special PP and free from substances harmful to
DIN EN 50525-2-51, Core identification to DIN 47100 the wetting properties of lacquers
DIN VDE 0285-525-2-21/ <7 cores: cores stranded in a layer Tests
DIN EN 50525-2-21 with optimal lay-length around a filler as per PUR outer sheath, flame retardant acc. to
and acc. to UL-Std.758 construction DIN VDE 0482-332-1-2,
AWM Style 20233 7 cores: cores stranded with optimal DIN EN 60332-1-2/ IEC 60332-1 (equivalent
Temperature range lay-length to bunch-construction with low DIN VDE 0472 part 804 test method B)
flexing -30C to +80C torsion strength, optimal selected short UL VW-1, CSA FT1
fixed installation -40C to +80C lay-length around a filler Low-Adhesion
Nominal voltage Special-TPE extruded as filler Halogen-free
U0/U 300/300 V with pressure, grey (RAL 7001) High property of alternating bending
Test voltage 3000 V Screen of Cu braid bare, coverage 85% strength
Insulation resistance max., with optimal pitch High tensile strength, abrasion- and impact
min. 100 MOhm x km Outer sheath of special-PUR resistance at low temperature
Minimum bending radius Sheath colour black (RAL 9005) Use in multi-shift operations under
flexing 7,5x cable with meter marking extremely high continuous bending loads
fixed installation 4x cable Abrasion resistance
Coupling resistance Tear resistance
max. 250 Ohm/km High stability
Radiation resistance Oil resistance
up to 100x106 cJ/kg (up to 100 Mrad) Better chemical resistance
UV and ozone resistance
Higher economical solution
Reduced , results low weight of moving
materials

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
non screened analogue type:
MULTISPEED-TRONIC-PUR,
confer page 448

Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and wet rooms
and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are installed
there, where the problems appear for the application in permanent stresses. These cables are installed everywhere, where high requirements for the
flexibility, abrasion, oxygen and chemical resistance are necessary. These screened cables are particularly suitable for the interference-free transmission
in instrumentation and control engineering applications. For applications which go beyond standard solutions we recommend for our especially
developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection
table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24614 2 x 0,25 24 5,4 74,0 39,0 24622 2 x 0,34 22 5,6 18,0 45,0
24615 3 x 0,25 24 5,6 19,0 45,0 24623 3 x 0,34 22 5,8 22,0 60,0
24616 4 x 0,25 24 5,9 22,0 51,0 24624 4 x 0,34 22 6,1 28,0 76,0
24617 5 x 0,25 24 6,2 26,0 68,0 24625 5 x 0,34 22 6,8 31,0 82,0
24618 7 x 0,25 24 8,7 35,0 83,0 24626 7 x 0,34 22 9,3 51,0 110,0
24619 12 x 0,25 24 9,4 58,0 122,0 24627 12 x 0,34 22 9,9 70,0 166,0
24620 18 x 0,25 24 11,5 79,0 160,0 24628 18 x 0,34 22 12,3 103,0 216,0
24621 25 x 0,25 24 13,0 99,0 210,0 24629 25 x 0,34 22 13,6 130,0 312,0

Dimensions and specifications may be changed without prior notice. (RN05)

450
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA

SUPER-PAAR-TRONIC 340-C-PUR cable for drag


chains, halogen-free, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special drag chain cable, stranded in pairs Bare copper conductor, extra fine wire to The materials used in manufacture are
Temperature range DIN VDE 0295 cl.6, col. 4, BS 6360 cl.6 cadmium-free and contain no silicone
flexing -30C to +80C and IEC 60228 cl.6 and free from substances harmful to
fixed installation -40C to +80C Core insulation of PP the wetting properties of lacquers
Nominal voltage 300 V Core identification to DIN 47100 Tests
Test voltage Cores stranded in pairs, pairs stranded PUR outer sheath, flame retardant acc. to
core/core 1500 V torsion-free in layers with optimal DIN VDE 0482-332-1-2,
core/screen 1000 V lay-length DIN EN 60332-1-2/ IEC 60332-1 (equivalent
Insulation resistance Wrapping over the outer layer DIN VDE 0472 part 804 test method B)
min. 100 MOhm x km Braided screen of tinned Cu wires, Oil resistance acc. to
Mutual capacitance coverage approx. 85% DIN VDE 0473-811-404/
core/core approx. 60 nF/km Core wrapping with fleece DIN EN 60811-404
Minimum bending radius Outer sheath of full polyurethane Halogen free
for permanent bending at 0,25 mm compound type TMPU to Weather, ozone and UV-resistant
flexing 7,5x cable DIN VDE 0207-363-10-2 / Chemical resistance to solvents, acids,
fixed 4x cable DIN EN 50363-10-2 and acc. to alkalis and hydraulic fluids
at 0,5-1,0 mm UL-Std.1581 tab.50.227 Advantages
flexing 10x cable Sheath colour grey (RAL 7001) Very high resistance to mechanical stresses
fixed 5x cable with meter marking Very good alternating bending strength
Coupling resistance High tear, abrasion and impact resistance,
max. 250 Ohm/km even at low temperatures
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad) Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Stranded in pairs, these fully-screened special drag chain cables can also be used where external, high-frequency interference influences pulse transfer.
They are used for permanently flexible stresses in machine and tool building, in robot technology, on constantly moving machine components and
for extended use in multi-shift operations. Developed to state-of-the-art technology, these highly-flexible data cable, with a cut resistant and
N
low-adhesion PUR outer sheath guaranteeing optimal service life and extremely good cost efficiency. This two-approvals single-core cable is preferred
for use in export-oriented mechanical engineering, in machine tools, production lines and systems engineering. Guaranteed extended use in multi-shift
operations with extremely high bending stresses. For applications which go beyond standard solutions we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for
drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x AWG-No. Outer Cop. Weight Part no. No.pairs x AWG-No. Outer Cop. Weight
no.cores x app. mm weight app. no.cores x app. mm weight app.
cross-sec. kg / km kg / km cross-sec. kg / km kg / km
mm mm
49830 1 x 2 x 0,25 24 4,8 14,0 26,0 49853 6 x 2 x 0,5 20 11,8 103,0 181,0
49831 2 x 2 x 0,25 24 6,7 32,0 61,0 49854 8 x 2 x 0,5 20 14,2 148,4 274,0
49832 3 x 2 x 0,25 24 7,1 38,4 70,0 49855 10 x 2 x 0,5 20 16,5 180,0 332,0
49833 4 x 2 x 0,25 24 7,6 43,2 82,0 49856 14 x 2 x 0,5 20 16,9 218,3 390,0
49834 5 x 2 x 0,25 24 8,3 51,5 99,0 49857 1 x 2 x 0,75 19 6,2 35,2 56,0
49835 6 x 2 x 0,25 24 9,0 71,8 126,0 49858 2 x 2 x 0,75 19 9,2 61,4 102,0
49836 8 x 2 x 0,25 24 10,5 74,4 147,0 49859 3 x 2 x 0,75 19 9,8 87,1 144,0
49837 10 x 2 x 0,25 24 11,9 90,0 179,0 49860 4 x 2 x 0,75 19 11,2 95,2 160,0
49838 14 x 2 x 0,25 24 12,7 111,2 210,0 49861 5 x 2 x 0,75 19 12,2 115,0 193,0
49839 1 x 2 x 0,34 22 5,1 20,0 35,0 49862 6 x 2 x 0,75 19 13,2 137,1 216,0
49840 2 x 2 x 0,34 22 7,2 41,0 80,0 49863 8 x 2 x 0,75 19 15,6 184,4 327,0
49841 3 x 2 x 0,34 22 7,6 52,2 100,0 49864 10 x 2 x 0,75 19 18,4 259,8 451,0
49842 4 x 2 x 0,34 22 8,3 59,1 118,0 49865 14 x 2 x 0,75 19 18,9 318,4 521,0
49843 5 x 2 x 0,34 22 9,0 67,0 134,0 49866 1x2x1 18 6,7 42,0 64,0
49844 6 x 2 x 0,34 22 9,9 86,4 162,0 49867 2x2x1 18 10,0 73,0 120,0
49845 8 x 2 x 0,34 22 11,9 107,5 214,0 49868 3x2x1 18 10,8 93,6 160,0
49846 10 x 2 x 0,34 22 13,9 131,0 270,0 49869 4x2x1 18 11,7 117,8 184,0
49847 14 x 2 x 0,34 22 14,1 150,0 304,0 49870 5x2x1 18 13,2 139,0 217,0
49848 1 x 2 x 0,5 20 5,8 22,5 47,0
49849 2 x 2 x 0,5 20 8,4 53,0 100,0
49850 3 x 2 x 0,5 20 9,0 72,8 131,0
49851 4 x 2 x 0,5 20 10,0 75,6 149,0
49852 5 x 2 x 0,5 20 11,0 85,7 169,0

Dimensions and specifications may be changed without prior notice. (RN05)

451
UL/CSA MOTOR, SERVO & FEEDBACK CABLES

452
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX-EMV-UV-2YSLCYK-J UL/CSAMotorsupply
cable 1000 V, for power supply connections to frequency converters, double screened,
meter marking.

Technical data Cable structure Properties


Special motor power supply cable for Bare copper-conductor, to Low mutual capacitance
frequency converters to Style 2570 DIN VDE 0295 cl.5, fine-wire, Meets EMC requirements acc. to
Temperature range BS 6360 cl.5, IEC 60228 cl.5 EN 55011 and DIN VDE 0875 part 11
flexing -5C bis +80C Core insulation of polyethylene (PE) Low coupling resistance for high
fixed installation -40C bis +80C Core indentification BN, BK, GY electromagnetic compatibility
Nominal voltage GN-YE conductor UV-resistant
UL 1000 V Cores stranded in concentric layers Outdoor application
Test voltage 4000 V 1. Screen with special aluminium film This screened motor supply cable with low
Insulation resistance 2. Tinned copper braided screen, mutual capacitance of the single cores
min. 200 MOhm x km approx. 85% coverage because of the special PE core insulation
Coupling resistance Outer sheath of special PVC and low screen capacitance enable a
acc. to different cross-section Sheath colour black (RAL 9005) low-loss transmission of the power
max. 250 Ohm/km with meter marking compared to PVC-sheathed connecting
Minimum bending radius cables
fixed installation for outer : Due to the optimal screening an
up to 12 mm: 5x cable interference-free operation of frequency
> 12-20 mm: 7,5x cable converters is obtained
> 20 mm: 10x cable The materials used in manufacture are
free-movement for outer : cadmium-free and contain no silicone
up to 12 mm: 10x cable and free from substances harmful to
> 12-20 mm: 15x cable the wetting properties of lacquers
> 20 mm: 20x cable Tests
Radiation resistance PVC self-extinguishing and flame retardant
up to 80x106 cJ/kg (up to 80 Mrad) acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)

Note
**) The current carrying capacity for
N
permanent operation at ambient temperature
of 30C. For deviating ambient temperatures
the conversion factors should be used and
for further see the indication in
DIN VDE 0298 part 4.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This TOPFLEX-EMV-UV-2YSLCYK-J UL/CSA motor connection cable for the frequency converters secures the EMC in systems and buildings, equipment
with devices and machineries, which can emit electromagnetic interference fields that can impact the environment in an illegal manner. It is used as
a connection and connecting cable under average mechanical stress for fixed installations and sometimes for free movement in dry, moist and wet
rooms and outside. It is used in the automotive industry, food processing industry, transfer streets, packaging industry, machine tools, handling
equipment, in the industry it is used for pumps, fans, transport belts, etc. Used in explosion proof areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. app. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight app. kg / km
mm app.nF / km app.nF / km Ohm/km Ohm/km in Amperes kg / km
22320 4 G 1,5 10,4 0 95,0 140,0 16
22321 4 G 2,5 12,5 80 130 18 210 26 150,0 300,0 14
22322 4G4 14,2 90 150 11 210 34 235,0 485,0 12
22323 4G6 15,2 90 150 6 150 44 320,0 630,0 10
22324 4 G 10 19,5 120 200 7 180 61 533,0 860,0 8
22325 4 G 16 22,9 140 230 9 190 82 789,0 1290,0 6
22326 4 G 25 27,1 120 210 4 95 108 1236,0 1860,0 4
22327 4 G 35 29,6 150 260 3 85 135 1662,0 2610,0 2

Continuation

453
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX-EMV-UV-2YSLCYK-J UL/CSAMotorsupply
cable 1000 V, for power supply connections to frequency converters, double screened,
meter marking.
Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. app. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight app. kg / km
mm app.nF / km app.nF / km Ohm/km Ohm/km in Amperes kg / km
22328 4 G 50 35,2 190 320 2 40 168 2345,0 2950,0 1
22329 4 G 70 41,4 190 320 2 45 207 3196,0 3950,0 2/0
22330 4 G 95 46,0 250 410 1 50 250 4316,0 5300,0 3/0
22331 4 G 120 50,8 292 5435,0 6600,0 4/0
22332 4 G 150 58,3 335 6394,0 7040,0 300 kcmil
22333 4 G 185 65,5 382 7639,0 8380,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RN07)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

454
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA


Motor supply cable 1000 V, for power supply connections to frequency converters, double
screened, meter marking.

Technical data Cable structure Properties


Special motor power supply cable for Bare copper, fine wire conductor to Low mutual capacitance
frequency converters to Style 2570 DIN VDE 0295 cl.5, BS 6360 cl.5 and Meets EMC requirements acc. to
Temperature range IEC 60228 cl.5 EN 55011 and DIN VDE 0875 part 11
flexing -5C bis +80C Core insulation of polyethylene (PE) Low coupling resistance for high
fixed installation -40C bis +80C Core identification BK, BN, GY electromagnetic compatibility
Nominal voltage GN-YE conductor (divided into 3) Due to the optimal screening an
UL 1000 V Cores stranded in concentric layers interference-free operation of frequency
Test voltage 4000 V 3+3 core design converters is obtained
Insulation resistance 1. Screen with special aluminium film The 3 Plus-construction of motor power
min. 200 MOhm x km 2. Tinned copper braided screen, supply cables features a symmetrical
Coupling resistance approx. 85% coverage 3-core design, improved in terms of EMC
acc. to different cross-section Outer sheath of special PVC characteristics comparing favorably with a
max. 250 Ohm/km Sheath colour black (RAL 9005) 4-core version. The protective conductor PE,
Minimum bending radius with meter marking divided into 3 is uniformly stranded in the
fixed installation for outer : interstices. This enables an extremely
up to 12 mm: 5x cable concentric structure
> 12-20 mm: 7,5x cable The minimum cross-section of 0,752 meets
> 20 mm: 10x cable the requirements of DIN EN 60204 part 1
free-movement for outer : uv-resistant
up to 12 mm: 10x cable Outdoor application
> 12-20 mm: 15x cable This screened motor supply cable with low
> 20 mm: 20x cable mutual capacitance of the single cores
Radiation resistance because of the special PE core insulation
up to 80x106 cJ/kg (up to 80 Mrad) and low screen capacitance enable a
low-loss transmission of the power
compared to PVC-sheathed connecting
cables
The materials used in manufacture are
cadmium-free and contain no silicone
N
and free from substances harmful to
the wetting properties of lacquers
Tests
PVC self-extinguishing and flame retardant
acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)

Note
**) The current carrying capacity for
permanent operation at ambient temperature
of 30C. For deviating ambient temperatures
the conversion factors should be used and
for further see the indication in
DIN VDE 0298 part 4.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
It is used as a connection and connecting cable under average mechanical stress for fixed installation and sometimes for free movement in dry, moist
and wet rooms and outside. It is used in the automotive industry, food processing industry, transfer streets, packaging industry, machine tools, handling
equipment, in the industry it is used for pumps, fans, transport belts and in air condition systems, etc. Used in explosion proof areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation

455
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX-EMV-UV-3 PLUS 2YSLCYK-J UL/CSA


Motor supply cable 1000 V, for power supply connections to frequency converters, double
screened, meter marking.
Part no. No.cores x Outer Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. app. mm at 1 MHz at 30 MHz with 3 loaded cores weight app. kg / km
mm Ohm/km Ohm/km in Amperes kg / km
22193 3 x 1,5 + 3 G 0,25 10,0 18 86,0 140,0 16
22194 3 x 2,5 + 3 G 0,5 11,4 18 210 26 144,0 220,0 14
22195 3 x 4 + 3 G 0,75 13,0 11 210 34 224,0 323,0 12
22196 3 x 6 + 3 G 1,0 15,0 6 150 44 298,0 420,0 10
22197 3 x 10 + 3 G 1,5 18,4 7 180 61 491,0 615,0 8
22198 3 x 16 + 3 G 2,5 21,0 9 190 82 723,0 819,0 6
22199 3 x 25 + 3 G 4,0 25,3 4 95 108 1138,0 1325,0 4
22223 3 x 35 + 3 G 6,0 27,8 3 85 135 1535,0 1718,0 2
22224 3 x 50 + 3 G 10,0 32,6 2 40 168 2208,0 2399,0 1
22225 3 x 70 + 3 G 10,0 38,1 2 45 207 2871,0 3056,0 2/0
22226 3 x 95 + 3 G 16,0 41,0 1 50 250 3953,0 4162,0 3/0
22227 3 x 120 + 3 G 16,0 46,4 292 4836,0 5075,0 4/0
22228 3 x 150 + 3 G 25,0 53,5 335 5412,0 6128,0 300 kcmil
22229 3 x 185 + 3 G 35,0 59,5 382 6969,0 7189,0 350 kcmil
22230 3 x 240 + 3 G 42,5 65,1 8540,0 9540,0 500 kcmil

Dimensions and specifications may be changed without prior notice. (RN07)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

456
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX-MOTOR-EMV 103 low capacitance power


supply cable 1000 V, increased ampacity, meter marking

Technical data Cable structure Properties


Special motor power supply cable Bare copper, fine wire conductor to Tests
for frequency converters acc. to DIN VDE 0295 cl.5, BS 6360 cl.5 or PVC self-extinguishing and flame retardant
UL-AWM style 21179 IEC 60228 cl.5 acc. to DIN VDE 0482-332-1-2,
Temperature range Core insulation of special-polymer DIN EN 60332-1-2, IEC 60332-1 (equivalent
flexing -5C to +70C Core identification to DIN VDE 0293-308 DIN VDE 0472 part 804 test method B)
fixed installation -40C to +80C - up to 5 cores coloured Features Special-Polymer-insulation secures
Permissible operating temperature - from 7 cores, black with continuous a lower dielectric loss, double potential
at conductor +90C white numbering strength, high longevity and low
Nominal voltage GN-YE conductor screen-interference currents to include
VDE U0/U 600/1000 V Cores stranded in concentric layers increased current carrying capacity
UL 1000 V 1. Screen with special aluminium film Meets EMC requirements according to
Test voltage 2500 V 2. Tinned copper braided screen, EN 55011 and DIN VDE 0875 part 11
Insulation resistance coverage approx. 80% Low coupling resistance for high
min. 200 MOhm x km Outer sheath of special PVC electromagnetic compatibility
Coupling resistance Sheath colour orange (RAL 2003) This screened motor supply cable with low
acc. to different cross-sections with meter marking mutual capacitance of the single cores
max. 250 Ohm/km because of the special Polymer core
Mutual capacitance insulation and low screen capacitance
acc. to different cross-sections enable a low-loss transmission of the power
core/core 70 to 250 nF/km compared to PVC-sheathed connecting
core/screen 110 to 410 nF/km cables
Minimum bending radius Due to the optimal screening an
fixed installation for outer : interference-free operation of frequency
up to 12 mm: 5x cable converters is obtained
> 12-20 mm: 7,5x cable Design acc. to the requirements of
> 20 mm: 10x cable VdS 3501:2006-04
free-movement for outer : The materials used in manufacture are
up to 12 mm: 10x cable cadmium-free and contain no silicone
> 12-20 mm: 15x cable
> 20 mm: 20x cable
and free from substances harmful to
the wetting properties of lacquers N
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This UL/CSA motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings, facilities with units
and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a supply and connecting
cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments. Used in the automotive and
food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable
for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
22689 3 G 1,5 9,4 72,0 200,0 16 22698 5G4 15,4 321,0 567,0 12
22690 4 G 1,5 10,4 95,0 230,0 16 22699 7G4 18,2 352,0 603,0 12
22691 5 G 1,5 11,2 117,0 258,0 16 22700 4G6 15,2 320,0 633,0 10
22692 7 G 1,5 13,2 148,0 281,0 16 22701 5G6 16,8 439,0 679,0 10
22693 3 G 2,5 11,2 137,0 270,0 14 22702 7G6 20,0 501,0 771,0 10
22694 4 G 2,5 12,5 150,0 300,0 14 22703 4 G 10 19,5 533,0 860,0 8
22695 5 G 2,5 13,5 200,0 352,0 14 22704 5 G 10 21,6 711,0 1029,0 8
22696 7 G 2,5 16,0 230,0 473,0 14 22705 4 G 16 23,1 789,0 1290,0 6
22697 4G4 14,2 235,0 485,0 12 22706 4 G 25 27,1 1236,0 1862,0 4

Dimensions and specifications may be changed without prior notice. (RN07)

457
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX 600 VFD EMC-preferred type, flexible motor power


supply cable, oil-resistant, NFPA 79 Edition 2012

Technical data Cable structure Properties


PVC motor supply cable acc. to Tinned copper conductor, fine wire self-extinguishing and flame retardant
UL-Std.1277 and UL-Std.2277 with AWG dimensions acc. to CSA FT4
Temperature range Core insualtion of special PVC The materials used in manufacture are
-25C to +90C with transparent nylon skin cadmium-free and contain no silicone
Nominal voltage Black cores with continuous white numbering and free from substances harmful to
TC 600 V GN-YE conductor in the outer layer the wetting properties of lacquers
WTTC 1000 V Cores stranded in layers with optimal UV-resistant
Test voltage 4000 V lay-length Tests
Minimum bending radius Fleece UL:
flexing 6x cable 1. Screening with special aluminium foil TC-ER, WTTC 1000 V, MTW, NFPA 79 2012,
Coupling resistance 2. Screening with braid of tinned copper PLTC-ER (AWG 18 - AWG 12),
max. 250 Ohm/km wires, optimal coverage approx. 85% ITC-ER (AWG 18 - AWG 12) OIL RES I & II,
Separator 90C dry / 75C wet, Cold Bend Test -40C
Outer sheath of special PVC Class 1 Div. 2 per NEC Art. 336, 392, 501
Sheath colour black (RAL 9005) or CSA:
orange (RAL 2003) c (UL) CIC-TC FT4
with length marking in feet AWM I/II A/B FT4

Note
VFD = Variable Frequency Drive

Application
Flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage) and
tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures. Approved to
NFPA 79 edition 2012 for open, unprotected installation on cable trays and from cable trays to the machine. The special PVC sheath is extremly
resistant to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes and in the
earth.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Sheath colour black Sheath colour orange
Part no. No.cores Cross- Outer Cop. Weight Part no. No.cores Cross- Outer Cop. Weight
x AWG-No. section mm app. mm weight app. x AWG-No. section mm app. mm weight app.
kg / km kg / km kg / km kg / km
63139 4 x 18 0,963 9,9 52,0 164,0 63147 4 x 18 0,963 9,9 52,0 164,0
63140 4 x 16 1,31 11,4 72,0 183,0 63148 4 x 16 1,31 11,4 72,0 183,0
63137 4 x 14 2,08 12,5 118,0 197,0 63149 4 x 14 2,08 12,5 118,0 197,0
63141 4 x 12 3,31 14,0 182,0 267,0 63150 4 x 12 3,31 14,0 182,0 267,0
63142 4 x 10 5,26 17,1 256,0 402,0 63151 4 x 10 5,26 17,1 182,0 267,0
63143 4x8 8,37 22,3 417,0 668,0 63152 4x8 8,37 22,3 417,0 668,0
63144 4x6 13,31 25,4 651,0 918,0 63153 4x6 13,31 25,4 651,0 918,0
63145 4x4 21,21 30,1 910,0 1363,0 63154 4x4 21,21 30,1 910,0 1363,0
63146 4x2 33,6 35,3 1411,0 1994,0 63155 4x2 33,6 35,3 1411,0 1994,0

Dimensions and specifications may be changed without prior notice. (RN07)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

458
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX 650 VFD EMC-preferred type, flexible motor power


supply cable with control cores, oil-resistant, NFPA 79 Edition 2012

Technical data Cable structure Properties


TPE motor supply cable acc. to Tinned copper conductor, fine wire self-extinguishing and flame retardant
UL-Std.1277 and UL-Std.2277 with AWG measures acc. to CSA FT4
Temperature range Core insualtion of special PVC The materials used in manufacture are
flexing -25C to +105C with transparent nylon skin cadmium-free and contain no silicone
Nominal voltage Black supply cores with continuous white and free from substances harmful to
TC 600 V numbering the wetting properties of lacquers
WTTC 1000 V 2 black control cores withnumber 5+6 UV-resistant
Test voltage GN-YE conductor in the outer layer Tests
power supply cores 4000 V Control cores screened in pairs with UL:
control cores 2000 V plastic-coated aluminium foil, tinned drain TC-ER, WTTC 1000 V, MTW, NFPA 79 2012,
Minimum bending radius wire PLTC-ER (AWG 18 - AWG 12),
flexing 6x cable Control cores stranded in pairs and laid up ITC-ER (AWG 18 - AWG 12) OIL RES I & II,
Coupling resistance in layers with optimal lay-length with the 90C dry / 75C wet, Cold Bend Test -40C
max. 250 Ohm/km power supply cores Class 1 Div. 2 per NEC Art. 336, 392, 501
1. Screening with plastic-coated CSA:
aluminium foil c (UL) CIC-TC FT4
2. Screening from tinned Cu-braid, AWM I/II A/B FT4
optimal coverage approx. 85%
Separator Note
Outer sheath of special TPE VFD = Variable Frequency Drive
Sheath colour black (RAL 9005) or orange
(RAL 2003)
with length marking in feet

Application
Flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage) and
tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures. Approved to
NFPA 79 edition 2012 for open, unprotected installation on cable trays and from cable trays to the machine. The special TPE sheath is extremly resistant
to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes and in the earth.
EMC = Electromagnetic compatibillity
N
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Sheath colour black
Part no. No. cores Cross- Outer Cop. Weight
x AWG-No. section mm app. mm weight app. kg / km
kg / km
63156 4x AWG 16 +2x AWG 18 1,31/ 0,963 13,0 88,0 259,0
63157 4x AWG 14 +2x AWG 18 2,08/ 0,963 14,0 133,0 370,0
63138 4x AWG 14 +2x AWG 14 2,08/ 2,08 14,0 159,0 399,0
63158 4x AWG 12 +2x AWG 18 3,31/ 0,963 15,3 197,0 435,0
63159 4x AWG 12 +2x AWG 14 3,31/ 2,08 15,7 224,0 466,0
63160 4x AWG 10 +2x AWG 14 5,26/ 2,08 18,2 301,0 703,0
63161 4x AWG 8 +2x AWG 14 8,37/ 2,08 24,1 457,0 901,0
63162 4x AWG 6 +2x AWG 14 13,31/ 2,08 27,4 615,0 1275,0
63163 4x AWG 4 +2x AWG 14 21,21/ 2,08 33,4 1450,0 1861,0

Sheath colour orange


Part no. No. cores Cross- Outer Cop. Weight
x AWG-No. section mm app. mm weight app. kg / km
kg / km
62876 4x AWG 16 +2x AWG 18 1,31/ 0,963 13,0 88,0 259,0
62877 4x AWG 14 +2x AWG 18 2,08/ 0,963 14,0 133,0 370,0
62878 4x AWG 14 +2x AWG 14 2,08/ 2,08 14,0 159,0 399,0
62879 4x AWG 12 +2x AWG 18 3,31/ 0,963 15,3 197,0 435,0
62880 4x AWG 12 +2x AWG 14 3,31/ 2,08 15,7 224,0 466,0
62881 4x AWG 10 +2x AWG 14 5,26/ 2,08 18,2 301,0 703,0
62882 4x AWG 8 +2x AWG 14 8,37/ 2,08 24,1 457,0 901,0
62883 4x AWG 6 +2x AWG 14 13,31/ 2,08 27,4 615,0 1275,0
62884 4x AWG 4 +2x AWG 14 21,21/ 2,08 33,4 1450,0 1861,0

Dimensions and specifications may be changed without prior notice. (RN07)

459
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX 1000 VFD EMC-preferred type, flexible motor power supply


cable with control cores, oil-resistant, NFPA79 Edition 2012

Technical data Cable structure Properties


Motor power supply cable for VFDs Bare copper-conductor, fine-wire with Resistant to oil and sunlight
acc. to UL-Std. 83, 1277 and 2277 AWG dimensions Due the optimal screening an
Temperature range Core insualtion of special PVC interference-free operation of
flexing -25C to +90C with clear nylon coating frequency container is obtained
Nominal voltage Core identification black cores with The materials used in manufacture are
UL 1277 - TC 600 V continuous white numbering cadmium-free and contain no silicone
UL 2277 - WTTC 1000 V GN-YE conductor (divided into 3) and free from substances harmful to
Test voltage 2500 V Cores stranded in concentric layers the wetting properties of lacquers
Minimum bending radius 3 power + 3 ground conductor design Tests
flexing 15x cable 1. Screen with special aluminium film Behavior in fire acc. to CIC FT4
fixed installation 7,5x cable 2. Tinned copper braided screen, UL
Coupling resistance coverage approx. 80% UL Type TC-ER, UL 83, 1277, 2277,
max. 250 Ohm/km Outer sheath of special TPE WTTC, Oil Res I, NFPA 2012
Sheath colour black (RAL 9005) CSA
with length marking in feet c(UL) Type CIC FT4, CSA C22.2 No. 230,
CSA C22.2 No. 239

Note
VFD = Variable Frequency Drive

Application
It is used as a power supply cable under average mechanical stress for fixed installation and sometimes for free movement in dry, moist wet rooms
and outside. It is used in the automotive industry, food processing industry, transfer streets, packaging industry, machine tools, handling equipment,
other industrial uses include pumps, fans, transport belts and in air conditioning systems, etc. Used in explosion proof areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No. power cores No. ground cores No. cores x Outer Cop. Weight
x AWG-No. x AWG-No. cross-section app. mm weight app. kg / km
mm kg / km
59398 3x AWG 8 + 3x AWG 16 (3x 8,37 + 3x 1,31) 17,1 372,0 573,0
59399 3x AWG 6 + 3x AWG 14 (3x 13,3 + 3x 2,08) 19,3 554,0 735,0
59400 3x AWG 4 + 3x AWG 12 (3x 21,2 + 3x 3,3) 24,5 831,0 1225,0
59401 3x AWG 2 + 3x AWG 10 (3x 33,6 + 3x 5,26) 27,8 1258,0 1737,0
59402 3x AWG 1 + 3x AWG 8 (3x 42,4 + 3x 8,37) 31,1 1615,0 2225,0
59403 3x AWG 1/0 + 3x AWG 8 (3x 53,4 + 3x 8,37) 33,1 1938,0 2604,0
59404 3x AWG 2/0 + 3x AWG 8 (3x 67,5 + 3x 8,37) 35,8 2344,0 3089,0
59405 3x AWG 3/0 + 3x AWG 6 (3x 85 + 3x 13,3) 38,6 2994,0 3823,0
59406 3x AWG 4/0 + 3x AWG 6 (3x 107,2 + 3x 13,3) 44,5 3590,0 4700,0
59407 3x AWG 250 kcmil + 3x AWG 6 (3x 127 + 3x 13,3) 48,4 4177,0 5487,0
59408 3x AWG 300 kcmil + 3x AWG 4 (3x 152 + 3x 21,2) 50,9 5104,0 6530,0
59409 3x AWG 350 kcmil + 3x AWG 2 (3x 178 + 3x 33,6) 54,0 6218,0 7768,0
59410 3x AWG 400 kcmil + 3x AWG 2 (3x 203 + 3x 33,6) 55,5 6875,0 8492,0
59411 3x AWG 500 kcmil + 3x AWG 2 (3x 254 + 3x 33,6) 60,5 8303,0 10130,0

Dimensions and specifications may be changed without prior notice. (RN07)

460
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX-EMV-UV 2YSLC11Y-J UL/CSA Motor


supply cable 1000 V, for power supply connections to frequency converters, double
screened, meter marking.

Technical data Cable structure Properties


Special PUR motor power supply cable for Bare copper, fine wire conductor to Meets EMC requirements acc. to
frequency converters to UL AWM style DIN VDE 0295 cl.5, BS 6360 cl.5 or EN 55011 and DIN VDE 0875 part 11
20234 and CSA AWM adapted to IEC 60228 cl.5 PUR outer sheath: low adhesion, flame
DIN VDE 0250 Core insulation of polyethylen (PE) retardant, extremely abradion resistant,
Temperature range Core indentification BK, BN, GY halogen-free, resistant to UV, oil, hydrolysis
flexing -5C to +80C GN-YE conductor and microbial attack
fixed installation -40C to +80C Cores stranded in concentric layers Low mutual capacitance
Nominal voltage 1. Screen with special aluminium film Low coupling resistance for high
UL 1000 V 2. Tinned copper braided screen, electromagnetic compatibility
Test voltage 4000 V approx. 85% coverage UV-resitant
Insulation resistance Outer sheath of PUR Outdoor application
min. 200 MOhm x km Sheath colour black (RAL 9005) This screened motor supply cable with low
Minimum bending radius with meter marking mutual capacitance of the single cores
fixed installation for outer : because of the special PE core insulation
up to 12 mm: 5x cable Note and low screen capacitance enable a
> 12-20 mm: 7,5x cable **) The current carrying capacity for low-loss transmission of the power
> 20 mm: 10x cable permanent operation at ambient temperature compared to PVC-sheathed connecting
free-movement for outer : of 30C. For deviating ambient temperatures cables
up to 12 mm: 10x cable the conversion factors should be used and Due to the optimal screening an
> 12-20 mm: 15x cable for further see the indication in interference-free operation of frequency
> 20 mm: 20x cable DIN VDE 0298 part 4. converters is obtained
Coupling resistance AWG sizes are approximate equivalent The materials used in manufacture are
acc. to different cross-section values. The actual cross-section is in mm. cadmium-free and contain no silicone
max. 250 Ohm/km and free from substances harmful to
Radiation-resistance the wetting properties of lacquers
up to 80x106 cJ/kg (up to 80 Mrad) Tests
PUR outer sheath self-extinguishing and
flame retardant to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2/IEC 60332-1 (equivalent
N
DIN VDE 0472 part 804 test method B)

Application
This TOPFLEX-EMV-UV-2YSLC11Y-J UL/CSA motor power supply cable with PUR outher sheath for the frequency converters assures electromagnetic
compatibillity in plants and buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause
adverse effects on the surroundings. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements
in dry, moist and wet environments and for outdoor applications. Used in the automotive and food industries, environmental technology, packaging
industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor
belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. app. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight app. kg / km
mm app.nF / km app.nF / km Ohm/km Ohm/km in Amperes kg / km
22389 4 G 1,5 10,3 18 95,0 230,0 16
22390 4 G 2,5 12,3 80 130 18 210 26 150,0 300,0 14
22391 4G4 13,9 90 150 11 210 34 235,0 485,0 12
22392 4G6 15,3 90 150 6 150 44 320,0 630,0 10
22393 4 G 10 19,5 120 200 7 180 61 533,0 860,0 8
22394 4 G 16 23,3 140 230 9 190 82 789,0 1290,0 6
22395 4 G 25 27,4 120 211 4 95 108 1180,0 1800,0 4
22396 4 G 35 30,3 150 260 3 85 135 1662,0 2610,0 2
22397 4 G 50 35,5 190 320 2 40 168 2345,0 2950,0 1
22398 4 G 70 40,2 190 320 2 45 207 3196,0 3950,0 2/0
22399 4 G 95 44,5 250 410 1 50 250 4316,0 5300,0 3/0
22566 4 G 120 50,3 292 5435,0 6600,0 4/0
22567 4 G 150 56,1 335 6394,0 7040,0 300 kcmil
22568 4 G 185 58,0 382 7639,0 8380,0 350 kcmil

Dimensions and specifications may be changed without prior notice. (RN07)

461
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX MOTOR EMV 1/1 triple-screened, low


capacitance, 80C, 1000 V, high flexible motor supply cable, meter marking

Technical data Cable structure Properties


Special PUR motor power supply cable Bare copper-conductor, to PUR outer sheath: low adhesion, flame
for frequency converter to DIN VDE 0295 cl.5, fine-wire, retardant, extremely abrasion resistant,
UL AWM Style 20234 and CSA AWM IEC 60228 cl.5 halogen-free, resistant to UV, oil, hydrolysis
adapted to DIN VDE 0250 Core insulation of special polyethylene (PE) and microbial attack
Temperature range Core identification BK, BN, GY This screened motor power supply cable,
flexing -30C to +80C GN-YE conductor with low mutual capacitance because of
fixed installation -40C to +80C Cores stranded in layers the special PE core insulation, enable
Permissible operating temperature 1. Screen of semi-conductive fleece low-loss transmission of power compared
at conductor +90C 2. Aluminium-coated polyester film to PVC-sheathed power supply cables
Nominal voltage 3. Tinned copper braided screen, The optimal triple screening enables
VDE U0/U 600/1000 V coverage approx. 85% interference-free operation of frequency
UL 1000 V Outer sheath of PUR converters
Test voltage 3000 V Sheath colour orange (RAL 2003) Optimum compliance with requirements
Mutual capacitance at 4 kHz acc. to DESINA for electromagnetic compatibility (EMC)
acc. to different cross-section with meter marking due to the triple screening
core/core 70-250 nF/km The materials used in manufacture are
core/screen 110-410 nF/km cadmium-free and contain no silicone
Insulation resistance and free from substances harmful to
min. 200 MOhm x km the wetting properties of lacquers
Minimum bending radius Tests
fixed installation, for outside : PUR outer sheath self-extinguishing and
up to 12 mm: 5x cable flame retardant to DIN VDE 0482-332-1-2,
> 12-20 mm: 7,5x cable DIN EN 60332-1-2, IEC 60332-1 (equivalent
> 20 mm: 10x cable DIN VDE 0472 part 804 test method B)
free-movement, for outside :
up to 12 mm: 10x cable Note
> 12-20 mm: 15x cable **) The current carrying capacity for
> 20 mm: 20x cable permanent operation at ambient temperature
Coupling resistance of 30C. For deviating ambient temperatures
acc. to different cross-section the conversion factors should be used and
max. 250 Ohm/km for further see the indication in
Radiation resistance DIN VDE 0298 part 4.
up to 80x106 cJ/kg (up to 80 Mrad) AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This TOPFLEX MOTOR EMV 1/1 two-approvals, triple-screened motor power supply cable for frequency converters provides outstanding EMC in
machines and systems. Suitable as a supply and connecting cable for high mechanical stresses, in fixed installations and occasional free movements
in dry, moist and wet environments, as well as outdoors. Areas of application include machine tools, processing and manufacturing machinery,
machining centres, industrial robots, transfer lines, handling equipment, etc.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. app. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight app. kg / km
mm app.nF / km app.nF / km Ohm/km Ohm/km in Amperes kg / km
78377 4 G 1,5 11,5 70 110 18 95,0 230,0 16
78378 4 G 2,5 13,5 80 130 18 210 26 150,0 300,0 14
78379 4G4 15,8 90 150 11 210 34 235,0 485,0 12
78380 4G6 17,8 90 150 6 150 44 320,0 630,0 10
708609 4 G 10 21,6 120 200 7 180 61 533,0 860,0 8
708610 4 G 16 25,4 120 210 9 190 82 789,0 1290,0 6
708611 4 G 25 31,0 140 230 4 95 108 1180,0 1800,0 4
708612 4 G 35 33,0 150 260 3 85 135 1662,0 2610,0 2
78384 4 G 50 39,0 190 320 2 40 168 2345,0 2950,0 1
78385 4 G 70 45,0 190 320 2 45 207 3196,0 3950,0 2/0
78386 4 G 95 50,1 250 410 1 50 250 4316,0 5300,0 3/0
78387 4 G 120 54,2 292 5435,0 6600,0 4/0
78388 4 G 150 61,3 335 6394,0 7040,0 300 kcmil
78479 4 G 185 64,2 382 7639,0 8380,0 350 kcmil

Dimensions and specifications may be changed without prior notice.

462
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX-MOTOR-EMV 3/3 triple-screened, low


capacitance, 80C, 1000 V, PUR flexible motor supply cable, meter marking

Technical data Cable structure Properties


Special PUR motor power supply Bare copper-conductor, to PUR outer sheath: low adhesion, flame
cable for frequency converter to DIN VDE 0295 cl.5, fine-wire, retardant, extremely abrasion resistant,
UL AWM Style 20234 and CSA AWM BS 6360 cl.5, IEC 60228 cl.5 halogen-free, resistant to UV, oil, hydrolysis
adapted to DIN VDE 0250 Core insulation of special polyethylene (PE) and microbial attack
Temperature range Core identification black cores with This screened motor power supply cable,
flexing -30C to +80C imprint U1, V1, W3 with low mutual capacitance because of
fixed installation -40C to +80C GN-YE conductor (divided into 3) the special PE core insulation, enables
Permissible operating temperature Cores stranded in layers low-loss transmission of power compared
at conductor +90C 1. Screen of semi-conductive fleece to PVC-sheathed power supply cables
Nominal voltage 2. Aluminium-coated polyester film The optimal triple screening enables
VDE U0/U 600/1000 V 3. Tinned copper braided screen, interference-free operation of frequency
UL 1000 V coverage approx. 80% converters
Test voltage 3000 V Outer sheath of PUR Optimum compliance with requirements
Mutual capacitance at 4 kHz Sheath colour orange (RAL 2003) for electromagnetic compatibility (EMC)
acc. to different cross-section acc. to DESINA due to the triple screening
core/core 70-250 nF/km with meter marking The materials used in manufacture are
core/screen 110-410 nF/km cadmium-free and contain no silicone
Insulation resistance and free from substances harmful to
min. 200 MOhm x km the wetting properties of lacquers
Minimum bending radius Special features
fixed installation for outside : Here the earth core cross-section is divided
up to 12 mm: 5x cable into thirds, which lie in the interstices
> 12-20 mm: 7,5x cable between the power supply cores. Due to this
> 20 mm: 10x cable symmetrical construction, the PE insulation
free-movement for outside : and the triple screening, very low capacitance
up to 12 mm: 10x cable and inductance are achieved. EMC
> 12-20 mm: 15x cable compatibility is considerably enhanced.
> 20 mm: 20x cable Tests
Coupling resistance
acc. to different cross-section
PUR outer sheath self-extinguishing and
flame retardant to DIN VDE 0482-332-1-2, N
max. 250 Ohm/km DIN EN 60332-1-2, IEC 60332-1 (equivalent
Radiation resistance DIN VDE 0472 part 804 test method B)
up to 80x106 cJ/kg (up to 80 Mrad)
Note
All cables are also available in JB with
coloured cores acc. to DIN VDE 0295
**) The current carrying capacity for
permanent operation at ambient temperature
of 30C. For deviating ambient temperatures
the conversion factors should be used and
for further see the indication in
DIN VDE 0298 part 4.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This TOPFLEX MOTOR EMV 3/3 two-approvals, triple-screened motor power supply cable for frequency converters provides outstanding EMC in
machines and systems. Suitable as a supply and connecting cable for high mechanical stresses, in fixed installations and occasional free movements
in dry, moist and wet environments, as well as outdoors. Areas of application include machine tools, processing and manufacturing machinery,
machining centres, industrial robots, transfer lines, handling equipment, etc. By dividing the earth core into thirds and dividing it evenly in the interstices
between the power supply cores, a symmetrical structure has been achieved. This results in improved EMC, capacitance and inductance compared to
the 4-core version.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation

463
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPFLEX-MOTOR-EMV 3/3 triple-screened, low


capacitance, 80C, 1000 V, PUR flexible motor supply cable, meter marking
Part no. No.cores x Outer Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. app. mm at 1 MHz at 30 MHz with 3 loaded cores weight app. kg / km
mm Ohm/km Ohm/km in Amperes kg / km
78614 3 x 1,5 + 3 G 0,25 10,4 18 86,0 150,0 16
78615 3 x 2,5 + 3 G 0,5 12,1 18 210 26 144,0 240,0 14
78616 3 x 4 + 3 G 0,75 13,9 11 210 34 224,0 345,0 12
78617 3 x 6 + 3 G 1,0 15,5 6 150 44 298,0 460,0 10
78618 3 x 10 + 3 G 1,5 19,5 7 180 61 491,0 840,0 8
78619 3 x 16 + 3 G 2,5 22,5 9 190 82 723,0 930,0 6
78620 3 x 25 + 3 G 4,0 28,6 4 95 108 1138,0 1425,0 4
78621 3 x 35 + 3 G 6,0 29,6 3 85 135 1535,0 1900,0 2
708613 3 x 50 + 3 G 10,0 35,7 2 40 168 2208,0 2812,0 1
708371 3 x 70 + 3 G 10,0 43,0 2 45 207 2871,0 3370,0 2/0
708372 3 x 95 + 3 G 16,0 47,0 1 50 250 3953,0 4320,0 3/0
708373 3 x 120 + 3 G 25,0 52,0 292 4836,0 6160,0 4/0
78626 3 x 150 + 3 G 25,0 58,0 335 5412,0 7200,0 300 kcmil

Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

464
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPSERV PVC Motor and servo cables for fixed or not constantly
movements 0,6/1 kV, according to Siemens 6FX5008, Lenze, Bosch Rexroth

Technical data Cable structure Properties


Special PVC Motorcable acc. to Bare copper-conductor, low capacitance until 6mm (included)
UL AWM Style 2570 CSA AWM acc. to DIN EN 60228 oilresistant PVC outer sheath
VDE-recognized class 5: fine-wire Optimum compliance with requirements
Temperature range class 6: extra fine-wire for electromagnetic compatibility (EMC)
flexing -0C to +60C Core insulation by approx. 85% coverage from the
fixed installation -20C to +80C to 6 mm of halogen-free PP braided screen
Nominal voltage from 10 mm of PVC These cables are produced to high quality
VDE U0/U 600/1000 V Core identification specifications and conform to the
UL/CSA 1000 V power supply cores DESINA-standard
A.c. test voltage, 50 Hz core 1: black with imprint U/L1/C/L+ The materials used in manufacture are
4000 V core 2: black with imprint V/L2 cadmium-free and contain no silicone
Minimum bending radius core 3: black with imprint W/L3/D/L- and free from substances harmful to
flexing 15x cable control cores the wetting properties of lacquers
fixed installation 5x cable TOPSERV 108 PVC without control cores Tests
min. 100.000 cycles TOPSERV 112 PVC with 1 control cores PVC sheath flame retardant acc. to
acc. to Siemens DIN EN 60332-1-1 to -1-3
core 1: black with imprint BR1 (VDE 0482-332-1-1 to -1-3)
core 2: white with imprint BR2
acc. to Lenze
core 1: brown with imprint BR1
core 2: white with imprint BR2
TOPSERV119 PVC with 2 control cores
pair 1: black with number no. 5+6
pair 2: black with number no. 7+8
GN-YE conductor
Screening of the control cores in pairs
wrapped with tinned copper braid
Power supply cores laid up
with optimal lay length and
stabilising filler N
Fleece wrapping facilitates sliding
Overall screening from tinned copper
braid, optimal coverage approx. 85%
Outer sheath of PVC
Sheath colour orange (RAL 2003)

Note
For a corresponding encoder cables please check chapter TOPGEBER 511 PVC
For highly flexible, drag chain capable servo cables please check chapter TOPSERV PUR
Brackets ( ) indicate screen
DESINA explanation see introduction
SIEMENS product designations 6FX 5008-plus are registered trademarks of Siemens AG and are to be used only for purposes of comparison
Lenze product designations are registered trademarks of Lenze AG and are to be used only for purposes of comparison
Bosch Rexroth product designations INK are registered trademarks of Bosch Rexroth AG and are to be used only for purposes of comparison

Application
The combination of supply cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision servomotors,
as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting cables. These requirements
are met to a high degree by these cables. The cables have an additional overall screen to ensure EMC compatibility, i.e. for protection against
electromagnetic interference. Production is based on the specifications of established manufacturers of servo-drives and controls, as well as on various
VDE, UL and CSA standards.
Applications include machine, plant and robot construction, automation, drive, control and production engineering.
Attractive for export-oriented mechanical and system engineering.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Continuation

465
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPSERV PVC Motor and servo cables for fixed or not constantly
movements 0,6/1 kV, according to Siemens 6FX5008, Lenze, Bosch Rexroth
TOPSERV 108 PVC, acc.to Siemens 6FX5008
Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
707250 ( 4 G 1,5) Siemens 6FX5008-1BB11 Orange RAL 2003 8,0 78,0 118,0 16
707251 ( 4 G 2,5) Siemens 6FX5008-1BB21 Orange RAL 2003 9,6 130,0 180,0 14
707252 ( 4 G 4) Siemens 6FX5008-1BB31 Orange RAL 2003 11,0 198,0 264,0 12
707253 ( 4 G 6) Siemens 6FX5008-1BB41 Orange RAL 2003 13,1 288,0 382,0 10
707254 ( 4 G 10) Siemens 6FX5008-1BB51 Orange RAL 2003 19,3 463,0 764,0 8
707255 ( 4 G 16) Siemens 6FX5008-1BB61 Orange RAL 2003 23,3 701,0 1218,0 6
707256 ( 4 G 25) Siemens 6FX5008-1BB25 Orange RAL 2003 26,9 1068,0 1670,0 4
707257 ( 4 G 35) Siemens 6FX5008-1BB35 Orange RAL 2003 30,3 1449,0 2139,0 2
707258 ( 4 G 50) Siemens 6FX5008-1BB50 Orange RAL 2003 34,5 2096,0 2991,0 1

TOPSERV 112 PVC, acc.to Siemens 6FX5008


Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
707280 ( 4 G 1,5 + (2 x 1,5)) Siemens 6FX5008-1BA11 Orange RAL 2003 10,4 140,0 206,0 16
707281 ( 4 G 2,5 + (2 x 1,5)) Siemens 6FX5008-1BA21 Orange RAL 2003 12,0 185,0 269,0 14
707282 ( 4 G 4 + (2 x 1,5)) Siemens 6FX5008-1BA31 Orange RAL 2003 13,6 257,0 377,0 12
707283 ( 4 G 6 + (2 x 1,5)) Siemens 6FX5008-1BA41 Orange RAL 2003 15,6 348,0 485,0 10
707284 ( 4 G 10 + (2 x 1,5)) Siemens 6FX5008-1BA51 Orange RAL 2003 21,0 502,0 887,0 8
707285 ( 4 G 16 + (2 x 1,5)) Siemens 6FX5008-1BA61 Orange RAL 2003 24,1 741,0 1276,0 6
707286 ( 4 G 25 + (2 x 1,5)) Siemens 6FX5008-1BA25 Orange RAL 2003 28,3 1100,0 1716,0 4
707287 ( 4 G 35 + (2 x 1,5)) Siemens 6FX5008-1BA35 Orange RAL 2003 31,4 1498,0 2290,0 2
707288 ( 4 G 50 + (2 x 1,5)) Siemens 6FX5008-1BA50 Orange RAL 2003 34,5 2500,0 2934,0 1

TOPSERV 112 PVC, acc.to Lenze


Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
707221 ( 4 G 1 + (2 x 0,5)) Lenze - Orange RAL 2003 9,5 88,0 143,0 17
707222 ( 4 G 1,5 + (2 x 0,5)) Lenze - Orange RAL 2003 11,0 106,0 187,0 16
707223 ( 4 G 2,5 + (2 x 0,5)) Lenze - Orange RAL 2003 12,3 152,0 233,0 14
707224 ( 4 G 4 + (2 x 1,0)) Lenze - Orange RAL 2003 14,6 229,0 382,0 12
707225 ( 4 G 6 + (2 x 1,0)) Lenze - Orange RAL 2003 16,7 312,0 491,0 10
710054 ( 4 G 10 + (2 x 1,0)) Lenze - Orange RAL 2003 19,8 484,0 731,0 8
710055 ( 4 G 16 + (2 x 1,0)) Lenze - Orange RAL 2003 23,3 729,0 1033,0 6

TOPSERV 119 PVC, acc.to Bosch Rexroth


Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
707290 ( 4 G 1 + 2 x (2 x 0,75)) Bosch Rexroth INK-0653 Orange RAL 2003 11,2 130,0 208,0 -
707291 ( 4 G 1,5 + 2 x (2 x 0,75)) Bosch Rexroth INK-0650 Orange RAL 2003 11,5 155,0 229,0 -
707292 ( 4 G 2,5 + 2 x (2 x 1,0)) Bosch Rexroth INK-0602 Orange RAL 2003 13,5 216,0 321,0 -
707293 ( 4 G 4 + (2 x 1,0) + (2 x 1,5)) Bosch Rexroth INK-0603 Orange RAL 2003 15,5 297,0 432,0 -
707294 ( 4 G 6 + (2 x 1,0) + (2 x 1,5)) Bosch Rexroth INK-0604 Orange RAL 2003 17,3 374,0 587,0 -
707295 ( 4 G 10 + (2 x 1,0) + (2 x 1,5)) Bosch Rexroth INK-0605 Orange RAL 2003 21,2 545,0 910,0 -
707296 ( 4 G 16 + 2 x (2 x 1,5)) Bosch Rexroth INK-0606 Orange RAL 2003 25,0 804,0 1334,0 -

Dimensions and specifications may be changed without prior notice. (RN07)

Suitable HELUTEC Signal and power connectors


can be found in our Cable Accessories catalogue.

466
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPGEBER 511 PVC Feedback cables according to Siemens-,


Lenze- or Bosch Rexroth Standard with PVC-sheath for fixed or not constantly
movements

Technical data Cable structure Properties


Special PVC feedback cable acc. to UL AWM Copper-conductor bare or tinned to Outer sheath of PVC, oilresistant
style 20233 and CSA DIN VDE 0295 cl.6, extra fine-wire, Optimum compliance with requirements
Temperature range IEC 60228 cl.6 for elect romagnetic compatibility (EMC) by
flexing -0C to +60C Core insulation of special polypropylene approx. 85% coverage from the braided
fixed installation -20C to +80C Core colours on request screen
Nominal voltage Overall screening of tinned copper wire These cables are produced to high quality
acc. to Siemens 30 V braid with tinned drain wire, coverage specifications and conform to the
acc. to Bosch Rexroth and Lenze 300 V approx. 85% DESINA-standard
A.c. test voltage, 50 Hz Polyester foil The materials used in manufacture are
core/core 1500 V Outer sheath of PVC cadmium-free and contain no silicone
core/screen 1000 V Sheath colour green (RAL 6018) and free from substances harmful to
Minimum bending radius acc. to DESINA or orange the wetting properties of lacquers
flexing 15x cable Tests
fixed installation 6x cable PVC sheath flame retardant acc. to
min. 100.000 cycles DIN EN 60332-1-1 bis -1-3
(VDE 0482-332-1-1 bis -1-3)

Note
For a corresponding motor- and servocables please check chapter TOPSERV PVC
For drag chain capable encoder cables please check chapter TOPGEBER 512 PUR
Brackets ( ) indicate screen.
SIEMENS product designations 6FX 5008-... are registered trademarks of Siemens AG and are to be used only for purposes of comparison.
INDRAMAT product designations INK- are registered trademarks of Bosch-Rexroth AG and are to be used only for purposes of comparison.
LENZE product designations are registered trademarks of LENZE AG, and are to be used only for purposes of comparison.
DESINA: Explanation: see introduction.

Application
Low cost alternativ to Motorcables with PUR Sheath for fix instalation or occasional moving applications. These low-capacitance incremental encoder N
cables or position feedback cables transmit the control pulses for positioning and operating characteristics of servomotors. These cables are used as
connecting cables for tachos, brakes and pulse generators in industrial equipment, machine tools, control and automation equipment.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.


no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
707417 ( 4 x 2 x 0,34 + 4 x 0,5) Siemens 6FX 5008-1BD21 Green 8,9 70,3 117,8 -
707389 ( 3 x (2 x 0,14) + 4 x 0,14 + 2 x 0,5) Siemens 6FX 5008-1BD41 Green 8,8 58,0 118,9 -
707390 (3 x (2 x 0,14) + 4 x 0,14 + 4 x 0,25 + 2 x 0,5) Siemens 6FX 5008-1BD51 Green 9,6 70,7 137,7 -
803672 (2 x 2 x 0,22 + 1 x 2 x 0,34) Siemens 6FX 5008-2DC00 Green 6,9 38,0 61,0 -
802471 (2 x 2 x 0,22) Siemens 6FX 5008-1DC00 Green 6,9 35,0 71,0 -
705461 ( 4 x 2 x 0,25 + 2 x 0,5) Bosch Rexroth INK-0448 Orange 8,4 50,0 99,0 -
707392 ( 4 x 2 x 0,25 + 2 x 1,0) Bosch Rexroth INK-0209 Orange 8,8 64,0 119,0 -
707394 (4 x 2 x 0,14 + 4 x 1,0 + (4 x 0,14)) Bosch Rexroth INK-0532 Orange 9,7 86,0 149,0 -
707077 3 x (2 x 0,14) + (2 x 0,5) Lenze - Green 9,3 54,0 95,0 -
707397 4 x (2 x 0,14) + (2 x 1,0) Lenze - Green 11,0 70,0 145,0 -
707398 3 x (2 x 0,14) + (3 x 0,14) Lenze - Green 9,2 41,0 102,0 -

Dimensions and specifications may be changed without prior notice. (RN07)

Suitable HELUTEC Signal and power connectors


can be found in our Cable Accessories catalogue.

467
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPSERV PUR high flexible motor and servo cable for


drag chain 0,6/1 kV, for example according to Siemens 6FX8008PLUS,
Lenze, Bosch Rexroth

Technical data Cable structure Properties


Special PUR drag chain cable Bare copper-conductor, to Low adhesion, flame retardant, extremely
acc. to UL AWM Style 21223 or DIN VDE 0295 cl.6, extra fine-wire, abrasion resistant, halogen-free, resistant
20234 CSA AWM IEC 60228 cl.6 to UV, oil, hydrolysis and microbial attack
VDE-recognized Core insulation halogen-free PP PUR sheath
Temperature range Core identification Optimized insulation materials ensure
flexing -30C to +80C power supply cores resistance to oils (including mineral oils),
fixed installation -40C to +90C core 1: black with imprint U/L1/C/L+ greases, coolants, hydraulic fluids as well
Nominal voltage core 2: black with imprint V/L2 as many alkalis and solvents.
VDE U0/U 600/1000 V core 3: black with imprint W/L3/D/L- Optimum compliance with requirements
UL/CSA 1000 V control cores for electromagnetic compatibility (EMC) by
A.c. test voltage, 50 Hz TOPSERV 109 PUR without control cores approx. 85% coverage from the braided
4000 V TOPSERV 113 PUR with 1 control cores screen
Insulation resistance acc. to Siemens These cables are produced to high quality
min. 20 MOhm x km core 1: black with imprint BR1 specifications and conform to the
Coupling resistance core 2: white with imprint BR2 DESINA standard.
max. 250 Ohm/km acc. to Lenze The materials used in manufacture are
Minimum bending radius core 1: brown with imprint BR1 cadmium-free and contain no silicone
flexing 7,5x cable core 2: white with imprint BR2 and free from substances harmful to
fixed installation 4x cable TOPSERV121 PUR with 2 control cores the wetting properties of lacquers
pair 1: black with number no. 5+6 Resistant to cleaning and disinfecting
pair 2: black with number no. 7+8 agents acc. to
GN-YE conductor
Screening of the control cores in pairs
wrapped with tinned copper braid
Power supply cores laid up Tests
with optimal lay length and PUR outer sheath self-extinguishing and
stabilising filler flame retardant to DIN VDE 0482-332-1-2,
Fleece wrapping facilitates sliding DIN EN 60332-1-2, IEC 60332-1 (equivalent
Overall screening from tinned copper DIN VDE 0472 part 804 test method B)
braid, optimal coverage approx. 85%
Outer sheath of PUR
Sheath colour orange (RAL 2003)

Note
For a corresponding encoder cables please check chapter TOPGEBER 512 PUR
For servo cables with non or only slight drag chain application please check chapter TOPSERV PVC
Brackets ( ) indicate screen
DESINA explanation see introduction
SIEMENS product designations 6FX 5008-plus are registered trademarks of Siemens AG and are to be used only for purposes of comparison
Lenze product designations are registered trademarks of Lenze AG and are to be used only for purposes of comparison
Bosch Rexroth product designations INK are registered trademarks of Bosch Rexroth AG and are to be used only for purposes of comparison

Application
The combination of supply cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision servomotors,
as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting cables. These requirements
are met to a high degree by these cables. The cables have an additional overall screen to ensure EMC compatibillity, i. e. for protection against
electromagnetic interference. Production is based on the specifications of established manufacturers of servo-drives and controls, as well as on various
VDE, UL and CSA standards. Applications include machine, plant and robot construction, automation, drive, control and production engineering.
Attractive for export-oriented mechanical and system engineering. Please observe applicable installation regulations for use in energy supply chains.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Continuation

468
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPSERV PUR high flexible motor and servo cable for


drag chain 0,6/1 kV, for example according to Siemens 6FX8008PLUS,
Lenze, Bosch Rexroth
TOPSERV 109 PUR, acc.to Siemens 6FX8008PLUS
Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
75943 ( 4 G 1,5) Siemens 6FX8008-1BB11 Orange RAL 2003 8,9 90,0 142,0 16
75944 ( 4 G 2,5) Siemens 6FX8008-1BB21 Orange RAL 2003 10,7 132,0 206,0 14
75945 ( 4 G 4) Siemens 6FX8008-1BB31 Orange RAL 2003 12,2 204,0 290,0 12
75946 ( 4 G 6) Siemens 6FX8008-1BB41 Orange RAL 2003 14,5 315,0 423,0 10
75947 ( 4 G 10) Siemens 6FX8008-1BB51 Orange RAL 2003 17,5 488,0 672,0 8
75948 ( 4 G 16) Siemens 6FX8008-1BB61 Orange RAL 2003 21,6 769,0 1038,0 6
75949 ( 4 G 25) Siemens 6FX8008-1BB25 Orange RAL 2003 25,2 1100,0 1495,0 4
75950 ( 4 G 35) Siemens 6FX8008-1BB35 Orange RAL 2003 28,6 1510,0 1936,0 2
75951 ( 4 G 50) Siemens 6FX8008-1BB50 Orange RAL 2003 33,4 2133,0 2774,0 1
700437 ( 4 G 70) Siemens 6FX8008-1BB70 Orange RAL 2003 39,9 3029,0 3803,0 2/0
700897 ( 4 G 95) Siemens - Orange RAL 2003 49,5 4606,0 5102,0 3/0

TOPSERV 113 PUR, acc.to Siemens 6FX8008PLUS


Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
78948 ( 4 G 1,5 + (2 x 1,5)) Siemens 6FX8008-1BA11 Orange RAL 2003 11,6 148,0 233,0 16
78949 ( 4 G 2,5 + (2 x 1,5)) Siemens 6FX8008-1BA21 Orange RAL 2003 13,2 187,0 315,0 14
78950 ( 4 G 4 + (2 x 1,5)) Siemens 6FX8008-1BA31 Orange RAL 2003 14,8 268,0 403,0 12
78951 ( 4 G 6 + (2 x 1,5)) Siemens 6FX8008-1BA41 Orange RAL 2003 16,3 358,0 555,0 10
78952 ( 4 G 10 + (2 x 1,5)) Siemens 6FX8008-1BA51 Orange RAL 2003 19,5 584,0 769,0 8
75956 ( 4 G 16 + (2 x 1,5)) Siemens 6FX8008-1BA61 Orange RAL 2003 23,1 825,0 1207,0 6
75957 ( 4 G 25 + (2 x 1,5)) Siemens 6FX8008-1BA25 Orange RAL 2003 26,8 1283,0 1642,0 4
75958 ( 4 G 35 + (2 x 1,5)) Siemens 6FX8008-1BA35 Orange RAL 2003 30,9 1850,0 2120,0 2
75959 ( 4 G 50 + (2 x 1,5)) Siemens 6FX8008-1BA50 Orange RAL 2003 34,2 2540,0 2918,0 1

TOPSERV 113 PUR, acc.to Lenze


Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
707228 ( 4 G 1 + (2 x 0,5)) Lenze - Orange RAL 2003 10,5 88,0 166,0 16
707229 ( 4 G 1,5 + (2 x 0,5)) Lenze - Orange RAL 2003 11,5 106,0 206,0 16
707230 ( 4 G 2,5 + (2 x 0,5)) Lenze - Orange RAL 2003 13,2 152,0 268,0 14
707231 ( 4 G 4 + (2 x 1,0)) Lenze - Orange RAL 2003 14,6 229,0 387,0 12
707232 ( 4 G 6 + (2 x 1,0)) Lenze - Orange RAL 2003 17,6 333,0 523,0 10
707746 ( 4 G 10 + (2 x 1,0)) Lenze - Orange RAL 2003 20,1 508,0 766,0 8
707747 ( 4 G 16 + (2 x 1,0)) Lenze - Orange RAL 2003 23,8 751,0 1174,0 6

TOPSERV 113 PUR


Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
77376 ( 4 G 1 + (2 x 0,75)) - - Orange RAL 2003 11,5 134,0 250,0 17
700199 ( 4 G 1,5 + (2 x 0,5)) - - Orange RAL 2003 11,5 127,0 240,0 16
74506 ( 4 G 1,5 + (2 x 1,0)) - - Orange RAL 2003 11,1 138,0 212,0 16
74507 ( 4 G 2,5 + (2 x 1,0)) - - Orange RAL 2003 12,5 177,0 274,0 14
74508 ( 4 G 4 + (2 x 1,0)) - - Orange RAL 2003 14,3 258,0 378,0 12
74514 ( 4 G 6 + (2 x 1,0)) - - Orange RAL 2003 16,2 348,0 493,0 10
74509 ( 4 G 10 + (2 x 1,0)) - - Orange RAL 2003 19,0 574,0 736,0 8
74510
74511
( 4 G 16 + (2 x 1,0))
( 4 G 25 + (2 x 1,0))
-
-
-
-
Orange RAL 2003
Orange RAL 2003
22,2
26,2
815,0
1273,0
1071,0
1616,0
6
4
N
74512 ( 4 G 35 + (2 x 1,0)) - - Orange RAL 2003 29,8 1840,0 2080,0 2
74513 ( 4 G 50 + (2 x 1,0)) - - Orange RAL 2003 33,7 2530,0 2854,0 1

TOPSERV 121 PUR, acc.to Bosch Rexroth


Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
706003 ( 4 G 0,75 + (2 x 0,5)) Bosch Rexroth INK-0670 Orange RAL 2003 9,2 77,0 138,0 17
73774 ( 4 G 1 + 2 x (2 x 0,75)) Bosch Rexroth INK-0653 Orange RAL 2003 11,5 148,0 254,0 17
76103 ( 4 G 1,5 + 2 x (2 x 0,5)) - - Orange RAL 2003 12,4 145,0 250,0 17
73579 ( 4 G 1,5 + 2 x (2 x 1,0)) - - Orange RAL 2003 12,6 182,0 262,0 16
700561 ( 4 G 1,5 + 2 x (2 x 0,75)) Bosch Rexroth INK-0650 Orange RAL 2003 12,2 170,0 290,0 16
73580 ( 4 G 2,5 + 2 x (2 x 1,0)) Bosch Rexroth INK-0602 Orange RAL 2003 14,6 229,0 336,0 14
78955 ( 4 G 2,5 + 2 x (2 x 1,5)) - - Orange RAL 2003 15,6 241,0 350,0 14
74094 ( 4 G 4 + 2 x (2 x 1,0)) - - Orange RAL 2003 16,2 312,0 475,0 12
700562 ( 4 G 4 + (2 x 1,0) + (2 x 1,5)) Bosch Rexroth INK-0603 Orange RAL 2003 16,0 318,0 485,0 12
78956 ( 4 G 4 + 2 x (2 x 1,5)) - - Orange RAL 2003 16,7 324,0 490,0 12
74095 ( 4 G 6 + 2 x (2 x 1,0)) - - Orange RAL 2003 18,2 376,0 606,0 10
700563 ( 4 G 6 + (2 x 1,0) + (2 x 1,5)) Bosch Rexroth INK-0604 Orange RAL 2003 18,8 398,0 615,0 10
78957 ( 4 G 6 + 2 x (2 x 1,5)) - - Orange RAL 2003 19,0 450,0 621,0 10
74096 ( 4 G 10 + 2 x (2 x 1,0)) - - Orange RAL 2003 21,5 609,0 905,0 8
700564 ( 4 G 10 + (2 x 1,0) + (2 x 1,5)) Bosch Rexroth INK-0605 Orange RAL 2003 22,4 610,0 915,0 8
78958 ( 4 G 10 + 2 x (2 x 1,5)) - - Orange RAL 2003 22,4 625,0 925,0 8
75978 ( 4 G 16 + 2 x (2 x 1,5)) Bosch Rexroth INK-0606 Orange RAL 2003 26,9 904,0 1226,0 6
75979 ( 4 G 25 + 2 x (2 x 1,5)) Bosch Rexroth INK-0607 Orange RAL 2003 28,0 1323,0 1595,0 4
75980 ( 4 G 35 + 2 x (2 x 1,5)) Bosch Rexroth INK-0667 Orange RAL 2003 32,5 1621,0 2196,0 2
700565 ( 4 G 50 + 2 x (2 x 2,5)) Bosch Rexroth INK-0668 Orange RAL 2003 37,0 2600,0 3000,0 1

Dimensions and specifications may be changed without prior notice. (RN07)

469
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPGEBER 512 PUR high flexible Feedback cable for


drag chain according to Siemens, Bosch Rexroth, Lenze and other
Standards

Technical data Cable structure Properties


Special PUR drag chain feedback cable tinned copper, to PUR outer sheath, low adhesion, extremely
acc. to UL AWM style 20233 and 20236 DIN VDE 0295 cl.6, extra fine-wire, abrasion resistant, halogen-free, resistant
and CSA BS 6360 cl.6, IEC 60228 cl.6 to UV-, oil-, hydrolysis and microbial attack
Temperature range Core insulation of special polypropylene Special feature: These cables are produced
flexing -30C to +80C Core colours on demand to high quality specifications and conform
fixed installation -40C to +80C Fleece wrapping facilitates sliding to the DESINA-standard
Nominal voltage Overall screening of tinned copper wire Due to the high grade special core
acc. to Siemens 30 V braid with tinned drain wire, coverage insulation, the PUR sheath and the highly
acc. to Bosch Rexroth and Lenze 300 V approx. 85% flexible conductor, these cables are ideally
further details on request Polyester foil suitable for use in drag chains and provide
A.c. test voltage, 50 Hz Outer sheath of PUR high functional reliability
core/core 2000 V Sheath colour green (RAL 6018) Optimum compliance with requirements
core/screen 1000 V acc. to DESINA or orange for electromagnetic compatibility (EMC) by
Mutual capacitance at 800 Hz approx. 85% coverage from the braided
core/core approx. 70 nF/km screen
core/screen approx. 110 nF/km Particularly attractive for export-oriented
Insulation resistance markets due to UL/CSA approval
min. 20 MOhm x km The materials used in manufacture are
Coupling resistance cadmium-free and contain no silicone
max. 250 Ohm and free from substances harmful to
Minimum bending radius the wetting properties of lacquers
flexing 10x cable Resistant to cleaning and disinfecting
fixed installation 6x cable agents acc. to

Note
For a corresponding motor- and servocables please check chapter TOPSERV PUR
Encoder cables for static application please check chapter TOPGEBER 511 PVC
Brackets ( ) indicate screen.
SIEMENS product designations 6FX 8008-... are registered trademarks of Siemens AG and are to be used only for purposes of comparison.
Bosch Rexroth product designations INK- are registered trademarks of Bosch-Rexroth AG and are to be used only for purposes of comparison.
DESINA: Explanation: see introduction.

Application
These low-capacitance incremental encoder cables or position feedback cables transmit the control pulses for positioning and operating characteristics
of servomotors. These cables are used as connecting cables for tachos, brakes and pulse generators in applications subjected to heavy mechanical
stresses in industrial equipment, machine tools, control and automation equipment. Please observe applicable installation regulations for use in energy
supply chains.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Continuation

470
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPGEBER 512 PUR high flexible Feedback cable for


drag chain according to Siemens, Bosch Rexroth, Lenze and other
Standards
Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
700655 ( 8 x 2 x 0,18) Siemens 6FX 8008-1BD11 Green 7,8 54,0 79,0 24
78081 ( 4 x 2 x 0,34 + 4 x 0,5) Siemens 6FX 8008-1BD21 Green 9,8 83,0 135,0 21
707400 ( 3 x (2 x 0,14) + 2 x 0,5) Siemens 6FX 8008-1BD31 Green 9,0 74,0 119,0 21
700657 ( 3 x (2 x 0,14) + 4 x 0,14 + 2 x 0,5) Siemens 6FX 8008-1BD41 Green 8,9 66,0 120,0 26
700540 ( 3 x (2 x 0,14) + 4 x 0,14 + 4 x 0,25 + 2 x 0,5) Siemens 6FX 8008-1BD51 Green 9,6 75,0 138,0 -
700654 ( 4 x 2 x 0,18) Siemens 6FX 8008-1BD61 Green 6,4 35,0 57,0 -
700653 ( 2 x 2 x 0,18) Siemens 6FX 8008-1BD71 Green 5,0 24,0 42,0 -
78079 ( 12 x 0,22) Siemens 6FX 8008-1BD81 Green 7,5 65,0 74,0 24
804767 ( 2 x 2 x 0,2 + 2 x 0,38) Siemens 6FX 8008-2DC00 Green 7,0 40,0 74,0 -
706333 ( 5 x 2 x 0,25 + 2 x 0,5) Berger Lahr - Green 8,8 69,0 127,0 24
705413 ( 3 x 2 x 0,25 + 2 x 0,5) Elau - Green 7,4 43,0 82,0 24
707403 ( 3 x 2 x 0,25) B+R - Green 6,5 31,0 60,0 24
707404 ( 5 x 2 x 0,14 + 2 x 0,5) B+R - Green 8,7 48,0 98,0 24
707405 3 x (2 x 0,14) + (2 x 0,5) Lenze - Green 9,8 42,0 98,0 24
707406 4 x (2 x 0,14) + (2 x 1,0) Lenze - Green 11,3 66,0 144,0 24
707407 3 x (2 x 0,14) + (3 x 0,14) Lenze - Green 10,3 41,0 127,0 24
702050 (4 x 2 x 0,25 + 2 x 1,0) Bosch Rexroth INK-0209 grn Green 8,8 64,0 99,0 24
78080 ( 4 x 2 x 0,25 + 2 x 0,5) Bosch Rexroth INK-0448 grn Green 8,5 51,0 106,0 24
77741 ( 9 x 0,5) Bosch Rexroth INK-0208 grn Green 8,8 69,0 124,0 20
707738 ( 4 x 2 x 0,25 + 2 x 1,0) Bosch Rexroth INK-0209 Orange 8,8 64,0 99,0 20
707739 ( 4 x 2 x 0,25 + 2 x 0,5) Bosch Rexroth INK-0448 Orange 8,5 51,0 106,0 20
707740 ( 9 x 0,5) Bosch Rexroth INK-0208 Orange 8,8 69,0 124,0 20
707408 (4 x 2 x 0,14 + 4 x 1,0 + (4 x 0,14)) Bosch Rexroth INK-0532 Orange 9,7 81,0 142,0 20
707418 (3 x (2 x 0,25) + 3 x 0,25 + 2 x 1,0) Bosch Rexroth INK-0280 Orange 9,0 84,0 134,7 20
707409 (2 x 2 x 0,25 + 2 x 0,5) Bosch Rexroth INK-0750 Orange 7,2 38,0 79,0 20
77743 ( 3 x (2 x 0,14) + 2 x (1 x 0,5)) Heidenhain - Green 8,4 81,0 109,0 -
79513 ( 4 x 2 x 0,14 + 4 x 0,5) Heidenhain - Green 8,5 52,0 100,0 26
707410 ( 3 x 2 x 0,14 + 2 x 1,0) Heidenhain - Green 9,1 72,0 132,0 26
700560 (4 x 2 x 0,14 + (4 x 0,14) + 4 x 0,5) Heidenhain - Green 8,3 67,0 104,0 -
77753 ( 10 x 0,14 + 2 x 0,5) Heidenhain - Green 7,2 43,0 83,0 26
78963 ( 5 x 2 x 0,14 + 2 x 0,5) Baumller - Green 9,0 72,0 98,0 26
78828 ( 3 x 2 x 0,25) - - Green 7,2 55,0 83,0 24
79613 ( 5 x 2 x 0,38 + 2 x 0,5) - - Green 8,6 69,0 130,0 21
77744 ( 3 x (2 x 0,14) + 2 x 1,0) - - Green 8,2 71,0 107,0 26
78372 ( 3 x 2 x 0,14 + 2 x 0,5) - - Green 7,2 35,0 67,0 26
77750 ( 4 x (2 x 0,25) + 2 x 1,0) - - Green 10,5 93,0 175,0 24
705221 ( 4 x 2 x 0,25) - - Green 7,5 39,0 88,0 24

Dimensions and specifications may be changed without prior notice. (RN07)

Suitable HELUTEC Signal and power connectors


can be found in our Cable Accessories catalogue.

471
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPSERV 600 VFD EMC-preferred type, high flexible motor


power supply cable, oil-resistant, NFPA 79 Edition 2012

Technical data Cable structure Properties


TPE motor supply cable acc. to Tinned copper conductor, extra fine wire self-extinguishing and flame retardant
UL-Std.1277 and UL-Std.2277 with AWG dimensions acc. to CSA FT4
Temperature range Core insualtion of special PVC The materials used in manufacture are
-25C to +90C with transparent nylon skin cadmium-free and contain no silicone
Nominal voltage Black cores with continuous white and free from substances harmful to
TC 600 V numbering the wetting properties of lacquers
WTTC 1000 V GN-YE conductor in the outer layer UV-resistant
Test voltage 4000 V Cores stranded in layers with Tests
Minimum bending radius optimal lay-length UL:
flexing 5x cable Fleece TC-ER, WTTC 1000 V, MTW, NFPA 79 2012,
permanently flexing 7,5 cable 1. Screening with special aluminium foil PLTC-ER (AWG 18 - AWG 12),
Coupling resistance 2. Screening with braid of tinned copper ITC-ER (AWG 18 - AWG 12) OIL RES I & II,
max. 250 Ohm/km wires, optimal coverage approx. 85% 90C dry / 75C wet, Cold Bend Test -40C
Separator Class 1 Div. 2 per NEC Art. 336, 392, 501
Outer sheath of special TPE CSA:
Sheath colour black (RAL 9005) or c (UL) CIC-TC FT4
orange (RAL 2003) AWM I/II A/B FT4
with length marking in feet
Note
VFD = Variable Frequency Drive

Application
Highly-flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage)
and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures. Approved to
NFPA 79 edition 2012 for open, unprotected installation on cable trays and from cable trays to the machine. The special TPE sheath is extremly resistant
to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes and in the earth.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Sheath colour black Sheath colour orange
Part no. No.cores Cross- Outer Cop. Weight Part no. No.cores Cross- Outer Cop. Weight
x AWG-No. section mm app. mm weight app. x AWG-No. section mm app. mm weight app.
kg / km kg / km kg / km kg / km
62607 4 x 18 0,963 9,9 38,0 163,0 62616 4 x 18 0,963 9,9 38,0 163,0
62608 4 x 16 1,31 11,4 51,0 184,0 62617 4 x 16 1,31 11,4 51,0 184,0
62609 4 x 14 2,08 12,5 80,0 197,0 62618 4 x 14 2,08 12,5 80,0 197,0
62610 4 x 12 3,31 14,0 127,0 266,0 62619 4 x 12 3,31 14,0 127,0 266,0
62611 4 x 10 5,26 17,1 230,0 401,0 62620 4 x 10 5,26 17,1 230,0 401,0
62612 4x8 8,37 22,3 384,0 669,0 62621 4x8 8,37 22,3 384,0 669,0
62613 4x6 13,31 25,4 614,0 917,0 62622 4x6 13,31 25,4 614,0 917,0
62614 4x4 21,21 30,1 960,0 1364,0 62623 4x4 21,21 30,1 960,0 1364,0
62615 4x2 33,6 35,3 1344,0 1990,0 62624 4x2 33,6 35,3 1344,0 1990,0

Dimensions and specifications may be changed without prior notice. (RN01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-MS-EP4

472
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPSERV 650 VFD EMC-preferred type, high flexible motor


power supply cable with control cores, oil-resistant, NFPA 79 Edition 2012

Technical data Cable structure Properties


TPE motor supply cable acc. to Tinned copper-conductor, extra fine-wire The materials used in manufacture are
UL-Std.1277 and UL-Std.2277 with AWG dimensions cadmium-free and contain no silicone
Temperature range Core insualtion of special PVC and free from substances harmful to
flexing -25C to +105C with transparent nylon skin the wetting properties of lacquers
Nominal voltage Core identification black cores with UV-resistant
TC 600 V continuous white numbering Tests
WTTC 1000 V - power supply cores no. 1-4 self-extinguishing and flame retardant
Test voltage - control cores no. 5+6 acc. to CSA FT4
power supply cores 4000 V GN-YE conductor in the outer layer UL:
control cores 2000 V Control cores screened in pairs with TC-ER, WTTC 1000 V, MTW, NFPA 79 2012,
Minimum bending radius plastic-coated aluminium foil, tinned PLTC-ER (AWG 18 - AWG 12),
flexing 5x cable drain wire ITC-ER (AWG 18 - AWG 12) OIL RES I & II,
permanently flexing 7,5x cable Control cores stranded in pairs and 90C dry / 75C wet, Cold Bend Test -40C
Coupling resistance laid up in layers with optimal lay-length Class 1 Div. 2 per NEC Art. 336, 392, 501
max. 250 Ohm/km with the power supply cores CSA:
1. Screen with plastic-coated c (UL) CIC-TC FT4
aluminium foil AWM I/II A/B FT4
2. Tinned copper braided screen,
approx. 85% coverage Note
Separator VFD = Variable Frequency Drive
Outer sheath of special TPE
Sheath colour black (RAL 9005)
or orange (RAL 2003)
with length marking in feet

Application
Highly flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage)
and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures. Approved to
NFPA 79 edition 2012 for open, unprotected installation on cable trays and from cable trays to the machine. The special TPE sheath is extremly resistant
to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes and in the earth.
N
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Sheath colour black
Part no. No. cores Cross- Outer Cop. Weight
x AWG-No. section mm app. mm weight app. kg / km
kg / km
59837 4x AWG 16 +2x AWG 18 1,31/ 0,824 13,0 88,0 259,0
59838 4x AWG 14 +2x AWG 18 2,08/ 0,824 14,0 133,0 370,0
59839 4x AWG 14 +2x AWG 14 2,08/ 2,08 14,6 159,0 399,0
59840 4x AWG 12 +2x AWG 18 3,31/ 0,824 15,3 197,0 435,0
59841 4x AWG 12 +2x AWG 14 3,31/ 2,08 15,7 224,0 466,0
59842 4x AWG 10 +2x AWG 14 5,26/ 2,08 18,2 301,0 703,0
59843 4x AWG 8 +2x AWG 14 8,37/ 2,08 24,1 457,0 901,0
59844 4x AWG 6 +2x AWG 14 13,31/ 2,08 27,4 615,0 1275,0
59845 4x AWG 4 +2x AWG 14 21,21/ 2,08 33,4 1450,0 1861,0

Sheath colour orange


Part no. No. cores Cross- Outer Cop. Weight
x AWG-No. section mm app. mm weight app. kg / km
kg / km
59846 4x AWG 16 +2x AWG 18 1,31/ 0,824 13,0 88,0 259,0
59847 4x AWG 14 +2x AWG 18 2,08/ 0,824 14,0 133,0 370,0
59848 4x AWG 14 +2x AWG 14 2,08/ 2,08 14,6 159,0 399,0
59849 4x AWG 12 +2x AWG 18 3,31/ 0,824 15,3 197,0 435,0
59850 4x AWG 12 +2x AWG 14 3,31/ 2,08 15,7 224,0 466,0
59851 4x AWG 10 +2x AWG 14 5,26/ 2,08 18,2 301,0 703,0
59852 4x AWG 8 +2x AWG 14 8,37/ 2,08 24,1 457,0 901,0
59853 4x AWG 6 +2x AWG 14 13,31/ 2,08 27,4 615,0 1275,0
59854 4x AWG 4 +2x AWG 14 21,21/ 2,08 33,4 1450,0 1861,0

Dimensions and specifications may be changed without prior notice. (RN01)

473
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA

TOPSERV Hybrid hybrid cable for SICK Hiperface DSL motor

feedback systems

Technical data Cable structure Properties


TOPSERV PUR Bare copper-conductor, to low capacitance
Special PUR drag chain cable acc. to DIN VDE 0295 cl.6, extra fine-wire, PUR outer sheath: low adhesion, extremely
UL AWM Style 21223 CSA AWM IEC 60228 cl.6 abrasion resistant, halogen-free, resistant
Temperature range Core insulation halogen-free PP to UV-, oil-, hydrolysis and microbial attack
flexing -30C to +80C Core identification Optimum compliance with requirements
fixed installation -40C to +90C power supply cores for electromagnetic compatibility (EMC) by
Nominal voltage core 1: black with imprint U/L1/C/L+ approx. 85% coverage from the braided
VDE core 2: black with imprint V/L2 screen
power supply cores U0/U 600/1000 V core 3: black with imprint W/L3/D/L- These cables are produced to high quality
control cores U0/U 300/500 V control cores specifications and conform to the
UL/CSA 1000 V pair 1: black with number no. 5+6 DESINA standard.
A.c. test voltage, 50 Hz pair 2: white and blue The materials used in manufacture are
power supply cores 4000 V GN-YE conductor cadmium-free and contain no silicone
control cores 1000 V Screening of the control cores in pairs and free from substances harmful to
Insulation resistance wrapped with tinned copper braid the wetting properties of lacquers
min. 20 MOhm x km Power supply cores laid up Tests
Coupling resistance with optimal lay length and PUR outer sheath self-extinguishing and
max. 250 Ohm/km stabilising filler flame retardant to DIN VDE 0482-332-1-2,
Minimum bending radius Overall screening from tinned copper DIN EN 60332-1-2, IEC 60332-1 (equivalent
flexing 7,5x cable braid, optimal coverage approx. 85% DIN VDE 0472 part 804 test method B)
fixed installation 4x cable Outer sheath of PVC or PUR
min. 5 mio. cycles Sheath colour orange (RAL 2003)
acc. to DESINA

Note
The technical data for TOPSERV Hybrid PVC cables are available on request.

Application
The supply conductors for these cables are ideally combined with the control conductors for the brake function and the transmission of the Sick
Hiperface DSL protocols. Applications include machine, plant and robot construction. Please observe applicable installation regulations for use in
energy supply chains.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPSERV Hybrid PVC for fixed or not constantly movements
Part No.cores x Sheath Outer Cop. Weight AWG-No.
no. cross-sec. colour app. mm weight app. kg / km
mm kg / km
709930 (4G0,5 + (2x0,34) C + (2x26 AWG)) C Orange RAL 2003 9,3 72,0 123,0 26
709932 (4G1 + (2x0,75) C + (2x22 AWG)) C Orange RAL 2003 11,6 130,0 208,0 22
709933 (4G1,5 + (2x0,75) C + (2x22 AWG)) C Orange RAL 2003 12,2 152,0 248,0 22
709934 (4G2,5 + (2x1) C + (2x22 AWG)) C Orange RAL 2003 13,8 207,0 326,0 22
709935 (4G4 + (2x1) C + (2x22 AWG)) C Orange RAL 2003 15,3 273,0 415,0 22
709936 (4G6 + (2x1) C + (2x22 AWG)) C Orange RAL 2003 17,2 357,0 538,0 22
709937 (4G10 + (2x1,5) C + (2x22 AWG)) C Orange RAL 2003 20,3 530,0 752,0 22
709938 (4G16 + (2x1,5) C + (2x22 AWG)) C Orange RAL 2003 22,6 768,0 1005,0 22

TOPSERV Hybrid PUR, high flexible for drag chain


Part No.cores x Sheath Outer Cop. Weight AWG-No.
no. cross-sec. colour app. mm weight app. kg / km
mm kg / km
709703 (4G0,5 + (2x0,34) C + (2x26 AWG)) C Orange RAL 2003 9,3 76,0 127,0 26
708543 (4G1 + (2x0,75) C + (2x22 AWG)) C Orange RAL 2003 11,6 133,0 212,0 22
710081 (4G1,5 + (2x0,75) C + (2x24 AWG)) C Orange RAL 2003 11,7 146,0 229,0 24
708544 (4G1,5 + (2x0,75) C + (2x22 AWG)) C Orange RAL 2003 12,7 155,0 269,0 22
708545 (4G2,5 + (2x1) C + (2x22 AWG)) C Orange RAL 2003 13,9 205,0 310,0 22
708546 (4G4 + (2x1) C + (2x22 AWG)) C Orange RAL 2003 15,7 280,0 420,0 22
708547 (4G6 + (2x1) C + (2x22 AWG)) C Orange RAL 2003 18,0 363,0 540,0 22
708548 (4G10 + (2x1,5) C + (2x22 AWG)) C Orange RAL 2003 21,0 538,0 760,0 22
709705 (4G16 + (2x1,5) C + (2x22 AWG)) C Orange RAL 2003 23,4 775,0 1020,0 22

Dimensions and specifications may be changed without prior notice.

474
UL/CSA HEAT-RESISTANT CABLES
Cables according to international Approvals / Heat resistant Cables UL/CSA

SiHF UL/CSA halogen-free, 150C/ 600 V, two-approvals silicon multicore cable

Technical data Cable structure Properties


Special silicone multicore cable with higher Tinned copper conductors to DIN VDE 0295 Advantages
heat-resistance range to UL Style 4476 and cl.5, BS 6360 cl.5 and IEC 60228 cl.5 Hardly changes of dielectric strength and
CSA AWM II A/B Core insulation of silicone the insulation resistance also at high
Temperature range Core identification to DIN VDE 0293-308 temperatures, high ignition or flash point,
VDE -60C to +180C colour coded or black cores with in case of fire, forms an insulating layer of
(up to +220C for short time) continuous white numbering SiO2
UL/CSA -50C to +150C For 2-cores brown, blue Resistant to
Nominal voltage Cores stranded in layers with High molecular oils, fats from vegetables
VDE U0/U 300/500 V optimal lay-length and animals, alcohols, plasticizers and
UL/CSA 600 V GN-YE conductor, 3 cores and above clophenes, diluted acids, lyes and salt
Test voltage 2000 V Outer sheath of silicone dissolution, oxidation substances, tropical
Breakdown voltage min. 5000 V Sheath colour black influences and weather, lake water, oxygen
Insulation resistance and UV
min. 200 MOhm x km Halogen-free
Minimum bending radius acc. to DIN VDE 0482 part 267/
flexing 7,5x cable DIN EN 50267-2-1/IEC 60754-1 (equivalent
fixed installation 4x cable DIN VDE 0472 part 815)
Radiation resistance Behaviour in fire no flame propagation
up to 20x106 cJ/kg (up to 20 Mrad) acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2,IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B),
CSA FT1
For laying as a fixed installation only in open
or ventilated pipe systems as well as in
ducts. Otherwise the mechanical properties
of the silicon are reduced by the enclosed
air at temperatures exceeding 90C.

Note
G = with green-yellow conductor
x = without green-yellow conductor
screened analogue type:
SiHF-C-Si UL/CSA , confer page 478

Application
UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. They are heat-resistant for
permanent temperature up to +180C, for short time operation up to +220C. The good performance of the environmental resistant properties means
that silicone cables can be used at temperatures down to -60C. Silicone cables are halogen-free cables and are especially suited for installation in
power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement
factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
23214 2 x 0,5 20 7,7 9,6 73,0 23226 2x1 18 8,2 19,2 88,0
23215 3 G 0,5 20 8,1 14,4 82,0 23227 3G1 18 9,0 28,2 111,0
23216 4 G 0,5 20 8,8 19,2 98,0 23228 4G1 18 10,0 38,4 130,0
23217 5 G 0,5 20 9,4 24,0 120,0 23229 5G1 18 10,6 48,0 161,0
23218 6 G 0,5 20 10,4 28,8 131,0 23230 6G1 18 11,4 57,6 182,0
23219 7 G 0,5 20 10,4 33,6 140,0 23231 7G1 18 11,4 67,2 198,0
23220 8 G 0,5 20 10,8 38,4 183,0 23232 8G1 18 12,4 76,8 251,0
23221 10 G 0,5 20 12,8 48,0 201,0 24010 9G1 18 13,2 86,0 277,0
23222 12 G 0,5 20 13,4 57,6 241,0 23233 10 G 1 18 13,2 96,0 304,0
23223 16 G 0,5 20 13,9 76,8 269,0 23234 12 G 1 18 14,4 115,2 343,0
23224 18 G 0,5 20 14,4 86,4 311,0 23235 16 G 1 18 15,7 153,6 441,0
23225 25 G 0,5 20 16,8 120,0 401,0 23236 18 G 1 18 16,6 172,8 492,0
23237 25 G 1 18 19,1 240,0 617,0

Continuation

476
Cables according to international Approvals / Heat resistant Cables UL/CSA

SiHF UL/CSA halogen-free, 150C/ 600 V, two-approvals silicon multicore cable


Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
23238 2 x 1,5 16 9,1 28,8 117,0 23270 2x6 10 14,4 115,2 284,0
23239 3 G 1,5 16 9,6 43,2 131,0 23271 3G6 10 15,1 172,8 392,0
23240 4 G 1,5 16 10,6 57,6 166,0 23272 4G6 10 16,4 230,4 492,0
23241 5 G 1,5 16 11,4 72,0 198,0 23273 5G6 10 18,2 288,0 610,0
23242 6 G 1,5 16 12,4 86,4 240,0 23274 7G6 10 21,1 403,2 681,0
23243 7 G 1,5 16 12,4 100,8 261,0 23275 2 x 10 8 18,0 192,0 405,0
23244 8 G 1,5 16 13,9 115,2 298,0 23276 3 G 10 8 18,9 288,0 620,0
23245 10 G 1,5 16 16,1 144,0 359,0 23277 4 G 10 8 20,0 384,0 741,0
23246 12 G 1,5 16 16,6 172,6 431,0 23278 5 G 10 8 22,1 480,0 914,0
23247 14 G 1,5 16 18,0 201,6 520,0 23279 7 G 10 8 24,9 672,0 1164,0
23248 16 G 1,5 16 20,0 230,4 569,0 23280 2 x 16 6 20,9 307,2 441,0
23249 18 G 1,5 16 20,9 259,2 652,0 23281 3 G 16 6 22,8 460,8 501,0
23250 20 G 1,5 16 21,8 288,0 724,0 23282 4 G 16 6 24,9 614,4 623,0
23251 25 G 1,5 16 24,0 345,6 925,0 23283 5 G 16 6 26,9 768,0 971,0
23252 41 G 1,5 16 29,2 590,4 1440,0 23284 7 G 16 6 28,1 1075,3 1690,0
23253 2 x 2,5 14 9,8 48,0 141,0 23285 2 x 25 4 25,1 480,0 711,0
23254 3 G 2,5 14 10,4 72,0 174,0 23286 3 G 25 4 27,0 720,0 1210,0
23255 4 G 2,5 14 11,6 96,0 217,0 23287 4 G 25 4 32,1 960,0 1524,0
23256 5 G 2,5 14 12,4 120,0 271,0 23288 2 x 35 2 28,7 672,0 1140,0
23257 6 G 2,5 14 13,6 144,0 314,0 23289 3 G 35 2 30,6 1008,0 1523,0
23258 7 G 2,5 14 13,6 168,0 331,0 23290 4 G 35 2 32,9 1344,0 2217,0
23259 8 G 2,5 14 14,9 192,0 404,0
23260 10 G 2,5 14 17,2 240,0 495,0
23261 12 G 2,5 14 21,0 288,0 554,0
23262 16 G 2,5 14 22,6 384,0 725,0
23263 18 G 2,5 14 24,0 432,0 838,0
23264 25 G 2,5 14 28,8 600,0 1108,0
23265 2x4 12 10,9 76,8 190,0
23266 3G4 12 11,8 115,2 241,0
23267 4G4 12 12,9 153,6 304,0
23268 5G4 12 14,5 192,0 384,0
23269 7G4 12 17,8 268,8 527,0

Dimensions and specifications may be changed without prior notice. (RN03)

Suitable accessories can be found in Chapter X.


Cable protection tube - HTP

477
Cables according to international Approvals / Heat resistant Cables UL/CSA

SiHF-C-Si UL/CSA halogen-free, 150C/ 600 V, two-approvals silicon


multicore cable, Cu-screened, EMC-preferred type

Technical data Cable structure Properties


Special silicone multicore cable with higher Tinned copper conductors to Advantages
heat-resistance range to UL Style 4476 and DIN VDE 0295 cl.5, BS 6360 cl.5 and Hardly changes of dielectric strength and
CSA AWM II A/B IEC 60228 cl.5 the insulation resistance, also at high
Temperature range Core insulation of silicone temperatures high ignition or flash point,
VDE -60C to +180C Core identification to DIN VDE 0293-308 in case of fire, forms an insulating layer of
(up to +220C for short time) colour coded or black cores with SiO2
UL/CSA -50C to +150C continuous white numbers Resistant to
Nominal voltage For 2-cores brown, blue High molecular oils, fats from vegetables
VDE U0/U 300/500 V Cores stranded in layers with and animals, alcohols, plasticizers and
UL/CSA 600 V optimal lay-length clophenes, diluted acids, lyes and salt
Test voltage 2000 V GN-YE conductor, 3 cores and above dissolution, oxidation substances, tropical
Breakdown voltage min. 5000 V Foil separator influences and weather, lake water, oxygen
Insulation resistance Tinned copper braided screening, and UV
min. 200 MOhm x km approx. 85% coverage For laying as a fixed installation only in open
Minimum bending radius Outer sheath of silicone or ventilated pipe systems as well as in
flexing 10x cable Sheath colour black ducts. Otherwise the mechanical properties
fixed installation 5x cable Tests of the silicon are reduced by the enclosed
Coupling resistance Halogen-free air at temperatures exceeding 90C.
max. 250 Ohm/km acc. to DIN VDE 0482 part 267,
Radiation resistance DIN EN 50267-2-1, IEC 60754-1 Note
up to 20x106 cJ/kg (up to 20 Mrad) (equivalent DIN VDE 0472 part 815) G = with green-yellow conductor
Behaviour in fire x = without green-yellow conductor
no flame propagation acc. to AWG sizes are approximate equivalent
DIN VDE 0482-332-1-2, DIN EN 60332-1-2, values. The actual cross-section is in mm.
IEC 60332-1 (equivalent DIN VDE 0472 non-screened analogue type:
part 804 test method B), CSA FT1. SiHF UL/CSA, confer page 476

Application
UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of
the environmental resistant properties means that silicone cables can be used at temperatures down to -60C. Silicone cables are halogen-free cables
and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship
building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable.
An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore
flexible cable for such applications as given above.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
22637 2 x 0,5 20 9,0 55,5 94,0 22656 10 G 1,5 16 17,3 268,5 478,0
22638 3 G 0,5 20 9,3 60,8 104,0 22657 12 G 1,5 16 17,9 298,4 521,0
22639 4 G 0,5 20 9,7 66,5 125,0 22658 2 x 2,5 14 12,0 122,3 226,0
22640 5 G 0,5 18 10,1 81,6 149,0 22659 3 G 2,5 14 12,7 147,7 271,0
22641 7 G 0,5 20 10,5 92,2 168,0 22660 4 G 2,5 14 14,0 188,6 332,0
22642 10 G 0,5 20 13,2 124,0 237,0 22661 5 G 2,5 14 15,1 214,9 384,0
22643 12 G 0,5 20 13,4 134,4 260,0 22662 7 G 2,5 14 16,9 265,7 478,0
22644 2x1 18 9,5 66,7 130,0 22663 4G4 12 17,0 294,0 516,0
22645 3G1 18 9,6 86,2 151,0 22664 5G4 12 19,1 374,0 641,0
22646 4G1 18 10,6 96,8 169,0 22665 4G6 10 18,6 449,0 773,0
22647 5G1 18 11,6 108,3 198,0 22666 5G6 10 21,3 563,0 980,0
22648 7G1 18 12,1 141,2 236,0 22667 4 G 10 8 25,5 759,0 1284,0
22649 10 G 1 18 14,7 190,0 248,0
22650 12 G 1 18 15,1 209,8 364,0
22651 2 x 1,5 16 10,6 87,7 169,0
22652 3 G 1,5 16 11,0 103,5 191,0
22653 4 G 1,5 16 11,6 131,7 230,0
22654 5 G 1,5 16 13,1 148,5 272,0
22655 7 G 1,5 16 14,1 193,4 341,0

Dimensions and specifications may be changed without prior notice. (RN03)

478
UL/CSA ALLWEATHER CABLES & RUBBER CABLES
Cables according to international Approvals / Allweather and Rubber Cables UL/CSA

Rubber / Neoprene Control Cable type SJO and SO

Technical data Cable structure Properties


UL+CSA approved rubber/neoprene flexible Bare copper conductor to ASTM B-174 Resistant
cables Core insulation of synthetic rubber, Oil
Temperature range EPDM Wetness
-40C to +90C Core identification coloured UV-radiation
Nominal voltage Colour code
SJO 300 V 2 cores black, white Note
SO 600 V 3 cores black, white, green Note: SJO-18/2
Approvals 4 cores black, white, green, red 18 = AWG 18
UL-Std.62 Cores stranded in layers with 2 = No. of cores
CSA C22.2-49 optimal lay-length Supply lengths are on original reels of 76
Hemp or cotton filler m or 152 m or on drums of 305 m lengths.
Outer sheath of neoprene (oil resistant) Further Types also available: PVC control
Sheath colour black cables SJT, SJTO, ST, STO.

Application
As a flexible cord for mobile equipment for use in rougher conditions in the engines and mechanical engineering, dockyards, in agriculture, in cabins
and steel rolling mills and for export overseas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Nominal voltage 300 Volt, type SJO (90C)
Part no. No.cores Current Cond. make-up Outer Weight
x AWG-No. carrying n x wire app. mm app. kg / km
capacity
in Amp.
63010 2 x 18 7 16 x 0,3 7,8 65,0
63011 3 x 18 7 16 x 0,3 8,4 80,0
63012 4 x 18 7 16 x 0,3 9,2 95,0
63013 2 x 16 10 26 x 0,3 8,3 130,0
63014 3 x 16 10 26 x 0,3 9,0 148,0
63015 4 x 16 10 26 x 0,3 10,0 180,0
63016 2 x 14 15 41 x 0,3 9,4 195,0
63017 3 x 14 15 41 x 0,3 10,0 225,0
63018 4 x 14 15 41 x 0,3 10,7 288,0

Nominal voltage 600 Volt, type SO (90C)


Part no. No.cores Current Cond. make-up Outer Weight
x AWG-No. carrying n x wire app. mm app. kg / km
capacity
in Amp.
63034 2 x 18 7 16 x 0,3 10,0 70,0
63035 3 x 18 7 16 x 0,3 10,4 86,0
63036 4 x 18 7 16 x 0,3 11,0 110,0
63037 2 x 16 10 26 x 0,3 10,4 140,0
63038 3 x 16 10 26 x 0,3 11,0 155,0
63039 4 x 16 10 26 x 0,3 12,3 200,0
63040 2 x 14 15 41 x 0,3 13,5 200,0
63041 3 x 14 15 41 x 0,3 14,3 235,0
63042 4 x 14 15 41 x 0,3 15,3 300,0
63043 2 x 12 20 65 x 0,3 15,3 280,0
63044 3 x 12 20 65 x 0,3 16,2 310,0
63045 4 x 12 20 65 x 0,3 18,9 330,0
63046 2 x 10 25 105 x 0,3 16,4 305,0
63047 3 x 10 25 105 x 0,3 17,5 325,0
63048 4 x 10 25 105 x 0,3 19,0 365,0

Dimensions and specifications may be changed without prior notice. (RN04)

Suitable accessories can be found in Chapter X.


Cable tie - T-WS

480
Cables according to international Approvals / Allweather and Rubber Cables UL/CSA

H07RN-F/SOOW rubber-sheathed cable, harmonizised type

Technical data Cable structure Properties


Rubber-sheated cable H07RN-F acc. to Bare copper conductor, fine wire with Ozone-resistant
DIN VDE 0285-525-2-21 / AWG dimensions Weather and UV-resistant
DIN EN 50525-2-21 and UL-Std.62 Core insulation of rubber (EPR) Resistant to oils and greases
UL - SOOW Core identification
CSA - SOOW 3 cores: BU, BN
Temperature rang 4 cores: BN, BK, GY
HAR -25C to +60C 5 cores: BU, BN, BK, GY
UL/CSA -40C to +90C Cores stranded in layers with
Permissible operating temperature optimal lay-length
at the conductor +60C GN-YE conductor
Nominal voltage Outer sheath of rubber (CPE)
HAR U0/U 450/750 V Sheath colour black
UL/CSA 600 V
Test voltage 2500 V
Minimum bending radius
flexing 10x cable
fixed installation 7,5x cable

Application
Highly-standardised, heavy-duty rubber-sheated cable for use in practically all machines destined for export markets, in dry, damp, wet environments
and outdoors. As a feeder to transportable motors or machines, cranes, hoists, hand lamps and drilling machines.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part Cross- No.cores Current carrying Outer Cop. Weight Part Cross- No.cores Current carrying Outer Cop. Weight
no. section x capacity in ampere app. weight app. no. section x capacity in ampere app. weight app.
mm AWG-No. at 30C ambient mm kg / km kg / km mm AWG-No. at 30C ambient mm kg / km kg / km
temperature temperature
39025 1 3 x 17 10 9,6 29,0 130,0 39033 4 4 x 11 20 17,3 154,0 395,0
39026 1,5 3 x 15 13 10,2 43,0 165,0 39034 4 5 x 11 16 18,7 192,0 485,0
39027 1,5 4 x 15 10 11,4 58,0 200,0 39035 6 3 x 9 30 17,1 173,0 420,0

N
39028 1,5 5 x 15 8 13,1 72,0 240,0 39036 6 4 x 9 25 18,4 230,0 540,0
39029 2,5 3 x 13 18 14,0 72,0 235,0 39037 6 5 x 9 24 20,1 288,0 650,0
39030 2,5 4 x 13 15 15,1 96,0 290,0 39038 10 3 x 7 40 22,9 288,0 810,0
39031 2,5 5 x 13 12 16,9 120,0 345,0 39039 10 4 x 7 35 25,0 384,0 950,0
39032 4 3 x 11 25 16,0 115,0 320,0

Dimensions and specifications may be changed without prior notice. (RF01)

Suitable accessories can be found in Chapter X.


Cable tie - T-WS

481
UL/CSA REELING CABLES

482
Cables according to international Approvals / Trailing Cables UL/CSA

TROMMPUR-H trailing, halogen-free

Technical data Cable structure Properties


Trailing cable acc. to Bare copper-conductor, to PUR outer sheath, low adhesion, abrasion
UL AWM Style 20235 CSA/AWM DIN VDE 0295 cl.6, extra fine-wire, resistant, halogen-free, resistant to UV, oil,
Temperature range BS 6360 cl.6, IEC 60228 cl.6 hydrolysis and microbial attack
flexing -40C to +80C Core insulation of TPE Due to the PUR outer sheath, the cable is
fixed installation -50C to +80C Core identification to DIN VDE 0293 resistant against ozone and radiation, as well
Nominal voltage - up to 5 cores coloured as oils, greases and petrol
DIN VDE 600/1000 V - from 6 cores, black with continuous
UL 1000 V white numbering Note
A.c. test voltage, 50 Hz GN-YE conductor AWG sizes are approximate equivalent
core/core 4000 V Cores stranded around support element values. The actual cross-section is in mm.
Insulation resistance Polyester fleece wrapping
min. 20 MOhm x km Outer sheath of PUR
Speed of motion with integrated support braiding
up to 250 m/min Sheath colour yellow
Minimum bending radius
6x cable

Application
Significantly smaller external diameters, smaller bending radii and reduced weights compared to NSHTU cables enable the use of smaller drive motors
and drums, thus providing significant cost savings. Trailing cables are used for high mechanical stress, especially for applications with frequent winding
and unwinding with simultaneous tensile and torsional stress, for building machinery, conveyors and lifting systems, and cranes. They are used as
robust and all-weather resistant cables in the harshest operating environments in mining and in flexible handling equipment and railway motors. The
cables are suitable for installation in dry, damp and wet environments, as well as outdoors.
Notes
During installation and operation the tensile stress on the cable must not exceed 25 N/mm
Acceleration must not exceed 0,4 m/s
1 to 2 turns should remain on the drum during operation
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x


cross-sec.
Outer
app. mm
Cop.
weight
Weight
app. kg / km
AWG-No. Part no. No.cores x
cross-sec.
Outer
app. mm
Cop.
weight
Weight
app. kg / km
AWG-No.
N
mm kg / km mm kg / km
77144 4 G 1,5 10,2 58,0 157,0 16 77161 4G4 12,5 154,0 270,0 12
77145 5 G 1,5 10,8 72,0 176,0 16 77172 5G4 14,3 192,0 362,0 12
77146 7 G 1,5 12,9 101,0 245,0 16 77162 4G6 16,9 230,0 409,0 10
77147 12 G 1,5 18,4 173,0 337,0 16 77173 5G6 17,8 288,0 511,0 10
77148 18 G 1,5 18,6 259,0 526,0 16 77163 4 G 10 19,6 384,0 633,0 8
77149 24 G 1,5 21,3 345,6 662,0 16 77174 5 G 10 20,9 480,0 766,0 8
77150 30 G 1,5 24,6 432,0 901,0 16 77164 4 G 16 23,8 614,0 936,0 6
77151 42 G 1,5 26,5 604,8 1056,0 16 77175 5 G 16 25,3 768,0 1170,0 6
77152 4 G 2,5 11,7 96,0 208,0 14 77165 4 G 25 27,7 960,0 1485,0 4
77153 5 G 2,5 12,7 120,0 263,0 14 77166 4 G 35 30,1 1344,0 2115,0 2
77154 7 G 2,5 14,8 168,0 327,0 14 77167 4 G 50 35,2 1920,0 2600,0 1
77155 12 G 2,5 20,4 288,0 533,0 14 77168 4 G 70 40,3 2688,0 3700,0 2/0
77156 18 G 2,5 21,1 432,0 725,0 14 77169 4 G 95 50,6 3648,0 4800,0 3/0
77157 24 G 2,5 24,8 576,0 988,0 14 77170 4 G 120 53,0 4608,0 5900,0 4/0
77158 30 G 2,5 27,6 720,0 1242,0 14 77171 4 G 150 56,0 5760,0 7100,0 300 kcmil
77159 40 G 2,5 30,0 960,0 1500,0 14
77160 50 G 2,5 34,3 1200,0 1800,0 14

Dimensions and specifications may be changed without prior notice.

483
UL/CSA SINGLE CORES

484
Cables according to international Approvals / Single Conductors UL/CSA

UL-Style 1007, CSA TR 64 PVC single cores, 80C, 300 V

Technical data Cable structure Properties


PVC-single core to UL-Style and CSA-AWM Stranded copper conductor, tinned to Conditionally resistant to
UL-Style 1007 UL-Std.758 with AWG dimensions Oils
CSA-AWM I A/B or TR 64 Core insulation of PVC Solvents
Temperature range heat and damp resistant acc. to class 43 Acids
flexible -5C bis +80C tab.50.182 acc. to UL-Std.1581 Lyes
fixed installation -30C bis +80C The materials used in manufacture are
CSA-AWM I A/B or TR 64 +90C cadmium-free and contain no silicone
Nominal voltage 300 V and free from substances harmful to
Test voltage 2000 V the wetting properties of lacquers
Test voltage (Spark test) Tests
AWG 26-20 = 4 kV PVC self-extinguishing and flame retardant,
AWG 10-18 = 5 kV test method to UL VW-1, CSA FT1
Minimum bending radius
fixed installation 5x core Note
flexible 10x core Please complete the part number for
these cables by adding the suffix for
the colour required as per the list:
00 = green
01 = black
02 = blue
03 = brown
04 = red
05 = white
06 = grey
07 = violet
08 = yellow
09 = orange
10 = transparent
11 = pink
12 = beige
13 = green-yellow N
Due to design the constructional
alternations may the possible.
AWG 14 - AWG 10 to UL-Style 1569

Application
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. Connecting wires in machines
laid in protective tubes and flexible pipes and also for motors and transformators.
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
635xx 1 x 0,13 26 1,4 1,6 3,2 624xx 1 x 1,32 16 2,4 13,0 18,5
620xx 1 x 0,21 24 1,5 2,3 4,3 636xx 1 x 2,08 14 3,0 20,0 29,0
621xx 1 x 0,33 22 1,6 3,4 6,0 637xx 1 x 3,31 12 3,9 33,0 40,0
622xx 1 x 0,52 20 1,8 5,3 8,5 638xx 1 x 5,26 10 4,1 51,6 61,0
623xx 1 x 0,82 18 2,1 8,2 12,5

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

485
Cables according to international Approvals / Single Conductors UL/CSA

UL-Style 1569, CSA TR 64 PVC single cores, 105C, 300 V

Technical data Cable structure Properties


PVC-single core to UL-Style and CSA-AWM Stranded copper conductor, tinned to Conditionally resistant to
UL-Style 1569 UL-Std.758 with AWG dimensions Oils
CSA-AWM I A/B or TR 64 Core insulation of special PVC Solvents
Temperature range heat and damp resistant Acids
flexible -5C bis +105C class 43 tab.50.182 acc. to UL-Std.1581 Lyes
fixed installation -30C bis +105C The materials used in manufacture are
CSA-AWM I A/B or TR 64 +90C cadmium-free and contain no silicone
Nominal voltage 300 V and free from substances harmful to
Test voltage 2000 V the wetting properties of lacquers
Test voltage (Spark test) Tests
AWG 26-20 = 4 kV PVC self-extinguishing and flame retardant,
AWG 10-18 = 5 kV test method to UL VW-1, CSA FT1
Minimum bending radius
fixed installation 5x core Note
flexing 10x core Please complete the part number for
these cables by adding the suffix for
the colour required as per the list:
00 = green
01 = black
02 = blue
03 = brown
04 = red
05 = white
06 = grey
07 = violet
08 = yellow
09 = orange
10 = transparent
11 = pink
12 = beige
13 = green-yellow
Due to design the constructional
alternations may the possible.

Application
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. Connecting wires in machines
laid in protective tubes and flexible pipes and also for motors and transformators.
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
660xx 1 x 0,13 26 1,4 1,6 3,2 665xx 1 x 1,32 16 2,4 13,0 18,5
661xx 1 x 0,21 24 1,5 2,3 4,3 666xx 1 x 2,08 14 2,9 20,0 29,0
662xx 1 x 0,33 22 1,6 3,4 6,0 667xx 1 x 3,31 12 3,6 33,0 40,0
663xx 1 x 0,52 20 1,8 5,3 8,5 668xx 1 x 5,26 10 4,3 51,6 61,0
664xx 1 x 0,82 18 2,1 8,2 12,5

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

486
Cables according to international Approvals / Single Conductors UL/CSA

UL-Style 1015 PVC single core, 600 V

Technical data Cable structure Properties


PVC-single core as per UL AWM Style 1015/ Stranded copper conductor, tinned to Conditionally resistant to
MTW and CSA-AWM/TEW UL-Std.758 with AWG dimensions Oils
Temperature range AWG-sizes as per table below Solvents
flexible -5C to +105C Core insulation of PVC Acids
fixed installation -30C to +105C heat and damp resistant to Lyes
Temperature at conductor class 43 and CSA-C22.2 No. 210 UL VW-1 The materials used in manufacture are
UL/CSA max. +105C and CSA FT1, acc. to UL-Std.1581 cadmium-free and contain no silicone
Nominal voltage 600 V For structural reasons, constructive and free from substances harmful to
Test voltage (Spark test) changes are possible the wetting properties of lacquers
AWG 24 = 4 kV Tests
AWG 22 and 20 = 5 kV PVC self-extinguishing and flame
AWG 18 and 10 = 6 kV retardant, test method to UL VW-1,
AWG 8 = 7,5 kV CSA FT1
UL-type AWM+MTW 105C 600 V
CSA-type AWM+TEW 105C 600 V Note
Minimum bending radius Please complete the part number for
fixed installation 5x core these cables by adding the suffix for
flexible 10x core the colour required as per the list:
00 = green, 01 = black, 02 = blue,
03 = brown, 04 = red, 05 = white,
06 = grey, 07 = violet, 08 = yellow,
09 = orange, 10 = transparent, 11 = pink,
12 = beige, 13 = green-yellow,
14 = blue/white, 15 = dark blue,
27 = white/blue
(supply up to AWG 8)

Application
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. Connecting wires in machines
laid in predective tubes and flexible pipes and also for motors and transformators. UL bzw. CSA:
AWM = Appliance Wiring Material N
For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components.
UL-MTW: Machine Tool Wires
CSA-TEW: Equipment Lead Wires
MTW = Machine Tool Wire
For the electronical installation of machine tools and the relative control.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
601xx 1 x 0,21 24 2,2 2,3 8,0 613xx 1 x 33,61 2 11,3 317,0 380,0
602xx 1 x 0,33 22 2,4 3,2 10,0 614xx 1 x 42,38 1 13,3 399,0 500,0
603xx 1 x 0,52 20 2,5 5,0 12,0 615xx 1 x 53,47 1/0 13,6 500,0 615,0
604xx 1 x 0,81 18 2,8 7,9 16,0 616xx 1 x 67,4 2/0 15,5 631,0 750,0
605xx 1 x 1,31 16 3,1 12,6 22,0 617xx 1 x 84,97 3/0 17,5 792,0 900,0
606xx 1 x 2,08 14 3,5 20,7 31,0 618xx 1 x 107,17 4/0 19,0 996,0 1070,0
607xx 1 x 3,32 12 4,0 33,0 45,0 62501 1 x 127 250 kcmil 21,2 1178,0 1280,0
608xx 1 x 5,26 10 4,6 51,6 65,0 62601 1 x 152 300 kcmil 22,4 1410,0 1518,0
609xx 1 x 8,35 8 6,5 80,6 110,0 62701 1 x 178 350 kcmil 25,3 1645,0 1756,0
610xx 1 x 13,29 6 8,0 125,0 175,0 62801 1 x 203 400 kcmil 26,0 1902,0 2002,0
611xx 1 x 21,14 4 9,5 201,0 260,0 62901 1 x 254 500 kcmil 28,0 2345,0 2475,0
612xx 1 x 26,65 3 10,4 253,0 340,0

Dimensions and specifications may be changed without prior notice. (RN06)

487
Cables according to international Approvals / Single Conductors UL/CSA

THREENORM PVC single core, UL-Style 1013 and CSA 600 V

Technical data Cable structure Properties


PVC-single cores acc. to Bare copper fine wire stranded to The materials used in manufacture are
DIN VDE 0285-525-2-31, DIN VDE 0295 cl.5, BS 6360 cl.5, cadmium-free and contain no silicone
DIN EN 50525-2-31, UL-Style 1013 IEC 60228 cl.5, acc. to UL-Std.758 resp. and free from substances harmful to
and CSA, CSA-AWM I/A/B ASTM B 174 the wetting properties of lacquers
Temperature range Core insulation of PVC Tests
H05V-K/H07V-K compound type TI1 to PVC self-extinguishing and flame retardant
flexing +5C to +70C DIN VDE 0207-363-3/ DIN EN 50363-3 acc. to DIN VDE 0482-332-1-2,
fixed installation -10C to +70C acc. to UL-Std.1581, class 43, CSA-C 22.2 DIN EN 60332-1-2/IEC 60332-1 (equivalent
UL/CSA +90C No. 210 tab.12 class H DIN VDE 0472 part 804 test method B)
Nominal voltage Core identification to DIN VDE 0293 UL-VW-1, CSA FT1
up to 1 mm H05V-K: U0/U 300/500 V coloured
from 1,5 mm H07V-K: U0/U 450/750 V Note
UL/CSA 600 V AC Tinned conductor on request.
Test voltage AWG sizes are approximate equivalent
H05V-K/H07V-K 2000 V values. The actual cross-section is in mm.
Test voltage (Spark Test) The cross-sections 0,5 mm, 0,75 mm and
AWG 20 = 5 kV 1,0 mm are acc. to H05 V-K,
> AWG 20 = 6 kV the cross-sections 1,5 up to 120 mm
Insulation resistance acc. to H07 V-K.
min. 20 MOhm x km Type H05 V:
Minimum bending radius approved one-colour mark:
fixed installation for core : black, blue, brown, grey, orange, pink,
8 mm: 4x core red, turquoise, violet, white, green and
> 8-12 mm: 5x core yellow.
> 12 mm: 6x core Two-coloured mark in any combination of
the above individual colours.
Type H07 V:
approved mark: black, blue,
brown, grey, orange, pink, red, turquoise,
violet, white and green-yellow.
Other marks are available as (H).

Application
Three norms approved connecting jumper wire primarily designed for exportes, used in machine tools. This wire is used for internal wiring of switchboards
and electrical equipment. The approbation of HAR-UL-CSA AWM make possible an economical storekeeping and simplification of parts list.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05V-K
Cross-sec. Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
mm app. mm weight
/ AWG-no. kg / km
app. RAL 9005 - 5015 8003 3000 1013 7000 4005 1021 3015 6018 - 5010 2003 - -
Part no. 63815 63816 63817 63818 63819 63820 63821 63822 63823 63824 63825 63826 63827 63828 63829 63830
0,5 / 20 2,5 4,8
Part no. 63831 63832 63833 63834 63835 63836 63837 63838 63839 63840 63841 63842 63843 63844 63845 63846
0,75 / 19 2,65 7,2
Part no. 63847 63848 63849 63850 63851 63852 63853 63854 63855 63856 63857 63858 63859 63860 63861 63862
1 / 18 2,8 9,6

Continuation

488
Cables according to international Approvals / Single Conductors UL/CSA

THREENORM PVC single core, UL-Style 1013 and CSA 600 V


H07V-K
Cross-sec. Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
mm app. mm weight
/ AWG-no. kg / km
app. RAL 9005 - 5015 8003 3000 1013 7000 4005 1021 3015 6018 - 5010 2003 - -
Part no. 63863 63864 63865 63866 63867 63868 63869 63870 63871 63872 63873 63874 63875 63876 63877 63878
1,5 / 16 3,05 14,4
Part no. 63879 63880 63881 63882 63883 63884 63885 63886 63887 63888 63889 63890 63891 63892 63893 63894
2,5 / 14 3,6 24,0
Part no. 63895 63896 63897 63898 63899 63900 63901 63902 63903 63904 63905 63906 63907 63908 63909 63910
4 / 12 4,1 38,0
Part no. 63911 63912 63913 63914 63915 63916 63917 63918 63919 63920 63921 63922 63923 63924 63925 63926
6 / 10 4,8 58,0
Part no. 63927 63928 63929 63930 63931 63932 63933 63934 63935 63936 63937 63938 63939 63940 63941 63942
10 / 8 6,4 96,0
Part no. 63943 63944 63945 63946 63947 63948 63949 63950 63951 63952 63953 63954 63955 63956 63957 63958
16 / 6 8,1 154,0
Part no. 63959 63960 63961 63962 63963 63964 63965 63966 63967 63968 63969 63970 63971 63972 63973 63974
25 / 4 9,6 240,0
Part no. 63975 63976 63977 63978 63979 63980 63981 63982 63983 63984 63985 63986 63987 63988 63989 63990
35 / 2 10,8 336,0
Part no. 63991 63992 63993 63994 63995 63996 63997 63998 63999 64000 64001 64002 64003 64004 64005 64006
50 / 1 13,6 480,0
Part no. 64007 64008 64009 64010 64011 64012 64013 64014 64015 64016 64017 64018 64019 64020 64021 64022
70 / 2/0 15,2 672,0
Part no. 64023 64024 64025 64026 64027 64028 64029 64030 64031 64032 64033 64034 64035 64036 64037 64038
95 / 3/0 16,8 912,0
Part no. 64039 64040 64041 64042 64043 64044 64045 64046 64047 64048 64049 64050 64051 64052 64053 64054
120 / 4/0 19,5 1152,0
Part no. 64055 64056 64057 64058 64059 64060 64061 64062 64063 64064 64065 64066 64067 64068 64069 64070
150 / 300 kcmil 22,2 1440,0

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

489
Cables according to international Approvals / Single Conductors UL/CSA

FIVENORM HAR-UL-CSA-AWM-MTW, PVC single core, UL-Style


10269/UL-Standard 1063, 600 V, 105C

Technical data Cable structure Properties


PVC-single cores acc. to Bare copper fine wire stranded to The materials used in manufacture are
DIN VDE 0285-525-2-31/ DIN VDE 0295 cl.5, BS 6360 cl.5 and cadmium-free and contain no silicone
DIN EN 50525-2-31, UL-Std.1063, IEC 60228 cl.5, acc. to UL-Std.758 and free from substances harmful to
UL-Style 10269 and CSA-TEW and Core insulation of PVC the wetting properties of lacquers
CSA-AWM I/A/B compound type TI3 to Tests
Temperature range DIN VDE 0207-363-3/DIN EN 50363-3 PVC self-extinguishing and flame retardant
H05V2-K / H07V2-K CSA-C 22.2 No. 210 tab.12 class H acc. to VDE 0482-332-1-2,
flexing +5C to +90C and class 43 acc. to UL-Std.1581 DIN EN 60332-1-2/IEC 60332-1 (equivalent
fixed installation -40C to +90C Core identification to DIN VDE 0293 DIN VDE 0472 part 804 test method B),
UL (AWM) -40C to +105C UL VW-1, CSA FT1
UL (MTW) -40C to +90C
CSA (TEW) -40C to +105C Note
Nominal voltage Tinned conductor on request.
up to 1 mm H05V2-K: U0/U 300/500 V up to = 1,0 mm = H05V2-K,
from 1,5 mm H07V2-K: U0/U 450/750 V from 1,5 mm up to 35 mm = H07V2-K.
UL (AWM) 1000 V (ac) Cross-sections up to 35 mm is acc. to
UL (AWM) 1250 V (dc) DIN VDE 0285-525-2-31. Due to this
UL (MTW) 600 V cross-section >35 mm is the type H07V-K
CSA (TEW) 600 V but with an increased heat-resistant
Test voltage PVC-compound TI3.
H05V2-K / H07V2-K 2000 V Type H05V:
Test voltage (Spark Test) approved one-colour mark: black, blue,
AWG 22 = 5 kV brown, grey, orange, pink, red, turquoise,
> AWG 20 = 6 kV violet, white, green and yellow.
Insulation resistance Two-coloured mark in any combination of
min. 20 MOhm x km the above individual colours.
Minimum bending radius Type H07V:
fixed installation for core : approved mark: black, blue, brown, grey,
8 mm: 4x core orange, pink, red, turquoise, violet, white
> 8-12 mm: 5x core and green-yellow.
> 12 mm: 6x core Other marks are available as (H).

Application
Five norms approved connecting jumper wire primarily designed for exportes, used in machine tools. The approbation of HAR, UL-AWM, UL-MTW,
CSA-AWM, CSA-Equipment-wire make possible an economical storekeeping and simplification of parts list.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05V2-K
Cross-sec. Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
mm app. mm weight
/ AWG-no. kg / km
app. RAL 9005 - 5015 8003 3000 1013 7000 4005 1021 3015 6018 - 5010 2003 - -
Part no. 64075 64076 64077 64078 64079 64080 64081 64082 64083 64084 64085 64086 64087 64088 64089 64090
0,5 / 22 2,65 5,2
Part no. 64091 64092 64093 64094 64095 64096 64097 64098 64099 64100 64101 64102 64103 64104 64105 64106
0,75 / 20 2,6 7,2
Part no. 64107 64108 64109 64110 64111 64112 64113 64114 64115 64116 64117 64118 64119 64120 64121 64122
1 / 18 2,8 9,6

Continuation

490
Cables according to international Approvals / Single Conductors UL/CSA

FIVENORM HAR-UL-CSA-AWM-MTW, PVC single core, UL-Style


10269/UL-Standard 1063, 600 V, 105C
H07V2-K
Cross-sec. Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
mm app. mm weight
/ AWG-no. kg / km
app. RAL 9005 - 5015 8003 3000 1013 7000 4005 1021 3015 6018 - 5010 2003 - -
Part no. 64123 64124 64125 64126 64127 64128 64129 64130 64131 64132 64133 64134 64135 64136 64137 64138
1,5 / 16 3,0 14,4
Part no. 64139 64140 64141 64142 64143 64144 64145 64146 64147 64148 64149 64150 64151 64152 64153 64154
2,5 / 14 3,6 24,0
Part no. 64155 64156 64157 64158 64159 64160 64161 64162 64163 64164 64165 64166 64167 64168 64169 64170
4 / 12 4,1 38,0
Part no. 64171 64172 64173 64174 64175 64176 64177 64178 64179 64180 64181 64182 64183 64184 64185 64186
6 / 10 4,8 58,0
Part no. 64187 64188 64189 64190 64191 64192 64193 64194 64195 64196 64197 64198 64199 64200 64201 64202
10 / 8 6,4 96,0
Part no. 64203 64204 64205 64206 64207 64208 64209 64210 64211 64212 64213 64214 64215 64216 64217 64218
16 / 6 8,1 154,0
Part no. 64219 64220 64221 64222 64223 64224 64225 64226 64227 64228 64229 64230 64231 64232 64233 64234
25 / 4 9,6 240,0
Part no. 64235 64236 64237 64238 64239 64240 64241 64242 64243 64244 64245 64246 64247 64248 64249 64250
35 / 2 10,8 336,0
Part no. 64251 64252 64253 64254 64255 64256 64257 64258 64259 64260 64261 64262 64263 64264 64265 64266
50 / 1 13,6 480,0
Part no. 64267 64268 64269 64270 64271 64272 64273 64274 64275 64276 64277 64278 64279 64280 64281 64282
70 / 2/0 15,2 672,0
Part no. 64283 64284 64285 64286 64287 64288 64289 64290 64291 64292 64293 64294 64295 64296 64297 64298
95 / 3/0 16,8 912,0
Part no. 64299 64300 64301 64302 64303 64304 64305 64306 64307 64308 64309 64310 64311 64312 64313 64314
120 / 4/0 19,5 1152,0
Part no. 64315 64316 64317 64318 64319 64320 64321 64322 64323 64324 64325 64326 64327 64328 64329 64330
150 / 300 kcmil 22,2 1440,0

H05V2-K, barrel (with various capacity)


Cross-sec. Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
mm app. mm weight
/ AWG-no. kg / km
app. RAL 9005 - 5015 8003 3000 1013 7000 4005 1021 3015 6018 - 5010 2003 - -
Part no. 65402 65403 65404 65405 65406 65407 65408 65409 65413 65410 65412 65414 65411
0,5 / 22 2,5 5,2
Part no. 65415 65416 65417 65418 65419 65420 65421 65422 65426 65423 65425 65427 65424
0,75 / 20 2,65 7,2
Part no. 65428 65429 65430 65431 65432 65433 65434 65435 65439 65436 65438 65440 65437
1 / 18 2,8 9,6

H07V2-K, barrel (with various capacity)


Cross-sec. Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
mm app. mm weight
/ AWG-no. kg / km
app. RAL 9005 - 5015 8003 3000 1013 7000 4005 1021 3015 6018 - 5010 2003 - -
Part no. 65441 65442 65443 65444 65445 65446 65447 65448 65452 65449 65451 65453 65450
1,5 / 16 3,05 14,4
Part no. 65454 65455 65456 65457 65458 65459 65460 65461 65465 65462 65464 65466 65463
2,5 / 14 3,6 24,0
Part no. 65467 65468 65469 65470 65471 65472 65473 65474 65478 65475 65477 65549 65476
4 / 12 4,1 38,0

H05V2-K two colour


Cross-sec. Outer Cop. BU/WH WH/BU D-BU/WH WH/OG WH/RD BK/OG D-BU/OG RD/WH WH/D-BU YE/BN OG/BU
N
mm app. mm weight
/ AWG-no. kg / km
app. RAL - - - - - - - - - - - - - - - -
Part no. 63402 63403 63404 63405 63406 63482 63332 63352 63372 65386 69625
0,5 / 22 2,5 5,2
Part no. 63407 63408 63409 63410 63411 63483 63333 63353 63373 65387 69626
0,75 / 20 2,65 7,2
Part no. 63412 63413 63414 63415 63416 63484 63334 63354 63374 65388 69627
1 / 18 2,8 9,6

H05V2-K two colour


Cross-sec. Outer Cop. WH/YE OG/D-BU YE/BU BU/OG OG/RD OG/BK OG/WH YE/RD BK/YE
mm app. mm weight
/ AWG-no. kg / km
app. RAL - - - - - - - - - - - - - - - -
Part no. 69827 69828 69829 69830 69831 69832 69833 69834 69835
0,5 / 22 2,5 5,2
Part no. 69836 69837 69838 69839 69840 69841 69842 69843 69844
0,75 / 20 2,65 7,2
Part no. 69845 69846 69847 69848 69849 69850 69851 69852 69853
1 / 18 2,8 9,6

Continuation

491
Cables according to international Approvals / Single Conductors UL/CSA

FIVENORM HAR-UL-CSA-AWM-MTW, PVC single core, UL-Style


10269/UL-Standard 1063, 600 V, 105C
(H)07V2-K two colour
Cross-sec. Outer Cop. BU/WH WH/BU D-BU/WH WH/OG WH/RD BK/OG D-BU/OG RD/WH WH/D-BU YE/BN OG/BU
mm app. mm weight
/ AWG-no. kg / km
app. RAL - - - - - - - - - - - - - - - -
Part no. 63417 63418 63419 63420 63421 63485 63335 63355 63375 65389 69628
1,5 / 16 3,05 14,4
Part no. 63422 63423 63424 63425 63426 63486 63336 63356 63376 65390 69629
2,5 / 14 3,6 24,0
Part no. 63427 63428 63429 63430 63431 63487 63337 63357 63377 65391 69630
4 / 12 4,1 38,0
Part no. 63432 63433 63434 63435 63436 63488 63338 63358 63378 65392 69655
6 / 10 4,8 58,0
Part no. 63437 63438 63439 63440 63441 63489 63339 63359 63379 65393 69656
10 / 8 6,4 96,0
Part no. 63442 63443 63444 63445 63446 63490 63340 63360 63380 65394 69657
16 / 6 8,1 154,0
Part no. 63447 63448 63449 63450 63451 63491 63342 63362 63382 65395 69658
25 / 4 9,6 240,0
Part no. 63452 63453 63454 63455 63456 63492 63343 63363 63383 65396 69659
35 / 2 10,8 336,0
Part no. 63457 63458 63459 63460 63461 63493 63344 63364 63384 65397 69660
50 / 1 13,6 480,0
Part no. 63462 63463 63464 63465 63466 63494 63345 63365 63385 65398 69738
70 / 2/0 15,2 627,0
Part no. 63467 63468 63469 63470 63471 63495 63346 63366 63386 65499 69739
95 / 3/0 16,8 912,0
Part no. 63472 63473 63474 63475 63476 63496 63347 63367 63387 65400 69740
120 / 4/0 19,5 1152,0
Part no. 63477 63478 63479 63480 63481 63497 63348 63368 63388 65401 69741
150 / 300 kcmil 22,2 1440,0

(H)07V2-K two colour


Cross-sec. Outer Cop. WH/YE OG/D-BU YE/BU BU/OG OG/RD OG/BK OG/WH YE/RD BK/YE
mm app. mm weight
/ AWG-no. kg / km
app. RAL - - - - - - - - - - - - - - - -
Part no. 69854 69855 69856 69857 69858 69859 69860 69861 69862
1,5 / 16 3,05 14,4
Part no. 69863 69864 69865 69866 69867 69868 69869 69870 69871
2,5 / 14 3,6 24,0
Part no. 69872 69873 69874 69875 69876 69877 69878 69879 69880
4 / 12 4,1 38,0
Part no. 69881 69882 69883 69884 69885 69886 69887 69888 69889
6 / 10 4,8 58,0
Part no. 69890 69891 69892 69893 69894 69895 69896 69897 69898
10 / 8 6,4 96,0
Part no. 69899 69900 69901 69902 69903 69904 69905 69906 69907
16 / 6 8,1 154,0

H05V2-K two colour, barrel (with various capacity)


Cross-sec. Outer Cop. BU/WH WH/BU D-BU/WH WH/OG WH/RD BK/OG D-BU/OG RD/WH WH/D-BU YE/BN OG/BU
mm app. mm weight
/ AWG-no. kg / km
app. RAL - - - - - - - - - - - - - - - -
Part no. 65479 65480 65481 65482 65483 65484 65485 65486 65487 65488 65489
0,5 / 22 2,5 5,2
Part no. 65490 65491 65492 65493 65494 65495 65496 65497 65498 65502 65503
0,75 / 20 2,65 7,2
Part no. 65504 65505 65506 65507 65508 65509 65510 65511 65512 65514 65515
1 / 18 2,8 9,6

(H)07V2-K two colour, barrel (with various capacity)


Cross-sec. Outer Cop. BU/WH WH/BU D-BU/WH WH/OG WH/RD BK/OG D-BU/OG RD/WH WH/D-BU YE/BN OG/BU
mm app. mm weight
/ AWG-no. kg / km
app. RAL - - - - - - - - - - - - - - - -
Part no. 65516 65517 65518 65519 65520 65521 65522 65523 65524 65525 65526
1,5 / 16 3,05 14,4
Part no. 65527 65528 65529 65530 65531 65532 65533 65534 65535 65536 65537
2,5 / 14 3,6 24,0
Part no. 65538 65539 65540 65541 65542 65543 65544 65545 65546 65547 65548
4 / 12 4,1 38,0

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

492
Cables according to international Approvals / Single Conductors UL

THHN/THWN 90C, 600 V, UL listed, PVC + nylon single core

Technical data Cable structure Properties


PVC + Nylon insulated single cores as per Bare copper conductor, AWG-sizes as per Resistant against
UL-Styles and NEC standard given table below and ASTM B-3 and ASTM Oils
Temperature range as per Styles B-8 Gasoline
THHN: 90C dry - NEC standard Core insulation of PVC Water
THWN: 75C wet - NEC standard and Nylon-outer-sheath Acids
AWM: UL-Styles 1316 to 1321 Cores colour coded, colour identification Ozone
105C dry see below Lyes
80C in oil Surface of sheath printed with markings: Sunlight
AWM: UL-Styles 1452, 1453 14 to 1000 MCM THHN (stranded) - (size) Abrasion
90C dry AWG Type MTW OR THHN OR THWN 600 V
80C in oil 1000 V OR GASOLINE AND OIL RESTSTANT II (UL) Note
MTW: UL-Styles 1408 to 1414 OR AWM W-51554 1 kcmil = 1000 circ mils = 0,5067 mm.
90C dry 14 to 10 AWG THHN (solid) - (size) Please complete the part number for
80C in oil 600 V AWG TYPE THHN OR THWN 600 V OR these cables by adding the suffix for
Nominal voltage 600 V GASOLINE AND OIL RESISTANT II (UL) OR the colour required as per the list:
Minimum bending radius AWM 0 = green
8x core 1 = black
Test voltage (Spark test) 2 = blue
AWG 14 to AWG 10 = 7,5 kV 3 = brown
AWG 8 to AWG 2/0 = 10 kV 4 = red
AWG 3/0 to AWG 4/0 = 12,5 kV 5 = white
kcmil 250 to kcmil 500 = 15 kV 6 = grey
kcmil 600 to kcmil 1000 = 17,5 kV 7 = yellow
8 = orange
9 = pink

Application
As flexible connecting cable in machines, switch and distribution cabinets, cable assemblies and for fixed indoor installation, in tubes and in cable
conduits.
AWM = Appliance Wiring Material
For internal wrings for electrical equipment and control apparatus e. g. radio and televisions, electronic assembly component. N
MTW = Machine Tool Wire
For the electronical installation of machine tools and the relative control. THW = Thermoplastic PVC-insulated building wire, Heat resistant 75C, for
Wet and dry locations, flame retardant. THHN = Thermoplastic PVC-insulated building wire, Nylon sheathed, 90C 600 V, for dry and damp locations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cross- AWG-No. Cond. make-up Outer Cop. Weight


section mm n x wire app. mm weight app. kg / km
kg / km
6320x 2,08 14 19 x 0,38 3,0 20,7 25,0
6321x 3,32 12 19 x 0,48 3,4 33,0 37,0
6322x 5,26 10 19 x 0,6 4,3 51,6 60,0
6323x 8,35 8 19 x 0,75 5,5 80,6 95,0
6324x 13,39 6 19 x 0,96 6,6 125,0 143,0
6325x 21,14 4 19 x 1,19 8,4 201,0 229,0
6326x 26,65 3 19 x 1,336 9,1 253,0 282,0
6327x 33,61 2 19 x 1,5 10,0 317,0 349,0
6328x 42,38 1 19 x 1,686 11,4 399,0 449,0
6329x 53,47 1/0 19 x 1,89 12,4 500,0 557,0
6330x 67,4 2/0 19 x 2,126 13,7 631,0 691,0
6331x 84,97 3/0 19 x 2,387 15,0 792,0 861,0
6332x 107,17 4/0 19 x 2,68 16,5 996,0 1069,0

Part no. Cross- AWG-No. Cond. make-up Outer Cop. Weight


section mm n x wire app. mm weight app. kg / km
kg / km
63331 127 250 kcmil 37 x 2,088 18,29 1178,0 1277,0
63341 152 300 kcmil 37 x 2,286 19,56 1410,0 1515,0
63351 178 350 kcmil 37 x 2,47 21,08 1645,0 1753,0
63361 203 400 kcmil 37 x 2,7 22,35 1902,0 1998,0
63371 254 500 kcmil 37 x 2,95 24,13 2345,0 2466,0
63381 304 600 kcmil 61 x 2,52 26,75 2920,0 3000,0
63391 380 750 kcmil 61 x 2,82 29,36 3658,0 3713,0
63401 507 1000 kcmil 61 x 3,25 33,27 4858,0 4796,0

Dimensions and specifications may be changed without prior notice. (RN06)

493
Cables according to international Approvals / Single Conductors

PVC single cores according to CEI-20-22 II

Technical data Cable structure Properties


PVC-Single Cores as per Italian standard Bare fine wire stranded copper conductor Low smoke
CEI 20-22 II to CEI 20-29 cl.5 Resistant to
Temperature range Core insulation of PVC Oil
flexing -5C to +80C R 2 up to CEI 20 II, cap. VI cl. 3 Solvents
fixed installation -30C to +80C Acids
Nominal voltage Lyes
up to 0,35 mm U0/U 300/300 V The materials used in manufacture are
0,5 and 0,75 mm U0/U 300/500 V cadmium-free and contain no silicone
from 1 mm U0/U 450/750 V and free from substances harmful to
Test voltage 2500 V the wetting properties of lacquers
Minimum bending radius Tests
fixed installation for core : PVC self-extinguishing and flame retardant
8 mm: 4x core acc. to DIN VDE 0482-332-1-2,
> 8-12 mm: 5x core DIN EN 60332-1-2, IEC 60332-1 (equivalent
> 12 mm: 6x core DIN VDE 0472 part 804 test method B)

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
As hook up wire, control cabinet building, in cable assembly manufacturing as well as in electronic applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Cross- Outer Cop. Weight BK GN-YE BU BN RD WH D-BU o.col.


section app. mm weight app. kg / km
mm kg / km
app. RAL 9005 - 5015 8003 3000 1013 5010 -
Part no. 29600 29601 29602 29603 29604 29605 29606 29607
0,35 1,5 2,5 3,6 - - - - - - - -
Part no. 29608 29609 29610 29611 29612 29613 29614 29615
0,5 2,6 4,8 6,0 20 20 20 20 20 20 20 20
Part no. 29616 29617 29618 29619 29620 29621 29622 29623
0,75 2,8 7,2 10,0 18 18 18 18 18 18 18 18
Part no. 29624 29625 29626 29627 29628 29629 29630 29631
1 3,2 9,6 16,0 17 17 17 17 17 17 17 17
Part no. 29632 29633 29634 29635 29636 29637 29638 29639
1,5 3,5 14,4 21,0 16 16 16 16 16 16 16 16
Part no. 29640 29641 29642 29643 29644 29645 29646 29647
2,5 4,2 24,0 32,0 14 14 14 14 14 14 14 14
Part no. 29648 29649 29650 29651 29652 29653 29654 29655
4 4,6 38,0 48,0 12 12 12 12 12 12 12 12
Part no. 29656 29657 29658 29659 29660 29661 29662 29663
6 6,3 58,0 69,0 10 10 10 10 10 10 10 10
Part no. 29664 29665 29666 29667 29668 29669 29670 29671
10 7,6 96,0 117,0 8 8 8 8 8 8 8 8
Part no. 29672 29673 29674 29675 29676 29677 29678 29679
16 8,8 154,0 180,0 6 6 6 6 6 6 6 6
Part no. 29680 29681 29682 29683 29684 29685 29686 29687
25 11,0 240,0 266,0 4 4 4 4 4 4 4 4
Part no. 29688 29689 29690 29691 29692 29693 29694 29695
35 12,5 336,0 366,0 2 2 2 2 2 2 2 2
Part no. 29696 29697 29698 29699 29700 29701 29702 29703
50 14,5 480,0 515,0 1 1 1 1 1 1 1 1
Part no. 29704 29705 29706 29707 29708 29709 29710 29711
70 16,5 672,0 741,0 2/0 2/0 2/0 2/0 2/0 2/0 2/0 2/0
Part no. 29712 29713 29714 29715 29716 29717 29718 29719
95 18,5 912,0 950,0 3/0 3/0 3/0 3/0 3/0 3/0 3/0 3/0
Part no. 29720 29721 29722 29723 29724 29725 29726 29727
120 21,0 1152,0 1230,0 4/0 4/0 4/0 4/0 4/0 4/0 4/0 4/0
Part no. 29728 29729 29730 29731 29732 29733 29734 29735
150 23,0 1440,0 1500,0 300 kcmil 300 kcmil 300 kcmil 300 kcmil 300 kcmil 300 kcmil 300 kcmil 300 kcmil

Dimensions and specifications may be changed without prior notice. (RN06)

494
Cables according to international Approvals / Single Conductors UL/CSA

HELUTHERM 145 300 V, flexible single core, cross-linked,


halogen-free

Technical data Cable structure Properties


Halogen-free single cores with increased Tinned Cu wires, acc. to AWG-sizes Halogen-free
heat resistance acc. to Conductor make-up: Lower propagation of fire
UL-Style 3376 (AWG 24 - AWG 16) AWG 24 to AWG 14 = 19-wires Low development of smoke and fumes
UL-Style 3578 (AWG 14 - AWG 10) AWG 12 = 65-wires Good abrasion and notch resistance
CSA C22.2 No. 210 AWG 10 = 105-wires Good resistance to oils and weathering
Temperature range Core insulation of polyolefin-copolymer, Resistant to UV radiation and ozone
flexing -35C to +120C cross-linked Resistant to soldering temperatures
fixed installation -55C to +145C Core colours see table below Thermal class B
UL/CSA Tests These single-core cables are resistant to
flexing -35C to +105C Flame test acc. to melting, even when in contact with a
fixed installation - 55C to +105C DIN VDE 0482-332-3, BS 4066 part 3, soldering iron at temperatures of between
Nominal voltage 300 V DIN EN 60332-3, IEC 60332-3 (previously 300C and 380C, because of the
Test voltage 2000 V DIN VDE 0472 part 804 test method C) electron-beam cross-linking for the
Minimum bending radius Corrosiveness of combustion gases insulation material
flexing 12,5x core acc. to DIN VDE 0482 part 267, Due to the high temperature profile the
fixed installation 4x core DIN EN 50267-2-2, IEC 60754-2 cross-section of conductor can under
Caloric load values (equivalent DIN VDE 0472 part 813) certain circumstances be reduced, hereby
see Technical Informations Halogen-free acc. to enabling a saving in space requirement
Power ratings table DIN VDE 0482 part 267, and weight
see Technical Informations DIN EN 50267-2-1, IEC 60754-1 The materials used in manufacture are
Approval (equivalent DIN VDE 0472 part 815) cadmium-free and contain no silicone
Germanischer Lloyd Smoke density acc. to DIN VDE 0482 and free from substances harmful to
part 1034-1+2, DIN EN 61034-1+2, the wetting properties of lacquers
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Application
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systems
and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation ducts, as well as for
traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks. These halogen-free single core N
cables are characterised by their amazingly hight long-time resistance to temperature and feature among the leading halogen-free. Flame resistant
products in the world.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

AWG-No. Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE PK GN OG BEIGE 2-col.


app. mm weight app.
kg / km kg / km
Part no. 61817 61816 61818 61819 61820 61821 61822 61823 61824 59339 61826 61825 61828 61829
24 1,5 2,3 4,0
Part no. 61831 61830 61832 61833 61834 61835 61836 61837 61838 61841 61840 61839 61842 61843
22 1,6 3,2 6,0
Part no. 61845 61844 61846 61847 61848 61849 61850 61851 61852 61855 61854 61853 61856 61857
20 1,9 5,0 9,0
Part no. 61859 61858 61860 61861 61862 61863 61864 61865 61866 61869 61868 61867 61870 61871
18 2,1 7,9 12,0
Part no. 61873 61872 61874 61875 61876 61877 61878 61879 61880 61883 61882 61881 61884 61885
16 2,4 12,6 16,0
Part no. 61887 61886 61888 61889 61890 61891 61892 61893 61894 61897 61896 61895 61898 61899
14 3,5 20,7 27,0
Part no. 61901 61900 61902 61903 61904 61905 61906 61907 61908 61911 61910 61909 61912 61913
12 4,2 33,0 36,0
Part no. 61915 61914 61916 61917 61918 61919 61920 61921 61922 61925 61924 61923 61926 61927
10 4,8 51,6 58,0

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

495
Cables according to international Approvals / Single Conductors UL/CSA

HELUTHERM 145 600 V, flexible single core, cross-linked,


halogen-free

Technical data Cable structure Properties


Halogen-free single cores with increased Tinned Cu wires, acc. to Halogen-free
heat resistance acc. to UL Style 3578 DIN VDE 0295 cl.5, BS 6360 cl.5 and Lower propagation of fire
CSA C22.2 No. 210 IEC 60228 cl.5 Low development of smoke and fumes
Temperature range Core insulation of cross-linked Good abrasion and notch resistance
flexing -35C to +120C polyolefin-copolymer Good resistance to oils and weathering
fixed installation -55C to +145C Core colours see table below Resistant to UV radiation and ozone
UL/CSA Tests Resistant to soldering temperatures
flexing -35C to +105C Flame test acc. to DIN VDE 0482-332-3-22, Resistant to melting, even when in contact
fixed installation -55C to +105C BS 4066 part 3, DIN EN 60332-3-22, with a soldering iron at temperatures of
Nominal voltage 600 V IEC 60332-3-22 (previously DIN VDE 0472 between 300C and 380C, because of the
Test voltage 3000 V part 804 test method C) cross-linking for the insulation material
Minimum bending radius Corrosiveness of combustion gases Due to the high temperature profile the
flexing 12,5x core acc. to DIN VDE 0482 part 267, cross-section of conductor can under
fixed installation 4x core DIN EN 50267-2-2, IEC 60754-2 certain circumstances be reduced, hereby
Caloric load values (equivalent DIN VDE 0472 part 813) enabling a saving in space requirement
see Technical Informations Halogen-free acc. to and weight
Power ratings table DIN VDE 0482 part 267, The materials used in manufacture are
see Technical Informations DIN EN 50267-2-1, IEC 60754-1 cadmium-free and contain no silicone
Approval (equivalent DIN VDE 0472 part 815) and free from substances harmful to
Germanischer Lloyd Smoke density acc. to DIN VDE 0482 the wetting properties of lacquers
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Application
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systems
and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation ducts, as well as for
traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks. These halogen-free single core
cables are characterised by their amazingly high long-time resistance to temperature and feature among the leading halogen-free, flame resistant
products in the world.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE PK GN OG BEIGE 2-col.


sec. app. mm weight app.
mm kg / km kg / km
Part no. 59473 59472 59474 59475 59476 59477 59478 59479 59480 59483 59482 59481 59484 59485
0,25 2,3 2,4 7,0
Part no. 59487 59486 59488 59489 59490 59491 59492 59493 59494 59497 59496 59495 59498 59499
0,5 2,6 4,8 11,0
Part no. 59501 59500 59502 59503 59504 59505 59506 59507 59508 59511 59510 59509 59512 59513
0,75 2,8 7,2 14,0
Part no. 59515 59514 59516 59517 59518 59519 59520 59521 59522 59525 59524 59523 59526 59527
1 2,9 9,6 17,0
Part no. 59529 59528 59530 59531 59532 59533 59534 59535 59536 59539 59538 59537 59540 59541
1,5 3,2 14,4 22,0
Part no. 59543 59542 59544 59545 59546 59547 59548 59549 59550 59553 59552 59551 59554 59555
2,5 3,7 24,0 33,0
Part no. 59557 59556 59558 59559 59560 59561 59562 59563 59564 59567 59566 59565 59568 59569
4 4,2 38,4 53,0
Part no. 59571 59570 59572 59573 59574 59575 59576 59577 59578 59581 59580 59579 59582 59583
6 5,0 57,6 78,0
Part no. 59585 59584 59586 59587 59588 59589 59590 59591 59592 59595 59594 59593 59596 59597
10 6,4 96,0 136,0
Part no. 59599 59598 59600 59601 59602 59603 59604 59605 59606 59609 59608 59607 59610 59611
16 8,5 154,0 203,0
Part no. 59613 59612 59614 59615 59616 59617 59618 59619 59620 59623 59622 59621 59624 59625
25 10,4 240,0 300,0
Part no. 59627 59626 59628 59629 59630 59631 59632 59633 59634 59637 59636 59635 59638 59639
35 11,5 336,0 405,0
Part no. 59641 59640 59642 59643 59644 59645 59646 59647 59648 59651 59650 59649 59652 59653
50 14,4 480,0 580,0

Dimensions and specifications may be changed without prior notice. (RN06)

496
Cables according to international Approvals / Single Conductors UL

UL-Style 3135 silicone single core, 600 V / 200C, halogen-free

Technical data Cable structure Properties


Silicon single cores acc. to Tinned copper conductors Halogen-free
UL-Std.758 Style 3135 Stranded see table below acc. to VDE 0482 part 267/
Temperature range Core insulation of Silicon DIN EN 50267-2-1/IEC 60754-1 (equivalent
-60C to +200C Core colours see below DIN VDE 0472 part 815)
Nominal voltage 600 V Resistant to
Test voltage 2000 V High molecular oils
Breakdown voltage min. 5000 V fats from vegetables and animals
Minimum bending radius alcohols
15x core plasticizers and clophenes
diluted acids
lyes and salt dissolution
oxidation substances
tropical influences and weather
lake water
oxygen
ozone

Note
Additional sizes on request.

Application
UL-approved single cores for use in high, temperature areas. They are used mainly in the steel producing industries, in aviation industries as well as
in ship building, cement, glas and ceramic factories
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

AWG-No. Conductor Outer Cop. Weight BK BU BN RD WH GY VT GN


construction app. mm weight app. kg / km

Part no.
24 1 x 0,5 2,1
kg / km

1,9 6,3
47021
o. r.
47022
o. r.
47023
o. r.
47024
o. r.
47025
o. r.
47026
o. r.
47027
o. r.
47076
o. r.
N
Part no. 47028 47029 47030 47031 47032 47033 47034 47071
22 3 x 0,4 2,4 3,6 9,2 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
Part no. 47035 47036 47037 47038 47039 47040 47041 47072
20 5 x 0,4 2,6 6,0 12,3 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
Part no. 47042 47043 47044 47045 47046 47047 47048 47073
18 7 x 0,4 2,8 8,6 15,5 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
Part no. 47049 47050 47051 47052 47053 47054 47055 47074
16 11 x 0,4 3,0 13,3 21,0 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
Part no. 47056 47057 47058 47059 47060 47061 47062 47075
14 17 x 0,4 3,4 20,5 29,7 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
Part no. 47063 47064 47065 47066 47067 47068 47069 47070
12 27 x 0,4 3,8 32,6 43,2 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

497
Cables according to international Approvals / Single Conductors UL/CSA

Single 600-J/-O special single core cable, 600 V, meter marking

Technical data Cable structure Properties


Special PVC single core acc. to Bare copper, fine wire conductors to Chemical Resistance - see table Technical
UL-Style 10107 and CSA AWM I/II A/B, DIN VDE 0295 cl.5, BS 6360 cl.5 and informations
adapted to DIN VDE 0285-525-2-31/ IEC 60228 cl.5 Tests
DIN EN 50525-2-31, Core insulation of special PVC PVC self-extinguishing and flame retardant
DIN VDE 0285-525-2-51/ compound type TM2 to acc. to DIN VDE 0482-332-1-2,
DIN EN 50525-2-51, acc. to UL-Std.758 DIN VDE 0207-363-3/ DIN EN 50363-3 DIN EN 60332-1-2, IEC 60332-1 (equivalent
Temperature range and class 43 acc. to UL-Std.1581 DIN VDE 0472 part 804 test method B),
flexing -5C bis +90C colour black or green-yellow UL VW-1, CSA FT1
fixed installation -40C bis +90C Outer sheath of special PVC UV-resistant
Permissible operating temperature compound type TM2 to
max. +90C at conductor DIN VDE 0207-363-4-1/ DIN EN 50363-4-1 Note
Nominal voltage and class 43 acc. to UL-Std.1581 G = with green-yellow conductor
VDE U0/U 600/1000 V Sheath colour black (RAL 9005) x = without green-yellow conductor
UL/CSA 600 V with meter marking AWG sizes are approximate equivalent
Test voltage 4000 V values. The actual cross-section is in mm.
Breakdown voltage min. 8000 V screened analogue type:
Insulation resistance Single 600-CY -J/-O, confer page 499
min. 20 MOhm x km also as 1000 V Style 10678 deliverable
Minimum bending radius
flexing 7,5x cable
fixed installation 4x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
PVC Single cores suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements
in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial- or as underwater cable. These two norms
approved single cores designed for exportorientated machinery manufacturer for machine tools, conveyor belts and production lines.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Core Outer Cop. Weight Part no. No.cores x AWG-No. Core Outer Cop. Weight
cross-sec. colour app. weight app. cross-sec. colour app. weight app.
mm mm kg / km kg / km mm mm kg / km kg / km
10881 1G6 10 green-yellow 7,8 58,0 118,0 10893 1 G 70 2/0 green-yellow 17,9 672,0 910,0
10882 1x6 10 black 7,8 58,0 118,0 10894 1 x 70 2/0 black 17,9 672,0 910,0
10883 1 G 10 8 green-yellow 9,0 96,0 180,0 10895 1 G 95 3/0 green-yellow 19,5 912,0 1195,0
10884 1 x 10 8 black 9,0 96,0 180,0 10896 1 x 95 3/0 black 19,5 912,0 1195,0
10885 1 G 16 6 green-yellow 10,0 154,0 250,0 10897 1 G 120 4/0 green-yellow 22,3 1152,0 1545,0
10886 1 x 16 6 black 10,0 154,0 250,0 10898 1 x 120 4/0 black 22,3 1152,0 1545,0
10887 1 G 25 4 green-yellow 11,5 240,0 370,0 10899 1 G 150 250 kcmil green-yellow 25,0 1440,0 1750,0
10888 1 x 25 4 black 11,5 240,0 370,0 10900 1 x 150 250 kcmil black 25,0 1440,0 1750,0
10889 1 G 35 2 green-yellow 13,0 336,0 490,0 10901 1 G 185 350 kcmil green-yellow 28,6 1776,0 2320,0
10890 1 x 35 2 black 13,0 336,0 490,0 10902 1 x 185 350 kcmil black 28,6 1776,0 2320,0
10891 1 G 50 1 green-yellow 15,6 480,0 665,0 10903 1 G 240 450 kcmil green-yellow 31,4 2304,0 2960,0
10892 1 x 50 1 black 15,6 480,0 665,0 10904 1 x 240 450 kcmil black 31,4 2304,0 2960,0

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

498
Cables according to international Approvals / Single Conductors UL/CSA

Single 600-CY -J/-O special single core cable, 600 V, Cu-screened,


EMC-preferred type, meter marking

Technical data Cable structure Properties


Special PVC single cores acc. to Bare copper, fine wire conductors, to Chemical Resistance - see table Technical
UL-Style 10107 and CSA AWM I/II A/B, DIN VDE 0295 cl.5, BS 6360 cl.5 and Informations
adapted to DIN VDE 0285-525-2-31/ IEC 60228 cl.5 The materials used in manufacture are
DIN EN 50525-2-31, Core isulation of special PVC cadmium-free and contain no silicone
DIN VDE 0285-525-2-51/ compound type TI2 to and free from substances harmful to
DIN EN 50525-2-51, acc. to UL-Std.758 DIN VDE 0207-363-3 / DIN EN 50363-3 the wetting properties of lacquers
Temperature range and class 43 acc. to UL-Std.1581 Tests
flexing -5C bis +90C colour black or green-yellow PVC self-extinguishing and flame retardant
fixed installation -40C bis +90C Tinned copper braided screening, acc. to DIN VDE 0482-332-1-2,
Permissible operating temperature coverage approx. 85% DIN EN 60332-1-2, IEC 60332-1 (equivalent
max. +90C at conductor Outer sheath special PVC DIN VDE 0472 part 804
Nominal voltage compound type TM2 to test method B), UL VW-1, CSA FT1
VDE U0/U 600/1000 V DIN VDE 0207-363-4-1 / UV-resistant
UL/CSA 600 V DIN EN 50363-4-1
Test voltage 4000 V and class 43 acc. to UL-Std.1581 Note
Breakdown voltage min. 8000 V Sheath colour black (RAL 9005) G = with green-yellow conductor
Insulation resistance with meter marking x = without green-yellow conductor
min. 20 MOhm x km AWG sizes are approximate equivalent
Minimum bending radius values. The actual cross-section is in mm.
flexing 7,5x cable unscreened analogue type:
fixed installation 4x cable Single 600-J/-O, confer page 498
Coupling resistance also as 1000 V Style 10678 deliverable
max. 250 Ohm/km
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
PVC single cores suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements
in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial-or as underwater cable. These two norms
approved single cores designed for exportorientated machinery manufacturer for machine tools, conveyor belts and production lines. These screened N
cables are particulary suitable for the interference-free transmission in instrumentation and control engineering applications (electromagnetic
compatibillity).
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Core Outer Cop. Weight Part no. No.cores x AWG-No. Core Outer Cop. Weight
cross-sec. colour app. weight app. cross-sec. colour app. weight app.
mm mm kg / km kg / km mm mm kg / km kg / km
10910 1G6 10 green-yellow 7,6 72,0 140,0 10922 1 G 70 2/0 green-yellow 17,4 780,0 1090,0
10911 1x6 10 black 7,6 72,0 140,0 10923 1 x 70 2/0 black 17,4 780,0 1090,0
10912 1 G 10 8 green-yellow 9,4 130,0 230,0 10924 1 G 95 3/0 green-yellow 20,1 1030,0 1395,0
10913 1 x 10 8 black 9,4 130,0 230,0 10925 1 x 95 3/0 black 20,1 1030,0 1395,0
10914 1 G 16 6 green-yellow 10,4 190,0 300,0 10926 1 G 120 4/0 green-yellow 23,0 1285,0 1770,0
10915 1 x 16 6 black 10,4 190,0 300,0 10927 1 x 120 4/0 black 23,0 1285,0 1770,0
10916 1 G 25 4 green-yellow 12,0 260,0 420,0 10928 1 G 150 250 kcmil green-yellow 26,1 1570,0 1930,0
10917 1 x 25 4 black 12,0 260,0 420,0 10929 1 x 150 250 kcmil black 26,1 1570,0 1930,0
10918 1 G 35 2 green-yellow 14,4 405,0 615,0 10930 1 G 185 350 kcmil green-yellow 29,3 1940,0 2635,0
10919 1 x 35 2 black 14,4 405,0 615,0 10931 1 x 185 350 kcmil black 29,3 1940,0 2635,0
10920 1 G 50 1 green-yellow 16,4 560,0 825,0 10932 1 G 240 450 kcmil green-yellow 32,2 2530,0 3380,0
10921 1 x 50 1 black 16,4 560,0 825,0 10933 1 x 240 450 kcmil black 32,2 2530,0 3380,0

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

499
Cables according to international Approvals / Single Conductors UL/CSA

TOPFLEX 302 / 302-UL very high flexible PVC single core double
insulated 0,6/1kV

Technical data Cable structure Properties


TOPFLEX 302 Bare copper, extra fine wire conductor to Sheath UV-resistant
Special PVC single-core cable with double DIN VDE 0295 cl.6 and IEC 60228 cl.6 PVC self-extinguishing and flame retardant
insulation flexible at low temperatures PVC insulation flexible at low temperatures, acc. to DIN VDE 0482-332-1-2,
Temperature range natural colour DIN EN 60332-1-2, IEC 60332-1 (equivalent
flexing -15C to +80C PVC sheath compound TM2 flexible at low DIN VDE 0472 part 804 test method B)
fixed installation -40C to +80C temperatures Chemical resistance see table Technical
Nominal voltage Sheath colour black Information
U0/U 600/1000 V The cable is permissible for overvoltage
A.C. test voltage, 50 Hz category II
3000 V
Insulation resistance
min. 20 MOhm x km
Minimum bending radius
for flexible installation
5x cable
TOPFLEX 302-UL
Technical data as above, but
with additional UL Approval Style 10107
Nominal voltage
UL 600 V

Application
These cables are specially designed for use as connecting cables on sliding contacts for current collectors, and also for use in energy supply chains,
automatic handling devices, robots, machine tools, machining and processing equipment, and nearly any area requiring flexible used and free motion.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX 302 without UL-approval TOPFLEX 302 with UL-approval
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
72946 1 x 1,5 16 4,0 14,4 25,0 700231 1 x 1,5 16 5,2 14,4 25,0
73924 1 x 2,5 14 4,5 24,0 42,0 700232 1 x 2,5 14 6,4 24,0 42,0
72950 1x4 12 5,6 38,4 58,0 700233 1x4 12 7,0 38,4 58,0
72945 1x6 10 6,1 57,6 85,0 700234 1x6 10 7,5 57,6 85,0
75450 1 x 10 8 8,0 96,0 130,0 701351 1 x 10 8 9,1 96,0 130,0
72947 1 x 16 6 9,8 153,6 190,0 700114 1 x 16 6 10,8 153,6 190,0
75451 1 x 25 4 11,8 240,0 280,0 701352 1 x 25 4 13,1 240,0 280,0
75452 1 x 35 2 12,9 336,0 400,0 701353 1 x 35 2 14,1 336,0 400,0
75453 1 x 50 1 14,6 480,0 520,0 701354 1 x 50 1 15,8 480,0 520,0
72944 1 x 70 2/0 17,5 672,0 720,0 700235 1 x 70 2/0 19,0 672,0 720,0
75454 1 x 95 3/0 20,2 912,0 1050,0 701355 1 x 95 3/0 21,5 912,0 1050,0
75455 1 x 120 4/0 21,6 1152,0 1220,0 701356 1 x 120 4/0 23,2 1152,0 1220,0
75456 1 x 150 300 kcmil 23,5 1440,0 1500,0 701357 1 x 150 300 kcmil 25,2 1440,0 1500,0
75457 1 x 185 350 kcmil 25,7 1776,0 1940,0 701358 1 x 185 350 kcmil 27,0 1776,0 1940,0
75458 1 x 240 500 kcmil 29,5 2304,0 2675,0 701359 1 x 240 500 kcmil 31,5 2304,0 2675,0

Dimensions and specifications may be changed without prior notice.

500
Cables according to international Approvals / Single Conductors UL/CSA

Single 602-RC -J/O special single core cable for drag chains,
90C, 600 V, meter marking

Technical data Cable structure Properties


Special PVC single core acc. to Bare copper, extra fine wire conductors, Chemical Resistance - see table Technical
UL-Style 10107 and CSA AWM I/II AB, to DIN VDE 0295 cl.6, col. 4, BS 6360 cl.6 Informations
core acc. to DIN VDE 0285-525-2-31/ and IEC 60228 cl.6, however by 185 mm Resistant to mineral oils, synthetic oils and
DIN EN 50525-2-31 up to 300 mm with reduced single wire-, lubricating coolants.
(except 300 mm) max. 0,30 mm The materials used in manufacture are
Temperature range Core insulation of special PVC cadmium-free and contain no silicone
flexing -5C to +90C compound type TI3 to and free from substances harmful to
fixed installation -40C to +90C DIN VDE 0207-363-3 / DIN EN 50363-3 the wetting properties of lacquers
Permissible operating temperature and class 43, 90C acc. to UL-Std.1581 Tests
max. +90C at conductor colour black or green-yellow PVC self-extinguishing and flame retardant
Nominal voltage Outer sheath special PVC acc. to DIN VDE 0482-332-1-2,
VDE U0/U 600/1000 V compound type YM5 to DIN EN 60332-1-2, IEC 60332-1 (equivalent
UL/CSA 600 V DIN VDE 0207 part 5 and class 43, 90C DIN VDE 0472 part 804 test method B)
Test voltage 4000 V acc. to UL-Std.1581 UL VW-1, CSA FT1
Breakdown voltage min. 8000 V Sheath colour black (RAL 9005) Acc.to UL-Style 10107/ UL-Std.1581,
Insulation resistance with meter marking CSA C22.2 No 210
min. 20 MOhm x km
Minimum bending radius Note
flexing 7,5x cable G = with green-yellow conductor
fixed installation 3x cable x = without green-yellow conductor (OZ)
Radiation resistance 300 mm in adaption
up to 80x106 cJ/kg (up to 80 Mrad) AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
Single 602-RC-CY-J/O, confer page 502

Application
High flexible special single core cable for drag chains are used for flexible use for medium mechanical stresses with free movement without tensile
stress or forced movements in dry, moist and wet rooms. These two-norm cables primarily designed for exportorientated machinery manufacturer
for flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts. For applications which go beyond
N
standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for
our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Core Outer Cop. Weight Part no. No.cores x AWG-No. Core Outer Cop. Weight
cross-sec. colour app. weight app. cross-sec. colour app. weight app.
mm mm kg / km kg / km mm mm kg / km kg / km
69601 1 G 10 8 green-yellow 9,4 96,0 180,0 69613 1 G 95 3/0 green-yellow 20,5 912,0 1195,0
69602 1 x 10 8 black 9,4 96,0 180,0 69614 1 x 95 3/0 black 20,5 912,0 1195,0
69603 1 G 16 6 green-yellow 10,5 154,0 250,0 69615 1 G 120 4/0 green-yellow 23,0 1152,0 1545,0
69604 1 x 16 6 black 10,5 154,0 250,0 69616 1 x 120 4/0 black 23,0 1152,0 1545,0
69605 1 G 25 4 green-yellow 11,6 240,0 370,0 69617 1 G 150 250 kcmil green-yellow 25,2 1440,0 1750,0
69606 1 x 25 4 black 11,6 240,0 370,0 69618 1 x 150 250 kcmil black 25,2 1440,0 1750,0
69607 1 G 35 2 green-yellow 14,5 336,0 490,0 69619 1 G 185 350 kcmil green-yellow 29,0 1776,0 2320,0
69608 1 x 35 2 black 14,5 336,0 490,0 69620 1 x 185 350 kcmil black 29,0 1776,0 2320,0
69609 1 G 50 1 green-yellow 16,6 480,0 665,0 69621 1 G 240 450 kcmil green-yellow 32,5 2304,0 2960,0
69610 1 x 50 1 black 16,6 480,0 665,0 69622 1 x 240 450 kcmil black 32,5 2304,0 2960,0
69611 1 G 70 2/0 green-yellow 18,4 672,0 910,0 69623 1 G 300 550 kcmil green-yellow 35,4 2880,0 3550,0
69612 1 x 70 2/0 black 18,4 672,0 910,0 69624 1 x 300 550 kcmil black 35,4 2880,0 3550,0

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

501
Cables according to international Approvals / Single Conductors UL/CSA

Single 602-RC -CY -J/O special single core cable


for drag chains, 90C, 600 V, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special PVC single core cable acc. to Bare copper, extra fine wire conductors, to Chemical Resistance - see table Technical
UL-Style 10107 and CSA AWM I/II A/B, DIN VDE 0295 cl.6, col. 4, BS 6360 cl.6 Informations
core acc. to DIN VDE 0285-525-2-31/ and IEC 60228 cl.6, however by 185 mm Resistant to mineral oils, synthetic oils and
DIN EN 50525-2-31 (except 300 mm) up to 300 mm with reduced single wire-, lubricating coolants.
Temperature range max. 0,30 mm The materials used in manufacture are
flexing -5C to +90C Core insulation of special PVC cadmium-free and contain no silicone
fixed installation -40C to +90C compound type TI3 to and free from substances harmful to
Permissible operating temperature DIN VDE 0207-363-3 / DIN EN 50363-3 the wetting properties of lacquers
max. +90C at conductor and class 43, 90C acc. to UL-Std.1581 Tests
Nominal voltage colour black or green-yellow PVC self-extinguishing and flame retardant
VDE U0/U 600/1000 V Tinned copper braided screening, acc. to DIN VDE 0482-332-1-2,
UL/CSA 600 V coverage approx. 80% DIN EN 60332-1-2, IEC 60332-1 (equivalent
Test voltage 4000 V Outer sheath special PVC DIN VDE 0472 part 804 test method B),
Breakdown voltage min. 8000 V compound type YM5 to UL VW-1, CSA FT1
Insulation resistance DIN VDE 0207 part 5 and class 43, 90C Acc.to UL-Style 10107/ UL-Std.1581,
min. 20 MOhm x km acc. to UL-Std.1581 CSA C22.2 No 210
Minimum bending radius Sheath colour black (RAL 9005)
flexing 7,5x cable with meter marking Note
fixed installation 3x cable G = with green-yellow conductor
Coupling resistance x = without green-yellow conductor (OZ)
max. 250 Ohm/km 300 mm in adaption
Radiation resistance AWG sizes are approximate equivalent
up to 80x106 cJ/kg (up to 80 Mrad) values. The actual cross-section is in mm.
non screened analogue type:
Single 602-RC-J/O, confer page 501

Application
High flexible special single core screened cables for drag chains are used for flexible use for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms. These two-norm cables primarily designed for exportorientated machinery manufacturer
for flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts. These screened cables are particulary
suitable for the interference-free transmission in instrumentation and control engineering applications (electromagnetic compatibillity). For applications
which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable
trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
69631 1 G 10 8 10,0 130,0 230,0 69643 1 G 95 3/0 22,0 1030,0 1395,0
69632 1 x 10 8 10,0 130,0 230,0 69644 1 x 95 3/0 22,0 1030,0 1395,0
69633 1 G 16 6 11,1 190,0 300,0 69645 1 G 120 4/0 23,6 1285,0 1770,0
69634 1 x 16 6 11,1 190,0 300,0 69646 1 x 120 4/0 23,6 1285,0 1770,0
69635 1 G 25 4 12,3 260,0 420,0 69647 1 G 150 250 kcmil 25,8 1570,0 1930,0
69636 1 x 25 4 12,3 260,0 420,0 69648 1 x 150 250 kcmil 25,8 1570,0 1930,0
69637 1 G 35 2 15,1 405,0 615,0 69649 1 G 185 350 kcmil 29,8 1940,0 2635,0
69638 1 x 35 2 15,1 405,0 615,0 69650 1 x 185 350 kcmil 29,8 1940,0 2635,0
69639 1 G 50 1 17,2 560,0 825,0 69651 1 G 240 450 kcmil 33,5 2530,0 3380,0
69640 1 x 50 1 17,2 560,0 825,0 69652 1 x 240 450 kcmil 33,5 2530,0 3380,0
69641 1 G 70 2/0 19,0 780,0 1090,0 69653 1 G 300 550 kcmil 36,2 3140,0 4120,0
69642 1 x 70 2/0 19,0 780,0 1090,0 69654 1 x 300 550 kcmil 36,2 3140,0 4120,0

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

502
Cables according to international Approvals / Single Conductors UL/CSA

TOPFLEX 304 / 304-C unscreened (double insulated)/ screened


high flexible PVC single core 0,6/1kV for drag chain application

Technical data Cable structure Properties


Special PVC single-core cable TOPFLEX 304 PVC self-extinguishing and flame retardant
Temperature range Bare copper, extra fine wire conductor to acc. to DIN VDE 0482-332-1-2,
flexing -5C to +80C DIN VDE 0295 cl.6 and IEC 60228 cl.6 DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation -40C to +80C PVC insulation, green-yellow DIN VDE 0472 part 804 test method B)
Nominal voltage PVC sheath compound TM2 Chemical resistance see table Technical
U0/U 600/1000 V Sheath colour grey Information
A.c. test voltage, 50 Hz TOPFLEX 304-C
3000 V Construction as above, but
Insulation resistance Tinned copper braid, coverage approx. 85%
min. 20 MOhm x km
Minimum bending radius
for flexible installation
5x cable

Application
Thanks to their outstanding alternating bending stress characteristics, these cables are ideally suited for use in drag chains, and also for use in handling
devices, robots, and nearly any area requiring flexible used and free motion.
TOPFLEX 304-C Optimum compliance with requirements for electromagnetic compatibillity (EMC) by approx. 85% coverage from the braided
screen.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX 304 TOPFLEX 304C
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
79639 1 G 2,5 14 4,5 24,0 42,0 79653 1 G 2,5 14 5,9 40,0 55,0
79640 1G4 12 5,6 38,4 58,0 79654 1G4 12 6,5 50,0 75,0
79641 1G6 10 6,1 57,6 85,0 79655 1G6 10 8,3 88,0 125,0
71544
79642
79643
1 G 10
1 G 16
1 G 25
8
6
4
8,0
9,8
11,8
96,0
154,0
240,0
130,0
190,0
280,0
79656
79657
79658
1 G 10
1 G 16
1 G 25
8
6
4
8,7
10,3
12,4
124,0
190,0
260,0
170,0
300,0
420,0
N
79644 1 G 35 2 12,9 336,0 400,0 79659 1 G 35 2 13,7 405,0 620,0
79645 1 G 50 1 14,6 480,0 520,0 79660 1 G 50 1 15,4 560,0 825,0
79646 1 G 70 2/0 17,5 672,0 720,0 79661 1 G 70 2/0 17,5 780,0 1090,0
79647 1 G 95 3/0 20,0 912,0 1050,0 79662 1 G 95 3/0 21,0 1030,0 1395,0
79648 1 G 120 4/0 21,6 1152,0 1220,0 79685 1 G 120 4/0 22,4 1311,0 1770,0
79649 1 G 150 300 kcmil 23,5 1440,0 1500,0 79663 1 G 150 300 kcmil 24,3 1527,0 1930,0
79650 1 G 185 350 kcmil 25,7 1776,0 1940,0 79664 1 G 185 350 kcmil 26,5 1940,0 2635,0
79651 1 G 240 500 kcmil 29,5 2304,0 2675,0 79665 1 G 240 500 kcmil 30,3 2530,0 3380,0
79652 1 G 300 600 kcmil 32,5 2880,0 3300,0 79666 1 G 300 600 kcmil 35,0 3050,0 3500,0

Dimensions and specifications may be changed without prior notice.

503
Cables according to international Approvals / Single Conductors UL/CSA

MULTISPEED 600-PUR -J/-O special single cores for


drag chains, 1000 V, halogen-free, meter marking

Technical data Cable structure Properties


Special drag chain core line for extreme Bare copper conductor, ultra-fine wire to Flame retardant, UL VW-1, CSA FT1
mechanical stresses adapted to DIN VDE 0295 cl.6, column 4, BS 6360 cl.6 Halogen-free
DIN VDE 0285-525-2-31/ and/or IEC 60228 cl.6 Abrasion resistant
DIN EN 50525-2-31 and UL style 10553 Core insulation of thermoplastic polymer Very good oil resistance
Temperature range in either black or green/yellow Very good alternating bending strength
flexing -30C to +80C Outer sheath of special polyurethane, Very high resistance to mechanical stresses
fixed installation -40C to +80C TMPU adapted to Higher notch resistance
Nominal voltage DIN VDE 0207-363-10-2 / Ozone and UV-resistant
VDE U0/U 600/1000 V DIN EN 50363-10-2 Coolant resistant
UL/CSA 1000 V Sheath colour black (RAL 9005) The materials used in manufacture are
Test voltage 3000 V with meter marking cadmium-free and contain no silicone
Insulation resistance and free from substances harmful to
min. 100 MOhm x km the wetting properties of lacquers
Minimum bending radius
flexing 5x core Note
fixed installation 3x core G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED 600-C-PUR-J/O,
confer page 505

Application
These special drag chain core cables permit extended use with extreme requirements, with free movement, without tensile stresses or forced movements.
Suitable for installation in long traverse paths and high speeds in dry, high temperature influence in dry, moist and wet environments and in the open
air. These cables can be used for all applications demanding the highest requirements in flexibility, abrasion resistance, ozone and chemical resistance.
For applications extending beyond standard solutions (e. g. composting plants or high-lift conveyor systems working at extremely low speeds), we
recommend that you request our questionnaire, which has been especially designed for energy supply systems. Before installation in cable trays please
read the instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
25888 1G6 10 7,2 58,0 80,0 25895 1 G 95 3/0 20,0 912,0 1050,0
25269 1x6 10 7,2 58,0 80,0 25276 1 x 95 3/0 20,0 912,0 1050,0
25889 1 G 10 8 8,4 96,0 130,0 25896 1 G 120 4/0 21,0 1152,0 1240,0
25270 1 x 10 8 8,4 96,0 130,0 25277 1 x 120 4/0 21,0 1152,0 1240,0
25890 1 G 16 6 9,5 154,0 181,0 25897 1 G 150 250 kcmil 23,8 1440,0 1524,0
25271 1 x 16 6 9,5 154,0 181,0 25278 1 x 150 250 kcmil 23,8 1440,0 1524,0
25891 1 G 25 4 11,0 240,0 274,0 25898 1 G 185 350 kcmil 26,2 1776,0 1932,0
25272 1 x 25 4 11,0 240,0 274,0 25279 1 x 185 350 kcmil 26,2 1776,0 1932,0
25892 1 G 35 2 13,0 336,0 398,0 25899 1 G 240 450 kcmil 29,8 2304,0 2467,0
25273 1 x 35 2 13,0 336,0 398,0 25280 1 x 240 450 kcmil 29,8 2304,0 2467,0
25893 1 G 50 1 15,4 480,0 529,0 25900 1 G 300 550 kcmil 33,1 2880,0 3140,0
25274 1 x 50 1 15,4 480,0 529,0 25281 1 x 300 550 kcmil 33,1 2880,0 3140,0
25894 1 G 70 2/0 17,2 672,0 717,0
25275 1 x 70 2/0 17,2 672,0 717,0

Dimensions and specifications may be changed without prior notice. (RN06)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUcond PA6-L
Cable Gland - HELUcond PA6-UL

504
Cables according to international Approvals / Single Conductors UL/CSA

MULTISPEED 600-C-PUR -J/-O special cable for drag


chains, 1000 V, screened, halogen-free, EMC-preferred type, meter marking

Technical data Cable structure Properties


Special drag chain core cable for Bare copper conductor, ultra-fine wire to Flame retardant, UL VW-1, CSA FT1
mechanical stresses adapted to DIN VDE 0295 cl.6, column 4, BS 6360 cl.6 Halogen-free
DIN VDE 0285-525-2-31/ and/or IEC 60228 cl.6 Abrasion resistant
DIN EN 50525-2-31 Core insulation of thermoplastic Very good oil resistance
and UL-Style 10553 polymer in either black or green/yellow Very good alternating bending strength
Temperature range Braided screen of tinned Cu wires, Very high resistance to mechanical
flexing -30C to +80C coverage approx. 85% stresses
fixed installation -40C to +80C Core wrapping with fleece Improved notch resistance
Nominal voltage Outer sheath of special polyurethane Ozone and UV-resistant
VDE U0/U 600/1000 V TMPU adapted to Coolant-resistant
UL/CSA 1000 V DIN VDE 0207-363-10-2 / The materials used in manufacture are
Test voltage 3000 V DIN EN 50363-10-2 cadmium-free and contain no silicone
Insulation resistance Sheath colour black (RAL 9005) and free from substances harmful to
min. 100 MOhm x km with meter marking the wetting properties of lacquers
Minimum bending radius
flexing 5x core Note
fixed installation 3x core G = with green-yellow conductor
x = without green-yellow conductor (OZ)
Please observe applicable installation
regulations for use in energy supply chains.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
MULTISPEED 600-PUR -J/-0,
confer page 504

Application
These special drag chain core cables permit extended use with extreme requirements, with free movement, without tensile stresses or forced movements.
Suitable for installation in long traverse paths and high speeds in dry, high temperature influence in dry, moist and wet environments and in the open
air. These cables can be used for all applications demanding the highest requirements in flexibility, abrasion resistance, ozone and chemical resistance.
N
The copper screening assures a disturbance-free data and signal transmission for measuring and control systems. For applications extending beyond
standard solutions (e. g. composting plants or high-lift conveyor systems working at extremely low speeds), we recommend that you request our
questionnaire, which has been especially designed for energy supply systems. Before installation in cable trays please read the instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
25901 1G6 10 7,8 71,0 101,0 25908 1 G 95 3/0 23,4 1004,0 1190,0
25282 1x6 10 7,8 71,0 101,0 25289 1 x 95 3/0 23,4 1004,0 1190,0
25902 1 G 10 8 9,7 122,0 168,0 25909 1 G 120 4/0 24,5 1260,0 1400,0
25283 1 x 10 8 9,7 122,0 168,0 25290 1 x 120 4/0 24,5 1260,0 1400,0
25903 1 G 16 6 11,7 180,0 217,0 25910 1 G 150 250 kcmil 27,8 1570,0 1710,0
25284 1 x 16 6 11,7 180,0 217,0 25291 1 x 150 250 kcmil 27,8 1570,0 1710,0
25904 1 G 25 4 13,2 282,0 342,0 25911 1 G 185 350 kcmil 29,4 1911,0 2021,0
25285 1 x 25 4 13,2 282,0 342,0 25292 1 x 185 350 kcmil 29,4 1911,0 2021,0
25905 1 G 35 2 15,2 386,0 468,0 25912 1 G 240 450 kcmil 34,2 2451,0 2601,0
25286 1 x 35 2 15,2 386,0 468,0 25293 1 x 240 450 kcmil 34,2 2451,0 2601,0
25906 1 G 50 1 18,7 535,0 584,0 25913 1 G 300 550 kcmil 37,4 2997,0 3257,0
25287 1 x 50 1 18,7 535,0 584,0 25294 1 x 300 550 kcmil 37,4 2997,0 3257,0
25907 1 G 70 2/0 21,2 750,0 822,0
25288 1 x 70 2/0 21,2 750,0 822,0

Dimensions and specifications may be changed without prior notice. (RN06)

505
Cables according to international Approvals / Single Conductors UL/CSA

TOPFLEX 301 / 301-C unscreened (double insulated)/ screened


high flexible PUR single core 0,6/1kV for drag chain application

Technical data Cable structure Properties


TOPFLEX 301 (unscreened) TOPFLEX 301 (unscreened) PUR outer sheath: low adhesion, flame
Special PUR single-core cable acc. to Bare copper, extra fine wire conductor to retardant, extremely abrasion resistant,
UL AWM Style 10553 DIN VDE 0295 cl.6 and IEC 60228 cl.6 resistant to UV, oil, hydrolysis and microbial
Temperature range Cold resistant PVC core insulation, grey attack
flexing -15C to +80C PUR outer sheath Optimised insulation materials ensure
Nominal voltage Sheath colour black or green yellow resistance to oils (including mineral oils),
acc. to VDE U0/U 600/1000 V TOPFLEX 301-C (screened) greases, coolants, hydraulic fluids as well
acc. to UL 1000 V Structure as per TOPFLEX 301, but as many alkalis and solvents
A.C. test voltage3000 V additionally The optimised external diameter and the
Insulation resistance Fleece wrapping between screen and reduced weight facilitate use in multi-shift
min. 20 MOhm x km sheath operation with extreme alternating
Minimum bending radius Tinned copper braided screening, bending stress cycles
7,5 cable approx. 85% coverage Thanks to its excellent mechanical
TOPFLEX 301-C (screened) Sheath colour black characteristics, the wear-resistant,
Tech. data as per TOPFLEX 301 notch-resistant, flame-retardant PUR
Coupling resistance sheath provides high functional reliability
max. 250 Ohm/km over long periods

Application
TOPFLEX 301 (unscreened) These cables are specially designed for use in energy supply chains, automated handling equipment, robots, machine
tools, processing and manufacturing machinery.
TOPFLEX 301-C (screened) Applications as described above, additionally optimal compliance with electromagnetic compatibillity (EMC) requirements
on account of the approx. 85% coverage by the braided screening.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX 301 double insulated, black unscreened TOPFLEX 301-C black screened EMC
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
75375 1x6 10 7,1 58,0 85,0 75399 1x6 10 7,8 95,0 144,0
75376 1 x 10 8 8,8 96,0 130,0 75400 1 x 10 8 9,5 124,0 170,0
75377 1 x 16 6 10,5 154,0 190,0 75401 1 x 16 6 10,8 186,0 220,0
75378 1 x 25 4 11,2 240,0 280,0 75402 1 x 25 4 12,2 278,0 340,0
75379 1 x 35 2 13,5 336,0 400,0 75403 1 x 35 2 13,7 384,0 460,0
75380 1 x 50 1 15,8 480,0 520,0 75404 1 x 50 1 15,4 530,0 580,0
75381 1 x 70 2/0 18,0 672,0 720,0 75405 1 x 70 2/0 17,6 753,0 820,0
75382 1 x 95 3/0 20,4 912,0 1050,0 75406 1 x 95 3/0 21,7 1006,0 1200,0
75383 1 x 120 4/0 22,2 1152,0 1220,0 75407 1 x 120 4/0 22,4 1257,0 1350,0
75384 1 x 150 300 kcmil 25,0 1440,0 1500,0 75408 1 x 150 300 kcmil 24,3 1562,0 1680,0
75385 1 x 185 350 kcmil 28,0 1776,0 1940,0 75409 1 x 185 350 kcmil 26,5 1895,0 2100,0
75386 1 x 240 500 kcmil 32,5 2304,0 2645,0 75410 1 x 240 500 kcmil 30,3 2704,0 3100,0

TOPFLEX 301 double insulated, green-yellow unscreened


Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app.
mm kg / km kg / km
75387 1G6 10 7,1 58,0 85,0
75388 1 G 10 8 8,8 96,0 130,0
75389 1 G 16 6 10,5 154,0 190,0
75390 1 G 25 4 11,2 240,0 280,0
75391 1 G 35 2 13,5 336,0 400,0
75392 1 G 50 1 15,8 480,0 520,0
75393 1 G 70 2/0 18,0 672,0 720,0
75394 1 G 95 3/0 20,4 912,0 1050,0
75395 1 G 120 4/0 22,2 1152,0 1220,0
75396 1 G 150 300 kcmil 25,0 1440,0 1500,0
75397 1 G 185 350 kcmil 28,0 1776,0 1940,0
75398 1 G 240 500 kcmil 32,5 2304,0 2645,0

Dimensions and specifications may be changed without prior notice.

506
BRITISH STANDARD CABLES
Cables according to international Approvals / Cables to British Standard

HELUKABEL BS 5308 Part 1 Instruments cable,


core insulation PE or XLPE

Technical data Cable structure Note


Instrument cable acc. to Copper conductor, single-, multiple-, or As a result of a wide range of cables and wires
British Standard 5308 Part 1 fine-wire acc. to BS 6360 acc. to British Standard, you can find following
Temperature range Conductor cross-sections from 0,5 mm only a small selection of types.
fixed installation -20C to +65C to 1,5 mm For request about British Standard cables please
Nominal voltage Core insulation contact us under
U0/U 300/500 V - Polyethylene acc. to BS 6234 Type 03 or Ph. 0049 7150 9209-786
Minimum bending radius - XLPE (cross-linked polyethylene for LSZH E-Mail: [email protected]
fixed installation cable)
5x outer (type 1) Cores stranded in pairs with
6x outer (type 2+3) optimal lay-length,
Lay-length smaller than 100 mm
Number of pairs: 1,2,5,10,15,20,30,50
Pairs individually not screened or screened
Pairs stranded in layers
Wrapping with aluminium/polyester foil, on
request
Type 1
Flame retardant PVC outer sheath or LSZH
Type 2
Extruded polyethylene inner sheath,
steel wire armouring,
Flame retardant PVC outer sheath or LSZH
Type 3
PVC inner sheath,
steel wire armouring,
PVC outer sheath
Sheath colour black or blue

Application
As measurement and control cables in power plants and industrial plants, and in the petrochemical industry. Example BS 5308 P1 T1 CU / PE / CAM
/ PVC = Overall screening, sheath PVC BS 5308 P1 T2 CU / XLPE / IAM / CAM / LSZH / SWA / LSZH = Pair screened, Overall screening, galvanic
round steel wire, halogen free
Dimensions and specifications may be changed without prior notice.

508
Cables according to international Approvals / Cables to British Standard

HELUKABEL BS 5308 Part 2 Instruments cable, core insulation PVC

Technical data Cable structure Note


Instrument cable acc. to Copper conductor, single-, multiple-, or As a result of a wide range of cables and wires
British Standard 5308 Part 2 fine-wire acc. to BS 6360 acc. to British Standard, you can find
Temperature range Conductor cross-sections from following only a small selection of types.
fixed installation -20C to +65C 0,5 mm to 1,5 mm For request about British Standard cables
Nominal voltage Core insulation PVC acc. to BS 6746 please contact us under
U0/U 300/500 V Cores stranded in pairs with Ph. 0049 7150 9209-786
Minimum bending radius optimal lay-length E-Mail: [email protected]
fixed installation Lay-length smaller than 100 mm
5x outer (type 1) Number of pairs: 1,2,5,10,20,30,50
6x outer (type 2) Pairs individually screened with
aluminium-foil or unscreened
Pairs stranded in layers
Wrapping with aluminium/polyester foil,
on request
Type 1
Flame retardant PVC outer sheath
Type 2
Extruded PVC inner sheath,
steel wire armouring,
Flame retardant PVC outer sheath
Sheath colour black or blue

Application
As measurement and control cables in power plants and industrial plants, and in the petrochemical industry. Example BS 5308 P2 T2 CU / PVC /
CAM / PVC / SWA / PVC = Overall screening, steel wire armouring
Dimensions and specifications may be changed without prior notice.

509
Cables according to international Approvals / Cables to British Standard

HELUKABEL BS 5467 High voltage cable 0,6/1kV, armoured, sheath PVC

Technical data Cable structure Properties


Special power cable acc. to Bare copper conductor acc. to BS 6360 cl.2 Reaction to fire tested acc. to IEC 60332-1,
British Standard 5467 Core insulation of cross-linked polyethylene BS 4066-1
Temperature range Core identification
flexing 0C to +90C 1-core - brown Note
fixed installation -15C to +90C 2-core - brown, blue As a result of a wide range of cables and wires
Nominal voltage 3-core - brown, blue, grey acc. to British Standard, you can find
U0/U 600/1000 V 4-core - brown, black, grey, blue following only a small selection of types.
Minimum bending radius 5-core and up with numbering For request about British Standard cables
fixed installation Cores stranded layers please contact us under
up to 16 mm 6x outer PVC-Inner sheath Ph. 0049 7150 9209-786
> 25 mm 8x outer Amouring of galvanized steel wire E-Mail: [email protected]
PVC-Outer sheath
Sheath colour black

Application
As a control and power cable in industrial enviroments. Thanks to the amouring of galvanized steel wire, can be used anywhere that a high level of
mechanical protection is required. Suitable for use outdoors and in the earth.
Example
BS 5467 CU / XLPE / PVC / AWA / PVC = Singlecore
BS 5467 CU / XLPE / PVC / SWA / PVC = Multicore
Dimensions and specifications may be changed without prior notice.

510
Cables according to international Approvals / Cables to British Standard

HELUKABEL BS 6724 High voltage cable 0,6/1kV, armoured, halogen-free

Technical data Cable structure Properties


Special power cable acc. to Bare copper conductor acc. to BS 6360 cl.2 Reaction to fire tested acc. to IEC 60332-3,
British Standard 6724 Core insulation of cross-linked polyethylene BS 4066-1
Temperature range Core identification
flexing 0C to +90C 1-core - brown Note
fixed installation -20C to +90C 2-core - brown, blue As a result of a wide range of cables and wires
Permissible operating temperature 3-core - brown, black, grey acc. to British Standard, you can find
at conductor +90C 4-core - brown, black, grey, blue following only a small selection of types.
Nominal voltage 5-core and up with numbering For request about British Standard cables
U0/U 600/1000 V Cores stranded layers please contact us under
Minimum bending radius Inner sheath LSHF mix Ph. 0049 7150 9209-786
fixed installation Amouring of galvanized steel wire E-Mail: [email protected]
up to 16 mm 6x outer Outer sheath LSHF mix
> 25 mm 8x outer Sheath colour black

Application
Unlike power cables acc. to BS 5467, these are LSHF (Low Smoke Halogen Free). Used anywhere where in case of fire damage to human life and
material assets must be prevented, e.g. in industrial plants, airports, underground railways and tunnels.
Example
BS 6724 CU / XLPE / LSZH / AWA / LSZH = Singelcore
BS 6724 CU / XLPE / LSZH / SWA / LSZH = Multicore
Dimensions and specifications may be changed without prior notice.

511
Table of contents

04 | | 512
INFRASTRUCTURE CABLES & WIRES

Installation cables 514

Telephone & fire warning cables 522

Power, security & medium voltage cables 534

513
INSTALLATION CABLES

Designation Properties Approvals Page

YV patch cable / YR bell sheathed cable in accordance with VDE 0812 516

NYM-J/-O PVC sheathed cable VDE approved 517

(N) YM (St)-J PVC sheathed cable screened 518

NHMH-O halogen-free, i.e. free of harmful substances, sheathed cable 300/500V 519

NHMH-J halogen-free, i.e. free of harmful substances, sheathed cable 300/500V 520

NHXHM-O/-J halogen-free sheathed cable 300/500 V, VDE approved 521

515
Installation Cables

YV-Equipment Wires / YR-Bell Sheathed


Cables
according to VDE 0812

Technical data Cable structure Properties


YV-Equipment Wires YV-Equipment Wires YV-Equipment Wires
Equipment wires with PVC core Tinned copper-conductor, Tests
insulation to DIN VDE 0812 solid 0,3 to 1,8 mm PVC self-extinguishing and flame retardant
Temperature range Core insulation of PVC acc. to IEC 60332-2 (equivalent
flexing -5C to +70C compound type YI3 to DIN VDE 0472 part 804 test method A)
fixed installation -30C to +70C DIN VDE 0207 part 4 Installation notes
Electrical characteristics Mono or twin colour wires, twin colour The equipment wires are to be so uncoiled
Operating voltage (peak voltage) wires have a base colour with the second from drums or coils so that no kinks or
to DIN VDE 0812 colour superimposed in ring form twisting torsional stress can be occured
YR-Bell Sheathed Cables Core identification to DIN 47002 Those are allowed to install as
adapted to DIN VDE 0812 YR-Bell Sheathed Cables self-supporting shaped wires
Minimum bending radius Bare copper conductor, solid 0,8 mm independently ensuring the
15x cable Cores stranded in layer free-movements so as to gain a
Core identification compensating bending
see Technical Informations These are used without any mechanical
Outer sheath of PVC stress, pull, pressure, abrasion and notch
Sheath colour white Several equipment wires are used together
in form of a bunch.
The insulating coverings are not be cut
through the binding materials.
The binding materials must be
nonconductive and not allowed to swell or
shrink in humidity.
During the soldering process without
jointing clamp, the soldering period is to
be shortened so that the insulating
covering should not be shrinked or injured.

Application
YV-Equipment Wires Single core cables for use in small apparatus, switching and intercom system and for data transmission. These cables are not
allowed for the installation of heavy current operation. Equipment wire are used for wiring to the switchbords, amplifiers and dial intercommunicating
systems, measuring instruments, telephone exchange, clock centrals and data processing apparatus etc. These wires are not permitted to apply outside
of equipment for high power ratings.
YR-Bell Sheathed Cables For different applications up to max. 100 V operating voltage, for fixed installation above and beneath plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
YV-Equipment Wires YR-Bell Sheathed Cables
Part no. No.cores x Outer Cop. Weight Part no. No.cores x Outer Cop. Weight
cond. / core approx. mm weight approx. cond. / core approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
28900 1 x 0,3 / 0,7 0,7 0,7 1,2 - 28919 2 x 0,8 / 1,4 4,0 9,6 27,0 -
28901 2 x 0,3 / 0,7 1,4 1,4 2,4 - 28920 3 x 0,8 / 1,4 4,4 14,4 33,0 -
28902 3 x 0,3 / 0,7 1,6 2,1 3,6 - 28921 4 x 0,8 / 1,4 4,9 19,2 41,0 -
28903 1 x 0,4 / 0,8 0,8 1,3 1,8 - 28922 5 x 0,8 / 1,4 5,3 24,0 48,0 -
28904 2 x 0,4 / 0,8 1,6 2,5 3,6 - 28923 6 x 0,8 / 1,4 5,8 28,8 56,0 -
28905 3 x 0,4 / 0,8 1,8 3,8 5,4 - 28924 8 x 0,8 / 1,4 6,5 38,0 70,0 -
28906 1 x 0,5 / 0,9 0,9 2,0 2,5 - 28925 10 x 0,8 / 1,4 7,6 48,0 84,0 -
28907 2 x 0,5 / 0,9 1,8 3,9 5,0 - 28926 12 x 0,8 / 1,4 7,7 58,0 98,0 -
28908 3 x 0,5 / 0,9 2,0 5,9 7,5 - 28927 16 x 0,8 / 1,4 8,6 77,0 124,0 -
28909 4 x 0,5 / 0,9 2,2 7,9 10,0 - 28928 24 x 0,8 / 1,4 10,5 115,0 188,0 -
28910 1 x 0,8 / 1,4 1,4 5,0 6,0 -
28911 2 x 0,8 / 1,4 2,8 10,0 12,0 -
28912 3 x 0,8 / 1,4 3,0 15,0 18,0 -
28913 4 x 0,8 / 1,4 3,4 20,0 24,0 -
28914 1 x 1 / 1,8 1,8 7,9 10,0 -
28915 2 x 1 / 1,8 3,6 16,0 20,0 -
28916 3 x 1 / 1,8 4,0 24,0 30,0 -
28917 1 x 1,4 / 2,2 2,2 15,0 17,0 -
28918 1 x 1,8 / 2,8 2,8 25,0 27,5 -

Dimensions and specifications may be changed without prior notice. (RO01)

516
Installation Cables

NYM-J/-O PVC-Sheathed Cable VDE approved

Technical data Cable structure Properties


PVC-sheathed cable to Solid or stranded, plain copper conductor Tests
DIN VDE 0250 part 204 to DIN VDE 0295 cl.1 or cl.2, BS 6360 PVC self-extinguishing and flame retardant
Temperature range cl.1 or cl.2 and IEC 60228 cl.1 or cl.2 acc. to DIN VDE 0482-332-1-2,
flexing +5C to +70C Core insulation of PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation -40C to +70C compound type TI1 to DIN VDE 0472 part 804 test method B)
Nominal voltage DIN VDE 0207-363-3 / DIN EN 50363-3
U0/U 300/500 V Core identification to Note
Test voltage 2000 V DIN VDE 0293-308 re = round conductor, single-wire
Minimum bending radius Cores stranded in layers with rm = round conductor, multi-wire
fixed installation 4x cable optimal lay-length G = with green-yellow conductor
Radiation resistance Filler x = without green-yellow conductor (OZ)
up to 80x106 cJ/kg (up to 80 Mrad) Outer sheath of PVC AWG sizes are approximate equivalent
Caloric load values compound type TM1 to values. The actual cross-section is in mm.
see Technical Informations DIN VDE 0207-363-4-1 /
DIN EN 50363-4-1
Sheath colour grey (RAL 7035)

Application
For industrial- and wiring purposes. Usable in the open, in dry, damp and wet environments in the open and concealed, as well as in masonry and in
beton, not suitable for imbedding in solidified- or compressed-concrete. Outdoor usage is only possible, as long as the cable is protected against direct
sunlight.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. kg / km cross-sec. approx. mm weight approx. kg / km
mm kg / km mm kg / km
39050 1 G 1,5 re 5,4 14,4 40,0 16 39061 4G6 re 15,1 230,0 460,0 10
39001 1 x 1,5 re 5,4 14,4 40,0 16 39012 4x6 re 15,1 230,0 460,0 10
39006 2 x 1,5 re 8,7 29,0 170,0 16 39069 5G6 re 16,1 288,0 540,0 10
39056 3 G 1,5 re 9,1 43,0 135,0 16 39020 5x6 re 16,1 288,0 540,0 10
39007 3 x 1,5 re 9,1 43,0 135,0 16 39053 1 G 10 re 8,4 96,0 155,0 8
39058 4 G 1,5 re 9,8 58,0 160,0 16 39004 1 x 10 re 8,4 96,0 155,0 8
39009 4 x 1,5 re 9,8 58,0 160,0 16 39062 4 G 10 re 17,6 384,0 680,0 8
39066 5 G 1,5 re 10,3 72,0 190,0 16 39013 4 x 10 re 17,6 384,0 680,0 8
39017 5 x 1,5 re 10,3 72,0 190,0 16 39070 5 G 10 re 19,2 480,0 850,0 8
39072
39023
39076
7 G 1,5
7 x 1,5
10 G 1,5 re
re
re
11,5
11,5
13,8
101,0
101,0
144,0
235,0
235,0
330,0
16
16
16
39021
39054
39005
5 x 10
1 G 16
1 x 16
re
rm
rm
19,2
9,9
9,9
480,0
154,0
154,0
850,0
230,0
230,0
8
6
6
O
39077 12 G 1,5 re 14,4 173,0 405,0 16 39063 4 G 16 rm 21,3 614,0 1048,0 6
39055 1 G 2,5 re 6,0 24,0 70,0 14 39014 4 x 16 rm 21,3 614,0 1048,0 6
39024 1 x 2,5 re 6,0 24,0 70,0 14 39071 5 G 16 rm 23,4 768,0 1280,0 6
39057 3 G 2,5 re 10,4 72,0 190,0 14 39022 5 x 16 rm 23,4 768,0 1280,0 6
39008 3 x 2,5 re 10,4 72,0 190,0 14 39079 1 G 25 rm 12,0 240,0 325,0 4
39059 4 G 2,5 re 11,3 96,0 230,0 14 39064 4 G 25 rm 25,8 960,0 1649,0 4
39010 4 x 2,5 re 11,3 96,0 230,0 14 39015 4 x 25 rm 25,8 960,0 1649,0 4
39067 5 G 2,5 re 12,0 120,0 270,0 14 39073 5 G 25 rm 28,7 1200,0 1970,0 4
39018 5 x 2,5 re 12,0 120,0 270,0 14 39065 4 G 35 rm 28,5 1344,0 2000,0 2
39075 7 G 2,5 re 13,2 168,0 342,0 14 39016 4 x 35 rm 28,5 1344,0 2000,0 2
39051 1G4 re 6,6 38,0 80,0 12
39002 1x4 re 6,6 38,0 80,0 12
39074 3G4 re 12,0 115,0 258,0 12
39060 4G4 re 13,0 154,0 330,0 12
39011 4x4 re 13,0 154,0 330,0 12
39068 5G4 re 14,5 192,0 410,0 12
39019 5x4 re 14,5 192,0 410,0 12
39052 1G6 re 7,2 58,0 105,0 10
39003 1x6 re 7,2 58,0 105,0 10
39078 3G6 re 13,0 173,0 320,0 10

Dimensions and specifications may be changed without prior notice. (RO01)

517
Installation Cables

(N)YM(St)-J PVC-sheathed cable screened

Technical data Cable structure Properties


screened PVC-sheathed cable Bare copper-conductor, to Tests
adapted to DIN VDE 0250 part 204 DIN VDE 0295 cl.1 or cl.2, single-wire PVC self-extinguishing and flame retardant
Temperature range or multi-wire, BS 6360 cl.1 or cl.2, acc. to DIN VDE 0482-332-1-2,
flexing +5C to +70C IEC 60228 cl.1 or cl.2 DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation -40C to +70C Core insualtion of PVC DIN VDE 0472 part 804 test method B)
Permissible working temperature compound type TI1 to
at the conductor +70C DIN VDE 0207-363-4-1/DIN EN 50363-4-1 Note
Nominal voltage Core identification to DIN VDE 0293-308 re = round conductor, single-wire
U0/U 300/500 V Cores stranded in layers with rm = round conductor, multi-wire
Test voltage 2000 V optimal lay-length Also availabel in an halogen-free version
Minimum bending radius Solid copper drain-wire, tinned AWG sizes are approximate equivalent
fixed installation 4x cable Coated aluminium foil screening values. The actual cross-section is in mm.
Radiation resistance Outer sheath of PVC
up to 80x106 cJ/kg (up to 80 Mrad) compound type TM1 to
DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Sheath colour grey (RAL 7035)

Application
These installation cables are made for an effective range of electromagnetic interference alternating fields by a static screen. This screening is specially
used for the installation in computer sector, hospitals or industry measuring observation points with measuring instruments which are sensitive to
interferences. These cables are also ideal for installations in the living rooms of those peoples who are extreme sensitive to radiation. The cable is
suitable for laying on, in and under plaster in dry and damp places as well as in concrete and masonry (a direct laying in shaked or stamped concrete
is excluded). Outdoor laying only is possible if the cable is not exposed to direct sunlight or if the cable is layed in cable conduits. Use in dangerous
areas is not allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Drain- Outer Cop. Weight AWG-No. Part no. No.cores x Drain- Outer Cop. Weight AWG-No.
cross-sec. wire approx. weight approx. cross-sec. wire approx. weight approx.
mm mm mm kg / km kg / km mm mm mm kg / km kg / km
43050 3 G 1,5 re 1,5 10,5 51,0 154,0 16 43063 5 G 10 re 1,5 21,5 485,0 840,0 8
43051 4 G 1,5 re 1,5 11,5 63,0 184,0 16 43064 5 G 16 rm 2,5 26,0 773,0 1353,0 6
43052 5 G 1,5 re 1,5 12,0 80,0 208,0 16 43065 5 G 25 rm 2,5 31,5 1205,0 2017,0 4
43053 7 G 1,5 re 1,5 13,0 106,0 250,0 16
43054 3 G 2,5 re 1,5 12,0 80,0 217,0 14
43055 4 G 2,5 re 1,5 13,0 104,0 256,0 14
43056 5 G 2,5 re 1,5 13,5 128,0 280,0 14
43057 3G4 re 1,5 13,5 123,0 228,0 12
43058 4G4 re 1,5 14,5 159,0 359,0 12
43059 5G4 re 1,5 16,5 200,0 440,0 12
43060 3G6 re 1,5 15,0 187,0 378,0 10
43061 4G6 re 1,5 16,5 235,0 477,0 10
43062 5G6 re 1,5 17,5 293,0 565,0 10

Dimensions and specifications may be changed without prior notice. (RO01)

Suitable accessories can be found in Chapter X.


Tool - DUO Stripper 200

518
Installation Cables

NHMH-O halogen-free for fixed installation, emission-free, 300/500 V

Technical data Cable structure Properties


Plastic-sheathed cable, halogen-free, for Bare copper-conductor, Tests
fixed installation to DIN VDE 0250 part 215 single-wire or multi-wire Corrosive nature of combustion gases
Permissible working temperature Core insulation of halogen-free (halogen-free verification)
at the conductor +70C thermoplastic polymer compound testing acc. to DIN VDE 0482 part 267,
Nominal voltage with optimum wall thickness DIN EN 50267-2-2, IEC 60754-2, HD 602
U0/U 300/500 V Core identification to DIN VDE 0293-308 (equivalent DIN VDE 0472 part 813)
Minimum bending radius 1-core version - core colour BK Behaviour in fire self-extinguishing and
fixed installation 4x cable Cores stranded in layer flame retardant to DIN VDE 0482-332-1-2,
Caloric load values Outer sheath of non-cross-linked, DIN EN 60332-1-2,IEC 60332-1 (equivalent
see Technical Informations halogen-free thermoplastic polymer DIN VDE 0472 part 804 test method B)
compound Low smoke
Sheath colour grey (RAL 7035) testing acc. to DIN VDE 0472 part 818

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
x = without green-yellow conductor
O-version: single-core conductor with
black core insulation. Cables between two
and seven cores are without gn-ye core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This plastic-sheathed cable of defined behaviour in case of fire is used for installations in residential dwellings, public buildings as well as in industrial
constructions. Suitable for applications in dry, damp or wet environments for installation above, on, in and beneath plaster, as well as in masonry and
concrete walls, not however for embedding in vibration, compacted or tamped concrete. The cable is also approved for outdoor applications provided
these are not exposed to direct sunlight radiation. Installation of this cable in earth or in water is not permitted.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. kg / km cross-sec. approx. mm weight approx. kg / km

O
mm kg / km mm kg / km
51970 1 x 1,5 re 8,3 14,4 39,0 16 51974 1 x 10 re 11,5 96,0 125,0 8
51976 2 x 1,5 re 8,9 29,0 82,0 16 51980 2 x 10 re 14,9 192,0 340,0 8
51981 3 x 1,5 re 9,2 43,0 92,0 16 51987 4 x 10 re 17,5 384,0 522,0 8
51983 4 x 1,5 re 9,9 58,0 115,0 16 51975 1 x 16 rm 12,9 154,0 188,0 6
51991 7 x 1,5 re 11,5 101,0 167,0 16 51988 4 x 16 rm 19,9 614,0 815,0 6
51971 1 x 2,5 re 9,0 24,0 47,0 14 51989 4 x 25 rm 27,4 960,0 1305,0 4
51977 2 x 2,5 re 10,0 48,0 110,0 14 51990 4 x 35 rm 30,4 1344,0 1750,0 2
51982 3 x 2,5 re 10,6 72,0 128,0 14
51984 4 x 2,5 re 11,0 96,0 152,0 14
51972 1x4 re 9,5 38,0 62,0 12
51978 2x4 re 11,5 77,0 160,0 12
51985 4x4 re 13,4 154,0 244,0 12
51973 1x6 re 10,0 58,0 83,0 10
51979 2x6 re 12,4 115,0 208,0 10
51986 4x6 re 15,9 230,0 345,0 10

Dimensions and specifications may be changed without prior notice. (RO01)

Suitable accessories can be found in Chapter X.


Tool - DUO Stripper 200

519
Installation Cables

NHMH-J halogen-free for fixed installation, emission-free, 300/500 V

Technical data Cable structure Properties


Plastic-sheathed cable, halogen-free, for Bare copper-conductor, Corrosive nature of combustion gases
fixed installation to DIN VDE 0250 part 215 single-wire or multi-wire (halogen-free verification)
Permissible working temperature Core insulation of halogen-free testing acc. to DIN VDE 0482 part 267,
at the conductor +70C thermoplastic polymer compound DIN EN 50267-2-2, IEC 60754-2, HD 602
Nominal voltage with optimum wall thickness (equivalent DIN VDE 0472 part 813)
U0/U 300/500 V Core identification to DIN VDE 0293-308 Behaviour in fire self-extinguishing and
Minimum bending radius 1-core version - core colour GN-YE flame retardant to DIN VDE 0482-332-1-2,
fixed installation 4x cable GN-YE conductor, 3 cores and above DIN EN 60332-1-2,IEC 60332-1 (equivalent
Caloric load values Cores stranded in layer DIN VDE 0472 part 804 test method B)
see Technical Informations Outer sheath of non-cross-linked, Low smoke
halogen-free thermoplastic polymer testing acc. to DIN VDE 0472 part 818
compound
Sheath colour grey (RAL 7035) Note
re = round conductor, single-wire
rm = round conductor, multi-wire
G = with green-yellow conductor
J-version: with green-yellow core
insulation.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
This plastic-sheathed cable of defined behaviour in case of fire is used for installations in residential dwellings, public buildings as well as in industrial
constructions. Suitable for applications in dry, damp or wet environments for installation above, on, in and beneath plaster, as well as in masonry and
concrete walls, not however for embedding in vibration, compacted or tamped concrete. The cable is also approved for outdoor applications provided
these are not exposed to direct sunlight radiation. Installation of this cable in earth or in water is not permitted.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. kg / km cross-sec. approx. mm weight approx. kg / km
mm kg / km mm kg / km
51996 3 G 1,5 re 9,4 43,0 92,0 16 52014 5 G 16 rm 23,8 768,0 995,0 6
52001 4 G 1,5 re 10,2 58,0 115,0 16 52007 4 G 25 rm 27,0 960,0 1305,0 4
52009 5 G 1,5 re 10,8 72,0 133,0 16 52015 5 G 25 rm 29,0 1200,0 1580,0 4
52016 7 G 1,5 re 11,4 101,0 168,0 16 52008 4 G 35 rm 29,9 1344,0 1750,0 2
51997 3 G 2,5 re 10,4 72,0 128,0 14
52002 4 G 2,5 re 11,3 96,0 152,0 14
52010 5 G 2,5 re 11,9 120,0 182,0 14
52017 7 G 2,5 re 13,5 158,0 250,0 14
51992 1G4 re 8,6 38,0 62,0 12
51998 3G4 re 11,8 115,0 192,0 12
52003 4G4 re 13,3 154,0 244,0 12
52011 5G4 re 14,8 192,0 300,0 12
51993 1G6 re 9,9 58,0 83,0 10
51999 3G6 re 13,4 173,0 267,0 10
52004 4G6 re 14,8 230,0 345,0 10
52012 5G6 re 16,0 288,0 400,0 10
51994 1 G 10 re 11,2 96,0 125,0 8
52000 3 G 10 re 16,0 288,0 628,0 8
52005 4 G 10 re 17,4 384,0 522,0 8
52013 5 G 10 re 18,9 480,0 620,0 8
51995 1 G 16 rm 11,9 154,0 188,0 6
52006 4 G 16 rm 21,6 614,0 815,0 6

Dimensions and specifications may be changed without prior notice. (RO01)

Suitable accessories can be found in Chapter X.


Tool - DUO Stripper 200

520
Installation Cables

NHXMH-O/-J halogen-free plastic sheathed cable 300/500 V, VDE approved

Technical data Cable structure Properties


Halogen-free plastic-sheathed cable Bare copper-conductor to Flame-retardant
with enhanced characteristics in case DIN VDE 0295, BS 6360, IEC 60228 Halogen-free, no liberation of corrosive
of fire, acc. to DIN VDE 0250 part 214 up to 10 mm cl.1: single-wire or toxic gases
Conductor resistance (at 20C) 16-35 mm cl.2: multi-wire Limited propagation of fire
acc. to DIN VDE 0295 and IEC 60228 Core insulation of cross-linked Low smoke development
Max. temperature at the conductor polymer, compound type 2XI1 Ozone resistant
during operation +70C to DIN VDE 0207 part 22 Tests
in case of short circuit +250C Core identification to DIN VDE 0293-308 Flame test acc. to
Temperature range 1-core version - core colour BK or GN-YE DIN VDE 0482-332-3, BS 4066 part 3,
during installation -5C to +50C Cores stranded in layers with DIN EN 60332-3, IEC 60332-3 (previously
fixed installation -30C to +70C optimal lay-length DIN VDE 0472 part 804 test method C)
Nominal voltage Overall core sheath of halogen-free Corrosiveness of combustion gases
U0/U 300/500 V filling compound (may be omitted acc. to DIN VDE 0482 part 267,
Test voltage 2000 V for single-core cables) DIN EN 50267-2-2, IEC 60754-2
Minimum bending radius Outer sheath of flame-retardant, (equivalent DIN VDE 0472 part 813)
fixed installation 4x cable halogen-free polymer Halogen-free acc. to DIN VDE 0482 part 267,
Caloric load values compound type HM2 to DIN EN 50267-2-1, IEC 60754-1
see Technical Informations DIN VDE 0207 part 24 (equivalent DIN VDE 0472 part 815)
Sheath colour grey (RAL 7035) Smoke density acc. to DIN VDE 0482
part 268, HD 606, EN 50268-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(equivalent DIN VDE 0472 part 816)
Ozone resistance acc. to
DIN VDE 0472 part 805
Also deliverable in screened (St) version

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
LS0H = Low Smoke Zero Halogen
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application O
Halogen-free plastic-sheathed cables with enhanced characteristics in case of fire are used for applications where harm to human life and damage to
property must be prevented in the event of fire, e. g. in industrial installations, communal establishments, hotels, airports, underground stations,
railway stations, hospitals, departmental stores, banks, schools, theatres, multi-storey buildings, process control centres etc. Suitable for installation
in dry, damp or wet environments, for installation above, on, in and beneath plaster as well as in masonry walls and in concrete, not however for direct
embedding in vibration, compacted or tamped concrete. These cables are also suitable for outdoor applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
NHXMH-O NHXMH-J
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. kg / km cross-sec. min. - max. weight approx. kg / km
mm mm kg / km mm mm kg / km
53300 1 x 1,5 re 5,0 - 8,4 15,0 49,0 16 53192 1G4 re 6,0 - 9,5 39,0 80,0 12
53306 2 x 1,5 re 7,6 - 9,2 29,0 110,0 16 53352 3G4 re 10,1 - 12,2 115,0 235,0 12
53301 1 x 2,5 re 5,4 - 8,8 24,0 60,0 14 53360 4G4 re 11,3 - 13,7 154,0 300,0 12
53307 2 x 2,5 re 8,4 - 10,1 48,0 136,0 14 53368 5G4 re 12,5 - 15,1 192,0 345,0 12
53302 1x4 re 6,0 - 9,5 39,0 80,0 12 53193 1G6 re 6,4 - 10,0 58,0 111,0 10
53308 2x4 re 9,6 - 11,6 77,0 202,0 12 53353 3G6 re 11,5 - 13,9 173,0 323,0 10
53303 1x6 re 6,4 - 10,0 58,0 111,0 10 53361 4G6 re 12,7 - 15,3 230,0 400,0 10
53304 1 x 10 re 7,4 - 11,3 96,0 160,0 8 53369 5G6 re 13,7 - 16,6 288,0 475,0 10
53305 1 x 16 rm 8,5 - 12,4 154,0 232,0 6 53194 1 G 10 re 7,4 - 11,3 96,0 160,0 8
53354 3 G 10 re 13,8 - 16,7 288,0 485,0 8
NHXMH-J 53362 4 G 10 re 15,1 - 18,2 384,0 603,0 8
Part no. No.cores x Outer Cop. Weight AWG-No. 53370 5 G 10 re 16,3 - 19,7 480,0 720,0 8
cross-sec. min. - max. weight approx. kg / km 53195 1 G 16 rm 8,5 - 12,4 154,0 232,0 6
mm mm kg / km 53355 3 G 16 rm 16,5 - 20,0 461,0 850,0 6
53350 3 G 1,5 re 8,0 - 9,6 43,0 130,0 16 53363 4 G 16 rm 18,0 - 21,8 615,0 940,0 6
53358 4 G 1,5 re 8,5 - 10,3 58,0 151,0 16 53371 5 G 16 rm 19,7 - 23,8 768,0 1142,0 6
53366 5 G 1,5 re 9,1 - 11,0 72,0 177,0 16 53356 3 G 25 rm 20,4 - 24,6 720,0 1152,0 4
53374 7 G 1,5 re 9,9 - 11,9 101,0 209,0 16 53364 4 G 25 rm 22,6 - 27,3 960,0 1432,0 4
53351 3 G 2,5 re 8,7 - 10,6 72,0 163,0 14 53372 5 G 25 rm 24,7 - 29,8 1200,0 1800,0 4
53359 4 G 2,5 re 9,5 - 11,5 96,0 200,0 14 53357 3 G 35 rm 22,7 - 27,4 1008,0 1503,0 2
53367 5 G 2,5 re 10,4 - 12,3 120,0 238,0 14 53365 4 G 35 rm 24,9 - 30,0 1344,0 1930,0 2
53375 7 G 2,5 re 11,4 - 13,8 168,0 300,0 14 53373 5 G 35 rm 27,5 - 33,2 1680,0 2490,0 2

Dimensions and specifications may be changed without prior notice. (RO01)

521
TELEPHONE & FIRE WARNING CABLES

Designation Properties Approvals Page


Bd telephone outdoor cable, in accordance with VDE 0816,
A-2Y(L)2Y laminated sheath, unfilled
524

Bd telephone outdoor cable, in accordance with VDE 0816,


A-2YF(L)2Y laminated sheath filled, longitudinally water-tight
525

J-YY Bd Telephone indoor cable, in accordance with VDE 0815 526

J-Y(St)Y Lg Telephone indoor cable, in accordance with VDE 0815 527

J-Y(St)Y Lg Fire warning indoor cable 528

J-2Y(St)Y St III Bd 16 Mbits/s (Cat. 3) ISDN/EDV (Z=100 ohm), meter marking 529

S-YY Lg Patch cable in accordance with VDE 0813 530

J-H(St)H Bd installation cable, halogen-free, in accordance with VDE 0815 531

J-H(St)H Bd fire warning indoor cable, halogen-free 532

J-2Y(St)H St III Bd 16 Mbits/s (Cat.3) ISDN/EDV (Z = 100 ohm), halogen-free 533

523
Telephone and Fire Warning Cables

A-2Y(L)2Y Bd telephone-outdoor cable, according to DIN VDE 0816, laminated sheath,


unfilled

Technical data Cable structure Properties


acc. to DIN VDE 0816 Bare copper-conductor, single-wire These cables are not allowed for power
Temperature range Core insulation of PE (2Y) installation or applications requiring high
flexible -20C to +50C Core identification of quads marked with current levels. Due to their PE outer sheath,
fixed installation to +70C black rings these cables are also not permitted for fire
Loop resistance at 20C 4 cores twisted to a star quad and hazardous areas without any protective
0,6 mm = max. 130 Ohm/km 5 star quads stranded to sub units, measures.
0,8 mm = max. 73,2 Ohm/km each 5 or 10 sub units stranded to main Mutual capacitance at 800 Hz
Operating peak voltage max. 225 V units and the sub or main units stranded of all values100%
(not for purposes of high current and to cable core 0,6 mm - max. 52 nF/km
power installation) Core wrapping with several plastic tapes 0,8 mm - max. 55 nF/km
Test voltage Outer sheath, as laminated sheath (L)2Y, of all values 95%
core/core U eff. 5002) V PE-coated aluminium tape spliced with 0,6 mm - max. 503) nF/km
core/screen U eff. 2000 V PE (2Y) sheath 0,8 mm - max. 533) nF/km
Insulation resistance Sheath colour black of all values 80%
min. 5 GOhm x km Sheath marking continuously with 0,6 mm - max. 48 nF/km
Line attenuation telephone-receiver, meter marking 0,8 mm - max. 50 nF/km
of side circuits at 800 Hz in white colour Capacitance unbalances at 800 Hz
0,6 mm = 1,04 dB/km of all values k1 100% -max. 8001) pF/300 m
0,8 mm = 0,78 dB/km of all values k1 98% -max. 400 pF/300 m
Impedance of all values k9-12 100%-max.3001)pF/300 m
of side circuites at 800 Hz of all values k9-12 98% -max. 100 pF/300 m
0,6 mm = 720 Ohm
0,8 mm = 520 Ohm Note
Minimum bending radius But at least for 2 quads.
1)

10x cable Local cables with more than 100 pairs the
2)

Radiation resistance test conductor/conductor is emitted.


up to 80x106 cJ/kg (up to 80 Mrad) 3) For cables up to 10 double cores is the
Caloric load values 100 % value valid
see Technical Informations Conductor 0,4 mm on request.

Application
These external subscriber telephone cables are installed as telecommunication connection cable for connecting the telephone extension to the telephone
exchange or central offices and as well as for industrial plants. These subscriber connecting cables are suitable for laying in under ground, in cable
ducts and cable conduits - and also for indoor-laying. Both sides of PE-copolymere coated aluminium type (L), which is spliced with the outer PE-sheath
ensures a barrier against water vapour and diagonally water-proof. Black coloured PE-sheath is UV-resistant. The Polyethelene material
(PE 2Y) is halogen-free.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
34100 2 x 2 x 0,6 8,0 11,0 82,0 - 34130 2 x 2 x 0,8 11,0 20,0 102,0 -
34101 4 x 2 x 0,6 10,0 23,0 127,0 - 34131 4 x 2 x 0,8 12,0 40,0 158,0 -
34102 6 x 2 x 0,6 11,5 34,0 132,0 - 34132 6 x 2 x 0,8 13,0 60,0 179,0 -
34103 10 x 2 x 0,6 12,5 57,0 171,0 - 34133 10 x 2 x 0,8 14,5 101,0 241,0 -
34104 20 x 2 x 0,6 15,5 113,0 268,0 - 34134 20 x 2 x 0,8 18,0 201,0 393,0 -
34105 30 x 2 x 0,6 17,5 170,0 358,0 - 34135 30 x 2 x 0,8 21,0 302,0 540,0 -
34106 40 x 2 x 0,6 19,5 226,0 438,0 - 34136 40 x 2 x 0,8 23,0 402,0 675,0 -
34107 50 x 2 x 0,6 21,0 283,0 531,0 - 34137 50 x 2 x 0,8 25,5 503,0 842,0 -
34108 70 x 2 x 0,6 24,5 396,0 712,0 - 34138 70 x 2 x 0,8 29,0 704,0 1105,0 -
34109 100 x 2 x 0,6 28,0 565,0 950,0 - 34139 100 x 2 x 0,8 34,0 1005,0 1524,0 -
34110 150 x 2 x 0,6 33,0 848,0 1348,0 - 34140 150 x 2 x 0,8 40,0 1508,0 2208,0 -
34111 200 x 2 x 0,6 37,0 1131,0 1758,0 - 34141 200 x 2 x 0,8 46,5 2011,0 2915,0 -
34112 250 x 2 x 0,6 40,5 1414,0 2137,0 - 34142 250 x 2 x 0,8 51,0 2514,0 3575,0 -
34113 300 x 2 x 0,6 44,0 1696,0 2533,0 - 34143 300 x 2 x 0,8 53,0 3016,0 4232,0 -
34114 350 x 2 x 0,6 47,5 1979,0 2954,0 - 34144 350 x 2 x 0,8 56,5 3519,0 4940,0 -
34115 400 x 2 x 0,6 50,0 2262,0 3342,0 - 34145 400 x 2 x 0,8 60,0 4022,0 5565,0 -
34146 500 x 2 x 0,8 68,0 5027,0 6955,0 -
34147 600 x 2 x 0,8 73,0 6032,0 8240,0 -

Dimensions and specifications may be changed without prior notice. (RP01)

524
Telephone and Fire Warning Cables

A-2YF(L)2Y Bd telephone-outdoor cable, according to DIN VDE 0816, laminated


sheath, filled cable core, longitudinally water-proof

Technical data Cable structure Properties


acc. to DIN VDE 0816 Bare copper-conductor, single-wire These cables are not allowed for power
Temperature range Core insulation of PE (2Y) installation or applications requiring high
flexible -20C to +50C Core identification of quads marked with current levels. Due to their PE outer sheath,
fixed installation to +70C black rings these cables are also not permitted for fire
Loop resistance at 20C 4 cores twisted to a star quad and hazardous areas without any protective
0,6 mm = max. 130 Ohm/km 5 star quads stranded to sub units, measures.
0,8 mm = max. 73,2 Ohm/km each 5 or 10 sub units stranded to main Mutual capacitance at 800 Hz
Operating peak voltage max. 225 V units and the sub or main units stranded of all values100%
(not for purposes of high current and to cable core 0,6 mm - max. 52 nF/km
power installation) Core cavities continuously filled 0,8 mm - max. 55 nF/km
Test voltage with petrol-jelly of all values 95%
core/core U eff. 5002) V Core wrapping with paper tape 0,6 mm - max. 503) nF/km
core/screen U eff. 2000 V Outer sheath, as laminated sheath (L)2Y, 0,8 mm - max. 533) nF/km
Insulation resistance PE-coated aluminium tape spliced with of all values 80%
min. 1,5 GOhm x km PE (2Y) sheath 0,6 mm - max. 48 nF/km
Line attenuation Sheath colour black 0,8 mm - max. 50 nF/km
of side circuits at 800 Hz Sheath marking continuously with Capacitance unbalances at 800 Hz
0,6 mm = 1,04 dB/km telephone-receiver, meter marking of all values k1 100% -max. 8001) pF/300 m
0,8 mm = 0,78 dB/km in white colour of all values k1 98% -max. 400 pF/300 m
Impedance of side circuites of all values k9-12 100%-max.3001)pF/300 m
at 800 Hz of all values k9-12 98% -max. 100 pF/300 m
0,6 mm = 720 Ohm
0,8 mm = 520 Ohm Note
Minimum bending radius But at least for 2 quads.
1)

10x cable Local cables with more than 100 pairs the
2)

Radiation resistance test conductor/conductor is emitted.


up to 80x106 cJ/kg (up to 80 Mrad) 3) For cables up to 10 double cores is the
Caloric load values 100 % value valid
see Technical Informations Conductor 0,4 mm on request.

Application
These external subscriber telephone cables are installed as telecommunication connection cable for connecting the telephone extension to the telephone
exchange for transmitting signals. These subscriber connecting cables are suitable for laying in under ground, in cable ducts and cable conduits.
According to DIN VDE 0800 part 1, these cables are allowed in all types of installation plants. The cavities of the cable core, filled continuously with
viscous compound (F). Both sides of PE-copolymere coated aluminium type (L), which is spliced with the outer PE-sheath, ensures a barrier against
water vapour and crosswise and longitudinal water tightness. Black coloured PE-sheath is UV-resistant. The Polyethelene material (PE 2Y) P
is halogen-free.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
34007 2 x 2 x 0,6 7,5 11,0 80,0 - 34029 2 x 2 x 0,8 8,5 20,0 100,0 -
34008 4 x 2 x 0,6 9,0 23,0 140,0 - 34030 4 x 2 x 0,8 10,0 40,0 180,0 -
34009 6 x 2 x 0,6 12,0 34,0 150,0 - 34019 6 x 2 x 0,8 8,5 60,0 190,0 -
34010 10 x 2 x 0,6 13,5 57,0 190,0 - 34020 10 x 2 x 0,8 15,0 101,0 280,0 -
34011 20 x 2 x 0,6 16,0 113,0 310,0 - 34021 20 x 2 x 0,8 19,0 201,0 480,0 -
34012 30 x 2 x 0,6 19,0 170,0 430,0 - 34022 30 x 2 x 0,8 23,0 302,0 670,0 -
34013 40 x 2 x 0,6 20,5 226,0 545,0 - 34023 40 x 2 x 0,8 26,0 402,0 860,0 -
34014 50 x 2 x 0,6 23,0 283,0 660,0 - 34024 50 x 2 x 0,8 29,0 503,0 1060,0 -
34015 70 x 2 x 0,6 26,0 396,0 895,0 - 34025 70 x 2 x 0,8 33,0 704,0 1420,0 -
34016 100 x 2 x 0,6 31,5 565,0 1230,0 - 34026 100 x 2 x 0,8 39,0 1005,0 1980,0 -
34017 150 x 2 x 0,6 37,5 848,0 1780,0 - 34027 150 x 2 x 0,8 47,0 1508,0 2940,0 -
34018 200 x 2 x 0,6 42,5 1131,0 2320,0 - 34028 200 x 2 x 0,8 51,0 2011,0 3780,0 -
34036 250 x 2 x 0,6 47,5 1414,0 2910,0 - 34031 250 x 2 x 0,8 58,0 2514,0 4660,0 -
34037 300 x 2 x 0,6 51,5 1696,0 3490,0 - 34032 300 x 2 x 0,8 62,5 3016,0 5570,0 -
34038 350 x 2 x 0,6 55,0 1979,0 3970,0 - 34033 350 x 2 x 0,8 68,0 3519,0 6750,0 -
34039 400 x 2 x 0,6 60,5 2262,0 4480,0 - 34034 400 x 2 x 0,8 73,0 4022,0 7630,0 -
34040 500 x 2 x 0,6 66,0 2827,0 5460,0 - 34035 500 x 2 x 0,8 81,5 5027,0 9540,0 -

Dimensions and specifications may be changed without prior notice. (RP01)

525
Telephone and Fire Warning Cables

J-YY Bd telephone installation cable, according to DIN VDE 0815

Technical data Cable structure Properties


Installation cable acc. to DIN VDE 0815 Bare copper-conductor, single-wire PVC self-extinguishing and flame retardant
Temperature range Core insulation of PVC, acc. to DIN VDE 0482-332-1-2,
during operation -5C to +50C compound type YI1 DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation -30C to +70C to DIN VDE 0207 part 4 DIN VDE 0472 part 804 test method B)
Loop resistance Core and star quad identification to The materials used in manufacture are
at 20C max. 130 Ohm/km DIN VDE 0815 cadmium-free and contain no silicone
Operating peak voltage max. 300 V The cores to a quad and each 5 quads to a and free from substances harmful to
(not for purposes of high current and unit and several units are stranded in layer the wetting properties of lacquers
power installation) Foil wrapping
Test voltage (50 Hz) Outer sheath of PVC, flame retardant, Note
core/core U eff. 800 V compound type YM1 to This value may be extended by 20% with
1)

Insulation resistance DIN VDE 0207 part 5 a make-up to 4 pairs.


min. 100 MOhm x km Sheath colour grey 2) 20% of the values, but one value up to
Mutual capacitance 500 pF is allowed.
at 800 Hz max. 1001) nF/km 3) 10% of the values, but four values
Capacitance unbalances at 800 Hz (relationship) up to 300 pF are allowed.
k1 - max. 3002) pF/100 m
k9-12 - 1003) pF/100 m
Line attenuation
at 800 Hz 1,48 dB/km
Minimum bending radius
to DIN VDE 0891 part 5
during delivery 7,5x cable
single bending without tension
2,5x cable
repeated bending under tension
7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Caloric load values
see Technical Informations

Application
J-YY installation cables are preferably used as telephone cables in telephone stations and sub-extensions,in dry and damp premises, and in or under
plaster, in the open air for fixed installation. Telephone-Installation cables are not allowed for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
33100 2 x 2 x 0,6 4,5 11,0 34,0 - 33107 30 x 2 x 0,6 13,0 170,0 284,0 -
33101 4 x 2 x 0,6 6,5 23,0 59,0 - 33108 40 x 2 x 0,6 15,0 226,0 364,0 -
33102 6 x 2 x 0,6 7,0 34,0 74,0 - 33109 50 x 2 x 0,6 16,5 283,0 451,0 -
33103 10 x 2 x 0,6 8,5 57,0 111,0 - 33110 60 x 2 x 0,6 17,5 339,0 529,0 -
33104 16 x 2 x 0,6 10,0 90,0 160,0 - 33111 80 x 2 x 0,6 20,3 452,0 700,0 -
33105 20 x 2 x 0,6 11,0 113,0 200,0 - 33112 100 x 2 x 0,6 22,3 565,0 850,0 -
33106 24 x 2 x 0,6 11,5 136,0 224,0 -

Dimensions and specifications may be changed without prior notice. (RP01)

Suitable accessories can be found in Chapter X.


Core end sleeve - AV

526
Telephone and Fire Warning Cables

J-Y(St)Y Lg telephone installation cable, according to DIN VDE 0815

Technical data Cable structure Properties


Installation cable acc. to DIN VDE 0815 Bare copper-conductor, single-wire PVC self-extinguishing and flame retardant
Temperature range Core insulation of PVC, acc. to DIN VDE 0482-332-1-2,
during operation -5C to +50C compound type YI1 DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation -30C to +70C to DIN VDE 0207 part 4 DIN VDE 0472 part 804 test method B)
Loop resistance at 20C Core and pair identification The materials used in manufacture are
0,6 mm - max. 130 Ohm/km to DIN VDE 0815 cadmium-free and contain no silicone
0,8 mm - max. 73,2 Ohm/km Cores twisted to pairs and the pairs and free from substances harmful to
Operating peak voltage are stranded in layers the wetting properties of lacquers
(not for purposes of high current and Foil wrapping
power installation) Electrostatic screen (St) of plastic coated Note
0,6 mm - 300 V aluminium foil and drain wire This value may be extended by 20% with
1)

0,8 mm - 3003) V Outer sheath of PVC, flame retardant, a make-up to 4 pairs.


Test voltage compound type YM1 to 2) 20% of the values, but one value up to
core/core U eff. 800 V DIN VDE 0207 part 5 500 pF is allowed.
core/screen 800 V Sheath colour grey 3) Short time operation (6 s/min) up to
Insulation resistance 600 V permitted.
min. 100 MOhm x km 2-paired cables:
Mutual capacitance at 800 Hz cores are stranded to a star quad.
max. 1001) nF/km
Capacitance unbalances at 800 Hz
k- max. 3002) pF/100 m
Line attenuation at 800 Hz
0,6 mm - 1,7 dB/km
0,8 mm - 1,1 dB/km
Minimum bending radius
to DIN VDE 0891 part 5
during delivery 7,5x cable
single bending without tension
5x cable
repeated bending under tension
7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Caloric load values
see Technical Informations

Application
This cable type with electrostatic screening (St) protects the transmission circuits against extern electrical interferences. Installation cables laid up in
P
pairs are preferably used for telecommunications installations, in dry and damp premises, and in or under plaster, in the open air for fixed installation.
These cables are suitable for telephone stations and sub-extensions, for signal and data transmission. Telephone-Installation cables are not allowed
for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
33001 2 x 2 x 0,6 5,0 13,0 40,0 - 33018 2 x 2 x 0,8 7,0 21,0 60,0 -
33002 3 x 2 x 0,6 6,3 18,0 50,0 - 33019 3 x 2 x 0,8 8,5 31,0 80,0 -
33003 4 x 2 x 0,6 6,5 24,0 60,0 - 33020 4 x 2 x 0,8 9,0 41,0 100,0 -
33004 5 x 2 x 0,6 7,2 30,0 70,0 - 33021 5 x 2 x 0,8 9,5 52,0 120,0 -
33005 6 x 2 x 0,6 7,5 35,0 80,0 - 33022 6 x 2 x 0,8 11,0 62,0 140,0 -
33006 8 x 2 x 0,6 8,0 46,0 90,0 - 33023 8 x 2 x 0,8 11,5 82,0 170,0 -
33007 10 x 2 x 0,6 10,0 58,0 110,0 - 33024 10 x 2 x 0,8 13,2 102,0 220,0 -
33008 12 x 2 x 0,6 10,2 71,0 130,0 - 33025 12 x 2 x 0,8 14,2 123,0 250,0 -
33009 16 x 2 x 0,6 11,0 93,0 160,0 - 33026 16 x 2 x 0,8 16,0 164,0 320,0 -
33010 20 x 2 x 0,6 12,0 116,0 190,0 - 33027 20 x 2 x 0,8 17,0 204,0 380,0 -
33011 24 x 2 x 0,6 13,0 139,0 220,0 - 33028 24 x 2 x 0,8 19,0 244,0 460,0 -
33012 30 x 2 x 0,6 14,0 172,0 280,0 - 33029 30 x 2 x 0,8 20,8 304,0 560,0 -
33013 40 x 2 x 0,6 15,0 220,0 350,0 - 33030 40 x 2 x 0,8 23,0 405,0 710,0 -
33014 50 x 2 x 0,6 17,0 286,0 430,0 - 33031 50 x 2 x 0,8 26,0 505,0 900,0 -
33015 60 x 2 x 0,6 19,0 342,0 500,0 - 33032 60 x 2 x 0,8 28,0 606,0 1050,0 -
33016 80 x 2 x 0,6 21,0 455,0 640,0 - 33033 80 x 2 x 0,8 31,5 807,0 1400,0 -
33017 100 x 2 x 0,6 24,0 568,0 850,0 - 33034 100 x 2 x 0,8 33,0 1008,0 1750,0 -

Dimensions and specifications may be changed without prior notice. (RP01)

527
Telephone and Fire Warning Cables

J-Y(St)Y Lg fire warning installation cable

Technical data Cable structure Properties


Installation cable adapted to Bare copper-conductor, single-wire PVC self-extinguishing and flame retardant
DIN VDE 0815 Core insulation of PVC, acc. to DIN VDE 0482-332-1-2,
Temperature range compound type YI1 DIN EN 60332-1-2, IEC 60332-1 (equivalent
during operation -5C to +50C to DIN VDE 0207 part 4 DIN VDE 0472 part 804 test method B)
fixed installation -30C to +70C Core and pair identification to DIN VDE 0815 The materials used in manufacture are
Loop resistance Cores twisted in pairs Pairs stranded in layer cadmium-free and contain no silicone
at 20C max. 73,2 Ohm/km Foil wrapping and free from substances harmful to
Operating peak voltage 3003) V Plastic coated aluminium foil static the wetting properties of lacquers
(not for purposes of high current and screening (St)
power installation) Outer sheath of PVC, flame retardant, Note
Test voltage (50 Hz) compound type YM1 to This value may be extended by 20% with
1)

core/core U eff. 800 V DIN VDE 0207 part 5 a make-up to 4 pairs.


core/screen 800 V Sheath colour red, with imprint 2) 20% of the values, but one value up to
Insulation resistance "Brandmelde-Kabel" 500 pF is allowed.
min. 100 MOhm x km 3) Short time operation (6 s/min) up to
Mutual capacitance 600 V permitted.
at 800 Hz max. 1001) nF/km 2-paired cables:
Capacitance unbalances cores are stranded to a star quad.
at 800 Hz k - max. 3002) pF/100 m
Line attenuation
at 800 Hz 1,1 dB/km
Minimum bending radius
to DIN VDE 0891 part 5
during delivery 7,5x cable
single bending without tension
5x cable
repeated bending under tension
7,5x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)

Application
This cable type with electrostatic screening (St) protects the transmission circuits against extern electrical interferences. Installation cables laid up in
pairs are preferably used for telecommunication installation in dry and damp premises, and in or under plaster, in the open air for fixed installation.
These cables are suitable for telephone stations and sub-extensions, for signal and data transmission. Telephone-Installation cables are not allowed
for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
33035 1 x 2 x 0,8 4,5 11,0 38,0 - 33045 16 x 2 x 0,8 16,0 164,0 320,0 -
33036 2 x 2 x 0,8 7,0 21,0 60,0 - 33046 20 x 2 x 0,8 17,0 204,0 380,0 -
33037 3 x 2 x 0,8 8,5 31,0 80,0 - 33047 24 x 2 x 0,8 19,0 244,0 460,0 -
33038 4 x 2 x 0,8 9,0 41,0 100,0 - 33048 30 x 2 x 0,8 20,8 304,0 560,0 -
33039 5 x 2 x 0,8 9,5 52,0 120,0 - 33049 40 x 2 x 0,8 23,0 405,0 710,0 -
33040 6 x 2 x 0,8 11,0 62,0 140,0 - 33050 50 x 2 x 0,8 26,0 505,0 900,0 -
33041 8 x 2 x 0,8 11,5 82,0 170,0 - 33051 60 x 2 x 0,8 28,0 606,0 1050,0 -
33042 10 x 2 x 0,8 13,2 102,0 220,0 - 33052 80 x 2 x 0,8 31,5 807,0 1400,0 -
33043 12 x 2 x 0,8 14,2 123,0 250,0 - 33053 100 x 2 x 0,8 33,0 1008,0 1750,0 -
33044 14 x 2 x 0,8 14,6 145,0 280,0 -

Dimensions and specifications may be changed without prior notice. (RP01)

Suitable accessories can be found in Chapter X.


Core end sleeve - AV

528
Telephone and Fire Warning Cables

J-2Y(St)Y St III Bd 16 Mbits/s (Kat. 3) ISDN/EDV (Z = 100 Ohm), meter marking

Technical data Cable structure Properties


Special core insulation of PE adapted to Bare copper-conductor, single-wire PVC outer sheath: self-extinguishing and
DIN VDE 0815 and 0816 Core insulation of PE flame retardant to DIN VDE 0482-332-1-2,
Conductor loop-resistance Colour coding to DIN VDE 0815 DIN EN 60332-1-2/IEC 60332-1 (equivalent
max. 130 Ohm/km Conductors twisted to quads DIN VDE 0472 part 804 test method B)
Temperature range 5 quads twisted to units The materials used in manufacture are
flexing -5C to +70C Static screen of plastics coated alu foil with cadmium-free and contain no silicone
fixed installation -40C to +70C drain wire 0,6 mm and free from substances harmful to the
Operating peak voltage 300 V Outer sheath of PVC, flame retardant, wetting properties of lacquers
(not for heavy current installation purposes) compound type YM1 to
Test voltage 800 V DIN VDE 0207 part 5
Insulation resistance Sheath colour grey (RAL 7032)
min. 5 GOhm x km with meter marking
Mutual capacitance 48 nF/km
Characteristic impedance (Z)
at 4-16 MHz: 100 Ohm 15%
Capacitance unbalance
K1 max. 400 pF/300 m
K9-K12 max. 100 pF/300 m
Rel. velocity ratio
approx. 0,66
Attenuation at
1 MHz: 28 dB/km
4 MHz: 47 dB/km
5 MHz: 51 dB/km
10 MHz: 65 dB/km
15 MHz: 76 dB/km
16 MHz: 78 dB/km
20 MHz: 89 dB/km
Cross-talk attenuation
from 4 MHz up to 16 MHz
for 2 pairs: min. 40 dB
4 pairs and above: min. 25 dB
Minimum bending radius
stationary 10x cable

Application
Used as data transmission and connection cable suitable for fixed installation in and under plaster, for data transmission applications, for periphery
instrument data processing computers. Suitable for transmission of analog- and digital signals up to 16 Mbit/s. High cross-talk attentuation values.
P
Suitable as connecting cable for periphery equipment, data processing systems, monitors, printers and cash register systems. The static screen (St)
screen assures a disturbance-free data and signal transmission for measuring and control systems. These cables are not allowed for purposes of high
curren and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
33200 2 x 2 x 0,6 6,1 13,0 44,0 - 33206 30 x 2 x 0,6 14,0 172,0 302,0 -
33201 4 x 2 x 0,6 7,5 24,0 80,0 - 33207 40 x 2 x 0,6 15,5 229,0 376,0 -
33202 6 x 2 x 0,6 7,6 35,0 86,0 - 33208 50 x 2 x 0,6 17,3 266,0 480,0 -
33203 8 x 2 x 0,6 8,8 46,0 105,0 - 33209 60 x 2 x 0,6 18,1 342,0 560,0 -
33204 10 x 2 x 0,6 8,8 58,0 112,0 - 33210 80 x 2 x 0,6 22,0 455,0 748,0 -
33205 20 x 2 x 0,6 12,9 116,0 218,0 - 33211 100 x 2 x 0,6 25,2 588,0 940,0 -

Dimensions and specifications may be changed without prior notice. (RB01)

Suitable accessories can be found in Chapter X.


Core end sleeve - AV

529
Telephone and Fire Warning Cables

S-YY Lg switchboard cable according to DIN VDE 0813

Technical data Cable structure Properties


Switchboard cable acc. to DIN VDE 0813 Bare copper-conductor, single-wire PVC self-extinguishing and flame retardant
Temperature range Core insulation of PVC, acc. to DIN VDE 0482-332-1-2,
during operation -5C to +50C compound type YI1 DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation -30C to +70C to DIN VDE 0207 part 4 DIN VDE 0472 part 804 test method B)
Electrical characteristics Core identification to DIN VDE 0813 The materials used in manufacture are
acc. to VDE 0813 at 20C Cores stranded in layers cadmium-free and contain no silicone
Conductor resistance Foil wrapping and free from substances harmful to
0,5 mm - max. 96 Ohm/km Outer sheath of PVC, flame retardant, the wetting properties of lacquers
0,6 mm - max. 65 Ohm/km compound type YM1 to
1,0 mm - max. 23,4 Ohm/km DIN VDE 0207 part 5
Operating peak voltage Sheath colour grey (RAL 7032)
(not for purposes of high current and
power installation)
0,5 mm - max. 375 V
0,6 mm - max. 375 V
1,0 mm - max. 600 V
Test voltage core/core
0,5 mm - 2000 V
0,6 mm - 2500 V
1,0 mm - 2500 V
Insulation resistance
min. 100 MOhm x km
Min. permissible bending radius
acc. to DIN VDE 0891 part 3
during operation max. 7,5x cable

Application
In DIN VDE 0800 the operational areas are defined, where the application of switchboard cables permit. These are preferred for the transmission of
data signals of telecommunication and control processings i. e. in interlocking installations, to connect the outdoor cables with relay groups as well
as for fixed installation to interconnect the racks and distributor frames. This type is not allowed for the installation of heavy current operation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No. cores Outer Cop. Weight


x cond. approx. mm weight approx. kg / km
mm kg / km
34300 30 x 1 x 0,5 9,6 59,0 128,0 -
34301 60 x 1 x 0,5 11,9 118,0 233,0 -
34302 10 x 1 x 0,6 7,9 28,0 98,0 -
34303 20 x 1 x 0,6 9,6 57,0 132,0 -
34304 30 x 1 x 0,6 11,1 85,0 183,0 -
34305 60 x 1 x 0,6 15,4 170,0 344,0 -
34306 80 x 1 x 0,6 18,3 226,0 445,0 -
34307 20 x 1 x 1 14,5 157,0 292,0 -
34308 24 x 1 x 1 15,2 188,0 328,0 -
34309 32 x 1 x 1 16,3 251,0 430,0 -
34310 40 x 1 x 1 17,8 314,0 515,0 -
34311 60 x 1 x 1 22,2 471,0 710,0 -

Dimensions and specifications may be changed without prior notice. (RP01)

Suitable accessories can be found in Chapter X.


Core end sleeve - AV

530
Telephone and Fire Warning Cables

J-H(St)H Bd installation cable, halogen-free, according to DIN VDE 0816

Technical data Cable structure Properties


Flame retardant, halogen-free installation Bare copper-conductor, single-wire Not for purposes of high current and
cable acc. to DIN VDE 0815 Core insulation, halogen-free, power installation as well as underground
Temperature range compound type HI2 laying.
flexing -5C to +50C to DIN VDE 0207 part 23 The materials used in manufacture are
fixed installation -30C to +70C Core and star-quad identification to cadmium-free and contain no silicone
Loop resistance at 20C DIN VDE 0815 and free from substances harmful to
max. 130 Ohm/km at 0,6 mm Cores twisted in quads the wetting properties of lacquers
max. 73,2 Ohm/km at 0,8 mm The cores to quads and the quads are Tests
Operating peak voltage 300 V stranded to units Flame test acc. to DIN VDE 0482-332-3-24,
(not for purposes of high current Foil wrapping BS 4066 part 3, DIN EN 60332-3-24,
and power installation) Drain wire solid IEC 60332-3-24 (previously DIN VDE 0472
Test voltage Electrostatic screen (St) of plastic coated part 804 test method C)
core/core U eff. 800 V aluminium foil Corrosiveness of combustion gases
core/screen 800 V Outer sheath, halogen-free, flame retardant, acc. to DIN VDE 0482 part 267,
Insulation resistance compound type HM2 DIN EN 50267-2-2, IEC 60754-2
min. 100 MOhm x km to DIN VDE 0207 part 24 (equivalent DIN VDE 0472 part 813)
Mutual capacitance at 800 Hz Sheath colour grey Smoke density acc. to DIN VDE 0482
max. 1201) nF/km part 1034-1+2, DIN EN 61034-1+2,
Capacitance unbalances at 800 Hz IEC 61034-1+2, BS 7622 part 1+2
K1 max. 3002) pF/100 m (previously DIN VDE 0472 part 816)
K9-K12 max. 1003) pF/100 m
Line attenuation at 800 Hz Note
approx. 1,5 dB/km This value may be extended by 20% with
1)

Minimum bending radius make-up up to 4 pairs.


during delivery 7,5x cable 2) 20% of the values, but one value up to
single bending without tension 500 pF is allowed.
2,5x cable 3) 10% of the values, but four values
repeated bending under tension (relationship) up to 300 pF are allowed.
7,5x cable LS0H = Low Smoke Zero Halogen
Radiation resistance
up to 100x106 cJ/kg (up to 100 Mrad)
Caloric load values
see technical informations

Application
The halogen-free installation cables with improved characteristics in the case of fire are used for the telephone transmission, measurement and control
technology. The static screen protects the transmission circuits against outer electrical interferences. A fire propagation is prevented through high
oxygen index of the insulation material and produce no corrosive gases in case of fire. Those cables are preferably used for telecommunication
P
installations in dry and damp premises, and in or under plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
34050 2 x 2 x 0,6 5,4 14,0 50,0 - 34061 2 x 2 x 0,8 6,5 25,0 70,0 -
34051 4 x 2 x 0,6 7,3 25,0 91,0 - 34062 4 x 2 x 0,8 9,0 45,0 135,0 -
34052 6 x 2 x 0,6 7,7 37,0 100,0 - 34063 6 x 2 x 0,8 10,0 65,0 151,0 -
34053 10 x 2 x 0,6 9,1 59,0 147,0 - 34064 10 x 2 x 0,8 11,5 106,0 230,0 -
34054 20 x 2 x 0,6 13,5 116,0 308,0 - 34065 20 x 2 x 0,8 20,4 206,0 507,0 -
34055 30 x 2 x 0,6 15,1 172,0 350,0 - 34066 30 x 2 x 0,8 21,5 307,0 600,0 -
34056 40 x 2 x 0,6 16,5 229,0 465,0 - 34067 40 x 2 x 0,8 23,0 407,0 788,0 -
34057 50 x 2 x 0,6 18,6 286,0 571,0 - 34068 50 x 2 x 0,8 25,0 508,0 972,0 -
34058 60 x 2 x 0,6 19,3 342,0 662,0 - 34069 60 x 2 x 0,8 28,0 608,0 1120,0 -
34059 80 x 2 x 0,6 24,6 455,0 877,0 - 34070 80 x 2 x 0,8 31,5 809,0 1475,0 -
34060 100 x 2 x 0,6 27,2 568,0 1055,0 - 34071 100 x 2 x 0,8 32,3 1010,0 1804,0 -

Dimensions and specifications may be changed without prior notice. (RP01)

Suitable accessories can be found in Chapter X.


Core end sleeve - AV

531
Telephone and Fire Warning Cables

J-H(St)H Bd fire warning installation cable, halogen-free

Technical data Cable structure Properties


Flame retardant, halogen-free installation Bare copper-conductor, single-wire Not for purposes of high current and
cable adapted to DIN VDE 0815 Core insulation, halogen-free, power installation as well as underground
Temperature range compound type HI2 laying
flexing -5C to +50C to DIN VDE 0207 part 23 The materials used in manufacture are
fixed installation -30C to +70C Core and star-quad identification to cadmium-free and contain no silicone
Loop resistance at 20C DIN VDE 0815 and free from substances harmful to
max. 73,2 Ohm/km Cores twisted in quads the wetting properties of lacquers
Operating peak voltage 300 V The cores to quads and the quads are Tests
(not for purposes of high current stranded to units Flame test acc. to DIN VDE 0482-332-3-24,
and power installation) Foil wrapping BS 4066 part 3, DIN EN 60332-3-24,
Test voltage Drain wire solid IEC 60332-3-24 (previously DIN VDE 0472
core/core U eff. 800 V Electrostatic screen (St) of plastic coated part 804 test method C)
core/screen 800 V aluminium foil Corrosiveness of combustion gases
Insulation resistance Outer sheath, halogen-free, flame retardant, acc. to DIN VDE 0482 part 267,
min. 100 MOhm x km compound type HM2 DIN EN 50267-2-2, IEC 60754-2
Mutual capacitance at 800 Hz to DIN VDE 0207 part 24 (equivalent DIN VDE 0472 part 813)
max. 1201) nF/km Sheath colour red with imprint Smoke density acc. to DIN VDE 0482
Capacitance unbalances at 800 Hz "BRANDMELDEKABEL" part 1034-1+2, DIN EN 61034-1+2,
K1 max. 3002) pF/100 m IEC 61034-1+2, BS 7622 part 1+2
K9-K12 max. 1003) pF/100 m (previously DIN VDE 0472 part 816)
Line attenuation at 800 Hz
approx. 1,5 dB/km Note
Minimum bending radius This value may be extended by 20%
1)

during delivery 7,5x cable with make-up up to 4 pairs.


single bending without tension 2) 20% of the values, but one value up to
2,5x cable 500 pF is allowed.
repeated bending under tension 3) 10% of the values, but four values
7,5x cable (relationship) up to 300 pF are allowed.
Radiation resistance LS0H = Low Smoke Zero Halogen
up to 100x106 cJ/kg (up to 100 Mrad)
Caloric load values
see Technical Informations

Application
The halogen-free installation cables with improved characteristics in the case of fire are used for the telephone transmission, measurement and control
technology. The static screen protects the transmission circuits against outer electrical interferences. A fire propagation is prevented through high
oxygen index of the insulation material and produce no corrosive gases in case of fire. Those cables are preferably used for telecommunication
installations in dry and damp premises, and in or under plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
34116 2 x 2 x 0,8 6,8 25,0 70,0 - 34122 40 x 2 x 0,8 24,5 407,0 788,0 -
34117 4 x 2 x 0,8 10,5 45,0 135,0 - 34123 50 x 2 x 0,8 27,1 508,0 972,0 -
34118 6 x 2 x 0,8 10,9 65,0 151,0 - 34124 60 x 2 x 0,8 29,4 608,0 1120,0 -
34119 10 x 2 x 0,8 13,1 106,0 230,0 - 34125 80 x 2 x 0,8 33,2 809,0 1475,0 -
34120 20 x 2 x 0,8 20,4 206,0 507,0 - 34126 100 x 2 x 0,8 37,2 1010,0 1804,0 -
34121 30 x 2 x 0,8 21,5 307,0 600,0 -

Dimensions and specifications may be changed without prior notice. (RP01)

Suitable accessories can be found in Chapter X.


Core end sleeve - AV

532
Telephone and Fire Warning Cables

J-2Y(St)H St III Bd 16 Mbits/s (Kat.3) ISDN/EDV (Z = 100 Ohm), halogen-free

Technical data Cable structure Properties


Special core insulation of PE Bare copper-conductor, single-wire Outer sheath
adapted to DIN VDE 0815 and 0816 Core insulation of PE (2Y) Flame test acc. to
Conductor loop-resistance Colour coding to DIN VDE 0815 DIN VDE 0482-332-3, BS 4066 part 3,
max. 130 Ohm/km Conductors twisted to quads DIN EN 60332-3, IEC 60332-3 (previously
Temperature range 5 quads twisted to units DIN VDE 0472 part 804 test method C)
flexing -5C to +70C Static screen of plastics coated These cables are not allowed for purposes
fixed installation -30C to +70C alu foil with drain wire 0,6 mm of high current and power installation
Operating peak voltage 300 V Outer sheath, halogen-free, flame retardant, The materials used in manufacture are
(not for purposes of high current and polymer-compound cadmium-free and contain no silicone
power installation) Sheath colour grey and free from substances harmful to
Test voltage 800 V the wetting properties of lacquers
Insulation resistance
min. 5 GOhm x km
Mutual capacitance 48 nF/km
Characteristic impedance (Z)
at 4-16 MHz: 100 Ohm 15%
Capacitance unbalance
K1 max. 400 pF/300 m
K9-K12 max. 100 pF/300 m
Rel. velocity ratio approx. 0,66
Attenuation at
1 MHz: 28 dB/km
4 MHz: 47 dB/km
5 MHz: 51 dB/km
10 MHz: 65 dB/km
15 MHz: 76 dB/km
16 MHz: 78 dB/km
20 MHz: 89 dB/km
Cross-talk attenuation
from 4 MHz up to 16 MHz
for 2 pairs: min. 40 dB
4 pairs and above: min. 25 dB
Minimum bending radius
stationary 10x cable

Application
Used as data transmission and connection cable suitable for fixed installation in and under plaster, for data transmission applications, for periphery
instrument data processing computers. Suitable for transmission of analog- and digital signals up to 16 Mbit/s. High cross-talk attenuation values.
P
Suitable as connecting cable for periphery equipment, data processing systems, monitors, Printers and cash register systems. The static screen (St)
screen assures a disturbance-free data and signal transmission for measuring and control systems.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
34166 2 x 2 x 0,6 5,8 13,0 44,0 - 34172 30 x 2 x 0,6 15,0 172,0 302,0 -
34167 4 x 2 x 0,6 9,2 24,0 80,0 - 34173 40 x 2 x 0,6 16,8 229,0 376,0 -
34168 6 x 2 x 0,6 9,3 35,0 86,0 - 34174 50 x 2 x 0,6 18,5 266,0 480,0 -
34169 8 x 2 x 0,6 9,5 46,0 105,0 - 34175 60 x 2 x 0,6 20,2 342,0 560,0 -
34170 10 x 2 x 0,6 9,8 58,0 112,0 - 34176 80 x 2 x 0,6 23,0 455,0 748,0 -
34171 20 x 2 x 0,6 12,7 116,0 218,0 - 34177 100 x 2 x 0,6 25,2 588,0 940,0 -

Dimensions and specifications may be changed without prior notice. (RP01)

Suitable accessories can be found in Chapter X.


Core end sleeve - AV

533
POWER, SECURITY & MEDIUM VOLTAGE CABLES

Designation Properties Approvals Page

Underground cables & power distribution cables

NYY Underground cable 0.6/1 kV, VDE approved 538

NYCY Underground cable 0.6/1 kV, with concentric conductor VDE approved 540

NYCWY Underground cable 0.6/1 kV, with concentric conductor VDE approved 542

NAYY Underground cable 0.6/1 kV, VDE approved 544

NAY2Y Power cable 0.6/1 kV, with PE outer sheath 546

NAYCWY Underground cable 0.6/1 kV, with concentric conductor VDE approved 547

N2XY Underground cable 0.6/1 kV, VDE approved, increased current load 548

N2XCY Underground cable 0.6/1 kV, with concentric conductor, VDE approved, increased current load 549

NA2XY Underground cable 0.6/1 kV, VDE approved, increased current load 551

A-LiY(StE)Y Data transmission cable for gas stations and refineries with BAM certificate 552

Petrol station cable (N)YY-J 0.6/1 kV 553

NYKY-J 0.6/1 kV with lead sheath, VDE approval 554

Low-voltage & safety cables

N2HX Power cable 0.6/1 kV, halogen-free without functionality 557

N2XCH Power cable 0.6/1 kV, halogen-free, with concentric conductor, without functionality 559

(N)A2XH Power cable 0.6/1 kV, halogen-free without functionality 561

N2XH-FE 180/E 30 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 563

N2XCH-FE 180/E 30 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 565

(N)HXH-FE 180/E 30 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 567

(N)HXCH-FE 180/E 30 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 569

N2XH-FE 180/E 90 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 571

N2XCH-FE 180/E 90 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 573

(N)HXH-FE 180/E 90 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 575

(N)HXCH-FE 180/E 90 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 577

JE-H(St)H Bd FE 180/E 30 to E 90 (orange), halogen-free 579

JE-H(St)H Bd fire alarm cable, FE 180/E 30 to E 90 (red), halogen-free 580

JE-H(St)HRH Bd fire alarm cable, FE 180/E 30 to E 90, halogen-free 581 Q


Medium-voltage cables

N2XSY 6/10kV, 12/20kV, 18/30kV VPE-insulated Cu-conductor, single core, screened, PVC jacket 585

N2XS2Y 6/10kV, 12/20kV, 18/30kV VPE-insulated Cu-conductor, single core, screened, PE jacket 587

N2XS(F)2Y 6/10kV, 12/20kV, 18/30kV VPE-insulated Cu-conductor, single core, screened, longitudinally water-tight, PE jacket 589
VPE-insulated Cu-conductor, single core, screened, longitudinally and
N2XS(FL)2Y 6/10kV transversely water-tight PE jacket
591

NA2XSY 6/10kV, 12/20kV, 18/30kV VPE-insulated alu-conductor, single core, screened, PVC jacket 593

NA2XS2Y 6/10kV, 12/20kV, 18/30kV VPE-insulated Al-conductor, single core, screened, PE jacket 595

NA2XS(F)2Y 6/10kV, 12/20kV, 18/30kV VPE-insulated Al-conductor, single core, screened, longitudinally water-tight, PE jacket 597
VPE-insulated Al-conductor, single core, screened, longitudinally and
NA2XS(FL)2Y 6/10kV, 12/20kV, 18/30kV transversely water-tight PE jacket
599

NYFGY 3 x ... 3.6/6kV Ribbon cable armor, PVC jacket 601

N2XSEY 3 x 6/10kV VPE-insulated, screened, Cu-conductor, PVC jacket 602

N2XSEH 3x 6/10kV Power cable 0.6/1 kV, with PE outer sheath 603

535
CODE-DESIGNATION FOR POWER CABLES
WITH PVC OR XLPE INSULATION
Design Identification Explanations
of design

Core N According to VDE standard


(no abbreviation for copper conductor)

A Aluminium conductors

Y Insulation of thermoplastic
Polyvinylchloride (PVC)

2X Insulation cross-linked Polyethylene (XLPE)

Concentric conductor, C Concentric conductors of copper wires and copper


screen tape, helically wounded

CW Concentric conductor of copper wires in waveconal


formation and copper tape, helically wounded

CE Concentric conductor of copper wires and copper


tape over each individual core, helically wounded

Screen S Screen of copper wires and copper tape, helically


wounded

SE Screen of copper wires and copper tape over each


individual core, helically wounded

(F) Longitudinally water-proof screen

Armour B Armour of steel tape

F Armour of galvanized flat steel wires

G Counter helix of galvanized steel tape

Sheath K Lead sheath

Outer sheath Y PVC sheath

2Y PE sheath

Cable for U0/U 0,6/1 kV are additionally designated with

J Cables with green-yellow (green-natural) core are


marked with protective conductor

O able without green-yellow (green-natural) core are


marked without protective conductor

536
UNDERGROUND CABLES & POWER DISTRIBUTION CABLES
Energy- and Power Cable / Power Cables / Power cables for energy supply

NYY power cable, 0,6/1kV, VDE approved

Technical data Cable structure Properties


Power and control cable to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0276 part 603, DIN VDE 0295 cl.1 or cl.2, single-wire cadmium-free and contain no silicone
HD 603 S1 and IEC 60502, or multi-wire, BS 6360 cl.1 or cl.2, and free from substances harmful to
7 core and above to DIN VDE 0276 IEC 60228 cl.1 or cl.2 the wetting properties of lacquers
part 627, HD 627 S1 and IEC 60502 Core insulation of PVC Tests
Temperature range compound type DIV4 PVC self-extinguishing and flame retardant
flexing -5C to +50C to HD 603 S1 acc. to DIN VDE 0482-332-1-2,
fixed installation -40C to +70C Core identification to DIN EN 60332-1-2, IEC 60332-1 (equivalent
Permissible operating temperature DIN VDE 0293-308, 0276 part 603 DIN VDE 0472 part 804 test method B)
at conductor +70C Core colour for 3+ conductor Highest permissible voltage
Permissible short circuit temperature J-version: GN-YE (), BN, BK, GY Direct current systems 1,8 kV
(short circuit duration max. 5 s) O-version: BU (), BN, BK, GY Alternating current systems
300 mm +160C Cores stranded in concentric layers Single-phase systems
> 300 mm +140C Outer sheath of PVC both outer conductors insulated 1,4 kV
Nominal voltage U0/U 0,6/1 kV compound type DMV5 Single-phase systems
Test voltage 4 kV to HD 603 S1 one outer conductor earthed 0,7 kV
Max. permissible tensile stress Sheath colour black Three-phase systems 1,2 kV
with cable grip at conductor
50 N/mm Note
Minimum bending radius re = round conductor, single-wire
single-core 15x cable rm = round conductor, multi-wire
multi-core 12x cable sm = sectional conductor, mutli-wire
Caloric load values J-version = with GN-YE conductor
see Technical Informations O-version = without GN-YE conductor
In respect to 3+ conductors
Whereby only one conductor is allowed to
contain a smaller cross-section (as per
DIN VDE 0276 part 603 table 5) and
permitted to place as insulated core
(gree-yellow and blue as -conductor),
stranded in layer.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Power cables for energy supply are installed in open air, in underground, in water, in concrete, indoors, in cable ducts, power stations, for industry
and distribution boards as well as in subscriber networks, where mechanical damages are not to be expected.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

No.cores x Outer Cop. Weight J type AWG-No. O type AWG-No.


cross-sec. app. mm weight app. kg / km Part no. Part no.
mm kg / km
1x4 re 9,0 38,0 115,0 32001 12 - 32089 12 -
1x6 re 9,5 58,0 135,0 32002 10 - 32090 10 -
1 x 10 re 10,0 96,0 179,0 32003 8 - 32091 8 -
1 x 16 re 11,0 154,0 245,0 32004 6 - 32092 6 -
1 x 25 rm 12,0 240,0 360,0 32005 4 - 32093 4 -
1 x 35 rm 13,0 336,0 470,0 32006 2 - 32094 2 -
1 x 50 rm 15,0 480,0 620,0 32007 1 - 32095 1 -
1 x 70 rm 16,5 672,0 810,0 32008 2/0 - 32096 2/0 -
1 x 95 rm 19,0 912,0 1110,0 32009 3/0 - 32097 3/0 -
1 x 120 rm 20,5 1152,0 1360,0 32010 4/0 - 32098 4/0 -
1 x 150 rm 22,5 1440,0 1670,0 32011 300 kcmil - 32099 300 kcmil -
1 x 185 rm 25,0 1776,0 2050,0 32012 350 kcmil - 32100 350 kcmil -
1 x 240 rm 28,0 2304,0 2630,0 32013 500 kcmil - 32101 500 kcmil -
1 x 300 rm 30,0 2880,0 3200,0 32014 600 kcmil - 32102 600 kcmil -
1 x 400 rm 34,0 3840,0 4150,0 32015 750 kcmil - 32103 750 kcmil -
1 x 500 rm 38,0 4800,0 5200,0 32556 1000 kcmil - 32558 1000 kcmil -
1 x 630 rm 43,0 6048,0 6650,0 32557 1250 kcmil - 32559 1250 kcmil -

Continuation

538
Energy- and Power Cable / Power Cables / Power cables for energy supply

NYY power cable, 0,6/1kV, VDE approved


No.cores x Outer Cop. Weight J type AWG-No. O type AWG-No.
cross-sec. app. mm weight app. kg / km Part no. Part no.
mm kg / km
2 x 1,5 re 11,0 29,0 175,0 32016 16 - 32104 16 -
2 x 2,5 re 12,0 48,0 215,0 32017 14 - 32105 14 -
2x4 re 14,0 77,0 295,0 32018 12 - 32106 12 -
2x6 re 15,0 115,0 370,0 32019 10 - 32107 10 -
2 x 10 re 16,5 192,0 495,0 32020 8 - 32108 8 -
2 x 16 re 18,5 307,0 670,0 32021 6 - 32109 6 -
2 x 25 rm 23,5 480,0 960,0 32022 4 - 32110 4 -
3 x 1,5 re 11,5 43,0 195,0 32023 16 - 32111 16 -
3 x 2,5 re 12,5 72,0 250,0 32024 14 - 32112 14 -
3x4 re 14,0 115,0 340,0 32025 12 - 32113 12 -
3x6 re 15,0 173,0 430,0 32026 10 - 32114 10 -
3 x 10 re 17,0 288,0 590,0 32027 8 - 32115 8 -
3 x 16 re 19,0 461,0 820,0 32028 6 - 32116 6 -
3 x 25 rm 24,0 720,0 1320,0 32029 4 - 32117 4 -
3 x 35 sm 25,0 1008,0 1450,0 32030 2 - 32118 2 -
3 x 50 sm 26,5 1440,0 1850,0 32031 1 - 32119 1 -
3 x 70 sm 30,0 2016,0 2450,0 32032 2/0 - 32120 2/0 -
3 x 95 sm 34,5 2736,0 3300,0 32033 3/0 - 32121 3/0 -
3 x 120 sm 37,0 3456,0 4100,0 32034 4/0 - 32122 4/0 -
3 x 150 sm 40,0 4320,0 4900,0 32293 300 kcmil - 32296 300 kcmil -
3 x 185 sm 46,0 5328,0 6500,0 32294 350 kcmil - 32297 350 kcmil -
3 x 240 sm 51,0 6912,0 8300,0 32295 500 kcmil - 32298 500 kcmil -
4 x 1,5 re 12,0 58,0 230,0 32044 16 - 32132 16 -
4 x 2,5 re 13,5 96,0 300,0 32045 14 - 32133 14 -
4x4 re 15,0 154,0 410,0 32046 12 - 32134 12 -
4x6 re 16,5 230,0 520,0 32047 10 - 32135 10 -
4 x 10 re 18,5 384,0 730,0 32048 8 - 32136 8 -
4 x 16 re 21,5 614,0 1045,0 32049 6 - 32137 6 -
4 x 25 rm 26,0 960,0 1640,0 32050 4 - 32138 4 -
4 x 35 sm 27,5 1344,0 1760,0 32051 2 - 32139 2 -
4 x 50 sm 30,0 1920,0 2350,0 32052 1 - 32140 1 -
4 x 70 sm 34,0 2688,0 3100,0 32053 2/0 - 32141 2/0 -
4 x 95 sm 39,0 3648,0 4250,0 32054 3/0 - 32142 3/0 -
4 x 120 sm 42,5 4608,0 5300,0 32055 4/0 - 32143 4/0 -
4 x 150 sm 47,5 5760,0 6400,0 32056 300 kcmil - 32144 300 kcmil -
4 x 185 sm 52,0 7104,0 8500,0 32057 350 kcmil - 32145 350 kcmil -
4 x 240 sm 58,0 9216,0 11000,0 32058 500 kcmil - 32146 500 kcmil -
5 x 1,5 re 13,0 72,0 270,0 32059 16 - 32147 16 -
5 x 2,5 re 14,5 120,0 360,0 32060 14 - 32148 14 -
5x4 re 16,5 192,0 490,0 32061 12 - 32149 12 -
5x6 re 18,0 288,0 600,0 32062 10 - 32150 10 -
5 x 10 re 20,0 480,0 890,0 32063 8 - 32151 8 -
5 x 16 re 22,5 768,0 1255,0 32064 6 - 32152 6 -
5 x 25 rm 28,0 1200,0 1960,0 32065 4 -
5 x 35 rm 34,0 1680,0 2400,0 32300 2 -
5 x 50 rm 40,0 2400,0 3500,0 32257 1 -
5 x 70 rm 42,7 3360,0 4470,0 79608 2/0 -
5 x 95 rm 50,3 4560,0 6149,0 700939 3/0 -
7 x 1,5 re 15,5 101,0 310,0 32066 16 - 32153 16 -
7 x 2,5 re 16,5 168,0 450,0 32076 14 - 32163 10 -
7x4 re 18,5 269,0 640,0 32086 12 - 32173 12 -
7x6 re 20,0 403,0 850,0 32087 10 - 32174 10 -
7 x 10 re 23,5 672,0 1200,0 32088 8 - 32175 8 -
10 x 1,5 re 18,0 144,0 380,0 32067 16 - 32154 16 -
10 x 2,5 re 19,5 240,0 520,0 32077 14 - 32164 10 -
12 x 1,5 re 19,0 173,0 420,0 32068 16 - 32155 16 -
12 x 2,5 re 20,5 288,0 600,0 32078 14 - 32165 14 -
14 x 1,5 re 20,0 202,0 470,0 32069 16 - 32156 16 -
14 x 2,5 re 21,0 336,0 680,0 32079 14 - 32166 14 -
16 x 1,5 re 21,0 230,0 520,0 32070 16 - 32157 16 -
16 x 2,5 re 22,0 384,0 750,0 32080 14 - 32167 14 -
19 x 1,5 re 22,0 274,0 570,0 32071 16 - 32158 16 -
19 x 2,5 re 23,0 456,0 850,0 32081 14 - 32168 14 -
21 x 1,5 re 23,0 302,0 650,0 32072 16 - 32159 16 -
21 x 2,5
24 x 1,5
re
re
24,5
25,0
504,0
346,0
980,0
750,0
32082
32073
14
16
-
- 32160 16 - Q
24 x 2,5 re 27,0 576,0 1100,0 32083 14 - 32170 14 -
30 x 1,5 re 26,0 432,0 860,0 32074 16 - 32161 16 -
30 x 2,5 re 28,0 720,0 1280,0 32084 14 - 32171 14 -
40 x 1,5 re 29,0 576,0 1070,0 32075 16 - 32162 16 -
40 x 2,5 re 31,5 960,0 1700,0 32085 14 - 32172 14 -
52 x 2,5 re 35,0 1248,0 2150,0 32169 14 -
61 x 1,5 re 34,0 878,0 1680,0 32176 16 -

3+1/2-conductors
No.cores x Outer Cop. Weight J type AWG-No. O type AWG-No.
cross-sec. app. mm weight app. kg / km Part no. Part no.
mm kg / km
3 x 25 / 16 rm/re 24,5 874,0 1530,0 32035 4 - 32123 4 -
3 x 35 / 16 sm/re 26,0 1162,0 1750,0 32036 2 - 32124 2 -
3 x 50 / 25 sm 29,0 1680,0 2350,0 32037 1 - 32125 1 -
3 x 70 / 35 sm/rm 32,0 2352,0 2850,0 32038 2/0 - 32126 2/0 -
3 x 95 / 50 sm 38,0 3216,0 3850,0 32039 3/0 - 32127 3/0 -
3 x 120 / 70 sm 41,0 4128,0 4780,0 32040 4/0 - 32128 4/0 -
3 x 150 / 70 sm 46,0 4992,0 5800,0 32041 300 kcmil - 32129 300 kcmil -
3 x 185 / 95 sm 51,0 6240,0 7600,0 32042 350 kcmil - 32130 350 kcmil -
3 x 240 / 120 sm 58,0 8064,0 9800,0 32043 500 kcmil - 32131 500 kcmil -
3 x 300 / 150 sm 64,0 10080,0 11500,0 32256 600 kcmil -

Dimensions and specifications may be changed without prior notice. (RQ01)

539
Energy- and Power Cable / Power Cables / Power cables for energy supply

NYCY power cable, 0,6/1kV, VDE approved, with concentric copper conductor

Technical data Cable structure Properties


Power and control cable to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0276 part 603, DIN VDE 0295 cl.1, single-wire, cadmium-free and contain no silicone
HD 603 S1 and IEC 60502 BS 6360 cl.1, IEC 60228 cl.1 and free from substances harmful to
7 cores and above to DIN VDE 0276 Core insulation of PVC the wetting properties of lacquers
part 627, HD 627 S1 and IEC 60502 compound type DIV4 to HD 603 S1 Tests
Temperature range Core identification to DIN VDE 0293-308 PVC self-extinguishing and flame retardant
flexing -5C to +50C Cores stranded in concentric layers acc. to DIN VDE 0482-332-1-2,
fixed installation -40C to +70C Filling compound DIN EN 60332-1-2, IEC 60332-1 (equivalent
Permissible operating temperature Concentric conductor in inner layer of DIN VDE 0472 part 804 test method B)
at conductor +70C round copper wires, outer layer with Highest permissible voltage
Permissible short circuit temperature copper tape Direct current systems 1,8 kV
(short circuit duration max. 5 s) Outer sheath of PVC Alternating current systems
+160C compound type DMV5 to HD 603 S1 Single-phase systems 1,4 kV
Nominal voltage U0/U 0,6/1 kV Sheath colour black both outer conductors insulated
Test voltage 4 kV Single-phase systems 0,7 kV
Max. permissible tensile stress one outer conductor earthed
with cable grip at conductor Three-phase systems 1,2 kV
50 N/mm with concentric conductor and
Minimum bending radius a cross-section of 240 mm
single-core 15x cable and above 3,6 kV
multi-core 12x cable
Caloric load values Note
see Technical Informations re = round conductor, single-wire
Available with outer sheath in alternative
colours on request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Power cables for energy supply are used for industry and distribution boards, power stations, house connecting boxes and street lighting as well as
control cable for the transmission of control impulses and test datas. Overall, where increased electrical and also mechanical protection are required.
Those cables are installed in open air, in underground, in water, in concrete, indoors and in cable ducts. The concentric conductor (C) is allowed to
use as PE-, PEN-conductor or as screen.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No.


cross-sec. app. mm weight app. kg / km
mm kg / km
32200 1 x 10 re / 10 11,0 216,0 280,0 8
32201 1 x 16 re / 16 12,0 336,0 440,0 6
32202 2 x 1,5 re / 1,5 13,0 52,0 205,0 16
32203 2 x 2,5 re / 2,5 13,5 80,0 270,0 14
32204 2x4 re / 4 15,5 123,0 360,0 12
32205 2x6 re / 6 17,0 182,0 435,0 10
32206 2 x 10 re / 10 19,5 312,0 590,0 8
32207 2 x 16 re / 16 20,5 489,0 820,0 6
32208 3 x 1,5 re / 1,5 13,5 66,0 225,0 16
32209 3 x 2,5 re / 2,5 14,5 104,0 290,0 14
32210 3x4 re / 4 16,5 161,0 400,0 12
32211 3x6 re / 6 17,5 240,0 510,0 10
32212 3 x 10 re / 10 20,0 408,0 850,0 8
32213 3 x 16 re / 16 23,0 643,0 1080,0 6
32214 4 x 1,5 re / 1,5 14,5 81,0 260,0 16
32215 4 x 2,5 re / 2,5 15,5 128,0 350,0 14
32216 4x4 re / 4 17,0 200,0 470,0 12
32217 4x6 re / 6 18,5 297,0 590,0 10
32218 4 x 10 re / 10 21,0 504,0 900,0 8
32219 4 x 16 re / 16 23,0 796,0 1250,0 6
32220 5 x 1,5 re / 1,5 15,0 95,0 330,0 16
32221 5 x 2,5 re / 2,5 16,0 152,0 400,0 14
32222 5x4 re / 4 19,0 238,0 560,0 12
32223 5x6 re / 6 21,0 355,0 710,0 10

Continuation

540
Energy- and Power Cable / Power Cables / Power cables for energy supply

NYCY power cable, 0,6/1kV, VDE approved, with concentric copper conductor
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km
mm kg / km
32224 5 x 10 re / 10 23,0 600,0 1000,0 8
32226 7 x 1,5 re / 1,5 16,0 124,0 320,0 16
32227 7 x 1,5 re / 2,5 16,0 133,0 350,0 16
32241 7 x 2,5 re / 2,5 17,5 200,0 450,0 14
32225 7x4 re / 4 21,0 315,0 670,0 12
32255 7x6 re / 6 24,0 470,0 790,0 10
32228 8 x 1,5 re / 1,5 17,0 138,0 380,0 16
32229 8 x 1,5 re / 2,5 17,0 147,0 400,0 16
32242 8 x 2,5 re / 2,5 18,0 224,0 510,0 14
32230 10 x 1,5 re / 2,5 19,0 176,0 440,0 16
32243 10 x 2,5 re / 4 20,5 286,0 600,0 14
32231 12 x 1,5 re / 2,5 20,0 205,0 500,0 16
32244 12 x 2,5 re / 4 21,0 334,0 660,0 14
32232 14 x 1,5 re / 2,5 20,5 234,0 540,0 16
32245 14 x 2,5 re / 4 22,0 382,0 760,0 14
32246 14 x 2,5 re / 6 22,5 403,0 800,0 14
32233 16 x 1,5 re / 4 22,0 276,0 600,0 16
32247 16 x 2,5 re / 6 23,0 451,0 910,0 14
32234 19 x 1,5 re / 4 23,0 320,0 690,0 16
32248 19 x 2,5 re / 6 23,5 523,0 950,0 14
32235 21 x 1,5 re / 6 24,0 369,0 810,0 16
32249 21 x 2,5 re / 10 26,0 571,0 1100,0 14
32236 24 x 1,5 re / 6 26,0 413,0 860,0 16
32250 24 x 2,5 re / 10 28,0 696,0 1300,0 14
32237 30 x 1,5 re / 6 27,0 499,0 1230,0 16
32251 30 x 2,5 re / 10 30,0 840,0 1610,0 14
32238 40 x 1,5 re / 10 30,0 696,0 1590,0 16
32252 40 x 2,5 re / 10 35,0 1080,0 2100,0 14
32239 52 x 1,5 re / 10 32,0 869,0 1820,0 16
32253 52 x 2,5 re / 10 38,0 1368,0 2500,0 14
32240 61 x 1,5 re / 10 33,0 998,0 2000,0 16
32254 61 x 2,5 re / 10 40,0 1584,0 2850,0 14

Dimensions and specifications may be changed without prior notice. (RQ01)

Suitable accessories can be found in Chapter X.


Cable lug - copper
Cable lug - aluminium

541
Energy- and Power Cable / Power Cables / Power cables for energy supply

NYCWY power cable, 0,6/1kV, with concentric copper conductor, VDE approved

Technical data Cable structure Properties


Power and control cable to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0276 part 603, DIN VDE 0295 cl.1 or cl.2, single-wire cadmium-free and contain no silicone
HD 603 S1 and IEC 60502 or multi-wire, BS 6360 cl.1 or cl.2, and free from substances harmful to
Temperature range IEC 60228 cl.1 or cl.2 the wetting properties of lacquers
flexing -5C to +50C Core insulation of PVC Tests
fixed installation -40C to +70C compound type DIV4 to HD 603 S1 PVC self-extinguishing and flame retardant
Permissible operating temperature Core identification to DIN VDE 0293-308 acc. to DIN VDE 0482-332-1-2,
at conductor +70C Cores concentrically stranded DIN EN 60332-1-2, IEC 60332-1 (equivalent
Permissible short circuit temperature Filling compound DIN VDE 0472 part 804 test method B)
(short circuit duration max. 5 s) Concentric conductor (Ceander), Highest permissible voltage
+160C inner layer of corrugated copper wires, Direct current systems 1,8 kV
Nominal voltage U0/U 0,6/1 kV outer layer with copper tape Alternating current systems
Test voltage 4 kV Outer sheath of PVC Single-phase systems
Max. permissible tensile stress compound type DMV5 to HD 603 S1 both outer conductors insulated 1,4 kV
with cable grip at conductor Sheath colour black Single-phase systems
50 N/mm one outer conductor earthed 0,7 kV
Minimum bending radius Three-phase systems 1,2 kV
12x cable with concentric conductor and
Power ratings table a cross-section of 240 mm
see Technical Informations and above 3,6 kV
Caloric load values
see Technical Informations Note
re = round conductor, single-wire
rm = round conductor, multi-wire
sm = sectional conductor, multi-wire
Available with outer sheath in alternative
colours on request
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Power cables for energy supply are used for industry and distribution boards, power stations, house connecting boxes and street lighting as well as
control cable for the transmission of control impulses and test datas. Overall, where increased electrical and also mechanical protection are required.
Those cables are installed in open air, in underground, in water, in concrete, indoors and in cable ducts. The concentric conductor (C) is allowed to
use as PE-, PEN-conductor or as screen. The corrugated design (Ceander) of the concentric conductor permits any number of cable junctions during
assembly, without any conductors having to be cut. This ensures a optimal reliability.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No.


cross-sec. app. mm weight app. kg / km
mm kg / km
32260 2 x 10 re / 10 19,0 312,0 650,0 8
32261 2 x 16 re / 16 21,0 489,0 850,0 6
32262 2 x 25 rm / 25 24,0 763,0 1210,0 4
32263 3 x 10 re / 10 19,5 408,0 730,0 8
32264 3 x 16 re / 16 22,0 643,0 1000,0 6
32265 3 x 25 rm / 16 26,0 902,0 1550,0 4
32274 3 x 25 rm / 25 26,0 1003,0 1600,0 4
32266 3 x 35 sm / 16 27,0 1190,0 1750,0 2
32275 3 x 35 sm / 35 27,5 1402,0 1850,0 2
32267 3 x 50 sm / 25 29,5 1723,0 2250,0 1
32276 3 x 50 sm / 50 29,5 2000,0 2450,0 1
32268 3 x 70 sm / 35 33,0 2410,0 2950,0 2/0
32277 3 x 70 sm / 70 34,0 2796,0 3350,0 2/0
32269 3 x 95 sm / 50 38,0 3296,0 4100,0 3/0
32278 3 x 95 sm / 95 38,5 3791,0 4550,0 3/0
32270 3 x 120 sm / 70 41,0 4236,0 5050,0 4/0
32279 3 x 120 sm / 120 42,0 4786,0 5550,0 4/0
32271 3 x 150 sm / 70 45,0 5100,0 6000,0 300 kcmil
32280 3 x 150 sm / 150 46,0 5970,0 6900,0 300 kcmil
32272 3 x 185 sm / 95 50,0 6383,0 7550,0 350 kcmil
32281 3 x 185 sm / 185 51,0 7363,0 8500,0 350 kcmil
32273 3 x 240 sm / 120 57,0 8242,0 9950,0 500 kcmil
32282 4 x 10 re / 10 20,5 504,0 890,0 8
32283 4 x 16 re / 16 23,5 796,0 1250,0 6

Continuation

542
Energy- and Power Cable / Power Cables / Power cables for energy supply

NYCWY power cable, 0,6/1kV, with concentric copper conductor, VDE approved
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km
mm kg / km
32284 4 x 25 rm / 16 28,0 1142,0 1800,0 4
32285 4 x 35 sm / 16 29,0 1526,0 2050,0 2
32286 4 x 50 sm / 25 33,0 2203,0 2700,0 1
32287 4 x 70 sm / 35 37,0 3082,0 3750,0 2/0
32288 4 x 95 sm / 50 43,5 4208,0 5000,0 3/0
32289 4 x 120 sm / 70 47,0 5388,0 6350,0 4/0
32290 4 x 150 sm / 70 51,0 6540,0 7650,0 300 kcmil
32291 4 x 185 sm / 95 56,0 8159,0 9350,0 350 kcmil
32292 4 x 240 sm / 120 62,5 10546,0 11600,0 500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ01)

3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP

543
Energy- and Power Cable / Power Cables / Power cables for energy supply

NAYY power cable, 0,6/1 kV, VDE approved

Technical data Cable structure Properties


Power and control cable to Aluminium-conductor, to DIN VDE 0295 The materials used in manufacture are
DIN VDE 0276 part 603, cl.1 or cl.2, single-wire or multi-wire, cadmium-free and contain no silicone
HD 603 S1 and IEC 60502 BS 6360 cl.1 or cl.2, IEC 60228 and free from substances harmful to
Insulation and sheath-compound of cl.1 or cl.2 the wetting properties of lacquers
thermoplastic PVC Core insulation of PVC Tests
Temperature range compound type DIV4 PVC self-extinguishing and flame retardant
flexing -5C to +50C to HD 603 S1 acc. to DIN VDE 0482-332-1-2,
fixed installation -40C to +70C Core identification to DIN EN 60332-1-2, IEC 60332-1 (equivalent
Permissible operating temperature DIN VDE 0293-308, 0276 part 603 DIN VDE 0472 part 804 test method B)
at conductor +70C Cores stranded in concentric layers Highest permissible voltage
Permissible short circuit temperature Common core sheath Direct current systems 1,8 kV
(short circuit duration max. 5 s) Outer sheath of PVC Alternating current systems
300 mm +160C compound type DMV5 Single-phase systems
> 300 mm +140C to HD 603 S1 both outer conductors insulated 1,4 kV
Nominal voltage U0/U 0,6/1 kV Sheath colour black Single-phase systems
Test voltage 4 kV one outer conductor earthed 0,7 kV
Max. permissible tensile stress Three-phase systems 1,2 kV
with cable grip at conductor
30 N/mm Note
Current carrying capacity re = round conductor, single-wire
to DIN VDE 0276 part 603, rm = round conductor, multi-wire
in normal operation table 14 and 15, se = sectional conductor, single-wire
under short circuit conditions table 17 sm = sectional conductor, mutli-wire
Minimum bending radius J-version = with GN-YE conductor
single-core 15x cable O-version = without GN-YE conductor
multi-core 12x cable AWG sizes are approximate equivalent
Caloric load values values. The actual cross-section is in mm.
see Technical Informations

Application
Power cables for energy supply are installed in open air, in underground, in water, in concrete, indoors, in cable ducts, power stations, for industry
and distribution boards as well as in subscriber networks, where mechanical damages are not be expected.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

No.cores x Outer Alu weight Weight J type AWG-No. O type AWG-No.


cross-sec. app. mm kg / km app. kg / km Part no. Part no.
mm
4 x 16 re 23,0 186,0 750,0 32301 6 - 32184 6 -
4 x 25 re 26,0 290,0 950,0 32302 4 - 32185 4 -
4 x 35 re 28,5 406,0 1120,0 32303 2 - 32186 2 -
4 x 50 se 30,0 580,0 1151,0 32304 1 - 32187 1 -
4 x 70 se 35,0 812,0 1549,0 32305 2/0 - 32188 2/0 -
4 x 95 se 39,5 1102,0 2030,0 32306 3/0 - 32189 3/0 -
4 x 95 sm 39,5 1102,0 2030,0 32177 3/0 - 32190 3/0 -
4 x 120 se 44,0 1392,0 2400,0 32307 4/0 - 32191 4/0 -
4 x 120 sm 44,0 1392,0 2400,0 32178 4/0 - 32192 4/0 -
4 x 150 se 46,0 1740,0 3030,0 32308 300 kcmil - 32193 300 kcmil -
4 x 150 sm 46,0 1740,0 3030,0 32179 300 kcmil - 32194 300 kcmil -
4 x 185 se 51,0 2146,0 3650,0 32309 350 kcmil - 32195 350 kcmil -
4 x 185 sm 51,0 2146,0 3650,0 32180 350 kcmil - 32196 350 kcmil -
4 x 240 se 56,0 2784,0 4800,0 32310 500 kcmil - 32197 500 kcmil -
4 x 240 sm 56,0 2784,0 4800,0 32181 500 kcmil - 32198 500 kcmil -
4 x 300 se 64,0 3480,0 5596,0 32182 600 kcmil - 32199 600 kcmil -
4 x 300 sm 64,0 3480,0 5596,0 32183 600 kcmil - 32258 600 kcmil -

Continuation

544
Energy- and Power Cable / Power Cables / Power cables for energy supply

NAYY power cable, 0,6/1 kV, VDE approved


No.cores x Outer Alu weight Weight J type AWG-No. O type AWG-No.
cross-sec. app. mm kg / km app. kg / km Part no. Part no.
mm
5 x 10 re 22,0 145,0 637,0 33275 8 - 33283 8 -
5 x 16 re 25,0 232,0 832,0 33276 6 - 33284 6 -
5 x 25 re 28,0 363,0 1175,0 33277 4 - 33285 4 -
5 x 35 re 31,0 508,0 1399,0 33278 2 - 33286 2 -
5 x 50 rm 35,0 725,0 1855,0 33279 1 - 33287 1 -
5 x 70 rm 40,0 1015,0 2351,0 33280 2/0 - 33288 2/0 -
5 x 95 rm 45,0 1378,0 3071,0 33281 3/0 - 33289 3/0 -
5 x 120 rm 49,0 1740,0 3631,0 33282 4/0 - 33290 4/0 -
5 x 150 rm 57,8 2175,0 4405,0 34041 300 kcmil - 34042 300 kcmil -
5 x 185 rm 61,5 2683,0 5420,0 34043 350 kcmil - 34044 350 kcmil -
5 x 240 rm 70,0 3480,0 6860,0 34045 500 kcmil - 34046 500 kcmil -

No.cores x Outer Alu weight Weight J type AWG-No. O type AWG-No.


cross-sec. app. mm kg / km app. kg / km Part no. Part no.
mm
1 x 35 re 13,0 102,0 240,0 32328 2 - 32311 2 -
1 x 50 re 15,0 145,0 360,0 32329 1 - 32312 1 -
1 x 70 rm 16,5 203,0 410,0 32390 2/0 - 32313 2/0 -
1 x 95 rm 19,0 276,0 570,0 32391 3/0 - 32314 3/0 -
1 x 120 rm 20,5 348,0 691,0 32392 4/0 - 32315 4/0 -
1 x 150 rm 22,5 435,0 804,0 32393 300 kcmil - 32321 300 kcmil -
1 x 185 rm 25,0 537,0 979,0 32394 350 kcmil - 32322 350 kcmil -
1 x 240 rm 28,0 696,0 1253,0 32395 500 kcmil - 32323 500 kcmil -
1 x 300 rm 30,0 870,0 1395,0 32396 600 kcmil - 32324 600 kcmil -
1 x 400 rm 34,0 1160,0 1890,0 32397 750 kcmil - 32325 750 kcmil -
1 x 500 rm 38,0 1450,0 2600,0 32398 1000 kcmil - 32326 1000 kcmil -
1 x 630 rm 43,0 1827,0 2780,0 32399 1250 kcmil - 32327 1250 kcmil -

Dimensions and specifications may be changed without prior notice. (RQ01)

3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP

545
Energy- and Power Cable / Power Cables / Power cables for energy supply

NAY2Y power cable, 0,6/1kV, with PE-outer sheath

Technical data Cable structure Properties


Power and control cable to Aluminium-conductor, to outer sheath PE of not
DIN VDE 0276 part 603, DIN VDE 0295 cl.1, single-wire, self-extinguishing and flame retardant
HD 603 S1 and IEC 60502 BS 6360 cl.1, IEC 60228 cl.1 The materials used in manufacture are
Temperature range Core insulation of PVC cadmium-free and contain no silicone
flexing -5C to +50C Core identification GN-YE, BN, BK, GY and free from substances harmful to
fixed installation -40C to +70C Cores stranded in concentric layers the wetting properties of lacquers
Permissible operating temperature Common core sheath Highest permissible voltage
at conductor +70C Outer sheath of PE Direct current systems 1,8 kV
Permissible short circuit temperature Sheath colour black Alternating current systems
(short circuit duration max. 5 s) Single-phase systems
+160C both outer conductors insulated 1,4 kV
Nominal voltage U0/U 0,6/1 kV Single-phase systems
Test voltage 4 kV one outer conductor earthed 0,7 kV
Max. permissible tensile stress Three-phase systems 1,2 kV
with cable grip at conductor
30 N/mm Note
Minimum bending radius re = round conductor, single-wire
12x cable se = sectional conductor, single-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Power cables for energy supply are installed in open air, in underground, in water, in concrete, indoors, in cable ducts, power stations, for industry
and distribution boards as well as in subscriber networks. Usable in extreme working conditions due to the robust PE outer sheath.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Alu weight Weight AWG-No.


cross-sec. app. mm kg / km app. kg / km
mm
31129 4 x 25 re 26,0 290,0 970,0 4
31139 4 x 35 re 28,0 406,0 1145,0 2
31149 4 x 50 se 30,0 580,0 1184,0 1
31159 4 x 70 se 33,0 812,0 1578,0 2/0
31169 4 x 95 se 38,0 1102,0 2186,0 3/0
31179 4 x 120 se 42,0 1382,0 2501,0 4/0
31189 4 x 150 se 45,0 1740,0 3180,0 300 kcmil
31199 4 x 185 se 51,0 2146,0 3807,0 350 kcmil
31209 4 x 240 se 55,0 2784,0 4996,0 500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ01)

546
Energy- and Power Cable / Power Cables / Power cables for energy supply

NAYCWY power cable, 0,6/1kV, with concentric copper conductor, VDE approved

Technical data Cable structure Properties


Power and control cable to Aluminium-conductor, to DIN VDE 0295 The materials used in manufacture are
DIN VDE 0276 part 603, cl.1 or cl.2, single-wire or multi-wire, cadmium-free and contain no silicone
HD 603 S1 and IEC 60502 BS 6360 cl.1 or cl.2, IEC 60228 and free from substances harmful to
Temperature range cl.1 or cl.2 the wetting properties of lacquers
flexing -5C to +50C Core insulation of PVC Tests
fixed installation -40C to +70C compound type DIV4 to HD 603 S1 PVC self-extinguishing and flame retardant
Permissible operating temperature Core identification DIN VDE 0293-308 acc. to DIN VDE 0482-332-1-2,
at conductor +70C Cores stranded concentrically DIN EN 60332-1-2, IEC 60332-1 (equivalent
Permissible short circuit temperature Filling compound DIN VDE 0472 part 804 test method B)
(short circuit duration max. 5 s) Concentric conductor (Ceander), Highest permissible voltage
+160C inner layer of corrugated copper wires, Direct current systems 1,8 kV
Nominal voltage U0/U 0,6/1 kV outer layerwith copper tape Alternating current systems
Test voltage 4 kV Outer sheath of PVC Single-phase systems
Max. permissible tensile stress compound type DMV5 to HD 603 S1 both outer conductors insulated 1,4 kV
with cable grip at conductor Sheath colour black Single-phase systems
30 N/mm one outer conductor earthed 0,7 kV
Minimum bending radius Three-phase systems 1,2 kV
12x cable with concentric conductor and
a cross-section from 240 mm 3,6 kV

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
sm = sectional conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Power distribution cables, preferably used for underground installation, primarily in local networks, for industrial applications and switching systems,
power stations. Wherever increased electrical and mechanical protection are required. Installation in water, outdoors, in concrete, indoors and in cable
ducts. The concentric conductor (C) can be used as a PE or PEN conductor or as a screen. The corrugated design (Ceander) of the conc entric conductor
permits any number of cable junctions during assembly, without any conductors having to be cut. This ensures a optimal reliability.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Alu weight Weight AWG-No.


cross-sec. app. mm weight kg / km app. kg / km
mm kg / km
36009 3 x 10 re / 10 20,2 88,0 87,0 603,0 8
36010 3 x 16 re / 16 22,3 125,0 139,0 754,0 6
36011 3 x 25 re / 25 25,5 170,0 218,0 1043,0 4
36012
36013
3 x 25
3 x 25
rm / 16
rm / 25
26,6
26,6
125,0
170,0
218,0
218,0
1046,0
1101,0
4
4 Q
36014 3 x 35 re / 35 27,6 240,0 305,0 1243,0 2
36015 3 x 35 sm / 16 26,4 125,0 305,0 1002,0 2
36016 3 x 35 sm / 35 26,4 240,0 305,0 1107,0 2
36017 3 x 50 sm / 25 29,4 170,0 435,0 1283,0 1
36018 3 x 70 sm / 35 32,6 240,0 609,0 1633,0 2/0
36019 3 x 70 sm / 70 33,4 475,0 609,0 1838,0 2/0
36020 3 x 95 sm / 50 38,1 340,0 827,0 2136,0 3/0
36021 3 x 95 sm / 95 38,1 640,0 827,0 2449,0 3/0
36022 3 x 120 sm / 50 40,8 340,0 1044,0 2517,0 4/0
36023 3 x 120 sm / 70 40,8 475,0 1044,0 2612,0 4/0
36024 3 x 150 sm / 70 44,9 475,0 1305,0 3019,0 300 kcmil
36025 3 x 150 sm / 150 45,5 1000,0 1305,0 3517,0 300 kcmil
36026 3 x 185 sm / 70 49,8 475,0 1610,0 3741,0 350 kcmil
36027 3 x 185 sm / 95 49,8 640,0 1610,0 3895,0 350 kcmil
36028 3 x 240 sm / 70 55,4 475,0 2088,0 4539,0 500 kcmil
36029 3 x 240 sm / 120 55,8 800,0 2088,0 4838,0 500 kcmil
36030 3 x 240 sm / 240 56,0 1665,0 2088,0 5611,0 500 kcmil
32840 4 x 16 re / 16 23,9 125,0 186,0 801,0 6
32841 4 x 25 re / 16 28,9 125,0 290,0 1243,0 4
32842 4 x 35 re / 16 30,3 125,0 406,0 1282,0 2
32843 4 x 50 sm / 25 34,8 170,0 580,0 1689,0 1
32844 4 x 70 sm / 35 38,6 240,0 814,0 2074,0 2/0
32845 4 x 95 sm / 50 44,4 340,0 1102,0 2779,0 3/0
32846 4 x 120 sm / 70 48,7 475,0 1392,0 3365,0 4/0
32847 4 x 150 sm / 70 53,3 475,0 1740,0 3813,0 300 kcmil
32848 4 x 185 sm / 95 59,1 640,0 2146,0 4877,0 350 kcmil
32849 4 x 240 sm / 120 66,0 800,0 2784,0 6017,0 500 kcmil

Dimensions and specifications may be changed without prior notice.

547
Energy- and Power Cable / Power Cables / Power cables for energy supply

N2XY power cable, 0,6/1kV, VDE approved, higher current carrying capacity

Technical data Cable structure Properties


Power and control cable to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0276 part 603, DIN VDE 0295 cl.1 or cl.2, single-wire cadmium-free and contain no silicone
HD 603 S1 and IEC 60502 or multi-wire, BS 6360 cl.1 or cl.2, and free from substances harmful to
Temperature range IEC 60228 cl.1 or cl.2 the wetting properties of lacquers
flexing -5C to +50C Core insulation of cross-linked Tests
fixed installation -40C to +70C polyethylene (XLPE) self-extinguishing and flame retardant
Permissible operating temperature compound type DIX3 acc. to DIN VDE 0482-332-1-2,
at conductor +90C to HD 603 S1 DIN EN 60332-1-2, IEC 60332-1 (equivalent
Permissible short circuit temperature Core identification to DIN VDE 0472 part 804 Test method B)
(short circuit duration max. 5 s) DIN VDE 0293-308, 0276 part 603 Highest permissible voltage
+250C Cores stranded in concentric layers Direct current systems 1,8 kV
Nominal voltage U0/U 0,6/1 kV Outer sheath of PVC Alternating current systems
Test voltage 4 kV compound type DMV6/DMP2 Single-phase systems
Max. permissible tensile stress to HD 603 S1 both outer conductors insulated 1,4 kV
with cable grip at comductor Sheath colour black Single-phase systems
50 N/mm one outer conductor earthed 0,7 kV
Minimum bending radius Three-phase systems 1,2 kV
single-core 15x cable
multi-core 12x cable Note
re = round conductor, single-wire
rm = round conductor, multi-wire
sm = sectional conductor, multi-wire
J-version = with GN-YE conductor
O-version = without GN-YE conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Power distribution cables for use in underground, in water, outdoors, in concrete, indoors, in cable ducts, for power stations, industrial applications
and switching systems, as well as in local networks if no mechanical damage is expected. Respecting the permissible operating temperature at the
conductor of +90C permits a higher current carrying capacity than PVC insulated power distribution cables.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

No.cores x Outer Cop. Weight J type AWG-No. O type AWG-No.


cross-sec. app. mm weight app. kg / km Part no. Part no.
mm kg / km
1 x 16 re 11,5 154,0 242,0 32850 6 - 32862 6 -
1 x 25 rm 12,5 240,0 362,0 32851 4 - 32863 4 -
1 x 35 rm 13,5 336,0 470,0 32852 2 - 32864 2 -
1 x 50 rm 15,5 480,0 620,0 32853 1 - 32865 1 -
1 x 70 rm 17,0 672,0 805,0 32854 2/0 - 32866 2/0 -
1 x 95 rm 19,0 912,0 1108,0 32855 3/0 - 32867 3/0 -
1 x 120 rm 20,5 1152,0 1360,0 32856 4/0 - 32868 4/0 -
1 x 150 rm 23,0 1440,0 1670,0 32857 300 kcmil - 32869 300 kcmil -
1 x 185 rm 25,5 1776,0 2050,0 32858 350 kcmil - 32870 350 kcmil -
1 x 240 rm 28,5 2304,0 2635,0 32859 500 kcmil - 32871 500 kcmil -
1 x 300 rm 30,0 2880,0 3200,0 32860 600 kcmil - 32872 600 kcmil -
1 x 400 rm 34,0 3840,0 4150,0 32861 750 kcmil - 32873 750 kcmil -
4 x 16 rm 21,5 614,0 1042,0 32874 6 - 32884 6 -
4 x 25 rm 26,0 960,0 1640,0 32875 4 - 32885 4 -
4 x 35 rm 27,5 1344,0 1760,0 32876 2 - 32886 2 -
4 x 50 sm 30,0 1920,0 2350,0 32877 1 - 32887 1 -
4 x 70 sm 34,0 2688,0 3100,0 32878 2/0 - 32888 2/0 -
4 x 95 sm 39,0 3648,0 4250,0 32879 3/0 - 32889 3/0 -
4 x 120 sm 42,5 4608,0 5300,0 32880 4/0 - 32890 4/0 -
4 x 150 sm 47,5 5760,0 6400,0 32881 300 kcmil - 32891 300 kcmil -
4 x 185 sm 52,0 7104,0 8500,0 32882 350 kcmil - 32892 350 kcmil -
4 x 240 sm 58,0 9216,0 11000,0 32883 500 kcmil - 32893 500 kcmil -

Dimensions and specifications may be changed without prior notice. (RQ02)

548
Energy- and Power Cable / Power Cables / Power cables for energy supply

N2XCY power cable, 0,6/1kV, VDE approved, higher current carrying capacity

Technical data Cable structure Properties


Power and control cable to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0276 part 603, DIN VDE 0295 cl.1 or cl.2, single-wire cadmium-free and contain no silicone
HD 603 S1 and IEC 60502, or multi-wire, BS 6360 cl.1 or cl.2, and free from substances harmful to
7 cores and above to DIN VDE 0276 IEC 60228 cl.1 or cl.2 the wetting properties of lacquers
part 627, HD 627 S1 and IEC 60502 Core insulation of cross-linked Tests
Temperature range polyethylene (XLPE) self-extinguishing and flame retardant
flexing -5C to +50C compound type DIX3 to HD 603 S1 acc. to DIN VDE 0482-332-1-2,
fixed installation -40C to +70C Core identification to DIN VDE 0293-308 DIN EN 60332-1-2, IEC 60332-1 (equivalent
Permissible operating temperature Cores stranded in concentric layers DIN VDE 0472 part 804 test method B)
at conductor +90C Filling compound Highest permissible voltage
Permissible short circuit temperature Concentric conductor, inner layer of round Direct current systems 1,8 kV
(short circuit duration max. 5 s) bare copper wires, outer layer of copper Alternating current systems
+250C tape as counter helix Single-phase systems
Nominal voltage U0/U 0,6/1 kV Outer sheath of PVC both outer conductors insulated 1,4 kV
Test voltage 4 kV compound type DMV6 to HD 603 S1 Single-phase systems
Max. permissible tensile stress Sheath colour black one outer conductor earthed 0,7 kV
with cable grip at conductor Three-phase systems 1,2 kV
50 N/mm
Minimum bending radius Note
12x cable re = round conductor, single-wire
rm = round conductor, multi-wire
sm = sectional conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Power distribution cables for industrial applications and switching systems, power stations, residental connections and street lighting, as well as control
cables for transmitting control pulses and measurements. Wherever increased electrical and mechanical protection are required. For installation in
underground, in water, outdoors, in concrete and cable ducts. Respecting the permissible operating temperature at the conductor of +90C permits
a higher current carrying capacity than PVC insulated power distribution cables. The concentric conductor (C) can be used as a PE or PEN-conductor
or as a screen.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No.


cross-sec. app. mm weight app. kg / km
mm kg / km
33212 2 x 1,5 re / 1,5 13,0 53,0 205,0 16
33213 2 x 2,5 re / 2,5 13,5 80,0 270,0 14
33214 2x4 re / 4 15,5 123,0 360,0 12
33215 2x6 re / 6 17,0 182,0 435,0 10
33216
33217
2 x 10
2 x 16
re / 10
re / 16
19,5
20,5
312,0
489,0
590,0
820,0
8
6 Q
33218 3 x 1,5 re / 1,5 13,5 66,0 225,0 16
33219 3 x 2,5 re / 2,5 14,5 104,0 290,0 14
33220 3x4 re / 4 16,5 161,0 400,0 12
33221 3x6 re / 6 17,5 240,0 510,0 10
33222 3 x 10 re / 10 20,0 408,0 850,0 8
33223 3 x 16 re / 16 23,0 643,0 1080,0 6
33224 3 x 25 rm / 16 25,1 902,0 1295,0 4
33225 3 x 25 rm / 25 25,0 1003,0 1375,0 4
33226 3 x 35 sm / 16 25,1 1190,0 1441,0 2
33227 3 x 35 sm / 35 25,4 1402,0 1619,0 2
33228 3 x 50 sm / 25 27,3 1723,0 1902,0 1
33229 3 x 50 sm / 50 27,7 2000,0 2107,0 1
33230 3 x 70 sm / 35 32,2 2410,0 2700,0 2/0
33231 3 x 70 sm / 70 32,7 2796,0 3005,0 2/0
33232 3 x 95 sm / 50 35,3 3296,0 3588,0 3/0
33233 3 x 95 sm / 95 35,8 3791,0 4017,0 3/0
33234 3 x 120 sm / 120 38,9 4786,0 4998,0 4/0
33235 3 x 120 sm / 70 38,9 4236,0 4534,0 4/0
33236 3 x 150 sm / 120 43,4 5970,0 5937,0 300 kcmil
33237 3 x 150 sm / 70 43,4 5100,0 5473,0 300 kcmil
33238 3 x 185 sm / 95 47,4 6383,0 6831,0 350 kcmil
33239 3 x 240 sm / 120 52,5 8242,0 8809,0 500 kcmil

Continuation

549
Energy- and Power Cable / Power Cables / Power cables for energy supply

N2XCY power cable, 0,6/1kV, VDE approved, higher current carrying capacity
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km
mm kg / km
33240 4 x 1,5 re / 1,5 14,5 81,0 260,0 16
33241 4 x 2,5 re / 2,5 15,5 128,0 350,0 14
33242 4x4 re / 4 17,0 200,0 470,0 12
33243 4x6 re / 6 18,5 297,0 590,0 10
33244 4 x 10 re / 10 21,0 504,0 900,0 8
33245 4 x 16 re / 16 23,0 796,0 1250,0 6
33246 4 x 25 re / 16 27,2 1142,0 1559,0 4
33247 4 x 35 sm / 16 27,2 1526,0 1812,0 2
33248 4 x 50 sm / 25 30,6 2203,0 2413,0 1
33249 4 x 70 sm / 35 35,9 3082,0 3420,0 2/0
33250 4 x 95 sm / 50 39,5 4208,0 4561,0 3/0
33251 4 x 120 sm / 16 44,5 5388,0 5819,0 4/0
33252 4 x 150 sm / 70 48,6 6540,0 6972,0 300 kcmil
33253 5 x 1,5 re / 1,5 15,0 95,0 330,0 16
33254 5 x 2,5 re / 2,5 16,0 152,0 400,0 14
33255 5x4 re / 4 19,0 238,0 560,0 12
33256 5x6 re / 6 21,0 355,0 710,0 10
33257 5 x 10 re / 10 23,0 600,0 1000,0 8
33258 5 x 16 re / 16 24,3 931,0 1233,0 6
33259 7 x 1,5 re / 1,5 16,0 133,0 350,0 16
33260 7 x 2,5 re / 2,5 17,5 200,0 450,0 14
33261 7x4 re / 4 21,0 315,0 670,0 12
33262 7x6 re / 6 24,0 470,0 790,0 10
33263 10 x 1,5 re / 2,5 19,0 176,0 440,0 16
33264 10 x 2,5 re / 4 20,5 286,0 600,0 14
33265 12 x 1,5 re / 2,5 20,0 205,0 500,0 16
33266 12 x 2,5 re / 4 21,0 334,0 660,0 14
33267 14 x 1,5 re / 2,5 20,5 234,0 540,0 16
33268 14 x 2,5 re / 6 22,5 403,0 800,0 14
33269 19 x 1,5 re / 2,5 23,0 320,0 690,0 16
33270 19 x 2,5 re / 6 23,5 523,0 950,0 14
33271 30 x 1,5 re / 2,5 27,0 499,0 1230,0 16
33272 30 x 2,5 re / 10 30,0 840,0 1610,0 14
33273 40 x 1,5 re / 2,5 30,0 696,0 1590,0 16
33274 40 x 2,5 re / 10 35,0 1080,0 2100,0 14

Dimensions and specifications may be changed without prior notice. (RQ01)

3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP

550
Energy- and Power Cable / Power Cables / Power cables for energy supply

NA2XY power cable, 0,6/1kV, VDE approved, higher current carrying capacity

Technical data Cable structure Properties


Power and control cable to Aluminium-conductor to DIN VDE 0295 The materials used in manufacture are
DIN VDE 0276 Part 603, cl.1 or cl.2, single-wire or multi-wire, cadmium-free and contain no silicone
HD 603 S1 and IEC 60502 BS 6360 cl.1 or cl.2, IEC 60228 and free from substances harmful to
Temperature range cl.1 or cl.2 the wetting properties of lacquers
flexing -5C to +50C Core insulation of cross-linked Tests
fixed installation -40C to +70C polyethylene (XLPE) self-extinguishing and flame retardant
Permissible operating temperature compound type DIX3 to HD 603 S1 acc. to DIN VDE 0482-332-1-2,
at conductor +90C Core identification to DIN EN 60332-1-2, IEC 60332-1 (equivalent
Permissible short circuit temperature DIN VDE 0293-308, 0276 part 603 DIN VDE 0472 part 804 test method B)
(short circuit duration max. 5 s) Cores stranded in concentric layers Highest permissible voltage
+250C Outer sheath of PVC Direct current systems 1,8 kV
Nominal voltage U0/U 0,6/1 kV compound type DMV6/DMP2 Alternating current systems
Test voltage 4 kV to HD 603 S1 Single-phase systems
Max. permissible tensile stress Sheath colour black both outer conductors insulated 1,4 kV
with cable grip at conductor Single-phase systems
30 N/mm one outer conductor earthed 0,7 kV
Minimum bending radius Three-phase systems 1,2 kV
single-core 15x cable
multi-core 12x cable Note
re = round conductor, single-wire
rm = round conductor, multi-wire
se = sectional conductor, single-wire
J-version = with GN-YE conductor
O-version = without GN-YE conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Power distribution cables for use in underground, in water, outdoors, in concrete, indoors, in cable ducts, for power stations, industrial applications
and switching systems, as well as in local networks if no mechanical damage is expected. Respecting the permissible operating temperature at the
conductor of +90C permits a higher current carrying capacity than PVC insulated power distribution cables.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

No.cores x Outer Alu weight Weight J type AWG-No. O type AWG-No.


cross-sec. app. mm kg / km app. kg / km Part no. Part no.
mm
1 x 16 re 11,5 47,0 98,0 33113 6 - 33125 6 -
1 x 25 re 12,5 73,0 150,0 33114 4 - 33126 4 -
1 x 35 re 13,5 102,0 241,0 33115 2 - 33127 2 -
1 x 50 rm 15,5 145,0 357,0 33116 1 - 33128 1 -
1 x 70
1 x 95
rm
rm
17,0
19,0
203,0
276,0
409,0
570,0
33117
33118
2/0
3/0
-
-
33129
33130
2/0
3/0
-
-
Q
1 x 120 rm 20,5 348,0 590,0 33119 4/0 - 33131 4/0 -
1 x 150 rm 23,0 435,0 804,0 33120 300 kcmil - 33132 300 kcmil -
1 x 185 rm 25,5 537,0 978,0 33121 350 kcmil - 33133 350 kcmil -
1 x 240 rm 28,5 696,0 1253,0 33122 500 kcmil - 33134 500 kcmil -
1 x 300 rm 30,0 870,0 1394,0 33123 600 kcmil - 33135 600 kcmil -
1 x 400 rm 34,0 1160,0 1890,0 33124 750 kcmil - 33136 750 kcmil -
4 x 16 re 21,5 186,0 750,0 33137 6 - 33147 6 -
4 x 25 re 26,0 290,0 950,0 33138 4 - 33148 4 -
4 x 35 re 27,5 406,0 1120,0 33139 2 - 33149 2 -
4 x 50 se 30,0 580,0 1251,0 33140 1 - 33150 1 -
4 x 70 se 34,0 812,0 1548,0 33141 2/0 - 33151 2/0 -
4 x 95 se 39,0 1102,0 2030,0 33142 3/0 - 33152 3/0 -
4 x 120 se 42,5 1392,0 2400,0 33143 4/0 - 33153 4/0 -
4 x 150 se 47,5 1740,0 3030,0 33144 300 kcmil - 33154 300 kcmil -
4 x 185 se 52,0 2146,0 3650,0 33145 350 kcmil - 33155 350 kcmil -
4 x 240 se 58,0 2784,0 4800,0 33146 500 kcmil - 33156 500 kcmil -

Dimensions and specifications may be changed without prior notice. (RQ02)

551
Energy- and Power Cable / Power Cables / Power cables for energy supply

A-LiY(StE)Y Data transmission cables for petrol stations and refineries with BAM*-test
report

Technical data Cable structure Properties


Oil- and fuel-resistant data Bare copper-conductor, fine-wire Tests
transmission cables Part.-No. 32597, 32599 Compound characteristic acc. to
Temperature range Tinned copper-conductor, single-wire DIN VDE 0207
flexing -5C to +70C Part.-No. 32633 Oil- and fuel resistance of sheath:
fixed installation -40C to +70C Core insulation of special PVC acc. to BAM-Specification
Nominal voltage 200 V to DIN VDE 0207 Oil-resistance of sheath:
Insulation resitance Core identification black cores with DIN ISO 6722 part 1, 4.11,
min. 100 MOhm x km continuous white numbering DIN EN 60811-404
Minimum bending radius Each single core screened with aluminium/ Fuel-resistance of sheath:
20x cable polyester foil, metal layer at outside DIN ISO 6722 part 1, 4.12
Radiation resistance Screened cores in layers with optimal PVC self-extinguishing and flame retardant
up to 80x106 cJ/kg (up to 80 Mrad) lay-lenght screenings of each core make acc. to DIN VDE 0482-332-1-2,
contact mutually DIN EN 60332-1-2, IEC 60332-1 (equivalent
Solid copper drain-wire Part.-No. 32633 DIN VDE 0472 part 804 test method B)
copper drain-wire Part.-No. 32597, 32599
Common core sheath Note
Outer sheath of special PVC BAM = Federal Institute for Materials
Sheath colour black Research and Testing
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These data transmission cables, oil- and fuel-resistant, are used for internal and external wiring applications at petrol pumps, for data transmission
from the pumps to the cash desk and in the installation of video surveillance systems. These cables are also installed directly in the ground and are
resistant to UV radiation. Special screens over individual cores guarantee good overall screening and ensure an interference-free transmission of control
pulses.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
32597 4 x 0,75 9,0 38,0 105,0 18 32599 8 x 0,75 11,0 68,0 169,0 18
32633 7 x 0,75 10,3 60,0 150,0 18

Dimensions and specifications may be changed without prior notice. (RQ01)

3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP

552
Energy- and Power Cable / Power Cables / Power cables for energy supply

Petrol Station Cables (N)YY-J 0,6/1 kV

Technical data Cable structure Properties


Power and data transmission cable Bare copper-conductor, to Tests
adapted to DIN VDE 0271 DIN VDE 0295 cl.1, single-wire, Oil and fuel-resistant acc. to
Temperature range BS 6360 cl.1, IEC 60228 cl.1 DIN ISO 6722
flexing -5C to +50C Core insulation of PVC PVC self-extinguishing and flame retardant
fixed installation -30C to +70C Core identification to DIN VDE 0293-308 acc. to DIN VDE 0482-332-1-2,
Permissible operating temperature Concentric lay-up of cores DIN EN 60332-1-2, IEC 60332-1 (equivalent
at conductor +70C Outer sheath of PVC DIN VDE 0472 part 804 test method B)
Nominal voltage U0/U 0,6/1 kV Sheath colour black 1) DIN VDE 0298 part 1 is shall be observed.
Test voltage 4 kV
Max. permissible tensile stress Note
with cable grip at conductor 1) Version with blue outer sheath on request.
50 N/mm AWG sizes are approximate equivalent
Minimum bending radius values. The actual cross-section is in mm.
12x cable

Application
Energy and data transmission cables for outdoor use, in the soil, water and concrete, where mechanical damage is excluded . For installations in
applications such as gas stations and refineries, where resistance to oils and fuels is required .
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
32592 2 x 1,5 11,0 29,0 180,0 16 32595 5 x 1,5 13,0 72,0 280,0 16
32593 3 x 1,5 11,5 43,0 225,0 16 32596 7 x 1,5 15,5 101,0 370,0 16
32594 4 x 1,5 12,0 58,0 260,0 16

Dimensions and specifications may be changed without prior notice. (RQ01)

3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP

553
Energy- and Power Cable / Power Cables / Power cables for energy supply

NYKY-J 0,6/1kV with lead sheath, VDE approved

Technical data Cable structure Properties


Power and control cable, PVC insulation Bare copper-conductor, to Advantage
and lead inner-sheath to DIN VDE 0265 DIN VDE 0295 cl.1 or cl.2, single-wire Good coupling resistance due to
Temperature range or multi-wire, BS 6360 cl.1 or cl.2, enclosed lead sheath is suitable
flexing -5C to +50C IEC 60228 cl.1 or cl.2 for special EMC-requirements
fixed installation -30C to +70C Core insulation of PVC (Electromagnetic Compatibility)
Permissible operating temperature compound type DIV4 to Resistant to
at conductor +70C DIN VDE 0276 part 603 Turpentine substitute
Permissible short circuit temperature Core identification to DIN VDE 0293-308 Xylol
(short circuit duration max. 5 s ) - up to 5 cores coloured Fuels
+160C - from 7 cores, black with continuous Trichlor
Nominal voltage U0/U 0,6/1 kV white numbering Oils
Test voltage 6 kV GN-YE conductor Petroleum
Minimum bending radius Cores stranded concentrically Toluene
12x cable Overall sheath of soft plastics material, if Hydrocarbon
Power ratings table exists, ermits also as extrusion or taping The lead sheath is not permitted to use as
see Technical Informations or a combination of both neutral-conductor (N)
Lead inner sheath, jointless and enclosed If drain-wire exists, only for use as earthing
Outer sheath of PVC of lead sheath in a grounding system e.g.
compound type DMV5 to in hazardous areas to DIN VDE 0165. This
DIN VDE 0276 part 603 drain-wire is not allowed to install as
Sheath colour black protective, neutral or earth conductor

Note
re = round conductor, single-wire
sm = sectional conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
These cables of PVC insulation and lead inner-sheath are installed everywhere, where the danger of chemical reaction of solvents, energy fuels, oils,
gasolines or of that kind in filling stations particularly in petrol pump areas for carburetor propellants, in refining plants and in chemical industries are
to be caused. Suitable for installation under ground, in water, indoor areas and cable conduits.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Lead Weight AWG-No.


cross-sec. app. mm weight weight app. kg / km
mm kg / km kg / km
32640 3 x 1,5 re 13,5 43,0 427,0 598,0 16
32686 3 x 1,5 re / 1,5 14,5 57,0 427,0 610,0 16
32641 3 x 2,5 re 14,8 72,0 487,0 690,0 14
32642 3x4 re 16,2 115,0 555,0 840,0 12
32643 3x6 re 17,3 173,0 610,0 990,0 10
32644 3 x 25 rm / 16 27,8 874,0 1290,0 2550,0 4
32645 3 x 35 sm / 16 29,2 1162,0 1340,0 3080,0 2
32646 3 x 50 sm / 25 32,7 1680,0 1670,0 3850,0 1
32647 3 x 70 sm / 35 35,8 2352,0 2020,0 5360,0 2/0
32648 3 x 95 sm / 50 40,3 3216,0 2440,0 6950,0 3/0
32649 3 x 120 sm / 70 43,2 4128,0 2770,0 8235,0 4/0
32650 3 x 150 sm / 70 48,8 4992,0 3530,0 9620,0 300 kcmil
32651 3 x 185 sm / 95 53,4 6240,0 4230,0 11940,0 350 kcmil
32652 3 x 240 sm / 120 59,8 8064,0 5230,0 15380,0 500 kcmil

Continuation

554
Energy- and Power Cable / Power Cables / Power cables for energy supply

NYKY-J 0,6/1kV with lead sheath, VDE approved


Part no. No.cores x Outer Cop. Lead Weight AWG-No.
cross-sec. app. mm weight weight app. kg / km
mm kg / km kg / km
32653 4 x 1,5 re 14,5 58,0 464,0 650,0 16
32687 4 x 1,5 re / 1,5 15,3 72,0 464,0 650,0 16
32654 4 x 2,5 re 15,5 96,0 530,0 760,0 14
32655 4x4 re 17,5 154,0 605,0 960,0 12
32656 4x6 re 18,5 230,0 665,0 1100,0 10
32657 4 x 10 re 21,3 384,0 750,0 1400,0 8
32658 4 x 16 re 24,2 614,0 975,0 1910,0 6
32659 4 x 25 rm 28,5 960,0 1290,0 2750,0 4
32660 4 x 35 rm 30,5 1344,0 1340,0 3630,0 2
32661 4 x 50 sm 33,3 1920,0 1680,0 4580,0 1
32662 4 x 70 sm 37,5 2688,0 2020,0 5340,0 2/0
32663 4 x 95 sm 42,3 3648,0 2440,0 7120,0 3/0
32664 5 x 1,5 re 15,3 72,0 505,0 710,0 16
32688 5 x 1,5 re / 1,5 16,4 86,0 505,0 780,0 16
32665 5 x 2,5 re 17,2 120,0 580,0 910,0 14
32666 5x4 re 19,4 192,0 665,0 1090,0 12
32667 5x6 re 20,2 288,0 730,0 1270,0 10
32668 5 x 10 re 22,8 480,0 930,0 1700,0 8
32669 5 x 16 re 26,4 768,0 1070,0 2231,0 6
32670 7 x 1,5 re 17,2 101,0 545,0 810,0 16
32689 7 x 1,5 re / 1,5 17,2 115,0 545,0 970,0 16
32678 7 x 2,5 re 18,0 168,0 625,0 1070,0 14
32671 10 x 1,5 re 21,3 144,0 680,0 918,0 16
32679 10 x 2,5 re 22,4 240,0 865,0 1330,0 14
32672 12 x 1,5 re 21,3 173,0 710,0 988,0 16
32680 12 x 2,5 re 23,2 288,0 940,0 1440,0 14
32673 14 x 1,5 re 21,3 202,0 735,0 1100,0 16
32681 14 x 2,5 re 24,5 336,0 980,0 1530,0 14
32674 19 x 1,5 re 23,0 274,0 900,0 1440,0 16
32682 19 x 2,5 re 26,0 456,0 1170,0 1680,0 14
32675 24 x 1,5 re 27,3 346,0 1170,0 1610,0 16
32683 24 x 2,5 re 31,0 576,0 1370,0 2160,0 14
32676 30 x 1,5 re 28,2 432,0 1240,0 1830,0 16
32684 30 x 2,5 re 32,3 720,0 1550,0 2530,0 14
32677 40 x 1,5 re 31,4 576,0 1390,0 2300,0 16
32685 40 x 2,5 re 36,4 960,0 1770,0 3310,0 14

Dimensions and specifications may be changed without prior notice. (RQ01)

3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP

555
LOW-VOLTAGE & SAFETY CABLES

556
Energy- and Power Cable / Low Voltage and Security Cables

N2XH power cable, 0,6/1 kV, halogen-free, without functionality

Technical data Cable structure Properties


Power and control cable acc. to Bare copper-conductor, to Halogen-free, no separation of corrosive
DIN VDE 0276 part 604, DIN VDE 0295 cl.1 or cl.2, single-wire or toxic gases
HD 604 S1 part 1 and part 5G or multi-wire, BS 6360 cl.1 or cl.2, Limited propagation of fire
Temperature range IEC 60228 cl.1 or cl.2 Low smoke development
during installation -5C to +50C Core insulation of cross-linked The materials used in manufacture are
fixed installation -30C to +90C polyethylene (XLPE) cadmium-free and contain no silicone
Permissible operating temperature compound type 2XI1 to HD 604 S1 and free from substances harmful to
at conductor +90C Core identification to DIN VDE 0293-308 the wetting properties of lacquers
Nominal voltage U0/U 0,6/1 kV Core identification for 3+ conductor Tests
Test voltage 4 kV J-type: GN-YE (), BN, BK, GY Flame test acc. to DIN VDE 0482-332-3-24,
Minimum bending radius O-type: BU (), BN, BK, GY BS 4066 part 3, DIN EN 60332-3-24,
single-core 15x cable Cores stranded in layers IEC 60332-3-24 (previously DIN VDE 0472
multi-core 12x cable (for multi-core cables) part 804 test method C)
Radiation resistance Overall filled inner sheath Corrosiveness of combustion gases
up to 100x106 cJ/kg (up to 100 Mrad) Covered by filling compound or taping acc. to DIN VDE 0482 part 267,
Caloric load values Outer sheath of thermoplastic DIN EN 50267-2-2, IEC 60754-2
see Technical Informations polyolefine, compound type HM4 (equivalent DIN VDE 0472 part 813)
to HD 604 S1 Halogen-free acc. to DIN VDE 0482
Sheath colour black part 267, DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
sm = sectional conductor, mutli-wire
J-version = with GN-YE conductor
O-version = without GN-YE conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen

Application
Halogen-free power cables with enhanced characteristics in case of fire are used for applications where harm to human life and damage to property
must be prevented in the event of fire, e. g. in power stations, industrial installations, communal establishments, hotels, airports, underground stations,
railway stations, hospitals department stores, banks, schools theaters, multi-storey buildings, process control centres etc. Suitable for fixed installation
in dry, damp or wet environments, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor
applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of
Q
water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
J type O type cross-sec. app. mm weight app. J type O type cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
53558 1 x 1,5 rm 6,0 14,4 41,0 16 53114 53262 2 x 1,5 re 12,0 29,0 185,0 16
53559 1 x 2,5 rm 6,5 24,0 53,0 14 53115 53263 2 x 2,5 re 12,2 48,0 220,0 14
53100 53248 1 x 4 re 8,0 39,0 68,0 12 53116 53264 2 x 4 re 13,2 77,0 275,0 12
53101 53249 1 x 6 re 9,0 58,0 90,0 10 53117 53265 2 x 6 re 14,1 115,0 335,0 10
53102 53250 1 x 10 re 9,0 96,0 140,0 8 53118 53266 2 x 10 re 16,2 192,0 450,0 8
53103 53251 1 x 16 re 10,0 154,0 190,0 6 53119 53267 2 x 16 re 17,8 307,0 620,0 6
53104 53252 1 x 25 rm 11,0 240,0 290,0 4 53120 53268 2 x 25 rm 21,0 480,0 930,0 4
53105 53253 1 x 35 rm 12,0 336,0 390,0 2
53106 53254 1 x 50 rm 15,0 480,0 510,0 1
53107 53255 1 x 70 rm 17,0 672,0 710,0 2/0
53108 53256 1 x 95 rm 19,0 912,0 960,0 3/0
53109 53257 1 x 120 rm 21,0 1152,0 1200,0 4/0
53110 53258 1 x 150 rm 23,0 1440,0 1480,0 300 kcmil
53111 53259 1 x 185 rm 25,0 1776,0 1910,0 350 kcmil
53112 53260 1 x 240 rm 28,0 2304,0 2370,0 500 kcmil
53113 53261 1 x 300 rm 30,0 2880,0 2970,0 600 kcmil
52485 52486 1 x 400 rm 32,9 3840,0 3957,0 750 kcmil

Continuation

557
Energy- and Power Cable / Low Voltage and Security Cables

N2XH power cable, 0,6/1 kV, halogen-free, without functionality


Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
J type O type cross-sec. app. mm weight app. J type O type cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
53121 53269 3 x 1,5 re 13,0 43,0 220,0 16 53136 53330 3 x 50 / 25 sm 28,5 1680,0 2100,0 1
53122 53270 3 x 2,5 re 14,0 72,0 280,0 14 53137 53331 3 x 70 / 35 sm 31,4 2352,0 2800,0 2/0
53123 53271 3 x 4 re 15,0 115,0 350,0 12 53138 53332 3 x 95 / 50 sm 34,9 3216,0 3750,0 3/0
53124 53272 3 x 6 re 16,0 173,0 420,0 10 53139 53333 3 x 120 / 70 sm 38,0 4128,0 4750,0 4/0
53125 53273 3 x 10 re 18,0 288,0 600,0 8 53140 53334 3 x 150 / 70 sm 43,3 4992,0 5750,0 300 kcmil
53126 53274 3 x 16 re 20,0 461,0 770,0 6 53141 53335 3 x 185 / 95 sm 47,2 6240,0 7200,0 350 kcmil
53127 53275 3 x 25 rm 21,8 720,0 1120,0 4 53142 53336 3 x 240 / 120 sm 53,4 8064,0 9300,0 500 kcmil
53128 53276 3 x 35 sm 24,9 1008,0 1550,0 2
53129 53277 3 x 50 sm 25,2 1440,0 1750,0 1
53130 53278 3 x 70 sm 29,2 2016,0 2450,0 2/0
53131 53279 3 x 95 sm 32,0 2736,0 3250,0 3/0
53132 53280 3 x 120 sm 34,9 3456,0 4000,0 4/0
53133 53281 3 x 150 sm 39,2 4320,0 5000,0 300 kcmil
53134 53282 3 x 185 sm 44,1 5328,0 6150,0 350 kcmil
53135 53283 3 x 240 sm 49,2 6912,0 8000,0 500 kcmil
53143 53284 4 x 1,5 re 13,0 58,0 235,0 16
53144 53285 4 x 2,5 re 14,0 96,0 290,0 14
53145 53286 4 x 4 re 15,0 154,0 370,0 12
53146 53287 4 x 6 re 16,0 230,0 470,0 10
53147 53288 4 x 10 re 18,0 384,0 670,0 8
53148 53289 4 x 16 re 20,0 614,0 930,0 6
53149 53290 4 x 25 rm 25,0 960,0 1440,0 4
53150 53291 4 x 35 sm 27,0 1344,0 1890,0 2
53151 53292 4 x 50 sm 28,0 1920,0 2300,0 1
53152 53293 4 x 70 sm 32,0 2688,0 3200,0 2/0
53153 53294 4 x 95 sm 36,0 3648,0 4250,0 3/0
53154 53295 4 x 120 sm 40,2 4608,0 5350,0 4/0
53155 53296 4 x 150 sm 45,8 5760,0 6550,0 300 kcmil
53156 53297 4 x 185 sm 49,5 7104,0 8100,0 350 kcmil
53157 53298 4 x 240 sm 56,0 9216,0 10550,0 500 kcmil
53158 53299 5 x 1,5 re 14,5 72,0 280,0 16
53159 53309 5 x 2,5 re 16,0 120,0 350,0 14
53160 53310 5 x 4 re 17,0 192,0 450,0 12
53161 53311 5 x 6 re 18,5 288,0 600,0 10
53162 53312 5 x 10 re 21,0 480,0 850,0 8
53163 53313 5 x 16 re 24,0 768,0 1200,0 6
53557 5 x 25 rm 28,0 1200,0 1539,0 4
53164 53314 7 x 1,5 re 15,5 101,0 350,0 16
53171 53315 7 x 2,5 re 17,0 168,0 370,0 14
53178 53316 7 x 4 re 17,2 269,0 530,0 12
53165 53317 10 x 1,5 re 18,5 144,0 480,0 16
53172 53318 10 x 2,5 re 20,0 240,0 500,0 14
53166 53319 12 x 1,5 re 19,0 173,0 520,0 16
53173 53320 12 x 2,5 re 21,0 288,0 560,0 14
53179 53321 12 x 4 re 21,2 461,0 800,0 12
53167 53322 14 x 1,5 re 20,0 202,0 550,0 16
53174 53323 14 x 2,5 re 22,0 336,0 630,0 14
53168 53324 19 x 1,5 re 22,0 274,0 700,0 16
53175 53325 19 x 2,5 re 24,0 456,0 800,0 14
53169 53326 24 x 1,5 re 25,0 346,0 850,0 16
53176 53327 24 x 2,5 re 27,0 576,0 990,0 14
53170 53328 30 x 1,5 re 26,0 432,0 950,0 16
53177 53329 30 x 2,5 re 28,0 720,0 1180,0 14

Dimensions and specifications may be changed without prior notice. (RQ02)

558
Energy- and Power Cable / Low Voltage and Security Cables

N2XCH power cable, 0,6/1kV, halogen-free, with concentric conductor, without


functionality

Technical data Cable structure Properties


Power and control cable acc. Bare copper-conductor, to Halogen-free, no liberation of
to DIN VDE 0276 part 604, DIN VDE 0295 cl.1 or cl.2, single-wire corrosive or toxic gases
HD 604 S1 part 1 and part 5G or multi-wire, BS 6360 cl.1 or cl.2, Limited propagation of fire
Temperature range IEC 60228 cl.1 or cl.2 Low smoke development
during installation -5C to +50C Core insulation of cross-linked The materials used in manufacture are
fixed installation -30C to +90C polyethylene (XLPE) cadmium-free and contain no silicone
Permissible operating temperature compound type 2XI1 to HD 604 S1 and free from substances harmful to
at conductor +90C Core identification to DIN VDE 0293-308 the wetting properties of lacquers
Nominal voltage U0/U 0,6/1 kV Cores stranded in layers Tests
Test voltage 4 kV (for multi-core cables) Flame test acc. to DIN VDE 0482-332-3-24,
Minimum bending radius Overall filled inner sheat BS 4066 part 3, DIN EN 60332-3-24,
12x cable Covered by filling compound or taping IEC 60332-3-24 (previously DIN VDE 0472
Radiation resistance Concentric conductor of bare Cu-wires part 804 test method C)
up to 100x106 cJ/kg (up to 100 Mrad) Outer sheath of thermoplastic Corrosiveness of combustion gases
Caloric load values polyolefine, compound type HM4 acc. to DIN VDE 0482 part 267,
see Technical Informations to HD 604 S1 DIN EN 50267-2-2, IEC 60754-2
Sheath colour black (equivalent DIN VDE 0472 part 813)
Halogen-free acc. to DIN VDE 0482
part 267, DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
sm = sectional conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen

Application
The power cables with enhanced characteristics in case of fire are used in power stations.
The concentric conductor can be used as a PE or PEN conductor or as screen. Suitable for fixed installation in dry, damp or wet environments, in, above,
on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications and in underground by using
in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC. Q
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
53200 2 x 1,5 / 1,5 re 12,0 53,0 250,0 16 53223 4 x 4 / 4 re 17,5 202,0 480,0 12
53201 2 x 2,5 / 2,5 re 13,0 81,0 280,0 14 53224 4 x 6 / 6 re 19,0 297,0 600,0 10
53202 2 x 4 / 4 re 14,0 122,0 320,0 12 53225 4 x 10 / 10 re 21,5 504,0 850,0 8
53203 2 x 6 / 6 re 15,0 183,0 400,0 10 53226 4 x 16 / 16 re 24,5 797,0 1200,0 6
53204 2 x 10 / 10 re 16,0 311,0 560,0 8 53227 4 x 25 / 16 rm 29,0 1142,0 1800,0 4
53205 2 x 16 / 16 re 19,1 490,0 780,0 6 53228 4 x 35 / 16 rm 29,5 1528,0 2100,0 2
53206 3 x 1,5 / 1,5 re 13,0 67,0 250,0 16 53229 4 x 50 / 25 sm 32,5 2203,0 2800,0 1
53207 3 x 2,5 / 2,5 re 14,0 104,0 320,0 14 53230 4 x 70 / 35 sm 38,0 3082,0 3800,0 2/0
53208 3 x 4 / 4 re 16,5 161,0 400,0 12 53231 4 x 95 / 50 sm 43,5 4208,0 5100,0 3/0
53209 3 x 6 / 6 re 18,0 242,0 500,0 10 53758 4 x 120 / 70 sm 50,5 5388,0 6556,0 4/0
53210 3 x 10 / 10 re 20,0 408,0 750,0 8 53759 4 x 150 / 70 sm 52,1 6540,0 7600,0 300 kcmil
53211 3 x 16 / 16 re 22,5 643,0 1000,0 6 53760 4 x 185 / 95 sm 57,2 8159,0 9370,0 350 kcmil
53212 3 x 25 / 16 rm 27,0 902,0 1600,0 4 53761 4 x 240 / 120 sm 62,6 10546,0 11611,0 500 kcmil
53213 3 x 35 / 16 rm 27,5 1190,0 1900,0 2 53232 7 x 1,5 / 2,5 re 15,0 132,0 320,0 16
53214 3 x 50 / 25 rm 32,3 1723,0 2400,0 1 53239 7 x 2,5 / 2,5 re 15,5 200,0 400,0 14
53215 3 x 70 / 35 sm 35,6 2410,0 3060,0 2/0 53246 7 x 4 / 4 re 18,1 316,0 580,0 12
53216 3 x 95 / 50 sm 39,0 3296,0 4200,0 3/0 53233 10 x 1,5 / 2,5 re 17,2 177,0 420,0 16
53217 3 x 120 / 70 sm 42,0 4236,0 5207,0 4/0 53240 10 x 2,5 / 4 re 18,9 287,0 550,0 14
53218 3 x 150 / 70 sm 43,5 5100,0 5700,0 300 kcmil 53234 12 x 1,5 / 2,5 re 18,4 204,0 460,0 16
53219 3 x 185 / 95 sm 47,4 6383,0 7150,0 350 kcmil 53241 12 x 2,5 / 4 re 19,2 335,0 610,0 14
53220 3 x 240 / 120 sm 53,5 8240,0 9250,0 500 kcmil 53247 12 x 4 / 6 re 22,6 528,0 910,0 12
53221 4 x 1,5 / 1,5 re 13,5 81,0 300,0 16 53235 16 x 1,5 / 4 re 20,0 275,0 686,0 16
53222 4 x 2,5 / 2,5 re 14,5 129,0 380,0 14 53242 16 x 2,5 / 6 re 20,9 450,0 805,0 14

Continuation

559
Energy- and Power Cable / Low Voltage and Security Cables

N2XCH power cable, 0,6/1kV, halogen-free, with concentric conductor, without


functionality
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km
mm kg / km
53236 21 x 1,5 / 6 re 22,6 370,0 766,0 16
53243 21 x 2,5 / 6 re 25,2 572,0 1015,0 14
53237 24 x 1,5 / 6 re 23,2 412,0 800,0 16
53244 24 x 2,5 / 10 re 26,1 695,0 1100,0 14
53238 30 x 1,5 / 6 re 24,3 500,0 930,0 16
53245 30 x 2,5 / 10 re 28,0 842,0 1290,0 14

Dimensions and specifications may be changed without prior notice. (RQ02)

560
Energy- and Power Cable / Low Voltage and Security Cables

(N)A2XH power cable, 0,6/1 kV, halogen-free, without functionality

Technical data Cable structure Properties


Power and control cable adapted to Aluminium-conductor, to DIN VDE 0295 Halogen-free, no separation of corrosive
DIN VDE 0276 part 604, HD 604 S1 cl.1 or cl.2, single-wire or multi-wire, or toxic gases
part 1 and part 5G BS 6360 cl.1 or cl.2, IEC 60228 Limited propagation of fire
Temperature range cl.1 or cl.2 Low smoke development
during installation -5C to +50C Core insulation of cross-linked The materials used in manufacture are
fixed installation -30C to +90C polyethylene (XLPE) cadmium-free and contain no silicone
Permissible operating temperature compound type 2XI1 to HD 604 S1 and free from substances harmful to
at conductor +90C Core identification to DIN VDE 0293-308 the wetting properties of lacquers
Nominal voltage U0/U 0,6/1 kV Core identification for 3+ conductor Tests
Test voltage 4 kV J-type: GN-YE (), BN, BK, GY Flame test acc. to DIN VDE 0482-332-3-24,
Minimum bending radius O-type: BU (), BN, BK, GY BS 4066 part 3, DIN EN 60332-3-24,
single-core 15x cable Cores stranded in layers IEC 60332-3-24 (previously DIN VDE 0472
multi-core 12x cable (for multi-core cables) part 804 test method C)
Radiation resistance Overall filled inner sheath Corrosiveness of combustion gases
up to 100x106 cJ/kg (up to 100 Mrad) Covered by filling compound or taping acc. to DIN VDE 0482 part 267,
Outer sheath of thermoplastic DIN EN 50267-2-2, IEC 60754-2
polyolefine, ompound type HM4 (equivalent DIN VDE 0472 part 813)
to HD 604 S1 Halogen-free acc. to DIN VDE 0482
Sheath colour black part 267, DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Note
rm = round conductor, multi-wire;
se = sector-shaped conductor, single-wire;
sm = sector-shaped conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen

Application
Halogen-free power cables for energy with enhanced characteristics in case of fire are used for applications where harm to human life and damage
to property must be prevented in the event of fire, e. g. in power stations, industrial installations, communal establishments, hotels, airports, underground
stations, railway stations, hospitals department stores, banks, schools theaters, multi-storey buildings, process control centres etc. Suitable for fixed
installation in dry, damp or wet environments, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable
for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no
accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Q
Part no. No.cores x Outer Alu Weight AWG-No. Part no. No.cores x Outer Alu Weight AWG-No.
J type O type cross-sec. app. mm weight app. J type O type cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
50073 50128 1 x 25 rm 9,9 73,0 132,0 4 50083 50137 3 x 16 rm 16,3 139,0 364,0 6
50074 50129 1 x 35 rm 11,0 102,0 166,0 2 50084 50138 3 x 25 rm 19,6 218,0 530,0 4
50075 50130 1 x 50 rm 12,5 145,0 211,0 1 50085 50139 3 x 35 rm 22,1 305,0 684,0 2
50076 50131 1 x 70 rm 14,1 203,0 283,0 2/0 50086 50140 3 x 35 se 19,0 305,0 486,0 2
50077 50132 1 x 95 rm 16,1 276,0 376,0 3/0 50087 50141 3 x 50 sm 22,4 435,0 655,0 1
50078 50133 1 x 120 rm 17,5 348,0 456,0 4/0 50088 50142 3 x 50 se 21,2 435,0 622,0 1
53562 53553 1 x 150 rm 19,6 435,0 560,0 300 kcmil 50089 50143 3 x 70 sm 26,1 609,0 903,0 2/0
50079 50134 1 x 185 rm 21,8 537,0 697,0 350 kcmil 50090 50144 3 x 70 se 25,2 609,0 859,0 2/0
53561 50135 1 x 240 rm 24,0 696,0 878,0 500 kcmil 50091 50145 3 x 95 sm 29,1 827,0 1174,0 3/0
50080 53554 1 x 300 rm 26,7 870,0 1073,0 600 kcmil 50092 50146 3 x 95 se 27,8 827,0 1115,0 3/0
50081 50136 1 x 400 rm 29,7 1160,0 1347,0 750 kcmil 50093 50147 3 x 120 sm 32,2 1044,0 1446,0 4/0
50082 53555 1 x 500 rm 33,1 1450,0 1705,0 1000 50094 50148 3 x 120 se 30,8 1044,0 1379,0 4/0
kcmil

Continuation

561
Energy- and Power Cable / Low Voltage and Security Cables

(N)A2XH power cable, 0,6/1 kV, halogen-free, without functionality


Part no. No.cores x Outer Alu Weight AWG-No. Part no. No.cores x Outer Alu Weight AWG-No.
J type O type cross-sec. app. mm weight app. J type O type cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
50095 50149 3 x 150 sm 36,2 1305,0 1780,0 300 kcmil 50109 50171 4 x 95 sm 33,3 1102,0 1538,0 3/0
50096 50150 3 x 150 se 33,9 1305,0 1685,0 300 kcmil 50110 50172 4 x 95 se 32,1 1102,0 1467,0 3/0
50097 50154 3 x 185 sm 40,1 1610,0 2197,0 350 kcmil 50111 50173 4 x 120 sm 37,2 1392,0 1903,0 4/0
50098 50155 3 x 185 se 37,6 1610,0 2089,0 350 kcmil 50112 50174 4 x 120 se 35,5 1392,0 1817,0 4/0
50099 50156 3 x 240 sm 44,9 2088,0 2782,0 500 kcmil 50113 50175 4 x 150 sm 41,3 1740,0 2328,0 300 kcmil
50100 50157 3 x 240 se 41,8 2088,0 2634,0 500 kcmil 50114 50176 4 x 150 se 39,4 1740,0 2223,0 300 kcmil
50101 50158 3 x 70 / 35 sm 28,3 711,0 1044,0 2/0 50115 50177 4 x 185 sm 45,7 2146,0 2874,0 350 kcmil
50102 50159 3 x 120 / 70 sm 35,1 1247,0 1704,0 4/0 50116 50178 4 x 185 se 43,4 2146,0 2750,0 350 kcmil
53550 50160 3 x 150 / 70 sm 39,7 1508,0 2065,0 300 kcmil 50117 50179 4 x 240 sm 51,2 2784,0 3646,0 500 kcmil
50103 50161 3 x 185 / 95 sm 43,7 1885,0 2563,0 350 kcmil 50118 50180 4 x 240 se 48,0 2784,0 3465,0 500 kcmil
53551 50162 3 x 240 / 120 sm 49,1 2436,0 3237,0 500 kcmil 50119 50181 5 x 25 rm 23,9 362,0 763,0 4
53560 50163 4 x 16 rm 19,0 186,0 460,0 6 50120 50182 5 x 35 rm 27,0 508,0 986,0 2
50104 50164 4 x 25 rm 21,7 290,0 636,0 4 50121 50183 5 x 50 rm 31,3 725,0 1309,0 1
50105 50165 4 x 35 sm 22,4 406,0 649,0 2 50122 50184 5 x 70 rm 35,8 1015,0 1771,0 2/0
50106 50166 4 x 35 se 21,6 406,0 623,0 2 50123 50185 5 x 95 sm 36,5 1378,0 1891,0 3/0
50107 50167 4 x 50 sm 25,4 580,0 845,0 1 50124 50186 5 x 120 sm 39,2 1740,0 2306,0 4/0
53556 50168 4 x 50 se 24,6 580,0 810,0 1 50125 50187 5 x 150 sm 45,4 2175,0 2865,0 300 kcmil
50108 50169 4 x 70 sm 29,7 812,0 1178,0 2/0 50126 50188 5 x 185 sm 50,1 2683,0 3534,0 350 kcmil
53552 50170 4 x 70 se 28,8 812,0 1126,0 2/0 50127 50189 5 x 240 sm 55,2 3480,0 4482,0 500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ02)

562
Energy- and Power Cable / Low Voltage and Security Cables

N2XH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics

Technical data Cable structure Properties


Halogen-free security cable with improved Bare copper-conductor, to Halogen free, no separation of corrosive
characteristics in the case of fire to DIN VDE 0295 cl.1 or cl.2, single-wire and toxic gases
DIN VDE 0266 or multi-wire, BS 6360 cl.1 or cl.2, Flame retardant and hardly flammable
Temperature range IEC 60228 cl.1 or cl.2 Self-extinguished and fire resistant
-30C to +70C Core insulation of cross-linked No flame propagation, therefore security
Permissible operating temperature polyethylene, compound type 2XI1 to from fire
at conductor +90C DIN VDE 0276 part 604 low smoke density, low impairment of
Nominal voltage U0/U 0,6/1 kV Core identification to DIN VDE 0293-308 escape routes and fire extinguishing
Test voltage 4000 V and 0276 part 604 activities
Minimum bending radius GN-YE conductor, 3 cores and above Toxicological harmless
15x cable Cores stranded in layers No self-ignition
Radiation resistance Overall core covering, halogen-free filling Maintenance of functionality during the
up to 200x106 cJ/kg (up to 200 Mrad) compound, pressed increased current load
Caloric load values Outer sheath of thermoplastic halogen-free FE 180: Insulation integrity for 180
see Technical Informations polyolefine, flame retardant minutes. Tests acc.to DIN VDE 0472
Sheath colour orange part 814 IEC 60331.
Tests Insulation integrity under direct
Flame test acc. to flame propagation for the test period
DIN VDE 0482-332-3, BS 4066 part 3, of 180 minutes.
DIN EN 60332-3, IEC 60332-3 (previously E 30: Functionality of electrical cable
DIN VDE 0472 part 804 test method C) systems for minimum 30 minutes. Test to
Corrosiveness of combustion gases DIN 4102 part 12. This fulfils the demands
acc. to DIN VDE 0482 part 267, of technical guide lines for fire protection
DIN EN 50267-2-2, IEC 60754-2 (supplement 1 to DIN VDE 0108 part 1).
(equivalent DIN VDE 0472 part 813) The functionality for 30 minutes assures
Halogen-free acc. to DIN VDE 0482 when persons and animals are to be saved
part 267, DIN EN 50267-2-1, IEC 60754-1 from a burning building. 30 minutes
(equivalent DIN VDE 0472 part 815) secures the functional performance of the
Smoke density acc. to DIN VDE 0482 fire warning and alarm systems, safety and
part 1034-1+2, DIN EN 61034-1+2, spare lighting, passenger lifts with
IEC 61034-1+2, BS 7622 part 1+2 evacuation circuits, except the cables which
(previously DIN VDE 0472 part 816) are installed within the ladder shafts and
engine rooms.

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen
Q
Application
Security cables are ideal for use everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a
special significance, e. g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals
and outpatients clinic (DIN VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings,
schools etc. (DIN VDE 0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems.
The cables are suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete.
For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52058 1 x 4 re 8,0 38,0 155,0 12 52063 1 x 35 rm 14,0 336,0 460,0 2
52059 1 x 6 re 9,0 58,0 190,0 10 52064 1 x 50 rm 15,5 480,0 590,0 1
52060 1 x 10 re 10,0 96,0 215,0 8 52065 1 x 70 rm 17,5 672,0 820,0 2/0
52061 1 x 16 re 10,5 154,0 240,0 6 52066 1 x 95 rm 19,5 912,0 1090,0 3/0
52062 1 x 25 rm 13,0 240,0 380,0 4 52067 1 x 120 rm 21,0 1152,0 1350,0 4/0

Continuation

563
Energy- and Power Cable / Low Voltage and Security Cables

N2XH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52068 1 x 150 rm 23,0 1440,0 1650,0 300 kcmil 52093 3 x 120 / 70 rm 45,0 4128,0 5550,0 4/0
52069 1 x 185 rm 25,0 1776,0 2030,0 350 kcmil 52094 3 x 150 / 70 rm 48,5 4992,0 6560,0 300 kcmil
52070 1 x 240 rm 29,0 2304,0 2590,0 500 kcmil 52095 3 x 185 / 95 rm 54,0 6240,0 8240,0 350 kcmil
52071 2 x 1,5 re 11,5 29,0 170,0 16 52096 4 x 1,5 re 12,5 58,0 210,0 16
52072 2 x 2,5 re 12,0 48,0 190,0 14 52097 4 x 2,5 re 13,0 96,0 260,0 14
52073 2 x 4 re 13,0 77,0 260,0 12 52614 4 x 4 re 13,0 154,0 310,0 12
52074 2 x 6 re 14,0 115,0 310,0 10 52615 4 x 6 re 14,5 230,0 410,0 10
52075 2 x 10 re 15,5 192,0 430,0 8 52616 4 x 10 re 16,0 384,0 620,0 8
52076 2 x 16 re 17,5 307,0 600,0 6 52617 4 x 16 re 18,0 614,0 900,0 6
52077 2 x 25 rm 22,0 480,0 930,0 4 52628 4 x 25 rm 23,6 960,0 1600,0 4
52078 3 x 1,5 re 12,0 43,0 170,0 16 52629 4 x 35 rm 26,4 1344,0 2050,0 2
52079 3 x 2,5 re 12,5 72,0 220,0 14 52383 4 x 50 rm 29,5 1920,0 2761,0 1
52080 3 x 4 re 13,5 115,0 290,0 12 52432 4 x 70 rm 34,6 2688,0 3785,0 2/0
52081 3 x 6 re 14,5 173,0 370,0 10 52433 4 x 95 rm 39,0 3648,0 5010,0 3/0
52082 3 x 10 re 16,5 288,0 530,0 8 52434 4 x 120 rm 43,5 4608,0 6135,0 4/0
52083 3 x 16 re 18,5 461,0 760,0 6 52618 5 x 1,5 re 12,0 72,0 210,0 16
52084 3 x 25 rm 23,5 720,0 1160,0 4 52619 5 x 2,5 re 13,0 120,0 280,0 14
52088 3 x 25 / 16 rm 22,5 874,0 1430,0 4 52620 5 x 4 re 14,5 192,0 380,0 12
52085 3 x 35 rm 26,0 1080,0 1560,0 2 52621 5 x 6 re 15,5 288,0 510,0 10
52089 3 x 35 / 16 rm 28,0 1162,0 1810,0 2 52622 5 x 10 re 18,0 480,0 760,0 8
52086 3 x 50 rm 29,0 1440,0 2030,0 1 52623 5 x 16 re 20,0 768,0 1120,0 6
52090 3 x 50 / 25 rm 32,0 1680,0 2340,0 1 52626 5 x 25 rm 24,5 1200,0 1840,0 4
52087 3 x 70 rm 34,0 2016,0 2890,0 2/0 52627 5 x 35 rm 33,5 1680,0 2510,0 2
52091 3 x 70 / 35 rm 35,0 2352,0 3190,0 2/0 52624 7 x 1,5 re 13,0 101,0 250,0 16
52092 3 x 95 / 50 rm 40,0 3216,0 4350,0 3/0 52625 12 x 1,5 re 16,5 173,0 390,0 16

Dimensions and specifications may be changed without prior notice. (RQ02)

564
Energy- and Power Cable / Low Voltage and Security Cables

N2XCH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved


fire characteristics

Technical data Cable structure Properties


Halogen-free security cable with improved Bare copper-conductor, to Halogen-free; no evolution of corrosive
characteristics in the case of fire to DIN VDE 0295 cl.1 or cl.2, single-wire and toxic gases
DIN VDE 0266 or multi-wire, BS 6360 cl.1 or cl.2, Flame retardant and hardly flammable
Temperature range IEC 60228 cl.1 or cl.2 Self-extinguished and fire resistant
-30C to +70C Core insulation of cross-linked No flame propagation, therefore security
Permissible operating temperature polyethylene, compound type 2XI1 to from fire
at conductor +90C DIN VDE 0276 part 604 Low smoke density, no darkening of
Nominal voltage U0/U 0,6/1 kV Core identification to DIN VDE 0293-308 emergency exits without hindering the fire
Test voltage 4000 V and 0276 part 604 extinguishing works
Minimum bending radius Cores stranded in layers Toxicological harmless
15x cable Overall core covering, halogen-free filling No self-ignition
Radiation resistance compound, pressed Maintenance of functionality during the
up to 200x106 cJ/kg (up to 200 Mrad) Concentric conductor of Cu-bare wires with increased current load
Caloric load values helix of copper tape FE 180: Insulation integrity for 180
see Technical Informations Outer sheath of thermoplastic halogen-free minutes. Tests acc.to DIN VDE 0472
polyolefine, flame retardant part 814 IEC 60331.
Sheath colour orange Insulation integrity under direct
Tests flame propagation for the test period
Flame test acc. to of 180 minutes.
DIN VDE 0482-332-3, BS 4066 part 3, E 30: Functionality of electrical cable
DIN EN 60332-3, IEC 60332-3 (previously systems for minimum 30 minutes. Test
DIN VDE 0472 part 804 test method C) method to DIN 4102 part 12. This fulfils the
Corrosiveness of combustion gases demands of technical guide lines for fire
acc. to DIN VDE 0482 part 267, protection (supplement 1 to DIN VDE 0108
DIN EN 50267-2-2, IEC 60754-2 part 1).
(equivalent DIN VDE 0472 part 813) The functionality for 30 minutes assures
Halogen-free acc. to DIN VDE 0482 when persons and animals are to be saved
part 267, DIN EN 50267-2-1, IEC 60754-1 from a burning building. 30 minutes
(equivalent DIN VDE 0472 part 815) secures the functional performance of the
Smoke density acc. to DIN VDE 0482 fire warning and alarm systems, safety and
part 1034-1+2, DIN EN 61034-1+2, spare lighting, passenger lifts with
IEC 61034-1+2, BS 7622 part 1+2 evacuation circuits, except the cables which
(previously DIN VDE 0472 part 816) are installed within the ladder shafts and
engine rooms.

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Q
LS0H = Low Smoke Zero Halogen

Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications
and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur
in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52098 2 x 1,5 / 1,5 re 13,0 52,0 200,0 16 52101 2 x 6 / 6 re 16,0 182,0 400,0 10
52099 2 x 2,5 / 2,5 re 14,0 80,0 250,0 14 52102 2 x 10 / 10 re 17,5 312,0 570,0 8
52100 2 x 4 / 4 re 15,0 123,0 310,0 12 52103 3 x 1,5 / 1,5 re 13,0 66,0 220,0 16

Continuation

565
Energy- and Power Cable / Low Voltage and Security Cables

N2XCH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved


fire characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52104 3 x 2,5 / 2,5 re 14,0 104,0 270,0 14 52120 4 x 4 / 4 re 17,0 200,0 420,0 12
52105 3 x 4 / 4 re 15,5 161,0 360,0 12 52121 4 x 6 / 6 re 18,0 297,0 540,0 10
52106 3 x 6 / 6 re 16,5 240,0 470,0 10 52122 4 x 10 / 10 re 20,0 504,0 800,0 8
52107 3 x 10 / 10 re 18,5 408,0 680,0 8 52123 4 x 16 / 16 re 22,5 796,0 1150,0 6
52108 3 x 16 / 16 re 21,0 643,0 960,0 6 52124 4 x 25 / 16 rm 28,0 1142,0 1670,0 4
52109 3 x 25 / 16 rm 25,5 902,0 1390,0 4 52125 4 x 35 / 16 rm 30,5 1526,0 2160,0 2
52110 3 x 35 / 16 rm 29,0 1190,0 1720,0 2 52126 4 x 50 / 25 rm 32,0 2203,0 2860,0 1
52111 3 x 50 / 25 rm 31,5 1723,0 2320,0 1 52127 4 x 70 / 35 rm 39,5 3082,0 3980,0 2/0
52112 3 x 70 / 35 rm 36,5 2410,0 3260,0 2/0 52128 4 x 95 / 50 rm 43,5 4208,0 5300,0 3/0
52113 3 x 95 / 50 rm 40,0 3296,0 4310,0 3/0 52129 4 x 120 / 70 rm 49,5 5388,0 6740,0 4/0
52114 3 x 120 / 70 rm 46,0 4236,0 5520,0 4/0 52130 4 x 150 / 70 rm 55,5 6558,0 8210,0 300 kcmil
52115 3 x 150 / 70 rm 50,5 5100,0 6620,0 300 kcmil 52131 4 x 185 / 95 rm 60,0 8159,0 10200,0 350 kcmil
52116 3 x 185 / 95 rm 55,0 6383,0 8180,0 350 kcmil 52132 4 x 240 / 120 rm 68,0 10546,0 12900,0 500 kcmil
52117 3 x 240 / 120 rm 61,5 8242,0 10620,0 500 kcmil 52133 7 x 1,5 / 2,5 re 16,5 133,0 360,0 16
52118 4 x 1,5 / 1,5 re 15,0 81,0 260,0 16 52134 30 x 1,5 / 6 re 29,0 499,0 1070,0 16
52119 4 x 2,5 / 2,5 re 16,0 128,0 310,0 14

Dimensions and specifications may be changed without prior notice. (RQ02)

566
Energy- and Power Cable / Low Voltage and Security Cables

(N)HXH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved


fire characteristics

Technical data Cable structure Properties


Halogen-free security cable with improved Bare copper-conductor, to Halogen-free; no evolution of corrosive
characteristics in the case of fire adapted DIN VDE 0295 cl.1 or cl.2, single-wire and toxic gases
to DIN VDE 0266 or multi-wire, BS 6360 cl.1 or cl.2, Flame retardant and hardly flammable
Temperature range IEC 60228 cl.1 or cl.2 Self-extinguished and fire resistant
-30C to +70C Core insulation of polymer No flame propagation, therefore security
Permissible operating temperature Core identification to DIN VDE 0293-308 from fire
at conductor +90C GN-YE conductor, 3 cores and above Low smoke density, no darkening of
Nominal voltage U0/U 0,6/1 kV Cores stranded in layer emergency exits without hindering the
Test voltage 4000 V Overall core covering fire extinguishing works
Minimum bending radius Outer sheath of polyolefin-compound, Toxicological harmless
15x cable flame retardant No self-ignition
Radiation resistance Sheath colour orange Maintenance of functionality during the
up to 200x106 cJ/kg (up to 200 Mrad) Tests increased current load
Caloric load values Flame test acc. to FE 180: Insulation integrity for 180
see Technical Informations DIN VDE 0482-332-3, BS 4066 part 3, minutes. Tests acc.to DIN VDE 0472
DIN EN 60332-3, IEC 60332-3 (previously part 814 IEC 60331.
DIN VDE 0472 part 804 test method C) Insulation integrity under direct
Corrosiveness of combustion gases flame propagation for the test period
acc. to DIN VDE 0482 part 267, of 180 minutes.
DIN EN 50267-2-2, IEC 60754-2 E 30: Functionality of electrical cable
(equivalent DIN VDE 0472 part 813) systems for minimum 30 minutes. Test to
Halogen-free acc. to DIN VDE 0482 DIN 4102 part 12. This fulfils the demands
part 267, DIN EN 50267-2-1, IEC 60754-1 of technical guide lines for fire protection
(equivalent DIN VDE 0472 part 815) (supplement 1 to DIN VDE 0108 part 1).
Smoke density acc. to DIN VDE 0482 The functionality for 30 minutes assures
part 1034-1+2, DIN EN 61034-1+2, when persons and animals are to be saved
IEC 61034-1+2, BS 7622 part 1+2 from a burning building. 30 minutes
(previously DIN VDE 0472 part 816) secures the functional performance of the
fire warning and alarm systems, safety and
spare lighting, passenger lifts with
evacuation circuits, except the cables which
are installed within the ladder shafts and
engine rooms.

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen
Q
Application
Security cables are ideal for use everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a
special significance, e. g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals
and outpatients clinic (DIN VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings,
schools etc. (DIN VDE 0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems.
The cables are suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete.
These cables are suitable for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must
be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52700 1 x 4 re 7,0 38,0 98,0 12 52707 1 x 70 rm 15,0 672,0 800,0 2/0
52701 1 x 6 re 7,5 58,0 125,0 10 52708 1 x 95 rm 16,5 912,0 1100,0 3/0
52702 1 x 10 re 8,0 96,0 165,0 8 52709 1 x 120 rm 18,5 1152,0 1350,0 4/0
52703 1 x 16 rm 9,0 154,0 230,0 6 52710 1 x 150 rm 20,5 1440,0 1650,0 300 kcmil
52704 1 x 25 rm 10,5 240,0 345,0 4 52711 1 x 185 rm 23,0 1776,0 2000,0 350 kcmil
52705 1 x 35 rm 11,5 336,0 450,0 2 52712 1 x 240 rm 25,5 2304,0 2650,0 500 kcmil
52706 1 x 50 rm 12,0 480,0 590,0 1 52713 1 x 300 rm 31,8 2880,0 3200,0 600 kcmil

Continuation

567
Energy- and Power Cable / Low Voltage and Security Cables

(N)HXH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved


fire characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52714 2 x 2,5 re 12,5 48,0 290,0 14 52748 4 x 150 rm 49,0 5760,0 7650,0 300 kcmil
52715 2 x 4 re 13,5 77,0 345,0 12 52749 5 x 1,5 re 14,0 72,0 375,0 16
52716 2 x 6 re 14,5 115,0 410,0 10 52750 5 x 2,5 re 15,0 120,0 445,0 14
52717 2 x 10 re 16,0 192,0 540,0 8 52751 5 x 4 re 16,5 192,0 560,0 12
52718 2 x 16 rm 18,0 307,0 720,0 6 52752 5 x 6 re 18,0 288,0 690,0 10
52719 2 x 25 rm 21,0 480,0 1100,0 4 52753 5 x 10 re 20,0 480,0 950,0 8
52720 2 x 35 rm 24,0 672,0 1120,0 2 52754 5 x 16 rm 22,5 768,0 1300,0 6
52721 3 x 1,5 re 12,5 43,0 280,0 16 52755 5 x 25 rm 26,5 1200,0 1980,0 4
52722 3 x 2,5 re 13,5 72,0 330,0 14 52756 5 x 35 rm 36,0 1680,0 2600,0 2
52723 3 x 4 re 14,5 115,0 400,0 12 52757 7 x 1,5 re 15,0 101,0 365,0 16
52724 3 x 6 re 15,5 173,0 480,0 10 52758 7 x 2,5 re 16,5 168,0 540,0 14
52725 3 x 10 re 17,0 288,0 650,0 8 52759 10 x 1,5 re 18,0 144,0 580,0 16
52726 3 x 16 rm 19,0 461,0 850,0 6 52760 10 x 2,5 re 20,0 240,0 710,0 14
52727 3 x 25 rm 22,5 720,0 1300,0 4 52761 12 x 1,5 re 19,0 173,0 640,0 16
52728 3 x 35 rm 24,5 1080,0 1700,0 2 52762 12 x 2,5 re 20,5 288,0 790,0 14
52729 3 x 50 rm 27,5 1440,0 2200,0 1 52763 14 x 1,5 re 20,0 202,0 740,0 16
52730 3 x 70 rm 32,0 2016,0 3000,0 2/0 52764 14 x 2,5 re 21,5 336,0 880,0 14
52731 3 x 95 rm 35,5 2736,0 4000,0 3/0 52765 19 x 1,5 re 21,5 274,0 880,0 16
52732 3 x 120 rm 39,5 3456,0 4850,0 4/0 52766 19 x 2,5 re 23,5 456,0 1150,0 14
52733 3 x 150 rm 44,0 4320,0 5950,0 300 kcmil 52767 24 x 1,5 re 25,0 346,0 1100,0 16
52734 3 x 185 rm 49,5 5328,0 7450,0 350 kcmil 52768 24 x 2,5 re 27,0 576,0 1400,0 14
52735 3 x 240 rm 60,0 6910,0 8600,0 500 kcmil 52769 30 x 1,5 re 26,0 432,0 1300,0 16
52736 4 x 1,5 re 13,5 58,0 325,0 16 52770 30 x 2,5 re 28,5 720,0 1650,0 14
52737 4 x 2,5 re 14,0 96,0 385,0 14
52738 4 x 4 re 15,5 154,0 470,0 12
52739 4 x 6 re 16,5 230,0 580,0 10
52740 4 x 10 re 18,5 384,0 790,0 8
52741 4 x 16 rm 20,5 614,0 1100,0 6
52742 4 x 25 rm 24,5 960,0 1650,0 4
52743 4 x 35 rm 27,0 1344,0 2150,0 2
52744 4 x 50 rm 30,0 1920,0 2800,0 1
52745 4 x 70 rm 35,0 2688,0 3800,0 2/0
52746 4 x 95 rm 39,5 3648,0 5050,0 3/0
52747 4 x 120 rm 43,5 4608,0 6150,0 4/0

Dimensions and specifications may be changed without prior notice. (RQ02)

568
Energy- and Power Cable / Low Voltage and Security Cables

(N)HXCH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics

Technical data Cable structure Properties


Halogen-free security cable with improved Bare copper-conductor, to Halogen-free; no evolution of corrosive
characteristics in the case of fire adapted to DIN VDE 0295 cl.1 or cl.2, single-wire and toxic gases
DIN VDE 0266 or multi-wire, BS 6360 cl.1 or cl.2, Flame retardant and hardly flammable
Temperature range IEC 60228 cl.1 or cl.2 Self-extinguished and fire resistant
-30C to +70C Core insulation of polymer No flame propagation, therefore security
Permissible operating temperature Core identification to DIN VDE 0293-308 from fire
at conductor +90C Core stranded in layer Low smoke density, no darkening
Nominal voltage U0/U 0,6/1 kV Overall core covering Toxicological harmless
Test voltage 4000 V Copper wire screening with helix of copper No self-ignition
Minimum bending radius tape Maintenance of functionality during the
15xcable Separator of special tape increased current load
Radiation resistance Outer sheath of polyolefin-compound, FE 180: Insulation integrity for 180
up to 200x106 cJ/kg (up to 200 Mrad) flame retardant minutes. Tests acc.to DIN VDE 0472
Caloric load values Sheath colour orange part 814 IEC 60331.
see Technical Informations Tests Insulation integrity under direct
Flame test acc. to flame propagation for the test period
DIN VDE 0482-332-3, BS 4066 part 3, of 180 minutes.
DIN EN 60332-3, IEC 60332-3 (previously E 30: Functionality of electrical cable
DIN VDE 0472 part 804 test method C) systems for minimum 30 minutes. Test
Corrosiveness of combustion gases method to DIN 4102 part 12. This fulfils
acc. to DIN VDE 0482 part 267, the demands of technical guide lines for
DIN EN 50267-2-2, IEC 60754-2 fire protection (supplement 1 to
(equivalent DIN VDE 0472 part 813) DIN VDE 0108 part 1).
Halogen-free acc. to DIN VDE 0482 The functionality for 30 minutes assures
part 267, DIN EN 50267-2-1, IEC 60754-1 when persons and animals are to be saved
(equivalent DIN VDE 0472 part 815) from a burning building. 30 minutes
Smoke density acc. to DIN VDE 0482 secures the functional performance of the
part 1034-1+2, DIN EN 61034-1+2, fire warning and alarm systems, safety and
IEC 61034-1+2, BS 7622 part 1+2 spare lighting, passenger lifts with
(previously DIN VDE 0472 part 816) evacuation circuits, except the cables which
are installed within the ladder shafts and
engine rooms.

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen Q
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications
and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur
in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52900 2 x 1,5 / 1,5 re 13,0 52,0 220,0 16 52907 3 x 4 / 4 re 15,5 161,0 530,0 12
52901 2 x 2,5 / 2,5 re 13,5 80,0 385,0 14 52908 3 x 6 / 6 re 16,5 240,0 630,0 10
52902 2 x 4 / 4 re 14,5 123,0 470,0 10 52909 3 x 10 / 10 re 18,5 408,0 850,0 8
52903 2 x 6 / 6 re 16,0 182,0 550,0 10 52910 3 x 16 / 16 rm 20,5 643,0 1150,0 6
52904 2 x 10 / 10 re 18,0 312,0 730,0 8 52911 3 x 25 / 16 rm 24,0 902,0 1700,0 4
52905 3 x 1,5 / 1,5 re 13,5 66,0 380,0 16 52912 3 x 35 / 16 rm 26,5 1190,0 2150,0 2
52906 3 x 2,5 / 2,5 re 14,5 104,0 430,0 14 52913 3 x 50 / 25 rm 29,5 1723,0 2800,0 1

Continuation

569
Energy- and Power Cable / Low Voltage and Security Cables

(N)HXCH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52914 3 x 70 / 35 rm 33,0 2410,0 3800,0 2/0 52930 4 x 95 / 50 rm 41,5 4208,0 5750,0 3/0
52915 3 x 95 / 50 rm 37,5 3296,0 5100,0 3/0 52931 4 x 120 / 70 rm 47,0 5388,0 7100,0 4/0
52916 3 x 120 / 70 rm 42,5 4236,0 6250,0 4/0 52932 4 x 150 / 70 rm 52,0 6558,0 8550,0 300 kcmil
52917 3 x 150 / 70 rm 47,0 5100,0 6900,0 300 kcmil 52933 4 x 185 / 95 rm 58,0 8159,0 10700,0 350 kcmil
52918 3 x 185 / 95 rm 52,5 6383,0 8550,0 350 kcmil 52934 4 x 240 / 120 rm 64,0 10546,0 13930,0 500 kcmil
52919 3 x 240 / 120 rm 58,5 8242,0 11150,0 500 kcmil 52935 7 x 1,5 / 2,5 re 16,5 133,0 635,0 16
52920 4 x 1,5 / 1,5 re 14,5 81,0 435,0 16 52936 7 x 2,5 / 2,5 re 17,5 200,0 680,0 14
52921 4 x 2,5 / 2,5 re 15,5 128,0 500,0 14 52937 10 x 1,5 / 2,5 re 19,5 176,0 870,0 16
52922 4 x 4 / 4 re 16,5 200,0 610,0 12 52938 10 x 2,5 / 4 re 21,0 286,0 980,0 14
52923 4 x 6 / 6 re 17,5 297,0 740,0 10 52939 12 x 1,5 / 2,5 re 20,0 205,0 1050,0 16
52924 4 x 10 / 10 re 20,0 504,0 1050,0 8 52940 12 x 2,5 / 4 re 21,5 334,0 1050,0 14
52925 4 x 16 / 16 re 22,0 796,0 1350,0 6 52941 24 x 1,5 / 6 re 26,0 413,0 1900,0 16
52926 4 x 25 / 16 rm 26,0 1142,0 1950,0 4 52942 24 x 2,5 / 10 re 28,5 696,0 1900,0 14
52927 4 x 35 / 16 rm 28,5 1526,0 2400,0 2 52943 30 x 1,5 / 6 re 27,0 499,0 2200,0 16
52928 4 x 50 / 25 rm 32,0 2203,0 3200,0 1 52944 30 x 2,5 / 10 re 30,0 840,0 2200,0 14
52929 4 x 70 / 35 rm 37,0 3082,0 4300,0 2/0

Dimensions and specifications may be changed without prior notice. (RQ02)

570
Energy- and Power Cable / Low Voltage and Security Cables

N2XH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics

Technical data Cable structure Properties


Halogen-free security cable with improved Bare copper-conductor, to Halogen-free; no evolution of corrosive
characteristics in the case of fire to DIN VDE 0295 cl.1 or cl.2, single-wire and toxic gases
DIN VDE 0266 or multi-wire, BS 6360 cl.1 or cl.2, Flame retardant and hardly flammable
Temperature range IEC 60228 cl.1 or cl.2 Self-extinguished and fire resistant
-30C to +70C Core insulation with cross-linked No flame propagation, therefore security
Permissible operating temperature polyethylene, compound type 2XI1 to from fire
at conductor +90C DIN VDE 0276 part 604 Low smoke density, no darkening of
Nominal voltage U0/U 0,6/1 kV Core identification to DIN VDE 0293-308 emergency exits without hindering the fire
Test voltage 4000 V and 0276 part 604 extinguishing works
Minimum bending radius GN-YE conductor, 3 cores and above Toxicological harmless
12x cable Cores stranded in layers No self-ignition
Radiation resistance Overall core covering, halogen-free filling Maintenance of functionality during the
up to 200x106 cJ/kg (up to 200 Mrad) compound, pressed increased current load
Caloric load values Outer sheath of thermoplastic halogen-free FE 180: Insulation integrity for 180
see Technical Informations polyolefine, flame retardant minutes. Tests acc.to DIN VDE 0472
Sheath colour orange part 814 IEC 60331.
Tests Insulation integrity under direct
Flame test acc. to flame propagation for the test period
DIN VDE 0482-332-3, BS 4066 part 3, of 180 minutes.
DIN EN 60332-3, IEC 60332-3 (previously E 90: Functionality of electrical cable
DIN VDE 0472 part 804 test method C) systems for minimum 90 minutes. Test
Corrosiveness of combustion gases method to DIN 4102 part 12. This fulfils the
acc. to DIN VDE 0482 part 267, demands of technical guide lines for fire
DIN EN 50267-2-2, IEC 60754-2 protection (supplement 1 to DIN VDE 0108
(equivalent DIN VDE 0472 part 813) part 1).
Halogen-free acc. to DIN VDE 0482 The functionality for 90 minutes assures
part 267, DIN EN 50267-2-1, IEC 60754-1 the functional performance of
(equivalent DIN VDE 0472 part 815) water-pressure-rising stations for the
Smoke density acc. to DIN VDE 0482 supply to avoid smoke and heat in
part 1034-1+2, DIN EN 61034-1+2, safety-stairs and inner rooms, ladder shafts
IEC 61034-1+2, BS 7622 part 1+2 and engine rooms for fire brigade lifts,
(previously DIN VDE 0472 part 816) emergency lifts for sickbeds in hospitals
and the fire brigade lifts.

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LSOH = Low Smoke Zero Halogen
Q
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications
and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur
in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52534 1 x 16 rm 11,5 154,0 250,0 6 52538 1 x 70 rm 17,5 672,0 840,0 2/0
52535 1 x 25 rm 13,0 240,0 360,0 4 52539 1 x 95 rm 19,5 912,0 1120,0 3/0
52536 1 x 35 rm 14,0 336,0 460,0 2 52540 1 x 120 rm 21,5 1152,0 1390,0 4/0
52537 1 x 50 rm 15,5 480,0 610,0 1 52541 1 x 150 rm 23,5 1440,0 1690,0 300 kcmil

Continuation

571
Energy- and Power Cable / Low Voltage and Security Cables

N2XH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52542 1 x 185 rm 25,5 1776,0 2090,0 350 kcmil 52583 4 x 6 re 19,5 230,0 630,0 10
52899 1 x 240 rm 28,5 2304,0 2660,0 500 kcmil 52584 4 x 10 rm 22,5 384,0 880,0 8
52543 1 x 300 rm 31,0 2880,0 3350,0 600 kcmil 52585 4 x 16 rm 24,5 614,0 1180,0 6
52544 1 x 400 rm 34,5 3840,0 4230,0 750 kcmil 52586 4 x 25 rm 28,5 960,0 1730,0 4
52545 2 x 1,5 re 14,5 29,0 270,0 16 52587 4 x 35 rm 31,0 1344,0 2220,0 2
52546 2 x 2,5 re 15,5 48,0 310,0 14 52588 4 x 50 rm 35,0 1920,0 2940,0 1
52547 2 x 4 re 16,5 77,0 370,0 12 52589 4 x 70 rm 39,0 2688,0 3960,0 2/0
52548 2 x 6 re 17,5 115,0 440,0 10 52590 4 x 95 rm 45,0 3648,0 5360,0 3/0
52549 2 x 10 rm 19,5 192,0 600,0 8 52591 4 x 120 rm 48,5 4608,0 6550,0 4/0
52550 2 x 16 rm 21,0 307,0 780,0 6 52592 4 x 150 rm 54,0 5760,0 8070,0 300 kcmil
52551 2 x 25 rm 23,5 480,0 1100,0 4 52593 4 x 185 rm 59,0 7104,0 9970,0 350 kcmil
52552 2 x 35 rm 26,5 672,0 1400,0 2 52594 4 x 240 rm 66,0 9216,0 12830,0 500 kcmil
52553 2 x 50 rm 30,0 960,0 1830,0 1 52595 5 x 1,5 re 18,0 72,0 420,0 16
52554 2 x 70 rm 33,0 1344,0 2420,0 2/0 52596 5 x 2,5 re 19,0 120,0 500,0 14
52555 2 x 95 rm 37,5 1824,0 3240,0 3/0 52597 5 x 4 re 20,0 192,0 610,0 12
52556 2 x 120 rm 41,0 2304,0 3940,0 4/0 52598 5 x 6 re 21,5 288,0 760,0 10
52557 3 x 1,5 re 15,0 43,0 260,0 16 52599 5 x 10 rm 24,5 480,0 1070,0 8
52558 3 x 2,5 re 16,0 72,0 350,0 14 52600 5 x 16 rm 27,0 768,0 1450,0 6
52559 3 x 4 re 17,0 115,0 420,0 12 52601 5 x 25 rm 31,0 1200,0 2120,0 4
52560 3 x 6 re 18,0 173,0 520,0 10 52602 5 x 35 rm 34,0 1680,0 2730,0 2
52561 3 x 10 rm 20,5 288,0 710,0 8 52603 5 x 50 rm 38,5 2400,0 3620,0 1
52562 3 x 16 rm 22,5 461,0 950,0 6 52604 5 x 70 rm 43,5 3360,0 4940,0 2/0
52563 3 x 25 rm 26,0 720,0 1370,0 4 52605 7 x 1,5 re 19,5 101,0 480,0 16
52564 3 x 35 rm 28,0 1008,0 1750,0 2 52606 7 x 2,5 re 20,5 168,0 580,0 14
52572 3 x 35 / 16 rm 29,5 1162,0 1950,0 2 52607 7 x 4 re 22,0 269,0 730,0 12
52565 3 x 50 rm 32,0 1440,0 2310,0 1 52608 10 x 1,5 re 24,0 144,0 650,0 16
52573 3 x 50 / 25 rm 33,5 1680,0 2640,0 1 52609 10 x 2,5 re 25,5 240,0 790,0 14
52566 3 x 70 rm 35,5 2016,0 3100,0 2/0 52610 12 x 1,5 re 24,5 173,0 720,0 16
52574 3 x 70 / 35 rm 37,0 2352,0 3520,0 2/0 52611 12 x 2,5 re 26,0 288,0 890,0 14
52567 3 x 95 rm 40,5 2736,0 4180,0 3/0 52612 24 x 1,5 re 33,0 346,0 1270,0 16
52575 3 x 95 / 50 rm 42,0 3216,0 4710,0 3/0
52568 3 x 120 rm 44,0 3456,0 5130,0 4/0
52576 3 x 120 / 70 rm 46,5 4128,0 5910,0 4/0
52569 3 x 150 rm 48,5 4320,0 6260,0 300 kcmil
52577 3 x 150 / 70 rm 50,0 4992,0 6970,0 300 kcmil
52570 3 x 185 rm 53,0 5328,0 7720,0 350 kcmil
52578 3 x 185 / 95 rm 55,5 6240,0 8750,0 350 kcmil
52571 3 x 240 rm 59,5 6912,0 9990,0 500 kcmil
52579 3 x 240 / 120 rm 61,5 8064,0 11180,0 500 kcmil
52580 4 x 1,5 re 16,5 58,0 350,0 16
52581 4 x 2,5 re 17,5 96,0 420,0 14
52582 4 x 4 re 18,5 154,0 510,0 12

Dimensions and specifications may be changed without prior notice. (RQ02)

572
Energy- and Power Cable / Low Voltage and Security Cables

N2XCH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics

Technical data Cable structure Properties


Halogen-free security cable with improved Bare copper-conductor, to Halogen-free; no evolution of corrosive
characteristics in the case of fire to DIN VDE 0295 cl.1 or cl.2, single-wire and toxic gases
DIN VDE 0266 or multi-wire, BS 6360 cl.1 or cl.2, Flame retardant and hardly flammable
Temperature range IEC 60228 cl.1 or cl.2 Self-extinguished and fire resistant
-30C to +70C Core insulation with cross-linked No flame propagation, therefore security
Permissible operating temperature polyethylene, compound type 2XI1 to from fire
at conductor +90C DIN VDE 0276 part 604 Low smoke density, no darkening of
Nominal voltage U0/U 0,6/1 kV Core identification to DIN VDE 0293-308 emergency exits without hindering the
Test voltage 4000 V and 0276 part 604 fire extinguishing works
Minimum bending radius Cores stranded in layers Toxicological harmless
12x cable Overall core covering, halogen-free filling No self-ignition
Radiation resistance compound, pressed Maintenance of functionallity during the
up to 200x106 cJ/kg (up to 200 Mrad) Concentric conductor of Cu-bare wires with increased current load
Caloric load values helix of copper tape FE 180: Insulation integrity for 180
see Technical Informations Outer sheath of thermoplastic halogen-free minutes. Tests acc.to DIN VDE 0472
polyolefine, flame retardant part 814 IEC 60331.
Sheath colour orange Insulation integrity under direct
Tests flame propagation for the test period
Flame test acc. to of 180 minutes.
DIN VDE 0482-332-3, BS 4066 part 3, E 90: Functionality of electrical cable
DIN EN 60332-3, IEC 60332-3 (previously systems for minimum 90 minutes. Test
DIN VDE 0472 part 804 test method C) method to DIN 4102 part 12. This fulfils the
Corrosiveness of combustion gases demands of technical guide lines for fire
acc. to DIN VDE 0482 part 267, protection (supplement 1 to DIN VDE 0108
DIN EN 50267-2-2, IEC 60754-2 part 1).
(equivalent DIN VDE 0472 part 813) The functionality for 90 minutes assures
Halogen-free acc. to DIN VDE 0482 the functional performance of
part 267, DIN EN 50267-2-1, IEC 60754-1 water-pressure-rising stations for the
(equivalent DIN VDE 0472 part 815) supply to avoid smoke and heat in
Smoke density acc. to DIN VDE 0482 safety-stairs and inner rooms, ladder shafts
part 1034-1+2, DIN EN 61034-1+2, and engine rooms for fire brigade lifts,
IEC 61034-1+2, BS 7622 part 1+2 emergency lifts for sickbeds in hospitals and
(previously DIN VDE 0472 part 816) the fire brigade lifts.

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LSOH = Low Smoke Zero Halogen
Q
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications
and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur
in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52771 3 x 1,5 / 1,5 re 16,5 66,0 330,0 16 52776 3 x 16 / 16 rm 24,5 643,0 1130,0 6
52772 3 x 2,5 / 2,5 re 17,5 104,0 400,0 14 52777 3 x 25 / 16 rm 28,0 902,0 1560,0 4
52773 3 x 4 / 4 re 18,5 161,0 480,0 12 52778 3 x 35 / 16 rm 30,5 1190,0 1960,0 2
52774 3 x 6 / 6 re 20,0 240,0 600,0 10 52779 3 x 50 / 25 rm 34,0 1723,0 2610,0 1
52775 3 x 10 / 10 rm 22,0 408,0 840,0 8 52780 3 x 70 / 35 rm 37,5 2410,0 3500,0 2/0

Continuation

573
Energy- and Power Cable / Low Voltage and Security Cables

N2XCH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52781 3 x 95 / 50 rm 43,0 3296,0 4700,0 3/0 52795 4 x 70 / 35 rm 41,5 3082,0 4360,0 2/0
52782 3 x 120 / 70 rm 48,0 4236,0 5880,0 4/0 52796 4 x 95 / 50 rm 47,5 4208,0 5900,0 3/0
52783 3 x 150 / 70 rm 52,0 4992,0 7300,0 300 kcmil 52797 4 x 120 / 70 rm 52,5 5388,0 7340,0 4/0
52784 3 x 185 / 95 rm 57,5 6383,0 8760,0 350 kcmil 52798 4 x 150 / 70 rm 57,5 6540,0 8840,0 300 kcmil
52785 3 x 240 / 120 rm 63,5 8242,0 11280,0 500 kcmil 52799 4 x 185 / 95 rm 63,5 8159,0 11020,0 350 kcmil
52786 4 x 1,5 / 1,5 re 17,5 81,0 390,0 16 52800 4 x 240 / 120 rm 70,0 10546,0 14140,0 500 kcmil
52787 4 x 2,5 / 2,5 re 19,0 128,0 470,0 14 52801 7 x 1,5 / 2,5 re 20,5 133,0 520,0 16
52788 4 x 4 / 4 re 20,0 200,0 570,0 12 52805 7 x 2,5 / 2,5 re 22,0 200,0 630,0 14
52789 4 x 6 / 6 re 21,5 297,0 720,0 10 52802 12 x 1,5 / 2,5 re 26,0 205,0 770,0 16
52790 4 x 10 / 10 rm 24,0 504,0 1010,0 8 52806 12 x 2,5 / 4 re 28,0 334,0 950,0 14
52791 4 x 16 / 16 rm 26,5 796,0 1370,0 6 52803 24 x 1,5 / 6 re 35,0 413,0 1380,0 16
52792 4 x 25 / 16 rm 30,5 1142,0 1940,0 4 52807 24 x 2,5 / 10 re 37,5 696,0 1750,0 14
52793 4 x 35 / 16 rm 33,0 1526,0 2420,0 2 52804 30 x 1,5 / 6 re 37,0 499,0 1630,0 16
52794 4 x 50 / 25 rm 37,5 2203,0 3240,0 1 52808 30 x 2,5 / 10 re 39,5 840,0 2080,0 14

Dimensions and specifications may be changed without prior notice. (RQ02)

574
Energy- and Power Cable / Low Voltage and Security Cables

(N)HXH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved


fire characteristics

Technical data Cable structure Properties


Halogen-free security cable with improved Bare copper-conductor, to Halogen-free; no evolution of corrosive
characteristics in the case of fire adapted to DIN VDE 0295 cl.1 or cl.2, single-wire and toxic gases
DIN VDE 0266 or multi-wire, BS 6360 cl.1 or cl.2, Flame retardant and hardly flammable
Temperature range IEC 60228 cl.1 or cl.2 Self-extinguished and fire resistant
-30C to +70C Core insulation of polymer No flame propagation, therefore security
Permissible operating temperature Core identification to DIN VDE 0293-308 from fire
at conductor +90C GN-YE conductor, 3 cores and above Low smoke density, no darkening of
Nominal voltage U0/U 0,6/1 kV Cores stranded in layer emergency exits without hindering the fire
Test voltage 4000 V Core wrapping with glass-fibre tape as extinguishing works
Minimum bending radius flame-protection Toxicological harmless
12x cable Outer sheath of polyolefin-compound, No self-ignition
Radiation resistance flame retardant Maintenance of functionallity during the
up to 200x106 cJ/kg (up to 200 Mrad) Sheath colour orange increased current load
Caloric load values Tests FE 180: Insulation integrity for 180
see Technical Informations Flame test acc. to minutes. Tests acc.to DIN VDE 0472
DIN VDE 0482-332-3, BS 4066 part 3, part 814 IEC 60331.
DIN EN 60332-3, IEC 60332-3 (previously Insulation integrity under direct
DIN VDE 0472 part 804 test method C) flame propagation for the test period
Corrosiveness of combustion gases of 180 minutes.
acc. to DIN VDE 0482 part 267, E 90: Functionality of electrical cable
DIN EN 50267-2-2, IEC 60754-2 systems for minimum 90 minutes. Test
(equivalent DIN VDE 0472 part 813) method to DIN 4102 part 12. This fulfils the
Halogen-free acc. to DIN VDE 0482 demands of technical guide lines for fire
part 267, DIN EN 50267-2-1, IEC 60754-1 protection (supplement 1 to DIN VDE 0108
(equivalent DIN VDE 0472 part 815) part 1).
Smoke density acc. to DIN VDE 0482 The functionality for 90 minutes assures
part 1034-1+2, DIN EN 61034-1+2, the functional performance of
IEC 61034-1+2, BS 7622 part 1+2 water-pressure-rising stations for the
(previously DIN VDE 0472 part 816) supply to avoid smoke and heat in
safety-stairs and inner rooms, ladder shafts
and engine rooms for fire brigade lifts,
emergency lifts for sickbeds in hospitals
and the fire brigade lifts.

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LSOH = Low Smoke Zero Halogen
Q
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications
and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur
in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
53180 1 x 16 rm 11,0 154,0 255,0 6 53188 1 x 185 rm 24,5 1776,0 2140,0 350 kcmil
53181 1 x 25 rm 12,5 240,0 375,0 4 53189 1 x 240 rm 27,0 2304,0 2700,0 500 kcmil
53182 1 x 35 rm 13,5 336,0 475,0 2 53190 1 x 300 rm 30,0 2880,0 3420,0 600 kcmil
53183 1 x 50 rm 15,0 480,0 625,0 1 53191 1 x 400 rm 33,5 3840,0 4310,0 750 kcmil
53184 1 x 70 rm 16,5 672,0 855,0 2/0 53000 3 x 1,5 re 14,0 43,0 280,0 16
53185 1 x 95 rm 18,0 912,0 1140,0 3/0 53001 3 x 2,5 re 15,0 72,0 330,0 14
53186 1 x 120 rm 20,5 1152,0 1410,0 4/0 53002 3 x 4 re 16,0 115,0 400,0 12
53187 1 x 150 rm 22,5 1440,0 1730,0 300 kcmil 53003 3 x 6 re 17,0 173,0 480,0 10

Continuation

575
Energy- and Power Cable / Low Voltage and Security Cables

(N)HXH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved


fire characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
53004 3 x 10 re 19,0 288,0 650,0 8 53070 4 x 120 rm 47,0 4608,0 6150,0 4/0
53005 3 x 16 re 21,0 461,0 850,0 6 53390 4 x 150 rm 51,2 5760,0 7662,0 4/0
52990 3 x 25 rm 25,0 720,0 1300,0 4 53015 5 x 1,5 re 16,0 72,0 375,0 16
52991 3 x 35 rm 28,0 1008,0 1700,0 2 53016 5 x 2,5 re 17,0 120,0 445,0 14
52992 3 x 35 / 16 rm 28,0 1162,0 1850,0 2 53017 5 x 4 re 18,0 192,0 560,0 12
52993 3 x 50 / 25 rm 32,0 1680,0 2500,0 1 53018 5 x 6 re 20,0 288,0 690,0 10
52994 3 x 70 / 35 rm 36,0 2352,0 3350,0 2/0 53019 5 x 10 re 22,0 480,0 950,0 8
52995 3 x 95 / 50 rm 42,0 3216,0 4500,0 3/0 53020 5 x 16 rm 24,0 768,0 1300,0 6
52996 3 x 120 / 70 rm 45,0 4128,0 5600,0 4/0 53021 5 x 25 rm 29,0 1200,0 1980,0 4
52997 3 x 150 / 70 rm 49,0 4992,0 6700,0 300 kcmil 53028 5 x 35 rm 33,0 1680,0 2350,0 2
52998 3 x 185 / 95 rm 55,0 6240,0 8350,0 350 kcmil 53029 5 x 50 rm 38,0 2500,0 3100,0 1
52999 3 x 240 / 120 rm 63,0 8064,0 10000,0 500 kcmil 53022 7 x 1,5 re 19,0 101,0 560,0 16
53006 4 x 1,5 re 15,0 58,0 325,0 16 53027 7 x 2,5 re 21,0 168,0 650,0 14
53007 4 x 2,5 re 16,0 96,0 385,0 14 53025 10 x 1,5 re 23,0 144,0 750,0 16
53008 4 x 4 re 17,0 154,0 470,0 12 53026 10 x 2,5 re 25,0 240,0 910,0 14
53009 4 x 6 re 18,0 230,0 580,0 10 53023 12 x 1,5 re 25,0 173,0 850,0 16
53010 4 x 10 re 20,0 384,0 790,0 8 53024 12 x 2,5 re 26,0 288,0 1000,0 14
53011 4 x 16 re 22,0 614,0 1100,0 6
53012 4 x 25 rm 27,0 960,0 1650,0 4
53013 4 x 35 rm 30,0 1344,0 2150,0 2
53014 4 x 50 rm 34,0 1920,0 2800,0 1
53030 4 x 70 rm 39,0 2688,0 3800,0 2/0
53031 4 x 95 rm 44,0 3648,0 5050,0 3/0

Dimensions and specifications may be changed without prior notice. (RQ02)

576
Energy- and Power Cable / Low Voltage and Security Cables

(N)HXCH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved


fire characteristics

Technical data Cable structure Properties


Halogen-free security cable with Bare copper-conductor, to Halogen-free; no evolution of corrosive
improved characteristics in the DIN VDE 0295 cl.1 or cl.2, single-wire and toxic gases
case of fire adapted to DIN VDE 0266 or multi-wire, BS 6360 cl.1 or cl.2, Flame retardant and hardly flammable
Temperature range IEC 60228 cl.1 or cl.2 Self-extinguished and fire resistant
-30C to +70C Core insulation of polymer No flame propagation, therefore security
Permissible operating temperature Each single core covering with flame from fire
at conductor +90C resistant glass-fibre tape Low smoke density, no darkening of
Nominal voltage U0/U 0,6/1 kV Core identification to DIN VDE 0293-308 emergency exits without hindering the fire
Test voltage 4000 V Cores stranded in layer extinguishing works
Minimum bending radius Core wire screening with helix of copper Toxicological harmless
12x cable tape No self-ignition
Radiation resistance Bare copper wire screening with helix of Maintenance of functionallity during the
up to 200x106 cJ/kg (up to 200 Mrad) copper tape increased current load
Caloric load values Outer sheath of polyolefin-compound, FE 180: Insulation integrity for 180
see Technical Informations flame ratardant minutes. Tests acc.to DIN VDE 0472
Sheath colour orange part 814 IEC 60331.
Tests Insulation integrity under direct
Flame test acc. to flame propagation for the test period
DIN VDE 0482-332-3, BS 4066 part 3, of 180 minutes.
DIN EN 60332-3, IEC 60332-3 (previously E 90: Functionality of electrical cable
DIN VDE 0472 part 804 test method C) systems for minimum 90 minutes. Test
Corrosiveness of combustion gases method to DIN 4102 part 12. This fulfils
acc. to DIN VDE 0482 part 267, the demands of technical guide lines for
DIN EN 50267-2-2, IEC 60754-2 fire protection (supplement 1 to
(equivalent DIN VDE 0472 part 813) DIN VDE 0108 part 1).
Halogen-free acc. to DIN VDE 0482 The functionality for 90 minutes assures
part 267, DIN EN 50267-2-1, IEC 60754-1 the functional performance of
(equivalent DIN VDE 0472 part 815) water-pressure-rising stations for the
Smoke density acc. to DIN VDE 0482 supply to avoid smoke and heat in
part 1034-1+2, DIN EN 61034-1+2, safety-stairs and inner rooms, ladder shafts
IEC 61034-1+2, BS 7622 part 1+2 and engine rooms for fire brigade lifts,
(previously DIN VDE 0472 part 816) emergency lifts for sickbeds in hospitals
and the fire brigade lifts.

Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LSOH = Low Smoke Zero Halogen
Q
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. For the installation in conduit all precautions
must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
59028 2 x 2,5 / 2,5 re 16,0 80,0 390,0 14 53041 3 x 70 / 35 rm 38,0 2410,0 3800,0 2/0
53032 3 x 1,5 / 1,5 re 16,9 66,0 380,0 16 53042 3 x 95 / 50 rm 44,0 3296,0 5100,0 3/0
53033 3 x 2,5 / 2,5 re 18,0 104,0 430,0 14 53043 3 x 120 / 70 rm 47,0 4236,0 6250,0 4/0
53034 3 x 4 / 4 re 19,0 161,0 530,0 12 53044 3 x 150 / 70 rm 51,0 4992,0 6900,0 300 kcmil
53035 3 x 6 / 6 re 20,1 240,0 640,0 10 53045 3 x 185 / 95 rm 56,0 6383,0 8550,0 350 kcmil
53036 3 x 10 / 10 re 22,0 408,0 850,0 8 53046 3 x 240 / 120 rm 65,0 8242,0 11150,0 500 kcmil
53037 3 x 16 / 16 rm 24,0 643,0 1150,0 6
53038 3 x 25 / 16 rm 28,0 902,0 1700,0 4
53039 3 x 35 / 16 rm 30,0 1190,0 2150,0 2
53040 3 x 50 / 25 rm 34,0 1723,0 2800,0 1

Continuation

577
Energy- and Power Cable / Low Voltage and Security Cables

(N)HXCH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved


fire characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
53047 4 x 1,5 / 1,5 re 18,0 81,0 435,0 16 53066 7 x 2,5 / 2,5 re 21,0 200,0 680,0 14
53048 4 x 2,5 / 2,5 re 18,9 128,0 500,0 14 53063 12 x 1,5 / 2,5 re 27,0 205,0 1050,0 16
53049 4 x 4 / 4 re 20,0 200,0 610,0 12 53067 12 x 2,5 / 4 re 28,0 334,0 1050,0 14
53050 4 x 6 / 6 re 21,0 297,0 740,0 10 53064 24 x 1,5 / 6 re 37,0 413,0 1900,0 16
53051 4 x 10 / 10 re 23,0 504,0 1050,0 8 53068 24 x 2,5 / 10 re 37,5 696,0 1900,0 14
53052 4 x 16 / 16 rm 25,0 796,0 1350,0 6 53065 30 x 1,5 / 6 re 39,0 499,0 2200,0 16
53053 4 x 25 / 16 rm 30,0 1142,0 1950,0 4 53069 30 x 2,5 / 10 re 39,5 840,0 2200,0 14
53054 4 x 35 / 16 rm 33,0 1526,0 2400,0 2
53055 4 x 50 / 25 rm 37,0 2203,0 3200,0 1
53056 4 x 70 / 35 rm 42,0 3082,0 4300,0 2/0
53057 4 x 95 / 50 rm 47,0 4208,0 5750,0 3/0
53058 4 x 120 / 70 rm 51,0 5388,0 7100,0 4/0
53059 4 x 150 / 70 rm 56,0 6540,0 8550,0 300 kcmil
53060 4 x 185 / 95 rm 68,0 8159,0 10700,0 350 kcmil
53061 4 x 240 / 120 rm 70,0 10546,0 13930,0 500 kcmil
53062 7 x 1,5 / 2,5 re 21,0 133,0 680,0 16

Dimensions and specifications may be changed without prior notice. (RQ02)

578
Energy- and Power Cable / Low Voltage and Security Cables

JE-H(St)H Bd FE 180/E 30 up to E 90 (orange), halogen-free

Technical data Cable structure Properties


Flame retardant, halogen-free Bare copper-conductor, single-wire No fire propagation
installation cable adapted to Core insulation halogen-free, cross-linked Low smoke density
DIN VDE 0815 polymer, compound type HI1 flame retardant Not for purposes of high current
Loop resistance (E90 with special foil wrapping over and power installation as well as
max. 73,2 Ohm/km conductor) underground laying.
Temperature range Core identification with colour rings and FE 180: Insulation integrity for 180
flexing -5C to +50C ring-groups to DIN VDE 0815 minutes. Tests acc.to DIN VDE 0472
fixed installation -30C to +70C Cores twisted to pairs, 4 pairs consist to part 814 IEC 60331.
Operating peak voltage unit, several units stranded to layers Insulation integrity under direct
225 V (not for purposes of Units identified by numbered tape flame propagation for the test period
high current and power installation) Core wrapping with special polyester and of 180 minutes.
Test voltage glass-fibre tape E 30: Functionality of electrical cable
core/core 500 V Screening with alu-laminated polyester tape systems for minimum 30 minutes. Test to
core/screen 2000 V and solid tinned copper drain wire DIN 4102 part 12.
Insulation resistance 0,8 mm The functionality for 30 minutes assures
min. 100 MOhm x km Outer sheath halogen-free, flame retardant when persons and animals are to be saved
Mutual capacitance to DIN VDE 0207 part 24 HM2 from a burning building. 30 minutes secures
max. 120 nF/km at 800 Hz Sheath colour orange the functional performance of the fire
(this values may be extended at Tests warning and alarm systems, safety and
20% with a make-up up to 4 pairs) Flame test acc. to DIN VDE 0482-332-3, spare lighting, passenger lifts with
Capacitance unbalance BS 4066 part 3, DIN EN 60332-3, evacuation circuits, except the cables which
max. 200 pF/100 m IEC 60332-3 (previously DIN VDE 0472 are installed within the ladder shafts and
(20% of the values, but one part 804 test method C) engine rooms.
value up to 400 pF is allowed) Corrosiveness of combustion gases E 90: Functionality of electrical cable
Minimum bending radius acc. to DIN VDE 0482 part 267, systems for minimum 90 minutes. Test
6x cable DIN EN 50267-2-2, IEC 60754-2 method to DIN 4102 part 12.
Radiation resistance (equivalent DIN VDE 0472 part 813) The functionality for 90 minutes assures
up to 100x106 cJ/kg (up to 100 Mrad) Smoke density acc. to DIN VDE 0482 the functional performance of
Caloric load values part 1034-1+2, DIN EN 61034-1+2, water-pressure-rising stations for the
see Technical Informations IEC 61034-1+2, BS 7622 part 1+2 supply to avoid smoke and heat in
(previously DIN VDE 0472 part 816) safety-stairs and inner rooms, ladder shafts
and engine rooms for fire brigade lifts,
Note emergency lifts for sickbeds in hospitals
E 30 to E 90 and the fire brigade lifts.
Functionality (burning behaviour) is
dependant on corresponding installation
technique.
LS0H = Low Smoke Zero Halogen

Application
Flame resistant, halogen-free, static screened installation cables for telecommunication purpose. The static screen prevents strong interference impulse.
Q
Suitable for fixed installation everywhere, where in case of fire human life and material assets are to be protected and a safety conciousness take a
special significance, e. g. in industrial complexes, public buildings, hotels, airports, under ground railway networks, hospitals.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Functionality E 30 to E 90 Functionality E 30
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
34081 2 x 2 x 0,8 7,4 25,0 74,0 - 34148 2 x 2 x 0,8 7,5 25,0 74,0 -
34082 4 x 2 x 0,8 10,8 45,0 127,0 - 34149 4 x 2 x 0,8 9,3 45,0 127,0 -
34083 8 x 2 x 0,8 16,9 85,0 300,0 - 34150 8 x 2 x 0,8 11,4 85,0 300,0 -
34084 12 x 2 x 0,8 18,5 126,0 336,0 - 34151 12 x 2 x 0,8 13,0 126,0 336,0 -
34085 16 x 2 x 0,8 20,1 166,0 426,0 - 34152 16 x 2 x 0,8 15,7 166,0 426,0 -
34086 20 x 2 x 0,8 22,2 206,0 529,0 - 34153 20 x 2 x 0,8 16,5 206,0 529,0 -
34087 32 x 2 x 0,8 29,1 326,0 859,0 - 34154 32 x 2 x 0,8 20,3 326,0 859,0 -
34088 40 x 2 x 0,8 34,2 407,0 1094,0 - 34155 40 x 2 x 0,8 23,4 407,0 1094,0 -
34089 52 x 2 x 0,8 37,3 529,0 1280,0 - 34156 52 x 2 x 0,8 25,2 529,0 1280,0 -

Dimensions and specifications may be changed without prior notice. (RQ02)

579
Energy- and Power Cable / Low Voltage and Security Cables

JE-H(St)H Bd fire warning cable, FE 180/E 30 to E 90 (red), halogen-free

Technical data Cable structure Properties


Flame retardant, halogen-free Bare copper-conductor, single-wire No fire propagation
installation cable, adapted to Core insulation halogen-free, cross-linked Low smoke density
DIN VDE 0815 polymer HI1, flame retardant (E90 with Not for purposes of high current
Loop resistance special foil wrapping over and power installation as well as
max. 73,2 Ohm/km conductor) underground laying
Temperature range Core identification with colour rings and FE 180: Insulation integrity for 180
flexing -5C to +50C ring-groups to DIN VDE 0815 minutes. Tests acc.to DIN VDE 0472
fixed installation -30C to +70C Cores twisted to pairs, each 4 pairs consist part 814 IEC 60331.
Operating peak voltage to unit, several units stranded to layers Insulation integrity under direct
225 V (not for purposes of Units identified with numbered tape flame propagation for the test period
high current and power installation) Core wrapping with special polyester and of 180 minutes.
Test voltage glass-fibre tape E 30: Functionality of electrical cable
core/core 500 V Screening with alu-laminated polyester tape systems for minimum 30 minutes. Test to
core/screen 2000 V and solid copper drain wire 0,8 mm DIN 4102 part 12.
Insulation resistance Outer sheath halogen-free, flame retardant The functionality for 30 minutes assures
min. 100 MOhm x km to DIN VDE 0207 part 24, HM2 when persons and animals are to be saved
Mutual capacitance Sheath colour red, RAL 3000 with imprint from a burning building. 30 minutes
max. 120 nF/km at 800 Hz "BRANDMELDEKABEL" secures the functional performance of the
(this values may be extended at Tests fire warning and alarm systems, safety and
20% with a make-up up to 4 pairs) Flame test acc. to spare lighting, passenger lifts with
Capacitance unbalance DIN VDE 0482-332-3, BS 4066 part 3, evacuation circuits, except the cables which
max. 200 pF/100 m (20% of the values, but DIN EN 60332-3, IEC 60332-3 (previously are installed within the ladder shafts and
one value up to 400 pF is allowed) DIN VDE 0472 part 804 test method C) engine rooms.
Minimum bending radius Corrosiveness of combustion gases E 90: Functionality of electrical cable
6x cable acc. to DIN VDE 0482 part 267, systems for minimum 90 minutes. Test
Radiation resistance DIN EN 50267-2-2, IEC 60754-2 method to DIN 4102 part 12.
up to 100x106 cJ/kg (up to 100 Mrad) (equivalent DIN VDE 0472 part 813) The functionality for 90 minutes assures
Caloric load values Smoke density acc. to DIN VDE 0482 the functional performance of
see Technical Informations part 1034-1+2, DIN EN 61034-1+2, water-pressure-rising stations for the
IEC 61034-1+2, BS 7622 part 1+2 supply to avoid smoke and heat in
(previously DIN VDE 0472 part 816) safety-stairs and inner rooms, ladder shafts
and engine rooms for fire brigade lifts,
Note emergency lifts for sickbeds in hospitals
E 30 to E 90 and the fire brigade lifts.
Functionality (burning behaviour) is
dependant on corresponding installation
technique.
LS0H = Low Smoke Zero Halogen

Application
Static screened installation cables for telecommunication purposes. The static screen prevents strong interference impulse. Suitable for fixed installation
everywhere, where in case of fire human life and material assets are to be protected and a safety conciousness take a special significance, e. g. in
industrial complexes, public buildings, hotels, airports, under ground railway networks, hospitals.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Functionality E 30 to E 90 Functionality E 30
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
34091 2 x 2 x 0,8 7,4 25,0 74,0 - 34157 2 x 2 x 0,8 7,5 25,0 67,0 -
34092 4 x 2 x 0,8 10,8 45,0 127,0 - 34158 4 x 2 x 0,8 9,3 45,0 103,0 -
34093 8 x 2 x 0,8 16,9 85,0 300,0 - 34159 8 x 2 x 0,8 11,4 85,0 168,0 -
34094 12 x 2 x 0,8 18,5 126,0 336,0 - 34160 12 x 2 x 0,8 13,0 126,0 237,0 -
34095 16 x 2 x 0,8 20,1 166,0 426,0 - 34161 16 x 2 x 0,8 15,7 166,0 303,0 -
34096 20 x 2 x 0,8 22,2 206,0 529,0 - 34162 20 x 2 x 0,8 16,5 206,0 361,0 -
34097 32 x 2 x 0,8 29,1 326,0 859,0 - 34163 32 x 2 x 0,8 20,3 326,0 553,0 -
34098 40 x 2 x 0,8 34,2 407,0 1094,0 - 34164 40 x 2 x 0,8 23,4 407,0 699,0 -
34099 52 x 2 x 0,8 37,3 529,0 1280,0 - 34165 52 x 2 x 0,8 25,2 529,0 865,0 -

Dimensions and specifications may be changed without prior notice. (RQ02)

580
Energy- and Power Cable / Low Voltage and Security Cables

JE-H(St)HRH Bd fire warning cable, FE 180/E 30 to E 90, halogen-free

Technical data Cable structure Properties


Special insulation for cores and outer Bare copper-conductor, single-wire No fire propagation
sheath adapted to DIN VDE 0815. Core insulation of cross-linked Low smoke density
Loop resistance polymer, compound type HI1 with Not for purposes of high current
max. 73,2 Ohm/km mica tape, flame retardant and power installation as well as
Temperature range Core identification with colour rings and underground laying
flexing -5C to +50C ring-groups to DIN VDE 0815 FE 180: Insulation integrity for 180
fixed installation -30C to +70C Cores twisted to pairs, each 4 pairs consist minutes. Tests acc.to DIN VDE 0472
Operating peakvoltage to unit, several units stranded to layers part 814 IEC 60331.
max. 225 V (not for purposes of high Units identified with numbered tape Insulation integrity under direct
current and power installation) Glass-fibre taped flame propagation for the test period
Test voltage Screening with alu-laminated polyester tape of 180 minutes.
core/core 500 V solid copper drain wire 0,8 mm E 30: Functionality of electrical cable
core/screen 2000 V Inner sheath, flame retardant polyolefin systems for minimum 30 minutes. Test to
Insulation resistance compound to DIN VDE 0207 part 24 HM3 DIN 4102 part 12.
min. 100 MOhm x km Galvanized steel wire braided screen The functionality for 30 minutes assures
Mutual capacitance Outer sheath of polyolefin when persons and animals are to be saved
max. 120 nF/km at 800 Hz compound type HM2 from a burning building. 30 minutes
Minimum bending radius to DIN VDE 0207 part 24 secures the functional performance of the
6x cable Outer sheath red (RAL 3000) with imprint fire warning and alarm systems, safety and
Caloric load values "BRANDMELDEKABEL" spare lighting, passenger lifts with
see Technical Informations Tests evacuation circuits, except the cables which
Flame test acc. to are installed within the ladder shafts and
DIN VDE 0482-332-3, BS 4066 part 3, engine rooms.
DIN EN 60332-3, IEC 60332-3 (previously E 90: Functionality of electrical cable
DIN VDE 0472 part 804 test method C) systems for minimum 90 minutes. Test
Corrosiveness of combustion gases method to DIN 4102 part 12.
acc. to DIN VDE 0482 part 267, The functionality for 90 minutes assures
DIN EN 50267-2-2, IEC 60754-2 the functional performance of
(equivalent DIN VDE 0472 part 813) water-pressure-rising stations for the
Smoke density acc. to DIN VDE 0482 supply to avoid smoke and heat in
part 1034-1+2, DIN EN 61034-1+2, safety-stairs and inner rooms, ladder shafts
IEC 61034-1+2, BS 7622 part 1+2 and engine rooms for fire brigade lifts,
(previously DIN VDE 0472 part 816) emergency lifts for sickbeds in hospitals
and the fire brigade lifts.
Note
E 30 to E 90
Functionality is dependant on installation
technique.
LS0H = Low Smoke Zero Halogen

Application Q
Wherever necessary to prevent high property value in case of fire damage to human and material. The static screen prevents strong interference
impulse. Suitable for fixed installation everywhere, where in case of fire human life and material assets are to be protected and a safety conciousness
take a special significance, e. g. in industrial complexes, public buildings, hotels, airports, under ground railway networks, hospitals.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
34075 2 x 2 x 0,8 11,7 25,0 150,0 - 34080 20 x 2 x 0,8 28,9 206,0 870,0 -
34076 4 x 2 x 0,8 15,7 45,0 275,0 - 34072 32 x 2 x 0,8 41,1 326,0 1360,0 -
34077 8 x 2 x 0,8 21,6 85,0 545,0 - 34073 40 x 2 x 0,8 42,3 407,0 1800,0 -
34078 12 x 2 x 0,8 23,8 126,0 602,0 - 34074 52 x 2 x 0,8 45,2 529,0 2038,0 -
34079 16 x 2 x 0,8 27,7 166,0 734,0 -

Dimensions and specifications may be changed without prior notice. (RQ02)

581
MEDIUM-VOLTAGE CABLES

582
MEDIUM VOLTAGE POWER CABLES
XLPE-insulated 6/10 kV, 12/20 kV, 18/30 kV

Since about 1970 the cross-linked polyethylene Insulation


(XLPE)-insulated power cables have been used in Cross-linked polyethylene (XLPE), compound
Germany. The XLPE-insulation possesses very good type DIX8 according to HD 620 S2.
electrical, mechanical and thermal characteristics in Insulation nominal wall-thickness
medium voltage networks. This type of insulation is very for 6/10 kV = 3,4 mm
chemically resistant and also resistant to cold. Due to 12/20 kV = 5,5 mm
various advantages, the XLPE-insulated type has vastly 18/30 kV = 8,0 mm
displaced the traditional classical paper-insulated types
in many sectors. Outer semi-conducting layer
In order to prevent the penetration of moisture and Outer semi-conducting layer is extruded together
also to extend the duration of life, the XLPE-insulated with the inner semi-conducting layer and the
medium voltage cables are designed with longitudinally insulation in one working process and are spliced
water-proof screen including an additional swell tape with each other.
and a PE outer sheath. Semi-conducting compound, cross-linked,
The manufacture of this sheath is based on high density wall-thickness 0,3 to 0,6 mm.
polyethylene (HDPE), in which an additive organic
peroxide is mixed. Due to the heating and pressure the Concentricity of conductor
molecule chains are joined to each other, assuring the The difference between the maximum and
transition from thermoplastic to elastic condition. mini-mum value of 0,5 mm should not be
In comparison to PVC and paper-insulated cables, the exceeded.
advantage of XLPE-insulated medium voltage power
cables is that they possess a low dielectric factor, such as Semi-conducting type
it is 100 times smaller than of PVC-insulated cables. Over the outer semi-conducting layer, a semi-
Moreover, a better dielectric constant value has an conducting tape must be used.
effect on the low mutual capacitance, the short-circuit
to ground and the charging current of XLPE-insulated Screen
cables. Screening of copper wires must have a minimum
diameter of 0,5 mm and over that a copper tape
The good properties of XLPE-insulated cables remain
applied helically with a minimum thickness of
constant through a wide temperature range.
0,1 mm.
Copper cross-section according to HD 620 S2.
Characteristics of XLPE
permissible operating temperature Separator
For permanent (normal) operation + 90C Over the screen as well as under outer sheath,
In short circuit +250C a separating layer must be used (e. g. taping).
In overload operation and
damage by sea up to +130C Outer sheath

Specific heat resistance 3,5 K m/W PE compound DMP2 according to HD 620 S2 black or
PVC compound DMV6 according to HD 620 S2 red
Q
Dielectric constant 2,4
Specific resistance (20C) min. 1016 Ohm cm Wall-thickness = 2,5 mm,
Loss factor (tan ) (20C) max. 0,5 103 for 1x 500 mm2 /30 kV = 2,6 mm
Density 0,92 g/cm3
Breaking strength min. 200%
Tensile strength min. 12,5 N/mm2

Conductor
Copper or aluminium, round, multiwire stranded
and compact, according to VDE 0295.

Inner semi-conducting layer


Semi-conducting compound, cross-linked,
mini-mum wall-thickness 0,3 mm.
Continuation

583
MEDIUM VOLTAGE POWER CABLES
XLPE-insulated 6/10 kV, 12/20 kV, 18/30 kV

Laying of Cable Laying in conduits


In order to avoid any damage, the XLPE-insulated Cables for conduit systems laying in earth, a reduction of
medium voltage cables should carefully laid and the current carrying capacity with a factor of
installed. It must be ensured that the cables should not 0,85 is recommended.
be pulled over the hard or sharp edges.
The cable ends must be water-tight-sealed. Test voltages
After cutting the length both ends must be
sealed immediately. Kind of Voltage test in kV
A laying depth of 60 to 80 cm is recommended. Single voltage test
conductor cables are normally arranged in a trefoil

U0/U = 12/20 kV

U0/U = 18/30 kV
U0/U = 6/10 kV
touching or triangular shape.
For laying in conduits, the influence of thermal
insulation of air space between the cable and the inner
wall of conduit should be specially considered. The inner
diameter of the conduit should be at least 1,5 times that
of the diameter of the cable.
Voltage test a. c. in kV 15 30 45
Bending radius
During the laying of XLPE cables, the bending radius Voltage test d. c. in kV 48 96 144
should not be below of the following values:
Cable without metal sheath = 15 x cable
Cable with Alu-laminated sheath = 30 x cable Voltage test a. c. 18 36 54
(voltage test = 1000 h)
Temperature range
During the installation, the temperature should not be
below the following values: Voltage test to cable system
for XLPE-insulation + PVC sheath = 5C
for XLPE-insulation + PE sheath = 20C During the operation or after laying the medium
voltage power cables, the dielectric can be tested with
Max. permissible tensile strength alternating or direct current. The test duration continues
30 minutes.
By pulling the conductors with a pulling head (not
for armoured cables) Kind of U0/U = 12/20 kV

U0/U = 18/30 kV
voltage test
U0/U = 6/10 kV

P = No. of cores x conductor cross-section x 


 = permissible pulling tension N/mm2
For Cu-conductor: 50 N/mm2
For Alu-conductor: 30 N/mm2

Current carrying capacity


according to VDE 0276 part 620 or HD 620 S2 Voltage test a. c. 12 24 36
in kV
Laying in earth (ground)
Laying depth 0,7 0,8 m
Earth temperature
in the laying depth 20C Voltage test d. c. 34 67 76
Specific heat resistance 1,0 K m/W in kV up to 48 up to 96 up to 108
Load factor 0,7 (EVU-Load)

Laying in air
Air temperature 30C
Load factor (permanent load) 1,0

584
Energy- and Power Cable / Medium Voltage Power Cables

N2XSY 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, screened, PVC-sheath

Technical data Cable structure Properties


XLPE-insulated power cables to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0276 part 620, HD 620 S2 DIN VDE 0295 cl.2, multi-wire, cadmium-free and contain no silicone
and IEC 60502 BS 6360 cl.2, IEC 60228 cl.2 and free from substances harmful to
Temperature range Inner semi-conducting coating the wetting properties of lacquers
during installation up to -5C Core insulation of cross-linked polyethylene Tests
Operating temperature (XLPE), compound type DIX8 to HD 620 S2 self-extinguishing and flame retardant
max. +90C Outer conductive layer extruded and acc. to DIN VDE 0482-332-1-2,
Short circuit temperature welded with core insulation DIN EN 60332-1-2, IEC 60332-1 (equivalent
+250C (short circuit duration max. 5 s) Conductive taping DIN VDE 0472 part 804 test method B)
Nominal voltages Screen: Braiding of copper wires with one Installation notes
U0/U 6/10 kV, 12/20 kV, 18/30 kV or two tape(s) applied helically To guarantee an optimum on operating
Operating voltages Wrapping reliability the extruded semi-conductive
for 6/10 kV = max. 12 kV Outer sheath of PVC layer is spliced with the insulation for long
for 12/20 kV = max. 24 kV compound type DMV6 to HD 620 S2 duration. For this reason we recommend
for 18/30 kV = max. 36 kV Sheath colour red a peeling tool for installation.
Test voltages
for 6/10 kV = 15 kV Note
for 12/20 kV = 30 kV rm = round conductor, multi-wire
for 18/30 kV = 45 kV Further dimensions available on request.
Minimum bending radius AWG sizes are approximate equivalent
15x cable values. The actual cross-section is in mm.
Power ratings table
see Technical Informations

Application
Suitable for installation mostly for power supply stations, in indoors and in cable ducts,outdoor with protected laying, underground and in water as
well as for installation on cable trays for industries, switch-boards and power stations. Due to the good laying characteristic, this can also be laid easily
in difficult line guideways. The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer
on the XLPE insulation assures a construction free of partial discharges with high operational reliability.

Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32400 1 x 35 rm / 16 12 6 / 10 3,4 2,5 23,0 - 28,0 518,0 905,0 2
32401 1 x 50 rm / 16 12 6 / 10 3,4 2,5 24,0 - 29,0 662,0 1080,0 1
32402 1 x 70 rm / 16 12 6 / 10 3,4 2,5 26,0 - 31,0 854,0 1310,0 2/0
32403 1 x 95 rm / 16 12 6 / 10 3,4 2,5 26,0 - 32,0 1094,0 1580,0 3/0
32404 1 x 120 rm / 16 12 6 / 10 3,4 2,5 28,0 - 34,0 1334,0 1860,0 4/0
32405
32406
32407
1 x 150
1 x 150
1 x 185
rm / 16
rm / 25
rm / 16
12
12
12
6 / 10
6 / 10
6 / 10
3,4
3,4
3,4
2,5
2,5
2,5
29,0 - 35,0
29,0 - 35,0
31,0 - 37,0
1622,0
1723,0
1958,0
2040,0
2210,0
2450,0
300 kcmil
300 kcmil
350 kcmil
Q
32408 1 x 185 rm / 25 12 6 / 10 3,4 2,5 31,0 - 37,0 2059,0 2580,0 350 kcmil
32409 1 x 240 rm / 16 12 6 / 10 3,4 2,5 33,0 - 39,0 2486,0 3000,0 500 kcmil
32410 1 x 240 rm / 25 12 6 / 10 3,4 2,5 33,0 - 39,0 2587,0 3130,0 500 kcmil
32411 1 x 300 rm / 25 12 6 / 10 3,4 2,5 36,0 - 41,0 3163,0 3780,0 600 kcmil
32412 1 x 400 rm / 35 12 6 / 10 3,4 2,5 40,0 - 45,0 4234,0 4670,0 750 kcmil
32413 1 x 500 rm / 35 12 6 / 10 3,4 2,5 43,0 - 48,0 5194,0 5750,0 1000 kcmil
33099 1 x 630 rm / 35 12 6 / 10 3,4 2,5 44,0 - 49,0 6442,0 7180,0 1250 kcmil
32414 1 x 35 rm / 16 24 12 / 20 5,5 2,5 27,0 - 32,0 518,0 1110,0 2
32415 1 x 50 rm / 16 24 12 / 20 5,5 2,5 28,0 - 33,0 662,0 1250,0 1
32416 1 x 70 rm / 16 24 12 / 20 5,5 2,5 30,0 - 35,0 854,0 1510,0 2/0
32417 1 x 95 rm / 16 24 12 / 20 5,5 2,5 31,0 - 36,0 1094,0 1780,0 3/0
32418 1 x 120 rm / 16 24 12 / 20 5,5 2,5 32,0 - 38,0 1334,0 2070,0 4/0
32419 1 x 150 rm / 16 24 12 / 20 5,5 2,5 33,0 - 39,0 1622,0 2310,0 300 kcmil
32420 1 x 150 rm / 25 24 12 / 20 5,5 2,5 33,0 - 39,0 1723,0 2420,0 300 kcmil
32421 1 x 185 rm / 16 24 12 / 20 5,5 2,5 35,0 - 41,0 1958,0 2650,0 350 kcmil
32422 1 x 185 rm / 25 24 12 / 20 5,5 2,5 35,0 - 41,0 2059,0 2810,0 350 kcmil
32423 1 x 240 rm / 16 24 12 / 20 5,5 2,5 38,0 - 44,0 2486,0 3260,0 500 kcmil
32424 1 x 240 rm / 25 24 12 / 20 5,5 2,5 38,0 - 44,0 2587,0 3360,0 500 kcmil
32425 1 x 300 rm / 25 24 12 / 20 5,5 2,5 40,0 - 46,0 3163,0 4020,0 600 kcmil
32426 1 x 400 rm / 35 24 12 / 20 5,5 2,5 43,0 - 49,0 4234,0 4930,0 750 kcmil
32427 1 x 500 rm / 35 24 12 / 20 5,5 2,5 46,0 - 52,0 5194,0 6050,0 1000 kcmil
33096 1 x 630 rm / 35 24 12 / 20 5,5 2,5 47,0 - 53,0 6442,0 7510,0 1250 kcmil

Continuation

585
Energy- and Power Cable / Medium Voltage Power Cables

N2XSY 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, screened, PVC-sheath
Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32428 1 x 50 rm / 16 36 18 / 30 8 2,5 32,0 - 38,0 662,0 1480,0 1
32429 1 x 70 rm / 16 36 18 / 30 8 2,5 34,0 - 40,0 854,0 1730,0 2/0
32430 1 x 95 rm / 16 36 18 / 30 8 2,5 35,0 - 41,0 1094,0 2060,0 3/0
32431 1 x 120 rm / 16 36 18 / 30 8 2,5 37,0 - 43,0 1334,0 2330,0 4/0
32432 1 x 150 rm / 25 36 18 / 30 8 2,5 38,0 - 44,0 1723,0 2720,0 300 kcmil
32433 1 x 185 rm / 25 36 18 / 30 8 2,5 40,0 - 46,0 2059,0 3100,0 350 kcmil
32434 1 x 240 rm / 25 36 18 / 30 8 2,5 42,0 - 48,0 2587,0 3730,0 500 kcmil
32435 1 x 300 rm / 25 36 18 / 30 8 2,5 45,0 - 51,0 3163,0 4000,0 600 kcmil
32436 1 x 400 rm / 35 36 18 / 30 8 2,5 48,0 - 54,0 4234,0 5330,0 750 kcmil
32437 1 x 500 rm / 35 36 18 / 30 8 2,5 51,0 - 57,0 5194,0 6480,0 1000 kcmil
33098 1 x 630 rm / 35 36 18 / 30 8 2,5 52,0 - 59,0 6442,0 7970,0 1250 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Suitable medium voltage connection sleeves can


be found in our Cable Accessories catalogue.

586
Energy- and Power Cable / Medium Voltage Power Cables

N2XS2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, screened, PE-sheath

Technical data Cable structure Properties


XLPE-insulated power cables to IEC 60502, Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0276 part 620, HD 620 S2 DIN VDE 0295 cl.2, multi-wire, cadmium-free and contain no silicone
Temperature range BS 6360 cl.2, IEC 60228 cl.2 and free from substances harmful to
during installation up to -20C Inner semi-conducting coating the wetting properties of lacquers
Operating temperature Core insulation of cross-linked polyethylene Installation notes
max. +90C (XLPE), compound type DIX8 to HD 620 S2 To guarantee an optimum on operating
Short circuit temperature Outer extrusion of semi-conducting reliability the extruded semi-conductive
+250C (short circuit duration max. 5 s) coating spliced with the insulation layer is spliced with the insulation for long
Nominal voltages Wrapping of conductive material duration. For this reason we recommend
U0/U 6/10 kV, 12/20 kV, 18/30 kV Screen: Braiding of copper wires with one a peeling tool for installation.
Operating voltages or two tapes applied helically
for 6/10 kV = max. 12 kV Wrapping Note
for 12/20 kV = max. 24 kV Outer sheath of PE rm = round conductor, multi-wire
for 18/30 kV = max. 36 kV compound type DMP2 to HD 620 S2 Further dimensions available on request.
Test voltages Sheath colour black AWG sizes are approximate equivalent
for 6/10 kV = 15 kV values. The actual cross-section is in mm.
for 12/20 kV = 30 kV
for 18/30 kV = 45 kV
Minimum bending radius
15x cable
Power ratings
see Technical Informations

Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer sheath is resistant to high mechanical stress for laying the cables. This PE-sheath is not flame retardant
acc. to DIN EN 60332-1-2.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.

Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32480 1 x 35 rm / 16 12 6 / 10 3,4 2,5 23,0 - 28,0 518,0 910,0 2
32481 1 x 50 rm / 16 12 6 / 10 3,4 2,5 24,0 - 29,0 662,0 990,0 1
32482 1 x 70 rm / 16 12 6 / 10 3,4 2,5 26,0 - 31,0 854,0 1205,0 2/0
32483 1 x 95 rm / 16 12 6 / 10 3,4 2,5 26,0 - 32,0 1098,0 1520,0 3/0
32484 1 x 120 rm / 16 12 6 / 10 3,4 2,5 28,0 - 34,0 1334,0 1760,0 4/0
32485
32486
32487
1 x 150
1 x 150
1 x 185
rm / 16
rm / 25
rm / 16
12
12
12
6 / 10
6 / 10
6 / 10
3,4
3,4
3,4
2,5
2,5
2,5
29,0 - 35,0
29,0 - 35,0
31,0 - 37,0
1622,0
1725,0
1958,0
2020,0
2130,0
2360,0
300 kcmil
300 kcmil
350 kcmil
Q
32488 1 x 185 rm / 25 12 6 / 10 3,4 2,5 31,0 - 37,0 2059,0 2470,0 350 kcmil
32489 1 x 240 rm / 16 12 6 / 10 3,4 2,5 33,0 - 39,0 2486,0 2960,0 500 kcmil
32490 1 x 240 rm / 25 12 6 / 10 3,4 2,5 33,0 - 39,0 2587,0 3020,0 500 kcmil
32491 1 x 300 rm / 25 12 6 / 10 3,4 2,5 36,0 - 41,0 3163,0 3630,0 600 kcmil
32492 1 x 400 rm / 35 12 6 / 10 3,4 2,5 40,0 - 45,0 4234,0 4560,0 750 kcmil
32493 1 x 500 rm / 35 12 6 / 10 3,4 2,5 43,0 - 48,0 5194,0 5580,0 1000 kcmil
32494 1 x 35 rm / 16 24 12 / 20 5,5 2,5 27,0 - 32,0 518,0 960,0 2
32495 1 x 50 rm / 16 24 12 / 20 5,5 2,5 28,0 - 33,0 662,0 1160,0 1
32496 1 x 70 rm / 16 24 12 / 20 5,5 2,5 30,0 - 35,0 854,0 1410,0 2/0
32497 1 x 95 rm / 16 24 12 / 20 5,5 2,5 31,0 - 36,0 1094,0 1670,0 3/0
32498 1 x 120 rm / 16 24 12 / 20 5,5 2,5 33,0 - 38,0 1334,0 1960,0 4/0
32499 1 x 150 rm / 16 24 12 / 20 5,5 2,5 34,0 - 39,0 1622,0 2220,0 300 kcmil
32500 1 x 150 rm / 25 24 12 / 20 5,5 2,5 34,0 - 39,0 1723,0 2310,0 300 kcmil
32501 1 x 185 rm / 16 24 12 / 20 5,5 2,5 36,0 - 41,0 1958,0 2620,0 350 kcmil
32502 1 x 185 rm / 25 24 12 / 20 5,5 2,5 36,0 - 41,0 2059,0 2670,0 350 kcmil
32503 1 x 240 rm / 16 24 12 / 20 5,5 2,5 39,0 - 44,0 2486,0 3160,0 500 kcmil
32504 1 x 240 rm / 25 24 12 / 20 5,5 2,5 39,0 - 44,0 2587,0 3270,0 500 kcmil
32505 1 x 300 rm / 25 24 12 / 20 5,5 2,5 41,0 - 46,0 3163,0 3880,0 600 kcmil
32506 1 x 400 rm / 35 24 12 / 20 5,5 2,5 44,0 - 49,0 4234,0 4820,0 750 kcmil
32507 1 x 500 rm / 35 24 12 / 20 5,5 2,5 47,0 - 52,0 5194,0 5860,0 1000 kcmil
32508 1 x 50 rm / 16 36 18 / 30 8 2,5 32,0 - 38,0 662,0 1410,0 1
32509 1 x 70 rm / 16 36 18 / 30 8 2,5 34,0 - 40,0 854,0 1660,0 2/0

Continuation

587
Energy- and Power Cable / Medium Voltage Power Cables

N2XS2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, screened, PE-sheath
Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32510 1 x 95 rm / 16 36 18 / 30 8 2,5 35,0 - 41,0 1094,0 1970,0 3/0
32511 1 x 120 rm / 16 36 18 / 30 8 2,5 37,0 - 43,0 1334,0 2220,0 4/0
32512 1 x 150 rm / 25 36 18 / 30 8 2,5 38,0 - 44,0 1723,0 2650,0 300 kcmil
32513 1 x 185 rm / 25 36 18 / 30 8 2,5 40,0 - 46,0 2059,0 2980,0 350 kcmil
32514 1 x 240 rm / 25 36 18 / 30 8 2,5 42,0 - 48,0 2587,0 3570,0 500 kcmil
32515 1 x 300 rm / 25 36 18 / 30 8 2,5 45,0 - 51,0 3163,0 4220,0 600 kcmil
32516 1 x 400 rm / 35 36 18 / 30 8 2,5 48,0 - 54,0 4234,0 5170,0 750 kcmil
32517 1 x 500 rm / 35 36 18 / 30 8 2,5 51,0 - 57,0 5194,0 6260,0 1000 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Suitable medium voltage connection sleeves can


be found in our Cable Accessories catalogue.

588
Energy- and Power Cable / Medium Voltage Power Cables

N2XS(F)2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, longitudinally water-tight, screened, PE-sheath

Technical data Cable structure Properties


XLPE-insulated power cables to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0276 part 620, HD 620 S2 and DIN VDE 0295 cl.2, multi-wire, cadmium-free and contain no silicone
IEC 60502 BS 6360 cl.2, IEC 60228 cl.2 and free from substances harmful to
Temperature range Inner semi-conducting coating the wetting properties of lacquers
during installation up to -20C Core insulation of cross-linked polyethylene Installation notes
Operating temperature (XLPE), compound type DIX8 to HD 620 S2 To guarantee an optimum on operating
max. +90C Outer extrusion of semi-conducting reliability the extruded semi-conductive
Short circuit temperature coating spliced with the XLPE-insulation layer is spliced with the insulation for long
+250C (short circuit duration max. 5 s) Longitudinally water-tight, conductive duration. For this reason we recommend
Nominal voltages wrapping a peeling tool for installation
U0/U 6/10 kV, 12/20 kV, 18/30 kV Screen: Braiding of copper wires with one
Operating voltages or two tapes applied helically Note
for 6/10 kV = max. 12 kV Longitudinally water-tight wrapping rm = round conductor, multi-wire
for 12/20 kV = max. 24 kV Outer sheath of PE Further types and dimensions on request.
for 18/30 kV = max. 36 kV compound type DMP2 to HD 620 S2 AWG sizes are approximate equivalent
Test voltages Sheath colour black values. The actual cross-section is in mm.
for 6/10 kV = 15 kV
for 12/20 kV = 30 kV
for 18/30 kV = 45 kV
Minimum bending radius
15x cable
Power ratings
see Technical Informations

Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer sheath is resistant to high mechanical stress for laying the cables. This PE sheath is not flame retardant
acc. to DIN EN 60332-1-2.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.

Part no. No.cores x Operation Nominal Insulation Screen Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. thickness app. mm weight app. kg / km
mm max. kV mm mm Nominal kg / km
value
mm
32560 1 x 35 rm / 16 12 6 / 10 3,4 16 2,5 26,0 518,0 1050,0 2
32561 1 x 50 rm / 16 12 6 / 10 3,4 16 2,5 28,0 662,0 1150,0 1
32562 1 x 70 rm / 16 12 6 / 10 3,4 16 2,5 30,0 854,0 1460,0 2/0
32563 1 x 95 rm / 16 12 6 / 10 3,4 16 2,5 31,0 1094,0 1700,0 3/0
32564
32565
1 x 120
1 x 150
rm / 16
rm / 25
12
12
6 / 10
6 / 10
3,4
3,4
16
25
2,5
2,5
32,0
34,0
1334,0
1723,0
2030,0
2350,0
4/0
300 kcmil
Q
32566 1 x 185 rm / 25 12 6 / 10 3,4 25 2,5 36,0 2059,0 2700,0 350 kcmil
32567 1 x 240 rm / 25 12 6 / 10 3,4 25 2,5 38,0 2587,0 3300,0 500 kcmil
32568 1 x 300 rm / 25 12 6 / 10 3,4 25 2,5 40,0 3163,0 3900,0 600 kcmil
32569 1 x 400 rm / 35 12 6 / 10 3,4 35 2,5 44,0 4234,0 4850,0 750 kcmil
32570 1 x 500 rm / 35 12 6 / 10 3,4 35 2,5 47,0 5194,0 6000,0 1000 kcmil
79954 1 x 630 rm / 35 12 6 / 10 3,4 35 2,5 49,0 6442,0 7020,0 1250 kcmil
32571 1 x 35 rm / 16 24 12 / 20 5,5 16 2,5 31,0 518,0 1210,0 2
32572 1 x 50 rm / 16 24 12 / 20 5,5 16 2,5 33,0 662,0 1400,0 1
32573 1 x 70 rm / 16 24 12 / 20 5,5 16 2,5 34,0 854,0 1550,0 2/0
32574 1 x 95 rm / 16 24 12 / 20 5,5 16 2,5 36,0 1094,0 1800,0 3/0
32575 1 x 120 rm / 16 24 12 / 20 5,5 16 2,5 37,0 1334,0 2150,0 4/0
32576 1 x 150 rm / 25 24 12 / 20 5,5 25 2,5 39,0 1723,0 2400,0 300 kcmil
32577 1 x 185 rm / 25 24 12 / 20 5,5 25 2,5 41,0 2059,0 2850,0 350 kcmil
32578 1 x 240 rm / 25 24 12 / 20 5,5 25 2,5 43,0 2587,0 3250,0 500 kcmil
32579 1 x 300 rm / 25 24 12 / 20 5,5 25 2,5 45,0 3163,0 3850,0 600 kcmil
32580 1 x 400 rm / 35 24 12 / 20 5,5 35 2,5 48,0 4234,0 4900,0 750 kcmil
32581 1 x 500 rm / 35 24 12 / 20 5,5 35 2,5 52,0 5194,0 6100,0 1000 kcmil
33092 1 x 630 rm / 35 24 12 / 20 5,5 35 2,5 54,0 6442,0 7340,0 1250 kcmil

Continuation

589
Energy- and Power Cable / Medium Voltage Power Cables

N2XS(F)2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, longitudinally water-tight, screened, PE-sheath
Part no. No.cores x Operation Nominal Insulation Screen Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. thickness app. mm weight app. kg / km
mm max. kV mm mm Nominal kg / km
value
mm
32582 1 x 50 rm / 16 36 18 / 30 8 16 2,5 37,0 662,0 1700,0 1
32583 1 x 70 rm / 16 36 18 / 30 8 16 2,5 38,0 854,0 1950,0 2/0
32584 1 x 95 rm / 16 36 18 / 30 8 16 2,5 40,0 1094,0 2300,0 3/0
32585 1 x 120 rm / 16 36 18 / 30 8 16 2,5 42,0 1334,0 2600,0 4/0
32586 1 x 150 rm / 25 36 18 / 30 8 25 2,5 43,0 1723,0 3000,0 300 kcmil
32587 1 x 185 rm / 25 36 18 / 30 8 25 2,5 45,0 2059,0 3350,0 350 kcmil
32588 1 x 240 rm / 25 36 18 / 30 8 25 2,5 47,0 2587,0 4100,0 500 kcmil
32589 1 x 300 rm / 25 36 18 / 30 8 25 2,5 50,0 3163,0 4800,0 600 kcmil
32590 1 x 400 rm / 35 36 18 / 30 8 35 2,5 53,0 4234,0 5750,0 750 kcmil
32591 1 x 500 rm / 35 36 18 / 30 8 35 2,5 56,0 5194,0 6700,0 1000 kcmil
708487 1 x 630 rm / 35 36 18 / 30 8 35 2,5 59,0 6442,0 7760,0 1250 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

590
Energy- and Power Cable / Medium Voltage Power Cables

N2XS(FL)2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, longitudinally and crosswise water-tight, screened, PE-sheath

Technical data Cable structure Properties


XLPE-insulated power cables to Bare copper-conductor, to The materials used in manufacture are
DIN VDE 0276 part 620, HD 620 S2 DIN VDE 0295 cl.2, multi-wire, cadmium-free and contain no silicone
and IEC 60502 BS 6360 cl.2, IEC 60228 cl.2 and free from substances harmful to
Temperature range Inner semi-conducting coating the wetting properties of lacquers
during installation up to -20C Core insulation of cross-linked polyethylene Installation notes
Operating temperature (XLPE), compound type DIX8 to HD 620 S2 To guarantee an optimum on operating
max. +90C Outer extrusion of semi-conducting reliability the extruded semi-conductive
Short circuit temperature coating spliced with the XLPE-insulation layer is spliced with the insulation for long
+250C (short circuit duration max. 5 s) Longitudinally water-tight, conductive duration. For this reason we recommend
Nominal voltages wrapping a peeling tool for installation
U0/U 6/10 kV, 12/20 kV, 18/30 kV Screen: Braiding of copper wires with
Operating voltages one or two tapes applied helically Note
for 6/10 kV = max. 12 kV Longitudinally water-tight wrapping rm = round conductor, multi-wire
for 12/20 kV = max. 24 kV Aluminium tape spliced with Further types and dimensions on request.
for 18/30 kV = max. 36 kV PE sheath AWG sizes are approximate equivalent
Test voltages Outer sheath of PE values. The actual cross-section is in mm.
for 6/10 kV = 15 kV compound type DMP2 to HD 620 S2
for 12/20 kV = 30 kV Sheath colour black
for 18/30 kV = 45 kV
Minimum bending radius
15x cable
Power ratings
see Technical Informations

Application
Installation primarily for power utility grids and in cable ducts, outdoors, underground and in water, and also on pallets for manufacturing plants,
switchgear and power stations. The resistant Al/PE-laminated sheathing acts as a cross water barrier. It inhibits the diffusion of water. In case of
sheathing damage, water impact is contained at the flaw. The cable can be severely mechanically stressed during installation and operation. The PE
sheathing is not flame-retardant to DIN EN 60332-1-2. The internal conductive layer between conductor and VPE insulation and the adherent external
conductive layer on the VPE insulation guarantees a design with high operational safety and no partial discharge.

Part no. No.cores x Operation Nominal Insulation Screen Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. thickness app. mm weight app. kg / km
mm max. kV mm mm Nominal kg / km
value
mm
33054 1 x 35 rm / 16 12 6 / 10 3,4 16 2,5 28,0 518,0 860,0 2
33055 1 x 50 rm / 16 12 6 / 10 3,4 16 2,5 30,0 662,0 1000,0 1
33056 1 x 70 rm / 16 12 6 / 10 3,4 16 2,5 32,0 854,0 1350,0 2/0
33057 1 x 95 rm / 16 12 6 / 10 3,4 16 2,5 33,0 1094,0 1680,0 3/0
33058
33059
1 x 120
1 x 150
rm / 16
rm / 25
12
12
6 / 10
6 / 10
3,4
3,4
16
25
2,5
2,5
34,0
36,0
1334,0
1723,0
2070,0
2350,0
4/0
300 kcmil
Q
33060 1 x 185 rm / 25 12 6 / 10 3,4 25 2,5 38,0 2059,0 2710,0 350 kcmil
33061 1 x 240 rm / 25 12 6 / 10 3,4 25 2,5 40,0 2587,0 3260,0 500 kcmil
38049 1 x 300 rm / 25 12 6 / 10 3,4 25 2,5 42,0 3163,0 3850,0 600 kcmil
38050 1 x 400 rm / 35 12 6 / 10 3,4 35 2,5 46,0 4234,0 4740,0 750 kcmil
38051 1 x 500 rm / 35 12 6 / 10 3,4 35 2,5 49,0 5194,0 5800,0 1000 kcmil
38052 1 x 630 rm / 35 12 6 / 10 3,4 35 2,5 51,0 6442,0 7120,0 1250 kcmil
38053 1 x 35 rm / 16 24 12 / 20 5,5 16 2,5 33,0 518,0 1020,0 2
33066 1 x 50 rm / 16 24 12 / 20 5,5 16 2,5 35,0 662,0 1170,0 1
33067 1 x 70 rm / 16 24 12 / 20 5,5 16 2,5 36,0 854,0 1470,0 2/0
33083 1 x 95 rm / 16 24 12 / 20 5,5 16 2,5 38,0 1094,0 1860,0 3/0
33069 1 x 120 rm / 16 24 12 / 20 5,5 16 2,5 39,0 1334,0 2260,0 4/0
33070 1 x 150 rm / 25 24 12 / 20 5,5 25 2,5 41,0 1723,0 2550,0 300 kcmil
33071 1 x 185 rm / 25 24 12 / 20 5,5 25 2,5 43,0 2059,0 2920,0 350 kcmil
33072 1 x 240 rm / 25 24 12 / 20 5,5 25 2,5 45,0 2587,0 3490,0 500 kcmil
33073 1 x 300 rm / 25 24 12 / 20 5,5 25 2,5 47,0 3163,0 4090,0 600 kcmil
33074 1 x 400 rm / 35 24 12 / 20 5,5 35 2,5 50,0 4234,0 5010,0 750 kcmil
33075 1 x 500 rm / 35 24 12 / 20 5,5 35 2,5 54,0 5194,0 6090,0 1000 kcmil
38054 1 x 630 rm / 35 24 12 / 20 5,5 35 2,5 55,0 6442,0 7440,0 1250 kcmil

Continuation

591
Energy- and Power Cable / Medium Voltage Power Cables

N2XS(FL)2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Cu-conductor, single core, longitudinally and crosswise water-tight, screened, PE-sheath
Part no. No.cores x Operation Nominal Insulation Screen Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. thickness app. mm weight app. kg / km
mm max. kV mm mm Nominal kg / km
value
mm
34312 1 x 50 rm / 16 36 18 / 30 8 16 2,5 36,0 662,0 1400,0 1
38055 1 x 70 rm / 16 36 18 / 30 8 16 2,5 40,0 854,0 1710,0 2/0
38056 1 x 95 rm / 16 36 18 / 30 8 16 2,5 42,0 1094,0 2110,0 3/0
38057 1 x 120 rm / 16 36 18 / 30 8 16 2,5 44,0 1334,0 2520,0 4/0
38058 1 x 150 rm / 25 36 18 / 30 8 25 2,5 45,0 1723,0 2830,0 300 kcmil
34313 1 x 185 rm / 25 36 18 / 30 8 25 2,5 47,0 2059,0 3210,0 350 kcmil
38059 1 x 240 rm / 25 36 18 / 30 8 25 2,5 49,0 2587,0 3790,0 500 kcmil
34314 1 x 300 rm / 25 36 18 / 30 8 25 2,5 52,0 3163,0 4430,0 600 kcmil
34315 1 x 400 rm / 35 36 18 / 30 8 35 2,5 55,0 4234,0 5390,0 750 kcmil
38060 1 x 500 rm / 35 36 18 / 30 8 35 2,5 58,0 5194,0 6500,0 1000 kcmil
38061 1 x 630 rm / 35 36 18 / 30 8 35 2,5 60,0 6442,0 7870,0 1250 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

592
Energy- and Power Cable / Medium Voltage Power Cables

NA2XSY 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


alu-conductor, single core, screened, PVC-sheath

Technical data Cable structure Properties


XLPE-insulated power cables to Aluminium-conductor, to The materials used in manufacture are
DIN VDE 0276 part 620, HD 620 S2 and DIN VDE 0295 cl.2, multi-wire, cadmium-free and contain no silicone
IEC 60502 BS 6360 cl.2, IEC 60228 cl.2 and free from substances harmful to
Temperature range Inner semi-conducting coating the wetting properties of lacquers
during installation up to -5C Core insulation of cross-linked polyethylene Tests
Operating temperature (XLPE), compound type DIX8 to HD 620 S2 self-extinguishing and flame retardant
max. +90C Outer extrusion of semi-conducting acc. to DIN VDE 0482-332-1-2,
Short circuit temperature coating spliced with the insulation DIN EN 60332-1-2, IEC 60332-1 (equivalent
+250C (short circuit duration max. 5 s) Wrapping of conductive material DIN VDE 0472 part 804 test method B)
Nominal voltages Screen: Braiding of copper wires with one Installation notes
U0/U 6/10 kV, 12/20 kV, 18/30 kV or two tapes applied helically To guarantee an optimum on operating
Operating voltages Wrapping reliability the extruded semi-conductive
for 6/10 kV = max. 12 kV Outer sheath of PVC layer is spliced with the insulation for long
for 12/20 kV = max. 24 kV compound type DMV6 to HD 620 S2 duration. For this reason we recommend
for 18/30 kV = max. 36 kV Sheath colour red a peeling tool for installation
Test voltages
for 6/10 kV = 15 kV Note
for 12/20 kV = 30 kV rm = round conductor, multi-wire
for 18/30 kV = 45 kV Further dimensions available on request.
Minimum bending radius AWG sizes are approximate equivalent
15x cable values. The actual cross-section is in mm.
Power ratings
see Technical Informations

Application
Suitable for installation mostly for power supply stations, in indoors and in cable ducts, outdoor with protected laying, underground and in water as
well as for installation on cable trays for industries, switch-boards and power stations. Due to the good laying characteristic, this can also be laid easily
in difficult line guideways.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.

Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight kg / km app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32440 1 x 50 rm / 16 12 6 / 10 3,4 2,5 24,0 - 29,0 182,0 145,0 780,0 1
32441 1 x 70 rm / 16 12 6 / 10 3,4 2,5 26,0 - 31,0 182,0 203,0 875,0 2/0
32442 1 x 95 rm / 16 12 6 / 10 3,4 2,5 26,0 - 32,0 182,0 276,0 990,0 3/0
32443 1 x 120 rm / 16 12 6 / 10 3,4 2,5 28,0 - 34,0 182,0 348,0 1110,0 4/0
32444
32445
1 x 150
1 x 150
rm / 16
rm / 25
12
12
6 / 10
6 / 10
3,4
3,4
2,5
2,5
29,0 - 35,0
29,0 - 35,0
182,0
283,0
435,0
435,0
1240,0
1310,0
300 kcmil
300 kcmil
Q
32446 1 x 185 rm / 16 12 6 / 10 3,4 2,5 31,0 - 37,0 182,0 537,0 1405,0 350 kcmil
32447 1 x 185 rm / 25 12 6 / 10 3,4 2,5 31,0 - 37,0 283,0 537,0 1460,0 350 kcmil
32448 1 x 240 rm / 16 12 6 / 10 3,4 2,5 33,0 - 39,0 182,0 696,0 1615,0 500 kcmil
32449 1 x 240 rm / 25 12 6 / 10 3,4 2,5 33,0 - 39,0 283,0 696,0 1660,0 500 kcmil
32450 1 x 300 rm / 25 12 6 / 10 3,4 2,5 36,0 - 41,0 283,0 870,0 1910,0 600 kcmil
32451 1 x 400 rm / 35 12 6 / 10 3,4 2,5 40,0 - 45,0 394,0 1160,0 2315,0 750 kcmil
32452 1 x 500 rm / 35 12 6 / 10 3,4 2,5 43,0 - 48,0 394,0 1450,0 2750,0 1000 kcmil
32453 1 x 50 rm / 16 24 12 / 20 5,5 2,5 28,0 - 33,0 182,0 145,0 950,0 1
32454 1 x 70 rm / 16 24 12 / 20 5,5 2,5 30,0 - 35,0 182,0 203,0 1110,0 2/0
32455 1 x 95 rm / 16 24 12 / 20 5,5 2,5 31,0 - 36,0 182,0 276,0 1220,0 3/0
32456 1 x 120 rm / 16 24 12 / 20 5,5 2,5 32,0 - 38,0 182,0 348,0 1310,0 4/0
32457 1 x 150 rm / 16 24 12 / 20 5,5 2,5 33,0 - 39,0 182,0 435,0 1460,0 300 kcmil
32458 1 x 150 rm / 25 24 12 / 20 5,5 2,5 33,0 - 39,0 283,0 435,0 1520,0 300 kcmil
32459 1 x 185 rm / 16 24 12 / 20 5,5 2,5 35,0 - 41,0 182,0 537,0 1660,0 350 kcmil
32460 1 x 185 rm / 25 24 12 / 20 5,5 2,5 35,0 - 41,0 283,0 537,0 1720,0 350 kcmil
32461 1 x 240 rm / 16 24 12 / 20 5,5 2,5 38,0 - 44,0 182,0 696,0 1860,0 500 kcmil
32462 1 x 240 rm / 25 24 12 / 20 5,5 2,5 38,0 - 44,0 283,0 696,0 1910,0 500 kcmil
32463 1 x 300 rm / 25 24 12 / 20 5,5 2,5 40,0 - 46,0 283,0 870,0 2220,0 600 kcmil
32464 1 x 400 rm / 35 24 12 / 20 5,5 2,5 43,0 - 49,0 394,0 1160,0 2620,0 750 kcmil
32465 1 x 500 rm / 35 24 12 / 20 5,5 2,5 46,0 - 52,0 394,0 1450,0 3030,0 1000 kcmil
32466 1 x 50 rm / 16 36 18 / 30 8 2,5 32,0 - 38,0 182,0 145,0 1260,0 1
32467 1 x 70 rm / 16 36 18 / 30 8 2,5 34,0 - 40,0 182,0 203,0 1360,0 2/0

Continuation

593
Energy- and Power Cable / Medium Voltage Power Cables

NA2XSY 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


alu-conductor, single core, screened, PVC-sheath
Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight kg / km app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32468 1 x 95 rm / 16 36 18 / 30 8 2,5 35,0 - 41,0 182,0 276,0 1510,0 3/0
32469 1 x 120 rm / 16 36 18 / 30 8 2,5 37,0 - 43,0 182,0 348,0 1610,0 4/0
32470 1 x 150 rm / 16 36 18 / 30 8 2,5 38,0 - 44,0 182,0 435,0 1760,0 300 kcmil
32471 1 x 150 rm / 25 36 18 / 30 8 2,5 38,0 - 44,0 283,0 435,0 1810,0 300 kcmil
32472 1 x 185 rm / 16 36 18 / 30 8 2,5 40,0 - 46,0 182,0 537,0 1960,0 350 kcmil
32473 1 x 185 rm / 25 36 18 / 30 8 2,5 40,0 - 46,0 283,0 537,0 2020,0 350 kcmil
32474 1 x 240 rm / 16 36 18 / 30 8 2,5 42,0 - 48,0 182,0 696,0 2210,0 500 kcmil
32475 1 x 240 rm / 25 36 18 / 30 8 2,5 42,0 - 48,0 283,0 696,0 2260,0 500 kcmil
32476 1 x 300 rm / 25 36 18 / 30 8 2,5 45,0 - 51,0 283,0 870,0 2560,0 600 kcmil
32477 1 x 400 rm / 35 36 18 / 30 8 2,5 48,0 - 54,0 394,0 1160,0 2960,0 750 kcmil
32478 1 x 500 rm / 35 36 18 / 30 8 2,5 51,0 - 57,0 394,0 1450,0 3460,0 1000 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Suitable medium voltage connection sleeves can


be found in our Cable Accessories catalogue.

594
Energy- and Power Cable / Medium Voltage Power Cables

NA2XS2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Alu-conductor, single core, screened, PE-sheath

Technical data Cable structure Properties


XLPE-insulated power cables to Aluminium-conductor, to The materials used in manufacture are
DIN VDE 0276 part 620, HD 620 S2 and DIN VDE 0295 cl.2, multi-wire, cadmium-free and contain no silicone
IEC 60502 BS 6360 cl.2, IEC 60228 cl.2 and free from substances harmful to
Temperature range Inner semi-conducting coating the wetting properties of lacquers
during installation up to -20C Core insulation of cross-linked polyethylene Installation notes
Operating temperature (XLPE), compound type DIX8 to HD 620 S2 To guarantee an optimum on operating
max. +90C Outer extrusion of semi-conducting coating reliability the extruded semi-conductive
Short circuit temperature spliced with the insulation layer is spliced with the insulation for long
+250C (short circuit duration max. 5 s) Wrapping of conductive material duration. For this reason we recommend
Nominal voltages Screen: Braiding of copper wires with one a peeling tool for installation.
U0/U 6/10 kV, 12/20 kV, 18/30 kV or two tapes applied helically
Operating voltages Wrapping Note
for 6/10 kV = max. 12 kV Outer sheath of PE rm = round conductor, multi-wire
for 12/20 kV = max. 24 kV compound type DMP2 to HD 620 S2 Further dimensions available on request.
for 18/30 kV = max. 36 kV Sheath colour black AWG sizes are approximate equivalent
Test voltages values. The actual cross-section is in mm.
for 6/10 kV = 15 kV
for 12/20 kV = 30 kV
for 18/30 kV = 45 kV
Minimum bending radius
15x cable
Power ratings
see Technical Informations

Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer sheath is resistant to high mechanical stress for laying the cables. This PE sheath is not flame retardant
acc. to DIN EN 60332-1-2.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.

Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight kg / km app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32520 1 x 50 rm / 16 12 6 / 10 3,4 2,5 24,0 - 29,0 182,0 145,0 710,0 1
32521 1 x 70 rm / 16 12 6 / 10 3,4 2,5 26,0 - 31,0 182,0 203,0 790,0 2/0
32522 1 x 95 rm / 16 12 6 / 10 3,4 2,5 26,0 - 32,0 182,0 276,0 920,0 3/0
32523 1 x 120 rm / 16 12 6 / 10 3,4 2,5 28,0 - 34,0 182,0 348,0 990,0 4/0
32524
32525
1 x 150
1 x 150
rm / 16
rm / 25
12
12
6 / 10
6 / 10
3,4
3,4
2,5
2,5
29,0 - 35,0
29,0 - 35,0
182,0
283,0
435,0
435,0
1110,0
1220,0
300 kcmil
300 kcmil
Q
32526 1 x 185 rm / 16 12 6 / 10 3,4 2,5 31,0 - 37,0 182,0 537,0 1260,0 350 kcmil
32527 1 x 185 rm / 25 12 6 / 10 3,4 2,5 33,0 - 39,0 283,0 537,0 1370,0 350 kcmil
32528 1 x 240 rm / 16 12 6 / 10 3,4 2,5 33,0 - 39,0 182,0 696,0 1480,0 500 kcmil
32529 1 x 240 rm / 25 12 6 / 10 3,4 2,5 33,0 - 39,0 283,0 696,0 1530,0 500 kcmil
32530 1 x 300 rm / 25 12 6 / 10 3,4 2,5 36,0 - 41,0 283,0 870,0 1820,0 600 kcmil
32531 1 x 400 rm / 35 12 6 / 10 3,4 2,5 40,0 - 45,0 394,0 1160,0 2220,0 750 kcmil
32532 1 x 500 rm / 35 12 6 / 10 3,4 2,5 43,0 - 48,0 394,0 1450,0 2570,0 1000 kcmil
32533 1 x 50 rm / 16 24 12 / 20 5,5 2,5 28,0 - 33,0 182,0 145,0 890,0 1
32534 1 x 70 rm / 16 24 12 / 20 5,5 2,5 30,0 - 35,0 182,0 203,0 970,0 2/0
32535 1 x 95 rm / 16 24 12 / 20 5,5 2,5 31,0 - 36,0 182,0 276,0 1120,0 3/0
32536 1 x 120 rm / 16 24 12 / 20 5,5 2,5 32,0 - 38,0 182,0 348,0 1210,0 4/0
32537 1 x 150 rm / 16 24 12 / 20 5,5 2,5 33,0 - 39,0 182,0 435,0 1370,0 300 kcmil
32538 1 x 150 rm / 25 24 12 / 20 5,5 2,5 33,0 - 39,0 283,0 435,0 1420,0 300 kcmil
32539 1 x 185 rm / 16 24 12 / 20 5,5 2,5 35,0 - 41,0 182,0 537,0 1530,0 350 kcmil
32540 1 x 185 rm / 25 24 12 / 20 5,5 2,5 35,0 - 41,0 283,0 537,0 1570,0 350 kcmil
32541 1 x 240 rm / 16 24 12 / 20 5,5 2,5 38,0 - 44,0 182,0 696,0 1720,0 500 kcmil
32542 1 x 240 rm / 25 24 12 / 20 5,5 2,5 38,0 - 44,0 283,0 696,0 1830,0 500 kcmil
32543 1 x 300 rm / 25 24 12 / 20 5,5 2,5 40,0 - 46,0 283,0 870,0 2070,0 600 kcmil
32544 1 x 400 rm / 35 24 12 / 20 5,5 2,5 43,0 - 49,0 394,0 1160,0 2460,0 750 kcmil
32545 1 x 500 rm / 35 24 12 / 20 5,5 2,5 46,0 - 52,0 394,0 1450,0 2890,0 1000 kcmil
33078 1 x 630 rm / 35 24 12 / 20 5,5 2,5 47,0 - 53,0 394,0 1827,0 3370,0 1250 kcmil
32546 1 x 50 rm / 16 36 18 / 30 8 2,5 32,0 - 38,0 182,0 145,0 1120,0 1

Continuation

595
Energy- and Power Cable / Medium Voltage Power Cables

NA2XS2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


Alu-conductor, single core, screened, PE-sheath
Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight kg / km app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32547 1 x 70 rm / 16 36 18 / 30 8 2,5 34,0 - 40,0 182,0 203,0 1270,0 2/0
32548 1 x 95 rm / 16 36 18 / 30 8 2,5 35,0 - 41,0 182,0 276,0 1380,0 3/0
32549 1 x 120 rm / 16 36 18 / 30 8 2,5 37,0 - 43,0 182,0 348,0 1530,0 4/0
32550 1 x 150 rm / 25 36 18 / 30 8 2,5 38,0 - 44,0 283,0 435,0 1720,0 300 kcmil
32551 1 x 185 rm / 25 36 18 / 30 8 2,5 40,0 - 46,0 283,0 537,0 1860,0 350 kcmil
32552 1 x 240 rm / 25 36 18 / 30 8 2,5 42,0 - 48,0 283,0 696,0 2110,0 500 kcmil
32553 1 x 300 rm / 25 36 18 / 30 8 2,5 45,0 - 51,0 283,0 870,0 2370,0 600 kcmil
32554 1 x 400 rm / 35 36 18 / 30 8 2,5 48,0 - 54,0 394,0 1160,0 2820,0 750 kcmil
32555 1 x 500 rm / 35 36 18 / 30 8 2,5 51,0 - 57,0 394,0 1450,0 3280,0 1000 kcmil
32999 1 x 630 rm / 35 36 18 / 30 8 2,5 52,0 - 59,0 394,0 1827,0 3770,0 1250 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Suitable medium voltage connection sleeves can


be found in our Cable Accessories catalogue.

596
Energy- and Power Cable / Medium Voltage Power Cables

NA2XS(F)2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


alu-conductor, single core, longitudinally water-tight, screened, PE-sheath

Technical data Cable structure Properties


XLPE-insulated power cables to Aluminium-conductor, to The materials used in manufacture are
DIN VDE 0276 part 620, HD 620 S2 DIN VDE 0295 cl.2, multi-wire, cadmium-free and contain no silicone
and IEC 60502 BS 6360 cl.2, IEC 60228 cl.2 and free from substances harmful to
Temperature range Inner semi-conducting coating the wetting properties of lacquers
during installation up to -20C Core insulation of cross-linked polyethylene Installation notes
Operating temperature (XLPE), compound type DIX8 to HD 620 S2 To guarantee an optimum on operating
max. +90C Outer extrusion of semi-conducting reliability the extruded semi-conductive
Short circuit temperature coating spliced with the XLPE-insulation layer is spliced with the insulation for long
+250C (short circuit duration max. 5 s) Longitudinally water-tight, conductive duration. For this reason we recommend
Nominal voltages wrapping a peeling tool for installation.
U0/U 6/10 kV, 12/20 kV, 18/30 kV Screen: Braiding of copper wires with one
Operating voltages or two tapes applied helically Note
for 6/10 kV = max. 12 kV Longitudinally water-tight wrapping rm = round conductor, multi-wire
for 12/20 kV = max. 24 kV Outer sheath of PE Further types and dimensions on request.
for 18/30 kV = max. 36 kV compound typeDMP2 to HD 620 S2 AWG sizes are approximate equivalent
Test voltages Sheath colour black values. The actual cross-section is in mm.
for 6/10 kV = 15 kV Sheath thickness voltage 2,5 mm
for 12/20 kV = 30 kV
for 18/30 kV = 45 kV
Minimum bending radius
15x cable
Power ratings
see Technical Informations

Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer sheath is resistant to high mechanical stress for laying the cables. This PE sheath is not flame retardant
acc. to DIN EN 60332-1-2.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.

Part no. No.cores x Operation Nominal Insulation Screen Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. app. mm weight kg / km app. kg / km
mm max. kV mm mm kg / km
32600 1 x 35 rm / 16 12 6 / 10 3,4 16 26,0 182,0 102,0 780,0 2
32601 1 x 50 rm / 16 12 6 / 10 3,4 16 28,0 182,0 145,0 850,0 1
32602 1 x 70 rm / 16 12 6 / 10 3,4 16 30,0 182,0 203,0 980,0 2/0
32603 1 x 95 rm / 16 12 6 / 10 3,4 16 31,0 182,0 276,0 1080,0 3/0
32604 1 x 120 rm / 16 12 6 / 10 3,4 16 32,0 182,0 348,0 1150,0 4/0

Q
32605 1 x 150 rm / 25 12 6 / 10 3,4 25 34,0 283,0 435,0 1280,0 300 kcmil
32606 1 x 185 rm / 25 12 6 / 10 3,4 25 36,0 283,0 537,0 1420,0 350 kcmil
32607 1 x 240 rm / 25 12 6 / 10 3,4 25 38,0 283,0 696,0 1630,0 500 kcmil
32608 1 x 300 rm / 25 12 6 / 10 3,4 25 40,0 283,0 870,0 1950,0 600 kcmil
32609 1 x 400 rm / 35 12 6 / 10 3,4 35 44,0 394,0 1160,0 2350,0 750 kcmil
32610 1 x 500 rm / 35 12 6 / 10 3,4 35 47,0 394,0 1450,0 2780,0 1000 kcmil
32611 1 x 50 rm / 16 24 12 / 20 5,5 16 33,0 182,0 145,0 920,0 1
32612 1 x 70 rm / 16 24 12 / 20 5,5 16 34,0 182,0 203,0 1030,0 2/0
32613 1 x 95 rm / 16 24 12 / 20 5,5 16 36,0 182,0 276,0 1140,0 3/0
32614 1 x 120 rm / 16 24 12 / 20 5,5 16 37,0 182,0 348,0 1250,0 4/0
32615 1 x 150 rm / 25 24 12 / 20 5,5 25 39,0 283,0 435,0 1320,0 300 kcmil
32616 1 x 185 rm / 25 24 12 / 20 5,5 25 41,0 283,0 537,0 1570,0 350 kcmil
32617 1 x 240 rm / 25 24 12 / 20 5,5 25 43,0 283,0 696,0 1780,0 500 kcmil
32618 1 x 300 rm / 25 24 12 / 20 5,5 25 45,0 283,0 870,0 2100,0 600 kcmil
32619 1 x 400 rm / 35 24 12 / 20 5,5 35 48,0 394,0 1160,0 2480,0 750 kcmil
32620 1 x 500 rm / 35 24 12 / 20 5,5 35 50,0 394,0 1450,0 2900,0 1000 kcmil
33090 1 x 630 rm / 35 24 12 / 20 5,5 35 52,0 394,0 1827,0 3380,0 1250 kcmil
33091 1 x 800 rm / 35 24 12 / 20 5,5 35 57,0 394,0 2320,0 4400,0 1500 kcmil
33097 1 x 1000 rm / 35 24 12 / 20 5,5 35 62,0 394,0 2900,0 4780,0 2000 kcmil

Continuation

597
Energy- and Power Cable / Medium Voltage Power Cables

NA2XS(F)2Y 6/10kV, 12/20kV, 18/30kV XLPE-insulated,


alu-conductor, single core, longitudinally water-tight, screened, PE-sheath
Part no. No.cores x Operation Nominal Insulation Screen Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. app. mm weight kg / km app. kg / km
mm max. kV mm mm kg / km
32621 1 x 50 rm / 16 36 18 / 30 8 16 37,0 182,0 145,0 1250,0 1
32622 1 x 70 rm / 16 36 18 / 30 8 16 38,0 182,0 203,0 1500,0 2/0
32623 1 x 95 rm / 16 36 18 / 30 8 16 40,0 182,0 276,0 1700,0 3/0
32624 1 x 120 rm / 16 36 18 / 30 8 16 42,0 182,0 348,0 1800,0 4/0
32625 1 x 150 rm / 25 36 18 / 30 8 25 43,0 283,0 435,0 2050,0 300 kcmil
32626 1 x 185 rm / 25 36 18 / 30 8 25 45,0 283,0 537,0 2150,0 350 kcmil
32627 1 x 240 rm / 25 36 18 / 30 8 25 47,0 283,0 696,0 2400,0 500 kcmil
32628 1 x 300 rm / 25 36 18 / 30 8 25 50,0 283,0 870,0 2700,0 600 kcmil
32629 1 x 400 rm / 35 36 18 / 30 8 35 53,0 394,0 1160,0 3200,0 750 kcmil
32630 1 x 500 rm / 35 36 18 / 30 8 35 56,0 394,0 1450,0 3555,0 1000 kcmil
31219 1 x 630 rm / 35 36 18 / 30 8 35 58,0 394,0 1827,0 3790,0 1250 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

Suitable medium voltage connection sleeves can


be found in our Cable Accessories catalogue.

598
Energy- and Power Cable / Medium Voltage Power Cables

NA2XS(FL)2Y 6/10kV, 12/20kV, 18/30kVXLPE-insulated,


alu-conductor, single core, longitudinally and crosswise water-tight, screened, PE-sheath

Technical data Cable structure Properties


XLPE-insulated power cables to Aluminium-conductor, to The materials used in manufacture are
DIN VDE 0276 part 620, HD 620 S2 DIN VDE 0295 cl.2, multi-wire, cadmium-free and contain no silicone
and IEC 60502 BS 6360 cl.2, IEC 60228 cl.2 and free from substances harmful to
Temperature range Inner semi-conducting coating the wetting properties of lacquers
during installation up to -20C Core insulation of cross-linked polyethylene Installation notes
Operating temperature (XLPE), compound type DIX8 to HD 620 S2 To guarantee an optimum on operating
max. + 90C Outer extrusion of semi-conducting reliability the extruded semi-conductive
Short circuit temperature coating spliced with the XLPE-insulation layer is spliced with the insulation for long
250C (short circuit duration max. 5 s) Longitudinally water-tight, conductive duration. For this reason we recommend
Nominal voltages wrapping a peeling tool for installation.
U0/U 6/10 kV, 12/20 kV, 18/30 kV Screen: Braiding of copper wires with
Operating voltages one or two tapes applied helically Note
for 6/10 kV = max. 12 kV Longitudinally water-tight wrapping rm = round conductor, multi-wire
for 12/20 kV = max. 24 kV Aluminium tape spliced with PE sheath Further types and dimensions on request.
for 18/30 kV = max. 36 kV Outer sheath of PE AWG sizes are approximate equivalent
Test voltages compound type DMP2 to HD 620 S2 values. The actual cross-section is in mm.
for 6/10 kV = 15 kV Sheath colour black
for 12/20 kV = 30 kV Sheath wall thickness
for 18/30 kV = 45 kV nominal value 2,5 mm
Minimum bending radius
15x cable
Power ratings
see Technical Informations

Application
Installation primarily for power utility grids and in cable ducts, outdoors, underground and in water, and also on pallets for manufacturing plants,
switchgear and power stations. The resistant Al/PE-laminated sheathing acts as a cross water barrier. It inhibits the diffusion of water. In case of
sheathing damage, water impact is contained at the flaw. The cable can be severely mechanically stressed during installation and operation. The PE
sheathing is not flame-retardant to DIN EN 60332-1-2. The internal conductive layer between conductor and VPE insulation and the adherent external
conductive layer on the VPE insulation guarantees a design with high operational safety and no partial discharge.

Part no. No.cores x Operation Nominal Insulation Screen Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. app. mm weight kg / km app. kg / km
mm max. kV mm mm kg / km
38062 1 x 50 rm / 16 12 6 / 10 3,4 16 30,0 182,0 145,0 710,0 1
38063 1 x 70 rm / 16 12 6 / 10 3,4 16 32,0 182,0 203,0 890,0 2/0
38064 1 x 95 rm / 16 12 6 / 10 3,4 16 33,0 182,0 276,0 1100,0 3/0
38065 1 x 120 rm / 16 12 6 / 10 3,4 16 34,0 182,0 348,0 1330,0 4/0
38066 1 x 150 rm / 25 12 6 / 10 3,4 25 36,0 283,0 435,0 1450,0 300 kcmil

Q
38067 1 x 185 rm / 25 12 6 / 10 3,4 25 38,0 283,0 537,0 1580,0 350 kcmil
38068 1 x 240 rm / 25 12 6 / 10 3,4 25 40,0 283,0 696,0 1780,0 500 kcmil
38069 1 x 300 rm / 25 12 6 / 10 3,4 25 42,0 283,0 870,0 1990,0 600 kcmil
38070 1 x 400 rm / 35 12 6 / 10 3,4 35 46,0 394,0 1160,0 2320,0 750 kcmil
38071 1 x 500 rm / 35 12 6 / 10 3,4 35 49,0 394,0 1450,0 2690,0 1000 kcmil
38072 1 x 630 rm / 35 12 6 / 10 3,4 35 51,0 394,0 1827,0 3160,0 1250 kcmil
38073 1 x 50 rm / 16 24 12 / 20 5,5 16 35,0 182,0 145,0 870,0 1
38074 1 x 70 rm / 16 12 12 / 20 5,5 16 36,0 182,0 203,0 1060,0 2/0
38075 1 x 95 rm / 16 24 12 / 20 5,5 16 38,0 182,0 276,0 1280,0 3/0
38076 1 x 120 rm / 16 24 12 / 20 5,5 16 39,0 182,0 348,0 1520,0 4/0
33089 1 x 150 rm / 25 24 12 / 20 5,5 25 41,0 283,0 435,0 1650,0 300 kcmil
38077 1 x 185 rm / 25 24 12 / 20 5,5 25 43,0 283,0 537,0 1800,0 350 kcmil
38078 1 x 240 rm / 25 24 12 / 20 5,5 25 45,0 283,0 696,0 2000,0 500 kcmil
38079 1 x 300 rm / 25 24 12 / 20 5,5 25 47,0 283,0 870,0 2230,0 600 kcmil
38080 1 x 400 rm / 35 24 12 / 20 5,5 35 50,0 394,0 1160,0 2580,0 750 kcmil
38081 1 x 500 rm / 35 24 12 / 20 5,5 35 54,0 394,0 1450,0 2980,0 1000 kcmil
38082 1 x 630 rm / 35 24 6 / 10 5,5 35 55,0 394,0 1827,0 3480,0 1250 kcmil

Continuation

599
Energy- and Power Cable / Medium Voltage Power Cables

NA2XS(FL)2Y 6/10kV, 12/20kV, 18/30kVXLPE-insulated,


alu-conductor, single core, longitudinally and crosswise water-tight, screened, PE-sheath
Part no. No.cores x Operation Nominal Insulation Screen Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. app. mm weight kg / km app. kg / km
mm max. kV mm mm kg / km
33084 1 x 50 rm / 16 36 18 / 30 8 16 39,0 182,0 145,0 1100,0 1
33085 1 x 70 rm / 16 36 18 / 30 8 16 40,0 182,0 203,0 1300,0 2/0
38083 1 x 95 rm / 16 36 18 / 30 8 16 42,0 182,0 276,0 1530,0 3/0
38084 1 x 120 rm / 16 36 18 / 30 8 16 44,0 182,0 348,0 1780,0 4/0
38085 1 x 150 rm / 25 36 18 / 30 8 25 45,0 283,0 435,0 1920,0 300 kcmil
38086 1 x 185 rm / 25 36 18 / 30 8 25 47,0 283,0 537,0 2080,0 350 kcmil
38087 1 x 240 rm / 25 36 10 / 30 8 25 49,0 283,0 696,0 2300,0 500 kcmil
38088 1 x 300 rm / 25 36 18 / 30 8 25 52,0 283,0 870,0 2550,0 600 kcmil
38089 1 x 400 rm / 35 36 18 / 30 8 35 55,0 394,0 1160,0 2960,0 750 kcmil
38090 1 x 500 rm / 35 36 18 / 30 8 35 30,0 394,0 1450,0 3380,0 1000 kcmil
38091 1 x 630 rm / 35 36 18 / 30 8 35 60,0 394,0 1827,0 3900,0 1250 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

600
Energy- and Power Cable / Medium Voltage Power Cables

NYFGY 3 x ... 3,6/6kV Flat wire sheating, PVC-sheath

Technical data Cable structure Properties


Three core PVC-insulated cables Bare copper-conductor, to The materials used in manufacture are
to DIN VDE 0271 and IEC 60502 DIN VDE 0295 cl.2, multi-wire, cadmium-free and contain no silicone
Temperature range BS 6360 cl.2, IEC 60228 cl.2 and free from substances harmful to
during installation up to -5C Core insulation of PVC the wetting properties of lacquers
Operating temperature 3 cores stranded Tests
max. +70C Wrapping self-extinguishing and flame retardant
Short circuit temperature Inner sheath of PVC acc. to DIN VDE 0482-332-1-2,
(short circuit duration max. 5 s) Armour of galvanized steel DIN EN 60332-1-2, IEC 60332-1 (equivalent
+160C wires with counter helix DIN VDE 0472 part 804 test method B)
Nominal voltages U0/U 3,6/6 kV Outer sheath of PVC
Operating voltages max. 7,2 kV Sheath colour red Note
Test voltages 11 kV sm = sectional conductor, multi-wire
Minimum bending radius AWG sizes are approximate equivalent
15x cable values. The actual cross-section is in mm.
Application
Indoors and in cable ducts, outdoors with protected laying, underground for power stations, industrial systems and switchgear, whenever increased
mechanical protection is required or whenever higher drag forces are expected during assembly and operation.

Part no. No.cores x Insulation Sheath Outer Cop. Weight AWG-No.


cross-sec. thickness thickness min. - max. weight app. kg / km
mm mm Nominal value kg / km
mm
34187 3 x 25 sm 3,4 2,0 34,0 - 42,0 720,0 2640,0 4
34188 3 x 35 sm 3,4 2,1 36,0 - 43,0 1008,0 2680,0 2
34189 3 x 50 sm 3,4 2,2 38,0 - 46,0 1440,0 3205,0 1
34190 3 x 70 sm 3,4 2,3 41,0 - 49,0 2016,0 4085,0 2/0
34191 3 x 95 sm 3,4 2,4 45,0 - 53,0 2736,0 5060,0 3/0
34192 3 x 120 sm 3,4 2,6 48,0 - 56,0 3456,0 5950,0 4/0
34193 3 x 150 sm 3,4 2,7 51,0 - 59,0 4320,0 6930,0 300 kcmil
34194 3 x 185 sm 3,4 2,8 55,0 - 64,0 5328,0 8240,0 350 kcmil
34195 3 x 240 sm 3,4 2,9 59,0 - 68,0 6912,0 10100,0 500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

601
Energy- and Power Cable / Medium Voltage Power Cables

N2XSEY 3 x ... 6/10kV XLPE-insulated, Cu-conductor, PVC-sheath

Technical data Cable structure Properties


Three core XLPE-insulated Bare copper-conductor, to The materials used in manufacture are
power cables to DIN VDE 0276 DIN VDE 0295 cl.2, multi-wire, cadmium-free and contain no silicone
and IEC 60502 BS 6360 cl.2, IEC 60228 cl.2 and free from substances harmful to
Temperature range Inner semi-conducting coating the wetting properties of lacquers
during installation up to -5C Core insulation of cross-linked polyethylene Tests
Operating temperature (XLPE) self-extinguishing and flame retardant
max. +90C Outer extrusion of semi-conducting coating acc. to DIN VDE 0482-332-1-2,
Short circuit temperature spliced with the XLPE-insulation DIN EN 60332-1-2, IEC 60332-1 (equivalent
core +250C Conductive wrapping DIN VDE 0472 part 804 test method B)
screen +350C (duration) Screen: Braiding of copper wires with one Installation notes
(short circuit duration max. 5 s) or two tapes applied helically To guarantee an optimum on operating
Nominal voltages U0/U 6/10 kV 3 cores stranded reliability the extruded semi-conductive
Operating voltages max. 12 kV Extruded sheath over three cores layer is spliced with the insulation for long
Test voltages 15 kV Outer sheath of PVC duration. For this reason we recommend
Test voltages d.c. 48 kV compound type DMV6 to HD 620 S2 a peeling tool for installation.
Minimum bending radius Sheath colour red
15x cable Note
Tests rm = round conductor, multi-wire
acc. to DIN VDE 0276 and IEC 60502 AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
For laying in earth: For ground thermal
resistivity of 1 Kxm/W, laying depth 0,7 m,
ground temperature 20C, EVU load
grade 0,7.
For laying in air: Air temperature 30C, EVU
load grade 1,0.
Conversion factors for laying in earth
especially for laying in bundle form and
other requirements are noted in
DIN VDE 0298 part 2 and 0276 part 1000.
Conversion factors for laying in air
Air temperature/Conversion factor
15C/1,12; 20C/1,08; 25C/1,04;
30C/1,0; 35C/0,96; 35C/0,96; 40C/
0,91; 45C/0,87; 50C/0,82;

Application
Suitable for installation in indoors and in cable ducts, outdoors with protected laying, as well as for laying on racks for industrial and switching systems
and power plants. Limited use when buried in the earth if the PVC outer sheath could be damaged by high mechanical stress.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.

Part no. No.cores x Insulation Screen Sheath Outer Cop. Weight AWG-No.
cross-sec. thickness cross-sec. thickness app. mm weight app. kg / km
mm mm mm Nominal value kg / km
mm
34339 3 x 25 rm / 16 3,4 16 2,5 43,0 1046,0 2850,0 4
34340 3 x 35 rm / 16 3,4 16 2,5 48,0 1210,0 3300,0 2
34341 3 x 50 rm / 16 3,4 16 2,5 50,0 1671,0 3750,0 1
34342 3 x 70 rm / 16 3,4 16 2,6 54,0 2250,0 4650,0 2/0
34343 3 x 95 rm / 16 3,4 16 2,8 58,0 2995,0 5700,0 3/0
34344 3 x 120 rm / 16 3,4 16 2,9 61,0 3715,0 6700,0 4/0
34345 3 x 150 rm / 25 3,4 25 3,0 65,0 4638,0 7900,0 300 kcmil
34346 3 x 185 rm / 25 3,4 25 3,1 68,0 5645,0 9200,0 350 kcmil
34347 3 x 240 rm / 25 3,4 25 3,3 74,0 7274,0 11450,0 500 kcmil
34348 3 x 300 rm / 25 3,4 25 3,3 79,0 9160,0 14450,0 600 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

602
Energy- and Power Cable / Medium Voltage Power Cables

N2XSEH 3 x ... 6/10kV XLPE-insulated, halogen-free

Technical data Cable structure Properties


Three core XLPE-insulated power cables to Bare copper-conductor, to Halogen-free, no liberation of
DIN VDE 0276 and IEC 60502 DIN VDE 0295 cl.2, multi-wire, corrosive or toxic gases
Temperature range BS 6360 cl.2, IEC 60228 cl.2 Limited propagation of fire
during installation up to -20C Inner semi-conducting coating Low smoke development, Ozone resistant
Operating temperature Core insulation of cross-linked Installation notes
max. +90C Polyethylene (XLPE) To guarantee an optimum on operating
Short circuit temperature Outer extrusion of semi-conducting coating reliability the extruded semi-conductive
core +250C spliced with the XLPE-insulation layer is spliced with the insulation for long
screen + 350C Conductive wrapping duration. For this reason we recommend
(short circuit duration max. 5 s) Screen: Braiding of copper wires with one a peeling tool for installation.
Nominal voltages U0/U 6/10 kV or two tapes applied helically Tests
Operating voltages max. 12 kV 3 cores stranded self-extinguishing and flame retardant
Test voltages 15 kV Extruded sheath over three cores acc. to DIN VDE 0482-332-1-2,
Test voltages d.c. 48 kV outer sheath halogen-free DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius Sheath colour black DIN VDE 0472 part 804 test method B)
15x cable LS0H = Low Smoke Zero Halogen Corrosiveness of combustion gases
Tests acc. to DIN VDE 0482 part 267,
acc. to DIN VDE 0276 and IEC 60502 DIN EN 50267-2-2, IEC 60754-2
(equivalent DIN VDE 0472 part 813)
Halogen-free acc. to DIN VDE 0482
part 267, DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)

Note
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
Suitable for installation in indoors and in cable ducts, outdoors as well as for laying on racks for industrial and switching systems and power plants.
Limited use when buried in the earth if the outer sheath could be damaged by high mechanical stress.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.

Part no. No.cores x Insulation Screen Sheath Outer Cop. Weight AWG-No.
cross-sec.
mm
thickness
mm
cross-sec.
mm
thickness
Nominal value
app. mm weight
kg / km
app. kg / km
Q
mm
38041 3 x 50 rm / 16 3,4 16 2,5 50,0 1670,0 3800,0 1
38042 3 x 70 rm / 16 3,4 16 2,5 54,0 2250,0 4650,0 2/0
38043 3 x 95 rm / 16 3,4 16 2,5 58,0 2995,0 5700,0 3/0
38044 3 x 120 rm / 16 3,4 16 2,5 61,0 3715,0 6800,0 4/0
38045 3 x 150 rm / 25 3,4 25 2,5 65,0 4635,0 7900,0 300 kcmil
38046 3 x 185 rm / 25 3,4 25 2,5 68,0 5645,0 9350,0 350 kcmil
38047 3 x 240 rm / 25 3,4 25 2,5 74,0 7274,0 11450,0 500 kcmil

Dimensions and specifications may be changed without prior notice. (RQ03)

603
604
DATA, NETWORK & BUS TECHNOLOGY

Fiber optic cables 606

Copper data cables 652

BUS cables 684

605
606
FIBER OPTIC CABLES HELUCOM

Designation Drag chain capability Page

Fiber optic installation cable I-VH, I-V11Y, I-VHH,I-V11Y11Y 608

Fiber optic breakout cable I-V(ZN)HH 609

Fiber optic mini-breakout cable I-V(ZN)H 610

LWK indoor cable loose tube I-D(ZN)H 611

Fiber optic universal mini-breakout cable A/I-VQ(ZN)BH 612

HELUCOM pact fiber optic universal cable A/IDQ(ZN)BH 613

HELUCOM pact fiber optic universal cable A/IDQ(ZN)BH OM3 + OM4 614

Fiber optic universal cable A/I-DQ(ZN)BH central 615

Fiber optic universal cable A/I-DQ(ZN)BH stranded 616

Fiber optic with functionality A-DQ(ZN)BH E30 617

Fiber optic cable with functionality A/I-D(ZN)BH(SR)H FS90 618

Fiber optic outdoor cable A-DQ(ZN)2Y, central 619

Fiber optic outdoor cable A-DQ(ZN)2Y, stranded 620

HELUCOM pact fiber optic outdoor cable A-DQ(ZN)B2Y, central



621

Fiber optic outdoor cable A-DQ(ZN)B2Y, central 622

Fiber optic outdoor A-DQ(ZN)B2Y; stranded 623

Fiber optic outdoor cable HELUCOM pact A-DQ(ZN)B2Y fiber combination 624

Fiber optic outdoor cable HELUCOM A-DQ(ZN)B2Y, fibre combination, stranded



625

Fiber optic outdoor cable A-DF(ZN)2Y 626

Fiber optic outdoor cable A-DF(ZN)B2Y 627

Fiber optic outdoor cable A-DF(ZN)2Y4Y 628

Fiber optic outdoor cable Micro A-DQ2Y, central 629

Fiber optic outdoor cable Micro A-DQ2Y, stranded 630

Fiber optic outdoor cable A-DQ(ZN)SR2Y 631

Fiber optic outdoor cable A-DF(ZN)2Y(SR)2Y 632

Fiber optic outdoor cable hybrid A-DSQ(ZN)B2Y 633

Fiber optic outdoor cable hybrid A-DSF(L)(ZN)2Y 634

Fiber optic overhead cable metal-free ADSS 635

Fiber optic cable mobile, easy-to-wind A-V(ZN)11Y 636

Fiber optic cable mobile, flexible A-V(ZN)YY

Fiber optic cable flexible AT-V(ZN)H(ZN)11Y, AT-V(ZN)Y(ZN)Y


637

638
R
Fiber optic cable flexible AT-V(ZN)YY 639

Fiber optic cable outdoor apportionable AT-V(ZN)HH(BN)2Y 640

Fiber optic cable industry AT-VYY 641

Fiber optic cable industry HCS I-VH, I-VHH 642

Fiber optic breakout cable industry HCS AT-V(ZN)HH 643

Fiber optic breakout cable industry HCS I-V(ZN)YY 644

Fiber optic breakout cable industry HCS I-V(ZN)Y11Y 645

Fiber optic breakout cable industry HCS AT-VQH(ZN)B2Y 646

Fiber optic universal cable industry HCS A/IDQ(ZN)BH 647

Plastic fiber cable industry I-V2Y, I-V2Y(ZN)11Y 648

Plastic fiber cable industry I-V4Y(ZN)11Y 649

607
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Indoor Cable


acc. DIN VDE 0888
I-VH, I-V11Y, I-VHH, I-V11Y11Y

Cable structure Temperature range Other data


Core type: Composite buffered Laying, min.: 0C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Aramide Laying, max.: +50C Halogen-free acc. to 60754-2
Outer sheath material: FRNC Operating, min.: 0C Flame-resistance acc. to IEC 60332-1
Outer sheath colour: Yellow Operating, max.: +60C Smoke density acc. to IEC 61034

Designation No. of Fibre type Fibre category Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres app. mm tensile bending app. MJ / m transverse kg / km
force N radius pressure
mm N / cm
I-VH 1 Multimode G50/125 OM2 2,6 300 40 0,17 10 8,7 80783
I-VH 1 Multimode G62.5/125 OM1 2,6 300 40 0,17 10 8,7 80782
I-VH 1 Single-mode E9/125 ITU-T G.652 2,6 300 40 0,17 10 8,7 80784
I-VH 2 Multimode G50/125 OM2 2,6 x 5,6 400 40 0,24 10 17,5 80316
I-VH 2 Multimode G50/125 OM3 2,6 x 5,6 400 40 0,24 10 17,5 804256
I-VH 2 Multimode G62.5/125 OM1 2,6 x 5,6 400 40 0,24 10 17,5 80699
I-VH 2 Single-mode E9/125 ITU-T G.652 2,6 x 5,6 400 40 0,24 10 17,5 80785
I-V11Y 2 Multimode G50/125 OM2 2,6 x 5,6 400 40 2,80 20 14,0 82408
I-V11Y 2 Multimode G62.5/125 OM1 2,6 x 5,6 400 40 2,80 20 14,0 82410
I-V11Y 2 Single-mode E9/125 ITU-T G.652 2,6 x 5,6 400 40 2,80 20 14,0 82411
I-VHH 2 Multimode G50/125 OM2 3,6 x 6,2 600 50 0,57 20 20,0 80789
I-VHH 2 Multimode G50/125 OM3 3,6 x 6,2 600 50 0,57 20 20,0 804254
I-VHH 2 Multimode G62.5/125 OM1 3,6 x 6,2 600 50 0,57 20 20,0 80790
I-VHH 2 Single-mode E9/125 ITU-T G.652 3,6 x 6,2 600 50 0,57 20 20,0 80791
I-V11Y11Y 2 Multimode G50/125 OM2 3,6 x 6,2 600 60 4,20 20 16,0 82409
I-V11Y11Y 2 Multimode G62.5/125 OM1 3,6 x 6,2 600 60 4,20 20 16,0 81900
I-V11Y11Y 2 Single-mode E9/125 ITU-T G.652 3,6 x 6,2 600 60 4,20 20 16,0 82412

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM one-fibre and two-fibre (duplex) cables are used for fixed indoor installation, such as in cable ducts. These cables are also used as
ready-made cables (pigtails) that are spliced to fixed cables or as connection cables (jumper cable) as well as for switch frames. The small diameter
and the high flexibility make these cables ideal for the application in switch frames as well as for the connection of terminals.

608
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Breakout-Cable


acc. DIN VDE 0888
I-V(ZN)HH

Cable structure Temperature range Other data


Core type: Composite buffered Laying, min.: 0C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Aramide Laying, max.: +50C Halogen-free acc. to 60754-2
Outer sheath material: FRNC Operating, min.: 0C Flame-resistance acc. to IEC 60332-1 and
Outer sheath colour: Yellow Operating, max.: +60C IEC 60332-3
Smoke density acc. to IEC 61034

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
I-V(ZN)HH 2 Multimode G50/125 OM2 1 7,1 1000 270,0 1,00 150 40,0 80743
I-V(ZN)HH 2 Multimode G62.5/125 OM1 1 7,1 1000 270,0 1,00 150 40,0 80799
I-V(ZN)HH 2 Single-mode E9/125 ITU-T G.652 1 7,1 1000 270,0 1,00 150 40,0 80813
I-V(ZN)HH 4 Multimode G50/125 OM2 1 7,1 1000 270,0 1,00 150 45,0 80753
I-V(ZN)HH 4 Multimode G62.5/125 OM1 1 7,1 1000 270,0 1,00 150 45,0 80800
I-V(ZN)HH 4 Single-mode E9/125 ITU-T G.652 1 7,1 1000 270,0 1,00 150 45,0 80814
I-V(ZN)HH 6 Multimode G50/125 OM2 1 8,4 1350 270,0 1,25 150 70,0 80754
I-V(ZN)HH 6 Multimode G62.5/125 OM1 1 8,4 1350 270,0 1,25 150 70,0 80769
I-V(ZN)HH 6 Single-mode E9/125 ITU-T G.652 1 8,4 1350 270,0 1,25 150 70,0 80815
I-V(ZN)HH 8 Multimode G50/125 OM2 1 9,3 1500 270,0 1,50 150 100,0 80688
I-V(ZN)HH 8 Multimode G62.5/125 OM1 1 9,3 1500 270,0 1,50 150 100,0 80801
I-V(ZN)HH 8 Single-mode E9/125 ITU-T G.652 1 9,3 1500 270,0 1,50 150 100,0 80816
I-V(ZN)HH 12 Multimode G50/125 OM2 1 9,6 2350 270,0 1,85 150 165,0 80795
I-V(ZN)HH 12 Multimode G62.5/125 OM1 1 9,6 2350 270,0 1,85 150 165,0 80803
I-V(ZN)HH 12 Single-mode E9/125 ITU-T G.652 1 9,6 2350 270,0 1,85 150 165,0 80818
I-V(ZN)HH 16 Multimode G50/125 OM2 1 15,0 2400 270,0 2,40 150 170,0 80796
I-V(ZN)HH 16 Multimode G62.5/125 OM1 1 15,0 2400 270,0 2,40 150 170,0 80804
I-V(ZN)HH 16 Single-mode E9/125 ITU-T G.652 1 15,0 2400 270,0 2,40 150 170,0 80819
I-V(ZN)HH 24 Multimode G50/125 OM2 1 17,5 2400 330,0 3,20 150 220,0 80798
I-V(ZN)HH 24 Multimode G62.5/125 OM1 1 17,5 2400 330,0 3,20 150 220,0 80806
I-V(ZN)HH 24 Single-mode E9/125 ITU-T G.652 1 17,5 2400 320,0 3,20 150 220,0 80821

Dimensions and specifications may be changed without prior notice.

Application
HELUCOM breakout cables are designed to replace splicing on-site. They are mainly used in indoor applications for small and medium transmission
lines. The fibre-optic connectors are be mounted directly to the individual cables. Therefore no splicing and no splice boxes are necessary. Pre-assembled
cables only need to be laid on site and are immediately functional.

609
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Minibreakout Cable


acc. DIN VDE 0888
I-V(ZN)H

Cable structure Temperature range Other data


Core type: Tight buffer Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Aramide Laying, max.: +50C Halogen-free acc. to 60754-2
Outer sheath material: FRNC Operating, min.: -10C Flame-resistance acc. to IEC 60332-1
Outer sheath colour: Orange Operating, max.: +60C Smoke density acc. to IEC 61034

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
I-V(ZN)H 2 Multimode G50/125 OM2 1 4,0 400 60,0 0,24 40 15,0 80435
I-V(ZN)H 2 Multimode G62.5/125 OM1 1 4,0 400 60,0 0,24 40 15,0 80434
I-V(ZN)H 2 Single-mode E9/125 ITU-T G.652 1 4,0 400 60,0 0,24 40 15,0 80433
I-V(ZN)H 4 Multimode G50/125 OM2 1 4,8 400 70,0 0,31 40 19,0 80432
I-V(ZN)H 4 Multimode G62.5/125 OM1 1 4,8 400 70,0 0,31 40 19,0 80431
I-V(ZN)H 4 Single-mode E9/125 ITU-T G.652 1 4,8 400 70,0 0,31 40 19,0 80430
I-V(ZN)H 6 Multimode G50/125 OM2 1 5,3 400 80,0 0,35 40 23,0 80429
I-V(ZN)H 6 Multimode G62.5/125 OM1 1 5,3 400 80,0 0,35 40 23,0 80428
I-V(ZN)H 6 Single-mode E9/125 ITU-T G.652 1 5,3 400 80,0 0,35 40 23,0 80427
I-V(ZN)H 8 Multimode G50/125 OM2 1 5,3 500 80,0 0,40 40 25,0 80426
I-V(ZN)H 8 Multimode G62.5/125 OM1 1 5,3 500 80,0 0,40 40 25,0 80425
I-V(ZN)H 8 Single-mode E9/125 ITU-T G.652 1 5,3 500 80,0 0,40 40 25,0 80424
I-V(ZN)H 10 Multimode G50/125 OM2 1 6,0 600 90,0 0,53 40 32,0 80423
I-V(ZN)H 10 Multimode G62.5/125 OM1 1 6,0 600 90,0 0,53 40 32,0 80422
I-V(ZN)H 10 Single-mode E9/125 ITU-T G.652 1 6,0 600 90,0 0,53 40 32,0 80421
I-V(ZN)H 12 Multimode G50/125 OM2 1 7,0 800 110,0 0,61 40 40,0 80420
I-V(ZN)H 12 Multimode G62.5/125 OM1 1 7,0 800 110,0 0,61 40 40,0 80419
I-V(ZN)H 12 Single-mode E9/125 ITU-T G.652 1 7,0 800 110,0 0,61 40 40,0 80418

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are used for the data network cabling in indoor applications. A big advantage of this cable type is its space-saving
construction. Similar to the breakout cable, the connector is directly mounted at the tight buffer.

610
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Indoor Cable


acc. DIN VDE 0888
I-D(ZN)H

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Aramide Laying, max.: +50C Halogen-free acc. to 60754-2
Outer sheath material: FRNC Operating, min.: -20C Flame-resistance acc. to IEC 60332-1
Outer sheath colour: Yellow Operating, max.: +60C Smoke density acc. to IEC 61034

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
I-D(ZN)H 4 Multimode G50/125 OM2 4 8,0 1200 120,0 1,50 150 65,0 80631
I-D(ZN)H 4 Multimode G62.5/125 OM1 4 8,0 1200 120,0 1,50 150 65,0 80882
I-D(ZN)H 4 Single-mode E9/125 ITU-T G.652 4 8,0 1200 120,0 1,50 150 65,0 80896
I-D(ZN)H 6 Multimode G50/125 OM2 6 8,0 1200 120,0 1,50 150 65,0 80868
I-D(ZN)H 6 Multimode G62.5/125 OM1 6 8,0 1200 120,0 1,50 150 65,0 80883
I-D(ZN)H 6 Single-mode E9/125 ITU-T G.652 6 8,0 1200 120,0 1,50 150 65,0 80897
I-D(ZN)H 8 Multimode G50/125 OM2 8 8,0 1200 120,0 1,50 150 65,0 80869
I-D(ZN)H 8 Multimode G62.5/125 OM1 8 8,0 1200 120,0 1,50 150 65,0 80884
I-D(ZN)H 8 Single-mode E9/125 ITU-T G.652 8 8,0 1200 120,0 1,50 150 65,0 80898
I-D(ZN)H 10 Multimode G50/125 OM2 10 8,0 1200 120,0 1,50 150 65,0 80793
I-D(ZN)H 10 Multimode G62.5/125 OM1 10 8,0 1200 120,0 1,50 150 65,0 80885
I-D(ZN)H 10 Single-mode E9/125 ITU-T G.652 10 8,0 1200 120,0 1,50 150 65,0 80899
I-D(ZN)H 12 Multimode G50/125 OM2 12 8,0 1200 120,0 1,50 150 65,0 80045
I-D(ZN)H 12 Multimode G62.5/125 OM1 12 8,0 1200 120,0 1,50 150 65,0 80879
I-D(ZN)H 12 Single-mode E9/125 ITU-T G.652 12 8,0 1200 120,0 1,50 150 65,0 80880
I-D(ZN)H 16 Multimode G50/125 OM2 16 8,0 1200 120,0 1,50 150 135,0 80870
I-D(ZN)H 16 Multimode G62.5/125 OM1 16 8,0 1200 120,0 1,50 150 135,0 80886
I-D(ZN)H 16 Single-mode E9/125 ITU-T G.652 16 8,0 1200 120,0 1,50 150 135,0 80900
I-D(ZN)H 24 Multimode G50/125 OM2 12 12,5 3000 190,0 2,20 200 150,0 80872
I-D(ZN)H 24 Multimode G50/125 OM2 24 9,0 1600 140,0 1,50 150 135,0 80871
I-D(ZN)H 24 Multimode G62.5/125 OM1 12 12,5 3000 190,0 2,20 200 150,0 80888
I-D(ZN)H 24 Multimode G62.5/125 OM1 24 9,0 1600 140,0 1,50 150 135,0 81246
I-D(ZN)H 24 Single-mode E9/125 ITU-T G.652 12 12,5 3000 190,0 2,20 200 150,0 80902
I-D(ZN)H 24 Single-mode E9/125 ITU-T G.652 24 9,0 1600 140,0 1,50 150 135,0 80901
I-D(ZN)H 36 Multimode G50/125 OM2 12 13,5 3000 200,0 2,20 200 160,0 80875
I-D(ZN)H 36 Multimode G62.5/125 OM1 12 13,5 3000 200,0 2,20 200 160,0 80891
I-D(ZN)H 36 Single-mode E9/125 ITU-T G.652 12 13,5 3000 200,0 2,20 200 160,0 80905
I-D(ZN)H 48 Multimode G50/125 OM2 12 13,5 3000 200,0 2,20 200 160,0 80877
I-D(ZN)H 48 Multimode G62.5/125 OM1 12 13,5 3000 200,0 2,20 200 160,0 80893
I-D(ZN)H 48 Single-mode E9/125 ITU-T G.652 12 13,5 3000 200,0 2,20 200 160,0 80907
I-D(ZN)H 60 Multimode G50/125 OM2 12 13,5 3000 200,0 2,20 200 170,0 80878
I-D(ZN)H 60 Multimode G62.5/125 OM1 12 13,5 3000 200,0 2,20 200 170,0 80894
I-D(ZN)H 60 Single-mode E9/125 ITU-T G.652 12 13,5 3000 200,0 2,20 200 170,0 80908 R
Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor cabling of
buildings and facilities. The halogen-free version is especially suitable for the application in skyscrapers, hospitals and stores as well as in facilities with
high concentration of capital goods, such as power plants, computing centers, and at locations with high security requirements, such as underground
and control stations.

611
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Indoor/Outdoor


Minibreakout Cable
acc. DIN VDE 0888
A/I-VQ(ZN)BH

Cable structure Temperature range Other data


Core type: Tight buffer Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Aramide Laying, max.: +50C Halogen-free acc. to 60754-2
Type of armouring: Glass yarns Operating, min.: -20C Flame-resistance acc. to IEC 60332-1
Outer sheath material: FRNC Operating, max.: +55C Smoke density acc. to IEC 61034
Outer sheath colour: Black UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-VQ(ZN)BH 4 Multimode G50/125 OM2 1 6,1 2000 90,0 0,35 40 40,0 82804
A/I-VQ(ZN)BH 4 Multimode G62.5/125 OM1 1 6,1 2000 90,0 0,35 40 40,0 82809
A/I-VQ(ZN)BH 4 Single-mode E9/125 ITU-T G.652 1 6,1 2000 90,0 0,35 40 40,0 82814
A/I-VQ(ZN)BH 6 Multimode G50/125 OM2 1 6,6 2000 100,0 0,41 40 47,0 82805
A/I-VQ(ZN)BH 6 Multimode G62.5/125 OM1 1 6,6 2000 100,0 0,41 40 47,0 82810
A/I-VQ(ZN)BH 6 Single-mode E9/125 ITU-T G.652 1 6,6 2000 100,0 0,41 40 47,0 82815
A/I-VQ(ZN)BH 8 Multimode G50/125 OM2 1 6,6 2000 100,0 0,43 40 51,0 82806
A/I-VQ(ZN)BH 8 Multimode G62.5/125 OM1 1 6,6 2000 100,0 0,43 40 51,0 82811
A/I-VQ(ZN)BH 8 Single-mode E9/125 ITU-T G.652 1 6,6 2000 100,0 0,43 40 51,0 82816
A/I-VQ(ZN)BH 10 Multimode G50/125 OM2 1 8,0 2000 120,0 0,61 40 65,0 82807
A/I-VQ(ZN)BH 10 Multimode G62.5/125 OM1 1 8,0 2000 120,0 0,61 40 65,0 82812
A/I-VQ(ZN)BH 10 Single-mode E9/125 ITU-T G.652 1 8,0 2000 120,0 0,61 40 65,0 82817
A/I-VQ(ZN)BH 12 Multimode G50/125 OM2 1 8,3 3000 125,0 0,71 40 70,0 82808
A/I-VQ(ZN)BH 12 Multimode G62.5/125 OM1 1 8,3 3000 125,0 0,71 40 70,0 82813
A/I-VQ(ZN)BH 12 Single-mode E9/125 ITU-T G.652 1 8,3 3000 125,0 0,71 40 70,0 82818

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are used for the data network cabling in indoor and outdoor applications. With their black UV-resistant outer
sheath and the non-metallic rodent protection, they are perfectly suited for outdoor use. A big advantage of this cable type is its space-saving
construction. Similar to the breakout cable, the connector is directly mounted at the tight buffer.

612
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Indoor/Outdoor


Cable
acc. DIN VDE 0888 pact
A/I-DQ(ZN)BH

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Glass yarns Laying, max.: +50C Halogen-free acc. to 60754-2
Type of armouring: Glass yarns Operating, min.: -20C Flame-resistance acc. to IEC 60332-1
Outer sheath material: FRNC Operating, max.: +60C Smoke density acc. to IEC 61034
Outer sheath colour: Black Longitudinally water-tight acc. to
IEC 60794-1-2-F5
UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 4 Multimode G50/125 OM2 4 7,5 1500 150,0 1,10 200 55,0 82792
A/I-DQ(ZN)BH 4 Multimode G62.5/125 OM1 4 7,5 1500 150,0 1,10 200 55,0 82796
A/I-DQ(ZN)BH 4 Single-mode E9/125 ITU-T G.652 4 7,5 1500 150,0 1,10 200 55,0 82800
A/I-DQ(ZN)BH 6 Multimode G50/125 OM2 6 7,5 1500 150,0 1,10 200 55,0 82793
A/I-DQ(ZN)BH 6 Multimode G62.5/125 OM1 6 7,5 1500 150,0 1,10 200 55,0 82797
A/I-DQ(ZN)BH 6 Single-mode E9/125 ITU-T G.652 6 7,5 1500 150,0 1,10 200 55,0 82801
A/I-DQ(ZN)BH 8 Multimode G50/125 OM2 8 7,5 1500 150,0 1,10 200 55,0 82794
A/I-DQ(ZN)BH 8 Multimode G62.5/125 OM1 8 7,5 1500 150,0 1,10 200 55,0 82798
A/I-DQ(ZN)BH 8 Single-mode E9/125 ITU-T G.652 8 7,5 1500 150,0 1,10 200 55,0 82802
A/I-DQ(ZN)BH 12 Multimode G50/125 OM2 12 7,5 1500 150,0 1,10 200 55,0 82795
A/I-DQ(ZN)BH 12 Multimode G62.5/125 OM1 12 7,5 1500 150,0 1,10 200 55,0 82799
A/I-DQ(ZN)BH 12 Single-mode E9/125 ITU-T G.652 12 7,5 1500 150,0 1,10 200 55,0 82803
A/I-DQ(ZN)BH 24 Multimode G50/125 OM2 24 8,5 1500 170,0 1,40 200 75,0 802143
A/I-DQ(ZN)BH 24 Multimode G62.5/125 OM1 24 8,5 1500 170,0 1,40 200 75,0 802144
A/I-DQ(ZN)BH 24 Single-mode E9/125 ITU-T G.652 24 8,5 1500 170,0 1,40 200 75,0 802145

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM pact fibre-optic cables have a small but robust construction. They are suitable for indoor and outdoor cabling of buildings and
facilities when space is an important argument. They are used in particular if the installation is to be done in one piece from the inside to the outside
without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are perfectly suited for
outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.

613
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Indoor/Outdoor


Cable
acc. DIN VDE 0888 pact
A/I-DQ(ZN)BH OM3+OM4

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Glass yarns Laying, max.: +50C Halogen-free acc. to 60754-2
Type of armouring: Glass yarns Operating, min.: -20C Flame-resistance acc. to IEC 60332-1
Outer sheath material: FRNC Operating, max.: +60C Smoke density acc. to IEC 61034
Outer sheath colour: Black Longitudinally water-tight acc. to
IEC 60794-1-2-F5
UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 4 Multimode G50/125 OM3 4 7,5 1500 150,0 1,10 200 55,0 802247
A/I-DQ(ZN)BH 6 Multimode G50/125 OM3 6 7,5 1500 150,0 1,10 200 55,0 802277
A/I-DQ(ZN)BH 8 Multimode G50/125 OM3 8 7,5 1500 150,0 1,10 200 55,0 802278
A/I-DQ(ZN)BH 12 Multimode G50/125 OM3 12 7,5 1500 150,0 1,10 200 55,0 802248
A/I-DQ(ZN)BH 24 Multimode G50/125 OM3 24 8,5 1500 170,0 1,40 200 75,0 802249
A/I-DQ(ZN)BH 12 Multimode G50/125 OM4 12 7,5 1500 150,0 1,10 200 55,0 804705
A/I-DQ(ZN)BH 24 Multimode G50/125 OM4 24 8,5 1500 170,0 1,40 200 75,0 804706

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM pact fibre-optic cables have a small but robust construction. They are suitable for indoor and outdoor cabling of buildings and
facilities when space is an important argument. They are used in particular if the installation is to be done in one piece from the inside to the outside
without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are perfectly suited for
outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.

614
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Indoor/Outdoor Cable


acc. DIN VDE 0888
A/I-DQ(ZN)BH, central

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Glass yarns Laying, max.: +50C Halogen-free acc. to 60754-2
Type of armouring: Glass yarns Operating, min.: -20C Flame-resistance acc. to IEC 60332-1
Outer sheath material: FRNC Operating, max.: +60C Smoke density acc. to IEC 61034
Outer sheath colour: Black Longitudinally water-tight acc. to
IEC 60794-1-2-F5
UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 4 Multimode G50/125 OM2 4 10,0 2500 150,0 1,50 300 75,0 80270
A/I-DQ(ZN)BH 4 Multimode G62.5/125 OM1 4 10,0 2500 150,0 1,50 300 75,0 80276
A/I-DQ(ZN)BH 4 Single-mode E9/125 ITU-T G.652 4 10,0 2500 150,0 1,50 300 75,0 80264
A/I-DQ(ZN)BH 6 Multimode G50/125 OM2 6 10,0 2500 150,0 1,50 300 75,0 80271
A/I-DQ(ZN)BH 6 Multimode G62.5/125 OM1 6 10,0 2500 150,0 1,50 300 75,0 80265
A/I-DQ(ZN)BH 6 Single-mode E9/125 ITU-T G.652 6 10,0 2500 150,0 1,50 300 75,0 80272
A/I-DQ(ZN)BH 8 Multimode G50/125 OM2 8 10,0 2500 150,0 1,50 300 75,0 80273
A/I-DQ(ZN)BH 8 Multimode G62.5/125 OM1 8 10,0 2500 150,0 1,50 300 75,0 80274
A/I-DQ(ZN)BH 8 Single-mode E9/125 ITU-T G.652 8 10,0 2500 150,0 1,50 300 75,0 80275
A/I-DQ(ZN)BH 12 Multimode G50/125 OM2 12 10,0 2500 150,0 1,50 300 75,0 80681
A/I-DQ(ZN)BH 12 Multimode G62.5/125 OM1 12 10,0 2500 150,0 1,50 300 75,0 80278
A/I-DQ(ZN)BH 12 Single-mode E9/125 ITU-T G.652 12 10,0 2500 150,0 1,50 300 75,0 80279
A/I-DQ(ZN)BH 16 Multimode G50/125 OM2 16 10,0 2500 150,0 1,50 300 85,0 80280
A/I-DQ(ZN)BH 16 Multimode G62.5/125 OM1 16 10,0 2500 150,0 1,50 300 85,0 80281
A/I-DQ(ZN)BH 16 Single-mode E9/125 ITU-T G.652 16 10,0 2500 150,0 1,50 300 85,0 80851
A/I-DQ(ZN)BH 24 Multimode G50/125 OM2 24 10,0 2500 150,0 1,50 300 85,0 80725
A/I-DQ(ZN)BH 24 Multimode G62.5/125 OM1 24 10,0 2500 150,0 1,50 300 85,0 82431

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor and outdoor
cabling of buildings and facilities. They are used in particular if the installation is to be done in one piece from the inside to the outside without additional
use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are perfectly suited for outdoor use. The
halogen-free outer sheath makes installation inhouse possible without any problems.

615
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Indoor/Outdoor Cable


acc. DIN VDE 0888
A/I-DQ(ZN)BH, stranded

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Strain relief elements: Glass yarns Operating, min.: -20C Flame-resistance acc. to IEC 60332-1
Type of armouring: Glass yarns Operating, max.: +60C Smoke density acc. to IEC 61034
Outer sheath material: FRNC Longitudinally water-tight acc. to
Outer sheath colour: Black IEC 60794-1-2-F5
UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 24 Multimode G50/125 OM2 12 11,0 2700 165,0 2,00 600 90,0 81495
A/I-DQ(ZN)BH 24 Multimode G62.5/125 OM1 12 11,0 2700 165,0 2,00 600 90,0 802263
A/I-DQ(ZN)BH 24 Single-mode E9/125 ITU-T G.652 12 11,0 2700 165,0 2,00 600 90,0 80846
A/I-DQ(ZN)BH 48 Multimode G50/125 OM2 12 11,0 2700 165,0 2,00 600 90,0 802261
A/I-DQ(ZN)BH 48 Multimode G62.5/125 OM1 12 11,0 2700 165,0 2,00 600 90,0 802264
A/I-DQ(ZN)BH 48 Single-mode E9/125 ITU-T G.652 12 11,0 2700 165,0 2,00 600 90,0 802266
A/I-DQ(ZN)BH 48 Single-mode E9/125 ITU-T G.652 12 11,0 2700 165,0 2,00 600 90,0 802281
A/I-DQ(ZN)BH 60 Multimode G50/125 OM2 12 11,0 2700 165,0 2,00 600 90,0 802262
A/I-DQ(ZN)BH 60 Multimode G62.5/125 OM1 12 11,0 2700 165,0 2,00 600 90,0 802265
A/I-DQ(ZN)BH 60 Single-mode E9/125 ITU-T G.652 12 11,0 2700 165,0 2,00 600 90,0 802267
A/I-DQ(ZN)BH 72 Multimode G50/125 OM2 12 11,5 2700 175,0 2,10 600 100,0 802268
A/I-DQ(ZN)BH 72 Multimode G62.5/125 OM1 12 11,5 2700 175,0 2,10 600 100,0 802271
A/I-DQ(ZN)BH 72 Single-mode E9/125 ITU-T G.652 12 11,5 2700 175,0 2,10 600 100,0 802274
A/I-DQ(ZN)BH 84 Multimode G50/125 OM2 12 12,5 3000 190,0 2,40 600 130,0 802269
A/I-DQ(ZN)BH 84 Multimode G62.5/125 OM1 12 12,5 3000 190,0 2,40 600 130,0 802272
A/I-DQ(ZN)BH 84 Single-mode E9/125 ITU-T G.652 12 12,5 3000 190,0 2,40 600 130,0 802275
A/I-DQ(ZN)BH 96 Multimode G50/125 OM2 12 12,5 3000 190,0 2,80 600 130,0 802270
A/I-DQ(ZN)BH 96 Multimode G62.5/125 OM1 12 12,5 3000 190,0 2,80 600 130,0 802273
A/I-DQ(ZN)BH 96 Single-mode E9/125 ITU-T G.652 12 12,5 3000 190,0 2,80 600 130,0 802276

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor and outdoor
cabling of buildings and facilities. They are used in particular if the installation is to be done in one piece from the inside to the outside without additional
use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are perfectly suited for outdoor use. The
halogen-free outer sheath makes installation inhouse possible without any problems.

616
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Cable with


Functionality
with reference to DIN 4102-12 FS30
A/I-DQ(ZN)BH

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -10C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Aramide Laying, max.: +50C Halogen-free acc. to 60754-2
Type of armouring: Glass yarns Operating, min.: -25C Flame-resistance acc. to IEC 60332-1
Outer sheath material: FR/LSOH Operating, max.: +60C Smoke density acc. to IEC 61034
Outer sheath colour: Red Longitudinally water-tight acc. to
IEC 60794-1-2-F5
UV-resistant
Functional integrity: E30

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 4 Multimode G50/125 OM2 4 7,8 1000 80,0 1,08 200 102,0 801217
A/I-DQ(ZN)BH 4 Multimode G62.5/125 OM1 4 7,8 1000 80,0 1,08 200 102,0 801218
A/I-DQ(ZN)BH 4 Single-mode E9/125 ITU-T G.652 4 7,8 1000 80,0 1,08 200 102,0 801219
A/I-DQ(ZN)BH 12 Multimode G50/125 OM2 12 7,8 1000 80,0 1,08 200 102,0 801220
A/I-DQ(ZN)BH 12 Multimode G62.5/125 OM1 12 7,8 1000 80,0 1,08 200 102,0 801221
A/I-DQ(ZN)BH 12 Single-mode E9/125 ITU-T G.652 12 7,8 1000 80,0 1,08 200 102,0 801190

Dimensions and specifications may be changed without prior notice.

Application
With the serie HELUCOM E30 we have realized, based on a special construction and high quality raw materials, a functional integrity according to
DIN 4102-12 E30 (30 minutes). Together with the planed accessories the cables realize the full function of the communication in areas like tunnels
or buildings for the defined period of time. On request we also can deliver cables with more than 12 fibres as stranded construction.

617
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Cable with


Functionality
with reference to IEC 60331-25 FS90
A/I-D(ZN)BH(SR)H

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Glass yarns Laying, max.: +50C Halogen-free acc. to 60754-2
Inner sheath material: FRNC Operating, min.: -20C Flame-resistance acc. to IEC 60332-1 and -3
Type of armouring: steel tape Operating, max.: +70C Smoke density acc. to IEC 61034
Outer sheath material: FR/LSOH Longitudinally water-tight acc. to
Outer sheath colour: Black IEC 60794-1-2-F5
Cable, laterally water-tight
UV-resistant
Functional integrity: IEC 60794/ IEC 60331-25

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-D(ZN)BH(SR)H 4 Multimode G50/125 OM2 4 12,7 1500 180,0 6,20 300 216,0 803917
A/I-D(ZN)BH(SR)H 4 Single-mode E9/125 ITU-T G.652 4 12,7 1500 180,0 6,20 300 216,0 803919
A/I-D(ZN)BH(SR)H 12 Multimode G50/125 OM2 12 12,7 1500 180,0 6,20 300 216,0 803918
A/I-D(ZN)BH(SR)H 12 Single-mode E9/125 ITU-T G.652 12 12,7 1500 180,0 6,20 300 216,0 803920

Dimensions and specifications may be changed without prior notice.

Application
With the serie HELUCOM FS90 we have realized, based on a special construction and high quality raw materials, a functional integrity according to
IEC 60331-25 within 90, minutes (up to 750C). Together with the planed accessories the cables realize the full function of the communication in
areas like tunnels or buildings for the defined period of time.

618
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. DIN VDE 0888
A-DQ(ZN)2Y, central

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Glass yarns Laying, max.: +50C Halogen-free acc. to 60754-2
Outer sheath material: PE Operating, min.: -20C Longitudinally water-tight acc. to
Outer sheath colour: Black Operating, max.: +60C IEC 60794-1-2-F5
UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)2Y 2 Multimode G50/125 OM2 2 8,8 1500 130,0 1,60 250 40,0 80148
A-DQ(ZN)2Y 2 Multimode G62.5/125 OM1 2 8,8 1500 130,0 1,60 250 40,0 80164
A-DQ(ZN)2Y 2 Single-mode E9/125 ITU-T G.652 2 8,8 1500 130,0 1,60 250 40,0 80131
A-DQ(ZN)2Y 4 Multimode G50/125 OM2 4 8,8 1500 130,0 1,60 250 40,0 80149
A-DQ(ZN)2Y 4 Multimode G62.5/125 OM1 4 8,8 1500 130,0 1,60 250 40,0 80165
A-DQ(ZN)2Y 4 Single-mode E9/125 ITU-T G.652 4 8,8 1500 130,0 1,60 250 40,0 80132
A-DQ(ZN)2Y 6 Multimode G50/125 OM2 6 8,8 1500 130,0 1,60 250 40,0 80150
A-DQ(ZN)2Y 6 Multimode G62.5/125 OM1 6 8,8 1500 130,0 1,60 250 40,0 80166
A-DQ(ZN)2Y 6 Single-mode E9/125 ITU-T G.652 6 8,8 1500 130,0 1,60 250 40,0 80133
A-DQ(ZN)2Y 8 Multimode G50/125 OM2 8 8,8 1500 130,0 1,60 250 40,0 80151
A-DQ(ZN)2Y 8 Multimode G62.5/125 OM1 8 8,8 1500 130,0 1,60 250 40,0 80167
A-DQ(ZN)2Y 8 Single-mode E9/125 ITU-T G.652 8 8,8 1500 130,0 1,60 250 40,0 80134
A-DQ(ZN)2Y 12 Multimode G50/125 OM2 12 8,8 1500 130,0 1,60 250 40,0 80153
A-DQ(ZN)2Y 12 Multimode G62.5/125 OM1 12 8,8 1500 130,0 1,60 250 40,0 80169
A-DQ(ZN)2Y 12 Single-mode E9/125 ITU-T G.652 12 8,8 1500 130,0 1,60 250 40,0 80136
A-DQ(ZN)2Y 16 Multimode G50/125 OM2 16 8,8 1500 130,0 1,80 250 70,0 80154
A-DQ(ZN)2Y 16 Multimode G62.5/125 OM1 16 8,8 1500 130,0 1,80 250 70,0 80170
A-DQ(ZN)2Y 16 Single-mode E9/125 ITU-T G.652 16 8,8 1500 130,0 1,80 250 70,0 80137
A-DQ(ZN)2Y 24 Multimode G50/125 OM2 24 8,8 1500 130,0 1,80 250 70,0 80155
A-DQ(ZN)2Y 24 Multimode G62.5/125 OM1 24 8,8 1500 130,0 1,80 250 70,0 80171
A-DQ(ZN)2Y 24 Single-mode E9/125 ITU-T G.652 24 8,8 1500 130,0 1,80 250 70,0 80138

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount. Around a central grooved cable, there is a
composite of glass yarns and swelling fleece with characteristics that ensure the actual strain relief and waterproofing in longitudinal direction of the
cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This construction is particularly used in
underground, tubes and channel areas, where rodent infestation is not to be expected.

619
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. DIN VDE 0888
A-DQ(ZN)2Y, stranded

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Strain relief elements: Glass yarns Operating, min.: -20C Longitudinally water-tight acc. to
Outer sheath material: PE Operating, max.: +60C IEC 60794-1-2-F5
Outer sheath colour: Black UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)2Y 24 Multimode G50/125 OM2 12 10,0 2500 200,0 2,50 400 70,0 80156
A-DQ(ZN)2Y 24 Multimode G62.5/125 OM1 12 10,0 2500 200,0 2,50 400 70,0 80172
A-DQ(ZN)2Y 24 Single-mode E9/125 ITU-T G.652 12 10,0 2500 200,0 2,50 400 70,0 80139
A-DQ(ZN)2Y 36 Multimode G50/125 OM2 12 10,0 2500 200,0 2,50 400 70,0 80448
A-DQ(ZN)2Y 36 Multimode G62.5/125 OM1 12 10,0 2500 200,0 2,50 400 70,0 80449
A-DQ(ZN)2Y 36 Single-mode E9/125 ITU-T G.652 12 10,0 2500 200,0 2,50 400 70,0 80450
A-DQ(ZN)2Y 48 Multimode G50/125 OM2 12 10,0 2500 200,0 2,50 400 70,0 80447
A-DQ(ZN)2Y 48 Multimode G62.5/125 OM1 12 10,0 2500 200,0 2,50 400 70,0 80446
A-DQ(ZN)2Y 48 Single-mode E9/125 ITU-T G.652 12 10,0 2500 200,0 2,50 400 70,0 80445
A-DQ(ZN)2Y 60 Multimode G50/125 OM2 12 10,0 2500 200,0 2,50 400 70,0 80159
A-DQ(ZN)2Y 60 Multimode G62.5/125 OM1 12 10,0 2500 200,0 2,50 400 70,0 80175
A-DQ(ZN)2Y 60 Single-mode E9/125 ITU-T G.652 12 10,0 2500 200,0 2,50 400 70,0 80142
A-DQ(ZN)2Y 72 Multimode G50/125 OM2 12 10,5 2500 210,0 2,60 400 75,0 80444
A-DQ(ZN)2Y 72 Multimode G62.5/125 OM1 12 10,5 2500 210,0 2,60 400 75,0 80443
A-DQ(ZN)2Y 72 Single-mode E9/125 ITU-T G.652 12 10,5 2500 210,0 2,60 400 75,0 80442
A-DQ(ZN)2Y 84 Multimode G50/125 OM2 12 11,5 2700 230,0 3,30 400 110,0 80160
A-DQ(ZN)2Y 84 Multimode G62.5/125 OM1 12 11,5 2700 230,0 3,30 400 110,0 80176
A-DQ(ZN)2Y 84 Single-mode E9/125 ITU-T G.652 12 11,5 2700 230,0 3,30 400 110,0 80143
A-DQ(ZN)2Y 96 Multimode G50/125 OM2 12 11,5 2700 230,0 3,30 400 110,0 80441
A-DQ(ZN)2Y 96 Multimode G62.5/125 OM1 12 11,5 2700 230,0 3,30 400 110,0 80440
A-DQ(ZN)2Y 96 Single-mode E9/125 ITU-T G.652 12 11,5 2700 230,0 3,30 400 110,0 80439
A-DQ(ZN)2Y 108 Multimode G50/125 OM2 12 13,0 2700 260,0 4,00 400 130,0 80161
A-DQ(ZN)2Y 108 Multimode G62.5/125 OM1 12 13,0 2700 260,0 4,00 400 130,0 80177
A-DQ(ZN)2Y 108 Single-mode E9/125 ITU-T G.652 12 13,0 2700 260,0 4,00 400 130,0 80144
A-DQ(ZN)2Y 120 Multimode G50/125 OM2 12 13,0 2700 260,0 4,00 400 130,0 80162
A-DQ(ZN)2Y 120 Multimode G62.5/125 OM1 12 13,0 2700 260,0 4,00 400 130,0 80178
A-DQ(ZN)2Y 120 Single-mode E9/125 ITU-T G.652 12 13,0 2700 260,0 4,00 400 130,0 80146
A-DQ(ZN)2Y 144 Multimode G50/125 OM2 12 14,0 2700 280,0 5,00 400 150,0 80438
A-DQ(ZN)2Y 144 Multimode G62.5/125 OM1 12 14,0 2700 280,0 5,00 400 150,0 80437
A-DQ(ZN)2Y 144 Single-mode E9/125 ITU-T G.652 12 14,0 2700 280,0 5,00 400 150,0 80436

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount and extremely tension-resistant. Around a stranded
grooved cable and filler elements, there is a swelling fleece with characteristics that ensure strain relief and waterproofing in longitudinal direction of
the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This construction is particularly used in
underground, tubes and channel areas, where above-average tensile stresses and/or transverse compressions occur, but rodent infestation is not to
be expected.

620
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. DIN VDE 0888 pact
A-DQ(ZN)B2Y, central

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Glass yarns Laying, max.: +50C Halogen-free acc. to 60754-2
Type of armouring: Glass yarns Operating, min.: -20C Longitudinally water-tight acc. to
Outer sheath material: PE Operating, max.: +60C IEC 60794-1-2-F5
Outer sheath colour: Black UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)B2Y 2 Multimode G50/125 OM2 2 7,5 1500 150,0 1,60 300 40,0 800754
A-DQ(ZN)B2Y 2 Multimode G62.5/125 OM1 2 7,5 1500 150,0 1,60 300 40,0 802131
A-DQ(ZN)B2Y 2 Single-mode E9/125 ITU-T G.652 2 7,5 1500 150,0 1,60 300 40,0 802137
A-DQ(ZN)B2Y 4 Multimode G50/125 OM2 4 7,5 1500 150,0 1,60 300 40,0 800755
A-DQ(ZN)B2Y 4 Multimode G62.5/125 OM1 4 7,5 1500 150,0 1,60 300 40,0 802132
A-DQ(ZN)B2Y 4 Single-mode E9/125 ITU-T G.652 4 7,5 1500 150,0 1,60 300 40,0 802138
A-DQ(ZN)B2Y 6 Multimode G50/125 OM2 6 7,5 1500 150,0 1,60 300 40,0 800756
A-DQ(ZN)B2Y 6 Multimode G62.5/125 OM1 6 7,5 1500 150,0 1,60 300 40,0 802133
A-DQ(ZN)B2Y 6 Single-mode E9/125 ITU-T G.652 6 7,5 1500 150,0 1,60 300 40,0 802139
A-DQ(ZN)B2Y 8 Multimode G50/125 OM2 8 7,5 1500 150,0 1,60 300 40,0 800757
A-DQ(ZN)B2Y 8 Multimode G62.5/125 OM1 8 7,5 1500 150,0 1,60 300 40,0 802134
A-DQ(ZN)B2Y 8 Single-mode E9/125 ITU-T G.652 8 7,5 1500 150,0 1,60 300 40,0 802140
A-DQ(ZN)B2Y 12 Multimode G50/125 OM2 12 7,5 1500 150,0 1,60 300 40,0 800759
A-DQ(ZN)B2Y 12 Multimode G62.5/125 OM1 12 7,5 1500 150,0 1,60 300 40,0 802135
A-DQ(ZN)B2Y 12 Single-mode E9/125 ITU-T G.652 12 7,5 1500 150,0 1,60 300 40,0 802141
A-DQ(ZN)B2Y 24 Multimode G50/125 OM2 24 8,5 1500 170,0 1,90 300 60,0 800762
A-DQ(ZN)B2Y 24 Multimode G62.5/125 OM1 24 8,5 1500 170,0 1,90 300 60,0 802136
A-DQ(ZN)B2Y 24 Single-mode E9/125 ITU-T G.652 24 8,5 1500 170,0 1,90 300 60,0 802142

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM pact fibre-optic cables are characterized by a design that is particularly easy to mount and is rodent-protected. Around a central
grooved cable, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent protection, strain relief, and waterproofing
in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This construction
is particularly used in underground, tubes and channel areas, where normal tensile stresses and/or transverse compressions occur and rodent infestation
is to be expected.

621
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. DIN VDE 0888
A-DQ(ZN)B2Y, central

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Glass yarns Laying, max.: +50C Halogen-free acc. to 60754-2
Type of armouring: Glass yarns Operating, min.: -20C Longitudinally water-tight acc. to
Outer sheath material: PE Operating, max.: +60C IEC 60794-1-2-F5
Outer sheath colour: Black UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)B2Y 2 Multimode G50/125 OM2 2 10,0 2500 160,0 1,60 300 85,0 80196
A-DQ(ZN)B2Y 2 Multimode G62.5/125 OM1 2 10,0 2500 160,0 1,60 300 85,0 80212
A-DQ(ZN)B2Y 2 Single-mode E9/125 ITU-T G.652 2 10,0 2500 160,0 1,60 300 85,0 80180
A-DQ(ZN)B2Y 4 Multimode G50/125 OM2 4 10,0 2500 160,0 1,60 300 85,0 80197
A-DQ(ZN)B2Y 4 Multimode G62.5/125 OM1 4 10,0 2500 160,0 1,60 300 85,0 80213
A-DQ(ZN)B2Y 4 Single-mode E9/125 ITU-T G.652 4 10,0 2500 160,0 1,60 300 85,0 80181
A-DQ(ZN)B2Y 6 Multimode G50/125 OM2 6 10,0 2500 160,0 1,60 300 85,0 80198
A-DQ(ZN)B2Y 6 Multimode G62.5/125 OM1 6 10,0 2500 160,0 1,60 300 85,0 80214
A-DQ(ZN)B2Y 6 Single-mode E9/125 ITU-T G.652 6 10,0 2500 160,0 1,60 300 85,0 80182
A-DQ(ZN)B2Y 8 Multimode G50/125 OM2 8 10,0 2500 160,0 1,60 300 85,0 80199
A-DQ(ZN)B2Y 8 Multimode G62.5/125 OM1 8 10,0 2500 160,0 1,60 300 85,0 80215
A-DQ(ZN)B2Y 8 Single-mode E9/125 ITU-T G.652 8 10,0 2500 160,0 1,60 300 85,0 80183
A-DQ(ZN)B2Y 12 Multimode G50/125 OM2 12 10,0 2500 160,0 1,60 300 85,0 80201
A-DQ(ZN)B2Y 12 Multimode G62.5/125 OM1 12 10,0 2500 160,0 1,60 300 85,0 80217
A-DQ(ZN)B2Y 12 Single-mode E9/125 ITU-T G.652 12 10,0 2500 160,0 1,60 300 85,0 80185
A-DQ(ZN)B2Y 16 Multimode G50/125 OM2 16 10,0 2500 180,0 1,80 300 95,0 80202
A-DQ(ZN)B2Y 16 Multimode G62.5/125 OM1 16 10,0 2500 180,0 1,80 300 95,0 80218
A-DQ(ZN)B2Y 16 Single-mode E9/125 ITU-T G.652 16 10,0 2500 180,0 1,80 300 95,0 80186
A-DQ(ZN)B2Y 24 Multimode G50/125 OM2 24 10,0 2500 180,0 1,80 300 95,0 80204
A-DQ(ZN)B2Y 24 Multimode G62.5/125 OM1 24 10,0 2500 180,0 1,80 300 95,0 80220
A-DQ(ZN)B2Y 24 Single-mode E9/125 ITU-T G.652 24 10,0 2500 180,0 1,80 300 95,0 80187

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount and is rodent-protected. Around a central grooved
cable, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent protection, strain relief, and waterproofing in
longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This construction
is particularly used in underground, tubes and channel areas, where normal tensile stresses and/or transverse compressions occur and rodent infestation
is to be expected.

622
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. DIN VDE 0888
A-DQ(ZN)B2Y, stranded

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Strain relief elements: Glass yarns Operating, min.: -20C Longitudinally water-tight acc. to
Type of armouring: Glass yarns Operating, max.: +60C IEC 60794-1-2-F5
Outer sheath material: PE UV-resistant
Outer sheath colour: Black

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)B2Y 24 Multimode G50/125 OM2 12 10,5 2700 210,0 2,70 600 95,0 81382
A-DQ(ZN)B2Y 24 Multimode G62.5/125 OM1 12 10,5 2700 210,0 2,70 600 95,0 80219
A-DQ(ZN)B2Y 24 Single-mode E9/125 ITU-T G.652 12 10,5 2700 210,0 2,70 600 95,0 80188
A-DQ(ZN)B2Y 36 Multimode G50/125 OM2 12 10,5 2700 210,0 2,70 600 95,0 81108
A-DQ(ZN)B2Y 36 Multimode G62.5/125 OM1 12 10,5 2700 210,0 2,70 600 95,0 81109
A-DQ(ZN)B2Y 36 Single-mode E9/125 ITU-T G.652 12 10,5 2700 210,0 2,70 600 95,0 81110
A-DQ(ZN)B2Y 48 Multimode G50/125 OM2 12 10,5 2700 210,0 2,70 600 95,0 82648
A-DQ(ZN)B2Y 48 Multimode G62.5/125 OM1 12 10,5 2700 210,0 2,70 600 95,0 81112
A-DQ(ZN)B2Y 48 Single-mode E9/125 ITU-T G.652 12 10,5 2700 210,0 2,70 600 95,0 81113
A-DQ(ZN)B2Y 60 Multimode G50/125 OM2 12 10,5 2700 210,0 2,70 600 95,0 80207
A-DQ(ZN)B2Y 60 Multimode G62.5/125 OM1 12 10,5 2700 210,0 2,70 600 95,0 80223
A-DQ(ZN)B2Y 60 Single-mode E9/125 ITU-T G.652 12 10,5 2700 210,0 2,70 600 95,0 80191
A-DQ(ZN)B2Y 72 Multimode G50/125 OM2 12 11,0 2700 220,0 2,90 600 100,0 81133
A-DQ(ZN)B2Y 72 Multimode G62.5/125 OM1 12 11,0 2700 220,0 2,90 600 100,0 81134
A-DQ(ZN)B2Y 72 Single-mode E9/125 ITU-T G.652 12 11,0 2700 220,0 2,90 600 100,0 81120
A-DQ(ZN)B2Y 84 Multimode G50/125 OM2 12 12,0 3000 240,0 3,60 600 140,0 80208
A-DQ(ZN)B2Y 84 Multimode G62.5/125 OM1 12 12,0 3000 240,0 3,60 600 140,0 80224
A-DQ(ZN)B2Y 84 Single-mode E9/125 ITU-T G.652 12 12,0 3000 240,0 3,60 600 140,0 80192
A-DQ(ZN)B2Y 96 Multimode G50/125 OM2 12 12,0 3000 240,0 3,60 600 140,0 81135
A-DQ(ZN)B2Y 96 Multimode G62.5/125 OM1 12 12,0 3000 240,0 3,60 600 140,0 81136
A-DQ(ZN)B2Y 96 Single-mode E9/125 ITU-T G.652 12 12,0 3000 240,0 3,60 600 140,0 81121
A-DQ(ZN)B2Y 108 Multimode G50/125 OM2 12 13,5 3000 270,0 4,30 600 155,0 80209
A-DQ(ZN)B2Y 108 Multimode G62.5/125 OM1 12 13,5 3000 270,0 4,30 600 155,0 80225
A-DQ(ZN)B2Y 108 Single-mode E9/125 ITU-T G.652 12 13,5 3000 270,0 4,30 600 155,0 80193
A-DQ(ZN)B2Y 120 Multimode G50/125 OM2 12 13,5 3000 270,0 4,30 600 155,0 80210
A-DQ(ZN)B2Y 120 Multimode G62.5/125 OM1 12 13,5 3000 270,0 4,30 600 155,0 80226
A-DQ(ZN)B2Y 120 Single-mode E9/125 ITU-T G.652 12 13,5 3000 270,0 4,30 600 155,0 80194
A-DQ(ZN)B2Y 144 Multimode G50/125 OM2 12 14,5 3000 290,0 5,40 600 200,0 80211
A-DQ(ZN)B2Y 144 Multimode G62.5/125 OM1 12 14,5 3000 290,0 5,40 600 200,0 80227
A-DQ(ZN)B2Y 144 Single-mode E9/125 ITU-T G.652 12 14,5 3000 290,0 5,40 600 200,0 80195

Dimensions and specifications may be changed without prior notice.


R
Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount, extremely tension-resistant and rodent-proof.
Around a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent
protection, strain relief, and waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly
off is therefore unnecessary. This construction is particularly used in underground, tubes and channel areas, where above-average tensile stresses
and/or transverse compressions occur and rodent infestation is to be expected.

623
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. DIN VDE 0888 pact
A-DQ(ZN)B2Y fibre combi, stranded

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Longitudinally water-tight acc. to
Strain relief elements: Glass yarns Operating, min.: -20C IEC 60794-1-2-F5
Type of armouring: Glass yarns Operating, max.: +60C UV-resistant
Outer sheath material: PE
Outer sheath colour: Black

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)B2Y 24 Single- and multimode OM2 + ITU-T 12 9,5 2500 200,0 2,50 400 90,0 803037
G50/125 G.652
A-DQ(ZN)B2Y 24 Single- und Multimode OM3 + ITU-T 12 9,5 2500 200,0 2,50 400 90,0 803923
G50/125 OM3 G.652
A-DQ(ZN)B2Y 48 Single- and multimode OM2 + ITU-T 12 9,5 2500 200,0 2,50 400 90,0 803038
G50/125 G.652
A-DQ(ZN)B2Y 48 Single- und Multimode OM3 + ITU-T 12 9,5 2500 200,0 2,50 400 90,0 803924
G50/125 OM3 G.652

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM pact fibre-optic cables are characterized by a design that is particularly easy to mount, tension-resistant and rodent-proof. Around
a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent protection,
strain relief and waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore
unnecessary. This construction is particularly used in underground, tubes and channel areas, where packing density also plays a role.

624
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. DIN VDE 0888
A-DQ(ZN)B2Y fibre combi, stranded

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Strain relief elements: Glass yarns Operating, min.: -20C Longitudinally water-tight acc. to
Type of armouring: Glass yarns Operating, max.: +60C IEC 60794-1-2-F5
Outer sheath material: PE UV-resistant
Outer sheath colour: Black

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)B2Y 24 Single- and multimode OM2 + ITU-T 12 10,5 2700 200,0 2,70 600 95,0 81478
G50/125 G.652
A-DQ(ZN)B2Y 48 Single- and multimode OM2 + ITU-T 12 10,5 2700 200,0 2,70 600 95,0 801183
G50/125 G.652

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount, extremely tension-resistant and rodent-proof.
Around a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent
protection, strain relief and waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly
off is therefore unnecessary. This construction is particularly used in underground, tubes and channel areas, where above-average tensile stresses
and/or transverse compressions occur and rodent infestation is to be expected.

625
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. DIN VDE 0888
A-DF(ZN)2Y

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Strain relief elements: Aramide Operating, min.: -20C Longitudinally water-tight acc. to
Outer sheath material: PE Operating, max.: +60C IEC 60794-1-2-F5
Outer sheath colour: Black UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DF(ZN)2Y 2 Multimode G50/125 OM2 2 9,5 2500 95,0 4,20 400 85,0 80016
A-DF(ZN)2Y 2 Multimode G62.5/125 OM1 2 9,5 2500 95,0 4,20 400 85,0 80033
A-DF(ZN)2Y 2 Single-mode E9/125 ITU-T G.652 2 9,5 2500 95,0 4,20 400 85,0 80000
A-DF(ZN)2Y 4 Multimode G50/125 OM2 4 9,5 2500 95,0 4,20 400 85,0 80017
A-DF(ZN)2Y 4 Multimode G62.5/125 OM1 4 9,5 2500 95,0 4,20 400 85,0 80034
A-DF(ZN)2Y 4 Single-mode E9/125 ITU-T G.652 4 9,5 2500 95,0 4,20 400 85,0 80001
A-DF(ZN)2Y 8 Multimode G50/125 OM2 8 9,5 2500 95,0 4,20 400 85,0 80019
A-DF(ZN)2Y 8 Multimode G62.5/125 OM1 8 9,5 2500 95,0 4,20 400 85,0 80036
A-DF(ZN)2Y 8 Single-mode E9/125 ITU-T G.652 8 9,5 2500 95,0 4,20 400 85,0 80003
A-DF(ZN)2Y 12 Multimode G50/125 OM2 12 9,5 2500 95,0 4,20 400 85,0 80021
A-DF(ZN)2Y 12 Multimode G62.5/125 OM1 12 9,5 2500 95,0 4,20 400 85,0 80038
A-DF(ZN)2Y 12 Single-mode E9/125 ITU-T G.652 12 9,5 2500 95,0 4,20 400 85,0 80005
A-DF(ZN)2Y 24 Multimode G50/125 OM2 12 9,5 2700 95,0 4,00 400 85,0 80024
A-DF(ZN)2Y 24 Multimode G62.5/125 OM1 12 9,5 2700 95,0 4,00 400 85,0 80041
A-DF(ZN)2Y 24 Single-mode E9/125 ITU-T G.652 12 9,5 2700 95,0 4,00 400 85,0 80008
A-DF(ZN)2Y 36 Multimode G50/125 OM2 12 9,5 2700 95,0 4,00 400 85,0 80912
A-DF(ZN)2Y 36 Multimode G62.5/125 OM1 12 9,5 2700 95,0 4,00 400 85,0 80913
A-DF(ZN)2Y 36 Single-mode E9/125 ITU-T G.652 12 9,5 2700 95,0 4,00 400 85,0 80914
A-DF(ZN)2Y 48 Multimode G50/125 OM2 12 9,5 2700 95,0 4,00 400 85,0 80026
A-DF(ZN)2Y 48 Multimode G62.5/125 OM1 12 9,5 2700 95,0 4,00 400 85,0 80046
A-DF(ZN)2Y 48 Single-mode E9/125 ITU-T G.652 12 9,5 2700 95,0 4,00 400 85,0 80010
A-DF(ZN)2Y 60 Multimode G50/125 OM2 12 9,5 2700 95,0 4,00 400 85,0 80027
A-DF(ZN)2Y 60 Multimode G62.5/125 OM1 12 9,5 2700 95,0 4,00 400 85,0 80047
A-DF(ZN)2Y 60 Single-mode E9/125 ITU-T G.652 12 9,5 2700 95,0 4,00 400 85,0 80011
A-DF(ZN)2Y 72 Multimode G50/125 OM2 12 10,0 2700 100,0 3,80 400 90,0 80473
A-DF(ZN)2Y 72 Multimode G62.5/125 OM1 12 10,0 2700 100,0 3,80 400 90,0 80474
A-DF(ZN)2Y 72 Single-mode E9/125 ITU-T G.652 12 10,0 2700 100,0 3,80 400 90,0 80475
A-DF(ZN)2Y 84 Multimode G50/125 OM2 12 10,7 3000 107,0 4,30 400 120,0 80028
A-DF(ZN)2Y 84 Multimode G62.5/125 OM1 12 10,7 3000 107,0 4,30 400 120,0 80048
A-DF(ZN)2Y 84 Single-mode E9/125 ITU-T G.652 12 10,7 3000 107,0 4,30 400 120,0 80012
A-DF(ZN)2Y 96 Multimode G50/125 OM2 12 11,5 3000 115,0 5,00 400 135,0 80777
A-DF(ZN)2Y 96 Multimode G62.5/125 OM1 12 11,5 3000 115,0 5,00 400 135,0 80774
A-DF(ZN)2Y 96 Single-mode E9/125 ITU-T G.652 12 11,5 3000 115,0 5,00 400 135,0 80764
A-DF(ZN)2Y 144 Multimode G50/125 OM2 12 14,5 3000 145,0 7,70 400 175,0 80032
A-DF(ZN)2Y 144 Multimode G62.5/125 OM1 12 14,5 3000 145,0 7,70 400 175,0 80051
A-DF(ZN)2Y 144 Single-mode E9/125 ITU-T G.652 12 14,5 3000 145,0 7,70 400 175,0 80015

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal direction
by filling a jelly mass into the stranding cavities. Non-metallic tension elements ensure above average strain relief. This construction is particularly used
in the area of telecommunication and long distance, but also in regular channels and tubes.

626
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. DIN VDE 0888
A-DF(ZN)B2Y

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Strain relief elements: Aramide Operating, min.: -20C Longitudinally water-tight acc. to
Type of armouring: Glass yarns Operating, max.: +60C IEC 60794-1-2-F5
Outer sheath material: PE UV-resistant
Outer sheath colour: Black

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DF(ZN)B2Y 2 Multimode G50/125 OM2 2 10,5 2700 105,0 4,40 400 90,0 80100
A-DF(ZN)B2Y 2 Multimode G62.5/125 OM1 2 10,5 2700 105,0 4,40 400 90,0 80115
A-DF(ZN)B2Y 2 Single-mode E9/125 ITU-T G.652 2 10,5 2700 105,0 4,40 400 90,0 80084
A-DF(ZN)B2Y 4 Multimode G50/125 OM2 4 10,5 2700 105,0 4,40 400 90,0 80101
A-DF(ZN)B2Y 4 Multimode G62.5/125 OM1 4 10,5 2700 105,0 4,40 400 90,0 80116
A-DF(ZN)B2Y 4 Single-mode E9/125 ITU-T G.652 4 10,5 2700 105,0 4,40 400 90,0 80085
A-DF(ZN)B2Y 8 Multimode G50/125 OM2 8 10,5 2700 105,0 4,40 400 90,0 80031
A-DF(ZN)B2Y 8 Multimode G62.5/125 OM1 8 10,5 2700 105,0 4,40 400 90,0 80771
A-DF(ZN)B2Y 8 Single-mode E9/125 ITU-T G.652 8 10,5 2700 105,0 4,40 400 90,0 80087
A-DF(ZN)B2Y 12 Multimode G50/125 OM2 12 10,5 2700 105,0 4,40 400 90,0 80104
A-DF(ZN)B2Y 12 Multimode G62.5/125 OM1 12 10,5 2700 105,0 4,40 400 90,0 80120
A-DF(ZN)B2Y 12 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 4,40 400 90,0 80089
A-DF(ZN)B2Y 24 Multimode G50/125 OM2 12 10,5 2700 105,0 4,40 400 90,0 80759
A-DF(ZN)B2Y 24 Multimode G62.5/125 OM1 12 10,5 2700 105,0 4,40 400 90,0 80123
A-DF(ZN)B2Y 24 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 4,40 400 90,0 80092
A-DF(ZN)B2Y 36 Multimode G50/125 OM2 12 10,5 2700 105,0 4,30 400 90,0 81137
A-DF(ZN)B2Y 36 Multimode G62.5/125 OM1 12 10,5 2700 105,0 4,30 400 90,0 81138
A-DF(ZN)B2Y 36 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 4,30 400 90,0 81139
A-DF(ZN)B2Y 48 Multimode G50/125 OM2 12 10,5 2700 105,0 4,20 400 90,0 80109
A-DF(ZN)B2Y 48 Multimode G62.5/125 OM1 12 10,5 2700 105,0 4,20 400 90,0 80125
A-DF(ZN)B2Y 48 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 4,20 400 90,0 80094
A-DF(ZN)B2Y 60 Multimode G50/125 OM2 12 10,5 2700 105,0 4,20 400 90,0 80110
A-DF(ZN)B2Y 60 Multimode G62.5/125 OM1 12 10,5 2700 105,0 4,20 400 90,0 80126
A-DF(ZN)B2Y 60 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 4,20 400 90,0 80095
A-DF(ZN)B2Y 72 Multimode G50/125 OM2 12 11,0 2700 110,0 4,10 400 95,0 81143
A-DF(ZN)B2Y 72 Multimode G62.5/125 OM1 12 11,0 2700 110,0 4,10 400 95,0 81144
A-DF(ZN)B2Y 72 Single-mode E9/125 ITU-T G.652 12 11,0 2700 110,0 4,10 400 95,0 81145
A-DF(ZN)B2Y 84 Multimode G50/125 OM2 12 11,5 3000 115,0 4,60 400 136,0 80111
A-DF(ZN)B2Y 84 Multimode G62.5/125 OM1 12 11,5 3000 115,0 4,60 400 136,0 80127
A-DF(ZN)B2Y 84 Single-mode E9/125 ITU-T G.652 12 11,5 3000 115,0 4,60 400 136,0 80096
A-DF(ZN)B2Y 96
A-DF(ZN)B2Y 96
Multimode G50/125
Multimode G62.5/125
OM2
OM1
12
12
12,0
12,0
3000
3000
120,0
120,0
5,30
5,30
400
400
155,0
155,0
81147
81148
R
A-DF(ZN)B2Y 96 Single-mode E9/125 ITU-T G.652 12 12,0 3000 120,0 5,30 400 155,0 81149
A-DF(ZN)B2Y 144 Multimode G50/125 OM2 12 14,5 3000 145,0 8,00 400 228,0 80114
A-DF(ZN)B2Y 144 Multimode G62.5/125 OM1 12 14,5 3000 145,0 8,00 400 228,0 80130
A-DF(ZN)B2Y 144 Single-mode E9/125 ITU-T G.652 12 14,5 3000 145,0 8,00 400 228,0 80099

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal direction
by filling a jelly mass into the stranding cavities. Non-metallic tension elements and glass yarns ensure above average strain relief and rodent protection.
This construction is particularly used in the area of telecommunication and long distance, but also in regular channels and tubes where rodent infestation
is possible.

627
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. DIN VDE 0888
A-DF(ZN)2Y4Y

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Strain relief elements: Aramide Operating, min.: -20C Longitudinally water-tight acc. to
Inner sheath material: PE Operating, max.: +60C IEC 60794-1-2-F5
Type of armouring: PA sheath Cable, laterally water-tight
Outer sheath material: PA UV-resistant
Outer sheath colour: Black

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DF(ZN)2Y4Y 2 Multimode G50/125 OM2 2 10,0 2700 100,0 6,10 400 90,0 80915
A-DF(ZN)2Y4Y 2 Multimode G62.5/125 OM1 2 10,0 2700 100,0 6,10 400 90,0 80927
A-DF(ZN)2Y4Y 2 Single-mode E9/125 ITU-T G.652 2 10,0 2700 100,0 6,10 400 90,0 80945
A-DF(ZN)2Y4Y 4 Multimode G50/125 OM2 4 10,0 2700 100,0 6,10 400 90,0 80735
A-DF(ZN)2Y4Y 4 Multimode G62.5/125 OM1 4 10,0 2700 100,0 6,10 400 90,0 80928
A-DF(ZN)2Y4Y 4 Single-mode E9/125 ITU-T G.652 4 10,0 2700 100,0 6,10 400 90,0 80895
A-DF(ZN)2Y4Y 8 Multimode G50/125 OM2 8 10,0 2700 100,0 6,10 400 90,0 80691
A-DF(ZN)2Y4Y 8 Multimode G62.5/125 OM1 8 10,0 2700 100,0 6,10 400 90,0 80809
A-DF(ZN)2Y4Y 8 Single-mode E9/125 ITU-T G.652 8 10,0 2700 100,0 6,10 400 90,0 80118
A-DF(ZN)2Y4Y 12 Multimode G50/125 OM2 12 10,0 2700 100,0 6,10 400 90,0 80627
A-DF(ZN)2Y4Y 12 Multimode G62.5/125 OM1 12 10,0 2700 100,0 6,10 400 90,0 80931
A-DF(ZN)2Y4Y 12 Single-mode E9/125 ITU-T G.652 12 10,0 2700 100,0 6,10 400 90,0 80947
A-DF(ZN)2Y4Y 24 Multimode G50/125 OM2 12 10,0 2700 100,0 6,10 400 90,0 80578
A-DF(ZN)2Y4Y 24 Multimode G62.5/125 OM1 12 10,0 2700 100,0 6,10 400 90,0 80576
A-DF(ZN)2Y4Y 24 Single-mode E9/125 ITU-T G.652 12 10,0 2700 100,0 6,10 400 90,0 80577
A-DF(ZN)2Y4Y 36 Multimode G50/125 OM2 12 10,0 2700 100,0 6,00 400 90,0 80672
A-DF(ZN)2Y4Y 36 Multimode G62.5/125 OM1 12 10,0 2700 100,0 6,00 400 90,0 80935
A-DF(ZN)2Y4Y 36 Single-mode E9/125 ITU-T G.652 12 10,0 2700 100,0 6,00 400 90,0 80950
A-DF(ZN)2Y4Y 48 Multimode G50/125 OM2 12 10,0 2700 100,0 6,00 400 90,0 80732
A-DF(ZN)2Y4Y 48 Multimode G62.5/125 OM1 12 10,0 2700 100,0 6,00 400 90,0 80936
A-DF(ZN)2Y4Y 48 Single-mode E9/125 ITU-T G.652 12 10,0 2700 100,0 6,00 400 90,0 80951
A-DF(ZN)2Y4Y 60 Multimode G50/125 OM2 12 10,0 2700 100,0 5,80 400 90,0 80920
A-DF(ZN)2Y4Y 60 Multimode G62.5/125 OM1 12 10,0 2700 100,0 5,80 400 90,0 80938
A-DF(ZN)2Y4Y 72 Multimode G50/125 OM2 12 10,5 2700 105,0 5,80 400 95,0 80921
A-DF(ZN)2Y4Y 72 Multimode G62.5/125 OM1 12 10,5 2700 105,0 5,80 400 95,0 80939
A-DF(ZN)2Y4Y 72 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 5,80 400 95,0 80954
A-DF(ZN)2Y4Y 84 Multimode G50/125 OM2 12 11,0 3000 110,0 8,40 400 110,0 80922
A-DF(ZN)2Y4Y 84 Multimode G62.5/125 OM1 12 11,0 3000 110,0 8,40 400 110,0 80940
A-DF(ZN)2Y4Y 84 Single-mode E9/125 ITU-T G.652 12 11,0 3000 110,0 8,40 400 110,0 80955
A-DF(ZN)2Y4Y 96 Multimode G50/125 OM2 12 11,5 3000 115,0 7,20 400 120,0 80923
A-DF(ZN)2Y4Y 96 Multimode G62.5/125 OM1 12 11,5 3000 115,0 7,20 400 120,0 80941
A-DF(ZN)2Y4Y 96 Single-mode E9/125 ITU-T G.652 12 11,5 3000 115,0 7,20 400 120,0 80956
A-DF(ZN)2Y4Y 144 Multimode G50/125 OM2 12 14,5 3000 145,0 10,40 400 180,0 80926
A-DF(ZN)2Y4Y 144 Multimode G62.5/125 OM1 12 14,5 3000 145,0 10,40 400 180,0 80944
A-DF(ZN)2Y4Y 144 Single-mode E9/125 ITU-T G.652 12 14,5 3000 145,0 10,40 400 180,0 80959

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal direction
by filling a jelly mass into the stranding cavities. Non-metallic tension elements and a second outer sheath made of polyamide (PA) ensure above
average strain relief and rodent protection. This construction is particularly used in the area of telecommunication and long distance, but also in regular
channels and tubes where rodent infestation is possible.

628
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


Microduct
A-DQ2Y, central

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -20C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Aramide Laying, max.: +60C Halogen-free acc. to 60754-2
Outer sheath material: PE Operating, min.: -20C Longitudinally water-tight acc. to
Outer sheath colour: Black Operating, max.: +60C IEC 60794-1-2-F5
UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ2Y 4 Single-mode E9/125 ITU-T G.652 4 2,5 180 40,0 1,40 100 6,0 803664
central
A-DQ2Y 12 Single-mode E9/125 ITU-T G.652 12 2,5 180 40,0 1,40 100 6,0 803929
central

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM micro fibre-optic cables are characterized by a design that is slim but robust. Around a central tube, there is a composite of swelling
fleece with characteristics that ensure the strain relief, and waterproofing in longitudinal direction of the cable. This construction is particularly used
in tubes and channels. These cables can be blowing into microducts.

629
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


Microduct
A-DQ2Y, stranded

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Aramide Laying, max.: +50C Halogen-free acc. to 60754-2
Outer sheath material: PE Operating, min.: -25C Longitudinally water-tight acc. to
Outer sheath colour: Black Operating, max.: +70C IEC 60794-1-2-F5
UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ2Y 4 Single-mode E9/125 ITU-T G.652 4 5,8 850 70,0 0,89 150 27,0 803931
stranded
A-DQ2Y 12 Single-mode E9/125 ITU-T G.652 12 5,8 850 70,0 0,87 150 27,0 803932
stranded
A-DQ2Y 24 Single-mode E9/125 ITU-T G.652 12 5,8 850 70,0 0,87 150 27,0 803930
stranded
A-DQ2Y 48 Single-mode E9/125 ITU-T G.652 12 5,8 850 70,0 0,87 150 27,0 803658
stranded
A-DQ2Y 72 Single-mode E9/125 ITU-T G.652 12 5,8 850 60,0 0,87 150 27,0 803659
stranded
A-DQ2Y 96 Single-mode E9/125 ITU-T G.652 12 6,8 1000 70,0 1,25 150 40,0 803660
stranded
A-DQ2Y 144 Single-mode E9/125 ITU-T G.652 12 9,4 1800 140,0 2,19 150 79,0 803661
stranded
A-DQ2Y 288 Single-mode E9/125 ITU-T G.652 12 11,2 1500 115,0 2,97 100 90,0 803668
stranded

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM micro fibre-optic cables are characterized by a design that is slim but robust. Around stranded tubes, there is a composite of swelling
fleece with characteristics that ensure the strain relief, and waterproofing in longitudinal direction of the cable. This construction is particularly used
in tubes and channels. These cables can be blowing into microducts.

630
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


steel armoured
A-DQ(ZN)(SR)2Y

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Glass yarns Laying, max.: +50C Halogen-free acc. to 60754-2
Type of armouring: Steel rib Operating, min.: -20C Longitudinally water-tight acc. to
Outer sheath material: PE Operating, max.: +70C IEC 60794-1-2-F5
Outer sheath colour: Black Cable, laterally water-tight
UV-resistant

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)(SR)2Y 4 Multimode G50/125 OM2 4 9,5 1500 95,0 2,00 500 115,0 802917
A-DQ(ZN)(SR)2Y 4 Multimode G62.5/125 OM1 4 9,5 1500 95,0 2,00 500 115,0 803925
A-DQ(ZN)(SR)2Y 4 Single-mode E9/125 ITU-T G.652 4 9,5 1500 95,0 2,00 500 105,0 803927
A-DQ(ZN)(SR)2Y 12 Multimode G50/125 OM2 12 9,5 1500 95,0 2,00 500 115,0 802918
A-DQ(ZN)(SR)2Y 12 Multimode G62.5/125 OM1 12 9,5 1500 95,0 2,00 500 115,0 803926
A-DQ(ZN)(SR)2Y 12 Single-mode E9/125 ITU-T G.652 12 9,5 1500 95,0 2,00 500 115,0 803928

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a compact construction with a swelling fleece. Above-average rodent protection is achieved
with the metallic rodent protection (steel groove) and an outer sheath made of PE. This construction is particularly used in the area of telecommunication
and long distance, but also in regular channels and tubes where rodent infestation is possible.

631
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable


acc. ARCOR Standard
A-DF(ZN)2Y(SR)2Y

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Strain relief elements: Aramide Operating, min.: -25C Longitudinally water-tight acc. to
Inner sheath material: PE Operating, max.: +60C IEC 60794-1-2-F5
Type of armouring: Steel rib Cable, laterally water-tight
Outer sheath material: PE UV-resistant
Outer sheath colour: Black

Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DF(ZN)2Y(SR)2Y 12 Single-mode E9/125 ITU-T G.652 2 13,0 2700 130,0 0,00 800 180,0 82190
A-DF(ZN)2Y(SR)2Y 24 Single-mode E9/125 ITU-T G.652 4 13,0 2700 130,0 0,00 800 180,0 800708
A-DF(ZN)2Y(SR)2Y 48 Single-mode E9/125 ITU-T G.652 12 13,0 2700 130,0 0,00 800 180,0 800709
A-DF(ZN)2Y(SR)2Y 60 Single-mode E9/125 ITU-T G.652 12 13,0 2700 130,0 0,00 800 180,0 800710

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal direction
by filling a jelly mass into the stranding cavities. Above-average rodent protection is achieved with the metallic rodent protection (steel groove) and
the second outer sheath made of PE. This construction is particularly used in the area of telecommunication and long distance where ARCOR standards
must be followed, but also in regular channels and tubes where rodent infestation is possible.

632
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Outdoor Cable Hybrid


acc. DIN VDE 0888
A-DSQ(ZN)B2Y

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -10C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +60C Longitudinally water-tight acc. to
Number of fibres per core: 4 Operating, min.: -25C IEC 60794-1-2-F5
Strain relief elements: Glass yarns Operating, max.: +60C UV-resistant
Type of armouring: Glass yarns
Outer sheath material: PE
Outer sheath colour: Black

Designation No. of Fibre type No. of Dimensions Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres copper of copper app. mm tensile bending app. MJ / m transverse kg / km
cores cores force N radius pressure
mm mm N / cm
A-DSQ(ZN)B2Y 4 Multimode G50/125 2 1,2 12,0 2100 300 4,80 200 140,0 81209
A-DSQ(ZN)B2Y 4 Multimode G62.5/125 2 1,2 12,0 2100 300 4,80 200 140,0 81255
A-DSQ(ZN)B2Y 4 Single-mode E9/125 2 1,2 12,0 2100 300 4,80 200 140,0 81256
A-DSQ(ZN)B2Y 4 Multimode G50/125 2 1,5 12,5 2300 320 4,80 200 160,0 82561
A-DSQ(ZN)B2Y 4 Multimode G62.5/125 2 1,5 12,5 2300 320 4,80 200 160,0 81257
A-DSQ(ZN)B2Y 4 Single-mode E9/125 2 1,5 12,5 2300 320 4,80 200 160,0 81258
A-DSQ(ZN)B2Y 4 Multimode G50/125 4 1,5 17,0 2600 430 5,80 200 250,0 82786
A-DSQ(ZN)B2Y 4 Multimode G62.5/125 4 1,5 17,0 2600 430 5,80 200 250,0 81259
A-DSQ(ZN)B2Y 4 Single-mode E9/125 4 1,5 17,0 2600 430 5,80 200 250,0 81260

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are designed especially for use in fibre-optical temperature measurements, such as monitoring of dams. The
extreme mechanical requirements in these areas are fulfilled by the specially designed cable construction. These lines are hybrid glass fibre lines with
copper cores and a special PE outer sheath.

633
Data, Network and Bus Technology / HELUKAT Copper data cables

Fibre Optic Outdoor Cable Hybrid


acc. DIN VDE 0888
A-DSF(L)(ZN)2Y

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Number of fibres per core: 12 Operating, min.: -25C Longitudinally water-tight acc. to
Strain relief elements: Aramide Operating, max.: +60C IEC 60794-1-2-F5
Aluminium laminated sheath Cable, laterally water-tight
Outer sheath material: PE UV-resistant
Outer sheath colour: Black

Designation No. of Fibre type No. of Dimensions Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres copper of copper app. mm tensile bending app. MJ / m transverse kg / km
cores cores force N radius pressure
mm mm N / cm
A-DSF(L)(ZN)2Y 12 Single-mode E9/125 2 0,6 12,0 2500 200 4,80 250 135,0 80495
A-DSF(L)(ZN)2Y 12 Single-mode E9/125 4 0,6 12,0 2500 200 4,80 250 140,0 80497
A-DSF(L)(ZN)2Y 24 Single-mode E9/125 2 0,6 13,1 2500 200 4,80 250 139,0 800753
A-DSF(L)(ZN)2Y 24 Single-mode E9/125 4 0,6 13,1 2500 200 4,80 250 144,0 801182
A-DSF(L)(ZN)2Y 48 Single-mode E9/125 2 0,6 13,1 2500 200 4,80 250 141,0 80501
A-DSF(L)(ZN)2Y 48 Single-mode E9/125 4 0,6 13,1 2500 200 4,80 250 146,0 80503
A-DSF(L)(ZN)2Y 60 Single-mode E9/125 2 0,6 14,1 2500 230 4,80 250 166,0 80504
A-DSF(L)(ZN)2Y 60 Single-mode E9/125 4 0,6 14,1 2500 230 4,80 250 171,0 80506
A-DSF(L)(ZN)2Y 72 Single-mode E9/125 2 0,6 14,8 2500 240 5,10 250 179,0 80507
A-DSF(L)(ZN)2Y 72 Single-mode E9/125 4 0,6 14,8 2500 240 5,10 250 184,0 80509
A-DSF(L)(ZN)2Y 96 Single-mode E9/125 2 0,6 16,6 3000 280 6,30 250 276,0 80510
A-DSF(L)(ZN)2Y 96 Single-mode E9/125 4 0,6 16,6 3000 280 6,30 250 281,0 80512
A-DSF(L)(ZN)2Y 120 Single-mode E9/125 2 0,6 18,4 3000 290 8,50 250 280,0 80513
A-DSF(L)(ZN)2Y 120 Single-mode E9/125 4 0,6 18,4 3000 290 8,50 250 285,0 80515
A-DSF(L)(ZN)2Y 144 Single-mode E9/125 2 0,6 20,3 3500 310 10,00 250 331,0 80516
A-DSF(L)(ZN)2Y 144 Single-mode E9/125 4 0,6 20,3 3500 310 10,00 250 336,0 80518

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM outdoor cables are designed for use under extreme environmental conditions. With the double jelly filling and the Al/PE laminated
sheath, they are water proof in longitudinal and transverse direction. The welded Al tape acts as an additional vapour barrier. These cables can be
layed directly in the ground, in tubes and in ducts. They are mainly used in local and long-distance networks.

634
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Aerial Fibre Optic Cable


metall free
ADSS

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -10C Sag at 25C ADSS 9: 2,0 m
GRP support element Laying, max.: +60C Sag at 25C ADSS 16: 4,5 m
Strain relief elements: Aramide Operating, min.: -25C Sag at 25C ADSS 35: 9,5 m
Inner sheath material: PE Operating, max.: +70C Halogen-free acc. to 60754-2
Outer sheath material: PE Longitudinally water-tight acc. to
Outer sheath colour: Black IEC 60794-1-2-F5
Cable, laterally water-tight
UV-resistant

Designation Number of Fibre type Number of Span width Max. Additional Min. stat. Outer Weight Part no.
fibres fibres per m tensile load bending app. mm kg / km
core force kN daN / m radius
mm
ADSS 9 12 Single-mode E9/125 4 150 9 0,5 410 13,6 135 82390
ADSS 9 24 Single-mode E9/125 4 150 9 0,5 410 13,6 137 82391
ADSS 9 36 Single-mode E9/125 6 150 9 0,5 470 15,6 177 82392
ADSS 9 48 Single-mode E9/125 8 150 9 0,5 470 15,6 178 82393
ADSS 9 60 Single-mode E9/125 12 150 9 0,5 450 15,0 161 82394
ADSS 9 144 Single-mode E9/125 12 150 9 0,5 630 20,8 316 82395

ADSS 16 12 Single-mode E9/125 4 350 16 0,3 430 14,4 162 82396


ADSS 16 24 Single-mode E9/125 4 350 16 0,3 430 14,4 165 82397
ADSS 16 36 Single-mode E9/125 6 350 16 0,3 500 16,4 200 82398
ADSS 16 48 Single-mode E9/125 8 350 16 0,3 500 16,4 201 82399
ADSS 16 60 Single-mode E9/125 12 350 16 0,3 480 15,8 184 82400
ADSS 16 144 Single-mode E9/125 12 350 16 0,3 650 21,6 333 82401

ADSS 35 12 Single-mode E9/125 4 700 35 0,35 520 17,2 198 82402


ADSS 35 24 Single-mode E9/125 4 700 35 0,35 520 17,2 200 82403
ADSS 35 36 Single-mode E9/125 6 700 35 0,35 580 19,2 240 82404
ADSS 35 48 Single-mode E9/125 8 700 35 0,35 580 19,2 241 82405
ADSS 35 60 Single-mode E9/125 12 700 35 0,35 560 18,6 227 82406
ADSS 35 144 Single-mode E9/125 12 700 35 0,35 730 24,4 381 82407

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM outdoor cables designed as aerial cables for freely suspended installations on posts and masts. The construction is waterproof in
longitudinal direction thanks to the use of jelly-filled bundle cores and swelling tape. The outer jacket is UV-resistant and at the same time provides
protection against environmental influences, such as snow, ice, sun insolation and wind.

635
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Cable flexible


WK - mobile WK
A-V(ZN)11Y

Cable structure Temperature range Other data


Core type: Tight buffer Laying, min.: +5C Max. tensile force: 650 N
Strain relief elements: Aramide Laying, max.: +50C Max. transverse pressure: 40 N / cm
Outer sheath colour: Orange Operating, min.: -30C Longitudinally water-tight acc. to
Operating, max.: +70C IEC 60794-1-2-F5
UV-resistant
Resistant to hammer impact acc. to
IEC 60794-1-2-E6
Bending cycles acc. to IEC 60794-1-2-E6:
500.000
Oil-resistant

Designation Number of Fibre type Outer Outer Min. stat. Flame halogen- UL Weight Part no.
fibres app. mm sheath bending proof free kg / km
material radius
mm
Fibre-optic cable 2 Multimode G50/125 5,0 PUR 75 yes yes no 20 80382
Fibre-optic cable 2 Multimode G62.5/125 5,0 PUR 75 yes yes no 20 80363
Fibre-optic cable 4 Multimode G50/125 5,8 PUR 90 yes yes no 31 80534
Fibre-optic cable 4 Multimode G62.5/125 5,8 PUR 90 yes yes no 31 81036
Fibre-optic cable 4 Single-mode E9/125 5,8 PUR 90 yes yes no 31 801727
Fibre-optic cable 8 Multimode G50/125 7,0 PUR 105 yes yes no 47 81037
Fibre-optic cable 8 Multimode G62.5/125 7,0 PUR 105 yes yes no 47 81038

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM cables were designed as mobile field cables. They are easily wound up on a drum and are very tension-proof. As the outer sheath
is tightly anchored on the aramid braiding, it is especially suitable for mobile use. The advantage of these cables is evident especially where mobile
fibre-optic lines are to be installed, such as for drag chains, TV transmission, supervision of protected areas, etc.

636
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Cable flexible


WK - UL/CSA WK
A-V(ZN)YY

Cable structure Temperature range Other data


Core type: Tight buffer Laying, min.: 0C Max. tensile force: 1200 N
Strain relief elements: Aramide Laying, max.: +50C Max. transverse pressure: 44 N / cm
Outer sheath colour: Orange Operating, min.: -30C Longitudinally water-tight acc. to
Operating, max.: +80C IEC 60794-1-2-F5
UV-resistant
Bending cycles acc. to IEC 60794-1-2-E6: 9.000
Oil-resistant

Designation Number of Fibre type Outer Outer Inner Min. stat. Flame halogen- UL Weight Part no.
fibres app. mm sheath sheath bending proof free kg / km
material material radius
mm
Fibre-optic cable 4 Multimode G50/125 7,0 PVC PVC 75 yes no yes 50 802792
Fibre-optic cable 4 Multimode G62.5/125 7,0 PVC PVC 75 yes no yes 50 803934
Fibre-optic cable 4 Single-mode E9/125 7,0 PVC PVC 75 yes no yes 50 803935

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM cables were designed as mobile field cables. They are easily wound up on a drum and are very tension-proof. As the outer sheath
is tightly anchored on the aramid braiding, it is especially suitable for mobile use. The advantage of these cables is evident especially where mobile
fibre-optic lines are to be installed, such as windturbine projects, TV transmission, supervision of protected areas, etc.. This series with PVC jacket is
certified according the UL/CSA standard OFNG/ FT4.

637
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Cable flexible


WK robust PUR + PVC (UL/CSA) WK
AT-V(ZN)H(ZN)11Y, AT-V(ZN)Y(ZN)Y

Cable structure Temperature range Other data


Core type: Composite buffered Laying, min.: -10C Max. tensile force: 4800 N
Strain relief elements: Aramide Laying, max.: +50C Max. transverse pressure: 200 N / cm
Outer sheath colour: Black Operating, min.: -40C Longitudinally water-tight acc. to
Operating, max.: +90C IEC 60794-1-2-F5
UV-resistant
Resistant to hammer impact acc. to
IEC 60794-1-2-E6
Bending cycles acc. to IEC 60794-1-2-E6: 9.000
Oil-resistant

Designation Number of Fibre type Outer Outer Inner Min. stat. Flame halogen- UL Weight Part no.
fibres app. mm sheath sheath bending proof free kg / km
material material radius
mm
AT-V(ZN)H(ZN)11Y 4 Multimode G50/125 8,5 PUR ULSZH 100 yes yes no 125 803346
AT-V(ZN)Y(ZN)Y 4 Multimode G50/125 8,5 PVC PVC 130 yes no yes 125 803348
AT-V(ZN)Y(ZN)Y 12 Multimode G50/125 12,4 PVC PVC 190 yes no yes 320 803349
AT-V(ZN)H(ZN)11Y 12 Multimode G50/125 12,4 PUR ULSZH 190 yes yes no 320 803347
AT-V(ZN)H(ZN)11Y 12 Single-mode E9/125 12,4 PUR ULSZH 190 yes yes no 320 804700

Dimensions and specifications may be changed without prior notice.

Application
The HELUCOM WK range is set apart by its extreme rugged yet highly-flexible design. It is used wherever demanding environmental conditions and
extreme movements occur. The tight buffer structure enables the cable to be pre-assembled on site with ease. Applications are for example Windturbines,
TV transmissions, mobile field applications, etc..

638
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Cable flexible WK


AT-V(ZN)YY

Cable structure Temperature range Other data


Core type: Composite buffered Laying, min.: -10C Max. tensile force: 1200 N
Strain relief elements: Aramide Laying, max.: +50C Max. transverse pressure: 100 N / cm
Outer sheath colour: Yellow Operating, min.: -40C UV-resistant
Operating, max.: +90C Resistant to hammer impact acc. to
IEC 60794-1-2-E6
Bending cycles acc. to IEC 60794-1-2-E6: 15
Oil-resistant

Designation Number of Fibre type Outer Outer Inner Min. stat. Flame halogen- UL Weight Part no.
fibres app. mm sheath sheath bending proof free kg / km
material material radius
mm
Fibre-optic cable 4 Multimode G50/125 7,4 PVC PVC 90 yes no no 65 803364

Dimensions and specifications may be changed without prior notice.

Application
The HELUCOM range is set apart by its extreme rugged yet flexible design. It is used wherever demanding environmental conditions and movements
occur. The tight buffer structure enables the cable to be pre-assembled on site with ease. Applications are for example industry applications, TV
transmissions, etc..

639
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Breakout Cable


outdoor
AT-V(ZN)HH(ZN)B2Y

Cable structure Temperature range Other data


Core type: Composite buffered Laying, min.: -5C Longitudinally water-tight acc. to
GRP support element Laying, max.: +50C IEC 60794-1-2-F5
Strain relief elements: Aramide Operating, min.: -20C UV-resistant
Inner sheath material: ULSZH Operating, max.: +60C Oil-resistant
Outer sheath material: PE
Outer sheath colour: Black

Designation Number of Fibre type Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres app. mm tensile bending transverse app. MJ / m kg / km
force N radius pressure
mm N / cm
AT-V(ZN)HH(ZN)B2Y 4 Multimode G50/125 13,5 1200 340 300 2,95 140 801352

Dimensions and specifications may be changed without prior notice.

Application
The HELUCOM range is set apart by its extreme rugged roden protected design. It is used wherever demanding environmental conditions while fixed
installations occur. The tight buffer structure enables the cable to be pre-assembled on site with ease. Applications are for example industry applications,
etc..

640
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Cable robust


multimode
AT-VYY

Cable structure Temperature range Other data


Core type: Tight buffer Laying, min.: -5C Flame-resistance acc. to IEC 60332-1
Strain relief elements: Aramide Laying, max.: +50C Longitudinally water-tight acc. to
Outer sheath material: PVC Operating, min.: -20C IEC 60794-1-2-F5
Outer sheath colour: Black Operating, max.: +60C UV-resistant
Oil-resistant

Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
AT-VYY 2 Multimode G62.5/125 1 6,8 x 10,2 400 110,0 300 1,10 76,0 800126

Dimensions and specifications may be changed without prior notice.

Application
This HELUCOM fibre-optic cable is suited for fixed installations in pits and channels, but also for flexible applications as jumper cable. Because of the
robust construction with Single- and Overall-jacket you also can use it in industrial areas. With the core-construction, direct plug manufacturing, even
on site, poses no problems.

641
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Cable flexible


HCS
I-VH, I-VHH

Cable structure Temperature range Other data


Core type: Composite buffered Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Aramide Laying, max.: +50C Halogen-free acc. to 60754-2
Outer sheath material: FRNC Operating, min.: -10C Flame-resistance acc. to IEC 60332-1
Outer sheath colour: Orange Operating, max.: +60C Smoke density acc. to IEC 61034

Designation Number of Fibre type Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres app. mm tensile bending radius transverse app. MJ / m kg / km
force N mm pressure
N / cm
I-VH 1 HCS 200/230 2,8 300 40 10 0,26 2,8 800579
I-VHH 2 HCS 200/230 3,8 x 6,6 600 50 10 0,52 30,0 81238

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM HCS fibre lines are suitable for stationary installation indoors. For heavy-duty mechanical requirements, such as application in
industrial environments, a version with PUR outer sheath is available on request. With a HCS fibre transmission lengths of up to 300m can be achieved.
With the tight buffer construction, direct plug manufacturing, even on site, poses no problems.

642
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Breakout Cable flexible


HCS
AT-V(ZN)HH

Cable structure Temperature range Other data


Core type: Composite buffered Laying, min.: -20C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Strain relief elements: Aramide Operating, min.: -20C Flame-resistance acc. to IEC 60332-1
Outer sheath material: FRNC Operating, max.: +70C Smoke density acc. to IEC 61034
Outer sheath colour: Black UV-resistant
Oil-resistant

Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
AT-V(ZN)HH 4 HCS 200/230 1 9,0 800 225,0 100 1,60 76,0 802260

Dimensions and specifications may be changed without prior notice.

Application
This HELUCOM HCS fibre cable is suitable for fixed and normal flexible installation. Possible applications are normal requirements and also limited
industrial environments. With the tight buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission
lengths of up to 300m can be achieved.

643
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Breakout Cable robust,


flexible
HCS UL/CSA
I-V(ZN)YY

Cable structure Temperature range Other data


Core type: Composite buffered Laying, min.: -20C Flame-resistance acc. to IEC 60332-1 and
Strain relief elements: Aramide Laying, max.: +75C IEC 60332-3
Outer sheath material: PVC Operating, min.: -30C UV-resistant
Outer sheath colour: Black Operating, max.: +85C Oil-resistant

Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
I-V(ZN)YY 2 HCS 200/230 1 7,5 800 100,0 300 1,40 68,0 801733

Dimensions and specifications may be changed without prior notice.

Application
This HELUCOM HCS fibre cable is suitable for fixed and normal flexible installations. Possible applications are normal and heavy-duty mechanical
requirements for example in industrial environments. Because of a special PVC jacket this construction is certified by UL (FT1 and FT4). With the tight
buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission lengths of up to 300m can be achieved.

644
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Breakout Cable robust,


flexible
HCS
I-V(ZN)Y11Y

Cable structure Temperature range Other data


Core type: Composite buffered Laying, min.: -5C Oil-resistant
Strain relief elements: Aramide Laying, max.: +50C
Outer sheath material: PUR Operating, min.: -20C
Outer sheath colour: Red Operating, max.: +70C

Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
I-V(ZN)Y11Y 2 HCS 200/230 1 7,0 800 50,0 150 1,014 43,0 800980

Dimensions and specifications may be changed without prior notice.

Application
This HELUCOM HCS fibre cable is suitable for fixed installation. Possible applications are normal and heavy-duty mechanical requirements for example
in industrial environments. With the tight buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission
lengths of up to 300m can be achieved.

645
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Breakout Cable robust


HCS
AT-VQH(ZN)B2Y

Cable structure Temperature range Other data


Core type: Composite buffered Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
GRP support element Laying, max.: +50C Halogen-free acc. to 60754-2
Strain relief elements: Aramide Operating, min.: -25C Longitudinally water-tight acc. to
Type of armouring: Glass yarns Operating, max.: +70C IEC 60794-1-2-F5
Outer sheath material: PE UV-resistant
Outer sheath colour: Black Oil-resistant

Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
AT-VQH(ZN)B2Y 2 HCS 200/230 1 11,0 1500 200,0 500 2,10 90,0 801196

Dimensions and specifications may be changed without prior notice.

Application
This HELUCOM HCS fibre cable is suitable for fixed installation outdoors. Possible applications are normal and heavy-duty mechanical requirements
for example in industrial environments. This is the reason we also equiped the cable with a non-metallic rodent-protection.With the tight buffer
construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission lengths of up to 300m can be achieved.

646
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Fibre Optic Universal Cable


HCS
A/I-DQ(ZN)BH

Cable structure Temperature range Other data


Core type: Loose tube Laying, min.: -5C Corrosiveness acc. to EN50267-2-3
Strain relief elements: Glass yarns Laying, max.: +50C Halogen-free acc. to 60754-2
Type of armouring: Glass yarns Operating, min.: -20C Flame-resistance acc. to IEC 60332-1
Outer sheath material: FR/LSOH Operating, max.: +70C Smoke density acc. to IEC 61034
Outer sheath colour: Black Longitudinally water-tight acc. to
IEC 60794-1-2-F5
UV-resistant

Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 4 HCS 200/230 4 8,5 1500 130,0 150 2,00 76,0 801198
A/I-DQ(ZN)BH 8 HCS 200/230 8 8,5 1500 130,0 150 2,00 79,0 802001
A/I-DQ(ZN)BH 12 HCS 200/230 12 8,5 1500 130,0 150 2,00 82,0 802002
A/I-DQ(ZN)BH 24 HCS 200/230 8 17,7 6000 265,0 300 3,20 280,0 802003
A/I-DQ(ZN)BH 48 HCS 200/230 8 18,9 6000 285,0 300 3,20 355,0 802004

Dimensions and specifications may be changed without prior notice.

Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for fixed indoor and
outdoor cabling of buildings and industry facilities. They are used in particular if the installation is to be done in one piece from the inside to the outside
without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are perfectly suited for
outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.

647
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Plastic Fibre cable industry


POF/PE
I-V2Y, I-V2Y(ZN)11Y

Cable structure Optical characteristic Temperature range


Fibre type: POF 980/1000 Refractive index core: 1,492 Laying, min.: -20C
Fibre cladding: PE Refractive index cladding: 1,419 Laying, max.: +80C
Numerical aperture: 0,5 Operating, min.: -20C
Attenuation see table Operating, max.: +80C

Designation Outer Sheath Outer Max. Min. stat. Fibre Oil- Acc. to Weight Part no.
sheath colour app. mm tensile bending attenuation resistant DESINA kg / km
material force N radius
mm
I-V2Y 1P 980/1000 PE Black 2,2 70 25,0 160A1 no no 4,0 80532
I-V2Y 2P 980/1000 PE Black 2,2 x 4,4 140 25,0 160A1 no no 8,0 80388
I-V2Y(ZN)11Y 1P 980/1000 PUR Violet 5,8 400 30,0 230A1 yes yes 30,0 81611
I-V2Y(ZN)11Y 2P 980/1000 PUR Violet 6,0 400 31,0 230A1 yes yes 36,0 80629
I-V2Y(ZN)11Y 2P 980/1000 PUR Violet 6,0 400 31,0 230A1 yes yes 36,0 81882
I-V2Y(ZN)11Y 4P 980/1000 PUR Violet 7,1 400 45,0 230A1 yes yes 65,0 80630
I-V2Y(ZN)11Y 2P 980/1000 + 2x1mm Cu PUR Red 7,8 200 70,0 230A1 yes no 60,0 82032
I-V2Y(ZN)11Y 2P 980/1000 + 3x1,5mm Cu PUR Red 11,0 200 70,0 230A1 yes no 132,0 82033

Dimensions and specifications may be changed without prior notice.

Application
HELUCOM plastic-fibre cables are used in mechanical engineering, both in mobile and fixed applications. With different constructions, such as PUR
outer sheaths, special strain relief components, hybrid construction with copper cores for power supply or only raw fibre cables, any possible fields
of application are covered. Due to their solidity and their simple adjustability on site, the plastic-fibres (PMMA) are particularly suitable for applications
where trouble-free data transmission in necessary under heavy-duty conditions.

648
Data, Network and Bus Technology / HELUCOM Fibre Optic cables

Plastic Fibre Cable Industry


POF/PA
I-V4Y(ZN)11Y

Cable structure Optical characteristic Temperature range


Fibre type: POF 980/1000 Refractive index core: 1,492 Laying, min.: -5C
Fibre cladding: PA Refractive index cladding: 1,419 Laying, max.: +50C
Numerical aperture: 0,5 Operating, min.: -20C
Attenuation see table Operating, max.: +70C

Designation Outer Sheath Outer Max. Min. stat. Fibre Oil- Acc. to Weight Part no.
sheath colour app. mm tensile bending attenuation resistant DESINA kg / km
material force N radius
mm
I-V4Y(ZN)11Y 2P980/1000 RUGGED PUR Red 8,0 100 50,0 160A1 yes no 42,0 801200
I-V4Y(ZN)11Y 2P980/1000 FLEX RUGGED PUR Red 8,0 100 50,0 250A1 yes no 51,0 801201
I-V4Y(ZN)11Y 2P980/1000 HEAVY PUR Red 6,0 100 30,0 160A1 yes no 28,0 801202

Dimensions and specifications may be changed without prior notice.

Application
Signal lines as plastic optical fibre. The use of these transmission systems significantly reduces the number of different cables in a planned bus installation
in machine tools operations. Furthermore, possible EMC problems are prevented by the metal-free construction. The main application of these cables
are in machine construction and automobile industry (PA version).

649
FIBRESPECIFICATIONS
Granded index fibres (multimode)
Specification Fibre type G 50/125 Fibre type G 62,5/125
Fibre catergorie OM2 Standardfibre OM1 Standardfibre
Core diameter 50 + 3 m 62,5 + 3 m
Numerical aperture 0,200 + 0,015 0,275 + 0,015
Typ. attenuation 850 nm 2,8 dB/km 3,0 dB/km
1300 nm 0,7 dB/km 1,0 dB/km
Min. bandwidth 850 nm 500 MHz x km 200 MHz x km
1300 nm 800 MHz x km 500 MHz x km
Cladding diameter 125 + 1 m
Primary coating diameter 245 + 10 m
Core noncircularity <5%
Cladding concentricity error < 3,0 m
Cladding noncircularity < 2,0 %

Specification Fibre type G 50/125


Fibre catergorie OM3 Standardfibre OM4 Standardfibre
Core diameter 50 + 3 m 50 + 3 m
Numerical aperture 0,200 + 0,015 0,200 + 0,015
Typ. attenuation 850 nm 2,5 dB/km 3,0 dB/km
1300 nm 0,5 dB/km 1,0 dB/km
Min. bandwidth 850 nm 1500 MHz x km 3500 MHz x km
1300 nm 500 MHz x km 500 MHz x km
Cladding diameter 125 + 1 m 125 + 1 m
Primary coating diameter 245 + 10 m 245 + 10 m
Core noncircularity <5% <5%
Cladding concentricity error < 3,0 m < 6,0 m
Cladding noncircularity < 2,0 % < 2,0 %

Single-Mode-Fibre
Specification Fibre type E9...10/125 (single mode)
Fibre catergorie ITU-T G. 652.d
Attenuation 1300 nm 0,36 dB/km
1550 nm 0,22 dB/km
Dispersion 1285 - 1330 nm < 3,5 ps/(nm x km)
1550 nm < 19 ps/(nm x km)
Wave length 1312 nm
Mode field diameter at 1310 nm 9,3 + 0,5 m
Cladding diameter 125 + 1 m
Primary coating diameter 245 + 10 m
Cut-off wavelength < 1250 nm
Cladding concentricity error < 0,8 m
Cladding noncircularity < 1,0 %

POF and HCS-Fibre


Specification Fibre type POF P980/1000 Fibre type HCS K200/230
Core diameter 980 m 200 m
Numerical aperture 0,5 0,37
Typ. attenuation 650 nm 160 dB/km 10 db/km
850 nm - 8 dB/km
Min. Bandwidth 650 nm 10 MHz x 100 m 17 MHz x km
850 nm - 20 MHz x km
Wallthickness 1000 m 230 m
Fibres with other parameteres on request

650
FIBRE OPTIC DESIGN CODE acc. to DIN VDE 0888

1 2 3 4 5 6 7 8 9 10 11 12 13 14

Lg layerstranding

Bandwidth in MHz for 1 km


(GF) dispersion parameter
in: ps
nmxkm

Wavelength
B = 850 nm
F = 1300 nm
H = 1550 nm

Attenuation coefficient in dB/km

Cladding diameter in m

Core diameter in m of graded index fibre


Field diameter in m of single mode fibre

Design
E Single mode fibre
G Graded index fibre

Number of fibres
Number of fibres per buffer
Number of multifibre buffer

Y PVC-sheath
H Sheath with halogenfree material
B Armouring
BY Armouring with PVC-protective covering sheath
B2Y Armouring with PE-protective covering sheath

Y PVC-sheath
2Y PE-sheath
4Y PA-sheath
11Y PUR-sheath
(L)2Y PE-Laminated sheath
(ZN)2Y PE-sheath with nometallic strength member
(L)(ZN)2Y PE-Laminated sheath with nonmetallic strength member

F Filling of the cable core with


R
petroleum jelly
Q Swellingmaterial

S Metallic element in the cable core


V Tight buffer
K Composite buffer fibre
H Loose buffer nonfilled
W Loose buffer, filled
B Multifibre buffer nonfilled
D Multifibre buffer filled
I Indoor cable
A Outdoor cable
AT Outdoor fan out cable

651
COPPER DATA CABLES HELUKAT

Designation Page

HELUKAT 155 UTP solid 654

HELUKAT 155 U/UTP solid, UL 655

HELUKAT 300 U/UTP solid, UL 656

HELUKAT 100 U/UTP flex 657

HELUKAT 155 F/UTP solid 658

HELUKAT 100 F/UTP flex 659

HELUKAT 100-FE60 F/UTP solid 660

HELUKAT 200 F/UTP flex, UL 661

HELUKAT 200 SF/UTP solid 662

HELUKAT 200 SF/UTP duplex solid 663

HELUKAT 200 SF/UTP flex 664

HELUKAT 300 U/FTP flex, UL 665

HELUKAT 450 F/FTP solid 666

HELUKAT 450 F/FTP duplex solid 667

HELUKAT 500 F/FTP solid 668

HELUKAT 500 F/FTP duplex solid 669

HELUKAT 500 U/FTP flex 670

HELUKAT 600 S/FTP solid 671

HELUKAT 600 S/FTP duplex solid 672

HELUKAT 600 S/FTP flex 673

HELUKAT 600A S/FTP solid outdoor 674

HELUKAT 600E S/FTP solid, direct burial 675

HELUKAT 600AE S/FTP solid direct burial 676

HELUKAT 1200-7A S/FTP solid 677

HELUKAT 1200-7A S/FTP duplex solid 678

HELUKAT 1200 S/FTP solid 679

HELUKAT 1200 S/FTP duplex solid 680

HELUKAT 1500 S/FTP solid 681

HELUKAT 1500 S/FTP duplex solid 682

IBM type 1A 683


R

653
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 5e 155
U/UTP

Cable structure U/UTP 4x2xAWG 24/1 PVC


Inner conductor : 0,51 mm
Conductor material: Copper, bare
Core insulation: PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: -
Screen over stranding element: -
Screen 1 over stranding: -
Screen 2 over stranding: -
Outer sheath material: PVC
Outer diameter: app. 4,9 mm
Outer sheath colour: Grey

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 155 MHz
Loop resistance: 190 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 66 %

Typical values
Frequency (MHz) 10 16 62,5 100 155
Attenuation (dB/100m) 6,3 8,0 16,5 21,3 26,8
Next (db) 50,3 47,3 38,4 35,3 33,0
ACR (db) 44,0 39,3 21,9 14,0 6,2

Technical data
Weight: app. 26 kg/km
bending radius, repeated: 40 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,40 MJ/m
Copper weight: 17,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e

Application
HELUKAT155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s, or
ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels and platforms due
to their optimized construction.

Part no. 80053, U/UTP 4x2xAWG24/1 PVC (UTP)


Dimensions and specifications may be changed without prior notice.

654
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 5e 155
U/UTP UL

Cable structure U/UTP 4x2xAWG 24/1 PVC, UL


Inner conductor : 0,53 mm
Conductor material: Copper, bare
Core insulation: PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: -
Screen over stranding element: -
Screen 1 over stranding: -
Screen 2 over stranding: -
Outer sheath material: PVC
Outer diameter: app. 5,2 mm
Outer sheath colour: Grey

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 155 MHz
Loop resistance: 190 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 66 %

Typical values
Frequency (MHz) 10 16 62,5 100 155
Attenuation (db/100m) 6,1 7,7 15,2 19,9 22,7
Next (db) 65,0 63,0 53,0 40,0 37,0
ACR (db) 58,9 55,3 37,8 20,1 14,3

Technical data
Weight: app. 35 kg/km
bending radius, repeated: 42 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,43 MJ/m
Copper weight: 17,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

Application
HELUKAT155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves R
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction. This type is certified according UL because of the special PVC jacket

Part no. 802171, U/UTP 4x2xAWG24/1 PVC UL (UTP)


Dimensions and specifications may be changed without prior notice.

655
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 6 300
U/UTP UL

Cable structure U/UTP 4x2xAWG 24/1 PVC, UL


Inner conductor : 0,55 mm
Conductor material: Copper, bare
Core insulation: PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: Polyester foil over stranded bundle
Screen over stranding element: -
Screen 1 over stranding: -
Screen 2 over stranding: -
Outer sheath material: PVC
Outer diameter: app. 6,3 mm
Outer sheath colour: Grey

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 300 MHz
Loop resistance: 190 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 67 %

Typical values
Frequency (MHz) 10 16 62,5 100 155 200 300
Attenuation (db/100m) 5,6 7,0 14,3 18,2 22,9 26,0 32,5
Next (db) 72,0 70,0 65,0 63,0 60,0 57,0 55,0
ACR (db) 66,4 63,0 50,7 44,8 37,1 31,0 22,5

Technical data
Weight: app. 46 kg/km
bending radius, repeated: 55 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,68 MJ/m
Copper weight: 20,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

Application
HELUKAT300 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction. This type is certified according UL because of the special PVC jacket

Part no. 802172, U/UTP 4x2xAWG24/1 PVC UL (UTP)


Dimensions and specifications may be changed without prior notice.

656
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN-Cable
Category 5 100
U/UTP flex

Cable structure U/UTP 4x2xAWG 26/7 PVC


Inner conductor : 0,48 mm
Conductor material: Copper, bare
Core insulation: PO
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: -
Screen over stranding element: -
Screen 1 over stranding: -
Screen 2 over stranding: -
Outer sheath material: PVC
Outer diameter: app. 4,5 mm
Outer sheath colour: Grey similar to RAL 7035

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 74 %

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/10m) 0,9 1,2 2,4 3,1
Next (db) 53,0 50,0 41,0 38,0
ACR (db) 52,1 48,8 38,6 34,9

Technical data
Weight: app. 17 kg/km
bending radius, repeated: 35 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,527 MJ/m
Copper weight: 11,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5

Application
R
HELUKAT100 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16
Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT100 series can be manufactured quickly and easily with all
common RJ45 plugs.

Part no. 80055, U/UTP 4x2xAWG 26/7 PVC (UTP)


Dimensions and specifications may be changed without prior notice.

657
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 5e 155
F/UTP

Cable structure F/UTP 4x2xAWG 24/1 PVC


Inner conductor : 0,51 mm
Conductor material: Copper, bare
Core insulation: PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: Polyester foil over stranded bundle
Screen over stranding element: -
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: -
Drain wire: yes
Outer sheath material: PVC
Outer diameter: app. 5,9 mm
Outer sheath colour: Yellow similar to RAL 1021

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 155 MHz
Loop resistance: 170 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 69 %

Typical values
Frequency (MHz) 10 16 62,5 100 155
Attenuation (dB/100m) 5,9 7,6 15,7 20,3 22,0
Next (db) 59,0 53,0 44,0 40,0 40,0
ACR (db) 53,1 45,4 28,3 19,7 18,0

Technical data
Weight: app. 40 kg/km
bending radius, repeated: 48 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,40 MJ/m
Copper weight: 18,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e

Application
HELUKAT155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s, or
ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels and platforms due
to their optimized construction.

Part no. 80043, F/UTP 4x2xAWG24/1 PVC (FTP)


Dimensions and specifications may be changed without prior notice.

658
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 5 100
F/UTP flex

Cable structure F/UTP 4x2xAWG 26/7 FRNC


Inner conductor : 0,48 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: -
Screen over stranding element: -
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: -
Drain wire: yes
Outer sheath material: FRNC
Outer diameter: app. 5,3 mm
Outer sheath colour: Grey similar to RAL 7035

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 74 %

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/10m) 0,9 1,2 2,4 2,9
Next (db) 58,0 56,0 45,0 43,0
ACR (db) 57,1 54,8 42,6 40,1

Technical data
Weight: app. 31 kg/km
bending radius, repeated: 40 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,45 MJ/m
Copper weight: 14,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT100 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance R
reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16
Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT100 series can be manufactured quickly and easily with all
common RJ45 plugs.

Part no. 81278, F/UTP 4x2xAWG 26/7 FRNC (FTP)


Dimensions and specifications may be changed without prior notice.

659
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 5 100
F/UTP FE60

Cable structure F/UTP 4x2xAWG 23/1 FR-0H


Inner conductor : 0,57 mm
Conductor material: Copper, bare
Core insulation: PO + flame resistant tape
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: -
Screen over stranding element: PO tape
Screen 1 over stranding: Helical glasfibre tape
Screen 2 over stranding: Polyester foil, aluminium-lined
Drain wire: yes
Outer sheath material: LSZH
Outer diameter: app. 8,3 mm
Outer sheath colour: Red

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 188 Ohm/km max.
Mutual capacitance: 65 nF/km nom.
Rel. propagation velocity: 67 %

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 5,7 7,3 14,9 19,3
Next (db) 56,0 53,0 42,0 38,0
ACR (db) 50,3 45,7 27,1 18,7

Technical data
Weight: app. 75 kg/km
bending radius, repeated: 130 mm
Operating temperature range min.: -20C
Operating temperature range max.: +70C
Caloric load, approx. value: 0,72 MJ/m
Copper weight: 24,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT100-FE60 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16
Mbit/s, or ISDN absolutely trouble-free. Likewise, the thermal characteristics are perfectly suited to realize an isolation integrity according EN50200-FE60
due to their optimized construction.

Part no. 804045, F/UTP 4x2xAWG23/1 FRNC (FTP)


Dimensions and specifications may be changed without prior notice.

660
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 5e 200
F/UTP Flex, UL

Cable structure F/UTP 4x2xAWG 26/7 PVC, UL


Inner conductor : 0,48 mm
Conductor material: Copper, bare
Core insulation: PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: -
Screen over stranding element: -
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: -
Drain wire: yes
Outer sheath material: PVC
Outer diameter: app. 5,4 mm
Outer sheath colour: Grey similar to RAL 7035

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 200 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 67 %

Typical values
Frequency (MHz) 10 16 62,5 100 200
Attenuation (db/10m) 0,9 1,2 2,4 3,1 3,9
Next (db) 62,0 60,0 50,0 48,0 45,0
ACR (db) 61,1 58,8 47,6 44,9 41,1

Technical data
Weight: app. 30 kg/km
bending radius, repeated: 44 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,40 MJ/m
Copper weight: 15,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

Application R
HELUKAT200 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI,
token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT200 series can be manufactured quickly and
easily with all common RJ45 plugs. This type is certified according UL because of the special PVC jacket.

Part no. 802173, F/UTP 4x2xAWG26/7 PVC UL (FTP)


Dimensions and specifications may be changed without prior notice.

661
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 5e 200
SF/UTP

Cable structure SF/UTP 4x2xAWG 24/1 PVC


Inner conductor : 0,51 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: -
Screen over stranding element: -
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: Cu braid
Outer sheath material: PVC / FRNC
Outer diameter: app. 6,0 mm / app. 6,0 mm
Outer sheath colour: Grey similar to RAL 7035

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 200 MHz
Loop resistance: 185 Ohm/km max.
Mutual capacitance: 48 nF/km nom.
Rel. propagation velocity: 74 %

Typical values
Frequency (MHz) 10 16 62,5 100 200
Attenuation (dB/100m) 5,6 7,2 14,4 18,2 25,9
Next (db) 62,0 59,0 50,0 46,0 40,0
ACR (db) 56,4 51,8 35,6 27,8 14,6

Technical data
Weight: app. 50 kg/km
bending radius, repeated: 52 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,60 MJ/m / 0,48 MJ/m
Copper weight: 28,00 kg/km

Norms
81610:
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e
81609:
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant:
acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.

Part no. 81610, SF/UTP 4x2xAWG 24/1 PVC (S-FTP) 81609, SF/UTP 4x2xAWG 24/1 FRNC (S-FTP)
Dimensions and specifications may be changed without prior notice.

662
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 5e 200
SF/UTP duplex

Cable structure SF/UTP 2x(4x2xAWG 24/1) FRNC


Inner conductor : 0,51 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: -
Screen over stranding element: -
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: Cu braid
Outer sheath material: FRNC
Cable dimensions: app. 6,0 mm x 12,5 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 200 MHz
Loop resistance: 185 Ohm/km max.
Mutual capacitance: 48 nF/km nom.
Rel. propagation velocity: 74 %

Typical values
Frequency (MHz) 10 16 62,5 100 200
Attenuation (dB/100m) 5,6 7,2 14,4 18,2 25,9
Next (db) 62,0 59,0 50,0 46,0 40,0
ACR (db) 56,4 51,8 35,6 27,8 14,6

Technical data
Weight: app. 100 kg/km
bending radius, repeated: 52 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,96 MJ/m
Copper weight: 56,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

R
Application
HELUKAT200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.

Part no. 81123, SF/UTP 2x(4x2xAWG 24/1) FRNC (S-FTP)


Dimensions and specifications may be changed without prior notice.

663
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 5e 200
SF/UTP flex

Cable structure SF/UTP 4x2xAWG 26/7 FRNC


Inner conductor : 0,48 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: -
Screen over stranding element: -
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: Cu braid
Outer sheath material: FRNC
Outer diameter: app. 5,4 mm
Outer sheath colour: Grey similar to RAL 7035

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 200 MHz
Loop resistance: 300 Ohm/km max.
Mutual capacitance: 47 nF/km nom.
Rel. propagation velocity: 69 %

Typical values
Frequency (MHz) 10 16 62,5 100 200
Attenuation (dB/10m) 0,8 1,1 2,4 2,9 4,3
Next (db) 58,0 56,0 45,0 43,0 37,0
ACR (db) 57,2 54,9 42,6 40,1 32,7

Technical data
Weight: app. 40 kg/km
bending radius, repeated: 46 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,543 MJ/m
Copper weight: 24,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT200 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI,
token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT200 series can be manufactured quickly and
easily with all common RJ45 plugs.

Part no. 81254, SF/UTP 4x2xAWG 26/7 FRNC (S-FTP)


Dimensions and specifications may be changed without prior notice.

664
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 6 300
U/FTP, UL

Cable structure U/FTP 4x2xAWG 26/7 PVC, UL


Inner conductor : 0,48 mm
Conductor material: Copper, tinned
Core insulation: Foam-skin-PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Shielding 1: Polyester foil over stranded bundle
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: -
Screen 2 over stranding: -
Drain wire: yes
Outer sheath material: PVC
Outer diameter: app. 5,9 mm
Outer sheath colour: Grey similar to RAL 7035

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 300 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 45 nF/km nom.
Rel. propagation velocity: 77 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300
Attenuation (db/10m) 0,9 1,1 2,2 2,7 3,9 4,7
Next (db) 90,0 88,0 83,0 80,0 76,0 73,0
ACR (db) 89,1 86,9 80,8 77,3 72,1 68,3

Technical data
Weight: app. 37 kg/km
bending radius, repeated: 48 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,41 MJ/m
Copper weight: 20,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444

Application R
HELUKAT300 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI,
token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT300 series can be manufactured quickly and
easily with all common RJ45 plugs. This type is certified according UL because of the special PVC jacket.

Part no. 802174, U/FTP 4x2xAWG 26/7 PVC


Dimensions and specifications may be changed without prior notice.

665
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 6 450
F/FTP

Cable structure F/FTP 4x2xAWG 24/1 FRNC


Inner conductor : 0,52 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: -
Drain wire: yes
Outer sheath material: FRNC
Outer diameter: app. 7,4 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 450 MHz
Loop resistance: 165 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 450
Attenuation (dB/100m) 5,4 7,0 13,8 17,6 26,0 34,0 38,5
Next (db) 100,0 100,0 95,8 94,5 91,0 87,0 84,3
ACR (db) 94,6 93,0 82,0 76,9 65,0 53,0 45,8

Technical data
Weight: app. 50 kg/km
bending radius, repeated: 59 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,57 MJ/m
Copper weight: 24,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT450 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.

Part no. 82501, F/FTP 4x2xAWG 24/1 FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

666
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 6 450
F/FTP duplex

Cable structure F/FTP 2x(4x2xAWG 24/1) FRNC


Inner conductor : 0,52 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: -
Drain wire: yes
Outer sheath material: FRNC
Cable dimensions: app. 7,4 mm x 15,0 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 450 MHz
Loop resistance: 165 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 450
Attenuation (dB/100m) 5,4 7,0 13,8 17,6 26,0 34,0 38,5
Next (db) 100,0 100,0 95,8 94,5 91,0 87,0 84,3
ACR (db) 94,6 93,0 82,0 76,9 65,0 53,0 45,8

Technical data
Weight: app. 100 kg/km
bending radius, repeated: 59 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,14 MJ/m
Copper weight: 48,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT450 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
R
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.

Part no. 82502, F/FTP 2x4x2xAWG 24/1 FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

667
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 6A 500
F/FTP

Cable structure F/FTP 4x2xAWG 23/1 LSZH


Inner conductor : 0,57 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: -
Drain wire: yes
Outer sheath material: LSZH
Outer diameter: app. 7,5 mm
Outer sheath colour: Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 500 MHz
Loop resistance: 160 Ohm/km max.
Mutual capacitance: 45 nF/km nom.
Rel. propagation velocity: 80 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 250 300 500
Attenuation (db/100m) 5,7 7,2 14,2 18,1 25,8 29,0 31,9 41,8
Next (db) 100,0 100,0 100,0 97,4 92,9 91,4 90,2 86,9
ACR (db) 94,3 92,8 85,8 79,3 67,1 62,4 58,3 45,1

Technical data
Weight: app. 50 kg/km
bending radius, repeated: 100 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,55 MJ/m
Copper weight: 26,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT 500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight
cable channels and platforms due to their optimized construction.

Part no. 803378, F/FTP 4x2xAWG 23/1 LSZH (S-STP)


Dimensions and specifications may be changed without prior notice.

668
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Kategorie 6A 500
F/FTP duplex

Cable structure F/FTP 2x(4x2xAWG 23/1) LSZH (S-STP)


Inner conductor : 0,57 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: -
Drain wire: yes
Outer sheath material: LSZH
Cable dimensions: app. 7,8 mm x 15,9 mm
Outer sheath colour: Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 500 MHz
Loop resistance: 160 Ohm/km max.
Mutual capacitance: 45 nF/km nom.
Rel. propagation velocity: 80 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 250 300 500
Attenuation (db/100m) 5,7 7,2 14,2 18,1 25,8 29,0 31,9 41,8
Next (db) 100,0 100,0 100,0 97,4 92,9 91,4 90,2 86,9
ACR (db) 94,3 92,8 85,8 79,3 67,1 62,4 58,3 45,1

Technical data
Weight: app. 100 kg/km
bending radius, repeated: 100 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,13 MJ/m
Copper weight: 52,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT 500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
R
and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight
cable channels and platforms due to their optimized construction.

Part no. 803379, F/FTP 2x4x2xAWG 23/1 LSZH (S-STP)


Dimensions and specifications may be changed without prior notice.

669
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 6A 500
U/FTP, flex

Cable structure U/FTP 4x2xAWG 26/7 (stranded) LSZH


Inner conductor : 0,48 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: -
Screen 2 over stranding: -
Drain wire: yes
Outer sheath material: LSZH
Outer diameter: app. 5,8 mm
Outer sheath colour: Grey similar to RAL 7035

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 500 MHz
Loop resistance: 330 Ohm/km max.
Mutual capacitance: 54 nF/km nom.
Rel. propagation velocity: 78 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 250 500
Attenuation (dB/10m) 0,8 1,1 2,1 2,7 3,9 4,4 6,3
Next (db) 100,0 100,0 100,0 97,0 92,0 91,0 86,0
ACR (db) 99,2 98,9 97,9 94,3 88,1 86,6 79,7

Technical data
Weight: app. 35 kg/km
bending radius, repeated: 49 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,39 MJ/m
Copper weight: 15,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT 500 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet,
ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT500 series can be manufactured
quickly and easily with many common RJ45 plugs.

Part no. 804043, U/FTP 4x2xAWG 26/7 LSZH


Dimensions and specifications may be changed without prior notice.

670
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 7e 600
S/FTP

Cable structure S/FTP 4x2xAWG 23/1 FRNC


Inner conductor : 0,57 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: FRNC
Outer diameter: app. 7,5 mm
Outer sheath colour: Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 169 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0

Technical data
Weight: app. 60 kg/km
bending radius, repeated: 60 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,60 MJ/m
Copper weight: 28,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

R
Application
HELUKAT600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.

Part no. 80810, S/FTP 4x2xAWG 23/1 FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

671
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 7e 600
S/FTP duplex

Cable structure S/FTP 2x(4x2xAWG 23/1) FRNC


Inner conductor : 0,57 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: FRNC
Cable dimensions: app. 7,5 mm x 16,0 mm
Outer sheath colour: Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 169 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0

Technical data
Weight: app. 120 kg/km
bending radius, repeated: 60 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,20 MJ/m
Copper weight: 56,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.

Part no. 81446, S/FTP 2x(4x2xAWG 23/1) FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

672
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 7 600
S/FTP flex

Cable structure S/FTP 4x2xAWG 26/7 FRNC


Inner conductor : 0,48 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: FRNC
Outer diameter: app. 5,9 mm
Outer sheath colour: Grey similar to RAL 7035

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 600 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 45 nF/km nom.
Rel. propagation velocity: 77 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600
Attenuation (dB/10m) 0,8 1,0 2,0 2,6 4,0 4,9 6,3
Next (db) 96,0 96,0 95,0 94,0 88,0 86,0 80,0
ACR (db) 95,2 95,0 93,0 91,4 84,0 81,1 73,7

Technical data
Weight: app. 42 kg/km
bending radius, repeated: 55 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,47 MJ/m
Copper weight: 22,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

R
Application
HELUKAT600 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI,
token ring 4/16 Mbit/s or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT600 series can be manufactured quickly and
easily with all common RJ45 plugs.

Part no. 80294, S/FTP 4x2xAWG 26/7 FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

673
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable Outdoor


Category 7e 600A
S/FTP PVC/PVC

Cable structure S/FTP 4x2xAWG 23/1 PVC/PVC


Inner conductor : 0,58 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Inner sheath material: PVC
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: PVC
Outer diameter: app. 11,6 mm
Outer sheath colour: Black similar to RAL 9005

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 160 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0

Technical data
Weight: app. 153 kg/km
bending radius, repeated: 95 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Caloric load, approx. value: 2,62 MJ/m
Copper weight: 32,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e, Flame-retardant acc.
to IEC 60332-1

Application
HELUKAT 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT 600A with a double PVC jacket is constructed especially for outdoor applications
like laying at house walls or in cable lines.

Part no. 801147, S/FTP 4x2xAWG 23/1 PVC/PVC (S-STP)


Dimensions and specifications may be changed without prior notice.

674
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable direct Burial


Category 7e 600E
S/FTP PVC

Cable structure S/FTP 4x2xAWG 23/1 direct burial


Inner conductor : 0,58 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: PVC
Outer diameter: app. 9,8 mm
Outer sheath colour: Black

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 150 Ohm/km max.
Mutual capacitance: 42 nF/km nom.
Rel. propagation velocity: 79 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0

Technical data
Weight: app. 102 kg/km
bending radius, repeated: 100 mm
Operating temperature range min.: -45C
Operating temperature range max.: +65C
Caloric load, approx. value: 1,40 MJ/m
Copper weight: 32,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034

R
Application
HELUKAT 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT 600E with a cold resistant PVC jacket is constructed especially for outdoor
applications like laying at house walls or direct burial.

Part no. 802167, S/FTP 4x2xAWG23/1 PVC (S-STP)


Dimensions and specifications may be changed without prior notice.

675
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable direct Burial /


armoured
Category 7e 600AE
S/FTP FRNC/PE

Cable structure S/FTP 4x2xAWG 23/1 FRNC/PE


Inner conductor : 0,58 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Inner sheath material: FRNC
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
: Steel shaft
Outer sheath material: PE
Outer diameter: app. 12,2 mm
Outer sheath colour: Black

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 150 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0

Technical data
Weight: app. 155 kg/km
bending radius, repeated: 330 mm
Operating temperature range min.: -45C
Operating temperature range max.: +70C
Caloric load, approx. value: 2,30 MJ/m
Copper weight: 32,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e

Application
HELUKAT 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT 600AE with a FRNC/PE double jacket and the rodent protection is constructed
especially for outdoor and direct burial applications.

Part no. 802168, S/FTP 4x2xAWG 23/1 FRNC/PE (S-STP)


Dimensions and specifications may be changed without prior notice.

676
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 7A 1200
S/FTP

Cable structure S/FTP 4x2xAWG 23/1 LSZH


Inner conductor : 0,57 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: LSZH
Outer diameter: app. 7,5 mm
Outer sheath colour: Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 160 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 77 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000 1200
Attenuation (db/100m) 5,2 6,8 13,3 17,3 24,2 30,2 43,5 54,3 56,9 62,9
Next (db) 105,0 105,0 105,0 100,0 95,0 93,0 88,0 85,0 84,0 82,0
ACR (db) 99,8 98,2 91,7 82,7 70,8 62,8 44,5 30,7 27,1 19,1

Technical data
Weight: app. 60 kg/km
bending radius, repeated: 65 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,57 MJ/m
Copper weight: 30,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7A, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

R
Application
HELUKAT1200-7A data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet,
ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.

Part no. 803380, S/FTP 4x2xAWG 23/1 FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

677
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 7A 1200
S/FTP duplex

Cable structure S/FTP 2x(4x2xAWG 23/1) LSZH


Inner conductor : 0,57 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: LSZH
Cable dimensions: app. 16,0 mm x 7,5 mm
Outer sheath colour: Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 160 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 77 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000 1200
Attenuation (db/100m) 5,2 6,8 13,3 17,3 24,2 30,2 43,5 54,3 56,9 62,9
Next (db) 105,0 105,0 105,0 100,0 95,0 93,0 88,0 85,0 84,0 82,0
ACR (db) 99,8 98,2 91,7 82,7 70,8 62,8 44,5 30,7 27,1 19,1

Technical data
Weight: app. 120 kg/km
bending radius, repeated: 65 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,16 MJ/m
Copper weight: 60,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7A, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3

Application
HELUKAT1200-7A data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet,
ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.

Part no. 803381, S/FTP 2x(4x2xAWG 23/1) FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

678
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 8 1200
S/FTP

Cable structure S/FTP 4x2xAWG 22/1 FRNC


Inner conductor : 0,64 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: FRNC
Outer diameter: app. 7,7 mm
Outer sheath colour: Blue similar to RAL 5015

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %

Typical values
Frequency (Hz) 10 16 62,5 100 200 300 600 1000 1200
Attenuation (db/100m) 4,9 6,3 12,7 16,3 23,5 29,4 42,8 53,0 59,0
Next (db) 100,0 100,0 95,0 93,0 90,0 87,0 81,0 78,0 77,0
ACR (db) 95,1 93,7 82,3 76,7 66,5 57,6 38,2 25,0 18,0

Technical data
Weight: app. 66 kg/km
bending radius, repeated: 72 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,70 MJ/m
Copper weight: 40,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 8 (draft),
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

R
Application
HELUKAT1200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.

Part no. 81699, S/FTP 4x2xAWG 22/1 FRNC (S-FTP)


Dimensions and specifications may be changed without prior notice.

679
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable
Category 8 1200
S/FTP duplex

Cable structure S/FTP 2x(4x2xAWG 22/1) FRNC


Inner conductor : 0,64 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: FRNC
Cable dimensions: app. 7,7 mm x 16,5 mm
Outer sheath colour: Blue similar to RAL 5015

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 1000 1200
Attenuation (db/100m) 4,9 6,3 12,7 16,3 23,5 29,4 42,8 53,0 59,0
Next (db) 100,0 100,0 95,0 93,0 90,0 87,0 81,0 78,0 77,0
ACR (db) 95,1 93,7 82,3 76,7 66,5 57,6 38,2 25,0 18,0

Technical data
Weight: app. 133 kg/km
bending radius, repeated: 72 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,50 MJ/m
Copper weight: 80,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 8 (draft),
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT1200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.

Part no. 800647, S/FTP 2x(4x2xAWG 22/1) FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

680
Data, Network and Bus Technology / HELUKAT Copper data cables

Multimedia Cable
Category 8 1500
S/FTP

Cable structure S/FTP 4x2xAWG 22/1 FRNC


Inner conductor : 0,64 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: FRNC
Outer diameter: app. 7,7 mm
Outer sheath colour: Yellow

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 42 nF/km nom.
Rel. propagation velocity: 77 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 1000 1200 1500
Attenuation (db/100m) 4,2 6,3 12,7 16,5 21,5 27,5 41,7 54,4 59,8 66,2
Next (db) 110,0 110,0 110,0 110,0 110,0 105,0 95,0 85,0 80,0 74,0
ACR (db) 105,8 103,7 97,3 93,5 88,5 77,5 53,3 30,6 22,2 7,8

Technical data
Weight: app. 66 kg/km
bending radius, repeated: 68 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,74 MJ/m
Copper weight: 41,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 8 (draft),
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

R
Application
HELUKAT 1500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. That means applications such as multimedia (TV, Video, Data, Speach) are no problem
for this series.Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels and platforms due to their optimized
construction.

Part no. 802169, S/FTP 4x2xAWG 22/1 FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

681
Data, Network and Bus Technology / HELUKAT Copper data cables

Multimedia Cable
Category 8 1500
S/FTP duplex

Cable structure S/FTP 2x(4x2xAWG 22/1) FRNC


Inner conductor : 0,64 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Shielding 1: -
Screen over stranding element: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: FRNC
Cable dimensions: app. 7,7 mm x 16,2 mm
Outer sheath colour: Yellow

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 42 nF/km nom.
Rel. propagation velocity: 77 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 1000 1200 1500
Attenuation (db/100m) 4,2 6,3 12,7 16,5 21,5 27,5 41,7 54,4 59,8 66,2
Next (db) 110,0 110,0 110,0 110,0 110,0 105,0 95,0 85,0 80,0 74,0
ACR (db) 105,8 103,7 97,3 93,5 88,5 77,5 53,3 30,6 22,2 7,8

Technical data
Weight: app. 135 kg/km
bending radius, repeated: 68 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,50 MJ/m
Copper weight: 82,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 8 (draft),
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3

Application
HELUKAT1500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. That means applications such as multimedia (TV, Video, Data, Speach) are no problem
for this series.Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels and platforms due to their optimized
construction.

Part no. 802170, S/FTP 2x(4x2xAWG 22/1) FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

682
Data, Network and Bus Technology / HELUKAT Copper data cables

LAN Cable IVS


IBM P/N 33G2772

Cable structure IBM P/N 33G2772 type 1A


Inner conductor : 0,64 mm
Conductor material: Copper, bare
Core insulation: Foam-skin-PE
Number of cores: 4
Core colours: bk/og, rd/gn
Screen over stranding element: Polyester foil, aluminium-lined
Screen over stranding 1: Cu braid, tinned
Screen over stranding 2: -
Outer sheath material: PVC
Cable dimensions: app. 7,6 mm x 11,9 mm
Outer sheath colour: Black

Electrical data
Characteristic impedance: 150 Ohm
15 ohm at 3 to 20 MHz
185 Ohm
18.5 ohm at 38.4 kHz
270 Ohm
27 ohm at 9.6 kHz
Direct current resistance: 57,1 Ohm/km
Rel. propagation velocity: 78 %

Typical values
Frequency (MHz) 20 100 20 100 20 100
Attenuation (dB/100m) 7,4 18,7 4,9 12,3 7,4 18,7
Next (db) 80,0 60,0 50,0 39,0 60,0 49,0

Technical data
Weight: app. 85 kg/km
bending radius, repeated: 110 mm
Operating temperature range min.: -10C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,70 MJ/m
Copper weight: 38,00 kg/km

Application
HELUKABEL IVS types are used in the area of the IVS system, developed by IBM. They correspond to the wiring guidelines set by IBM.

Part no. 80068, IBM P/N 33G2772 type 1A


Dimensions and specifications may be changed without prior notice.
R

683
684
BUS CABLES

Designation Drag chain capability Page

Industrial Ethernet HELUKAT 600IND S/FTP solid, ROBUST 687

Industrial Ethernet HELUKAT 600IND S/FTP SHIPLINE 688

Industrial Ethernet HELUKAT 600IND S/FTP Robustflex, UL 689

Industrial Ethernet Standard Cable S/FTP Cat.6A, PVC 690

Industrial Ethernet HELUKAT 250S SF/UTP 4 pairs, drag chain 691

Industrial Ethernet HELUKAT 200IND SF/UTP Robustflex 692

Industrial Ethernet WK 105C 693

Industrial Ethernet HELUKAT 100S ECO SF/UTP 4-core, drag chain 694

Industrial Ethernet HELUKAT 100S ECO SF/UTP 4 pairs, drag chain 695

Industrial Ethernet HELUKAT 200S SF/UTP 4-cores, drag chain 696

Industrial Ethernet HELUKAT 200S SF/UTP 4 pairs, drag chain 697

Industrial Ethernet HELUKAT 100T SF/UTP Tordierflex 698

Industrial Ethernet PROFInet type A, PVC and PUR 699

Industrial Ethernet PROFInet type A, radiation resistant and armoured 700

Industrial Ethernet PROFInet type B hybrid 701

Industrial Ethernet PROFInet type B SHIPLINE 702

Industrial Ethernet PROFInet type B and C 703

Industrial Ethernet PROFInet type C Torsion 704

Profibus L2, fixed installation indoor 705

Profibus L2, fixed installation outdoor and robust 706

Profibus L2, direct burial, PVC/PE and armoured 707

Profibus L2, 7-wire 708

Profibus L2, drag chain 709

Profibus ET200X, Profibus ECOFAST 710

Profibus, SHIPLINE and high temperature 711

Profibus hybrid, DESINA 712

Profibus L2, torsion and festoon 713

Profibus PA 714

Profibus PA, armoured 715

Profibus PA, Long Distance 716


R
Profibus SK, indoor and outdoor 717

Profibus SK, FRNC and Robust (PUR) 718

Profibus SK, drag chain 719

FOUNDATION Fieldbus FF type A, basic 720

FOUNDATION Fieldbus FF type A, with device ground 721

FOUNDATION Fieldbus FF type A, with device ground and armouring 722

FOUNDATION Fieldbus FF type A, without device ground 723

Bus Cable HMCB200, PVC 724

Bus Cable HMCB500S, PVC 725

Bus Cable HMCB800, TPE 726

685
BUS CABLES

Designation Drag chain capability Page

Bus Cable USB S, PUR 727

Bus Cable USB L, PUR 728

Bus Cable USB 3.0, PUR 729

Bus Cable Coax 50 Ohm, PUR 730


CAN bus 0.22 mm , flexible
2
731

CAN bus 0,22 mm2 (pair stranded), flexible 732

CAN bus 0.25 mm , flexible, 105C


2
733

CAN bus 0.34 mm , flexible


2
734

CAN bus 0.34 mm2, flexible 735

CAN bus 0.50 mm , flexible


2
736

CAN bus 0.50 mm2, flexible 737

CAN bus 0.50 mm , direct burial


2
738

CAN bus 0.75 mm2, flexible 739

CAN bus 0.25 mm , drag chain


2
740

CAN bus 0.34 mm2 drag chain, UL 741

Interbus fixed installation, remote bus and installation remote bus 742

Interbus fixed installation, remote bus halogenfree 743

Interbus drag chain, remote bus and installation remote bus 744

Multibus I, highflexible 745

Multibus II, highflexible 746

ASI bus, EPDM 747

ASI bus, EPDM, Long Distance 748

ASI bus, PUR, UL/CSA 749

ASI bus, PUR, UL/CSA, Long Distance 750

ASI bus, TPE 751

AS-Interface for electrical cabinets, FLIH 752

DeviceNet PVC 753

DeviceNet FRNC 754

DeviceNet CPE 755

DeviceNet PUR 756

CC link bus 757

SafetyBUS p, FRNC and PUR 758

LON BUS, H122 and Y116 759

EIB bus, 4 cores, PVC 760

EIB bus, 4-core FRNC and 4-pair PVC 761

EIB bus, 4 cores, direct burial 762

KH bus, PVC and FRNC 763

686
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
ROBUST 600IND
S/FTP, Category 7e

Type Industrial Area


Cable structure S/FTP 4x2xAWG 23/1 PUR
Inner conductor diameter: Copper, bare (AWG 23/1)
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Stranding element: Double core
Shielding 1: -
Shielding 2: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: PUR
Cable external diameter: app. 8,2 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 148 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Relative propagation velocity: 78 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0

Technical data
Weight: app. 62 kg/km
bending radius, repeated: 85 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,74 MJ/m
Copper weight: 34,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3, Oil-resistant

Application
HELUKAT 600IND Cat 7e Robust is used for harsh industrial environments. Mechanically, this product exhibits excellent resistance to mineral oils, R
greases and cooling lubricants and has good microbe and hydrolysis resistance. Electrically, this cable is characterized by^high reserve capacity and
outstanding performance. This allows you to create services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, Token Ring 4/16
Mbit/s or ISDN without difficulty. These cable considerably exceed the requirement for compliance with Class B interference emission to EN55022,
as well as interference immunity to EN55024. This gives the series outstanding EMC characteristics.

Part no. 801197, S/FTP 4x2xAWG 23/1 PUR (S-STP)


Dimensions and specifications may be changed without prior notice.

687
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
SHIPLINE 600IND
S/FTP, Category 7

Type Marine and Offshore


Cable structure S/FTP 4x2xAWG 24/7 (stranded) FRNC
Inner conductor diameter: Copper, bare (AWG 24/7)
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Stranding element: Double core
Shielding 1: -
Shielding 2: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: FRNC
Cable external diameter: app. 9,1 mm 0,3 mm
Outer sheath colour: Grey similar to RAL 7035

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 600 MHz
Loop resistance: 168 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Relative propagation velocity: 72 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 600
Attenuation (dB/10m) 0,7 0,8 1,6 2,1 3,1 5,2
Next (db) 90,0 90,0 85,0 81,0 76,0 68,0
ACR (db) 89,3 89,2 83,4 78,9 72,9 62,8

Technical data
Weight: app. 85 kg/km
bending radius, repeated: 85 mm
Operating temperature range min.: -20C
Operating temperature range max.: +75C
Caloric load, approx. value: 0,80 MJ/m
Copper weight: 36,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034,
Halogen-free acc. to 60754-2, Corrosiveness acc. to EN50267-2-3, Oil-resistant

Application
HELUKAT 600IND Cat 7 Shipline is designed specially for use in shipbuilding and exceptionally well-suited for Ethernet applications. It guarantees
excellent transmission characteristics and may be used even under the harshest conditions.The cable listed here is certified by German Lloyd; this
means it is designed for flexible marine and offshore applications.

Part no. 803382, S/FTP 4x2xAWG 24/7 stranded FRNC (S-STP)


Dimensions and specifications may be changed without prior notice.

688
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
ROBUSTFLEX 600IND
S/FTP, Category 7

Type Industrial Patch Cables


Cable structure S/FTP 4x2xAWG 26/7 PUR
Inner conductor diameter: Copper, bare (AWG 26/7)
Core insulation: Foam-skin-PE
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Stranding element: Double core
Shielding 1: -
Shielding 2: Polyester foil, aluminium-lined
Screen 1 over stranding: Cu braid
Screen 2 over stranding: -
Outer sheath material: PUR
Cable external diameter: app. 6,4 mm 0,3 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 600 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 42 nF/km nom.
Relative propagation velocity: 64 %

Typical values
Frequency (MHz) 10 16 62,5 100 200 600
Attenuation (db/10m) 0,8 1,1 2,2 2,8 4,0 7,4
Next (db) 80,0 80,0 75,0 72,0 68,0 61,0
ACR (db) 79,2 78,9 72,8 69,2 64,0 53,6

Technical data
Weight: app. 48 kg/km
bending radius, repeated: 64 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,45 MJ/m
Copper weight: 28,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034,
Halogen-free acc. to 60754-2, Corrosiveness acc. to EN50267-2-3, Oil-resistant, AWM 20963 (80C/30V)

Application
HELUKAT600IND Cat 7 Robustflex is an Ethernet cable that, thanks to use of a halogen-free PU outer sheath, is ideal for harsh industrial surroundings. R
This cable is configurable with common RJ45 plugs (industrial and office version), as well as with some Sub-D and M12 plugs.

Part no. 802184, S/FTP 4x2xAWG 26/7 PUR (S-STP)


Dimensions and specifications may be changed without prior notice.

689
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
10GIG 500IND
S/FTP, Category 6A

Type Industrial Area


Cable structure S/FTP 4x2xAWG 22/1
Inner conductor diameter: Copper, bare (AWG 22/1)
Core insulation: Foam-skin-PE
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Stranding element: Double core
Shielding 1: Polyester foil over stranded bundle
Inner sheath material: PVC
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Foil + braid
Drain wire: yes
Outer sheath material: PVC
Cable external diameter: app. 9,6 mm 0,3 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 500 MHz
Conductor resistance, max.: 59 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km
Loop resistance: 118 Ohm/km max.
Mutual capacitance: 72 nF/km nom.
Test voltage: 0,7 kV
Relative propagation velocity: 62 %

Typical values
Frequency (MHz) 10 16 62,5 100 250 500
Attenuation (db/100m) 5,9 7,5 15,0 19,1 31,1 45,3
Next (dB) 60,3 57,2 48,4 45,3 39,3 34,3
PSNext (dB) 57,3 54,2 45,4 42,3 36,3 31,8

Technical data
Weight: app. 115 kg/km
bending radius, repeated: 80 mm
Operating temperature range min.: -40C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,69 MJ/m
Copper weight: 44,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A, Flame-retardant acc. to IEC 60332-3, CMG FT4

Application
HELUKAT 600IND 10GIG was designed specially for extreme industrial applications. The copper data cable is especially well-suited for Category 6A
Ethernet applications up to 10 Gigabits / 500 MHz (IEC61156-5). It guarantees excellent transmission characteristics and may be used even under
the harshest conditions. The cable listed here is based on PROFInet Type A. Thanks to the addtional inner sheath, the cable can be processed using
the quick contact method. This version with PVC jacket is designed specifically for fixed installation under difficult industrial conditions.

Part no. 803693, INDUSTRIAL ETHERNET CAT.6A 10GIG


Dimensions and specifications may be changed without prior notice.

690
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
Drag Chain 250S
SF/UTP, Category 6

Type Drag chain applications


Cable structure SF/UTP 4x2x0.15 mm (stranded) PUR
Inner conductor diameter: Copper, tinned (AWG 26/19)
Core insulation: PP
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Stranding element: Double core
Shielding 1: -
Inner sheath material: FRNC
Shielding 2: -
Total shielding: Foil + braid
Outer sheath material: PUR
Cable external diameter: app. 7,8 mm 0,2 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm bei 101 bis 250 MHz
Conductor resistance, max.: 140 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km
Loop resistance: 280 Ohm/km max.
Mutual capacitance: 52 nF/km nom.
Test voltage: 0,7 kV
Relative propagation velocity: 67 %

Typical values
Frequency (MHz) 10 16 62,5 100 250
Attentuation (db/10m) 0,9 1,2 2,4 2,9 4,9
Next (db) 59,3 56,2 47,4 44,3 38,3
ACR (db) 58,4 55,0 45,0 41,4 33,4

Technical data
Weight: app. 63 kg/km
bending radius, repeated: 60 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,35 MJ/m
Copper weight: 34,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
CMX 75C (shielded) R
Application
HELUKAT 250S trailing cable Cat 6 is designed for use in cable carriers and the recurring loads caused by moving machine components and provides
excellent transmission characteristics under extremely difficult conditions.

Part no. 803387, INDUSTRIAL ETHERNET CAT.6


Dimensions and specifications may be changed without prior notice.

691
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
ROBUSTFLEX 200IND
SF/UTP, Category 5e

Type Industrial Patch Cables


Cable structure SF/UTP 4x2xAWG 26/7 PUR
Inner conductor diameter: Copper, bare (AWG 26/7)
Core insulation: PO
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Stranding element: Double core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: -
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: Cu braid
Outer sheath material: PUR
Cable external diameter: app. 5,8 mm
Outer sheath colour: Grey similar to RAL 7035

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 200 MHz
Loop resistance: 260 Ohm/km max.
Mutual capacitance: 47 nF/km nom.
Relative propagation velocity: 74 %

Typical values
Frequency (MHz) 10 16 62,5 100 200
Attenuation (dB/10m) 0,8 1,1 2,4 2,9 4,3
Next (db) 58,0 56,0 45,0 43,0 37,0
ACR (db) 57,2 54,9 42,6 40,1 32,7

Technical data
Weight: app. 44 kg/km
bending radius, repeated: 46 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,54 MJ/m
Copper weight: 24,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc. to IEC 60332-1, Smoke density acc. to
IEC 61034, Halogen-free acc. to 60754-2, Oil-resistant

Application
HELUKAT 200IND Cat 5e Robustflex is used in harsh industrial surroundings and characterized by high reserve capacity and outstanding performance.
Mechanically, the halogen-free PU outer sheath makes it ideal for harsh industrial surroundings. This cable is configurable with common RJ45 plugs
(industrial and office version), as well as with various Sub-D and M12 plugs.

Part no. 800068, SF/UTP 4x2xAWG 26/7 PUR (S-FTP)


Dimensions and specifications may be changed without prior notice.

692
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
WK Industrial 105C 100IND
SF/UTP, Category 5e

Type Windenergy
Cable structure SF/UTP 2x2x0,75 mm (stranded)
Inner conductor diameter: Copper, tinned (AWG 22/7)
Core insulation: XLPE ray cross-linking
Core colours: wh, ye, bu, og
Stranding element: Star quad
Shielding 1: Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned
Outer sheath material: X-FRNC
Cable external diameter: app. 6,5 mm 0,2 mm
Outer sheath colour: Black similar to RAL 9005

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 60 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 52 nF/km nom.
Test voltage: 2 kV
Relative propagation velocity: 69 %

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 6,3 8,0 16,5 21,3
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 63,7 57,0 38,5 28,7

Technical data
Weight: app. 64 kg/km
bending radius, repeated: 52 mm
Operating temperature range min.: -40C
Operating temperature range max.: +105C *
Caloric load, approx. value: 0,89 MJ/m
Copper weight: 34,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Category 5, Flame-retardant acc. to IEC 60332-3, Halogen-free acc. to 60754-2, Corrosiveness acc. to
EN50267-2-3, UL-Syle 21281 80C/300V

Application R
HELUKAT 100IND Cat 5e WK Industrial 105C is designed specially for demanding temperature requirements such as those encountered in wind
turbines. Radiation cross-linking provides improved thermal stability as well good oil resitance.

Part no. 802293, INDUSTRIAL ETHERNET CAT.5


Dimensions and specifications may be changed without prior notice.

693
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
DRAG CHAIN ECO 100S
SF/UTP 4 core, Category 5e

Type Drag chain applications


Cable structure SF/UTP 4x1x0.15 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 26/19)
Core insulation: PO
Core colours: whbl, bl, whor, or
Stranding element: Star quad
Shielding 1: -
Shielding 2: PETP fleece
Total shielding: Foil + braid
Outer sheath material: PUR
Cable external diameter: app. 4,8 mm 0,2 mm
Outer sheath colour: Green

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 250 Ohm/km max.
Mutual capacitance: 51 nF/km nom.
Test voltage: 0,5 kV
Relative propagation velocity: 67 %

Typical values
Frequency (MHz) 10 16 62,5 100 155
Attentuation (db/100m) 9,5 12,1 24,8 32,0 41,0
Next (db) 50,0 48,0 38,5 35,3 30,0

Technical data
Weight: app. 30 kg/km
bending radius, repeated: 70 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,37 MJ/m
Copper weight: 17,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3, AWM 20963 (80C/30V)

Application
HELUKAT 100S Cat 5e drag chain Eco is designed in use in cable carriers and the recurring loads cause by moving machine components. Thanks to
the PU sheath, it also offers excellent resistance to common mineral oils, greases and cooling lubricants.

Part no. 82838, INDUSTRIAL ETHERNET CAT.5e


Dimensions and specifications may be changed without prior notice.

694
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
Drag chain ECO 100S
SF/UTP 4-pair, Category 5e

Type Drag chain applications


Cable structure SF/UTP 4x2x0.15 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 26/19)
Core insulation: PO
Core colours: whbu/bu, whog/og, whgn/gn, whbn/bn
Stranding element: Double core
Shielding 1: -
Shielding 2: PETP fleece
Total shielding: Foil + braid
Outer sheath material: PUR
Cable external diameter: app. 6,6 mm 0,2 mm
Outer sheath colour: Green

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 250 Ohm/km max.
Mutual capacitance: 48 nF/km nom.
Test voltage: 0,5 kV
Relative propagation velocity: 67 %

Typical values
Frequency (MHz) 10 16 62,5 100 155
Attentuation (db/100m) 9,5 12,1 24,8 32,0 41,0
Next (db) 50,0 48,0 38,5 35,3 30,0

Technical data
Weight: app. 56 kg/km
bending radius, repeated: 102 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,64 MJ/m
Copper weight: 31,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3, AWM 20963 (80C/30V)

Application
HELUKAT 100S Cat 5e drag chain Eco is designed for use in cable carriers and the recurring loads caused by moving machine components. Thanks
to the PU sheath, it also offers excellent resistance to common mineral oils, greases and cooling lubricants. R
Part no. 82839, INDUSTRIAL ETHERNET CAT.5e
Dimensions and specifications may be changed without prior notice.

695
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
DRAG CHAIN 200S
SF/UTP 4 core, Category 5

Type Drag Chain Patch Cables


Cable structure SF/UTP 4x1xAWG 24/19 (stranded) PUR
Inner conductor diameter: Copper, bare (AWG 24/19)
Core insulation: PP
Core colours: wh/bn, gn/ye
Stranding element: Quad
Shielding 1: Polyester foil over stranded bundle
Shielding 2: -
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: Cu braid
Outer sheath material: PUR
Cable external diameter: app. 6,2 mm 0,2 mm
Outer sheath colour: Green similar to RAL 6026

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 156 Ohm/km max.
Mutual capacitance: 51 nF/km nom.
Relative propagation velocity: 67 %

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/10m) 1,0 1,2 2,6 3,3
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 46,0 42,8 32,4 28,7

Technical data
Weight: app. 54 kg/km
bending radius, repeated: 75 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Caloric load, approx. value: 0,944 MJ/m
Copper weight: 30,00 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Oil-resistant

Application
HELUKAT 200S Cat 5 drag chain is designed for use in cable carriers and the extreme loads caused by moving machine components and provides
excellent transmission characteristics under the most difficult and extreme conditions. Thanks to the clever structure, it is also suitable mechanically
for use even in cable carriers with a high packing density. This cable configurable with conventional Sub-D plugs, as well as with various RJ45 plugs.

Part no. 800088, SF/UTP 4x1xAWG 24/19 PUR (S-FTP)


Dimensions and specifications may be changed without prior notice.

696
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
DRAG CHAIN 200S
SF/UTP 4 pair, Category 5

Type Drag Chain Patch Cables


Cable structure SF/UTP 4x2xAWG 24/19 PUR (stranded)
Inner conductor diameter: Copper, bare (AWG 24/19)
Core insulation: PE
Core colours: wh/bn, gn/ye, gy/pk, bu/rd
Stranding element: Double core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: -
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: Cu braid
Outer sheath material: PUR
Cable external diameter: app. 9,5 mm 0,2 mm
Outer sheath colour: Green similar to RAL 6026

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 156 Ohm/km max.
Mutual capacitance: 51 nF/km nom.
Relative propagation velocity: 67 %

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/10m) 1,0 1,2 2,6 3,3
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 46,0 42,8 32,4 28,7

Technical data
Weight: app. 110 kg/km
bending radius, repeated: 115 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Caloric load, approx. value: 2,08 MJ/m
Copper weight: 54,30 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Oil-resistant

Application
HELUKAT 200S Cat 5 drag chain is designed for use in cable carriers and the extreme loads caused by moving machine components and provides
excellent transmission characteristics under the most difficult and extreme conditions. Thanks to the clever structure, it is also suitable mechanically R
for use even in cable carriers with a high packing density. This cable is configurable with conventional Sub-D plugs, as well as with various RJ45 plugs.

Part no. 81155, SF/UTP 4x2xAWG 24/19 PUR (S-FTP)


Dimensions and specifications may be changed without prior notice.

697
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
TORDIERFLEX 100T
SF/UTP, Category 5

Type Torsion Patch Cables


Cable structure SF/UTP 4x2xAWG 26/19 PUR (stranded)
Inner conductor diameter: Copper, bare (AWG 26/19)
Core insulation: PP
Core colours: wh/bu, wh/og, wh/gn, wh/bn
Stranding element: Double core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: -
Screen 1 over stranding: Polyester foil, aluminium-lined
Screen 2 over stranding: Cu braid
Outer sheath material: PUR
Cable external diameter: app. 7,5 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 260 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Relative propagation velocity: 68 %

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/10m) 1,3 1,6 3,2 4,0
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 45,7 42,4 31,8 28,0

Technical data
Weight: app. 63 kg/km
bending radius, repeated: 56 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 1,234 MJ/m
Copper weight: 29,50 kg/km

Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034,
Halogen-free acc. to 60754-2, Oil-resistant, AWM Style 20236 80C/30V

Application
HELUKAT 100T Cat 5 Torsionflex is designed for applications with torsion loads, e.g. in robots, and characterized by high reserve capacity and
outstanding performance, even after exposure to extreme conditions. Thanks to the clever structure, it is also possible to achieve a long service life
mechanically. These cables are configurable with conventional Sub-D plugs, as well as with various RJ45 plugs.

Part no. 800067, SF/UTP 4x2xAWG 26/19 PUR (S-FTP)


Dimensions and specifications may be changed without prior notice.

698
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
PROFInet Type A
fixed installed + robust

Type Fixed installation, indoor Industrial Area


Cable structure 2x2x0.64 mm 2x2x0.64 mm
Inner conductor diameter: Copper, bare (AWG 22/1) Copper, bare (AWG 22/1)
Core insulation: PE PE
Core colours: wh, ye, bu, og wh, ye, bu, og
Stranding element: Star quad Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Inner sheath material: PVC FRNC
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PUR
Cable external diameter: app. 6,5 mm 0,2 mm app. 6,5 mm 0,2 mm
Outer sheath colour: Green similar to RAL 6018 Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 62 Ohm/km 62 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km 0,5 GOhm x km
Loop resistance: 115 Ohm/km max. 115 Ohm/km max.
Mutual capacitance: 50 nF/km nom. 50 nF/km nom.
Test voltage: 2 kV 2 kV

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 5,2 6,9 15,0 19,5
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 64,8 58,1 40,0 30,5

Technical data
Weight: app. 67 kg/km app. 64 kg/km
bending radius, repeated: 65 mm 65 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +70C
Caloric load, approx. value: 0,34 MJ/m 0,91 MJ/m
Copper weight: 32,00 kg/km 32,00 kg/km

Norms
Applicable standards: PROFInet Guideline PROFInet Guideline
Acc. to ISO/IEC 11801 Acc. to ISO/IEC 11801
Acc. to EN 50173
Category 5e
Acc. to EN 50173
Category 5e R
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: CMG 75C PLTC FT4 -
CSA standard: CSA FT 4 -

Application
HELUKAT PROFInet Type A Cat 5e for fixed installation in industrial networks, rugged. It guarantees excellent transmission characteristics and may
be used even under the harshest conditions. The cable listed here corresponds to PROFInet Type A; this means the version with PVC sheath is designed
for normal fixed installations and the version with PU sheath is for difficult fixed installations in harsh industrial environments.

Part no. 800653, PROFInet type A (SK) 801194, PROFInet type A (SK)
Dimensions and specifications may be changed without prior notice.

699
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
PROFInet Type A
radiation resistant + armoured

Type ray loaded areas Fixed installation, outdoor


Cable structure 2x2x0.64 mm 2x2x0.64 mm
Inner conductor diameter: Copper, bare (AWG 22/1) Copper, bare (AWG 22/1)
Core insulation: XLPE ray cross-linking PE
Core colours: wh, ye, bu, og wh, ye, bu, og
Stranding element: Star quad Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Inner sheath material: TPR ray cross-linking PVC
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Armouring: - Steel band
Outer sheath material: PUR PE
Cable external diameter: app. 6,5 mm 0,2 mm app. 9,3 mm 0,5 mm
Outer sheath colour: Green similar to RAL 6018 Black

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 62 Ohm/km 62 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km 0,5 GOhm x km
Loop resistance: 124 Ohm/km max. 115 Ohm/km max.
Mutual capacitance: 50 nF/km nom. 50 nF/km nom.
Test voltage: 2 kV 2 kV

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 5,2 6,9 15,0 19,5
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 64,8 58,1 40,0 30,5

Technical data
Weight: app. 63 kg/km app. 124 kg/km
bending radius, repeated: 100 mm 100 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +70C
Caloric load, approx. value: 0,29 MJ/m 2,14 MJ/m
Copper weight: 32,00 kg/km 31,00 kg/km

Norms
Applicable standards: PROFInet Guideline PROFInet Guideline
Acc. to ISO/IEC 11801 Acc. to ISO/IEC 11801
Acc. to EN 50173 Acc. to EN 50173
Category 5e Category 5e

Application
HELUKAT PROFInet Type A Cat 5e is radiation-resistant + armoured for fixed installation in industrial networks. It guarantees excellent transmission
characteristics and may be used even under the harshest conditions. The cables listed here correspond to PROFInet Type A and thanks to their special
construction with cross-linked PVC-inner sheath/PU outer sheath are well-suited for fixed applications inside irradiated areas, while the armoured
type with PVC inner sheath/PE outer sheath is ideal for areas with rodent problems.

Part no. 801195, PROFInet type A (SK) 801650, PROFInet type A (SK)
Dimensions and specifications may be changed without prior notice.

700
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
PROFInet Type B
hybrid

Type Mobile use


Cable structure 2x2x0,75 mm (stranded)+ 4x1,5qmm
Inner conductor diameter 1: Copper, bare (AWG 22/7)
Inner conductor diameter 2: Copper, bare (AWG 16/84)
Core insulation 1: Foam-skin-PE
Core insulation 2: PO
Core colours 1: wh, ye, bu, og
Core colours 2: Black
Stranding element 1: Double core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Polyester foil
Outer sheath material: FRNC
Cable external diameter: app. 10,3 mm 0,3 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 60 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 52 nF/km nom.
Test voltage: 2 kV

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 6,3 8,0 16,5 21,3
Next (db) 50,0 47,0 38,0 35,0
ACR (db) 43,7 39,0 21,5 13,7

Technical data
Weight: app. 153 kg/km
bending radius, repeated: 103 mm
Operating temperature range min.: -40C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,50 MJ/m
Copper weight: 94,00 kg/km

Norms
Applicable standards: PROFInet Guideline
Acc. to ISO/IEC 11801 R
Acc. to EN 50173
Category 5e
Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
Corrosiveness acc. to EN50267-2-3
Low-smoke acc. to EN50268-2
UL Style: UL Style 21282

Application
HELUKAT PROFInet Type B Cat 5e hybrid for flexible applications. The cable listed here corresponds to PROFInet Type B with integrated power supply
in a cable with halogen-free and flame-retardent construction.

Part no. 801651, PROFInet type B (SK)


Dimensions and specifications may be changed without prior notice.

701
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
PROFInet Typ B
SHIPLINE + FESTOON

Type Marine and Offshore FESTOON


Cable structure 2x2x0,34 qmm (stranded) 2x2x0.75 mm (stranded)
Inner conductor diameter: Copper, tinned (AWG 22/7) Copper, tinned (AWG 22/7)
Core insulation: PP PE
Core colours: wh, ye, bu, og wh, ye, bu, og
Stranding element: Star quad Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Inner sheath material: FRNC PVC
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: FRNC PVC
Cable external diameter: app. 6,5 mm 0,4 mm app. 6,5 mm 0,2 mm
Outer sheath colour: Green similar to RAL 6018 Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz 100 Ohm 5 %
Conductor resistance, max.: 60 Ohm/km 60 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km 0,5 GOhm x km
Loop resistance: 120 Ohm/km max. 120 Ohm/km max.
Mutual capacitance: 52 nF/km nom. 52 nF/km nom.
Test voltage: 2 kV 2 kV

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 6,0 7,6 16,0 21,0
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 64,0 57,4 39,0 29,0

Technical data
Weight: app. 68 kg/km app. 68 kg/km
bending radius, repeated: 50 mm 70 mm
Operating temperature range min.: -40C -10C
Operating temperature range max.: +70C +80C
Caloric load, approx. value: 0,45 MJ/m 1,20 MJ/m
Copper weight: 32,00 kg/km 32,00 kg/km

Norms
Applicable standards: PROFInet Guideline PROFInet Guideline
Acc. to ISO/IEC 11801 Acc. to ISO/IEC 11801
Acc. to EN 50173 Acc. to EN 50173
Category 5e Category 5e
Halogen-free acc. to 60754-2 Flame-retardant acc. to IEC 60332-3
Flame-retardant acc. to IEC 60332-3
Corrosiveness acc. to EN50267-2-3
Low-smoke acc. to EN50268-2
UL Style: CMG 75C PLTC FT4 CMG 75C or PLTC or AWM 21694 600V
CSA standard: CSA FT 4 CSA FT 4

Application
HELUKAT PROFInet Type B Cat 5e SHIPLINE + FESTOON designed specially for marine/offshore applications as well as FESTOON applications. The
SHIPLINE version is certified by the Germanische Lloyd and suitable for flexible marine and offshore applications.

Part no. 802185, PROFInet type B (SK) 803295, PROFInet type B (SK)
Dimensions and specifications may be changed without prior notice.

702
Data, Network and Bus Technology / HELUKABEL BUS-Cables

Industrial Ethernet
PROFInet Type B + C
flexible + high flexible

Type Mobile use Drag chain applications


Cable structure 2x2x0,75 mm (stranded) 2x2x0.75 mm (stranded)
Inner conductor diameter: Copper, tinned (AWG 22/7) Copper, tinned (AWG 22/7)
Core insulation: PE PE
Core colours: wh, ye, bu, og wh, ye, bu, og
Stranding element: Star quad Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Inner sheath material: PVC FRNC
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PUR
Cable external diameter: app. 6,5 mm 0,2 mm app. 6,5 mm 0,2 mm
Outer sheath colour: Green similar to RAL 6018 Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 62 Ohm/km 60 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km 0,5 GOhm x km
Loop resistance: 115 Ohm/km max. 115 Ohm/km max.
Mutual capacitance: 52 nF/km nom. 52 nF/km nom.
Test voltage: 2 kV 0,7 kV

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 6,0 7,6 16,0 21,0
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 64,0 57,4 39,0 29,0

Technical data
Weight: app. 67 kg/km app. 61 kg/km
bending radius, repeated: 100 mm 55 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,32 MJ/m 0,85 MJ/m
Copper weight: 32,00 kg/km 32,00 kg/km

Norms
Applicable standards: PROFInet Guideline PROFInet Guideline
Acc. to ISO/IEC 11801 Acc. to ISO/IEC 11801
Acc. to EN 50173
Category 5e
Acc. to EN 50173
Category 5e R
Flame-retardant acc. to IEC 60332-1 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
UL Style: CMG 75C PLTC FT4 CMX 75C (shielded)
CSA standard: CSA FT 4 -

Application
HELUKAT PROFInet Type B (flexible) + Type C (highly flexible) Cat 5e for use on moving parts and in cable carriers. The cables listed here correspond
to the PROFInet classifications Type B and Type C for moving cables and are designed to withstand mechanical loads.

Part no. 800654, PROFInet type B (SK) 800655, PROFInet type C (SK)
Dimensions and specifications may be changed without prior notice.

703
Industrial Ethernet
HELUKAT PROFInet Torsion Typ C (SK) 2x2xAWG22/19 PUR

Type Torsional applications


Cable structure 2x2x0,75 mm (stranded)
Innerconductordiameter: Copper,tinned (AWG22/19)
Coreinsulation: Foam-skin-PE
Corecolours: wh,ye,bu,og
Strandingelement: Starquad
Separator: Polyesterfoiloverstrandedbundle
Totalshielding: Cubraid,tinned
Outersheathmaterial: PUR
Cableexternaldiameter: app.6,5mm0,2mm
Outersheathcolour: GreensimilartoRAL6018

Electrical data
Characteristicimpedance: 100Ohm 15Ohmat1to100MHz
Conductorresistance,max.: 60Ohm/km
Insulationresistance,min.: 0,5GOhmxkm
Loopresistance: 120Ohm/kmmax.
Mutualcapacitance: 52nF/kmnom.
Testvoltage: 0,7kV

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (db/100m) 7,6 10,0 26,5 41,0
ELFEXT (db) 43,8 39,7 24,0 20,0

Technical data
Weight: app.54kg/km
bendingradius,repeated: 70mm
Operatingtemperaturerangemin.: -40C
Operatingtemperaturerangemax.: +80C
Caloricload,approx.value: 0,45MJ/m
Copperweight: 32,00kg/km

Norms
Applicablestandards: PROFInetGuideline+IEC61158-2
Category5e
Halogen-freeacc.to60754-1
Flame-retardantacc.toIEC60332-1-2
ULStyle: AWMStyle2116180C

Application
HELUKAT PROFInetTypeCCategory5eTORSIONoffersexcellenttransmissioncharacteristicsandisdesignedforapplicationswithtorsionloads,
24.02.2016/Dimensionsandspecificationsmaybechangedwithoutpriornotice.

e.g.inrobots.ThecablelistedherecorrespondstothePROFInetTypeCclassificationforcontinousmovement.

Part no. 802186, PROFInettypeC(SK)


Dimensionsandspecificationsmaybechangedwithoutpriornotice.
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus L2
Indoor

Type Fixed installation, indoor Fixed installation, indoor


Cable structure 1x2x0.64 mm 1x2x0.64 mm
Inner conductor diameter: Copper, bare (AWG 22/1) Copper, bare (AWG 22/1)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: rd, gn rd, gn
Stranding element: 2 cores + 2 fillers stranded together 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PVC
Cable external diameter: app. 7,8 mm 0,2 mm app. 7,8 mm 0,2 mm
Outer sheath colour: Grey similar to RAL 7001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 30 nF/km nom. 30 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 2,5 dB/km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/km 38,4 kHz < 4,0 dB/km
4 MHz < 22,0 dB/km 4 MHz < 22,0 dB/km
16 MHz < 42,0 dB/km 16 MHz < 42,0 dB/km

Technical data
Weight: app. 69 kg/km app. 69 kg/km
bending radius, repeated: 120 mm 120 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,99 MJ/m 0,99 MJ/m
Copper weight: 24,00 kg/km 24,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: CMX 75C (shielded) CMX 75C (shielded)
CSA standard: CSA FT1 CSA FT1

Application
HELUKABEL Profibus L2 Indoor is designed for fixed indoor installation in Profibus industrial networks. Depending on the application, the colour grey R
(special colour) or violet (standard colour) is availiable. Otherwise, the technical characteristics of the two products are identical.

Part no. 80384, Profibus L2 81448, Profibus L2


Dimensions and specifications may be changed without prior notice.

705
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
PROFIBUS L2 Outdoor + Industry
Outdoor + Industry

Type Fixed installation, outdoor Industrial Area


Cable structure 1x2x0.64 mm 1x2x0.64 mm
Inner conductor diameter: Copper, bare (AWG 22/1) Copper, bare (AWG 22/1)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: rd, gn rd, gn
Stranding element: 2 cores + 2 fillers stranded together 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PE PUR
Cable external diameter: app. 8,0 mm 0,4 mm app. 8,0 mm 0,4 mm
Outer sheath colour: Black similar to RAL 9005 Petrol similar to RAL 5018

Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 30 nF/km nom. 30 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 2,5 dB/km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/km 38,4 kHz < 4,0 dB/km
4 MHz < 22,0 dB/km 4 MHz < 22,0 dB/km
16 MHz < 42,0 dB/km 16 MHz < 42,0 dB/km

Technical data
Weight: app. 64 kg/km app. 67 kg/km
bending radius, repeated: 120 mm 120 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 2,26 MJ/m 1,52 MJ/m
Copper weight: 24,00 kg/km 24,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1

Application
HELUKABEL Profibus L2 Outdoor + Industry are special cables for use in Profibus industrial networks. The Outdoor version is designed for use in
open-air environments, i.e. can withstand wind, weather and sun (not for burial direcly in the ground). The Industry version is used in fixed installation
applications in harsh industrial environment. Mechanically, this product exhibits excellent resistance to mineral oils, greases and cooling lubricants
and has good microbe and hydrolysis resistance.

Part no. 80792, Profibus L2 81186, Profibus L2


Dimensions and specifications may be changed without prior notice.

706
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus L2 direct Burial
without + with Armouring

Type Direct burial Direct burial


Cable structure 1x2x0.64 mm 1x2x0.64 mm
Inner conductor diameter: Copper, bare (AWG 22/1) Copper, bare (AWG 22/1)
Core insulation: Foam-skin-PE Cell PE
Core colours: rd, gn rd, gn
Stranding element: 2 cores + 2 fillers stranded together 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle -
Inner sheath material: PVC PVC
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Armouring: - Steel band
Outer sheath material: PE PE
Cable external diameter: app. 10,0 mm 0,2 mm app. 10,6 mm 0,5 mm
Outer sheath colour: Black similar to RAL 9005 Black similar to RAL 9005

Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 5 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 30 nF/km nom. 30 nF/km nom.
Nominal voltage: - 250 V
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 2,5 dB/km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/km 38,4 kHz < 4,0 dB/km
3 MHz < 22,0 dB/km 4 MHz < 22,0 dB/km
20 MHz < 42,0 dB/km 16 MHz < 42,0 dB/km

Technical data
Weight: app. 92 kg/km app. 132 kg/km
bending radius, repeated: 150 mm 165 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 2,657 MJ/m 2,40 MJ/m
Copper weight: 24,00 kg/km 24,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170

Application
HELUKABEL Profibus L2 Direct Burial cables without + with armouring are special cables in the Profibus industrial networks. The version without R
armouring is for normal an direct cable burial in the ground. The version with steel tape armouring offers additional protection against rodents and is
the right choice for regions with such animals.

Part no. 82824, Profibus ERD 802177, Profibus L2


Dimensions and specifications may be changed without prior notice.

707
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus L2
7-wire

Type Mobile use


Cable structure 1x2x0.64 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 24/7)
Core insulation: Foam-skin-PE
Core colours: rd, gn
Stranding element: 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned
Outer sheath material: PVC
Cable external diameter: app. 7,8 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001

Electrical data
Characteristic impedance: 150 Ohm 10 %
Conductor resistance, max.: 86,7 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 173 Ohm/km max.
Mutual capacitance: 30 nF/km nom.
Test voltage: 1,5 kV
Attenuation: 9,6 kHz < 3,0 dB/km
38,4 kHz < 5,0 dB/km
4 MHz < 26,0 dB/km
16 MHz < 55,0 dB/km

Technical data
Weight: app. 75 kg/km
bending radius, repeated: 80 mm
Operating temperature range min.: -20C
Operating temperature range max.: +80C
Caloric load, approx. value: 1,20 MJ/m
Copper weight: 24,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571

Application
HELUKABEL Profibus L2 7-wire for mobile applications in Profibus industrial networks. With its core design and the special PVC sheath, the type
described here is suitable for normal mobile applications.

Part no. 800648, Profibus L2


Dimensions and specifications may be changed without prior notice.

708
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus L2
Drag Chain

Type Drag chain applications Drag chain applications


Cable structure 1x2x0.64 mm (stranded) 1x2x0.64 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 24/19) Copper, bare (AWG 24/19)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: rd, gn rd, gn
Stranding element: 2 cores + 2 fillers stranded together 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PUR PUR
Cable external diameter: app. 8,0 mm 0,4 mm app. 8,0 mm 0,4 mm
Outer sheath colour: Violet similar to RAL 4001 Petrol similar to RAL 5018

Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 80 Ohm/km 80 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 160 Ohm/km max. 160 Ohm/km max.
Mutual capacitance: 30 nF/km nom. 30 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 3,0 dB/km 9,6 kHz < 3,0 dB/km
38,4 kHz < 5,0 dB/km 38,4 kHz < 5,0 dB/km
4 MHz < 25,0 dB/km 4 MHz < 25,0 dB/km
16 MHz < 52,0 dB/km 16 MHz < 52,0 dB/km

Technical data
Weight: app. 65 kg/km app. 65 kg/km
bending radius, repeated: 63 mm 63 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,52 MJ/m 1,52 MJ/m
Copper weight: 25,00 kg/km 25,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1

Application
This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the cell and field area. For the information
exchange between different automation systems as well as for communication with the connected decentralized field units, serial field bus systems R
are used. The above mentioned types are suitable for drag chains (stranded).

Part no. 80267, Profibus L2 81003, Profibus L2


Dimensions and specifications may be changed without prior notice.

709
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus
ET200X + ECOFAST

Type Drag chain applications Drag chain applications


Cable structure 1x2x0.65 mm + 1x2x0.65 mm +
3x1x0.75 mm (stranded) 4x1x1.5 mm (stranded)
Inner conductor diameter 1: Copper, bare (AWG 22/19) Copper, bare (AWG 24/19)
Inner conductor diameter 2: Copper, bare (AWG 18/24) Copper, bare (AWG 18/84)
Core insulation 1: Foam-skin-PE Foam-skin-PE
Core insulation 2: PVC TPM
Core colours 1: rd, gn rd, gn
Core colours 2: bk, bu, gnye bk, bk, bk, bk
Stranding element 1: Double core 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: Foil + braid Foil + braid
Total shielding: Polyester foil -
Outer sheath material: PUR TPU
Cable external diameter: app. 9,7 mm 0,5 mm app. 11,5 mm 0,3 mm
Outer sheath colour: Petrol similar to RAL 5018 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 15 %
Conductor resistance, max.: 73 Ohm/km 73 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 145 Ohm/km max. 145 Ohm/km max.
Mutual capacitance: 30 nF/km nom. 30 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Relative propagation velocity: - 81 %
Attenuation: 9,6 kHz < 3,0 dB/Km 9,6 kHz 3,0 dB/km
38,4 kHz < 5,0 dB/Km 38,4 kHz 5,0 dB/km
4 MHz < 25,0 dB/Km 4 MHz 30,0 dB/km
16 MHz < 52,0 dB/Km 16 MHz 60,0 dB/km

Technical data
Weight: app. 105 kg/km app. 159 kg/km
bending radius, repeated: 140 mm 165 mm
Operating temperature range min.: -5C -15C
Operating temperature range max.: +60C +60C
Caloric load, approx. value: 1,973 MJ/m 2,835 MJ/m
Copper weight: 46,00 kg/km 90,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
UL Style: AWM Style 20236 AWM I/II A/B 80C 30V UL Style 20233
FT1

Application
HELUKABEL Profibus ET200X + Ecofast Hybrid cables are designed for continuous motion in cable carriers. The hybrid construction integrates the
power supply next to the Profibus in one cable. The type ET200X offers three 0,75mm power conductors, while the type Ecofast 4 has 1,5mm power
conductors and greater current-carrying capacity.

Part no. 82913, Profibus L2 800044, Profibus L2


Dimensions and specifications may be changed without prior notice.

710
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus
SHIPLINE and High Temperature

Type Marine and Offshore High temperature areas


Cable structure 1x2x0.75 mm (stranded) 1x2x0.64 mm
Inner conductor diameter: Copper, bare (AWG 22/7) Copper, bare (AWG 22/1)
Core insulation: Foam-skin-PE FEP
Core colours: rd, gn rd, gn
Stranding element: Double core 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle -
Inner sheath material: FRNC -
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: X-FRNC FEP
Cable external diameter: app. 8,0 mm 0,4 mm app. 7,2 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1,6 GOhm x km 1,6 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 29 nF/km nom. 28 nF/km nom.
Nominal voltage: 60 V 250 V
Test voltage: 1 kV 3,6 kV
Attenuation: 9,6 kHz < 2,5 dB/Km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/Km 38,4 kHz < 4,0 dB/km
4 MHz < 22,0 dB/Km 4 MHz < 22,0 dB/km
16 MHz < 42,0 dB/Km 16 MHz < 42,0 dB/km

Technical data
Weight: app. 84 kg/km app. 64 kg/km
bending radius, repeated: 80 mm 52 mm
Operating temperature range min.: -25C -50C
Operating temperature range max.: +80C +180C
Caloric load, approx. value: 1,26 MJ/m 0,30 MJ/m
Copper weight: 35,00 kg/km 24,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Flame-retardant acc. to IEC 60332-3
Flame-retardant acc. to IEC 60332-1

Application R
HELUKABEL Profibus Shipline is designed for marine/offshore applications and certified by German Lloyd. Thanks to use of stranded conductors,
this cable can be moved occasionally. The High-Temperature version is used in fixed installations with demanding temperature requirements, e.g. in
the vicinity of a hot furnace or near welding activities.

Part no. 802178, Profibus SHIPLINE 802179, Profibus high temperature


Dimensions and specifications may be changed without prior notice.

711
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
DESINA-HYBRID-BUS
hybrid

Type Hybrid Bus Cable


Cable structure 4x1.5 mm + 2xPOF
Conductor material Copper, bare, KL.6 = extra fine wire
Core insulation: TPM
Polymer optical fibre: 4x POF 980/1000
Core colours: Black
Core identification: Numbers
Total shielding: PETP fleece
Outer sheath material: TPU
Cable external diameter: app. 8,8 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001

Electrical data
Conductor resistance, max.: 13,7 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km
Test voltage: 3 kV

Optical characteristic
Fibre attenuation: 230 dB/km max. at 650 nm

Technical data
Weight: app. 120 kg/km
bending radius, repeated: 130 mm
Operating temperature range min.: -20C
Operating temperature range max.: +80C
Copper weight: 60,00 kg/km

Norms
Applicable standards: Detail specification for DESINA

Application
HELUKABEL DESINA-Hybrid-Bus is used for mobile applications in machinery. Use of a PU sheath provides excellent resistance to common mineral
oils, greases and cooling lubricants in industrial automation.

Part no. 81713, DESINA HYBRID BUS


Dimensions and specifications may be changed without prior notice.

712
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus L2
TORSION + FESTOON

Type Torsional applications Mobile use


Cable structure 1x2x0.80 mm (stranded) 1x2x0.65 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 22/19) Copper, bare (AWG 24/19)
Core insulation: Foam-skin-PE Cell PE
Core colours: rd, gn rd, gn
Stranding element: 2 cores + filler 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PUR PVC
Cable external diameter: app. 8,0 mm 0,4 mm app. 8,0 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001 Petrol similar to RAL 5018

Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 49 Ohm/km 66,5 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1,6 GOhm x km
Loop resistance: 98 Ohm/km max. 133 Ohm/km max.
Mutual capacitance: 29 nF/km nom. 28 nF/km nom.
Test voltage: 3,6 kV 2 kV
Relative propagation velocity: - 81 %
Attenuation: 9,6 kHz < 3,0 dB/km 9,6 kHz 3,0 dB/km
38,4 kHz < 5,0 dB/km 38,4 kHz 4,0 dB/km
4 MHz < 25,0 dB/km 4 MHz 25,0 dB/km
16 MHz < 51,0 dB/km 16 MHz 49,0 dB/km

Technical data
Weight: app. 66 kg/km app. 64 kg/km
bending radius, repeated: 100 mm 70 mm
Operating temperature range min.: -25C -40C
Operating temperature range max.: +75C +60C
Caloric load, approx. value: 0,89 MJ/m 1,09 MJ/m
Copper weight: 32,00 kg/km 23,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Flame-retardant acc. to EN 50265-2-1
Flame-retardant acc. to IEC 60332-1
UL Style: CMX 75C (shielded) CMG 75C or CL2 or AWM 20201 600V
CSA standard: - CSA FT 4
R
Application
HELUKABEL Profibus Torsion is used in mobile applications in robots. The special torsion construction allows this cable to be twisted (torsioned) and
is halogen-free thanks to use PU sheath. The Festoon version is used for hanging/moving loads in garland applications.

Part no. 800109, Profibus L2 800649, Profibus L2


Dimensions and specifications may be changed without prior notice.

713
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus PA

Type Hazardous areas Non-hazardous areas


Cable structure 1x2x1.0/2.55 mm 1x2x1.0/2.55 mm
Inner conductor diameter: Copper, bare (AWG 18/1) Copper, bare (AWG 18/1)
Core insulation: PE PE
Core colours: rd, gn rd, gn
Stranding element: 2 cores + 2 fillers stranded together 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PVC
Cable external diameter: app. 7,6 mm 0,2 mm app. 7,6 mm 0,2 mm
Outer sheath colour: Blue Black

Electrical data
Characteristic impedance: 100 Ohm 20 % 100 Ohm 20 %
Conductor resistance, max.: 22 Ohm/km 22 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 44 Ohm/km max. 44 Ohm/km max.
Mutual capacitance: 60 nF/km nom. 60 nF/km nom.
Nominal voltage: 300 V 300 V
Test voltage: 2,5 kV 2,5 kV
Attenuation: 39 kHz 3,0 dB/km 39 kHz 3,0 dB/km

Technical data
Weight: app. 76 kg/km app. 76 kg/km
bending radius, repeated: 140 mm 140 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 0,95 MJ/m 0,95 MJ/m
Copper weight: 44,00 kg/km 44,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571 UL Style 2571

Application
HELUKABEL Profibus PA is used for normal requirements in the process automation field (chemical industry). The colour blue identifies it as suitable
for use in potentially explosive areas (and ATEX/ Class II, EX-i/ EN 60079-14). For other applications, the colour black is usually selected.

Part no. 82835, Profibus PA 82836, Profibus PA


Dimensions and specifications may be changed without prior notice.

714
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus PA
armoured

Type Hazardous areas Non-hazardous areas


Cable structure 1x2x1.0/2.55 mm 1x2x1.0/2.55 mm
Inner conductor diameter: Copper, bare (AWG 18/1) Copper, bare (AWG 18/1)
Core insulation: PE PE
Core colours: rd, gn rd, gn
Stranding element: 2 cores + 2 fillers stranded together 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Inner sheath material: PVC PVC
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Armouring: Steel band Steel band
Outer sheath material: PVC PVC
Cable external diameter: app. 10,2 mm 0,2 mm app. 10,2 mm 0,2 mm
Outer sheath colour: Blue Black

Electrical data
Characteristic impedance: 100 Ohm 15 % 100 Ohm 15 %
Conductor resistance, max.: 22 Ohm/km 22 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 44 Ohm/km max. 44 Ohm/km max.
Mutual capacitance: 55 nF/km nom. 55 nF/km nom.
Nominal voltage: 300 V 300 V
Test voltage: 2,5 kV 2,5 kV
Attenuation: 39 kHz 3,0 dB/km 39 kHz 3,0 dB/km

Technical data
Weight: app. 170 kg/km app. 170 kg/km
bending radius, repeated: 140 mm 200 mm
Operating temperature range min.: -20C -20C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,95 MJ/m 1,95 MJ/m
Copper weight: 45,00 kg/km 45,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1

Application
HELUKABEL Profibus PA Armoured finds use in areas with rodent such as rats, nutria etc. but also offers additional protection against all other outside
mechanical influences thanks to it steel tape armouring. The colour blue identifies it as suitable for use in potentially explosive areas (and ATEX/ Class
II, EX-i/EN 60079-14). For other applications, the colour black is usually selected. R
Part no. 802180, Profibus PA 802181, Profibus PA
Dimensions and specifications may be changed without prior notice.

715
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus PA
Long Distance

Type Hazardous areas Non-hazardous areas


Cable structure 1x2x1.6/3.2 mm 1x2x1.6/3.2 mm
Inner conductor diameter: Copper, bare (AWG 16/7) Copper, bare (AWG 16/7)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: rd, gn rd, gn
Stranding element: 2 cores + 2 fillers stranded together 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PVC
Cable external diameter: app. 9,5 mm 0,3 mm app. 9,5 mm 0,3 mm
Outer sheath colour: Blue Black

Electrical data
Characteristic impedance: 100 Ohm 20 % 100 Ohm 20 %
Conductor resistance, max.: 24 Ohm/km 24 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 48 Ohm/km max. 48 Ohm/km max.
Mutual capacitance: 60 nF/km nom. 60 nF/km nom.
Nominal voltage: 300 V 300 V
Test voltage: 1 kV 1 kV
Attenuation: 39 kHz 2,7 dB/km 39 kHz 2,7 dB/km

Technical data
Weight: app. 131 kg/km app. 131 kg/km
bending radius, repeated: 100 mm 100 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,57 MJ/m 1,57 MJ/m
Copper weight: 62,00 kg/km 62,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: UL Style 2571 UL Style 2571

Application
HELUKABEL Profibus PA Long Distance is used for especially long transmission distances in process networks. It uses a larger conductor cross-section
to satisfy the attenuation requirements. The colour blue identifies it as suitable for use in potentially explosive areas (and ATEX/Class II, EX-i/EN
60079-14). For other applications, the colour black is usually selected.

Part no. 800650, Profibus PA 800715, Profibus PA


Dimensions and specifications may be changed without prior notice.

716
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus SK
Indoor + Outdoor

Type Fixed installation, indoor Fixed installation, outdoor


Cable structure 1x2x0.64 mm 1x2x0.64 mm
Inner conductor diameter: Copper, bare (AWG 22/1) Copper, bare (AWG 22/1)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: rd, gn rd, gn
Stranding element: Double core Double core
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Inner sheath material: PVC PVC
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PE
Cable external diameter: app. 8,0 mm 0,4 mm app. 8,0 mm 0,4 mm
Outer sheath colour: Violet similar to RAL 4001 Black similar to RAL 9005

Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 35 nF/km nom. 35 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 2,5 dB/km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/km 38,4 kHz < 4,0 dB/km
4,0 MHz < 22,0 dB/km 4 MHz < 22,0 dB/km
16,0 MHz < 42,0 dB/km 16 MHz < 42,0 dB/km

Technical data
Weight: app. 79 kg/km app. 65 kg/km
bending radius, repeated: 120 mm 120 mm
Operating temperature range min.: -40C -20C
Operating temperature range max.: +80C +70C
Caloric load, approx. value: 1,068 MJ/m 1,451 MJ/m
Copper weight: 24,00 kg/km 24,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to IEC 60332-3 Halogen-free acc. to 60754-2
UL Style: CMG 75C or CL3 or AWM 21694 600V -
CSA standard: CSA FT 4 -

Application R
HELUKABEL Profibus SK Indoor + Outdoor have a special structure for processing with the Fast Connect Stripping Tool from Siemens. The indoor
version is used for normal requirements in fixed installation applications in equipment; the Outdoor version is used in open-air applications, i.e. can
withstand wind, weather and sun (not for burial directly in the ground).

Part no. 81903, Profibus SK 81904, Profibus SK


Dimensions and specifications may be changed without prior notice.

717
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus SK
FRNC + Robust

Type Fixed installation, indoor Industrial Area


Cable structure 1x2x0.64 mm 1x2x0.64 mm
Inner conductor diameter: Copper, bare (AWG 22/1) Copper, bare (AWG 22/1)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: rd, gn rd, gn
Stranding element: Double core Double core
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Inner sheath material: FRNC FRNC
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: FRNC PUR
Cable external diameter: app. 8,0 mm 0,4 mm app. 8,0 mm 0,4 mm
Outer sheath colour: Violet similar to RAL 4001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 35 nF/km nom. 35 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 2,5 dB/km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/km 38,4 kHz < 4,0 dB/km
4 MHz < 22,0 dB/km 4 MHz < 22,0 dB/km
16 MHz < 42,0 dB/km 16 MHz < 42,0 dB/km

Technical data
Weight: app. 73 kg/km app. 71 kg/km
bending radius, repeated: 160 mm 120 mm
Operating temperature range min.: -25C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,203 MJ/m 1,574 MJ/m
Copper weight: 24,00 kg/km 24,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to IEC 60332-1
UL Style: CM 750C (shielded) AWM Style 20236 AWM I/II A/B 80C 30V
FT1
CSA standard: - CSA FT1

Application
HELUKABEL Profibus SK FRNC + Robust has a special structure for processing with the Fast Connect Stripping Tool from Siemens. The FRNC version
is used to satisfy halogen-free and flame-retardent requirements in buildings. The Rpbust version is used in harsh industrial environments and offers
excellent resistance to mineral oils, greases and cooling lubricants.

Part no. 81501, Profibus SK 81905, Profibus SK


Dimensions and specifications may be changed without prior notice.

718
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Profibus SK
Drag Chain

Type Drag chain applications Drag chain applications


Cable structure 1x2x0.65 mm (stranded) 1x2x0.65 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 24/19) Copper, bare (AWG 24/19)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: rd, gn rd, gn
Stranding element: Double core Double core
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Inner sheath material: PVC PVC
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PUR PUR
Cable external diameter: app. 8,0 mm 0,4 mm app. 8,0 mm 0,4 mm
Outer sheath colour: Violet similar to RAL 4001 Petrol similar to RAL 5018

Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 67 Ohm/km 67 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 134 Ohm/km max. 134 Ohm/km max.
Mutual capacitance: 35 nF/km nom. 35 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 3,0 dB/km 9,6 kHz < 3,0 dB/km
38,4 kHz < 5,0 dB/km 38,4 kHz < 5,0 dB/km
4 MHz < 25,0 dB/km 4 MHz < 25,0 dB/km
16 MHz < 52,0 dB/km 16 MHz < 52,0 dB/km

Technical data
Weight: app. 70 kg/km app. 70 kg/km
bending radius, repeated: 100 mm 100 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,53 MJ/m 1,53 MJ/m
Copper weight: 25,00 kg/km 25,00 kg/km

Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: CMX 75C (shielded) CMX 75C (shielded)
CSA standard: CSA FT1 CSA FT1
R
Application
HELUKABEL Profibus SK drag chain is designed for continous motion in cable carriers and has a special structure for processing with the Fast Connect
Stripping Tool from Siemens. Thanks to the PU sheath, it also offers excellent resistance to common mineral oils, greases and cooling lubricants.
Depending on the application, the colour petrol or violet is availiable.

Part no. 801659, Profibus SK 81906, Profibus SK


Dimensions and specifications may be changed without prior notice.

719
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
FOUNDATION Fieldbus
Basic

Type process automation


Cable structure 1x2x1.1/2,55-100 LI
Inner conductor diameter: Copper, bare (AWG 18/7)
Core insulation: PO
Core colours: or, bl
Stranding element: 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned
Drain wire: yes
Outer sheath material: PVC
Cable external diameter: app. 8,0 mm 0,3 mm
Outer sheath colour: Orange

Electrical data
Characteristic impedance: 100 Ohm 20 Ohm
Conductor resistance, max.: 22 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 44 Ohm/km max.
Mutual capacitance: 60 nF/km nom.
Nominal voltage: 300 V
Test voltage: 1,5 kV
Attenuation: 39 kHz 3,4 dB/km

Technical data
Weight: app. 85 kg/km
bending radius, repeated: 80 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 1,22 MJ/m
Copper weight: 45,00 kg/km

Norms
Applicable standards: Foundation Fieldbus Spec. FF-816-1.4
Flame-retardant acc. to IEC 60332-3
UL Style: CMG 75C PLTC FT4
CSA standard: CSA FT 4

Application
HELUKABEL FOUNDATION Fieldbus Basic for normal requirements in this industrial networks. Thanks to use of stranded conductors, this cable can
be moved occasionally and satisfies the usual American requirements for such networks.

Part no. 803354, Foundation Fieldbus Basic


Dimensions and specifications may be changed without prior notice.

720
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
FOUNDATION Fieldbus
Type A + gnye

Type process automation


Cable structure 1x2x1.1/2,85-100 LI + 1x0,8 gnye
Inner conductor diameter 1: Copper, bare (AWG 18/41)
Inner conductor diameter 2: Copper, bare (AWG 18/41)
Core insulation 1: XLPE ray cross-linking
Core insulation 2: PVC
Core colours 1: bu, bn
Core colours 2: gn/ye
Stranding element 1: Double core
Shielding 1: -
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned
Drain wire: yes
Outer sheath material: PVC
Cable external diameter: app. 7,9 mm 0,3 mm
Outer sheath colour: Yellow

Electrical data
Characteristic impedance: 100 Ohm 20 Ohm
Conductor resistance, max.: 24 Ohm/km
Insulation resistance, min.: 2 GOhm x km
Loop resistance: 48 Ohm/km max.
Mutual capacitance: 65 nF/km nom.
Nominal voltage: 300 V
Test voltage: 1,5 kV
Attenuation: 39 kHz 3,4 dB/km

Technical data
Weight: app. 84 kg/km
bending radius, repeated: 80 mm
Operating temperature range min.: -25C
Operating temperature range max.: +105C
Caloric load, approx. value: 1,00 MJ/m
Copper weight: 49,00 kg/km

Norms
Applicable standards: Foundation Fieldbus Spec. FF-816-1.4
Flame-retardant acc. to IEC 60332-3
UL Style: CMG 105 or CL3 FT4
CSA standard: CSA FT 4
R
Application
HELUKABEL FOUNDATION Fieldbus Type A + gnge offers an additional conductor in the structure in compliance with the FF specification. Thanks
to use of stranded conductors, this cable can be moved occasionally and satisfies the usual American requirements for such networks.

Part no. 801191, Foundation Fieldbus FF A


Dimensions and specifications may be changed without prior notice.

721
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
FOUNDATION Fieldbus
Type A armoured

Type process automation


Cable structure 1x2x1.1/2,85-100 LI + 1x0,8 gnye, armoured
Inner conductor diameter 1: Copper, bare (AWG 18/41)
Inner conductor diameter 2: Copper, bare (AWG 18/37)
Core insulation 1: XLPE ray cross-linking
Core insulation 2: PVC
Core colours 1: bu, bn
Core colours 2: gn/ye
Stranding element 1: Double core
Shielding 1: -
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Polyester foil, aluminium-lined
Drain wire: yes
Armouring: Corrugated copper tube
Outer sheath material: PVC
Cable external diameter: app. 12,3 mm 0,3 mm
Outer sheath colour: Yellow

Electrical data
Characteristic impedance: 100 Ohm 20 Ohm
Conductor resistance, max.: 24 Ohm/km
Insulation resistance, min.: 2 GOhm x km
Loop resistance: 48 Ohm/km max.
Mutual capacitance: 65 nF/km nom.
Nominal voltage: 300 V
Test voltage: 1,5 kV
Attenuation: 39 kHz 3,4 dB/km

Technical data
Weight: app. 187 kg/km
bending radius, repeated: 130 mm
Operating temperature range min.: -25C
Operating temperature range max.: +105C
Caloric load, approx. value: 1,65 MJ/m
Copper weight: 125,00 kg/km

Norms
Applicable standards: Foundation Fieldbus Spec. FF-816-1.4
Flame-retardant acc. to IEC 60332-3
UL Style: CMG 105C or PLTC FT4 Sun Res
CSA standard: CSA FT 4

Application
HELUKABEL FOUNDATION Type A Armoured finds use in areas with rodents such as rats, nutria etc. but also offers additional protection against
all other outside mechanical influences thanks to its corrugated tape armouring. Thanks to use of stranded conductors, this cable can be moved
occasionally and satisfies the usual American requirements for such networks.

Part no. 801192, Foundation Fieldbus FF A


Dimensions and specifications may be changed without prior notice.

722
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
FOUNDATION Fieldbus
Type A

Type process automation


Cable structure 1x2x1.1/2,85-100 LI
Inner conductor diameter: Copper, bare (AWG 18/37)
Core insulation: XLPE ray cross-linking
Core colours: bu, bn
Stranding element: Double core
Shielding 1: -
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned
Drain wire: yes
Outer sheath material: PVC
Cable external diameter: app. 7,9 mm 0,3 mm
Outer sheath colour: Yellow

Electrical data
Characteristic impedance: 100 Ohm 20 Ohm
Conductor resistance, max.: 24 Ohm/km
Insulation resistance, min.: 2 GOhm x km
Loop resistance: 48 Ohm/km max.
Mutual capacitance: 65 nF/km nom.
Nominal voltage: 300 V
Test voltage: 1,5 kV
Attenuation: 39 kHz 3,4 dB/km

Technical data
Weight: app. 89 kg/km
bending radius, repeated: 80 mm
Operating temperature range min.: -40C
Operating temperature range max.: +105C
Caloric load, approx. value: 1,05 MJ/m
Copper weight: 42,00 kg/km

Norms
Applicable standards: Foundation Fieldbus Spec. FF-816-1.4
Flame-retardant acc. to IEC 60332-3
UL Style: CMG 105 or CL3 FT4
CSA standard: CSA FT 4

Application
HELUKABEL FOUNDATION Fieldbus Type A for normal requirements in this industrial network. Thanks to use of stranded conductors, this cable
can be moved occasionally and satisfies the usual American requirements for such networks. R
Part no. 801193, Foundation Fieldbus FF A
Dimensions and specifications may be changed without prior notice.

723
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
HMCB200
fixed installed

Type Fixed installation, indoor


Cable structure 2x2x0,22qmm
Inner conductor diameter: Copper, bare (AWG 22/7)
Core insulation: Foam-skin-PE
Core colours: gn, ye, pk, bu
Stranding element: Double core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned
Outer sheath material: PVC
Cable external diameter: app. 6,8 mm 0,15 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 90 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 180 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Test voltage: 0,5 kV

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (db/100m) 8,0 10,0 20,0 27,0
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 39,0 34,0 15,0 5,0

Technical data
Weight: app. 63 kg/km
bending radius, repeated: 70 mm
Operating temperature range min.: -20C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,92 MJ/m
Copper weight: 35,00 kg/km

Norms
Applicable standards: Flame-retardant acc. to IEC 60332-1
UL Style: AWM Style 2502 AWM I/II A/B 80C 30V FT1

Application
HELUKABEL HMCB200 for fixed installation and slight occasional movement, range up to 100m. This cable is used in Siemens Systems.
Typical plugs are RJ45 Industrial IP20 Siemens or Y-Con RJ45 Yamaichi or round M-Connectors from Molex.

Part no. 802471, HMCB200


Dimensions and specifications may be changed without prior notice.
* Drive Cliq is registered trademark from Siemens AG.

724
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
HMCB500S
Drag Chain

Type Drag chain applications


Cable structure 2x2xAWG24 + 1x2xAWG22
Inner conductor diameter 1: Copper, bare (AWG 24/7)
Inner conductor diameter 2: Copper, tinned (AWG 22/19)
Core insulation 1: Foam-skin-PE
Core insulation 2: PE
Core colours 1: gn, ye, pk, bu
Core colours 2: rd, bk
Stranding element 1: Double core
Shielding 1: -
Shielding 2: -
Total shielding: Foil + braid
Outer sheath material: PVC
Cable external diameter: app. 6,95 mm 0,15 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 90 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 180 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Test voltage: 0,5 kV

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (db/100m) 10,0 12,0 23,0 30,0
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 37,0 36,0 12,0 2,0

Technical data
Weight: app. 66 kg/km
bending radius, repeated: 125 mm
Operating temperature range min.: 0C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,00 MJ/m
Copper weight: 38,00 kg/km

Norms
Applicable standards:
UL Style:
Flame-retardant acc. to IEC 60332-1
AWM Style 2502 AWM I/II A/B 80C 30V FT1 R
CSA standard: CSA FT1

Application
HELUKABEL HMCB500S is designed for occasional moving in cable carriers and ranges up to 100m without repeater. This cable is used in Siemens
Systems.
Typical plugs are RJ45 Industrial IP20 Siemens or Y-Con RJ45 Yamaichi or round M-Connectors from Molex.

Part no. 803672, HMCB500S


Dimensions and specifications may be changed without prior notice.
* Drive Cliq is registered trademark from Siemens AG.

725
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
HMCB800
Drag Chain

Type Drag chain applications


Cable structure 2x2x0,20qmm + 1x2x0,38qmm
Inner conductor diameter 1: Copper, bare (AWG 25/19)
Inner conductor diameter 2: Copper, tinned (AWG 22/19)
Core insulation 1: PE
Core insulation 2: PE
Core colours 1: gn, ye, pk, bu
Core colours 2: rd, bk
Stranding element 1: Double core
Shielding 1: -
Shielding 2: -
Total shielding: Foil + braid
Outer sheath material: PUR
Cable external diameter: app. 6,95 mm 0,15 mm
Outer sheath colour: Green similar to RAL 6018

Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 100 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 270 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Test voltage: 0,5 kV

Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (db/100m) 8,0 10,0 20,0 27,0
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 39,0 34,0 15,0 5,0

Technical data
Weight: app. 61 kg/km
bending radius, repeated: 75 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,90 MJ/m
Copper weight: 40,00 kg/km

Norms
Applicable standards: Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
UL Style: AWM Style 20236 AWM I/II A/B 80C 30V FT1
CSA standard: CSA FT1

Application
HELUKABEL HMCB800W is designed for the most demanding continous moving requirements in cable carriers and ranges up to 70 m without
repeater. This cable is ideal solution in Siemens systems.
Typical plugs are RJ45 Industrial IP20 Siemens or Y-Con RJ45 Yamaichi or round M-Connectors from Molex.

Part no. 804767, HMCB800


Dimensions and specifications may be changed without prior notice.

726
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
USB Bus S
Drag Chain

Type Drag chain applications


Cable structure 1x2xAWG28 + 1x2xAWG20
Inner conductor diameter 1: Copper, tinned (AWG 28/19)
Inner conductor diameter 2: Copper, tinned (AWG 20/64)
Core insulation 1: PP
Core insulation 2: PP
Core colours 1: wh, gn
Core colours 2: rd, bk
Stranding element 1: 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle
Shielding 2: -
Total shielding: Foil + braid
Outer sheath material: PUR
Cable external diameter: app. 5,0 mm 0,2 mm
Outer sheath colour: Violet similar to RAL 4001

Electrical data
Characteristic impedance: 90 Ohm 15 %
Conductor resistance, max.: 230 Ohm/km
Insulation resistance, min.: 0,1 GOhm x km
Loop resistance: 460 Ohm/km max.
Mutual capacitance: 60 nF/km nom.
Test voltage: 0,5 kV

Typical values
Frequency (MHz) 10 16 62,5 100 200 300 400
Attenuation (db/100m) 10,1 15,4 31,0 39,7 60,2 76,2 99,7

Technical data
Weight: app. 45 kg/km
bending radius, repeated: 50 mm
Operating temperature range min.: -30C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,55 MJ/m
Copper weight: 30,00 kg/km

Norms
Applicable standards: USB-Standard 2.0
Halogen-free acc. to 60754-2

UL Style:
Flame-retardant CSA FT1
AWM 20963 (80C/30V) R
CSA standard: CSA FT1

Application
HELUKABEL USB BUS S is designed for continous moving in cable carriers and lengths up to max. 5m. Conventional USB cables fail within a short
period of time, which is why HELUKABEL developed this special cable. Thanks to the PU sheath, it also offers excellent resistance to common mineral
oils, greases and cooling lubricants.

Part no. 802469, USB S


Dimensions and specifications may be changed without prior notice.

727
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
USB Bus L
Drag Chain

Type Drag chain applications


Cable structure 1x2xAWG24 + 1x2xAWG20
Inner conductor diameter 1: Copper, tinned (AWG 24/19)
Inner conductor diameter 2: Copper, tinned (AWG 20/19)
Core insulation 1: PO
Core insulation 2: PVC
Core colours 1: wh, gn
Core colours 2: rd, bk
Stranding element 1: Double core
Shielding 1: -
Shielding 2: -
Total shielding: Foil + braid
Drain wire: yes
Outer sheath material: PUR
Cable external diameter: app. 6,3 mm 0,2 mm
Outer sheath colour: Violet similar to RAL 4001

Electrical data
Characteristic impedance: 90 Ohm 15 %
Conductor resistance, max.: 36 Ohm/km
Insulation resistance, min.: 0,2 GOhm x km
Loop resistance: 71 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Nominal voltage: 300 V
Test voltage: 2 kV

Typical values
Frequency (MHz) 1 24 48 96 200 400
Attenuation (db/100m) 4,0 19,0 27,0 38,0 64,0 116,0

Technical data
Weight: app. 56 kg/km
bending radius, repeated: 95 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Caloric load, approx. value: 0,57 MJ/m
Copper weight: 40,00 kg/km

Norms
Applicable standards: USB-Standard 2.0
Flame-retardant acc. to IEC 60332-1
UL Style: AWM 21198 (80C/ 300V)

Application
HELUKABEL USB BUS L is designed for continous motion in cable carriers and lengths up to max. 10m without a repeater. Conventional USB cables
fail within a short period of time and need a repeater after a cable length of 5m, which is why HELUKABEL developed this special cable with a larger
cross-section. Thanks to the PU sheath, it also offers excellent resistance to common mineral oils, greases and cooling lubricants.

Part no. 802470, USB L


Dimensions and specifications may be changed without prior notice.

728
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
USB Bus 3.0
Drag Chain

Type Drag chain applications


Cable structure 2x2xAWG28 + 2x(1x2xAWG28)
Inner conductor diameter 1: Copper, tinned (AWG 28/19)
Inner conductor diameter 2: Copper, tinned (AWG 28/19)
Core insulation 1: Foam-skin-PE
Core insulation 2: PE
Core colours 1: bu/ye, or/vio
Core colours 2: rd/bk, gn/gnwh
Stranding element 1: Double core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: Foil + braid
Total shielding: Cu braid, tinned
Outer sheath material: PUR
Cable external diameter: app. 6,5 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001

Electrical data
Characteristic impedance: 90 Ohm 20 %
105 Ohm 15% at 1 MHz
Conductor resistance, max.: 205 Ohm/km
Insulation resistance, min.: 2 GOhm x km
Loop resistance: 410 Ohm/km max.
Mutual capacitance: 60 nF/km nom.
Test voltage: 0,7 kV
Relative propagation velocity: 75 %

Typical values
Frequency (MHz) 1 625 1200
Attenuation (db/100m) 4,0 115 180

Technical data
Weight: app. 62 kg/km
bending radius, repeated: 55 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Caloric load, approx. value: 0,69 MJ/m
Copper weight: 42,00 kg/km

Norms
Applicable standards: USB-Standard 3.0
Halogen-free acc. to 60754-2 R
Flame-retardant acc. to IEC 60332-1
UL Style: AWM Style 20236 AWM I/II A/B 80C 30V FT1
CSA standard: CSA FT1

Application
HELUKABEL USB S 3.0, designed specifically for use in heavy-duty industries, are the ideal solution for highly-flexible applications such as drag chains
and camera technology. They guarantee superior transmission properties. The transmission distance is connected with the transmission rate.

Part no. 805287, USB S


Dimensions and specifications may be changed without prior notice.

729
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
Coax 50 Ohm, PUR
Drag Chain

Cable structure 19x0,18/ 2,95mm 50 Ohm


Inner conductor material: Copper, bare
Inner conductor diameter: 0.9 mm
Outer conductor material: Copper, tinned
Outer conductor form: Screening
Dialektrikum: PP
Total shielding: Cu braid, vz
Sheat material: PUR (Polyurethan)
External diameter: app. 5,4 mm 0,2 mm
Sheat colour: black

Electrical data
Characteristic impedance: 50 Ohm 2 Ohm
Conductor resistance, max.: 38 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Test voltage: 2 kV
Relative propagation velocity: 67 %

Typical values
Frequency (MHz) 50 100 200 300 500 800 900 1000 1800 2000
Attenuation (db/100m) 11,5 16,5 24,0 30,0 40,0 52,0 59,0 65,0 105,0 112,0

Technical data
Weight: app. 45 kg/km
bending radius, repeated: 54 mm
Operating temperature range max.: +50C
Laying temperature range min.: -20C
Laying temperature range max.: +50C
Copper weight: 23,00 kg/km

Norms
Applicable standards: Halogen-free acc. to 60754-2

Application
This Coax cable, designed specifically for use in heavy-duty industries, is the ideal solution for highly-flexible applications such as drag chains. It guarantee
superior transmission properties.

Part no. 804299, Coax, Drag Chain


Dimensions and specifications may be changed without prior notice.

730
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
fixed installed

Type Fixed installation, indoor Fixed installation, indoor


Cable structure 1x2x0.22 mm (stranded) 4x1x0.22 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 24/7) Copper, bare (AWG 24/7)
Core insulation: Cell PE Cell PE
Core colours: wh/bn wh, bn, gn, ye
Stranding element: Double core Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PVC
Cable external diameter: app. 5,4 mm 0,2 mm app. 6,9 mm 0,2 mm
Outer sheath colour: Violet similar to RAL 4001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 88 Ohm/km 88 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 175 Ohm/km max. 175 Ohm/km max.
Mutual capacitance: 58 nF/km nom. 58 nF/km nom.
Nominal voltage: 30 V 30 V
Test voltage: 1,5 kV 1,5 kV

Technical data
Weight: app. 41 kg/km app. 60 kg/km
bending radius, repeated: 81 mm 107 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,574 MJ/m 1,234 MJ/m
Copper weight: 17,00 kg/km 21,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571 UL Style 2571

Application
HELUKABEL CAN Bus for fixed installation and occasional motion, for normal requirements. The 2-pair version is designed with star-quad twisting,
i.e. diagonal conductors form an electrial pair and satisfy the requirements of the CAN Standard. For cable lengths up to max. 40m (observe CAN
specifications).

Part no. 81286, CAN BUS 81287, CAN BUS R


Dimensions and specifications may be changed without prior notice.

731
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
fixed installed

Type Fixed installation, indoor


Cable structure 2x2x0.22 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 24/7)
Core insulation: Cell PE
Core colours: wh/bn, gn/ye
Stranding element: 2 cores + 2 fillers stranded together
Shielding 1: Polyester foil over stranded bundle
Shielding 2: -
Total shielding: Cu braid, tinned
Outer sheath material: PVC
Cable external diameter: app. 7,5 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 10 %
Conductor resistance, max.: 87,6 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 175 Ohm/km max.
Mutual capacitance: 40 nF/km nom.
Nominal voltage: 30 V
Test voltage: 1,5 kV

Technical data
Weight: app. 60 kg/km
bending radius, repeated: 113 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,13 MJ/m
Copper weight: 32,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to IEC 60332-1
UL Style: UL Style 2571
CSA standard: CSA FT1

Application
HELUKABEL CAN BUS for fixed installation and occasion motion, for normal requirements. The two signal pairs are provided in the form twisted pais.
As a result, the diameter is somewhat larger than that of 81287. In the event of diameter problems, please see this type. For cable lengths up to max.
40m ( observe CAN specifications).

Part no. 82509, CAN BUS


Dimensions and specifications may be changed without prior notice.

732
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
fixed installed, 105C

Type Industrial Area


Cable structure 2x2xAWG 24/19 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 24/19)
Core insulation: XLPE ray cross-linking
Core colours: wh/bn, gn/ye
Stranding element: Double core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: -
Total shielding: Cu braid, tinned
Outer sheath material: PUR
Cable external diameter: app. 8,4 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 10 %
Conductor resistance, max.: 87,2 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 174 Ohm/km max.
Mutual capacitance: 42 nF/km nom.
Nominal voltage: 600 V
Test voltage: 2,5 kV

Technical data
Weight: app. 80 kg/km
bending radius, repeated: 126 mm
Operating temperature range min.: -40C
Operating temperature range max.: +105C *
Caloric load, approx. value: 1,31 MJ/m
Copper weight: 40,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2
Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
UL Style: UL/CSA 21223 80C, 600V

Application
HELUKABEL CAN Bus for fixed installation up to 105C in difficult industrial environments with demanding temperature requirements thanks to
cross-linking of the conductor insulation. Thanks to use a PU sheath, this version is also halogen-free. For cable lengths up to max. 40m (observe CAN
specifications).
R
Part no. 801982, CAN BUS
Dimensions and specifications may be changed without prior notice.

733
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
fixed installed

Type Fixed installation, indoor Fixed installation, indoor


Cable structure 1x2x0.34 mm (stranded) 4x1x0.34 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 22/7) Copper, bare (AWG 22/7)
Core insulation: Cell PE Cell PE
Core colours: wh/bn wh/bn, gn/ye
Stranding element: Double core Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PVC
Cable external diameter: app. 6,5 mm 0,2 mm app. 8,0 mm 0,2 mm
Outer sheath colour: Violet similar to RAL 4001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 57 Ohm/km 57 Ohm/km
Insulation resistance, min.: 5 GOhm x km 5 GOhm x km
Loop resistance: 114 Ohm/km max. 114 Ohm/km max.
Mutual capacitance: 58 nF/km nom. 40 nF/km nom.
Nominal voltage: 30 V 30 V
Test voltage: 2 kV 2 kV

Technical data
Weight: app. 65 kg/km app. 77 kg/km
bending radius, repeated: 98 mm 120 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,109 MJ/m 1,179 MJ/m
Copper weight: 23,00 kg/km 30,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571 UL Style 2571

Application
HELUKABEL CAN Bus for fixed installation and occasional motion, for normal requirements. The 2-pair version is designed with a star-quad twisting,
i.e. diagonal conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lenghts up to max. 40m (observe CAN
specifications).

Part no. 801572, CAN BUS 801573, CAN BUS


Dimensions and specifications may be changed without prior notice.

734
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
fixed installed

Type Fixed installation, indoor


Cable structure 2x2x0.34 mm (stranded)
Inner conductor : Copper, bare (AWG 22/7)
Core insulation: Foam-skin-PE
Core colours: wh/bn, gn/ye
Stranding element: Double core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: -
Total shielding: Cu braid, tinned
Outer sheath material: PVC
Cable external diameter: app. 8,5 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 10 %
Conductor resistance, max.: 55,4 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 110 Ohm/km max.
Mutual capacitance: 40 nF/km nom.
Nominal voltage: 250 V
Test voltage: 1,5 kV

Technical data
Weight: app. 85 kg/km
bending radius, repeated: 130 mm
Operating temperature range min.: -40C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,32 MJ/m
Copper weight: 46,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to IEC 60332-1
UL Style: CMX 75C (shielded)
CSA standard: CSA FT1

Application
HELUKABEL CAN Bus for fix installations an occasion motion, for normal requirements. The two signal pairs are provided in the form twisted pairs.
As a result, the diameter is somewhat larger than that of 801573. In the event of diameter problems, please see this type. For cable lengths up to
max. 40m (observe CAN specifications).
R
Part no. 803344, CAN BUS
Dimensions and specifications may be changed without prior notice.

735
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
fixed installed

Type Fixed installation, indoor Fixed installation, indoor


Cable structure 1x2x0.50 mm (stranded) 4x1x0.50 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 20/7) Copper, bare (AWG 20/7)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: wh/bn wh, bn, gn, ye
Stranding element: Double core Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PVC
Cable external diameter: app. 7,0 mm 0,2 mm app. 8,5 mm 0,2 mm
Outer sheath colour: Violet similar to RAL 4001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 33 Ohm/km 37 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 66 Ohm/km max. 74 Ohm/km max.
Mutual capacitance: 40 nF/km nom. 44 nF/km nom.
Test voltage: 1,5 kV 1,5 kV

Technical data
Weight: app. 69 kg/km app. 100 kg/km
bending radius, repeated: 100 mm 130 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,09 MJ/m 1,64 MJ/m
Copper weight: 30,00 kg/km 45,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571 UL Style 2571

Application
HELUKABEL CAN Bus for fixed installation and occasion motion, for normal requirements. The 2-pair version is designed with star-quad twisting,
i.e. diagonal conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lengths up to 600m (observe CAN
specifications).

Part no. 800571, CAN BUS 800685, CAN BUS


Dimensions and specifications may be changed without prior notice.

736
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
fixed installed

Type Fixed installation, indoor


Cable structure 2x2x0.50 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 20/7)
Core insulation: Foam-skin-PE
Core colours: wh/bn, gn/ye
Stranding element: Double core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: -
Total shielding: Cu braid, tinned
Outer sheath material: PVC
Cable external diameter: app. 9,6 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 10 %
Conductor resistance, max.: 34,4 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 68 Ohm/km max.
Mutual capacitance: 40 nF/km nom.
Nominal voltage: 250 V
Test voltage: 1,5 kV

Technical data
Weight: app. 116 kg/km
bending radius, repeated: 150 mm
Operating temperature range min.: -40C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,62 MJ/m
Copper weight: 60,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to IEC 60332-1
UL Style: CMX 75C (shielded)
CSA standard: CSA FT1

Application
HELUKABEL CAN Bus for fixed installation and occasion motion, for normal requirements. The two signal pairs are provided in the form twisted pairs.
As a result, the diameter is somewhat larger than that of 800685. In the event of diameter problems, please see this type. For cable lengths up to
600m (observe CAN specifications).
R
Part no. 803722, CAN BUS
Dimensions and specifications may be changed without prior notice.

737
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
direct Burial

Type Direct burial Direct burial


Cable structure 1x2x0.50 mm (stranded) 4x1x0.50 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 20/7) Copper, bare (AWG 20/7)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: wh/bn wh, bn, gn, ye
Stranding element: 2 cores + 2 fillers stranded together Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Inner sheath material: PVC PVC
Shielding 2: - -
Total shielding: Cu braid, tinned Cu braid, tinned
Armouring: PET/PA tape PET/PA tape
Outer sheath material: PE PE
Cable external diameter: app. 9,2 mm 0,4 mm app. 9,7 mm 0,4 mm
Outer sheath colour: Black similar to RAL 9005 Black similar to RAL 9005

Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 37 Ohm/km 36,4 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 74 Ohm/km max. 72 Ohm/km max.
Mutual capacitance: 40 nF/km nom. 44 nF/km nom.
Test voltage: 1,5 kV 1,5 kV

Technical data
Weight: app. 105 kg/km app. 115 kg/km
bending radius, repeated: 150 mm 160 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 2,05 MJ/m 2,18 MJ/m
Copper weight: 33,00 kg/km 45,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2

Application
HELUKABEL CAN Bus Direct Burial is suitable for fixed outdoor installation or direct burial applications. The 2-pair version is designed with star-quad
twisting, i.e. diagonal conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lengths up to 600m (observe
CAN specifications).

Part no. 804268, CAN BUS 804269, CAN BUS


Dimensions and specifications may be changed without prior notice.

738
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
fixed installed

Type Fixed installation, indoor Fixed installation, indoor


Cable structure 1x2x0.75 mm (stranded) 4x1x0.75 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 18/24) Copper, bare (AWG 18/24)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: wh/bn wh, bn, gn, ye
Stranding element: Double core Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PVC PVC
Cable external diameter: app. 8,3 mm 0,3 mm app. 8,8 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 15 % 120 Ohm 15 %
Conductor resistance, max.: 27,5 Ohm/km 27,5 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 55 Ohm/km max. 55 Ohm/km max.
Mutual capacitance: 42 nF/km nom. 42 nF/km nom.
Nominal voltage: 300 V 300 V
Test voltage: 1,5 kV 1,5 kV

Technical data
Weight: app. 101 kg/km app. 112 kg/km
bending radius, repeated: 110 mm 110 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,67 MJ/m 1,76 MJ/m
Copper weight: 40,00 kg/km 58,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: UL Style 2571 UL Style 2571
CSA standard: CSA FT1 CSA FT1

Application
HELUKABEL CAN Bus for fix installation and occasion motion, for normal requirements. The 2-pair version is designed with star-quad twisting, i.e.
diagonal conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lengths over 600m (observe CAN specifications).

Part no. 803383, CAN BUS 803384, CAN BUS R


Dimensions and specifications may be changed without prior notice.

739
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
Drag Chain

Type Drag chain applications Drag chain applications


Cable structure 1x2x0.25 mm (stranded) 4x1x0.25 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 24/19) Copper, bare (AWG 24/19)
Core insulation: PE PE
Core colours: wh/bn wh, bn, gn, ye
Stranding element: Double core Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PUR PUR
Cable external diameter: app. 6,1 mm 0,3 mm app. 6,5 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 74 Ohm/km 85 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 148 Ohm/km max. 170 Ohm/km max.
Mutual capacitance: 50 nF/km nom. 50 nF/km nom.
Test voltage: 1,5 kV 1,5 kV

Technical data
Weight: app. 40 kg/km app. 45 kg/km
bending radius, repeated: 90 mm 95 mm
Operating temperature range min.: -40C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,798 MJ/m 0,943 MJ/m
Copper weight: 18,00 kg/km 25,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2

Application
HELUKABEL CAN Bus is designed for guided continous motion in cable carriers. The 2-pair version is designed with a star-quad twisting, i.e. diagonal
conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lengths up to max. 40m (observe CAN specifications).

Part no. 81911, CAN BUS, highly flexible 81912, CAN BUS, highly flexible
Dimensions and specifications may be changed without prior notice.

740
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CAN Bus
Drag Chain, UL

Type Drag chain applications Drag chain applications


Cable structure 1x2x0.34 mm (stranded) 4x1x0.34 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 22) Copper, bare (AWG 22/43)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: wh/bn wh/bn, gn/ye
Stranding element: 2 cores + 2 fillers stranded together Star quad
Shielding 1: - -
Shielding 2: - -
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: PUR PUR
Cable external diameter: app. 6,9 mm 0,3 mm app. 7,5 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 15 % 120 Ohm 15 %
Conductor resistance, max.: 56 Ohm/km 56 Ohm/km
Insulation resistance, min.: 5 GOhm x km 5 GOhm x km
Loop resistance: 170 Ohm/km max. 170 Ohm/km max.
Mutual capacitance: 40 nF/km nom. 40 nF/km nom.
Nominal voltage: 250 V 250 V
Test voltage: 1,5 kV 1,5 kV

Technical data
Weight: app. 54 kg/km app. 64 kg/km
bending radius, repeated: 105 mm 130 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,20 MJ/m 1,20 MJ/m
Copper weight: 30,00 kg/km 42,00 kg/km

Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: CMX 444 CMX 444

Application
HELUKABEL CAN Bus is designed for guided continous motion in cable carriers. The 2-pair version is designed with star-quad twisting, i.e. diagonal
conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lengths up to max. 40m (observe CAN specifications).

Part no. 802182, CAN BUS, highly flexible 802339, CAN BUS, highly flexible R
Dimensions and specifications may be changed without prior notice.

741
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
I-BUS
fixed installed

Type Fixed installation, indoor Fixed installation, indoor


Cable structure 3x2x0.22 mm 3x2x0.22 mm +
3x1.0 mm
Inner conductor diameter: Copper, bare (AWG 24/7) Copper, bare (AWG 24/7)
Inner conductor diameter 2: - Copper, bare (AWG 17/56)
Core insulation: PE PE
Core insulation 2: - PE
Core colours: wh/bn, gn/rd, ye/gn wh/bn, gn/rd, ye/gn
Core colours 2: - bu, rd, gnye
Stranding element: Double core Double core
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Cu braid, bare Cu braid, bare
Outer sheath material: PVC PVC
Cable external diameter: app. 7,0 mm 0,3 mm app. 8,0 mm 0,3 mm
Outer sheath colour: Pastel turquoise similar to RAL 6034 Pastel turquoise similar to RAL 6034

Electrical data
Characteristic impedance: 100 Ohm 15 Ohm 100 Ohm 15 Ohm
Conductor resistance, max.: 96 Ohm/km 96 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 192 Ohm/km max. 192 Ohm/km max.
Mutual capacitance: 60 nF/km nom. 60 nF/km nom.
Test voltage: 1 kV 1 kV
Attenuation: 256 kHz < 1,5 dB/100m 256 kHz < 1,5 dB/100m
772 kHz < 2,4 dB/100m 772 kHz < 2,4 dB/100m
1 MHz < 2,7 dB/100m 1 MHz < 2,7 dB/100m
4 MHz < 5,2 dB/100m 4 MHz < 5,2 dB/100m
10 MHz < 8,4 dB/100m 10 MHz < 8,4 dB/100m
16 MHz < 11,2 dB/100m 16 MHz < 11,2 dB/100m
20 MHz < 11,9 dB/100m 20 MHz < 11,9 dB/100m

Technical data
Weight: app. 70 kg/km app. 96 kg/km
bending radius, repeated: 110 mm 120 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,20 MJ/m 1,31 MJ/m
Copper weight: 35,00 kg/km 68,00 kg/km

Norms
Applicable standards: interbus specification 2.0, IEC61158 interbus specification 2.0, IEC61158
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571 UL Style 2571

Application
HELUKABEL I-Bus is designed for fixed installation and occasional motion, for normal Interbus installation and as a hybrid cable with integrated
power supply.

Part no. 80778, I-BUS 81202, I-BUS


Dimensions and specifications may be changed without prior notice.

742
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
I-BUS
fixed installed, halogenfree

Type Fixed installation, indoor


Cable structure 3x2x0.22 mm
Inner conductor diameter: Copper, bare (AWG 24/7)
Core insulation: PE
Core colours: wh/bn, gn/rd, ye/gn
Stranding element: Double core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Cu braid, bare
Outer sheath material: PE
Cable external diameter: app. 7,0 mm 0,3 mm
Outer sheath colour: Pastel turquoise similar to RAL 6034

Electrical data
Characteristic impedance: 100 Ohm 15 Ohm
Conductor resistance, max.: 96 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 192 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Test voltage: 1 kV
Attenuation: 256 kHz < 1,5 dB/100m
772 kHz < 2,4 dB/100m
1 MHz < 2,7 dB/100m
4 MHz < 5,2 dB/100m
10 MHz < 8,4 dB/100m
16 MHz < 11,2 dB/100m
20 MHz < 11,9 dB/100m

Technical data
Weight: app. 67 kg/km
bending radius, repeated: 110 mm
Operating temperature range min.: -25C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,10 MJ/m
Copper weight: 35,00 kg/km

Norms
Applicable standards: interbus specification 2.0, IEC61158
Halogen-free acc. to 60754-2

Application R
HELUKABEL I-Bus is halogen-free and designed for fixed installation in buildings in an Interbus network. The cable is used in dry areas where its
halogen-free construction is a major aspect.

Part no. 81557, I-BUS


Dimensions and specifications may be changed without prior notice.

743
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
I-BUS
Drag Chain

Type Drag chain applications Drag chain applications


Cable structure 3x2x0.25 mm 3x2x0.25 mm +
3x1.0 mm
Inner conductor diameter: Copper, bare (AWG 24/19) Copper, bare (AWG 24/19)
Inner conductor diameter 2: - Copper, bare (AWG 17/56)
Core insulation: PE PE
Core insulation 2: - PE
Core colours: wh/bn, gn/rd, ye/gn wh/bn, gn/rd, ye/gn
Core colours 2: - bu, rd, gnye
Stranding element: Double core Double core
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Cu braid, bare Cu braid, bare
Outer sheath material: PUR PUR
Cable external diameter: app. 7,6 mm 0,3 mm app. 8,6 mm 0,3 mm
Outer sheath colour: Pastel turquoise similar to RAL 6034 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 100 Ohm 15 Ohm 100 Ohm 15 Ohm
Conductor resistance, max.: 96 Ohm/km 96 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 192 Ohm/km max. 192 Ohm/km max.
Mutual capacitance: 60 nF/km nom. 60 nF/km nom.
Test voltage: 1 kV 1 kV
Attenuation: 256 kHz < 1,5 dB/100m 256 kHz < 1,5 dB/100m
772 kHz < 2,4 dB/100m 772 kHz < 2,4 dB/100m
1 MHz < 2,7 dB/100m 1 MHz < 2,7 dB/100m
4 MHz < 5,2 dB/100m 4 MHz < 5,2 dB/100m
10 MHz < 8,4 dB/100m 10 MHz < 8,4 dB/100m
16 MHz < 11,2 dB/100m 16 MHz < 11,2 dB/100m
20 MHz < 11,9 dB/100m 20 MHz < 11,90 dB/100m

Technical data
Weight: app. 63 kg/km app. 92 kg/km
bending radius, repeated: 120 mm 130 mm
Operating temperature range min.: -20C -20C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,937 MJ/m 1,227 MJ/m
Copper weight: 36,00 kg/km 70,00 kg/km

Norms
Applicable standards: interbus specification 2.0, IEC61158 interbus specification 2.0, IEC61158
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to EN 50265-2-1

Application
HELUKABEL I-Bus is designed for guided continuous motion in cable carriers and as strictly a bus cable or a hybrid version (with integrated power
supply). Both versions feature a halogen-free PU jacket.

Part no. 81203, I-BUS 82696, I-BUS


Dimensions and specifications may be changed without prior notice.

744
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS-Cables
Multibus I, high flexible

Type Multibus I, 15 cores high flexible


Cable structure
Profibus: 1 x 2 x AWG 22 mm2 (Foam-Skin PO/rd/gn)
DeviceNetTM: 2 x 2 x AWG 22 mm2 (Foam-Skin PO/wh/bn, ye/gn)
Interbus: 2 x 2 x 0,25 (Foam-Skin PO/ gn/pk, ye/gn)
Power cores: 4 x 1 x 1,0 mm2 (PO/rd, bl, bu, bn)
Protective earth core: 1,0 mm2 (PO/gnye)
Stranding: Single cores totaly stranded together and filled with plastic elements
Total shielding: PP vlies
Outer sheath material: PUR, halogenfree
Cable external diameter: app. 14,7 mm
Outer sheath colour: violet similar to RAL 4001

Electrical data
Characteristic impedance: 150 + -15 Ohm (Profibus)
120 + -12 Ohm (DeviceNetTM)
100 + -15 Ohm (Interbus)
Conductor resistance: <= 20 Ohm/km (power cores + protection core)
<= 70 Ohm/km (Profibus)
<= 70 Ohm/km (DeviceNetTM)
<= 80 Ohm/km (Interbus)
Insulation resistance: >= 500 Mohm x km (at 20 C)
Mutual capacitance: 30 pF/m nominal (Profibus)
40 pF/m nominal (DeviceNetTM)
50 pF/m nominal (Interbus)
Testvoltage: 2500 V (core/ core)
1500 V (core/ screen)

Mechanical data
Bending radius single: <= 70 mm
Bending radius repeated: <= 110 mm
Tensile strength static: 300 N
Tensile strength dynamic: 140 N
Oil resistance: Diesel, IRM 902, Biohydran TM68, Ecocut HFN 10LE
Flame resistance: IEC 60332-1, VW1/ FT1 acc. C-UL
FCKW free: yes
Self extinguishable: yes R
Other attributes: PVC free, free of lacquer wetting disturbing substances, siliconfree,
resistant against PVC flexibiliser and cable fat RB1

Thermal attributes
Operating temperature range: - 40 C to + 80 C
Laying temperature range: - 30 C to + 80 C

Norms Profibus standard, DeviceNetTM standard, Interbus standard

UL-Style VW1/ FT1 acc. C-UL, AWM style 20236

Application HELUKABEL Multibus I is highly flexible with a special structure for use in cable carrier
applications and robotics (use in acc. with HELU specification) in a PVC-free design.
The Multibus I combines the Profibus / DeviceNet / Interbus bus systems as well as
the power supply in a single hybrid cable.

Part no. 801652, Multibus I, 15 cores

745
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS-Cables
Multibus II, high flexible

Type Multibus II, 15 cores high flexible


Cable structure
Profibus: 1 x 2 x 0,34 mm2 (Foam-Skin PO/rd/gn)
DeviceNetTM: 4 x 2 x 0,34 mm2 (Foam-Skin PE/ye, or, wh, bu-ye, or, wh, bu)
Power cores 1: 2 x 1,0 mm2 (PO/rd, bl)
Power cores 2: 2 x 1,5 mm2 (PO/bu, bn)
Protective earth core: 1,5 mm2 (PO/gnye)
Stranding: Single cores totaly stranded together and filled with plastic elements
Total shielding: PP vlies
Outer sheath material: PUR, halogenfree
Cable external diameter: app. 15,0 mm
Outer sheath colour: violet similar to RAL 4001

Electrical data
Characteristic impedance: 150 + -15 Ohm (Profibus)
100 + -15 Ohm (PROFInet)
Conductor resistance: <= 20 Ohm/km (power cores + protection core)
<= 70 Ohm/km (Profibus)
<= 62 Ohm/km (PROFInet)
Insulation resistance: >= 500 Mohm x km (at 20 C)
Mutual capacitance: 30 pF/m nominal (Profibus)
40 pF/m nominal (PROFInet)
Testvoltage: 2500 V (core/ core)
1500 V (core/ screen)

Mechanical data
Bending radius single: <= 70 mm
Bending radius repeated: <= 110 mm
Tensile strength static: 300 N
Tensile strength dynamic: 140 N
Oil resistance: Diesel, IRM 902, Biohydran TM68, Ecocut HFN 10LE
Flame resistance: IEC 60332-1, VW1/ FT1 acc. C-UL
FCKW free: yes
Self extinguishable: yes
Other attributes: PVC free, free of lacquer wetting disturbing substances, siliconfree,
resistant against PVC flexibiliser and cable fat RB1

Thermal attributes
Operating temperature range: - 40 C to + 80 C
Laying temperature range: - 20 C to + 80 C

Norms Profibus standard, PROFInet standard


UL-Style VW1/ FT1 acc. C-UL, AWM style 20236
Application HELUKABEL Multibus II is highly flexible with a special structure for use in cable carrier
applications and robotics (use in acc. with HELU specification) in a PVC-free design.
The Multibus II (further development of Multibus I) combines the Profibus /Profinet
bus systems as well as the power supply in a single hybrid cable.
Part no. 804115, Multibus II, 15 cores

746
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
A-BUS
EPDM

Type Actuator Sensor Interface Actuator Sensor Interface


Cable structure 2x1.5 mm 2x1.5 mm
Inner conductor: Copper, tinned Copper, tinned
Core insulation: Rubber compound Rubber compound
Core colours: bu, bn bu, bn
Shielding 1: - -
Shielding 2: - -
Total shielding: - -
Outer sheath material: EPDM EPDM
Outer sheath colour: Yellow similar to RAL 1023 Black similar to RAL 9005

Electrical data
Conductor resistance, max.: 13,7 Ohm/km 13,7 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 27 Ohm/km max. 27 Ohm/km max.
Nominal voltage: 32 V 48 V
Test voltage: 1 kV at 15 min. 1 kV at 15 min.

Technical data
Weight: app. 70 kg/km app. 70 kg/km
bending radius, repeated: 30 mm 30 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +85C +85C
Caloric load, approx. value: 0,975 MJ/m 0,975 MJ/m
Copper weight: 31,00 kg/km 31,00 kg/km

Norms
Applicable standards: ASI standard ASI standard
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2

Application
HELUKABEL A-Bus EPDM Rubber for normal use in an AS-I system. Applications include wet/dry areas where the properties of a rubber jacket are
desired. In addition, this material offers benefits such as low compression forces needed when contacting and the best sealing against the AS-I module.

Part no. 80824, A-BUS EPDM 80825, A-BUS EPDM


Dimensions and specifications may be changed without prior notice.

747
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
A-BUS EPDM, Long Distance

Type Industrial Area Industrial Area


Cable structure 2x2.5 mm 2x2.5 mm
Inner conductor: Copper, tinned Copper, tinned
Core insulation: Rubber compound Rubber compound
Core colours: bu, bn bu, bn
Shielding 1: - -
Shielding 2: - -
Total shielding: - -
Outer sheath material: EPDM EPDM
Outer sheath colour: Yellow similar to RAL 1023 Black similar to RAL 9005

Electrical data
Technical data
Weight: app. 130 kg/km app. 130 kg/km
bending radius, repeated: 35 mm 30 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +85C +85C
Caloric load, approx. value: 0,70 MJ/m 0,70 MJ/m
Copper weight: 49,00 kg/km 49,00 kg/km

Norms
Applicable standards: ASI standard ASI standard
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2

Application
HELUKABEL A-Bus Long Distance EPDM Rubber 2,5mm for normal use in an AS-I system. The enlarged cross-section allows bigger transmission
distances, higher ampacity and this results in savings of supplementary power packs. Applications include wet/dry areas where the properties of a
rubber jacket are desired. In addition, this material offers benefits such as low compression forces needed when contacting and the best sealing against
the AS-I module.

Part no. 804408, A-BUS EPDM 804409, A-BUS EPDM


Dimensions and specifications may be changed without prior notice.

748
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
A-BUS
PUR, UL/CSA

Type Actuator Sensor Interface Actuator Sensor Interface


Cable structure 2x1.5 mm 2x1.5 mm
Inner conductor: Copper, tinned Copper, tinned
Core insulation: PO PO
Core colours: bu, bn bu, bn
Shielding 1: - -
Shielding 2: - -
Total shielding: - -
Outer sheath material: PUR PUR
Outer sheath colour: Yellow similar to RAL 1023 Black similar to RAL 9005

Electrical data
Conductor resistance, max.: 13,7 Ohm/km 13,7 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 27 Ohm/km max. 27 Ohm/km max.
Nominal voltage: 32 V 48 V
Test voltage: 1 kV at 15 min. 1 kV at 15 min.

Technical data
Weight: app. 64 kg/km app. 64 kg/km
bending radius, repeated: 30 mm 30 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 0,965 MJ/m 0,965 MJ/m
Copper weight: 31,00 kg/km 31,00 kg/km

Norms
Applicable standards: ASI standard ASI standard
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: AWM Style 20549 AWM Style 20549
CSA standard: CSA FT2 CSA FT2

Application
HELUKABEL A-Bus PU is ideal for use in wet/dry areas thanks to its outstanding characteristics when exposed to common coolants/lubricants. This
version can also be used in cable carriers (special installation conditions must be observed: place wide cable side on inside radius, use partitions and
install flat/round cables separately). These types are approved for use in the American market (UL 1581, FT2) thanks to use of special materials.

Part no. 82434, A-BUS PUR 82822, A-BUS PUR


Dimensions and specifications may be changed without prior notice.
R

749
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
A-BUS PUR 2X2.5 PUR, Long Distance, UL/CSA

Type Drag chain applications Drag chain applications


Cable structure 2x2.5 mm 2x1.5 mm
Inner conductor: Copper, tinned Copper, tinned
Core insulation: PO PO
Core colours: bu, bn bu, bn
Shielding 1: - -
Shielding 2: - -
Total shielding: - -
Outer sheath material: PUR PUR
Outer sheath colour: Yellow similar to RAL 1023 Black similar to RAL 9005

Electrical data
Conductor resistance, max.: 8,21 Ohm/km 8,21 Ohm/km
Loop resistance: 16 Ohm/km max. 16 Ohm/km max.
Nominal voltage: 32 V 48 V

Technical data
Weight: app. 140 kg/km app. 140 kg/km
bending radius, repeated: 30 mm 30 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 0,90 MJ/m 0,90 MJ/m
Copper weight: 49,00 kg/km 49,00 kg/km

Norms
Applicable standards: ASI standard ASI standard
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant CSA FT2 Flame-retardant CSA FT2
UL Style: AWM Style 20549 AWM Style 20549
CSA standard: CSA FT2 CSA FT2

Application
AS components are interconnected with this special system cable. With the AS interface, the cable assembly from the control system to the sensor/actuator
is not needed. The AS interface is the field bus system that transmitts both data and power in one single cable. With fast contacting in penetration
technique, the possibility of errors in cabling is largely reduced. The special outer jacket provides protection against oil, grease, and refrigerant lubricants,
and the cable is therefore even suitable for applications in wet surroundings, in machinery and plant construction, as well as in the machine tool and
automotive industry. The PUR variant is suitable for heavy-duty industrial environments.
Because of the cross section 2,5qmm it is possible to realize longer distances.
These types are certified for the American market (UL 1581, FT2) through the use of special materials.

Part no. 804410, A-BUS PUR 804411, A-BUS PUR


Dimensions and specifications may be changed without prior notice.

750
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
A-BUS
TPE

Type Actuator Sensor Interface Actuator Sensor Interface


Cable structure 2x1.5 mm 2x1.5 mm
Inner conductor: Copper, tinned Copper, tinned
Core insulation: TPE TPE
Core colours: bu, bn bu, bn
Shielding 1: - -
Shielding 2: - -
Total shielding: - -
Outer sheath material: TPE TPE
Outer sheath colour: Yellow Black

Electrical data
Conductor resistance, max.: 13,7 Ohm/km 13,7 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 27 Ohm/km max. 27 Ohm/km max.
Nominal voltage: 32 V 48 V
Test voltage: 1,5 kV at 15 min. 1,5 kV at 15 min.

Technical data
Weight: app. 70 kg/km app. 70 kg/km
bending radius, repeated: 24 mm 24 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +105C +105C
Caloric load, approx. value: 1,10 MJ/m 1,10 MJ/m
Copper weight: 31,00 kg/km 31,00 kg/km

Norms
Applicable standards: ASI standard ASI standard
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1

Application
HELUKABEL A-Bus TPE for demanding temperature requirements up to 105 C and flame retardance. The special outer sheath makes the cable
resistant to many oils, greases and cooling lubricants and thus suitable for applications in wet surroundings, in machinery and plant construction as
well as the machine tool and automotive industries.

Part no. 801846, A-BUS TPE 801847, A-BUS TPE


Dimensions and specifications may be changed without prior notice.

751
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
AS-Interface
Electrical Cabinet FLIH

Type Fixed installation, indoor


Cable structure 2x0,86/ 2,5
Inner conductor: Copper, tinned
Shielding 1: -
Shielding 2: -
Total shielding: -
Outer sheath material: FRNC
Outer sheath colour: Yellow

Electrical data
Characteristic impedance: 105 Ohm 35 Ohm
Conductor resistance, max.: 23 Ohm/km
Insulation resistance, min.: 0,01 GOhm x km
Loop resistance: 46 Ohm/km max.
Nominal voltage: 300 V
Test voltage: 2 kV at 15 min.

Technical data
Weight: app. 24 kg/km
bending radius, repeated: 30 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Caloric load, approx. value: 0,30 MJ/m
Copper weight: 20,00 kg/km

Norms
Applicable standards: ASI standard
Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
UL Style: UL Style 2444

Application
HELUKABEL AS-Interface FLIH for electrical cabinet applications, especially for wiring inside electrical cabinets. Compared to "normal" AS-I wire, less
space is needed and routing is improved. This cable is also designed for appropriate fast contacting through use of the penetration technique. Special
modules for electrical cabinets that are compatible with this wire are available on the market.

Part no. 802183, AS-Interface FLIH


Dimensions and specifications may be changed without prior notice.

752
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
DeviceNet
PVC

Type Fixed installation, indoor Fixed installation, indoor


Cable structure 1x2xAWG18 + 1x2xAWG24 +
1x2xAWG15 1x2xAWG22
Inner conductor diameter 1: Copper, tinned (AWG 18/19) Copper, tinned (AWG 24/19)
Inner conductor diameter 2: Copper, tinned (AWG 15/19) Copper, tinned (AWG 22/19)
Core insulation 1: Foam-skin-PE Foam-skin-PE
Core insulation 2: PVC PVC
Core colours 1: light bu, wh light bu, wh
Core colours 2: rd, bk rd, bk
Stranding element 1: Double core Double core
Shielding 1: - -
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Copper shifting, tinned
Drain wire: yes yes
Outer sheath material: PVC PVC
Cable external diameter: app. 12,2 mm 0,3 mm app. 6,9 mm 0,3 mm
Outer sheath colour: Grey Grey

Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 22,6 Ohm/km 90 Ohm/km
Insulation resistance, min.: 0,2 GOhm x km 0,2 GOhm x km
Loop resistance: 45 Ohm/km max. 180 Ohm/km max.
Mutual capacitance: 39,8 nF/km nom. 39,8 nF/km nom.
Test voltage: 2 kV 2 kV
Attenuation: 125 kHz < 0,42 dB/100m 125 kHz < 0.95 dB/100m
500 kHz < 0,81 dB/100m 500 kHz < 1.64 dB/100m

Technical data
Weight: app. 192 kg/km app. 67 kg/km
bending radius, repeated: 190 mm 110 mm
Operating temperature range min.: -20C -20C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 2,92 MJ/m 0,91 MJ/m
Copper weight: 88,00 kg/km 35,00 kg/km

Norms
Applicable standards: ODVA DeviceNet ODVA DeviceNet
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style:
CSA standard:
CMG 75C PLTC FT4
CEC: CMG FT4
CMG 75C PLTC FT4
CSA FT 4
R
Application
HELUKABEL DeviceNet PVC for fixed installation. The special aspect of this bus system is that a data pair and a power supply pair are always
integrated in one cable. The small cross-section is used for short distances or as a point-to-point connection; the large cross-section as main conductor
for long distances and frequently in combination with the thin conductor as drain wire.

Part no. 800683, DeviceNet PVC 800684, DeviceNet PVC


Dimensions and specifications may be changed without prior notice.

753
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
DeviceNet
FRNC

Type Fixed installation, indoor Fixed installation, indoor


Cable structure 1x2xAWG18 + 1x2xAWG24 +
1x2xAWG15 1x2xAWG22
Inner conductor diameter 1: Copper, tinned (AWG 18/19) Copper, tinned (AWG 24/19)
Inner conductor diameter 2: Copper, tinned (AWG 15/19) Copper, tinned (AWG 22/19)
Core insulation 1: Cell PE Cell PE
Core insulation 2: PE PE
Core colours 1: light bu, wh light bu, wh
Core colours 2: rd, bk rd, bk
Stranding element 1: Double core Double core
Shielding 1: - -
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Drain wire: yes yes
Outer sheath material: FRNC FRNC
Cable external diameter: app. 12,2 mm 0,3 mm app. 6,9 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 22,6 Ohm/km 90 Ohm/km
Insulation resistance, min.: 0,2 GOhm x km 0,2 GOhm x km
Loop resistance: 45 Ohm/km max. 180 Ohm/km max.
Mutual capacitance: 39 nF/km nom. 39,8 nF/km nom.
Test voltage: 2 kV 2 kV
Attenuation: 125 kHz < 0.42 dB/100m 125 kHz < 0.95 dB/100m
500 kHz < 0.81 dB/100m 500 kHz < 1.64 dB/100m

Technical data
Weight: app. 195 kg/km app. 70 kg/km
bending radius, repeated: 190 mm 110 mm
Operating temperature range min.: -25C -25C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 2,73 MJ/m 0,82 MJ/m
Copper weight: 88,00 kg/km 34,00 kg/km

Norms
Applicable standards: ODVA DeviceNet ODVA DeviceNet
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: CL2 CMG CL2 CMG
CSA standard: CEC: CMG FT4 CEC: CMG FT4

Application
HELUKABEL DeviceNet FRNC for fixed installation in areas where high flame retardance and a halogen-free design are needed. The special aspect
of this bus system is that a data pair and a power supply pair are always integrated in one cable. The small cross-section is used for short distances
or as a point-to-point connection; the large cross-section as main conductor for long distances and frequently in combination with the thin conductor
as drain wire.

Part no. 800681, DeviceNet FRNC 800682, DeviceNet FRNC


Dimensions and specifications may be changed without prior notice.

754
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
DeviceNet
CPE

Type Fixed installation, indoor Fixed installation, indoor


Cable structure 1x2xAWG18 + 1x2xAWG24 +
1x2xAWG15 1x2xAWG22
Inner conductor diameter 1: Copper, tinned (AWG 18/19) Copper, tinned (AWG 24/19)
Inner conductor diameter 2: Copper, tinned (AWG 15/19) Copper, tinned (AWG 22/19)
Core insulation 1: Cell PE PE
Core insulation 2: PE PVC
Core colours 1: light bu, wh light bu, wh
Core colours 2: rd, bk rd, bk
Stranding element 1: Double core Double core
Shielding 1: - -
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Drain wire: yes yes
Outer sheath material: CPE CPE
Cable external diameter: app. 12,0 mm 0,3 mm app. 7,0 mm 0,3 mm
Outer sheath colour: Yellow Yellow

Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 22,6 Ohm/km 90 Ohm/km
Insulation resistance, min.: 0,2 GOhm x km 0,2 GOhm x km
Loop resistance: 45 Ohm/km max. 180 Ohm/km max.
Mutual capacitance: 39 nF/km nom. 39 nF/km nom.
Test voltage: 2 kV 2 kV
Attenuation: 125 kHz < 0,43 dB/100m 125 kHz < 0,95 dB/100m
500 kHz < 0,82 dB/100m 500 kHz < 1,64 dB/100m

Technical data
Weight: app. 195 kg/km app. 70 kg/km
bending radius, repeated: 190 mm 110 mm
Operating temperature range min.: -20C -20C
Operating temperature range max.: +60C +60C
Caloric load, approx. value: 2,73 MJ/m 0,82 MJ/m
Copper weight: 71,20 kg/km 28,10 kg/km

Norms
Applicable standards: ODVA DeviceNet ODVA DeviceNet
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style:
CSA standard:
CMG PLTC
CEC: CMG FT4
CL2 CMG
CEC: CMG FT4
R
Application
HELUKABEL DeviceNet CPE for fixed installation with very high flame-retardance requirements. The special aspect of this bus system is that a data
pair and a power supply pair are always integrated in one cable. The small cross-section is used for short distances or as a point-to-point connection;
the large cross-section as main conductor for long distances and frequently in combination with the thin conductor as drain wire.

Part no. 81907, DeviceNet CPE 81908, DeviceNet CPE


Dimensions and specifications may be changed without prior notice.

755
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
DeviceNet
PUR, high flexible

Type Drag chain applications Drag chain applications


Cable structure 1x2xAWG18 + 1x2xAWG24 +
1x2xAWG15 1x2xAWG22
Inner conductor diameter 1: Copper, tinned (AWG 18/40) Copper, tinned (AWG 24/19)
Inner conductor diameter 2: Copper, tinned (AWG 15/84) Copper, tinned (AWG 22/19)
Core insulation 1: Cell PE Cell PE
Core insulation 2: PE PE
Core colours 1: light bu, wh light bu, wh
Core colours 2: rd, bk rd, bk
Stranding element 1: Double core Double core
Shielding 1: - -
Shielding 2: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned Cu braid, tinned
Drain wire: yes yes
Outer sheath material: PUR PUR
Cable external diameter: app. 12,2 mm 0,3 mm app. 6,9 mm 0,3 mm
Outer sheath colour: Violet similar to RAL 4001 Violet similar to RAL 4001

Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 22,6 Ohm/km 90 Ohm/km
Insulation resistance, min.: 0,2 GOhm x km 0,2 GOhm x km
Loop resistance: 45 Ohm/km max. 45 Ohm/km max.
Mutual capacitance: 39,8 nF/km nom. 39,8 nF/km nom.
Test voltage: 2 kV 2 kV
Attenuation: 125 kHz < 0,41 dB/100m 125 kHz < 0,95 dB/100m
500 kHz < 0,82 dB/100m 500 kHz < 1,64 dB/100m

Technical data
Weight: app. 185 kg/km app. 68 kg/km
bending radius, repeated: 61 mm 70 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 2,54 MJ/m 0,76 MJ/m
Copper weight: 90,00 kg/km 35,00 kg/km

Norms
Applicable standards: ODVA DeviceNet ODVA DeviceNet
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: CMX 75C CL2X CMX 75C CL2X

Application
HELUKABEL DeviceNet PU highly flexible for use in cable carriers with outstanding resistance to common coolants/lubricants. The special aspect
of this bus system is that a data pair and a power supply pair are always integrated in one cable. The small cross-section is used for short distances
or as a point-to- point connection; the large cross-section as main conductor for long distances and frequently in combination with the thin conductor
as drain wire.

Part no. 81909, DeviceNet PUR 81910, DeviceNet PUR


Dimensions and specifications may be changed without prior notice.

756
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
CC-Link BUS
PVC

Type Fixed installation, indoor


Cable structure 3x0.5 mm
Inner conductor diameter: Copper, bare (AWG 20/7)
Core insulation: Foam-skin-PE
Core colours: wh, bu, ye
Stranding element: Triple core
Shielding 1: Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned
Drain wire: yes
Outer sheath material: PVC
Cable external diameter: app. 7,7 mm 0,3 mm
Outer sheath colour: Red

Electrical data
Characteristic impedance: 110 Ohm 15 Ohm
Conductor resistance, max.: 37,8 Ohm/km
Insulation resistance, min.: 10 GOhm x km
Loop resistance: 75 Ohm/km max.
Mutual capacitance: 60 nF/km nom.
Test voltage: 2 kV
Attenuation: 1 MHz < 16,0 dB/100m
5 MHz < 35,0 dB/100m

Technical data
Weight: app. 77 kg/km
bending radius, repeated: 120 mm
Operating temperature range min.: -40C
Operating temperature range max.: +75C
Caloric load, approx. value: 1,10 MJ/m
Copper weight: 40,00 kg/km

Norms
Applicable standards: CC-Link Specification 1.10
Flame-retardant acc. to EN 50265-2-1
UL Style: CM 75C or PLTC
CSA standard: CSA FT 4

Application
HELUKABEL CC-Link Bus PVC for fixed installation. The primary market is Asia, but the USA and the United Kingdom are using CC-Link increasingly.
The cable has the appropriate approvals for these markets. A version with power supply conductors is optionally available. It is used particularly in R
channels.

Part no. 800497, CC-Link communications cable


Dimensions and specifications may be changed without prior notice.

757
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
SafetyBUS
FRNC + PUR

Type Fixed installation, indoor Drag chain applications


Cable structure 3x0,75 mm (stranded) 3x0,75 mm (stranded)
Inner conductor diameter: Copper, bare (AWG 18/24) Copper, bare (AWG 18)
Core insulation: Foam-skin-PE Foam-skin-PE
Core colours: wh, bn, gn wh, bn, gn
Stranding element: Triple core Triple core
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Cu braid, tinned Cu braid, tinned
Outer sheath material: FRNC PUR
Cable external diameter: app. 7,5 mm 0,3 mm app. 7,8 mm 0,2 mm
Outer sheath colour: Yellow similar to RAL 1003 Yellow similar to RAL 1003

Electrical data
Characteristic impedance: 110 Ohm 10 Ohm 110 Ohm 10 Ohm
Conductor resistance, max.: 27,7 Ohm/km 26 Ohm/km
Insulation resistance, min.: 5 GOhm x km 5 GOhm x km
Loop resistance: 52 Ohm/km max. 52 Ohm/km max.
Mutual capacitance: 45 nF/km nom. 45 nF/km nom.
Nominal voltage: 250 V 250 V
Test voltage: 3 kV 3 kV
Attenuation: 1 MHz < 1,6 dB/Km 1 MHz < 1,6 dB/Km
5 MHz < 3,4 dB/Km 5 MHz < 3,4 dB/Km
10 MHz < 5,6 dB/Km 10 MHz < 5,6 dB/Km
16 MHz < 7,5 dB/Km 16 MHz < 7,5 dB/Km

Technical data
Weight: app. 68 kg/km app. 65 kg/km
bending radius, repeated: 75 mm 80 mm
Operating temperature range min.: -25C -30C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 0,72 MJ/m 0,76 MJ/m
Copper weight: 50,00 kg/km 50,00 kg/km

Norms
Applicable standards: abutted at SafetyBUS p technical guidelines abutted at SafetyBUS p technical guidelines
copper wires 1.0 copper wires 1.0
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-3 Flame-retardant acc. to IEC 60332-1
UL Style: - CMX 75C (shielded)

Application
HELUKABEL SafetyBUS FRNC for fixed installation; the PU version is intended for use in cable carriers. Both versions are halogen-free.

Part no. 800651, SafetyBus p 800652, SafetyBus p


Dimensions and specifications may be changed without prior notice.

758
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
LON BUS
H122 + Y116

Type Fixed installation, indoor Mobile use


Cable structure 1x2xAWG 22/1 1x2xAWG 16/19
Inner conductor diameter: Copper, tinned (AWG 22/1) Copper, tinned (AWG 16/19)
Core insulation: PE PVC
Core colours: wh, bu wh, bk
Stranding element: Double core Double core
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Polyester foil, aluminium-lined -
Drain wire: yes -
Outer sheath material: FRNC PVC
Cable external diameter: app. 4,4 mm 0,3 mm app. 7,0 mm 0,4 mm
Outer sheath colour: White Grey

Electrical data
Characteristic impedance: 100 Ohm 10 % 85 Ohm 15 %
Conductor resistance, max.: 57 Ohm/km 15,8 Ohm/km
Insulation resistance, min.: 5 GOhm x km 0,02 GOhm x km
Loop resistance: 114 Ohm/km max. 31 Ohm/km max.
Mutual capacitance: 45 nF/km nom. 10 nF/km nom.
Nominal voltage: 125 V 300 V
Test voltage: 0,7 kV 2 kV

Technical data
Weight: app. 25 kg/km app. 65 kg/km
bending radius, repeated: 70 mm 85 mm
Operating temperature range min.: -20C -20C
Operating temperature range max.: +75C +80C
Caloric load, approx. value: 0,337 MJ/m 1,25 MJ/m
Copper weight: 11,00 kg/km 30,00 kg/km
Applicable standards: Halogen-free acc. to 60754-2 Flame-retardant acc. to IEC 60332-1
Flame-retardant acc. to IEC 60332-1

Application
HELUKABEL LON BUS H122 FRNC for fixed installation; version Y116 for mobile applications. For both versions: Use indoors is in fixed installations
(H122) and as a patch cable (Y116) and must comply with DIN EN 50090-2-2 (VDE 0892 Part 2-2:1997-06).

Part no. 802187, LON H122 802188, LON Y116


Dimensions and specifications may be changed without prior notice.

759
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
E-BUS
PVC

Type 2-pairs 2-pairs


Cable structure 2x2x0.8 mm 2x2x0.8 mm
Inner conductor: Copper, bare Copper, bare
Core insulation: PVC PVC
Core colours: wh, ye, rd, bk wh, ye, rd, bk
Stranding element: Star quad Star quad
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Drain wire: yes yes
Outer sheath material: PVC PVC
Cable external diameter: app. 6,6 mm 0,3 mm app. 6,6 mm 0,3 mm
Outer sheath colour: Blue Lilac similar to RAL 4005 Green similar to RAL 6010

Electrical data
Characteristic impedance: 100 Ohm 100 Ohm
Conductor resistance, max.: 73,2 Ohm/km 73,2 Ohm/km
Insulation resistance, min.: 0,1 GOhm x km 0,1 GOhm x km
Loop resistance: 146 Ohm/km max. 146 Ohm/km max.
Mutual capacitance: 100 nF/km nom. 100 nF/km nom.
Test voltage: 4 kV 4 kV

Technical data
Weight: app. 64 kg/km app. 64 kg/km
bending radius, repeated: 95 mm 95 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,90 MJ/m 0,90 MJ/m
Copper weight: 25,00 kg/km 25,00 kg/km

Norms
Applicable standards: EIB standard EIB standard
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1

Application
HELUKABEL E-BUS PVC for fixed installation. The E-Bus cable is intended for transmission of bus signals in intelligent building systems. The cables
ensure perfect communication in compliance with EIB regulations. They can be installed over, in and under plaster, in conduits and cable channels, in
dry, damp and wet rooms as well as outdoors - if protected from direct sunlight. Wiring together with high-power cables is possible without limitation.
The EIB bus can be used to control lighting, blinds, heating, ventilation, indicator boards etc.

Part no. 81081, E-BUS 81663, E-BUS


Dimensions and specifications may be changed without prior notice.

760
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
E-BUS
FRNC + PVC

Type 2-pairs 4-pairs


Cable structure 2x2x0.8 mm 4x2x0.8 mm
Inner conductor: Copper, bare Copper, bare
Core insulation: PE PVC
Core colours: wh, ye, rd, bk wh, ye, rd, gn, bu, bn, wh, wh
Stranding element: Star quad Double core
Shielding 1: Polyester foil over stranded bundle Polyester foil over stranded bundle
Shielding 2: - -
Total shielding: Polyester foil, aluminium-lined Polyester foil, aluminium-lined
Drain wire: yes yes
Outer sheath material: FRNC PVC
Cable external diameter: app. 6,6 mm 0,3 mm app. 8,2 mm 0,4 mm
Outer sheath colour: Blue Lilac similar to RAL 4005 Blue Lilac similar to RAL 4005

Electrical data
Characteristic impedance: 100 Ohm 100 Ohm
Conductor resistance, max.: 73,2 Ohm/km 73,2 Ohm/km
Insulation resistance, min.: 0,1 GOhm x km 0,1 GOhm x km
Loop resistance: 146 Ohm/km max. 146 Ohm/km max.
Mutual capacitance: 100 nF/km nom. 100 nF/km nom.
Test voltage: 4 kV 4 kV

Technical data
Weight: app. 54 kg/km app. 92 kg/km
bending radius, repeated: 95 mm 120 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,58 MJ/m 1,37 MJ/m
Copper weight: 25,00 kg/km 41,00 kg/km

Norms
Applicable standards: EIB standard EIB standard
Halogen-free acc. to 60754-2 Flame-retardant acc. to EN 50265-2-1
Flame-retardant acc. to EN 50265-2-1

Application
HELUKABEL E-BUS FRNC + PVC for fixed installation. If the application requires a halogen-free installation, the FRNC version is the right choice. The
E-Bus cable is intended for transmission of bus signals in intelligent building systems. The cables ensure perfect communication in compliance with
EIB regulations. They can be installed over, in and under plaster, in conduits and cable channels, in dry, damp and wet rooms as well as outdoors - if
protected from direct sunlight. Wiring together with high-power cables is possible without limitation. The EIB bus can be used to control lighting,
blinds, heating, ventilation, indicator boards etc. R
Part no. 80826, E-BUS 81077, E-BUS
Dimensions and specifications may be changed without prior notice.

761
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
E-BUS DIRECT BURIAL
PE, ERD

Type Direct burial


Cable structure 2x2x0.8 mm
Inner conductor: Copper, bare
Core insulation: PE
Core colours: wh, ye, rd, bk
Stranding element: Star quad
Shielding 1: Polyester foil over stranded bundle
Shielding 2: -
Total shielding: Polyester foil, aluminium-lined
Outer sheath material: PE
Cable external diameter: app. 8,8 mm 0,3 mm
Outer sheath colour: Black similar to RAL 9005

Electrical data
Characteristic impedance: 100 Ohm
Conductor resistance, max.: 73,2 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 146 Ohm/km max.
Mutual capacitance: 55 nF/km nom.
Test voltage: 0,8 kV

Technical data
Weight: app. 75 kg/km
bending radius, repeated: 130 mm
Operating temperature range min.: -20C
Operating temperature range max.: +70C
Caloric load, approx. value: 2,00 MJ/m
Copper weight: 25,00 kg/km

Norms
Applicable standards: EIB standard
Halogen-free acc. to 60754-2

Application
HELUKABEL E-BUS ERD with PE jacket for fixed installation in the ground or outdoors and as a connection between buildings or to EIB components
on the building. They can be installed over, in and under plaster, in conduits and cable channels, in dry, damp and wet rooms as well as outdoors - if
protected from direct sunlight. Wiring together with high-power cables is possible without limitation. The EIB bus can be used to control lighting,
blinds, heating, ventilation, indicator boards etc.

Part no. 802800, E-BUS BURIAL


Dimensions and specifications may be changed without prior notice.

762
Data, Network and Bus Technology / HELUKABEL BUS-Cables

BUS Cables
KH-BUS
PVC + FRNC

Type Hospital-Bus Hospital-Bus


Cable structure 2x1.5mm (stranded) + 2x1.5mm (stranded) +
2x2x0.60 mm (solid) 2x2x0.60 mm (solid)
Inner conductor, power core: Copper, bare Copper, bare
Inner conductor, data core: Copper, tinned Copper, tinned
Core insulation, power core: PVC PE
Core insulation, data core: PE PE
Core colours, power core: rd, bu rd, bu
Core colours, data core: gn/ye, gy/pk gn/ye, gy/pk
Stranding element, data core: Double core Double core
Shielding, data pair: PP foil + aluminium-lined foil + PP foil PP foil + aluminium-lined foil + PP foil
Drain wire: yes yes
Outer sheath material: PVC FRNC
Cable external diameter: app. 8,0 mm 0,3 mm app. 8,0 mm 0,3 mm
Outer sheath colour: Green similar to RAL 6001 Green similar to RAL 6001

Electrical data
Insulation resistance, min.: 0,02 GOhm x km 0,02 GOhm x km
Mutual capacitance: 70 nF/km nom. 70 nF/km nom.
Test voltage: 2 kV 2 kV

Technical data
Weight: app. 90 kg/km app. 93 kg/km
bending radius, repeated: 120 mm 120 mm
Operating temperature range min.: -40C -25C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 1,01 MJ/m 0,86 MJ/m
Copper weight: 53,00 kg/km 53,00 kg/km

Application
HELUKABEL KH-BUS PVC + FRNC for fixed installation of patient calling systems. Simple and fast installation is an important factor there. For this
reason, a 6-conductor hybrid cable is used to connect the individual components of the calling system. This cable is used for the power supply, speech
and data transmission. The FRNC version is the right choice when a halogen-free installation is required.

Part no. 81085, KH-BUS 81447, KH-BUS


Dimensions and specifications may be changed without prior notice.

763
MEDIA TECHNOLOGY

Designation Properties Page

Audio Audio cables with braided shielding 766

Audio Audio cables, multicore with braided shielding 767

Audio Audio cables with foil shielding, single pair 768

Audio Audio cables, multipaired with foil shielding 769

Audio Audio cables, multipaired, spirally screened pairs and overall braided shielding 770

Audio Digital audio cables AES/EBU, single pair with spiral screen 771

Audio Digital audio cables AES/EBU, single pair with foil/braided shielding 772

Audio Digital audio cables AES/EBU, multipaired, pair and overall foil shielding 773

Audio Digital audio cables AES/EBU, multipaired, spirally screened pairs and overall foil shielding 774

Audio & Light AES/EBU & DMX patch cable 775

Audio & Light AES/EBU & DMX cables 776

Audio & Light AES/EBU TP DMX 512 777

Audio & Light DMX cables, multicore with spiral screen 778

Light+Power DMX-POWER 779

HELUSOUND DMX + Power 780

Audio Instrument cables with spiral screen 781

Audio Microphone cables with spiral screen, paired 782

Audio Microphone cables with braided shielding 783

Audio Microphone cables with braided shielding, star quads 784

Speaker cables 785

HELUSOUND 400 PVC


Speaker cables, round 786

HELUSOUND 500 PUR 787

HELUSOUND 600 FRNC, halogen-free 788

Audio Speaker cables, coaxial 789

Load cables 300/500 V + 600/1000 V 790

Video cables 791

Video Video cables, multicore 792

Video Camera cables 793

765
Media Technology

Audio
Audio cables with braided shielding

Type HELUSOUND audio cable analog


Cable structure 2x0,25 + 0,25
Conductor material: Copper, bare
Core insulation: PVC
Core colours: rd, wh
Stranding element: 2 cores with 1 filler and 1 earth conductor stranded
Sheath material: PVC
Cable external diameter: approx. 3,4 mm
Sheath colour: black

Electrical data
Conductor resistance, max.: 75 Ohm/km
Insulation resistance, min.: 5 MOhm x km

Technical data
Weight: approx. 20 kg/km
Min. bending radius for laying: 35 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 13,5 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. Cable structure Conductor Outer diameter Cop. Weight


resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400000 2x0,25 + 0,25 < 75,0 3,4 13,5 20,0
400001 2x0,33+0,33 < 60,0 4,0 16,3 26,0
400002 2x0,5+0,33 < 36,8 5,6 26,1 49,0

Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND audio cable is a 2-core, shielded multipurpose cable with earth conductor. It is particularly suitable for use in microphone, radio,
studio and transmission systems.
Analog cable for short transmission distances and low frequencies.

766
Media Technology

Audio
Audio cables, multicore, with braided shielding

Type HELUSOUND audio cable analog


Cable structure 2x0,26
Conductor material: Copper, bare
Core insulation: PE
Stranding element: pairs stranded
Sheath material: PVC
Cable external diameter: approx. 5,2 mm
Sheath colour: black

Electrical data
Conductor resistance, max.: 73,9 Ohm/km
Insulation resistance, min.: 1 GOhm x km

Technical data
Weight: approx. 37 kg/km
Min. bending radius for laying: 52 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 16,8 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. Cable structure Conductor Outer diameter Cop. Weight


resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400003 2x0,26 < 73,9 5,2 16,8 37,0
400004 2x0,33 < 61,6 5,3 18,2 38,0
400005 4x0,33 < 61,6 5,9 27,2 52,0
400006 2x0,50 < 39,0 5,7 22,0 46,0
400007 2x0,75 < 26,0 7,2 30,0 70,0
400008 3x0,75 < 26,0 7,7 50,0 90,0
400009 4x0,75 < 26,0 8,3 60,0 102,0
400010 5x0,75 < 26,0 8,9 72,0 120,0

Dimensions and specifications may be changed without prior notice.

Application
The 2-5-core shielded HELUSOUND audio cable with a common PE core insulation, braided shielding and PVC outer sheath is especially well suited
for use in microphone, loudspeaker, radio and transmission systems.

767
Media Technology

Audio
Audio cables with foil shielding, single pair

Type Analog audio cables


Cable structure 2x0,22
Conductor material: Copper, tinned
Core insulation: PE
Core colours: rd, bu
Stranding element: 2 cores with 1 filler
Sheath material: PVC
Cable external diameter: approx. 3,4 mm
Sheath colour: black

Electrical data
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km

Technical data
Weight: approx. 17 kg/km
Min. bending radius for laying: 35 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 6,6 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. 400011


Dimensions and specifications may be changed without prior notice.

Application
The 2-core HELUSOUND audio cable is a foil shielded cable with earth conductor. This symmetrical cable is suitable for use in racks and for studio
cabling.

768
Media Technology

Audio
Audio cables, multipaired, pairs with foil shielding

Type Analog audio cables


Cable structure 2x2x0,22
Conductor material: Copper, tinned
Core insulation: PE
Core colours: rd, bu
Stranding element: pairs stranded
Sheath material: PVC
Cable external diameter: approx. 7,6 mm
Sheath colour: black

Electrical data
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km

Technical data
Weight: approx. 72 kg/km
Min. bending radius for laying: 76 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 15,0 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. Cable structure Outer diameter Cop. Weight


approx. mm weight approx. kg / km
kg / km
400012 2x2x0,22 7,6 15,0 72,0
400013 4x2x0,22 9,2 29,0 100,0
400014 8x2x0,22 12,2 59,0 179,0
400015 12x2x0,22 14,2 90,0 248,0
400016 16x2x0,22 16,4 111,0 337,0
400017 20x2x0,22 18,4 149,0 421,0
400018 24x2x0,22 20,4 178,0 493,0
400019 32x2x0,22 22,4 238,0 620,0
400020 40x2x0,22 24,6 303,0 759,0

Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND audio cable is an insulated, multi-core audio cable which is screened symmetrically and in pairs. The cable is particularly suitable
for permanent laying in public buildings, such as, e.g. theatres or music stages and for permanent studio installation.

769
Media Technology

Audio
Audio cables, multipaired, spirally screened pairs and overall braided shielding

Type Analog audio cables Analog audio cables


Cable structure 12x2x0,14 16x2x0,14
Conductor material: Copper, tinned Copper, tinned
Core insulation: TPE TPE
Stranding element: pairs stranded pairs stranded
Sheath material: PUR PUR
Cable external diameter: approx. 12,7 mm approx. 14,1 mm
Sheath colour: black black

Electrical data
Conductor resistance, max.: 150 Ohm/km 150 Ohm/km
Insulation resistance, min.: 100 MOhm x km 100 MOhm x km

Technical data
Weight: approx. 190 kg/km approx. 247 kg/km
Min. bending radius for laying: 127 mm 142 mm
Operating temperature range min.: -25C -25C
Operating temperature range max.: +70C +70C
Copper weight: 118,0 kg/km 165,0 kg/km

Norms Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2

Part no. 400042 400043


Dimensions and specifications may be changed without prior notice.

Application
The multipaired HELUSOUND special sound audio cable has individually shielded pairs and is protected by an additional braided shielding and ribbed
PUR sheath. This cable is particularly suitable for use in mobile radio and transmission systems.

770
Media Technology

Audio
AES/EBU digital audio cables, single pair, with spiral screen

Type Digital audio cables


Cable structure 2x0,22
Conductor material: Copper, bare
Core insulation: PE
Core colours: rd, bu
Stranding element: 2 cores with 1 earth conductor
Sheath material: PVC
Cable external diameter: approx. 5,0 mm
Sheath colour: black

Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km

Technical data
Weight: approx. 35 kg/km
Min. bending radius for laying: 50 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 14,7 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. 400021


Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND AES/EBU audio cable is a 2-core, symmetrical and shielded digital sound cable with flexible spiral screen and PVC outer sheath.
The cable is suitable for longer transmission rates and larger data volumes, the transmission of digital and analog audio signals and can therefore, for
example, be used for connecting audio amplifiers, digital mixers, DAT recorders etc. The cable is also available with PUR outer sheath.

771
Media Technology

Audio
AES/EBU digital audio cables, single pair, foil/braided shielding

Type Digital audio cables


Cable structure 2x0,22
Conductor material: Copper, tinned
Core insulation: Cell PE
Core colours: rd, bu
Stranding element: 2 cores with 1 earth conductor
Sheath material: PVC
Cable external diameter: approx. 6,0 mm
Sheath colour: black

Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km

Technical data
Weight: approx. 43 kg/km
Min. bending radius for laying: 60 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 16,5 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. Cable structure Screen Conductor Outer diameter Cop. Weight
resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400022 2x0,22 Foil + braid < 86,0 6,0 16,5 43,0
400023 2x0,22 Foil + braid < 86,0 4,5 15,7 25,0
400024 2x0,22 Foil < 86,0 4,2 7,3 18,0

Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND AES/EBU audio cable is a 2-core, symmetrical and shielded digital sound cable. The cable is available in three different versions.
The standard version is characterised by double shielding; the patch variant has reduced outside diameter and the foil shielded variant is suitable for
the permanent wiring of digital devices. All three versions are suitable for the transmission of digital audio signals.

772
Media Technology

Audio
AES/EBU digital audio cables, multipaired, pairs with foil shielding and overall
foil shielding

Type Digital audio cables


Cable structure 2x2x0,22
Conductor material: Copper, tinned
Core insulation: Cell PE
Core colours: rd, bu
Stranding element: 2 cores with 1 earth conductor
Sheath material: PVC
Cable external diameter: approx. 9,9 mm
Sheath colour: black

Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km

Technical data
Weight: approx. 85 kg/km
Min. bending radius for laying: 100 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 16,0 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. Cable structure Outer diameter Cop. Weight


approx. mm weight approx. kg / km
kg / km
400025 2x2x0,22 9,9 16,0 85,0
400026 4x2x0,22 11,8 31,0 119,0
400027 6x2x0,22 14,9 46,0 195,0
400028 8x2x0,22 16,1 59,0 232,0
400029 12x2x0,22 19,1 85,0 330,0
400158 24x2x0,22 24,5 162,0 670,0

Dimensions and specifications may be changed without prior notice.

Application
The multipaired, digital HELUSOUND AES/EBU audio cable is characterised by its shielding in pairs, its element sheaths and by the additional overall
sheath. This cable is suitable for the transmission of digital audio signals.

773
Media Technology

Audio
AES/EBU digital audio cables, multipaired, spirally screened pairs and overall
foil shielding

Type Digital audio cables


Cable structure 12x2x0,22
Conductor material: Copper, bare
Core insulation: Cell PE
Core colours: rd, bu
Stranding element: 2 cores with 1 earth conductor
Sheath material: PVC
Cable external diameter: approx. 17,0 mm
Sheath colour: black

Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km

Technical data
Weight: approx. 320 kg/km
Min. bending radius for laying: 170 mm
Operating temperature range min.: -20C
Operating temperature range max.: +70C
Copper weight: 171,0 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. 400030


Dimensions and specifications may be changed without prior notice.

Application
The multipaired, digital HELUSOUND AES/EBU audio cable is characterised by its shielding in pairs, its element sheaths and by the additional overall
sheath. This cable is suitable for the transmission of digital audio signals.

774
Media Technology

Audio & Light


AES/EBU & DMX patch cable

Type DMX cables


Cable structure 2x0,22
Conductor material: Copper, tinned
Core insulation: Cell PE
Core colours: rd, bu
Stranding element: 2 cores with 1 filler
Sheath material: PVC
Cable external diameter: approx. 5,0 mm
Sheath colour: blue

Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 80 Ohm/km
Insulation resistance, min.: 5 GOhm x km

Technical data
Weight: approx. 33 kg/km
Min. bending radius for laying: 50 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Copper weight: 14,0 kg/km

Part no. 400031


Dimensions and specifications may be changed without prior notice.

Application
The 2-core HELUSOUND AES/EBU & DMX patch cable is foil shielded and optimally protected against external interference by its copper spiral screen.
This cable is suitable for indoor use for permanent laying for the control of lighting systems or for patching in studio technology.

775
Media Technology

Audio & Light


AES/EBU & DMX cables

Type DMX cables DMX cables


Cable structure 2x0,34 4x0,34
Conductor material: Copper, bare Copper, bare
Core insulation: Cell PE Cell PE
Core colours: rd, wh wh,gn,bn,ye
Stranding element: 2 cores with textile filler stranded Star quad
Sheath material: PVC PVC
Cable external diameter: approx. 6,4 mm approx. 7,0 mm
Sheath colour: black black

Electrical data
Characteristic impedance: 110 Ohm 110 Ohm
Conductor resistance, max.: 53 Ohm/km 53 Ohm/km
Insulation resistance, min.: 10 GOhm x km 5 GOhm x km

Technical data
Weight: approx. 50 kg/km approx. 65 kg/km
Min. bending radius for laying: 64 mm 70 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Copper weight: 18,0 kg/km 29,0 kg/km

Part no. 400032 400033


Dimensions and specifications may be changed without prior notice.

Application
The 2-core HELUSOUND AES/EBU & DMX patch cable is protected against external interferences by its copper spiral screen. This cable is suitable
for permanent laying for the control of lighting systems or for connecting digital audio amplifiers. It can be installed indoors and outdoors. The max.
transmission path for DMX control amounts approx. 1000m

776
Media Technology

Audio & Light


AES/EBU TP DMX 512

Type DMX cables


Cable structure 2x2x0,22
Conductor material: Copper, tinned
Core insulation: Cell PE
Core colours: or/wh, bu/wh
Stranding element: pairs stranded
Sheath material: PVC soft
Cable external diameter: approx. 8,0 mm
Sheath colour: black matt

Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 85 Ohm/km
Insulation resistance, min.: 100 GOhm x km

Technical data
Weight: approx. 76 kg/km
Min. bending radius for laying: 80 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 38,0 kg/km

Part no. 400034


Dimensions and specifications may be changed without prior notice.

Application
The 4-core HELUSOUND AES/EBU & DMX cable is protected against external interference by its AL/PT foil, its copper spiral screen and its PVC outer
sheath. This cable is suitable for controlling all types of digital equipment. Also to use as microphon cabel.

777
Media Technology

Audio & Light


DMX cables, multicore with spiral screen

Type DMX cables


Cable structure 2x0,22+0,22
Conductor material: Copper, tinned
Core insulation: PE spumed
Core colours: wh,bu+rd
Stranding element: pair and core stranded together
Sheath material: PVC
Cable external diameter: approx. 6,4 mm
Sheath colour: black

Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 MOhm x km

Technical data
Weight: approx. 79 kg/km
Min. bending radius for laying: 64 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 66,0 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. 400035


Dimensions and specifications may be changed without prior notice.

Application
The 3-core, shielded HELUSOUND digital sound cable consists of a symmetrical pair and an additional third core. A double spiral screen and the PVC
outer sheath protect the cable against electrical interference. This AES/EBU and DMX compliant (110 Ohm) special cable is suitable for the transmission
of digital audio signals and can therefore, for example, be used for connecting digital mixers, audio amplifiers, DAT recorders, light and scanner
systems etc.

778
Media Technology

Light+Power
DMX-POWER

Type DMX cables


Cable structure (1x2x0,24)+2x1,0
Conductor material: Copper, bare
Core insulation: Foam-Skin-PE (DMX), PVC (Power)
Core colours: red, white (DMX); yellow, green (Power)
Stranding element: 2 cores with 1 filler
Sheath material: PVC soft
Cable external diameter: approx. 7,4 mm
Sheath colour: black matt

Electrical data
Characteristic impedance: 110 Ohm

Technical data
Weight: approx. 74 kg/km
Copper weight: 36,0 kg/km

Part no. 400081


Dimensions and specifications may be changed without prior notice.

Application
The hybrid DMX Power cable is used in the professional DMX light controller. It transmits power for the light and control signals for the movement.
The cable is compact, flexible and easy to process.

779
Media Technology

HELUSOUND DMX+POWER

Type DMX cables


Cable structure (1x2x0,25)+3G1,5
Conductor material: Copper, bare
Core insulation: Foam-Skin-PE (DMX), PVC (Power)
Core insulation 2: PVC
Core colours: red, white (DMX); brown, blue, green/yellow (Power)
Stranding element: DMX-Element together with Power-Element and filler stranded
Sheath material: PVC flexible at low temperatures
Cable external diameter: approx. 13,2 mm
Sheath colour: black

Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 78 Ohm/km
Insulation resistance, min.: 20 GOhm x km

Technical data
Weight: approx. 50 kg/km
Min. bending radius for laying: 64 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Copper weight: 60,5 kg/km

Part no. 400151


Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND DMX+POWER hybrid cable combines a shielded light control wire and the power supply wire. The DMX-cable, which is shielded
by a tin-coated copper braiding is perfectly suited for the control of light systems and mixing boards (110 Ohm characteristic intrinsic impedance). It
highlights a soft PVC insulation and it is qualified for the use at indoor and outdoor installations. The DMX cable can also be used for the transmission
of audio signals such as a microphone wire or as a power supply wire for active loudspeaker systems.

780
Media Technology

Audio
Instrument cables with spiral screen

Type Instrument cables Instrument cables


Cable structure 1x0,22 1x0,38
Conductor material: Copper, bare Copper, bare
Core insulation: Foam-skin-PE Cell PE
Sheath material: PVC PVC
Cable external diameter: approx. 5,9 mm approx. 7,0 mm
Sheath colour: black black

Electrical data
Conductor resistance, max.: 86 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km

Technical data
Weight: approx. 44 kg/km approx. 55 kg/km
Min. bending radius for laying: 60 mm 70 mm
Operating temperature range min.: -25C -25C
Operating temperature range max.: +70C +70C
Copper weight: 7,9 kg/km 29,0 kg/km

Norms Corrosiveness acc. to EN50267-2-3 Corrosiveness acc. to EN50267-2-3

Part no. 400036 400037


Dimensions and specifications may be changed without prior notice.

Application
The HELUSOUND instrument cable with spiral screen is a non-symmetrical, double shielded cable. This cable is specially suitable for connecting high
ohmic components such as synthesisers, keyboards or guitars in professional stage and studio operation. The high-quality 1x0.38 special cable has
an increased cross-section, a semi-conductor layer and a double spiral screen, which makes it suitable for the most stringent requirements of professional
stages and studios.

781
Media Technology

Audio
Microphone cables with spiral screen, paired

Type Microphone cable Microphone cable


Cable structure 2x0,22 2x0,15
Conductor material: Copper, bare Copper, bare
Core insulation: PE PVC
Core colours: rd, bu rd, wh
Stranding element: 2 cores with textile filler stranded pairs stranded
Sheath material: PVC PVC
Cable external diameter: approx. 6,0 mm approx. 4,2 mm
Sheath colour: black black

Electrical data
Conductor resistance, max.: 86 Ohm/km 120 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km

Technical data
Weight: approx. 55 kg/km approx. 27 kg/km
Min. bending radius for laying: 60 mm 42 mm
Operating temperature range min.: -25C -25C
Operating temperature range max.: +70C +70C
Copper weight: 12,1 kg/km 14,0 kg/km

Norms Corrosiveness acc. to EN50267-2-3 Corrosiveness acc. to EN50267-2-3

Part no. 400038 400039


Dimensions and specifications may be changed without prior notice.

Application
The 2-core HELUSOUND microphone cable with spiral screen is suitable for use in professional stage and studio operation. The microphone cable
2x0.15 has a double spiral screen made of bare copper wires.

782
Media Technology

Audio
Microphone cables with braided shielding

Type Microphone cable Microphone cable


Cable structure 2x0,34 2x0,50
Conductor material: Copper, bare Copper, bare
Core insulation: PE PE
Core colours: rd, bu rd, wh
Stranding element: 2 cores with textile filler stranded 2 cores with textile filler stranded
Sheath material: PVC PVC
Cable external diameter: approx. 6,5 mm approx. 6,7 mm
Sheath colour: black black

Electrical data
Conductor resistance, max.: 53 Ohm/km 37 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km

Technical data
Weight: approx. 30 kg/km approx. 59 kg/km
Min. bending radius for laying: 65 mm 67 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Copper weight: 15,2 kg/km 37,0 kg/km

Part no. 400040 400080


Dimensions and specifications may be changed without prior notice.

Application
The 2-wire HELUSOUND microphone cable with copper braid shield is suitable for use in the professional stage and studio operations, as well as for
fixed installation. The line is characterized by its highly flexible PVC jacket.

783
Media Technology

Audio
Microphone cables with braided shielding, star quads

Type Microphone cable


Cable structure 4x0,22
Conductor material: Copper, bare
Core insulation: PE
Core colours: rd,bu,gn,bk
Stranding element: Star quad
Drain wire: AWG 26/7, copper bare
Inner sheath material: PE
Sheath material: PVC
Cable external diameter: approx. 6,1 mm
Sheath colour: black

Electrical data
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km

Technical data
Weight: approx. 50 kg/km
Min. bending radius for laying: 62 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 25,0 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. 400041


Dimensions and specifications may be changed without prior notice.

Application
The 4-core HELUSOUND microphone cable is stranded in star quads and suitable for special application due to its earth conductor and braided
shielding. It is e.g. used as a stereo cable in the area of professional studio and microphone technique.
Easy stripping.

784
Media Technology

Loudspeaker Cables

Cross section (mm) 2 x 0,5 2 x 0,5 2 x 0,75 2 x 0,75 2 x 1,5 2 x 1,5 2 x 2,5 2 x 2,5 2x4 2x4
Part no. 40180 40023 40181 40024 40182 40025 40183 40026 40184 40027

Cable structure
Conductor material: Copper litz wire, bare
Identification: Grooves
Cond. make-up 16 x 0,20 16 x 0,20 24 x 0,20 24 x 0,20 28 x 0,25 28 x 0,25 48 x 0,25 48 x 0,25 55 x 0,30 55 x 0,30
Insulation h x w mm 2,0 x 5,0 2,1 x 4,7 2,2 x 4,9 2,2 x 4,9 2,6 x 5,5 2,6 x 5,5 3,3 x 7,0 3,3 x 7,0 4,3 x 8,2 4,3 x 8,2
Sheath material PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
Sheath colour transparent black/red transparent black/red transparent black/red transparent black/red transparent black/red
Weight approx. kg / km 15 15 20 20 37 37 63 63 80 80

Electrical characteristics
Loop resistance
max. (Ohm/km) 70 70 47 47 23 23 14 14 9 9
CapacitancepF/m 47 47 60 60 67 67 67 67 64 64
Inductance H/m at
1 kHz 0,7 0,67 0,61 0,61 0,54 0,54 0,54 0,54 0,58 0,58
10 kHz 0,8 0,79 0,73 0,73 0,59 0,59 0,62 0,62 0,65 0,65
100 kHz 0,8 0,85 0,73 0,73 0,59 0,59 0,62 0,62 0,65 0,65
1000 kHz 0,8 0,8 0,67 0,67 0,52 0,52 0,56 0,56 0,59 0,59

Copper weight kg/km 9,6 9,6 14,4 14,4 28,8 28,8 48,0 48,0 76,8 76,8

Cross section (mm) 2 x 1,5 2 x 2,5 2x4 2x6 2 x 10


Part no. 40185 40186 40187 40188 40189

Cable structure
Conductor material: Bare copper litz wire, highly flexible
Identification: Stripes
Cond. make-up 189 x 0,10 322 x 0,10 511 x 0,10 777 x 0,10 1273 x 0,10
Insulation h x w mm 3,1 x 6,5 3,6 x 7,5 5 x 10,2 6,1 x 12,5 7,0 x 15,0
Sheath material PVC PVC PVC PVC PVC
Sheath colour transparent transparent transparent transparent transparent
Weight approx. kg / km 41 60 79 136 254

Electrical characteristics
Loop resistance
max. (Ohm/km) 23 14 9 6 3
CapacitancepF/m 67 53 50 54 59
Inductance H/m at
1 kHz 0,54 0,48 0,49 0,46 0,45
10 kHz 0,61 0,55 0,56 0,54 0,53
100 kHz 0,62 0,59 0,6 0,56 0,56
1000 kHz 0,55 0,54 0,56 0,53 0,52

Copper weight kg/km 28,8 48,0 76,8 115,2 192,0

Dimensions and specifications may be changed without prior notice. (RM01)

Note
The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers.

785
Media Technology

HELUSOUND 400 PVC


Speaker cables, round

Type Speaker cable HELUSOUND 400


Cable structure 2x1,5
Conductor material: Copper, bare
Core insulation: PVC
Core colours: rd, bk
Sheath material: PVC
Cable external diameter: approx. 6,6 mm
Sheath colour: black

Electrical data
Conductor resistance, max.: 12,7 Ohm/km

Technical data
Weight: approx. 73,4 kg/km
Min. bending radius for laying: 33 mm
Operating temperature range min.: -10C
Operating temperature range max.: +70C
Copper weight: 28,8 kg/km

Part no. Cable structure Conductor Outer diameter Cop. Weight


resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400089 2x1,5 < 12,7 6,6 28,8 73,4
400090 2x2,5 < 7,9 7,5 48,0 106,9
400091 2x4,0 < 4,9 9,4 76,8 163,7
400092 4x2,5 < 7,9 8,8 96,0 169,3
400093 4x4,0 < 4,9 11,6 153,6 272,4
400060 8x2,5 < 7,9 13,5 192,0 349,0
400094 8x4,0 < 4,9 16,8 307,2 541,6

Dimensions and specifications may be changed without prior notice.

Application
All products of the HELUSOUND 400 LOUDSPEAKER series impress with their extremely high flexibility. 0,15 stranded wires and a very soft PVC
outer sheath make this possible. These cables are particularly used in mobile applications on stages, in studios or in the conference industry.

786
Media Technology

HELUSOUND 500 PUR

Type Speaker cable HELUSOUND 500 PUR


Cable structure 2x1,5
Conductor material: Copper, bare
Core insulation: PVC
Core colours: rd, bk
Stranding element: pairs stranded
Sheath material: PUR
Cable external diameter: approx. 6,6 mm
Sheath colour: black

Electrical data
Conductor resistance, max.: 12,7 Ohm/km

Technical data
Weight: approx. 66,9 kg/km
Min. bending radius for laying: 33 mm
Operating temperature range min.: -25C
Operating temperature range max.: +80C
Copper weight: 28,8 kg/km

Part no. Cable structure Conductor Outer diameter Cop. Weight


resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400109 2x1,5 < 12,7 6,6 28,8 66,9
400110 2x2,5 < 7,9 7,5 48,0 98,5
400111 2x4,0 < 4,9 9,4 76,8 150,2
400112 4x2,5 < 7,9 8,8 96,0 159,1
400113 4x4,0 < 4,9 11,6 153,6 253,0
400114 8x2,5 < 7,9 13,5 192,0 332,1
400115 8x4,0 < 4,9 16,8 307,2 499,5

Dimensions and specifications may be changed without prior notice.

Application
The robust solution for medium and high mechanical stresses, as robust, abrasion-resistant and cut resistant. Also suitable for outdoor use.

787
Media Technology

HELUSOUND 600 FRNC, halogen-free

Type Speaker cable HELUSOUND 600 FRNC


Cable structure 2x1,5
Conductor material: Copper, bare
Core insulation: FRNC
Core colours: rd, bk
Stranding element: pairs stranded
Sheath material: FRNC
Cable external diameter: approx. 6,6 mm
Sheath colour: black

Electrical data
Conductor resistance, max.: 12,7 Ohm/km

Technical data
Weight: approx. 77 kg/km
Min. bending radius for laying: 33 mm
Operating temperature range min.: -5C
Operating temperature range max.: +70C
Copper weight: 28,8 kg/km

Part no. Cable structure Conductor Outer diameter Cop. Weight


resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400116 2x1,5 < 12,7 6,6 28,8 77,0
400117 2x2,5 < 7,9 7,5 48,0 105,6
400118 2x4,0 < 4,9 9,4 76,8 166,9
400119 4x2,5 < 7,9 8,8 96,0 161,5
400120 4x4,0 < 4,9 11,6 153,6 271,6
400121 8x2,5 < 7,9 13,5 192,0 338,6
400122 8x4,0 < 4,9 16,8 307,2 531,5

Dimensions and specifications may be changed without prior notice.

Application
The safe solution for increasing demands on the security in case of fire, as flame retardant, low smoke, halogen-free, no corrosion damage by released
gases and fumes, no flame propagation provide for local flame propagation for the integrity of important systems.

788
Media Technology

Audio
Speaker cables, coaxial

Type Speaker cable Speaker cable


Cable structure 2x2,5 2x4,0
Conductor material: Copper, bare Copper, bare
Core insulation: PVC PVC
Core colours: Black Black
Sheath material: PVC PVC
Cable external diameter: approx. 6,8 mm approx. 7,9 mm
Sheath colour: black black

Electrical data
Conductor resistance, max.: 7,98 Ohm/km 4,95 Ohm/km
Insulation resistance, min.: 5 MOhm x km 5 MOhm x km

Technical data
Weight: approx. 84 kg/km approx. 129 kg/km
Min. bending radius for laying: 68 mm 80 mm
Operating temperature range min.: -25C -25C
Operating temperature range max.: +70C +70C
Copper weight: 52,0 kg/km 87,0 kg/km

Norms Corrosiveness acc. to EN50267-2-3 Corrosiveness acc. to EN50267-2-3

Part no. 400061 400062


Dimensions and specifications may be changed without prior notice.

Application
The coaxial HELUSOUND speaker cable is protected by a counter-rotating double spiral shield and outer jacket. It is characterized due to the
construction, in addition to robustness and good drum reeling, especially by high flexibilty and small dimensions.

789
Media Technology

Loadcable 300/500 V + 600/1000 V

Type Loadcable 300V/500V/0,6kV/1kV


Cable structure
Conductor material: Copper, bare
Core insulation: PVC flexible at low temperatures
Core colours: black number coded + gn/ye
Stranding element: 14 cores stranded
Sheath material: PVC flexible at low temperatures
Cable external diameter: approx. 13,4 mm
Sheath colour: black

Electrical data
Conductor resistance, max.: 13,3 Ohm/km

Technical data
Weight: approx. 322 kg/km
Min. bending radius for laying: 53,6 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Copper weight: 201,6 kg/km
Loadcable 300/500 V
Part no. Cable structure Conductor Outer diameter Cop. Weight
resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400143 14 G 1,5 < 13,3 13,4 201,6 322,0
400144 18 G 1,5 < 13,3 15,2 259,2 422,0
400145 14 G 2,5 < 7,98 16,6 336,0 487,0
400146 18 G 2,5 < 7,98 19,0 432,0 634,0

Loadcable 0,6/1 kV
Part no. Cable structure Conductor Outer diameter Cop. Weight
resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400147 14 G 1,5 < 13,3 17,7 201,6 430,0
400148 18 G 1,5 < 13,3 20,2 259,2 560,0
400149 14 G 2,5 < 7,98 20,0 336,0 604,0
400150 18 G 2,5 < 7,98 22,6 432,0 778,0

Dimensions and specifications may be changed without prior notice.

Application
The highly flexible load cables are applied at medium mechanical stress in the professional stage and lighting technology, and other load circuits. The
flexibility is achieved through the building with extra fine 0,15 mm strands and the core and sheath insulation from cold-flexible PVC.

790
Media Technology

Video Cables

used as Indoors Indoors, Indoors Indoors Indoors, Indoors Indoors Indoors Indoors,
underground underground outdoors
Type 0,6/2,8 1,0/6,6 1.0/6.6 2YD 1,0/6,6 1.0/6.6D 0.6L/3.7 0,6/3,7 1.0/6.6D 0,6L/3,7+2x0,75
Part no. 40022 40056 40175 40173 40073 40170 40171 40174 40028

Cable structure
Inner conductor diameter mm 0,6 1 1 1 1 0,2 0,6 1 0,6
Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare
Insulation mm 2,8 Cell PE 6,4 PE 6,4 PE 6,4 PE 6,4 PE 3,7 PE 3,7 PE 6,4 PE 3,7 PE
1st Outer conductor Polyester foil Bare copper Bare copper Bare copper Bare copper Bare copper Bare copper Bare copper Bare copper braid
coated with braid braid braid braid braid braid braid
aluminium on
both sides
approx. mm - 7 7 7 7 4,2 4,3 7 -
Inner steath/Foil - - PE - Foil - - Foil -
approx. mm - - 8,5 - - - - - -
2nd Outer conductor Tinned copper no Bare copper no Bare copper no no Bare copper -
braid braid braid braid
approx. mm - - 9,1 - 7,6 - - 7,6 -
Outer sheath FRNC PE PVC PVC PE PVC PVC PVC PVC
Sheath colour green black green green black green green green black
Outer approx. mm 4,3 8,8 11,0 8,8 9,0 6,1 6,1 9,0 11,8
Min. bending radius approx. mm 25 45 55 45 50 30 30 50 50
Weight approx. kg / km 24 93 151 95 125 48 48 128 85

Electrical characteristics
Impedance (Ohm) 75 2 75 1 75 1 75 1 75 1 75 1 75 1 75 1 75 3
Attenuation at 20C
(db/100m)
1 MHz 0,9 0,6 0,6 0,6 0,6 1,2 1,1 0,6 1,1
5 MHz 2,2 1,3 1,4 1,3 1,4 2,6 2,5 1,4 2,5
7 MHz 2,6 - - - - - - - -
10 MHz 3,2 2 2 2 2 3,6 3,5 2 3,5
50 MHz 7,5 - - - - - - - -
100 MHz 10,2 - - - - - - - -
Propagation velocity v/c 0,8 0,66 0,66 0,66 0,66 0,66 0,66 0,66 0

DC resistance at 20C
Inner conductor max.Ohm/km 63 22 24 22 24 83 63 24 63
Outer conductor max.Ohm/km 21 7,5 6,5 7,5 3,5 12,5 13 3,5 13
CapacitancepF/m 54 67 67 67 67 67 67 67 67
Test voltage (50 Hz, kVeff.) 3,5 7 7 7 7 4,2 4,2 7 4

Working voltage at (kV)


Pulse operation - 6 6 6 6 3,6 3,6 6 -
HF-operation (peak value) - 3 3 3 3 1,8 1,8 3 -
DC operation - 14 14 14 14 8 8 14 -
Screening efficiency (dB)
50 and 900 MHz 90 - - - - - - - -
Copper weight kg/km 11,0 32,0 78,0 32,0 78,0 22,0 22,0 78,0 38,0

Dimensions and specifications may be changed without prior notice. (RM01)

Note S
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
ALPR=Polyesterfoil coated with Aluminium on both sides
bl=Bare, bk=Black, Cu=Copper, D=2xbraiding, FRNC=Flame Retardant Non-Corrosive, G=Braid, gn=Green, PE=Polyethylene, PEE=Cell-PE,
PVC=Polyvinylchloride

791
Media Technology

Video
Video cables, multicore

Type Video Cables


Cable structure 3x(0,6/2,8)
Conductor material: Copper, bare
Core insulation: Cell PE
Sheath material: PVC
Cable external diameter: approx. 12,9 mm
Sheath colour: black

Electrical data
Characteristic impedance: 75 Ohm
Inner conductor resistance, max.: 65 Ohm/km

Technical data
Weight: approx. 178 kg/km
Min. bending radius for laying: 130 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 49,0 kg/km

Norms Corrosiveness acc. to EN50267-2-3

Part no. Cable structure Outer diameter Cop. Weight


approx. mm weight approx. kg / km
kg / km
400068 3x(0,6/2,8) 12,9 49,0 178,0
400069 4x(0,6/2,8) 14,1 65,0 214,0
400070 5x(0,6/2,8) 15,3 81,0 259,0
400071 6x(0,6/2,8) 16,7 97,0 295,0
400072 7x(0,6/2,8) 16,7 113,0 310,0

Dimensions and specifications may be changed without prior notice.

Application
The multi-core, coaxial HELUKABEL video cable is distinguished by 75 Ohm, cell PE insulation, AL foil and braided shielding, PVC element sheath
and outer sheath. Alternative we also offer a halogen-free and flame-resistant version. As example it is suitable for the parallel transmission of signals
(e.g. RGB).

792
Media Technology

Video
Camera cables

Type Camera Cables


Cable structure Triax 8
Conductor material: Copper, silvered
Core insulation: PE
Sheath material: PUR
Cable external diameter: approx. 8,5 mm
Sheath colour: red

Electrical data
Characteristic impedance: 75 Ohm

Technical data
Weight: approx. 95 kg/km
Min. bending radius for laying: 80 mm
Operating temperature range min.: -30C
Operating temperature range max.: +80C
Copper weight: 55,0 kg/km

Part no. Cable structure Conductor Outer diameter Cop. Weight


insulation approx. mm weight approx. kg / km
mm kg / km
400073 Triax 8 4,5 8,5 55,0 95,0
400074 Triax 11 6,5 11,0 80,0 150,0
400075 Triax 14 9,7 14,4 128,0 235,0
400076 Triax 8 flex 4,5 8,5 55,0 105,0
400077 Triax 11 flex 6,1 11,2 80,0 160,0
400078 Triax 14 flex 9,7 14,4 133,0 250,0

Dimensions and specifications may be changed without prior notice.

Application
The HELUKABEL Triax cable ensures the optimal transmission of image signals. This is possible because of the low attenuation values, thick cross-braided
shielding and an especially rugged outer sheath. For the Flex variant, the PVC inner and outer sheath are replaced by TPE to guarantee greater flexibility.
The Triax cables are primarily used to connect video cameras and image transmission systems and are suitable for mobile use.

793
RENEWABLE ENERGY & TRANSPORTATION

Cables for photovoltaic installations 796

Cables for wind turbines 802

Cables for aircraft supply 822

Cables for commercial vehicles 826

Cables for train & traffic 832

795
CABLES FOR PHOTOVOLTAIC INSTALLATIONS

Designation Properties Approvals Page

SOLARFLEX-X PV1-F 798

SOLARFLEX -X PV1-F NTS



799

SOLARFLEX -X PV1-F TWIN



800

797
Renewable Energy and Transportation / Cables for Photovoltaic Installations

SOLARFLEX-X PV1-F

Technical data Cable structure Properties


Temperature range Tinned copper-conductor, to Double-insulated
-40C to +90C DIN VDE 0295 cl.5, fine-wire, Ozone resistant acc. to EN 50396
max. temperature at conductor +120C IEC 60228 cl.5 Weather und UV resistant acc. to
Short circuit temperature Core insulation of cross-linked Polyolefin HD 605/A1
200C (short circuit duration up to 5 s) Core identification white Halogen-free acc. to DIN EN 50267-2-1,
Nominal voltage Outer sheath of cross-linked Polyolefin EN 60684-2
VDE 600/1000 V AC Sheath colour see table below Resistant to acid and bases acc. to EN
1800 V DC conductor/conductor with meter marking 60811-2-1
AC test voltage Flame retardant to DIN VDE 0482-332-1-2,
10000 V DIN EN 60332-1-2/ IEC 60332-1 (equivalent
Minimum bending radius DIN VDE 0472 part 804 test method B)
flexing 10x cable Very robust and abraison-resistant sheath
fixed installation 4x cable acc. to DIN EN 53516
Highest permissible Voltage Anticipated service life: 25 year
DC: Hydrolysis and ammoniac resistant
Conductor/Conductor 1,8 kV Approvals
Conductor/Earth 0,9 kV According to PV1-F requirement profile for
AC: Conductor/Earth 0,7 kV PV cable DKE / VDE AK 411.2.3
Three phase: Conductor/Conductor 1,2 kV VDE (Reg. 8266)
TV (2 PfG 1169 / 08.2007, R60025298)
UL certification in progress (UL Subject
4703)

Note
Not for direct installation in ground
Version with rodent protection available:
SOLARFLEX-X PV1-F NTS,
confer page 799

Application
The SOLARFLEX-X PV1-F is used for cabling solar modules.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Sheath Outer Cop. Weight AWG-No.


cross-sec. colour app. mm weight app. kg / km
mm kg / km
704225 1 x 2,5 black 4,5 24,0 42,0 14
705892 1 x 2,5 blue 4,5 24,0 42,0 14
705891 1 x 2,5 red 4,5 24,0 42,0 14
704226 1x4 black 5,2 38,4 60,0 12
705776 1x4 blue 5,2 38,4 60,0 12
705775 1x4 red 5,2 38,4 60,0 12
704227 1x6 black 5,9 57,6 82,0 10
705778 1x6 blue 5,9 57,6 82,0 10
705777 1x6 red 5,9 57,6 82,0 10
704228 1 x 10 black 6,9 96,0 123,0 8
705894 1 x 10 blue 6,9 96,0 123,0 8
705893 1 x 10 red 6,9 96,0 123,0 8
704229 1 x 16 black 8,3 153,6 190,0 6
706840 1 x 16 blue 8,3 153,6 190,0 6
706839 1 x 16 red 8,3 153,6 190,0 6
704230 1 x 25 black 10,0 240,0 285,0 4
704231 1 x 35 black 11,0 336,0 376,0 2
704232 1 x 50 black 13,0 480,0 530,0 1
704233 1 x 70 black 15,3 672,0 745,0 2/0
704234 1 x 95 black 17,0 912,0 960,0 3/0
705738 1 x 120 black 19,1 1152,0 1220,0 4/0
705739 1 x 150 black 22,7 1440,0 1550,0 300 kcmil
706288 1 x 185 black 25,5 1776,0 1930,0 350 kcmil
706289 1 x 240 black 28,3 2304,0 2550,0 500 kcmil

Dimensions and specifications may be changed without prior notice.

798
Renewable Energy and Transportation / Cables for Photovoltaic Installations

SOLARFLEX-X PV1-F NTS

Technical data Cable structure Properties


Temperature range Tinned copper-conductor, to Double-insulated
-40C to +90C DIN VDE 0295 cl.5, fine-wire, Approval: TV 2Pfg 1169/08.2007
max. temperature at conductor +120C IEC 60228 cl.5 UV-, ozone-resistant, weather-resistant
Short circuit temperature Core insulation of cross-linked Polyolefin Halogen-free
200C (short circuit duration up to 5 s) Core identification white Abrasion and cut resistant
Nominal voltage Outer sheath of cross-linked Polyolefin Relatively flexible
VDE 600/1000 V AC Sheath colour black Easy to strip
1800 V DC conductor/conductor Braiding of of stainless steel Flame-resistant according to
AC test voltage single V2A (rodent protection) DIN VDE 0482 Part 332-1-2, IEC 60332-1-2
10000 V Resistant to short circuits up to 200C
Minimum bending radius thanks to double insulation, short circuit
flexing 10x cable temperature 200C/5 sec.
fixed installation 4x cable Anticipated service life 25 years
Highest permissible Voltage
DC: Note
Conductor/Conductor 1,8 kV Further sizes are available on request.
Conductor/Earth 0,9 kV Not for direct installation in ground
AC: Conductor/Earth 0,7 kV
Three phase: Conductor/Conductor 1,2 kV

Application
The SOLARFLEX-X PV1-F NTS version with rodent protection, is used in PV systems mainly in farms and agricultural areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
706307 1x4 5,8 38,4 80,0 12 706309 1 x 10 7,5 96,0 152,0 8
706308 1x6 6,5 57,6 106,0 10

Dimensions and specifications may be changed without prior notice.

799
Renewable Energy and Transportation / Cables for Photovoltaic Installations

SOLARFLEX-X PV1-F TWIN

Technical data Cable structure Properties


Temperature range Tinned copper-conductor, to Double-insulated
-40C to +90C DIN VDE 0295 cl.5, fine-wire, Approval: TV 2Pfg 1169/08.2007
max. temperature at conductor +120C IEC 60228 cl.5 UV-, ozone-resistant, weather-resistant
Short circuit temperature Core insulation of cross-linked Polyolefin Halogen-free
250C (short circuit duration up to 5 s) Core identification black and red Abrasion and cut resistant
Nominal voltage Outer sheath of cross-linked Polyolefin Relatively flexible
VDE U0/U 600/1000 V AC Sheath colour black Easy to strip
1800 V DC conductor/conductor Flame-resistant acc. to DIN VDE 0482
AC test voltage part 332-1-2, IEC 60332-1-2
6500 V, 50 Hz, 15 kV DC Anticipated service life 25 years
Minimum bending radius
flexing 10x cable Note
fixed installation 4x cable Further sizes are available on request.
Highest permissible Voltage Not for direct installation in ground
DC:
Conductor/Conductor 1,8 kV
Conductor/Earth 0,9 kV
AC: Conductor/Earth 0,7 kV
Three phase: Conductor/Conductor 1,2 kV

Application
The SOLARFLEX-X PV1-F TWIN is used for cabling solar modules.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight app. kg / km cross-sec. dimension weight app. kg / km
mm app. mm kg / km mm app. mm kg / km
707234 2 x 2,5 5,4 x 11,0 50,0 95,0 14 705769 2x6 6,8 x 13,6 120,0 187,0 10
707235 2x4 5,8 x 11,8 80,0 125,0 12 707236 2 x 10 7,8 x 15,8 200,0 254,0 8

Dimensions and specifications may be changed without prior notice.

800
802
CABLES FOR WIND TURBINES

Designation Properties Approvals Page

HELUWIND WK 103w EMV D-T


UV-resistant, UL/CSA style 10678/21179 single-core/multicore 808

HELUWIND WK 103k EMV D-T UV-resistant, UL/CSA style 10269/2570 single-core/multicore 809
UV-resistant, UL/CSA style** 10553 / 20234, single-core/multicore 90C
HELUWIND WK 135-Torsion 810
(80C in accordance with UL), suitable for offshore

UV-resistant, suitable for offshore, UL/CSA style 10553/20234,


HELUWIND WK 137-Torsion 811
single-core/multicore, 90C (80C in accordance with UL)

HELUWIND WK 300w-Torsion UV-resistant, also suitable for direct burial 812

HELUWIND WK 310-Torsion
UV-resistant, suitable for offshore 813

HELUWIND WK H07BN4N4-F WIND-Torison Torsion +/- 150/1m, UV-resistant, 750V/90C 814

HELUWIND WK 101 H
0.6/1 kV halogen-free 815

HELUWIND WK fire alarm cable Torsion Halogen-free, FT1, 24V 816

HELUWIND WK DLO 2kV


FT4, UV-resistant, UL44 1kV, 90C, VW-1, LS, MSHA 817

HELUWIND WK Powerline ALU 0.6/1 kV or 1.8/3kV, each also available as robust version 818

HELUWIND THERMFLEX 145


Halogen-free, +145C 819

WK (N)A2XH 0.6/1 kV, halogen-free 820

803
FUNCTION VIEW - WIND TURBINES

Rotor blade
Gearbox Nacelle
Brake

Generator

Yaw control

Rotor hub &


blade adjustment

Tower

Cables and lines


For use in:

Nacelle
Cable loop
Tower
Tower control system / transformer
Tower base Tower control system / transformer

Medium-voltage level

Foundation

804
SELECTION TABLE - CABLES & WIRES

ce

e
nc
an

da

C
rd

or
co

in
cc
2)

ac

n
t
a

an

tio
U al v h FT

in

ist
i

la

/-
C
ge

ho an res

al
ag
it

+
ic

in
ta

st
(w

V- ve **
E olt

ffs st il-
h

Cu eter ble
in
ol

g
ap

O si o

e
re t
4

n
VD al v

fre

U si nt

ed

a
us

xi
gr

re ly
T

r m on

n
te sta

fle
il- -

fix
F

ith in

ith in

ee
al

O g en
ee

pe rsi
st

st

L
ov

Ex si
w om

w om

cr
p.

p.
,s

te

te

e
n

To

ge
pr

-s
lo

m
N

N
se

e
Ap

Ha

Pa
Fir

Fir

Te

Te
U

Torsion cables
UL 10678/
WK 103w-T 21179, x 1000 V 0.6/1 kV x* x x -40 to +90 -35 to +90 140 808
cRUus, CE
UL 10269,
WK 103w EMV D-T 2570, cRUus, x 1000 V 0.6/1 kV x* x x -40 to +90 -35 to +90 90 808
CE
UL 10269,
WK 103k-T 2570, cRUus, x 1000 V 0.6/1 kV x x -40 to +80 -40 to +80 140 809
CE
UL 10269,
WK 103k EMV D-Torsion 2570, cRUus, x 1000 V 0.6/1 kV x x -40 to +80 -40 to +80 90 809
CE
UL 10553,
WK 135-T 20234, cRUus, 60332-3 1000 V 0.6/1 kV x x x x -40 to +90 -40 to +90 150 810
CE, VDE
UL 10553,
WK 135 EMV D-T 20234, cRUus, 60332-3 1000 V 0.6/1 kV x x x x -40 to +90 -40 to +90 150 810
CE, VDE
UL 10553,
WK 137-T FT4 20234, cRUus, x1 1000 V 0.6/1 kV x x x x -40 to +90 -40 to +90 150 811
CE, VDE
UL 10553,
WK 137 EMV D-T 20234, cRUus, x1 1000 V 0.6/1 kV x x x x -40 to +90 -40 to +90 150 811
CE, VDE
WK 300w-T CE 1.8/3kV x x -40 to +90 -35 to +90 90 812
WK 310-T CE 30332-3 1.8/3kV x x x -40 to +90 -40 to +90 150 813
WK H07BN4-F WIND-T CE 450/750V x -45 to +90 -35 to +90 150 814
WK 101 H CE 0.6/1 kV x x x -50 to +100 -40 to +90 815
WK fire alarm cable-T CE x 24V x x -50 to +90 -40 to +80 215 816
WK NTSCGEWOEU-T CE 3.6/6kV x x -40 to +90 -40 to +90 100 ???
WK DLO 2 kV UL 44, CSA, CE x x 2000 V x -40 to +90 817
WK Powerline ALU 60332-3 0.6/1 kV x x x -40 to +105 -20 to +105 818
WK THERMFLEX 145 CE 0.6/1 kV x x -55 to +145 -20 to +120 819
WK (N)A2XH CE 60332-3 0.6/1 kV x x -30 to +90 -5 to +50 820
Tower & infrastructure cables
NYY-J/-0 CE x 0.6/1 kV -40 to +70 -5 to +50 538
NAYY CE x 0.6/1 kV -40 to +70 -5 to +50 544
NA2XY CE x 0.6/1 kV -40 to +70 -5 to +50 551
N2XH CE x 0.6/1 kV x -30 to +90 -5 to +50 ???
WK (N)A2XH CE 60332-3 0.6/1 kV x x -40 to +90 -5 to +50 820
N2XS2Y 6-30 kV x -40 to +90 x 587
NA2XS2Y 6-30 kV x -40 to +90 x 595
N2XS(F)2Y 6-30 kV x -40 to +90 x 589 T
NA2XS(F)2Y 6-30 kV x -40 to +90 x 597

x1 for multicore types *in preparation **based on UL 1277

805
SELECTION TABLE - CABLES & WIRES

ce

e
1

nc
2-

an

da
33

C
rd

or
60

co

in
cc
ac

n
nt
C

tio
IE

ta
in

in

la
sis
o

C
e

ge
st

al
g

re
ic

in
ta

st
d

E olt

-
h

in
on

ol

ng
ap

oi
ns ee

nt
U al v

VD al v

ed
sp

xi
gr

ly

ta
Ex n-f

n
fle
fix
rre

ive
ith in

ith in
al

ee
sis
ee

L
ov

w om

w om

ge
co

cr
p.

p.
re
,s

ge
pr

-s
lo

te

m
V-
N

N
se

1
Ap

Ha

Cu

Pa
FT

Te

Te
U

U
Control cables
JZ-500 CE, VDE x 300/500 V x -40 to +80 -15 to +80 30
F-CY-JZ CE, VDE x 300/500 V x -40 to +80 -40 to +80 50
Y-CY-JZ CE, VDE x 300/500 V -40 to +80 -5 to +80 x 53
JZ-500 HMH CE 60332-3 300/500 V x -40 to +70 -15 to +70 x 86
JZ-500 HMH-C CE 60332-3 300/500 V x -40 to +70 -15 to +70 x 96
MEGAFLEX 500 UL, CSA, CE 60332-3 300/600 V 300/500 V x x x -40 to +80 -30 to +90 x 88
MEGAFLEX 500-C UL, CSA, CE 60332-3 300/600 V 300/500 V x x x -40 to +80 -30 to +90 x 98
JZ-600 CE x 0.6/1 kV x x -40 to +80 -5 to +80 x 40
JZ-600-Y-CY CE x 0.6/1 kV x x -40 to +80 -5 to +80 x 60
Single 600-J/-O UL, CSA, CE x 600 V 0.6/1 kV x -40 to +90 -5 to +90 x 498
Single 600-CY -J/-O UL, CSA, CE x 600 V 0.6/1 kV x -40 to +90 -5 to +90 x 499
JZ-600 HMH CE 60332-3 0.6/1 kV x x x -40 to +70 -15 to +70 x 91
JZ-600 HMH-C CE 60332-3 0.6/1 kV x x x -40 to +70 -5 to +70 x 100
JZ-600 UL/CSA UL, CSA, CE x 1kV 0.6/1 kV x in sw -40 to +80 -5 to +80 x 362
JZ-600-Y-CY-UL/CSA UL, CSA, CE x 1kV 0.6/1 kV x in sw -40 to +80 -5 to +80 x 378
JZ-602 UL, CSA, CE x 600 V x -40 to +90 -5 to +90 x 356
JZ-602-CY UL, CSA, CE x 600 V x -40 to +90 -5 to +90 x 373
UL, CSA,
JZ-603 x 600 V 300/500 V x -40 to +70 -5 to +70 x 358
CE, HAR
UL, CSA,
JZ-603-CY x 600 V 300/500 V x -40 to +70 -5 to +70 x 375
CE, HAR
UL, CSA,
H07RN-F 600 V 450/750 V x -40 to +90 242
CE, HAR
UL, CSA,
H07RN-F/SOOW 600 V 450/750 V x -40 to +90 481
CE, HAR
HELUTHERM 145 MULTI CE 60332-3 300/500 V x x x -55 to +145 -35 to +120 x 221
HELUTHERM 145 MULTI/-C CE 60332-3 450/750 V x x x -55 to +145 -35 to +120 x 230
Data lines
TRONIC-CY CE x 350/500V x -40 to +80 -5 to +80 x 133
PAAR-TRONIC-CY CE x 350/500V x -30 to +80 -5 to +80 x 135
DATAFLAMM CE x 350/500V x -40 to +70 -5 to +70 x 130
DATAFLAMM-C CE x 350/500V x -40 to +70 -5 to +70 x 147
DATAFLAMM-C-PAAR CE x 350/500V x -40 to +70 -5 to +70 x 148
LIYY-UL UL, CSA, CE 300V x -20 to +80 -10 to +80 x 403
LIYY-TP-UL UL, CSA, CE 300V x -20 to +80 -10 to +80 x 407
SUPERTRONIC-PUR CE 350V x -40 to +70 -5 to +70 x 191
SUPERTRONIC-C-PUR CE 350V x -40 to +70 -5 to +70 x 192
SUPERTRONIC -330 PUR

UL, CSA, CE x 300V 300V x x -50 to +80 -40 to +80 x 447
SUPERTRONIC-330-C-PUR UL, CSA, CE x 300V 300V x x -50 to +80 -40 to +80 x 449
SUPER-PAAR-TRONIC-C-PUR UL, CSA, CE x 300V 350V x x -50 to +70 -40 to +70 x 193
SUPER-PAAR-TRONIC 340-C-PUR UL, CSA, CE x 300V 350V x x -50 to +70 -40 to +70 x 451

806
SELECTION TABLE - CABLES & WIRES

ce

e
1

nc
2-

an

da
33

C
rd

or
60

co

in
cc
ac

n
nt
C

tio
IE

ta
in

in

la
sis
o

C
e

ge
st

al
g

re
ic

in
ta

st
d

E olt

-
h

in
on

ol

ng
ap

oi
ns ee

nt
U al v

VD al v

ed
sp

xi
gr

ly

ta
Ex n-f

n
fle
fix
rre

ive
ith in

ith in
al

ee
sis
ee

L
ov

w om

w om

ge
co

cr
p.

p.
re
,s

ge
pr

-s
lo

te

m
V-
N

N
se

1
Ap

Ha

Cu

Pa
FT

Te

Te
U

U
Single cores
H07 V-K/(H)07 V-K CE x x -30 to +80 -5 to +70 291
H05Z-K/H07Z-K CE x x -40 to +90 -5 to +70 300
FIVE APPROVAL UL, CSA, CE x x -40 to +90 -5 to +90 490
HELUTHERM 145 600V UL, CSA, CE x x -55 to +125 -35 to +120 305
HELUTHERM 145 600V UL UL, CSA, CE x x -55 to +125 -35 to +120 496
TC TRAY CABLES USA
TRAYCONTROL 300 UL, CSA, CE FT 4 300V x -25 to +105 -25 to +105 405
TRAYCONTROL 300-C
UL, CSA, CE FT 4 300V x -25 to +105 -25 to +105 x 416
TRAYCONTROL 300-C TP UL, CSA, CE FT 4 300V x -25 to +105 -25 to +105 x 420
UL 1277,
TRAYCONTROL 500 FT 4 1000V x -40 to +90 -5 to +90 359
CSA, CE
UL 1277,
TRAYCONTROL 500-C FT 4 1000V x -40 to +90 -5 to +90 x 376
CSA, CE
UL 1277,
JZ-604 TC TRAY CABLE FT 4 600V x x -25 to +90 -5 to +90 364
CSA, CE
JZ-604-YCY TC TRAY CABLE UL 1277, CSA FT 4 600V x x -25 to +90 -5 to +90 x 381
UL 1277,
TRAYCONTROL 600
FT 4 1000V x x -40 to +90 -5 to +90 366
CSA, CE
Communication cables
Industrial Ethernet 105C UL, CSA, CE 60332-1 300V 100V x x x -40 to +105 -40 to +105 x 693
Industrial Ethernet
UL, CSA, CE 60332-1 300V 100V x x x -20 to +80 -20 to +80 x 697
S-FTP TORDIERFLEX
BUS cable HELUWIND
UL, CSA, CE x 600V 100V x x x -40 to +105 -20 to +60 x ???
WK CAN BUS 105C
BUS cable Indoor UL, CSA, CE x 600V 100V x -40 to +70 -5 to +60 x 717
Profibus SK Outdoor CE 100V x x -40 to +70 -5 to +60 x 717
BUS cable Torsion UL, CMX, CE x 300V 100V x x x -40 to +75 -25 to +75 x 704
Profibus L2 Industry CE x 100V x x x -40 to +70 -5 to +60 x 706
AT-V(ZN)Y(ZN)Y Submitted Submitted x x -40 to +90 -40 to +90 638
AT-V(ZN)H(ZN)11Y x x x -40 to +90 -40 to +90 638
Fiber-optic cable, mobile,
easy-to-wind 60332-1 x x x -30 to +70 -20 to +70 636
A-V(ZN)11Y
Fiber-optic cable mobile
UL, CSA FT4 x x -30 to +80 -20 to +80 637
A-V(ZN)Y
Fiber optic breakout cable
UL, CSA FT4 x x -30 to +85 -20 to +85 644
Industry HCS I-V(ZN)YY
Fiber optic breakout cable
x x -20 to +80 -20 to +80 645
Industry HCS I-V(ZN)Y11Y
Plastic fiber cable Industry
60332-1 x x -20 to +80 -20 to +80 648
POF/PE I-V2Y, I-V2Y(ZN)11Y
Fiber optic universal cable
T
60332-1 x x x -20 to +60 -5 to +50 613
A/I-DQ(ZN)BH
Fiber optic outdoor cable
x -20 to +60 -5 to +50 619
A-DQ(ZN)B2Y (central)
Fiber optic outdoor cable
x -20 to +60 -5 to +50 620
A-DQ(ZN)B2Y (stranded)
Fiber optic outdoor cable
A-DQ(ZN)B2Y x -20 to +60 -5 to +50 625
(Stranded, fiber combination)

807
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK 103w-T,
WK 103w EMV D-T UV-resistant, UL/CSA-Style 10678/21179
Single-/Multicore

Technical data Cable structure Properties


Temperature range Special bare copper conductors, fine stranded UV-resistant
flexing -35C to +90C acc. to IEC 60228 multi-climate operation
fixed installation -40C to +90C Special heat-resistant insulation torsion tested
installation -20C to +90C Core identification JZ: black with white flame-retardant
Operating temperature at conductor numbers + GN-YE conductor oil-resistant
max. +90C Multiconductors cabled recyclable
Nominal voltage Sheath special heat-resistant compound easy to assemble
VDE U0/U 0,6/1 kV Black sheath
UL 1000 V Note
Test voltage Other diameters, part-no. and prices on request.
core/core 4000 V Please contact us with your individual
Minimum bending radius requirements via
flexing 8x cable fax +49 7150 9209 5135.
fixed installation 4x cable Highest permissible Voltage
Torsion application DC:
+/-140 per 1m Conductor/Conductor 1,8 kV
Approvals Conductor/Earth 0,9 kV
Singlecore UL-Style 10678 AC: Conductor/Earth 0,7 kV
Multicore UL-Style 21179 Three phase: Conductor/Conductor 1,2 kV
cRUus
Flame test
FT1, VW-1, IEC 60332-1

Application
The WK 103w has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The voltage level has been
configured as 0. 6/1 kV for all dimensions, which means that the cables can also be laid in parallel in compliance with UL standards. It is no longer
necessary to separate the cable routes. The WK series has been successfully tested with more than 18,000 torsion cycles and thus offers optimum
operational reliability far beyond the service life of the wind power plant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.

808
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK 103k-T, WK 103k EMV D-T


UV-resistant, UL/CSA-Style 10269/2570 Single-/Multicore, screened/unscreened

Technical data Cable structure Properties


Temperature range Special bare copper conductors, UV-resistant
flexing -40C to +80C fine stranded acc. to IEC 60228 multi-climate operation
fixed installation -40C to +80C Special flexible insulation material torsion tested
installation -40C to +80C for low temperatures flame-retardant
Nominal voltage Core identification to DIN 47100 oil-resistant
VDE U0/U 0,6/1 kV JZ: black with white numbers + recyclable
UL 1000 V GN-YE conductor easy to assemble
Test voltage Multiconductors cabled
core/core 4000 V Sheath special heat-resistant compound Note
Minimum bending radius Sheath colour black Other diameters, part-no. and prices on request.
flexing 8x cable Please contact us with your individual
fixed installation 4x cable requirements via
Torsion application fax +49 7150 9209 5135.
+/-140 per 1 m Highest permissible Voltage
Approvals DC:
Singlecore UL-Style 10269 Conductor/Conductor 1,8 kV
Multicore UL-Style 2570 Conductor/Earth 0,9 kV
cRUus AC: Conductor/Earth 0,7 kV
Flame test Three phase: Conductor/Conductor 1,2 kV
FT1, VW-1, IEC 60332-1

Application
The WK 103k has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The voltage level has been
configured as 0. 6/1 kV for all dimensions, which means that the cables can also be laid in parallel in compliance with UL standards. It is no longer
necessary to separate the cable routes. The WK series has been successfully tested with more than 18,000 torsion cycles and thus offers optimum
operational reliability far beyond the service life of the wind power plant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC..
Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable lug

809
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK 135-T,
WK 135 D-EMV T UV-resistant, UL/CSA-Style** 10553
/ 20234, Single-/Multicore 90C (80C acc. to UL), suitable for offshore

Technical data Cable structure Properties


Temperature range Special bare copper conductors, fine stranded halogen-free
flexing -40C to +90C acc. to IEC 60228 extremely abrasion-resistant
fixed installation -40C to +90C Insulation special compound low adhesion
UL +80C Core identification high flame retardant
Operating temperature at conductor JZ: black with white numbers + GN-YE torsion testet
max. +90C conductor suitable for Offshore
Nominal voltage or colour code DIN 47100 or VDE 0293 HD extremely oil resistant
VDE U0/U 0,6/1 kV 308 UV-resistant
UL 1000 V Multiconductors cabled recyclable
Test voltage Sheath special compound multi climate operation
core/core 4000 V Black sheath designed for CCV application
Minimum bending radius easy to assemble
flexing 8x cable
fixed installation 4x cable Note
Torsion application Other diameters, part-no. and prices on request.
+/-150 per 1m Please contact us with your individual
Approvals requirements via
Singlecore UL-Style 10553 fax +49 7150 9209 5135.
Multicore UL-Style 20234 Highest permissible Voltage
cRUus DC:
Flame test Conductor/Conductor 1,8 kV
FT1, IEC 60332-3-24 Conductor/Earth 0,9 kV
UL 758, Cable flame test AC: Conductor/Earth 0,7 kV
Halogen free Three phase: Conductor/Conductor 1,2 kV
IEC 60754-1
Smoke density
IEC 61034-1+2
Oil
acc. to oil res II
WTTC in preparation

Application
The WK 135 has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The voltage level has been
configured as 0. 6/1 kV for all dimensions, which means that the cables can also be laid in parallel in compliance with UL standards. It is no longer
necessary to separate the cable routes. Thanks to its highly durable sheath and absence of halogen, this cable is ideal for use in offshore wind power
plants. The WK series has been successfully tested with more than 18,000 torsion cycles and thus offers optimum operational reliability far beyond
the service life of the wind power plant. Advantages of WK 135-T over H07BN4-F: Fire behaviour in accordance with IEC 60332-3-24 Increased
wear resistance Recyclable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.

810
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK 137-T /
WK 137 EMV D-TFT 4 UV-resistant, suitable for
offshore, UL/CSA-Style 10553/20234, Single-/Multicore, 90C, (80C
according to UL)

Technical data Cable structure Properties


Temperature range Special bare copper conductors, fine stranded halogen-free
flexing -40C to +90C acc. to IEC 60228 extremely abrasion-resistant
fixed installation -40C to +90C Insulation special compound low adhesion
acc. UL to +80C Core identification high flame retardant
Operating temperature at conductor JZ: black with white numbers + torsion testet
max. +90C GN-YE conductor or colour code DIN 47100 suitable for Offshore
Nominal voltage Multiconductors cabled extremely oil resistant
VDE U0/U 0,6/1 kV Sheath special compound SSH UV-resistant
UL 1000 V Black sheath multi climate operation
Test voltage designed for CCV application
core/core 4000 V easy to assemble
core/shield 2000 V
Minimum bending radius Note
flexing 8x cable Other diameters, part-no. and prices on request.
fixed installation 4x cable Please contact us with your individual
Torsion application requirements
+/-150 per 1m via fax +49 7150 9209 5135.
Approvals Highest permissible Voltage
Singlecore UL-Style 10553 DC:
Multicore UL-Style 20234 Conductor/Conductor 1,8 kV
cRUus Conductor/Earth 0,9 kV
Flame test AC: Conductor/Earth 0,7 kV
FT 4 Three phase: Conductor/Conductor 1,2 kV
IEC 60332-3-24
UL 758, Cable flame test
Halogen free
IEC 60754-1
Smoke density
IEC 61034-1+2
Oil
acc. to oil res II
WTTC in preparation

Application
The WK 137 has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The voltage level has been
configured as 0. 6/1 kV for all dimensions, which means that the cables can also be laid in parallel in compliance with UL standards. It is no longer
necessary to separate the cable routes. Additionally, this cable meets the strict requirements of CSA flame test FT4 and, thanks to its highly durable
sheath and absence of halogen, is ideal for use in offshore wind power plants. The WK series has been successfully tested with more than 18,000
torsion cycles and thus offers optimum operational reliability far beyond the service life of the wind power plant. Advantages of WK 137-T FT4 over
H07BN4-F: Fire behaviour in accordance with IEC 60332-3-24 and FT4 Increased wear resistance
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.

T
Suitable accessories can be found in Chapter X.
Cable lug

811
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK 300w-Torsion 1,8/3kV UV-resistant,


also suitable for underground laying

Technical data Cable structure Properties


Temperatur range Special bare copper conductor, fine stranded UV-resistant
flexing -35C to +90C acc. to IEC 60228 multi-climate operation
fixed installation -40C to +90C Special heat-resistant insulation black torsion tested
installation -20C to +90C Sheath special heat-resistant compound flame-retardant
Operating temperature at conductor Black sheath oil-resistant
max. +90C recyclable
Nominal voltage easy to assemble
VDE U0/U 1,8/3 kV also for direct burial
Test voltage
9000 V Note
Minimum bending radius Other diameters, part-no. and prices on request.
flexing 10x cable Please contact us with your individual
fixed installation 5x cable requirements via
Torsion application fax +49 7150 9209 5135.
+/-100 per 1m for unscreened version
Flame test
FT1, VW-1, IEC 60332-1
flame retardant and self-extinguishing

Application
The WK 300w has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The WK series has been
successfully tested with more than 18,000 torsion cycles and thus offers optimum operational reliability far beyond the service life of the wind power
plant. Another special feature is the higher voltage level of 1.8/3 kV. The WK 300w is also designed for flexible installation through ductwork and in
the ground. It can be used in power cabling from a converter cabinet to an external transformer station, for example. A conductor temperature of
+90 enables a high level of current carrying capacity.
Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable lug

812
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK 310-Torsion 1,8/3kV


UV-resistant, suitable for offshore

Technical data Cable structure Properties


Temperature range Special bare copper conductor, fine stranded halogen free
flexing -40C to +90C acc. to IEC 60228 extremely abrasion resistant
fixed installation -40C to +90C Special insulation black low adhesion
Operating temperature at conductor Sheath SSH compound low adhesion high flame retardant
max. +90C Black sheath torsion testet
Nominal voltage suitable for offshore
VDE U0/U 1,8/3 kV extremely oil resistant
Test voltage UV resistant
9000 V recyclable
Minimum bending radius Multi climate operation
flexing 10x cable designed for CCV application
fixed installation 5x cable easy to assemble
Torsion application
+/-100 per 1m Note
Flame test Other diameters, part-no. and prices on request.
IEC 60332-3, FT2 Please contact us with your individual
Halogen free requirements via
IEC 60754-1 fax +49 7150 9209 5135.
Smoke density
IEC 61034-1+2
Oil test
acc. to oil res II

Application
The WK 310 has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The WK series has been
successfully tested with more than 18,000 torsion cycles and thus offers optimum operational reliability far beyond the service life of the wind power
plant. Another special feature is the higher voltage level of 1.8/3 kV. The WK 310 can be used instead of the WK 300 in cases where cables need to
be halogen-free.
Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable lug

813
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK H07BN4-F WIND-Torsion


Torsion +/- 150/1m, UV-resistant, 750 V/90C

Technical data Cable structure Properties


Temperature range Special bare copper conductors, fine stranded UV-resistant
Ambient temperature -45C to +90C acc. to IEC 60228
Operating temperature at conductor Insulation Special EPR compound black Note
max. +90C Sheath Special EPR compound Other diameters, part-no. and prices on request.
Nominal voltage colour black Please contact us with your individual
450/750 V requirements via
Test voltage fax +49 7150 9209 5135.
3000 V
Minimum bending radius
6x cable
Torsion application
+/-150 per 1m

Application
The HELUWIND WK H07BN4-F Wind-Torsion cable is the special version for torsion applications in wind power plants. We supply the leading wind
power plant manufacturers with our cables.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable lug

814
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK 101 H 0,6/1kV halogen-free

Technical data Cable structure Properties


Temperature range Special bare copper conductors, halogen-free
flexing -40C to +90C fine stranded acc. to IEC 60228 abrasion-resistant
fixed installation -50C to +100C Seperarting foil wrap extremely oil resistant
acc. to UL +80C Insulation special compound black UV and ozone resistant
Operating temperature at conductor Sheath special compound recyclable
max. +90C Sheath colour black multi climate application
Nominal voltage
VDE U0/U 0,6/1 kV Note
Test voltage Other diameters, part-no. and prices on request.
4000 V Please contact us with your individual
Minimum bending radius requirements via
flexing 7,5x cable fax +49 7150 9209 5135.
fixed installation 4x cable A torsional version for loop application
Halogen free is available on request.
IEC 60754-1 Highest permissible Voltage
DC:
Conductor/Conductor 1,8 kV
Conductor/Earth 0,9 kV
AC: Conductor/Earth 0,7 kV
Three phase: Conductor/Conductor 1,2 kV

Application
The HELUWIND WK series has been specifically designed for use in wind power plants. These cables are used in cases that require extremely narrow
bending radii and high current carrying capacity levels (+90C conductor temperature).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC..
Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable lug

815
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK Fire Alarm Cable-Torsion


halogen-free, FT1, 24V

Technical data Cable structure Properties


Temperature range Special bare copper conductors, very good oil and petrol-resistance acc. to DIN
flexing -40C to +80C fine stranded acc. to IEC 60228 VDE 0250 and 0472
fixed installation -50C to +90C Special Polyester insulation good resistance to acids, alkalis and solvents
Nominal voltage Core identification (OZ) black with numbers
300/500 V 1-_ Note
Test voltage Multiconductors cabled Other diameters, part-no. and prices on request.
core/core 1500 V EMV-shielded types have tinned copper Please contact us with your individual
core/shield 800 V wrapping requirements via
Minimum bending radius Sheath special polyurethane compound low fax +49 7150 9209 5135.
10x cable adhesion
Torsion application Sheath colour red RAL 3000
3 x 360 on 5m (= 216 je m)
Approvals
IEC 60332-1, test type B acc. to VDE 0472
Part 804,
Flame test
FT1

Application
This fire alarm cable has been specifically developed for torsion applications in wind power plant loops. We supply the leading wind power plant
manufacturers with our cables.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable lug

816
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK DLO 2kV FT4, UV-resistant, UL44


1kV, 90C, VW-1, LS, MSHA

Technical data Cable structure Properties


Temperature range Tinned copper conductors acc. to UV-resistant
flexing -40C to +90C ASTM B-172, ASTM B-33
Nominal voltage Special wrapping Note
DLO 2000 V Special EPR insulation Other diameters, part-no. and prices on request.
Approvals Special CPE sheath compound, non-adhesive Please contact us with your individual
UL44, CSA, ICEA S-68-516/NEMA WC-8, Sheath colour black requirements via
MSHA, VW-1, FOR CT USE. LS CERTIFIED fax +49 7150 9209 5135.
Flame test
FT4, FT1

Application
The cable is UL 44 listed. The WK DLO is a flexible cable for continuous tower cabling in wind power plants, right up to the topmost tower segment.
For the torsion cable through the cable loop to the generator in the nacelle, we recommend the WK 103 or WK 135.
Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable lug

817
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK Powerline ALU 105C 0,6/1kV or 1,8/3kV, also


available as a robust version

Technical data Cable structure Properties


Temperature range Aluminium conductor, fine stranded wires UV resistant
flexing -20C to +90C Special insulation black oil-resistant
fixed installation -40C to +105C Sheath special compound easy to assemble
Operating temperature at conductor black sheath recyclable
max. +105C
Nominal voltage Note
0,6/1 kV Please ask for our extended notes/information
Test voltage about the properties and for the necessary
2,5 kV connection technology.
Minimum bending radius Please contact us with your individual
flexing 10x cable requirements via
fixed installation 4x cable fax +49 7150 9209 5135.
Flame test
IEC 60332-1
Approvals
acc. to DIN VDE 0250-813
UL/CSA in preparation

Application
The WK Powerline ALU is a highly flexible aluminium cable with a finely stranded structure and is designed for use in the power engineering sector;
specifically, for power cabling in wind power plants. Thanks to its high degree of flexibility and low tare weight, this cable can be fed into the tower
as a single length. This eliminates the need for time-consuming cabling of each individual tower segment. However, its key advantage lies in the process
reliability the connection technology offers: using this cable can reduce the number of interruptions between the topmost tower segment and the
converter from 90 connection points to just 18 (depending on the number of power cables and tower segments). As a result, the amount of time
required for installation can drop from several days to a few hours. For torsion applications, we recommend the WK 103-T, WK 135-T or WK 137-T.
The WK Powerline ALU may only be used with certified connection technology from HELUKABEL: either C8 crimp connections or screwed connections
(tested in accordance with IEC 61238-1 Cl. A). See the accessories section of the catalogue. The cable is also available with a halogen-free design,
UL/CSA approval or a rated voltage of 1. 8/3 kV.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.

818
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK THERMFLEX 145 halogen-free, +145C

Technical data Cable structure Properties


Temperature range Tinned copper conductors, fine stranded acc. Halogen-free, no release of corrosive or toxic
flexing -20C to +120C to IEC 60228 cl.5 gases
fixed installation -55C to +145C Insulation special polyolefin-copolymer, Reduced propagation of fire
Nominal voltage halogen-free, flame retardant Minimal smoke generation
U0/U 0,6/1 kV Sheath colour black Good abrasion-resistance
Test voltage Good oil and weathering resistance
4000 V Resistant to UV radiation and ozone
Insulation resistance Thermal class B
min. 100 MOhm x km easy to assemble
Minimum bending radius The materials used are silicone and
flexing 12,5x cable cadmium-free and free of substances harmful
fixed installation 4x cable to paint adhesion
Flame test
IEC 60332-3-24 Cat. C Note
Other diameters, part-no. and prices on request.
Please contact us with your individual
requirements via
fax +49 7150 9209 5135.
Highest permissible Voltage
DC:
Conductor/Conductor 1,8 kV
Conductor/Earth 0,9 kV
AC: Conductor/Earth 0,7 kV
Three phase: Conductor/Conductor 1,2 kV

Application
This special cable can be used as a generator connecting cable in wind power plants, for example. Other areas of application: Connecting cable for
temperature class B (130C) in the case of motors, transformers, relays, coils, magnets, and so onUnit connections in the automotive industry.
Halogen-free wiring of switchgear and control cabinets. Connecting cable for heating equipment. Supply line for high-power lighting in industry,
sports centres and street lighting
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable lug

819
Renewable Energy and Transportation / Cables for Wind Turbines

HELUWIND WK (N)A2XH 0,6/1kV, halogen-free

Technical data Cable structure Properties


Temperature range ALU conductors, stranded conductors acc. to Halogen-free
fixed installation -40C to +90C IEC 60228 Cl. 2 UV resistant
during assembly -5C to +50C core insulation cross-linked PE
Operating temperature at conductor Core identification black Note
max. +90C Sheath thermoplastic polymer Other diameters, part-no. and prices on request.
Nominal voltage black sheath Please contact us with your individual
U0/U 0,6/1 V requirements via
Test voltage fax +49 7150 9209 5135.
4 kV
Approvals
production in according to VDE standards,
CE compliant
Minimum bending radius
15 x cable
Flame test
acc. to DIN VDE 0482 part 266-2,
BS 4066 part 3, EN 50266-2,
IEC 60332-3-24 (equivalent
DIN VDE 0472 part 804 cat. C)
Smoke density
acc. to DIN VDE 0482 part 268, HD 606,
EN 50268-12, IEC 61034-1-2,
BS 7622 Teil 12 (equivalent
DIN VDE 0472 Teil 816)
Corrosivity of combustion gases
acc. to VDE 0482 Teil 267,
DIN EN 50267-2-2, IEC 60754-2
(equivalent DIN VDE 0472 part 813)
Halogen free
acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)

Application
The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.

Suitable accessories can be found in Chapter X.


Cable lug

820
Cavotec
CABLES FOR AIRCRAFT SUPPLY

Designation Properties Page

AIRPORT 400 Hz easy-to-wind, PUR, halogen-free, flame-retardant 824

AIRPORT 400 Hz PUR, halogen-free, flame-retardant 825

823
Renewable Energy and Transportation / Cables for Aircraft feeder lines

AIRPORT 400 Hz trailing, PUR, halogen-free, flame retardant

Technical data Cable structure Properties


Temperature range Fine copper wire in acc. with Low adhesion, abrasion resistant,
-40C to +90C DIN VDE 0295 and IEC 60228 halogen-free, resistant to UV-, oil-,
Nominal voltage Core insulation PP, black hydrolysis and microbial attack
115/200 V with number 1-6 + blue/..., Special feature:
Operating voltage with number 7-30/1 mm The use of four-core cables to transmit large
U0/U 0,6/1 kV 4 cores each 1 mm twisted to a quad amounts of power in a 400 Hz grid results in
Test voltage Cores and 6 bundles laid-up together voltage asymmetries and larger inductive
4000 V PUR inner sheath voltage losses. These unfavourable cable
Minimum bending radius Support braiding characteristics can be improved through the
flexing 7x cable PUR outer sheath, orange (RAL 2003) employment of seven-core cables. In this
fixed installation 4x cable Part no. 702801 case the central core is used as a earth conductor
Bare copper conductor, 7 strands (blue) and six cores with the same cross-section
Core insulation cross-linked polyethylene, (black with imprint) stranded in a single layer
black with number 1-6 + blue around the central core. Each pair of two
Polyethylene inner sheath opposite cores is connected in parallel to a phase
Concentric conductor of plain Cu wires, conductor.
cross-section 35 mm
Black polyehtylene outer sheath Note
Distribution only over authorised partner

Application
400 Hz cables are used to supply power to aircraft (on-board power), data processing systems, radar stations, radio stations, etc. For safety reasons,
400 Hz cables are used to connect data processing systems, radar systems and communications systems to uninterruptible power supplies. Such
power supplies prevent a total failure of power and compensate for frequency and voltage fluctuations. Suitable for installation indoors, outdoors.
Applications: Below floor level cable dispensers (drums), attached to jetways and retractable articulated cable carries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
700573 7 x 25 + 6 x 4 x 1,0 41,0 1910,0 2140,0 4 702801 7 G 35 35,8 2746,0 3050,0 2
770009 7 x 35 + 6 x 4 x 1,0 42,5 2625,0 2950,0 2
700574 7 x 50 + 6 x 4 x 1,0 51,0 3590,0 4030,0 1

Dimensions and specifications may be changed without prior notice.

824
Renewable Energy and Transportation / Cables for Aircraft feeder lines

AIRPORT 400 Hz trailing, PUR, halogen-free, flame retardant

Technical data Cable structure Properties


Temperature range Part Nos. 700566-700569 Part Nos. 700570, 770001-770003
-40C to +90C Fine copper wire in acc. with Low adhesion, abrasion resistant,
Nominal voltage DIN VDE 0295 and IEC 60228 halogen-free, resistant to UV-, oil-,
115/200 V Special plastic core insulation hydrolysis and microbial attack
Operating voltage Sheath colour yellow (RAL 1021)
U0/U 0,6/1 kV Part Nos. 700570, 770001-770003 Note
Test voltage Fine copper wire in acc. with DIN VDE 0295 Distribution only over authorised partner
4000 V and IEC 60228
Minimum bending radius Core insulation PP/PUR, grey with number
6x cable 1-4/1 mm
Core 1 mm stranded with bundle
conductor
Double-sheath PUR/PUR
Sheath colour yellow (RAL 1021)
Part Nos. 700571, 770005, 770004,
700572
Each set of 4 parts, 700570,
770001-770003, is stranded

Application
400 Hz cables are used to supply power to aircraft (on-board power), data processing systems, radar stations, radio stations, etc. For safety reasons,
400 Hz cables are used to connect data processing systems, radar systems and communications systems to uninterruptible power supplies. Such
power supplies prevent a total failure of power and compensate for frequency and voltage fluctuations. Suitable for installation indoors, outdoors.
Highly flexible, and can thus be plugged directly into the connector in the aircraft without an adapter, and without endangering the contacts.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
700566 1 x 35 11,5 336,0 430,0 2 700571 4 x 1 x 35 + 4 x 1,0 33,0 1498,0 2600,0 2
700570 1 x 35 + 4 x 1,0 16,1 375,0 490,0 2 770005 4 x 1 x 50 + 4 x 1,0 40,0 2074,0 3900,0 1
700567 1 x 50 12,6 480,0 665,0 1 770004 4 x 1 x 70 + 4 x 1,0 49,2 2844,0 4300,0 2/0
770001 1 x 50 + 4 x 1,0 17,0 519,0 600,0 1 700572 4 x 1 x 120 + 4 x 1,0 56,0 4765,0 7400,0 4/0
700568 1 x 70 14,0 672,0 910,0 2/0
770002 1 x 70 + 4 x 1,0 20,5 711,0 800,0 2/0
700569 1 x 120 23,0 1152,0 1545,0 4/0
770003 1 x 120 + 4 x 1,0 25,0 1191,0 1400,0 4/0

Dimensions and specifications may be changed without prior notice.

825
CABLES FOR COMMERCIAL VEHICLES

Designation Properties Page

HELUTRUCK 270
with ADR approval, PVC, low-voltage cable for commercial vehicles 828

HELUTRUCK 271 with ADR approval, PUR, low-voltage cable for commercial vehicles 829

HELUTRUCK 272
with ADR approval, ribbon cable for side marker lights 830
HELUTRUCK 273 Battery cable, battery charging cable, twin cable 831

827
Renewable Energy and Transportation / Cables for Commercial Vehicles

HELUTRUCK 270 (FLRYY) with ADR-approval, PVC low voltage cable for
commercial vehicles

Technical data Cable structure Properties


Temperature range Bare copper-conductor, to Cold-resistant special PVC sheath,
-40C to +85C DIN VDE 0295 cl.5, fine-wire, UV-resistant
Test voltage IEC 60228 cl.5 Largely resistant to oil, weather, and
2000 V min. 5 minutes Core insulation of cold-resistant special PVC chemicals; Chemical resistance (see
Capacitance Core identification coloured, table Technical Information)
max. 50 pF/m for the data pair see table below Tests
max. 100 pF/m between data pair cores Outer sheath of special PVC PVC self-extinguishing and flame retardant
and the other cores also available with PUR sheath acc. to DIN VDE 0482-332-1-2,
Insulation resistance Sheath colour black DIN EN 60332-1-2, IEC 60332-1 (equivalent
min. 20 MOhm x km DIN VDE 0472 part 804 test method B)
Minimum bending radius These cables conform to the
12x cable national standard ISO 4141 and the
international standard DIN/ISO 6722
Component codes T.EGG.073-03
Special feature:
Complies with GGVS regulations
Approved and tested by the TV
Complies with ADR regulations

Note
Further sizes are available on request.

Application
These low-voltage cables are designed for the wiring of electrical installations in the manufacture of commercial vehicles. Due to the ADR-approval
especially suitable for trailers and semitrailers manufactured for the transport of GGVS hazardous substances.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
700016 2 x 0,5 4,8 9,6 40,0 20 700579 4 x 1,5 7,5 57,6 106,0 16
700575 2 x 0,75 + 2 x 1,5 7,0 43,2 91,0 18 700407 8 x 1,5 + 1 x 2,5 11,5 139,2 238,0 16
702179 3 x 0,75 5,3 21,6 52,4 17 75262 6 x 1,5 + 1 x 2,5 10,3 110,5 187,0 16
700582 7 x 0,75 7,3 50,4 101,0 18 700032 7 x 1,5 10,3 100,8 185,0 16
75255 2x1 6,0 19,2 56,0 17 75261 7 x 1,5 8,9 100,2 165,0 16
75254 2x1 6,0 19,2 56,0 17 75263 8 x 1,5 + 1 x 2,5 11,7 139,2 238,0 16
75256 3x1 6,3 28,8 66,0 17 700583 8 x 1,5 + 5 x 2,5 14,8 235,2 360,0 16
700578 3 x 1 6,6 28,8 66,0 17 75267 9 x 1,5 + 4 x 2,5 14,8 200,0 350,0 16
75257 4x1 6,8 38,4 80,0 17 75265 10 x 1,5 + 3 x 2,5 12,5 168,0 366,0 16
75258 5x1 7,5 48,0 98,0 17 75319 10 x 1,5 + 3 x 2,5 + 2 x 1,5 14,4 244,8 393,0 16
75260 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 700017 10 x 1,5 + 3 x 2,5 + 2 x 1,5 14,3 244,8 391,0 16
700580 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 705167 10 x 1,5 + 3 x 2,5 + 2 x 1,5 14,4 244,8 393,0 16
75259 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 75266 10 x 1,5 + 3 x 2,5 13,0 216,0 345,0 16
700581 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 700018 11 x 1,5 + 3 x 2,5 13,5 230,4 365,0 16
700849 5 x 1 + 1 x 2,5 9,3 65,7 149,5 16 700142 3 x 2,5 + 4 x 1,5 10,3 129,6 221,0 14
700576 2 x 1,5 6,6 28,8 66,0 16 706627 4 x 6 + 1 x 1,5 13,7 244,8 411,0 18
700577 2 x 1,5 6,6 28,8 66,0 16

Dimensions and specifications may be changed without prior notice.

828
Renewable Energy and Transportation / Cables for Commercial Vehicles

HELUTRUCK 271 (FLRYY11Y) with ADR-approval, PUR low voltage


cable for commercial vehicles

Technical data Cable structure Properties


Temperature range Bare copper-conductor, to PUR outer sheath, low adhesion, abrasion
-40C to +85C DIN VDE 0295 cl.5, fine-wire, resistant, halogen-free, resistant to UV-,
Test voltage IEC 60228 cl.5 oil-, hydrolysis and microbial attack
2000 V min. 5 minutes Core insulation of cold-resistant special PVC Largely resistant to oil, weather, and
Capacitance Core identification chemicals; Chemical resistance (see
max. 50 pF/m for the data pair see table below table Technical Information)
max. 100 pF/m between data pair Inner sheath of special PVC Tests
cores and the other cores Outer sheath of PUR These cables conform to the
Insulation resistance also available with PVC sheath national standard ISO 4141 and the
min. 20 MOhm x km Sheath colour black international standard DIN/ISO 6722
Minimum bending radius Component codes T.EGG.074-03
12x cable Special feature:
Complies with GGVS regulations
Approved and tested by the TV
PUR sheath provides high resistance to
abrasion, UV and wear
Complies with ADR regulations

Note
Further sizes are available on request.

Application
These low-voltage cables are designed for the wiring of electrical installations in the manufacture of commercial vehicles. Due to the ADR-approval
especially suitable for trailers and semitrailers manufactured for the transport of GGVS hazardous substances.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
708090 9 x 0,5 + 4 x 2,5 + 2 x 0,5 12,0 148,0 490,0 16 700587 2 x 1,5 6,6 28,8 67,0 16
709556 2 x 0,75 5,4 14,4 45,8 18 700589 4 x 1,5 7,5 57,6 105,0 16
700585 2 x 0,75 + 2 x 1,5 7,0 43,2 91,0 18 75536 6 x 1,5 + 1 x 2,5 10,3 110,4 187,0 16
700592 7 x 0,75 7,9 50,4 100,0 18 75535 7 x 1,5 8,9 100,8 165,0 16
75528 2x1 6,0 19,0 56,0 17 75537 8 x 1,5 + 1 x 2,5 11,7 139,2 238,0 16
75529 2x1 6,0 19,0 56,0 17 75539 10 x 1,5 + 3 x 2,5 14,4 214,0 366,0 16
75530 3x1 6,3 28,8 66,0 17 700594 10 x 1,5 + 3 x 2,5 14,4 214,0 366,0 16
700588 3 x 1 6,3 28,8 66,0 17 75538 10 x 1,5 + 3 x 2,5 + 2 x 1,5 14,4 244,8 393,0 16
75531 4x1 6,8 38,5 80,0 17 700595 18 x 1,5 17,0 259,2 520,0 16
75532 5x1 7,5 48,1 98,0 17 700596 25 x 1,5 19,9 360,0 730,0 16
700591 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 701045 2 x 2,5 7,6 48,0 104,9 16
75533 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 701044 2 x 2,5 + 5 x 1,5 10,3 120,0 214,4 16
700590 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 75932 2 x 4 + 3 x 1,5 + 2 x 1,5 12,0 148,8 230,0 12
75534 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 75541 2 x 6 + 3 x 1,5 + 2 x 1,5 12,0 187,2 320,0 10
705135 7 x 1 8,6 68,0 133,1 17 75540 2 x 6 + 3 x 1,5 12,0 158,6 270,0 10
700586 2 x 1,5 6,6 28,8 67,0 16

Dimensions and specifications may be changed without prior notice.

829
Renewable Energy and Transportation / Cables for Commercial Vehicles

HELUTRUCK 272 (FLRYYF) with ADR-approval, flat cable for the sideways
lighting

Technical data Cable structure Properties


Flat cable for the sideways Bare copper-conductor, to Cold resistant, UV-resistant, largely
lighting (FLRYYF) DIN VDE 0295 cl.5, fine-wire, resistant to oil, weather, and chemicals,
Temperature range IEC 60228 cl.5 Chemical resistance see table
-40C to +85C Core insulation of cold resistant special PVC TechnicalInformation
Test voltage Core identification Polarity easy to determine by a
2000 V Art.-Nr. 76706 BK, WH white line on the sheath above the
Insulation resistance Art.-Nr. 78983 WH, BN white core
min. 20 MOhm x km Art.-Nr. 700035 BK, WH Tests
Minimum bending radius Outer sheath of cold-resistant special PVC PVC self-extinguishing and flame retardant
fixed installation 5x cable also available with PUR sheath acc. to DIN VDE 0482-332-1-2,
Sheath colour black DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Special feature
Complies with GGVS regulations
Approved and tested by the TV
Complies with ADR regulations

Note
Further sizes are available on request.

Application
This low-voltage cable is designed for the wiring of electrical installations in the manufacture of commercial vehicles. Especially suitable for trailers
and semitrailers. This flat cable can be used for simple and quick contacting of sidelights by means of core penetration. Its flat construction and the
special contacting method eliminate the need for time-consuming assembly of cables. This facilitates quick installation, making it possible to save a
great deal of time. ADR approval for transport of hazardous substances by trailers and semitrailers.
HELUTRUCK 272
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight app.
mm app. mm kg / km kg / km
76706 2 x 1,5 4,5 x 6,8 28,8 90,0 16
700035 2 x 1,5 4,5 x 6,8 28,8 90,0 16
78983 2 x 1,5 4,5 x 6,8 28,8 90,0 16

Dimensions and specifications may be changed without prior notice.

830
Renewable Energy and Transportation / Cables for Commercial Vehicles

HELUTRUCK 273 battery cable, battery charging cable, twin cable

Technical data Cable structure Properties


Battery cable, battery charging cable Bare copper-conductor, to Cold restistant, UV-resistant, largely
(twin cable) DIN VDE 0295 cl.5, fine-wire, resistant to oil, weather, and chemicals,
Temperature range IEC 60228 cl.5 Chemical resistance see table
-40C to +85C Core insulation of cold-resistant special PVC Technical Information
Nominal voltage Core identification RD, BK The additional sheath means that the cable
75 V DC Outer sheath of cold-resistant special PVC is very robust, and can be installed without
Test voltage also available with PUR sheath a corrugated conduit
3000 V Sheath colour transparent Installation time is shorter due to twin
Insulation resistance design
min. 20 MOhm x km The special construction of the conductor
Minimum bending radius enables optimal crimping
fixed installation 15x cable Easy mechanical separation of the sheath
web
Tests
PVC self-extinguishing and flame retardant
acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)

Note
Further sizes are available on request.

Application
This battery cable can be used between the battery and the ultimate consumer (e.g. DC motor of the tail-lift).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
HELUTRUCK 273
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight app. kg / km
mm app. mm kg / km
75507 2 x 2,5 5,6 x 28,8 48,0 87,0 14
75508 2x4 6,6 x 14,8 77,0 125,0 12
75509 2x6 6,8 x 14,6 116,0 175,0 10
75510 2 x 10 8,1 x 17,2 192,0 270,0 8
75511 2 x 16 8,9 x 18,5 308,0 390,0 6
75512 2 x 25 10,7 x 21,7 480,0 575,0 4
75513 2 x 35 12,8 x 26,6 672,0 820,0 2
75514 2 x 50 14,1 x 29,2 960,0 1065,0 1
709043 2 x 70 16,1 x 33,2 1344,0 1475,0 2/0

Dimensions and specifications may be changed without prior notice.

831
CABLES FOR TRAIN & TRAFFIC

Designation Properties Approvals Page

HELUTRAIN 3GKW
train cable, robust special core cable, halogen-free 0.6/1 kV 834

HELUTRAIN 4GKW-AXplus single-core train cable, robust halogen-free, 1.8/3kV meter marking 835

Vehicle cable FLY one colour / two color /old type FLK), in accordance with DIN ISO 6722 836

Vehicle cable FLY one colour / two color /old type FLK), in accordance with DIN ISO 6722 837

Vehicle cable FLY one colour / two color /old type FLK), in accordance with DIN ISO 6722 838

Vehicle cable FLRY FLRY-type A (FLK-R)/ -type B (FLK-D) 839

833
Renewable Energy and Transportation / Cables for Trains

HELUTRAIN 3GKW Train-Cable, robust special single core, halogen-free,


0,6/1kV

Technical data Cable structure Properties


Temperature resistant special-insulated Tinned copper, fine wire conductors, The materials used in manufacture are
wire conform to DIN VDE 0295 cl.5 and cadmium-free and contain no silicone
Temperature range IEC 60228 cl.5 and free from substances harmful to
flexing -35C to +90C Core insulation from Polyolefin the wetting properties of lacquers
fixed installation -45C to +120C Copyolymer, cross-linked Resistant to mechanical influences in rough
Short-circuit temperature Colour grey or green-yellow environmental conditions
+250C Good chemical durability with simultaneous
Nominal voltage high fire safety
U0/U 0,6/1 kV (AC) Reduction of toxic combustion gases and
U0/U 0,9/1,8 kV (DC) the spread of the fire source in case of fire
Test voltage increases protection against personal injury
3,5 kV and property damage
Minimum bending radius Tests
fixed installation for outer Flame test acc. to
up to 10 mm 3x outer DIN VDE 0482-332-3, BS 4066 part 3,
> 10 mm 4x outer DIN EN 60332-3, IEC 60332-3 (previously
flexing for outer DIN VDE 0472 part 804 test method C)
up to 10 mm 5x outer Flame retardant acc. to
> 10 mm 6x outer DIN VDE 0482-331-1-2, DIN EN 60332-1-2,
IEC 60332-1
Corrosiveness of combustion gases
acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-2, IEC 60754-2
(equivalent DIN VDE 0472 part 813)
Halogen-free acc. to DIN VDE 0482
part 267, DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(equivalent DIN VDE 0472 part 816)
Oil- and gasoline resistant to
EN 50305
Ozon resistant to EN 50305
Low fire load (DIN 51900)
No fluor (EN 60684-2)

Application
HELUTRAIN 3 GKW train cable are Halogen-free and suitable for fixed and protected installation in rough environmental conditions inside and outside
of rail vehicles. For connecting fixed and moving parts. Due to the flexibility and the small outer diameter suitable for fixed installation in small bending
radii.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC..
Core colour grey Core colour green-yellow
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
59114 1 x 0,5 2,0 4,8 9,0 - 53762 1 x 0,5 2,0 4,8 9,0 -
59115 1 x 0,75 2,2 7,2 12,0 - 53763 1 x 0,75 2,2 7,2 12,0 -
59116 1x1 2,4 9,6 14,0 - 53764 1x1 2,4 9,6 14,0 -
59117 1 x 1,5 2,7 14,4 21,0 - 53765 1 x 1,5 2,7 14,4 21,0 -
59118 1 x 2,5 3,4 24,0 31,0 - 53766 1 x 2,5 3,4 24,0 31,0 -
59119 1x4 3,9 38,4 46,0 - 53767 1x4 3,9 38,4 46,0 -
59126 1x6 4,6 57,6 68,0 - 53768 1x6 4,6 57,6 68,0 -
59127 1 x 10 5,5 96,0 111,0 - 53769 1 x 10 5,5 96,0 111,0 -
59128 1 x 16 7,1 154,0 166,0 - 53770 1 x 16 7,1 154,0 166,0 -
59129 1 x 25 8,6 240,0 250,0 - 53771 1 x 25 8,6 240,0 250,0 -
59130 1 x 35 9,8 336,0 350,0 - 53772 1 x 35 9,8 336,0 350,0 -
59131 1 x 50 12,0 480,0 500,0 - 53773 1 x 50 12,0 480,0 500,0 -
59132 1 x 70 14,2 672,0 690,0 - 53774 1 x 70 14,2 672,0 690,0 -
59133 1 x 95 15,6 912,0 940,0 - 53775 1 x 95 15,6 912,0 940,0 -
59134 1 x 120 17,6 1152,0 1180,0 - 53776 1 x 120 17,6 1152,0 1180,0 -
59135 1 x 150 20,3 1440,0 1460,0 - 53777 1 x 150 20,3 1440,0 1460,0 -

Dimensions and specifications may be changed without prior notice. (RK01)

834
Renewable Energy and Transportation / Cables for Trains

HELUTRAIN 4GKW-AXplus Train-Cable, robust special single core,


halogen-free, 1,8/3kV, meter marking

Technical data Cable structure Properties


Temperature range Tinned copper conductor, fine wire The materials used in manufacture are
fixed installation: -60C to +120C stranded acc. to DIN VDE 0295 cl.5, cadmium-free and contain no silicone
flexing: -35C to +90C BS 6360 cl.5 or IEC 60228 cl.5 and free from substances harmful to
short circuit: +200C Core insulation of cross-linked the wetting properties of lacquers
Nominal voltage polyolefin copolymer Tests
U0/U 1,8/3 kV (AC) Outer sheath of cross-linked Elastomer Flame test acc. to
U0/U 2,7/5,4 kV (DC) Sheath colour black DIN VDE 0482-332-3, BS 4066 part 3,
Test voltage DIN EN 60332-3, IEC 60332-3 (previously
6,5 kV AC DIN VDE 0472 part 804 test method C)
Minimum bending radius Flame retardant acc. to
fixed installation for outer DIN VDE 0482-331-1-2, DIN EN 60332-1-2,
up to 10 mm 5x outer IEC 60332-1
> 10 mm 6x outer Corrosiveness of combustion gases
flexing for outer acc. to DIN VDE 0482 part 267,
up to 10 mm 7x outer DIN EN 50267-2-2, IEC 60754-2
> 10 mm 8x outer (equivalent DIN VDE 0472 part 813)
Halogen-free acc. to DIN VDE 0482
part 267, DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(equivalent DIN VDE 0472 part 816)
No toxic gases (EN 50305)
Oil- and gasoline resistant to
EN 50305
Ozon resistant to EN 50305
Low fire load (DIN 51900)
No fluor (EN 60684-2)
High voltage resistance and mechanical
influences in rough environmental
conditions
Resistant to mechanical influences in rough
environmental conditions
Good chemical durability with simultaneous
high fire safety
Reduction of toxic combustion gases and
the spread of the fire source in case of fire
increases protection against personal injury
and property damage

Note
screened analogue type
part no. 54092
HELUTRAIN-C 4GKW 1x35

Application
For fixed installation inside and outside of unprotected rail cars and buses. For connecting fixed and moving parts.
Suitable for wiring of switchboards, distribution boards, power converters, electrical panels and blocks, resistor and brake blocks. T
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
59262 1 x 1,5 3,6 14,4 24,0 - 59312 1 x 50 13,6 480,0 536,0 -
59263 1 x 2,5 4,0 24,0 34,0 - 59313 1 x 70 16,0 672,0 729,0 -
59264 1x4 4,9 38,4 53,0 - 59314 1 x 95 17,5 912,0 960,0 -
59265 1x6 5,5 57,6 74,0 - 59315 1 x 120 20,0 1152,0 1203,0 -
59266 1 x 10 6,5 96,0 118,0 - 59316 1 x 150 22,0 1440,0 1464,0 -
59267 1 x 16 8,7 153,6 182,0 - 59317 1 x 185 24,1 1776,0 1802,0 -
59268 1 x 25 10,2 240,0 274,0 - 59318 1 x 240 26,8 2304,0 2348,0 -
59269 1 x 35 11,5 336,0 379,0 -

Dimensions and specifications may be changed without prior notice. (RK01)

835
Renewable Energy and Transportation / Cables for Commercial Vehicles

Vehicle Cable FLY one colour / two colour (old type FLK), according to DIN ISO 6722

Technical data Cable structure Properties


Special PVC core insulation Bare copper conductor, soft annealed Oil and fuel resistant as per
Temperature stability electrolytic copper E-Cu58 F21 according DIN ISO 6722 part 2
(3000 h) -25C to +90C to DIN 40500 part 4 (the mechanical
Nominal voltage requirements valid for unprocessing single Note
up to 24 V wires) Minimum quantities
Test voltage Copper conductor fine wire stranded as Per cross-section and colour combination:
1 kV (effective value) per DIN ISO 6722 part 3 2-colour
Breakdown voltage PVC core insulation 0,5 to 2,5 mm = 3 km
5 kV (effective value) For three-colour combinations we produce 4,0 to 25 mm = 1 km
Specific volume resistance only on request 3-colour
min. 109 Ohm x mm 0,5 to 2,5 mm = 5 km
4,0 to 25 mm = 3 km
Remaining cross-sections on request.

Application
PVC insulated single core cables are used for vehicle constructions.
one colour
Cross- Outer Cop. Weight BK BU BN RD WH GY VT YE PK GN OG
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 29800 40217 40243 40282 40204 40321 40269 40308 40295 40256 40230
0,5 2,0 - 2,3 4,8 9,0 - - - - - - - - - - -
Part no. 29801 40218 40244 40283 40205 40322 40270 40309 40296 40257 40231
0,75 2,2 - 2,5 7,2 12,0 - - - - - - - - - - -
Part no. 29802 40219 40245 40284 40206 40323 40271 40310 40297 40258 40232
1 2,4 - 2,7 9,6 15,0 - - - - - - - - - - -
Part no. 29803 40220 40246 40285 40207 40324 40272 40311 40298 40259 40233
1,5 2,7 - 3,0 14,4 20,0 - - - - - - - - - - -
Part no. 29804 40221 40247 40286 40208 40325 40273 40312 40299 40260 40234
2,5 3,3 - 3,6 24,0 32,0 - - - - - - - - - - -
Part no. 29805 40222 40248 40287 40209 40326 40274 40313 40300 40261 40235
4 4,0 - 4,4 38,4 48,0 - - - - - - - - - - -
Part no. 29806 40223 40249 40288 40210 40327 40275 40314 40301 40262 40236
6 4,6 - 5,0 57,6 68,0 - - - - - - - - - - -
Part no. 29807 40224 40250 40289 40211 40328 40276 40315 40302 40263 40237
10 6,0 - 6,5 96,0 117,0 - - - - - - - - - - -
Part no. 29808 40225 40251 40290 40212 40329 40277 40316 40303 40264 40238
16 7,0 - 8,3 154,0 189,0 - - - - - - - - - - -
Part no. 29809 40226 40252 40291 40213 40330 40278 40317 40304 40265 40239
25 9,4 - 10,4 240,0 288,0 - - - - - - - - - - -
Part no. 29810 40227 40253 40292 40214 40331 40279 40318 40305 40266 40240
35 10,8 - 11,6 336,0 382,0 - - - - - - - - - - -
Part no. 29811 40228 40254 40293 40215 40332 40280 40319 40306 40267 40241
50 12,5 - 13,5 480,0 540,0 - - - - - - - - - - -
Part no. 29812 40229 40255 40294 40216 40333 40281 40320 40307 40268 40242
70 14,5 - 15,5 672,0 744,0 - - - - - - - - - - -

Dimensions and specifications may be changed without prior notice. (RK01)

836
Renewable Energy and Transportation / Cables for Commercial Vehicles

Vehicle Cable FLY one colour / two colour (old type FLK), according to DIN ISO 6722
two colour
Cross- Outer Cop. Weight WH/GY WH/RD WH/BN WH/BU WH/BK YE/GY YE/RD YE/BN YE/BU YE/BK
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 40334 40347 40360 40373 40386 40399 40412 40425 40438 40451
0,5 2,0 - 2,3 4,8 9,0 - - - - - - - - - -
Part no. 40335 40348 40361 40374 40387 40400 40413 40426 40439 40452
0,75 2,2 - 2,5 7,2 12,0 - - - - - - - - - -
Part no. 40336 40349 40362 40375 40388 40401 40414 40427 40440 40453
1 2,4 - 2,7 9,6 15,0 - - - - - - - - - -
Part no. 40337 40350 40363 40376 40389 40402 40415 40428 40441 40454
1,5 2,7 - 3,0 14,4 20,0 - - - - - - - - - -
Part no. 40338 40351 40364 40377 40390 40403 40416 40429 40442 40455
2,5 3,3 - 3,6 24,0 32,0 - - - - - - - - - -
Part no. 40339 40352 40365 40378 40391 40404 40417 40430 40443 40456
4 4,0 - 4,4 38,4 48,0 - - - - - - - - - -
Part no. 40340 40353 40366 40379 40392 40405 40418 40431 40444 40457
6 4,6 - 5,0 57,6 68,0 - - - - - - - - - -
Part no. 40341 40354 40367 40380 40393 40406 40419 40432 40445 40458
10 6,0 - 6,5 96,0 117,0 - - - - - - - - - -
Part no. 40342 40355 40368 40381 40394 40407 40420 40433 40446 40459
16 7,0 - 8,3 154,0 189,0 - - - - - - - - - -
Part no. 40343 40356 40369 40382 40395 40408 40421 40434 40447 40460
25 9,4 - 10,4 240,0 288,0 - - - - - - - - - -
Part no. 40344 40357 40370 40383 40396 40409 40422 40435 40448 40461
35 10,8 - 11,6 336,0 382,0 - - - - - - - - - -
Part no. 40345 40358 40371 40384 40397 40410 40423 40436 40449 40462
50 12,5 - 13,5 480,0 540,0 - - - - - - - - - -
Part no. 40346 40359 40372 40385 40398 40411 40424 40437 40450 40463
70 14,5 - 15,5 672,0 744,0 - - - - - - - - - -

two colour
Cross- Outer Cop. Weight GY/GN GY/RD GY/BN GY/BK GN/WH GN/GY GN/BN GN/BU GN/BK
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 40464 40477 40490 40802 40503 40516 40529 40542 40555
0,5 2,0 - 2,3 4,8 9,0 - - - - - - - - -
Part no. 40465 40478 40491 40803 40504 40517 40530 40543 40556
0,75 2,2 - 2,5 7,2 12,0 - - - - - - - - -
Part no. 40466 40479 40492 40804 40505 40518 40531 40544 40557
1 2,4 - 2,7 9,6 15,0 - - - - - - - - -
Part no. 40467 40480 40493 40805 40506 40519 40532 40545 40558
1,5 2,7 - 3,0 14,4 20,0 - - - - - - - - -
Part no. 40468 40481 40494 40806 40507 40520 40533 40546 40559
2,5 3,3 - 3,6 24,0 32,0 - - - - - - - - -
Part no. 40469 40482 40495 40807 40508 40521 40534 40547 40560
4 4,0 - 4,4 38,4 48,0 - - - - - - - - -
Part no. 40470 40483 40496 40808 40509 40522 40535 40548 40561
6 4,6 - 5,0 57,6 68,0 - - - - - - - - -
Part no. 40471 40484 40497 40809 40510 40523 40536 40549 40562
10 6,0 - 6,5 96,0 117,0 - - - - - - - - -
Part no. 40472 40485 40498 40810 40511 40524 40537 40550 40563
16 7,0 - 8,3 154,0 189,0 - - - - - - - - -
Part no. 40473 40486 40499 40811 40512 40525 40538 40551 40564
25 9,4 - 10,4 240,0 288,0 - - - - - - - - -
Part no. 40474 40487 40500 40812 40513 40526 40539 40552 40565
35 10,8 - 11,6 336,0 382,0 - - - - - - - - -
Part no. 40475 40488 40501 40813 40514 40527 40540 40553 40566
50 12,5 - 13,5 480,0 540,0 - - - - - - - - -
Part no. 40476 40489 40502 40814 40515 40528 40541 40554 40567
70 14,5 - 15,5 672,0 744,0 - - - - - - - - -

Dimensions and specifications may be changed without prior notice.

837
Renewable Energy and Transportation / Cables for Commercial Vehicles

Vehicle Cable FLY one colour / two colour (old type FLK), according to DIN ISO 6722
two colour
Cross- Outer Cop. Weight RD/WH RD/YE RD/GY RD/GN RD/BU RD/BK BN/WH BN/YE BN/GN BN/BK
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 40568 40581 40594 40607 40620 40633 40646 40659 40672 40685
0,5 2,0 - 2,3 4,8 9,0 - - - - - - - - - -
Part no. 40569 40582 40595 40608 40621 40634 40647 40660 40673 40686
0,75 2,2 - 2,5 7,2 12,0 - - - - - - - - - -
Part no. 40570 40583 40596 40609 40622 40635 40648 40661 40674 40687
1 2,4 - 2,7 9,6 15,0 - - - - - - - - - -
Part no. 40571 40584 40597 40610 40623 40636 40649 40662 40675 40688
1,5 2,7 - 3,0 14,4 20,0 - - - - - - - - - -
Part no. 40572 40585 40598 40611 40624 40637 40650 40663 40676 40689
2,5 3,3 - 3,6 24,0 32,0 - - - - - - - - - -
Part no. 40573 40586 40599 40612 40625 40638 40651 40664 40677 40690
4 4,0 - 4,4 38,4 48,0 - - - - - - - - - -
Part no. 40574 40587 40600 40613 40626 40639 40652 40665 40678 40691
6 4,6 - 5,0 57,6 68,0 - - - - - - - - - -
Part no. 40575 40588 40601 40614 40627 40640 40653 40666 40679 40692
10 6,0 - 6,5 96,0 117,0 - - - - - - - - - -
Part no. 40576 40589 40602 40615 40628 40641 40654 40667 40680 40693
16 7,0 - 8,3 154,0 189,0 - - - - - - - - - -
Part no. 40577 40590 40603 40616 40629 40642 40655 40668 40681 40694
25 9,4 - 10,4 240,0 288,0 - - - - - - - - - -
Part no. 40578 40591 40604 40617 40630 40643 40656 40669 40682 40695
35 10,8 - 11,6 336,0 382,0 - - - - - - - - - -
Part no. 40579 40592 40605 40618 40631 40644 40657 40670 40683 40696
50 12,5 - 13,5 480,0 540,0 - - - - - - - - - -
Part no. 40580 40593 40606 40619 40632 40645 40658 40671 40684 40697
70 14,5 - 15,5 672,0 744,0 - - - - - - - - - -

two colour
Cross- Outer Cop. Weight BU/WH BU/YE BU/GN BU/RD BK/WH BK/YE BK/GN BK/RD
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 40698 40711 40724 40737 40750 40763 40776 40789
0,5 2,0 - 2,3 4,8 9,0 - - - - - - - -
Part no. 40699 40712 40725 40738 40751 40764 40777 40790
0,75 2,2 - 2,5 7,2 12,0 - - - - - - - -
Part no. 40700 40713 40726 40739 40752 40765 40778 40791
1 2,4 - 2,7 9,6 15,0 - - - - - - - -
Part no. 40701 40714 40727 40740 40753 40766 40779 40792
1,5 2,7 - 3,0 14,4 20,0 - - - - - - - -
Part no. 40702 40715 40728 40741 40754 40767 40780 40793
2,5 3,3 - 3,6 24,0 32,0 - - - - - - - -
Part no. 40703 40716 40729 40742 40755 40768 40781 40794
4 4,0 - 4,4 38,4 48,0 - - - - - - - -
Part no. 40704 40717 40730 40743 40756 40769 40782 40795
6 4,6 - 5,0 57,6 68,0 - - - - - - - -
Part no. 40705 40718 40731 40744 40757 40770 40783 40796
10 6,0 - 6,5 96,0 117,0 - - - - - - - -
Part no. 40706 40719 40732 40745 40758 40771 40784 40797
16 7,0 - 8,3 154,0 189,0 - - - - - - - -
Part no. 40707 40720 40733 40746 40759 40772 40785 40798
25 9,4 - 10,4 240,0 288,0 - - - - - - - -
Part no. 40708 40721 40734 40747 40760 40773 40786 40799
35 10,8 - 11,6 336,0 382,0 - - - - - - - -
Part no. 40709 40722 40735 40748 40761 40774 40787 40800
50 12,5 - 13,5 480,0 540,0 - - - - - - - -
Part no. 40710 40723 40736 40749 40762 40775 40788 40801
70 14,5 - 15,5 672,0 744,0 - - - - - - - -

Dimensions and specifications may be changed without prior notice.

838
Renewable Energy and Transportation / Cables for Commercial Vehicles

Vehicle Cable FLRY FLRY-Type A (FLK-R) / -Type B (FLK-D)

Technical data Cable structure Properties


Special PVC core insulation Bare copper conductor, soft annealed Oil and fuel resistant as per
Temperature stability electrolytic copper E-Cu58 F21 according DIN ISO 6722 part 2
(3000 h) -40C to +105C to DIN 40500 part 4 (the mechanical Special characteristics
Nominal voltage up to 24 V requirements valid for unprocessing single Place and weight saving by using the
Test voltage wires) reduced insulation wall thickness.
1 kV (effective value) Stranded copper conductor bare, Requirements and tests
Breakdown voltage conductor make-up as per DIN 72551 As per DIN 72551 part 5
5 kV (effective value) Type A: Conductor make-up symmetrical
Specific volume resistance Type B: Conductor make-up Note
min. 109 Ohm mm unsymmetrical Indication for order
Type A = Conductor make-up symmetrical Core insualtion of special PVC Please mention the core colour and colour
(1+6+12), number of single wires are odd combination clearly to your order,
number; a single wire laying at the centre because a re-acceptance of false ordered
of the cross-section. articles is impossible.
Minimum quantities
Per cross-section and colour combination:
2-colour
0,5 to 2,5 mm = 3 km
4,0 to 25 mm = 1 km
3-colour
0,5 to 2,5 mm = 5 km
4,0 to 25 mm = 3 km
Remaining cross-sections on request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
PVC insulated single core cables are used for vehicle constructions.
FLRY - Type A (FLK-R)
Cross- Outer Cop. Weight BK BU BN RD WH GY VT YE PK GN OG
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 28484 28486 28488 28491 28485 28494 28490 28493 28492 28489 28487
0,35 1,2 - 1,3 3,4 4,5 - - - - - - - - - - -
Part no. 28495 28497 28499 28502 28496 28505 28501 28504 28503 28500 28498
0,5 1,4 - 1,6 4,8 6,6 - - - - - - - - - - -

FLRY - Type B (FLK-D)


Cross- Outer Cop. Weight BK BU BN RD WH GY VT YE PK GN OG
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 28506 28508 28510 28513 28507 28516 28512 28515 28514 28511 28509
0,75 1,7 - 1,9 7,2 9,0 - - - - - - - - - - -
Part no. 28517 28519 28521 28524 28518 28527 28523 28526 28525 28522 28520
1 1,9 - 2,1 9,6 11,0 - - - - - - - - - - -
Part no. 28528 28530 28532 28535 28529 28538 28534 28537 28536 28533 28531
1,5 2,2 - 2,4 14,4 16,0 - - - - - - - - - - -
Part no. 28539 28541 28543 28546 28540 28549 28545 28548 28547 28544 28542
2,5 2,7 - 3,0 24,0 26,0 - - - - - - - - - - -
Part no. 28550 28552 28554 28557 28551 28560 28556 28559 28558 28555 28553
4 3,4 - 3,7 38,0 42,0 - - - - - - - - - - -
Part no. 28561 28563 28565 28568 28562 28571 28567 28570 28569 28566 28564
6 4,0 - 4,3 58,0 61,0 - - - 5/0 - - - - - - -

Dimensions and specifications may be changed without prior notice. (RK01)

839
PRE-ASSEMBLED CABLES

Servo motor, feedback & fan cables 842

ROBOFLEX-recycle 878

Connecting cables & extensions 898

841
842
SERVO MOTOR, FEEDBACK & FAN CABLES

Designation Properties Approvals Page

Base line for use on SIEMENS drive systems

Pre-assembled servo motor cables for fixed laying 844

Pre-assembled servo motor cables for mobile use 845

Pre-assembled feedback cables for fixed laying 846

Pre-assembled feedback cables for mobile use 847

Pre-assembled servo motor cables for fixed laying 848

Pre-assembled servo motor cables for mobile use 849

Pre-assembled feedback cables for fixed laying 850

Pre-assembled feedback cables for mobile use 851

Base line for use on REXROTH drive systems

Pre-assembled servo motor cables for mobile use (PVC) 852

Pre-assembled servo motor cables for mobile use (PUR) 853

Pre-assembled feedback cables for mobile use (PVC) 855

Pre-assembled feedback cables for mobile use (PUR) 856

Base line for use on LENZE drive systems

Pre-assembled servo motor cables for fixed laying 857

Pre-assembled servo motor cables for mobile use 858

Pre-assembled feedback cables for fixed laying 859

Pre-assembled feedback cables for mobile use 860

Pre-assembled fan cables for fixed laying 861

Pre-assembled fan cables for mobile use 862

Pre-assembled servo motor cables for fixed laying 863


Pre-assembled servo motor cables for mobile use 864
Pre-assembled feedback cables for fixed laying 865

Pre-assembled feedback cables for mobile use 866

Pre-assembled fan cables for fixed laying 867

Pre-assembled fan cables for mobile use 868

Base line for use on SEW drive systems

Pre-assembled servo motor cables for fixed laying 869

Pre-assembled servo motor cables for mobile use 870


Pre-assembled feedback cables for fixed laying 871
Pre-assembled feedback cables for mobile use 872

Pre-assembled servo motor cables for fixed laying 873

Pre-assembled servo motor cables for mobile use 874

For use on HEIDENHAIN measurement systems/hand wheels

Pre-assembled feedback cables 875

Pre-assembled adapter cable 876 U

843
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for fixed laying
Base line for use on SIEMENS drive systems

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled motor
flexing 0C to +60C Bare copper, acc. to IEC 60228 cl.6 connection cable is specially manufactured
fixed installation -20C to +80C PVC core insulation for applications with static installation.
Minimum bending radius Core identification U/L1/C/L+ The special PVC outer sheath
flexing 20x cable V/L2 allows use in many industrial
fixed installation 5x cable W/L3/D/L- environments of general machine
Max. acceleration GN-YE conductor and plant construction.
2 m/s Signal cores
Bending cycles Copper conductors, bare Characteristic
100,000 for 20x cable TPE-E core insulation Economical alternatives to the cable
Nominal voltage (UL/CSA) Core identification black, white carrier compatible cable types which
(power + signal) 1000 V Cores twisted in pairs otherwise meet all requirements of
Nominal voltage (VDE) Shield tin-plated copper braiding the servo drive manufacturers.
(power) U0/U 0,6/1 kV Complete shield of tin-plated copper These pre-assembled cables can be
(signal) 24 V braiding, coverage approx. 80% produced in any lengths and also with
Test voltage PVC outer sheath customer-specific modifications.
power cores 4 kV Sheath colour orange (RAL 2003)
signal cores 2 kV Note
Insulation resistance 20 MOhm x km
Please observe the drive or controller
manufacturer's information about
Approbations maximum permitted cable length.
DESINA (ISO 23570) The prefabricated cables listed here are not
VDE original parts, but accessories manufactured
UL/CSA by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
6FX5002-5CA01 5CA01 DESINA PVC 660224 6FX5002-5DA21 5DA21 DESINA PVC 660247
6FX5002-5CA11 5CA11 DESINA PVC 660227 6FX5002-5DA31 5DA31 DESINA PVC 660250
6FX5002-5CA21 5CA21 DESINA PVC 660230 6FX5002-5DA41 5DA41 DESINA PVC 660254
6FX5002-5CA31 5CA31 DESINA PVC 660234 6FX5002-5DA51 5DA51 DESINA PVC 660257
6FX5002-5CA41 5CA41 DESINA PVC 660237 6FX5002-5DA61 5DA61 DESINA PVC 660259
6FX5002-5CA51 5CA51 DESINA PVC 660238 6FX5002-5DA13 5DA13 DESINA PVC 660666
6FX5002-5CA61 5CA61 DESINA PVC 660239 6FX5002-5DA23 5DA23 DESINA PVC 660249
6FX5002-5CA13 5CA13 DESINA PVC 660229 6FX5002-5DA33 5DA33 DESINA PVC 660252
6FX5002-5CA23 5CA23 DESINA PVC 660232 6FX5002-5DA43 5DA43 DESINA PVC 660255
6FX5002-5DA01 5DA01 DESINA PVC 660241 6FX5002-5DA53 5DA53 DESINA PVC 660667
6FX5002-5DA11 5DA11 DESINA PVC 660244

Dimensions and specifications may be changed without prior notice.

844
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for mobile use
Base line for use on SIEMENS drive systems

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled motor
flexing -20C to +60C Bare copper, extra fine wire conductor connection cable is specially manufactured
fixed installation -50C to +80C acc. to DIN VDE 0295 cl.6 for applications with mobile use.
Minimum bending radius high quality PP core insulation The special PUR outer sheath
flexing 10x cable Core identification U/L1/C/L+ allows use in many industrial
fixed installation 7x cable V/L2 environments of general machine
Max. acceleration W/L3/D/L- and plant construction.
5 m/s GN-YE conductor
Bending cycles Signal cores Characteristic
10 million for 12x cable Copper conductors, bare These pre-assembled cables can be
Operating voltage High quality PP core insulation produced in any lengths and also with
VDE U0/U 600/1000 V Core identification black customer-specific modifications.
UL 1000 V white
Test voltage Cores twisted in pairs Note
power cores 4 kV Shielding screened with tin-plated
Please observe the installation instructions
control cores 2 kV copper wires
for laying cables in cable carriers and
Insulation resistance 500 MOhm x km Complete shield of tin-plated copper
the drive or controller manufacturer's
braiding, coverage approx. 80%
information about maximum permitted
Approbations PUR outer sheath
cable length.
DESINA (ISO 23570) Sheath colour orange (RAL 2003)
The prefabricated cables listed here are not
VDE original parts, but accessories manufactured
UL/CSA by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
6FX8002-5CA01 5CA01 DESINA PUR 660053 6FX8002-5DA21 5DA21 DESINA PUR 660076
6FX8002-5CA11 5CA11 DESINA PUR 660056 6FX8002-5DA31 5DA31 DESINA PUR 660080
6FX8002-5CA21 5CA21 DESINA PUR 660059 6FX8002-5DA41 5DA41 DESINA PUR 660084
6FX8002-5CA31 5CA31 DESINA PUR 660063 6FX8002-5DA51 5DA51 DESINA PUR 660088
6FX8002-5CA41 5CA41 DESINA PUR 660066 6FX8002-5DA61 5DA61 DESINA PUR 660089
6FX8002-5CA51 5CA51 DESINA PUR 660067 6FX8002-5DA13 5DA13 DESINA PUR 89800
6FX8002-5CA61 5CA61 DESINA PUR 660068 6FX8002-5DA23 5DA23 DESINA PUR 89802
6FX8002-5CA13 5CA13 DESINA PUR 660058 6FX8002-5DA33 5DA33 DESINA PUR 660082
6FX8002-5CA23 5CA23 DESINA PUR 660061 6FX8002-5DA43 5DA43 DESINA PUR 660085
6FX8002-5DA01 5DA01 DESINA PUR 660070 6FX8002-5DA53 5DA53 DESINA PUR 660668
6FX8002-5DA11 5DA11 DESINA PUR 660073

Dimensions and specifications may be changed without prior notice.

845
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for fixed laying
Base line for use on SIEMENS drive systems

Technical data Cable structure Application


Temperature range Tinned copper conductors This high quality pre-assembled
-20C to +80C Polyolefin polymer core insulation feedback cable is specially manufactured
Minimum bending radius Complete shield of tin-plated copper for applications with static installation.
18x cable braiding, coverage approx. 80% The special PVC outer sheath
Max. acceleration PVC outer sheath allows use in many industrial
2 m/s Sheath colour green environments of general machine
Bending cycles Structure(3x(2x0,14)+4x0,14+2x0,5) and plant construction.
100,000 3 pairs with tin-plated copper wires,
Max. operating voltage 30 V AC coverage approx. 90% Characteristic
Test voltage 500 V Colour code Economical alternatives to the cable
Insulation resistance 100 MOhm x km Pair 1: YE+GN carrier compatible cable types which
Pair 2: BK+BN otherwise meet all requirements of
Approbations Pair 3: RD+OG the servo drive manufacturers.
DESINA (ISO 23570) Quad 1: GY+BU+WH/YE+BK/WH These pre-assembled cables can be
UL/CSA Pair 4: BN/RD+BN/BU produced in any lengths and also with
Structure(3x(2x0,14)+4x0,14+4x0,22+2x0,5) customer-specific modifications.
3 pairs with tin-plated copper wires,
coverage approx. 90% Note
Colour code
Please observe the drive or controller
Pair 1: YE+GN
manufacturer's information about
Pair 2: BK+BN
maximum permitted cable length.
Pair 3: RD+OG
The prefabricated cables listed here are not
Quad 1: GY+BU+WH/YE+BK/WH
original parts, but accessories manufactured
Quad 2: BN/YE+BN/GY+GN/BK+RD/GN
by the company HELUKABEL GmbH.
Pair 4: BN/RD+BN/BU
The data, standards and approvals relate
Structure(4x2x0,34+4x0,5)
solely to the bulk goods used.
Colour code
Pair 1: BU+VT
Pair 2: BN+BK
Pair 3: RD+OG
Pair 4: YE+GN
Quad: YE/WH+RD/WH+BU/WH+BK/WH

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
6FX5002-2AD00 2AD00 DESINA PVC 660207 6FX5002-2CC11 2CC11 DESINA PVC 660670
6FX5002-2AH00 2AH00 DESINA PVC 660209 6FX5002-2CD01 2CD01 DESINA PVC 660671
6FX5002-2CA11 2CA11 DESINA PVC 660210 6FX5002-2CF02 2CF02 DESINA PVC 660219
6FX5002-2CA15 2CA15 DESINA PVC 660211 6FX5002-2CG00 2CG00 DESINA PVC 660672
6FX5002-2CA31 2CA31 DESINA PVC 660212 6FX5002-2CH00 2CH00 DESINA PVC 660220
6FX5002-2CA51 2CA51 DESINA PVC 660214 6FX5002-2EQ10 2EQ10 DESINA PVC 660222
6FX5002-2CA61 2CA61 DESINA PVC 660215 6FX5002-2CE02 2CE02 DESINA PVC 660673
6FX5002-2CA72 2CA72 DESINA PVC 660669 6FX5002-2CM00 2CM00 DESINA PVC 660674
6FX5002-2CB51 2CB51 DESINA PVC 660217 6FX5002-2CE07 2CE07 DESINA PVC 660675

Dimensions and specifications may be changed without prior notice.

846
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for mobile use
Base line for use on SIEMENS drive systems

Technical data Cable structure Application


Temperature range Tinned copper conductors This high quality pre-assembled
flexing -20C to +60C high quality PP core insulation feedback cable is specially manufactured
fixed installation -50C to +80C Complete shield of tin-plated copper for applications with mobile use.
Minimum bending radius braiding, coverage approx. 80% The special PUR outer sheath
flexing 11x cable PUR outer sheath allows use in many industrial
fixed installation 7x cable Sheath colour green environments of general machine
Max. acceleration Structure/colour code and plant construction.
5 m/s (2x2x0,18)
Bending cycles BK, BN, RD, OG Characteristic
10 million for 12x cable (4x2x0,18) These pre-assembled cables can be
Operating voltage 30 V BK+BN, RD+OG, YE+GN, BU+VT produced in any lengths and also with
Test voltage 500 V (8x2x0,18) customer-specific modifications.
Insulation resistance 10 MOhm x km BK+BN, RD+OG, YE+GN, BU+VT,
GY+WH, WH/BK+WH/BN, Note
Approbations WH/RD+WH/OG, WH/YE+WH/GN
Please observe the installation instructions
DESINA (ISO 23570) (12x0,22)
for laying cables in cable carriers and
UL/CSA BK, BN, RD, OG, YE, GN, BU, VT,
the drive or controller manufacturer's
GY, WH, WH/BK, WH/BN
information about maximum permitted
(4x2x0,34+4x0,5)
cable length.
RD+OG, YE+GN, BU+VT,
The prefabricated cables listed here are not
BK+BN, WH/RD, WH/YE, WH/BU, WH/BK
original parts, but accessories manufactured
(3x(2x0,14)+2x(0,5))
by the company HELUKABEL GmbH.
RD+OG, YE+GN, BK+BN, BK, RD
The data, standards and approvals relate
(3x(2x0,14)+2x0,5+4x0,14)
solely to the bulk goods used.
RD+OG, YE+GN, BK+BN, BN/RD, BN/BU,
GY, BU, WH/YE, WH/BK
(3x(2x0,14)+2x0,5+4x0,14+4x0,22)
RD+OG, YE+GN, BK+BN, BN/RD, BN/BU,
GY, BU, WH/YE, WH/BK, BN/YE,
BN/GY/GN/BK, GN/RD

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
6FX8002-2AD00 2AD00 DESINA PUR 660014 6FX8002-2CC11 2CC11 DESINA PUR 660032
6FX8002-2AH00 2AH00 DESINA PUR 87328 6FX8002-2CD01 2CD01 DESINA PUR 660033
6FX8002-2CA11 2CA11 DESINA PUR 660018 6FX8002-2CF02 2CF02 DESINA PUR 89293
6FX8002-2CA15 2CA15 DESINA PUR 660019 6FX8002-2CG00 2CG00 DESINA PUR 660034
6FX8002-2CA31 2CA31 DESINA PUR 660021 6FX8002-2CH00 2CH00 DESINA PUR 660035
6FX8002-2CA51 2CA51 DESINA PUR 660023 6FX8002-2EQ10 2EQ10 PUR DESINA 660038
6FX8002-2CA61 2CA61 DESINA PUR 660024 6FX8002-2CA21 2CA21 DESINA PUR 660020
6FX8002-2CA72 2CA72 DESINA PUR 660676 6FX8002-2CE02 2CE02 DESINA PUR 660677
6FX8002-2CB31 2CB31 DESINA PUR 650122 6FX8002-2CM00 2CM00 DESINA PUR 660678
6FX8002-2CB51 2CB51 DESINA PUR 660031 6FX8002-2CE07 2CE07 DESINA PUR 660679

U
Dimensions and specifications may be changed without prior notice.

847
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for fixed laying
Base line for use on SIEMENS drive systems (Drive Cliq*)

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled motor
flexing 0C to +60C Bare copper, acc. to IEC 60228 cl.6 connection cable is specially manufactured
fixed installation -20C to +80C PVC core insulation for applications with static installation.
Minimum bending radius Core identification U/L1/C/L+ The special PVC outer sheath
flexing 20x cable V/L2 allows use in many industrial
fixed installation 5x cable W/L3/D/L- environments of general machine
Max. acceleration GN-YE conductor and plant construction.
2 m/s Signal cores
Bending cycles Copper conductors, bare Characteristic
100,000 for 20x cable TPE-E core insulation Economical alternatives to the cable
Nominal voltage VDE Core identification black, white carrier compatible cable types which
(power) U0/U 0,6/1 kV Cores twisted in pairs otherwise meet all requirements of
(signal) 24 V Shield tin-plated copper braiding the servo drive manufacturers.
Nominal voltage UL/CSA Complete shield of tin-plated copper These pre-assembled cables can be
(power + signal) 1000 V braiding, coverage approx. 80% produced in any lengths and also with
Test voltage PVC outer sheath customer-specific modifications.
power cores 4 kV Sheath colour orange (RAL 2003)
signal cores 1 kV Note
Insulation resistance 20 MOhm x km
Please observe the drive or controller
manufacturer's information about
Approbations maximum permitted cable length.
DESINA (ISO 23570) The prefabricated cables listed here are not
VDE original parts, but accessories manufactured
UL/CSA by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.
* Drive Cliq is registered trademark
from Siemens AG.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
6FX5002-5CS01 5CS01 DESINA PVC 660855 6FX5002-5DS01 5DS01 DESINA PVC 660863
6FX5002-5CS11 5CS11 DESINA PVC 660856 6FX5002-5DS11 5DS11 DESINA PVC 660864
6FX5002-5CS21 5CS21 DESINA PVC 660857 6FX5002-5DS21 5DS21 DESINA PVC 660865
6FX5002-5CS31 5CS31 DESINA PVC 660858 6FX5002-5DS31 5DS31 DESINA PVC 660866
6FX5002-5CS41 5CS41 DESINA PVC 660859 6FX5002-5DS41 5DS41 DESINA PVC 660867
6FX5002-5CS51 5CS51 DESINA PVC 660860 6FX5002-5DS51 5DS51 DESINA PVC 660868
6FX5002-5CS61 5CS61 DESINA PVC 660861 6FX5002-5DS61 5DS61 DESINA PVC 660869
6FX5002-5CS13 5CS13 DESINA PVC 660862 6FX5002-5DS13 5DS13 DESINA PVC 660870

Dimensions and specifications may be changed without prior notice.


* Drive Cliq is registered trademark from Siemens AG.

848
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for mobile use
Base line for use on SIEMENS drive systems (Drive Cliq*)

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled motor
flexing -20C to +60C Bare copper, extra fine wire conductor connection cable is specially manufactured
fixed installation -50C to +80C acc. to DIN VDE 0295 cl.6 for applications with mobile use.
Minimum bending radius high quality PP core insulation The special PUR outer sheath
flexing 10x cable Core identification U/L1/C/L+ allows use in many industrial
fixed installation 7x cable V/L2 environments of general machine
Max. acceleration W/L3/D/L- and plant construction.
5 m/s GN-YE conductor
Bending cycles Signal cores Characteristic
10 million for 12x cable Copper conductors, bare These pre-assembled cables can be
Operating voltage High quality PP core insulation produced in any lengths and also with
VDE U0/U 600/1000 V Core identification black, white customer-specific modifications.
UL 1000 V Cores twisted in pairs
Test voltage Shielding screened with tin-plated copper Note
power cores 4 kV wires
Please observe the installation instructions
signal cores 2 kV Complete shield of tin-plated copper
for laying cables in cable carriers and
Insulation resistance 500 MOhm x km braiding, coverage approx. 80%
the drive or controller manufacturer's
PUR outer sheath
information about maximum permitted
Approbations Sheath colour orange (RAL 2003)
cable length.
DESINA (ISO 23570) The prefabricated cables listed here are not
UL/CSA original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.
* Drive Cliq is registered trademark
from Siemens AG.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
6FX8002-5CS01 5CS01 DESINA PUR 660871 6FX8002-5DS01 5DS01 DESINA PUR 660879
6FX8002-5CS11 5CS11 DESINA PUR 660872 6FX8002-5DS11 5DS11 DESINA PUR 660880
6FX8002-5CS21 5CS21 DESINA PUR 660873 6FX8002-5DS21 5DS21 DESINA PUR 660881
6FX8002-5CS31 5CS31 DESINA PUR 660874 6FX8002-5DS31 5DS31 DESINA PUR 660882
6FX8002-5CS41 5CS41 DESINA PUR 660875 6FX8002-5DS41 5DS41 DESINA PUR 660883
6FX8002-5CS51 5CS51 DESINA PUR 660876 6FX8002-5DS51 5DS51 DESINA PUR 660884
6FX8002-5CS61 5CS61 DESINA PUR 660877 6FX8002-5DS61 5DS61 DESINA PUR 660885
6FX8002-5CS13 5CS13 DESINA PUR 660878 6FX8002-5DS13 5DS13 DESINA PUR 660886

Dimensions and specifications may be changed without prior notice.


* Drive Cliq is registered trademark from Siemens AG.

849
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for fixed laying
Base line for use on SIEMENS drive systems (Drive Cliq*)

Technical data Cable structure Application


Temperature range Bare copper conductor, 7 strands This high quality pre-assembled
flexing -20C to +60C Polyolefin core insulation feedback cable is specially manufactured
fixed installation -20C to +80C Complete shield aluminium foil coated for applications with static installation.
Minimum bending radius with plastic, braiding of tin-plated copper The special PVC outer sheath
flexing 10x cable wires, coverage approx. 85% allows use in many industrial
fixed installation 5x cable PUR outer sheath environments of general machine
Max. acceleration Sheath colour green and plant construction.
2 m/s Structure/colour code
Bending cycles (2xAWG22+2x2xAWG26) Characteristic
100.000 for 10x cable Colour code Economical alternatives to the cable
max. operating voltage 30 V AC (UL) Pair AWG22: RD+BK carrier compatible cable types which
Test voltage 500 V / 50 Hz / 1min Pair 1 AWG26: YW+GN otherwise meet all requirements of
Insulation resistance 1 GOhm x km Pair 2 AWG26: PK+BU the servo drive manufacturers.
Conductor resistance Connector data These pre-assembled cables can be
Core AWG26 135 ohms/km RJ45 connector CAT5 produced in any lengths and also with
Core AWG22 62 ohms/km Material: nickel-plated PBT/brass customer-specific modifications.
Characteristic impedance AWG26 pairs Contacts 30u" Au/Ni
from 1 MHz to 100 MHz 100+/-15 Ohm Rated voltage: 50 V DC / 35 V AC Note
Operating capacitance AWG26 pairs Operating temperature: -20C to + 120C
Please observe the drive or controller
for 800 Hz rated 50 nF/km Mating cycles: 1000
manufacturer's information about
Cover
maximum permitted cable length.
Approbations zinc die-cast
The prefabricated cables listed here are not
UL/CSA zinc die-cast / PBT blue
original parts, but accessories manufactured
PBT blue
by the company HELUKABEL GmbH.
PBT black
The data, standards and approvals relate
solely to the bulk goods used.
* Drive Cliq is registered trademark
from Siemens AG.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
6FX5002-2DC00 2DC00 DESINA PUR 660887 6FX5002-2DC20 2DC20 DESINA PUR 660889
6FX5002-2DC10 2DC10 DESINA PUR 660888

Dimensions and specifications may be changed without prior notice.


* Drive Cliq is registered trademark from Siemens AG.

850
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for mobile use
Base line for use on SIEMENS drive systems (Drive Cliq*)

Technical data Cable structure Application


Temperature range 0,15 mm Bare copper conductor, 19 strands This high quality pre-assembled
flexing -20C to +60C 0,38 mm Tin-plated copper conductor, feedback cable is specially manufactured
fixed installation -20C to +80C 19 strands for applications with mobile use.
Minimum bending radius Polyolefin core insulation The special PUR outer sheath
flexing 15x cable Complete shield aluminium foil coated allows use in many industrial
fixed installation 5x cable with plastic, braiding of tin-plated copper environments of general machine
Max. acceleration wires, coverage approx. 85% and plant construction.
5 m/s PUR outer sheath
Bending cycles Sheath colour green Characteristic
2 million for 15x cable Structure/colour code These pre-assembled cables can be
max. operating voltage 30 V (2x0,38mm)+2x(2x0,15mm) produced in any lengths and also with
Test voltage 500 V / 50 Hz / 1min Colour code customer-specific modifications.
Insulation resistance 1 GOhm x km Pair 0,38 mm: RD+BK
Conductor resistance Pair 1 0,15 mm: YE+GN Note
Core AWG26 135 ohms/km Pair 2 0,15 mm: PK+BU
Please observe the installation instructions
Core AWG22 62 ohms/km Connector data
for laying cables in cable carriers and
Characteristic impedance 0,15 mm RJ45 connector CAT5
the drive or controller manufacturer's
pairs Material: nickel-plated PBT/brass
information about maximum permitted
from 1 MHz to 100 MHz 100+/-15 Ohm Contacts 30u" Au/Ni
cable length.
Operating capacitance 0,15 mm pairs Rated voltage: 50 V DC / 35 V AC
The prefabricated cables listed here are not
for 800 Hz rated 50 nF/km Operating temperature: -20C to + 120C
original parts, but accessories manufactured
Mating cycles: 1000
by the company HELUKABEL GmbH.
Approbations Cover
The data, standards and approvals relate
UL/CSA zinc die-cast
solely to the bulk goods used.
zinc die-cast / PBT blue
* Drive Cliq is registered trademark
PBT blue
from Siemens AG.
PBT black

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
6FX8002-2DC00 2DC00 DESINA PUR 660890 6FX8002-2DC20 2DC20 DESINA PUR 660892
6FX8002-2DC10 2DC10 DESINA PUR 660891

Dimensions and specifications may be changed without prior notice.


* Drive Cliq is registered trademark from Siemens AG.

851
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for mobile use (PVC)
Base line for use on REXROTH drive systems

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled
flexing -30C to +80C Bare copper, extra fine wire conductor motor connection cable is specially
fixed installation -50C to +90C acc. to DIN VDE 0295 cl.6 manufactured for applications with
Minimum bending radius PETP core insulation high mechanical stress.
flexing 10x cable Core identification 1, 2, 3 The special PVC outer sheath
fixed installation 7x cable GN-YE conductor allows use in many industrial
Max. acceleration Signal cores environments of general machine
4 m/s Bare copper, extra fine wire conductor and plant construction.
Bending cycles acc. to DIN VDE 0295 cl.6
5 million for 10x cable Core insulation PETP Characteristic
Nominal voltage Core identification Particularly suitable for use with
UL/CSA 1000 V Pair 1: 5. 6 small bending radii and high
Test voltage Pair 2: 7. 8 acceleration.
power cores 4 kV Cores twisted in pairs These pre-assembled cables can be
signal cores 2 kV Shielding aluminium/polyester foil produced in any lengths and also with
Insulation resistance 20 MOhm x km Drain wire customer-specific modifications.
tin-plated copper braiding
Approbations Complete shield of tin-plated copper Note
DESINA (ISO 23570) braiding, coverage approx. 85%
Please observe the installation instructions
UL/CSA PVC outer sheath
for laying cables in cable carriers and
Sheath colour orange (RAL 2003)
the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel Helukabel Helukabel


Designation Part no. Designation Part no.
motor cable 4009 PVC 660680 motor cable 4020 PVC 660685
motor cable 4017 PVC 660681 motor cable 4018 PVC 660686
motor cable 4039 PVC 660682 motor cable 4016 PVC 660687
motor cable 4060 PVC 660683 motor cable 4119 PVC 660688
motor cable 4055 PVC 660684

Dimensions and specifications may be changed without prior notice.

852
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for mobile use (PUR)
Base line for use on REXROTH drive systems

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled
flexing -20C to +60C Bare copper, extra fine wire conductor motor connection cable is specially
fixed installation -50C to +80C acc. to DIN VDE 0295 cl.6 manufactured for applications with
Minimum bending radius PETP core insulation or high quality high mechanical stress.
flexing 10x cable PP core insulation The special PUR outer sheath
fixed installation 7x cable Core identification 1, 2, 3 allows use in many industrial
Max. acceleration GN-YE conductor environments of general machine
5 m/s Signal cores and plant construction.
Bending cycles Bare copper, extra fine wire conductor
5 million for 10x cable acc. to DIN VDE 0295 cl.6 Characteristic
Nominal voltage PETP or high quality PP core insulation Particularly suitable for use with
UL/CSA 1000 V Core identification small bending radii and high
Test voltage Pair 1: 5, 6 acceleration.
power cores 4 kV Pair 2: 7, 8 These pre-assembled cables can be
signal cores 2 kV Cores twisted in pairs produced in any lengths and also with
Insulation resistance 10 MOhm x km Shielding aluminium/polyester foil customer-specific modifications.
Drain wire
Approbations tin-plated copper braiding Note
DESINA (ISO 23570) Complete shield of tin-plated copper
Please observe the installation instructions
UL/CSA braiding, coverage approx. 80%
for laying cables in cable carriers and
PUR outer sheath
the drive or controller manufacturer's
Sheath colour orange (RAL 2003)
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
IKG4008 motor cable 4008 PUR 660090 IKG4130 motor cable 4130 PUR 660125
IKG4009 motor cable 4009 PUR 660091 IKG4127 motor cable 4127 PUR 660126
IKG4017 motor cable 4017 PUR 660092 IKG4143 motor cable 4143 PUR 660129
IKG4077 motor cable 4077 PUR 660093 IKG4150 motor cable 4150 PUR 660130
IKG4029 motor cable 4029 PUR 660095 IKG4147 motor cable 4147 PUR 660131
IKG4039 motor cable 4039 PUR 660096 IKG4163 motor cable 4163 PUR 660134
IKG4028 motor cable 4028 PUR 660097 IKG4170 motor cable 4170 PUR 660135
IKG4073 motor cable 4073 PUR 660099 IKG4167 motor cable 4167 PUR 660136
IKG4071 motor cable 4071 PUR 660100 IKG4183 motor cable 4183 PUR 660139
IKG4072 motor cable 4072 PUR 660101 IKG4200 motor cable 4200 PUR 660140
IKG4053 motor cable 4053 PUR 660103 IKG4186 motor cable 4186 PUR 660141
IKG4060 motor cable 4060 PUR 660104 IKG4203 motor cable 4203 PUR 660144
IKG4055 motor cable 4055 PUR 660105 IKG4210 motor cable 4210 PUR 660145

U
IKG4063 motor cable 4063 PUR 660108 IKG4204 motor cable 4204 PUR 660146
IKG4070 motor cable 4070 PUR 660109 IKG4223 motor cable 4223 PUR 660149
IKG4068 motor cable 4068 PUR 660110 IKG4224 motor cable 4224 PUR 660150
IKG4067 motor cable 4067 PUR 660111 IKG4013 motor cable 4013 PUR 660153
IKG4083 motor cable 4083 PUR 660114 IKG4020 motor cable 4020 PUR 660154
IKG4090 motor cable 4090 PUR 660115 IKG4018 motor cable 4018 PUR 660155
IKG4087 motor cable 4087 PUR 660116 IKG4016 motor cable 4016 PUR 660156
IKG4103 motor cable 4103 PUR 660119 IKG4033 motor cable 4033 PUR 660157
IKG4110 motor cable 4110 PUR 660120 IKG4050 motor cable 4050 PUR 660158
IKG4107 motor cable 4107 PUR 660121 IKG4035 motor cable 4035 PUR 660159
IKG4123 motor cable 4123 PUR 660124 IKG4037 motor cable 4037 PUR 660160

Continuation

853
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for mobile use (PUR)
Base line for use on REXROTH drive systems
Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel
Designation Designation Part no. Designation Designation Part no.
IKG4136 motor cable 4136 PUR 660689 RKL4313 motor cable 4313 PUR 660719
IKG4155 motor cable 4155 PUR 660690 RKL4314 motor cable 4314 PUR 660720
IKG4176 motor cable 4176 PUR 660691 RKL4315 motor cable 4315 PUR 660721
IKG4186 motor cable 4186 PUR 660692 RKL4317 motor cable 4317 PUR 660722
IKG4172 motor cable 4172 PUR 660693 RKL4318 motor cable 4318 PUR 660723
IKG4173 motor cable 4173 PUR 660694 RKL4401 motor cable 4401 PUR 660724
IKG4174 motor cable 4174 PUR 660695 RKL4421 motor cable 4421 PUR 660725
IKG4115 motor cable 4115 PUR 660696 RKL4431 motor cable 4431 PUR 660726
IKG4140 motor cable 4140 PUR 660697 RKL4441 motor cable 4441 PUR 660727
IKG4116 motor cable 4116 PUR 660698 RKL4421 motor cable 4421 PUR 660728
RKL4421 motor cable 4421 PUR 660699 RKL4421 motor cable 4421 PUR 660729
IKG4117 motor cable 4117 PUR 660700 RKL4421 motor cable 4421 PUR 660730
IKG4177 motor cable 4177 PUR 660701 RKL4421 motor cable 4421 PUR 660732
IKG4118 motor cable 4118 PUR 660702 RKL4421 motor cable 4421 PUR 660733
IKG4215 motor cable 4215 PUR 660703 RKL4421 motor cable 4421 PUR 660734
IKG4175 motor cable 4175 PUR 660704 RKL4421 motor cable 4421 PUR 660735
IKG4169 motor cable 4169 PUR 660705 RKL4421 motor cable 4421 PUR 660736
IKG4138 motor cable 4138 PUR 660706 RKL4421 motor cable 4421 PUR 660737
IKG4134 motor cable 4134 PUR 660707 RKL4421 motor cable 4421 PUR 660739
IKG4119 motor cable 4119 PUR 660708 RKL4421 motor cable 4421 PUR 660740
IKG4120 motor cable 4120 PUR 660709 RKL4421 motor cable 4421 PUR 660741
IKG4137 motor cable 4137 PUR 660710 RKL4421 motor cable 4421 PUR 660742
RKL4302 motor cable 4302 PUR 660627 RKL4421 motor cable 4421 PUR 660743
RKL4303 motor cable 4303 PUR 660711 RKL4421 motor cable 4421 PUR 660744
RKL4300 motor cable 4300 PUR 660712 RKL4421 motor cable 4421 PUR 660745
RKL4301 motor cable 4301 PUR 660713 RKL4421 motor cable 4421 PUR 660746
RKL4306 motor cable 4306 PUR 660714 RKL4421 motor cable 4421 PUR 660747
RKL4307 motor cable 4307 PUR 660715 RKL4421 motor cable 4421 PUR 660748
RKL4308 motor cable 4308 PUR 660716 RKL4421 motor cable 4421 PUR 660749
RKL4309 motor cable 4309 PUR 660717 RKL4421 motor cable 4421 PUR 660750
RKL4310 motor cable 4310 PUR 660718 RKL4421 motor cable 4421 PUR 660751

Dimensions and specifications may be changed without prior notice.

854
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for mobile use (PVC)
Base line for use on REXROTH drive systems

Technical data Cable structure Application


Temperature range Copper conductors This high quality pre-assembled
flexing -10C to +80C Polyolefin core insulation feedback cable is specially manufactured
fixed installation -40C to +80C Complete shield of tin-plated copper for applications with mobile use.
Minimum bending radius braiding, coverage approx. 85% The special PVC outer sheath
flexing 12x cable PVC outer sheath allows use in many industrial
fixed installation 8x cable Sheath colour orange environments of general machine
Max. acceleration Structure/colour code and plant construction.
4 m/s (2x0,5+4x2x0,25)
Bending cycles WH, BN, BN+GN, RD+BL, BU+VT, GY+PK Characteristic
5 million for 12x cable (2x1,0+4x2x0,25) Particularly suitable for use with
Operating voltage 30 V WH, BN, BN+GN, RD+BL, BU+VT, GY+PK small bending radii and high
Test voltage 1500 V acceleration.
Insulation resistance 100 MOhm x km These pre-assembled cables can be
produced in any lengths and also with
Approbations customer-specific modifications.
UL/CSA
Note
Please observe the installation instructions
for laying cables in cable carriers and
the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel Helukabel Helukabel


Designation Part no. Designation Part no.
feedback cables 4374 PVC 660752 feedback cables 4103 PVC 660755
feedback cables 4042 PVC 660753 feedback cables 4200 PVC 660756
feedback cables 4375 PVC 660754

Dimensions and specifications may be changed without prior notice.

855
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for mobile use (PUR)
Base line for use on REXROTH drive systems

Technical data Cable structure Application


Temperature range Copper conductors This high quality pre-assembled
flexing 0C to +60C high quality PP core insulation / feedback cable is specially manufactured
fixed installation -40C to +60C polyolefin core insulation for applications with mobile use.
Minimum bending radius Complete shield of tin-plated copper The special PUR outer sheath
flexing 10x cable braiding, coverage approx. 80% allows use in many industrial
fixed installation 8x cable PUR outer sheath environments of general machine
Max. acceleration Sheath colour orange and plant construction.
5 m/s (for (2x0,5+4x2x0,25) green also possible)
Bending cycles Structure/colour code Characteristic
10 million for 12x cable (2x0,5+4x2x0,25) Particularly suitable for use with
Operating voltage WH, BN, BN+GN, RD+BK, BU+VT, GY+PK small bending radii and high
VDE 300 V AC (2x1,0+4x2x0,25) acceleration.
UL/CSA 30 V WH, BN, BN+GN, RD+BK, BU+VT, GY+PK These pre-assembled cables can be
Test voltage 1000 V ( 0,14 mm 0,5 kV) (4x2x0,14+4x1,0+(4x0,14)) produced in any lengths and also with
Insulation resistance 100 MOhm x km GY+PK, YE+VT, GN+BN, RD+BK, BU, customer-specific modifications.
WH/GN, BN/GN, WH, GN/BK, BU/BK,
Approbations YE/BK, RD/BK Note
UL/CSA Please observe the installation instructions
for laying cables in cable carriers and
the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
IKS4374 feedback cables 4374 PUR 660260 IKS0205 feedback cables 0205 PUR 660275
IKS4042 feedback cables 4042 PUR 660757 IKS0204 feedback cables 0204 PUR 660276
IKS4375 feedback cables 4375 PUR 660263 IKS0206 feedback cables 0206 PUR 660277
IKS4040 feedback cables 4040 PUR 660758 IKS4142 feedback cables 4142 PUR 660283
IKS4041 feedback cables 4041 PUR 660759 IKS4038 feedback cables 4038 PUR 660761
IKS4020 feedback cables 4020 PUR 660266 IKS4001 feedback cables 4001 PUR 660313
IKS4043 feedback cables 4043 PUR 660760 IKS4019 feedback cables 4019 PUR 660314
IKS4103 feedback cables 4103 PUR 660272 RKG4200 feedback cables 4200 PUR 660628

Dimensions and specifications may be changed without prior notice.

856
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for fixed laying
Base line for use on LENZE drive systems of the type Global Drive

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled motor
flexing -20C to +70C Copper conductors, bare connection cable is specially manufactured
fixed installation -20C to +80C high quality PP core insulation for applications with static installation.
Minimum bending radius Core identification 1, 2, 3 The special PVC outer sheath
flexing 18x cable GN-YE conductor allows use in many industrial
fixed installation 9x cable Signal cores environments of general machine
Max. acceleration Copper conductors, bare and plant construction.
2 m/s High quality PP core insulation
Bending cycles Core identification black, white Characteristic
50.000 for 18x cable Shielding aluminium/polyester foil Economical alternatives to the cable
Nominal voltage U0/U 0,6/1 kV screened with tin-plated copper wires carrier compatible cable types which
Test voltage 4 kV Complete shield of tin-plated copper otherwise meet all requirements of
Insulation resistance 500 MOhm x km braiding, coverage approx. 80% the servo drive manufacturers.
PVC outer sheath These pre-assembled cables can be
Approbations Sheath colour orange (RAL 2003) produced in any lengths and also with
DESINA (ISO 23570) customer-specific modifications.
VDE
UL/CSA Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
EWLMxxxGM-015C motor cable GM 015 660334 EWLMxxxGM-100 motor cable GM 100 660738
EWLMxxxGM-015C motor cable GM 015 660482 EWLMxxxGM-040I motor cable GM 040I 660762
EWLMxxxGM-040 motor cable GM 040 660350 - motor cable GM 060I 660763
- motor cable GM 060 660731 EWLMxxxGM-100I motor cable GM 100I 660764

Dimensions and specifications may be changed without prior notice.

857
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for mobile use
Base line for use on LENZE drive systems of the type Global Drive

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled motor
flexing 0C to +60C Bare copper conductor connection cable is specially manufactured
fixed installation -30C to +80C acc. to DIN VDE 0295 cl.6 for applications with mobile use.
Minimum bending radius Polyolefin polymer core insulation The special PUR outer sheath
flexing 12x cable Core identification 1, 2, 3 allows use in many industrial
fixed installation 7x cable GN-YE conductor environments of general machine
Max. acceleration Signal cores and plant construction.
4 m/s Copper conductors, bare
Bending cycles Polyolefin/polymer core insulation Characteristic
10 million for 12x cable Core identification black, white Particularly suitable for use with
Operating voltage 1000 V Cores twisted in pairs small bending radii and high
Test voltage Shield,tin-plated copper braiding acceleration.
power cores 3 kV Complete shield of tin-plated copper These pre-assembled cables can be
control cores 1,5 kV braiding, coverage approx. 85% produced in any lengths and also with
Insulation resistance PUR outer sheath customer-specific modifications.
power cores 5000 MOhm x km Sheath colour orange (RAL 2003)
signal cores 20 MOhm x km Note
Please observe the installation instructions
Approbations for laying cables in cable carriers and
DESINA (ISO 23570) the drive or controller manufacturer's
UL/CSA information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
- motor cable GMS 015 660500 - motor cable GMS 100 660768
EWLMxxxGMS-025 motor cable GMS 025 660648 - motor cable GMS 040I 660769
EWLMxxxGMS-040 motor cable GMS 040 660766 - motor cable GMS 060I 660770
- motor cable GMS 060 660767 - motor cable GMS 100I 660771

Dimensions and specifications may be changed without prior notice.

858
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for fixed laying
Base line for use on LENZE drive systems of the type Global Drive

Technical data Cable structure Application


Temperature range Tinned copper conductors This high quality pre-assembled
fixed installation -25C to +80C PVC or PE core insulation feedback cable cable is specially manufactured
Minimum bending radius Shield of tin-plated copper braiding, for applications with static installation.
fixed installation 8x cable coverage approx. 75% The special PVC outer sheath
Operating voltage 30 V PVC outer sheath allows use in many industrial
Test voltage 1000 V Sheath colour green environments of general machine
Insulation resistance 10 MOhm x km Structure/colour code and plant construction.
(3x(2x0,14)+2x(0,5))
Approbations YE+BK, GN+BK, RD+BK, WH, BK Characteristic
DESINA (ISO 23570) (4x(2x0,14)+2x(1,0) Economical alternatives to the cable
UL/CSA YE+GN, PK+GY, RD+BU, BK+VT, WH, BN carrier compatible cable types which
otherwise meet all requirements of
the servo drive manufacturers.
These pre-assembled cables can be
produced in any lengths and also with
customer-specific modifications.

Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
EWLRxxxGM-T feedback cables GM-T 660335 EWLDxxxGGBS93 system cable GGBS 93 660773
EWLRxxxGM-T encoder cables GM-T 660772

Dimensions and specifications may be changed without prior notice.

859
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for mobile use
Base line for use on LENZE drive systems of the type Global Drive

Technical data Cable structure Application


Temperature range Tinned copper conductors This high quality pre-assembled
flexing -5C to +70C Polyester/polyolefin core insulation feedback cable is specially manufactured
fixed installation -40C to +80C Shield of tin-plated copper braiding, for applications with mobile use.
Minimum bending radius coverage approx. 80% The special PUR outer sheath
flexing 15x cable PUR outer sheath allows use in many industrial
fixed installation 8x cable Sheath colour green environments of general machine
Max. acceleration (0-000000-02866 orange) and plant construction.
3 m/s Structure/colour code
Bending cycles (3x(2x0,14)+2x(0,5)) Characteristic
2 million for 15x cable YE+BK, GN+BK, RD+BK, WH, BK These pre-assembled cables can be
Operating voltage 30 V (3x(2x0,14)+2x(0,5)) produced in any lengths and also with
Test voltage 1000 V YE+GN, PK+GY, RD+BU, WH, BN customer-specific modifications.
(4x(2x0,14)+2x(1,0)
Approbations YE+GN, PK+GY, RD+BU, BK+VT, WH, BN Note
DESINA (ISO 23570) (4x(2x0,14)+2x(0,5)
Please observe the installation instructions
UL/CSA YE+GN, PK+GY, RD+BU, BK+VT, WH, BN
for laying cables in cable carriers and
the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel Helukabel Helukabel


Designation Part no. Designation Part no.
feedback cables GMS-T 660445 encoder cables GMS-T 660774

Dimensions and specifications may be changed without prior notice.

860
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled fan cables


for fixed laying
Base line for use on LENZE drive systems of the type Global Drive

Technical data Cable structure Application


Temperature range Bare copper conductor, fine wire stranded This high quality pre-assembled
flexing -5C to +70C PVC core insulation fan cable is specially manufactured
fixed installation -40C to +70C Core identification 1, 2, 3 for applications with static installation.
Minimum bending radius GN-YE conductor The special PVC outer sheath
flexing 8x cable PVC outer sheath allows use in many industrial
fixed installation 4x cable Sheath colour grey environments of general machine
Nominal voltage and plant construction.
HAR U0/U 300/500 V
UL/CSA 600 V Characteristic
Test voltage power cores 3 kV Economical alternatives to the cable
Insulation resistance 20 MOhm x km carrier compatible cable types which
otherwise meet all requirements of
Approbations the servo drive manufacturers.
UL/CSA These pre-assembled cables can be
produced in any lengths and also with
customer-specific modifications.

Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel


Designation Designation Part no.
EWLLxxxGM fan cables GM 660351

Dimensions and specifications may be changed without prior notice.

861
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled fan cables


for mobile use
Base line for use on LENZE drive systems of the type Global Drive

Technical data Cable structure Application


Temperature range Copper conductors, bare, fine wire This high quality pre-assembled fan cable
flexing -5C to +80C stranded is specially manufactured for applications
fixed installation -40C to +80C PVC core insulation with mobile use.
Minimum bending radius Core identification 1, 2, 3 The special PUR outer sheath
flexing 8x cable GN-YE conductor allows use in many industrial
fixed installation 4x cable PUR outer sheath environments of general machine
Nominal voltage UL/CSA 600 V Sheath colour grey and plant construction.
Test voltage power cores 4 kV
Insulation resistance 20 MOhm x km Characteristic
Particularly suitable for use with
Approbations small bending radii and high
UL/CSA acceleration.
These pre-assembled cables can be
produced in any lengths and also with
customer-specific modifications.

Note
Please observe the installation instructions
for laying cables in cable carriers and
the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel


Designation Designation Part no.
EWLLxxxGMS fan cables GMS 660850

Dimensions and specifications may be changed without prior notice.

862
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for fixed laying
Base line for use on LENZE drive systems of the type L-force

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled motor
flexing -20C to +70C Copper conductors, bare connection cable is specially manufactured
fixed installation -20C to +80C high quality PP core insulation for applications with static installation.
Minimum bending radius Core identification 1, 2, 3 The special PVC outer sheath
flexing 18x cable GN-YE conductor allows use in many industrial
fixed installation 9x cable Signal cores environments of general machine
Max. acceleration Copper conductors, bare and plant construction.
2 m/s High quality PP core insulation
Bending cycles Core identification black, white Characteristic
50.000 for 18x cable Shielding aluminium/polyester foil Economical alternatives to the cable
Operating voltage screened with tin-plated copper wires carrier compatible cable types which
VDE U0/U 0,6/1 kV Complete shield of tin-plated copper otherwise meet all requirements of
Test voltage 4 kV braiding, coverage approx. 80% the servo drive manufacturers.
Insulation resistance 500 MOhm x km PVC outer sheath These pre-assembled cables can be
Sheath colour orange (RAL 2003) produced in any lengths and also with
Approbations customer-specific modifications.
DESINA (ISO 23570)
VDE Note
UL/CSA Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
EYP 0006 A xxxx C01 A00 motor cable 0006AC01A00 PVC 660776 EYP 0008 A xxxx M03 A00 motor cable 0008AM03A00 PVC 660781
EYP 0008 A xxxx C02 A00 motor cable 0008AC02A00 PVC 660777 EYP 0009 A xxxx M03 A00 motor cable 0009AM03A00 PVC 660782
EYP 0005 A xxxx M02 A00 motor cable 0005AM02A00 PVC 660778 EYP 0003 A xxxx M01 A00 motor cable 0003AM01A00 PVC 660783
EYP 0006 A xxxx M02 A00 motor cable 0006AM02A00 PVC 660779 EYP 0004 A xxxx M01 A00 motor cable 0004AM01A00 PVC 660784
EYP 0007 A xxxx M03 A00 motor cable 0007AM03A00 PVC 660780 EYP 0005 A xxxx M01 A00 motor cable 0005AM01A00 PVC 660785

Dimensions and specifications may be changed without prior notice.

863
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for mobile use
Base line for use on LENZE drive systems of the type L-force

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled motor
flexing 0C to +60C Bare copper conductor connection cable is specially manufactured
fixed installation -30C to +80C acc. to DIN VDE 0295 cl.6 for applications with mobile use.
Minimum bending radius Polyolefin polymer core insulation The special PUR outer sheath
flexing 12x cable Core identification 1, 2, 3 allows use in many industrial
fixed installation 7x cable GN-YE conductor environments of general machine
Max. acceleration Signal cores and plant construction.
4 m/s Copper conductors, bare
Bending cycles Polyolefin/polymer core insulation Characteristic
10 million for 12x cable Core identification black, white Particularly suitable for use with
Operating voltage 1000 V Cores twisted in pairs small bending radii and high
Test voltage Shielding screened with tin-plated acceleration.
power cores 3 kV copper wires These pre-assembled cables can be
control cores 1,5 kV Complete shield of tin-plated copper produced in any lengths and also with
Insulation resistance braiding, coverage approx. 85% customer-specific modifications.
power cores 5000 MOhm x km PUR outer sheath
signal cores 20 MOhm x km Sheath colour orange (RAL 2003) Note
Please observe the installation instructions
Approbations for laying cables in cable carriers and
DESINA (ISO 23570) the drive or controller manufacturer's
UL/CSA information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
EYP 0013 A xxxx C01 A00 motor cable 0013AC01A00 PUR 660786 EYP 0015 A xxxx M03 A00 motor cable 0015AM03A00 PUR 660791
EYP 0015 A xxxx C02 A00 motor cable 0015AC02A00 PUR 660787 EYP 0016 A xxxx M03 A00 motor cable 0016AM03A00 PUR 660792
EYP 0012 A xxxx M02 A00 motor cable 0012AM02A00 PUR 660788 EYP 0010 A xxxx M01 A00 motor cable 0010AM01A00 PUR 660793
EYP 0013 A xxxx M02 A00 motor cable 0013AM02A00 PUR 660789 EYP 0011 A xxxx M01 A00 motor cable 0011AM01A00 PUR 660510
EYP 0014 A xxxx M03 A00 motor cable 0014AM03A00 PUR 660790 EYP 0012 A xxxx M01 A00 motor cable 0012AM01A00 PUR 660794

Dimensions and specifications may be changed without prior notice.

864
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for fixed laying
Base line for use on LENZE drive systems of the type L-force

Technical data Cable structure Application


Temperature range Tinned copper conductors This high quality pre-assembled
fixed installation -25C to +80C PVC/polyolefin core insulation feedback cable is specially manufactured
Minimum bending radius Shield of tin-plated copper braiding, for applications with static installation.
fixed installation 8x cable coverage approx. 75% The special PVC outer sheath
Operating voltage 30 V PVC outer sheath allows use in many industrial
Test voltage 1000 V Sheath colour green environments of general machine
Insulation resistance 10 MOhm x km Structure/colour code and plant construction.
(3x(2x0,14)+2x(0,5))
Approbations YE+BK, GN+BK, RS+BK, WH, BK Characteristic
DESINA (ISO 23570) (4x(2x0,14)+2x(1,0) Economical alternatives to the cable
UL/CSA YE+GN, PK+GY, RD+BU, BK+VT, WH, BN carrier compatible cable types which
otherwise meet all requirements of
the servo drive manufacturers.
These pre-assembled cables can be
produced in any lengths and also with
customer-specific modifications.

Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
EYD 0017 A xxxx W01 S01 feedback cables 0017AW01S01 PVC 660795 EYF 0028 A xxxx A00 G02 feedback cables 0028AA00G02 PVC 660805
EYD 0017 A xxxx W01 S02 feedback cables 0017AW01S02 PVC 660796 EYF 0018 A xxxx A00 S03 feedback cables 0018AA00S03 PVC 660806
EYD 0017 A xxxx W01 W01 feedback cables 0017AW01W01 PVC 660797 EYF 0018 A xxxx A00 W02 feedback cables 0018AA00W02 PVC 660807
EYD 0017 A xxxx W03 S01 feedback cables 0017AW03S01 PVC 660798 EYF 0018 A xxxx F02 A00 feedback cables 0018AF02A00 PVC 660808
EYD 0017 A xxxx W03 S02 feedback cables 0017AW03S02 PVC 660799 EYF 0028 A xxxx F02 G02 feedback cables 0028AF02G02 PVC 660809
EYD 0017 A xxxx W03 W01 feedback cables 0017AW03W01 PVC 660800 EYF 0018 A xxxx F02 S03 feedback cables 0018AF02S03 PVC 660810
EYF 0017 A xxxx A00 S01 feedback cables 0017AA00S01 PVC 660801 EYF 0018 A xxxx F02 W02 feedback cables 0018AF02W02 PVC 660811
EYF 0017 A xxxx A00 S02 feedback cables 0017AA00S02 PVC 660802 EYF 0021 A xxxx A00 S03 feedback cables 0021AA00S03 PVC 660812
EYF 0017 A xxxx F01 A00 feedback cables 0017AF01A00 PVC 660803 EYF 0021 A xxxx F03 A00 feedback cables 0021AF03A00 PVC 660813
EYF 0017 A xxxx F01 S01 feedback cables 0017AF01S01 PVC 660630 EYF 0021 A xxxx F03 S03 feedback cables 0021AF03S03 PVC 660814
EYF 0017 A xxxx F01 S02 feedback cables 0017AF01S02 PVC 660804

Dimensions and specifications may be changed without prior notice.

865
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for mobile use
Base line for use on LENZE drive systems of the type L-force

Technical data Cable structure Application


Temperature range Tinned copper conductors This high quality pre-assembled
flexing -5C to +70C Polyester/polyolefin core insulation feedback cable is specially manufactured
fixed installation -40C to +80C Shield of tin-plated copper braiding, for applications with mobile use.
Minimum bending radius coverage approx. 80% The special PUR outer sheath
flexing 15x cable PUR outer sheath allows use in many industrial
fixed installation 8x cable Sheath colour green environments of general machine
Max. acceleration Structure/colour code and plant construction.
3 m/s (3x(2x0,14)+2x(0,5))
Bending cycles YE+BK, GN+BK, RD+BK, WH, BK Characteristic
2 million for 15x cable (3x(2x0,14)+2x(0,5)) These pre-assembled cables can be
Operating voltage 30 V YE+GN, PK+GY, RD+BU, WH, BN produced in any lengths and also with
Test voltage 1000 V (4x(2x0,14)+2x(1,0) customer-specific modifications.
YE+GN, PK+GY, RD+BU, BK+VT, WH, BN
Approbations (4x(2x0,14)+2x(0,5) Note
DESINA (ISO 23570) (except YE+GN, PK+GY, RD+BU, BK+VT, WH, BN
Please observe the installation instructions
0-000000-02866) for laying cables in cable carriers and
UL/CSA the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
EYD 0019 A xxxx F02 A00 feedback cables 0019AF02A00 PUR 660815 EYF 0020 A xxxx F01 S01 feedback cables 0020AF01S01 PUR 660819
EYD 0020 A xxxx A00 S04 feedback cables 0020AA00S04 PUR 660816 EYF 0020 A xxxx F01 S02 feedback cables 0020AF01S02 PUR 660820
EYF 0020 A xxxx A00 S05 feedback cables 0020AA00S05 PUR 660817 EYF 0022 A xxxx F03 A00 feedback cables 0022AF03A00 PUR 660821
EYF 0020 A xxxx F01 A00 feedback cables 0020AF01A00 PUR 660818

Dimensions and specifications may be changed without prior notice.

866
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled fan cables


for fixed laying
Base line for use on LENZE drive systems of the type L-force

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled fan cable
flexing -5C to +70C Bare copper conductor, fine wire stranded is specially manufactured for applications
fixed installation -40C to +70C PVC core insulation with static installation.
Minimum bending radius Core identification numbers The special PVC outer sheath
flexing 8x cable GN-YE conductor allows use in many industrial
fixed installation 4x cable PVC outer sheath environments of general machine
Nominal voltage Sheath colour grey and plant construction.
HAR U0/U 300/500 V
UL/CSA 600 V Characteristic
Test voltage power cores 3 kV Economical alternatives to the cable
Insulation resistance 20 MOhm x km carrier compatible cable types which
otherwise meet all requirements of
Approbations the servo drive manufacturers.
UL/CSA These pre-assembled cables can be
produced in any lengths and also with
customer-specific modifications.

Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
EYL 0001 A xxxx L01 A00 fan cables 0001AL01A00 PVC 660851 EYL 0001 A xxxx L02 A00 fan cables 0001AL02A00 PVC 660852

Dimensions and specifications may be changed without prior notice.

867
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled fan cables


for mobile use
Base line for use on LENZE drive systems of the type L-force

Technical data Cable structure Application


Temperature range Copper conductors, bare, fine wire stranded This high quality pre-assembled fan cable
flexing -5C to +80C TPE/PVC core insulation is specially manufactured for applications
fixed installation -40C to +80C Core identification 1, 2, 3 with mobile use.
Minimum bending radius GN-YE conductor The special PUR outer sheath
flexing 8x cable PUR outer sheath allows use in many industrial
fixed installation 4x cable Sheath colour grey environments of general machine
Nominal voltage UL/CSA 600 V and plant construction.
Test voltage power cores 4 kV
Insulation resistance 20 MOhm x km Characteristic
Particularly suitable for use with
Approbations small bending radii and high
UL/CSA acceleration.
These pre-assembled cables can be
produced in any lengths and also with
customer-specific modifications.

Note
Please observe the installation instructions
for laying cables in cable carriers and
the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Manufacturer Helukabel Helukabel Manufacturer Helukabel Helukabel


Designation Designation Part no. Designation Designation Part no.
EYL 0002 A xxxx L01 A00 fan cables 0001AL01A00 PVC 660853 EYL 0002 A xxxx L02 A00 fan cables 0002AL02A00 PVC 660854

Dimensions and specifications may be changed without prior notice.

868
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for fixed laying
Base line for use on SEW drive systems

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled motor
fixed installation -40C to +80C Copper conductors, bare connection cable is specially manufactured
Minimum bending radius PP core insulation for applications with static installation.
fixed installation 20x cable Core identification U1, V2, W3 The special PVC outer sheath
Nominal voltage GN-YE conductor allows use in many industrial
VDE 0,6/1 kV Signal cores environments of general machine
UL 1000 V Copper conductors, bare and plant construction.
Test voltage 4 kV PP core insulation
Insulation resistance 20 MOhm x km Core identification 1, 2, 3 Characteristic
Cores twisted to triple Economical alternatives to the cable
Approbations Shielding aluminium coated polyester foil carrier compatible cable types which
DESINA (ISO 23570) with drain wire + copper screen otherwise meet all requirements of
UL/CSA Complete shield of tin-plated copper the servo drive manufacturers.
braiding, coverage approx. 85% These pre-assembled cables can be
PVC outer sheath produced in any lengths and also with
Sheath colour orange (RAL 2003) customer-specific modifications.

Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel Helukabel Helukabel


Designation Part no. Designation Part no.
motor cable 1991795 PVC 4x1,5 660822 motor cable 1991914 PVC 4x2,5+3x1 660897
motor cable 1991892 PVC 4x1,5+3x1 660823

Dimensions and specifications may be changed without prior notice.

869
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for mobile use
Base line for use on SEW drive systems

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled
flexing -20C to +60C Bare copper, extra fine wire conductor motor connection cable is specially
fixed installation -50C to +80C acc. to DIN VDE 0295 cl.6 manufactured for applications with
Minimum bending radius high quality PP core insulation high mechanical stress.
flexing 10x cable Core identification U/L1/C/L+ The special PUR outer sheath
fixed installation 3x cable V/L2 allows use in many industrial
Max. acceleration W/L3/D/L- environments of general machine
20 m/s GN-YE conductor and plant construction.
Bending cycles Signal cores
5 million for 10x cable Copper conductors, bare, fine wire stranded Characteristic
Operating voltage High quality PP core insulation Particularly suitable for use with
power cores U0/U 600/1000 V Core identification 1, 2, 3 small bending radii and high
control cores 1000 V AC Cores twisted to triple acceleration.
Test voltage Shield tin-plated copper braiding These pre-assembled cables can be
power cores 4 kV Complete shield of tin-plated copper produced in any lengths and also with
control cores 4 kV braiding, coverage approx. 85% customer-specific modifications.
Insulation resistance 100 MOhm x km PUR outer sheath
Sheath colour orange (RAL 2003) Note
Approbations Please observe the installation instructions
DESINA (ISO 23570) for laying cables in cable carriers and
UL/CSA the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel Helukabel Helukabel


Designation Part no. Designation Part no.
motor cable 1991809 PUR 4x1,5 660824 motor cable 1991906 PUR 4x1,5+3x1 660829
motor cable 1991825 PUR 4x2,5 660825 motor cable 1991922 PUR 4x2,5+3x1 660830
motor cable 1991841 PUR 4x4 660826 motor cable 1991949 PUR 4x4+3x1 660831
motor cable 1991868 PUR 4x6 660827 motor cable 1991965 PUR 4x6+3x1 660832
motor cable 1991884 PUR 4x10 660828 motor cable 1991981 PUR 4x10+3x1 660833

Dimensions and specifications may be changed without prior notice.

870
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for fixed laying
Base line for use on SEW drive systems

Technical data Cable structure Application


Temperature range Power supply cores This high quality pre-assembled
fixed installation -40C to +80C Copper conductors, bare feedback cable is specially manufactured
Minimum bending radius PP core insulation for applications with static installation.
fixed installation 20x cable Core identification acc. to DIN 47100 The special PVC outer sheath
Nominal voltage max. 350 V, Complete shield of tin-plated copper allows use in many industrial
acc. to UL 300 V braiding with drain wire, environments of general machine
Test voltage coverage approx. 85% and plant construction.
core/core 1,5 kV PVC outer sheath
core/shield 1 kV Sheath colour green Characteristic
Economical alternatives to the cable
Approbations carrier compatible cable types which
DESINA (ISO 23570) otherwise meet all requirements of
UL/CSA the servo drive manufacturers.
These pre-assembled cables can be
produced in any lengths and also with
customer-specific modifications.

Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel Helukabel Helukabel


Designation Part no. Designation Part no.
feedback cables HF 13324535 PVC 6x2x0,25 660834 feedback cables 1994875 PVC 5x2x0,25 660836
feedback extension HF 1995391 PVC 6x2x0,25 660835 feedback extension 1995421 PVC 5x2x0,25 660837

Dimensions and specifications may be changed without prior notice.

871
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


for mobile use
Base line for use on SEW drive systems

Technical data Cable structure Application


Temperature range Copper conductors, bare This high quality pre-assembled
flexing -20C to +60C PP core insulation feedback cable is specially manufactured
fixed installation -50C to +80C TPE inner sheath for applications with mobile use.
Minimum bending radius Complete shield of tin-plated copper The special PUR outer sheath
flexing 10x cable braiding, coverage approx. 80% allows use in many industrial
fixed installation 5x cable PUR outer sheath environments of general machine
Max. acceleration Sheath colour green and plant construction.
20 m/s Core identification acc. to DIN 47100
Bending cycles Characteristic
10 million for 10x cable Particularly suitable for use with
Nominal voltage 300 V small bending radii and high
Test voltage 1,5 kV acceleration.
These pre-assembled cables can be
Approbations produced in any lengths and also with
DESINA (ISO 23570) customer-specific modifications.
UL/CSA
Note
Please observe the installation instructions
for laying cables in cable carriers and
the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel Helukabel Helukabel


Designation Part no. Designation Part no.
feedback cables HF 13324551 PUR 6x2x0,25 660838 feedback cables 1994875 PVC 5x2x0,25 660840
feedback extension HF 1995405 PUR 6x2x0,25 660839 feedback extension 1995421 PVC 5x2x0,25 660841

Dimensions and specifications may be changed without prior notice.

872
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for fixed laying
Base line for use on SEW drive systems

Technical data Cable structure Application


Temperature range Brake motor cable This high quality pre-assembled motor
flexing 0C to +60C Power supply cores connection cable is specially manufactured
fixed installation -20C to +80C Bare copper, extra fine wire conductor for applications with static installation.
Minimum bending radius acc. to DIN VDE 0295 cl.5 The special PVC outer sheath
flexing 20x cable high quality PP core insulation allows use in many industrial
fixed installation 9x cable Core identification 1, 2, 3 environments of general machine
Max. acceleration GN-YE conductor and plant construction.
2 m/s Brake cores
Bending cycles Copper conductors, bare Characteristic
50.000 for 20x cable High quality PP core insulation Economical alternatives to the cable
Operating voltage Core identification black, white carrier compatible cable types which
power supply cores 600/1000 V Shielding aluminium/polyester foil, otherwise meet all requirements of
Test voltage power cores 4 kV screened with tin-plated copper wires the servo drive manufacturers.
Insulation resistance 20 MOhm x km Motor cable These pre-assembled cables can be
Power supply cores produced in any lengths and also with
Approbations Bare copper, acc. to IEC 60228 cl.6 customer-specific modifications.
DESINA (ISO 23570) Core Insulation PVC
UL/CSA Core identification U/L1/C/L+ Note
V/L2 Please observe the drive or controller
W/L3/D/L- manufacturer's information about
GN-YE conductor maximum permitted cable length.
Complete shield of tin-plated copper The prefabricated cables listed here are not
braiding, coverage approx. 80% original parts, but accessories manufactured
PVC outer sheath by the company HELUKABEL GmbH.
Sheath colour orange (RAL 2003) The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel Helukabel Helukabel


Designation Part no. Designation Part no.
motor cable 1995502 PVC 4x1,5 660842 motor cable 13324853 PVC 4x1,5+2x1 660844
motor cable 05904552 PVC 4x2,5 660843 motor cable 13332139 PVC 4x2,5+2x1 660845

Dimensions and specifications may be changed without prior notice.

873
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled servo motor cables


for mobile use
Base line for use on SEW drive systems

Technical data Cable structure Application


Temperature range Brake motor cables This high quality pre-assembled
flexing 0C to +60C Power supply cores motor connection cable is specially
fixed installation -30C to +80C Copper conductors, bare manufactured for applications with
Minimum bending radius Polyolefin polymer core insulation high mechanical stress.
flexing 12x cable Core identification 1, 2, 3 The special PUR outer sheath
fixed installation 7x cable GN-YE conductor allows use in many industrial
Max. acceleration Brake cores environments of general machine
4 m/s Copper conductors, bare, fine wire stranded and plant construction.
Bending cycles Core insulation polyester
10 million for 12x cable Core identification black, white Characteristic
Operating voltage Shielding screened with tin-plated These pre-assembled cables can be
power supply cores 600/1000 V copper wires produced in any lengths and also with
Test voltage Motor cables customer-specific modifications.
power cores 3 kV Power supply cores
control cores 1,5 kV Copper conductors, bare, fine wire stranded Note
Insulation resistance 500 MOhm x km Core insulation polyester Please observe the installation instructions
Core identification U/L1/C/L+ for laying cables in cable carriers and
Approbations V/L2 the drive or controller manufacturer's
DESINA (ISO 23570) W/L3/D/L- information about maximum permitted
UL/CSA GN-YE conductor cable length.
Complete shield of tin-plated copper The prefabricated cables listed here are not
braiding, coverage approx. 80% original parts, but accessories manufactured
PUR outer sheath by the company HELUKABEL GmbH.
Sheath colour orange (RAL 2003) The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel Helukabel Helukabel


Designation Part no. Designation Part no.
motor cable 05906245 PUR 4x1,5 660846 motor cable 13331221 PUR 4x1,5+2x1 660848
motor cable 05906253 PUR 4x2,5 660847 motor cable 13332155 PUR 4x2,5+2x1 660849

Dimensions and specifications may be changed without prior notice.

874
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled feedback cables


For use on Heidenhain measurement systems

Technical data Cable structure Application


Temperature range Tinned copper conductor, fine wire stranded This pre-assembled sensor cable is suitable
-20C to +70C PVC/PP core insulation for use on Heidenhain measurement systems
Max. operating voltage 50 V Shielding (hand wheels).
Internal shield of tinned copper winding
External shield of tinned copper winding Characteristic
PUR outer sheath These pre-assembled cables can be
Sheath colour black produced in any lengths and also with
Structure/colour code customer-specific modifications.
((5x0,14)+4x0,25+2x0,25+1x0,5)
((WH, BN, GN, YE, GY) BU, BK, RD, Note
RD/BU, WH/BU, WH/GN, BN/GN, GY/PK)
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel
Designation Part no.
spiral cable 312879 PUR sw 660893

Dimensions and specifications may be changed without prior notice.

875
Pre-assembled Cables / Servo motor, feedback and fan cables

Pre-assembled adapter cables


For use on Heidenhain measurement systems (hand wheels)

Technical data Cable structure Application


Temperature range Tinned copper conductors This pre-assembled sensor cable is suitable
flexing -15C to +60C SR PVC core insulation for use on Heidenhain measurement systems
fixed installation -30C to +80C Complete shield of tin-plated (hand wheels).
Minimum bending radius copper braiding
flexing 15x cable PVC outer sheath Characteristic
fixed installation 8x cable Sheath colour black These pre-assembled cables can be
Max. operating voltage 300 V Structure/colour code produced in any lengths and also with
Test voltage 1,5 kV International code customer-specific modifications.
Insulation resistance 100 MOhm x km for UL/CSA cables
BK, BN, RD, OG, YE, GN Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.

Helukabel Helukabel
Designation Part no.
adapter cables 296466 PVC sw 660894

Dimensions and specifications may be changed without prior notice.

876
877
ROBOFLEX RECYCLE

Designation Properties Approvals Page

ROBOFLEX -recycle
M12 female one-end pre-assembled 3-pin, 4-pin, and 5-pin 880

ROBOFLEX-recycle M12 sensor cable 4-pin + PE one end preassembled 882

ROBOFLEX -recycle
M12 both ends pre-assembled 883

ROBOFLEX-recycle M12 5-pin + PE both ends pre-assembled 885

ROBOFLEX -recycle
M12 plug straight or angled one end preassembled 3-pin, 4-pin, and 5-pin 886

ROBOFLEX-recycle M8 female one end preassembled 887

ROBOFLEX -recycle
M8 both ends pre-assembled 888

ROBOFLEX -recycle
M8 plug straight or angled one end preassembled 3-pin and 4-pin 890

ROBOFLEX-recycle M12 sensor cable screened one end pre-assembled 891

ROBOFLEX -recycle
M12 sensor cable screened both ends pre-assembled 893

ROBOFLEX-recycle Twin cables M12 to M12 895

ROBOFLEX -recycle
Twin cables M12 to M12 896

879
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 femal one end pre-assembled 3-, 4- and 5-pin

Technical data Cable structure Properties


Approval: Bare copper litz wire, 42 x 0.10 mm very good resistance to oil as per
UL/cUL approved Core insulation polyester, black, blue, DIN VDE 0473-811-404/DIN EN 60811-404
Production brown good resistance to acids, alkalis and
in accordance with VDE standards Cores stranded in layers solvents
Temperature range: Sheath, special mix not cross-linked
fixed installation -40C to +105C weld splatter resistant, dull, low adhesion, weld splatter resistant
flexible -30C to +105C flame retardant and self-extinguishing recyclable
Nominal voltage: to DIN VDE 0482-332-1-2, halogen-free
300 V DIN EN 60332-1-2/ IEC 60332-1 Silicone and cadmium-free
Test voltage: Sheath colour: black Free of substances harmful to paint
2000 V Assembly (3-pin) adhesion Substances
Minimum bending radius: colour of cores brown, blue, black very high mechanical load capacity
7.5 x cable diameter (for flexible AD 4,9 +/-0,2 mm abrasion resistant
installation) Assembly (4-pin) wear-resistant
Traversing speed: colour of cores brown, blue, black, white Highly flexible
max. 3.3 m/s for 5 m of horizontal AD 5,2 +/-0,2 mm UV-resistant
traverse path length Assembly (5-pin) ROHS conformant
Acceleration: colour of cores brown, blue, black, white, grey CE conformant
max. 5 m/s AD 5,5 +/-0,2 mm
Flexing and torsion cycles: Note
min. 10 million. * Design for the standard 2 LEDs in the colours:
Torsional stress: yellow, green.
+/- 360/m 3 LEDs in the colours: white, yellow, green -
available upon request.
** Sensor cable ROBOFLEX-recycle M12
socket,
angled, preassembled on one side, 5 pins.
available on request.
IP67
A-coded
socket with LED
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
670742 ROBOFLEX-recycle 3 x 0,34 1,5 socket angled with 2 LED 14,7 -
670743 ROBOFLEX-recycle 3 x 0,34 3,0 socket angled with 2 LED 29,4 -
670744 ROBOFLEX-recycle 3 x 0,34 5,0 socket angled with 2 LED 49,0 -
670745 ROBOFLEX-recycle 3 x 0,34 10,0 socket angled with 2 LED 98,0 -
670746 ROBOFLEX-recycle 4 x 0,34 1,5 socket angled with 2 LED 19,7 -
670747 ROBOFLEX-recycle 4 x 0,34 3,0 socket angled with 2 LED 39,3 -
670748 ROBOFLEX-recycle 4 x 0,34 5,0 socket angled with 2 LED 65,5 -
670749 ROBOFLEX-recycle 4 x 0,34 10,0 socket angled with 2 LED 131,0 -
671543 ROBOFLEX-recycle 3 x 0,34 1,0 socket straight with 2 LED 9,8 -
671544 ROBOFLEX-recycle 3 x 0,34 1,5 socket straight with 2 LED 14,7 -
671546 ROBOFLEX-recycle 3 x 0,34 3,0 socket straight with 2 LED 29,4 -
671547 ROBOFLEX-recycle 3 x 0,34 5,0 socket straight with 2 LED 49,0 -
671548 ROBOFLEX-recycle 3 x 0,34 10,0 socket straight with 2 LED 98,0 -
671557 ROBOFLEX-recycle 4 x 0,34 1,0 socket straight with 2 LED 13,1 -
671550 ROBOFLEX-recycle 4 x 0,34 1,5 socket straight with 2 LED 19,7 -
671551 ROBOFLEX-recycle 4 x 0,34 3,0 socket straight with 2 LED 39,3 -
671552 ROBOFLEX-recycle 4 x 0,34 5,0 socket straight with 2 LED 65,5 -
671553 ROBOFLEX-recycle 4 x 0,34 10,0 socket straight with 2 LED 131,0 -
671473 ROBOFLEX-recycle 5 x 0,34 1,0 socket straight with 2 LED 16,5 -
671474 ROBOFLEX-recycle 5 x 0,34 1,5 socket straight with 2 LED 24,8 -
671476 ROBOFLEX-recycle 5 x 0,34 3,0 socket straight with 2 LED 49,5 -
671477 ROBOFLEX-recycle 5 x 0,34 5,0 socket straight with 2 LED 82,5 -
671478 ROBOFLEX-recycle 5 x 0,34 10,0 socket straight with 2 LED 165,0 -

Continuation

880
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 femal one end pre-assembled 3-, 4- and 5-pin


socket
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
670722 ROBOFLEX-recycle 3 x 0,34 1,5 socket angled 14,7 -
670723 ROBOFLEX-recycle 3 x 0,34 3,0 socket angled 29,4 -
670724 ROBOFLEX-recycle 3 x 0,34 5,0 socket angled 49,0 -
670725 ROBOFLEX-recycle 3 x 0,34 10,0 socket angled 98,0 -
670738 ROBOFLEX-recycle 4 x 0,34 1,5 socket angled 19,7 -
670739 ROBOFLEX-recycle 4 x 0,34 3,0 socket angled 39,3 -
670740 ROBOFLEX-recycle 4 x 0,34 5,0 socket angled 65,5 -
670741 ROBOFLEX-recycle 4 x 0,34 10,0 socket angled 131,0 -
671438 ROBOFLEX-recycle 5 x 0,34 1,5 socket angled 24,8 -
671439 ROBOFLEX-recycle 5 x 0,34 3,0 socket angled 49,5 -
671440 ROBOFLEX-recycle 5 x 0,34 5,0 socket angled 82,5 -
671441 ROBOFLEX-recycle 5 x 0,34 10,0 socket angled 165,0 -
670718 ROBOFLEX-recycle 3 x 0,34 1,5 socket straight 14,7 -
670719 ROBOFLEX-recycle 3 x 0,34 3,0 socket straight 29,4 -
670720 ROBOFLEX-recycle 3 x 0,34 5,0 socket straight 49,0 -
670721 ROBOFLEX-recycle 3 x 0,34 5,0 socket straight 49,0 -
670734 ROBOFLEX-recycle 4 x 0,34 1,5 socket straight 19,7 -
670735 ROBOFLEX-recycle 4 x 0,34 3,0 socket straight 39,3 -
670736 ROBOFLEX-recycle 4 x 0,34 5,0 socket straight 65,5 -
670737 ROBOFLEX-recycle 4 x 0,34 10,0 socket straight 131,0 -
671434 ROBOFLEX-recycle 5 x 0,34 1,5 socket straight 24,8 -
671435 ROBOFLEX-recycle 5 x 0,34 3,0 socket straight 49,5 -
671436 ROBOFLEX-recycle 5 x 0,34 5,0 socket straight 82,5 -
671437 ROBOFLEX-recycle 5 x 0,34 10,0 socket straight 165,0 -

Dimensions and specifications may be changed without prior notice.

881
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 sensor cable 4-pin + PE one end pre-assembled

Technical data Cable structure Properties


Approval: Bare copper litz wire, 42 x 0.10 mm very good resistance to oil as per
UL/cUL approved Core insulation polyester, black, blue, DIN VDE 0473-811-404/DIN EN 60811-404
Production brown good resistance to acids, alkalis and
in accordance with VDE standards Cores stranded in layers solvents
Temperature range: Sheath, special mix not cross-linked
fixed installation -40C to +105C weld splatter resistant, dull, low adhesion, weld splatter resistant
flexible -30C to +105C flame retardant and self-extinguishing recyclable
Nominal voltage: to DIN VDE 0482-332-1-2, halogen-free
300 V DIN EN 60332-1-2/ IEC 60332-1 Silicone and cadmium-free
Test voltage: Sheath colour: black Free of substances harmful to paint
2000 V Assembly (5-pin) adhesion Substances
Minimum bending radius: colour of cores brown, blue, black, white, very high mechanical load capacity
7.5 x cable diameter (for flexible installation) green/yellow abrasion resistant
Traversing speed: AD 5,5 +/-0,2 mm wear-resistant
max. 3.3 m/s for 5 m of horizontal Highly flexible
traverse path length UV-resistant
Acceleration: ROHS conformant
max. 5 m/s CE conformant
Flexing and torsion cycles:
min. 10 million. Note
Torsional stress: IP67
+/- 360/m A-coded
plug or socket one end pre-assembled
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
672393 ROBOFLEX-recycle 5 G 0,34 1,0 plug, straight 16,5 -
672394 ROBOFLEX-recycle 5 G 0,34 1,5 plug, straight 24,8 -
672396 ROBOFLEX-recycle 5 G 0,34 3,0 plug, straight 49,5 -
672397 ROBOFLEX-recycle 5 G 0,34 5,0 plug, straight 82,5 -
672399 ROBOFLEX-recycle 5 G 0,34 10,0 plug, straight 165,0 -
672403 ROBOFLEX-recycle 5 G 0,34 1,0 plug, angled 16,5 -
672404 ROBOFLEX-recycle 5 G 0,34 1,5 plug, angled 24,8 -
672406 ROBOFLEX-recycle 5 G 0,34 3,0 plug, angled 49,5 -
672407 ROBOFLEX-recycle 5 G 0,34 5,0 plug, angled 82,5 -
672409 ROBOFLEX-recycle 5 G 0,34 10,0 plug, angled 165,0 -
672343 ROBOFLEX-recycle 5 G 0,34 1,0 socket straight 16,5 -
672344 ROBOFLEX-recycle 5 G 0,34 1,5 socket straight 24,8 -
672346 ROBOFLEX-recycle 5 G 0,34 3,0 socket straight 49,5 -
672347 ROBOFLEX-recycle 5 G 0,34 5,0 socket straight 82,5 -
672349 ROBOFLEX-recycle 5 G 0,34 10,0 socket straight 165,0 -
672353 ROBOFLEX-recycle 5 G 0,34 1,0 socket angled 16,5 -
672354 ROBOFLEX-recycle 5 G 0,34 1,5 socket angled 24,8 -
672356 ROBOFLEX-recycle 5 G 0,34 3,0 socket angled 49,5 -
672357 ROBOFLEX-recycle 5 G 0,34 5,0 socket angled 82,5 -
672359 ROBOFLEX-recycle 5 G 0,34 10,0 socket angled 165,0 -

socket one end pre-assembled, 3 LED (gn, rd, ye)


Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
672413 ROBOFLEX-recycle 5 G 0,34 1,0 socket straight with 3 LED 16,5 -
672414 ROBOFLEX-recycle 5 G 0,34 1,5 socket straight with LED 24,8 -
672416 ROBOFLEX-recycle 5 G 0,34 3,0 socket straight with 3 LED 49,5 -
672417 ROBOFLEX-recycle 5 G 0,34 5,0 socket straight with 3 LED 82,5 -
672419 ROBOFLEX-recycle 5 G 0,34 10,0 socket straight with 3 LED 165,0 -
672363 ROBOFLEX-recycle 5 G 0,34 1,0 socket angled with 3 LED 16,5 -
672364 ROBOFLEX-recycle 5 G 0,34 1,5 socket angled with LED 24,8 -
672366 ROBOFLEX-recycle 5 G 0,34 3,0 socket angled with 3 LED 49,5 -
672367 ROBOFLEX-recycle 5 G 0,34 5,0 socket angled with 3 LED 82,5 -
672369 ROBOFLEX-recycle 5 G 0,34 10,0 socket angled with 3 LED 165,0 -

Dimensions and specifications may be changed without prior notice.

882
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 both ends pre-assembled

Technical data Cable structure Properties


Approval: Bare copper litz wire, 42 x 0.10 mm very good resistance to oil as per
UL/cUL approved Core insulation polyester, black, blue, DIN VDE 0473-811-404/DIN EN 60811-404
Production brown good resistance to acids, alkalis and
in accordance with VDE standards Cores stranded in layers solvents
Temperature range: Sheath, special mix not cross-linked
fixed installation -40C to +105C weld splatter resistant, dull, low adhesion, weld splatter resistant
flexible -30C to +105C flame retardant and self-extinguishing recyclable
Nominal voltage: to DIN VDE 0482-332-1-2, halogen-free
300 V IN EN 60332-1-2/ IEC 60332-1 Silicone and cadmium-free
Test voltage: Sheath colour: black Free of substances harmful to paint
2000 V Assembly (3-pin) adhesion Substances
Minimum bending radius: colour in cores brown, blue, black very high mechanical load capacity
7.5 x cable diameter (for flexible AD 4,9 +/-0,2 mm abrasion resistant
installation) Assembly (4-pin) wear-resistant
Traversing speed: colour of cores brown, blue, black, white Highly flexible
max. 3.3 m/s for 5 m of horizontal AD 5,2 +/-0,2 mm UV-resistant
traverse path length Assembly (5-pin) ROHS conformant
Acceleration: colour of cores brown, blue, black, white, grey CE conformant
max. 5 m/s AD 5,5 +/-0,2 mm
Flexing and torsion cycles: Note
min. 10 million. *Design for the standard 2 LEDs in the colours:
Torsional stress: yellow, green.
+/- 360/m 3 LEDs in the colours: white, yellow ,green -
available upon request.
** Sensor cable ROBOFLEX-recycle M12 plug,
straight and socket, angled, pre-assembled on
both side, 5-pin. available on request.
IP67
A-coded
plug straight / socket angled with LED
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
670866 ROBOFLEX-recycle 3 x 0,34 1,0 plug straight / socket, angled with 2 LED 9,8 -
670802 ROBOFLEX-recycle 3 x 0,34 1,5 plug straight / socket, angled with 2 LED 14,7 -
670803 ROBOFLEX-recycle 3 x 0,34 3,0 plug straight / socket, angled with 2 LED 29,4 -
670804 ROBOFLEX-recycle 3 x 0,34 5,0 plug straight / socket, angled with 2 LED 49,0 -
670805 ROBOFLEX-recycle 3 x 0,34 10,0 plug straight / socket, angled with 2 LED 98,0 -
670867 ROBOFLEX-recycle 4 x 0,34 1,0 plug straight / socket, angled with 2 LED 13,1 -
670814 ROBOFLEX-recycle 4 x 0,34 1,5 plug straight / socket, angled with 2 LED 19,7 -
670815 ROBOFLEX-recycle 4 x 0,34 3,0 plug straight / socket, angled with 2 LED 39,3 -
670816 ROBOFLEX-recycle 4 x 0,34 5,0 plug straight / socket, angled with 2 LED 65,5 -
670817 ROBOFLEX-recycle 4 x 0,34 10,0 plug straight / socket, angled with 2 LED 131,0 -

plug straight / socket straight


Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
671341 ROBOFLEX-recycle 3 x 0,34 1,0 plug straight / socket straight 9,8 -
670750 ROBOFLEX-recycle 3 x 0,34 1,5 plug straight / socket straight 14,7 -
670751 ROBOFLEX-recycle 3 x 0,34 3,0 plug straight / socket straight 29,4 -
670752 ROBOFLEX-recycle 3 x 0,34 5,0 plug straight / socket straight 49,0 -
670753 ROBOFLEX-recycle 3 x 0,34 10,0 plug straight / socket straight 98,0 -
670771 ROBOFLEX-recycle 4 x 0,34 1,0 plug straight / socket straight 13,1 -
670774 ROBOFLEX-recycle 4 x 0,34 1,5 plug straight / socket straight 19,7 -
670775 ROBOFLEX-recycle 4 x 0,34 3,0 plug straight / socket straight 39,3 -
670776 ROBOFLEX-recycle 4 x 0,34 5,0 plug straight / socket straight 65,5 -
670777 ROBOFLEX-recycle 4 x 0,34 10,0 plug straight / socket straight 131,0 -
671493
671494
ROBOFLEX-recycle
ROBOFLEX-recycle
5 x 0,34 1,0
5 x 0,34 1,5
plug straight / socket straight
plug straight / socket straight
16,5
24,8
-
- U
671496 ROBOFLEX-recycle 5 x 0,34 3,0 plug straight / socket straight 49,5 -
671497 ROBOFLEX-recycle 5 x 0,34 5,0 plug straight / socket straight 82,5 -
671499 ROBOFLEX-recycle 5 x 0,34 10,0 plug straight / socket straight 165,0 -

Continuation

883
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 both ends pre-assembled


plug straight / socket angled
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
670757 ROBOFLEX-recycle 3 x 0,34 1,0 plug straight / socket angled 9,8 -
670758 ROBOFLEX-recycle 3 x 0,34 1,5 plug straight / socket angled 14,7 -
670759 ROBOFLEX-recycle 3 x 0,34 3,0 plug straight / socket angled 29,4 -
670760 ROBOFLEX-recycle 3 x 0,34 5,0 plug straight / socket angled 49,0 -
670761 ROBOFLEX-recycle 3 x 0,34 10,0 plug straight / socket angled 98,0 -
670781 ROBOFLEX-recycle 4 x 0,34 1,0 plug straight / socket angled 13,1 -
670782 ROBOFLEX-recycle 4 x 0,34 1,5 plug straight / socket angled 19,7 -
670783 ROBOFLEX-recycle 4 x 0,34 3,0 plug straight / socket angled 39,3 -
670784 ROBOFLEX-recycle 4 x 0,34 5,0 plug straight / socket angled 65,5 -
670785 ROBOFLEX-recycle 4 x 0,34 10,0 plug straight / socket angled 131,0 -
671483 ROBOFLEX-recycle 5 x 0,34 1,0 plug straight / socket angled 16,5 -
671484 ROBOFLEX-recycle 5 x 0,34 1,5 plug straight / socket angled 24,8 -
671486 ROBOFLEX-recycle 5 x 0,34 3,0 plug straight / socket angled 49,5 -
671487 ROBOFLEX-recycle 5 x 0,34 5,0 plug straight / socket angled 82,5 -
671489 ROBOFLEX-recycle 5 x 0,34 10,0 plug straight / socket angled 165,0 -

plug angled/ socket angled


Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
670766 ROBOFLEX-recycle 3 x 0,34 1,5 plug angled / socket angled 14,7 -
670767 ROBOFLEX-recycle 3 x 0,34 3,0 plug angled / socket angled 29,4 -
670768 ROBOFLEX-recycle 3 x 0,34 5,0 plug angled / socket angled 49,0 -
670769 ROBOFLEX-recycle 3 x 0,34 10,0 plug angled / socket angled 98,0 -
670790 ROBOFLEX-recycle 4 x 0,34 1,5 plug angled / socket angled 19,7 -
670791 ROBOFLEX-recycle 4 x 0,34 3,0 plug angled / socket angled 39,3 -
670792 ROBOFLEX-recycle 4 x 0,34 5,0 plug angled / socket angled 65,5 -
670793 ROBOFLEX-recycle 4 x 0,34 10,0 plug angled / socket angled 131,0 -
671533 ROBOFLEX-recycle 5 x 0,34 1,5 plug angled / socket angled 24,8 -
671534 ROBOFLEX-recycle 5 x 0,34 3,0 plug angled / socket angled 49,5 -
671536 ROBOFLEX-recycle 5 x 0,34 5,0 plug angled / socket angled 82,5 -
671537 ROBOFLEX-recycle 5 x 0,34 10,0 plug angled / socket angled 165,0 -

Dimensions and specifications may be changed without prior notice.

884
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 4-pin + PE both ends pre-assembled

Technical data Cable structure Properties


Approval: Bare copper litz wire, 42 x 0.10 mm very good resistance to oil as per
UL/cUL approved Core insulation polyester, black, blue, DIN VDE 0473-811-404/DIN EN 60811-404
Production brown good resistance to acids, alkalis and
in accordance with VDE standards Cores stranded in layers solvents
Temperature range: Sheath, special mix not cross-linked
fixed installation -40C to +105C weld splatter resistant, dull, low adhesion, weld splatter resistant
flexible -30C to +105C flame retardant and self-extinguishing recyclable
Nominal voltage: to DIN VDE 0482-332-1-2, halogen-free
300 V DIN EN 60332-1-2/ IEC 60332-1 Silicone and cadmium-free
Test voltage: Sheath colour: black Free of substances harmful to paint
2000 V Assembly (5-pin) adhesion Substances
Minimum bending radius: colour of cores brown, blue, black, white, very high mechanical load capacity
7.5 x cable diameter (for flexible green/yellow abrasion resistant
installation) AD 5,5 +/-0,2 mm wear-resistant
Traversing speed: Highly flexible
max. 3.3 m/s for 5 m of horizontal UV-resistant
traverse path length ROHS conformant
Acceleration: CE conformant
max. 5 m/s
Flexing and torsion cycles: Note
min. 10 million. IP67
Torsional stress: A-codiert
+/- 360/m
both ends pre-assembled
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
672303 ROBOFLEX-recycle 5 G 0,34 1,0 plug straight / socket straight 16,5 -
672304 ROBOFLEX-recycle 5 G 0,34 1,5 plug straight / socket straight 24,8 -
672306 ROBOFLEX-recycle 5 G 0,34 3,0 plug straight / socket straight 49,5 -
672307 ROBOFLEX-recycle 5 G 0,34 5,0 plug straight / socket straight 82,5 -
672309 ROBOFLEX-recycle 5 G 0,34 10,0 plug straight / socket straight 165,0 -
672443 ROBOFLEX-recycle 5 G 0,34 1,0 plug angled / socket angled 16,5 -
672444 ROBOFLEX-recycle 5 G 0,34 1,5 plug angled / socket angled 24,8 -
672446 ROBOFLEX-recycle 5 G 0,34 3,0 plug angled / socket angled 49,5 -
672447 ROBOFLEX-recycle 5 G 0,34 5,0 plug angled / socket angled 82,5 -
672449 ROBOFLEX-recycle 5 G 0,34 10,0 plug angled / socket angled 165,0 -
672313 ROBOFLEX-recycle 5 G 0,34 1,0 plug straight / socket angled 16,5 -
672314 ROBOFLEX-recycle 5 G 0,34 1,5 plug straight / socket angled 24,8 -
672316 ROBOFLEX-recycle 5 G 0,34 3,0 plug straight / socket angled 49,5 -
672317 ROBOFLEX-recycle 5 G 0,34 5,0 plug straight / socket angled 82,5 -
672319 ROBOFLEX-recycle 5 G 0,34 10,0 plug straight / socket angled 165,0 -

both ends pre-assembled, 3 LED (gn, rd, ye)


Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
672333 ROBOFLEX-recycle 5 G 0,34 1,0 plug straight / socket straight with 3 LED 16,5 -
672334 ROBOFLEX-recycle 5 G 0,34 1,5 plug straight / socket straight with 3 LED 24,8 -
672336 ROBOFLEX-recycle 5 G 0,34 3,0 plug straight / socket straight with 3 LED 49,5 -
672337 ROBOFLEX-recycle 5 G 0,34 5,0 plug straight / socket straight with 3 LED 82,5 -
672339 ROBOFLEX-recycle 5 G 0,34 10,0 plug straight / socket straight with 3 LED 165,0 -
672373 ROBOFLEX-recycle 5 G 0,34 1,0 plug angled / socket angled with 3 LED 16,5 -
672374 ROBOFLEX-recycle 5 G 0,34 1,5 plug angled / socket angled with 3 LED 24,8 -
672376 ROBOFLEX-recycle 5 G 0,34 3,0 plug angled / socket angled with 3 LED 49,5 -
672377 ROBOFLEX-recycle 5 G 0,34 5,0 plug angled / socket angled with 3 LED 82,5 -
672379 ROBOFLEX-recycle 5 G 0,34 10,0 plug angled / socket angled with 3 LED 165,0 -
672323 ROBOFLEX-recycle 5 G 0,34 1,0 plug straight / socket angled with 3 LED 16,5 -
672324 ROBOFLEX-recycle 5 G 0,34 1,5 plug straight / socket angled with 3 LED 24,8 -
672326 ROBOFLEX-recycle 5 G 0,34 3,0 plug straight / socket angled with 3 LED 49,5 -
672327
672329
ROBOFLEX-recycle
ROBOFLEX-recycle
5 G 0,34 5,0
5 G 0,34 10,0
plug straight / socket angled with 3 LED
plug straight / socket angled with 3 LED
82,5
165,0
-
- U
Dimensions and specifications may be changed without prior notice.

885
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 plug straight or angled, pre-assembled on one end, 3-pin,


4-pin and 5-pin

Technical data Cable structure Properties


Approval: Bare copper litz wire, 42 x 0.10 mm very good resistance to oil to
UL/cUL approved Core insulation polyester, black, blue, DIN VDE 0473-811-404/DIN EN 60811-404
Production brown good resistance to acids, alkalis and
in accordance with VDE standards Cores stranded in layers solvents
Temperature range: Sheath, special mix not cross-linked
fixed installation -40C to +105C weld splatter resistant, dull, low adhesion, weld splatter resistant
flexible -30C to +105C flame retardant and self-extinguishing recyclable
Nominal voltage: to DIN VDE 0482-332-1-2, halogen-free
300 V DIN EN 60332-1-2/ IEC 60332-1 Silicone and cadmium-free
Test voltage: Sheath colour: black Free of substances harmful to paint
2000 V Assembly (3-pin) adhesion Substances
Minimum bending radius: colour of cores brown, blue, black very high mechanical load capacity
7.5 x cable diameter (for flexible AD 4,9 +/-0,2mm abrasion resistant
installation) Assembly (4-pin) wear-resistant
Traversing speed: colour of cores brown, blue, black, white Highly flexible
max. 3.3 m/s for 5 m of horizontal AD 5,2 +/-0,2mm UV-resistant
traverse path length Assembly (5-pin) ROHS conformant
Acceleration: colour of cores brown, blue, black, white, grey CE conformant
max. 5 m/s AD 5,5 +/-0,2mm
Flexing and torsion cycles: Note
min. 10 million. IP67
Torsional stress: A-coded
+/- 360/m

Part no. Cable type / Length Plug type Cop.


cross-sec. m weight
mm kg / 1000 pcs.
670710 ROBOFLEX-recycle 3 x 0,34 1,5 plug, straight 14,7 -
670711 ROBOFLEX-recycle 3 x 0,34 3,0 plug, straight 29,4 -
670712 ROBOFLEX-recycle 3 x 0,34 5,0 plug, straight 49,0 -
670713 ROBOFLEX-recycle 3 x 0,34 10,0 plug, straight 98,0 -
670714 ROBOFLEX-recycle 3 x 0,34 1,5 plug, angled 14,7 -
670715 ROBOFLEX-recycle 3 x 0,34 3,0 plug, angled 29,4 -
670716 ROBOFLEX-recycle 3 x 0,34 5,0 plug, angled 49,0 -
670717 ROBOFLEX-recycle 3 x 0,34 10,0 plug, angled 98,0 -
670726 ROBOFLEX-recycle 4 x 0,34 1,5 plug, straight 19,7 -
670727 ROBOFLEX-recycle 4 x 0,34 3,0 plug, straight 39,3 -
670728 ROBOFLEX-recycle 4 x 0,34 5,0 plug, straight 65,5 -
670729 ROBOFLEX-recycle 4 x 0,34 10,0 plug, straight 131,0 -
670730 ROBOFLEX-recycle 4 x 0,34 1,5 plug, angled 19,7 -
670731 ROBOFLEX-recycle 4 x 0,34 3,0 plug, angled 39,3 -
670732 ROBOFLEX-recycle 4 x 0,34 5,0 plug, angled 65,5 -
670733 ROBOFLEX-recycle 4 x 0,34 10,0 plug, angled 131,0 -
671426 ROBOFLEX-recycle 5 x 0,34 1,5 plug, straight 24,8 -
671427 ROBOFLEX-recycle 5 x 0,34 3,0 plug, straight 49,5 -
671428 ROBOFLEX-recycle 5 x 0,34 5,0 plug, straight 82,5 -
671429 ROBOFLEX-recycle 5 x 0,34 10,0 plug, straight 165,0 -
671430 ROBOFLEX-recycle 5 x 0,34 1,5 plug, angled 24,8 -
671431 ROBOFLEX-recycle 5 x 0,34 3,0 plug, angled 49,5 -
671432 ROBOFLEX-recycle 5 x 0,34 5,0 plug, angled 82,5 -
671433 ROBOFLEX-recycle 5 x 0,34 10,0 plug, angled 165,0 -

Dimensions and specifications may be changed without prior notice.

886
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M8 femal one end pre-assembled

Technical data Cable structure Properties


Approval: Bare copper litz wire, 42 x 0.10 mm very good resistance to oil to
UL/cUL approved Core insulation polyester, black, blue, DIN VDE 0473-811-404/DIN EN 60811-404
Production brown good resistance to acids, alkalis and
in accordance with VDE standards Cores stranded in layers solvents
Temperature range: Sheath, special mix not cross-linked
fixed installation -40C to +105C weld splatter resistant, dull, low adhesion, weld splatter resistant
flexible -30C to +105C flame retardant and self-extinguishing recyclable
Nominal voltage: to DIN VDE 0482-332-1-2, halogen-free
300 V DIN EN 60332-1-2/ IEC 60332-1 Silicone and cadmium-free
Test voltage: Sheath colour: black Free of substances harmful to paint
2000 V Assembly (3-pin) adhesion Substances
Minimum bending radius: colour of cores brown, blue, black very high mechanical load capacity
7.5 x cable diameter (for flexible AD 4,9 +/-0,2 mm abrasion resistant
installation) Assembly (4-pin) wear-resistant
Traversing speed: colour of cores brown. blue, black, white Highly flexible
max. 3.3 m/s for 5 m of horizontal AD 5,2 +/-0,2 mm UV-resistant
traverse path length ROHS conformant
Acceleration: CE conformant
max. 5 m/s
Flexing and torsion cycles: Note
min. 10 million. IP67
Torsional stress: A-coded
+/- 360/m
socket angled with 2 LED
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
670672 ROBOFLEX-recycle 3 x 0,34 1,5 socket angled with 2 LED 14,7 -
670673 ROBOFLEX-recycle 3 x 0,34 3,0 socket angled with 2 LED 29,4 -
670674 ROBOFLEX-recycle 3 x 0,34 5,0 socket angled with 2 LED 49,0 -
670675 ROBOFLEX-recycle 3 x 0,34 10,0 socket angled with 2 LED 98,0 -
670688 ROBOFLEX-recycle 4 x 0,34 1,5 socket angled with 2 LED 19,7 -
670689 ROBOFLEX-recycle 4 x 0,34 3,0 socket angled with 2 LED 39,3 -
670690 ROBOFLEX-recycle 4 x 0,34 5,0 socket angled with 2 LED 65,5 -
670691 ROBOFLEX-recycle 4 x 0,34 10,0 socket angled with 2 LED 131,0 -

plug straight
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
670668 ROBOFLEX-recycle 3 x 0,34 1,5 socket straight 14,7 -
670669 ROBOFLEX-recycle 3 x 0,34 3,0 socket straight 29,4 -
670670 ROBOFLEX-recycle 3 x 0,34 5,0 socket straight 49,0 -
670671 ROBOFLEX-recycle 3 x 0,34 10,0 socket straight 98,0 -
670656 ROBOFLEX-recycle 3 x 0,34 1,5 socket angled 14,7 -
670657 ROBOFLEX-recycle 3 x 0,34 3,0 socket angled 29,4 -
670658 ROBOFLEX-recycle 3 x 0,34 5,0 socket angled 49,0 -
670659 ROBOFLEX-recycle 3 x 0,34 10,0 socket angled 98,0 -
670684 ROBOFLEX-recycle 4 x 0,34 1,5 socket straight 19,7 -
670685 ROBOFLEX-recycle 4 x 0,34 3,0 socket straight 39,3 -
670686 ROBOFLEX-recycle 4 x 0,34 5,0 socket straight 65,5 -
670687 ROBOFLEX-recycle 4 x 0,34 10,0 socket straight 131,0 -
670693 ROBOFLEX-recycle 4 x 0,34 1,5 socket angled 19,7 -
670694 ROBOFLEX-recycle 4 x 0,34 3,0 socket angled 39,3 -
670695 ROBOFLEX-recycle 4 x 0,34 5,0 socket angled 65,5 -
670696 ROBOFLEX-recycle 4 x 0,34 10,0 socket angled 131,0 -

Dimensions and specifications may be changed without prior notice.

887
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M8 pre-assembled on both ends

Technical data Cable structure Properties


Approval: Bare copper litz wire, 42 x 0.10 mm very good resistance to oil
UL/cUL approved Cores stranded in layers to DIN VDE 0473-811-404/
Production Sheath, special mix DIN EN 60811-404
in accordance with VDE standards weld splatter resistant, dull, low adhesion, good resistance to acids, alkalis and
Temperature range: flame retardant and self-extinguishing solvents
fixed installation -40C to +105C to DIN VDE 0482-332-1-2, not cross-linked
flexible -30C to +105C DIN EN 60332-1-2/IEC 60332-1 weld splatter resistant
Nominal voltage: Sheath colour: black recyclable
300 V Assembly (3-pin) halogen-free
Test voltage: colour of cores brown, blue, black Silicone and cadmium-free
2000 V AD 4,9 +/-0,2mm Free of substances harmful to paint
Minimum bending radius: Assembly (4-pin) adhesion Substances
7.5 x cable diameter (for colour of cores brown, blue, black, white very high mechanical load capacity
flexible installation) AD 5,2 +/-0,2mm abrasion resistant
Traversing speed: wear-resistant
max. 3.3 m/s for 5 m of horizontal Highly flexible
traverse path length UV-resistant
Acceleration: ROHS conformant
max. 5 m/s CE conformant
Flexing and torsion cycles:
min. 10 million. Note
Torsional stress: * Design for the standard 2 LEDs in the colours:
+/- 360/m yellow, green.
IP67
A-coded
plug straight / socket angled with 2 LED
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
670849 ROBOFLEX-recycle 3 x 0,34 1,0 plug straight / socket, angled with 2 LED 9,8 -
670850 ROBOFLEX-recycle 3 x 0,34 1,5 plug straight / socket, angled with 2 LED 14,7 -
670851 ROBOFLEX-recycle 3 x 0,34 3,0 plug straight / socket, angled with 2 LED 29,4 -
670852 ROBOFLEX-recycle 3 x 0,34 5,0 plug straight / socket, angled with 2 LED 49,0 -
670853 ROBOFLEX-recycle 3 x 0,34 10,0 plug straight / socket, angled with 2 LED 98,0 -
670861 ROBOFLEX-recycle 4 x 0,34 1,0 plug straight / socket, angled with 2 LED 13,1 -
670862 ROBOFLEX-recycle 4 x 0,34 1,5 plug straight / socket, angled with 2 LED 19,7 -
670863 ROBOFLEX-recycle 4 x 0,34 3,0 plug straight / socket, angled with 2 LED 39,3 -
670864 ROBOFLEX-recycle 4 x 0,34 5,0 plug straight / socket, angled with 2 LED 65,5 -
670865 ROBOFLEX-recycle 4 x 0,34 10,0 plug straight / socket, angled with 2 LED 131,0 -

plug straight / socket straight


Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
671356 ROBOFLEX-recycle 3 x 0,34 1,0 plug straight / socket straight 9,8 -
670822 ROBOFLEX-recycle 3 x 0,34 1,5 plug straight / socket straight 14,7 -
670823 ROBOFLEX-recycle 3 x 0,34 3,0 plug straight / socket straight 29,4 -
670824 ROBOFLEX-recycle 3 x 0,34 5,0 plug straight / socket straight 49,0 -
670825 ROBOFLEX-recycle 3 x 0,34 10,0 plug straight / socket straight 98,0 -
671351 ROBOFLEX-recycle 4 x 0,34 1,0 plug straight / socket straight 13,1 -
670834 ROBOFLEX-recycle 4 x 0,34 1,5 plug straight / socket straight 19,7 -
670835 ROBOFLEX-recycle 4 x 0,34 3,0 plug straight / socket straight 39,3 -
670836 ROBOFLEX-recycle 4 x 0,34 5,0 plug straight / socket straight 65,5 -
670837 ROBOFLEX-recycle 4 x 0,34 10,0 plug straight / socket straight 131,0 -

Continuation

888
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M8 pre-assembled on both ends


plug straight / socket angled
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
671332 ROBOFLEX-recycle 3 x 0,34 1,0 plug straight / socket angled 9,8 -
670826 ROBOFLEX-recycle 3 x 0,34 1,5 plug straight / socket angled 14,7 -
670827 ROBOFLEX-recycle 3 x 0,34 3,0 plug straight / socket angled 29,4 -
670828 ROBOFLEX-recycle 3 x 0,34 5,0 plug straight / socket angled 49,0 -
670829 ROBOFLEX-recycle 3 x 0,34 10,0 plug straight / socket angled 98,0 -
671333 ROBOFLEX-recycle 4 x 0,34 1,0 plug straight / socket angled 13,1 -
670838 ROBOFLEX-recycle 4 x 0,34 1,5 plug straight / socket angled 19,7 -
670839 ROBOFLEX-recycle 4 x 0,34 3,0 plug straight / socket angled 39,3 -
670840 ROBOFLEX-recycle 4 x 0,34 5,0 plug straight / socket angled 65,5 -
670841 ROBOFLEX-recycle 4 x 0,34 10,0 plug straight / socket angled 131,0 -

plug angled / socket angled


Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
671334 ROBOFLEX-recycle 3 x 0,34 1,0 plug angled / socket angled 9,8 -
670830 ROBOFLEX-recycle 3 x 0,34 1,5 plug angled / socket angled 14,7 -
670831 ROBOFLEX-recycle 3 x 0,34 3,0 plug angled / socket angled 29,4 -
670832 ROBOFLEX-recycle 3 x 0,34 5,0 plug angled / socket angled 49,0 -
670833 ROBOFLEX-recycle 3 x 0,34 10,0 plug angled / socket angled 98,0 -
671335 ROBOFLEX-recycle 4 x 0,34 1,0 plug angled / socket angled 13,1 -
670842 ROBOFLEX-recycle 4 x 0,34 1,5 plug angled / socket angled 19,7 -
670843 ROBOFLEX-recycle 4 x 0,34 3,0 plug angled / socket angled 39,3 -
670844 ROBOFLEX-recycle 4 x 0,34 5,0 plug angled / socket angled 65,5 -
670845 ROBOFLEX-recycle 4 x 0,34 10,0 plug angled / socket angled 131,0 -

Dimensions and specifications may be changed without prior notice.

889
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M8 plug, straight or angled, pre-assembled on one side, 3-pin


and 4-pin

Technical data Cable structure Properties


Approval: Bare copper litz wire, 42 x 0.10 mm very good resistance to oil as per
UL/cUL approved Core insulation polyester, black, blue, DIN VDE 0473-811-404/DIN EN 60811-404
Production brown good resistance to acids, alkalis and
in accordance with VDE standards Cores stranded in layers solvents
Temperature range: Sheath, special mix not cross-linked
fixed installation -40C to +105C weld splatter resistant, dull, low adhesion, weld splatter resistant
flexible -30C to +105C flame retardant and self-extinguishing recyclable
Nominal voltage: to DIN VDE 0482-332-1-2, halogen-free
300 V DIN EN 60332-1-2/ IEC 60332-1 Silicone and cadmium-free
Test voltage: Sheath colour: black Free of substances harmful to paint
2000 V Assembly (3-pin) adhesion Substances
Minimum bending radius: colour of cores brown, blue, black very high mechanical load capacity
7.5 x cable diameter (for flexible installation) AD 4,9 +/-0,2 mm abrasion resistant
Traversing speed: Assembly (4-pin) wear-resistant
max. 3.3 m/s for 5 m of horizontal traverse colour of cores brown, blue, black, white Highly flexible
path length AD 5,2 +/-0,2 mm UV-resistant
Acceleration: ROHS conformant
max. 5 m/s CE conformant
Flexing and torsion cycles:
min. 10 million. Note
Torsional stress: IP67
+/- 360/m A-coded

Part no. Cable type / Length Plug type Cop.


cross-sec. m weight
mm kg / 1000 pcs.
670660 ROBOFLEX-recycle 3 x 0,34 1,5 plug, straight 14,7 -
670661 ROBOFLEX-recycle 3 x 0,34 3,0 plug, straight 29,4 -
670662 ROBOFLEX-recycle 3 x 0,34 5,0 plug, straight 49,0 -
670663 ROBOFLEX-recycle 3 x 0,34 10,0 plug, straight 98,0 -
670664 ROBOFLEX-recycle 3 x 0,34 1,5 plug, angled 14,7 -
670665 ROBOFLEX-recycle 3 x 0,34 3,0 plug, angled 29,4 -
670666 ROBOFLEX-recycle 3 x 0,34 5,0 plug, angled 29,4 -
670667 ROBOFLEX-recycle 3 x 0,34 10,0 plug, angled 98,0 -
670676 ROBOFLEX-recycle 4 x 0,34 1,5 plug, straight 19,7 -
670677 ROBOFLEX-recycle 4 x 0,34 3,0 plug, straight 39,3 -
670678 ROBOFLEX-recycle 4 x 0,34 5,0 plug, straight 65,5 -
670679 ROBOFLEX-recycle 4 x 0,34 10,0 plug, straight 131,0 -
670680 ROBOFLEX-recycle 4 x 0,34 1,5 plug, angled 19,7 -
670681 ROBOFLEX-recycle 4 x 0,34 3,0 plug, angled 39,3 -
670682 ROBOFLEX-recycle 4 x 0,34 5,0 plug, angled 65,5 -
670683 ROBOFLEX-recycle 4 x 0,34 10,0 plug, angled 131,0 -

Dimensions and specifications may be changed without prior notice.

890
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 sensor cable screened one end pre-assembled

Technical data Cable structure Properties


Approval: Bare copper stranded wire, 42 x 0.10 mm very good resistance to oil as per
UL/cUL approved Cores stranded in layers DIN VDE 0473-811-404/DIN EN 60811-404
Production Polyester foil taping good resistance to acids, alkalis and
in accordance with VDE standards Screening of tinned copper braid, solvents
Temperature range: coverage approx. 85%, D-screen for Robot not cross-linked
fixed installation -40C to +105C applications weld splatter resistant
flexible -30C to +105C Special compound sheath, weld-splatter recyclable
Nominal voltage: resistant, recyclable, matt, low-adhesion, halogen-free
300 V flame retardant and self-extinguishing Silicone and cadmium-free
Test voltage: to DIN VDE 0482-332-1-2, Free of substances harmful to paint
2000 V DIN EN 60332-1-2/ IEC 60332-1 adhesion Substances
Minimum bending radius: Sheath colour: black very high mechanical load capacity
7.5 x cable diameter (for flexible Assembly (3-pin) abrasion resistant
installation) Core insulation polyester, black, brown, blue, wear-resistant
Traversing speed: black Highly flexible
max. 3.3 m/s for 5 m of horizontal Outer diameter 5,2 +/-0.2 mm UV-resistant
traverse path length Assembly (4-pin) ROHS conformant
Acceleration: Core insulation polyester, brown, blue, black, CE conformant
max. 5 m/s white
Flexing and torsion cycles: Outer diameter 5.5 +/-0.2 mm Note
min. 10 million. Assembly (5-pin) IP67
Torsional stress: Core insulation polyester, brown, blue, black, A-coded
+/- 360/m white, green
Outer diameter 6,0+/-0.2 mm
plug straight pre-assembled
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
671893 ROBOFLEX-recycle 3 x 0,34 1,0 plug, straight 19,6 -
671894 ROBOFLEX-recycle 3 x 0,34 1,5 plug, straight 29,4 -
671896 ROBOFLEX-recycle 3 x 0,34 3,0 plug, straight 58,8 -
671897 ROBOFLEX-recycle 3 x 0,34 5,0 plug, straight 98,0 -
671899 ROBOFLEX-recycle 3 x 0,34 10,0 plug, straight 196,0 -
671903 ROBOFLEX-recycle 3 x 0,34 1,0 plug, angled 19,6 -
671904 ROBOFLEX-recycle 3 x 0,34 1,5 plug, angled 29,4 -
671906 ROBOFLEX-recycle 3 x 0,34 3,0 plug, angled 58,8 -
671907 ROBOFLEX-recycle 3 x 0,34 5,0 plug, angled 98,0 -
671909 ROBOFLEX-recycle 3 x 0,34 10,0 plug, angled 196,0 -
671913 ROBOFLEX-recycle 4 x 0,34 1,0 plug, straight 24,2 -
671914 ROBOFLEX-recycle 4 x 0,34 1,5 plug, straight 36,3 -
671916 ROBOFLEX-recycle 4 x 0,34 3,0 plug, straight 72,6 -
671917 ROBOFLEX-recycle 4 x 0,34 5,0 plug, straight 121,0 -
671919 ROBOFLEX-recycle 4 x 0,34 10,0 plug, straight 242,0 -
671923 ROBOFLEX-recycle 4 x 0,34 1,0 plug, angled 24,2 -
671924 ROBOFLEX-recycle 4 x 0,34 1,5 plug, angled 36,3 -
671926 ROBOFLEX-recycle 4 x 0,34 3,0 plug, angled 72,6 -
671927 ROBOFLEX-recycle 4 x 0,34 5,0 plug, angled 121,0 -
671929 ROBOFLEX-recycle 4 x 0,34 10,0 plug, angled 242,0 -
671933 ROBOFLEX-recycle 5 x 0,34 1,0 plug, straight 30,0 -
671934 ROBOFLEX-recycle 5 x 0,34 1,5 plug, straight 45,0 -
671936 ROBOFLEX-recycle 5 x 0,34 3,0 plug, straight 90,0 -
671937 ROBOFLEX-recycle 5 x 0,34 5,0 plug, straight 150,0 -
671939 ROBOFLEX-recycle 5 x 0,34 10,0 plug, straight 300,0 -
671943 ROBOFLEX-recycle 5 x 0,34 1,0 plug, angled 30,0 -
671944 ROBOFLEX-recycle 5 x 0,34 1,5 plug, angled 45,0 -
671946 ROBOFLEX-recycle 5 x 0,34 3,0 plug, angled 90,0 -
671947 ROBOFLEX-recycle 5 x 0,34 5,0 plug, angled 150,0 -
671949 ROBOFLEX-recycle 5 x 0,34 10,0 plug, angled 300,0 -

Continuation

891
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 sensor cable screened one end pre-assembled


socket one end pre-assembled
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
671873 ROBOFLEX-recycle 3 x 0,34 1,0 socket straight 19,6 -
671874 ROBOFLEX-recycle 3 x 0,34 1,5 socket straight 29,4 -
671876 ROBOFLEX-recycle 3 x 0,34 3,0 socket straight 58,8 -
671877 ROBOFLEX-recycle 3 x 0,34 5,0 socket straight 98,0 -
671879 ROBOFLEX-recycle 3 x 0,34 10,0 socket straight 196,0 -
671883 ROBOFLEX-recycle 3 x 0,34 1,0 socket angled 19,6 -
671884 ROBOFLEX-recycle 3 x 0,34 1,5 socket angled 29,4 -
671886 ROBOFLEX-recycle 3 x 0,34 3,0 socket angled 58,8 -
671887 ROBOFLEX-recycle 3 x 0,34 5,0 socket angled 98,0 -
671889 ROBOFLEX-recycle 3 x 0,34 10,0 socket angled 196,0 -
671833 ROBOFLEX-recycle 4 x 0,34 1,0 socket straight 24,2 -
671834 ROBOFLEX-recycle 4 x 0,34 1,5 socket straight 36,3 -
671836 ROBOFLEX-recycle 4 x 0,34 3,0 socket straight 72,6 -
671837 ROBOFLEX-recycle 4 x 0,34 5,0 socket straight 121,0 -
671839 ROBOFLEX-recycle 4 x 0,34 10,0 socket straight 242,0 -
671843 ROBOFLEX-recycle 4 x 0,34 1,0 socket angled 24,2 -
671844 ROBOFLEX-recycle 4 x 0,34 1,5 socket angled 36,3 -
671846 ROBOFLEX-recycle 4 x 0,34 3,0 socket angled 72,6 -
671847 ROBOFLEX-recycle 4 x 0,34 5,0 socket angled 121,0 -
671849 ROBOFLEX-recycle 4 x 0,34 10,0 socket angled 242,0 -
671854 ROBOFLEX-recycle 5 x 0,34 1,0 socket straight 30,0 -
671850 ROBOFLEX-recycle 5 x 0,34 1,5 socket straight 45,0 -
671851 ROBOFLEX-recycle 5 x 0,34 3,0 socket straight 90,0 -
671852 ROBOFLEX-recycle 5 x 0,34 5,0 socket straight 150,0 -
671853 ROBOFLEX-recycle 5 x 0,34 10,0 socket straight 300,0 -
671859 ROBOFLEX-recycle 5 x 0,34 1,0 socket angled 30,0 -
671855 ROBOFLEX-recycle 5 x 0,34 1,5 socket angled 45,0 -
671856 ROBOFLEX-recycle 5 x 0,34 3,0 socket angled 90,0 -
671857 ROBOFLEX-recycle 5 x 0,34 5,0 socket angled 150,0 -
671858 ROBOFLEX-recycle 5 x 0,34 10,0 socket angled 300,0 -

Dimensions and specifications may be changed without prior notice.

892
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 sensor cable screened both ends pre-assembled

Technical data Cable structure Properties


Approval: Bare copper stranded wire, 42 x 0.10 mm very good resistance to oil to
UL/cUL approved Cores stranded in layers DIN VDE 0473-811-404/DIN EN 60811-404
Production Polyester foil taping good resistance to acids, alkalis and
in accordance with VDE standards Screening of tinned copper braid, solvents
Temperature range: coverage approx. 85%, D-screen for not cross-linked
fixed installation -40C to +105C robot applications weld splatter resistant
flexible -30C to +105C Special compound sheath, weld-splatter recyclable
Nominal voltage: resistant, recyclable, matt, low-adhesion, halogen-free
300 V flame retardant and self-extinguishing Silicone and cadmium-free
Test voltage: to DIN VDE 0482-332-1-2, Free of substances harmful to paint
2000 V DIN EN 60332-1-2/IEC 60332-1 adhesion Substances
Minimum bending radius: Sheath colour: black very high mechanical load capacity
7.5 x cable diameter (for flexible Assembly (3-pin) abrasion resistant
installation) Core insulation polyester, black, brown, wear-resistant
Traversing speed: blue, black Highly flexible
max. 3.3 m/s for 5 m of horizontal Outer diameter 5,2 +/-0.2 mm UV-resistant
traverse path length Assembly (4-pin) ROHS conformant
Acceleration: Core insulation polyester, brown, blue, CE conformant
max. 5 m/s black, white
Flexing and torsion cycles: Outer diameter 5.5 +/-0.2 mm Note
min. 10 million. Assembly (5-pin) IP67
Torsional stress: Core insulation polyester, brown, blue, A-coded
+/- 360/m black, white, green
Outer diameter 6,0 +/-0.2 mm
plug / socket
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
671953 ROBOFLEX-recycle 3 x 0,34 1,0 plug straight / socket straight 19,6 -
671954 ROBOFLEX-recycle 3 x 0,34 1,5 plug straight / socket straight 29,4 -
671956 ROBOFLEX-recycle 3 x 0,34 3,0 plug straight / socket straight 58,8 -
671957 ROBOFLEX-recycle 3 x 0,34 5,0 plug straight / socket straight 98,0 -
671759 ROBOFLEX-recycle 3 x 0,34 10,0 plug straight / socket straight 196,0 -
671963 ROBOFLEX-recycle 4 x 0,34 1,0 plug straight / socket straight 24,2 -
671964 ROBOFLEX-recycle 4 x 0,34 1,5 plug straight / socket straight 36,3 -
671966 ROBOFLEX-recycle 4 x 0,34 3,0 plug straight / socket straight 72,6 -
671967 ROBOFLEX-recycle 4 x 0,34 5,0 plug straight / socket straight 121,0 -
671969 ROBOFLEX-recycle 4 x 0,34 10,0 plug straight / socket straight 242,0 -
671973 ROBOFLEX-recycle 5 x 0,34 1,0 plug straight / socket straight 30,0 -
671974 ROBOFLEX-recycle 5 x 0,34 1,5 plug straight / socket straight 45,0 -
671976 ROBOFLEX-recycle 5 x 0,34 3,0 plug straight / socket straight 90,0 -
671977 ROBOFLEX-recycle 5 x 0,34 5,0 plug straight / socket straight 150,0 -
671979 ROBOFLEX-recycle 5 x 0,34 10,0 plug straight / socket straight 300,0 -
671983 ROBOFLEX-recycle 3 x 0,34 1,0 plug straight / socket angled 19,6 -
671984 ROBOFLEX-recycle 3 x 0,34 1,5 plug straight / socket angled 29,4 -
671986 ROBOFLEX-recycle 3 x 0,34 3,0 plug straight / socket angled 58,8 -
671988 ROBOFLEX-recycle 3 x 0,34 5,0 plug straight / socket angled 98,0 -
671989 ROBOFLEX-recycle 3 x 0,34 10,0 plug straight / socket angled 196,0 -
671993 ROBOFLEX-recycle 4 x 0,34 1,0 plug straight / socket angled 24,2 -
671994 ROBOFLEX-recycle 4 x 0,34 1,5 plug straight / socket angled 36,3 -
671996 ROBOFLEX-recycle 4 x 0,34 3,0 plug straight / socket angled 72,6 -
671997 ROBOFLEX-recycle 4 x 0,34 5,0 plug straight / socket angled 121,0 -
671999 ROBOFLEX-recycle 4 x 0,34 10,0 plug straight / socket angled 242,0 -
672003 ROBOFLEX-recycle 5 x 0,34 1,0 plug straight / socket angled 30,0 -
672004 ROBOFLEX-recycle 5 x 0,34 1,5 plug straight / socket angled 45,0 -
672006 ROBOFLEX-recycle 5 x 0,34 3,0 plug straight / socket angled 90,0 -
672007 ROBOFLEX-recycle 5 x 0,34 5,0 plug straight / socket angled 150,0 -
672009 ROBOFLEX-recycle 5 x 0,34 10,0 plug straight / socket angled 300,0 -
672013 ROBOFLEX-recycle 3 x 0,34 1,0 plug angled / socket angled 19,6 -
672014 ROBOFLEX-recycle 3 x 0,34 1,5 plug angled / socket angled 29,4 -
672016
672017
672019
ROBOFLEX-recycle
ROBOFLEX-recycle
ROBOFLEX-recycle
3 x 0,34
3 x 0,34
3 x 0,34
3,0
5,0
10,0
plug angled / socket angled
plug angled / socket angled
plug angled / socket angled
58,8
98,0
196,0
-
-
-
U
Continuation

893
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle M12 sensor cable screened both ends pre-assembled


plug / socket
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
672023 ROBOFLEX-recycle 4 x 0,34 1,0 plug angled / socket angled 24,2 -
672024 ROBOFLEX-recycle 4 x 0,34 1,5 plug angled / socket angled 36,3 -
672026 ROBOFLEX-recycle 4 x 0,34 3,0 plug angled / socket angled 72,6 -
672027 ROBOFLEX-recycle 4 x 0,34 5,0 plug angled / socket angled 121,0 -
672029 ROBOFLEX-recycle 4 x 0,34 10,0 plug angled / socket angled 242,0 -
672033 ROBOFLEX-recycle 5 x 0,34 1,0 plug angled / socket angled 30,0 -
672034 ROBOFLEX-recycle 5 x 0,34 1,5 plug angled / socket angled 45,0 -
672036 ROBOFLEX-recycle 5 x 0,34 3,0 plug angled / socket angled 90,0 -
672037 ROBOFLEX-recycle 5 x 0,34 5,0 plug angled / socket angled 150,0 -
672039 ROBOFLEX-recycle 5 x 0,34 10,0 plug angled / socket angled 300,0 -

Dimensions and specifications may be changed without prior notice.

894
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle Twin cables M12 to M12

Technical data Cable structure Properties


Approval: Assembly (3-pin) very good resistance to oil to
UL/cUL approved Bare copper litz wire, 42 x 0.10 mm DIN VDE 0473-811-404/DIN EN 60811-404
Production Core insulation polyester, black, blue, good resistance to acids, alkalis and
in accordance with VDE standards brown solvents
Temperature range: Cores stranded in layers not cross-linked
fixed installation -40C to +105C Sheath, special mix weld splatter resistant
flexible -30C to +105C weld splatter resistant, dull, low adhesion, recyclable
Nominal voltage: flame retardant and self-extinguishing halogen-free
300 V to DIN VDE 0482-332-1-2, Silicone and cadmium-free
Test voltage: DIN EN 60332-1-2/ IEC 60332-1 Free of substances harmful to paint
2000 V Sheath colour: black adhesion Substances
Minimum bending radius: Outer diameter 4.9 +/-0.2 mm very high mechanical load capacity
7.5 x cable diameter Assembly (4-pin) abrasion resistant
(for flexible installation) Bare copper litz wire, 42 x 0.10 mm wear-resistant
Traversing speed: Core insulation polyester, black, brown, Highly flexible
max. 3.3 m/s for 5 m of horizontal white, blue UV-resistant
traverse path length Cores stranded in layers ROHS conformant
Acceleration: Sheath, special mix CE conformant
max. 5 m/s weld splatter resistant, dull, low adhesion,
Flexing and torsion cycles: flame retardant and self-extinguishing Note
min. 10 million. to DIN VDE 0482-332-1-2, * Twin cables with sensor cable
Torsional stress: DIN EN 60332-1-2/ IEC 60332-1 ROBOFLEX recycle M12 to M8 and other
+/- 360/m Sheath colour: black configurations and lengths -
Outer diameter 5,2 +/-0.2 mm available on request.
Dimensions and specifications may be changed without prior notice.

895
Pre-assembled Cables / ROBOFLEX-recycle

ROBOFLEX-recycle Twin cables M12 to M12

Technical data Cable structure Properties


Approval: Assembly (3-pin) very good resistance to oil to
UL/cUL approved Bare copper litz wire, 42 x 0.10 mm DIN VDE 0473-811-404/DIN EN 60811-404
Production Core insulation polyester, black, blue, brown good resistance to acids, alkalis and
in accordance with VDE standards Cores stranded in layers solvents
Temperature range: Sheath, special mix not cross-linked
fixed installation -40C to +105C weld splatter resistant, dull, low adhesion, weld splatter resistant
flexible -30C to +105C flame retardant and self-extinguishing recyclable
Nominal voltage: to DIN VDE 0482-332-1-2, halogen-free
300 V DIN EN 60332-1-2/ IEC 60332-1 Silicone and cadmium-free
Test voltage: Sheath colour: black Free of substances harmful to paint
2000 V Outer diameter 4.9 +/-0.2 mm adhesion Substances
Minimum bending radius: Assembly (4-pin) very high mechanical load capacity
7.5 x cable diameter (for flexible Bare copper litz wire, 42 x 0.10 mm abrasion resistant
installation) Core insulation polyester, black, brown, white, wear-resistant
Traversing speed: blue Highly flexible
max. 3.3 m/s for 5 m of horizontal traverse Cores stranded in layers UV-resistant
path length Sheath, special mix ROHS conformant
Acceleration: weld splatter resistant, dull, low adhesion, CE conformant
max. 5 m/s flame retardant and self-extinguishing
Flexing and torsion cycles: to DIN VDE 0482-332-1-2, Note
min. 10 million. DIN EN 60332-1-2/ IEC 60332-1 * Design for the Standard
Torsional stress: Sheath colour: black 2 LEDs in the colours: yellow, green;
+/- 360/m Outer diameter 5,2 +/-0.2 mm 3 LEDs in the colours: white, yellow, green -
available upon request.
** Twin cables with sensor cable
ROBOFLEX recycle M12 to M8 and other
configurations and lengths - available on
request.
Dimensions and specifications may be changed without prior notice.

896
897
CONNECTING CABLES & EXTENSIONS

Designation Properties Approvals Page

PVC Connecting cables 900

Rubber Connecting cables 901

YELLOWFLEX Connecting cables meter marking 902

PUR Connecting cables meter marking 903

Extensions/supply cables CEE extensions, cold equipment cables, PVC extensions 904

Front connector cables for Simatic S7 905

899
Pre-assembled Cables / Connecting and Extension Cables

PVC connecting cables

Technical data Cable structure Note


Temperature range Bare copper-conductor, to G = with green-yellow conductor
flexing -5C to +70C DIN VDE 0295 cl.5, fine-wire, x = without green-yellow conductor
fixed installation -40C to +70C BS 6360 cl.5, IEC 60228 cl.5 On request also with international
Nominal voltage Core insulation of PVC approval.
H03VV-F: U0/U 300/300 V Core identification to DIN VDE 0293-308 AWG sizes are approximate equivalent
H05VV-F: U0/U 300/500 V Cores stranded in layers values. The actual cross-section is in mm.
Test voltage 2000 V GN-YE conductor, 3 cores and above
Assembly Outer sheath of PVC
- End 1: Plug Sheath colour see table below
- End 2: 25 respectively 30 mm
stripped with wire end ferrule

Application
H03VV-F
This cable is highly suitable as a hand tool connection for lightweight applications. It is often
used as a connecting cable for household appliances.
H05VV-F
This cable is highly suitable as a hand tool connection for medium-weight applications. It can
also be used in wet rooms. As a connecting cable: for machine installation.

Part no. Cable type / Length Plug type Cop. AWG-No.


black white grey cross-sec. m weight
mm kg / 1000 pcs.
84412 84416 H03VVH2-F 2 x 0,75 2,0 Euro plug 28,8 19
84413 84417 H03VVH2-F 2 x 0,75 3,0 Euro plug 43,2 19
84420 84421 H03VVH2-F 2 x 0,75 5,0 Euro plug 72,0 19
84414 84418 H03VV-F 2 x 0,75 2,0 Euro plug 28,8 19
84415 84419 H03VV-F 2 x 0,75 3,0 Euro plug 43,2 19
84422 84423 H03VV-F 2 x 0,75 5,0 Euro plug 72,0 19
84424 84425 84428 H03VV-F 2 x 0,75 2,0 Central contour connector 28,8 19
84426 84427 84429 H03VV-F 2 x 0,75 3,0 Central contour connector 43,2 19
86870 84430 84431 H03VV-F 2 x 0,75 5,0 Central contour connector 72,0 19
87127 87128 84432 H05VV-F 2 x 1,0 2,0 Central contour connector 38,0 18
86765 87130 84433 H05VV-F 2 x 1,0 3,0 Central contour connector 57,0 18
86867 84434 84435 H05VV-F 2 x 1,0 5,0 Central contour connector 95,0 18
86764 87575 84436 H03VV-F 3 G 0,75 2,0 PROTECTED PLUG, straight 43,2 19
84437 84438 84439 H03VV-F 3 G 0,75 3,0 PROTECTED PLUG, straight 64,8 19
84440 84441 84442 H03VV-F 3 G 0,75 5,0 PROTECTED PLUG, straight 108,0 19
84400 84406 87725 H03VV-F 3 G 0,75 2,0 PROTECTED PLUG, angled 43,2 19
84401 84407 84446 H03VV-F 3 G 0,75 3,0 PROTECTED PLUG, angled 64,8 19
87748 84447 87277 H03VV-F 3 G 0,75 5,0 PROTECTED PLUG, angled 108,0 19
87137 87139 84451 H05VV-F 3 G 1,0 2,0 PROTECTED PLUG, straight 58,0 18
87138 87140 84452 H05VV-F 3 G 1,0 3,0 PROTECTED PLUG, straight 87,0 18
84453 84454 84455 H05VV-F 3 G 1,0 5,0 PROTECTED PLUG, straight 145,0 18
84402 84408 84459 H05VV-F 3 G 1,0 2,0 PROTECTED PLUG, angled 58,0 18
84403 84409 87410 H05VV-F 3 G 1,0 3,0 PROTECTED PLUG, angled 87,0 18
87074 87141 84460 H05VV-F 3 G 1,0 5,0 PROTECTED PLUG, angled 145,0 18
84464 84465 84466 H05VV-F 3 G 1,5 2,0 PROTECTED PLUG, straight 86,0 16
84467 84468 84469 H05VV-F 3 G 1,5 3,0 PROTECTED PLUG, straight 129,0 16
84470 84471 84472 H05VV-F 3 G 1,5 5,0 PROTECTED PLUG, straight 215,0 16
84404 84410 84475 H05VV-F 3 G 1,5 2,0 PROTECTED PLUG, angled 86,0 16
84405 84411 87503 H05VV-F 3 G 1,5 3,0 PROTECTED PLUG, angled 129,0 16
87142 87143 84476 H05VV-F 3 G 1,5 5,0 PROTECTED PLUG, angled 215,0 16

Dimensions and specifications may be changed without prior notice.

900
Pre-assembled Cables / Connecting and Extension Cables

Rubber connecting cables

Technical data Cable structure Note


Temperature range Bare copper-conductor, to G = with green-yellow conductor
flexing -30C to +60C DIN VDE 0295 cl.5, fine-wire, x = without green-yellow conductor
Nominal voltage BS 6360 cl.5, IEC 60228 cl.5 On request also with international approval.
H05RR-F / H05RN-F: U0/U 300/500 V Core insualtion of rubber AWG sizes are approximate equivalent
H07RN-F: U0/U 450/750 V Cores identification to DIN VDE 0293-308 values. The actual cross-section is in mm.
Test voltage Cores stranded in layers
H05RR-F / H05RN-F: 2000 V GN-YE conductor, 3 cores and above
H07RN-F: 2500 V Outer sheath of rubber
Assembly Sheath colour black
- End 1: Plug
- End 2: 25 respectively 30 mm
stripped with wire end ferrule

Application
H05RR-F
Lightweight rubber-sheathed cable for use as a hand tool connection and lightweight workshop tools for light to medium-weight applications in dry
and wet rooms.
H05RN-F
Medium-weight rubber-sheathed cable for use as a hand tool connection and lightweight workshop equipment for light to medium-weight applications
in dry rooms, wet rooms outdoors and in industrial water.
H07RN-F
Heavyweight rubber-sheathed cable for use on heavy equipment and tools (agricultural, construction industry). For heavyweight applications in dry
rooms, wet rooms, outdoors and in
industrial water.

Part no. Cable type / Length Plug type Cop. AWG-No.


black cross-sec. m weight
mm kg / 1000 pcs.
84481 H05RR-F 2 x 0,75 3,0 Central contour connector 43,2 18
84482 H05RR-F 2 x 0,75 5,0 Central contour connector 72,0 18
84483 H05RR-F 2 x 0,75 10,0 Central contour connector 144,0 18
87738 H05RR-F 2 x 1,0 3,0 Central contour connector 57,6 17
86961 H05RR-F 2 x 1,0 5,0 Central contour connector 96,0 17
84485 H05RR-F 2 x 1,0 10,0 Central contour connector 192,0 17
86960 H05RR-F 2 x 1,5 3,0 Central contour connector 86,4 16
87406 H05RR-F 2 x 1,5 5,0 Central contour connector 144,0 16
84487 H05RR-F 2 x 1,5 10,0 Central contour connector 288,0 16
87690 H05RR-F 3 G 0,75 3,0 PROTECTED PLUG, straight 64,8 18
84489 H05RR-F 3 G 0,75 5,0 PROTECTED PLUG, straight 108,0 18
84490 H05RR-F 3 G 0,75 10,0 PROTECTED PLUG, straight 216,0 18
84492 H05RR-F 3 G 0,75 3,0 PROTECTED PLUG, angled 64,8 18
84493 H05RR-F 3 G 0,75 5,0 PROTECTED PLUG, angled 108,0 18
84494 H05RR-F 3 G 0,75 10,0 PROTECTED PLUG, angled 216,0 18
86740 H07RN-F 3 G 1,0 3,0 PROTECTED PLUG, straight 86,4 17
87145 H07RN-F 3 G 1,0 5,0 PROTECTED PLUG, straight 144,0 17
87604 H07RN-F 3 G 1,0 10,0 PROTECTED PLUG, straight 288,0 17
84496 H07RN-F 3 G 1,0 3,0 PROTECTED PLUG, angled 86,4 17
84497 H07RN-F 3 G 1,0 5,0 PROTECTED PLUG, angled 144,0 17
84498 H07RN-F 3 G 1,0 10,0 PROTECTED PLUG, angled 288,0 17
86741 H07RN-F 3 G 1,5 3,0 PROTECTED PLUG, straight 129,6 16

U
87084 H07RN-F 3 G 1,5 5,0 PROTECTED PLUG, straight 216,0 16
84499 H07RN-F 3 G 1,5 10,0 PROTECTED PLUG, straight 432,0 16
84653 H07RN-F 3 G 1,5 3,0 PROTECTED PLUG, angled 129,6 16
84654 H07RN-F 3 G 1,5 5,0 PROTECTED PLUG, angled 216,0 16
84655 H07RN-F 3 G 1,5 10,0 PROTECTED PLUG, angled 432,0 16

Dimensions and specifications may be changed without prior notice.

901
Pre-assembled Cables / Connecting and Extension Cables

YELLOWFLEX - connecting cable meter marking

Technical data Cable structure Properties


Rubber sheathed cable adapted to Bare copper-conductor, to Increased stability
DIN VDE 0285-525-2-21 / DIN VDE 0295 cl.5, fine-wire, Tear-resistant
DIN EN 50525-2-21 BS 6360 cl.5, IEC 60228 cl.5 Resistant to
Temperature range Core insulation of rubber, EI4 to Atmospheric influences
flexing -25C to +60C DIN VDE 0207-363-1 / DIN EN 50363-1 Largely resistant to
fixed installation -30C to +60C Core identification to DIN VDE 0293-308 Oils and fats
Permissible operating temperature - up to 5 cores coloured Tests
at conductor +60C - from 6 cores, black with continuous Behaviour in fire
Nominal voltage U0/U 450/750 V white numbering to DIN VDE 0482-332-1-2
with protected fixed installation GN-YE conductor, 3 cores and above DIN EN 60332-2-1, IEC 60332-1 (equivalent
U0/U 600/1000 V Cores stranded in layers with DIN VDE 0472 part 804 test method B)
Highest permissible operating voltage optimal lay-length
in three-phase and one-phase Outer sheath of special EM2 to Note
a.c. systems U0/U 476/825 V DIN VDE 0207-363-2-1/DIN EN 50363-2-1 G = with green-yellow conductor
in direct current system Sheath colour yellow (RAL 1021) x = without green-yellow conductor.
U0/U 619/1238 V with meter marking individual marking
Test voltage 2500 V
Minimum bending radius
for fixed installation 4x cable
for guiding over roller 7,5x cable
during winding on drums 5x cable
Assembly
- End 1: Plug
- End 2: 30 mm stripped
with wire end ferrule

Application
These robust rubber sheathed cables can be used where high demands are placed flexibility and mechanical stress. For application in dry, moist and
wet rooms and in open air, in steel works and rolling mills in heating and air-conditioning systems, in the bottling industry, in machinery and plant
construction, in the chemical industry as well as for the professional and the hobby enthusiast. The choice of yellow as the sheath colour ensures
additional safety. Can be used in potentially explosive areas acc. to DIN VDE 0165.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cable type / Length Plug type Cop. AWG-No.


orange cross-sec. m weight
mm kg / 1000 pcs.
650950 YELLOWFLEX 2 x 1,0 2,0 Central contour connector 38,0 17
650951 YELLOWFLEX 2 x 1,0 3,0 Central contour connector 57,0 17
650952 YELLOWFLEX 2 x 1,0 5,0 Central contour connector 95,0 17
650953 YELLOWFLEX 2 x 1,0 10,0 Central contour connector 190,0 17
650958 YELLOWFLEX 2 x 1,5 2,0 Central contour connector 58,0 16
650959 YELLOWFLEX 2 x 1,5 3,0 Central contour connector 87,0 16
650960 YELLOWFLEX 2 x 1,5 5,0 Central contour connector 145,0 16
650961 YELLOWFLEX 2 x 1,5 10,0 Central contour connector 290,0 16
650954 YELLOWFLEX 3 G 1,0 2,0 PROTECTED PLUG, straight 58,0 17
650955 YELLOWFLEX 3 G 1,0 3,0 PROTECTED PLUG, straight 87,0 17
650956 YELLOWFLEX 3 G 1,0 5,0 PROTECTED PLUG, straight 145,0 17
650957 YELLOWFLEX 3 G 1,0 10,0 PROTECTED PLUG, straight 290,0 17
650962 YELLOWFLEX 3 G 1,5 2,0 PROTECTED PLUG, straight 86,0 16
650963 YELLOWFLEX 3 G 1,5 3,0 PROTECTED PLUG, straight 129,0 16
650964 YELLOWFLEX 3 G 1,5 5,0 PROTECTED PLUG, straight 215,0 16
650965 YELLOWFLEX 3 G 1,5 10,0 PROTECTED PLUG, straight 430,0 16

Dimensions and specifications may be changed without prior notice.

902
Pre-assembled Cables / Connecting and Extension Cables

PUR connecting cables, orange

Technical data Cable structure Note


Temperature range Bare copper-conductor, to G = with green-yellow conductor
-40C to +80C DIN VDE 0295 cl.5, fine-wire, x = without green-yellow conductor
Nominal voltage BS 6360 cl.5, IEC 60228 cl.5 AWG sizes are approximate equivalent
H05BQ-F: U0/U 300/500 V Core insualtion of rubber values. The actual cross-section is in mm.
H07BQ-F: U0/U 450/750 V Core identification to DIN VDE 0293-308
Test voltage Cores stranded in layers
H05BQ-F: 2000 V GN-YE conductor, 3 cores and above
H07BQ-F: 2500 V Outer sheath of PUR
Assembly Sheath colour orange
- End 1: Plug
- End 2: 30 mm stripped
with wire end ferrule

Application
These cables can be used for medium mechanical loads in dry, damp or wet environments, e. g. for connecting agricultural and commercial equipment
and heaters provided there is no danger of contact with the hot parts or by radiation of heat. These robust and flexible cables are used for electrical
tools such as drills and hand-held circular saws, as well as for portable motors and machinery in agriculture, at building sites, docks and refrigeration
plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. Cable type / Length Plug type Cop. AWG-No.


orange cross-sec. m weight
mm kg / 1000 pcs.
84656 H05BQ-F 2 x 0,75 2,0 Central contour connector 28,8 18
87802 H05BQ-F 2 x 0,75 3,0 Central contour connector 43,2 18
84657 H05BQ-F 2 x 0,75 5,0 Central contour connector 72,0 18
84658 H05BQ-F 2 x 0,75 10,0 Central contour connector 144,0 18
84663 H05BQ-F 2 x 1,0 2,0 Central contour connector 38,4 17
84664 H05BQ-F 2 x 1,0 3,0 Central contour connector 57,6 17
84665 H05BQ-F 2 x 1,0 5,0 Central contour connector 96,0 17
84666 H05BQ-F 2 x 1,0 10,0 Central contour connector 192,0 17
84669 H07BQ-F 2 x 1,5 2,0 Central contour connector 58,0 16
84670 H07BQ-F 2 x 1,5 3,0 Central contour connector 87,0 16
86989 H07BQ-F 2 x 1,5 5,0 Central contour connector 145,0 16
84671 H07BQ-F 2 x 1,5 10,0 Central contour connector 290,0 16
84659 H05BQ-F 3 G 0,75 2,0 PROTECTED PLUG, straight 43,2 18
84660 H05BQ-F 3 G 0,75 3,0 PROTECTED PLUG, straight 64,8 18
84661 H05BQ-F 3 G 0,75 5,0 PROTECTED PLUG, straight 108,0 18
84662 H05BQ-F 3 G 0,75 10,0 PROTECTED PLUG, straight 216,0 18
84667 H05BQ-F 3 G 1,0 2,0 PROTECTED PLUG, straight 58,0 17
86775 H05BQ-F 3 G 1,0 3,0 PROTECTED PLUG, straight 87,0 17
86774 H05BQ-F 3 G 1,0 5,0 PROTECTED PLUG, straight 145,0 17
84668 H05BQ-F 3 G 1,0 10,0 PROTECTED PLUG, straight 290,0 17
84672 H07BQ-F 3 G 1,5 2,0 PROTECTED PLUG, straight 86,0 16
86782 H07BQ-F 3 G 1,5 3,0 PROTECTED PLUG, straight 129,0 16
87548 H07BQ-F 3 G 1,5 5,0 PROTECTED PLUG, straight 215,0 16
84673 H07BQ-F 3 G 1,5 10,0 PROTECTED PLUG, straight 430,0 16

Dimensions and specifications may be changed without prior notice.

903
Pre-assembled Cables / Connecting and Extension Cables

Extensions / Supply cables CEE-Extensions / Cold equipment /


PVC-Extensions

CEE-Extensions
Part no. Cable type / Length Cable colour Plug 1 Plug 2 AWG-No.
cross-sec. m
mm
84688 H07RN-F 5 G 1,5 5,0 black CEE connector 16A CEE coupling 16A 16
84689 H07RN-F 5 G 1,5 10,0 black CEE connector 16A CEE coupling 16A 16
87164 H07RN-F 5 G 1,5 25,0 black CEE connector 16A CEE coupling 16A 16
84690 H07RN-F 5 G 2,5 5,0 black CEE connector 32A CEE coupling 32A 14
84691 H07RN-F 5 G 2,5 10,0 black CEE connector 32A CEE coupling 32A 14
87416 H07RN-F 5 G 2,5 25,0 black CEE connector 32A CEE coupling 32A 14

Part no. Cable type / Length Cable colour Plug 1 Plug 2 AWG-No.
cross-sec. m
mm
87476 H05VV-F 3 G 0,75 2,0 black PROTECTED PLUG, angled Cold device socket 19
86762 H05VV-F 3 G 0,75 2,0 grey PROTECTED PLUG, angled Cold device socket 19
84674 H05VV-F 3 G 0,75 3,0 black PROTECTED PLUG, angled Cold device socket 19
87845 H05VV-F 3 G 0,75 3,0 grey PROTECTED PLUG, angled Cold device socket 19
84675 H05VV-F 3 G 1,0 2,0 grey PROTECTED PLUG, angled Cold device socket 17
87196 H05VV-F 3 G 1,0 2,0 black PROTECTED PLUG, angled Cold device socket 17
84676 H05VV-F 3 G 1,0 3,0 grey PROTECTED PLUG, angled Cold device socket 17
87549 H05VV-F 3 G 1,0 3,0 black PROTECTED PLUG, angled Cold device socket 17

Part no. Cable type / Length Cable colour Plug 1 Plug 2 AWG-No.
cross-sec. m
mm
87445 H05VV-F 3 G 1,5 2,0 white PROTECTED PLUG, straight PROTECTED PLUG coupling 16
87919 H05VV-F 3 G 1,5 3,0 white PROTECTED PLUG, straight PROTECTED PLUG coupling 16
84178 H05VV-F 3 G 1,5 5,0 white PROTECTED PLUG, straight PROTECTED PLUG coupling 16

Dimensions and specifications may be changed without prior notice.

904
Pre-assembled Cables / Connecting and Extension Cables

Front connecting cables for Simatic S7

Cable structure Properties


Cable cores 0,75 mm in Advantages
dark blue (RAL 5010) Tremendous time savings
Printed characters in white Quick wiring
Numbers acc. to allocation in the plug Considerably easier troubleshooting
Original front connector can be Customised pre-assembled cable
completely allocated
Cores cut flush Note
Customised pre-assembly possible Other lengths, dimensions, colours
and specials conditions possible on
request

Application
These pre-assembled cables with pre-wired front connectors are highly suitable for Simatic S7 programmable logic controllers (PLC).
As opposed to past days when you had to cut to length, strip, crimp, screw in and mark, pre-wired front connectors offer the customer a host of
advantages for the Simatic S7 system.

Part no. Connection type Length Cop. AWG-No.


m weight
kg / 1000 pcs.
Front connector, 20-pole
650091 Screw fitting version 2,0 324,0 19
650200 Screw fitting version 3,0 468,0 19
650201 Screw fitting version 5,0 756,0 19
84867 Spring version 2,0 324,0 19
84868 Spring version 3,0 468,0 19
84869 Spring version 5,0 756,0 19
650202 Crimp version 2,0 324,0 19
650203 Crimp version 3,0 468,0 19
650088 Crimp version 5,0 756,0 19
Front connector, 40-pole
650092 Screw fitting version 2,0 648,0 19
650204 Screw fitting version 3,0 936,0 19
650205 Screw fitting version 5,0 1512,0 19
84870 Spring version 2,0 648,0 19
84871 Spring version 3,0 936,0 19
84872 Spring version 5,0 1512,0 19
650206 Crimp version 2,0 648,0 19
650207 Crimp version 3,0 936,0 19
650086 Crimp version 5,0 1512,0 18
Front connector, 48-pole
650208 Screw fitting version 2,0 746,0 19
650209 Screw fitting version 3,0 1077,0 19
650210 Screw fitting version 5,0 1739,0 19
650211 Spring version 2,0 746,0 19
650212 Spring version 3,0 1077,0 19
650213 Spring version 5,0 1739,0 19
84873 Crimp version 2,0 746,0 19
84874 Crimp version 3,0 1077,0 19
84875 Crimp version 5,0 1739,0 19

Dimensions and specifications may be changed without prior notice.

905
906
SPIRAL CABLES

Designation Page

PVC spiral cable 908

PUR spiral cable, black 909

PUR spiral cable, orange 911

PUR electronics spiral cable, unscreened 913

PUR electronics spiral cable, screened 915

907
Spiral Cables

PVC spiral cables

Technical data Cable structure Note


Temperature range Bare copper-conductor, to On request closed spiral lengths up to max.
flexing -5C to +70C DIN VDE 0295 cl.5, fine-wire, 5000 mm possible.
Nominal voltage BS 6360 cl.5, IEC 60228 cl.5 As well in axial construction
H03VV-F: U0/U 300/300 V Core insulation of PVC AWG sizes are approximate equivalent
H05VV-F: U0/U 300/500 V Core identification to DIN VDE 0293-308 values. The actual cross-section is in mm.
Test voltage 2000 V GN-YE conductor, 3 cores and above
Expansion ratio 1:3 Cores stranded in layers
straight ends Outer sheath of PVC
in each case 200 mm Sheath colour see table below

Application
Lighting industry
Data installations
Shops
Telecommunication

Part no. Cross-section Spiral length Cable Spiral- Cop. AWG-No.


black white mm unexpanded approx. mm outer weight
(WL in mm) approx. mm kg / 1000 pcs.
84500 84700 2 x 0,75 200 6,2 21,4 34,6 18
84502 84702 2 x 0,75 400 6,2 21,4 63,4 18
84504 84704 2 x 0,75 600 6,2 21,4 92,2 18
84506 84706 2 x 0,75 800 6,2 21,4 121,0 18
84508 84708 2 x 0,75 1000 6,2 21,4 149,8 18
84509 84709 2 x 0,75 1200 6,2 21,4 178,6 18
84510 84710 2 x 0,75 1400 6,2 21,4 207,4 18
84517 84717 3 G 0,75 200 6,6 22,2 51,9 18
84519 84719 3 G 0,75 400 6,6 22,2 95,1 18
84521 84721 3 G 0,75 600 6,6 22,2 138,3 18
84523 84723 3 G 0,75 800 6,6 22,2 181,5 18
84525 84725 3 G 0,75 1000 6,6 22,2 224,7 18
84526 84726 3 G 0,75 1200 6,6 22,2 267,8 18
84527 84727 3 G 0,75 1400 6,6 22,2 311,1 18
84534 84734 2 x 1,0 200 6,6 22,2 43,2 17
84536 84736 2 x 1,0 400 6,6 22,2 65,3 17
84538 84738 2 x 1,0 600 6,6 22,2 122,8 17
84540 84740 2 x 1,0 800 6,6 22,2 161,3 17
84542 84742 2 x 1,0 1000 6,6 22,2 199,7 17
84543 84743 2 x 1,0 1200 6,6 22,2 238,1 17
84544 84744 2 x 1,0 1400 6,6 22,2 276,5 17
84585 84785 2 x 1,5 200 7,7 26,4 69,6 16
84587 84787 2 x 1,5 400 7,7 26,4 127,0 16
84589 84789 2 x 1,5 600 7,7 26,4 185,6 16
84591 84791 2 x 1,5 800 7,7 26,4 243,6 16
84593 84793 2 x 1,5 1000 7,7 26,4 301,6 16
84594 84794 2 x 1,5 1200 7,7 26,4 359,6 16
84595 84795 2 x 1,5 1400 7,7 26,4 417,6 16
84602 84802 3 G 1,5 200 8,5 29,0 103,2 16
84604 84804 3 G 1,5 400 8,5 29,0 189,2 16
84606 84806 3 G 1,5 600 8,5 29,0 275,2 16
84608 84808 3 G 1,5 800 8,5 29,0 361,2 16
84610 84810 3 G 1,5 1000 8,5 29,0 447,2 16
84611 84811 3 G 1,5 1200 8,5 29,0 533,2 16
84612 84812 3 G 1,5 1400 8,5 29,0 619,2 16

Dimensions and specifications may be changed without prior notice.

908
Spiral Cables

PUR spiral cables black

Technical data Cable structure Note


Temperature range Bare copper-conductor, to On request closed spiral lengths up to max.
-25C to +70C DIN VDE 0295 cl.5, fine-wire, 5000 mm possible.
Nominal voltage BS 6360 cl.5, IEC 60228 cl.5 As well in axial constructio
H05BQ-F: U0/U 300/500 V Core insulation of rubber AWG sizes are approximate equivalent
H07BQ-F: U0/U 450/750 V Core identification to DIN VDE 0293-308 values. The actual cross-section is in mm.
Test voltage GN-YE conductor, 3 cores and above
H05BQ-F: 2000 V Outer sheath of PUR
H07BQ-F: 2500 V Sheath colour black
Expansion ratio 1:4
straight ends
in each case 200 mm

Application
Machine Construction
Electrical Tools
Building Industry
Handling Equipment
Entertainment Equipment
Medical devices
Measurement instruments
Rolling doors

Part no. Cross-section Spiral length Cable Spiral- Cop. AWG-No.


black mm unexpanded approx. mm outer weight
(WL in mm) approx. mm kg / 1000 pcs.
86303 2 x 0,75 500 6,5 23,0 77,8 18
86306 2 x 0,75 1000 6,5 23,0 149,8 18
86308 2 x 0,75 1400 6,5 23,0 207,4 18
86311 2 x 0,75 2000 6,5 23,0 293,8 18
86315 2 x 0,75 3000 6,5 23,0 437,8 18
86319 3 G 0,75 500 7,1 25,2 116,7 18
86322 3 G 0,75 1000 7,1 25,2 224,7 18
86324 3 G 0,75 1400 7,1 25,2 311,1 18
86327 3 G 0,75 2000 7,1 25,2 440,6 18
86331 3 G 0,75 3000 7,1 25,2 656,6 18
86335 4 G 0,75 500 7,9 28,8 156,6 18
86338 4 G 0,75 1000 7,9 28,8 301,6 18
86340 4 G 0,75 1400 7,9 28,8 417,6 18
86343 4 G 0,75 2000 7,9 28,8 591,6 18
86347 4 G 0,75 3000 7,9 28,8 881,6 18
86351 5 G 0,75 500 8,6 31,2 194,4 18
86354 5 G 0,75 1000 8,6 31,2 374,4 18
86356 5 G 0,75 1400 8,6 31,2 518,4 18
86359 5 G 0,75 2000 8,6 31,2 734,4 18
86363 5 G 0,75 3000 8,6 31,2 1094,4 18
86367 2 x 1,0 500 6,8 24,6 103,7 17
86370 2 x 1,0 1000 6,8 24,6 199,7 17
86372 2 x 1,0 1400 6,8 24,6 276,5 17
86375 2 x 1,0 2000 6,8 24,6 391,7 17
86379 2 x 1,0 3000 6,8 24,6 583,7 17
84903 3 G 1,0 500 7,2 26,4 156,6 17
84906 3 G 1,0 1000 7,2 26,4 301,6 17
84908 3 G 1,0 1400 7,2 26,4 417,6 17
84911 3 G 1,0 2000 7,2 26,4 591,6 17
84915 3 G 1,0 3000 7,2 26,4 881,6 17
86383 4 G 1,0 500 7,8 28,6 207,4 17
86386 4 G 1,0 1000 7,8 28,6 399,4 17
86388 4 G 1,0 1400 7,8 28,6 553,0 17
86391 4 G 1,0 2000 7,8 28,6 783,4 17
86395 4 G 1,0 3000 7,8 28,6 1167,4 17
86399 5 G 1,0 500 9,0 32,0 259,2 17
86402 5 G 1,0 1000 9,0 32,0 499,2 17
86404 5 G 1,0 1400 9,0 32,0 691,2 17
86407 5 G 1,0 2000 9,0 32,0 979,2 17
86411 5 G 1,0 3000 9,0 32,0 1459,2 17

Continuation
V

909
Spiral Cables

PUR spiral cables black


Part no. Cross-section Spiral length Cable Spiral- Cop. AWG-No.
black mm unexpanded approx. mm outer weight
(WL in mm) approx. mm kg / 1000 pcs.
86415 7 G 1,0 500 11,1 39,0 361,8 17
86418 7 G 1,0 1000 11,1 39,0 696,8 17
86420 7 G 1,0 1400 11,1 39,0 964,8 17
86423 7 G 1,0 2000 11,1 39,0 1366,8 17
86427 7 G 1,0 3000 11,1 39,0 2036,8 17
86463 2 x 1,5 500 8,5 30,0 156,6 16
86466 2 x 1,5 1000 8,5 30,0 301,6 16
86468 2 x 1,5 1400 8,5 30,0 417,6 16
86471 2 x 1,5 2000 8,5 30,0 591,6 16
86475 2 x 1,5 3000 8,5 30,0 881,6 16
84919 3 G 1,5 500 8,9 32,8 232,2 16
84922 3 G 1,5 1000 8,9 32,8 447,2 16
84924 3 G 1,5 1400 8,9 32,8 619,2 16
84927 3 G 1,5 2000 8,9 32,8 877,2 16
84931 3 G 1,5 3000 8,9 32,8 1307,2 16
84951 5 G 1,5 500 10,9 38,8 388,8 16
84954 5 G 1,5 1000 10,9 38,8 748,8 16
84956 5 G 1,5 1400 10,9 38,8 1036,8 16
84959 5 G 1,5 2000 10,9 38,8 1468,8 16
84963 5 G 1,5 3000 10,9 38,8 2188,8 16
84967 7 G 1,5 500 12,2 46,4 545,4 16
84970 7 G 1,5 1000 12,2 46,4 1050,4 16
84972 7 G 1,5 1400 12,2 46,4 1454,1 16
84975 7 G 1,5 2000 12,2 46,4 2060,4 16
84979 7 G 1,5 3000 12,2 46,4 3070,4 16
86479 3 G 2,5 500 10,6 38,2 388,8 14
86482 3 G 2,5 1000 10,6 38,2 748,8 14
86484 3 G 2,5 1400 10,6 38,2 1036,8 14
86487 3 G 2,5 2000 10,6 38,2 1468,8 14
86491 3 G 2,5 3000 10,6 38,2 2188,8 14

Dimensions and specifications may be changed without prior notice.

910
Spiral Cables

PUR spiral cables orange

Technical data Cable structure Note


Temperature range Bare copper-conductor, to On request closed spiral lengths up to max.
-25C to +70C DIN VDE 0295 cl.5, fine-wire, 5000 mm possible.
Nominal voltage BS 6360 cl.5, IEC 60228 cl.5 As well in axial constructionon
H05BQ-F: 300/500 V Core insulation of rubber AWG sizes are approximate equivalent
H07BQ-F: 450/750 V Core identification to DIN VDE 0293-308 values. The actual cross-section is in mm.
Test voltage GN-YE conductor, 3 cores and above
2000/2500 V Outer sheath of PUR
Expansion ratio 1:4 Sheath colour orange
straight ends
in each case 200 mm

Application
Machine Construction
Electrical Tools
Building Industry
Handling Equipment
Entertainment Equipment
Medical devices
Measurement instruments
Rolling doors

Part no. Cross-section Spiral length Cable Spiral- Cop. AWG-No.


orange mm unexpanded approx. mm outer weight
(WL in mm) approx. mm kg / 1000 pcs.
85221 2 x 0,75 300 6,5 23,0 59,0 18
85223 2 x 0,75 500 6,5 23,0 77,8 18
85226 2 x 0,75 1000 6,5 23,0 149,8 18
85229 2 x 0,75 1500 6,5 23,0 221,8 18
85236 2 x 0,75 3000 6,5 23,0 437,8 18
85238 3 G 0,75 300 7,1 25,2 73,5 18
85240 3 G 0,75 500 7,1 25,2 116,7 18
85243 3 G 0,75 1000 7,1 25,2 224,7 18
85246 3 G 0,75 1500 7,1 25,2 332,6 18
85253 3 G 0,75 3000 7,1 25,2 656,6 18
85255 4 G 0,75 300 7,9 28,8 98,6 18
85257 4 G 0,75 500 7,9 28,8 156,6 18
85260 4 G 0,75 1000 7,9 28,8 301,6 18
85263 4 G 0,75 1500 7,9 28,8 446,6 18
85270 4 G 0,75 3000 7,9 28,8 881,6 18
85272 5 G 0,75 300 8,6 31,2 122,4 18
85274 5 G 0,75 500 8,6 31,2 194,4 18
85277 5 G 0,75 1000 8,6 31,2 374,4 18
85280 5 G 0,75 1500 8,6 31,2 554,4 18
85287 5 G 0,75 3000 8,6 31,2 1094,4 18
85289 2 x 1,0 300 6,8 24,6 65,3 17
85291 2 x 1,0 500 6,8 24,6 103,7 17
85294 2 x 1,0 1000 6,8 24,6 199,7 17
85297 2 x 1,0 1500 6,8 24,6 295,7 17
85304 2 x 1,0 3000 6,8 24,6 583,7 17
85306 3 G 1,0 300 7,2 26,4 98,6 17
85308 3 G 1,0 500 7,2 26,4 156,6 17
85311 3 G 1,0 1000 7,2 26,4 301,6 17
85314 3 G 1,0 1500 7,2 26,4 446,6 17
85321 3 G 1,0 3000 7,2 26,4 881,6 17
85323 4 G 1,0 300 7,8 28,6 130,6 17
85325 4 G 1,0 500 7,8 28,6 207,4 17
85328 4 G 1,0 1000 7,8 28,6 399,4 17
85331 4 G 1,0 1500 7,8 28,6 591,4 17
85338 4 G 1,0 3000 7,8 28,6 1167,4 17
85340 5 G 1,0 300 9,0 32,0 163,2 17
85342 5 G 1,0 500 9,0 32,0 259,2 17
85345 5 G 1,0 1000 9,0 32,0 499,2 17
85348 5 G 1,0 1500 9,0 32,0 739,2 17
85355 5 G 1,0 3000 9,0 32,0 1459,2 17

Continuation

911
Spiral Cables

PUR spiral cables orange


Part no. Cross-section Spiral length Cable Spiral- Cop. AWG-No.
orange mm unexpanded approx. mm outer weight
(WL in mm) approx. mm kg / 1000 pcs.
85357 2 x 1,5 300 8,5 30,0 98,6 16
85359 2 x 1,5 500 8,5 30,0 156,6 16
85362 2 x 1,5 1000 8,5 30,0 301,6 16
85365 2 x 1,5 1500 8,5 30,0 446,6 16
85372 2 x 1,5 3000 8,5 30,0 881,6 16
85374 3 G 1,5 300 8,9 32,8 146,2 16
85376 3 G 1,5 500 8,9 32,8 232,2 16
85379 3 G 1,5 1000 8,9 32,8 447,2 16
85382 3 G 1,5 1500 8,9 32,8 662,2 16
85389 3 G 1,5 3000 8,9 32,8 1307,2 16
85408 5 G 1,5 300 10,9 38,8 244,8 16
85410 5 G 1,5 500 10,9 38,8 388,8 16
85413 5 G 1,5 1000 10,9 38,8 748,8 16
85416 5 G 1,5 1500 10,9 38,8 1108,8 16
85423 5 G 1,5 3000 10,9 38,8 2188,8 16
85425 7 G 1,5 300 12,6 46,4 343,4 16
85427 7 G 1,5 500 12,6 46,4 545,4 16
85430 7 G 1,5 1000 12,6 46,4 1050,4 16
85433 7 G 1,5 1500 12,6 46,4 1555,4 16
85440 7 G 1,5 3000 12,6 46,4 3070,4 16
85442 12 G 1,5 300 16,6 65,2 588,2 16
85444 12 G 1,5 500 16,6 65,2 934,2 16
85447 12 G 1,5 1000 16,6 65,2 1799,2 16
85450 12 G 1,5 1500 16,6 65,2 2664,2 16
85457 12 G 1,5 3000 16,6 65,2 5259,2 16
85459 3 G 2,5 300 10,6 38,2 244,8 14
85461 3 G 2,5 500 10,6 38,2 388,8 14
85464 3 G 2,5 1000 10,6 38,2 748,8 14
85467 3 G 2,5 1500 10,6 38,2 1108,8 14
85474 3 G 2,5 3000 10,6 38,2 2188,8 14
85493 5 G 2,5 300 13,2 48,4 408,0 14
85495 5 G 2,5 500 13,2 48,4 648,0 14
85498 5 G 2,5 1000 13,2 48,4 1248,0 14
85501 5 G 2,5 1500 13,2 48,4 1848,0 14
85508 5 G 2,5 3000 13,2 48,4 3648,0 14

Dimensions and specifications may be changed without prior notice.

912
Spiral Cables

PUR electronic spiral cables unscreened

Technical data Cable structure Note


Temperature range Bare copper-conductor, to On request closed spiral lengths up to max.
-25C to +70C DIN VDE 0295 cl.6, extra fine-wire, 5000 mm possible.
Nominal voltage BS 6360 cl.6, IEC 60228 cl.6 As well in axial construction
up tp 0,14 mm 300 V Core insulation of TPE-E AWG sizes are approximate equivalent
from 0,25 mm 500 V Core identification to DIN 47100 values. The actual cross-section is in mm.
Test voltage Cores stranded in layers
1000 V Outer sheath of PUR
Expansion ratio 1:4 Colour black
straight ends
in each case 200 mm

Application
Handling Equipment
Entertainment Equipment
Medical devices
Measurement instruments
Rolling doors
In all fields in which
low-current cables are used

Part no. Cross-section Spiral length Cable Spiral- Cop. AWG-No.


black mm unexpanded approx. mm outer weight
(WL in mm) approx. mm kg / 1000 pcs.
85550 2 x 0,14 300 3,5 13,0 9,2 26
85551 2 x 0,14 400 3,5 13,0 11,9 26
85552 2 x 0,14 500 3,5 13,0 15,6 26
85555 2 x 0,14 1000 3,5 13,0 28,1 26
85566 4 x 0,14 300 4,0 14,0 18,4 26
85567 4 x 0,14 400 4,0 14,0 23,8 26
85568 4 x 0,14 500 4,0 14,0 29,2 26
85571 4 x 0,14 1000 4,0 14,0 56,2 26
85574 5 x 0,14 300 4,4 15,8 22,8 26
85575 5 x 0,14 400 4,4 15,8 29,5 26
85576 5 x 0,14 500 4,4 15,8 36,2 26
85579 5 x 0,14 1000 4,4 15,8 69,7 26
85582 6 x 0,14 300 4,9 17,8 27,5 26
85583 6 x 0,14 400 4,9 17,8 36,7 26
85584 6 x 0,14 500 4,9 17,8 43,8 26
85587 6 x 0,14 1000 4,9 17,8 84,2 26
85590 7 x 0,14 300 5,2 18,4 32,0 26
85591 7 x 0,14 400 5,2 18,4 42,4 26
85592 7 x 0,14 500 5,2 18,4 50,8 26
85595 7 x 0,14 1000 5,2 18,4 97,8 26
85598 8 x 0,14 300 5,4 19,8 36,7 26
85599 8 x 0,14 400 5,4 19,8 47,5 26
85600 8 x 0,14 500 5,4 19,8 58,3 26
85603 8 x 0,14 1000 5,4 19,8 112,3 26
85638 2 x 0,25 300 3,9 13,8 16,3 24
85639 2 x 0,25 400 3,9 13,8 21,1 24
85640 2 x 0,25 500 3,9 13,8 25,9 24
85643 2 x 0,25 1000 3,9 13,8 49,9 24
85654 4 x 0,25 300 4,6 17,2 36,7 24
85655 4 x 0,25 400 4,6 17,2 42,2 24
85656 4 x 0,25 500 4,6 17,2 51,8 24
85659 4 x 0,25 1000 4,6 17,2 99,8 24
85662 5 x 0,25 300 5,4 19,8 40,8 24
85663 5 x 0,25 400 5,4 19,8 52,8 24
85664 5 x 0,25 500 5,4 19,8 64,8 24
85667 5 x 0,25 1000 5,4 19,8 124,8 24
85670 6 x 0,25 300 5,5 20,0 48,9 24
85671 6 x 0,25 400 5,5 20,0 63,4 24
85672 6 x 0,25 500 5,5 20,0 77,8 24
85675 6 x 0,25 1000 5,5 20,0 149,8 24

Continuation

913
Spiral Cables

PUR electronic spiral cables unscreened


Part no. Cross-section Spiral length Cable Spiral- Cop. AWG-No.
black mm unexpanded approx. mm outer weight
(WL in mm) approx. mm kg / 1000 pcs.
85686 8 x 0,25 300 6,4 23,8 65,3 24
85687 8 x 0,25 400 6,4 23,8 84,5 24
85688 8 x 0,25 500 6,4 23,8 103,7 24
85691 8 x 0,25 1000 6,4 23,8 199,7 24
85702 12 x 0,25 300 6,9 24,8 97,9 24
85703 12 x 0,25 400 6,9 24,8 126,7 24
85704 12 x 0,25 500 6,9 24,8 155,5 24
85707 12 x 0,25 1000 6,9 24,8 299,5 24
85726 2 x 0,5 300 4,6 16,2 32,6 20
85727 2 x 0,5 400 4,6 16,2 42,3 20
85728 2 x 0,5 500 4,6 16,2 51,8 20
85731 2 x 0,5 1000 4,6 16,2 99,8 20
85742 4 x 0,5 300 5,0 18,0 65,3 20
85743 4 x 0,5 400 5,0 18,0 84,5 20
85744 4 x 0,5 500 5,0 18,0 103,7 20
85747 4 x 0,5 1000 5,0 18,0 201,8 20
85758 6 x 0,5 300 6,2 22,4 97,9 20
85759 6 x 0,5 400 6,2 22,4 126,7 20
85760 6 x 0,5 500 6,2 22,4 155,5 20
85763 6 x 0,5 1000 6,2 22,4 299,5 20
85774 8 x 0,5 300 7,4 26,8 130,6 20
85775 8 x 0,5 400 7,4 26,8 169,0 20
85776 8 x 0,5 500 7,4 26,8 207,4 20
85779 8 x 0,5 1000 7,4 26,8 399,4 20
85790 12 x 0,5 300 8,2 29,4 195,8 20
85791 12 x 0,5 400 8,2 29,4 254,3 20
85792 12 x 0,5 500 8,2 29,4 311,1 20
85795 12 x 0,5 1000 8,2 29,4 599,1 20

Dimensions and specifications may be changed without prior notice.

914
Spiral Cables

PUR electronic spiral cables screened

Technical data Cable structure Note


Temperature range Bare copper-conductor, to On request closed spiral lengths up to max.
-25C to +70C DIN VDE 0295 cl.6, extra fine-wire, 5000 mm possible.
Nominal voltage BS 6360 cl.6, IEC 60228 cl.6 As well in axial construction
up to 0,14 mm 300 V Core insualtion of TPE-E AWG sizes are approximate equivalent
from 0,25 mm 500 V Core identification to DIN 47100 values. The actual cross-section is in mm.
Test voltage Cores stranded in layers
2000 V Overall screening
Expansion ratio 1:4 Outer sheath of PUR
straight ends Sheath colour black
in each case 200 mm

Application
Handling Equipment
Entertainment Equipment
Medical devices
Measurement instruments
Rolling doors
In all fields in which
low-current cables are used

Part no. Cross-section Spiral length Cable Spiral- Cop. AWG-No.


black mm unexpanded approx. mm outer weight
(WL in mm) approx. mm kg / 1000 pcs.
85900 2 x 0,14 300 3,8 13,6 30,6 26
85901 2 x 0,14 400 3,8 13,6 39,6 26
85902 2 x 0,14 500 3,8 13,6 48,6 26
85905 2 x 0,14 1000 3,8 13,6 93,6 26
600154 3 x 0,14 300 4,1 15,2 44,2 26
600155 3 x 0,14 400 4,1 15,2 55,8 26
600156 3 x 0,14 500 4,1 15,2 67,5 26
600157 3 x 0,14 1000 4,1 15,2 135,0 26
85916 4 x 0,14 300 4,6 16,2 47,6 26
85917 4 x 0,14 400 4,6 16,2 61,6 26
85918 4 x 0,14 500 4,6 16,2 75,6 26
85921 4 x 0,14 1000 4,6 16,2 145,6 26
85924 5 x 0,14 300 4,6 17,2 54,4 26
85925 5 x 0,14 400 4,6 17,2 70,4 26
85926 5 x 0,14 500 4,6 17,2 86,4 26
85929 5 x 0,14 1000 4,6 17,2 166,4 26
85932 6 x 0,14 300 5,2 19,4 64,6 26
85933 6 x 0,14 400 5,2 19,4 83,6 26
85934 6 x 0,14 500 5,2 19,4 102,6 26
85937 6 x 0,14 1000 5,2 19,4 197,6 26
85940 7 x 0,14 300 5,5 20,0 68,0 26
85941 7 x 0,14 400 5,5 20,0 88,0 26
85942 7 x 0,14 500 5,5 20,0 108,0 26
85945 7 x 0,14 1000 5,5 20,0 208,0 26
85948 8 x 0,14 300 5,6 20,2 74,8 26
85949 8 x 0,14 400 5,6 20,2 96,8 26
85950 8 x 0,14 500 5,6 20,2 118,8 26
85953 8 x 0,14 1000 5,6 20,2 228,8 26
85980 2 x 0,25 300 4,5 16,0 51,0 24
85981 2 x 0,25 400 4,5 16,0 66,0 24
85982 2 x 0,25 500 4,5 16,0 81,0 24
85985 2 x 0,25 1000 4,5 16,0 156,0 24
85988 4 x 0,25 300 5,0 18,0 74,8 24
85989 4 x 0,25 400 5,0 18,0 96,8 24
85990 4 x 0,25 500 5,0 18,0 118,8 24
85993 4 x 0,25 1000 5,0 18,0 228,8 24
85996 5 x 0,25 300 5,4 19,8 85,0 24
85997 5 x 0,25 400 5,4 19,8 110,0 24
85998 5 x 0,25 500 5,4 19,8 135,0 24
86001 5 x 0,25 1000 5,4 19,8 260,0 24

Continuation

915
Spiral Cables

PUR electronic spiral cables screened


Part no. Cross-section Spiral length Cable Spiral- Cop. AWG-No.
black mm unexpanded approx. mm outer weight
(WL in mm) approx. mm kg / 1000 pcs.
86004 6 x 0,25 300 5,7 20,4 102,0 24
86005 6 x 0,25 400 5,7 20,4 132,0 24
86006 6 x 0,25 500 5,7 20,4 162,0 24
86009 6 x 0,25 1000 5,7 20,4 312,0 24
86012 8 x 0,25 300 6,5 23,0 119,0 24
86013 8 x 0,25 400 6,5 23,0 154,0 24
86014 8 x 0,25 500 6,5 23,0 189,0 24
86017 8 x 0,25 1000 6,5 23,0 364,0 24
86020 12 x 0,25 300 7,1 26,2 170,0 24
86021 12 x 0,25 400 7,1 26,2 220,0 24
86022 12 x 0,25 500 7,1 26,2 270,0 24
86025 12 x 0,25 1000 7,1 26,2 520,0 24
86036 2 x 0,5 300 5,5 20,0 78,2 20
86037 2 x 0,5 400 5,5 20,0 101,2 20
86038 2 x 0,5 500 5,5 20,0 124,2 20
86041 2 x 0,5 1000 5,5 20,0 239,2 20
86044 4 x 0,5 300 5,8 21,6 153,0 20
86045 4 x 0,5 400 5,8 21,6 198,0 20
86046 4 x 0,5 500 5,8 21,6 243,0 20
86049 4 x 0,5 1000 5,8 21,6 648,0 20
86052 6 x 0,5 300 7,0 26,0 231,2 20
86053 6 x 0,5 400 7,0 26,0 299,2 20
86054 6 x 0,5 500 7,0 26,0 367,2 20
86057 6 x 0,5 1000 7,0 26,0 707,2 20
86060 8 x 0,5 300 8,0 29,0 289,0 20
86061 8 x 0,5 400 8,0 29,0 374,0 20
86062 8 x 0,5 500 8,0 29,0 459,0 20
86065 8 x 0,5 1000 8,0 29,0 884,0 20
86068 12 x 0,5 300 8,8 31,6 380,8 20
86069 12 x 0,5 400 8,8 31,6 492,8 20
86070 12 x 0,5 500 8,8 31,6 604,8 20
86073 12 x 0,5 1000 8,8 31,6 1164,8 20

Dimensions and specifications may be changed without prior notice.

916
SHIPWIRING & MARINE CABLES

Designation Properties Approvals Page

Ships Power Cables MGSGO halogen-free, with Cu-screen 921

Light Marine Power Cables XLFMKK with Cu-screen 922

Marine Power Cables LMGSGO halogen-free, with Cu-screen 923

Ships Telephone Cables FMGCH 250 V (FMGCG*) halogen-free in accordance with DIN 89 159/98 924

Marine Telecommunication Cables FMGSGO halogen-free, with Cu-screen 925


Marine Telecommunication Cables
with single screen high cross-talk attenuation, halogen-free 926
FMSGSGO 250 V
Light Marine Telecommunication Cables
halogen-free, 2xCu-screen 927
LFMGSSGO
Light Marine Telecommunication Cables
halogen-free, 2xCu-screen 928
LFMSGSSGO
Ships Wiring Cables-SY single core 929
Ships Wiring Cables-SY multicore 930
Ships Power Cables MPRX 0.6/1 kV in accordance with IEC 60092-353, halogen-free 931

Ships Power Cables MPRXCX 0.6/1 kV in accordance with IEC 60092-353, halogen-free, screened 932

SHIPFLEX 512 Drag chain cable, halogen-free, EMC-preferred type, meter marking 933

SHIPFLEX 330
Drag chain cable, halogen-free, EMC-preferred type, meter marking 934

SHIPFLEX 340 Drag chain cable, halogen-free, EMC-preferred type, meter marking 935

SHIPFLEX 109
Cable drag chain, single core, halogen-free. EMC-preferred type (-C-type) meter marked 936

SHIPFLEX 109
Drag chain cable, halogen-free, EMC-preferred type, meter marking 937

SHIPFLEX 113 Drag chain cable, halogen-free, EMC-preferred type, meter marking 938

SHIPFLEX 121
Drag chain cable, halogen-free, EMC-preferred type, meter marking 939

919
SELECTION TABLE - DRAG CHAIN CABLES

ng
in

xi

g
/s 2
ce

fle

in
/
an

ex
ge U
(m
-
es ist

lta 0 /

- fl
us

)
-c t d

vo U
/s
di

io
)

C)
g ge
en

(m
ra

at
or

(
tin lta
er
m

re
in

s
25
e

el

nt
ra vo
ee

le

ui CSA
ov

nd

tu

s
c

yc
)

al
to

le
sp

ac

pe l

ra
ia
m

O ina
be

ov
r

.c
up

va
te

eq L/
er

pe
.

ge
.

ax

ax
ou

pr
ax
ax
m

om
.

at
in

U
m
=

Ap
M

M
0

Pa
M
M

M
M
(D
(1

Te
N
Drag chain cables for ship & offshore applications
SHIPFLEX 512 100 7.5 x D 4 10 11 Mio TPE/CU/PUR 1000V -40 to +80 UL/CSA 933 -
SHIPFLEX 330

100 7.5 x D 4 10 11 Mio TPE/CU/PUR 300V -40 to +80 UL/CSA 934 -
SHIPFLEX 340 100 7.5 x D 4 10 11 Mio TPE/CU/PUR 300V -40 to +80 UL/CSA 935 -
SHIPFLEX 109 100 7.5 x D 4 10 11 Mio TPE/CU/PUR 1000V -40 to +80 UL/CSA 936 -
SHIPFLEX 109

100 7.5 x D 4 10 11 Mio TPE/CU/PUR 1000V -40 to +80 UL/CSA 937 -
SHIPFLEX 113 100 7.5 x D 4 10 11 Mio TPE/CU/PUR 1000V -40 to +80 UL/CSA 938 -
SHIPFLEX 121 100 7.5 x D 4 10 11 Mio TPE/CU/PUR 1000V -40 to +80 UL/CSA 939 -

A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).

The selection table is intended as an initial orientation.


Please see the relevant page of the catalogue for detailed information on the product properties and the selection tables cables in drag chains,
see pages 1030 and 1031.

920
Shipwiring and Marine Cables

Ships Telephone Cables FMGCH 250 V


halogen-free according to DIN 89 159/99

Technical data Cable structure Properties


acc.to DIN 89159/ edition 1998 Bare copper-conductor, to Flame retardant according to SOLAS
and IEC 60092-375 DIN VDE 0295 cl.2, multi-wire, definition (according to IEC 60332-3
Operating temperature BS 6360 cl.2, IEC 60228 cl.2 category A)
at conductor max. +85C HEPR core insulation (Hard grade EPR) Approved by
Nominal voltage 250 V Cores per pair blue/white, printed with Association of German Electrical Engineer
Insulation resistance numbers, starting in center with number 1 Germanischer Lloyd
1400 MOhm x km Cores stranded in pairs with Lloyds Register of Shipping
Minimum bending radius optimal lay-length American Bureau of Shipping
5x cable Pairs stranded in layers with Det Norske Veritas
optimal lay-length Bureau Veritas, Russian
Common sheath with foil wrapping Maritime Register of Shipping
Bare copper braided screen and Registro Italiano Navale are
Foil wrapping in preparation
Outher sheath of Polyolefin basis-compound
Sheath colour green
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
For measurement, control, regulation, control and alarm systems; radio, positioning and messaging systems. For fixed installation on ships in rooms
and on open decks.

Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
59138 1 x 2 x 0,75 8,5 62,0 90,0 18 59142 10 x 2 x 0,75 18,5 319,0 470,0 18
59139 2 x 2 x 0,75 9,0 87,0 130,0 18 59143 14 x 2 x 0,75 21,0 445,0 610,0 18
59140 4 x 2 x 0,75 13,0 153,0 230,0 18 59144 19 x 2 x 0,75 24,0 525,0 770,0 18
59141 7 x 2 x 0,75 15,5 230,0 340,0 18 59145 24 x 2 x 0,75 27,0 663,0 950,0 18

Dimensions and specifications may be changed without prior notice. (RW01)

Suitable accessories can be found in Chapter X.


Cable Gland - HSK-PVDF

924
Shipwiring and Marine Cables

Ships Wiring Cables-SY single cores

Technical data Cable structure Properties


Special PVC single cores acc. to Bare copper-conductor, to self-extinguishing and flame retardant
DIN VDE 0250 DIN VDE 0295 cl.5, fine-wire, acc. to DIN VDE 0482-332-1-2,
Temperature range BS 6360 cl.5, IEC 60228 cl.5 DIN EN 60332-1-2, IEC 60332-1 (equivalent
flexing +5C to +70C PVC core insulation DIN VDE 0472 part 804 test method B)
fixed installation -40C to +70C Tinned steel-wire braided screening Oil resistant according DIN VDE 0250
Nominal voltage 250 V PVC outer sheath Approved by
Test voltage 1500 V Sheath colour grey (RAL 7001) Germanischer Lloyd
Minimum bending radius
7,5x cable Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
A connection and a connection cable for measuring and control devices for communication systems, production lines, conveyor systems for fixed and
variable connection in humid, wet and dry areas.
These PVC single cores are also suitable for use in ship building.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
59450 1x6 8,3 57,4 148,0 10 59454 1 x 35 15,2 335,0 565,0 2
59451 1 x 10 10,3 95,8 221,0 8 59455 1 x 50 18,1 479,5 788,0 1
59452 1 x 16 10,3 153,4 293,0 6 59456 1 x 70 21,1 671,0 1061,0 2/0
59453 1 x 25 13,7 239,5 447,0 4 59457 1 x 95 22,8 910,0 1355,0 3/0

Dimensions and specifications may be changed without prior notice. (RW01)

Suitable accessories can be found in Chapter X.


Cable Gland - HSK-PVDF

929
Shipwiring and Marine Cables

Ships Wiring Cables-SY stranded type

Technical data Cable structure Properties


Special PVC cables Bare copper-conductor, to Extensively oil resistant.
Temperature range DIN VDE 0295 cl.5, fine-wire, Chemical Resistance - see table Technical
flexing +5C to +70C BS 6360 cl.5, IEC 60228 cl.5 Informations
fixed installation -40C to +70C Core insulation of PVC self-extinguishing and flame retardant
Nominal voltage 250 V compound type YI2 acc. to acc. to DIN VDE 0482-332-1-2,
Test voltage 3000 V DIN VDE 0207 part 4 DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius Cores colour coded to DIN VDE 0293 or DIN VDE 0472 part 804 test method B)
7,5x cable black cores with continuous white numbering Approved by
Core stranded in layers with Germanischer Lloyd
optimal lay-length
Inner sheath of PVC Note
Galvanized steel-wire braided overall AWG sizes are approximate equivalent
screening values. The actual cross-section is in mm.
Outer sheath of PVC
compound type YM2 acc. to
DIN VDE 0207 part 5
Sheath colour grey (RAL 7001)

Application
Ideally suitedn for for fixed installation but also for the variable use of manufacturing lines, machine tools, conveyor systems and robotic assembly
lines. A line that can also be used in shipbuilding.The galvanized steel braid protects against mechanical stress and simultaneously effective against
electrical interference.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
59460 2 x 1,5 9,7 28,7 146,0 16 59466 4 x 2,5 13,3 95,8 298,0 14
59461 3 x 1,5 10,1 43,1 166,0 16 59467 5 x 2,5 14,3 120,0 355,0 14
59462 4 x 1,5 10,8 57,5 198,0 16 59468 4x4 16,2 153,5 358,0 12
59463 5 x 1,5 11,6 71,9 230,0 16 59469 5x4 17,5 193,0 535,0 12
59464 7 x 1,5 13,3 100,6 299,0 16 59470 4x6 18,4 230,3 595,0 10
59465 3 x 2,5 11,6 72,1 231,0 14 59471 5x6 19,7 288,0 714,0 10

Dimensions and specifications may be changed without prior notice. (RW01)

Suitable accessories can be found in Chapter X.


Cable Gland - HSK-PVDF

930
Shipwiring and Marine Cables

Ships Power Cables MPRX 0,6/1kV according to IEC 60092-353,


halogen-free

Technical data Cable structure Properties


acc. to IEC 60092-353 Bare copper-conductor, to Colour code
Operating temperature DIN VDE 0295 cl.2, multi-wire, 1 core: BK
at conductor max. +85C BS 6360 cl.2, IEC 60228 cl.2 2 cores: BN, BU
Min. installation temperature Core insulation of cross-linked polyethylene 3 cores: BN, BK, GY
-10C Cores stranded in layers with 4 cores: BU, BN, BK, GY
Nominal voltage optimal lay-length 5 to 24 core cable: all cores black coloured,
U0/U 0,6/1 kV Outer sheath of Polyolefin basis-compound printed with numbers, starting in center
Minimum bending radius Sheath colour black with number 1
4x cable Approved by
Germanischer Lloyd, Lloyds Register of
Shipping, American Bureau of Shipping,
Det Norske Veritas, Bureau Veritas,
Russian Maritime Register of Shipping
and Registro Italiano Navale
Tests
Flame-test to IEC 60332-3 cat. A and
IEEE 45-18.13
Smoke density to IEC 61034
Halogen-free to 60754-1
Corrosiveness of combustion gases to
IEC 60754-2
Flame retardant according to SOLAS
definition (according to IEC 60332-3
category A and IEEE 45-18.13)

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
For fixed installation on ships and offshore-units in all locations below the upper metallic deck.
Particularly suitable for installation on passenger ships.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
59654 1x4 5,5 - 8,0 38,0 70,0 12 59681 3 x 25 19,0 - 21,5 720,0 970,0 4
59655 1x6 6,0 - 8,5 58,0 95,0 10 59682 3 x 35 20,5 - 23,5 1008,0 1290,0 2
59656 1 x 10 7,0 - 9,5 96,0 140,0 8 59683 3 x 50 24,0 - 27,0 1440,0 1720,0 1
59657 1 x 16 8,0 - 10,5 154,0 200,0 6 59684 3 x 70 26,5 - 29,5 2016,0 2450,0 2/0
59658 1 x 25 9,5 - 12,0 240,0 320,0 4 59685 3 x 95 30,5 - 34,0 2736,0 3305,0 3/0
59659 1 x 35 10,5 - 13,0 336,0 420,0 2 59686 3 x 120 33,5 - 37,5 3456,0 4140,0 4/0
59660 1 x 50 12,0 - 14,5 480,0 560,0 1 59687 4 x 1,5 8,5 - 11,0 58,0 130,0 16
59661 1 x 70 14,0 - 16,5 672,0 780,0 2/0 59688 4 x 2,5 10,0 - 12,5 96,0 180,0 14
59662 1 x 95 16,0 - 19,0 912,0 1030,0 3/0 59689 4x4 11,0 - 13,5 154,0 245,0 12
59663 1 x 120 18,0 - 21,0 1152,0 1290,0 4/0 59690 4x6 12,0 - 14,5 230,0 345,0 10
59664 1 x 150 20,0 - 23,5 1440,0 1590,0 300 kcmil 59691 4 x 10 14,5 - 17,0 384,0 535,0 8
59665 1 x 185 22,0 - 25,5 1776,0 1960,0 350 kcmil 59692 4 x 16 17,0 - 19,5 614,0 795,0 6
59666 1 x 240 25,0 - 28,5 2304,0 2560,0 500 kcmil 59693 4 x 25 21,0 - 24,0 960,0 1300,0 4
59667 1 x 300 27,5 - 31,5 2880,0 3200,0 600 kcmil 59694 4 x 35 23,0 - 26,0 1344,0 1725,0 2
59668 2 x 1,5 7,0 - 9,5 29,0 80,0 16 59695 4 x 50 27,0 - 30,0 1920,0 2310,0 1
59669 2 x 2,5 8,0 - 10,5 48,0 105,0 14 59696 4 x 70 31,0 - 34,5 2688,0 3275,0 2/0
59670 2x4 9,0 - 11,5 77,0 145,0 12 59697 4 x 95 35,5 - 39,5 3648,0 4445,0 3/0
59671 2x6 10,0 - 12,5 115,0 190,0 10 59698 5 x 1,5 9,5 - 12,0 72,0 165,0 16
59672 2 x 10 12,5 - 15,0 192,0 290,0 8 59699 5 x 2,5 10,5 - 13,0 120,0 225,0 14
59673 2 x 16 14,5 - 17,0 307,0 430,0 6 59700 7 x 1,5 10,5 - 13,0 101,0 205,0 16
59674 2 x 25 18,0 - 20,5 480,0 680,0 4 59701 10 x 1,5 13,5 - 16,0 144,0 290,0 16
59675 3 x 1,5 8,0 - 10,5 43,0 100,0 16 59702 12 x 1,5 14,0 - 17,0 173,0 330,0 16
59676 3 x 2,5 9,0 - 11,5 72,0 140,0 14 59703 14 x 1,5 14,5 - 17,5 202,0 375,0 16
59677 3x4 10,0 - 12,5 115,0 190,0 12 59704 16 x 1,5 15,5 - 18,5 230,0 440,0 16
59678 3x6 11,0 - 13,5 173,0 260,0 10 59705 19 x 1,5 16,5 - 19,5 274,0 500,0 16
59679 3 x 10 13,0 - 15,5 288,0 410,0 8 59706 24 x 1,5 19,5 - 22,5 346,0 630,0 16
59680 3 x 16 15,5 - 18,0 461,0 600,0 6

Dimensions and specifications may be changed without prior notice. (RW01) W

931
Shipwiring and Marine Cables

Ships Power Cables MPRXCX 0,6/1kV according to


IEC 60092-353, halogen-free, screened

Technical data Cable structure Properties


acc. to IEC 60092-353 Bare copper-conductor, to Colour code
Operating temperature DIN VDE 0295 cl.2, multi-wire, 1 core: BK
at conductor max. +85C BS 6360 cl.2, IEC 60228 cl.2 2 cores: BN, BU
Min. installation temperature Core insulation of cross-linked polyethylene 3 cores: BN, BK, GY
-10C Cores stranded in layers with optimal 4 cores: BU, BN, BK, GY
Nominal voltage lay-length 5- to 24 core cable: all cores black coloured,
U0/U 0,6/1 kV Foil wrapping printed with numbers, starting in center
Minimum bending radius Bare copper screened braiding with number 1
4x cable Outer sheath of Polyolefin basis-compound Approved by
Tests Sheath colour black Germanischer Lloyd, Lloyds Register of
Flame-test to IEC 60332-3 cat. A Shipping, American Bureau of Shipping,
and IEEE 45-18.13 Det Norske Veritas, Bureau Veritas,Russian
Smoke density to IEC 61034 Maritime Register of Shipping and Registro
Halogen-free to 60754-1 Italiano Navale
Corrosiveness of combustion gases Flame retardant according to SOLAS
acc. to IEC 60754-2 definition (according to IEC 60332-3
category A and IEEE 45-18.13)

Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
3-core cables with green-yellow marked
core and/or as MPRXCX 331 (insulation
integrity to IEC 60331) also available.

Application
For fixed installation on ships and offshore-units in all locations below the upper metallic deck. Particularly suitable for installation on passenger ships.
The good screening qualities of the copper braid also reduce radio interferences and electrical influences to electronic installations.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
59707 1x4 6,9 - 8,4 81,0 105,0 12 59734 3 x 25 21,2 - 23,2 924,0 950,0 4
59708 1x6 7,5 - 9,5 104,0 130,0 10 59735 3 x 35 20,8 - 23,8 1233,0 1470,0 2
59709 1 x 10 8,7 - 10,7 149,0 180,0 8 59736 3 x 50 24,3 - 26,8 1703,0 1870,0 1
59710 1 x 16 9,5 - 11,5 214,0 250,0 6 59737 3 x 70 27,6 - 30,1 2413,0 2650,0 2/0
59711 1 x 25 11,7 - 13,4 311,0 380,0 4 59738 3 x 95 31,8 - 34,3 3192,0 3500,0 3/0
59712 1 x 35 12,6 - 15,1 416,0 480,0 2 59739 3 x 120 34,3 - 36,8 3975,0 4300,0 4/0
59713 1 x 50 14,6 - 17,1 572,0 660,0 1 59740 4 x 1,5 10,1 - 11,6 147,0 200,0 16
59714 1 x 70 16,9 - 19,4 779,0 900,0 2/0 59741 4 x 2,5 11,2 - 12,7 190,0 240,0 14
59715 1 x 95 18,6 - 21,1 1034,0 1170,0 3/0 59742 4x4 12,3 - 13,8 284,0 350,0 12
59716 1 x 120 19,7 - 22,2 1316,0 1410,0 4/0 59743 4x6 14,0 - 16,0 371,0 450,0 10
59717 1 x 150 22,6 - 25,1 1615,0 1750,0 300 kcmil 59744 4 x 10 17,2 - 19,2 545,0 670,0 8
59718 1 x 185 24,7 - 27,2 1968,0 2160,0 350 kcmil 59745 4 x 16 19,4 - 21,4 796,0 950,0 6
59719 1 x 240 27,9 - 30,4 2506,0 2770,0 500 kcmil 59746 4 x 25 23,8 - 25,8 1170,0 1470,0 4
59720 1 x 300 30,2 - 32,7 3345,0 3440,0 600 kcmil 59747 4 x 35 23,0 - 25,5 1578,0 1930,0 2
59721 2 x 1,5 8,3 - 9,8 105,0 130,0 16 59748 4 x 50 26,0 - 28,5 2278,0 2500,0 1
59722 2 x 2,5 9,1 - 10,6 132,0 160,0 14 59749 4 x 70 31,5 - 34,0 3090,0 3550,0 2/0
59723 2x4 10,3 - 11,8 170,0 205,0 12 59750 4 x 95 35,5 - 38,0 4110,0 4600,0 3/0
59724 2x6 12,1 - 14,1 217,0 290,0 10 59751 5 x 1,5 10,9 - 12,4 171,0 225,0 16
59725 2 x 10 14,9 - 16,9 400,0 307,0 8 59752 5 x 2,5 12,1 - 13,6 220,0 330,0 14
59726 2 x 16 16,7 - 18,7 471,0 560,0 6 59753 7 x 1,5 11,7 - 13,2 209,0 310,0 16
59727 2 x 25 20,3 - 22,3 670,0 840,0 4 59754 10 x 1,5 14,5 - 16,0 318,0 400,0 16
59728 3 x 1,5 8,8 - 10,3 125,0 160,0 16 59755 12 x 1,5 15,3 - 16,8 353,0 440,0 16
59729 3 x 2,5 10,1 - 11,6 161,0 200,0 14 59756 14 x 1,5 16,5 - 18,0 394,0 500,0 16
59730 3x4 11,1 - 12,6 215,0 250,0 12 59757 16 x 1,5 17,7 - 19,2 432,0 550,0 16
59731 3x6 12,1 - 14,1 282,0 360,0 10 59758 19 x 1,5 18,3 - 19,8 486,0 620,0 16
59732 3 x 10 14,8 - 16,8 417,0 520,0 8 59759 24 x 1,5 20,0 - 21,5 601,0 770,0 16
59733 3 x 16 17,6 - 19,6 636,0 750,0 6

Dimensions and specifications may be changed without prior notice. (RW01)

932
Shipwiring and Marine Cables / Lloyds Register

SHIPFLEX 512 cable for drag chain, halogen-free, EMC prefered


type, meter marking

Technical data Cable structure Properties


Special screened drag chain cable Bare copper-conductor, to Flame retardant to DIN VDE 0482-332-1-2,
UL-Style 20234 DIN VDE 0295 cl.6, extra fine-wire, DIN EN 60332-1-2/ IEC 60332-1(equivalent
Temperature range BS 6360 cl.6, IEC 60228 cl.6 DIN VDE 0472 part 804 test method B)
flexing -40C to +80C Special core insulation Halogen-free to DIN VDE 0482 part 267/
fixed installation -40C to +80C Black cores with continuous white DIN EN 50267-2-1/IEC 60754-1 (equivalent
Installation temperature numbering to DIN VDE 0293 DIN VDE 0472 part 815)
min. -25C GN-YE conductor, 3 cores and above Oil resistant to IEC 60092-350,
Nominal voltage UL 1000 V in the outer layer appendix F
Insulation resistance Cores stranded in layers with optimal Behaviour at low temperature at -40C to
min. 100 MOhm x km selected lay-length IEC 60092-350, appendix E
Minimum bending radius Braided screen of tinned copper wires, Weather, ozon and UV-resistant
7,5x cable coverage approx. 85 %, optional aluminium The materials used in manufacture are
Coupling resistance foil under the braid cadmium-free and contain no silicone
max. 250 Ohm/km Full polyurethane outer sheath to and free from substances harmful to
Radiation resistance UL std. 1581 Tab. 50227 the wetting properties of lacquers
up to 100x106 cJ/kg (up to 100 Mrad) Sheath colour grey (RAL 7001)
with meter marking Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
HELUKABEL SHIPFLEX 512 is a new developed and successfully tested screened special drag chain cable which meets the requirements of the strict
standards for application in offshore-areas. For this two - line standard there is a Lloyds Register approval . The outer sheath insulation of
non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions. For applications which go beyond standard
solutions we recommend that you fill out our especially developed questionnaire for drag chains. Before installation in cable drag chains please read
the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
19864 2 x 0,5 20 6,3 35,0 50,0 19896 12 G 1,5 16 13,8 267,0 363,0
19865 3 G 0,5 20 6,5 42,0 60,0 19897 18 G 1,5 16 16,2 374,0 496,0
19866 4 G 0,5 20 7,0 47,0 64,0 19898 25 G 1,5 16 19,0 526,0 724,0
19867 5 G 0,5 20 7,5 56,0 79,0 19899 36 G 1,5 16 21,5 702,0 1190,0
19868 7 G 0,5 20 8,5 69,0 101,0 19900 2 x 2,5 14 9,5 96,0 136,0
19869 12 G 0,5 20 10,0 108,0 164,0 19901 3 G 2,5 14 10,3 144,0 179,0
19870 18 G 0,5 20 11,5 145,0 227,0 19902 4 G 2,5 14 11,3 149,0 201,0
19871 25 G 0,5 20 13,5 240,0 331,0 19903 5 G 2,5 14 12,4 181,0 232,0
19872 36 G 0,5 20 15,2 318,0 457,0 19904 7 G 2,5 14 14,4 255,0 357,0
19873 2 x 0,75 19 7,0 40,0 65,0 19905 12 G 2,5 14 17,5 441,0 586,0
19874 3 G 0,75 19 7,2 52,0 71,0 19906 18 G 2,5 14 20,3 604,0 1064,0
19875 4 G 0,75 19 7,8 60,0 82,0 19907 25 G 2,5 14 24,2 793,0 1411,0
19876 5 G 0,75 19 8,5 71,0 97,0 19908 36 G 2,5 14 27,2 1034,0 1623,0
19877 7 G 0,75 19 9,6 91,0 141,0 19909 3G4 12 11,5 174,0 257,0
19878 12 G 0,75 19 11,5 142,0 217,0 19910 4G4 12 12,4 230,0 324,0
19879 18 G 0,75 19 13,0 212,0 304,0 19911 5G4 12 13,5 274,0 401,0
19880 25 G 0,75 19 15,8 281,0 420,0 19912 6G4 12 15,2 295,0 456,0
19881 36 G 0,75 19 17,5 350,0 535,0 19913 7G4 12 16,3 316,0 511,0
19882 2x1 18 7,4 50,0 69,0 19914 3G6 10 13,5 240,0 343,0
19883 3G1 18 7,7 60,0 84,0 19915 4G6 10 15,2 305,0 427,0
19884 4G1 18 8,5 71,0 104,0 19916 5G6 10 16,5 442,0 562,0
19885 5G1 18 9,0 88,0 130,0 19917 6G6 10 17,8 471,0 628,0
19886 7G1 18 10,4 111,0 160,0 19918 7G6 10 19,5 505,0 692,0
19887 12 G 1 18 12,4 184,0 270,0 19919 3 G 10 8 17,1 367,0 731,0
19888 18 G 1 18 14,3 260,0 391,0 19920 4 G 10 8 19,0 549,0 992,0
19889 25 G 1 18 17,0 349,0 547,0 19921 5 G 10 8 20,7 607,0 1014,0
19890 36 G 1 18 19,0 510,0 790,0 19922 6 G 10 8 22,0 711,0 1241,0
19891 2 x 1,5 16 8,0 63,0 90,0 19923 7 G 10 8 24,0 820,0 1491,0
19892 3 G 1,5 16 8,3 80,0 109,0 19924 3 G 16 6 19,8 692,0 1004,0
19893 4 G 1,5 16 9,2 97,0 132,0 19925 4 G 16 6 21,8 840,0 1296,0
19894 5 G 1,5 16 10,0 119,0 169,0 19926 5 G 16 6 24,0 1050,0 1658,0
19895 7 G 1,5 16 11,6 147,0 219,0

Dimensions and specifications may be changed without prior notice. (RW01) W

933
Shipwiring and Marine Cables / Lloyds Register

SHIPFLEX 330 cable for drag chain, halogen-free, EMC prefered


type, meter marking

Technical data Cable structure Properties


Special screened drag chain cable Bare copper-conductor, to Flame retardant to DIN VDE 0482-332-1-2,
UL-Style 20233 DIN VDE 0295 cl.6, extra fine-wire, DIN EN 60332-1-2/ IEC 60332-1 (equivalent
Temperature range BS 6360 cl.6, IEC 60228 cl.6 DIN VDE 0472 part 804 test method B)
flexing -40C to +80C Special core insulation Halogen-free to DIN VDE 0482 part 267/
fixed installation -40C to +80C coloured cores to DIN 47100 DIN EN 50267-2-1/IEC 60754-1 (equivalent
Installation temperature Cores stranded in layers with optimal DIN VDE 0472 part 815)
min. -25C selected lay-length Oil resistant to IEC 60092-350,
Nominal voltage Core wrapping between the layers of appendix F
VDE U0/U 300/500 V stranding Behaviour at low temperature at -40 to
UL 300 V Braided screen of tinned copper wires, IEC 60092-350, appendix E
Insulation resistance coverage approx. 85 %, optional Weather, ozon and UV-resistant
min. 100 MOhm x km aluminium foil under the screen The materials used in manufacture are
Minimum bending radius Full polyurethane outer sheath to cadmium-free and contain no silicone
7,5x cable UL std. 1581 Tab. 50227 and free from substances harmful to
Coupling resistance Sheath colour grey (RAL 7001) the wetting properties of lacquers
max. 250 Ohm/km with meter marking
Radiation resistance Note
up to 100x106 cJ/kg (up to 100 Mrad) AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
HELUKABEL SHIPFLEX 330 is a new developed and successfully tested special drag chain cable with overall screening which meets the requirements
of the strict standards for application in offshore-areas. For this two-line standard there is a Lloyds Register approval. The outer sheath insulation
of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions. For applications which go beyond standard
solutions we recommend that you fill out our especially developed questionnaire for drag chains. Before installation in cable drag chains please read
the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
19846 2 x 0,25 24 5,0 14,9 38,0 19855 2 x 0,34 22 5,2 18,1 45,0
19847 3 x 0,25 24 5,2 18,8 44,0 19856 3 x 0,34 22 5,5 28,7 60,0
19848 4 x 0,25 24 5,5 21,3 51,0 19857 4 x 0,34 22 5,8 35,7 76,0
19849 5 x 0,25 24 5,8 31,0 68,0 19858 5 x 0,34 22 6,5 39,1 82,0
19850 7 x 0,25 24 6,7 39,6 82,0 19859 7 x 0,34 22 7,2 52,7 110,0
19851 12 x 0,25 24 8,0 59,1 124,0 19860 12 x 0,34 22 8,5 76,4 166,0
19852 18 x 0,25 24 9,0 78,4 150,0 19861 18 x 0,34 22 10,0 99,7 216,0
19853 25 x 0,25 24 10,8 101,0 204,0 19862 25 x 0,34 22 12,0 155,0 305,0
19854 36 x 0,25 24 11,5 126,4 230,0 19863 36 x 0,34 22 13,0 188,0 340,0

Dimensions and specifications may be changed without prior notice. (RW01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

934
Shipwiring and Marine Cables / Lloyds Register

SHIPFLEX 340 cable for drag chain, halogen-free, EMC prefered


type, meter marking

Technical data Cable structure Properties


Special screened drag chain cable, Bare copper-conductor, to Flame retardant to DIN VDE 0482-332-1-2,
stranded in pairs DIN VDE 0295 cl.6, extra fine-wire, DIN EN 60332-1-2/ IEC 60332-1 (equivalent
UL-Style 20233 BS 6360 cl.6, IEC 60228 cl.6 DIN VDE 0472 part 804 test method B)
Temperature range Special coreinsulation Halogen-free to DIN VDE 0482 part 267/
flexing -40C to +80C Colour coded to DIN 47100 DIN EN 50267-2-1/IEC 60754-1 (equivalent
fixed installation -40C to +80C Cores stranded in pairs, pairs stranded DIN VDE 0472 part 815)
Installation temperature torsion-free in layers with optimal Oil resistant to IEC 60092-350,
min. -25C lay-length appendix F
Nominal voltage Core wrapping between the layers of Behaviour at low temperature at -40C to
VDE U0/U 300/500 V stranding IEC 60092-350, appendix E
UL 300 V Braided screen of tinned copper wires, Weather, ozon and UV-resistant
Insulation resistance coverage approx. 85 %, optional The materials used in manufacture are
min. 100 MOhm x km aluminium foil under the screen cadmium-free and contain no silicone
Minimum bending radius Full polyurethane outer sheath to and free from substances harmful to
7,5x cable UL std. 1581 Tab. 50227 the wetting properties of lacquers
Coupling resistance Sheath colour grey (RAL 7001)
max. 250 Ohm/km with meter marking Note
Radiation resistance AWG sizes are approximate equivalent
up to 100x106 cJ/kg (up to 100 Mrad) values. The actual cross-section is in mm.

Application
HELUKABEL SHIPFLEX 340 is a new developed and successfully tested special drag chain cable with overall screening which meets the requirements
of the strict standards for application in offshore-areas. For this two - line standard there is a Lloyds Register approval. The outer sheath insulation
of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions. For applications which go beyond standard
solutions we recommend that you fill out our especially developed questionnaire for drag chains. Before installation in cable drag chains please read
the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.pairs x AWG-No. Outer Cop. Weight Part no. No.pairs x AWG-No. Outer Cop. Weight
no.cores x approx. mm weight approx. no.cores x approx. mm weight approx.
cross-sec. kg / km kg / km cross-sec. kg / km kg / km
mm mm
19927 2 x 2 x 0,25 24 6,8 32,0 60,0 19948 5 x 2 x 0,5 20 9,7 86,0 160,0
19928 3 x 2 x 0,25 24 7,1 38,0 70,0 19949 6 x 2 x 0,5 20 10,6 103,0 170,0
19929 4 x 2 x 0,25 24 7,5 43,0 82,0 19950 7 x 2 x 0,5 20 11,5 117,0 191,0
19930 5 x 2 x 0,25 24 8,0 51,0 99,0 19951 12 x 2 x 0,5 20 13,5 199,0 361,0
19931 6 x 2 x 0,25 24 8,5 72,0 126,0 19952 18 x 2 x 0,5 20 15,7 265,0 427,0
19932 7 x 2 x 0,25 24 9,2 75,0 135,0 19953 25 x 2 x 0,5 20 18,2 344,0 740,0
19933 12 x 2 x 0,25 24 11,4 117,0 189,0 19954 2 x 2 x 0,75 19 9,0 61,0 102,0
19934 18 x 2 x 0,25 24 13,5 148,0 248,0 19955 3 x 2 x 0,75 19 9,5 87,0 144,0
19935 25 x 2 x 0,25 24 15,0 233,0 343,0 19956 4 x 2 x 0,75 19 10,3 95,0 160,0
19936 2 x 2 x 0,34 22 7,4 41,0 81,0 19957 5 x 2 x 0,75 19 11,2 115,0 193,0
19937 3 x 2 x 0,34 22 7,7 52,0 100,0 19958 6 x 2 x 0,75 19 12,1 137,0 218,0
19938 4 x 2 x 0,34 22 8,4 59,0 119,0 19959 7 x 2 x 0,75 19 13,0 153,0 298,0
19939 5 x 2 x 0,34 22 9,1 67,0 135,0 19960 12 x 2 x 0,75 19 16,0 261,0 406,0
19940 6 x 2 x 0,34 22 10,0 86,0 163,0 19961 18 x 2 x 0,75 19 18,0 374,0 519,0
19941 7 x 2 x 0,34 22 10,5 94,0 170,0 19962 2x2x1 18 10,0 73,0 120,0
19942 12 x 2 x 0,34 22 12,2 122,0 220,0 19963 3x2x1 18 10,4 94,0 161,0
19943 18 x 2 x 0,34 22 14,4 197,0 277,0 19964 4x2x1 18 11,8 118,0 184,0
19944 25 x 2 x 0,34 22 16,5 238,0 400,0 19965 5x2x1 18 12,6 139,0 217,0
19945 2 x 2 x 0,5 20 8,0 53,0 100,0 19966 6x2x1 18 13,6 188,0 295,0
19946 3 x 2 x 0,5 20 8,4 73,0 131,0 19967 7x2x1 18 14,8 204,0 311,0
19947 4 x 2 x 0,5 20 9,0 77,0 149,0 19968 12 x 2 x 1 18 18,0 324,0 602,0

Dimensions and specifications may be changed without prior notice. (RW01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

935
Shipwiring and Marine Cables / Lloyds Register

SHIPFLEX 109 cable for drag chain, halogen-free, EMC prefered


type (-C-Type) , meter marking

Technical data Cable structure Properties


Special drag chain cable Bare copper-conductor, to Flame retardant to DIN VDE 0482-332-1-2,
UL-Style 20234 DIN VDE 0295 cl.6, extra fine-wire, DIN EN 60332-1-2/ IEC 60332-1 (equivalent
Temperature range BS 6360 cl.6, IEC 60228 cl.6 DIN VDE 0472 part 804 test method B)
flexing -40C to +80C Special core insulation Halogen-free to DIN VDE 0482 part 267/
fixed installation -40C to +80C Colour black or green-yellow DIN EN 50267-2-1/IEC 60754-1 (equivalent
Installation temperature Screened type with braided screen of DIN VDE 0472 part 815)
min. -25C tinned copper wires, coverage approx. 85 % Oil resistant to IEC 60092-350, appendix F
Nominal voltage Full polyurethane outer sheath to Behaviour at low temperature at -40C to
to VDE U0/U 0,6/1 kV UL std. 1581 Tab. 50227 IEC 60092-350, appendix E
UL 1000 V Sheath colour orange (RAL 2003) Weather, ozon and UV-resistant
Insulation resistance with meter marking The materials used in manufacture are
min. 100 MOhm x km cadmium-free and contain no silicone
Minimum bending radius and free from substances harmful to
7,5x cable the wetting properties of lacquers
Coupling resistance
(for -C-type) Note
max. 250 Ohm/km AWG sizes are approximate equivalent
Radiation resistance values. The actual cross-section is in mm.
up to 100x106 cJ/kg (up to 100 Mrad)

Application
HELUKABEL SHIPFLEX 109 Single is a new developed and successfully tested special drag chain cable which meets the requirements of the strict
standards for application in offshore-areas. For this two - line standard there is a Lloyds Register approval . The outer sheath insulation of
non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions. For applications which go beyond standard
solutions we recommend that you fill out our especially developed questionnaire for drag chains. Before installation in cable drag chains please read
the installation instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
SHIPFLEX 109 unscreened SHIPFLEX 109 screened
Part no. No.cores x AWG-No. Core Outer Cop. Weight Part no. No.cores x AWG-No. Core Outer Cop. Weight
cross-sec. colour approx. weight approx. cross-sec. colour approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
21388 1x6 10 black 6,9 58,0 108,0 19798 1x6 10 black 7,6 72,0 140,0
21374 1G6 10 Green-yellow 6,9 58,0 108,0 21330 1G6 10 Green-yellow 7,6 72,0 140,0
21389 1 x 10 8 black 8,3 96,0 170,0 19799 1 x 10 8 black 9,1 130,0 225,0
21375 1 G 10 8 Green-yellow 8,3 96,0 170,0 21331 1 G 10 8 Green-yellow 9,1 130,0 225,0
21390 1 x 16 6 black 9,5 154,0 240,0 19800 1 x 16 6 black 10,2 190,0 295,0
21376 1 G 16 6 Green-yellow 9,5 154,0 240,0 21332 1 G 16 6 Green-yellow 10,2 190,0 295,0
21391 1 x 25 4 black 11,3 240,0 370,0 19801 1 x 25 4 black 12,1 260,0 415,0
21377 1 G 25 4 Green-yellow 11,3 240,0 370,0 21333 1 G 25 4 Green-yellow 12,1 260,0 415,0
21392 1 x 35 2 black 12,7 336,0 490,0 19802 1 x 35 2 black 13,5 405,0 610,0
21378 1 G 35 2 Green-yellow 12,7 336,0 490,0 21334 1 G 35 2 Green-yellow 13,5 405,0 610,0
21393 1 x 50 1 black 15,0 480,0 665,0 19803 1 x 50 1 black 15,9 560,0 817,0
21379 1 G 50 1 Green-yellow 15,0 480,0 665,0 21335 1 G 50 1 Green-yellow 15,9 560,0 817,0
21394 1 x 70 2/0 black 16,3 672,0 910,0 19804 1 x 70 2/0 black 17,3 780,0 1065,0
21380 1 G 70 2/0 Green-yellow 16,3 672,0 910,0 21336 1 G 70 2/0 Green-yellow 17,3 780,0 1065,0
21395 1 x 95 3/0 black 18,8 912,0 1190,0 19805 1 x 95 3/0 black 19,5 1030,0 1340,0
21381 1 G 95 3/0 Green-yellow 18,8 912,0 1190,0 21337 1 G 95 3/0 Green-yellow 19,5 1030,0 1340,0
21396 1 x 120 4/0 black 20,9 1152,0 1530,0 19806 1 x 120 4/0 black 21,8 1285,0 1735,0
21382 1 G 120 4/0 Green-yellow 20,9 1152,0 1530,0 21338 1 G 120 4/0 Green-yellow 21,8 1285,0 1735,0
21397 1 x 150 300 kcmil black 23,2 1440,0 1720,0 19807 1 x 150 300 kcmil black 24,1 1430,0 1910,0
21383 1 G 150 300 kcmil Green-yellow 23,2 1440,0 1720,0 21339 1 G 150 300 kcmil Green-yellow 24,1 1430,0 1910,0
21398 1 x 185 350 kcmil black 25,7 1776,0 2280,0 19808 1 x 185 350 kcmil black 26,5 1940,0 2610,0
21384 1 G 185 350 kcmil Green-yellow 25,7 1776,0 2280,0 21406 1 G 185 350 kcmil Green-yellow 26,5 1940,0 2610,0
21399 1 x 240 500 kcmil black 28,2 2304,0 2895,0 19809 1 x 240 500 kcmil black 29,2 2530,0 3274,0
21404 1 G 240 500 kcmil Green-yellow 28,2 2304,0 2895,0 21410 1 G 240 500 kcmil Green-yellow 29,2 2530,0 3274,0

Dimensions and specifications may be changed without prior notice. (RW01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

936
Shipwiring and Marine Cables / Lloyds Register

SHIPFLEX 109 cable for drag chain, halogen-free, EMC prefered


type, meter marking

Technical data Cable structure Properties


Special screened drag chain cable Bare copper-conductor, to Flame retardant to DIN VDE 0482-332-1-2,
UL-Style 20234 DIN VDE 0295 cl.6, extra fine-wire, DIN EN 60332-1-2/ IEC 60332-1 (equivalent
Temperature range BS 6360 cl.6, IEC 60228 cl.6 DIN VDE 0472 part 804 test method B)
flexing -40C to +80C Special core insulation Halogen-free to DIN VDE 0482 part 267/
fixed installation -40C to +80C Black cores imprinted with U1, V2, W3 DIN EN 50267-2-1/IEC 60754-1 (equivalent
Installation temperature GN-YE conductor depends on DIN VDE 0472 part 815)
min. -25C conductor cross-section may cut into thirds Oil resistant to IEC 60092-350,
Nominal voltage Cores stranded together with optimal appendix F
to VDE U0/U 0,6/1 kV lay-length Behaviour at low temperature at -40C to
UL 1000 V Core wrapping between the layers of IEC 60092-350, appendix E
Insulation resistance stranding Weather, ozon and UV-resistant
min. 200 MOhm x km Braided screening of tinned copper wires, The materials used in manufacture are
Minimum bending radius coverage approx. 85% cadmium-free and contain no silicone
7,5x cable Full polyurethane outer sheath to and free from substances harmful to
Coupling resistance UL std. 1581 Tab. 50227 the wetting properties of lacquers
max. 250 Ohm/km Sheath colour orange (RAL 2003)
Radiation resistance with meter marking Note
up to 100x106 cJ/kg (up to 100 Mrad) AWG sizes are approximate equivalent
values. The actual cross-section is in mm.

Application
HELUKABEL SHIPFLEX 109 is a new developed and successfully tested special drag chain cable with overall screening which meets the requirements
of the strict standards for application in offshore-areas. For this two-line standard there is a Lloyds Register approval. The outer sheath insulation
of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions. For applications which go beyond standard
solutions we recommend that you fill out our especially developed questionnaire for drag chains. Before installation in cable drag chains please read
the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
19810 4G1 18 9,0 84,0 124,0 19817 4 G 25 4 27,6 1180,0 1660,0
19811 4 G 1,5 16 10,5 105,0 175,0 19818 4 G 35 2 32,7 1600,0 2400,0
19812 4 G 2,5 14 11,7 157,0 265,0 19819 4 G 50 1 37,0 2165,0 2600,0
19813 4G4 12 13,4 231,0 390,0 19820 4 G 70 2/0 43,0 3196,0 4600,0
19814 4G6 10 15,6 332,0 570,0 19969 3 G 95 3/0 41,0 3090,0 4480,0
19815 4 G 10 8 19,2 527,0 804,0 19821 4 G 95 3/0 48,0 4606,0 5350,0
19816 4 G 16 6 23,9 794,0 1450,0

Dimensions and specifications may be changed without prior notice. (RW01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

937
Shipwiring and Marine Cables / Lloyds Register

SHIPFLEX 113 cable for drag chain, halogen-free, EMC prefered


type, meter marking

Technical data Cable structure Properties


Special screened drag chain cable Bare copper-conductor, to Flame retardant to DIN VDE 0482-332-1-2,
UL-Style 20234 DIN VDE 0295 cl.6, extra fine-wire, DIN EN 60332-1-2/ IEC 60332-1 (equivalent
Temperature range BS 6360 cl.6, IEC 60228 cl.6 DIN VDE 0472 part 804 test method B)
flexing -40C to +80C Special core insulation Halogen-free to DIN VDE 0482 part 267/
fixed istallation -40C to +80C Black power supply cores with imprint U1, DIN EN 50267-2-1/IEC 60754-1 (equivalent
Installation temperature V2, W3 DIN VDE 0472 part 815)
min. -25C GN-YE conductor, depends of the Oil resistant to IEC 60092-350,
Nominal voltage diameter of the conductor appendix F
to VDE U0/U 0,6/1 kV Black control cores with white numbers 5,6 Behaviour at low temperature at -40C to
UL 1000 V Screening of the control cores in pairs IEC 60092-350, appendix E
Insulation resistance wrapped with plastic aluminium foil, and Weather, ozon and UV-resistant
min. 20 MOhm x km tinned copper braided screening, approx. The materials used in manufacture are
Minimum bending radius coverage 85% cadmium-free and contain no silicone
7,5x cable Control cores stranded in pairs and laid up and free from substances harmful to
Coupling resistance in layers together with the power supply the wetting properties of lacquers
max. 250 Ohm/km cores with optimal lay length and stabilising
Radiation resistance filler
up to 100x106 cJ/kg (up to 100 Mrad) Core wrapping between the layers of
stranding
Braided screening of tinned copper wires,
optimal coverage approx. 85 %
Full polyurethane outer sheath to
UL std. 1581 Tab. 50227
Sheath colour orange (RAL 2003)
with meter marking

Application
HELUKABEL SHIPFLEX 113 is a new developed and successfully tested screened special drag chain cable which meets the requirements of the strict
standards for application in offshore-areas. This kind of cable combines the feeding cores with the control cores. For this two-line standard there is a
Lloyds Register approval. The outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental
conditions. For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag
chains. Before installation in cable drag chains please read the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
19822 ( 4 G 1,5 + (2 x 1,0)) 11,5 138,0 254,0 - 19830 ( 4 G 6 + (2 x 1,5)) 17,0 358,0 607,0 -
19827 ( 4 G 1,5 + (2 x 1,5)) 12,0 148,0 265,0 - 19826 ( 4 G 10 + (2 x 1,0)) 20,0 574,0 912,0 -
19823 ( 4 G 2,5 + (2 x 1,0)) 13,0 176,0 328,0 - 19831 ( 4 G 10 + (2 x 1,5)) 20,5 584,0 924,0 -
19828 ( 4 G 2,5 + (2 x 1,5)) 14,0 187,0 339,0 - 19832 ( 4 G 16 + (2 x 1,5)) 24,0 825,0 1205,0 -
19824 ( 4 G 4 + (2 x 1,0)) 14,5 258,0 460,0 - 19833 ( 4 G 25 + (2 x 1,5)) 28,5 1283,0 1510,0 -
19829 ( 4 G 4 + (2 x 1,5)) 15,0 268,0 475,0 - 19834 ( 4 G 35 + (2 x 1,5)) 32,0 1850,0 2005,0 -
19825 ( 4 G 6 + (2 x 1,0)) 17,0 348,0 596,0 - 19835 ( 4 G 50 + (2 x 1,5)) 37,0 2540,0 2890,0 -

Dimensions and specifications may be changed without prior notice. (RW01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

938
Shipwiring and Marine Cables / Lloyds Register

SHIPFLEX 121 cable for drag chain, halogen-free, EMC prefered


type, meter marking

Technical data Cable structure Properties


Special screened drag chain cable Bare copper-conductor, to Flame retardant to DIN VDE 0482-332-1-2,
UL-Style 20234 DIN VDE 0295 cl.6, extra fine-wire, DIN EN 60332-1-2/ IEC 60332-1 (equivalent
Temperature range BS 6360 cl.6, IEC 60228 cl.6 DIN VDE 0472 part 804 test method B)
flexing -40C to +80C Special core insulation Halogen-free to DIN VDE 0482 part 267/
fixed installation -40C to +80C Black power supply cores with imprint U1, DIN EN 50267-2-1/IEC 60754-1 (equivalent
Installation temperature V2, W3 DIN VDE 0472 part 815)
min. -25C GN-YE conductor, depends of the Oil resistant to IEC 60092-350,
Nominal voltage diameter of the conductor appendix F
to VDE U0/U 0,6/1 kV Black control cores with white numbers 5,6 Behaviour at low temperature at-40C to
UL 1000 V and 7,8 IEC 60092-350, appendix E
Insulation resistance Screening of the control cores in pairs Weather, ozon and UV-resistant
min. 200 MOhm x km wrapped with plastic aluminium foil, and The materials used in manufacture are
Minimum bending radius tinned copper braided screening, cadmium-free and contain no silicone
7,5x cable coverage approx. 85% and free from substances harmful to
Coupling resistance Control cores stranded in pairs and laid up the wetting properties of lacquers
max. 250 Ohm/km in layers together with the power supply
Radiation resistance cores with optimal lay length and stabilising
up to 100x106 cJ/kg (up to 100 Mrad) filler
Core wrapping between the layers of
stranding
Braided screening of tinned copper wires,
coverage approx. 85 %
Full polyurethane outer sheath to
UL std. 1581 Tab. 50227
Sheath colour orange (RAL 2003)
with meter marking

Application
HELUKABEL SHIPFLEX 121 is a new developed and successfully tested screened special drag chain cable which meets the requirements of the strict
standards for application in offshore-areas. This kind of cable combines the feeding cores with the control cores. For this two - line standard there is
a Lloyds Register approval. The outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental
conditions. For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag
chains. Before installation in cable drag chains please read the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.

Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
19836 ( 4 G 1 + 2 x (2 x 0,75)) 12,5 148,0 254,0 - 19841 ( 4 G 10 + (2 x 1,5) + (2 x 1,0)) 22,0 610,0 915,0 -
19837 ( 4 G 1,5 + 2 x (2 x 0,75)) 13,0 170,0 290,0 - 19842 ( 4 G 16 + 2 x (2 x 1,5)) 25,0 904,0 1226,0 -
19838 ( 4 G 2,5 + 2 x (2 x 1,0)) 15,0 229,0 336,0 - 19843 ( 4 G 25 + 2 x (2 x 1,5)) 29,0 1323,0 1595,0 -
19839 ( 4 G 4 + (2 x 1,5) + (2 x 1,0)) 17,0 318,0 485,0 - 19844 ( 4 G 35 + 2 x (2 x 1,5)) 33,0 1621,0 2196,0 -
19840 ( 4 G 6 + (2 x 1,5) + (2 x 1,0)) 18,5 445,0 615,0 - 19845 ( 4 G 50 + 2 x (2 x 1,5)) 37,0 2585,0 2995,0 -

Dimensions and specifications may be changed without prior notice. (RW01)

Suitable accessories can be found in Chapter X.


Cable Gland - HELUTOP HT-E

939
CABLE ACCESSORIES

Cable glands 942

Cable protection tube systems 968

Shrink tubes 976

Cable ties 980

Core end sleeves & cable lugs 986

PV-male and female cable couplers 1000

Tools 1002

X
941
CABLE GLANDS

Designation Properties Approvals Page

HELUTOP HT Cable gland 944

HELUTOP HT-MS
Cable gland 946

HT-E Cable gland 948

HELUTOP MS-EP EMC cable gland 949

HELUTOP MS-EP4
EMC cable gland 950

HELUTOP HT-Clean Stainless steel cable gland 951

HELUTOP HT-Clean EMV


Stainless steel cable gland 952

HELUTOP HT-PA-EX Cable gland, hazardous area 953

HELUTOP HT-MS-EX-d
Cable gland, hazardous area, pressure resistant 954

HELUTOP HT-MS Plus Cable gland 955

HSK-PVDF Cable gland 956

KVA-XXL-MS Cable gland 958

KVA-XXL-MS-E EMC cable gland 959

STK-F Flat cable gland 960

STS-F Flat cable gland 961

KMK-PA-MB Lock nut with collar 962

KM Lock nut 963

KM-INOX Lock nut 965

KM-EMV EMC lock nut 966

X
943
Cable Glands / made of plastic for standard applications

HELUTOP HT cable gland

HELUTOP HT Material Technical data


The plastic cable gland with vibration protection. Polyamide PA 6 Protection class: IP 68 - 5 bar / IP 69K
Seal: Chloroprene-rubber (CR)
Application Temperature range: -20C up to +100C
Plant and machine construction halogen-free
Robot construction phosphor-free Test standard: EN50262
Automation technology silicone-free
Vehicle construction and shipbuilding cadmium-free
Rail technology
Installation technology Properties
Control cabinet construction Optimum strain relief through clamping plates
Easy to assemble
Large clamping areas

Note
Details on the individual tests appear in section Dimensions
Technical Information. G Thread size
GL Thread length
SW Spanner size
metric thread
Part no. Part no. Part no. Size Cable Thread Spanner Unit
light grey dark grey black Metr. from / to length size
RAL 7035 RAL 7001 RAL 9005 mm mm mm
93908 93923 93937 M12 x 1,5 3,0 - 6,5 6,0 15 100 -
93909 93924 93938 M16 x 1,5 4,0 - 8,0 8,0 19 50 -
907275 907276 907277 M16 x 1,5 5,0 - 10,0 8,0 19 50 -
92667 92668 92669 M16 x 1,5 5,0 - 10,0 10,0 22 50 -
93910 93925 93939 M20 x 1,5 6,0 - 12,0 10,0 24 50 -
93911 93926 93940 M25 x 1,5 11,0 - 17,0 8,0 29 50 -
93912 93927 93941 M32 x 1,5 15,0 - 21,0 10,0 36 25 -
93913 93928 93942 M40 x 1,5 19,0 - 28,0 10,0 46 20 -
93914 93929 93943 M50 x 1,5 30,0 - 38,0 18,0 60 10 -
93915 93930 93944 M63 x 1,5 34,0 - 44,0 18,0 65 10 -

metric thread - with reducing seal


Part no. Part no. Part no. Size Cable Thread Spanner Unit
light grey dark grey black Metr. from / to length size
RAL 7035 RAL 7001 RAL 9005 mm mm mm
903532 903542 903552 M12 x 1,5 2,0 - 5,0 8,0 15 100 -
903533 903543 903553 M16 x 1,5 2,0 - 6,0 8,0 19 50 -
903534 903544 903554 M20 x 1,5 5,0 - 9,0 10,0 24 50 -
903535 903545 903555 M25 x 1,5 9,0 - 13,0 8,0 29 50 -
903536 903546 903556 M32 x 1,5 11,0 - 15,0 10,0 36 25 -
903537 903547 903557 M40 x 1,5 16,0 - 23,0 10,0 46 20 -
903538 903548 903558 M50 x 1,5 25,0 - 31,0 18,0 60 10 -
903539 903549 903559 M63 x 1,5 29,0 - 35,0 18,0 65 10 -

Continuation

944
Cable Glands / made of plastic for standard applications

HELUTOP HT cable gland


PG thread
Part no. Part no. Part no. Size Cable Thread Spanner Unit
light grey dark grey black PG from / to length size
RAL 7035 RAL 7001 RAL 9005 mm mm mm
99300 99310 99320 7 3,0 - 6,5 8,0 15 100 -
99301 99311 99321 9 4,0 - 8,0 8,0 19 50 -
99302 99312 99322 11 5,0 - 10,0 8,0 22 50 -
99303 99313 99323 13,5 6,0 - 12,0 9,0 24 50 -
99304 99314 99324 16 10,0 - 14,0 10,0 27 50 -
99305 99315 99325 21 13,0 - 18,0 11,0 33 25 -
99306 99316 99326 29 18,0 - 25,0 11,0 42 20 -
99307 99317 99327 36 22,0 - 32,0 13,0 53 10 -
99308 99318 99328 42 30,0 - 38,0 13,0 60 10 -
99309 99319 99329 48 34,0 - 44,0 14,0 65 10 -

NPT thread
Part no. Part no. Part no. Size Cable Thread Spanner Unit
light grey dark grey black NPT from / to length size
RAL 7035 RAL 7001 RAL 9005 mm mm mm
92780 92790 92800 3/8" 5,0 - 10,0 15,0 22 50 -
92781 92791 92801 1/2" 6,0 - 12,0 15,0 24 50 -
92782 92792 92802 1/2" 10,0 - 14,0 15,0 27 50 -
92783 92793 92803 3/4" 13,0 - 18,0 15,0 33 25 -
92784 92794 92804 1" 18,0 - 25,0 18,0 42 20 -

Dimensions and specifications may be changed without prior notice.

X
945
Cable Glands / made of brass for standard applications

HELUTOP HT-MS cable gland

HELUTOP HT-MS Material Technical data


The nickel-coated brass cable gland. Brass, nickel plated Protection class: IP 68 - 5 bar / IP 69K
Clamp: Polyamide PA 6
Application Seal: Chloroprene-rubber (CR) Temperature range: -40C up to +100C
Plant and machine construction O-ring: NBR
Robot construction Test standard: EN50262
Automation technology Properties
Vehicle construction and shipbuilding Optimum strain relief through clamping plates
Rail technology Easy to assemble
Installation technology Large clamping areas
Control cabinet construction
Note
Details on the individual tests appear in section
"Technical Information".

Dimensions
G Thread size
GL Thread length
SW Spanner size
metric thread
Part no. Size Cable Thread Spanner Unit
Metr. from / to length size
mm mm mm
90760 M12 x 1,5 3,0 - 6,5 6,0 14 50 -
99960 M16 x 1,5 5,0 - 10,0 7,0 20 50 -
90762 M20 x 1,5 6,0 - 12,0 8,0 22 50 -
99961 M25 x 1,5 11,0 - 17,0 8,0 27 25 -
94624 M32 x 1,5 15,0 - 21,0 8,0 34 20 -
99962 M40 x 1,5 19,0 - 28,0 9,0 43 5 -
99963 M50 x 1,5 30,0 - 38,0 9,0 58 5 -
90767 M63 x 1,5 34,0 - 44,0 14,0 64 / 68 5 -
906199 M63 x 1,5 44,0 - 55,0 10,0 75 5 -

metric thread - with reducing seal


Part no. Size Cable Thread Spanner Unit
Metr. from / to length size
mm mm mm
903560 M12 x 1,5 2,0 - 5,0 6,0 14 50 -
903561 M16 x 1,5 3,0 - 7,0 7,0 20 50 -
903562 M20 x 1,5 5,0 - 9,0 8,0 22 50 -
903563 M25 x 1,5 9,0 - 13,0 8,0 27 25 -
903564 M32 x 1,5 11,0 - 15,5 8,0 34 20 -
903565 M40 x 1,5 16,0 - 23,0 9,0 43 5 -
903566 M50 x 1,5 25,0 - 31,0 9,0 58 5 -
903567 M63 x 1,5 29,0 - 35,0 14,0 64 / 68 5 -

Continuation

946
Cable Glands / made of brass for standard applications

HELUTOP HT-MS cable gland


PG thread
Part no. Size Cable Thread Spanner Unit
PG from / to length size
mm mm mm
90750 7 3,0 - 6,5 5,0 14 50 -
90751 9 4,0 - 8,0 6,0 17 50 -
90752 11 5,0 - 10,0 6,0 20 50 -
90753 13,5 6,0 - 12,0 6,5 22 50 -
90754 16 10,0 - 14,0 6,5 24 25 -
90755 21 13,0 - 18,0 7,0 30 25 -
90756 29 18,0 - 25,0 8,0 40 20 -
90757 36 22,0 - 32,0 9,0 50 5 -
90758 42 32,0 - 38,0 14,0 58 5 -
90759 48 37,0 - 44,0 14,0 64 5 -

NPT thread
Part no. Size Cable Thread Spanner Unit
NPT from / to length size
mm mm mm
99965 3/8" 5,0 - 10,0 15,0 20 50 -
99966 1/2" 6,0 - 12,0 15,0 22 50 -
99967 3/4" 13,0 - 18,0 15,0 27 25 -
99968 1" 18,0 - 25,0 17,0 34 10 -

Dimensions and specifications may be changed without prior notice.

X
947
Cable Glands / for robust applications and special chemical resistance

HT-E cable gland


stainless steel

HELUTOP HT-E Material Technical data


The stainless steel cable gland for heavy load. Stainless steel 1.4305 / AISI 303 Protection class: IP 68 - 5 bar
Clamp: Polyamide PA 6
Application Seal: Chloroprene-rubber (CR) Temperature range: -40C up to +100C
Plant and machine construction O-ring: NBR
Robot construction Test standard: EN50262
Automation technology Properties
Vehicle construction and shipbuilding Optimum strain relief through clamping plates
Rail technology Highly corrosion-resistant
Installation technology Highly durable
Control cabinet construction Easy to assemble
Large clamping areas

Note
Details on the individual tests appear in section
"Technical Information". Dimensions
G Thread size
GL Thread length
SW Spanner size
metric thread
Part no. Size Cable Thread Spanner Unit
Metr. from / to length size
mm mm mm
99980 M12 x 1,5 3,0 - 6,5 6,0 14 50 -
99981 M16 x 1,5 5,0 - 10,0 7,0 22 50 -
99982 M20 x 1,5 6,0 - 12,0 8,0 22 50 -
99983 M25 x 1,5 11,0 - 17,0 8,0 27 25 -
99984 M32 x 1,5 15,0 - 21,0 8,0 36 25 -
99985 M40 x 1,5 19,0 - 28,0 9,0 46 20 -
99986 M50 x 1,5 30,0 - 38,0 9,0 60 12 -
99987 M63 x 1,5 34,0 - 44,0 14,0 65 / 68 12 -

PG thread
Part no. Size Cable Thread Spanner Unit
PG from / to length size
mm mm mm
99970 7 3,0 - 6,5 6,0 14 50 -
99971 9 4,0 - 8,0 6,0 17 50 -
99972 11 5,0 - 10,0 6,0 22 50 -
99973 13,5 6,0 - 12,0 6,5 22 50 -
99974 16 10,0 - 14,0 6,5 24 25 -
99975 21 13,0 - 18,0 7,2 30 25 -
99976 29 18,0 - 25,0 8,0 41 20 -
99977 36 22,0 - 32,0 9,0 50 15 -
99978 42 30,0 - 38,0 12,0 60 12 -
99979 48 34,0 - 44,0 14,0 65 12 -

NPT thread
Part no. Size Cable Thread Spanner Unit
NPT from / to length size
mm mm mm
99800 3/8" 5,0 - 10,0 11,5 20 50 -
99801 1/2" 6,0 - 12,0 13,0 22 50 -
99802 3/4" 13,0 - 18,0 13,0 30 25 -
99803 1" 18,0 - 25,0 13,0 40 / 43 10 -

Dimensions and specifications may be changed without prior notice.

948
Cable Glands / for electromagnetic compatibility (EMC)

HELUTOP MS-EP EMC cable gland

HELUTOP MS-EP Material Technical data


The EMC- and earthing gland with integrated Brass, nickel plated Protection class: IP 68 - 5 bar
contact system for safe, quick assembly and Contact system: Copper-Beryllium
contacting. Clamp: Polyamide PA 6 Temperature range: -40C up to +100C
Seal: Chloroprene-rubber (CR)
Application O-ring: NBR Test standard: EN50262
Plant and machine construction
Robot construction Properties Contact system: patented
Automation technology Optimum strain relief through clamping plates
Vehicle construction and shipbuilding No damage of shield during assembly or
Rail technology disassembly by moving contact ring
Installation technology Contact made automatically when the gland
Control cabinet construction is closed
Excellent shield damping and current
deflection
High savings achieved in time and assembly
costs
Dimensions
Note G Thread size
Details on the individual tests appear in section GL Thread length
"Technical Information". SW Spanner size
metric thread
Part no. Size Cable Thread Spanner Unit
Metr. from / to length size
mm mm mm
99950 M12 x 1,5 3,0 - 6,5 6,0 14 50 -
99951 M16 x 1,5 5,0 - 10,0 7,0 20 50 -
99952 M20 x 1,5 6,0 - 12,0 8,0 22 50 -
99953 M25 x 1,5 11,0 - 17,0 8,0 27 25 -
99954 M32 x 1,5 15,0 - 21,0 8,0 34 25 -
99955 M40 x 1,5 19,0 - 28,0 9,0 43 20 -
99956 M50 x 1,5 27,0 - 38,0 9,0 58 5 -
99957 M63 x 1,5 34,0 - 44,0 14,0 64 / 68 5 -

Dimensions and specifications may be changed without prior notice.

X
949
Cable Glands / for electromagnetic compatibility (EMC)

HELUTOP MS-EP4 EMC cable gland

HELUTOP MS-EP4 Material Technical data


The EMC- cable gland with integrated contact Brass, nickel plated Protection class: IP 68 - 5 bar
system. Contact system: Copper-Beryllium
Clamp: Polyamide PA 6 Temperature range: -40C up to +100C
Application Seal: Chloroprene-rubber (CR)
Plant and machine construction O-ring: NBR Contact system: patented
Robot construction
Automation technology Properties
Vehicle construction and shipbuilding Easy installation
Rail technology Secure contact
Installation technology High vibration resistance
Control cabinet construction
Note
Details on the individual tests appear in section
"Technical Information".
Dimensions
G Thread size
GL Thread length
SW Spanner size
metric thread
Part no. Size Cable Thread Spanner Unit
Metr. from / to length size
mm mm mm
905181 M12 x 1,5 3,0 - 6,5 6,0 14 50 -
905182 M16 x 1,5 5,0 - 10,0 6,0 20 50 -
905183 M20 x 1,5 6,0 - 12,0 6,0 22 50 -
905184 M20 x 1,5 7,5 - 14,0 8,0 24 50 -
905185 M25 x 1,5 10,0 - 18,0 8,0 30 25 -
905186 M32 x 1,5 16,0 - 25,0 9,0 40 20 -
905187 M40 x 1,5 22,0 - 32,0 9,0 50 20 -
905188 M50 x 1,5 30,0 - 38,0 9,0 58 10 -
905189 M63 x 1,5 34,0 - 44,0 14,0 64 / 68 5 -
905248 M63 x 1,5 37,0 - 53,0 10,0 75 5 -

Dimensions and specif

You might also like