2015 - CW Catalogue Cables and Wires A4 En-2
2015 - CW Catalogue Cables and Wires A4 En-2
2015 - CW Catalogue Cables and Wires A4 En-2
helukabel.co.uk
I1T5ODUCTIO1
With our new main catalog "Cables & Wires" you are holding in
your hands a version that has been revised in visual presentation
as well as in content. Our objective was and is to guide you more
quickly to your desired product. The tabular overviews that
precede each product chapter should help in this regard.
Futhermore, we have developed additional selection tables that
facilitate navigation between the chapters.
We are proud of the fact that in the areas of industrial and
infrastructure cables we are uniformly well-positioned with high
in-stock availability. True to our motto, "All from One Source", in
addition to the "Data, network & BUS technology" section, we also
included a selection of accessory products in the main catalog for
the rst time. 1ew products created since our last catalog are
placed in their respective chapters.
In cases where more than 33,000 standard products are not
enough to nd the right cable product for a unique application
our engineers are at your side to develop both a technically and
economically superior solution. Your advancement is our driving
force!
Helmut Luksch
&JKGH(ZGEWVKXG2HEGT+(/8.$%(/*OD+
1
HELUKABEL AT A *LA1CE
FAMILY FOCUSED
Family enterprise since 1978
GLOBAL PRODUCTION
41 locations in 24 countries 6 manufacturing and
assembly locations
worldwide
LOGISTICS PRODUCTS
33,000 products in stock, from Cables, wires and cable accessories
the cable gland to the 2.40 m - single-source supplier for
cable drum industry and infrastructure
24 h delivery service
State-of-the-art logistics
facility
2
TABLE OF CO1TE1TS
INTRODUCTION .................................................................................................................................................................. 1
5esearch & development ....................................................................................................................................................... 4
Production ............................................................................................................................................................................ 6
Logistics ................................................................................................................................................................................ 8
Success through quality and innovation ................................................................................................................................. 10
Our branded products ........................................................................................................................................................... 12
Always close to you - 41 locations in 24 countries ................................................................................................................. 14
5obotec Systems ................................................................................................................................................................... 16
Kabelmat Wickeltechnik ........................................................................................................................................................ 18
Chapter overview .................................................................................................................................................................. 20
3
4
5ESEA5CH & DE9ELOP0E1T
5esearch and development are the foun- high-quality product relative to properties
dation of our work and are an important and workmanship.
engine for growth. In interdisciplinary With continuous optimization of our
teams we continuously push the manufacturing processes and systems
boundaries to enhance our products and we take into consideration both efcient
develop solutions to meet the latest and economical production, and the
technological demands. 0oreover, we complex requirements of various
value our customer interactions and applications (such as cables for industrial
partnerships with regional colleges and robots or for applications under
research institutes to stay on top of cleanroom conditions) into account.
emerging technologies.
A crucial stage in the development
The materials that we use are an process of our products is the work done
important starting point of our work. In at our Test Center. For example, cables
this regard, we place as much emphasis suitable for drag chain implementation,
on searching for and utilizing new can be tested using equipment that
Torsion test apparatus materials, as we do on manufacturing accelerates cables up to 10 g.
our plastic mixtures (granulates) our- Temperature ranges from -50 to +250
selves, and inuencing the improvement are simulated in a special climate-
of technical characteristics, such as controlled environment so that drag
Our test facilities:
oil-resistance, temperature range or chain cables can be tested for series
chemical compatibility. 0oreover, we are production readiness in applications such
Test systems for bending and
capable of pulling a majority of the as refrigerated warehouses or steel mills.
torsion requirements
copper ourselves, thus ensuring a uniform,
5
|6
P5ODUCTIO1
We specialize in the production of high-quality cables and wires.
Using the latest production methods, our two German plants Since 2014, in a 7,000 m facility in the Chinese city of Taicang
manufacture approximately one million kilometers of conductors (approx. 50 km northwest of Shanghai) HELUKABEL has been
each year ( 77 times around the world). 0ore than 300 producing cable and wires, primarily for the Asian market. As is
qualied employees are specialized in the production of with our German plants, the focus is on high-quality, exible and
high-quality standard and custom cables. Through the use of the highly-exible cables and wires that are manufactured in
latest materials and collaboration with international test accordance with Chinese and international standards. The use of
institutes, we drive innovation in the areas of automation, data exible manufacturing cells enable short delivery times.
technology, building system technology, and renewable energy.
7
8
LOGISTICS
5edening logistics in the cable industry.
9
10
SUCCESS THROUGH QUALITY AND INNOVATION
Quality and environmental principles
HELUKABEL GmbH is an independent enterprise that requirements, as well as corporate environmental protection.
manufactures and sells cables, wires, and accessories. Our standard is customer satisfaction and trust. Indicators of
HELUKABEL
has a high commitment to quality and the this are the economic success of the enterprise and long-stand-
environment. For this reason the executive board has ing customer relationships.
introduced an integrated management system for quality Fulllment of our quality and environmental principles is an
and the environment based on DIN EN ISO 9001:2008 and obligation and ongoing task of the executive board and each
DIN EN ISO 14001:2009 standards. individual employee. Our high standards are expressed in the
HELUKABEL GmbH's quality and environmental policy is following criteria:
oriented to meet market needs and fulll customer
Environment Employees
Environmental protection in the enterprise is a Qualied employees who work
principle of our work and is not only oriented cooperatively in teams and combine a high
to comply with legal requirements, but rather level of individual responsibility and autonomy
to avoid or minimize pollution and its effects with a marked awareness of quality and the
on the environment. environment ensure the success of the
management system at HELUKABEL GmbH.
Quality Suppliers
Reliable products that meet the Develop partnerships with suppliers
specications to satisfy customer who will work together with us to
requirements. satisfy our quality and environmental
standards.
Objectives Conduct
Products complying with require- Cost awareness and environmental
ments and timely order processing, awareness are maintained by
whereby environmental impact is every employee to satisfy customer
avoided or kept to a minimum. requirements, while maintaining the
ability to react effectively to changing
circumstances.
The integrated quality and environmental management system supports the success factors of HELUKABEL GmbH and documents
how we work; this is described in the management manual, which is binding for all employees.
11
04 | 12
OUR BRANDED PRODUCTS
Cables & wires
BIOFLEX-500 bio-oil resistant cables
CLEANFLEX cleanroom data and control cables
DATAFLA00 data and computer cables, halogen free
DATAPUR-C data and computer cables
GALVANICABLE high-voltage cathode cable
HELUFLON heat-resistant cables
HELUTHER0 heat-resistant cables
HELUTRAIN train cables
HELUTRUCK vehicle cables/truck cables
HELUWIND wind power cables
KO0POFLEX microbe-resistant cables
KO0POSPEED bio-oil resistant drag chain cables
LIFT-TRAGO elevator control cables
0EGAFLEX exible control cables, halogen free, UL/CSA
0ULTIFLEX 512 PUR drag chain cables
0ULTISPEED drag chain cables
NANOFLEX PUR special control and data cables
ROBOFLEX robot cables
SENSORFLEX sensor cables
SHIPFLEX drag chain cables
SOLARFLEX photovoltaic cables
SUPER-PAAR-TRONIC-C-PUR drag chain cables, halogen free
SUPERTRONIC drag chain cables
THER0FLEX heat-resistant cables
TOPFLEX servo, feedback and motor cables
TOPSERV servo, feedback and motor cables
TRAYCONTROL exposed run cable
TRO00PUR easy-to-wind cables
UNIPUR PUR, exible control cables
Cable accessories
HELUCHAIN drag chain product line
HELUTEC industrial connector series
HELUTOP cable gland product line
0edia technology
HELUEVENT high-powered cable for TV studios
HELULIGHT cables for lighting control systems
HELUSOUND audio cable
13
ALWAYS CLOSE TO YOU - 41 LOCATIONS IN 24 COUNTRIES
Headquarters
Dieselstrasse 8-12
71282 Hemmingen / Stuttgart
Telephone: +49 7150 9209-0
Fax +49 7150 81786
[email protected]
14
HELUKABEL international locations
15
ROBOTEC SYSTE0S - UN0ATCHED ROBOTIC CO0PETENCE
Since its founding in 1998, Robotec and ready to install. From the development
Systems GmbH, headquartered in Kamp- of various design concepts to prototyping,
Lintfort, Germany, has become one of the to nal installation and on-site service,
leading European companies for robot Robotec is a single source for all robotic
hose packages and associated fastening services.
systems as well as for custom robot Through the use of rst-class components,
Concept
cables, cable assemblies, power screw- as well as superstructures and material
driver technology, controllers for meas- compositions tailored for the respective
urement instrumentation and media application, the highest level of reliability
systems such as air hoses and water hoses. and productivity is achieved.
The company has been a 100% Robotec's products are used in applications,
subsidiary of HELUKABEL GmbH since such as spot, laser and inert gas welding,
July 2012. robot handling, and tool changing
Robotec Systems develops tailored energy- systems. Development
Prototyping
Our components:
Documentation
+GFQHEG %TPEJQHEGm6QWVJ
Robotec Systems GmbH Robotec Systems GmbH
Carl-Friedrich-Gau-Strasse 7 Willi-Bleicher-Strasse 4-6
47475 Kamp-Lintfort, Germany 71282 Hemmingen
Telephone: +49 (0)2842 92148-0 Telephone: +49 (0)7150 9209-308
Fax: +49 (0)2842 92148-10 Fax: +49 (0)7150 9209-164
www.robotec-systems.de www.robotec-systems.de
[email protected] [email protected]
Repair/maintenance
17
18
KABEL0AT WICKELTECHNIK G0BH
Kabelmat Wickeltechnik GmbH's history goes back to the 1960s
and since then the company has been among the market leaders for
winding systems in the cable and wire industry.
Customers include manufacturers, retailers, cable and wire
processors, as well as cable assemblers, electricians, machine
manufacturing companies, and many more.
The product range includes virtually all devices and machines for
storing, winding and cutting cables, wires, rope, tubes, hoses, and
proles.
Winding from and onto drums, as well as from drums to rings are
among the tasks that are efciently executed worldwide with
Kabelmat products.
We would be pleased to show you our products in our showroom.
You are cordially invited to visit us at our facility.
0ESSBOI 40
19
CHAPTER OVERVIEW
INDUSTRIAL CABLES & WIRES
Heat-resistant cables
218 - 237 Compensating cables
Trailing cables
252 - 259 Cables according to
International Approvals
with international approvals
348 - 511
G 483 N
20
INFRASTRUCTURE CABLES & WIRES MEDIA TECHNOLOGY
7GNGRJQPG TGYTPKPIEDNGU
522 - 533
P
RENEWABLE ENERGY & TRANSPORTATION
&DNGUHQTYKPFVWTDKPGU
802 - 821
T
DATA, NETWORK & BUS TECHNOLOGY
Cables for
Fiber optic cables
aircraft supply
604 - 651
822 - 825
R T
21
CHAPTER OVERVIEW
PRE-ASSEMBLED CABLES CABLE ACCESSORIES
Cable ties
980 - 985
X
SPIRAL CABLES
Tools
1002 - 1017
X
918 - 939
W
22
TECHNICAL INFORMATION
Technical information
1018 - 1172
Y
23
Table of contents
04 | 24
INDUSTRIAL CABLES & WIRES
25
FLEXIBLE CONTROL CABLES A
3
in
E
VD eld 29
ng
x
xe
ex
VD
ed
U
R/ shi E 0
xi
- fi
- fl
./
0 /
le
ed
i
no
H A ed / VD
-f
-f
U
C)
C)
ge
us
us
CS REG
e n es /
(
e
lta
di
di
se
re
re
t
fre
ut tan
r
n
ra
ra
co
tu
tu
u
vo
E
ai
n-
or
sis
ra
ra
A
d
ch
al
ge
in
in
pe
pe
re
do
re
in
ge
nd
nd
ag
lo
lo
re
V-
m
L/
om
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
N
PVC control cables
H05 BQ-F / H07 BQ-F (NGMH11Y) -40 to +80 -50 to +90 300/500 5x 3x X X X X 72
27
FLEXIBLE CONTROL CABLES
3
in
E
VD eld 29
ng
x
ge
xe
ex
VD
vo U
R/ shi E 0
xi
lta
ak 0 /
- fi
- fl
./
fle
ix
pe U
ed
no
H A ed / VD
-f
C)
C)
g ge
s-
us
CS REG
e n es /
(
tin lta
e
di
di
se
re
re
t
re
n
ra vo
r
n
ra
ra
co
tu
tu
u
f
E
ai
n-
t
pe l
or
sis
ra
ra
g
O ina
A
d
ch
ge
in
in
pe
pe
re
do
re
ge
om
nd
nd
ag
lo
lo
re
V-
m
L/
ut
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
Halogen-free control cables
MEGAFLEX 500
-30 to +80 -40 to +80 300/500 10x 4x X X X X 88
MEGAFLEX 500-C
-30 to +80 -40 to +80 300/500 10x 4x X X X X X 98
JZ-600 HMH-C -15 to +70 -40 to +70 0.6/1 kV 15x 7.5x X X X 100
BIOFLEX-500 -JZ-C
-20 to +80 -40 to +80 300/500 20x 6x X X 110
KOMPOFLEX JZ-500-C
-30 to +90 -40 to +100 300/500 7.5x 4x X X X X 113
Hygienic cable
NANOFLEX HC*TRONIC
-5 to +80 -40 to +80 350 7.5x 4x X X X X 118
28
PVC CONTROL CABLES
Flexible Control Cables / PVC Control Cables
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, as measuring and control cables in tool machines, conveyor belts, production lines in machinery production,
in air-conditioning and in steel production.
Selected PVC-compounds guarantee a good flexibility as well as an economic and fast installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10001 2 x 0,5 4,8 9,6 40,0 20 10025 50 G 0,5 17,5 240,0 513,0 20
10002 3 G 0,5 5,1 14,4 46,0 20 10169 52 G 0,5 17,5 252,0 534,0 20
10003 3 x 0,5 5,1 14,4 46,0 20 10026 61 G 0,5 18,5 293,0 625,0 20
10004 4 G 0,5 5,5 19,0 56,0 20 10027 65 G 0,5 19,4 312,0 682,0 20
10005 4 x 0,5 5,5 19,0 56,0 20 10028 80 G 0,5 21,4 384,0 780,0 20
10006 5 G 0,5 6,2 24,0 65,0 20 10029 100 G 0,5 24,0 480,0 980,0 20
10007 5 x 0,5 6,2 24,0 65,0 20 10030 2 x 0,75 5,3 14,4 46,0 19
10008 6 G 0,5 6,7 29,0 75,0 20 10031 3 G 0,75 5,6 21,6 54,0 19
10009 7 G 0,5 6,7 33,6 80,0 20 10032 3 x 0,75 5,6 21,6 54,0 19
10010 7 x 0,5 6,7 33,6 80,0 20 10033 4 G 0,75 6,3 28,8 66,0 19
10011 8 G 0,5 7,4 38,0 97,0 20 10034 4 x 0,75 6,3 29,0 66,0 19
10172 8 x 0,5 7,4 38,0 97,0 20 10035 5 G 0,75 6,9 36,0 80,0 19
10012 10 G 0,5 8,3 48,0 116,0 20 10036 5 x 0,75 6,9 36,0 80,0 19
10013 12 G 0,5 8,7 58,0 135,0 20 10037 6 G 0,75 7,5 43,0 99,0 19
10014 12 x 0,5 8,7 58,0 135,0 20 10177 6 x 0,75 7,5 43,0 99,0 19
10015 14 G 0,5 9,5 67,0 150,0 20 10038 7 G 0,75 7,5 50,0 110,0 19
10183 16 G 0,5 10,0 76,0 175,0 20 10039 7 x 0,75 7,5 50,0 110,0 19
10016 18 G 0,5 10,7 86,0 196,0 20 10040 8 G 0,75 8,3 58,0 130,0 19
10017 20 G 0,5 11,3 96,0 215,0 20 10173 8 x 0,75 8,3 58,0 130,0 19
10018 21 G 0,5 11,3 101,0 240,0 20 10041 9 G 0,75 8,9 65,0 153,0 19
10019 25 G 0,5 12,6 120,0 270,0 20 10042 10 G 0,75 9,2 72,0 162,0 19
10020 30 G 0,5 13,5 144,0 310,0 20 10043 12 G 0,75 9,8 86,0 179,0 19
10021 32 G 0,5 14,0 154,0 323,0 20 10044 12 x 0,75 9,8 86,0 179,0 19
10022 34 G 0,5 14,3 163,0 362,0 20 10045 14 G 0,75 10,6 101,0 214,0 19
10023 40 G 0,5 15,3 192,0 434,0 20 10046 15 G 0,75 11,4 108,0 218,0 19
10024 42 G 0,5 15,8 202,0 449,0 20 10047 18 G 0,75 12,2 130,0 257,0 19
Continuation
30
Flexible Control Cables / PVC Control Cables
31
Flexible Control Cables / PVC Control Cables
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms and in open air. Must not be laid directly in soil or water. When screened for measurement, control and control line etc. in mechanical
and plant engineering, machine tools, production lines and conveyor belts.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10340 2 x 0,5 5,4 9,6 40,0 20 10363 25 G 1 16,2 240,0 485,0 18
10341 3 G 0,5 5,7 14,4 46,0 20 10543 34 G 1 18,7 326,0 690,0 18
11630 3 x 0,5 5,7 14,4 46,0 20 10364 2 x 1,5 7,0 29,0 70,0 16
10342 4 G 0,5 6,1 19,0 56,0 20 10365 3 G 1,5 7,4 43,0 90,0 16
11631 4 x 0,5 6,1 19,0 56,0 20 11645 3 x 1,5 7,4 43,0 90,0 16
10343 5 G 0,5 6,8 24,0 65,0 20 10366 4 G 1,5 8,2 58,0 109,0 16
11632 5 x 0,5 6,8 24,0 65,0 20 11646 4 x 1,5 8,2 58,0 109,0 16
10344 7 G 0,5 7,3 33,6 80,0 20 10367 5 G 1,5 9,1 72,0 131,0 16
11633 7 x 0,5 7,3 33,6 80,0 20 11647 5 x 1,5 9,1 72,0 131,0 16
10345 12 G 0,5 9,6 58,0 135,0 20 10368 7 G 1,5 9,8 101,0 184,0 16
11634 12 x 0,5 9,6 58,0 135,0 20 11648 7 x 1,5 9,8 101,0 184,0 16
10346 18 G 0,5 11,5 86,0 196,0 20 10369 12 G 1,5 13,2 173,0 309,0 16
10347 25 G 0,5 13,5 120,0 270,0 20 11649 12 x 1,5 13,2 173,0 309,0 16
10348 2 x 0,75 5,9 14,4 46,0 19 10370 18 G 1,5 15,6 259,0 440,0 16
10349 3 G 0,75 6,2 21,6 54,0 19 10371 25 G 1,5 18,6 360,0 620,0 16
11635 3 x 0,75 6,2 21,6 54,0 19 10372 2 x 2,5 8,4 48,0 112,0 14
10350 4 G 0,75 6,7 28,8 66,0 19 10373 3 G 2,5 8,9 72,0 148,0 14
11636 4 x 0,75 6,7 28,8 66,0 19 11650 3 x 2,5 8,9 72,0 148,0 14
10351 5 G 0,75 7,5 36,0 80,0 19 10374 4 G 2,5 9,8 96,0 178,0 14
11637 5 x 0,75 7,5 36,0 80,0 19 11651 4 x 2,5 9,8 96,0 178,0 14
10352 7 G 0,75 8,3 50,0 110,0 19 10375 5 G 2,5 10,9 120,0 221,0 14
11638 7 x 0,75 8,3 50,0 110,0 19 11652 5 x 2,5 10,9 120,0 221,0 14
10353 12 G 0,75 10,8 86,0 179,0 19 10376 7 G 2,5 12,0 168,0 306,0 14
11639 12 x 0,75 10,8 86,0 179,0 19 11653 7 x 2,5 12,0 168,0 306,0 14
10354 18 G 0,75 12,8 130,0 257,0 19 10377 12 G 2,5 15,9 288,0 498,0 14
10355 25 G 0,75 15,1 180,0 365,0 19 11654 12 x 2,5 15,9 288,0 498,0 14
10356 2x1 6,2 19,2 60,0 18 10378 18 G 2,5 19,0 432,0 764,0 14
10357 3G1 6,5 29,0 72,0 18 10379 25 G 2,5 22,6 600,0 1044,0 14
11640 3x1 6,5 29,0 72,0 18 10380 4G4 11,5 154,0 295,0 12
10358 4G1 7,2 38,4 86,0 18 10381 5G4 12,8 192,0 361,0 12
11641 4x1 7,2 38,4 86,0 18 10382 4G6 13,6 230,0 424,0 10
10359 5G1 8,1 48,0 104,0 18 10383 5G6 15,1 288,0 525,0 10
11642 5x1 8,1 48,0 104,0 18 10384 4 G 10 17,1 384,0 701,0 8
10360 7G1 8,7 67,0 141,0 18 10388 5 G 10 18,9 480,0 909,0 8
11643 7x1 8,7 67,0 141,0 18 10385 4 G 16 20,9 614,0 1035,0 6
10361 12 G 1 11,4 115,0 230,0 18 10386 4 G 25 25,6 960,0 1582,0 4
11644 12 x 1 11,4 115,0 230,0 18 10387 4 G 35 29,4 1344,0 2105,0 2
10362 18 G 1 13,7 173,0 343,0 18
32
Flexible Control Cables / PVC Control Cables
JZ-500 orange flexible, orange cores, control cable for interlocking purposes,
meter marking
A
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, as control cable acc. to EN 60204 part 1 and VDE 0113 part 1. As per recommendation of the specified
standards the insulated conductors of control current circuits should be coloured orange, when they are used for interlocking purposes. These control
circuits are supplied with an external power and remain active under current when the main switch is disconnected or switched off.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10537 2x1 5,6 19,2 60,0 18 10546 4 G 1,5 7,4 58,0 109,0 16
10538 3G1 5,9 29,0 72,0 18 10547 5 G 1,5 8,3 72,0 131,0 16
10539 3x1 5,9 29,0 72,0 18 10747 3 G 2,5 8,3 72,0 148,0 14
10541 4x1 6,6 38,4 86,0 18 10748 4 G 2,5 9,2 96,0 178,0 14
10540 4G1 6,6 38,4 86,0 18 10749 5 G 2,5 10,1 120,0 221,0 14
10542 5G1 7,3 48,0 104,0 18
10544 2 x 1,5 6,4 29,0 70,0 16
10545 3 G 1,5 6,8 43,0 90,0 16
33
Flexible Control Cables / PVC Control Cables
Application
This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced
motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production
streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient
and fast installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10750 2 x 0,5 4,8 9,6 40,0 20 10774 2 x 1,5 6,4 29,0 70,0 16
10751 3 G 0,75 5,6 21,6 54,0 19 10775 3 G 1,5 6,8 43,0 90,0 16
10752 3 x 0,75 5,6 21,6 54,0 19 10776 3 x 1,5 6,8 43,0 90,0 16
10753 4 G 0,75 6,3 28,8 66,0 19 10777 4 G 1,5 7,4 58,0 109,0 16
10754 4 x 0,75 6,3 29,0 66,0 19 10778 4 x 1,5 7,4 58,0 109,0 16
10755 5 G 0,75 6,9 36,0 80,0 19 10779 5 G 1,5 8,3 72,0 131,0 16
10756 5 x 0,75 6,9 36,0 80,0 19 10780 5 x 1,5 8,3 72,0 131,0 16
10757 7 G 0,75 7,5 50,0 110,0 19 10781 6 G 1,5 9,2 86,0 157,0 16
10758 7 x 0,75 7,5 50,0 110,0 19 10782 7 G 1,5 9,2 101,0 184,0 16
10759 12 G 0,75 9,8 86,0 179,0 19 10783 7 x 1,5 9,2 101,0 184,0 16
10760 18 G 0,75 12,2 130,0 257,0 19 10784 12 G 1,5 11,8 173,0 309,0 16
10761 25 G 0,75 14,3 180,0 365,0 19 10785 18 G 1,5 14,6 259,0 440,0 16
10762 2x1 5,6 19,2 60,0 18 10786 25 G 1,5 17,4 360,0 620,0 16
10763 3G1 5,9 29,0 72,0 18 10787 2 x 2,5 7,8 48,0 112,0 14
10764 3x1 5,9 29,0 72,0 18 10788 3 G 2,5 8,3 72,0 148,0 14
10765 4G1 6,6 38,4 86,0 18 10789 3 x 2,5 8,3 72,0 148,0 14
10766 4x1 6,6 38,4 86,0 18 10790 4 G 2,5 9,2 96,0 178,0 14
10767 5G1 7,3 48,0 104,0 18 10791 4 x 2,5 9,2 96,0 178,0 14
10768 5x1 7,3 48,0 104,0 18 10792 5 G 2,5 10,1 120,0 221,0 14
10769 7G1 8,1 67,0 141,0 18 10793 5 x 2,5 10,1 120,0 221,0 14
10770 7x1 8,1 67,0 141,0 18 10794 7 G 2,5 11,2 168,0 306,0 14
10771 12 G 1 10,4 115,0 230,0 18 10795 7 x 2,5 11,2 168,0 306,0 14
10772 18 G 1 12,9 173,0 343,0 18 10796 4G6 13,0 230,0 424,0 10
10773 25 G 1 15,4 240,0 485,0 18 10797 5G6 14,5 288,0 525,0 10
34
Flexible Control Cables / PVC Control Cables
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and
production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants
and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13122 2 x 0,5 5,2 - 6,6 9,7 46,0 20 13123 2 x 0,75 5,7 - 7,2 14,1 52,0 19
13001 3 G 0,5 5,5 - 7,0 14,4 54,0 20 13013 3 G 0,75 6,0 - 7,6 21,6 68,0 19
13002 4 G 0,5 6,2 - 7,9 19,0 65,0 20 13014 4 G 0,75 6,6 - 8,3 29,0 82,0 19
13003 5 G 0,5 6,8 - 8,6 24,0 80,0 20 13015 5 G 0,75 7,4 - 9,3 36,0 107,0 19
13004 6 G 0,5 7,6 - 9,6 29,0 104,0 20 13016 6 G 0,75 8,1 - 10,1 43,0 132,0 19
13005 7 G 0,5 8,3 - 10,4 33,6 119,0 20 13017 7 G 0,75 9,0 - 11,3 50,0 145,0 19
13920 8 G 0,5 9,2 - 11,5 38,0 134,0 20 13926 8 G 0,75 9,9 - 12,3 58,0 189,0 19
13006 9 G 0,5 10,1 - 12,5 43,0 136,0 20 13018 9 G 0,75 10,6 - 13,2 65,0 194,0 19
13921 10 G 0,5 10,9 - 13,6 48,0 166,0 20 13019 12 G 0,75 11,0 - 13,7 86,0 231,0 19
13007 12 G 0,5 10,4 - 12,9 58,0 186,0 20 13927 14 G 0,75 11,7 - 14,5 101,0 274,0 19
13922 14 G 0,5 10,9 - 13,6 67,0 215,0 20 13020 18 G 0,75 13,2 - 16,4 130,0 313,0 19
13008 18 G 0,5 12,3 - 15,3 86,0 251,0 20 13021 25 G 0,75 15,8 - 19,5 180,0 461,0 19
13009 25 G 0,5 14,8 - 18,2 120,0 349,0 20 13928 27 G 0,75 16,2 - 19,9 195,0 493,0 19
13923 27 G 0,5 15,1 - 18,6 129,6 373,0 20 13022 34 G 0,75 18,4 - 22,6 245,0 614,0 19
13010 34 G 0,5 17,2 - 21,2 163,0 480,0 20 13929 36 G 0,75 18,2 - 22,4 259,0 646,0 19
13924 36 G 0,5 17,0 - 20,9 172,0 510,0 20 13126 41 G 0,75 20,1 - 24,6 295,0 730,0 19
13125 41 G 0,5 18,8 - 23,1 196,0 570,0 20 13023 50 G 0,75 21,9 - 26,8 360,0 896,0 19
13011 50 G 0,5 20,5 - 25,2 240,0 658,0 20 13024 61 G 0,75 23,4 - 28,7 439,0 1030,0 19
13012 61 G 0,5 22,0 - 26,9 293,0 780,0 20 13930 65 G 0,75 24,4 - 29,8 468,0 1071,0 19
13925 65 G 0,5 22,8 - 28,0 312,0 810,0 20
Continuation
35
Flexible Control Cables / PVC Control Cables
36
Flexible Control Cables / PVC Control Cables
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and
production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants
and car washing stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
13133 2x4 10,7 77,0 195,0 12 13153 3 G 16 18,8 461,0 827,0 6
13134 3G4 11,3 115,0 230,0 12 13154 4 G 16 20,9 614,0 1035,0 6
13135 4G4 12,4 154,0 295,0 12 13155 5 G 16 23,4 768,0 1259,0 6
13136 5G4 13,9 192,0 361,0 12 13156 7 G 16 28,5 1075,0 1780,0 6
13138 7G4 16,6 269,0 466,0 12 13159 4 G 25 26,3 960,0 1582,0 4
13141 12 G 4 20,8 461,0 810,0 12 13160 5 G 25 29,5 1200,0 1852,0 4
13142 2x6 12,0 116,0 280,0 10 13161 3 G 35 26,5 1008,0 1614,0 2
13143 3G6 12,9 173,0 358,0 10 13162 4 G 35 29,5 1344,0 2110,0 2
13144 4G6 14,2 230,0 424,0 10 13163 5 G 35 32,8 1680,0 2652,0 2
13145 5G6 15,9 288,0 525,0 10 13164 3 G 50 32,2 1440,0 2560,0 1
13146 7G6 18,9 403,0 625,0 10 13165 4 G 50 36,1 1920,0 2972,0 1
13148 3 G 10 16,3 288,0 540,0 8 13166 5 G 50 40,3 2400,0 3948,0 1
13149 4 G 10 18,1 384,0 701,0 8
13150 5 G 10 20,3 480,0 858,0 8
13151 7 G 10 24,3 672,0 1106,0 8
37
Flexible Control Cables / PVC Control Cables
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, wherever internationally recognized PVC cables are required. E. g. as a control or measurements cable
on industrial machinery, on conveyor systems or in industrial plants, etc. The number coding has been brought onto the cores in such a way that it is
easily identifiable and the core numbers are individually underlined to avoid confusion. The green-yellow earth core is laid in the outer layer.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10800 2 x 0,5 5,7 9,6 48,0 20 10834 3G1 7,0 29,0 92,0 18
10801 3 G 0,5 6,0 14,5 65,0 20 10835 3x1 7,0 29,0 92,0 18
10802 4 G 0,5 6,8 20,0 81,0 20 10836 4G1 7,8 39,0 122,0 18
10803 5 G 0,5 7,4 24,0 98,0 20 10837 4x1 7,8 39,0 122,0 18
10804 7 G 0,5 8,3 34,0 123,0 20 10838 5G1 8,6 48,0 137,0 18
10805 8 G 0,5 9,1 38,0 155,0 20 10839 7G1 9,5 68,0 186,0 18
10806 10 G 0,5 10,0 48,0 180,0 20 10840 7x1 9,5 68,0 186,0 18
10807 12 G 0,5 10,8 58,0 208,0 20 10841 8G1 10,3 77,0 240,0 18
10808 14 G 0,5 11,7 67,0 248,0 20 10842 12 G 1 12,7 116,0 293,0 18
10809 16 G 0,5 12,5 76,0 260,0 20 10843 14 G 1 13,4 134,0 340,0 18
10810 18 G 0,5 13,2 87,0 285,0 20 10844 16 G 1 14,4 154,0 400,0 18
10811 21 G 0,5 13,8 96,0 375,0 20 10845 18 G 1 15,1 173,0 437,0 18
10812 25 G 0,5 15,5 118,0 400,0 20 10846 21 G 1 16,1 205,0 505,0 18
10813 30 G 0,5 16,6 144,0 475,0 20 10847 25 G 1 18,0 240,0 606,0 18
10814 40 G 0,5 18,7 192,0 590,0 20 10848 34 G 1 20,9 326,0 770,0 18
10815 50 G 0,5 21,5 240,0 710,0 20 10849 41 G 1 22,6 394,0 880,0 18
10816 61 G 0,5 23,0 293,0 880,0 20 10850 50 G 1 24,8 480,0 1400,0 18
10817 2 x 0,75 6,2 15,0 60,0 19 10851 61 G 1 26,5 586,0 1450,0 18
10818 3 G 0,75 6,5 22,0 78,0 19 10852 2 x 1,5 7,2 29,0 90,0 16
10819 4 G 0,75 7,3 29,0 104,0 19 10853 3 G 1,5 7,8 43,0 120,0 16
10820 5 G 0,75 8,0 36,0 116,0 19 10854 3 x 1,5 7,8 43,0 120,0 16
10821 7 G 0,75 8,9 51,0 148,0 19 10855 4 G 1,5 8,5 58,0 150,0 16
10822 8 G 0,75 9,6 58,0 160,0 19 10856 4 x 1,5 8,5 58,0 155,0 16
10823 10 G 0,75 10,7 72,0 195,0 19 10857 5 G 1,5 9,6 72,0 177,0 16
10824 12 G 0,75 11,6 87,0 248,0 19 10858 7 G 1,5 10,4 101,0 220,0 16
10825 15 G 0,75 13,2 108,0 295,0 19 10859 8 G 1,5 11,4 115,0 248,0 16
10826 18 G 0,75 14,1 130,0 346,0 19 10860 9 G 1,5 12,5 130,0 278,0 16
10827 21 G 0,75 14,8 151,0 395,0 19 10861 12 G 1,5 14,1 173,0 364,0 16
10828 25 G 0,75 16,6 180,0 505,0 19 10862 14 G 1,5 14,9 202,0 390,0 16
10829 34 G 0,75 19,3 245,0 684,0 19 10863 16 G 1,5 16,0 230,0 490,0 16
10830 41 G 0,75 20,9 296,0 780,0 19 10864 18 G 1,5 17,0 259,0 550,0 16
10831 50 G 0,75 22,9 360,0 940,0 19 10865 21 G 1,5 18,0 302,0 670,0 16
10832 61 G 0,75 24,5 440,0 1125,0 19 10866 25 G 1,5 20,2 360,0 745,0 16
10833 2x1 6,6 20,0 80,0 18 10867 32 G 1,5 22,6 461,0 810,0 16
Continuation
38
Flexible Control Cables / PVC Control Cables
39
Flexible Control Cables / PVC Control Cables
Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning
and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable
from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily
identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is
located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and
Arabian countries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10550 2 x 0,5 6,3 9,6 56,0 20 10582 2 x 0,75 6,6 14,4 66,0 19
10551 3 G 0,5 6,6 14,4 68,0 20 10583 3 G 0,75 6,9 21,6 74,0 19
10552 3 x 0,5 6,6 14,4 68,0 20 10584 3 x 0,75 6,9 21,6 74,0 19
10553 4 G 0,5 7,2 19,0 100,0 20 10585 4 G 0,75 7,5 29,0 126,0 19
10554 4 x 0,5 7,2 19,0 100,0 20 10586 4 x 0,75 7,5 29,0 126,0 19
10555 5 G 0,5 8,0 24,0 117,0 20 10587 5 G 0,75 8,4 36,0 140,0 19
10556 5 x 0,5 8,0 24,0 117,0 20 10588 5 x 0,75 8,4 36,0 140,0 19
10557 6 G 0,5 8,7 29,0 126,0 20 10589 6 G 0,75 9,3 43,0 170,0 19
10558 7 G 0,5 8,7 33,6 138,0 20 10590 6 x 0,75 9,3 43,0 170,0 19
10559 7 x 0,5 8,7 33,6 138,0 20 10591 7 G 0,75 9,3 50,0 190,0 19
10560 8 G 0,5 9,5 38,0 150,0 20 10592 7 x 0,75 9,3 50,0 190,0 19
10561 8 x 0,5 9,5 38,0 150,0 20 10593 8 G 0,75 10,3 58,0 212,0 19
10562 10 G 0,5 10,3 48,0 176,0 20 10594 8 x 0,75 10,3 58,0 212,0 19
10563 12 G 0,5 11,2 58,0 200,0 20 10595 9 G 0,75 11,0 65,0 227,0 19
10564 12 x 0,5 11,2 58,0 200,0 20 10596 10 G 0,75 11,0 72,0 238,0 19
10565 14 G 0,5 12,3 67,0 230,0 20 10597 12 G 0,75 12,0 86,0 257,0 19
10566 16 G 0,5 12,9 76,0 250,0 20 10598 12 x 0,75 12,0 86,0 257,0 19
10567 18 G 0,5 13,8 86,0 276,0 20 10599 14 G 0,75 12,9 101,0 286,0 19
10568 20 G 0,5 14,4 96,0 293,0 20 10600 15 G 0,75 13,8 108,0 319,0 19
10569 21 G 0,5 14,4 96,0 305,0 20 10601 18 G 0,75 14,5 130,0 362,0 19
10570 25 G 0,5 16,1 120,0 335,0 20 10602 20 G 0,75 15,4 144,0 394,0 19
10571 30 G 0,5 17,2 144,0 348,0 20 10603 21 G 0,75 15,4 151,0 422,0 19
10572 32 G 0,5 18,0 154,0 355,0 20 10604 25 G 0,75 17,2 180,0 486,0 19
10573 34 G 0,5 18,7 163,0 520,0 20 10605 32 G 0,75 19,0 230,0 595,0 19
10574 40 G 0,5 19,5 192,0 590,0 20 10606 34 G 0,75 19,9 245,0 638,0 19
10575 42 G 0,5 20,1 202,0 595,0 20 10607 37 G 0,75 19,9 260,0 696,0 19
10576 50 G 0,5 22,1 240,0 715,0 20 10608 40 G 0,75 20,7 288,0 726,0 19
10577 52 G 0,5 22,1 252,0 740,0 20 10609 41 G 0,75 21,6 296,0 750,0 19
10578 61 G 0,5 23,6 293,0 840,0 20 10610 42 G 0,75 21,6 302,0 770,0 19
10579 65 G 0,5 24,4 312,0 880,0 20 10611 50 G 0,75 23,7 360,0 895,0 19
10580 80 G 0,5 27,2 384,0 960,0 20 10612 61 G 0,75 25,3 439,0 1070,0 19
10581 100 G 0,5 31,2 480,0 1050,0 20 10613 65 G 0,75 26,3 468,0 1110,0 19
10614 80 G 0,75 28,9 576,0 1500,0 19
10615 100 G 0,75 32,2 720,0 1889,0 19
Continuation
40
Flexible Control Cables / PVC Control Cables
41
Flexible Control Cables / PVC Control Cables
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, as measuring and control cables in tool machinery, conveyor belts, production lines, as well as in machinery
production, in air-conditioning and steel production plants. The earth core is located immediately below the outer sheath. JB cables are suitable for
use in all electrical equipment either in dry or damp areas. They should not, however, be installed in the open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11001 2 x 0,5 4,8 9,6 40,0 20 11057 6G1 8,1 58,0 125,0 18
11002 3 G 0,5 5,1 14,4 46,0 20 11058 6x1 8,1 58,0 125,0 18
11003 3 x 0,5 5,1 14,4 46,0 20 11059 7G1 8,1 67,0 141,0 18
11004 4 G 0,5 5,5 19,2 56,0 20 11060 7x1 8,1 67,0 141,0 18
11005 4 x 0,5 5,5 19,2 56,0 20 11061 8G1 8,8 77,0 175,0 18
11006 5 G 0,5 6,2 24,0 65,0 20 11062 9G1 9,7 87,0 200,0 18
11007 5 x 0,5 6,2 24,0 65,0 20 11063 10 G 1 9,8 96,0 207,0 18
11008 6 G 0,5 6,7 29,0 75,0 20 11064 12 G 1 10,4 115,0 230,0 18
11009 7 G 0,5 6,7 34,0 80,0 20 11065 14 G 1 11,4 134,0 271,0 18
11010 7 x 0,5 6,7 34,0 84,0 20 11066 16 G 1 12,3 154,0 300,0 18
11011 8 G 0,5 7,4 38,0 97,0 20 11067 18 G 1 12,9 173,0 343,0 18
11012 10 G 0,5 8,2 48,0 116,0 20 11068 20 G 1 13,8 192,0 375,0 18
11013 12 G 0,5 8,7 58,0 135,0 20 11069 24 G 1 15,1 230,0 468,0 18
11014 14 G 0,5 9,5 67,0 150,0 20 11070 25 G 1 15,4 240,0 485,0 18
11015 16 G 0,5 10,0 77,0 172,0 20 11077 2 x 1,5 6,4 29,0 70,0 16
11019 30 G 0,5 13,5 144,0 310,0 20 11078 3 G 1,5 6,8 43,0 90,0 16
11026 2 x 0,75 5,3 14,4 46,0 19 11079 3 x 1,5 6,8 43,0 90,0 16
11027 3 G 0,75 5,6 21,6 54,0 19 11080 4 G 1,5 7,4 58,0 109,0 16
11028 3 x 0,75 5,6 21,6 54,0 19 11081 4 x 1,5 7,4 58,0 109,0 16
11029 4 G 0,75 6,3 28,8 66,0 19 11082 5 G 1,5 8,3 72,0 131,0 16
11030 4 x 0,75 6,3 28,8 66,0 19 11083 5 x 1,5 8,3 72,0 131,0 16
11031 5 G 0,75 6,9 36,0 80,0 19 11084 6 G 1,5 9,2 86,4 157,0 16
11032 5 x 0,75 6,9 36,0 80,0 19 11085 7 G 1,5 9,2 101,0 184,0 16
11033 6 G 0,75 7,5 43,2 99,0 19 11086 7 x 1,5 9,2 101,0 184,0 16
11034 7 G 0,75 7,5 50,0 110,0 19 11087 8 G 1,5 10,0 115,0 216,0 16
11035 7 x 0,75 7,5 50,0 110,0 19 11088 11 G 1,5 11,6 158,0 300,0 16
11036 8 G 0,75 8,3 58,0 130,0 19 11089 12 G 1,5 11,8 173,0 309,0 16
11037 9 G 0,75 8,9 65,0 153,0 19 11090 14 G 1,5 13,0 202,0 345,0 16
11038 10 G 0,75 9,2 72,0 162,0 19 11091 16 G 1,5 13,9 230,0 386,0 16
11039 12 G 0,75 9,8 86,0 179,0 19 11092 18 G 1,5 14,6 259,0 440,0 16
11040 15 G 0,75 11,4 108,0 218,0 19 11093 20 G 1,5 15,6 288,0 490,0 16
11041 18 G 0,75 12,2 130,0 257,0 19 11094 25 G 1,5 17,4 360,0 620,0 16
11042 21 G 0,75 12,7 151,0 320,0 19 11104 2 x 2,5 7,8 48,0 112,0 14
11043 25 G 0,75 14,3 180,0 365,0 19 11105 3 G 2,5 8,3 72,0 148,0 14
11050 2x1 5,6 19,2 60,0 18 11106 3 x 2,5 8,3 72,0 148,0 14
11051 3G1 5,9 29,0 72,0 18 11107 4 G 2,5 9,2 96,0 178,0 14
11052 3x1 5,9 29,0 72,0 18 11108 4 x 2,5 9,2 96,0 178,0 14
11053 4G1 6,6 38,4 86,0 18 11109 5 G 2,5 10,1 120,0 221,0 14
11054 4x1 6,6 38,4 86,0 18 11110 5 x 2,5 10,1 120,0 221,0 14
11055 5G1 7,3 48,0 104,0 18 11111 6 G 2,5 11,2 144,0 293,0 14
11056 5x1 7,3 48,0 104,0 18 11112 7 G 2,5 11,2 168,0 306,0 14
42
Flexible Control Cables / PVC Control Cables
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, as measuring and control cables in tool machinery, conveyor belts, production lines, as well as in machinery
production, in air-conditioning and steel production plants. The earth core is located immediately below the outer sheath. JB cables are suitable for
use in all electrical equipment either in dry or damp areas. They should not, however, be installed in the open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11161 2 x 2,5 8,6 48,0 130,0 14 11155 3 G 25 24,4 720,0 1388,0 4
11162 3 G 2,5 9,3 72,0 164,0 14 11136 4 G 25 27,1 960,0 1581,0 4
11163 3 x 2,5 9,3 72,0 164,0 14 11137 5 G 25 30,1 1200,0 1997,0 4
11164 4 G 2,5 10,2 96,0 200,0 14 11156 3 G 35 27,0 1008,0 1767,0 2
11165 4 x 2,5 10,2 96,0 200,0 14 11138 4 G 35 29,9 1344,0 2105,0 2
11166 5 G 2,5 11,4 120,0 247,0 14 11139 5 G 35 33,4 1680,0 2636,0 2
11167 5 x 2,5 11,4 120,0 247,0 14 11157 3 G 50 31,9 1440,0 2556,0 1
11168 6 G 2,5 12,6 144,0 301,0 14 11140 4 G 50 35,5 1920,0 2940,0 1
11169 7 G 2,5 12,6 168,0 321,0 14 11145 5 G 50 39,2 2400,0 3936,0 1
11121 2x4 10,6 76,8 195,0 12 11158 3 G 70 36,4 2016,0 3182,0 2/0
11144 3G4 11,3 115,0 235,0 12 11141 4 G 70 40,2 2688,0 4090,0 2/0
11122 4G4 12,5 154,0 295,0 12 11146 5 G 70 44,9 3360,0 5443,0 2/0
11123 5G4 13,9 192,0 361,0 12 11159 3 G 95 41,5 2736,0 4676,0 3/0
11124 7G4 15,4 269,0 498,0 12 11142 4 G 95 46,0 3648,0 5540,0 3/0
11125 11 G 4 20,2 422,0 767,0 12 11147 5 G 95 51,3 4560,0 6931,0 3/0
11126 3G6 12,8 173,0 355,0 10 11160 3 G 120 45,9 3456,0 5630,0 4/0
11127 4G6 14,2 230,0 424,0 10 11143 4 G 120 51,3 4608,0 7000,0 4/0
11128 5G6 15,8 288,0 525,0 10 11148 4 G 150 58,7 5760,0 8340,0 300 kcmil
11129 7G6 17,4 403,0 625,0 10 11149 4 G 185 64,3 7104,0 9904,0 350 kcmil
11153 3 G 10 16,2 290,0 611,0 8
11130 4 G 10 18,1 384,0 701,0 8
11131 5 G 10 20,1 480,0 858,0 8
11132 7 G 10 22,2 672,0 1106,0 8
11154 3 G 16 19,8 461,0 912,0 6
11133 4 G 16 22,0 614,0 1035,0 6
11134 5 G 16 24,4 768,0 1259,0 6
11135 7 G 16 27,0 1075,0 1780,0 6
43
Flexible Control Cables / PVC Control Cables
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air, as connection cable with yellow outer sheath as a special warning indication. Recommendation in
accordance to EN 60204 part 1 and DIN VDE 0113 part 1.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10334 3 G 1,5 7,8 43,0 100,0 16 10337 3 G 2,5 9,3 72,0 154,0 14
10335 4 G 1,5 8,5 58,0 121,0 16 10338 4 G 2,5 10,2 96,0 208,0 14
10336 5 G 1,5 9,6 72,0 148,0 16 10339 5 G 2,5 11,4 120,0 229,0 14
44
Flexible Control Cables / PVC Control Cables
H03VV-F
A
Application
These cable types are especially suited to use on small appliances with low mechanical stress and for connection for light household appliances, e. g.
kitchen utensils, desk lamps, floor lamps, vacuum cleaners, office machines, radios, etc. , as far as this cable is admitted to the relevant specifications
of the equipment.
These cables are not permitted to use with cooking or heating apparatus.
Cables with cross-section 0,75 mm are not suitable for outdoor use or use of industrial or farmer machineries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Sheath Outer Cop. Weight AWG-No. Part no. No.cores x Sheath Outer Cop. Weight AWG-No.
cross-sec. colour min. - max. weight approx. cross-sec. colour min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
29736 2 x 0,5 black 4,6 - 5,9 9,6 40,0 20 29406 4 G 0,75 black 5,7 - 7,3 29,0 72,0 19
29737 2 x 0,5 white 4,6 - 5,9 9,6 40,0 20 29407 4 G 0,75 white 5,7 - 7,3 29,0 72,0 19
29738 2 x 0,5 other colours 4,6 - 5,9 9,6 40,0 20 29408 4 G 0,75 other colours 5,7 - 7,3 29,0 72,0 19
29739 3 G 0,5 black 4,9 - 6,3 14,4 49,0 20 29409 5 G 0,75 black 6,5 - 8,2 36,0 87,0 19
29740 3 G 0,5 white 4,9 - 6,3 14,4 49,0 20 29410 5 G 0,75 white 6,5 - 8,2 36,0 87,0 19
29741 3 G 0,5 other colours 4,9 - 6,3 14,4 49,0 20 29411 5 G 0,75 other colours 6,5 - 8,2 36,0 87,0 19
29742 4 G 0,5 black 5,4 - 6,9 19,2 61,0 20 29412 6 G 0,75 black 7,1 - 9,0 43,0 98,0 19
29743 4 G 0,5 white 5,4 - 6,9 19,2 61,0 20 29413 6 G 0,75 white 7,1 - 9,0 43,0 98,0 19
29744 4 G 0,5 other colours 5,4 - 6,9 19,2 61,0 20 29414 6 G 0,75 other colours 7,1 - 9,0 43,0 98,0 19
29400 2 x 0,75 black 4,9 - 6,3 14,4 49,0 19 29415 7 G 0,75 black 7,1 - 9,0 50,0 108,0 19
29401 2 x 0,75 white 4,9 - 6,3 14,4 49,0 19 29416 7 G 0,75 white 7,1 - 9,0 50,0 108,0 19
29402 2 x 0,75 other colours 4,9 - 6,3 14,4 49,0 19 29417 7 G 0,75 other colours 7,1 - 9,0 50,0 108,0 19
29403 3 G 0,75 black 5,2 - 6,7 21,6 59,0 19
29404 3 G 0,75 white 5,2 - 6,7 21,6 59,0 19
29405 3 G 0,75 other colours 5,2 - 6,7 21,6 59,0 19
45
Flexible Control Cables / PVC Control Cables
H05VV-F
Application
These cables are especially suited to use for the appliance with medium mechanical stress in households, kitchens and offices, also for household
appliances in damp and wet areas, e. g. refrigerators, washing machines, spin-driver etc. As far as this cable is admitted to the relevant specifications
of the equipment.
These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact with hot parts of
the apparatus and no other influences of heat.
The cables are suitable for fixed installation in furnitures, partition walls, decoration covering and in hollow spaces of prefabricated building parts.
They are not qualified for use in outdoors or for use with industrial and farmer machineries, exceptionally in tailoring, etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Sheath Outer Cop. Weight AWG-No. Part no. No.cores x Sheath Outer Cop. Weight AWG-No.
cross-sec. colour min. - max. weight approx. cross-sec. colour min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
29450 2 x 0,75 black 5,7 - 7,2 14,4 50,0 19 29474 7 G 1,5 black 11,3 - 14,0 101,0 183,0 16
29451 2 x 0,75 white 5,7 - 7,2 14,4 50,0 19 29475 7 G 1,5 white 11,3 - 14,0 101,0 183,0 16
29452 3 G 0,75 black 6,0 - 7,6 21,6 60,0 19 29478 3 G 2,5 black 9,2 - 11,4 72,0 152,0 14
29453 3 G 0,75 white 6,0 - 7,6 21,6 60,0 19 29479 3 G 2,5 white 9,2 - 11,4 72,0 152,0 14
29454 4 G 0,75 black 6,6 - 8,3 29,0 73,0 19 29480 4 G 2,5 black 10,1 - 12,5 96,0 192,0 14
29455 4 G 0,75 white 6,6 - 8,3 29,0 73,0 19 29481 4 G 2,5 white 10,1 - 12,5 96,0 192,0 14
29456 5 G 0,75 black 7,4 - 9,3 36,0 88,0 19 29482 5 G 2,5 black 11,2 - 13,9 120,0 243,0 14
29457 5 G 0,75 white 7,4 - 9,3 36,0 88,0 19 29483 5 G 2,5 white 11,2 - 13,9 120,0 243,0 14
29458 2x1 black 5,9 - 7,5 19,0 57,0 18 29486 7 G 2,5 black 13,8 - 17,1 168,0 316,0 14
29459 2x1 white 5,9 - 7,5 19,0 57,0 18 29487 7 G 2,5 white 13,8 - 17,1 168,0 316,0 14
29460 3G1 black 6,3 - 8,0 29,0 73,0 18 29825 3G4 black 10,5 - 13,1 115,0 235,0 12
29461 3G1 white 6,3 - 8,0 29,0 73,0 18 29826 3G4 white 10,5 - 13,1 115,0 235,0 12
29462 4G1 black 7,1 - 9,0 38,0 85,0 18 29488 4G4 black 11,5 - 14,3 154,0 300,0 12
29463 4G1 white 7,1 - 9,0 38,0 85,0 18 29489 4G4 white 11,5 - 14,3 154,0 300,0 12
29464 5G1 black 7,8 - 9,8 48,0 105,0 18 29490 5G4 black 13,0 - 16,1 192,0 361,0 12
29465 5G1 white 7,8 - 9,8 48,0 105,0 18 29491 5G4 white 13,0 - 16,1 192,0 361,0 12
29466 7G1 black 9,7 - 12,1 67,0 131,0 18 29492 4G6 black 12,9 - 15,9 230,0 490,0 10
29467 7G1 white 9,7 - 12,1 67,0 131,0 18 29493 4G6 white 12,9 - 15,9 230,0 490,0 10
29484 2 x 1,5 black 6,8 - 8,6 29,0 82,0 16
29485 2 x 1,5 white 6,8 - 8,6 29,0 82,0 16
29468 3 G 1,5 black 7,4 - 9,4 43,0 95,0 16
29469 3 G 1,5 white 7,4 - 9,4 43,0 95,0 16
29470 4 G 1,5 black 8,4 - 10,5 58,0 117,0 16
29471 4 G 1,5 white 8,4 - 10,5 58,0 117,0 16
29472 5 G 1,5 black 9,3 - 11,6 72,0 144,0 16
29473 5 G 1,5 white 9,3 - 11,6 72,0 144,0 16
46
Flexible Control Cables / PVC Control Cables
H05VV-F
A
Application
These cable are especially suited to use for the appliance with medium mechanical stress in households, kitchens and offices, also for household
appliances in damp and wet areas, e. g. refrigerators, washing machines, spin-driver etc. As far as this cable is admitted to the relevant specifications
of the equipment. These cables are suited to be used for cooking and heating apparatus under the condition that cable does not come in direct contact
with hot parts of the apparatus and no other influences of heat. The cables are suitable for fixed installation in furnitures, partition walls, decoration
covering and in hollow spaces of prefabricated building parts.
They are not qualified for use in outdoors or for use with industrial and farmer machineries, exceptionally in tailoring, etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
3011x 2 x 0,75 5,7 - 7,2 14,4 50,0 19 3020x 2 x 1,5 6,8 - 8,6 29,0 82,0 16
3012x 3 G 0,75 6,0 - 7,6 21,6 60,0 19 3021x 3 G 1,5 7,4 - 9,4 43,0 95,0 16
3013x 4 G 0,75 6,6 - 8,3 29,0 73,0 19 3022x 4 G 1,5 8,4 - 10,5 58,0 117,0 16
3014x 5 G 0,75 7,4 - 9,3 36,0 88,0 19 3023x 5 G 1,5 9,3 - 11,6 72,0 144,0 16
3015x 2x1 5,9 - 7,5 19,0 57,0 18 3024x 3 G 2,5 9,2 - 11,4 72,0 152,0 14
3016x 3G1 6,3 - 8,0 29,0 73,0 18 3025x 4 G 2,5 10,1 - 12,5 96,0 192,0 14
3017x 4G1 7,1 - 9,0 38,0 85,0 18 3026x 5 G 2,5 11,2 - 13,9 120,0 243,0 14
3018x 5G1 7,8 - 9,8 48,0 105,0 18
47
Flexible Control Cables / PVC Control Cables
Application
For flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not in open air, as data cable in the
control and regulation technology, tool and machinery, in computer systems, as well as signal line in the electronic. A stabilizing foil separator between
wire bound and braid reduces the outer diameter essentially and allows smaller bending radius, lower weight etc. The disturbance free transmission
of signals and impulses is ensured due to the high degree of screening. This is an ideal disturbance-free control cable for the above applications.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16531 1 x 0,5 3,7 15,0 41,0 20 16544 20 x 0,5 12,3 172,0 240,0 20
16532 2 x 0,5 5,7 35,0 45,0 20 16545 21 x 0,5 12,3 188,0 250,0 20
16533 3 x 0,5 5,9 42,0 55,0 20 16546 24 x 0,5 13,6 235,0 300,0 20
16534 4 x 0,5 6,4 47,0 61,0 20 16547 25 x 0,5 13,7 240,0 314,0 20
16535 5 x 0,5 6,9 56,0 74,0 20 16548 30 x 0,5 14,4 295,0 360,0 20
16536 6 x 0,5 7,6 67,0 89,0 20 16549 32 x 0,5 14,9 301,0 425,0 20
16537 7 x 0,5 7,6 69,0 98,0 20 16550 34 x 0,5 15,5 312,0 433,0 20
16538 8 x 0,5 8,1 80,0 117,0 20 16551 36 x 0,5 15,5 318,0 446,0 20
16539 10 x 0,5 9,6 94,0 135,0 20 16552 40 x 0,5 16,5 343,0 475,0 20
16540 12 x 0,5 9,7 108,0 157,0 20 16553 50 x 0,5 18,5 406,0 573,0 20
16541 14 x 0,5 10,2 116,0 190,0 20 16554 61 x 0,5 19,7 508,0 653,0 20
16542 16 x 0,5 11,0 129,0 210,0 20 16555 80 x 0,5 22,6 680,0 784,0 20
16543 18 x 0,5 11,5 145,0 217,0 20 16556 100 x 0,5 24,9 804,0 995,0 20
Continuation
48
Flexible Control Cables / PVC Control Cables
49
Flexible Control Cables / PVC Control Cables
Application
For use as a data cable in control circuits, in tool-making and machine industries as well as a signal cable in computer systems and electronics. The
more usual PVC inner sheath has been replaced in these cables by a stabilising foil separator, thus reducing the total diameter of the cables considerably
and thereby reducing the bending radius, total weight etc. The high covering percentage of the copper screening offers interference-free signal transfer
etc. The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above
application.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16320 2 x 0,5 5,7 35,0 45,0 20 16333 21 G 0,5 12,3 188,0 250,0 20
16321 3 G 0,5 5,9 42,0 55,0 20 16334 24 G 0,5 13,6 235,0 300,0 20
16322 4 G 0,5 6,4 47,0 61,0 20 16335 25 G 0,5 13,7 240,0 314,0 20
16323 5 G 0,5 6,9 56,0 74,0 20 16336 30 G 0,5 14,4 295,0 360,0 20
16324 6 G 0,5 7,6 67,0 89,0 20 16337 32 G 0,5 14,9 301,0 425,0 20
16325 7 G 0,5 7,6 69,0 98,0 20 16165 34 G 0,5 15,6 312,0 433,0 20
16326 8 G 0,5 8,1 80,0 117,0 20 16338 36 G 0,5 15,6 318,0 446,0 20
16327 10 G 0,5 9,6 94,0 135,0 20 16339 40 G 0,5 16,4 343,0 475,0 20
16328 12 G 0,5 9,7 108,0 157,0 20 16490 41 G 0,5 16,5 348,0 486,0 20
16329 14 G 0,5 10,2 116,0 190,0 20 16340 50 G 0,5 18,5 406,0 573,0 20
16330 16 G 0,5 11,0 129,0 210,0 20 16341 61 G 0,5 19,7 508,0 653,0 20
16331 18 G 0,5 11,5 145,0 217,0 20 16342 80 G 0,5 22,6 680,0 784,0 20
16332 20 G 0,5 12,3 172,0 240,0 20 16343 100 G 0,5 24,9 804,0 995,0 20
Continuation
50
Flexible Control Cables / PVC Control Cables
51
Flexible Control Cables / PVC Control Cables
Application
For medium mechanical stress for flexible use with free movement without tensile stress or forced movements in dry, damp, wet rooms and in open
air. Must not be laid directly in soil or water. When screened for measurement, control and control line etc. in mechanical and plant engineering,
machine tools, production lines and conveyor belts.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
10934 2 x 0,5 6,1 35,0 45,0 20 11499 12 x 1 12,4 184,0 260,0 18
10935 3 G 0,5 6,4 42,0 55,0 20 10956 18 G 1 14,7 260,0 380,0 18
11479 3 x 0,5 6,4 42,0 55,0 20 10957 25 G 1 17,5 349,0 534,0 18
10936 4 G 0,5 6,8 47,0 61,0 20 10958 2 x 1,5 7,8 63,0 88,0 16
11480 4 x 0,5 6,8 47,0 61,0 20 10959 3 G 1,5 8,2 80,0 100,0 16
10937 5 G 0,5 7,5 56,0 74,0 20 11500 3 x 1,5 8,2 80,0 100,0 16
11481 5 x 0,5 7,5 56,0 74,0 20 10960 4 G 1,5 8,9 97,0 126,0 16
10938 7 G 0,5 8,1 69,0 98,0 20 11502 4 x 1,5 8,9 97,0 126,0 16
11482 7 x 0,5 8,1 69,0 98,0 20 10961 5 G 1,5 9,8 119,0 160,0 16
10939 12 G 0,5 10,6 108,0 157,0 20 11503 5 x 1,5 9,8 119,0 160,0 16
11483 12 x 0,5 10,6 108,0 157,0 20 10962 7 G 1,5 10,8 147,0 208,0 16
10940 18 G 0,5 12,4 145,0 217,0 20 11520 7 x 1,5 10,8 147,0 208,0 16
10941 25 G 0,5 14,7 240,0 314,0 20 10963 12 G 1,5 14,0 267,0 338,0 16
10942 2 x 0,75 6,7 40,0 59,0 19 11522 12 x 1,5 14,0 267,0 338,0 16
10943 3 G 0,75 7,0 52,0 66,0 19 10964 18 G 1,5 16,8 374,0 479,0 16
11484 3 x 0,75 7,0 52,0 66,0 19 10965 25 G 1,5 19,8 526,0 705,0 16
10944 4 G 0,75 7,7 60,0 77,0 19 10966 2 x 2,5 9,2 96,0 130,0 14
11485 4 x 0,75 7,7 60,0 77,0 19 10967 3 G 2,5 9,8 144,0 167,0 14
10945 5 G 0,75 8,2 71,0 93,0 19 11523 3 x 2,5 9,8 144,0 167,0 14
11486 5 x 0,75 8,2 71,0 93,0 19 10968 4 G 2,5 10,6 148,0 195,0 14
10946 7 G 0,75 9,0 91,0 130,0 19 11524 4 x 2,5 10,6 148,0 195,0 14
11487 7 x 0,75 9,0 91,0 130,0 19 10969 5 G 2,5 11,7 181,0 223,0 14
10947 12 G 0,75 11,6 142,0 202,0 19 11526 5 x 2,5 11,7 181,0 223,0 14
11488 12 x 0,75 11,6 142,0 202,0 19 10970 7 G 2,5 12,8 255,0 344,0 14
10948 18 G 0,75 13,7 212,0 292,0 19 11527 7 x 2,5 12,8 255,0 344,0 14
10949 25 G 0,75 16,4 281,0 415,0 19 10971 12 G 2,5 17,0 441,0 570,0 14
10950 2x1 7,0 50,0 65,0 18 11550 12 x 2,5 17,0 441,0 570,0 14
10951 3G1 7,5 60,0 80,0 18 10972 18 G 2,5 19,8 570,0 681,0 14
11493 3x1 7,5 60,0 80,0 18 10973 4G4 12,4 230,0 310,0 12
10952 4G1 8,0 71,0 98,0 18 10974 5G4 13,7 273,0 385,0 12
11495 4x1 8,0 71,0 98,0 18 10975 4G6 14,7 305,0 415,0 10
10953 5G1 8,8 88,0 127,0 18 10976 5G6 16,2 439,0 509,0 10
11496 5x1 8,8 88,0 127,0 18 10977 4 G 10 18,2 535,0 783,0 8
10954 7G1 9,5 111,0 158,0 18 10978 4 G 16 21,1 740,0 880,0 6
11497 7x1 9,5 111,0 158,0 18 10979 4 G 25 25,8 1140,0 1570,0 4
10955 12 G 1 12,4 184,0 260,0 18 10980 4 G 35 29,7 1576,0 2070,0 2
52
Flexible Control Cables / PVC Control Cables
Application
For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a
high degree of interference protection. The screening density assures disturbancefree transmission of all signals and impulses. The PVC-inner sheaths
of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical view of the tinned copper braid.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16200 2 x 0,5 7,0 41,0 67,0 20 16219 50 G 0,5 20,7 407,0 740,0 20
16201 3 G 0,5 7,3 45,0 83,0 20 16220 61 G 0,5 22,0 520,0 850,0 20
16169 3 x 0,5 7,3 45,0 83,0 20 16221 80 G 0,5 25,0 690,0 1080,0 20
16202 4 G 0,5 7,9 54,0 94,0 20 16222 100 G 0,5 27,4 805,0 1350,0 20
16170 4 x 0,5 7,9 54,0 94,0 20 16223 2 x 0,75 7,7 46,0 87,0 19
16203 5 G 0,5 8,4 66,0 108,0 20 16224 3 G 0,75 8,0 57,0 98,0 19
16171 5 x 0,5 8,4 66,0 108,0 20 16173 3 x 0,75 8,0 57,0 98,0 19
16204 6 G 0,5 9,1 73,0 125,0 20 16225 4 G 0,75 8,5 63,0 113,0 19
16205 7 G 0,5 9,1 79,0 136,0 20 16196 4 x 0,75 8,5 63,0 113,0 19
17172 7 x 0,5 9,1 79,0 136,0 20 16226 5 G 0,75 9,3 76,0 130,0 19
16206 8 G 0,5 9,7 82,0 150,0 20 16174 5 x 0,75 9,3 76,0 130,0 19
16207 10 G 0,5 10,7 107,0 170,0 20 16227 6 G 0,75 9,9 82,0 156,0 19
16208 12 G 0,5 11,5 137,0 195,0 20 16228 7 G 0,75 9,9 100,0 184,0 19
16209 14 G 0,5 12,2 142,0 223,0 20 16175 7 x 0,75 9,9 100,0 184,0 19
16210 16 G 0,5 12,7 147,0 250,0 20 16229 8 G 0,75 10,6 112,0 221,0 19
16211 18 G 0,5 13,5 156,0 277,0 20 16230 10 G 0,75 11,8 140,0 270,0 19
16212 20 G 0,5 14,2 173,0 310,0 20 16231 12 G 0,75 12,7 175,0 292,0 19
16315 21 G 0,5 14,2 189,0 331,0 20 16232 14 G 0,75 13,3 190,0 315,0 19
16213 24 G 0,5 15,5 236,0 390,0 20 16233 16 G 0,75 14,1 204,0 335,0 19
16214 25 G 0,5 15,7 250,0 407,0 20 16234 18 G 0,75 14,9 240,0 358,0 19
16215 30 G 0,5 16,2 297,0 520,0 20 16235 20 G 0,75 15,4 262,0 420,0 19
16216 32 G 0,5 17,0 312,0 550,0 20 16316 21 G 0,75 15,4 274,0 454,0 19
16217 36 G 0,5 17,7 320,0 585,0 20 16236 24 G 0,75 17,3 291,0 480,0 19
16218 40 G 0,5 18,4 345,0 654,0 20 16237 25 G 0,75 17,5 306,0 508,0 19
16453 41 G 0,5 18,9 348,0 671,0 20 16238 27 G 0,75 17,7 326,0 535,0 19
16239 30 G 0,75 18,3 340,0 640,0 19
Continuation
53
Flexible Control Cables / PVC Control Cables
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16240 32 G 0,75 18,9 349,0 688,0 19 16282 20 G 1,5 18,5 401,0 690,0 16
16241 36 G 0,75 19,7 358,0 730,0 19 16317 21 G 1,5 18,5 447,0 720,0 16
16242 40 G 0,75 20,4 371,0 950,0 19 16283 24 G 1,5 20,4 487,0 770,0 16
16454 41 G 0,75 21,0 403,0 971,0 19 16284 25 G 1,5 20,8 531,0 805,0 16
16243 50 G 0,75 23,2 470,0 1100,0 19 16285 28 G 1,5 21,4 562,0 900,0 16
16244 61 G 0,75 24,6 550,0 1290,0 19 16286 30 G 1,5 21,6 598,0 950,0 16
16245 80 G 0,75 28,3 715,0 1510,0 19 16287 35 G 1,5 23,2 685,0 1100,0 16
16246 100 G 0,75 31,1 910,0 1640,0 19 16288 40 G 1,5 24,5 759,0 1350,0 16
16248 2x1 8,0 54,0 97,0 18 16456 41 G 1,5 25,0 840,0 1381,0 16
16249 3G1 8,3 64,0 103,0 18 16289 50 G 1,5 27,4 997,0 1675,0 16
16176 3x1 8,3 64,0 103,0 18 16290 61 G 1,5 29,2 1120,0 1800,0 16
16250 4G1 9,0 76,0 146,0 18 16291 80 G 1,5 33,4 1360,0 2300,0 16
16177 4x1 9,0 76,0 146,0 18 16292 100 G 1,5 36,8 1690,0 2600,0 16
16251 5G1 9,7 89,0 169,0 18 16293 2 x 2,5 10,1 110,0 180,0 14
16178 5x1 9,7 89,0 169,0 18 16294 3 G 2,5 10,8 148,0 216,0 14
16252 6G1 10,3 101,0 199,0 18 16295 4 G 2,5 11,5 169,0 267,0 14
16253 7G1 10,3 114,0 219,0 18 16296 5 G 2,5 12,8 220,0 347,0 14
16179 7x1 10,3 114,0 219,0 18 16297 7 G 2,5 14,0 284,0 407,0 14
16254 8G1 11,2 130,0 270,0 18 16298 10 G 2,5 16,8 369,0 660,0 14
16255 10 G 1 12,6 156,0 330,0 18 16318 12 G 2,5 17,9 470,0 722,0 14
16256 12 G 1 13,3 186,0 350,0 18 16299 2x4 11,6 124,0 302,0 12
16257 14 G 1 14,1 198,0 400,0 18 16300 3G4 12,5 178,0 340,0 12
16258 16 G 1 14,8 214,0 422,0 18 16301 4G4 13,7 234,0 410,0 12
16259 18 G 1 15,6 284,0 514,0 18 16302 5G4 14,9 284,0 502,0 12
16260 20 G 1 16,4 325,0 545,0 18 16303 7G4 16,2 321,0 638,0 12
16261 24 G 1 18,2 366,0 640,0 18 16304 2x6 13,7 176,0 350,0 10
16262 25 G 1 18,5 387,0 689,0 18 16305 3G6 14,4 245,0 450,0 10
16263 28 G 1 19,1 421,0 710,0 18 16306 4G6 15,7 316,0 559,0 10
16264 30 G 1 19,2 457,0 762,0 18 16307 5G6 17,3 442,0 702,0 10
16265 34 G 1 20,9 500,0 910,0 18 16308 7G6 19,0 530,0 907,0 10
16266 40 G 1 21,5 536,0 1070,0 18 16309 2 x 10 16,6 260,0 500,0 8
16455 41 G 1 22,2 578,0 1092,0 18 16310 3 G 10 17,6 367,0 750,0 8
16267 50 G 1 24,8 681,0 1315,0 18 16311 4 G 10 19,4 549,0 1020,0 8
16268 61 G 1 26,0 710,0 1370,0 18 16312 5 G 10 21,3 604,0 1115,0 8
16269 80 G 1 30,0 940,0 1610,0 18 16313 7 G 10 23,4 820,0 1500,0 8
16270 100 G 1 33,1 1180,0 1840,0 18 16460 4 G 16 23,4 807,0 1380,0 6
16271 2 x 1,5 8,6 64,0 130,0 16 16314 5 G 16 26,0 940,0 1553,0 6
16272 3 G 1,5 9,2 82,0 152,0 16 16461 4 G 25 28,3 1169,0 1890,0 4
16180 3 x 1,5 9,2 82,0 152,0 16 16462 5 G 25 31,5 1420,0 2270,0 4
16273 4 G 1,5 9,8 99,0 168,0 16 16463 4 G 35 32,9 1680,0 2390,0 2
16181 4 x 1,5 9,8 99,0 168,0 16 16464 5 G 35 36,9 2020,0 2885,0 2
16274 5 G 1,5 10,8 123,0 202,0 16 16465 4 G 50 38,6 2370,0 3315,0 1
16182 5 x 1,5 10,8 123,0 202,0 16 16157 5 G 50 43,5 2880,0 4150,0 1
16275 7 G 1,5 11,7 148,0 304,0 16 16466 4 G 70 46,1 3257,0 4600,0 2/0
16183 7 x 1,5 11,7 148,0 304,0 16 16158 5 G 70 50,5 4032,0 5750,0 2/0
16276 8 G 1,5 12,6 172,0 336,0 16 16467 4 G 95 51,1 4060,0 6060,0 3/0
16277 10 G 1,5 14,2 198,0 420,0 16 16159 5 G 95 56,0 5244,0 7580,0 3/0
16278 12 G 1,5 14,9 274,0 434,0 16 16468 4 G 120 56,5 5231,0 7315,0 4/0
16279 14 G 1,5 15,8 294,0 480,0 16 16160 5 G 120 62,1 6624,0 9150,0 4/0
16280 16 G 1,5 16,7 318,0 525,0 16 16167 4 G 150 64,6 7760,0 9680,0 300 kcmil
16281 18 G 1,5 17,4 386,0 640,0 16 16168 5 G 150 70,6 8496,0 10170,0 300 kcmil
54
Flexible Control Cables / PVC Control Cables
SY-JZ flexible, number coded, with steel wire braiding, meter marking
Application
SY-JZ cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The braided screen
offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect against corrosion,
but also notably improves the soldering performance.
The clear transparent outer sheath gives the cable in addition an optical revaluation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12001 2 x 0,5 7,2 9,6 80,0 20 12027 18 G 0,75 15,0 130,0 388,0 19
12002 3 G 0,5 7,5 14,4 92,0 20 12028 21 G 0,75 15,5 151,0 474,0 19
12003 4 G 0,5 8,1 19,2 102,0 20 12029 25 G 0,75 17,5 180,0 503,0 19
12004 5 G 0,5 8,6 24,0 119,0 20 12030 32 G 0,75 18,9 230,0 644,0 19
12005 7 G 0,5 9,3 33,6 157,0 20 12031 34 G 0,75 19,9 245,0 663,0 19
12006 10 G 0,5 10,7 48,0 205,0 20 12032 41 G 0,75 21,2 296,0 741,0 19
12007 12 G 0,5 11,7 58,0 218,0 20 12033 50 G 0,75 23,2 360,0 925,0 19
12008 14 G 0,5 12,3 67,0 242,0 20 12034 61 G 0,75 25,2 439,0 1082,0 19
12009 18 G 0,5 13,4 86,0 340,0 20 12035 2x1 8,2 19,2 112,0 18
12010 21 G 0,5 14,2 101,0 370,0 20 12036 3G1 8,5 28,8 132,0 18
12114 25 G 0,5 15,7 120,0 406,0 20 12037 4G1 9,2 38,4 143,0 18
12012 30 G 0,5 16,2 144,0 439,0 20 12038 5G1 9,9 48,0 166,0 18
12013 35 G 0,5 17,5 168,0 500,0 20 12039 6G1 10,5 58,0 22,0 18
12014 40 G 0,5 18,2 192,0 565,0 20 12040 7G1 10,5 67,0 227,0 18
12015 42 G 0,5 19,0 202,0 593,0 20 12041 8G1 11,4 77,0 277,0 18
12016 50 G 0,5 20,7 240,0 690,0 20 12042 9G1 12,8 86,0 295,0 18
12017 61 G 0,5 22,0 293,0 843,0 20 12043 12 G 1 13,4 115,0 340,0 18
12018 80 G 0,5 25,0 384,0 1050,0 20 12044 14 G 1 14,2 134,0 420,0 18
12011 100 G 0,5 27,4 480,0 1240,0 20 12045 18 G 1 15,7 173,0 500,0 18
12019 2 x 0,75 7,9 14,4 98,0 19 12046 20 G 1 16,4 192,0 532,0 18
12020 3 G 0,75 8,2 21,6 103,0 19 12047 25 G 1 18,4 240,0 664,0 18
12021 4 G 0,75 8,7 28,8 122,0 19 12048 34 G 1 20,8 326,0 845,0 18
12022 5 G 0,75 9,5 36,0 142,0 19 12049 36 G 1 20,9 346,0 857,0 18
12112 6 G 0,75 10,1 43,2 180,0 19 12050 41 G 1 22,2 394,0 993,0 18
12023 7 G 0,75 10,1 50,0 185,0 19 12051 50 G 1 24,4 480,0 1112,0 18
12188 8 G 0,75 10,8 57,6 201,0 19 12052 56 G 1 25,5 538,0 1225,0 18
12024 9 G 0,75 11,8 65,0 249,0 19 12053 61 G 1 26,1 586,0 1306,0 18
12113 10 G 0,75 12,0 72,0 252,0 19 12054 65 G 1 26,9 624,0 1504,0 18
12025 12 G 0,75 12,8 86,0 292,0 19 12055 80 G 1 30,0 768,0 1750,0 18
12026 15 G 0,75 14,2 108,0 335,0 19 12056 100 G 1 33,1 960,0 1950,0 18
Continuation
55
Flexible Control Cables / PVC Control Cables
SY-JZ flexible, number coded, with steel wire braiding, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12057 2 x 1,5 8,8 29,0 129,0 16 12115 3G4 12,6 117,0 350,0 12
12058 3 G 1,5 9,4 43,0 149,0 16 12091 4G4 13,7 154,0 428,0 12
12059 4 G 1,5 10,0 58,0 185,0 16 12092 5G4 14,9 192,0 504,0 12
12060 5 G 1,5 10,9 72,0 205,0 16 12093 7G4 16,2 269,0 640,0 12
12109 6 G 1,5 11,8 87,0 255,0 16 12094 11 G 4 21,2 422,0 1204,0 12
12061 7 G 1,5 11,8 101,0 285,0 16 12095 4G6 15,8 230,0 571,0 10
12062 8 G 1,5 12,7 115,0 340,0 16 12096 5G6 17,3 288,0 671,0 10
12063 9 G 1,5 13,9 130,0 347,0 16 12097 7G6 19,0 403,0 845,0 10
12064 10 G 1,5 14,3 144,0 418,0 16 12098 4 G 10 19,4 384,0 943,0 8
12065 11 G 1,5 14,8 158,0 430,0 16 12099 5 G 10 21,3 480,0 1065,0 8
12066 12 G 1,5 15,0 173,0 444,0 16 12100 7 G 10 23,4 672,0 1551,0 8
12067 14 G 1,5 15,8 202,0 533,0 16 12101 4 G 16 23,6 614,0 1360,0 6
12068 18 G 1,5 17,4 259,0 593,0 16 12102 5 G 16 26,4 768,0 1740,0 6
12069 25 G 1,5 20,8 360,0 781,0 16 12103 7 G 16 29,0 1075,0 2166,0 6
12070 32 G 1,5 22,3 461,0 1015,0 16 12104 4 G 25 28,5 960,0 2020,0 4
12071 34 G 1,5 23,2 490,0 1124,0 16 12105 5 G 25 31,7 1200,0 2465,0 4
12072 42 G 1,5 25,2 605,0 1401,0 16 12106 4 G 35 32,9 1344,0 2570,0 2
12073 50 G 1,5 27,6 720,0 1583,0 16 12107 5 G 35 36,9 1680,0 3185,0 2
12074 61 G 1,5 29,4 878,0 1810,0 16 12108 4 G 50 38,8 1920,0 3513,0 1
12075 80 G 1,5 33,8 1152,0 2316,0 16 12116 5 G 50 43,7 2400,0 4248,0 1
12076 100 G 1,5 37,2 1440,0 2900,0 16 12111 4 G 70 46,3 2688,0 4810,0 2/0
12077 2 x 2,5 10,2 48,0 185,0 14 12117 5 G 70 50,5 3360,0 5880,0 2/0
12078 3 G 2,5 10,9 72,0 248,0 14 12110 4 G 95 51,2 3648,0 6360,0 3/0
12079 4 G 2,5 11,6 96,0 290,0 14 12118 5 G 95 56,1 4560,0 8071,0 3/0
12080 5 G 2,5 12,9 120,0 347,0 14 12119 4 G 120 56,6 4608,0 8170,0 4/0
12081 7 G 2,5 14,2 168,0 420,0 14 12327 4 G 150 64,7 5760,0 9970,0 300 kcmil
12082 12 G 2,5 17,7 288,0 660,0 14
12083 14 G 2,5 18,8 336,0 750,0 14
12084 18 G 2,5 21,0 432,0 893,0 14
12085 20 G 2,5 22,3 480,0 1169,0 14
12086 25 G 2,5 24,8 600,0 1458,0 14
12087 30 G 2,5 26,0 720,0 1686,0 14
12088 34 G 2,5 28,4 816,0 1869,0 14
12089 50 G 2,5 34,0 1200,0 2200,0 14
12090 61 G 2,5 36,2 1464,0 3000,0 14
56
Flexible Control Cables / PVC Control Cables
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and
production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants
and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement. The interconnection of
parts of machines used for manufacturing purposes including machine tools where some degree of protection against electromagnetic interference
is required.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13951 2 x 0,5 7,7 - 9,6 41,0 92,0 20 13957 2 x 0,75 8,0 - 10,0 46,0 102,0 19
13060 3 G 0,5 8,0 - 10,0 45,0 109,0 20 13072 3 G 0,75 8,3 - 10,4 57,0 115,0 19
13061 4 G 0,5 8,5 - 10,7 54,0 126,0 20 13073 4 G 0,75 9,1 - 11,3 63,0 150,0 19
13062 5 G 0,5 9,3 - 11,6 66,0 156,0 20 13074 5 G 0,75 9,7 - 12,1 76,0 173,0 19
13063 6 G 0,5 9,9 - 12,4 73,0 176,0 20 13075 6 G 0,75 10,5 - 13,1 82,0 195,0 19
13064 7 G 0,5 10,8 - 13,5 79,0 192,0 20 13076 7 G 0,75 11,5 - 14,3 100,0 235,0 19
13952 8 G 0,5 11,7 - 14,5 82,0 211,0 20 13958 8 G 0,75 12,1 - 15,0 112,0 268,0 19
13065 9 G 0,5 12,8 - 15,8 94,0 230,0 20 13077 9 G 0,75 13,3 - 16,5 130,0 285,0 19
13066 12 G 0,5 13,3 - 16,5 137,0 280,0 20 13078 12 G 0,75 13,9 - 17,2 175,0 327,0 19
13953 14 G 0,5 13,4 - 16,6 142,0 302,0 20 13959 14 G 0,75 14,4 - 17,7 190,0 362,0 19
13067 18 G 0,5 15,1 - 18,6 156,0 384,0 20 13079 18 G 0,75 16,2 - 19,9 240,0 488,0 19
13068 25 G 0,5 17,7 - 21,7 250,0 556,0 20 13080 25 G 0,75 18,7 - 22,6 306,0 654,0 19
13954 27 G 0,5 18,0 - 22,1 255,0 599,0 20 13960 27 G 0,75 19,3 - 23,7 326,0 708,0 19
13069 34 G 0,5 20,1 - 24,7 316,0 634,0 20 13081 34 G 0,75 21,3 - 26,2 346,0 821,0 19
13955 36 G 0,5 20,1 - 24,7 320,0 620,0 20 13961 36 G 0,75 21,3 - 26,2 358,0 899,0 19
13129 41 G 0,5 21,7 - 26,6 348,0 770,0 20 13130 41 G 0,75 23,1 - 28,3 403,0 970,0 19
13070 50 G 0,5 24,0 - 29,3 407,0 970,0 20 13082 50 G 0,75 25,3 - 31,0 470,0 1160,0 19
13071 61 G 0,5 25,5 - 31,1 520,0 1072,0 20 13083 61 G 0,75 27,0 - 32,9 550,0 1402,0 19
13956 65 G 0,5 26,1 - 31,9 563,0 1198,0 20 13962 65 G 0,75 27,8 - 34,0 594,0 1504,0 19
Continuation
57
Flexible Control Cables / PVC Control Cables
58
Flexible Control Cables / PVC Control Cables
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and
production lines.
These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants
and car washing stations.
These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.
The interconnection of parts of machines used for manufacturing purposes including machine tools where some degree of protection against
electromagnetic interference is required.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
13170 2x4 12,8 124,0 236,0 12 13190 3 G 16 23,0 653,0 993,0 6
13171 3G4 13,8 178,0 361,0 12 13191 4 G 16 25,2 807,0 1340,0 6
13172 4G4 14,9 234,0 430,0 12 13192 5 G 16 27,8 940,0 1626,0 6
13173 5G4 16,3 284,0 509,0 12 13193 7 G 16 33,9 1345,0 2080,0 6
13175 7G4 19,5 321,0 660,0 12 13196 4 G 25 30,7 1169,0 1692,0 4
13178 12 G 4 23,5 581,0 979,0 12 13197 5 G 25 34,1 1420,0 1972,0 4
13179 2x6 14,2 176,0 296,0 10 13198 3 G 35 31,0 1250,0 1704,0 2
13180 3G6 15,2 245,0 420,0 10 13199 4 G 35 34,1 1680,0 2320,0 2
13181 4G6 16,5 316,0 579,0 10 13189 5 G 35 37,3 2020,0 2780,0 2
13182 5G6 18,3 442,0 719,0 10 13194 3 G 50 35,7 1887,0 2661,0 1
13183 7G6 21,7 530,0 1031,0 10 13195 4 G 50 37,7 2370,0 3194,0 1
13185 3 G 10 18,8 367,0 655,0 8 13184 5 G 50 42,7 2880,0 4247,0 1
13186 4 G 10 20,7 549,0 894,0 8
13187 5 G 10 22,7 604,0 927,0 8
13188 7 G 10 27,8 820,0 1518,0 8
59
Flexible Control Cables / PVC Control Cables
Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning
and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burial- or as
underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back
a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath
is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. Interference-free transmission of signals and
pulses is assured by the high degree of screening.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11464 2 x 0,5 8,5 41,0 129,0 20 11516 2x1 9,2 54,0 150,0 18
11465 3 G 0,5 8,8 45,0 150,0 20 11517 3G1 9,8 64,0 163,0 18
11466 4 G 0,5 9,4 54,0 170,0 20 11518 4G1 10,4 76,0 200,0 18
11467 5 G 0,5 10,2 66,0 199,0 20 11519 5G1 11,4 89,0 239,0 18
11469 7 G 0,5 10,8 79,0 235,0 20 11521 7G1 12,3 114,0 289,0 18
11472 12 G 0,5 14,3 137,0 320,0 20 11525 12 G 1 15,9 186,0 464,0 18
11475 18 G 0,5 16,4 156,0 428,0 20 11528 18 G 1 18,2 284,0 628,0 18
11478 25 G 0,5 19,3 250,0 503,0 20 11532 25 G 1 22,0 387,0 855,0 18
11489 2 x 0,75 8,8 46,0 143,0 19 11546 2 x 1,5 10,4 64,0 162,0 16
11490 3 G 0,75 9,1 57,0 155,0 19 11547 3 G 1,5 10,8 82,0 187,0 16
11491 4 G 0,75 9,9 63,0 190,0 19 11548 4 G 1,5 11,5 99,0 240,0 16
11492 5 G 0,75 10,6 76,0 228,0 19 11549 5 G 1,5 13,0 123,0 289,0 16
11494 7 G 0,75 11,5 100,0 323,0 19 11551 7 G 1,5 14,2 148,0 383,0 16
11498 12 G 0,75 15,0 175,0 410,0 19 11556 12 G 1,5 18,4 274,0 592,0 16
11501 18 G 0,75 17,2 240,0 560,0 19 11559 18 G 1,5 21,3 386,0 806,0 16
11504 25 G 0,75 20,6 306,0 730,0 19 11563 25 G 1,5 25,4 531,0 1241,0 16
Continuation
60
Flexible Control Cables / PVC Control Cables
61
Flexible Control Cables / PVC Control Cables
Application
For use as a data and control cable in machinery, computer systems etc. as well as a signal cable for electronics. The high level of screening ensures a
high degree of interference protection. The screening density assures disturbance-free transmission of all signals and impulses. The PVC-inner sheaths
of those cables raise the mechanical stress. The applied clear transparent PVC outer sheath accentuates the optical view of the tinned copper braid.
These cables are suitable for flexible use for medium mechanical stresses with free movements. The dense screening assures disturbance-free transmission
of all signals and impulses. An ideal disturbance-free control cable for the above application.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
16121 2 x 0,5 7,0 41,0 67,0 20 16137 2 x 2,5 11,1 110,0 180,0 14
16122 3 G 0,5 7,3 45,0 83,0 20 16138 3 G 2,5 11,6 148,0 216,0 14
16123 4 G 0,5 7,9 54,0 94,0 20 16139 4 G 2,5 12,7 169,0 267,0 14
16124 5 G 0,5 8,4 66,0 108,0 20 16140 5 G 2,5 14,1 220,0 347,0 14
16125 2 x 0,75 7,7 46,0 87,0 19 16141 2x4 13,3 124,0 302,0 12
16126 3 G 0,75 8,0 57,0 98,0 19 16142 3G4 14,0 178,0 340,0 12
16127 4 G 0,75 8,5 63,0 113,0 19 16143 4G4 15,3 234,0 410,0 12
16128 5 G 0,75 9,3 76,0 130,0 19 16144 5G4 16,7 284,0 502,0 12
16129 2x1 8,0 54,0 97,0 18 16145 2x6 14,7 176,0 350,0 10
16130 3G1 8,3 64,0 103,0 18 16146 3G6 15,6 245,0 450,0 10
16131 4G1 9,0 76,0 146,0 18 16147 4G6 17,0 316,0 559,0 10
16132 5G1 9,7 89,0 169,0 18 16148 5G6 18,6 442,0 702,0 10
16133 2 x 1,5 8,6 64,0 130,0 16 16149 2 x 10 18,0 260,0 500,0 8
16134 3 G 1,5 9,2 82,0 152,0 16 16150 3 G 10 19,0 367,0 750,0 8
16135 4 G 1,5 9,8 99,0 168,0 16 16151 4 G 10 21,1 549,0 1020,0 8
16136 5 G 1,5 10,8 123,0 202,0 16 16152 5 G 10 23,1 604,0 1115,0 8
Continuation
62
Flexible Control Cables / PVC Control Cables
63
Flexible Control Cables / PVC Control Cables
SY-JB flexible, colour coded, with steel wire braiding, meter marking
Application
SY-JB cables are used as measuring and control cables in tool machinery, plant installation, power stations and in data equipment. The braided screen
offers best possible protection against mechanical damage. The galvanized coating on the steel wire braiding not only helps protect against corrosion,
but also notably improves the soldering performance.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12200 2 x 0,5 7,2 9,6 80,0 20 12277 2 x 2,5 10,2 48,0 185,0 14
12201 3 G 0,5 7,5 14,4 92,0 20 12278 3 G 2,5 10,9 72,0 248,0 14
12202 4 G 0,5 8,1 19,2 102,0 20 12279 4 G 2,5 11,6 96,0 290,0 14
12203 5 G 0,5 8,6 24,0 119,0 20 12280 5 G 2,5 12,9 120,0 347,0 14
12204 7 G 0,5 9,3 33,6 157,0 20 12281 7 G 2,5 14,2 168,0 420,0 14
12205 10 G 0,5 10,7 48,0 205,0 20 12282 12 G 2,5 17,7 288,0 660,0 14
12206 12 G 0,5 11,7 58,0 218,0 20 12291 2x4 13,6 77,0 330,0 12
12218 2 x 0,75 7,9 14,4 98,0 19 12318 3G4 14,3 115,0 375,0 12
12219 3 G 0,75 8,2 21,6 103,0 19 12292 4G4 15,4 154,0 428,0 12
12220 4 G 0,75 8,7 28,8 122,0 19 12293 5G4 16,9 192,0 504,0 12
12221 5 G 0,75 9,5 36,0 142,0 19 12294 7G4 18,4 269,0 640,0 12
12312 6 G 0,75 10,1 43,2 180,0 19 12295 3G6 15,6 173,0 543,0 10
12222 7 G 0,75 10,1 50,0 185,0 19 12296 4G6 17,0 230,0 571,0 10
12223 9 G 0,75 11,8 65,0 249,0 19 12297 5G6 18,6 288,0 671,0 10
12313 10 G 0,75 12,0 72,0 252,0 19 12298 7G6 20,6 403,0 845,0 10
12224 12 G 0,75 12,8 86,0 292,0 19 12319 3 G 10 19,2 288,0 735,0 8
12234 2x1 8,2 19,2 112,0 18 12299 4 G 10 21,1 384,0 943,0 8
12235 3G1 8,5 28,8 132,0 18 12300 5 G 10 23,3 480,0 1065,0 8
12236 4G1 9,2 38,4 143,0 18 12301 7 G 10 25,4 672,0 1551,0 8
12237 5G1 9,9 48,0 166,0 18 12320 3 G 16 23,0 461,0 1080,0 6
12238 6G1 10,5 58,0 220,0 18 12302 4 G 16 25,5 614,0 1360,0 6
12239 7G1 10,5 67,0 227,0 18 12303 5 G 16 28,2 768,0 1740,0 6
12240 8G1 11,4 77,0 277,0 18 12304 7 G 16 30,8 1075,0 2166,0 6
12241 9G1 12,8 86,0 295,0 18 12321 3 G 25 28,2 720,0 1630,0 4
12242 12 G 1 13,4 115,0 340,0 18 12305 4 G 25 31,0 960,0 2020,0 4
12256 2 x 1,5 8,8 29,0 129,0 16 12306 5 G 25 34,3 1200,0 2465,0 4
12257 3 G 1,5 9,4 43,0 149,0 16 12322 3 G 35 31,0 1008,0 1932,0 2
12258 4 G 1,5 10,0 58,0 185,0 16 12307 4 G 35 34,0 1344,0 2570,0 2
12259 5 G 1,5 10,9 72,0 205,0 16 12308 5 G 35 38,0 1680,0 3185,0 2
12260 6 G 1,5 11,8 87,0 255,0 16 12323 3 G 50 36,7 1440,0 2679,0 1
12261 7 G 1,5 11,8 101,0 285,0 16 12309 4 G 50 40,4 1920,0 3513,0 1
12262 8 G 1,5 12,7 115,0 340,0 16 12314 5 G 50 45,2 2400,0 4248,0 1
12263 9 G 1,5 13,9 130,0 347,0 16 12324 3 G 70 42,3 2016,0 2790,0 2/0
12264 10 G 1,5 14,3 144,0 418,0 16 12310 4 G 70 46,2 2688,0 4810,0 2/0
12265 11 G 1,5 14,8 158,0 430,0 16 12315 5 G 70 50,5 3360,0 5880,0 2/0
12266 12 G 1,5 15,0 173,0 444,0 16
Continuation
64
Flexible Control Cables / PVC Control Cables
SY-JB flexible, colour coded, with steel wire braiding, meter marking
65
PUR CONTROL CABLES
66
Flexible Control Cables / PUR Control Cables
Application
JZ-500 PUR is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance coolant emulsions, it is
especially suited for use in the machine, tool making and plant industries as well as in the steel industry for difficult and problem areas. The high
flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
23314 2 x 0,5 4,8 9,6 45,0 20 23352 7x1 8,1 67,0 115,0 18
23315 3 G 0,5 5,1 14,4 55,0 20 23353 10 G 1 9,8 96,0 166,0 18
23316 3 x 0,5 5,1 14,4 55,0 20 23354 12 G 1 10,4 115,0 201,0 18
23317 4 G 0,5 5,5 19,0 65,0 20 23355 18 G 1 12,9 173,0 289,0 18
23318 4 x 0,5 5,5 19,0 65,0 20 23356 25 G 1 15,4 240,0 380,0 18
23319 5 G 0,5 6,2 24,0 75,0 20 23357 34 G 1 17,7 326,0 645,0 18
23320 5 x 0,5 6,2 24,0 75,0 20 23358 42 G 1 19,5 403,0 730,0 18
23321 7 G 0,5 6,7 33,6 90,0 20 23359 50 G 1 21,3 480,0 890,0 18
23322 7 x 0,5 6,7 33,6 90,0 20 23360 2 x 1,5 6,4 29,0 68,0 16
23323 10 G 0,5 8,3 48,0 120,0 20 23361 3 G 1,5 6,8 43,0 87,0 16
23324 12 G 0,5 8,7 58,0 135,0 20 23362 3 x 1,5 6,8 43,0 87,0 16
23325 18 G 0,5 10,7 86,0 205,0 20 23363 4 G 1,5 7,4 58,0 106,0 16
23326 25 G 0,5 12,6 120,0 270,0 20 23364 4 x 1,5 7,4 58,0 106,0 16
23327 34 G 0,5 14,3 163,0 380,0 20 23365 5 G 1,5 8,3 72,0 131,0 16
23328 42 G 0,5 15,8 202,0 415,0 20 23366 5 x 1,5 8,3 72,0 131,0 16
23329 2 x 0,75 5,3 14,4 44,0 19 23367 7 G 1,5 9,2 101,0 173,0 16
23330 3 G 0,75 5,6 21,6 53,0 19 23368 7 x 1,5 9,2 101,0 173,0 16
23331 3 x 0,75 5,6 21,6 53,0 19 23369 12 G 1,5 11,8 173,0 293,0 16
23332 4 G 0,75 6,3 29,0 64,0 19 23370 18 G 1,5 14,6 259,0 454,0 16
23333 4 x 0,75 6,3 29,0 64,0 19 23371 25 G 1,5 17,4 360,0 641,0 16
23334 5 G 0,75 6,9 36,0 76,0 19 23372 30 G 1,5 18,6 410,0 800,0 16
23335 5 x 0,75 6,9 36,0 76,0 19 23373 2 x 2,5 7,8 48,0 110,0 14
23336 7 G 0,75 7,5 50,0 96,0 19 23374 3 G 2,5 8,3 72,0 146,0 14
23337 7 x 0,75 7,5 50,0 96,0 19 23375 4 G 2,5 9,2 96,0 183,0 14
23338 10 G 0,75 9,2 72,0 140,0 19 23376 5 G 2,5 10,1 120,0 222,0 14
23339 12 G 0,75 9,8 86,0 170,0 19 23377 7 G 2,5 11,2 168,0 293,0 14
23340 18 G 0,75 12,2 130,0 260,0 19 23378 12 G 2,5 14,8 288,0 512,0 14
23341 25 G 0,75 14,3 180,0 282,0 19 23379 4G4 10,9 154,0 291,0 12
23342 34 G 0,75 16,5 245,0 475,0 19 23380 5G4 12,1 192,0 355,0 12
23343 42 G 0,75 18,1 302,0 600,0 19 23381 7G4 13,2 269,0 503,0 12
23344 2x1 5,6 19,0 53,0 18 23382 4G6 13,0 230,0 468,0 10
23345 3G1 5,6 29,0 63,0 18 23383 5G6 14,5 288,0 570,0 10
23346 3x1 5,9 29,0 63,0 18 23384 7G6 16,2 403,0 808,0 10
23347 4G1 6,6 38,0 75,0 18 23385 4 G 10 16,5 384,0 720,0 8
23348 4x1 6,6 38,0 75,0 18 23386 5 G 10 18,3 480,0 894,0 8
23349 5G1 7,3 48,0 89,0 18 23387 7 G 10 20,2 672,0 1295,0 8
23350 5x1 7,3 48,0 89,0 18 23388 4 G 16 20,1 614,0 1063,0 6
23351 7G1 8,1 67,0 115,0 18
67
Flexible Control Cables / PUR Control Cables
PUR-JZ tear and coolant resistant, increased oil resistant, meter marking
Application
PUR-JZ is an extremely robust control cable with high abrasion and tear resistant properties. With high-grade oil resistant PVC core insulation. Due
to its high resistance to mineral oils and especially to coolant emulsions, it is especially suited for use in the machine, tool making, plant construction
as well as in the steel industry for difficult and problem areas. For medium mechanical stress for flexible use with free movement without tensile stress
or forced movements in dry, damp and wet rooms and in open air. The high flexibility of this cable type makes it quick and easy to install.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22100 2 x 0,5 4,8 9,6 45,0 20 22132 2x1 5,6 19,0 53,0 18
22101 3 G 0,5 5,1 14,4 55,0 20 22133 3G1 5,9 29,0 63,0 18
22102 4 G 0,5 5,5 19,0 65,0 20 22134 4G1 6,6 38,0 75,0 18
22103 5 G 0,5 6,2 24,0 75,0 20 22135 5G1 7,3 48,0 89,0 18
22104 7 G 0,5 6,7 33,6 90,0 20 22136 7G1 8,1 67,0 115,0 18
22105 8 G 0,5 7,4 38,0 105,0 20 22137 8G1 8,8 77,0 131,0 18
22106 10 G 0,5 8,3 48,0 120,0 20 22138 10 G 1 9,8 96,0 166,0 18
22107 12 G 0,5 8,7 58,0 135,0 20 22139 12 G 1 10,4 115,0 201,0 18
22108 14 G 0,5 9,5 67,0 170,0 20 22140 14 G 1 11,4 134,0 230,0 18
22109 18 G 0,5 10,7 86,0 205,0 20 22141 18 G 1 12,9 173,0 289,0 18
22110 21 G 0,5 11,3 96,0 225,0 20 22142 21 G 1 13,8 196,0 306,0 18
22111 25 G 0,5 12,6 120,0 270,0 20 22143 25 G 1 15,4 240,0 380,0 18
22112 30 G 0,5 13,5 144,0 315,0 20 22144 32 G 1 17,1 308,0 620,0 18
22113 34 G 0,5 14,3 163,0 380,0 20 22145 34 G 1 17,7 326,0 645,0 18
22114 42 G 0,5 15,8 202,0 415,0 20 22146 42 G 1 19,5 403,0 730,0 18
22115 50 G 0,5 17,5 240,0 550,0 20 22147 50 G 1 21,3 480,0 890,0 18
22116 2 x 0,75 5,3 14,4 44,0 19 22148 2 x 1,5 6,4 29,0 68,0 16
22117 3 G 0,75 5,6 21,6 53,0 19 22149 3 G 1,5 6,8 43,0 87,0 16
22118 4 G 0,75 6,3 29,0 64,0 19 22150 4 G 1,5 7,4 58,0 106,0 16
22119 5 G 0,75 6,9 36,0 76,0 19 22151 5 G 1,5 8,3 72,0 131,0 16
22120 7 G 0,75 7,5 50,0 96,0 19 22152 7 G 1,5 9,2 101,0 173,0 16
22121 8 G 0,75 8,3 58,0 111,0 19 22153 8 G 1,5 10,0 115,0 199,0 16
22122 10 G 0,75 9,2 72,0 140,0 19 22154 10 G 1,5 10,9 144,0 245,0 16
22123 12 G 0,75 9,8 86,0 170,0 19 22155 12 G 1,5 11,8 173,0 293,0 16
22124 14 G 0,75 10,6 101,0 202,0 19 22156 14 G 1,5 13,0 202,0 347,0 16
22125 18 G 0,75 12,2 130,0 260,0 19 22157 18 G 1,5 14,6 259,0 454,0 16
22126 21 G 0,75 12,7 151,0 269,0 19 22158 21 G 1,5 15,6 302,0 534,0 16
22127 25 G 0,75 14,3 180,0 282,0 19 22159 25 G 1,5 17,4 360,0 641,0 16
22128 30 G 0,75 15,3 216,0 400,0 19 22160 30 G 1,5 18,6 410,0 800,0 16
22129 34 G 0,75 16,5 245,0 475,0 19 22161 34 G 1,5 20,0 490,0 945,0 16
22130 42 G 0,75 18,1 302,0 600,0 19 22162 42 G 1,5 21,8 605,0 1100,0 16
22131 50 G 0,75 19,8 360,0 720,0 19 22163 50 G 1,5 24,2 720,0 1250,0 16
Continuation
68
Flexible Control Cables / PUR Control Cables
PUR-JZ tear and coolant resistant, increased oil resistant, meter marking
69
Flexible Control Cables / PUR Control Cables
Application
Robust control cable with an outstanding resistance to oil and abrasion. Suitable for use in tool making and machine industries, steel works, on building
sites and in the oil and coal industries. The cable can also be used for portable tools etc. To be recommended if the cable comes into contact with
chemical agents.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
JZ/OZ-version: cores numbered JB/OB-version: cores colour coded
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22001 2 x 0,75 6,4 14,4 50,0 19 22250 2 x 0,75 6,4 14,4 50,0 19
22002 3 G 0,75 6,8 21,6 70,0 19 22251 3 G 0,75 6,8 21,6 70,0 19
22003 4 G 0,75 7,3 28,8 80,0 19 22252 4 G 0,75 7,3 28,8 80,0 19
22004 5 G 0,75 8,2 36,0 100,0 19 22253 5 G 0,75 8,2 36,0 100,0 19
22005 7 G 0,75 9,2 50,0 140,0 19 22254 2x1 7,2 19,2 63,0 18
22006 2x1 7,2 19,2 63,0 18 22255 3G1 7,6 29,0 76,0 18
22007 3G1 7,6 29,0 76,0 18 22256 4G1 8,0 38,0 95,0 18
22008 4G1 8,0 38,0 95,0 18 22257 5G1 8,8 48,0 120,0 18
22009 5G1 8,8 48,0 120,0 18 22258 2 x 1,5 7,8 29,0 80,0 16
22010 7G1 10,0 67,0 170,0 18 22259 3 G 1,5 8,3 43,0 105,0 16
22015 2 x 1,5 7,8 29,0 80,0 16 22260 4 G 1,5 9,0 58,0 135,0 16
22016 3 G 1,5 8,3 43,0 105,0 16 22261 5 G 1,5 9,7 72,0 158,0 16
22017 4 G 1,5 9,0 58,0 135,0 16 22262 2 x 2,5 9,2 48,0 150,0 14
22018 5 G 1,5 9,7 72,0 158,0 16 22263 3 G 2,5 9,6 72,0 173,0 14
22019 7 G 1,5 11,2 101,0 221,0 16 22264 4 G 2,5 11,0 96,0 203,0 14
22025 2 x 2,5 9,2 48,0 150,0 14 22265 5 G 2,5 12,0 120,0 253,0 14
22026 3 G 2,5 9,6 72,0 173,0 14 22266 4G4 13,2 154,0 300,0 12
22027 4 G 2,5 11,0 96,0 203,0 14 22267 5G4 14,8 192,0 370,0 12
22028 5 G 2,5 12,0 120,0 253,0 14 22268 4G6 15,4 230,0 480,0 10
22029 7 G 2,5 13,7 168,0 356,0 14 22269 5G6 17,0 288,0 583,0 10
22033 3G4 11,8 115,0 250,0 12 22270 4 G 10 20,8 384,0 740,0 8
22034 4G4 13,2 154,0 300,0 12 22271 5 G 10 22,6 480,0 920,0 8
22035 5G4 14,8 192,0 370,0 12 22272 4 G 16 23,0 614,0 1100,0 6
22036 7G4 16,4 269,0 500,0 12 22273 5 G 16 27,4 768,0 1400,0 6
22037 4G6 15,4 230,0 480,0 10 22044 4 G 25 30,0 960,0 1600,0 4
22038 5G6 17,0 288,0 583,0 10 22045 5 G 25 32,2 1200,0 2000,0 4
22039 7G6 20,8 403,0 780,0 10 22046 4 G 35 33,0 1344,0 2100,0 2
22040 4 G 10 20,8 384,0 740,0 8
22041 5 G 10 22,6 480,0 920,0 8
22042 4 G 16 23,0 614,0 1100,0 6
22043 5 G 16 27,4 768,0 1400,0 6
70
Flexible Control Cables / PUR Control Cables
Application
Robust control cable with an outstanding resistance to oil and abrasion. Suitable for use in tool making and machine industries, steel works, on building
sites and in the oil and coal industries. The cable can also be used for portable tools. etc. To be recommended if the cable comes into contact with
chemical agents.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22200 2 x 0,75 6,4 14,4 50,0 19 22212 4 G 1,5 9,0 58,0 135,0 16
22201 3 G 0,75 6,8 21,6 70,0 19 22220 4 G 1,5 9,7 58,0 135,0 16
22202 4 G 0,75 7,3 28,8 80,0 19 22213 5 G 1,5 11,2 72,0 158,0 16
22203 5 G 0,75 8,2 36,0 100,0 19 22214 7 G 1,5 9,2 101,0 221,0 16
22204 7 G 0,75 9,2 50,0 140,0 19 22215 2 x 2,5 9,6 48,0 150,0 14
22205 2x1 7,2 19,2 63,0 18 22216 3 G 2,5 11,0 72,0 173,0 14
22206 3G1 7,6 29,0 76,0 18 22217 4 G 2,5 12,0 96,0 203,0 14
22207 4G1 8,0 38,0 95,0 18 22218 5 G 2,5 13,7 120,0 253,0 14
22208 5G1 8,8 48,0 120,0 18 22219 7 G 2,5 9,0 168,0 356,0 14
22209 7G1 10,0 67,0 170,0 18 22221 4G4 14,6 153,6 310,0 12
22210 2 x 1,5 7,8 29,0 80,0 16 22222 5G4 14,8 192,0 370,0 12
22211 3 G 1,5 8,3 43,0 105,0 16 22233 4 G 35 33,0 1344,0 2100,0 2
71
Flexible Control Cables / PUR Control Cables
Application
These cables can be used for medium mechanical loads in dry, damp or wet environments, e. g. for connecting agricultural and commercial equipment
and heaters provided there is no danger of contact with the hot parts or by radiation of heat. These robust and flexible cables are used for electrical
tools such as drills and hand-held circular saws, as well as for portable motors and machinery in agriculture, at building sites, docks and refrigeration
plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05BQ-F H07BQ-F
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. *) No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
22050 2 x 0,75 5,7 - 7,4 14,4 52,0 19 22074 220974 2 x 10 15,6 - 19,9 192,0 428,0 8
22051 3 G 0,75 6,2 - 8,1 21,6 63,0 19 22076 220976 3 G 10 16,8 - 21,4 288,0 640,0 8
22052 4 G 0,75 6,8 - 8,8 29,0 80,0 19 22078 220978 4 G 10 18,6 - 23,6 384,0 738,0 8
22053 5 G 0,75 7,6 - 9,9 36,0 96,0 19 22082 220982 5 G 10 20,4 - 25,9 480,0 968,0 8
22054 2x1 6,1 - 8,0 19,2 59,0 18 22075 220975 2 x 16 17,9 - 22,8 307,0 600,0 6
22055 3G1 6,5 - 8,5 29,0 71,0 18 22077 220977 3 G 16 19,5 - 24,7 461,0 758,0 6
22056 4G1 7,1 - 9,3 38,4 89,0 18 22079 220979 4 G 16 21,3 - 27,0 614,0 1187,0 6
22057 5G1 8,0 - 10,3 48,0 112,0 18 22083 220983 5 G 16 23,7 - 30,0 768,0 1475,0 6
22828 228928 4 G 25 26,7 - 32,6 960,0 1550,0 4
H07BQ-F 22829 228929 5 G 25 29,6 - 36,1 1220,0 1920,0 4
Part no. *) No.cores x Outer Cop. Weight AWG-No. 22830 228930 4 G 35 31,3 - 38,2 1344,0 2120,0 2
cross-sec. min. - max. weight approx. 22831 228931 5 G 35 34,5 - 42,0 1680,0 2600,0 2
mm mm kg / km kg / km 22832 228932 4 G 50 34,9 - 42,6 1920,0 2920,0 1
22058 220958 2 x 1,5 7,6 - 9,8 29,0 92,0 16 22833 228933 5 G 50 38,6 - 47,0 2400,0 3700,0 1
22059 220959 3 G 1,5 8,0 - 10,4 43,0 109,0 16 22835 228935 4 G 70 38,9 - 47,3 2688,0 3900,0 2/0
22060 220960 4 G 1,5 9,0 - 11,6 58,0 145,0 16 22836 228936 5 G 70 43,0 - 52,3 3368,0 5020,0 2/0
22061 220961 5 G 1,5 9,8 - 12,7 72,0 169,0 16 22837 228937 4 G 95 44,9 - 54,6 3648,0 5150,0 3/0
22062 220962 7 G 1,5 12,2 - 15,1 101,0 230,0 16 22838 228938 5 G 95 49,7 - 60,4 4560,0 6520,0 3/0
22063 220963 12 G 1,5 15,0 - 18,4 173,0 398,0 16 22839 228939 4 G 120 47,9 - 58,2 4608,0 6550,0 4/0
22064 220964 2 x 2,5 9,0 - 11,6 48,0 121,0 14 22840 228940 5 G 120 53,1 - 64,5 5760,0 8050,0 4/0
22065 220965 3 G 2,5 9,6 - 12,4 72,0 164,0 14 22841 228941 4 G 150 53,5 - 65,0 5760,0 7950,0 300 kcmil
22066 220966 4 G 2,5 10,7 - 13,8 96,0 207,0 14 22842 228942 5 G 185 65,6 - 79,6 7104,0 9350,0 350 kcmil
22067 220967 5 G 2,5 11,9 - 16,3 120,0 262,0 14 22843 228943 4 G 240 68,1 - 82,6 9216,0 12200,0 500 kcmil
22072 220972 2x4 10,6 - 13,7 77,0 194,0 12
22068 220968 3G4 11,3 - 14,5 115,0 224,0 12
22069 220969 4G4 12,7 - 16,2 154,0 327,0 12
22080 220980 5G4 14,1 - 17,9 192,0 415,0 12
22073 220973 2x6 11,8 - 15,1 115,0 311,0 10
22070 220970 3G6 12,8 - 16,3 173,0 310,0 10
22071 220971 4G6 14,2 - 18,1 230,0 496,0 10
22081 220981 5G6 15,7 - 20,0 288,0 586,0 10
72
Flexible Control Cables / PUR Control Cables
Application
These robust and flexible cables are used for electrical tools such as drills, hand-held circular saws, and garden equipment as well as for portable
motors and machinery in agriculture, at building sites, for hobbies, docks and refrigeration plants.
Extremely good mechanical characteristies e. g. compressive load, good abrasion and near-resistant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
1812x 2 x 0,5 5,8 9,6 40,0 20 1822x 2 x 0,75 6,3 14,0 52,0 19
1813x 3 G 0,5 6,1 14,4 47,0 20 1823x 3 G 0,75 6,9 21,6 62,0 19
1814x 4 G 0,5 6,7 19,0 57,0 20 1824x 4 G 0,75 7,5 28,8 80,0 19
1815x 5 G 0,5 7,5 24,0 65,0 20 1825x 5 G 0,75 8,3 36,0 94,0 19
1816x 7 G 0,5 9,0 33,6 94,0 20 1826x 6 G 0,75 9,0 43,0 111,0 19
1817x 12 G 0,5 10,7 58,0 150,0 20 1827x 7 G 0,75 9,8 50,0 160,0 19
1818x 18 G 0,5 13,0 86,0 208,0 20 1828x 12 G 0,75 11,6 86,0 191,0 19
1819x 25 G 0,5 15,6 120,0 276,0 20 1829x 18 G 0,75 14,1 130,0 267,0 19
1820x 34 G 0,5 17,9 163,0 393,0 20 1830x 25 G 0,75 17,0 180,0 376,0 19
1821x 41 G 0,5 19,6 197,0 460,0 20 1831x 34 G 0,75 19,5 245,0 506,0 19
1832x 41 G 0,75 21,2 296,0 596,0 19
Continuation
73
Flexible Control Cables / PUR Control Cables
74
Flexible Control Cables / PUR Control Cables
Application
Especially suited for installation in all areas demanding good performance under extreme conditions. These cable types have been successfully in use
in areas such as steel works, heating and air-conditioning systems, in machinery and industrial plant equipment and on building sites etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49700 2 x 0,75 6,3 15,0 44,0 19 49739 18 G 2,5 23,0 432,0 778,0 14
49701 3 G 0,75 6,8 22,0 55,0 19 49740 20 G 2,5 24,4 480,0 860,0 14
49702 4 G 0,75 7,4 29,0 70,0 19 49741 25 G 2,5 28,5 600,0 1083,0 14
49703 5 G 0,75 8,3 36,0 91,0 19 49742 3G4 12,2 115,0 220,0 12
49704 7 G 0,75 9,7 50,0 130,0 19 49743 4G4 13,4 154,0 280,0 12
49705 12 G 0,75 12,1 86,0 192,0 19 49744 5G4 15,1 192,0 350,0 12
49706 18 G 0,75 14,2 130,0 290,0 19 49745 7G4 18,2 269,0 470,0 12
49707 25 G 0,75 17,6 180,0 405,0 19 49746 4G6 15,8 230,0 400,0 10
49708 2x1 6,8 20,0 50,0 18 49747 5G6 17,3 288,0 500,0 10
49709 3G1 7,2 29,0 65,0 18 49748 7G6 21,0 403,0 700,0 10
49710 4G1 7,8 38,0 87,0 18 49749 4 G 10 20,4 384,0 640,0 8
49711 5G1 8,8 48,0 106,0 18 49750 5 G 10 22,5 480,0 800,0 8
49712 6G1 9,5 58,0 135,0 18 49751 7 G 10 26,6 672,0 1180,0 8
49713 7G1 10,4 67,0 160,0 18 49752 4 G 16 23,3 614,0 920,0 6
49714 8G1 11,4 77,0 185,0 18 49753 5 G 16 25,9 768,0 1180,0 6
49715 10 G 1 12,8 96,0 210,0 18 49754 4 G 25 27,3 960,0 1400,0 4
49716 12 G 1 12,8 115,0 240,0 18 49755 5 G 25 30,4 1200,0 1740,0 4
49717 16 G 1 14,4 154,0 310,0 18 49756 4 G 35 31,0 1344,0 1870,0 2
49718 18 G 1 15,3 173,0 353,0 18 49757 5 G 35 34,8 1680,0 2320,0 2
49719 20 G 1 16,4 192,0 390,0 18 49758 4 G 50 36,8 1920,0 2700,0 1
49720 25 G 1 18,8 240,0 495,0 18 49759 5 G 50 41,2 2400,0 3300,0 1
49721 2 x 1,5 8,2 29,0 70,0 16 49760 4 G 70 43,2 2688,0 3700,0 2/0
49722 3 G 1,5 8,7 43,0 95,0 16 49761 5 G 70 48,2 3660,0 4900,0 2/0
49723 4 G 1,5 9,7 58,0 120,0 16 49918 4 G 95 48,7 3648,0 4850,0 3/0
49724 5 G 1,5 10,6 72,0 164,0 16 49762 5 G 95 54,5 4560,0 6000,0 3/0
49725 7 G 1,5 12,8 101,0 210,0 16 49763 4 G 120 54,9 4610,0 6005,0 4/0
49726 10 G 1,5 15,8 150,0 290,0 16
49727 12 G 1,5 15,8 172,0 340,0 16
49728 16 G 1,5 17,9 230,0 440,0 16
49729 18 G 1,5 18,8 259,0 508,0 16
49730 20 G 1,5 20,0 300,0 560,0 16
49731 25 G 1,5 23,5 360,0 722,0 16
49732 2 x 2,5 9,8 48,0 110,0 14
49733 3 G 2,5 10,5 72,0 150,0 14
49734 4 G 2,5 11,6 96,0 180,0 14
49735 5 G 2,5 13,0 120,0 240,0 14
49736 7 G 2,5 15,5 168,0 340,0 14
49737 12 G 2,5 19,3 288,0 520,0 14
49738 16 G 2,5 21,6 394,0 680,0 14
75
Flexible Control Cables / PUR Control Cables
Application
Extremely robust cable noted for its good abrasion resistance and notch resistance. Due to its resistance to coolant emulsions, this cable is well suited
for use in mechanical engineering, tool making, and systems engineering, and in steel mills and rolling mills in particularly critical areas. Good flexibility
means that installation is quick and easy. Suitable for medium mechanical stresses with free movement without tensile stress or forced movements in
dry, moist and wet rooms, and in open air (fixed installation). The dense screening assures interference-free transmission of all signals and impulses.
An ideal interference-free control cable for the above applications.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
23414 2 x 0,5 5,7 35,0 47,0 20 23429 2 x 0,75 6,1 40,0 60,0 19
23415 3 G 0,5 5,9 42,0 57,0 20 23430 3 G 0,75 6,3 52,0 67,0 19
23416 3 x 0,5 5,9 42,0 57,0 20 23431 3 x 0,75 6,3 52,0 67,0 19
23417 4 G 0,5 6,4 47,0 60,0 20 23432 4 G 0,75 6,8 60,0 76,0 19
23418 4 x 0,5 6,4 47,0 60,0 20 23433 4 x 0,75 6,8 60,0 76,0 19
23419 5 G 0,5 6,9 56,0 75,0 20 23435 5 x 0,75 7,4 71,0 92,0 19
23420 5 x 0,5 6,9 56,0 75,0 20 23434 5 G 0,75 7,4 71,0 92,0 19
23421 7 G 0,5 7,6 69,0 97,0 20 23437 7 x 0,75 8,2 91,0 131,0 19
23422 7 x 0,5 7,6 69,0 97,0 20 23436 7 G 0,75 8,2 91,0 131,0 19
23423 10 G 0,5 9,6 94,0 133,0 20 23438 10 G 0,75 10,3 137,0 180,0 19
23424 12 G 0,5 9,7 108,0 158,0 20 23439 12 G 0,75 10,5 142,0 204,0 19
23425 18 G 0,5 11,5 145,0 218,0 20 23440 18 G 0,75 12,7 212,0 290,0 19
23426 25 G 0,5 13,7 240,0 315,0 20 23441 25 G 0,75 15,0 281,0 413,0 19
23427 34 G 0,5 15,5 312,0 420,0 20 23442 34 G 0,75 17,2 345,0 492,0 19
23428 42 G 0,5 16,9 355,0 487,0 20 23443 42 G 0,75 18,8 407,0 624,0 19
Continuation
76
Flexible Control Cables / PUR Control Cables
77
Flexible Control Cables / PUR Control Cables
F-C-PUR-JZ tear and coolant resistant, Cu-screened, without inner sheath, increased
oil resistant, EMC-preferred type, meter marking
Application
Extremely robust control cable characterised by high abrasion and notch resistance properties. Used for critical areas in such applications as machinery,
tooling and plant construction, in rolling mills and steel works because of the resistance to mineral oils and to coolant emulsions in particular. Rapid
and safe installation assured by the good flexibility of the cable. Suitable for outdoor installation.
An interference-free transmission of signals and pulses is assured by the high screening density. The ideal interference-protected control cable for
such applications as given above.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21200 2 x 0,5 5,7 35,0 44,0 20 21227 2 x 0,75 6,1 40,0 60,0 19
21201 3 G 0,5 5,9 42,0 56,0 20 21228 3 G 0,75 6,3 52,0 67,0 19
21202 4 G 0,5 6,4 47,0 60,0 20 21229 4 G 0,75 6,8 60,0 76,0 19
21203 5 G 0,5 6,9 56,0 75,0 20 21230 5 G 0,75 7,4 71,0 92,0 19
21205 7 G 0,5 7,6 69,0 97,0 20 21232 7 G 0,75 8,2 91,0 131,0 19
21207 10 G 0,5 9,6 94,0 133,0 20 21234 10 G 0,75 10,3 137,0 180,0 19
21208 12 G 0,5 9,7 108,0 158,0 20 21235 12 G 0,75 10,5 142,0 204,0 19
21209 14 G 0,5 10,2 116,0 190,0 20 21236 14 G 0,75 11,3 180,0 226,0 19
21211 18 G 0,5 11,5 145,0 218,0 20 21238 18 G 0,75 12,7 212,0 290,0 19
21213 21 G 0,5 12,3 188,0 252,0 20 21240 21 G 0,75 13,6 246,0 376,0 19
21215 25 G 0,5 13,7 240,0 315,0 20 21242 25 G 0,75 15,0 281,0 413,0 19
21217 30 G 0,5 14,4 295,0 362,0 20 21245 32 G 0,75 16,7 342,0 485,0 19
21220 36 G 0,5 15,6 318,0 447,0 20 21249 41 G 0,75 18,2 400,0 611,0 19
21221 40 G 0,5 16,4 343,0 475,0 20 21251 50 G 0,75 20,3 461,0 775,0 19
21224 50 G 0,5 18,5 406,0 572,0 20
Continuation
78
Flexible Control Cables / PUR Control Cables
F-C-PUR-JZ tear and coolant resistant, Cu-screened, without inner sheath, increased
oil resistant, EMC-preferred type, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21253 2x1 6,4 50,0 66,0 18 21290 14 G 1,5 13,5 283,0 384,0 16
21254 3G1 6,7 60,0 82,0 18 21291 16 G 1,5 14,6 315,0 425,0 16
21255 4G1 7,2 71,0 100,0 18 21292 18 G 1,5 15,6 374,0 480,0 16
21256 5G1 8,0 88,0 128,0 18 21295 21 G 1,5 16,6 425,0 563,0 16
21257 6G1 8,7 97,0 145,0 18 21296 25 G 1,5 18,5 526,0 704,0 16
21258 7G1 8,7 111,0 157,0 18 21297 34 G 1,5 21,2 629,0 870,0 16
21259 8G1 9,6 127,0 198,0 18 21298 42 G 1,5 22,2 819,0 1040,0 16
21261 10 G 1 11,2 150,0 230,0 18 21299 50 G 1,5 25,0 885,0 1292,0 16
21262 12 G 1 11,4 184,0 262,0 18 21300 2 x 2,5 8,4 96,0 131,0 14
21263 14 G 1 12,0 196,0 302,0 18 21301 3 G 2,5 8,8 144,0 168,0 14
21264 16 G 1 12,8 209,0 345,0 18 21302 4 G 2,5 9,8 148,0 194,0 14
21265 18 G 1 13,6 260,0 381,0 18 21303 5 G 2,5 10,8 181,0 222,0 14
21267 21 G 1 14,3 319,0 480,0 18 21304 7 G 2,5 11,9 255,0 345,0 14
21268 25 G 1 16,2 349,0 535,0 18 21305 10 G 2,5 15,5 340,0 462,0 14
21273 34 G 1 18,5 486,0 740,0 18 21306 12 G 2,5 15,8 441,0 570,0 14
21276 41 G 1 19,5 531,0 855,0 18 21313 2x4 10,0 120,0 187,0 12
21278 50 G 1 22,0 625,0 1027,0 18 21314 3G4 10,6 174,0 243,0 12
21280 2 x 1,5 7,0 63,0 87,0 16 21315 4G4 11,6 230,0 310,0 12
21281 3 G 1,5 7,4 80,0 102,0 16 21316 5G4 12,8 273,0 386,0 12
21282 4 G 1,5 8,1 97,0 127,0 16 21317 7G4 14,2 316,0 498,0 12
21283 5 G 1,5 9,0 119,0 159,0 16 21319 3G6 12,5 240,0 333,0 10
21285 7 G 1,5 9,8 147,0 207,0 16 21320 4G6 13,8 305,0 414,0 10
21286 8 G 1,5 10,8 170,0 245,0 16 21321 5G6 15,4 439,0 510,0 10
21287 10 G 1,5 12,6 193,0 313,0 16 21322 7G6 17,0 505,0 673,0 10
21288 12 G 1,5 12,8 267,0 340,0 16
79
Flexible Control Cables / PUR Control Cables
Y-C-PUR-JZ tear and coolant resistant, Cu-screened, with inner sheath, increased
oil resistant, EMC-preferred type, meter marking
Application
Extremely robust control cable characterised by high abrasion and notch resistance properties. Used for critical areas in such applications as machinery,
tooling and plant construction, in rolling mills and steel works because of the resistance to mineral oils and to coolant emulsions in particular. The
mechanical strength of the cable is increased by the additional oil-resistant inner sheath. The ideal interference-protected control cable for such
applications as given above. Suitable for outdoor installation.
These screened cables are particularly suitable for the interference-free transmission in instrumentation and control engineering applications
(electromagnetic compatibillity).
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21400 2 x 0,5 7,0 41,0 68,0 20 21425 2 x 0,75 7,7 46,0 88,0 19
21401 3 G 0,5 7,3 45,0 84,0 20 21426 3 G 0,75 8,0 57,0 98,0 19
21402 4 G 0,5 7,9 54,0 95,0 20 21427 4 G 0,75 8,5 63,0 112,0 19
21403 5 G 0,5 8,4 66,0 107,0 20 21428 5 G 0,75 9,3 76,0 130,0 19
21405 7 G 0,5 9,1 79,0 135,0 20 21430 7 G 0,75 9,9 100,0 185,0 19
21407 10 G 0,5 10,7 107,0 170,0 20 21432 10 G 0,75 11,8 140,0 270,0 19
21408 12 G 0,5 11,5 137,0 195,0 20 21433 12 G 0,75 12,7 175,0 294,0 19
21409 14 G 0,5 12,2 142,0 222,0 20 21434 14 G 0,75 13,3 190,0 317,0 19
21411 18 G 0,5 13,5 156,0 278,0 20 21436 18 G 0,75 14,9 240,0 357,0 19
21413 21 G 0,5 14,2 189,0 330,0 20 21438 21 G 0,75 15,4 274,0 455,0 19
21415 25 G 0,5 15,7 250,0 406,0 20 21440 25 G 0,75 17,5 306,0 510,0 19
21416 30 G 0,5 16,2 297,0 520,0 20 21443 32 G 0,75 18,9 349,0 688,0 19
21419 36 G 0,5 17,7 320,0 587,0 20 21446 41 G 0,75 21,0 403,0 951,0 19
21420 40 G 0,5 18,4 345,0 655,0 20 21447 50 G 0,75 23,1 470,0 1100,0 19
21421 50 G 0,5 20,7 407,0 742,0 20
Continuation
80
Flexible Control Cables / PUR Control Cables
Y-C-PUR-JZ tear and coolant resistant, Cu-screened, with inner sheath, increased
oil resistant, EMC-preferred type, meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21451 2x1 8,0 54,0 98,0 18 21507 2x4 13,3 124,0 300,0 12
21452 3G1 8,3 64,0 102,0 18 21508 3G4 14,0 178,0 340,0 12
21453 4G1 9,0 76,0 145,0 18 21509 4G4 15,3 234,0 408,0 12
21454 5G1 9,7 89,0 170,0 18 21510 5G4 16,7 284,0 504,0 12
21456 7G1 10,3 114,0 220,0 18 21511 7G4 18,4 321,0 640,0 12
21457 8G1 11,2 130,0 270,0 18 21512 3G6 15,6 245,0 453,0 10
21458 10 G 1 12,6 156,0 330,0 18 21513 4G6 17,0 316,0 560,0 10
21459 12 G 1 13,3 186,0 350,0 18 21514 5G6 18,6 442,0 700,0 10
21460 14 G 1 14,1 198,0 402,0 18 21515 7G6 20,4 530,0 905,0 10
21461 16 G 1 14,8 214,0 420,0 18 21516 3 G 10 19,0 367,0 750,0 8
21462 18 G 1 15,6 284,0 515,0 18 21517 4 G 10 21,1 549,0 1023,0 8
21463 20 G 1 16,4 325,0 545,0 18 21518 5 G 10 23,1 604,0 1114,0 8
21465 25 G 1 18,5 387,0 690,0 18 21519 7 G 10 25,6 820,0 1505,0 8
21468 34 G 1 20,9 500,0 912,0 18 21521 4 G 16 25,3 807,0 1385,0 6
21469 41 G 1 21,5 578,0 1070,0 18 21522 5 G 16 28,0 940,0 1550,0 6
21470 50 G 1 24,8 681,0 1318,0 18 21524 4 G 25 31,1 1169,0 1894,0 4
21474 2 x 1,5 8,6 64,0 130,0 16 21525 5 G 25 34,3 1420,0 2272,0 4
21475 3 G 1,5 9,2 82,0 152,0 16 21526 4 G 35 33,9 1680,0 2395,0 2
21476 4 G 1,5 9,8 99,0 167,0 16 21527 5 G 35 37,8 2020,0 2890,0 2
21477 5 G 1,5 10,8 123,0 203,0 16 21528 4 G 50 40,1 2370,0 3312,0 1
21479 7 G 1,5 11,7 148,0 305,0 16 21529 5 G 50 45,0 2880,0 4100,0 1
21480 8 G 1,5 12,6 172,0 335,0 16 21530 4 G 70 46,0 3257,0 4605,0 2/0
21481 10 G 1,5 14,2 198,0 422,0 16 21531 5 G 70 50,6 4032,0 5710,0 2/0
21482 12 G 1,5 14,9 274,0 435,0 16 21532 4 G 95 51,2 4060,0 6055,0 3/0
21483 14 G 1,5 15,8 294,0 480,0 16 21533 5 G 95 56,5 5244,0 7520,0 3/0
21484 16 G 1,5 16,7 318,0 525,0 16 21534 4 G 120 56,3 5231,0 7318,0 4/0
21485 18 G 1,5 17,4 386,0 642,0 16
21487 21 G 1,5 18,5 447,0 722,0 16
21489 25 G 1,5 20,8 531,0 803,0 16
21492 34 G 1,5 23,2 671,0 1068,0 16
21494 42 G 1,5 25,0 890,0 1370,0 16
21495 50 G 1,5 27,4 997,0 1677,0 16
21499 2 x 2,5 10,1 110,0 180,0 14
21500 3 G 2,5 10,8 148,0 215,0 14
21501 4 G 2,5 11,5 169,0 268,0 14
21502 5 G 2,5 12,8 220,0 349,0 14
21503 7 G 2,5 14,0 284,0 406,0 14
21504 12 G 2,5 17,9 470,0 720,0 14
81
Flexible Control Cables / PUR Control Cables
Application
These robust and flexible cables are used for electrical tools such as drills, hand-held circular saws, and garden equipment as well as for portable
motors and machinery in agriculture, at building sites, for hobbies, docks and refrigeration plants.
Extremely good mechanical characteristies e. g. compressive load, good abrasion and near-resistant.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
1915x 2 x 0,5 6,4 35,0 46,0 20 1925x 2 x 0,75 6,8 40,0 60,0 19
1916x 3 G 0,5 6,8 42,0 56,0 20 1926x 3 G 0,75 7,1 52,0 68,0 19
1917x 4 G 0,5 7,3 47,0 62,0 20 1927x 4 G 0,75 7,7 60,0 78,0 19
1918x 5 G 0,5 7,9 56,0 75,0 20 1928x 5 G 0,75 8,6 71,0 95,0 19
1919x 7 G 0,5 9,4 69,0 98,0 20 1929x 6 G 0,75 9,3 80,0 112,0 19
1920x 12 G 0,5 11,3 108,0 158,0 20 1930x 7 G 0,75 10,3 91,0 138,0 19
1921x 18 G 0,5 13,7 145,0 216,0 20 1931x 12 G 0,75 12,5 142,0 207,0 19
1922x 25 G 0,5 16,3 240,0 315,0 20 1932x 18 G 0,75 14,8 212,0 293,0 19
1923x 34 G 0,5 18,6 312,0 371,0 20 1933x 25 G 0,75 17,9 281,0 413,0 19
1924x 41 G 0,5 20,4 348,0 442,0 20 1934x 34 G 0,75 20,3 345,0 523,0 19
1935x 41 G 0,75 22,1 400,0 609,0 19
Continuation
82
Flexible Control Cables / PUR Control Cables
83
Flexible Control Cables / PUR Control Cables
Application
PUR-C-PUR screened cables are well suited as data transfer and connection cables for the machine and motor industries due to the good level of
copper screening which blocks strong electrical disturbances.
This cable type has proven to be especially suited to use in extreme weather and environmental conditions due to its good thermal and chemical
properties (Temperature range -40C to +80C). In addition to this it also possesses excellent mechanical properties, e. g. pressure resistance and
good abrasive resistant qualities, all of which go to guarantee a long life.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22315 2 x 0,75 6,8 40,0 65,0 19 22364 2 x 1,5 8,6 63,0 101,0 16
22316 3 G 0,75 7,2 52,0 80,0 19 22365 3 G 1,5 9,3 80,0 125,0 16
22317 4 G 0,75 8,0 60,0 95,0 19 22366 4 G 1,5 10,1 97,0 150,0 16
22318 5 G 0,75 8,6 71,0 126,0 19 22367 5 G 1,5 11,2 119,0 210,0 16
22319 6 G 0,75 9,5 80,0 150,0 19 22385 2 x 2,5 10,4 96,0 142,0 14
22339 2x1 7,2 50,0 80,0 18 22386 3 G 2,5 11,0 144,0 169,0 14
22340 3G1 7,8 60,0 95,0 18 22387 4 G 2,5 12,2 148,0 225,0 14
22341 4G1 8,4 71,0 106,0 18 22388 5 G 2,5 13,6 181,0 275,0 14
22342 5G1 9,5 88,0 149,0 18
84
HALOGEN-FREE CONTROL CABLES
Flexible Control Cables / Halogen-free Control Cables
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification when
ordering.
screened analogue type:
JZ-500 HMH-C, confer page 96
Application
Used as measuring, monitoring and control cables in tool machinery, conveyor belts, production lines, in plant, in air-conditioning, in foundries and
steel mills. For fixed installation or flexible application, casual, not constantly recurring free movement without forced motion and without tensile
stress, for medium mechanical stress. The cable is suitable for use in dry, damp and wet locations and on plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11201 2 x 0,5 4,8 9,6 43,0 20 11210 18 G 0,5 10,7 86,0 204,0 20
11202 3 G 0,5 5,1 14,4 50,0 20 11211 20 G 0,5 11,3 96,0 227,0 20
11332 3 x 0,5 5,1 14,4 50,0 20 11212 25 G 0,5 12,6 120,0 283,0 20
11203 4 G 0,5 5,6 19,0 60,0 20 11213 30 G 0,5 13,5 144,0 324,0 20
11333 4 x 0,5 5,5 19,0 60,0 20 11214 34 G 0,5 14,3 163,0 367,0 20
11204 5 G 0,5 6,2 24,0 71,0 20 11215 37 G 0,5 14,5 178,0 381,0 20
11334 5 x 0,5 6,2 24,0 71,0 20 11216 41 G 0,5 15,8 197,0 417,0 20
11205 7 G 0,5 6,7 33,6 84,0 20 11217 42 G 0,5 15,8 202,0 454,0 20
11206 8 G 0,5 7,4 38,0 101,0 20 11218 50 G 0,5 17,5 240,0 519,0 20
11207 10 G 0,5 8,3 48,0 121,0 20 11219 61 G 0,5 18,5 293,0 635,0 20
11208 12 G 0,5 8,7 58,0 142,0 20 11220 65 G 0,5 19,4 312,0 694,0 20
11209 16 G 0,5 10,0 76,0 183,0 20
Continuation
86
Flexible Control Cables / Halogen-free Control Cables
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11221 2 x 0,75 5,3 14,4 47,0 19 11277 2 x 2,5 7,8 48,0 118,0 14
11222 3 G 0,75 5,6 21,6 56,0 19 11278 3 G 2,5 8,3 72,0 151,0 14
11335 3 x 0,75 5,6 21,6 56,0 19 11279 4 G 2,5 9,2 96,0 181,0 14
11223 4 G 0,75 6,3 29,0 69,0 19 11280 5 G 2,5 10,1 120,0 224,0 14
11336 4 x 0,75 6,3 29,0 69,0 19 11281 7 G 2,5 11,2 168,0 316,0 14
11224 5 G 0,75 6,9 36,0 83,0 19 11282 8 G 2,5 12,3 192,0 370,0 14
11337 5 x 0,75 6,9 36,0 83,0 19 11283 10 G 2,5 14,0 240,0 451,0 14
11225 7 G 0,75 7,5 50,0 114,0 19 11284 12 G 2,5 14,8 288,0 499,0 14
11338 7 x 0,75 7,5 50,0 114,0 19 11285 16 G 2,5 17,1 384,0 720,0 14
11226 8 G 0,75 8,3 58,0 136,0 19 11286 18 G 2,5 18,2 432,0 769,0 14
11227 10 G 0,75 9,2 72,0 172,0 19 11287 20 G 2,5 19,2 480,0 911,0 14
11228 12 G 0,75 9,8 86,0 183,0 19 11288 25 G 2,5 21,6 600,0 1047,0 14
11229 16 G 0,75 11,4 115,0 241,0 19 11289 30 G 2,5 23,0 720,0 1280,0 14
11230 18 G 0,75 12,2 130,0 266,0 19 11290 2x4 9,3 77,0 199,0 12
11231 20 G 0,75 12,7 144,0 291,0 19 11291 3G4 9,8 115,0 247,0 12
11232 25 G 0,75 14,3 180,0 374,0 19 11292 4G4 10,9 154,0 299,0 12
11233 30 G 0,75 15,3 216,0 450,0 19 11293 5G4 12,1 192,0 369,0 12
11234 34 G 0,75 16,5 245,0 517,0 19 11294 7G4 13,2 269,0 463,0 12
11235 37 G 0,75 16,7 260,0 541,0 19 11295 8G4 14,7 307,0 601,0 12
11236 41 G 0,75 18,1 296,0 611,0 19 11296 10 G 4 17,5 384,0 698,0 12
11237 42 G 0,75 18,1 302,0 621,0 19 11297 12 G 4 17,7 461,0 790,0 12
11238 50 G 0,75 19,8 360,0 742,0 19 11298 16 G 4 20,3 614,0 1130,0 12
11239 61 G 0,75 21,2 439,0 853,0 19 11299 18 G 4 21,6 691,0 1280,0 12
11240 65 G 0,75 21,8 468,0 909,0 19 11300 2x6 11,0 115,0 266,0 10
11241 2x1 5,6 19,2 63,0 18 11301 3G6 11,9 173,0 360,0 10
11242 3G1 5,9 29,0 74,0 18 11302 4G6 13,0 230,0 429,0 10
11339 3x1 5,9 29,0 74,0 18 11303 5G6 14,5 288,0 529,0 10
11243 4G1 6,6 38,4 90,0 18 11304 7G6 16,2 403,0 631,0 10
11340 4x1 6,6 38,4 90,0 18 11305 2 x 10 13,8 192,0 440,0 8
11244 5G1 7,3 48,0 109,0 18 11306 3 G 10 14,9 288,0 550,0 8
11245 7G1 8,1 67,0 151,0 18 11307 4 G 10 16,5 384,0 708,0 8
11246 8G1 8,8 77,0 184,0 18 11308 5 G 10 18,3 480,0 862,0 8
11247 10 G 1 9,8 96,0 224,0 18 11309 7 G 10 20,2 672,0 1124,0 8
11248 12 G 1 10,4 115,0 243,0 18 11310 2 x 16 16,8 307,0 642,0 6
11249 16 G 1 12,3 154,0 314,0 18 11311 3 G 16 18,3 461,0 830,0 6
11250 18 G 1 12,9 173,0 361,0 18 11312 4 G 16 20,1 614,0 1060,0 6
11251 20 G 1 13,8 192,0 387,0 18 11313 5 G 16 22,6 768,0 1270,0 6
11252 25 G 1 15,4 240,0 496,0 18 11314 7 G 16 24,8 1075,0 1794,0 6
11253 34 G 1 17,7 326,0 670,0 18 11315 3 G 25 22,3 720,0 1190,0 4
11254 37 G 1 17,9 355,0 713,0 18 11316 4 G 25 25,0 960,0 1594,0 4
11255 41 G 1 19,5 394,0 784,0 18 11317 5 G 25 27,7 1200,0 2014,0 4
11256 42 G 1 19,5 403,0 824,0 18 11318 3 G 35 25,9 1008,0 1590,0 2
11257 50 G 1 21,3 480,0 952,0 18 11319 4 G 35 28,7 1344,0 2200,0 2
11258 61 G 1 22,5 586,0 1140,0 18 11320 5 G 35 31,9 1680,0 2693,0 2
11259 65 G 1 23,6 628,0 1201,0 18 11321 3 G 50 30,8 1440,0 2571,0 1
11260 2 x 1,5 6,4 29,0 70,0 16 11322 4 G 50 34,1 1920,0 3087,0 1
11261 3 G 1,5 6,8 43,0 94,0 16 11323 5 G 50 38,1 2400,0 3980,0 1
11341 3 x 1,5 6,8 43,0 94,0 16 11324 3 G 70 36,4 2016,0 3207,0 2/0
11262 4 G 1,5 7,4 58,0 112,0 16 11325 4 G 70 40,2 2688,0 4077,0 2/0
11263 5 G 1,5 8,3 72,0 141,0 16 11326 5 G 70 44,7 3360,0 5501,0 2/0
11264 7 G 1,5 9,2 101,0 191,0 16 11327 3 G 95 41,3 2736,0 4708,0 3/0
11265 8 G 1,5 10,0 115,0 224,0 16 11328 4 G 95 46,0 3648,0 5590,0 3/0
11266 10 G 1,5 10,9 144,0 282,0 16 11329 5 G 95 50,7 4560,0 6972,0 3/0
11267 12 G 1,5 11,8 173,0 311,0 16 11330 3 G 120 47,0 3456,0 5515,0 4/0
11268 16 G 1,5 13,9 230,0 392,0 16 11331 4 G 120 51,0 4608,0 7100,0 4/0
11269 18 G 1,5 14,6 259,0 450,0 16
11270 20 G 1,5 15,6 288,0 497,0 16
11271 25 G 1,5 17,4 360,0 630,0 16
11272 34 G 1,5 20,2 490,0 842,0 16
11273 37 G 1,5 20,2 533,0 897,0 16
11274 50 G 1,5 24,2 720,0 1277,0 16
11275 61 G 1,5 25,8 878,0 1460,0 16
11276 65 G 1,5 26,8 936,0 1612,0 16
87
Flexible Control Cables / Halogen-free Control Cables UL/CSA
Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress, for high
mechanical strain. As a measuring and control cable primarily in machinery and plant construction, in air-conditoning systems, at the warehouse and
conveyor systems, in ship-building and in the renewable energies such as in the construction of wind power stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13344 2 x 0,5 20 5,0 9,6 43,0 13353 10 G 0,5 20 8,8 48,0 121,0
13345 3 G 0,5 20 5,3 14,4 50,0 13354 12 G 0,5 20 9,1 58,0 142,0
13346 3 x 0,5 20 5,3 14,4 50,0 13355 16 G 0,5 20 10,0 76,0 183,0
13347 4 G 0,5 20 5,7 19,0 60,0 13356 18 G 0,5 20 10,7 86,0 204,0
13348 4 x 0,5 20 5,7 19,0 60,0 13357 20 G 0,5 20 11,2 96,0 227,0
13349 5 G 0,5 20 6,2 24,0 71,0 13359 25 G 0,5 20 12,7 120,0 283,0
13350 5 x 0,5 20 6,2 24,0 71,0 13360 30 G 0,5 20 13,5 144,0 324,0
13351 7 G 0,5 20 7,4 33,6 84,0 13361 34 G 0,5 20 14,5 163,0 367,0
13352 8 G 0,5 20 8,0 38,0 101,0 13362 37 G 0,5 20 14,5 178,0 381,0
Continuation
88
Flexible Control Cables / Halogen-free Control Cables UL/CSA
89
Halogen-free hose cable
Application
Single and multicore sheathed cable, with low smoke and corrosive gas production in case of fire for interior use. Not suitable for continuous outside
use. In this case, cable with a special tested covering should be used. Skin contact should be avoided when the cable is used in high temperatures.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm approx. mm kg / km kg / km mm approx. mm kg / km kg / km
37176 1 x 1,5 5,7 - 7,1 14,4 58,0 16 37218 3 G 300 72,0 - 90,0 8640,0 12620,0 600 kcmil
37177 1 x 2,5 6,3 - 7,9 24,0 71,0 14 37219 4G1 9,2 - 11,9 38,0 141,0 18
37178 1x4 7,2 - 9,0 38,0 100,0 12 37220 4 G 1,5 10,2 - 13,1 58,0 176,0 16
37179 1x6 7,9 - 9,8 58,0 130,0 10 37221 4 G 2,5 12,1 - 15,5 96,0 235,0 14
37180 1 x 10 9,5 - 11,9 96,0 230,0 8 37222 4G4 14,0 - 17,9 154,0 365,0 12
37181 1 x 16 10,8 - 13,4 154,0 290,0 6 37223 4G6 15,7 - 20,0 230,0 501,0 10
37182 1 x 25 12,7 - 15,8 240,0 420,0 4 37224 4 G 10 20,9 - 26,5 384,0 872,0 8
37183 1 x 35 14,3 - 17,9 336,0 530,0 2 37225 4 G 16 23,8 - 30,1 614,0 1194,0 6
37184 1 x 50 16,5 - 20,6 480,0 750,0 1 37226 4 G 25 28,9 - 36,6 960,0 1822,0 4
37185 1 x 70 18,6 - 23,3 672,0 960,0 2/0 37227 4 G 35 32,5 - 41,1 1344,0 2307,0 2
37186 1 x 95 20,8 - 26,0 912,0 1250,0 3/0 37228 4 G 50 37,7 - 47,5 1920,0 3253,0 1
37187 1 x 120 22,8 - 28,6 1152,0 1560,0 4/0 37229 4 G 70 42,7 - 54,0 2688,0 4130,0 2/0
37188 1 x 150 25,2 - 31,4 1440,0 1900,0 300 kcmil 37230 4 G 95 48,4 - 61,0 3648,0 5720,0 3/0
37189 1 x 185 27,6 - 34,4 1776,0 2300,0 350 kcmil 37231 4 G 120 53,0 - 66,0 4608,0 6965,0 4/0
37190 1 x 240 30,6 - 38,3 2304,0 2950,0 500 kcmil 37232 4 G 150 58,0 - 73,0 5760,0 8644,0 300 kcmil
37191 1 x 300 33,5 - 41,9 2880,0 3600,0 600 kcmil 37233 4 G 185 64,0 - 80,0 7104,0 10598,0 350 kcmil
37192 1 x 400 37,4 - 46,8 3840,0 4600,0 750 kcmil 37234 4 G 240 72,0 - 91,0 9216,0 12100,0 500 kcmil
37193 1 x 500 41,3 - 52,0 4800,0 6000,0 1000 kcmil 37235 4 G 300 80,0 - 101,0 11520,0 15200,0 600 kcmil
37194 2x1 7,7 - 10,0 19,0 95,0 18 37236 5G1 10,2 - 13,1 48,0 170,0 18
37195 2 x 1,5 8,5 - 11,0 29,0 119,0 16 37237 5 G 1,5 11,2 - 14,4 72,0 214,0 16
37196 2 x 2,5 10,2 - 13,1 48,0 172,0 14 37238 5 G 2,5 13,3 - 17,0 120,0 316,0 14
37197 2x4 11,8 - 15,1 77,0 239,0 12 37239 5G4 15,6 - 19,9 192,0 448,0 12
37198 2x6 13,1 - 16,8 115,0 319,0 10 37240 5G6 17,5 - 22,2 288,0 607,0 10
37199 2 x 10 17,7 - 22,6 192,0 572,0 8 37241 5 G 10 22,9 - 29,1 480,0 1075,0 8
37200 2 x 16 20,2 - 25,7 307,0 767,0 6 37242 5 G 16 26,4 - 33,3 768,0 1480,0 6
37201 2 x 25 24,3 - 30,7 480,0 1154,0 4 37243 5 G 25 32,0 - 40,4 1200,0 2255,0 4
37202 3G1 8,3 - 10,7 29,0 115,0 18 37244 6 G 1,5 13,4 - 17,2 84,0 287,0 16
37203 3 G 1,5 9,2 - 11,9 43,0 144,0 16 37245 6 G 2,5 15,7 - 20,0 144,0 420,0 14
37204 3 G 2,5 10,9 - 14,0 72,0 211,0 14 37246 6G4 18,2 - 23,2 230,0 583,0 12
37205 3G4 12,7 - 16,2 115,0 290,0 12 37247 7 G 1,5 11,4 - 14,4 101,0 303,0 16
37206 3G6 14,1 - 18,0 173,0 391,0 10 37248 7 G 2,5 13,4 - 17,0 168,0 448,0 14
37207 3 G 10 19,1 - 24,2 288,0 706,0 8 37249 12 G 1,5 17,6 - 22,4 173,0 496,0 16
37208 3 G 16 21,8 - 27,6 461,0 961,0 6 37250 12 G 2,5 20,6 - 26,2 288,0 724,0 14
37209 3 G 25 26,1 - 33,0 720,0 1438,0 4 37251 12 G 4 24,4 - 30,9 461,0 1042,0 12
37210 3 G 35 29,3 - 37,1 1008,0 1814,0 2 37252 18 G 1,5 20,7 - 26,3 259,0 702,0 16
37211 3 G 50 34,1 - 42,9 1440,0 2550,0 1 37253 18 G 2,5 24,4 - 30,9 432,0 1045,0 14
37212 3 G 70 38,4 - 48,3 2016,0 3210,0 2/0 37254 18 G 4 28,8 - 36,4 691,0 1430,0 12
37213 3 G 95 43,3 - 54,0 2736,0 4423,0 3/0 37255 24 G 1,5 24,3 - 30,7 346,0 935,0 16
37214 3 G 120 47,4 - 60,0 3456,0 5405,0 4/0 37256 24 G 2,5 28,8 - 36,4 576,0 1325,0 14
37215 3 G 150 52,0 - 66,0 4320,0 6725,0 300 kcmil 37257 36 G 1,5 27,8 - 35,2 518,0 1297,0 16
37216 3 G 185 57,0 - 72,0 5328,0 8222,0 350 kcmil 37258 36 G 2,5 33,2 - 41,8 864,0 1949,0 14
37217 3 G 240 65,0 - 82,0 6192,0 10224,0 500 kcmil
90
Flexible Control Cables / Halogen-free Control Cables
JZ-600 HMH flexible control cable, halogen-free, extremely fire resistant, oil
resistant , 0,6/1kV, meter marking
1)
adapted to DIN VDE 0285-525-2-51/ DIN VDE 0295 cl.5, fine-wire, that you consult
DIN EN 50525-2-51 and BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
DIN VDE 0285-525-3-11/ Core insulation of halogen-free polymer cadmium-free and contain no silicone
DIN EN 50525-3-11 compound type TI6 to and free from substances harmful to
Temperature range DIN VDE 0207-363-7 / DIN EN 50363-7 the wetting properties of lacquers
flexing -15C to +70C Core identification to DIN VDE 0293 Tests
fixed -40C to +70C black cores with continuous white Flame test acc. to
Nominal voltage U0/U 0,6/1 kV numbering DIN VDE 0482-332-3, BS 4066 part 3,
Test voltage 4000 V GN-YE conductor, 3 cores and above DIN EN 60332-3, IEC 60332-3 (previously
Minimum bending radius in the outer layer DIN VDE 0472 part 804 test method C)
flexing 15x cable Cores stranded in layers with self-extinguishing and flame retardant
fixed installation 7,5x cable optimal lay-length acc. to DIN VDE 0482-332-1-2,
Radiation resistance Outer sheath of halogen-free polymer DIN EN 60332-1-2/IEC 60332-1 (equivalent
up to 100x106 cJ/kg (up to 100 Mrad) compound type TM7 to DIN VDE 0472 part 804 test method B)
DIN VDE 0207-363-8 / DIN EN 50363-8 Corrosiveness of combustion gases
Sheath colour black (RAL 9005) acc. to DIN VDE 0482 part 267,
with meter marking DIN EN 50267-2-2, IEC 60754-2
LS0H= Low Smoke Zero Halogen (equivalent DIN VDE 0472 part 813)
Halogen-free acc. to DIN VDE 0482 Part 267/
DIN EN 50267-2-1 / IEC 60754-1 (as per
DIN VDE 0472, Part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
JZ-600 HMH-C, confer page 100
Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as in plant
installations, in heating and air-conditioning systems and steel production works. For fixed installation or flexible application, directed without forcing
by casual, constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the application in
dry, damp and wet environments, outdoors (fixed installation) and for laying on plaster.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12723 2 x 0,5 6,3 9,6 57,0 20 12735 2 x 0,75 6,6 14,4 68,0 19
12724 3 G 0,5 6,6 14,4 69,0 20 12736 3 G 0,75 6,9 21,6 77,0 19
12725 3 x 0,5 6,6 14,4 69,0 20 12737 3 x 0,75 6,9 21,6 77,0 19
12726 4 G 0,5 7,2 19,0 104,0 20 12738 4 G 0,75 7,5 29,0 136,0 19
12727 4 x 0,5 7,2 19,0 104,0 20 12739 4 x 0,75 7,5 29,0 136,0 19
12728 5 G 0,5 8,0 24,0 121,0 20 12740 5 G 0,75 8,4 36,0 152,0 19
12729 5 x 0,5 8,0 24,0 121,0 20 12741 5 x 0,75 8,4 36,0 152,0 19
12730 7 G 0,5 8,7 33,6 145,0 20 12742 7 G 0,75 9,3 50,0 208,0 19
12731 10 G 0,5 10,3 48,0 186,0 20 12743 10 G 0,75 11,4 72,0 250,0 19
12732 12 G 0,5 11,2 58,0 224,0 20 12744 12 G 0,75 12,2 86,0 271,0 19
12733 18 G 0,5 13,8 86,0 292,0 20 12745 18 G 0,75 14,5 130,0 387,0 19
12734 25 G 0,5 16,1 120,0 357,0 20 12746 25 G 0,75 17,2 180,0 498,0 19
Continuation
91
Flexible Control Cables / Halogen-free Control Cables
JZ-600 HMH flexible control cable, halogen-free, extremely fire resistant, oil
resistant , 0,6/1kV, meter marking
1)
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12747 2x1 7,0 19,2 82,0 18 12783 3G4 11,7 115,0 255,0 12
12748 3G1 7,4 29,0 99,0 18 12784 4G4 12,9 154,0 319,0 12
12749 3x1 7,4 29,0 99,0 18 12785 5G4 14,4 192,0 423,0 12
12750 4G1 8,2 38,4 140,0 18 12786 3G6 13,1 173,0 380,0 10
12751 4x1 8,2 38,4 140,0 18 12787 4G6 14,5 230,0 441,0 10
12752 5G1 9,2 48,0 160,0 18 12788 5G6 16,2 288,0 657,0 10
12753 5x1 9,2 48,0 160,0 18 12789 3 G 10 16,8 288,0 668,0 8
12754 7G1 9,9 67,0 217,0 18 12790 4 G 10 18,5 384,0 796,0 8
12755 10 G 1 11,9 96,0 271,0 18 12791 5 G 10 20,5 480,0 972,0 8
12756 12 G 1 12,8 115,0 301,0 18 12792 3 G 16 20,2 461,0 832,0 6
12757 18 G 1 15,7 173,0 417,0 18 12793 4 G 16 22,4 614,0 1122,0 6
12758 25 G 1 18,6 240,0 576,0 18 12794 5 G 16 25,0 768,0 1604,0 6
12759 2 x 1,5 8,2 29,0 97,0 16 12795 3 G 25 24,8 720,0 1457,0 4
12760 3 G 1,5 8,6 43,0 119,0 16 12796 4 G 25 27,4 960,0 1611,0 4
12761 3 x 1,5 8,6 43,0 119,0 16 12797 5 G 25 30,5 1200,0 2070,0 4
12762 4 G 1,5 9,6 58,0 148,0 16 12798 3 G 35 27,4 1008,0 1914,0 2
12763 4 x 1,5 9,6 58,0 148,0 16 12799 4 G 35 30,3 1344,0 2424,0 2
12764 5 G 1,5 10,7 72,0 172,0 16 12800 5 G 35 33,6 1680,0 2970,0 2
12765 5 x 1,5 10,7 72,0 172,0 16 12801 4 G 50 35,8 1920,0 3467,0 1
12766 7 G 1,5 11,6 101,0 243,0 16 12802 4 G 70 40,8 2688,0 4491,0 2/0
12767 10 G 1,5 15,2 144,0 311,0 16 12803 4 G 95 46,2 3648,0 6170,0 3/0
12768 12 G 1,5 15,5 173,0 392,0 16 12804 4 G 120 51,6 4608,0 7618,0 4/0
12769 18 G 1,5 18,6 259,0 529,0 16
12770 25 G 1,5 22,5 360,0 741,0 16
12771 2 x 2,5 9,6 48,0 160,0 14
12772 3 G 2,5 10,1 72,0 177,0 14
12773 3 x 2,5 10,1 72,0 177,0 14
12774 4 G 2,5 11,2 96,0 209,0 14
12775 4 x 2,5 11,2 96,0 209,0 14
12776 5 G 2,5 12,5 120,0 272,0 14
12777 5 x 2,5 12,5 120,0 272,0 14
12778 7 G 2,5 13,8 168,0 340,0 14
12779 10 G 2,5 16,6 288,0 561,0 14
12780 12 G 2,5 18,3 432,0 799,0 14
12781 18 G 2,5 22,0 480,0 940,0 14
12782 25 G 2,5 26,2 600,0 1121,0 14
92
Flexible Control Cables / Halogen-free Control Cables
JB-750 HMH flexible control cable, coloured core, halogen-free, extremely fire
resistant, oil resistant , meter marking
1)
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
Please note the cleanroom qualification
when ordering.
AWG sizes are approximate equivalent
values.
The actual cross-section is in mm.
screened analogue type:
JB-750 HMH-C, confer page 102
Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as in plant
installations, in air-conditioning and steel production works. For fixed installation or flexible application, directed without forcing by casual, not
constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the application in dry, damp
and wet environments and also for laying on plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11965 3 G 1,5 7,8 43,0 110,0 16 11976 4 G 10 18,1 384,0 750,0 8
11966 4 G 1,5 8,5 58,0 140,0 16 11977 5 G 10 20,1 480,0 916,0 8
11967 5 G 1,5 9,6 72,0 181,0 16 11978 4 G 16 22,0 614,0 1037,0 6
11968 3 G 2,5 9,3 72,0 181,0 14 11979 5 G 16 24,4 768,0 1280,0 6
11969 4 G 2,5 10,2 96,0 223,0 14 11980 4 G 25 27,1 960,0 1504,0 4
11970 5 G 2,5 11,4 120,0 269,0 14 11981 5 G 25 30,1 1200,0 1883,0 4
11971 3G4 11,3 115,0 238,0 12 11982 4 G 35 29,9 1344,0 2057,0 2
11972 4G4 12,5 154,0 292,0 12 11983 5 G 35 33,4 1680,0 2575,0 2
11973 5G4 13,9 192,0 357,0 12 11984 4 G 50 35,5 1920,0 2808,0 1
11974 4G6 14,2 230,0 392,0 10 11985 4 G 70 40,2 2688,0 3964,0 2/0
11975 5G6 15,8 288,0 501,0 10 11986 4 G 95 46,0 3648,0 4951,0 3/0
11987 4 G 120 51,3 4608,0 6387,0 4/0
93
Flexible Control Cables / Halogen-free Control Cables
Note
G = with green-yellow conductor
x = without green-yellow conductor
Please complete the part number for
these cables by adding the suffix for
the colour required as per the list:
0 = ca.RAL 9005 black
1 = ca.RAL 9003 withe
2 = ca.RAL 5015 blue
3 = ca.RAL 6018 green
4 = ca.RAL 8003 brown
5 = ca.RAL 1021 yellow
6 = ca.RAL 3000 red
7 = ca.RAL 2003 orange
8 = ca.RAL 4005 violet
9 = ca.RAL 7001/7032 grey
Further colours on request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
These cables may be used when halogen-free, low smoke and corrosive gas properties are required in case of fire. For low mechanical demands in
the house, kitchen and office, for small equipment such as, for example, office machines, radios, table and stranded lamps.
Not suitable for:
Cooking and heating equipment, use in high temperature areas (for example, in lighting equipment), outside use, industrial use or idustrial electrical
tools, cables with a nominal cross-section of 0,75 mm comply with the same recommendations as for cable (H)05Z1Z1-F.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
3233x 2 x 0,5 5,1 9,6 39,0 20 3236x 2 x 0,75 5,4 14,4 47,0 19
3234x 3 G 0,5 5,4 14,4 46,0 20 3237x 3 G 0,75 5,7 21,6 55,0 19
3235x 4 G 0,5 5,9 19,2 56,0 20 3238x 4 G 0,75 6,3 29,0 69,0 19
94
Flexible Control Cables / Halogen-free Control Cables
Note
G = with green-yellow conductor
x = without green-yellow conductor
Please complete the part number for
these cables by adding the suffix for
the colour required as per the list:
0 = ca.RAL 9005 black
1 = ca.RAL 9003 withe
2 = ca.RAL 5015 blue
3 = ca.RAL 6018 green
4 = ca.RAL 8003 brown
5 = ca.RAL 1021 yellow
6 = ca.RAL 3000 red
7 = ca.RAL 2003 orange
8 = ca.RAL 4005 violet
9 = ca.RAL 7001/7032 grey
Further colours on request.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
These cables may be used when halogen-free, low smoke and corrosive gas properties are required in case of fire. For moderate mechanical demands
in the house, kitchen and office, for house equipment in damp rooms (for example: washing machines, spin-dryers and refrigerators).
Suitable for cooking and heating equipment, providing the cable is not in contact with hot components or heat radiation.
Not suitable for:
in high temperature areas (for example, in lighting equipment), outside buildings, in industrial or agricultural buildings, connection of electrical power
tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
3027x 2 x 0,75 6,3 14,4 58,0 19 3043x 5 G 2,5 12,0 120,0 260,0 14
3028x 3 G 0,75 6,6 21,6 68,0 19 3044x 2x4 10,4 76,8 190,0 12
3029x 4 G 0,75 7,2 29,0 81,0 19 3045x 3G4 11,3 115,2 242,0 12
3030x 5 G 0,75 8,0 36,0 102,0 19 3046x 4G4 12,3 153,6 298,0 12
3031x 2x1 6,5 19,0 67,0 18 3047x 5G4 13,9 192,0 371,0 12
3032x 3G1 6,9 29,0 81,0 18
3034x 4G1 7,7 38,0 101,0 18
3035x 5G1 8,4 48,0 107,0 18
3036x 2 x 1,5 7,4 29,0 87,0 16
3037x 3 G 1,5 8,0 43,0 109,0 16
3038x 4 G 1,5 9,1 58,0 117,0 16
3039x 5 G 1,5 10,0 72,0 169,0 16
3040x 2 x 2,5 9,1 48,0 138,0 14
3041x 3 G 2,5 9,9 72,0 172,0 14
3042x 4 G 2,5 10,8 96,0 210,0 14
95
Flexible Control Cables / Halogen-free Control Cables
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified" when
ordering.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-500 HMH, confer page 86
Application
Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts,
production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for
casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable
for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of
screening.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11656 2 x 0,5 5,7 35,0 46,0 20 11678 2 x 0,75 6,1 40,0 60,0 19
11657 3 G 0,5 5,9 42,0 56,0 20 11679 3 G 0,75 6,3 52,0 68,0 19
11342 3 x 0,5 5,9 42,0 56,0 20 11344 3 x 0,75 6,3 52,0 68,0 19
11658 4 G 0,5 6,4 47,0 62,0 20 11680 4 G 0,75 6,8 60,0 78,0 19
11343 4 x 0,5 6,4 47,0 62,0 20 11345 4 x 0,75 6,8 60,0 78,0 19
11659 5 G 0,5 6,9 56,0 75,0 20 11681 5 G 0,75 7,4 71,0 95,0 19
11660 7 G 0,5 7,6 69,0 98,0 20 11346 5 x 0,75 7,4 71,0 95,0 19
11663 12 G 0,5 9,7 108,0 158,0 20 11682 7 G 0,75 8,2 91,0 130,0 19
11665 18 G 0,5 11,5 145,0 216,0 20 11347 7 x 0,75 8,2 91,0 130,0 19
11667 25 G 0,5 13,7 240,0 315,0 20 11685 12 G 0,75 10,5 142,0 203,0 19
Continuation
96
Flexible Control Cables / Halogen-free Control Cables
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11687 18 G 0,75 12,7 212,0 290,0 19 11781 2G6 11,7 173,0 270,0 10
11689 25 G 0,75 15,0 281,0 413,0 19 11782 3G6 12,5 240,0 328,0 10
11700 2x1 6,4 50,0 66,0 18 11783 4G6 13,8 305,0 416,0 10
11701 3G1 6,7 60,0 80,0 18 11784 5G6 15,4 439,0 510,0 10
11348 3x1 6,7 60,0 80,0 18 11785 7G6 17,0 505,0 670,0 10
11702 4G1 7,2 71,0 100,0 18 11786 2 x 10 14,5 255,0 420,0 8
11349 4x1 7,2 71,0 100,0 18 11787 3 G 10 15,6 350,0 495,0 8
11703 5G1 8,0 88,0 130,0 18 11788 4 G 10 17,2 535,0 785,0 8
11704 7G1 8,7 111,0 160,0 18 11789 5 G 10 19,1 592,0 855,0 8
11707 12 G 1 11,4 184,0 260,0 18 11790 7 G 10 21,2 810,0 1308,0 8
11709 18 G 1 13,6 260,0 382,0 18 11793 4 G 16 20,3 740,0 882,0 6
11711 25 G 1 16,2 349,0 540,0 18 11794 5 G 16 22,2 895,0 1293,0 6
11722 2 x 1,5 7,0 63,0 88,0 16 11812 7 G 16 24,8 1282,0 2149,0 6
11723 3 G 1,5 7,4 80,0 100,0 16 11795 3 G 25 22,5 1070,0 1432,0 4
11350 3 x 1,5 7,4 80,0 100,0 16 11796 4 G 25 25,0 1140,0 1911,0 4
11724 4 G 1,5 8,1 97,0 125,0 16 11797 5 G 25 27,5 1380,0 2414,0 4
11725 5 G 1,5 9,0 119,0 158,0 16 11798 3 G 35 25,7 1240,0 1914,0 2
11726 7 G 1,5 9,8 147,0 210,0 16 11799 4 G 35 28,5 1576,0 2542,0 2
11729 12 G 1,5 12,8 267,0 340,0 16 11800 5 G 35 31,7 1930,0 3180,0 2
11731 18 G 1,5 15,6 374,0 480,0 16 11801 3 G 50 30,8 1675,0 3080,0 1
11733 25 G 1,5 18,4 526,0 702,0 16 11802 4 G 50 34,1 2155,0 3550,0 1
11744 2 x 2,5 8,4 96,0 132,0 14 11803 5 G 50 38,1 2794,0 4753,0 1
11745 3 G 2,5 8,8 144,0 168,0 14 11804 3 G 70 36,0 2288,0 3840,0 2/0
11746 4 G 2,5 9,8 148,0 195,0 14 11805 4 G 70 40,0 3120,0 4939,0 2/0
11747 5 G 2,5 10,8 181,0 222,0 14 11806 5 G 70 44,5 3705,0 6572,0 2/0
11748 7 G 2,5 11,9 255,0 345,0 14 11807 3 G 95 41,1 3010,0 5651,0 3/0
11751 12 G 2,5 15,8 441,0 572,0 14 11808 4 G 95 45,6 4043,0 6690,0 3/0
11766 2x4 10,0 120,0 184,0 12 11809 5 G 95 50,7 5026,0 8370,0 3/0
11768 3G4 10,6 174,0 238,0 12 11810 3 G 120 45,2 3812,0 6342,0 4/0
11769 4G4 11,6 230,0 305,0 12 11811 4 G 120 50,1 5069,0 8453,0 4/0
11770 5G4 12,8 273,0 388,0 12 11813 4 G 185 63,0 8040,0 10800,0 350 kcmil
11771 7G4 14,2 316,0 504,0 12
97
Flexible Control Cables / Halogen-free Control Cables UL/CSA
Application
For fixed installation or flexible application that does not permanently recurring free movement without forced motion and without tensile stress, for
high mechanical strain. As a measuring and control cable e. g. in machine and plant engineering, air conditioning in the warehouse and materials
handling, shipbuilding and in the newable energies such as wind power stations.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
13500 2 x 0,5 20 5,7 35,0 46,0 13508 8 G 0,5 20 8,5 80,0 116,0
13501 3 G 0,5 20 6,0 42,0 56,0 13509 10 G 0,5 20 9,3 94,0 135,0
13502 3 x 0,5 20 6,0 42,0 56,0 13510 12 G 0,5 20 9,6 108,0 158,0
13504 4 x 0,5 20 6,5 47,0 62,0 13511 16 G 0,5 20 10,7 129,0 210,0
13503 4 G 0,5 20 6,5 47,0 62,0 13512 18 G 0,5 20 11,2 145,0 216,0
13505 5 G 0,5 20 7,0 56,0 75,0 13514 20 G 0,5 20 11,9 172,0 240,0
13506 5 x 0,5 20 7,0 56,0 75,0 13515 25 G 0,5 20 13,4 240,0 315,0
13507 7 G 0,5 20 7,9 69,0 98,0
Continuation
98
Flexible Control Cables / Halogen-free Control Cables UL/CSA
99
Flexible Control Cables / Halogen-free Control Cables
JZ-600 HMH-C flexible control cable, halogen-free, extremely fire resistant, oil
resistant , 0,6/1kV, screened, EMC-preferred type, meter marking
1)
core construction adapted to DIN VDE 0295 cl.5, fine-wire, request a consultation
DIN VDE 0285-525-2-51/ BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
DIN EN 50525-2-51 Core insulation of halogen-free polymer cadmium-free and contain no silicone
and DIN VDE 0285-525-3-11/ compound type TI6 to and free from substances harmful to
DIN EN 50525-3-11 DIN VDE 0207-363-7 / DIN EN 50363-7 the wetting properties of lacquers
Temperature range Core identification to DIN VDE 0293 Tests
flexing -15C to +70C black cores with continuous white Flame test acc. to
fixed -40C to +70C numbering DIN VDE 0482-332-3, BS 4066 part 3,
Nominal voltage U0/U 0,6/1 kV GN-YE conductor, 3 cores and above DIN EN 60332-3, IEC 60332-3 (previously
Test voltage 4000 V in the outer layer DIN VDE 0472 part 804 test method C)
Coupling resistance Cores stranded in layers with Self-extinguishing and flame-resistant
max. 250 Ohm/km optimal lay-length acc. to DIN VDE 0482 Part 265-2-1/
Minimum bending radius Inner sheath EN 50265-2-1/IEC 60332-1 (equivalent
flexing 15x cable Tinned copper braided screen, DIN VDE 0472 Part 804 test method B)
fixed installation 7,5x cable approx. 85% coverage Corrosiveness of corrosive gases
Radiation resistance Outer sheath of halogen-free polymer acc. to DIN VDE 0482 part 267,
up to 100x106 cJ/kg (up to 100 Mrad) compound type, TM7 to DIN EN 50267-2-2, IEC 607542
DIN VDE 0207-363-8 / DIN EN 50363-8 (equivalent DIN VDE 0472 part 813)
Sheath colour black (RAL 9005) Halogen-free acc. to DIN VDE 0482,
with meter marking Part 267, DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)
Note
G = with green-yellow conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JZ-600 HMH, confer page 91
Application
Halogen-free, flame retardant cables are used as measuring and control cable in machine tools, conveyor belts, production lines as well as in plant
installations, in heating and air-conditioning systems and steel production works. For fixed installation or flexible application, directed without forcing
by casual, constantly recurring free movements and without tensile stress, for medium mechanical strain. This cable is suitable for the application in
dry, damp and wet environments, outdoors (fixed installation) and for laying on plaster. The dense screening assures interference-free transmission
of all signals and impulses.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12850 3 G 0,5 8,8 45,0 150,0 20 12864 3G1 9,8 64,0 163,0 18
12851 4 G 0,5 9,4 54,0 170,0 20 12865 4G1 10,4 76,0 200,0 18
12852 5 G 0,5 10,2 66,0 199,0 20 12866 5G1 11,4 89,0 239,0 18
12853 7 G 0,5 10,8 79,0 235,0 20 12867 7G1 12,3 114,0 289,0 18
12854 12 G 0,5 14,3 137,0 320,0 20 12868 12 G 1 15,9 186,0 464,0 18
12855 18 G 0,5 16,4 156,0 428,0 20 12869 18 G 1 18,2 284,0 628,0 18
12856 25 G 0,5 19,3 250,0 503,0 20 12870 25 G 1 22,0 387,0 855,0 18
12857 3 G 0,75 9,1 57,0 155,0 19 12871 3 G 1,5 10,8 82,0 187,0 16
12858 4 G 0,75 9,9 63,0 190,0 19 12872 4 G 1,5 11,5 99,0 240,0 16
12859 5 G 0,75 10,6 76,0 228,0 19 12873 5 G 1,5 13,0 123,0 289,0 16
12860 7 G 0,75 11,5 100,0 323,0 19 12874 7 G 1,5 14,2 148,0 383,0 16
12861 12 G 0,75 14,9 175,0 410,0 19 12875 12 G 1,5 18,4 274,0 592,0 16
12862 18 G 0,75 17,2 240,0 560,0 19 12876 18 G 1,5 21,3 386,0 806,0 16
12863 25 G 0,75 20,6 306,0 730,0 19 12877 25 G 1,5 25,4 531,0 1241,0 16
Continuation
100
Flexible Control Cables / Halogen-free Control Cables
JZ-600 HMH-C flexible control cable, halogen-free, extremely fire resistant, oil
resistant , 0,6/1kV, screened, EMC-preferred type, meter marking
1)
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
12878 3 G 2,5 12,8 148,0 298,0 14 12894 4 G 16 25,7 807,0 1395,0 6
12879 4 G 2,5 13,8 169,0 345,0 14 12895 5 G 16 28,5 940,0 1870,0 6
12880 5 G 2,5 15,0 220,0 427,0 14 12896 7 G 16 31,4 1345,0 2720,0 6
12881 7 G 2,5 16,3 284,0 561,0 14 12897 3 G 25 28,2 920,0 2465,0 4
12882 12 G 2,5 21,6 470,0 857,0 14 12898 4 G 25 31,3 1169,0 2750,0 4
12883 18 G 2,5 25,2 572,0 1355,0 14 12899 5 G 25 34,5 1420,0 3490,0 4
12884 25 G 2,5 30,0 740,0 1995,0 14 12900 3 G 35 31,2 1250,0 3230,0 2
12885 3G4 14,6 178,0 391,0 12 12901 4 G 35 34,5 1680,0 4100,0 2
12886 4G4 15,7 234,0 527,0 12 12902 5 G 35 38,0 2020,0 4950,0 2
12887 5G4 17,2 284,0 700,0 12 12903 4 G 50 40,5 2370,0 5780,0 1
12888 3G6 15,9 245,0 629,0 10 12904 4 G 70 46,0 3257,0 7480,0 2/0
12889 4G6 17,4 316,0 731,0 10 12905 4 G 95 51,3 4060,0 10220,0 3/0
12890 5G6 19,2 442,0 1105,0 10 12906 4 G 120 56,4 5231,0 13750,0 4/0
12891 3 G 10 19,8 367,0 1125,0 8 12907 4 G 150 64,4 6794,0 15900,0 4/0
12892 4 G 10 21,5 549,0 1345,0 8
12893 5 G 10 23,5 604,0 1635,0 8
101
Flexible Control Cables / Halogen-free Control Cables
adapted to DIN VDE 0285-525-2-51 / DIN VDE 0295 cl.5, fine-wire, consultation
DIN EN 50525-2-51 and BS 6360 cl.5, IEC 60228 cl.5 The materials used in manufacture are
DIN VDE 0285-525-3-11 / Core insulation of halogen-free polymer cadmium-free and contain no silicone
DIN EN 50525-3-11 compound type TI6 to and free from substances harmful to
Temperature range DIN VDE 0207-363-7 / DIN EN 50363-7 the wetting properties of lacquers
flexing -15C to +70C Core identification to DIN VDE 0293-308 Tests
fixed installation -40C to +70C GN-YE conductor Flame test acc. to
Nominal voltage U0/U 450/750 V Cores stranded in layers with DIN VDE 0482-332-3, BS 4066 part 3,
Test voltage 3000 V optimal lay-length DIN EN 60332-3, IEC 60332-3 (previously
Coupling resistance Separating foil DIN VDE 0472 part 804 test method C)
max. 250 Ohm/km Tinned copper braided screen, Self-extinguishing and flame retardant
Minimum bending radius approx. 85% coverage acc. to DIN VDE 0482-332-1-2,
flexing 12,5x cable Outer sheath of halogen-free polyner DIN EN 60332-1-2 / IEC 60332-1
fixed installation 4x cable compound type TM7 to (equivalent DIN VDE 0472 part 804
Radiation resistance DIN VDE 0207-363-8 / DIN EN 50363-8 test method B)
up to 100x106 cJ/kg (up to 100 Mrad) Sheath colour grey (RAL 7001) Corrosiveness of combustion gases
with meter marking acc. to DIN VDE 0482 part 267/
LS0H= Low Smoke Zero Halogen DIN EN 50267-2-2/ IEC 60754-2
(equivalent DIN VDE 0472 part 813)
Halogen-free acc. to DIN VDE 0482
part 267/DIN EN 50267-2-1/ IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density acc. to DIN VDE 0482
part 1034-1+2, DIN EN 61034-1+2,
IEC 61034-1+2, BS 7622 part 1+2
(previously DIN VDE 0472 part 816)
Note
G = with green-yellow conductor
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified" when
ordering.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
JB-750 HMH, confer page 93
Application
Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts,
production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for
casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable
for use in dry, damp and wet environments and for installation on plaster An interference-free transmission of signals and pulse in assured by the high
degree of screening.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
11942 3 G 1,5 8,4 80,0 125,0 16 11948 3G4 12,1 174,0 251,0 12
11943 4 G 1,5 9,3 97,0 160,0 16 11949 4G4 13,3 230,0 315,0 12
11944 5 G 1,5 10,2 119,0 193,0 16 11950 5G4 14,7 273,0 396,0 12
11945 3 G 2,5 9,9 144,0 198,0 14 11951 4G6 15,0 305,0 430,0 10
11946 4 G 2,5 11,0 148,0 240,0 14 11952 5G6 16,6 439,0 524,0 10
11947 5 G 2,5 12,2 181,0 280,0 14
Continuation
102
Flexible Control Cables / Halogen-free Control Cables
103
INHERENTLY SAFE PVC CONTROL CABLES
Flexible Control Cables / PVC Control Cables for Intrinsically Safe Circuits
Application
For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the requirements
for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Those cables are not suitable for
underground laying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
14001 2 x 0,75 5,3 14,4 46,0 19 14019 2 x 1,5 6,4 29,0 70,0 16
14002 3 x 0,75 5,6 21,6 54,0 19 14020 3 x 1,5 6,8 43,0 90,0 16
14003 4 x 0,75 6,3 29,0 66,0 19 14021 4 x 1,5 7,4 58,0 109,0 16
14004 5 x 0,75 6,9 36,0 80,0 19 14022 5 x 1,5 8,3 72,0 131,0 16
14075 7 x 0,75 7,5 52,0 110,0 19 14023 7 x 1,5 9,2 101,0 184,0 16
14005 8 x 0,75 8,3 58,0 130,0 19 14024 12 x 1,5 11,8 173,0 309,0 16
14076 12 x 0,75 9,8 88,0 179,0 19 14025 18 x 1,5 14,6 259,0 440,0 16
14006 18 x 0,75 12,2 130,0 257,0 19 14026 25 x 1,5 17,4 360,0 620,0 16
14007 25 x 0,75 14,3 180,0 365,0 19 14027 30 x 1,5 18,6 440,0 842,0 16
14008 30 x 0,75 15,3 215,0 448,0 19 14100 3 x 2,5 8,3 72,0 148,0 14
14009 34 x 0,75 16,5 245,0 510,0 19 14101 4 x 2,5 9,2 96,0 178,0 14
14010 41 x 0,75 18,1 298,0 607,0 19 14102 5 x 2,5 10,1 120,0 221,0 14
14011 2x1 5,6 19,0 60,0 18
14012 3x1 5,9 29,0 72,0 18
14013 4x1 6,6 38,0 86,0 18
14014 5x1 7,3 48,0 104,0 18
14015 7x1 8,1 67,0 141,0 18
14016 12 x 1 10,4 115,0 230,0 18
14017 18 x 1 12,9 173,0 343,0 18
14018 25 x 1 15,4 240,0 485,0 18
105
Flexible Control Cables / PVC Control Cables for Intrinsically Safe Circuits
Application
For hazardous areas the cables with special marking (blue) (hazard type-i-) used as flexible control and measuring cables to meet the requirements
for the installation of electrical apparatus. These installations are not earthed and require a separate power circuit. Those cables are not suitable for
underground laying. The copper braided screening ensures the transmission of data signals and free from interference.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
14028 2 x 0,75 6,1 40,0 59,0 19 14050 2 x 1,5 7,0 63,0 88,0 16
14029 3 x 0,75 6,3 52,0 66,0 19 14051 3 x 1,5 7,4 80,0 100,0 16
14030 4 x 0,75 6,8 60,0 77,0 19 14052 4 x 1,5 8,1 97,0 126,0 16
14031 5 x 0,75 7,4 71,0 93,0 19 14053 5 x 1,5 9,0 119,0 160,0 16
14088 7 x 0,75 8,2 91,0 130,0 19 14054 7 x 1,5 9,8 147,0 208,0 16
14032 8 x 0,75 9,0 110,0 145,0 19 14055 12 x 1,5 12,8 267,0 338,0 16
14033 10 x 0,75 10,3 137,0 180,0 19 14056 18 x 1,5 15,6 374,0 479,0 16
14034 12 x 0,75 10,5 142,0 202,0 19 14057 25 x 1,5 18,4 526,0 705,0 16
14035 18 x 0,75 12,7 212,0 292,0 19 14058 30 x 1,5 19,6 555,0 830,0 16
14036 20 x 0,75 13,6 238,0 362,0 19 14059 34 x 1,5 21,2 629,0 900,0 16
14037 25 x 0,75 15,0 281,0 415,0 19
14038 30 x 0,75 16,0 320,0 486,0 19
14039 34 x 0,75 17,2 345,0 523,0 19
14040 41 x 0,75 18,1 400,0 680,0 19
14041 2x1 6,4 50,0 65,0 18
14042 3x1 6,7 60,0 81,0 18
14043 4x1 7,2 71,0 98,0 18
14044 5x1 8,0 88,0 127,0 18
14045 7x1 8,7 111,0 158,0 18
14046 12 x 1 11,4 184,0 260,0 18
14047 18 x 1 13,6 260,0 380,0 18
14048 25 x 1 16,2 349,0 534,0 18
14049 34 x 1 18,5 486,0 741,0 18
106
Flexible Control Cables / PVC Control Cables for Intrinsically Safe Circuits
Application
For hazardous areas this flexible control cable has been constructed for closed circuit systems in accordance with VDE 0165 part 1, part 12. 2. 2. 6,
which covers the requirements for the special marking (blue) of this type (hazard type -i-). The paired construction and the copper screening afford
a good protection against electrical interference and ensure the transmission of data signals.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
14077 2 x 2 x 0,5 7,6 47,0 89,0 20 14089 2 x 2 x 0,75 8,6 60,0 105,0 19
14078 3 x 2 x 0,5 8,2 67,0 104,0 20 14090 3 x 2 x 0,75 9,1 80,0 128,0 19
14079 4 x 2 x 0,5 9,0 80,0 126,0 20 14091 4 x 2 x 0,75 10,1 110,0 156,0 19
14080 6 x 2 x 0,5 10,9 108,0 171,0 20 14092 6 x 2 x 0,75 12,4 142,0 216,0 19
14081 8 x 2 x 0,5 12,3 129,0 251,0 20 14093 8 x 2 x 0,75 14,2 200,0 309,0 19
14082 10 x 2 x 0,5 14,2 172,0 282,0 20 14094 10 x 2 x 0,75 16,0 238,0 355,0 19
14083 12 x 2 x 0,5 14,7 235,0 261,0 20 14095 12 x 2 x 0,75 16,8 270,0 405,0 19
14084 16 x 2 x 0,5 16,3 301,0 445,0 20 14096 16 x 2 x 0,75 18,6 342,0 560,0 19
14085 20 x 2 x 0,5 17,7 343,0 525,0 20 14097 20 x 2 x 0,75 21,2 369,0 671,0 19
14086 24 x 2 x 0,5 20,2 394,0 590,0 20 14098 24 x 2 x 0,75 22,8 451,0 795,0 19
14087 25 x 2 x 0,5 20,6 406,0 622,0 20 14099 25 x 2 x 0,75 23,2 461,0 803,0 19
107
BIO-OIL & MICROBE-RESISTANT CABLES
Flexible Control Cables / Bio-Oil and microbial resistant Cables
Application
HELUKABEL BIOFLEX-500-JZ is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance to
Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as in the steel industry
for difficult and problem areas. The high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25620 2 x 0,5 5,4 9,6 45,0 20 25654 2 x 1,5 7,2 29,0 68,0 16
25621 3 G 0,5 5,9 14,4 55,0 20 25655 3 G 1,5 7,6 43,0 87,0 16
25622 4 G 0,5 6,3 19,0 65,0 20 25656 4 G 1,5 8,2 58,0 106,0 16
25623 5 G 0,5 6,9 24,0 75,0 20 25657 5 G 1,5 9,0 72,0 131,0 16
25624 7 G 0,5 7,8 33,6 90,0 20 25658 7 G 1,5 10,7 101,0 173,0 16
25625 10 G 0,5 9,6 48,0 120,0 20 25659 10 G 1,5 13,0 144,0 245,0 16
25626 12 G 0,5 10,0 58,0 135,0 20 25660 12 G 1,5 13,4 173,0 293,0 16
25627 14 G 0,5 10,3 67,0 170,0 20 25661 14 G 1,5 14,5 202,0 347,0 16
25628 18 G 0,5 11,5 86,0 205,0 20 25662 18 G 1,5 16,0 259,0 454,0 16
25629 25 G 0,5 13,6 120,0 270,0 20 25663 25 G 1,5 19,5 360,0 641,0 16
25630 2 x 0,75 5,4 14,4 44,0 19 25664 42 G 1,5 23,8 605,0 1100,0 16
25631 3 G 0,75 6,2 21,6 53,0 19 25665 2 x 2,5 8,6 48,0 110,0 14
25632 4 G 0,75 6,7 29,0 64,0 19 25666 3 G 2,5 9,3 72,0 146,0 14
25633 5 G 0,75 7,3 36,0 76,0 19 25667 4 G 2,5 10,3 96,0 183,0 14
25634 7 G 0,75 8,8 50,0 96,0 19 25668 5 G 2,5 11,5 120,0 222,0 14
25635 10 G 0,75 10,5 72,0 140,0 19 25669 7 G 2,5 13,4 168,0 293,0 14
25636 12 G 0,75 11,0 86,0 170,0 19 25670 12 G 2,5 17,0 288,0 512,0 14
25637 14 G 0,75 11,4 101,0 202,0 19 25671 18 G 2,5 20,0 432,0 740,0 14
25638 18 G 0,75 12,6 130,0 260,0 19 25672 25 G 2,5 24,1 600,0 940,0 14
25639 25 G 0,75 15,2 180,0 282,0 19 25673 2x4 10,4 77,0 147,0 12
25640 41 G 0,75 18,0 296,0 600,0 19 25674 3G4 11,2 115,0 228,0 12
25641 42 G 0,75 18,5 310,0 620,0 19 25675 4G4 12,5 154,0 291,0 12
25642 2x1 6,6 19,0 53,0 18 25676 5G4 13,8 192,0 355,0 12
25643 3G1 7,0 29,0 63,0 18 25677 3G6 13,0 173,0 362,0 10
25644 4G1 7,6 38,0 75,0 18 25678 4G6 14,7 230,0 468,0 10
25645 5G1 8,2 48,0 89,0 18 25679 5G6 16,0 288,0 570,0 10
25646 7G1 9,6 67,0 115,0 18 25680 3 G 10 16,7 288,0 555,0 8
25647 10 G 1 11,6 96,0 166,0 18 25681 4 G 10 18,3 384,0 720,0 8
25648 12 G 1 12,0 115,0 201,0 18 25682 5 G 10 20,5 480,0 894,0 8
25649 14 G 1 13,2 134,0 230,0 18 25683 4 G 16 21,1 614,0 1063,0 6
25650 18 G 1 14,5 173,0 289,0 18 25684 5 G 16 23,6 768,0 1400,0 6
25651 25 G 1 17,6 240,0 380,0 18 25685 4 G 25 29,4 960,0 1590,0 4
25652 41 G 1 21,1 394,0 720,0 18 25686 4 G 35 32,8 1344,0 2200,0 2
25653 42 G 1 21,5 403,0 740,0 18 25687 4 G 50 38,9 1920,0 2400,0 1
25688 4 G 70 44,7 2688,0 4400,0 2/0
25689 4 G 95 59,6 3648,0 6000,0 3/0
25690 4 G 120 64,5 4608,0 7400,0 4/0
109
Flexible Control Cables / Bio-Oil and microbial resistant Cables
Application
HELUKABEL BIOFLEX-500-JZ-C is an extremely robust control cable with high abrasion and tear resistant properties. Due to its high resistance to
Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as in the steel industry
for difficult and problem areas. The inner sheaths of those cables raise the mecanical stress. The high flexibility of this cable type makes it quick and
easy to install. Suitable for outdoor lying. These screened cables are particularly suitable for the interference-free transmission in instrumentation and
control engineering applications (electromagnetic compatibillity). 1) For the critical applications we advise for consultation.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25691 2 x 0,5 6,6 41,0 68,0 20 25713 2x1 8,1 54,0 98,0 18
25692 3 G 0,5 7,1 45,0 84,0 20 25714 3G1 8,5 64,0 102,0 18
25693 4 G 0,5 7,6 54,0 95,0 20 25715 4G1 9,0 76,0 145,0 18
25694 5 G 0,5 8,2 66,0 107,0 20 25716 5G1 9,9 89,0 170,0 18
25695 7 G 0,5 9,4 79,0 135,0 20 25717 7G1 11,6 114,0 220,0 18
25696 10 G 0,5 11,2 107,0 170,0 20 25718 10 G 1 14,0 156,0 330,0 18
25697 12 G 0,5 11,3 137,0 195,0 20 25719 12 G 1 14,4 186,0 350,0 18
25698 14 G 0,5 11,9 142,0 222,0 20 25720 14 G 1 15,0 198,0 402,0 18
25699 18 G 0,5 12,9 156,0 278,0 20 25721 18 G 1 17,0 284,0 515,0 18
25700 25 G 0,5 15,9 250,0 406,0 20 25722 25 G 1 20,6 387,0 690,0 18
25701 2 x 0,75 7,2 46,0 88,0 19 25723 41 G 1 25,0 578,0 1070,0 18
25702 3 G 0,75 7,7 57,0 98,0 19 25724 42 G 1 25,5 590,0 1096,0 18
25703 4 G 0,75 8,2 63,0 112,0 19 25725 2 x 1,5 8,5 64,0 130,0 16
25704 5 G 0,75 8,8 76,0 130,0 19 25726 3 G 1,5 8,9 82,0 152,0 16
25705 7 G 0,75 10,1 100,0 185,0 19 25727 4 G 1,5 9,7 99,0 167,0 16
25706 10 G 0,75 12,2 140,0 270,0 19 25728 5 G 1,5 10,8 123,0 203,0 16
25707 12 G 0,75 12,3 175,0 294,0 19 25729 7 G 1,5 12,5 148,0 305,0 16
25708 14 G 0,75 13,0 190,0 317,0 19 25730 10 G 1,5 15,1 198,0 422,0 16
25709 18 G 0,75 14,6 240,0 357,0 19 25731 12 G 1,5 15,5 274,0 435,0 16
25710 25 G 0,75 17,8 306,0 510,0 19 25732 14 G 1,5 16,1 294,0 480,0 16
25711 41 G 0,75 21,5 403,0 951,0 19 25733 18 G 1,5 18,6 386,0 642,0 16
25712 42 G 0,75 22,0 410,0 975,0 19 25734 25 G 1,5 22,1 531,0 803,0 16
Continuation
110
Flexible Control Cables / Bio-Oil and microbial resistant Cables
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
A
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25735 41 G 1,5 27,2 840,0 1360,0 16 25748 4G6 17,0 316,0 560,0 10
25736 42 G 1,5 27,5 890,0 1375,0 16 25749 5G6 18,6 442,0 700,0 10
25737 2 x 2,5 10,6 110,0 180,0 14 25750 3 G 10 19,5 367,0 750,0 8
25738 3 G 2,5 11,1 148,0 215,0 14 25751 4 G 10 21,5 549,0 1023,0 8
25739 4 G 2,5 12,1 169,0 268,0 14 25752 5 G 10 23,9 604,0 1114,0 8
25740 5 G 2,5 13,2 220,0 349,0 14 25753 4 G 16 24,6 807,0 1385,0 6
25741 7 G 2,5 15,9 284,0 406,0 14 25754 5 G 16 27,3 940,0 1550,0 6
25742 12 G 2,5 19,5 470,0 720,0 14 25755 4 G 25 30,6 1169,0 1894,0 4
25743 2x4 12,6 124,0 300,0 12 25756 4 G 35 36,9 1680,0 2395,0 2
25744 3G4 13,4 178,0 340,0 12 25757 4 G 50 41,3 2370,0 3312,0 1
25745 4G4 15,0 234,0 408,0 12 25758 4 G 70 48,8 3257,0 4605,0 2/0
25746 5G4 16,4 284,0 504,0 12 25759 4 G 95 61,8 4060,0 6055,0 3/0
25747 3G6 15,2 245,0 453,0 10 25760 4 G 120 65,7 5231,0 7318,0 4/0
111
Flexible Control Cables / microbial resistant Cables
Application
Extremly robust universal cable. This cable is specially installed in rubbish, sewage-treatment plants, composting works, animal stalls and greenhouses.
Suitable for installation for flexible use for medium mechanical, stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms as well as outside.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
26125 2 x 0,5 4,8 9,6 41,0 20 26168 3 G 1,5 6,7 43,0 79,0 16
26126 3 G 0,5 5,1 14,4 50,0 20 26169 4 G 1,5 7,3 58,0 98,0 16
26127 4 G 0,5 5,7 19,0 61,0 20 26170 5 G 1,5 8,2 72,0 112,0 16
26128 5 G 0,5 6,2 24,0 72,0 20 26171 7 G 1,5 9,8 101,0 159,0 16
26129 7 G 0,5 7,4 33,6 86,0 20 26172 12 G 1,5 12,1 173,0 280,0 16
26130 12 G 0,5 9,1 58,0 130,0 20 26173 18 G 1,5 14,5 259,0 420,0 16
26131 18 G 0,5 10,7 86,0 198,0 20 26174 20 G 1,5 15,2 288,0 480,0 16
26132 20 G 0,5 11,2 96,0 211,0 20 26175 25 G 1,5 17,8 360,0 604,0 16
26133 25 G 0,5 13,0 120,0 260,0 20 26176 34 G 1,5 19,8 490,0 812,0 16
26135 34 G 0,5 14,5 163,0 361,0 20 26177 42 G 1,5 21,4 605,0 1002,0 16
26136 42 G 0,5 15,8 202,0 405,0 20 26178 50 G 1,5 23,7 720,0 1240,0 16
26137 50 G 0,5 17,3 240,0 541,0 20 26179 61 G 1,5 25,3 878,0 1421,0 16
26138 61 G 0,5 19,4 293,0 670,0 20 26180 2 x 2,5 7,6 48,0 99,0 14
26139 2 x 0,75 5,2 14,4 42,0 19 26181 3 G 2,5 8,3 72,0 136,0 14
26140 3 G 0,75 5,5 21,6 49,0 19 26182 4 G 2,5 9,1 96,0 170,0 14
26141 4 G 0,75 6,2 29,0 60,0 19 26183 5 G 2,5 10,2 120,0 204,0 14
26142 5 G 0,75 6,8 36,0 71,0 19 26184 7 G 2,5 12,1 168,0 281,0 14
26143 7 G 0,75 8,1 50,0 88,0 19 26185 12 G 2,5 15,2 288,0 487,0 14
26144 12 G 0,75 9,9 86,0 161,0 19 26186 18 G 2,5 18,1 432,0 704,0 14
26145 18 G 0,75 11,9 130,0 250,0 19 26187 25 G 2,5 22,2 600,0 909,0 14
26146 20 G 0,75 12,6 144,0 266,0 19 26189 3G4 9,9 115,0 224,0 12
26147 25 G 0,75 14,5 180,0 273,0 19 26190 4G4 11,0 154,0 289,0 12
26149 34 G 0,75 16,4 245,0 501,0 19 26191 5G4 12,1 192,0 357,0 12
26150 42 G 0,75 17,6 302,0 591,0 19 26192 7G4 13,3 269,0 451,0 12
26151 50 G 0,75 19,8 360,0 712,0 19 26193 12 G 4 18,3 461,0 782,0 12
26152 61 G 0,75 20,9 439,0 820,0 19 26195 3G6 11,7 173,0 345,0 10
26153 2x1 5,5 19,0 48,0 18 26196 4G6 13,0 230,0 417,0 10
26154 3G1 6,0 29,0 56,0 18 26197 5G6 14,5 288,0 521,0 10
26155 4G1 6,6 38,0 70,0 18 26198 7G6 16,0 403,0 622,0 10
26156 5G1 7,2 48,0 81,0 18 26199 3 G 10 15,0 288,0 537,0 8
26157 7G1 8,6 67,0 109,0 18 26200 4 G 10 16,8 384,0 699,0 8
26158 12 G 1 10,7 115,0 191,0 18 26201 5 G 10 18,7 480,0 851,0 8
26159 18 G 1 12,7 173,0 274,0 18 26202 7 G 10 20,6 672,0 1102,0 8
26160 20 G 1 13,5 192,0 314,0 18 26204 4 G 16 19,7 614,0 1028,0 6
26162 30 G 1 16,0 288,0 492,0 18 26206 7 G 16 24,4 1075,0 1772,0 6
26163 34 G 1 17,4 326,0 640,0 18 26208 4 G 25 25,2 960,0 1577,0 4
26164 42 G 1 18,9 403,0 804,0 18 26212 4 G 35 29,0 1344,0 2097,0 2
26165 50 G 1 21,0 480,0 932,0 18 26215 4 G 50 33,4 1920,0 2914,0 1
26166 61 G 1 22,2 586,0 1102,0 18 26216 5 G 50 37,2 2400,0 3919,0 1
26167 2 x 1,5 6,3 29,0 60,0 16
112
Flexible Control Cables / microbial resistant Cables
Application
Extremly robust universal cable. This cable is specially installed in rubbish, sewage-treatment plants, composting works, animal stalls and greenhouses.
The inner sheaths of those cables raise the mechanical stress. Suitable for installation for flexible use for medium mechanical, stresses with free
movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside. The high flexibility of this cable type makes it
quick and easy to install. This screened cable is ideal for use in data signal transmission free from interferences for measurement and control engineering
technology.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
26217 2 x 0,5 6,9 41,0 68,0 20 26245 2x1 7,9 54,0 98,0 18
26218 3 G 0,5 7,2 45,0 84,0 20 26246 3G1 8,2 64,0 102,0 18
26219 4 G 0,5 7,8 54,0 95,0 20 26247 4G1 8,9 76,0 145,0 18
26220 5 G 0,5 8,3 66,0 107,0 20 26248 5G1 9,5 89,0 171,0 18
26221 7 G 0,5 9,5 79,0 135,0 20 26249 7G1 11,0 114,0 210,0 18
26222 12 G 0,5 11,3 137,0 195,0 20 26250 12 G 1 13,1 186,0 330,0 18
26223 18 G 0,5 13,1 156,0 278,0 20 26251 18 G 1 15,4 284,0 488,0 18
26224 20 G 0,5 13,8 173,0 310,0 20 26252 20 G 1 16,0 325,0 545,0 18
26225 25 G 0,5 15,7 250,0 406,0 20 26253 25 G 1 18,3 387,0 690,0 18
26226 30 G 0,5 16,0 297,0 520,0 20 26254 30 G 1 18,8 457,0 770,0 18
26227 34 G 0,5 17,4 316,0 571,0 20 26255 34 G 1 20,3 500,0 811,0 18
26228 42 G 0,5 18,9 360,0 651,0 20 26256 42 G 1 21,8 590,0 996,0 18
26229 50 G 0,5 20,9 407,0 760,0 20 26257 50 G 1 24,0 681,0 1320,0 18
26230 61 G 0,5 22,9 520,0 911,0 20 26258 61 G 1 26,2 710,0 1480,0 18
26231 2 x 0,75 7,6 46,0 88,0 19 26259 2 x 1,5 8,4 64,0 130,0 16
26232 3 G 0,75 7,8 57,0 98,0 19 26260 3 G 1,5 9,0 82,0 154,0 16
26233 4 G 0,75 8,3 63,0 112,0 19 26261 4 G 1,5 9,6 99,0 165,0 16
26234 5 G 0,75 9,1 76,0 130,0 19 26262 5 G 1,5 10,5 123,0 197,0 16
26235 7 G 0,75 10,4 100,0 185,0 19 26263 7 G 1,5 12,1 148,0 305,0 16
26236 12 G 0,75 12,5 175,0 294,0 19 26264 12 G 1,5 14,9 274,0 435,0 16
26237 18 G 0,75 14,3 240,0 357,0 19 26265 18 G 1,5 17,1 386,0 642,0 16
26238 20 G 0,75 15,2 262,0 404,0 19 26266 20 G 1,5 18,0 401,0 718,0 16
26239 25 G 0,75 17,6 306,0 510,0 19 26267 25 G 1,5 20,7 531,0 803,0 16
26240 30 G 0,75 18,1 340,0 561,0 19 26268 30 G 1,5 21,1 598,0 961,0 16
26241 34 G 0,75 19,5 346,0 670,0 19 26269 34 G 1,5 22,7 671,0 1060,0 16
26242 42 G 0,75 20,9 410,0 960,0 19 26270 42 G 1,5 24,4 890,0 1300,0 16
26243 50 G 0,75 23,2 470,0 1104,0 19 26271 50 G 1,5 26,8 997,0 1677,0 16
26244 61 G 0,75 25,0 550,0 1270,0 19 26272 61 G 1,5 29,6 1120,0 1971,0 16
Continuation
113
Flexible Control Cables / microbial resistant Cables
114
HYGIENIC CABLE
Flexible Control Cables / Hygienic Cables
Application
Special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications in which
food and beverages are processed unpacked and unsealed, e. g. processing of dairy products, meat, fish; production of convenience foods, brewery
and beverage industry.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
27031 2 x 0,5 4,8 10,0 45,0 20 27061 4x1 6,6 38,0 75,0 18
27032 3 G 0,5 5,1 14,0 55,0 20 27062 5G1 7,3 48,0 89,0 18
27033 3 x 0,5 5,1 14,0 55,0 20 27063 5x1 7,3 48,0 89,0 18
27034 4 G 0,5 5,5 19,0 65,0 20 27064 7G1 8,1 67,0 115,0 18
27035 4 x 0,5 5,5 19,0 65,0 20 27065 7x1 8,1 67,0 115,0 18
27036 5 G 0,5 6,2 24,0 75,0 20 27066 10 G 1 9,8 96,0 166,0 18
27037 5 x 0,5 6,2 24,0 75,0 20 27067 12 G 1 10,4 115,0 201,0 18
27038 7 G 0,5 7,2 34,0 90,0 20 27068 18 G 1 12,9 173,0 289,0 18
27039 7 x 0,5 7,2 34,0 90,0 20 27069 25 G 1 15,4 240,0 380,0 18
27040 10 G 0,5 8,3 48,0 120,0 20 27070 2 x 1,5 6,4 29,0 68,0 16
27041 12 G 0,5 8,7 58,0 135,0 20 27071 3 G 1,5 6,8 43,0 87,0 16
27042 18 G 0,5 10,7 86,0 205,0 20 27072 3 x 1,5 6,8 43,0 87,0 16
27043 25 G 0,5 12,6 120,0 270,0 20 27073 4 G 1,5 7,4 58,0 106,0 16
27044 2 G 0,75 5,3 14,0 44,0 19 27074 4 x 1,5 7,4 58,0 106,0 16
27045 3 G 0,75 5,6 22,0 53,0 19 27075 5 G 1,5 8,3 72,0 131,0 16
27046 3 G 0,75 5,6 22,0 53,0 19 27076 5 x 1,5 8,3 72,0 131,0 16
27047 4 G 0,75 6,3 29,0 64,0 19 27077 7 G 1,5 10,9 101,0 173,0 16
27048 4 x 0,75 6,3 29,0 64,0 19 27078 7 x 1,5 10,9 101,0 173,0 16
27049 5 G 0,75 6,9 36,0 76,0 19 27079 12 G 1,5 11,8 173,0 293,0 16
27050 5 x 0,75 6,9 36,0 76,0 19 27080 18 G 1,5 14,6 259,0 454,0 16
27051 7 G 0,75 7,5 50,0 96,0 19 27081 25 G 1,5 17,4 360,0 641,0 16
27052 7 x 0,75 7,5 50,0 96,0 19 27082 2 x 2,5 7,8 48,0 110,0 14
27053 10 G 0,75 9,2 72,0 140,0 19 27083 3 G 2,5 8,3 72,0 146,0 14
27054 12 G 0,75 9,8 86,0 170,0 19 27084 4 G 2,5 9,2 96,0 183,0 14
27055 18 G 0,75 12,2 130,0 260,0 19 27085 5 G 2,5 10,1 120,0 222,0 14
27056 25 G 0,75 14,3 180,0 282,0 19 27086 7 G 2,5 11,2 168,0 293,0 14
27057 2x1 5,6 19,0 53,0 18 27087 12 G 2,5 14,8 288,0 512,0 14
27058 3G1 5,9 29,0 63,0 18 27088 4G4 10,9 154,0 291,0 12
27059 3x1 5,9 29,0 63,0 18 27089 5G4 12,1 192,0 355,0 12
27060 4G1 6,6 38,0 75,0 18
116
Flexible Control Cables / Hygienic Cables
Application
Screened special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications
in which food and beverages are processed unpacked and unsealed, e. g. processing of dairy products, meat, fish; production of convenience foods,
brewery and beverage industry.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
27105 2 x 0,5 5,7 35,0 47,0 20 27135 4G1 7,2 71,0 100,0 18
27107 3 G 0,5 5,9 42,0 57,0 20 27136 5x1 8,0 88,0 128,0 18
27106 3 x 0,5 5,9 42,0 57,0 20 27137 5G1 8,0 88,0 128,0 18
27108 4 G 0,5 6,4 47,0 60,0 20 27138 7x1 8,7 111,0 157,0 18
27109 4 x 0,5 6,4 47,0 60,0 20 27139 7G1 8,7 111,0 157,0 18
27110 5 x 0,5 6,9 56,0 75,0 20 27140 10 G 1 11,2 150,0 230,0 18
27111 5 G 0,5 6,9 56,0 75,0 20 27141 12 G 1 11,4 184,0 262,0 18
27112 7 G 0,5 7,6 69,0 97,0 20 27142 18 G 1 13,6 260,0 381,0 18
27113 7 x 0,5 7,6 69,0 97,0 20 27143 25 G 1 16,2 349,0 535,0 18
27114 10 G 0,5 9,6 94,0 133,0 20 27144 2 x 1,5 7,0 63,0 87,0 16
27115 12 G 0,5 9,7 108,0 158,0 20 27145 3 x 1,5 7,4 80,0 102,0 16
27116 18 G 0,5 11,5 145,0 218,0 20 27146 3 G 1,5 7,4 80,0 102,0 16
27117 25 G 0,5 13,7 240,0 315,0 20 27147 4 x 1,5 8,1 97,0 127,0 16
27118 2 x 0,75 6,1 40,0 60,0 19 27148 4 G 1,5 8,1 97,0 127,0 16
27119 3 x 0,75 6,3 52,0 67,0 19 27149 5 x 1,5 9,0 119,0 159,0 16
27120 3 G 0,75 6,3 52,0 67,0 19 27150 5 G 1,5 9,0 119,0 159,0 16
27121 4 G 0,75 6,8 60,0 76,0 19 27151 7 x 1,5 9,8 147,0 207,0 16
27122 4 x 0,75 6,8 60,0 76,0 19 27152 7 G 1,5 9,8 147,0 207,0 16
27123 5 x 0,75 7,4 71,0 92,0 19 27153 12 G 1,5 12,8 267,0 340,0 16
27124 5 G 0,75 7,4 71,0 92,0 19 27154 18 G 1,5 15,6 374,0 480,0 16
27125 7 G 0,75 8,2 91,0 131,0 19 27155 25 G 1,5 18,4 526,0 704,0 16
27126 7 x 0,75 8,2 91,0 131,0 19 27156 2 x 2,5 8,4 96,0 131,0 14
27127 10 G 0,75 10,3 137,0 180,0 19 27157 3 G 2,5 8,8 144,0 168,0 14
27128 12 G 0,75 10,5 142,0 204,0 19 27158 4 G 2,5 9,8 148,0 194,0 14
27129 18 G 0,75 12,7 212,0 290,0 19 27159 5 G 2,5 10,8 181,0 222,0 14
27130 25 G 0,75 15,0 281,0 413,0 19 27160 7 G 2,5 11,9 255,0 345,0 14
27131 2x1 6,4 50,0 66,0 18 27161 12 G 2,5 15,8 441,0 570,0 14
27132 3G1 6,7 60,0 82,0 18 27162 4G4 11,6 230,0 310,0 12
27133 3x1 6,7 60,0 82,0 18 27163 5G4 12,8 273,0 386,0 12
27134 4x1 7,2 71,0 100,0 18
117
Flexible Control Cables / Hygienic Cables
Application
Special PUR data cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications
in which food and beverages are processed unpacked and unsealed, e. g. processing of dairy products, meat, fish; production of convenience foods,
brewery and beverage industry.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
27164 2 x 0,14 3,5 3,0 13,0 26 27180 2 x 0,25 3,8 5,0 18,0 24
27165 3 x 0,14 3,7 4,0 16,0 26 27181 3 x 0,25 4,0 7,0 22,0 24
27166 4 x 0,14 3,9 5,0 19,0 26 27182 4 x 0,25 4,3 10,0 26,0 24
27167 5 x 0,14 4,3 7,0 22,0 26 27183 5 x 0,25 4,7 12,0 30,0 24
27168 6 x 0,14 4,6 8,0 25,0 26 27184 6 x 0,25 5,3 14,0 36,0 24
27169 7 x 0,14 4,6 9,0 28,0 26 27185 7 x 0,25 5,3 17,0 42,0 24
27170 8 x 0,14 5,5 11,0 35,0 26 27186 8 x 0,25 6,1 19,0 49,0 24
27171 10 x 0,14 5,9 13,0 41,0 26 27187 10 x 0,25 6,8 24,0 57,0 24
27172 12 x 0,14 6,1 16,0 48,0 26 27188 12 x 0,25 7,0 29,0 66,0 24
27173 14 x 0,14 6,3 19,0 53,0 26 27189 14 x 0,25 7,3 34,0 75,0 24
27174 16 x 0,14 6,9 22,0 59,0 26 27190 16 x 0,25 7,7 38,0 84,0 24
27175 18 x 0,14 7,2 24,0 65,0 26 27191 18 x 0,25 8,3 43,0 72,0 24
27176 20 x 0,14 7,5 27,0 70,0 26 27192 19 x 0,25 8,3 46,0 84,0 24
27177 21 x 0,14 7,6 28,0 77,0 26 27193 20 x 0,25 8,7 48,0 101,0 24
27178 24 x 0,14 8,5 32,0 87,0 26 27194 21 x 0,25 8,8 50,0 107,0 24
27179 25 x 0,14 8,6 34,0 91,0 26 27195 24 x 0,25 9,8 60,0 120,0 24
27196 25 x 0,25 10,0 61,0 132,0 24
Continuation
118
Flexible Control Cables / Hygienic Cables
119
Flexible Control Cables / Hygienic Cables
Application
Special PUR cable for the food and beverage industry; outer sheath with antimicrobial properties increases process reliability in all applications in which
food and beverages are processed unpacked and unsealed, e. g. processing of dairy products, meat, fish; production of convenience foods, brewery
and beverage industry.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
27235 1 x 0,14 2,6 6,0 16,0 26 27252 1 x 0,25 3,0 7,0 27,0 24
27236 2 x 0,14 3,9 12,0 20,0 26 27253 2 x 0,25 4,3 16,0 31,0 24
27237 3 x 0,14 4,0 13,0 27,0 26 27254 3 x 0,25 4,5 19,0 36,0 24
27238 4 x 0,14 4,3 15,0 32,0 26 27255 4 x 0,25 4,8 22,0 40,0 24
27239 5 x 0,14 4,7 16,0 37,0 26 27256 5 x 0,25 5,4 27,0 51,0 24
27240 6 x 0,14 5,2 18,0 42,0 26 27257 6 x 0,25 5,8 32,0 58,0 24
27241 7 x 0,14 5,2 19,0 48,0 26 27258 7 x 0,25 5,8 35,0 64,0 24
27242 8 x 0,14 5,9 21,0 55,0 26 27259 8 x 0,25 7,0 42,0 82,0 24
27243 10 x 0,14 6,5 29,0 65,0 26 27260 10 x 0,25 7,3 50,0 85,0 24
27244 12 x 0,14 6,7 31,0 77,0 26 27261 12 x 0,25 7,5 58,0 90,0 24
27245 14 x 0,14 6,9 32,0 79,0 26 27262 14 x 0,25 8,1 62,0 144,0 24
27246 16 x 0,14 7,3 43,0 89,0 26 27263 16 x 0,25 8,5 67,0 110,0 24
27247 18 x 0,14 7,6 51,0 103,0 26 27264 18 x 0,25 9,1 78,0 142,0 24
27248 20 x 0,14 8,3 55,0 116,0 26 27265 19 x 0,25 9,1 79,0 146,0 24
27249 21 x 0,14 8,4 56,0 120,0 26 27266 20 x 0,25 9,5 152,0 88,0 24
27250 24 x 0,14 8,9 62,0 131,0 26 27267 21 x 0,25 9,6 91,0 150,0 24
27251 25 x 0,14 9,1 61,0 136,0 26 27268 24 x 0,25 10,4 96,0 163,0 24
Continuation
120
Flexible Control Cables / Hygienic Cables
121
DATA & COMPUTER CABLES
ge
B
3
in
ta
d
E
VD eld 29
ng
x
xe
ex
VD
le U
ol
ed
R/ shi E 0
xi
p 0/
- fi
- fl
lv
./
fle
x
to U
ed
ve
no
H A ed / VD
-f
C)
C)
g ge
s-
us
CS REG
e n es /
(
tin lta
e
di
di
se
re
re
t
fre
ut tan
ra vo
r
n
ra
ra
co
tu
tu
E
ai
n-
pe l
or
sis
ra
ra
g
O na
A
d
ch
ge
in
in
pe
pe
re
do
re
i
ge
om
nd
nd
ag
lo
lo
re
V-
m
L/
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
Data & computer cables
DATAFLAMM
+5 to +70 -40 to +70 350 7.5x 7.5x X X 130
DATAPUR -C
-5 to +80 -40 to +80 350 10x 5x X X X X 144
DATAFLAMM -C-PAAR
+5 to +70 -40 to +70 350 7.5x 7.5x X X X 146
123
Data and Computer Cables
Application
These cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable
for open air, wherever the construction requirements call for a minimum outer diameter, TRONIC is the suitable cable to use. This applies especially
to such areas as tool making and machine industries as well as electronic, computer, measurement and control sectors.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
18001 2 x 0,14 3,5 2,7 13,0 26 18029 2 x 0,25 3,8 4,8 18,0 24
18002 3 x 0,14 3,7 4,0 16,0 26 18030 3 x 0,25 4,0 7,2 22,0 24
18003 4 x 0,14 3,9 5,4 19,0 26 18031 4 x 0,25 4,3 9,6 26,0 24
18004 5 x 0,14 4,3 6,7 22,0 26 18032 5 x 0,25 4,7 12,0 30,0 24
18005 6 x 0,14 4,6 8,1 25,0 26 18033 6 x 0,25 5,3 14,4 36,0 24
18006 7 x 0,14 4,6 9,4 28,0 26 18034 7 x 0,25 5,3 16,8 42,0 24
18007 8 x 0,14 5,5 10,7 35,0 26 18035 8 x 0,25 6,1 19,2 49,0 24
18008 10 x 0,14 5,9 13,4 41,0 26 18036 10 x 0,25 6,8 24,0 57,0 24
18009 12 x 0,14 6,1 16,1 48,0 26 18037 12 x 0,25 7,0 28,8 66,0 24
18010 14 x 0,14 6,3 18,8 53,0 26 18038 14 x 0,25 7,3 33,6 75,0 24
18011 16 x 0,14 6,9 21,5 59,0 26 18039 16 x 0,25 7,7 38,4 84,0 24
18012 18 x 0,14 7,2 24,2 65,0 26 18040 18 x 0,25 8,3 43,2 72,0 24
18013 20 x 0,14 7,5 26,9 70,0 26 18114 19 x 0,25 8,3 46,0 84,0 24
18014 21 x 0,14 7,6 28,2 77,0 26 18041 20 x 0,25 8,7 48,0 101,0 24
18015 24 x 0,14 8,5 32,3 87,0 26 18042 21 x 0,25 8,8 50,0 107,0 24
18117 25 x 0,14 8,6 33,6 91,0 26 18043 24 x 0,25 9,8 60,0 120,0 24
18016 27 x 0,14 8,7 36,3 97,0 26 18118 25 x 0,25 10,0 61,0 132,0 24
18017 30 x 0,14 8,9 40,3 108,0 26 18044 27 x 0,25 10,1 65,0 140,0 24
18018 32 x 0,14 9,3 43,0 114,0 26 18045 30 x 0,25 10,3 72,0 156,0 24
18019 36 x 0,14 9,8 48,4 126,0 26 18046 32 x 0,25 10,7 77,0 164,0 24
18020 40 x 0,14 10,4 54,0 139,0 26 18047 36 x 0,25 11,3 86,0 182,0 24
18021 42 x 0,14 10,5 56,0 146,0 26 18115 37 x 0,25 11,3 89,0 190,0 24
18022 44 x 0,14 11,1 59,0 153,0 26 18048 40 x 0,25 12,1 96,0 200,0 24
18023 48 x 0,14 11,2 65,0 164,0 26 18049 42 x 0,25 12,2 101,0 211,0 24
18024 52 x 0,14 11,5 70,0 173,0 26 18050 44 x 0,25 12,8 106,0 225,0 24
18025 56 x 0,14 11,8 75,0 187,0 26 18051 48 x 0,25 13,0 115,0 245,0 24
18026 61 x 0,14 12,1 82,0 204,0 26 18052 52 x 0,25 13,3 125,0 263,0 24
18027 80 x 0,14 14,1 108,0 280,0 26 18053 56 x 0,25 13,9 134,0 280,0 24
18028 100 x 0,14 15,6 135,0 370,0 26 18054 61 x 0,25 14,3 146,0 305,0 24
Continuation
124
Data and Computer Cables
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
18055 80 x 0,25 16,5 192,0 450,0 24 18085 2 x 0,5 4,6 9,6 40,0 20
B
18056 100 x 0,25 18,3 240,0 590,0 24 18086 3 x 0,5 4,9 14,4 46,0 20
18057 2 x 0,34 4,2 6,5 22,0 22 18087 4 x 0,5 5,5 19,2 55,0 20
18058 3 x 0,34 4,4 9,8 30,0 22 18088 5 x 0,5 6,0 24,0 64,0 20
18059 4 x 0,34 4,8 13,1 43,0 22 18089 6 x 0,5 6,7 28,8 73,0 20
18060 5 x 0,34 5,4 16,3 54,0 22 18090 7 x 0,5 6,7 33,6 81,0 20
18061 6 x 0,34 5,9 19,6 58,0 22 18091 8 x 0,5 7,8 38,4 97,0 20
18062 7 x 0,34 5,9 22,8 61,0 22 18092 10 x 0,5 8,6 48,0 116,0 20
18063 8 x 0,34 7,1 26,1 73,0 22 18093 12 x 0,5 8,7 58,0 135,0 20
18064 10 x 0,34 7,6 32,6 82,0 22 18103 16 x 0,5 10,0 77,0 168,0 20
18065 12 x 0,34 7,8 39,2 102,0 22 18101 20 x 0,5 11,3 96,0 213,0 20
18066 14 x 0,34 8,4 45,7 108,0 22 18094 24 x 0,5 12,7 116,0 241,0 20
18067 16 x 0,34 8,8 52,0 126,0 22 18102 30 x 0,5 13,4 144,0 303,0 20
18068 18 x 0,34 9,3 59,0 143,0 22 18095 40 x 0,5 15,8 192,0 391,0 20
18069 20 x 0,34 10,0 65,0 160,0 22 18104 2 x 0,75 5,3 14,4 47,0 19
18070 21 x 0,34 10,1 69,0 166,0 22 18097 3 x 0,75 5,6 21,6 54,0 19
18071 24 x 0,34 11,2 78,0 186,0 22 18098 4 x 0,75 6,1 29,0 66,0 19
18096 25 x 0,34 11,4 82,0 192,0 22 18099 5 x 0,75 6,9 36,0 80,0 19
18072 27 x 0,34 11,5 88,0 206,0 22 18100 7 x 0,75 7,5 50,0 110,0 19
18073 30 x 0,34 11,8 98,0 226,0 22 18105 8 x 0,75 8,9 58,0 125,0 19
18074 32 x 0,34 12,3 104,0 245,0 22 18106 10 x 0,75 9,2 72,0 148,0 19
18075 36 x 0,34 12,9 118,0 285,0 22 18107 12 x 0,75 9,8 86,0 176,0 19
18116 37 x 0,34 12,9 121,0 292,0 22 18108 16 x 0,75 11,4 115,0 220,0 19
18076 40 x 0,34 14,0 131,0 318,0 22 18109 20 x 0,75 12,7 144,0 276,0 19
18077 42 x 0,34 14,1 137,0 330,0 22 18110 2x1 5,6 19,2 56,0 18
18078 44 x 0,34 14,6 144,0 370,0 22 18111 3x1 5,9 29,0 71,0 18
18079 48 x 0,34 14,7 157,0 405,0 22 18112 2 x 1,5 6,3 29,0 75,0 16
18080 52 x 0,34 15,4 170,0 430,0 22 18113 3 x 1,5 6,8 43,0 90,0 16
18081 53 x 0,34 15,8 183,0 440,0 22
18082 61 x 0,34 16,3 199,0 610,0 22
18083 80 x 0,34 18,8 264,0 880,0 22
18084 100 x 0,34 21,0 327,0 1050,0 22
125
Data and Computer Cables
Application
These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but
not suitable for open air. PAAR-TRONIC is the perfect cable for use in areas where a small diameter is essential to complete wiring. E. g. as a control
and signal cable in measuring instruments, computers, signal transfer etc. This cable is suitable only for low load application.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
19001 1 x 2 x 0,14 3,6 2,7 20,0 26 19018 24 x 2 x 0,14 12,2 65,0 170,0 26
19002 2 x 2 x 0,14 4,6 5,4 25,0 26 19019 25 x 2 x 0,14 12,3 67,0 180,0 26
19003 3 x 2 x 0,14 5,1 8,0 31,0 26 19020 26 x 2 x 0,14 12,4 70,0 184,0 26
19004 4 x 2 x 0,14 5,5 10,7 38,0 26 19021 27 x 2 x 0,14 12,5 73,0 188,0 26
19005 5 x 2 x 0,14 6,3 13,4 45,0 26 19022 28 x 2 x 0,14 13,5 75,0 192,0 26
19006 6 x 2 x 0,14 6,7 16,1 50,0 26 19023 30 x 2 x 0,14 13,6 81,0 200,0 26
19007 7 x 2 x 0,14 6,7 18,8 57,0 26 19024 32 x 2 x 0,14 14,0 86,0 224,0 26
19008 8 x 2 x 0,14 7,6 21,5 64,0 26 19025 34 x 2 x 0,14 14,1 91,0 247,0 26
19009 10 x 2 x 0,14 8,5 26,9 78,0 26 19026 36 x 2 x 0,14 14,9 97,0 260,0 26
19010 11 x 2 x 0,14 9,0 29,5 86,0 26 19027 38 x 2 x 0,14 15,6 102,0 272,0 26
19011 12 x 2 x 0,14 9,1 32,3 94,0 26 19028 40 x 2 x 0,14 15,9 108,0 294,0 26
19012 14 x 2 x 0,14 9,8 37,6 105,0 26 19029 44 x 2 x 0,14 16,2 118,0 334,0 26
19013 15 x 2 x 0,14 10,1 40,3 108,0 26 19030 45 x 2 x 0,14 16,4 121,0 342,0 26
19014 16 x 2 x 0,14 10,2 43,0 110,0 26 19031 50 x 2 x 0,14 17,4 134,0 387,0 26
19015 18 x 2 x 0,14 10,6 48,4 119,0 26 19032 52 x 2 x 0,14 17,4 140,0 403,0 26
19016 20 x 2 x 0,14 10,8 54,0 130,0 26 19033 55 x 2 x 0,14 18,0 148,0 427,0 26
19017 22 x 2 x 0,14 11,7 59,0 150,0 26
Continuation
126
Data and Computer Cables
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
19034 1 x 2 x 0,25 4,0 5,0 32,0 24 19057 32 x 2 x 0,25 17,1 160,0 410,0 24
B
19035 2 x 2 x 0,25 5,4 10,0 37,0 24 19058 34 x 2 x 0,25 17,5 170,0 425,0 24
19036 3 x 2 x 0,25 5,9 15,0 47,0 24 19059 36 x 2 x 0,25 17,8 180,0 440,0 24
19037 4 x 2 x 0,25 6,8 20,0 58,0 24 19060 38 x 2 x 0,25 18,3 190,0 480,0 24
19038 5 x 2 x 0,25 7,7 25,0 70,0 24 19061 40 x 2 x 0,25 19,0 200,0 530,0 24
19039 6 x 2 x 0,25 8,4 30,0 80,0 24 19062 44 x 2 x 0,25 19,7 220,0 580,0 24
19040 7 x 2 x 0,25 8,4 35,0 89,0 24 19063 45 x 2 x 0,25 20,0 225,0 600,0 24
19041 8 x 2 x 0,25 8,7 40,0 99,0 24 19064 50 x 2 x 0,25 21,0 250,0 650,0 24
19042 10 x 2 x 0,25 10,3 50,0 114,0 24 19065 52 x 2 x 0,25 21,0 260,0 670,0 24
19043 11 x 2 x 0,25 10,4 55,0 126,0 24 19066 55 x 2 x 0,25 21,5 275,0 790,0 24
19044 12 x 2 x 0,25 10,5 60,0 137,0 24 19067 1 x 2 x 0,34 4,6 6,5 36,0 22
19045 14 x 2 x 0,25 11,4 70,0 161,0 24 19068 2 x 2 x 0,34 6,3 13,1 42,0 22
19046 15 x 2 x 0,25 11,7 75,0 174,0 24 19069 3 x 2 x 0,34 6,7 19,6 50,0 22
19047 16 x 2 x 0,25 12,0 80,0 187,0 24 19070 4 x 2 x 0,34 7,6 26,1 61,0 22
19048 18 x 2 x 0,25 12,6 90,0 212,0 24 19071 1 x 2 x 0,5 4,9 9,6 42,0 20
19049 20 x 2 x 0,25 13,4 100,0 234,0 24 19072 2 x 2 x 0,5 7,2 19,2 51,0 20
19050 22 x 2 x 0,25 14,2 110,0 250,0 24 19073 3 x 2 x 0,5 7,8 28,8 62,0 20
19051 24 x 2 x 0,25 14,9 120,0 280,0 24 19074 4 x 2 x 0,5 8,6 38,4 73,0 20
19052 25 x 2 x 0,25 15,0 125,0 300,0 24 19075 1 x 2 x 0,75 5,8 14,4 47,0 19
19053 26 x 2 x 0,25 15,1 130,0 320,0 24 19076 2 x 2 x 0,75 8,7 28,8 59,0 19
19054 27 x 2 x 0,25 15,2 135,0 330,0 24 19077 3 x 2 x 0,75 8,9 43,2 74,0 19
19055 28 x 2 x 0,25 16,0 140,0 345,0 24 19078 4 x 2 x 0,75 10,2 57,6 93,0 19
19056 30 x 2 x 0,25 16,2 150,0 370,0 24
127
Sensor-Actuator-Cables
Note
All cables can be delivered with UL/CSA
approval and Cu shield.
DESINA: Explanation: see introduction.
Application
For decentralised installation and control technology. These cables are used in connector systems for sensors and actuators. In combination with
injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element between the periphery and the PLC
in production systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also
in the entire manufacturing industry. While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now
field bus technology has made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. Moving the
I/O points to the system periphery enables significant reductions in installation costs.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
128
Sensor-Actuator-Cables
Application
These cables are used in connector systems for sensors an actuators. In combination with injected circular connectors and installed actuator-sensor
boxes, they constitute an important connecting element between the periphery and the PLC in production systems. The assembled cables offer attractive
opportunities for reducing costs, not only in the field of automation technology, but also in the entire manufacturing industry.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
129
Data and Computer Cables
Application
DATAFLAMM halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking
systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in
dry, damp and wet environments. PE-insulated-cores, compared with the conventional PVC-insulated cores, assure a remarkable and more favourable
capacitance values. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories,
trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath
produce neither corrosive nor toxic gases.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52300 2 x 0,14 3,3 2,6 14,0 26 52330 4 x 0,34 5,0 13,0 35,0 22
52301 3 x 0,14 3,5 4,0 17,0 26 52331 5 x 0,34 5,5 16,4 43,0 22
52302 4 x 0,14 3,7 5,3 19,0 26 52332 7 x 0,34 6,0 22,7 58,0 22
52303 5 x 0,14 4,0 6,6 23,0 26 52333 10 x 0,34 7,8 32,4 80,0 22
52304 6 x 0,14 4,3 7,9 25,0 26 52334 12 x 0,34 8,0 39,1 91,0 22
52305 7 x 0,14 4,3 9,2 27,0 26 52335 15 x 0,34 9,0 49,1 115,0 22
52306 8 x 0,14 4,6 10,3 30,0 26 52336 18 x 0,34 9,8 59,1 135,0 22
52307 10 x 0,14 5,4 13,2 38,0 26 52337 21 x 0,34 10,4 68,3 154,0 22
52308 12 x 0,14 5,7 16,0 45,0 26 52338 25 x 0,34 12,0 81,4 180,0 22
52309 15 x 0,14 6,1 20,1 57,0 26 52339 34 x 0,34 13,6 111,1 233,0 22
52310 18 x 0,14 6,7 23,7 65,0 26 52340 40 x 0,34 14,8 130,5 272,0 22
52311 21 x 0,14 7,0 27,9 76,0 26 52341 2 x 0,5 4,6 9,5 30,0 20
52312 25 x 0,14 7,8 33,4 88,0 26 52342 3 x 0,5 4,9 14,2 36,0 20
52313 30 x 0,14 8,2 39,3 98,0 26 52343 4 x 0,5 5,3 19,2 43,0 20
52314 34 x 0,14 8,8 45,5 111,0 26 52344 5 x 0,5 5,9 24,0 56,0 20
52315 40 x 0,14 9,5 53,6 139,0 26 52345 7 x 0,5 6,4 33,7 70,0 20
52316 50 x 0,14 10,5 64,9 764,0 26 52346 10 x 0,5 8,3 48,0 101,0 20
52317 2 x 0,25 3,8 4,7 18,0 24 52347 12 x 0,5 8,6 57,4 117,0 20
52318 3 x 0,25 4,0 7,1 21,0 24 52348 15 x 0,5 9,8 72,0 145,0 20
52319 4 x 0,25 4,3 9,5 26,0 24 52349 18 x 0,5 10,5 86,4 171,0 20
52320 5 x 0,25 4,7 12,0 31,0 24 52350 21 x 0,5 11,1 101,0 197,0 20
52321 7 x 0,25 5,1 16,6 40,0 24 52351 25 x 0,5 12,6 120,0 230,0 20
52322 10 x 0,25 6,4 24,0 56,0 24 52352 30 x 0,5 13,3 142,6 269,0 20
52323 12 x 0,25 6,6 28,6 64,0 24 52353 34 x 0,5 14,5 163,1 301,0 20
52324 15 x 0,25 7,4 36,0 80,0 24 52354 40 x 0,5 15,8 192,0 365,0 20
52430 18 x 0,25 7,9 43,2 90,0 24 52355 2 x 0,75 5,2 14,3 40,0 19
52431 21 x 0,25 8,6 50,4 105,0 24 52356 3 x 0,75 5,5 21,5 51,0 19
52325 25 x 0,25 9,4 59,8 121,0 24 52357 4 x 0,75 6,0 28,6 61,0 19
52326 34 x 0,25 11,0 81,3 168,0 24 52358 5 x 0,75 6,7 36,1 76,0 19
52327 40 x 0,25 12,0 96,0 196,0 24 52359 7 x 0,75 7,3 50,3 97,0 19
52328 2 x 0,34 4,4 6,4 25,0 22 52360 10 x 0,75 9,8 72,0 137,0 19
52329 3 x 0,34 4,7 9,7 30,0 22 52361 12 x 0,75 10,0 86,2 167,0 19
130
Data and Computer Cables
Application
These screened cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but not
suitable for open air, wherever the construction requirements call for a minimum outer diameter, TRONIC is the suitable cable to use. This applies
especially to such areas as tool making and machine industries as well as electronic, computer, measurement and control sectors. The extremely small
outer diameter make suitable for miniature plugs etc.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
20139 1 x 0,14 2,6 6,1 16,0 26 20015 24 x 0,14 8,9 62,0 131,0 26
20001 2 x 0,14 3,9 12,0 20,0 26 20091 25 x 0,14 9,1 61,0 136,0 26
20002 3 x 0,14 4,0 13,0 27,0 26 20016 27 x 0,14 9,2 65,0 142,0 26
20003 4 x 0,14 4,3 14,5 32,0 26 20017 30 x 0,14 9,5 69,0 157,0 26
20004 5 x 0,14 4,7 15,5 37,0 26 20018 32 x 0,14 9,9 76,0 163,0 26
20005 6 x 0,14 5,2 18,2 42,0 26 20019 36 x 0,14 10,2 83,0 182,0 26
20006 7 x 0,14 5,2 19,0 48,0 26 20020 40 x 0,14 11,1 88,0 209,0 26
20007 8 x 0,14 5,9 21,3 55,0 26 20021 42 x 0,14 11,2 94,0 217,0 26
20008 10 x 0,14 6,5 28,7 65,0 26 20022 44 x 0,14 11,5 110,0 226,0 26
20009 12 x 0,14 6,7 30,5 77,0 26 20023 48 x 0,14 11,7 115,0 240,0 26
20010 14 x 0,14 6,9 32,0 79,0 26 20024 52 x 0,14 12,3 124,0 270,0 26
20011 16 x 0,14 7,3 43,2 89,0 26 20025 56 x 0,14 12,5 132,0 320,0 26
20012 18 x 0,14 7,6 51,0 103,0 26 20026 61 x 0,14 12,8 146,0 370,0 26
20013 20 x 0,14 8,3 55,0 116,0 26 20027 80 x 0,14 14,7 226,0 510,0 26
20014 21 x 0,14 8,4 56,0 120,0 26 20028 100 x 0,14 16,3 267,0 580,0 26
Continuation
131
Data and Computer Cables
132
Data and Computer Cables
Application
These data control cables are used for flexible use with free movement without tensile stress or forced movements in dry, moist and wet rooms but
not suitable for open air. PAAR-TRONIC-CY is well suited for use in areas subject to signal interference. The high level of screening reduces substantially
the effects of electrical disturbances from parallel running wiring etc. The copper screening is also often used as an "earth". The twisted pairs conform
favourable cross-talk attenuation values.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21001 1 x 2 x 0,14 4,0 15,6 34,0 26 21006 6 x 2 x 0,14 7,2 48,5 86,0 26
21002 2 x 2 x 0,14 5,0 18,5 40,0 26 21007 7 x 2 x 0,14 7,2 51,1 91,0 26
21003 3 x 2 x 0,14 5,7 23,0 49,0 26 21008 8 x 2 x 0,14 8,2 53,7 97,0 26
21004 4 x 2 x 0,14 6,1 26,6 55,0 26 21009 10 x 2 x 0,14 9,1 59,0 109,0 26
21005 5 x 2 x 0,14 6,8 30,7 66,0 26 21010 12 x 2 x 0,14 9,6 66,0 141,0 26
Continuation
133
Data and Computer Cables
134
Data and Computer Cables
Application
PAAR-CY is ideal for use as a connecting cable for all areas involving measuring, control, regulation and signal transfer as well as for use in all fields
of data and impulse transmission. Especially suited for all areas of high electromagnetic activity, e. g. disturbances through parallel circuits.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
17023 2x2x1 9,5 82,0 135,0 18 17034 2 x 2 x 1,5 11,3 112,0 168,0 16
17024 3x2x1 10,0 103,0 160,0 18 17035 3 x 2 x 1,5 12,2 139,0 221,0 16
17025 4x2x1 11,0 132,0 197,0 18 17036 4 x 2 x 1,5 13,5 176,0 269,0 16
17026 5x2x1 12,3 161,0 253,0 18 17037 5 x 2 x 1,5 14,5 212,0 314,0 16
17027 6x2x1 13,4 188,0 295,0 18 17038 6 x 2 x 1,5 17,2 255,0 550,0 16
17028 8x2x1 14,7 240,0 410,0 18 17039 8 x 2 x 1,5 17,5 322,0 650,0 16
17029 10 x 2 x 1 16,4 282,0 518,0 18 17040 10 x 2 x 1,5 20,1 380,0 900,0 16
17030 12 x 2 x 1 18,2 324,0 601,0 18 17041 12 x 2 x 1,5 21,8 442,0 950,0 16
17031 16 x 2 x 1 19,0 412,0 990,0 18 17042 16 x 2 x 1,5 25,0 572,0 1100,0 16
17032 20 x 2 x 1 19,8 505,0 1400,0 18 17043 20 x 2 x 1,5 27,0 705,0 1700,0 16
17033 25 x 2 x 1 23,5 610,0 1600,0 18 17044 25 x 2 x 1,5 29,5 862,0 1900,0 16
135
Data and Computer Cables
Application
As a control and signal cable in electronics, instrumentation and control technology. Interference free transmission of data signals from peripheral
devices to information storage. Excellent connecting cable for mixing console, studio equipment, measuring and control technology. Reliable in process
control, in machining centers and safety engineering systems. These cables with copper screening are suitable for interference free data and signal
transmission in the measurement, control and regulation technology.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21065 2 x 2 x 0,14 7,6 31,0 95,0 26 21071 8 x 2 x 0,14 12,0 97,0 245,0 26
21066 3 x 2 x 0,14 8,4 34,0 105,0 26 21072 9 x 2 x 0,14 13,0 101,0 280,0 26
21067 4 x 2 x 0,14 9,9 45,0 140,0 26 21073 10 x 2 x 0,14 14,1 108,0 325,0 26
21068 5 x 2 x 0,14 10,4 58,0 160,0 26 21074 12 x 2 x 0,14 15,2 134,0 380,0 26
21069 6 x 2 x 0,14 11,0 67,0 185,0 26 21075 16 x 2 x 0,14 16,7 179,0 440,0 26
21070 7 x 2 x 0,14 11,0 78,0 230,0 26 21076 20 x 2 x 0,14 18,4 225,0 520,0 26
Continuation
136
Data and Computer Cables
137
Data and Computer Cables
fixed installation -30C to +80C Conductor construction: this solder-free connection technique, the
Conductor resistance (loop) at 20C 0,22 mm = 7x0,2 mm stranded conductor is crimped together with
0,22 mm max. 186 Ohm/km 0,34 mm = 7x0,25 mm a sleeve onto a contact pin without prior
0,34 mm max. 115 Ohm/km 0,5 mm = 7x0,3 mm stripping of the insulation material
0,5 mm max. 78,5 Ohm/km 1 mm = 7 x 0,42 mm The twisted-pair lay-up prevents electrical
1,0 mm max. 39,2 Ohm/km Core insulation of PE unbalances within the cable and this thus
Operating peak voltage max. 250 V compound type L/MD to effectively suppresses cross-talking effects
(not for heavy current installation purposes) DIN VDE 0819-103 /DIN EN 50290-2-23 The materials used in manufacture are
Test voltage Core identification (pair) to DIN 47100 cadmium-free and contain no silicone
core/core 2000 V Cores stranded in pairs with and free from substances harmful to
core/screen 1000 V optimal lay-length the wetting properties of lacquers
Insulation resistance min. 5 GOhm x km Pairs stranded in layers with Tests
Mutual capacitance at 800 Hz optimal lay-length PVC outer sheath self-extinguishing and
> 4 pairs max. 60 nF/km Foil wrapping flame retardant acc. to DIN VDE
4 pairs values extended by 20% Tinned copper braided screening, 0482-332-1-2,
Inductance approx. 0,66 mH/km coverage approx. 85% DIN EN 60332-1-2, IEC 60332-1 (equivalent
Line attenuation (approx. value) Outer sheath of special PVC DIN VDE 0472 part 804 test method B)
0,22 mm at 100 kHz 9,0 dB/km compound type TM2 to
0,34 mm at 100 kHz 6,6 dB/km DIN VDE 0207-363-4-1/DIN EN 50363-4-1 Note
0,50 mm at 100 kHz 6,0 dB/km Type . . . Yv with reinforced outer sheath At 0,22 mm is designed for applications
0,22 mm at 1 MHz 25,0 dB/km Sheath colour black with Sub-D connectors.
0,34 mm at 1 MHz 20,0 dB/km with meter marking Termi-Point registered trade mark AMP.
0,50 mm at 1 MHz 18,0 dB/km AWG sizes are approximate equivalent
Cross-talk attenuation values. The actual cross-section is in mm.
up to 1 MHz min. 50 dB
up to 10 MHz min. 40 dB
Minimum bending radius
flexing 12x cable
fixed installation 7,5x cable
Application
These PE-insulated data cables with twisted pairs are used in particular for the interference-free transmission of data and signals over longer distances.
The high transmission rates are particularly suitable for RS 422 and RS 485 interfaces. These cables are suitable for fixed installations as well as for
flexing applications, for free movement without forced motion and without tensile stress, in dry and moist environments. Yv black with reinforced
outer sheath, is suitable for installation in the ground and in open air.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21129 2 x 2 x 0,22 7,8 26,0 60,0 24 21141 2 x 2 x 0,5 9,8 49,0 90,0 20
21130 3 x 2 x 0,22 8,1 31,0 79,0 24 21142 3 x 2 x 0,5 10,4 60,0 126,0 20
21131 4 x 2 x 0,22 8,5 38,0 96,0 24 21143 4 x 2 x 0,5 11,2 73,0 146,0 20
21132 8 x 2 x 0,22 10,6 62,0 140,0 24 21144 8 x 2 x 0,5 13,9 124,0 246,0 20
21133 10 x 2 x 0,22 11,6 79,0 184,0 24 21145 10 x 2 x 0,5 16,0 155,0 292,0 20
21135 2 x 2 x 0,34 8,7 35,0 83,0 22 21146 2x2x1 10,8 81,0 141,0 18
21136 3 x 2 x 0,34 9,4 44,0 92,0 22 21147 3x2x1 11,5 102,0 170,0 18
21137 4 x 2 x 0,34 10,0 53,0 112,0 22 21148 4x2x1 12,0 130,0 203,0 18
21138 8 x 2 x 0,34 12,4 86,0 179,0 22 21149 8x2x1 16,1 240,0 261,0 18
21139 10 x 2 x 0,34 13,8 104,0 219,0 22 21150 10 x 2 x 1 17,2 282,0 287,0 18
138
Data and Computer Cables
Application
These PE-insulated data cables with twisted pairs are used in particular for the interference-free transmission of data and signals over longer distances.
The high transmission rates are particularly suitable for RS 422 and RS 485 interfaces. These cables are suitable for fixed installations as well as for
flexing applications, for free movement without forced motion and without tensile stress, in dry and moist environments but not in open air (Type
grey).
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
139
Data and Computer Cables
Application
These screened cables are used as connecting cable for signal, measuring, control and speaking purposes for example in Intercom systems, weighing
instruments, equipment for office works, computers and telecommunication equipment etc. The cable offers a flexible handling and installation. Due
to pair-twisting, the electrical unbalances of the cable itself can be reduced and cross-talk effects are avoided. The tinned copper screened braiding
serves as protection against outer high frequency influences (capacitance unbalance). The drain wire ensure an exact connection to the earth clamp.
The cables are suitable for fixed installation and flexible application, free-moving without tensile stress and without forced guiding operation in dry,
damp and wet places for medium mechanical stress.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15987 2 x 2 x 0,2 5,7 24,0 60,0 - 15994 10 x 2 x 0,2 10,2 108,0 150,0 -
15988 3 x 2 x 0,2 6,1 35,0 70,0 - 15995 12 x 2 x 0,2 10,9 125,0 180,0 -
15989 4 x 2 x 0,2 6,6 45,0 80,0 - 15996 16 x 2 x 0,2 12,3 144,0 210,0 -
15990 5 x 2 x 0,2 7,9 54,0 90,0 - 15997 18 x 2 x 0,2 13,1 155,0 230,0 -
15991 6 x 2 x 0,2 8,3 56,0 100,0 - 15998 20 x 2 x 0,2 13,2 216,0 250,0 -
15992 7 x 2 x 0,2 8,3 68,0 120,0 - 15999 24 x 2 x 0,2 15,0 228,0 330,0 -
15993 8 x 2 x 0,2 9,4 72,0 130,0 - 16000 32 x 2 x 0,2 16,6 269,0 400,0 -
140
Data and Computer Cables
TRONIC 1-CY each core individually screened, EMC-preferred type, meter marking
Application
The individually screened, flexible cable is ideal for use in data and impulse transfer in computers, communication systems and external units and
offers interference-free data flow for all measuring and command functions. This cable type is widely used in the machine and steel producing industries
as well as for traffic signals and data processing areas.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49501 3 x 0,25 6,5 18,0 40,0 24 49512 3 x 0,5 7,3 28,8 71,0 20
49502 4 x 0,25 7,2 24,0 45,0 24 49513 4 x 0,5 8,2 38,5 81,0 20
49503 5 x 0,25 8,0 30,0 56,0 24 49514 5 x 0,5 9,2 48,0 95,0 20
49504 7 x 0,25 8,8 42,0 70,0 24 49515 7 x 0,5 10,0 67,0 115,0 20
49505 8 x 0,25 10,0 48,0 87,0 24 49516 8 x 0,5 11,0 77,0 145,0 20
49506 10 x 0,25 11,3 60,0 90,0 24 49517 10 x 0,5 13,2 96,0 169,0 20
49507 12 x 0,25 12,0 72,0 95,0 24 49518 12 x 0,5 14,0 114,6 185,0 20
49508 16 x 0,25 13,1 96,0 115,0 24 49519 16 x 0,5 15,5 154,0 225,0 20
49509 24 x 0,25 16,0 144,0 170,0 24 49520 32 x 0,5 21,5 308,0 440,0 20
49510 32 x 0,25 18,5 192,0 210,0 24
49511 48 x 0,25 23,5 288,0 320,0 24
141
Data and Computer Cables
Application
TRONIC 2-CY is used in all areas of measuring and control technology requiring only 2 impulse transfer cores. This cable type is used mainly in the
machinery and industrial equipment fields as well as in the steel industry and in electronics.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49521 4 x 0,14 6,2 14,6 40,0 26 49531 4 x 0,5 7,6 34,0 100,0 20
49522 8 x 0,14 7,2 20,3 50,0 26 49532 8 x 0,5 11,6 53,2 150,0 20
49523 12 x 0,14 8,4 26,8 70,0 26 49533 12 x 0,5 11,9 72,4 190,0 20
49524 16 x 0,14 8,6 32,0 80,0 26 49534 16 x 0,5 12,5 91,6 240,0 20
49525 24 x 0,14 9,0 43,4 110,0 26 49535 24 x 0,5 15,3 130,0 310,0 20
49526 4 x 0,25 6,5 21,3 60,0 24
49527 8 x 0,25 8,0 31,0 90,0 24
49528 12 x 0,25 9,2 40,5 120,0 24
49529 16 x 0,25 9,6 50,1 140,0 24
49530 24 x 0,25 12,0 69,3 200,0 24
142
Data and Computer Cables
Application
This pair screened table type offers total interference-free data transfer and is ideal for use as a signal and control cable in combination with computers
and external units. The screening properties also make this cable type well suited for use as a connecting cable in sound studio equipment, measuring
and control sectors as well as proving a highly reliable cable for process-control and security systems. The copper screening assures a disturbance-free
data and signal transmission for measuring and control systems.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
21323 2 x 2 x 0,25 6,2 32,0 60,0 24 21355 2 x 2 x 0,5 8,3 58,0 96,0 20
21324 3 x 2 x 0,25 6,8 48,0 80,0 24 21356 3 x 2 x 0,5 9,2 87,0 136,0 20
21325 4 x 2 x 0,25 7,4 64,0 112,0 24 21357 4 x 2 x 0,5 10,2 116,0 187,0 20
21326 5 x 2 x 0,25 8,7 80,0 142,0 24 21370 2 x 2 x 0,75 9,2 76,0 132,0 19
21327 6 x 2 x 0,25 9,1 96,0 159,0 24 21371 3 x 2 x 0,75 10,1 114,0 178,0 19
21328 7 x 2 x 0,25 9,6 112,0 177,0 24 21372 4 x 2 x 0,75 11,2 152,0 243,0 19
21329 10 x 2 x 0,25 11,7 160,0 250,0 24 21373 5 x 2 x 0,75 12,7 190,0 312,0 19
21340 2 x 2 x 0,34 6,7 42,0 78,0 22 21385 2x2x1 9,6 86,0 142,0 18
21341 3 x 2 x 0,34 7,5 63,0 104,0 22 21386 3x2x1 10,8 130,0 189,0 18
21342 4 x 2 x 0,34 8,1 84,0 153,0 22 21387 4x2x1 11,9 149,0 275,0 18
21343 5 x 2 x 0,34 9,5 105,0 189,0 22
21344 7 x 2 x 0,34 10,1 147,0 238,0 22
21345 10 x 2 x 0,34 13,4 210,0 322,0 22
143
Data and Computer Cables
Application
The specific construction of DATAPUR-C makes this cable type ideal for use in all types of computer systems, office machinery, signal and control
units. DATAPUR-C proves its efficiency but also in the acoustic field in telecommunications, paging and intercom systems but also in the cradle of
technology and in the measuring and control technology.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52490 2 x 0,14 3,9 12,3 21,0 26 52512 2 x 0,34 4,9 17,0 33,0 22
52491 3 x 0,14 4,0 14,0 25,0 26 52513 3 x 0,34 5,1 20,7 42,0 22
52492 4 x 0,14 4,3 15,7 29,0 26 52514 4 x 0,34 5,5 24,7 48,0 22
52493 5 x 0,14 4,7 19,5 35,0 26 52515 5 x 0,34 6,0 30,1 57,0 22
52494 7 x 0,14 5,2 23,4 41,0 26 52516 7 x 0,34 6,6 38,2 77,0 22
52495 10 x 0,14 6,5 28,5 54,0 26 52517 10 x 0,34 8,4 63,1 111,0 22
52496 12 x 0,14 6,7 34,3 64,0 26 52518 12 x 0,34 8,6 74,2 128,0 22
52497 14 x 0,14 6,9 39,9 74,0 26 52519 14 x 0,34 9,0 85,3 144,0 22
52498 18 x 0,14 7,6 51,5 93,0 26 52520 18 x 0,34 10,1 107,4 175,0 22
52499 21 x 0,14 8,4 60,1 108,0 26 52521 21 x 0,34 10,9 124,1 200,0 22
52500 25 x 0,14 9,1 71,9 128,0 26 52522 25 x 0,34 12,0 147,0 233,0 22
52501 2 x 0,25 4,3 14,7 26,0 24 52523 2 x 0,5 5,3 23,2 38,0 20
52502 3 x 0,25 4,5 17,1 33,0 24 52524 3 x 0,5 5,6 30,1 51,0 20
52503 4 x 0,25 4,8 20,6 38,0 24 52525 4 x 0,5 6,4 35,4 58,0 20
52504 5 x 0,25 5,4 24,8 44,0 24 52526 5 x 0,5 6,9 52,6 77,0 20
52505 7 x 0,25 5,8 31,1 53,0 24 52527 7 x 0,5 7,3 65,3 93,0 20
52506 10 x 0,25 7,3 42,0 79,0 24 52528 10 x 0,5 9,6 88,8 134,0 20
52507 12 x 0,25 7,5 51,0 92,0 24 52529 12 x 0,5 9,7 101,9 155,0 20
52508 14 x 0,25 8,1 60,1 105,0 24 52530 14 x 0,5 10,2 115,1 175,0 20
52509 18 x 0,25 9,1 77,9 128,0 24 52531 18 x 0,5 11,5 141,2 214,0 20
52510 21 x 0,25 9,6 91,4 148,0 24 52532 21 x 0,5 12,1 161,1 245,0 20
52511 25 x 0,25 10,6 110,8 175,0 24 52533 25 x 0,5 13,7 187,9 285,0 20
144
Data and Computer Cables
Application
As a connecting and interconnecting cable for signaling, measuring, control and intercom purposes for the use in paging and intercom systems, clock
systems, weighing equipment and office machines. The cables can be laid on or under plaster, in dry, damp and wet rooms as well as masonry and
concrete. Areas of use are telecommunications and information processing systems in public buildings, laboratories, warehouses and other buildings
in which the release of halogens in the event of fire must be avoided. Due to the shielding without interference against foreign encoder or high-frequency
signals.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52365 2 x 0,14 3,7 12,4 21,0 26 52398 4 x 0,34 5,5 24,5 47,0 22
52366 3 x 0,14 3,9 14,0 25,0 26 52399 5 x 0,34 6,0 30,0 58,0 22
52367 4 x 0,14 4,1 15,8 26,0 26 52400 7 x 0,34 6,4 38,2 76,0 22
52368 5 x 0,14 4,4 19,5 32,0 26 52401 10 x 0,34 8,0 62,2 110,0 22
52369 7 x 0,14 4,7 23,4 39,0 26 52402 12 x 0,34 8,5 69,4 123,0 22
52370 10 x 0,14 5,9 28,4 54,0 26 52403 14 x 0,34 9,0 82,1 140,0 22
52371 12 x 0,14 6,0 31,4 69,0 26 52404 16 x 0,34 9,5 95,0 157,0 22
52372 14 x 0,14 6,4 37,5 76,0 26 52405 18 x 0,34 10,2 107,3 172,0 22
52373 16 x 0,14 6,7 43,4 82,0 26 52406 21 x 0,34 10,8 122,4 195,0 22
52374 18 x 0,14 7,0 51,4 90,0 26 52407 25 x 0,34 12,2 142,2 226,0 22
52375 21 x 0,14 7,4 61,8 102,0 26 52408 30 x 0,34 12,7 162,6 261,0 22
52376 25 x 0,14 8,3 76,0 121,0 26 52409 34 x 0,34 13,7 178,9 285,0 22
52377 30 x 0,14 8,6 92,7 146,0 26 52410 40 x 0,34 14,9 203,3 330,0 22
52378 34 x 0,14 9,4 121,0 167,0 26 52411 2 x 0,5 5,1 23,0 37,0 20
52379 40 x 0,14 10,2 126,1 170,0 26 52412 3 x 0,5 5,5 30,0 46,0 20
52380 2 x 0,25 4,3 14,6 23,0 24 52413 4 x 0,5 5,9 35,3 57,0 20
52381 3 x 0,25 4,5 17,0 28,0 24 52414 5 x 0,5 6,6 52,5 77,0 20
52382 4 x 0,25 4,8 20,6 34,0 24 52415 7 x 0,5 7,1 65,3 92,0 20
52384 5 x 0,25 5,2 24,7 42,0 24 52416 10 x 0,5 9,3 88,7 135,0 20
52385 7 x 0,25 5,6 31,2 49,0 24 52417 12 x 0,5 9,4 98,7 148,0 20
52386 10 x 0,25 7,2 42,1 81,0 24 52418 18 x 0,5 11,1 141,2 210,0 20
52387 12 x 0,25 7,3 47,5 88,0 24 52419 21 x 0,5 12,0 161,0 242,0 20
52388 14 x 0,25 7,9 52,7 100,0 24 52420 25 x 0,5 13,5 187,2 285,0 20
52389 16 x 0,25 8,3 58,1 113,0 24 52421 30 x 0,5 14,2 223,2 340,0 20
52390 18 x 0,25 9,1 78,0 126,0 24 52422 40 x 0,5 16,5 294,9 445,0 20
52391 21 x 0,25 9,5 94,3 144,0 24 52423 2 x 0,75 5,9 30,6 45,0 19
52392 25 x 0,25 10,6 116,5 164,0 24 52424 3 x 0,75 6,2 38,1 60,0 19
52393 30 x 0,25 11,1 132,2 191,0 24 52425 4 x 0,75 6,9 58,0 80,0 19
52394 34 x 0,25 11,9 144,6 214,0 24 52426 5 x 0,75 7,5 68,4 97,0 19
52395 40 x 0,25 13,0 163,3 245,0 24 52427 7 x 0,75 8,1 88,4 127,0 19
52396 2 x 0,34 4,8 16,9 31,0 22 52428 10 x 0,75 10,4 122,5 175,0 19
52397 3 x 0,34 5,1 20,6 38,0 22 52429 12 x 0,75 10,9 137,2 196,0 19
145
Data and Computer Cables
Application
Are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic
weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments as
well as in masonry and concrete. PE-insulated cores, compared with the conventional PVC-insulated cores, assure a remarkable and more favourable
capacitance values. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories,
trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. With screened braiding offers
interference-free signal transfer. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52435 2 x 2 x 0,14 4,7 22,5 37,0 26 52460 7 x 2 x 0,34 9,8 89,8 154,0 22
52436 3 x 2 x 0,14 5,1 25,6 47,0 26 52461 10 x 2 x 0,34 12,2 119,8 209,0 22
52437 4 x 2 x 0,14 5,8 39,1 66,0 26 52462 12 x 2 x 0,34 12,9 139,4 245,0 22
52438 5 x 2 x 0,14 6,3 45,3 76,0 26 52463 15 x 2 x 0,34 14,4 160,0 279,0 22
52439 6 x 2 x 0,14 6,8 51,4 87,0 26 52464 18 x 2 x 0,34 15,3 207,2 363,0 22
52440 7 x 2 x 0,14 6,8 54,2 94,0 26 52465 2 x 2 x 0,5 7,4 50,2 76,0 20
52441 10 x 2 x 0,14 8,9 68,7 119,0 26 52466 3 x 2 x 0,5 8,0 64,5 107,0 20
52442 12 x 2 x 0,14 9,2 78,3 135,0 26 52467 4 x 2 x 0,5 9,0 77,2 134,0 20
52443 15 x 2 x 0,14 10,0 79,9 157,0 26 52468 5 x 2 x 0,5 9,9 96,2 150,0 20
52444 18 x 2 x 0,14 11,0 99,2 190,0 26 52469 6 x 2 x 0,5 10,9 107,4 176,0 20
52445 2 x 2 x 0,25 5,7 27,1 44,0 24 52470 7 x 2 x 0,5 10,9 117,3 185,0 20
52446 3 x 2 x 0,25 6,2 42,4 66,0 24 52471 10 x 2 x 0,5 13,8 158,2 275,0 20
52447 4 x 2 x 0,25 7,0 54,5 81,0 24 52472 12 x 2 x 0,5 14,5 177,8 330,0 20
52448 5 x 2 x 0,25 7,9 59,8 98,0 24 52473 15 x 2 x 0,5 15,8 236,4 380,0 20
52449 6 x 2 x 0,25 8,6 64,6 116,0 24 52474 18 x 2 x 0,5 17,1 265,4 450,0 20
52450 7 x 2 x 0,25 8,6 71,3 120,0 24 52475 2 x 2 x 0,75 8,5 64,6 105,0 19
52451 10 x 2 x 0,25 10,6 93,3 153,0 24 52476 3 x 2 x 0,75 9,3 81,7 137,0 19
52452 12 x 2 x 0,25 11,4 108,0 175,0 24 52477 4 x 2 x 0,75 10,6 107,6 166,0 19
52453 15 x 2 x 0,25 12,5 123,4 213,0 24 52478 5 x 2 x 0,75 11,7 126,1 200,0 19
52454 18 x 2 x 0,25 13,1 139,7 248,0 24 52479 6 x 2 x 0,75 12,7 138,6 236,0 19
52455 2 x 2 x 0,34 6,5 43,3 68,0 22 52480 7 x 2 x 0,75 12,7 153,7 255,0 19
52456 3 x 2 x 0,34 7,2 55,0 92,0 22 52481 10 x 2 x 0,75 15,6 220,0 363,0 19
52457 4 x 2 x 0,34 7,9 64,0 110,0 22 52482 12 x 2 x 0,75 16,8 265,5 434,0 19
52458 5 x 2 x 0,34 8,8 74,5 128,0 22 52483 15 x 2 x 0,75 18,6 327,6 500,0 19
52459 6 x 2 x 0,34 9,8 85,0 147,0 22 52484 18 x 2 x 0,75 20,5 374,6 580,0 19
146
Data and Computer Cables
Application
Absolute disturbance-free data transfer both for installed terminals in all areas of medicine and data technology. Also suitable for use in machine tool
and steel producing industries, traffic signal systems, assembly lines and food processing.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
43553 2 x 2 x 0,5 8,7 50,0 101,0 20 43539 30 x 2 x 0,75 30,3 765,0 1210,0 19
43554 3 x 2 x 0,5 9,8 66,0 120,0 20 43559 2x2x1 12,3 72,0 130,0 18
43524 4 x 2 x 0,5 10,8 108,0 196,0 20 43560 3x2x1 13,4 104,0 161,0 18
43555 5 x 2 x 0,5 12,0 120,0 201,0 20 43540 4x2x1 14,8 186,0 360,0 18
43525 6 x 2 x 0,5 13,1 148,0 260,0 20 43561 5x2x1 16,6 231,0 412,0 18
43526 8 x 2 x 0,5 14,4 180,0 310,0 20 43541 6x2x1 18,4 260,0 472,0 18
43527 10 x 2 x 0,5 17,3 236,0 398,0 20 43542 8x2x1 20,1 322,0 540,0 18
43528 16 x 2 x 0,5 20,2 338,0 515,0 20 43543 10 x 2 x 1 23,9 382,0 670,0 18
43529 20 x 2 x 0,5 21,6 394,0 688,0 20 43544 16 x 2 x 1 27,8 578,0 982,0 18
43530 30 x 2 x 0,5 27,3 577,0 980,0 20 43545 20 x 2 x 1 30,3 710,0 1240,0 18
43531 40 x 2 x 0,5 28,9 684,0 1390,0 20 43546 30 x 2 x 1 36,0 1050,0 1720,0 18
43532 50 x 2 x 0,5 31,4 834,0 1860,0 20 43562 2 x 2 x 1,5 13,4 81,0 164,0 16
43556 2 x 2 x 0,75 10,1 61,0 117,0 19 43563 3 x 2 x 1,5 14,9 141,0 197,0 16
43557 3 x 2 x 0,75 11,3 97,0 142,0 19 43547 4 x 2 x 1,5 16,6 261,0 480,0 16
43533 4 x 2 x 0,75 12,2 141,0 240,0 19 43564 5 x 2 x 1,5 18,4 284,0 516,0 16
43558 5 x 2 x 0,75 13,6 163,0 304,0 19 43548 6 x 2 x 1,5 20,4 355,0 590,0 16
43534 6 x 2 x 0,75 15,1 198,0 352,0 19 43549 8 x 2 x 1,5 22,4 448,0 696,0 16
43535 8 x 2 x 0,75 16,6 246,0 415,0 19 43550 10 x 2 x 1,5 27,0 551,0 874,0 16
43536 10 x 2 x 0,75 19,7 305,0 505,0 19 43551 16 x 2 x 1,5 31,0 838,0 1340,0 16
43537 16 x 2 x 0,75 23,0 446,0 732,0 19 43552 20 x 2 x 1,5 32,1 1030,0 1620,0 16
43538 20 x 2 x 0,75 24,7 530,0 860,0 19
147
Data and Computer Cables
Application
The data transmission cables RD-Y(St)Y are used in measurement and control technology such as in control rooms of industrial plants and power
stations. The cables serves for transmission of analog and digital signals up to frequencies of approx. 10 kHz. These cables offer considerable advantages
by using the quick and economical connecting possibilities in Maxi-Termi-Point technique. This solderless connecting technique is defined by a
compression termination that employs a spring-clip for the connection of the cable to a square rigid post without pre-stripping. For this technique it
is necessary to have an exact 7-core stranded conductor and a Semi-Rigid-PVC. Suitable for fixed installation only inside of buildings. With blue outer
sheath suitable for intrinsic safe systems.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part No.pairs x Sheath No. Outer Cop. Weight AWG-No. Part No.pairs x Sheath No. Outer Cop. Weight AWG-No.
no. cross-sec. colour units approx. weight approx. no. cross-sec. colour units approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
20140 2 x 2 x 0,5 GY - 6,8 25,0 61,0 20 20189 2 x 2 x 0,5 BU - 6,8 25,0 61,0 20
20141 4 x 2 x 0,5 GY 1 8,7 45,0 96,0 20 20190 4 x 2 x 0,5 BU 1 8,7 45,0 96,0 20
20142 8 x 2 x 0,5 GY 2 11,0 85,0 160,0 20 20191 8 x 2 x 0,5 BU 2 11,0 85,0 160,0 20
20143 12 x 2 x 0,5 GY 3 12,5 125,0 210,0 20 20192 12 x 2 x 0,5 BU 3 12,5 125,0 210,0 20
20144 16 x 2 x 0,5 GY 4 14,0 165,0 282,0 20 20193 16 x 2 x 0,5 BU 4 14,0 165,0 282,0 20
20145 24 x 2 x 0,5 GY 6 17,0 245,0 330,0 20 20194 24 x 2 x 0,5 BU 6 17,0 245,0 330,0 20
20146 32 x 2 x 0,5 GY 8 20,0 325,0 530,0 20 20195 32 x 2 x 0,5 BU 8 20,0 325,0 530,0 20
20147 48 x 2 x 0,5 GY 12 23,5 485,0 730,0 20 20196 48 x 2 x 0,5 BU 12 23,5 485,0 730,0 20
20148 96 x 2 x 0,5 GY 24 32,5 965,0 1400,0 20 20197 96 x 2 x 0,5 BU 24 32,5 965,0 1400,0 20
148
Data and Computer Cables
Application
The data transmission cables RD-Y(St)Yv are used in measurement and control technology such as in control rooms of industrial plants and power
stations. The pairs are twisted with short pitches and different lay-lengths which lead to good crosstalk attenuation values in a unit. The cables serves
for transmission of analog and digital signals up to frequencies of approx. 10 kHz. These cables offer considerable advantages by using the quick and
economical connecting possibilities in Maxi-Termi-Point technique. This solderless connecting technique is defined by a compression termination
that employs a spring-clip for the connection of the cable to a square rigid post without pre-stripping. For this technique it is necessary to have an
exact 7-core stranded conductor and a Semi-Rigid-PVC. Suitable for fixed installation only inside of buildings. With the reinforced PVC(-Yv) outer
sheath these cables are suitable for fixed installation in inside buildings and also in open air and in underground.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
RD-Y(St)Yv RD-Y(St)YY
Part no. No.pairs x No. Outer Cop. Weight AWG-No. Part no. No.pairs x No. Outer Cop. Weight AWG-No.
cross-sec. units approx. weight approx. cross-sec. units approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
20160 2 x 2 x 0,5 - 8,5 25,0 80,0 20 20180 2 x 2 x 0,5 - 8,5 25,0 90,0 20
20161 4 x 2 x 0,5 1 10,0 45,0 125,0 20 20181 4 x 2 x 0,5 1 10,6 45,0 140,0 20
20162 8 x 2 x 0,5 2 13,0 85,0 200,0 20 20182 8 x 2 x 0,5 2 13,2 85,0 220,0 20
20163 12 x 2 x 0,5 3 14,0 125,0 255,0 20 20183 12 x 2 x 0,5 3 14,8 125,0 275,0 20
20164 16 x 2 x 0,5 4 15,5 165,0 315,0 20 20184 16 x 2 x 0,5 4 15,8 165,0 350,0 20
20165 24 x 2 x 0,5 6 18,5 245,0 370,0 20 20185 24 x 2 x 0,5 6 18,2 245,0 470,0 20
20166 32 x 2 x 0,5 8 20,5 325,0 555,0 20 20186 32 x 2 x 0,5 8 22,8 325,0 620,0 20
20167 48 x 2 x 0,5 12 24,0 485,0 1045,0 20 20187 48 x 2 x 0,5 12 24,0 485,0 850,0 20
20168 96 x 2 x 0,5 24 35,5 965,0 1300,0 20 20188 96 x 2 x 0,5 24 36,5 965,0 1450,0 20
149
Data and Computer Cables
Application
Instrumentation cables are used in data processing and process control. Instrumentation cables are suitable for fixed installations in damp locations,
in open spaces and for underground laying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Sheath Outer Cop. Weight AWG-No. Part no. No.pairs x Sheath Outer Cop. Weight AWG-No.
cross-sec. colour approx. weight approx. cross-sec. colour approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
20099 1 x 2 x 0,5 BK 7,5 15,0 74,0 20 20235 1 x 2 x 0,5 BU 7,5 15,0 74,0 20
20100 2 x 2 x 0,5 BK 9,8 30,0 117,0 20 20236 2 x 2 x 0,5 BU 9,8 30,0 117,0 20
20101 4 x 2 x 0,5 BK 11,3 50,0 140,0 20 20237 4 x 2 x 0,5 BU 11,3 50,0 140,0 20
20233 6 x 2 x 0,5 BK 13,1 70,0 190,0 20 20238 6 x 2 x 0,5 BU 13,1 70,0 190,0 20
20102 8 x 2 x 0,5 BK 14,6 90,0 215,0 20 20239 8 x 2 x 0,5 BU 14,6 90,0 215,0 20
20103 10 x 2 x 0,5 BK 16,1 110,0 220,0 20 20240 10 x 2 x 0,5 BU 16,1 110,0 220,0 20
20104 12 x 2 x 0,5 BK 16,4 130,0 280,0 20 20241 12 x 2 x 0,5 BU 16,4 130,0 280,0 20
20105 16 x 2 x 0,5 BK 18,3 170,0 352,0 20 20242 16 x 2 x 0,5 BU 18,3 170,0 352,0 20
20106 20 x 2 x 0,5 BK 19,2 210,0 385,0 20 20243 20 x 2 x 0,5 BU 19,2 210,0 385,0 20
20107 24 x 2 x 0,5 BK 22,3 250,0 468,0 20 20244 24 x 2 x 0,5 BU 22,3 250,0 468,0 20
20108 36 x 2 x 0,5 BK 24,5 370,0 656,0 20 20245 36 x 2 x 0,5 BU 24,5 370,0 656,0 20
20109 48 x 2 x 0,5 BK 27,7 490,0 854,0 20 20246 48 x 2 x 0,5 BU 27,7 490,0 854,0 20
20149 1 x 2 x 0,75 BK 7,9 20,0 74,0 19 20169 1 x 2 x 0,75 BU 7,9 20,0 74,0 19
20150 2 x 2 x 0,75 BK 10,4 35,0 123,0 19 20170 2 x 2 x 0,75 BU 10,4 35,0 123,0 19
20151 4 x 2 x 0,75 BK 11,9 65,0 164,0 19 20171 4 x 2 x 0,75 BU 11,9 65,0 164,0 19
20152 8 x 2 x 0,75 BK 15,0 125,0 258,0 19 20172 8 x 2 x 0,75 BU 15,0 125,0 258,0 19
20153 10 x 2 x 0,75 BK 17,0 154,0 305,0 19 20173 10 x 2 x 0,75 BU 17,0 154,0 305,0 19
20154 12 x 2 x 0,75 BK 17,6 185,0 350,0 19 20174 12 x 2 x 0,75 BU 17,6 185,0 350,0 19
20155 16 x 2 x 0,75 BK 19,5 245,0 445,0 19 20175 16 x 2 x 0,75 BU 19,5 245,0 445,0 19
20156 20 x 2 x 0,75 BK 21,5 298,0 520,0 19 20176 20 x 2 x 0,75 BU 21,5 298,0 520,0 19
20157 24 x 2 x 0,75 BK 24,0 365,0 620,0 19 20177 24 x 2 x 0,75 BU 24,0 365,0 620,0 19
20158 36 x 2 x 0,75 BK 26,5 532,0 940,0 19 20178 36 x 2 x 0,75 BU 26,5 532,0 940,0 19
20159 48 x 2 x 0,75 BK 30,3 708,0 1250,0 19 20179 48 x 2 x 0,75 BU 30,3 708,0 1250,0 19
20125 1 x 2 x 1,3 BK 8,7 31,0 102,0 - 20247 1 x 2 x 1,3 BU 8,7 31,0 102,0 -
20132 1 x 3 x 1,3 BK 9,0 44,0 116,0 - 20255 1 x 3 x 1,3 BU 9,0 44,0 116,0 -
20126 2 x 2 x 1,3 BK 11,5 62,0 161,0 - 20248 2 x 2 x 1,3 BU 11,5 62,0 161,0 -
20127 4 x 2 x 1,3 BK 14,3 114,0 230,0 - 20249 4 x 2 x 1,3 BU 14,3 114,0 230,0 -
20234 6 x 2 x 1,3 BK 16,0 168,0 310,0 - 20250 6 x 2 x 1,3 BU 15,8 168,0 310,0 -
20128 8 x 2 x 1,3 BK 17,3 218,0 377,0 - 20251 8 x 2 x 1,3 BU 17,3 218,0 377,0 -
20129 12 x 2 x 1,3 BK 20,5 322,0 515,0 - 20252 12 x 2 x 1,3 BU 20,5 322,0 515,0 -
20130 16 x 2 x 1,3 BK 23,0 426,0 656,0 - 20253 16 x 2 x 1,3 BU 23,0 426,0 656,0 -
20131 24 x 2 x 1,3 BK 27,9 684,0 952,0 - 20254 24 x 2 x 1,3 BU 27,9 684,0 952,0 -
150
Data and Computer Cables
Application
Instrumentation cables are used in data processing and process control. The individual screening of the pairs guarantee high cross-talk attenuation.
The electrostatic screen protect the screened pairs against outer electrostatic interference fields. Low level of line attenuations and low mutual
capacitances enable long transmission distances and fast pulse acceleration. Instrumentation cables are suitable for fixed installations in damp locations,
in open spaces and for underground laying.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Sheath Outer Cop. Weight AWG-No. Part no. No.pairs x Sheath Outer Cop. Weight AWG-No.
cross-sec. colour approx. weight approx. cross-sec. colour approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
20115 2 x 2 x 0,5 BK 11,0 35,0 128,0 20 21537 2 x 2 x 0,5 BU 11,0 35,0 128,0 20
20116 4 x 2 x 0,5 BK 12,6 60,0 170,0 20 21538 4 x 2 x 0,5 BU 12,6 60,0 170,0 20
21535 6 x 2 x 0,5 BK 14,6 82,0 215,0 20 21539 6 x 2 x 0,5 BU 14,6 82,0 215,0 20
20117 8 x 2 x 0,5 BK 15,5 121,0 246,0 20 21540 8 x 2 x 0,5 BU 15,5 121,0 246,0 20
20118 10 x 2 x 0,5 BK 16,8 136,0 261,0 20 21541 10 x 2 x 0,5 BU 16,8 136,0 261,0 20
20119 12 x 2 x 0,5 BK 17,9 161,0 351,0 20 21542 12 x 2 x 0,5 BU 17,9 161,0 351,0 20
20120 16 x 2 x 0,5 BK 19,8 212,0 430,0 20 21543 16 x 2 x 0,5 BU 19,8 212,0 430,0 20
20121 20 x 2 x 0,5 BK 21,0 262,0 496,0 20 21544 20 x 2 x 0,5 BU 21,0 262,0 496,0 20
20122 24 x 2 x 0,5 BK 23,4 313,0 604,0 20 21545 24 x 2 x 0,5 BU 23,4 313,0 604,0 20
20123 36 x 2 x 0,5 BK 26,5 465,0 850,0 20 21546 36 x 2 x 0,5 BU 26,5 465,0 850,0 20
20124 48 x 2 x 0,5 BK 29,5 616,0 1115,0 20 21547 48 x 2 x 0,5 BU 29,5 616,0 1115,0 20
20133 2 x 2 x 1,3 BK 12,8 68,0 184,0 - 21548 2 x 2 x 1,3 BU 12,8 68,0 184,0 -
20134 4 x 2 x 1,3 BK 14,8 124,0 269,0 - 21549 4 x 2 x 1,3 BU 14,8 124,0 269,0 -
21536 6 x 2 x 1,3 BK 17,3 178,0 370,0 - 21550 6 x 2 x 1,3 BU 17,3 178,0 370,0 -
20135 8 x 2 x 1,3 BK 18,5 239,0 442,0 - 21551 8 x 2 x 1,3 BU 18,5 239,0 442,0 -
20136 12 x 2 x 1,3 BK 21,6 353,0 593,0 - 21552 12 x 2 x 1,3 BU 21,6 353,0 593,0 -
20137 16 x 2 x 1,3 BK 24,7 468,0 789,0 - 21553 16 x 2 x 1,3 BU 24,7 468,0 789,0 -
20138 24 x 2 x 1,3 BK 29,8 697,0 1104,0 - 21554 24 x 2 x 1,3 BU 29,8 697,0 1104,0 -
151
Data and Computer Cables
Application
These cable types are suitable for transmission of signals and measurements in the symmetric circuits of the control and regulation technology, and
for the transmission of data and process information in computer systems. Used in dry and damp premises, and in or under plaster in the open air for
fixed installation. Installation cables are not allowed for purposes of high current and power or burial installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Sheath Outer Cop. Weight Part no. No.pairs x Sheath Outer Cop. Weight
cross-sec. colour approx. weight approx. cross-sec. colour approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
48500 1 x 2 x 0,8 GY 5,0 20,0 43,0 - 48519 1 x 2 x 0,8 BU 5,0 20,0 43,0 -
48501 2 x 2 x 0,8 GY 6,6 25,0 60,0 - 48520 2 x 2 x 0,8 BU 6,6 25,0 60,0 -
48502 4 x 2 x 0,8 GY 8,3 45,0 95,0 - 48521 4 x 2 x 0,8 BU 8,3 45,0 95,0 -
48503 8 x 2 x 0,8 GY 10,5 85,0 157,0 - 48522 8 x 2 x 0,8 BU 10,5 85,0 157,0 -
48504 12 x 2 x 0,8 GY 11,8 126,0 224,0 - 48523 12 x 2 x 0,8 BU 11,8 126,0 224,0 -
48505 16 x 2 x 0,8 GY 13,5 166,0 290,0 - 48524 16 x 2 x 0,8 BU 13,5 166,0 290,0 -
48506 20 x 2 x 0,8 GY 14,7 206,0 350,0 - 48525 20 x 2 x 0,8 BU 14,7 206,0 350,0 -
48507 32 x 2 x 0,8 GY 19,0 327,0 545,0 - 48526 32 x 2 x 0,8 BU 19,0 327,0 545,0 -
48508 40 x 2 x 0,8 GY 20,7 407,0 660,0 - 48527 40 x 2 x 0,8 BU 20,7 407,0 660,0 -
48509 80 x 2 x 0,8 GY 29,5 809,0 1160,0 - 48528 80 x 2 x 0,8 BU 29,5 809,0 1160,0 -
152
Data and Computer Cables
Application
These cable types are suitable for transmission of signals and measurements in the symmetric circuits of the control and regulation technology, and
for the transmission of data and process information in computer systems. Used in dry and damp premises, and in or under plaster in the open air for
fixed installation. Installation cables are not allowed for purposes of high current and power or burial installation.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Sheath Outer Cop. Weight AWG-No. Part no. No.pairs x Sheath Outer Cop. Weight AWG-No.
cross-sec. colour approx. weight approx. cross-sec. colour approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
48510 2 x 2 x 0,5 GY 7,0 51,0 94,0 20 48529 2 x 2 x 0,5 BU 7,0 51,0 94,0 20
48511 4 x 2 x 0,5 GY 8,6 87,0 154,0 20 48530 4 x 2 x 0,5 BU 8,6 87,0 154,0 20
48512 8 x 2 x 0,5 GY 12,0 144,0 259,0 20 48531 8 x 2 x 0,5 BU 12,0 144,0 259,0 20
48513 12 x 2 x 0,5 GY 13,1 196,0 340,0 20 48532 12 x 2 x 0,5 BU 13,1 196,0 340,0 20
48514 16 x 2 x 0,5 GY 14,3 249,0 431,0 20 48533 16 x 2 x 0,5 BU 14,3 249,0 431,0 20
48515 20 x 2 x 0,5 GY 15,5 299,0 494,0 20 48534 20 x 2 x 0,5 BU 15,5 299,0 494,0 20
48516 24 x 2 x 0,5 GY 19,4 348,0 604,0 20 48535 24 x 2 x 0,5 BU 19,4 348,0 604,0 20
48517 32 x 2 x 0,5 GY 20,5 444,0 737,0 20 48536 32 x 2 x 0,5 BU 20,5 444,0 737,0 20
48518 40 x 2 x 0,5 GY 22,5 537,0 844,0 20 48537 40 x 2 x 0,5 BU 22,5 537,0 844,0 20
153
Data and Computer Cables
Application
Halogen-free installation cables with improved characteristics in the case of fire are used for telephone transmission, measuring and signal purposes.
The copper screened design (C) protects the transmission circuits against electrical interferences. A fire propagation is prevented through high oxygen
index of the insulation material and produce no corrosive gases in case of fire. They are preferably used for telecommunication installations inside
buildings. These cables are suitable for fixed installation in areas with danger of fire, in dry and damp environments as well as in and under plaster.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part No.pairs x Core No. Outer Cop. Weight AWG-No. Part No.pairs x Core No. Outer Cop. Weight AWG-No.
no. cross-sec. approx. units approx. weight approx. no. cross-sec. approx. units approx. weight approx.
mm mm mm kg / km kg / km mm mm mm kg / km kg / km
34350 2 x 2 x 0,5 1,6 - 6,8 44,0 102,0 20 34354 20 x 2 x 0,5 1,6 5 16,4 288,0 555,0 20
34351 4 x 2 x 0,5 1,6 1 9,1 80,0 168,0 20 34355 32 x 2 x 0,5 1,6 8 19,6 439,0 852,0 20
34352 8 x 2 x 0,5 1,6 2 11,4 152,0 297,0 20 34356 40 x 2 x 0,5 1,6 10 21,7 531,0 1005,0 20
34353 12 x 2 x 0,5 1,6 3 13,3 192,0 357,0 20
154
Data and Computer Cables
Application
The halogen-free data transmission cable RD-H(St)H are used for measurement and control technology for transmission of analog and digital signals
up to frequencies of approx. 10 kHz. The twisted pairs with short pitches (<50 mm for 0,5 mm) and different lay-lengths which lead good cross-talk
attenuation values in a unit. These cables are used in inside buildings (in special cases in open air, but with sufficient protection against sunlight is
necessary).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
20200 2 x 2 x 0,5 7,0 26,0 70,0 20 20216 2x2x1 9,0 47,0 110,0 18
20201 4 x 2 x 0,5 9,0 46,0 110,0 20 20217 4x2x1 12,0 89,0 190,0 18
20202 8 x 2 x 0,5 11,6 86,0 190,0 20 20218 8x2x1 16,5 172,0 320,0 18
20203 12 x 2 x 0,5 13,5 127,0 240,0 20 20219 12 x 2 x 1 17,5 255,0 435,0 18
20204 16 x 2 x 0,5 14,0 167,0 300,0 20 20220 16 x 2 x 1 19,5 338,0 560,0 18
20205 20 x 2 x 0,5 16,0 209,0 360,0 20 20221 20 x 2 x 1 21,0 423,0 680,0 18
20206 24 x 2 x 0,5 17,5 250,0 420,0 20 20222 24 x 2 x 1 23,0 507,0 800,0 18
20207 28 x 2 x 0,5 19,0 290,0 480,0 20 20223 28 x 2 x 1 27,0 590,0 905,0 18
20208 32 x 2 x 0,5 21,0 331,0 570,0 20 20225 32 x 2 x 1 29,0 674,0 1080,0 18
20209 36 x 2 x 0,5 21,5 372,0 614,0 20 20226 36 x 2 x 1 30,0 757,0 1260,0 18
20210 40 x 2 x 0,5 22,5 412,0 680,0 20 20227 40 x 2 x 1 31,0 841,0 1330,0 18
20211 44 x 2 x 0,5 23,5 453,0 700,0 20 20228 44 x 2 x 1 34,0 924,0 1410,0 18
20212 48 x 2 x 0,5 24,0 494,0 790,0 20 20229 48 x 2 x 1 32,5 1008,0 1550,0 18
20213 64 x 2 x 0,5 30,0 658,0 1040,0 20 20230 64 x 2 x 1 39,0 1342,0 2000,0 18
20214 80 x 2 x 0,5 33,0 821,0 1300,0 20 20231 80 x 2 x 1 43,0 1676,0 2470,0 18
20215 96 x 2 x 0,5 36,0 986,0 1510,0 20 20232 96 x 2 x 1 47,0 2016,0 2970,0 18
155
DRAG CHAIN CABLES
3
in
E
VD eld 29
ng
x
xe
ex
VD
ed
U
R/ shi E 0
xi
- fi
- fl
./
0 /
le
fix
ed
no
H A ed / VD
-f
U
C)
C)
-
ge
us
us
CS REG
e n es /
(
(
C
e
lta
di
di
se
re
re
t
V- -fre
ut tan
r
n
ra
ra
co
tu
tu
u
vo
E
ai
or
ra
ra
sis
n
g
A
d
ch
al
ge
in
in
pe
pe
re
do
re
in
ge
nd
nd
ag
lo
lo
re
m
L/
om
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
N
PVC drag chain cables
MULTISPEED 500-TPE
-30 to +80 -40 to +80 300/500 5x 3x X X X X 177
BIOFLEX-500 -JZ-HF-C
-20 to +80 -40 to +80 300/500 15x 4x X X X 182
SUPERTRONIC -PUR
-5 to +70 -40 to +70 350 5x 3x X X X X 189
SUPER-PAAR-TRONIC-C-PUR
-30 to +70 -40 to +70 350 10x 5x X X X X X X 191
157
SELECTION TABLE - DRAG CHAIN CABLES
ng
in
xi
g
/s 2
ce
fle
in
/
an
ex
ge U
(m
-
es ist
lta 0 /
- fl
us
)
-c t d
vo U
/s
di
io
)
C)
g ge
en
(m
ra
at
or
(
tin lta
er
m
re
in
s
25
e
el
nt
ra vo
ee
le
ui CSA
ov
nd
tu
s
c
yc
)
al
to
le
sp
ac
pe l
ra
ia
m
O ina
be
ov
r
.c
up
va
te
eq L/
er
pe
.
ge
.
ax
ax
ou
pr
ax
ax
m
om
.
at
in
U
m
=
Ap
M
M
0
Pa
M
M
M
M
(D
(1
Te
N
PVC drag chain cables
JZ-HF 10 7.5 x D 2 10 9 Mio PVC/PVC 300/500V -10 to +80 VDE 160 423
JZ-HF CY 10 10 x D 2 10 9 Mio PVC/CU/PVC 300/500V -10 to +80 VDE 163 427
MULTISPEED 500-PVC 100 7.5 x D 5 50 9 Mio PP/PVC 300/500V -15 to +80 162 425
MULTISPEED 500-C-PVC 100 7.5 x D 5 50 9 Mio PP/CU/PVC 300/500V -15 to +80 165 429
PUR & TPE drag chain cables
PUR-JZ-HF 15 7.5 x D 3 10 10 Mio PVC/PUR 300/500V -20 to +80 167 430
PUR-JZ-HF-YCP 15 10 x D 3 10 10 Mio PVC/CU/PUR 300/500V -20 to +80 172 436
MULTIFLEX 512-PUR 100 5xD 4 10 11 Mio PP/PUR 300/500V -30 to +80 169 431
MULTIFLEX 512-C-PUR 100 7.5 x D 4 10 11 Mio PP/CU/PUR 300/500V -30 to +80 174 437
MULTISPEED 500-PUR
450 7.5 x D 5 50 11 Mio PP/PUR 300/500V -30 to +80 171 433
MULTISPEED 500-C-PUR 450 7.5 x D 5 50 11 Mio PP/CU/PUR 300/500V -30 to +80 176 439
MULTISPEED 500-TPE 450 5xD 5 50 11 Mio PP/TPE 300/500V -30 to +80 177 441
MULTISPEED 500-C-TPE
450 5xD 5 50 11 Mio PP/CU/TPE 300/500V -30 to +80 179 443
Bio-oil resistant and microbe-resistant drag chain cables
BIOFLEX 500 JZ-HF 100 10 x D 4 10 11 Mio Poly/Poly 300/500V -20 to +80 181 -
BIOFLEX 500 JZ-HF-C
100 15 x D 4 10 11 Mio Poly/CU/Poly 300/500V -20 to +80 182 -
KOMPOSPEED JZ-HF-500 100 7.5 x D 4 10 10 Mio Poly/Poly 300/500V -30 to +90 184 -
KOMPOSPEED JZ-HF-500-C 100 7.5 x D 4 10 10 Mio Poly/CU/Poly 300/500V -30 to +90 185 -
Sensor cables
SUPERTRONIC-PVC 5 5xD 2 10 9 Mio PVC/PVC 350V -5 to +70 187 445
SUPERTRONIC -C-PVC
5 7.5 x D 2 10 9 Mio PVC/CU/PVC 350V -5 to +70 188 446
SUPERTRONIC-PUR 5 5xD 3 10 9 Mio PVC/PUR 350V -5 to +70 189 447
SUPERTRONIC-C-PUR 15 7.5 x D 4 10 9 Mio PP/CU/PUR 350V -30 to +70 190 449
SUPER-PAAR-TRONIC-C-PUR 30 10 x D 4 50 9 Mio PP/CU/PUR 350V -30 to +70 191 451
SENSORFLEX-H (Li12Y11Y) 30 5xD 5 10 11 Mio TPE/PUR 350V -30 to +80 192 -
SENSORFLEX-H (Li9Y11Y) 30 7.5 x D 5 10 11 Mio PP/PUR 350V -30 to +80 192 -
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).
158
PVC DRAG CHAIN CABLES
Cables for Drag Chains / PVC Cables for Drag Chains
JZ-HF flexible, number coded, control cable for drag chains, oil resistant,
meter marking
Application
JZ-HF cables are ideal for use in the machine tool industry, in robotics and machine production and anywhere where high flexibility is essential. These
cables have shown excellent performance in combination with standard cable trays. These cables are suitable for flexible use for medium mechanical
stresses with free movements. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors
with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation
in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15001 2 x 0,5 5,0 9,6 46,0 20 15019 2 x 0,75 5,4 14,4 58,0 19
15002 3 G 0,5 5,3 14,0 57,0 20 15020 3 G 0,75 5,7 22,0 73,0 19
15003 4 G 0,5 5,7 19,0 70,0 20 15021 4 G 0,75 6,4 29,0 77,0 19
15004 5 G 0,5 6,4 24,0 93,0 20 15022 5 G 0,75 7,0 36,0 119,0 19
15005 7 G 0,5 7,5 34,0 127,0 20 15023 7 G 0,75 8,3 50,0 165,0 19
15090 7 x 0,5 7,5 34,0 127,0 20 15024 10 G 0,75 10,1 72,0 216,0 19
15006 10 G 0,5 9,1 48,0 161,0 20 15025 12 G 0,75 10,2 86,0 247,0 19
15007 12 G 0,5 9,2 58,0 177,0 20 15026 14 G 0,75 10,9 101,0 284,0 19
15008 14 G 0,5 9,8 67,0 213,0 20 15027 16 G 0,75 11,5 115,0 320,0 19
15009 16 G 0,5 10,3 77,0 260,0 20 15028 18 G 0,75 12,1 130,0 356,0 19
15010 18 G 0,5 11,1 86,0 284,0 20 15029 20 G 0,75 12,8 144,0 453,0 19
15011 20 G 0,5 11,6 96,0 318,0 20 15030 25 G 0,75 14,9 180,0 498,0 19
15012 25 G 0,5 13,4 120,0 363,0 20 15031 30 G 0,75 15,2 216,0 510,0 19
15013 30 G 0,5 13,7 144,0 432,0 20 15032 34 G 0,75 16,6 245,0 550,0 19
15014 34 G 0,5 15,0 163,0 487,0 20 15033 36 G 0,75 16,6 259,0 570,0 19
15015 36 G 0,5 15,0 173,0 518,0 20 15034 42 G 0,75 18,1 302,0 600,0 19
15016 42 G 0,5 16,1 202,0 575,0 20 15035 50 G 0,75 20,0 360,0 700,0 19
15017 50 G 0,5 17,9 240,0 675,0 20 15036 61 G 0,75 22,1 432,0 820,0 19
15018 61 G 0,5 19,6 290,0 829,0 20 15091 65 G 0,75 22,7 439,0 841,0 19
Continuation
160
Cables for Drag Chains / PVC Cables for Drag Chains
JZ-HF flexible, number coded, control cable for drag chains, oil resistant,
meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15037 2x1 5,7 19,0 65,0 18 15073 2 x 2,5 7,7 48,0 130,0 14
15038 3G1 6,0 29,0 84,0 18 15074 3 G 2,5 8,4 72,0 160,0 14
15039 4G1 6,8 38,0 113,0 18 15075 4 G 2,5 9,1 96,0 200,0 14
15040 5G1 7,4 48,0 137,0 18 15076 5 G 2,5 10,2 120,0 268,0 14
15041
15042
15043
7G1
10 G 1
12 G 1
8,8
10,7
10,8
67,0
96,0
115,0
192,0
251,0
295,0
18
18
18
15077
15078
15079
7 G 2,5
10 G 2,5
12 G 2,5
12,2
15,0
15,2
168,0
240,0
288,0
357,0
486,0
572,0
14
14
14
C
15044 14 G 1 11,6 134,0 337,0 18 15080 14 G 2,5 16,1 336,0 612,0 14
15045 16 G 1 12,2 154,0 379,0 18 15081 16 G 2,5 17,2 384,0 702,0 14
15046 18 G 1 13,0 173,0 420,0 18 15082 18 G 2,5 18,1 432,0 800,0 14
15047 20 G 1 13,6 192,0 480,0 18 15083 20 G 2,5 19,2 480,0 920,0 14
15048 25 G 1 15,8 240,0 600,0 18 15084 25 G 2,5 22,5 600,0 1100,0 14
15049 30 G 1 16,4 288,0 695,0 18 15085 30 G 2,5 23,5 720,0 1400,0 14
15050 34 G 1 17,8 326,0 777,0 18 15086 34 G 2,5 25,2 816,0 1500,0 14
15051 36 G 1 17,8 346,0 825,0 18 15087 36 G 2,5 25,2 864,0 1600,0 14
15052 41 G 1 19,3 403,0 926,0 18 15088 42 G 2,5 27,4 1008,0 1800,0 14
15214 42 G 1 19,3 403,0 948,0 18 15089 50 G 2,5 30,0 1200,0 2100,0 14
15053 50 G 1 21,2 480,0 1092,0 18 15142 3G4 10,4 115,0 221,0 12
15092 61 G 1 23,7 586,0 1204,0 18 15143 4G4 11,4 154,0 260,0 12
15054 65 G 1 24,4 624,0 1400,0 18 15144 5G4 12,7 192,0 318,0 12
15055 2 x 1,5 6,4 29,0 91,0 16 15145 4G6 13,3 230,0 392,0 10
15056 3 G 1,5 6,8 43,0 117,0 16 15146 5G6 14,5 288,0 481,0 10
15057 4 G 1,5 7,4 58,0 147,0 16 15147 4 G 10 17,7 384,0 642,0 8
15058 5 G 1,5 8,3 72,0 181,0 16 15148 5 G 10 19,7 480,0 780,0 8
15059 7 G 1,5 9,9 101,0 273,0 16 15149 4 G 16 20,8 614,0 926,0 6
15060 10 G 1,5 11,9 144,0 344,0 16 15150 5 G 16 23,3 768,0 1135,0 6
15061 12 G 1,5 12,1 173,0 391,0 16
15062 14 G 1,5 12,9 202,0 457,0 16
15063 16 G 1,5 13,6 230,0 523,0 16
15064 18 G 1,5 14,5 259,0 590,0 16
15065 20 G 1,5 15,2 288,0 650,0 16
15066 25 G 1,5 17,8 360,0 801,0 16
15067 30 G 1,5 18,2 432,0 958,0 16
15068 34 G 1,5 19,7 490,0 1084,0 16
15069 36 G 1,5 19,7 518,0 1135,0 16
15070 42 G 1,5 21,5 605,0 1290,0 16
15071 50 G 1,5 23,7 720,0 1521,0 16
15072 60 G 1,5 25,3 864,0 1885,0 16
15215 61 G 1,5 26,2 878,0 1916,0 16
15216 65 G 1,5 27,2 936,0 1994,0 16
161
Cables for Drag Chains / PVC Cables for Drag Chains
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED 500-C-PVC,
confer page 165
Application
HELUKABEL MULTISPEED 500-PVC are installed there, where the extreme requirements for the cables are necessary. The selected materials and
lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and low speed of movements.
These high flexible PVC control cables are suitable for shift- and bending stresses in machines and machine tool constructions. These are installed in
dry, moist rooms and in open air with free movement without tensile stress or forced movements. For applications which go beyond standard solutions
(for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for
drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24050 2 x 0,5 4,3 9,6 40,0 20 24068 5G1 6,7 48,0 101,0 18
24051 3 G 0,5 4,6 14,4 45,0 20 24069 7G1 11,1 67,0 140,0 18
24052 4 G 0,5 5,0 19,0 57,0 20 24070 12 G 1 12,0 115,0 227,0 18
24053 5 G 0,5 5,4 24,0 66,0 20 24071 18 G 1 14,8 173,0 351,0 18
24054 7 G 0,5 8,9 33,6 81,0 20 24072 25 G 1 17,2 240,0 489,0 18
24055 12 G 0,5 9,7 58,0 133,0 20 24073 3 G 1,5 6,4 43,0 88,0 16
24056 18 G 0,5 11,8 86,0 194,0 20 24074 4 G 1,5 7,0 58,0 110,0 16
24057 25 G 0,5 13,9 120,0 274,0 20 24075 5 G 1,5 7,8 72,0 130,0 16
24058 4 G 0,75 5,6 29,0 63,0 19 24076 7 G 1,5 13,0 101,0 182,0 16
24059 5 G 0,75 6,3 36,0 79,0 19 24077 12 G 1,5 14,2 173,0 319,0 16
24060 7 G 0,75 10,3 50,0 107,0 19 24078 18 G 1,5 17,5 259,0 420,0 16
24061 12 G 0,75 11,0 86,0 169,0 19 24079 25 G 1,5 20,1 360,0 604,0 16
24062 18 G 0,75 13,9 130,0 247,0 19 24080 4 G 2,5 8,8 96,0 172,0 14
24063 25 G 0,75 15,9 180,0 366,0 19 24081 5 G 2,5 9,8 120,0 219,0 14
24064 36 G 0,75 19,6 259,0 540,0 19 24082 7 G 2,5 16,1 168,0 303,0 14
24065 42 G 0,75 21,5 302,0 630,0 19 24083 12 G 2,5 17,8 288,0 504,0 14
24066 3G1 5,4 29,0 69,0 18 24084 18 G 2,5 21,8 432,0 754,0 14
24067 4G1 5,9 38,4 86,0 18 24085 25 G 2,5 24,4 600,0 940,0 14
162
Cables for Drag Chains / PVC Cables for Drag Chains
Application
JZ-HF cables are ideal for use in the machine tool industry, in robotics and machine production and anywhere where high flexibility is essential. These
cables have shown excellent performance in combination with standard cable trays. These cables are suitable for flexible use for medium mechanical
stresses with free movements. The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control
cable for the above application. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors
with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation
in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15930 2 x 0,5 7,2 30,0 90,0 20 15945 2 x 0,75 7,6 39,0 105,0 19
15931 3 G 0,5 7,5 38,0 115,0 20 15946 3 G 0,75 8,1 49,0 128,0 19
15932 4 G 0,5 8,1 48,0 140,0 20 15947 4 G 0,75 8,6 60,0 184,0 19
15933 5 G 0,5 8,6 64,0 168,0 20 15948 5 G 0,75 9,4 70,0 200,0 19
15934 7 G 0,5 9,9 70,0 217,0 20 15949 7 G 0,75 10,5 95,0 269,0 19
15935 12 G 0,5 11,6 100,0 274,0 20 15885 10 G 0,75 12,6 110,0 327,0 19
15876 14 G 0,5 12,2 135,0 332,0 20 15950 12 G 0,75 12,9 140,0 366,0 19
15877 16 G 0,5 13,0 145,0 388,0 20 15886 14 G 0,75 13,4 163,0 426,0 19
15936 18 G 0,5 13,8 154,0 445,0 20 15887 16 G 0,75 14,2 187,0 487,0 19
15937 20 G 0,5 14,3 160,0 497,0 20 15951 18 G 0,75 14,8 211,0 547,0 19
15878 21 G 0,5 14,8 175,0 500,0 20 15888 20 G 0,75 15,5 216,0 551,0 19
15938 25 G 0,5 16,1 240,0 505,0 20 15889 21 G 0,75 16,2 272,0 590,0 19
15879 30 G 0,5 16,6 280,0 515,0 20 15952 25 G 0,75 17,7 322,0 600,0 19
15880 34 G 0,5 17,7 290,0 530,0 20 15890 30 G 0,75 18,2 414,0 650,0 19
15881 36 G 0,5 17,7 300,0 572,0 20 15891 34 G 0,75 19,8 473,0 685,0 19
15882 42 G 0,5 19,2 330,0 605,0 20 15892 36 G 0,75 19,8 500,0 720,0 19
15883 50 G 0,5 21,2 393,0 742,0 20 15893 42 G 0,75 21,0 583,0 800,0 19
15894 50 G 0,75 23,1 695,0 954,0 19
Continuation
163
Cables for Drag Chains / PVC Cables for Drag Chains
164
Cables for Drag Chains / PVC Cables for Drag Chains
Application
HELUKABEL MULTISPEED 500-C-PVC are installed there, where the extreme requirements for the cables are necessary. The selected materials and
lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and low speed of movements.
These high flexible PVC control cables are suitable for shift- and bending stresses in machines and machine tool constructions. These are installed in
dry, moist rooms and in open air with free movement without tensile stress or forced movements. These screened cables are particularly suitable for
the interference-free transmission in instrumentation and control engineering applications. For applications which go beyond standard solutions (for
example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for
drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24086 2 x 0,5 6,2 30,0 88,0 20 24103 3G1 7,6 59,0 131,0 18
24087 3 G 0,5 6,7 36,0 101,0 20 24104 4G1 8,1 70,0 164,0 18
24088 4 G 0,5 7,2 42,0 116,0 20 24105 5G1 8,9 84,0 198,0 18
24089 5 G 0,5 7,6 48,0 146,0 20 24106 7G1 13,6 106,0 252,0 18
24090 7 G 0,5 11,4 64,0 181,0 20 24107 12 G 1 14,6 174,0 410,0 18
24091 9 G 0,5 11,4 80,0 219,0 20 24108 18 G 1 18,4 240,0 550,0 18
24092 12 G 0,5 12,4 105,0 271,0 20 24109 25 G 1 21,0 332,0 756,0 17
24093 18 G 0,5 14,7 137,0 374,0 20 24110 3 G 1,5 8,4 75,0 166,0 16
24094 25 G 0,5 17,1 210,0 542,0 20 24111 4 G 1,5 9,1 90,0 199,0 16
24095 2 x 0,75 6,8 40,0 96,0 19 24112 5 G 1,5 10,2 108,0 229,0 16
24096 3 G 0,75 7,3 48,0 111,0 19 24113 7 G 1,5 15,7 157,0 304,0 16
24097 4 G 0,75 7,8 55,0 140,0 19 24114 12 G 1,5 17,4 240,0 502,0 16
24098 5 G 0,75 8,3 66,0 161,0 19 24115 18 G 1,5 21,3 355,0 709,0 16
24099 7 G 0,75 12,7 85,0 227,0 19 24116 25 G 1,5 24,3 448,0 939,0 16
24100 12 G 0,75 13,7 135,0 317,0 19 24117 4 G 2,5 11,2 134,0 270,0 14
24101 18 G 0,75 17,1 190,0 486,0 19 24118 5 G 2,5 12,2 175,0 335,0 14
24102 25 G 0,75 19,5 275,0 651,0 19
165
PUR DRAG CHAIN CABLES
Cables for Drag Chains / PUR Cables for Drag Chains
PUR-JZ-HF high flexible, cable for drag chains, abrasion and coolant resistant,
meter marking
Application
PUR-JZ-HF is an extremely robust cable noted for its good tear and abrasion resistance. Due to its good performance with mineral oils and especially
in connection with coolants, this cable is well suited for use in the machinery, tool making and steel industries in critical areas. Its high abrasion resistance
and good flexing ability make it quick and easy to install and, with its low bending radius, ideal for use with cable trays. For applications which go
beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend
for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15520 2 x 0,5 5,5 9,6 45,0 20 15556 2x1 6,3 19,2 64,0 18
15521 3 G 0,5 6,0 14,4 56,0 20 15557 3G1 6,6 29,0 83,0 18
15522 4 G 0,5 6,4 19,1 69,0 20 15558 4G1 7,1 38,5 113,0 18
15523 5 G 0,5 6,9 24,0 92,0 20 15559 5G1 7,8 48,0 137,0 18
15524 7 G 0,5 7,9 33,6 126,0 20 15560 7G1 9,0 67,0 191,0 18
16161 7 x 0,5 7,8 33,6 126,0 20 15561 8G1 9,9 77,0 218,0 18
15525 8 G 0,5 8,6 38,0 136,0 20 15562 10 G 1 11,1 96,0 251,0 18
15526 10 G 0,5 9,7 48,0 158,0 20 15563 12 G 1 11,1 115,0 294,0 18
15527 12 G 0,5 9,9 58,0 176,0 20 15564 14 G 1 12,1 134,0 337,0 18
15528 14 G 0,5 10,4 67,0 212,0 20 15565 18 G 1 13,6 173,0 420,0 18
15529 18 G 0,5 11,4 86,4 283,0 20 15566 21 G 1 14,2 196,0 504,0 18
15530 21 G 0,5 12,1 96,0 310,0 20 15567 25 G 1 16,1 240,0 600,0 18
15531 25 G 0,5 13,5 120,0 330,0 20 15568 32 G 1 17,6 308,0 732,0 18
15532 30 G 0,5 14,2 144,0 390,0 20 15569 34 G 1 18,4 326,0 776,0 18
15533 34 G 0,5 15,2 163,0 420,0 20 15570 41 G 1 19,7 394,0 925,0 18
15534 42 G 0,5 16,2 202,0 500,0 20 15571 42 G 1 19,7 403,0 949,0 18
15535 50 G 0,5 18,0 240,0 580,0 20 15572 50 G 1 21,7 480,0 1092,0 18
15538 2 x 0,75 6,0 14,4 57,0 19 15573 65 G 1 30,9 624,0 1400,0 18
15539 3 G 0,75 6,3 21,6 72,0 19 15575 2 x 1,5 6,8 29,0 90,0 16
15540 4 G 0,75 6,8 29,0 97,0 19 15576 3 G 1,5 7,2 43,0 117,0 16
15541 5 G 0,75 7,4 36,0 119,0 19 15577 4 G 1,5 7,7 58,0 147,0 16
15542 7 G 0,75 8,7 50,0 165,0 19 15578 5 G 1,5 8,6 72,0 181,0 16
15543 8 G 0,75 9,5 58,0 189,0 19 15579 7 G 1,5 10,3 101,0 274,0 16
15544 10 G 0,75 10,7 72,0 214,0 19 15580 8 G 1,5 11,0 115,0 313,0 16
15545 12 G 0,75 10,9 86,0 247,0 19 15581 10 G 1,5 12,7 144,0 344,0 16
15546 14 G 0,75 11,5 101,0 283,0 19 15582 12 G 1,5 12,7 173,0 391,0 16
15547 18 G 0,75 12,7 130,0 356,0 19 15583 14 G 1,5 13,4 202,0 457,0 16
15548 21 G 0,75 13,4 151,0 502,0 19 15584 18 G 1,5 15,1 259,0 589,0 16
15549 25 G 0,75 15,0 180,0 698,0 19 15585 21 G 1,5 16,2 302,0 680,0 16
15550 30 G 0,75 15,8 216,0 720,0 19 15586 25 G 1,5 18,0 360,0 801,0 16
15551 34 G 0,75 17,2 245,0 770,0 19 15587 30 G 1,5 18,7 410,0 938,0 16
15552 42 G 0,75 18,5 302,0 840,0 19 15588 34 G 1,5 20,6 490,0 1048,0 16
15553 50 G 0,75 20,1 360,0 990,0 19 15589 42 G 1,5 22,4 605,0 1290,0 16
Continuation
167
Cables for Drag Chains / PUR Cables for Drag Chains
PUR-JZ-HF high flexible, cable for drag chains, abrasion and coolant resistant,
meter marking
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
15590 50 G 1,5 24,2 720,0 1520,0 16 15637 4G6 13,9 230,0 500,0 10
15591 61 G 1,5 32,4 889,0 1850,0 16 15638 5G6 15,4 288,0 580,0 10
15592 65 G 1,5 33,6 940,0 1970,0 16 15639 7G6 18,0 403,0 800,0 10
15620 2 x 2,5 8,5 48,0 128,0 14 15654 1 G 10 8,9 96,0 152,0 8
15621 3 G 2,5 9,0 72,0 160,0 14 15641 3 G 10 16,2 288,0 660,0 8
15622 4 G 2,5 9,9 96,0 200,0 14 15642 4 G 10 18,1 384,0 750,0 8
15623 5 G 2,5 11,0 120,0 268,0 14 15643 5 G 10 20,3 480,0 990,0 8
15624 7 G 2,5 12,8 168,0 357,0 14 15644 7 G 10 24,3 672,0 1300,0 8
15625 12 G 2,5 16,2 288,0 571,0 14 15655 1 G 16 10,0 154,0 215,0 6
15626 14 G 2,5 17,1 336,0 612,0 14 15645 4 G 16 21,1 614,0 1200,0 6
15627 18 G 2,5 19,1 432,0 800,0 14 15646 5 G 16 23,5 768,0 1500,0 6
15628 25 G 2,5 22,8 600,0 1100,0 14 15647 7 G 16 28,7 1075,0 1900,0 6
15630 2x4 10,1 77,0 190,0 12 15656 1 G 25 11,1 240,0 320,0 4
15631 3G4 10,9 115,0 250,0 12 15648 4 G 25 34,0 960,0 1700,0 4
15632 4G4 12,0 154,0 320,0 12 15649 4 G 35 37,0 1344,0 2300,0 2
15633 5G4 13,4 192,0 400,0 12 15650 4 G 50 44,0 1920,0 2500,0 1
15634 7G4 16,0 269,0 550,0 12 15651 4 G 70 53,0 2688,0 4600,0 2/0
15653 1G6 7,3 58,0 81,0 10 15652 4 G 95 59,0 3648,0 6400,0 3/0
15636 3G6 12,8 173,0 350,0 10
168
Cables for Drag Chains / PUR Cables for Drag Chains
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified" when
ordering.
screened analogue type:
MULTIFLEX 512-C-PUR ,
confer page 174
Application
The special cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics, for movable automated
machinery parts and multi-shift operation. Those cables are developed according to the newest state of technology improvement. These high flexible
control cables with sliding abilities guaranteed an optimum service life durabilities and also very economic by using the PP-core insulation and the
PUR-outer sheath. The PUR material is adhesion-low and cut-resistant. For applications which go beyond standard solutions (for example for composting
appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy
guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see
lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22501 2 x 0,5 5,5 9,6 38,0 20 22512 2 x 0,75 6,2 14,4 47,0 19
22502 3 G 0,5 5,8 14,4 46,0 20 22513 3 G 0,75 6,5 21,6 58,0 19
22503 4 G 0,5 6,4 19,0 59,0 20 22514 4 G 0,75 7,0 29,0 69,0 19
22504 5 G 0,5 7,0 24,0 68,0 20 22515 5 G 0,75 7,8 36,0 85,0 19
22505 7 G 0,5 8,1 33,6 88,0 20 22516 7 G 0,75 9,0 50,0 118,0 19
22506 12 G 0,5 9,9 58,0 131,0 20 22517 12 G 0,75 11,0 86,0 183,0 19
22507 18 G 0,5 11,5 86,0 197,0 20 22518 18 G 0,75 13,0 130,0 270,0 19
22508 20 G 0,5 12,0 96,0 260,0 20 22519 20 G 0,75 13,5 144,0 290,0 19
22509 25 G 0,5 13,7 120,0 282,0 20 22520 25 G 0,75 15,4 180,0 374,0 19
22510 30 G 0,5 14,3 144,0 315,0 20 22521 30 G 0,75 16,2 216,0 420,0 19
22511 36 G 0,5 15,3 172,0 374,0 20 22522 36 G 0,75 17,6 259,0 498,0 19
Continuation
169
Cables for Drag Chains / PUR Cables for Drag Chains
170
Cables for Drag Chains / PUR Cables for Drag Chains
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
screened analogue type:
MULTISPEED 500-C-PUR,
confer page 176
Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and wet rooms
and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are installed
there, where the problems appear for the application in permanent stresses e. g. in energy drag chains, industry robotics, production lines, automatic
control systems and permanent movable machinery parts for multi-shift operation. These cables are installed everywhere, where high requirements
for the flexibility, abrasion, oxygen and chemical resistance are necessary. For applications which go beyond standard solutions we recommend for
our especially developed enquiry sheet for energy guiding systems.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24119 2 x 0,5 4,3 9,6 41,0 20 24138 5G1 6,7 48,0 84,0 18
24120 3 G 0,5 4,6 14,4 48,0 20 24139 7G1 11,1 67,0 111,0 18
24121 4 G 0,5 5,0 19,0 62,0 20 24140 12 G 1 12,0 115,0 200,0 18
24122 5 G 0,5 5,4 24,0 70,0 20 24141 18 G 1 14,8 173,0 286,0 18
24123 7 G 0,5 8,9 33,6 88,0 20 24142 25 G 1 17,2 240,0 370,0 18
24124 12 G 0,5 9,7 58,0 131,0 20 24143 3 G 1,5 6,4 43,0 81,0 16
24125 18 G 0,5 11,8 86,0 204,0 20 24144 4 G 1,5 7,0 58,0 102,0 16
24126 25 G 0,5 13,9 120,0 266,0 20 24145 5 G 1,5 7,8 72,0 121,0 16
24127 3 G 0,75 5,2 21,6 51,0 19 24146 7 G 1,5 13,0 101,0 164,0 16
24128 4 G 0,75 5,6 29,0 68,0 19 24147 12 G 1,5 14,2 173,0 293,0 16
24129 5 G 0,75 6,3 36,0 73,0 19 24148 18 G 1,5 17,5 259,0 450,0 16
24130 7 G 0,75 10,3 50,0 92,0 19 24149 25 G 1,5 20,1 360,0 631,0 16
24131 12 G 0,75 11,0 86,0 170,0 19 24150 4 G 2,5 8,8 86,0 173,0 14
24132 18 G 0,75 13,9 130,0 257,0 19 24151 5 G 2,5 9,8 120,0 220,0 14
24133 25 G 0,75 15,9 180,0 280,0 19 24152 7 G 2,5 16,1 168,0 290,0 14
24134 36 G 0,75 19,6 260,0 411,0 19 24153 12 G 2,5 17,8 288,0 504,0 14
24135 42 G 0,75 21,5 302,0 608,0 19 24154 18 G 2,5 21,8 432,0 719,0 14
24136 3G1 5,4 29,0 59,0 18 24155 25 G 2,5 24,4 600,0 940,0 14
24137 4G1 5,9 38,0 71,0 18
171
Cables for Drag Chains / PUR Cables for Drag Chains
Application
PUR-JZ-HF-YCP is a highly robust and tare and abrasion resistant cable with excellent resistance properties to mineral oils and cooling fluids, thus
making it an ideal choice for installation in most types of industrial machinery as well as in steel works and rolling mills, etc. in fact, wherever you may
need a cable to cope with especially critical situations. Easy to install, thanks to its high degree of flexibility. Its high abrasion resistance and good
flexing ability make it quick and easy to install and, with its low bending radius, ideal for use with cable trays. This screened cable is ideal for use in
data signal transmission free from interferences for measurement and control engineering technology. For applications which go beyond standard
solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially
developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection
table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22400 2 x 0,5 7,5 30,0 90,0 20 22417 2 x 0,75 7,5 39,0 106,0 19
22401 3 G 0,5 7,8 38,0 104,0 20 22418 3 G 0,75 7,8 49,0 120,0 19
22402 4 G 0,5 7,8 48,0 123,0 20 22419 4 G 0,75 8,5 60,0 150,0 19
22403 5 G 0,5 8,5 65,0 131,0 20 22420 5 G 0,75 9,1 70,0 158,0 19
22404 7 G 0,5 9,5 70,0 172,0 20 22421 7 G 0,75 10,9 95,0 205,0 19
22405 8 G 0,5 10,4 81,0 195,0 20 22422 8 G 0,75 11,5 104,0 272,0 19
22406 10 G 0,5 11,4 94,0 230,0 20 22423 10 G 0,75 13,0 110,0 290,0 19
22407 12 G 0,5 11,6 110,0 250,0 20 22424 12 G 0,75 13,2 141,0 304,0 19
22408 14 G 0,5 12,0 135,0 280,0 20 22425 14 G 0,75 13,7 163,0 380,0 19
22409 18 G 0,5 13,4 157,0 321,0 20 22426 18 G 0,75 15,2 211,0 418,0 19
22410 21 G 0,5 14,8 175,0 380,0 20 22427 21 G 0,75 16,4 274,0 485,0 19
22411 25 G 0,5 16,1 240,0 445,0 20 22428 25 G 0,75 18,2 322,0 578,0 19
22412 30 G 0,5 16,4 275,0 509,0 20 22429 30 G 0,75 18,6 414,0 630,0 19
22413 34 G 0,5 17,8 305,0 560,0 20 22430 34 G 0,75 20,0 473,0 720,0 19
22414 42 G 0,5 19,1 330,0 780,0 20 22431 42 G 0,75 21,5 583,0 780,0 19
22415 50 G 0,5 20,6 393,0 960,0 20 22432 50 G 0,75 23,7 626,0 954,0 19
22416 61 G 0,5 23,0 541,0 1050,0 20 22433 61 G 0,75 25,9 763,0 1085,0 19
Continuation
172
Cables for Drag Chains / PUR Cables for Drag Chains
173
Cables for Drag Chains / PUR Cables for Drag Chains
Application
The special screened cables for drag chains are mainly applied for impulse transmission to prevent external interference effects and used for permanent
flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts and multi-shift operation. Those cables
are developed according to the newest state of technology improvement. These high flexible control cables with sliding abilities guaranteed an optimum
service life durabilities and also very economic by using the PP-core insulation and the PUR-outer sheath which is adhesive-free and cut-resistant.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22571 2 x 0,5 8,3 30,0 90,0 20 22577 18 G 0,5 14,7 157,0 325,0 20
22572 3 G 0,5 8,5 38,0 105,0 20 22578 20 G 0,5 15,4 167,0 350,0 20
22573 4 G 0,5 9,0 50,0 124,0 20 22579 25 G 0,5 17,1 240,0 450,0 20
22574 5 G 0,5 9,7 65,0 132,0 20 22580 30 G 0,5 17,9 273,0 510,0 20
22575 7 G 0,5 11,1 70,0 175,0 20 22581 36 G 0,5 19,2 306,0 580,0 20
22576 12 G 0,5 12,7 100,0 250,0 20
Continuation
174
Cables for Drag Chains / PUR Cables for Drag Chains
175
Cables for Drag Chains / PUR Cables for Drag Chains
Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and wet rooms
and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are installed
there, where the problems appear for the application in permanent stresses e. g. in energy drag chains. These cables are installed everywhere, where
high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary. These screened cables are particularly suitable for the
interference-free transmission in instrumentation and control engineering applications. For applications which go beyond standard solutions we
recommend for our especially developed enquiry sheet for energy guiding systems.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24156 2 x 0,5 6,4 30,0 90,0 20 24173 2x1 7,1 50,0 120,0 18
24157 3 G 0,5 6,7 36,0 104,0 20 24174 3G1 7,6 59,0 140,0 18
24158 4 G 0,5 7,2 42,0 118,0 20 24175 4G1 8,1 70,0 167,0 18
24159 5 G 0,5 7,6 48,0 148,0 20 24176 5G1 8,9 84,0 201,0 18
24160 7 G 0,5 11,4 64,0 184,0 20 24177 7G1 13,6 106,0 256,0 18
24161 9 G 0,5 11,4 80,0 219,0 20 24178 12 G 1 14,6 174,0 417,0 18
24162 12 G 0,5 12,4 105,0 276,0 20 24179 18 G 1 18,4 240,0 557,0 18
24163 18 G 0,5 14,7 137,0 378,0 20 24180 25 G 1 21,0 332,0 766,0 18
24164 25 G 0,5 17,1 210,0 547,0 20 24181 3 G 1,5 8,4 75,0 170,0 16
24165 2 x 0,75 6,8 40,0 100,0 19 24182 4 G 1,5 9,1 90,0 204,0 16
24166 3 G 0,75 7,3 48,0 117,0 19 24183 5 G 1,5 10,2 108,0 236,0 16
24167 4 G 0,75 7,8 55,0 143,0 19 24184 7 G 1,5 15,7 157,0 309,0 16
24168 5 G 0,75 8,3 66,0 167,0 19 24185 12 G 1,5 17,4 240,0 509,0 16
24169 7 G 0,75 12,7 85,0 229,0 19 24186 18 G 1,5 21,3 355,0 718,0 16
24170 12 G 0,75 13,7 135,0 319,0 19 24187 25 G 1,5 24,3 448,0 944,0 16
24171 18 G 0,75 17,1 190,0 492,0 19 24188 4 G 2,5 11,2 134,0 280,0 14
24172 25 G 0,75 19,5 275,0 659,0 19 24189 5 G 2,5 12,2 175,0 346,0 14
24190 7 G 2,5 19,7 229,0 410,0 14
176
Cables for Drag Chains / TPE Cables for Drag Chains
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified" when
ordering.
screened analogue type:
MULTISPEED 500-C-TPE,
confer page 179
Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and wet rooms
and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are installed
there, where the problems appear for the application in permanent stresses e. g. in energy drag chains, industry robotics, production lines, automatic
control systems and permanent movable machinery parts for multi-shift operation. For applications which go beyond standard solutions we recommend
for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24191 2 x 0,5 4,7 9,6 42,0 20 24199 2 x 0,75 5,0 14,4 47,0 19
24192 3 G 0,5 5,0 14,4 49,0 20 24200 3 G 0,75 5,2 21,6 55,0 19
24193 4 G 0,5 5,4 19,0 63,0 20 24201 4 G 0,75 6,0 29,0 70,0 19
24194 5 G 0,5 5,8 24,0 70,0 20 24202 5 G 0,75 6,5 36,0 74,0 19
24195 7 G 0,5 8,9 33,6 90,0 20 24203 7 G 0,75 10,3 50,0 95,0 19
24196 12 G 0,5 9,7 58,0 134,0 20 24204 12 G 0,75 11,0 86,0 174,0 19
24197 18 G 0,5 11,8 86,0 209,0 20 24205 18 G 0,75 13,9 130,0 261,0 19
24198 25 G 0,5 13,9 120,0 270,0 20 24206 25 G 0,75 15,9 180,0 290,0 19
24207 36 G 0,75 19,6 260,0 419,0 19
24208 42 G 0,75 21,5 302,0 614,0 19
Continuation
177
Cables for Drag Chains / TPE Cables for Drag Chains
178
Cables for Drag Chains / TPE Cables for Drag Chains
Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and wet rooms
and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are installed
there, where the problems appear for the application in permanent stresses e. g. in energy drag chains. These cables are installed everywhere, where
high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24236 2 x 0,5 6,5 30,0 85,0 20 24255 4G1 8,1 70,0 160,0 18
24237 3 G 0,5 6,7 36,0 99,0 20 24256 5G1 8,9 84,0 195,0 18
24238 4 G 0,5 7,2 42,0 107,0 20 24257 7G1 13,6 106,0 247,0 18
24239 5 G 0,5 7,6 48,0 140,0 20 24258 12 G 1 14,8 174,0 411,0 18
24240 7 G 0,5 11,4 64,0 176,0 20 24259 18 G 1 18,4 240,0 547,0 18
24241 10 G 0,5 11,4 80,0 204,0 20 24260 25 G 1 21,0 332,0 754,0 18
24242 12 G 0,5 12,4 105,0 261,0 20 24261 3 G 1,5 8,4 75,0 160,0 16
24243 18 G 0,5 14,7 137,0 360,0 20 24262 4 G 1,5 9,2 90,0 194,0 16
24244 25 G 0,5 17,1 320,0 530,0 20 24263 5 G 1,5 10,2 108,0 220,0 16
24245 2 x 0,75 7,0 40,0 97,0 19 24264 7 G 1,5 15,7 157,0 294,0 16
24246 3 G 0,75 7,3 48,0 110,0 19 24265 12 G 1,5 17,4 240,0 490,0 16
24247 4 G 0,75 7,8 55,0 139,0 19 24266 18 G 1,5 21,3 355,0 704,0 16
24248 5 G 0,75 8,3 66,0 160,0 19 24267 25 G 1,5 24,3 448,0 930,0 16
24249 7 G 0,75 12,7 85,0 219,0 19 24268 4 G 2,5 11,2 134,0 260,0 14
24250 12 G 0,75 13,7 135,0 307,0 19 24269 5 G 2,5 12,2 175,0 330,0 14
24251 18 G 0,75 17,1 190,0 490,0 19 24270 7 G 2,5 19,5 229,0 406,0 14
24252 25 G 0,75 19,5 275,0 640,0 19 24271 12 G 2,5 21,7 390,0 990,0 14
24253 2x1 7,3 50,0 115,0 18 24272 4G4 13,6 194,0 355,0 12
24254 3G1 7,6 59,0 131,0 18
179
BIO-OIL & MICROBE-RESISTANT CABLES
DRAG CHAIN CABLES
Cables for Drag Chains / Bio-Oil and microbial resistant Cables for Drag Chains
Application
HELUKABEL BIOFLEX-500-JZ-HF is an extremely robust and high flexible control cable with high abrasion and tear resistant properties. Due to its
high resistance to Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as in
the steel industry for difficult and problem areas. Suitable in combination with cable trays in dry, moist and wet rooms and outdoor installation. The
high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying. 1) For the critical applications we advise for consultation.
For applications which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems. Before
installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25761 2 x 0,5 5,4 9,6 45,0 20 25796 10 G 1,5 13,4 144,0 344,0 16
25762 3 G 0,5 5,9 14,4 56,0 20 25797 12 G 1,5 13,4 173,0 391,0 16
25763 4 G 0,5 6,3 19,1 69,0 20 25798 14 G 1,5 14,3 202,0 457,0 16
25764 5 G 0,5 6,9 24,0 92,0 20 25799 18 G 1,5 16,0 259,0 589,0 16
25765 7 G 0,5 7,8 33,6 126,0 20 25800 25 G 1,5 19,5 360,0 801,0 16
25766 10 G 0,5 9,6 48,0 158,0 20 25801 2 x 2,5 8,6 48,0 128,0 14
25767 12 G 0,5 10,3 58,0 176,0 20 25802 3 G 2,5 9,3 72,0 160,0 14
25768 14 G 0,5 10,3 67,0 212,0 20 25803 4 G 2,5 10,3 96,0 200,0 14
25769 18 G 0,5 11,5 86,4 283,0 20 25804 5 G 2,5 11,5 120,0 268,0 14
25770 25 G 0,5 13,6 120,0 330,0 20 25805 7 G 2,5 13,4 168,0 357,0 14
25771 2 x 0,75 5,9 14,4 57,0 19 25806 12 G 2,5 17,0 288,0 571,0 14
25772 3 G 0,75 6,2 21,6 72,0 19 25807 14 G 2,5 18,5 336,0 612,0 14
25773 4 G 0,75 6,7 29,0 97,0 19 25808 18 G 2,5 20,0 432,0 800,0 14
25774 5 G 0,75 7,3 36,0 119,0 19 25809 25 G 2,5 29,6 600,0 1100,0 14
25775 7 G 0,75 8,7 50,0 165,0 19 25810 2x4 10,4 77,0 190,0 12
25776 10 G 0,75 10,5 72,0 214,0 19 25811 3G4 11,2 115,0 250,0 12
25777 12 G 0,75 11,0 86,0 247,0 19 25812 4G4 12,5 154,0 320,0 12
25778 14 G 0,75 11,4 101,0 283,0 19 25813 5G4 13,8 192,0 400,0 12
25779 18 G 0,75 12,6 130,0 356,0 19 25814 3G6 13,0 173,0 350,0 10
25780 25 G 0,75 15,2 180,0 698,0 19 25815 4G6 14,7 230,0 500,0 10
25781 2x1 6,6 19,0 64,0 18 25816 5G6 16,0 288,0 580,0 10
25782 3G1 7,0 29,0 83,0 18 25817 3 G 10 17,4 288,0 660,0 8
25783 4G1 7,6 38,5 113,0 18 25819 5 G 10 21,3 480,0 990,0 8
25784 5G1 8,2 48,0 137,0 18 25820 4 G 16 23,2 614,0 1200,0 6
25785 7G1 9,6 67,0 191,0 18 25821 4 G 25 34,0 960,0 1700,0 4
25786 10 G 1 11,6 96,0 251,0 18 25822 4 G 35 37,0 1344,0 2300,0 2
25787 12 G 1 12,0 115,0 294,0 18 25823 4 G 50 44,0 1920,0 2500,0 1
25788 14 G 1 13,0 134,0 337,0 18 25824 4 G 70 53,0 2688,0 4600,0 2/0
25789 18 G 1 14,5 173,0 420,0 18 25825 4 G 95 59,0 3648,0 6400,0 3/0
25790 25 G 1 17,6 240,0 600,0 18
25791 2 x 1,5 7,1 29,0 90,0 16
25792 3 G 1,5 7,5 43,0 117,0 16
25793 4 G 1,5 8,2 58,0 147,0 16
25794 5 G 1,5 9,0 72,0 181,0 16
25795 7 G 1,5 10,8 101,0 274,0 16
181
Cables for Drag Chains / Bio-Oil and microbial resistant Cables for Drag Chains
Application
HELUKABEL BIOFLEX-500-JZ-HF-C is an extremely robust and high flexible control cable with high abrasion and tear resistant properties. Due to
its high resistance to Bio-fuel, Bio-oil and coolant emulsions. It is especially suited for use in the machine, tool making and plant industries as well as
in the steel industry for difficult and problem areas. Suitable in combination with cable trays in dry, moist and wet rooms and outdoor installation. The
high flexibility of this cable type makes it quick and easy to install. Suitable for outdoor lying. These screened cables are particularly suitable for the
interference-free transmission in instrumentation and control engineering applications (electromagnetic compatibillity). For the critical applications
we advise for consultation. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with
extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in
cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25826 2 x 0,5 7,5 47,0 90,0 20 25849 5G1 11,8 99,0 188,0 18
25827 3 G 0,5 7,8 52,0 104,0 20 25850 7G1 12,7 125,0 235,0 18
25828 4 G 0,5 8,2 55,0 123,0 20 25851 10 G 1 14,6 178,0 340,0 18
25829 5 G 0,5 9,9 65,0 131,0 20 25852 12 G 1 15,5 186,0 358,0 18
25830 7 G 0,5 10,0 84,0 172,0 20 25853 14 G 1 16,7 250,0 415,0 18
25831 10 G 0,5 11,3 115,0 230,0 20 25854 18 G 1 18,0 280,0 500,0 18
25832 12 G 0,5 12,5 117,0 250,0 20 25855 25 G 1 21,0 378,0 678,0 18
25833 14 G 0,5 13,2 148,0 280,0 20 25856 2 x 1,5 10,5 79,0 141,0 16
25834 18 G 0,5 14,5 157,0 321,0 20 25857 3 G 1,5 10,8 94,0 164,0 16
25835 25 G 0,5 16,8 227,0 445,0 20 25858 4 G 1,5 11,5 113,0 220,0 16
25836 2 x 0,75 8,3 53,0 106,0 19 25859 5 G 1,5 12,5 129,0 233,0 16
25837 3 G 0,75 8,5 62,0 120,0 19 25860 7 G 1,5 13,2 170,0 323,0 16
25838 4 G 0,75 9,5 77,0 150,0 19 25861 8 G 1,5 14,4 226,0 369,0 16
25839 5 G 0,75 10,8 86,0 158,0 19 25862 10 G 1,5 14,9 258,0 461,0 16
25840 7 G 0,75 11,5 107,0 205,0 19 25863 12 G 1,5 16,2 280,0 481,0 16
25841 10 G 0,75 13,1 148,0 290,0 19 25864 14 G 1,5 18,1 340,0 561,0 16
25842 12 G 0,75 14,0 156,0 304,0 19 25865 18 G 1,5 20,3 395,0 672,0 16
25843 14 G 0,75 15,3 214,0 380,0 19 25866 21 G 1,5 21,7 461,0 780,0 16
25844 18 G 0,75 17,3 235,0 418,0 19 25867 25 G 1,5 23,1 533,0 927,0 16
25845 25 G 0,75 18,7 313,0 578,0 19 25868 2 x 2,5 11,8 96,0 185,0 14
25846 2x1 10,0 60,0 116,0 18 25869 3 G 2,5 13,0 150,0 278,0 14
25847 3G1 10,2 70,0 135,0 18 25870 4 G 2,5 14,0 174,0 370,0 14
25848 4G1 11,0 86,0 178,0 18 25871 5 G 2,5 15,1 200,0 412,0 14
Continuation
182
Cables for Drag Chains / Bio-Oil and microbial resistant Cables for Drag Chains
183
Cables for Drag Chains / microbial resistant Cables for Drag Chains
Application
HELUKABEL KOMPOSPEED JZ-HF-500 control cable is significant due to its resistance against microbes. This cable is specially installed in rubbish,
sewage-treatment plants, composting works, animal stalls and greenhouses. Suitable for installation for flexible use for medium mechanical, stresses
with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside. The high flexibility of this cable type
makes it quick and easy to install. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors
with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation
in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
26307 2 x 0,5 5,0 9,6 42,0 20 26331 2 x 1,5 6,4 29,0 88,0 16
26308 3 G 0,5 5,3 14,4 51,0 20 26332 3 G 1,5 6,8 43,0 104,0 16
26309 4 G 0,5 5,7 19,1 62,0 20 26333 4 G 1,5 7,4 58,0 137,0 16
26310 5 G 0,5 6,4 24,0 88,0 20 26334 5 G 1,5 8,3 72,0 171,0 16
26311 7 G 0,5 7,5 33,6 119,0 20 26335 7 G 1,5 9,9 101,0 264,0 16
26312 12 G 0,5 9,2 58,0 166,0 20 26336 12 G 1,5 12,1 173,0 381,0 16
26313 18 G 0,5 11,1 86,4 273,0 20 26337 18 G 1,5 14,5 259,0 579,0 16
26314 25 G 0,5 13,4 120,0 330,0 20 26338 25 G 1,5 17,8 360,0 789,0 16
26315 2 x 0,75 5,4 14,4 53,0 19 26339 2 x 2,5 7,7 48,0 118,0 14
26316 3 G 0,75 5,7 21,6 70,0 19 26340 3 G 2,5 8,4 72,0 172,0 14
26317 4 G 0,75 6,4 29,0 92,0 19 26341 4 G 2,5 9,1 96,0 197,0 14
26318 5 G 0,75 7,0 36,0 116,0 19 26342 5 G 2,5 10,2 120,0 258,0 14
26319 7 G 0,75 8,3 50,0 159,0 19 26343 7 G 2,5 12,2 168,0 347,0 14
26320 12 G 0,75 10,2 86,0 241,0 19 26344 12 G 2,5 15,2 288,0 561,0 14
26321 18 G 0,75 12,1 130,0 346,0 19 26345 18 G 2,5 18,1 432,0 791,0 14
26322 25 G 0,75 14,9 180,0 681,0 19 26346 25 G 2,5 22,5 600,0 1090,0 14
26323 2x1 5,7 19,2 60,0 18
26324 3G1 6,0 29,0 79,0 18
26325 4G1 6,8 38,5 107,0 18
26326 5G1 7,4 48,0 127,0 18
26327 7G1 8,8 67,0 181,0 18
26328 12 G 1 10,8 115,0 284,0 18
26329 18 G 1 13,0 173,0 397,0 18
26330 25 G 1 15,8 240,0 491,0 18
184
Cables for Drag Chains / microbial resistant Cables for Drag Chains
Application
HELUKABEL KOMPOSPEED JZ-HF-500-C control cable is significant due to its resistance against microbes. This cable is specially installed in rubbish,
sewage-treatment plants, composting works, animal stalls and greenhouses. The inner sheaths of those cables raise the mechanical stress. For medium
mechanical, stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside. This screened
cable is ideal for use in data signal transmission free from interferences for measurement and control engineering technology. For applications which
go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
26347 2 x 0,5 6,9 47,0 90,0 20 26367 5G1 9,5 99,0 179,0 18
26348 3 G 0,5 7,2 52,0 101,0 20 26368 7G1 10,9 125,0 229,0 18
26349 4 G 0,5 7,8 55,0 119,0 20 26369 12 G 1 13,1 186,0 348,0 18
26350 5 G 0,5 8,3 65,0 121,0 20 26370 18 G 1 15,4 280,0 498,0 18
26351 6 G 0,5 9,1 70,0 144,0 20 26371 25 G 1 18,6 378,0 669,0 18
26352 7 G 0,5 9,6 84,0 169,0 20 26372 2 x 1,5 8,3 79,0 141,0 16
26353 12 G 0,5 11,3 117,0 250,0 20 26373 3 G 1,5 8,7 94,0 162,0 16
26354 18 G 0,5 13,5 157,0 321,0 20 26374 4 G 1,5 9,5 113,0 210,0 16
26355 25 G 0,5 15,8 227,0 445,0 20 26375 5 G 1,5 10,2 129,0 233,0 16
26356 2 x 0,75 7,3 53,0 106,0 19 26376 7 G 1,5 12,2 170,0 317,0 16
26357 3 G 0,75 7,8 62,0 116,0 19 26377 12 G 1,5 14,5 280,0 471,0 16
26358 4 G 0,75 8,3 77,0 140,0 19 26378 18 G 1,5 16,9 395,0 664,0 16
26359 5 G 0,75 9,1 86,0 148,0 19 26379 25 G 1,5 20,6 533,0 914,0 16
26360 7 G 0,75 10,2 107,0 198,0 19 26380 2 x 2,5 9,8 96,0 182,0 14
26361 12 G 0,75 12,6 156,0 294,0 19 26381 3 G 2,5 10,5 150,0 264,0 14
26362 18 G 0,75 14,5 235,0 391,0 19 26382 4 G 2,5 11,2 174,0 350,0 14
26363 25 G 0,75 17,3 313,0 562,0 19 26383 5 G 2,5 12,6 200,0 394,0 14
26364 2x1 7,8 60,0 110,0 18 26384 7 G 2,5 14,8 240,0 450,0 14
26365 3G1 8,1 70,0 131,0 18 26385 12 G 2,5 18,0 410,0 712,0 14
26366 4G1 8,7 86,0 171,0 18
185
DATA DRAG CHAIN CABLES
Cables for Drag Chains / Data-Cables for Drag Chains
Application
The ideal cable for use in cable trays. This high flexible cable is ideal for all areas requiring a high and fast flexing cable including the machine industries,
robotics and all areas of highly mobile machine parts. The long working life offers a secure performance as well as economy. For applications which
go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49550 2 x 0,14 3,5 2,8 23,0 26 49567 12 x 0,25 7,5 30,1 95,0 24
49551 3 x 0,14 3,7 4,1 25,0 26 49568 14 x 0,25 7,9 35,0 107,0 24
49552 4 x 0,14 3,9 5,6 30,0 26 49569 18 x 0,25 8,9 45,0 130,0 24
49553 5 x 0,14 4,2 7,0 35,0 26 49570 24 x 0,25 10,4 60,0 170,0 24
49554 7 x 0,14 4,8 9,8 49,0 26 49571 25 x 0,25 10,5 62,5 177,0 24
49555 10 x 0,14 6,2 14,0 64,0 26 49572 2 x 0,34 4,6 6,8 33,0 22
49556 12 x 0,14 6,3 16,8 71,0 26 49573 3 x 0,34 4,8 10,2 42,0 22
49557 14 x 0,14 6,6 19,6 77,0 26 49574 4 x 0,34 5,2 13,6 56,0 22
49558 18 x 0,14 7,2 25,2 90,0 26 49575 5 x 0,34 6,1 17,0 64,0 22
49559 24 x 0,14 8,5 33,6 119,0 26 49576 7 x 0,34 7,0 23,8 84,0 22
49560 25 x 0,14 8,6 35,0 124,0 26 49577 10 x 0,34 8,4 34,0 116,0 22
49561 2 x 0,25 4,2 5,0 28,0 24 49578 12 x 0,34 8,5 40,8 133,0 22
49562 3 x 0,25 4,4 7,5 33,0 24 49579 14 x 0,34 9,0 47,6 150,0 22
49563 4 x 0,25 4,7 10,0 39,0 24 49580 18 x 0,34 10,1 61,2 182,0 22
49564 5 x 0,25 5,6 12,5 50,0 24 49581 24 x 0,34 12,0 81,5 240,0 22
49565 7 x 0,25 6,1 17,5 63,0 24 49582 25 x 0,34 12,2 85,0 250,0 22
49566 10 x 0,25 7,2 25,0 83,0 24
187
Cables for Drag Chains / Data-Cables for Drag Chains
Application
The ideal cable for use in cable trays. This high flexible cable is ideal for all areas requiring a high and fast flexing cable including the machine industries,
robotics and all areas of highly mobile machine parts. The long working life offers a secure performance as well as economy. For applications which
go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49620 2 x 0,14 4,0 11,2 33,0 26 49638 14 x 0,25 8,5 64,2 140,0 24
49621 3 x 0,14 4,2 14,1 36,0 26 49639 18 x 0,25 9,5 78,4 166,0 24
49622 4 x 0,14 4,4 15,5 41,0 26 49640 24 x 0,25 11,0 89,9 210,0 24
49623 5 x 0,14 4,7 18,3 46,0 26 49641 25 x 0,25 11,1 101,0 220,0 24
49624 7 x 0,14 5,3 27,6 70,0 26 49642 2 x 0,34 5,2 16,1 46,0 22
49625 10 x 0,14 6,7 39,3 88,0 26 49643 3 x 0,34 5,4 28,7 62,0 22
49626 12 x 0,14 6,8 41,1 97,0 26 49644 4 x 0,34 5,8 35,7 80,0 22
49627 14 x 0,14 7,1 45,3 105,0 26 49645 5 x 0,34 6,7 39,1 88,0 22
49628 18 x 0,14 7,7 54,1 122,0 26 49646 7 x 0,34 7,6 52,7 116,0 22
49629 24 x 0,14 9,0 66,3 156,0 26 49647 10 x 0,34 9,0 67,4 156,0 22
49630 25 x 0,14 9,1 68,4 162,0 26 49648 12 x 0,34 9,1 76,4 167,0 22
49631 2 x 0,25 4,7 14,9 39,0 24 49649 14 x 0,34 9,6 85,3 195,0 22
49632 3 x 0,25 4,9 18,8 45,0 24 49650 18 x 0,34 10,7 99,7 225,0 22
49633 4 x 0,25 5,2 21,3 52,0 24 49651 24 x 0,34 12,6 147,1 312,0 22
49634 5 x 0,25 5,6 31,0 70,0 24 49652 25 x 0,34 12,8 155,0 325,0 22
49635 7 x 0,25 6,7 39,6 88,0 24
49636 10 x 0,25 7,8 53,9 114,0 24
49637 12 x 0,25 8,1 59,1 128,0 24
188
Cables for Drag Chains / Data-Cables for Drag Chains
Application
Perfect for use with cable trays. This highly flexible PUR control cable is ideal for use wherever frequent high flexing motion is required, e. g. in robotics
or all moving parts. The long working life of this cable makes it both efficient and economic. For applications which go beyond standard solutions (for
example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for
drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49583 2 x 0,14 3,5 2,8 22,0 26 49600 12 x 0,25 7,6 30,1 91,0 24
49584 3 x 0,14 3,7 4,1 24,0 26 49601 14 x 0,25 7,9 35,0 102,0 24
49585 4 x 0,14 3,9 5,6 29,0 26 49602 18 x 0,25 8,9 45,0 125,0 24
49586 5 x 0,14 4,2 7,0 33,0 26 49603 24 x 0,25 10,0 60,0 163,0 24
49587 7 x 0,14 4,9 9,8 47,0 26 49604 25 x 0,25 10,6 62,5 170,0 24
49588 10 x 0,14 6,2 14,0 59,0 26 49605 2 x 0,34 4,5 6,8 32,0 22
49589 12 x 0,14 6,4 16,8 67,0 26 49606 3 x 0,34 4,9 10,2 40,0 22
49590 14 x 0,14 6,6 19,6 74,0 26 49607 4 x 0,34 5,3 13,6 55,0 22
49591 18 x 0,14 7,3 25,2 86,0 26 49608 5 x 0,34 5,8 17,0 60,0 22
49592 24 x 0,14 8,5 33,6 115,0 26 49609 7 x 0,34 6,9 23,8 80,0 22
49593 25 x 0,14 8,6 35,0 120,0 26 49610 10 x 0,34 8,4 34,0 112,0 22
49594 2 x 0,25 4,1 5,0 27,0 24 49611 12 x 0,34 8,6 40,8 127,0 22
49595 3 x 0,25 4,3 7,5 33,0 24 49612 14 x 0,34 9,0 47,6 142,0 22
49596 4 x 0,25 4,8 10,0 40,0 24 49613 18 x 0,34 10,1 61,2 175,0 22
49597 5 x 0,25 5,2 12,5 48,0 24 49614 24 x 0,34 12,0 81,5 229,0 22
49598 7 x 0,25 6,2 17,5 60,0 24 49615 25 x 0,34 12,2 85,0 238,0 22
49599 10 x 0,25 7,4 25,0 79,0 24
189
Cables for Drag Chains / Data-Cables for Drag Chains
Application
Used for installation in dry, moist and wet environments as well as for outdoors, for free movement without forced motion and for flexible routing
without forced motion, for proven use as drag-chain cables. Suitable as a highly flexible control cable for fast hoisting and bending stresses in machinery
and tooling construction, in robotics engineering and for continuously moving machinery parts. The long working life of this cable makes it both
efficient and economic. The copper braided screening offers effective protection from both internal and external interference. For applications which
go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
49653 2 x 0,14 4,1 11,2 32,0 26 49670 12 x 0,25 8,4 59,1 124,0 24
49654 3 x 0,14 4,3 14,1 35,0 26 49671 14 x 0,25 8,7 64,2 135,0 24
49655 4 x 0,14 4,5 15,5 40,0 26 49672 18 x 0,25 9,5 78,4 160,0 24
49656 5 x 0,14 4,8 18,3 45,0 26 49673 24 x 0,25 11,0 89,9 202,0 24
49657 7 x 0,14 5,7 27,8 66,0 26 49674 25 x 0,25 11,1 101,0 211,0 24
49658 10 x 0,14 6,7 39,3 86,0 26 49675 2 x 0,34 5,0 18,1 45,0 22
49659 12 x 0,14 6,9 42,1 94,0 26 49676 3 x 0,34 5,4 28,7 60,0 22
49660 14 x 0,14 7,1 45,3 102,0 26 49677 4 x 0,34 6,2 35,7 76,0 22
49661 18 x 0,14 7,8 54,1 118,0 26 49678 5 x 0,34 6,7 39,1 82,0 22
49662 24 x 0,14 9,0 66,3 149,0 26 49679 7 x 0,34 7,6 52,7 110,0 22
49663 25 x 0,14 9,1 68,4 156,0 26 49680 10 x 0,34 9,2 67,4 148,0 22
49664 2 x 0,25 4,6 14,9 38,0 24 49681 12 x 0,34 9,4 76,4 166,0 22
49665 3 x 0,25 4,8 18,8 44,0 24 49682 14 x 0,34 10,0 85,5 185,0 22
49666 4 x 0,25 5,3 21,3 51,0 24 49683 18 x 0,34 10,9 99,7 216,0 22
49667 5 x 0,25 5,7 31,0 68,0 24 49684 24 x 0,34 12,6 147,1 300,0 22
49668 7 x 0,25 6,7 39,6 82,0 24 49685 25 x 0,34 12,8 155,0 313,0 22
49669 10 x 0,25 8,2 53,9 110,0 24
190
SUPER-PAAR-TRONIC-C-PUR
cableforDragChains,halogen-free,EMC-preferredtype,metermarking
Application
ThesepairstrandedandoverallscreenedspecialcablesforDragChainsoffertheoperationalpossibilitieswheretheouterelectricalinfluencesathigh
frequencecauseinterferenceofimpulsetransmission,areappliedforpermanentflexibleoperationsinmachineries,machinetools,robottechnics,
formovableautomatedmachinerypartsandmulti-shift-operationasatransmission-cable.Thesehighflexibledatacablesaredevelopedaccording
totheneweststateoftechnologyimprovementandwithitsslidingabilitiesbyusingthePP-coreinsulationandadhesion-lowandcut-resistant
PUR-outersheath,guaranteedanoptimumlifedurabilitiesandhighlyeconomic.Forapplicationswhichgobeyondstandardsolutions(forexample
forcompostingappliancesorhighshelfconveyorswithextremelyhighprocessingspeedsetc.)werecommendforourespeciallydevelopedenquiry
sheetforenergyguidingsystems.Beforeinstallationincabletrayspleasereadtheinstructions.FurthertechnicaldetailsseeselectiontableforDrag
Chaincables,seeleadtext.
EMC =Electromagneticcompatibillity
TooptimizetheEMCfeatureswerecommendalargeroundcontactofthecopperbraidingonbothends.
=TheproductisconformedwiththeECLow-VoltageDirective2006/95/EC.
Partno. No.pairsx Outer Cop. Weight AWG-No. Partno. No.pairsx Outer Cop. Weight AWG-No.
cross-sec. app.mm weight app. cross-sec. app.mm weight app.
mm kg/km kg/km mm kg/km kg/km
19101 1 x2 x0,25 4,9 14,0 28,0 24 19128 1 x2 x0,75 6,5 34,0 61,0 19
25.01.2016/Dimensionsandspecificationsmaybechangedwithoutpriornotice.
19102 2 x2 x0,25 6,8 32,0 61,0 24 19129 2 x2 x0,75 9,3 60,0 113,0 19
19103 3 x2 x0,25 7,2 38,4 73,0 24 19130 3 x2 x0,75 9,8 85,7 158,0 19
19104 4 x2 x0,25 7,7 43,2 90,0 24 19131 4 x2 x0,75 10,6 93,6 173,0 19
19105 5 x2 x0,25 8,6 51,5 105,0 24 19132 5 x2 x0,75 11,7 113,0 203,0 19
19106 6 x2 x0,25 9,2 71,8 133,0 24 19133 6 x2 x0,75 12,7 130,4 231,0 19
19107 8 x2 x0,25 10,6 74,4 156,0 24 19134 8 x2 x0,75 14,9 192,2 343,0 19
19108 10 x2 x0,25 11,7 90,0 188,0 24 19135 10 x2 x0,75 16,6 258,0 467,0 19
19109
14 x2 x0,25 12,7 111,2 220,0 24 19136
14 x2 x0,75 18,2 316,6 546,0 19
19119 1 x2 x0,5 5,7 22,0 47,0 20 19137 1 x2 x1 6,9 42,0 71,0 18
19120 2 x2 x0,5 8,2 50,0 100,0 20 19138 2 x2 x1 9,9 73,0 130,0 18
19121 3 x2 x0,5 8,8 71,8 131,0 20 19139 3 x2 x1 10,5 93,6 170,0 18
19122 4 x2 x0,5 9,6 74,4 149,0 20 19140 4 x2 x1 11,6 117,8 204,0 18
19123 5 x2 x0,5 10,6 84,5 169,0 20 19141 5 x2 x1 12,8 139,0 238,0 18
19124 6 x2 x0,5 11,5 99,6 196,0 20
19125 8 x2 x0,5 13,4 144,3 285,0 20
19126 10 x2 x0,5 14,9 176,0 344,0 20
19127 14 x2 x0,5 16,5 215,4 401,0 20
Dimensionsandspecificationsmaybechangedwithoutpriornotice.(RC03)
Cables for Drag Chains / Data-Cables for Drag Chains
Application
For decentralised installation and control technology. These cables are used in connector systems for sensors and actuators. In combination with
injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element between the periphery and the PLC
in production systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also
in the entire manufacturing industry. While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now
field bus technology has made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. Moving the
I/O points to the system periphery enables significant reductions in installation costs.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
SENSORFLEX-H (Li12Y11Y) sensor actuator cables, halogen-free, high flexible drag chain cable, PUR
Part no. Cable structure AWG-No.
black grey No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** approx. weight approx.
mm mm kg / km kg / km
76283 76299 2 x 0,25 PUR BN, BU X 4,4 4,8 22,0 24
76284 76300 3 x 0,25 PUR BN, BU, BK X 4,4 7,2 22,0 24
76285 76301 4 x 0,25 PUR BN, BU, BK, WH X 4,7 9,6 26,0 24
76286 76302 5 x 0,25 PUR BN, BU, BK, WH, GY X 4,8 12,0 30,0 24
76287 76303 2 x 0,34 PUR BN, BU X 4,9 6,5 30,0 22
76288 76304 3 x 0,34 PUR BN, BU, BK X 4,9 9,8 30,0 22
76289 76305 4 x 0,34 PUR BN, BU, BK, WH X 5,2 13,1 43,0 22
76290 76306 5 x 0,34 PUR BN, BU, BK, WH, GY X 5,9 16,4 54,0 22
78265 78266 5 G 0,34 PUR BN, BU, BK, WH, GN-YE X 5,9 16,4 54,0 22
76291 76307 2 x 0,5 PUR BN, BU X 5,0 9,6 40,0 20
78267 78268 3 G 0,5 PUR BK with number, GN-YE X 5,7 14,4 43,0 20
76292 76308 3 x 0,5 PUR BN, BU, BK X 5,0 14,4 40,0 20
76293 76309 4 x 0,5 PUR BN, BU, BK, WH X 5,5 19,2 47,0 20
76294 76310 5 x 0,5 PUR BN, BU, BK, WH, GY X 6,0 24,0 55,0 20
Continuation
192
Cables for Drag Chains / Data-Cables for Drag Chains
SENSORFLEX-H (Li9Y11Y) sensor actuator cables, halogen-free, high flexible drag chain cable, PUR
Part no. Cable structure AWG-No.
Sheath colour No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** approx. weight approx.
mm mm kg / km kg / km
75801 GY RAL 7001 3 x 0,25 PUR BN, BU, BK X 4,5 7,2 22,0 24
77468 GY RAL 7001 4 x 0,25 PUR BN, BU, BK, WH X 4,7 9,6 26,0 24
76705 GY RAL 7001 8 x 0,25 PUR DIN 47100 X 6,0 19,2 49,0 24
77427 GY RAL 7001 4 x 0,34 PUR BN, BU, BK, WH X 4,9 13,1 43,0 22
77428 GY RAL 7001 3 G 0,75 PUR BK with number, GN-YE X 6,2 21,6 54,0 18
78275 GY RAL 7001 3 x 0,75 PUR BK with number, GN-YE X 6,2 21,6 54,0 18
77429 GY RAL 7001 4 G 0,75 PUR BK with number, GN-YE X 6,2 28,8 66,0 18
193
MOTOR, SERVO, & FEEDBACK CABLES
3
in
E
VD eld 29
ng
x
xe
ex
VD
ed
U
R/ shi E 0
xi
- fi
- fl
./
0 /
le
ed
i
no
H A ed / VD
-f
-f
U
C)
C)
ge
us
us
CS REG
e n es /
(
e
lta
di
di
se
re
re
t
fre
ut tan
r
n
ra
ra
co
tu
tu
u
vo
E
ai
n-
or
sis
ra
ra
A
d
ch
al
ge
in
in
pe
pe
re
do
re
in
ge
nd
nd
ag
lo
lo
re
V-
m
L/
om
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
D
N
Motor, servo, and feedback cables
TOPFLEX 600-C-PVC
-15 to +80 -40 to +80 0.6/1 kV 7.5x 4x X 198
TOPFLEX 611-C-PUR
-30 to +80 -40 to +80 0.6/1 kV 10x 5x X X X X X 200
Feedback cable PUR -30 to +80 -40 to +80 250 10x 5x X X X X X 203
TOPFLEX - EMV-3 PLUS 2YSLCY-J +5 to +70 -40 to +70 0.6/1 kV 20x 10x X X 205
195
SELECTION TABLE - DRAG CHAIN CABLES
ng
in
xi
g
/s 2
ce
fle
in
/
an
ex
ge U
(m
-
es ist
lta 0 /
- fl
us
)
-c t d
vo U
/s
di
io
)
C)
g ge
en
(m
ra
at
or
(
tin lta
er
m
re
in
s
25
e
el
nt
ra vo
ee
le
ui CSA
ov
nd
tu
s
c
yc
)
al
to
le
sp
ac
pe l
ra
ia
m
O ina
be
ov
r
.c
up
va
te
eq L/
er
pe
.
ge
.
ax
ax
ou
pr
ax
ax
m
om
.
at
in
U
m
=
Ap
M
M
0
Pa
M
M
M
M
(D
(1
Te
N
PUR motor & servo cables for drag chains
TOPFLEX 611-PUR 30 7.5 x D 4 50 11 Mio PP/PUR 600/1000V -30 to +80 199 431
TOPFLEX 611 C-PUR
30 10 x D 4 50 11 Mio PP/CU/PUR 600/1000V -30 to +80 200 437
TOPSERV 110 30 7.5 x D 3 10 11 Mio PP/CU/PUR 600/1000V -30 to +80 201 468
TOPSERV 120 30 7.5 x D 3 10 11 Mio PP/CU/PUR 600/1000V -30 to +80 201 468
PUR feedback cables for drag chain cables
Tachofeedback-cable-C-PUR 30 10 x D 4 50 9 Mio PP/CU/PUR 450V -30 to +80 203 470
Incremental encoder cable C-PUR 30 10 x D 4 50 9 Mio PP/CU/PUR 250V -30 to +80 203 470
TOPFLEX-PUR 30 10 x D 4 50 9 Mio PP/CU/PUR 350V -30 to +80 203 470
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).
196
Motor-, Servo and Feedback Cables
D
Technical data Cable structure Properties
Special PVC-insulated sheathed cable Bare copper-conductor, to PVC outer sheath: extensively oil resistant
adapted to DIN VDE 0293, 0295 DIN VDE 0295 cl.5, fine-wire, Chemical Resistance - see table Technical
Temperature range IEC 60228 cl.5 Informations
flexing -15C to +80C Core insulation of PVC The materials used in manufacture are
fixed installation -40C to +80C Core identification to DIN VDE 0293 cadmium-free and contain no silicone
Nominal voltage U0/U 600/1000 V black cores with continuous white and free from substances harmful to
Test voltage 4000 V numbering the wetting properties of lacquers
Breakdown voltage GN-YE conductor Tests
min. 8000 V Cores stranded in layers with PVC self-extinguishing and flame retardant
Insulation resistance optimal lay-length acc. to DIN VDE 0482-332-1-2,
min. 20 MOhm x km Outer sheath of special PVC DIN EN 60332-1-2, IEC 60332-1 (equivalent
Minimum bending radius Sheath colour grey (RAL 7001) DIN VDE 0472 part 804 test method B)
flexing 7,5x cable with meter marking
fixed installation 4x cable Note
Radiation resistance For use in drag chains, we
up to 80x106 cJ/kg (to 80 Mrad) recommend our versions
TOPFLEX 611-PUR and
TOPFLEX 611-C-PUR
screened analogue type:
TOPFLEX 600-C-PVC, confer page 198
Application
As supply cable for electronically controlled servo-motors and connections to DNC motors. The cable is suitable for permanent and flexible installation
for medium mechanical loads in dry, damp and wet environments.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22860 4 G 1,5 9,6 58,0 130,0 16 22866 4 G 25 27,4 960,0 1805,0 4
22861 4 G 2,5 11,2 95,0 220,0 14 22867 4 G 35 30,0 1344,0 2060,0 2
22862 4G4 13,0 154,0 330,0 12 22868 4 G 50 35,8 1920,0 2900,0 1
22863 4G6 14,5 231,0 445,0 10 22869 4 G 70 40,9 2640,0 4050,0 2/0
22864 4 G 10 18,2 384,0 660,0 8 22854 4 G 95 46,2 3648,0 5540,0 3/0
22865 4 G 16 22,3 615,0 1060,0 6 22855 4 G 120 51,6 4608,0 7000,0 4/0
197
Motor-, Servo and Feedback Cables
Application
As supply cable for electronically controlled servo-motors and connections to DNC motors. The cable is suitable for permanent and flexible installation
for medium mechanical loads in dry, damp and wet environments.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22960 4 G 1,5 11,8 99,0 250,0 16 22966 4 G 25 31,7 1169,0 1920,0 4
22961 4 G 2,5 13,8 169,0 360,0 14 22967 4 G 35 34,5 1680,0 2515,0 2
22962 4G4 15,7 234,0 530,0 12 22856 4 G 50 40,7 2370,0 3315,0 1
22963 4G6 17,3 316,0 620,0 10 22857 4 G 70 46,0 3257,0 4600,0 2/0
22964 4 G 10 21,5 549,0 1050,0 8 22858 4 G 95 51,3 4060,0 6060,0 3/0
22965 4 G 16 26,1 807,0 1465,0 6 22859 4 G 120 56,4 5231,0 7315,0 4/0
198
Motor-, Servo and Feedback Cables
TOPFLEX 611-PUR motor power supply cable 0,6/1kV, cable for drag
chain, halogen-free, meter marking
D
Technical data Cable structure Properties
Special-PUR drag chain cable Bare copper-conductor, to Adhesion-free, extremely abrasion
adapted to DIN VDE 0293, 0295, 0250, DIN VDE 0295 cl.6, extra fine-wire, resistant, halogen-free, resistant to
DIN VDE 0285-525-1 / DIN EN 50525-1 BS 6360 cl.6, IEC 60228 cl.6 hydrolysis and microbial attack
Temperature range Core insualtion of PP resistant to UV-radiation,
flexing -30C to +80C Core identification to DIN VDE 0293 oxygen and ozone
fixed installation -40C to +80C black cores with continuous white The materials used in manufacture are
Nominal voltage U0/U 600/1000 V numbering cadmium-free and contain no silicone
Test voltage 4000 V GN-YE conductor and free from substances harmful to
Insulation resistance Cores stranded together with optimal the wetting properties of lacquers
min. 20 MOhm x km lay-length and stabilising filler
Min. bending radius Fleece wrapping facilitates sliding Note
flexing 7,5x cable Outer sheath of PUR G = with green-yellow conductor
fixed installation 4x cable Sheath colour grey (RAL 7001) For extreme applications extending beyond
with meter marking standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems.
Please observe applicable installation
regulations for use in energy supply chains.
screened analogue type:
TOPFLEX 611-C-PUR, confer page 200
Application
As optimized supply cable for the supply to motors, in particular to DNC motors, servo-motors. These cables are specially designed for use in power
drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. Optimised insulation materials ensure
resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents. Favourable outer diameters, reduced
weights and enhanced torsion characteristics assure the use in multi-layer operations with extremely high continuous bending loads. Suitable for
outdoor use.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22870 4 G 1,5 8,0 58,0 125,0 16 22876 4 G 25 26,9 960,0 1510,0 4
22871 4 G 2,5 10,8 95,0 215,0 14 22877 4 G 35 30,7 1344,0 2100,0 2
22872 4G4 12,5 154,0 310,0 12 22978 4 G 50 36,5 1920,0 2950,0 1
22873 4G6 14,8 231,0 470,0 10 22979 4 G 70 41,6 2640,0 4090,0 2/0
22874 4 G 10 18,8 384,0 760,0 8 22980 4 G 95 48,2 3648,0 5580,0 3/0
22875 4 G 16 22,8 615,0 1250,0 6 22981 4 G 120 51,6 4608,0 7040,0 4/0
199
Motor-, Servo and Feedback Cables
Application
As optimized supply cable for the supply to motors, in particular to DNC motors, servo-motors. These cables are specially designed for use in power
drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. Optimised insulation materials ensure
resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents. Favourable outer diameters, reduced
weights and enhanced torsion characteristics assure the use in multi-layer operations with extremely high continuous bending loads. Suitable for
outdoor use.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22970 4 G 1,5 11,3 99,0 220,0 16 22976 4 G 25 31,2 1169,0 1990,0 4
22971 4 G 2,5 13,5 169,0 340,0 14 22977 4 G 35 35,2 1680,0 2535,0 2
22972 4G4 16,0 234,0 490,0 12 22982 4 G 50 42,5 2370,0 3360,0 1
22973 4G6 17,8 316,0 680,0 10 22983 4 G 70 48,8 3257,0 4650,0 2/0
22974 4 G 10 22,2 549,0 1035,0 8 22984 4 G 95 54,6 4060,0 6090,0 3/0
22975 4 G 16 27,2 807,0 1460,0 6 22985 4 G 120 58,5 5231,0 7380,0 4/0
200
Motor-, Servo and Feedback Cables
TOPSERV 110 / 120 PUR servo cable with 1 or 2 signal pairs 0,6/1kV,
high flexible, cable for drag chain, EMC preferred type
D
Technical data Cable structure Properties
Spezial-PUR drag chain cable Bare copper-conductor, to low capacitance by using PP as core
adapted to DIN VDE 0295, 0250, DIN VDE 0295 cl.6, extra fine-wire insulation
DIN VDE 0285-525-1-1/DIN EN 50525-1 Core insulation of halogen-free PP PUR-outer sheath low adhesion,
Temperature range Core identification resistant to hydrolysis and microbial attack,
flexing -30C to +80C power supply cores halogen-free
fixed installation -40C to +80C core 1: black with imprint U/L1/C/L+ These highly flexible cables are fitted with
Nominal voltage core 2: black with imprint V/L2 an additional overall screen to assure EMC
power supply cores U0/U 600/1000 V core 3: black with imprint W/L3/D/L- compatibility, i.e. the protection against
control cores U0/U 300/500 V control cores electromagnetic interference
Test voltage TOPSERV 110 The materials used in manufacture are
power supply cores 4000 V core 1 black with imprint BR1 cadmium-free and contain no silicone
control cores 1000 V core 2 black with imprint BR2 and free from substances harmful to
Power rating TOPSERV 120 the wetting properties of lacquers
to DIN VDE 0298 part 4 pair 1: black with number no. 5+6
Insulation resistance pair 2: black with number no. 7+8 Note
min. 20 MOhm x km GN-YE conductor For extreme applications extending beyond
Minimum bending radius Screening of the control cores in pairs, standard solutions we recommend that
flexing 7,5x cable tinned drain wire and you request our questionnaire, which has
fixed installation 4x cable tinned Cu braid been especially designed for energy supply
Coupling resistance Control cores stranded in pairs and laid up in systems.
max. 250 Ohm/km layers together with the power supply cores Please observe applicable installation
Foil wrapping regulations for use in energy supply chains.
Overall screening of tinned cu braid, AWG sizes are approximate equivalent
visible coverage min. 80% values. The actual cross-section is in mm.
Fleece wrapping Servo-cable and Feedback-cable
Outer sheath of PUR with UL-approval to e.g. Siemens,
Sheath colour petrol (RAL 5018) Bosch Rexroth, Lenze etc. can be
found in chapter N ...
Application
The combination of feeder cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision servomotors,
as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting cables. These requirements
are met to a high degree as is the electromagnetic compatibillity (EMC). These cables can also be used as drag chain cables. Manufacturing is based
on specifications from renowned manufacturers of servo-actuators and servo-controls as well as in accordance with diverse VDE standards. Application
for system SIMODRIVE.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPSERV 110 (1 pair screened and overall screening) TOPSERV 120 (2 pairs individually screened and overall
Part no. No.cores x Outer Cop. Weight AWG-No. screening)
cross-sec. approx. weight approx. Part no. No.cores x Outer Cop. Weight AWG-No.
mm mm kg / km kg / km cross-sec. approx. weight approx.
71491 ( 4 G 1,5 + (2 x 1,0)) 11,5 139,0 211,0 16 mm mm kg / km kg / km
71493 ( 4 G 2,5 + (2 x 1,0)) 13,6 188,0 273,0 14 71990 ( 4 G 1,5 + 2 x (2 x 1,0)) 12,6 186,0 242,0 16
71705 ( 4 G 4 + (2 x 1,0)) 14,6 260,0 352,0 12 71991 ( 4 G 2,5 + 2 x (2 x 1,0)) 15,0 231,0 316,0 14
71706 ( 4 G 6 + (2 x 1,0)) 16,0 360,0 500,0 10 71992 ( 4 G 4 + 2 x (2 x 1,0)) 16,0 308,0 415,0 12
71707 ( 4 G 10 + (2 x 1,0)) 20,2 590,0 753,0 8 71993 ( 4 G 6 + 2 x (2 x 1,0)) 18,2 420,0 574,0 10
71708 ( 4 G 16 + (2 x 1,0)) 23,8 845,0 1061,0 6 71994 ( 4 G 10 + 2 x (2 x 1,0)) 22,8 647,0 805,0 8
71709 ( 4 G 25 + (2 x 1,0)) 27,0 1320,0 1499,0 4 71995 ( 4 G 16 + 2 x (2 x 1,0)) 25,0 918,0 1122,0 6
71710 ( 4 G 35 + (2 x 1,0)) 31,9 1840,0 1992,0 2 71996 ( 4 G 25 + 2 x (2 x 1,0)) 27,7 1400,0 1584,0 4
71711 ( 4 G 50 + (2 x 1,0)) 36,7 2530,0 2880,0 1 72106 ( 4 G 35 + 2 x (2 x 1,0)) 32,0 1882,0 2185,0 2
71997 ( 4 G 50 + 2 x (2 x 1,0)) 37,0 2574,0 2977,0 1
Dimensions and specifications may be changed without prior notice. (RD01)
201
Motor-, Servo and Feedback Cables
Application
These feedback cables are used in machinery and control construction as well as in plant engineering as these enable an excellent transmission of data
and signals. Additional cores for the power supply to individual components are available.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX-PVC
Part No.cores x Core Core Sheath Outer Cop. Weight AWG-No.
no. cross-sec. marking marking colour approx. mm weight approx.
mm 0,14 mm 0,5 mm kg / km kg / km
22800 ( 3 x (2 x 0,14) + (2 x 0,5)) GN+YE, GY+PK, BU+RD WH, BN Grey 8,5 78,0 112,0 26
22806 ( 4 x 2 x 0,14 + 4 x 0,5) RD+BK, BN+GN, YE+VT, GN+PK WH, BU, WH/GN, BN/GN Grey 8,5 68,0 111,0 26
22845 ( 10 x 0,14 + 2 x 0,5) DIN 47100 WH, BN Grey 8,0 46,2 70,0 26
22846 ( 10 x 0,14 + 4 x 0,5) DIN 47100 WH, BN, GN, YE Grey 8,2 56,3 86,0 26
Incremental feedback-cable
Part No.cores x Core Core Sheath Outer Cop. Weight AWG-No.
no. cross-sec. marking marking colour approx. mm weight approx.
mm 0,25 mm 1 mm kg / km kg / km
22825 ( 4 x 2 x 0,25 + 2 x 1,0) BN+GN, RD+BK, VT+BU, GY+PK WH, BN Grey 8,8 66,0 110,0 24
202
Motor-, Servo and Feedback Cables
Feedback cables PUR high flexible feedback cables for drag chain,
EMC-preferred type, meter marking
D
Technical data Cable structure Properties
Temperature range Bare copper-conductor, to Special PUR outer sheath low adhesion
flexing -30C to +80C DIN VDE 0295 cl.6, extra fine-wire, Resistant to
fixed installation -40C to +80C BS 6360 cl.6, IEC 60228 cl.6 Oils and fats
Nominal voltage Core insualtion of PP Acids and alkalis
TOPFLEX-PUR 350 V Part No. 22847 Cu-screen of single pairs Hydraulic fluids
Tachofeedback-cable-C-PUR 450 V or single cores and PETP (polyethylene Oxygen and ozone
Incremental Feedback-cable-C-PUR 250 V terephthalate) sheath UV-radiation
Test voltage Core identification see table below Hydrolysis
core/core 2000 V Single cores or pairs stranded Microbial attack
core/screen 1000 V in layer with optimal lay-length Water and weathering effects
Insulation resistance (pairs part no. 22818) The high abrasion resistance and notch
min. 20 MOhm x km Drain wire resistance meet the highest requirements
Minimum bending radius Tinned copper braided screen, The materials used in manufacture are
flexing 10x cable approx. 85% coverage cadmium-free and contain no silicone
fixed installation 5x cable Outer sheath of special PUR, matt and free from substances harmful to
Coupling resistance Sheath colour see table below the wetting properties of lacquers
max. 250 Ohm/km
Radiation resistance Note
up to 100x106 cJ/kg (up to 100 Mrad) For extreme applications extending beyond
standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems.
Please observe the assembly instruction
for use in energy supply chains.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
Both cables fulfil different tasks for the control of servo-motors. The tachofeedback-cable or response cable serves the regulation of the motor speed
and measurement of the actual values. The incremental feedback-cable or position response cable transfers the control signals for positioning and
engineering characteristics and is used as the flexible connecting cable for tachometer, brakes and pulse transmitter in case of high mechanical stress
in plant, machine and control engineering in dry, moist and wet rooms. Particularly suitable for continuous operating in drag chains, industrial robotics
and handling equipment as these cables enable an excellent transmission of data and signals. Additional cores for the power supply to individual
components are available. The braided screen guarantees reliable signal transmission. Optimum functionality, long service life and an excellent
cost-performance ratio are given for the mentioned applications by the special compounds used for insulation and sheath.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX-PUR
Part No.cores x Core Core Sheath Outer Cop. Weight AWG-No.
no. cross-sec. marking marking colour approx. mm weight approx.
mm 0,14 mm 0,5 mm kg / km kg / km
22847 ( 3 x (2 x 0,14) + (2 x 0,5)) DIN 47100 WH, BN Grey 8,3 78,0 103,0 26
22852 4 x 2 x 0,14 + 4 x 0,5 BN+GN, YE+VT, GY+PK, RD+BU WH, BN, WH/GN, BN/GN Grey 8,4 73,0 105,0 26
22849 ( 10 x 0,14 + 2 x 0,5) DIN 47100 WH, BN Grey 7,2 39,0 83,0 26
Tachofeedback-cable
Part No.cores x Core Core Sheath Outer Cop. Weight AWG-No.
no. cross-sec. marking marking colour approx. mm weight approx.
mm 0,5 mm - kg / km kg / km
22823 ( 9 x 0,5) WH, BN, GN, YE, GY, PK, BU, RD, BK - Orange 8,8 80,8 128,0 20
203
Motor-, Servo and Feedback Cables
Application
This TOPFLEX-EMV-2YSLCY-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings,
facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a
supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments, not
however for outdoor applications. Used in the automotive and food industries, environmental technology, packaging industry, machine tools. Handling
equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations
and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight approx.
mm approx.nF / approx.nF / Ohm/km Ohm/km in Amperes kg / km kg / km
km km
22084 4 G 1,5 10,1 70 110 18 95,0 230,0 16
22085 4 G 2,5 11,9 80 130 18 210 26 150,0 300,0 14
22086 4G4 13,6 90 150 11 210 34 235,0 485,0 12
22087 4G6 15,3 90 150 6 150 44 320,0 633,0 10
22088 4 G 10 19,4 120 200 7 180 61 533,0 863,0 8
22089 4 G 16 22,4 140 230 9 190 82 789,0 1291,0 6
22090 4 G 25 26,7 120 210 4 95 108 1236,0 1862,0 4
22091 4 G 35 29,3 150 260 3 85 135 1662,0 2611,0 2
22092 4 G 50 34,1 190 320 2 40 168 2345,0 2955,0 1
22093 4 G 70 39,0 190 320 2 45 207 3196,0 3953,0 2/0
22094 4 G 95 44,0 250 410 1 50 250 4316,0 5304,0 3/0
22095 4 G 120 48,7 292 5435,0 6604,0 4/0
22096 4 G 150 54,2 335 6394,0 7043,0 300 kcmil
22097 4 G 185 60,6 382 7639,0 8384,0 350 kcmil
204
Motor-, Servo and Feedback Cables
D
Technical data Cable structure Properties
Special motor power supply cable for Bare copper-conductor, to Low mutual capacitance
frequency converters adapted to DIN VDE 0295 cl.5, fine-wire, Low coupling resistance for high
DIN VDE 0250 BS 6360 cl.5, IEC 60228 cl.5 electromagnetic compatibility
Temperature range Core insulation of polyethylene (PE) The minimum cross-section
flexing +5C to +70C Core identification BK, BN, GY of 0,75 meets the requirements
fixed installation -40C to +70C GN-YE conductor (divided into 3) of DIN EN 60204 part 1.
Nominal voltage U0/U 600/1000 V 3+3-core structure The 3 PLUS-construction of motor power
Max. operating voltage Cores stranded in concentric layers supply cables features a symmetrical 3-core
A.C. and 3-phase 700/1200 V 1. Screen with special aluminium film design, improved in terms of EMC
DC operation 900/1800 V 2. Tinned copper braided screen, characteristics comparing favorably with a
Test voltage 4000 V approx. 85% coverage 4-core version. The protective conductor
Insulation resistance Outer sheath of special PVC PE, divided into 3 is uniformly stranded in
min. 200 MOhm x km Sheath colour transparent the interstices. This enables an extremely
Coupling resistance with meter marking concentric structure.
acc. to different cross-sections Due to the optimal screening an
max. 250 Ohm/km Note interference-free operation of
Minimum bending radius **)The current carrying capacity for frequency converters is obtained
free-movement for outer : permanent operation at ambient temperature The materials used in manufacture are
up to 12 mm: 10x cable of 30C. For deviating ambient temperatures cadmium-free and contain no silicone
> 12-20 mm: 15x cable the conversion factors should be used and and free from substances harmful to
> 20 mm: 20x cable for further see the indication in the wetting properties of lacquers
fixed installation for outer : DIN VDE 0298 part 4. Tests
up to 12 mm: 5x cable AWG sizes are approximate equivalent PVC self-extinguishing and flame retardant
> 12-20 mm: 7,5x cable values. The actual cross-section is in mm. acc. to DIN VDE 0482-332-1-2,
> 20 mm: 10x cable DIN EN 60332-1-2, IEC 60332-1 (equivalent
Radiation-resistance DIN VDE 0472 part 804 test method B)
up to 80x106 cJ/kg (up to 80 Mrad) Meets EMC requirements acc. to
EN 55011 and DIN VDE 0875 part 11
Application
As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments
not however for outdoor applications. Used in the automotive and food industries, environmental technology, packaging industry, machine tools.
Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning
installations and similar applications. Installation in hazardous areas. This screened motor supply cable with low mutual capacitance of the single cores
because of the special PE core insulation and low screen capacitance enable a low-loss transmission of the power compared to PVC-sheathed connecting
cables. Due to the optimal screening an interference-free operation of frequency converters is obtained. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm at 1 MHz at 30 MHz with 3 loaded cores weight approx. kg / km
mm Ohm/km Ohm/km in Amperes kg / km
22368 3 x 1,5 + 3 G 0,25 9,2 18 86,0 140,0 16
22369 3 x 2,5 + 3 G 0,5 10,8 18 210 26 144,0 220,0 14
22370 3 x 4 + 3 G 0,75 12,3 11 210 34 224,0 323,0 12
22371 3 x 6 + 3 G 1,0 14,0 6 150 44 298,0 420,0 10
22372 3 x 10 + 3 G 1,5 17,6 7 180 61 491,0 615,0 8
22373 3 x 16 + 3 G 2,5 21,2 9 190 82 723,0 819,0 6
22374 3 x 25 + 3 G 4,0 24,5 4 95 108 1138,0 1325,0 4
22375 3 x 35 + 3 G 6,0 26,9 3 85 135 1535,0 1718,0 2
22376 3 x 50 + 3 G 10,0 32,5 2 40 168 2208,0 2399,0 1
22377 3 x 70 + 3 G 10,0 35,5 2 45 207 2871,0 3056,0 2/0
22378 3 x 95 + 3 G 16,0 40,1 1 50 250 3953,0 4162,0 3/0
22379 3 x 120 + 3 G 16,0 44,4 292 4836,0 5074,0 4/0
22380 3 x 150 + 3 G 25,0 49,3 335 5412,0 6128,0 300 kcmil
22381 3 x 185 + 3 G 35,0 55,1 382 6969,0 7189,0 350 kcmil
22382 3 x 240 + 3 G 42,5 60,0 453 8540,0 9540,0 500 kcmil
205
Motor-, Servo and Feedback Cables
Application
This TOPFLEX-EMV-2YSLCYK-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings,
facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a
supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments and for
outdoor applications, possible for installation in underground at 4G16 mm. Used in the automotive and food industries, environmental technology,
packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators,
conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight approx.
mm approx.nF / approx.nF / Ohm/km Ohm/km in Amperes kg / km kg / km
km km
22234 4 G 1,5 10,1 70 110 18 95,0 230,0 16
22235 4 G 2,5 11,9 80 130 18 210 26 150,0 300,0 14
22236 4G4 13,6 90 150 11 210 34 235,0 485,0 12
22237 4G6 15,3 90 150 6 150 44 320,0 630,0 10
22238 4 G 10 19,4 120 200 7 180 61 533,0 860,0 8
22239 4 G 16 22,4 140 230 9 190 82 789,0 1290,0 6
22240 4 G 25 26,7 120 210 4 95 108 1236,0 1860,0 4
22241 4 G 35 29,3 150 260 3 85 135 1662,0 2610,0 2
22242 4 G 50 34,1 190 320 2 40 168 2345,0 2950,0 1
22243 4 G 70 39,0 190 320 2 45 207 3196,0 3950,0 2/0
22244 4 G 95 44,0 250 410 1 50 250 4316,0 5300,0 3/0
22245 4 G 120 48,7 292 5435,0 6600,0 4/0
22246 4 G 150 54,2 335 6394,0 7040,0 300 kcmil
22247 4 G 185 60,6 382 7639,0 8380,0 350 kcmil
206
Motor-, Servo and Feedback Cables
D
Technical data Cable structure Properties
Special motor power supply cable for Bare copper-conductor, to Low mutual capacitance
frequency converters adapted to DIN VDE 0295 cl.5, fine-wire, Low coupling resistance for high
DIN VDE 0250 BS 6360 cl.5, IEC 60228 cl.5 electromagnetic compatibility
Temperature range Core insulation of polyethylene (PE) Due to the optimal screening an
flexing -5C up to +70C Core identification BK, BN, GY interference-free operation of
fixed installation -40C up to +70C GN-YE conductor (divided into 3) frequency converters is obtained
Nominal voltage U0/U 600/1000 V 3+3 core design The 3 PLUS-construction of motor power
Max. operating voltage Cores stranded in concentric layers supply cables features a symmetrical 3-core
A.C. and 3-phase 700/1200 V 1. Screen with special aluminium film design, improved in terms of EMC
DC operation 900/1800 V 2. Tinned copper braided screen, characteristics comparing favorably with a
Test voltage 4000 V approx. 85% coverage 4-core version. The protective conductor
Insulation resistance Outer sheath of special PVC PE, divided into 3 is uniformly stranded in
min. 200 MOhm x km Sheath colour black (RAL 9005) the interstices. This enables an extremely
Coupling resistance with meter marking concentric structure
acc. to different cross-sections The minimum cross-section of
max. 250 Ohm/km Note 0,75 mm meets the requirements
Minimum bending radius **)The current carrying capacity for of DIN EN 60204 part 1
free-movement for outer : permanent operation at ambient temperature UV-resistant
up to 12 mm: 10x cable of 30C. For deviating ambient temperatures Outdoor application
> 12-20 mm: 15x cable the conversion factors should be used and This screened motor supply cable with
> 20 mm: 20x cable for further see the indication in low mutual capacitance of the single cores
fixed installation for outer : DIN VDE 0298 part 4. because of the special PE core insulation
up to 12 mm: 5x cable AWG sizes are approximate equivalent and low screen capacitance enable a low-loss
> 12-20 mm: 7,5x cable values. The actual cross-section is in mm. transmission of the power compared to
> 20 mm: 10x cable PVC-sheathed connecting cables
Radiation resistance The materials used in manufacture are
up to 80x106 cJ/kg (up to 80 Mrad) cadmium-free and contain no silicone
and free from substances harmful to
the wetting properties of lacquers
Tests
PVC self-extinguishing and flame retardant
acc. to DIN VDE 0482-332-1-2,
DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Meets EMC requirements acc. to
EN 55011 and DIN VDE 0875 part 11
Application
As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments
and for outdoor applications, possible for installation in underground at 3x16+3G2,5 mm. Used in the automobile industry, food industry, environmental
engineering, packaging industry, toolmaking machinery, handling equipment, for SIMOVERT drivers, they are particularly suitable for use with industrial
pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
207
Motor-, Servo and Feedback Cables
208
Motor-, Servo and Feedback Cables
D
Technical data Cable structure Properties
Special motor power supply cable for Bare copper-conductor, to Low mutual capacitance
frequency converters adapted to DIN VDE 0295 cl.5, fine-wire, Low coupling resistance for high
DIN VDE 0250 BS 6360 cl.5, IEC 60228 cl.5 electromagnetic compatibility
Temperature range Core insulation of cross-linked UV-resitant
flexing -5C to +90C polyethylene (XLPE) Outdoor application, possible for
fixed installation -40C to +90C Core identification BN, BK, GY installation in underground at 4G16 mm
Permissible operating temperature GN-YE conductor This screened motor supply cable with
at conductor +90C Cores stranded in concentric layers low mutual capacitance of the single cores
Nominal voltage U0/U 600/1000 V 1. Screen with special aluminium film because of the special XLPE core insulation
Max. operating voltage 2. Tinned copper braided screen, and low screen capacitance enable a low-loss
A.C. and 3-phase 700/1200 V approx. 85% coverage transmission of the power compared to
DC operation 900/1800 V Outer sheath of special PVC PE-sheathed connecting cables
Test voltage 4000 V Sheath colour black (RAL 9005) Due to the optimal screening an
Insulation resistance with meter marking interference-free operation of
min. 200 MOhm x km frequency converters is obtained
Coupling resistance Note The materials used in manufacture are
acc. to different cross-sections **)The current carrying capacity for cadmium-free and contain no silicone
max. 250 Ohm/km permanent operation at ambient temperature and free from substances harmful to
Minimum bending radius of 30C. For deviating ambient temperatures the wetting properties of lacquers
free-movement for outer : the conversion factors should be used and Tests
up to 12 mm: 10x cable for further see the indication in self-extinguishing and flame retardant
> 12-20 mm: 15x cable DIN VDE 0298 part 4. acc. to DIN VDE 0482-332-1-2,
> 20 mm: 20x cable AWG sizes are approximate equivalent DIN EN 60332-1-2, IEC 60332-1 (equivalent
fixed installation for outer : values. The actual cross-section is in mm. DIN VDE 0472 part 804 test method B)
up to 12 mm: 5x cable Meets EMC requirements acc. to
> 12-20 mm: 7,5x cable EN 55011 and DIN VDE 0875 part 11
> 20 mm: 10x cable
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Application
This TOPFLEX-EMV-UV-2XSLCYK-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and
buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings.
Respecting the permissible operating temperature at the conductor of +90 C permits a higher current carrying capacity than PE insulated power
distribution cables. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and
wet environments and for outdoor applications, possible for installation in underground at 4G16 mm. Used in the automotive and food industries,
environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with
industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. approx. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight approx.
mm approx.nF / approx.nF / Ohm/km Ohm/km in Amperes kg / km kg / km
km km
24489 4 G 1,5 10,1 70 110 23 95,0 230,0 16
24490 4 G 2,5 11,2 80 130 18 210 32 150,0 300,0 14
24491 4G4 12,8 90 150 11 210 42 235,0 485,0 12
24492 4G6 14,9 90 150 6 150 54 320,0 630,0 10
24493 4 G 10 17,7 120 200 7 180 75 533,0 860,0 8
24494 4 G 16 20,9 140 230 9 190 100 789,0 1290,0 6
Continuation
209
Motor-, Servo and Feedback Cables
210
Motor-, Servo and Feedback Cables
Application
As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments
and for outdoor applications, possible for installation in underground at 3x16+3G2,5 mm. Respecting the permissible operating temperature at the
conductor of +90 C permits a higher current carrying capacity than PE insulated power distribution cables. Used in the automobile industry, food
industry, environmental engineering, packaging industry, toolmaking machinery, handling equipment, for SIMOVERT drivers, they are particularly
suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous
areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
211
Motor-, Servo and Feedback Cables
212
Motor-, Servo and Feedback Cables
D
Technical data Cable structure Properties
Special motor power supply cable for Bare copper, fine wire conductor to halogen-free
frequency converters adapted to DIN VDE 0295 cl.5, BS 6360 cl.5, Low mutual capacitance
DIN VDE 0250 IEC 60228 cl.5 Low coupling resistance for high
Temperature range Core insulation of cross-linked electromagnetic compatibility
flexing -5C to +90C polyethylene (XLPE) This screened motor supply cable with
fixed installation -40C to +90C Core cidentification: BN, BL, GY low mutual capacitance of the single cores
Permissible operating temperature GN-YE conductor because of the special XLPE core insulation
at conductor +90C Cores stranded in concentric layers and low screen capacitance enable a low-loss
Nominal voltage U0/U 600/1000 V 1. Screen with special aluminium film transmission of the power compared to
Max. operating voltage 2. Tinned copper braided screen, PE-sheathed connecting cables
A.C. and 3-phase 700/1200 V approx. 85% coverage Due to the optimal screening an
DC operation 900/1800 V Outer sheath of special polyolefin compound interference-free operation of frequency
Test voltage 4000 V Sheath colour black (RAL 9005) converters is obtained
Insulation resistance with meter marking The materials used in manufacture are
min. 200 MOhm x km cadmium-free and contain no silicone
Coupling resistance Note and free from substances harmful to
acc. to different cross-sections The current carrying capacity for
**) the wetting properties of lacquers
max. 250 Ohm/km permanent operation at ambient temperature Tests
Minimum bending radius of 30C. For deviating ambient temperatures self-extinguishing and flame retardant
free-movement for outer : the conversion factors should be used and acc. to DIN VDE 0482-332-1-2,
up to 12 mm: 10x cable for further see the indication in DIN EN 60332-1-2, IEC 60332-1 (equivalent
> 12-20 mm: 15x cable DIN VDE 0298 part 4. DIN VDE 0472 part 804 test method B)
> 20 mm: 20x cable AWG sizes are approximate equivalent Meets EMC requirements acc. to
fixed installation for outer : values. The actual cross-section is in mm. EN 55011 and DIN VDE 0875 part 11
up to 12 mm: 5x cable
> 12-20 mm: 7,5x cable
> 20 mm: 10x cable
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Application
This TOPFLEX-EMV-UV-2XSLCH-J motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and
buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings.
Respecting the permissible operating temperature at the conductor of +90 C permits a higher current carrying capacity than PE insulated power
distribution cables. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and
wet environments. These cables are suitable for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit
all precautions must be taken that no accumulation of water can occur in the pipes. Used in the automotive and food industries, environmental
technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps,
ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
213
Motor-, Servo and Feedback Cables
214
Motor-, Servo and Feedback Cables
Application
As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments.
These cables are suitable for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must
be taken that no accumulation of water can occur in the pipes. Respecting the permissible operating temperature at the conductor of +90 C permits
a higher current carrying capacity than PE insulated power distribution cables. Used in the automobile industry, food industry, environmental engineering,
packaging industry, toolmaking machinery, handling equipment, for SIMOVERT drivers, they are particularly suitable for use with industrial pumps,
ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
215
Motor-, Servo and Feedback Cables
216
Motor-, Servo and Feedback Cables
TOPFLEX Motor 109 low capacitance power supply cable 0,6/1kV, increased
ampacity, halogen-free, meter marking
D
Technical data Cable structure Properties
Special motor power supply cable for Bare copper-conductor, to Special polymerinsulation ensures low
frequency converters DIN VDE 0295 cl.5, fine-wire, dielectric losses, a dual voltage resistance,
Temperature range BS 6360 cl.5, IEC 60228 cl.5 longer service life and low - interference
flexing -5C to +70C Core insualtion of special Polymer shield, and increased current carrying
fixed installation -40C to +80C Core identification to DIN VDE 0293-308 capacity
Permissible operating temperature - up to 5 cores coloured Low coupling resistance for high
at conductor +90C - from 7 cores, black with continuous electromagnetic compatibility
Nominal voltage U0/U 600/1000 V white numbering UV-resistant
Max. operating voltage GN-YE conductor Outdoor application
A.C. and 3-phase 700/1200 V Cores stranded in concentric layers This screened motor supply cable with
DC operation 900/1800 V 1. Screen with special aluminium film low mutual capacitance of the single
Test voltage 2500 V 2. Tinned copper braided screen, cores because of the special Polymer
Insulation resistance approx. 80% coverage core insulation and low screen capacitance
min. 200 MOhm x km Outer sheath of special PUR enable a low-loss transmission of the
Coupling resistance Sheath colour orange (RAL 2003) power compared to PVC-sheathed
acc. to different cross-sections with meter marking connecting cables
max. 250 Ohm/km Due to the optimal screening an
Mutual capacitance interference-free operation of frequency
acc. to different cross-sections converters is obtained
core/core 70 to 250 nF/km Design acc. to the requirements of
core/screen 110 to 410 nF/km VdS 3501:2006-04
Minimum bending radius The materials used in manufacture are
free-movement for outer : cadmium-free and contain no silicone
up to 12 mm: 10x cable and free from substances harmful to
> 12-20 mm: 15x cable the wetting properties of lacquers
> 20 mm: 20x cable Tests
fixed installation for outer : Low mutual capacitance, test acc. to
up to 12 mm: 5x cable DIN VDE 0472 part 504, test method B
> 12-20 mm: 7,5x cable Meets EMC requirements acc. to
> 20 mm: 10x cable EN 55011 and DIN VDE 0875 part 11
Radiation-resistance
up to 80x106 cJ/kg (up to 80 Mrad) Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
This motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings, facilities with units and
operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a supply and connecting
cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments and for outdoor applications.
Used in the automotive and food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives,
they are particularly suitable for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
22724 3 G 1,5 9,4 72,0 200,0 16 22715 5G4 15,4 321,0 567,0 12
22707 4 G 1,5 10,4 95,0 230,0 16 22716 7G4 18,2 352,0 603,0 12
22708 5 G 1,5 11,2 117,0 258,0 16 22717 4G6 15,2 320,0 633,0 10
22709 7 G 1,5 13,2 148,0 281,0 16 22718 5G6 16,8 439,0 679,0 10
22710 3 G 2,5 11,2 137,0 270,0 14 22719 7G6 20,0 501,0 771,0 10
22711 4 G 2,5 12,5 150,0 300,0 14 22720 4 G 10 19,5 533,0 860,0 8
22712 5 G 2,5 13,5 200,0 352,0 14 22721 5 G 10 21,6 711,0 1029,0 8
22713 7 G 2,5 16,0 230,0 473,0 14 22722 4 G 16 23,1 789,0 1290,0 6
22714 4G4 14,2 235,0 485,0 12 22723 4 G 25 27,1 1236,0 1862,0 4
217
HEAT-RESISTANT CABLES
3
in
E
VD eld 29
ng
x
xe
ex
VD
ed
U
R/ shi E 0
xi
- fi
- fl
./
0 /
le
ed
i
no
H A ed / VD
-f
-f
U
C)
C)
ge
us
us
CS REG
e n es /
(
e
lta
di
di
se
re
re
t
fre
ut tan
r
n
ra
ra
co
tu
tu
u
vo
E
ai
n-
or
sis
ra
ra
A
d
ch
al
ge
in
in
pe
pe
re
do
re
in
ge
nd
nd
ag
lo
lo
re
V-
m
L/
om
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
N
Heat-resistant cables
THERMFLEX 180 EWKF -25 to +180 -60 to +180 300/500 7.5x 4x X X X 225
THERMFLEX 180 EWKF-C -25 to +180 -60 to +180 300/500 10x 5x X X X X 234
219
Heat resistant Cables
Application
Therm cables are ideal for use in machines, appliances or motors which are subject to direct contact with high temperatures (e. g. varnishing machines
and drying towers etc.). For application in dry, moist and wet rooms and in open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24002 2 x 0,5 5,0 9,6 40,0 20 24030 2 x 1,5 7,4 29,0 77,0 16
24003 3 G 0,5 5,3 14,4 50,0 20 24031 3 G 1,5 8,1 43,0 97,0 16
24004 4 G 0,5 5,8 19,2 60,0 20 24032 4 G 1,5 9,0 58,0 122,0 16
24005 5 G 0,5 6,7 24,0 70,0 20 24033 5 G 1,5 10,0 72,0 143,0 16
24006 7 G 0,5 8,8 33,6 90,0 20 24034 7 G 1,5 11,9 101,0 179,0 16
24007 12 G 0,5 11,1 58,0 140,0 20 24035 12 G 1,5 14,5 173,0 310,0 16
24008 18 G 0,5 12,9 86,0 170,0 20 24036 18 G 1,5 17,4 259,0 460,0 16
24009 25 G 0,5 15,8 101,0 250,0 20 24037 25 G 1,5 21,3 360,0 650,0 16
24011 2 x 0,75 6,2 14,4 52,0 19 24039 2 x 2,5 9,3 48,0 120,0 14
24012 3 G 0,75 6,6 21,6 61,0 19 24046 3 G 2,5 10,1 72,0 150,0 14
24013 4 G 0,75 7,1 29,0 75,0 19 24040 4 G 2,5 11,0 96,0 200,0 14
24014 5 G 0,75 8,0 36,0 94,0 19 24041 5 G 2,5 12,3 120,0 250,0 14
24015 7 G 0,75 9,5 50,0 112,0 19 24042 7 G 2,5 14,6 168,0 310,0 14
24016 12 G 0,75 11,6 86,0 180,0 19 24044 2x4 10,6 77,0 180,0 12
24017 18 G 0,75 13,9 130,0 270,0 19 24291 3G4 11,5 115,0 220,0 12
24018 25 G 0,75 16,9 180,0 380,0 19 24045 4G4 12,5 154,0 300,0 12
24019 1x1 6,0 9,6 50,0 18 24292 5G4 15,1 192,0 360,0 12
24020 2x1 6,5 19,2 60,0 18
24021 3G1 6,9 29,0 73,0 18
24022 4G1 7,7 38,0 88,0 18
24023 5G1 8,4 48,0 110,0 18
24024 6G1 9,3 58,0 121,0 18
24025 7G1 10,0 67,0 130,0 18
24026 12 G 1 12,5 115,0 223,0 18
24027 18 G 1 14,7 173,0 350,0 18
24028 25 G 1 17,8 240,0 485,0 18
220
Heat resistant Cables
Technical data
Halogen-free control and connecting cable
Cable structure
Tinned Cu wires, acc. to
Properties
Reduced flame propagation
E
with increased heat resistance DIN VDE 0295 cl.5, BS 6360 cl.5 Good abrasion and notch resistance
Temperature range and IEC 60228 cl. 5 Good resistance to oils and weathering
flexing -35C to +120C Core insulation of halogen-free, Resistant to UV radiation and ozone
fixed installation -55C to +145C cross-linked polyolefin-copolymer Resistant to soldering temperatures
in short-circuit +250C Core identification to DIN VDE 0293-308 Thermal class B
Nominal voltage - for 2 cores BN, BU Are resistant to melting, even when in
up to 1,0 mm U0/U 300/500 V - up to 5 cores coloured contact with a soldering iron at
from 1,5 mm U0/U 450/750 V - from 6 cores, black with continuous temperatures of between 300C and
with protected fixed installation white numbering 380C, because of the cross-linking for
from 1,5 mm U0/U 600/1000 V also available in other colours on request the insulation material
Test voltage 3000 V GN-YE conductor, 3 cores and above The materials used in manufacture are
Minimum bending radius Cores stranded in layers with cadmium-free and contain no silicone
in operation 8x cable optimal lay-length and free from substances harmful to
fixed installation 4x cable Fleece wrapping the wetting properties of lacquers
Caloric load values Outer sheath of halogenfree, Tests
see Technical Informations cross-linked Polyolefin-Copolymer Flame test (unit flame test) acc. to
Power ratings table Sheath colour black DIN VDE 0482-332-3-22, BS 4066 part 3,
see Technical Informations also available in other colours on request DIN EN 60332-3-22, IEC 60332-3-22
Approval with meter marking (previously DIN VDE 0472
Germanischer Lloyd part 804 test method C)
Note Flame test (cable) acc. to
G = with green-yellow conductor DIN VDE 0482-332-1-2, DIN EN 60332-1-2,
x = without green-yellow conductor IEC 60332-1-2 (equivalent DIN VDE 0472
AWG sizes are approximate equivalent part 804 test method B)
values. The actual cross-section is in mm. Corrosiveness of combustion gases
screened analogue type: acc. to DIN VDE 0482 part 267,
HELUTHERM 145 MULTI-C, DIN EN 50267-2-2, IEC 60754-2
confer page 230 (equivalent DIN VDE 0472 part 813)
Halogen-free
acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-1, IEC 60754-1
(equivalent DIN VDE 0472 part 815)
Smoke density
acc. to DIN VDE 0482 part 1034-1+2,
DIN EN 61034-1+2, IEC 61034-1+2,
BS 7622 part 1+2
(previously DIN VDE 0472 part 816)
Application
These halogen-free, cross-linked and temperature resistant wiring and control cables with enhanced fire-behaviour properties are used for wiring up
the lighting fixtures, heaters, electric machines (temperature class B), switching systems and distribution switchboards. A very long service life is also
given on account of their excellent high-temperature stability. These cables exhibit good resistance to weathering as well as being very stable to
temperature, moisture, ozone and UV radiation. These cables are therefore mainly used for traffic control systems and diverse outdoor applications.
The development of smoke is low and no corrosive gases are liberated during combustion of these halogen-free cables in case of fire. The risk of toxic
fumes is considerably less in the event of fire because the coloric load values is lower. Precious time can thus be won for a disciplined evacuation, and
unnecessary loss of life can be prevented. The extent of the damage to costly control and monitoring systems and the concrete and steel structures
of buildings and plant due to fire is reduced by this. Injuries to persons and damage to materials can be prevented. A lower conductor cross-section
is possible in certain circumstances because of the high thermal load and thus savings in the space and weight required can be made. These wiring
and control cables provide a significant contribution in safety engineering and environmental protection.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
53376 1 x 0,25 2,9 2,4 11,4 24 53381 6 G 0,25 6,5 14,4 58,0 24
52630 1 G 0,25 2,9 2,4 11,4 24 53382 7 G 0,25 6,9 16,8 64,0 24
53377 2 x 0,25 4,6 4,8 28,7 24 53383 8 G 0,25 7,3 19,2 71,0 24
53378 3 G 0,25 4,9 7,2 33,7 24 53384 10 G 0,25 8,1 24,0 84,0 24
53379 4 G 0,25 5,5 9,6 41,8 24 53385 12 G 0,25 8,1 28,8 90,0 24
53380 5 G 0,25 5,8 12,0 47,0 24 53386 14 G 0,25 8,6 33,6 102,0 24
Continuation
221
Heat resistant Cables
222
Heat resistant Cables
Application
Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. They are heat-resistant for permanent temperature
up to +180C, for short time operation up to +220C. The good performance of the environmental resistant properties means that silicone cables
can be used at temperatures down to -60C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They
have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to
elastical characteristic of core insulations, these are used as flexible connection cable.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22989 2 x 0,5 5,6 9,6 42,0 20 23002 3 G 0,75 6,8 21,6 63,0 19
22990 3 G 0,5 5,9 14,5 44,0 20 23104 3 x 0,75 6,8 21,6 63,0 19
22940 3 x 0,5 5,9 14,5 44,0 20 23003 4 G 0,75 7,6 29,0 83,0 19
22991 4 G 0,5 6,4 19,3 58,0 20 23105 4 x 0,75 7,6 29,0 83,0 19
22941 4 x 0,5 6,4 19,3 58,0 20 23004 5 G 0,75 8,5 36,0 101,0 19
22992 5 G 0,5 7,3 24,0 62,0 20 22943 5 x 0,75 8,5 36,0 101,0 19
22942 5 x 0,5 7,3 24,0 62,0 20 23005 6 G 0,75 9,2 43,0 115,0 19
22993 6 G 0,5 8,3 28,9 79,0 20 23006 7 G 0,75 9,2 50,0 124,0 19
22994 7 G 0,5 8,1 33,7 85,0 20 23127 8 G 0,75 9,9 57,7 138,0 19
22995 8 G 0,5 8,9 38,4 99,0 20 23128 10 G 0,75 11,1 72,1 156,0 19
22996 10 G 0,5 10,0 48,1 124,0 20 23129 12 G 0,75 12,2 86,5 185,0 19
22997 12 G 0,5 10,6 57,6 141,0 20 23130 16 G 0,75 13,7 115,2 218,0 19
22998 16 G 0,5 12,1 76,7 186,0 20 23131 18 G 0,75 14,6 129,7 260,0 19
22999 18 G 0,5 12,7 86,5 211,0 20 23132 25 G 0,75 17,2 180,0 370,0 19
23000 25 G 0,5 15,2 120,0 271,0 20 23007 2x1 6,6 19,0 59,0 18
23001 2 x 0,75 6,4 14,4 53,0 19 23008 3G1 7,0 29,0 77,0 18
Continuation
223
Heat resistant Cables
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
22944 3x1 7,0 29,0 77,0 18 23141 10 G 2,5 15,5 240,1 450,0 14
23009 4G1 7,8 38,0 94,0 18 23033 12 G 2,5 17,1 288,0 502,0 14
22945 4x1 7,8 38,0 94,0 18 23142 16 G 2,5 19,6 384,0 659,0 14
23010 5G1 8,8 48,0 115,0 18 23143 18 G 2,5 20,6 432,2 761,0 14
22946 5x1 8,8 48,0 115,0 18 23144 25 G 2,5 24,4 600,0 1007,0 14
23011 6G1 9,5 58,0 134,0 18 23034 2x4 10,8 77,0 180,0 12
23012 7G1 9,5 67,0 144,0 18 23035 3G4 11,4 115,0 224,0 12
23133 8G1 10,3 76,7 175,0 18 23036 4G4 12,5 154,0 295,0 12
24000 9G1 11,5 86,0 196,0 18 23037 5G4 13,9 192,0 359,0 12
23134 10 G 1 11,5 96,1 216,0 18 23039 7G4 15,6 269,0 479,0 12
23135 12 G 1 12,5 115,2 231,0 18 23040 2x6 12,4 115,0 210,0 10
23136 16 G 1 14,2 153,5 302,0 18 23041 3G6 13,2 173,0 270,0 10
23137 18 G 1 15,1 172,9 340,0 18 23042 4G6 14,8 230,0 341,0 10
23138 25 G 1 18,0 240,0 431,0 18 23043 5G6 16,5 288,0 432,0 10
23013 2 x 1,5 7,6 29,0 81,0 16 23045 7G6 18,0 403,0 552,0 10
23014 3 G 1,5 8,0 43,0 98,0 16 23046 2 x 10 16,2 192,0 400,0 8
22947 3 x 1,5 8,0 43,0 98,0 16 23047 3 G 10 17,2 288,0 507,0 8
23015 4 G 1,5 8,7 58,0 122,0 16 23048 4 G 10 19,4 384,0 644,0 8
22948 4 x 1,5 8,7 58,0 122,0 16 23049 5 G 10 21,4 480,0 788,0 8
23016 5 G 1,5 9,6 72,0 147,0 16 23145 7 G 10 23,4 672,2 1151,0 8
22949 5 x 1,5 9,6 72,0 147,0 16 23050 2 x 16 18,0 308,0 591,0 6
23017 6 G 1,5 10,4 86,0 173,0 16 23051 3 G 16 19,3 462,0 749,0 6
23018 7 G 1,5 10,4 101,0 187,0 16 23052 4 G 16 21,4 616,0 950,0 6
23019 8 G 1,5 11,2 114,0 213,0 16 23053 5 G 16 24,0 770,0 1204,0 6
23020 10 G 1,5 13,0 116,0 263,0 16 23146 7 G 16 26,4 1075,3 1682,0 6
23021 12 G 1,5 13,9 173,0 314,0 16 23054 2 x 25 22,0 480,0 700,0 4
23022 14 G 1,5 14,7 202,0 379,0 16 23055 3 G 25 23,4 720,0 1100,0 4
23023 16 G 1,5 16,2 231,0 445,0 16 23056 4 G 25 26,3 960,0 1500,0 4
23024 18 G 1,5 17,0 260,0 506,0 16 23057 2 x 35 24,6 672,0 1100,0 2
23025 20 G 1,5 17,5 288,0 566,0 16 23058 3 G 35 26,3 1008,0 1500,0 2
23026 24 G 1,5 20,4 346,0 722,0 16 23059 4 G 35 29,1 1344,0 2100,0 2
23027 2 x 2,5 8,8 48,0 134,0 14
23028 3 G 2,5 9,7 72,0 152,0 14
23029 4 G 2,5 10,6 96,0 188,0 14
23030 5 G 2,5 11,6 120,0 228,0 14
23139 6 G 2,5 12,6 144,0 304,0 14
23032 7 G 2,5 12,6 168,0 320,0 14
23140 8 G 2,5 13,6 192,2 373,0 14
224
Heat resistant Cables
Technical data
adapted to DIN VDE 0285-525-2-83/
Cable structure
Tinned copper-conductor, to
Properties
Smoke density - low
E
DIN EN 50525-2-83 DIN VDE 0295 cl.5, fine-wire, Due to the special abrasive and notch
Temperature range BS 6360 cl.5, IEC 60228 cl.5 resistance outer sheath, these cables are
flexing -25C to +180C Core insulation of special silicone suitable for heavy loading of mechanical
fixed installation -60C to +180C compound type EI2 to stresses than the usual standard silicone
Nominal voltage U0/U 300/500 V DIN VDE 0207-363-1 / DIN EN 50363-1 cables
Test voltage 2000 V Core identification to DIN VDE 0293-308 Hardly changes of dielectric strength and
Insulation resistance - up to 5 cores coloured the insulation resistance also at high
min. 200 MOhm x km - from 6 cores, black with continuous temperatures
Minimum bending radius white numbering High ignition or flash point
flexing 7,5x cable GN-YE conductor, 3 cores and above leave in case of fire an insulating layer of
fixed installation 4x cable in the outer layer SiO2, thereby ensuring a longer functional
Radiation resistance Cores stranded in layers with integrity
up to 20x106 cJ/kg (up to 20 Mrad) optimal lay-length Resistant to
Tests Outer sheath of special silicone High molecular oils, fats from vegetables and
Insulation integrity compound type 2GM1 to animals, alcohols, plasticizers and clophenes,
testet acc. to DIN VDE 0472 part 814 DIN VDE 0207-363-2-1/DIN EN 50363-2-1 diluted acids, lyes and salt dissolution,
and IEC 60331 Sheath colour black (RAL 9005) oxidation substances, tropical influences and
Halogen-free with meter marking weather, lake water, oxygen, ozone
acc. to DIN VDE 0482 part 267,
DIN EN 50267-2-1, IEC 60754-1 Note
(equivalent DIN VDE 0472 part 815) G = with green-yellow conductor
Behaviour in fire x = without green-yellow conductor
no flame propagation acc. to AWG sizes are approximate equivalent
DIN VDE 0482-332-1-2, values. The actual cross-section is in mm.
DIN EN 60332-1-2,IEC 60332-1 (equivalent EWKF = Improved values to
DIN VDE 0472 part 804 test method B) E=tearing resistance,
Corrosiveness of combustion gases W=breaking strength propagation,
acc. to DIN VDE 0482 part 267, K=notch strength, F=flexibility
DIN EN 50267-2-2, IEC 60754-2 screened analogue type:
(equivalent DIN VDE 0472 part 813) THERMFLEX 180 EWKF-C, confer page 234
Application
These cables are ideal for use everywhere, where they are exposed to high mechanical stresses, as well as wire insulation are subjected to high
temperatures. For use in dry, damp and wet rooms, as well outdoor. Silicone cables are halogen free and are suitable for use in air conditioning and
heating, for lighting, for the wiring of ovens, saunas and solariums, foundries, steel, cement and ceramic works and in the heating and cooling
equipment.
FRNC = Flame Retardant Non Corrosive
All silicon cables are available also in FRNC versions. The sheath designed with special-compound conform flame test method C to DIN VDE 0472 part
804 and IEC 60332-3 as well as HD 405.3. This special compound is self-extinguishing. Because of that these cables can be installed as security cable
with functionality as for example in communal buildings, power stations, hotels, airports etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
74992 2 x 0,75 6,4 15,0 53,0 19 75008 2 G 2,5 9,8 48,0 135,0 14
74993 3 G 0,75 7,0 22,0 64,0 19 75009 3 G 2,5 10,4 72,0 152,0 14
74994 4 G 0,75 7,6 29,0 84,0 19 75010 4 G 2,5 11,5 96,0 189,0 14
74995 5 G 0,75 8,5 36,0 101,0 19 75011 5 G 2,5 12,9 120,0 229,0 14
74996 2x1 6,8 20,0 60,0 18 75012 2x4 11,6 77,0 180,0 12
74997 3G1 7,2 29,0 78,0 18 75013 3G4 12,3 115,0 230,0 12
74998 4G1 7,8 39,0 95,0 18 75014 4G4 13,6 154,0 300,0 12
74999 5G1 8,8 48,0 116,0 18 75015 5G4 15,2 192,0 380,0 12
75000 2 x 1,5 8,8 29,0 82,0 16 75016 2x6 13,2 115,0 321,0 10
75001 3 G 1,5 8,9 43,0 98,0 16 75017 3G6 14,0 173,0 330,0 10
75002 4 G 1,5 9,9 58,0 122,0 16 75018 4G6 15,5 230,0 430,0 10
75003 5 G 1,5 10,8 72,0 148,0 16 75019 5G6 17,2 288,0 550,0 10
75004 7 G 1,5 12,0 101,0 187,0 16
75005 12 G 1,5 16,1 173,0 315,0 16
75006 16 G 1,5 18,2 231,0 446,0 16
75007 20 G 1,5 19,4 288,0 566,0 16
225
Heat resistant Cables
Application
Multicore cables insulated and sheathed with heat resistant silicone rubber without strain relieving elements are used in high temperatures or with
contact to hot-surfaces. These cables are installed for fixed installation, mechanical protected, for internal wiring of lighting fixtures in industrial
application. It is recommended for the application of the apparatus which are moving during the operation with less mechanical stress.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05SS-F H05SST-F
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
22290 2 x 0,75 5,7 - 7,4 14,4 59,0 19 22343 2 x 0,75 6,7 - 8,4 14,4 63,0 19
22291 3 G 0,75 6,2 - 8,1 21,6 71,0 19 22344 3 G 0,75 7,2 - 9,1 21,6 75,0 19
22292 4 G 0,75 6,8 - 8,8 28,8 93,0 19 22345 4 G 0,75 7,8 - 9,8 28,8 99,0 19
22293 5 G 0,75 7,6 - 9,9 36,0 113,0 19 22346 5 G 0,75 8,6 - 10,9 36,0 120,0 19
22294 2x1 6,1 - 8,0 19,2 67,0 18 22347 2x1 7,1 - 9,0 19,2 71,0 18
22295 3G1 6,5 - 8,5 29,0 86,0 18 22348 3G1 7,5 - 9,5 29,0 91,0 18
22296 4G1 7,1 - 9,3 38,4 105,0 18 22349 4G1 8,1 - 10,3 38,4 111,0 18
22297 5G1 8,0 - 10,3 48,0 129,0 18 22350 5G1 9,0 - 11,3 48,0 137,0 18
22298 2 x 1,5 7,6 - 9,8 29,0 91,0 16 22351 2 x 1,5 8,6 - 10,8 29,0 97,0 16
22299 3 G 1,5 8,0 - 10,4 43,0 110,0 16 22352 3 G 1,5 9,0 - 11,4 43,0 117,0 16
22300 4 G 1,5 9,0 - 11,6 58,0 137,0 16 22353 4 G 1,5 10,0 - 12,6 58,0 145,0 16
22301 5 G 1,5 9,8 - 12,7 72,0 165,0 16 22354 5 G 1,5 10,8 - 13,7 72,0 175,0 16
22302 2 x 2,5 9,0 - 11,6 48,0 150,0 14 22355 2 x 2,5 10,0 - 12,6 48,0 159,0 14
22303 3 G 2,5 9,6 - 12,4 72,0 170,0 14 22356 3 G 2,5 10,6 - 13,4 72,0 180,0 14
22304 4 G 2,5 10,7 - 13,8 96,0 211,0 14 22357 4 G 2,5 11,7 - 14,8 96,0 224,0 14
22305 5 G 2,5 11,9 - 15,3 120,0 255,0 14 22358 5 G 2,5 12,9 - 16,3 120,0 270,0 14
22306 3G4 11,3 - 14,5 115,0 251,0 12 22359 3G4 12,3 - 15,5 115,0 266,0 12
22307 4G4 12,7 - 16,2 154,0 330,0 12 22360 4G4 13,7 - 17,2 154,0 350,0 12
22308 3G6 12,8 - 16,3 173,0 379,0 10 22361 3G6 13,8 - 17,3 173,0 402,0 10
22309 4G6 14,2 - 18,1 230,0 494,0 10 22362 4G6 15,2 - 19,1 230,0 524,0 10
226
Heat resistant Cables
Technical data
Fluorinated polymeric insulation FEP
Cable structure
Copper-conductor, bare, tinned, silver
Properties
Higher insulation resistance
E
(Fluorethylenepropylene) to DIN VDE 0295 cl.5, fine-wire, Low dielectric loss
Temperature range BS 6360 cl.5, IEC 60228 cl.5 Not flammable
-100C to +205C Core insulation of FEP-HELUFLON Resistant to micro-cultures
(for short time +230C) Core identification to DIN VDE 0293-308 Do not permit any fungus-formation
Conductor temperature range - up to 0,25 mm cores coloured Absolute ozone resistant
bare copper +130C - from 0,5 mm black cores with Absolute weather resistant
tinned copper +180C continuous white numbering Water absorption <0,01%
silver pl. copper +200C GN-YE conductor, 3 cores and above Minimal water vapour permeability (approx.
Nominal voltage 600 V Cores stranded in layers with 0,18 mgr/cm in 24 hours)
Test voltage 2500 V optimal lay-length The materials used in manufacture are
Insulation resistance Outer sheath of FEP-HELUFLON cadmium-free and contain no silicone
min. 2 GOhm x km Sheath colour black (RAL 9005) and free from substances harmful to
Minimum bending radius the wetting properties of lacquers
flexing 15x cable Tests
fixed installation 4x cable self-extinguishing and flame retardant
Radiation resistance acc. to DIN VDE 0482-332-1-2,
up to 1x106 cJ/kg (up to 1 Mrad) DIN EN 60332-1-2, IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method B)
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
This cables are predominantly used for installing in control cabinets subjected to high thermal effects as well as in brickworks, heaters, kitchen fitments
and measuring appliances as well as in the chemical industry. These cables are non-flammable and resistant to acids, alkalis, solvents, oil and petrol.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
copper wire, tinned copper wire, tinned
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
24547 2 x 0,25 2,7 5,0 17,0 24 24566 7G1 6,0 67,0 113,0 18
24548 3 G 0,25 2,9 7,5 22,0 24 24273 12 G 1 8,0 115,2 220,0 18
24549 4 G 0,25 3,2 10,0 27,0 24 24274 18 G 1 9,5 173,0 321,0 18
24550 5 G 0,25 3,5 12,5 34,0 24 24275 25 G 1 11,2 240,0 458,0 18
24551 7 G 0,25 3,9 17,5 46,0 24 24501 2 x 1,5 4,9 29,0 45,0 16
24552 2 x 0,5 3,3 9,8 21,0 20 24502 3 G 1,5 5,3 43,0 70,0 16
24553 3 G 0,5 3,5 14,7 32,0 20 24503 4 G 1,5 5,8 58,0 98,0 16
24554 4 G 0,5 3,9 19,6 44,0 20 24504 5 G 1,5 6,5 72,0 117,0 16
24555 5 G 0,5 4,3 24,5 55,0 20 24505 7 G 1,5 7,2 101,0 184,0 16
24556 7 G 0,5 4,8 34,3 70,0 20 24276 12 G 1,5 10,2 173,0 326,0 16
24557 2 x 0,75 3,6 14,4 31,0 19 24277 18 G 1,5 12,3 260,0 504,0 16
24558 3 G 0,75 3,9 21,6 46,0 19 24278 25 G 1,5 14,0 360,0 682,0 16
24559 4 G 0,75 4,3 29,0 58,0 19 24279 3 G 2,5 6,4 72,0 121,0 14
24560 5 G 0,75 4,7 36,0 69,0 19 24280 4 G 2,5 7,0 96,0 182,0 14
24561 7 G 0,75 4,8 50,0 92,0 19 24281 5 G 2,5 7,9 120,0 240,0 14
24562 2x1 4,1 19,0 41,0 18 24282 7 G 2,5 8,7 168,0 316,0 14
24563 3G1 4,4 29,0 55,0 18 24283 3G4 7,5 115,0 212,0 12
24564 4G1 4,9 38,0 71,0 18 24284 4G4 8,3 154,0 304,0 12
24565 5G1 5,5 48,0 88,0 18 24285 5G4 9,2 192,0 386,0 12
Continuation
227
Heat resistant Cables
228
Heat resistant Cables
Application
MULTITHERM 400 cables are used for applications where extremely high connecting and ambient temperatures can arise, e. g. in iron and steel works,
rolling mills, foundries, glass and ceramic factories, in furnace and power plant construction, during thermoplastic moulding processes etc. The special
construction of the cable is designed for a recommended maximum temperature in damp environmentsof 220C and for dry environments above this
temperature.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Max. permiss. Weight AWG-No. Part no. No.cores x Outer Cop. Max. permiss. Weight AWG-No.
cross-sec. approx. weight current carrying approx. cross-sec. approx. weight current carrying approx.
mm mm kg / km capacity kg / km mm mm kg / km capacity kg / km
at +340C (A) at +340C (A)
51741 2 x 0,5 6,2 10,0 3,3 47,0 20 51761 4 x 1,5 9,1 58,0 8,6 128,0 16
51742 3 x 0,5 6,4 15,0 3,1 50,0 20 51762 5 x 1,5 10,0 72,0 8,3 150,0 16
51743 4 x 0,5 7,5 19,0 3,0 70,0 20 51763 6 x 1,5 10,7 88,0 8,0 175,0 16
51744 5 x 0,5 8,0 25,0 2,9 81,0 20 51764 7 x 1,5 11,0 101,0 7,8 190,0 16
51745 6 x 0,5 8,6 30,0 2,8 97,0 20 51765 2 x 2,5 9,2 48,0 12,2 135,0 14
51746 7 x 0,5 8,7 34,0 2,7 105,0 20 51766 3 x 2,5 9,7 72,0 11,6 153,0 14
51747 2 x 0,75 6,7 14,4 5,1 55,0 19 51767 4 x 2,5 10,6 96,0 11,2 190,0 14
51748 3 x 0,75 7,0 21,6 5,1 66,0 19 50060 5 x 2,5 11,8 120,0 10,8 230,0 14
51749 4 x 0,75 8,0 29,0 4,9 86,0 19 50061 6 x 2,5 12,8 144,0 10,4 270,0 14
51750 5 x 0,75 8,8 36,0 4,7 103,0 19 50062 7 x 2,5 13,0 168,0 10,1 295,0 14
51751 6 x 0,75 9,5 43,0 4,5 119,0 19 50063 2x4 11,0 77,0 16,0 191,0 12
51752 7 x 0,75 9,7 50,0 4,4 130,0 19 50064 3x4 11,4 115,0 15,3 224,0 12
51753 2x1 6,9 19,0 7,0 63,0 18 50065 4x4 13,0 154,0 14,6 285,0 12
51754 3x1 7,8 29,0 6,7 82,0 18 50066 5x4 14,5 192,0 14,1 360,0 12
51755 4x1 8,3 38,0 6,4 98,0 18 50067 7x4 16,5 270,0 13,3 485,0 12
51756 5x1 9,1 48,0 6,2 119,0 18 50068 3x6 14,2 173,0 20,0 340,0 10
51757 6x1 9,8 58,0 6,0 138,0 18 50069 4x6 16,2 230,0 19,0 442,0 10
51758 7x1 10,0 67,0 5,8 150,0 18 50070 5x6 17,7 288,0 18,0 535,0 10
51759 2 x 1,5 8,0 29,0 9,4 87,0 16 50071 4 x 10 20,0 384,0 26,0 710,0 8
51760 3 x 1,5 8,3 43,0 9,0 103,0 16 50072 4 x 16 24,5 615,0 34,0 990,0 6
229
Heat resistant Cables
Application
These halogen-free, cross-linked and temperature resistant wiring and control cables with enhanced fire-behaviour properties are used for wiring up
the lighting fixtures, heaters, electric machines (temperature class B), switching systems and distribution switchboards. A very long service life is also
given on account of their excellent high-temperature stability. These cables exhibit good resistance to weathering as well as being very stable to
temperature, moisture, ozone and UV radiation. These cables are therfore mainly used for traffic control systems and diverse outdoor applications.
The development of smoke is low and no corrosive gases are liberated during combustion of these halogen-free cables in case of fire. The risk of toxic
fumes is considerably less in the event of fire because the coloric load values is lower. Precious time can thus be won for a disciplined evacuation, and
unnecessary loss of life can be prevented. The extent of the damage to costly control and monitoring systems and the concrete and steel structures
of buildings and plant due to fire is reduced by this. Injuries to persons and damage to materials can be prevented. A lower conductor cross-section
is possible in certain circumstances because of the high thermal load and thus savings in the space and weight required can be made. These wiring
and control cables provide a significant contribution in safety engineering and environmental protection.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
52194 2 x 0,25 5,0 16,0 36,0 24 52196 5 x 0,25 6,4 29,0 68,0 24
52195 3 x 0,25 5,5 21,0 44,0 24 52197 7 x 0,25 7,5 37,0 95,0 24
Continuation
230
Heat resistant Cables
231
Heat resistant Cables
Application
Silicone-rubber-insulated cables are used for all applications where the cable insulation is subjected to high temperature fluctuations. These cables
are heat-resistant for continuous use at temperatures up to +180C, as well as for short periods of time at +220C. Silicone-rubber-insulated cables
can also be used at low temperatures down to -60C because of the excellent weathering resistance of the material. These cables are halogen-free
and hence are particularly suitable for applications in iron and steel works, rolling mills, foundries, in aircraft construction and ship building, as well
as in cement, glass and ceramic plants. Silicone-rubber-insulated cables have demonstrated proven applications in projector and high-power lighting
fixtures as well as all types of heating equipment. An interference-free transmission of signals and pulse is assured by the high screening density. The
ideal interference-protected silicone multicore flexible cable for such applications as given above.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
23151 2 x 0,5 8,0 55,5 101,0 20 23160 2 x 0,75 9,0 61,4 124,0 19
23152 3 G 0,5 8,3 60,8 118,0 20 23161 3 G 0,75 9,4 69,1 136,0 19
23153 4 G 0,5 9,1 66,5 131,0 20 23162 4 G 0,75 10,4 86,7 159,0 19
23154 5 G 0,5 9,9 81,6 153,0 20 23163 5 G 0,75 11,3 95,2 180,0 19
23155 7 G 0,5 10,9 92,2 173,0 20 23164 7 G 0,75 12,0 113,3 212,0 19
23156 10 G 0,5 12,8 124,0 242,0 20 23165 10 G 0,75 13,9 165,2 306,0 19
23157 12 G 0,5 13,5 134,4 263,0 20 23166 12 G 0,75 15,2 180,3 333,0 19
23158 16 G 0,5 15,1 170,2 326,0 20 23167 16 G 0,75 16,9 212,2 418,0 19
23159 18 G 0,5 15,9 181,0 351,0 20 23168 18 G 0,75 18,0 282,1 453,0 19
23291 25 G 0,5 18,5 230,1 348,0 20 23292 25 G 0,75 20,8 297,4 468,0 19
Continuation
232
Heat resistant Cables
233
Heat resistant Cables
Application
These cables are ideal for use everywhere, where increased mechanical stresses for the installation and operation are required. Silicone-rubber-insulated
cables are used for all applications where the cable insulation is subjected to high temperature fluctuations. For use in dry, damp and wet rooms as
well outdoor. As flexible connecting cable for low mechanical stress i. e. sauna, solar installations, foundries and steel plants. This cable can be used
for fixed installation only in open and ventilated cable tubes and cable ducts. An interference-free transmission of signals and pulse is assured by the
high screening density.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
FRNC = Flame Retardant Non Corrosive
All silicon cables are available also in FRNC versions. The sheath designed with special-compound conform flame test method C to DIN VDE 0472 part
804 and IEC 60332-3 as well as HD 405.3. This special compound is self-extinguishing. Because of that these cables can be installed as security cable
with functionality as for example in communal buildings, power stations, hotels, airports etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
79804 2 x 0,75 9,0 61,4 124,0 19 79817 16 G 1,5 20,0 362,3 660,0 16
79805 3 G 0,75 9,4 69,1 136,0 19 79818 20 G 1,5 21,3 405,1 766,0 16
79806 4 G 0,75 10,4 86,7 160,0 19 79819 2 x 2,5 12,0 122,3 230,0 14
79807 5 G 0,75 11,2 95,2 180,0 19 79820 3 G 2,5 12,9 147,7 275,0 14
79808 2x1 9,4 66,7 132,0 18 79821 4 G 2,5 13,9 188,6 340,0 14
79809 3G1 9,8 86,2 154,0 18 79822 5 G 2,5 14,8 214,9 395,0 14
79810 4G1 10,7 96,8 176,0 18 79823 2x4 14,2 137,0 308,0 12
79811 5G1 11,6 108,3 207,0 18 79824 3G4 14,9 178,1 364,0 12
79812 2 x 1,5 10,8 87,7 170,0 16 79825 4G4 16,0 294,0 511,0 12
79813 3 G 1,5 11,2 103,5 190,0 16 79826 5G4 17,4 374,0 630,0 12
79814 4 G 1,5 12,0 131,7 231,0 16 79827 2x6 15,8 185,0 418,0 10
79815 5 G 1,5 12,8 148,5 282,0 16 79828 3G6 16,6 241,1 612,0 10
79816 7 G 1,5 13,6 193,4 342,0 16 79829 4G6 18,1 449,0 781,0 10
701219 12 G 1,5 17,2 298,4 531,0 16 79830 5G6 20,0 563,0 980,0 10
234
Heat resistant Cables
Application
Silicone cables screened with steel braiding were evolved for use wherever insulation is subjected to extreme temperature changes. They are heat-resistant
for permanent temperature up to +180C, for short time operation up to +220C. The good performance of the environmental resistant properties
means that silicone cables can be used at temperatures down to -60C. Silicone cables are halogen-free cables and are especially suited for installation
in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and
cement factories. The screened steel braiding ensures a disturbance-free transmission of signals and impulses.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
23062 2 x 0,75 7,9 14,4 90,0 19 23084 24 G 1,5 21,5 346,0 600,0 16
23063 3 G 0,75 8,3 21,6 101,0 19 23085 2 x 2,5 10,7 48,0 187,0 14
23064 4 G 0,75 9,3 29,0 129,0 19 23086 3 G 2,5 11,2 72,0 205,0 14
23065 5 G 0,75 10,0 36,0 157,0 19 23087 4 G 2,5 12,1 96,0 278,0 14
23067 7 G 0,75 10,7 50,0 177,0 19 23088 5 G 2,5 13,3 120,0 322,0 14
23068 2x1 8,0 19,0 97,0 18 23089 6 G 2,5 14,3 144,0 351,0 14
23069 3G1 8,9 29,0 122,0 18 23090 7 G 2,5 14,4 168,0 380,0 14
23070 4G1 9,4 38,0 141,0 18 23091 2x4 12,5 77,0 240,0 12
23071 5G1 10,4 48,0 166,0 18 23092 3G4 13,0 115,0 311,0 12
23073 7G1 11,1 67,0 197,0 18 23093 4G4 15,0 154,0 384,0 12
23074 2 x 1,5 9,0 29,0 127,0 16 23094 5G4 16,0 192,0 454,0 12
23075 3 G 1,5 9,5 43,0 145,0 16 23095 7G4 17,5 269,0 633,0 12
23076 4 G 1,5 10,3 58,0 173,0 16 23096 2x6 15,1 115,0 321,0 10
23077 5 G 1,5 11,0 72,0 202,0 16 23097 3G6 15,9 173,0 432,0 10
23078 6 G 1,5 12,0 86,0 240,0 16 23098 4G6 18,0 230,0 544,0 10
23079 7 G 1,5 12,0 101,0 244,0 16 23099 5G6 19,4 288,0 656,0 10
23080 8 G 1,5 13,0 115,0 261,0 16 23100 7G6 20,7 403,0 768,0 10
23081 12 G 1,5 15,5 173,0 327,0 16 23101 4 G 10 22,1 384,0 925,0 8
23082 14 G 1,5 16,2 202,0 382,0 16 23102 4 G 16 26,1 614,0 1235,0 6
23083 18 G 1,5 18,7 259,0 440,0 16 23103 4 G 25 30,4 960,0 1700,0 4
235
Heat resistant Cables
Application
Where extremely high connecting and ambient temperatures occur, e. g. in iron and steel works, rolling mills, foundries, glass and ceramic plants, in
power plant construction, in the chemical industry, nuclear technology, crude oil engineering, in technical applications in medicine, as well as for
wiring resistances in electrical heating equipment, furnaces and machinery in thermoplastic forming. Due to the special construction of the cable, a
maximum temperature of approx. 220C is recommended for use in damp environments. Applications at temperatures above this should be used in
dry environments only. The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The braided
screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Max. permiss. Weight AWG-No. Part no. No.cores x Outer Cop. Max. permiss. Weight AWG-No.
cross-sec. approx. weight current carrying approx. cross-sec. approx. weight current carrying approx.
mm mm kg / km capacity kg / km mm mm kg / km capacity kg / km
at +340C (A) at +340C (A)
52018 2 x 0,5 7,1 10,0 3,3 84,0 20 52038 4 x 1,5 10,0 58,0 8,6 183,0 16
52019 3 x 0,5 7,3 15,0 3,1 89,0 20 52039 5 x 1,5 10,9 72,0 8,3 212,0 16
52020 4 x 0,5 8,4 19,0 3,0 111,0 20 52040 6 x 1,5 11,6 88,0 8,0 241,0 16
52021 5 x 0,5 8,9 25,0 2,9 126,0 20 52041 7 x 1,5 11,9 101,0 7,8 259,0 16
52022 6 x 0,5 9,5 30,0 2,8 146,0 20 52042 2 x 2,5 10,1 48,0 12,2 191,0 14
52023 7 x 0,5 9,6 34,0 2,7 158,0 20 52043 3 x 2,5 10,6 72,0 11,6 213,0 14
52024 2 x 0,75 7,6 14,4 5,1 95,0 19 52044 4 x 2,5 11,5 96,0 11,2 256,0 14
52025 3 x 0,75 7,9 21,6 5,1 109,0 19 52045 5 x 2,5 12,7 120,0 10,8 307,0 14
52026 4 x 0,75 8,9 29,0 4,9 131,0 19 52046 6 x 2,5 14,9 144,0 10,4 359,0 14
52027 5 x 0,75 9,7 36,0 4,7 157,0 19 52047 7 x 2,5 15,1 168,0 10,1 388,0 14
52028 6 x 0,75 10,4 43,0 4,5 177,0 19 52048 2x4 11,9 77,0 16,0 260,0 12
52029 7 x 0,75 10,6 50,0 4,4 190,0 19 52049 3x4 12,3 115,0 15,3 303,0 12
52030 2x1 7,8 19,0 7,0 105,0 18 52050 4x4 15,1 154,0 14,6 378,0 12
52031 3x1 8,7 29,0 6,7 126,0 18 52051 5x4 15,6 192,0 14,1 458,0 12
52032 4x1 9,2 38,0 6,4 148,0 18 52052 7x4 16,6 270,0 13,3 593,0 12
52033 5x1 10,0 48,0 6,2 174,0 18 52053 3x6 16,3 173,0 20,0 442,0 10
52034 6x1 10,7 58,0 6,0 198,0 18 52054 4x6 18,3 230,0 19,0 567,0 10
52035 7x1 10,9 67,0 5,8 212,0 18 52055 5x6 19,8 288,0 18,0 671,0 10
52036 2 x 1,5 8,9 29,0 9,4 132,0 16 52056 4 x 10 22,1 384,0 26,0 866,0 8
52037 3 x 1,5 9,2 43,0 9,0 153,0 16 52057 4 x 16 26,6 615,0 34,0 1203,0 6
236
237
ALLWEATHER & RUBBER CABLES
3
in
E
VD eld 29
ng
x
xe
ex
VD
ed
U
R/ shi E 0
xi
- fi
- fl
./
0 /
le
ed
i
no
H A ed / VD
-f
-f
U
C)
C)
ge
us
us
CS REG
e n es /
(
e
lta
di
di
se
re
re
t
fre
ut tan
r
n
ra
ra
co
tu
tu
u
vo
E
ai
n-
or
sis
ra
ra
A
d
ch
al
ge
in
in
pe
pe
re
do
re
in
ge
nd
nd
ag
lo
lo
re
V-
m
L/
om
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
N
Allweather & rubber cables
TRAGO / Lift-2S -15 to +70 -40 to +70 300/500 20x 20x X X X 248
BAULIFTKABEL B101 / B102 / B103 -10 to +80 -10 to +80 300/500 10x 10x X X 249
HELUSPREADER YSLT-J -20 to +60 -20 to +60 300/500 15x 15x X X 250
239
Allweather, Rubber and Liftcables
Application
These robust rubber sheathed cables can be used where high demands are placed flexibility and mechanical stress. For application in dry, moist and
wet rooms and in open air, in steel works and rolling mills in heating and air-conditioning systems, in the bottling industry, in machinery and plant
construction, in the chemical industry as well as for the professional and the hobby enthusiast. The choice of yellow as the sheath colour ensures
additional safety. Can be used in potentially explosive areas acc. to DIN VDE 0165.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
37259 2x1 7,7 - 10,0 19,0 98,0 18 37273 2x4 11,8 - 15,1 77,0 282,0 12
37260 3G1 8,3 - 10,7 29,0 131,0 18 37274 3G4 12,7 - 16,2 115,0 322,0 12
37261 4G1 9,2 - 11,9 38,0 150,0 18 37275 4G4 14,0 - 17,9 154,0 397,0 12
37262 5G1 10,2 - 13,1 48,0 220,0 18 37276 5G4 15,6 - 19,9 192,0 486,0 12
37263 2 x 1,5 8,5 - 11,0 29,0 135,0 16 37277 4G6 15,7 - 20,0 230,0 541,0 10
37264 3 G 1,5 9,2 - 11,9 43,0 165,0 16 37278 5G6 17,5 - 22,2 288,0 652,0 10
37265 4 G 1,5 10,2 - 13,1 58,0 200,0 16 37279 4 G 10 20,9 - 26,5 384,0 952,0 8
37266 5 G 1,5 11,2 - 14,4 72,0 241,0 16 37280 5 G 10 22,9 - 29,1 480,0 1203,0 8
37267 7 G 1,5 16,5 - 16,5 101,0 375,0 16 37281 4 G 16 23,8 - 30,1 614,0 1260,0 6
37268 12 G 1,5 17,6 - 22,4 175,0 460,0 16 37282 5 G 16 26,4 - 33,3 768,0 1550,0 6
37269 2 x 2,5 10,2 - 13,1 48,0 194,0 14 37283 4 G 25 28,9 - 36,6 960,0 1860,0 4
37270 3 G 2,5 10,9 - 14,0 72,0 235,0 14 37284 5 G 25 32,0 - 40,4 1200,0 2250,0 4
37271 4 G 2,5 12,1 - 15,5 96,0 290,0 14 37285 4 G 35 32,5 - 41,1 1344,0 2374,0 2
37272 5 G 2,5 13,3 - 17,0 120,0 347,0 14 37286 5 G 35 40,6 - 40,6 1680,0 2752,0 2
240
Allweather, Rubber and Liftcables
Application
H05RR-F
These cables are suitable for connecting electrical appliances, for example vacuum cleaner, flat irons, soldering irons, kitchen appliances, toaster,
stoves etc. They were also used for medium mechanical stress in households and offices. These cables are suitable for fixed installation in partition
walls, furniture, decoration covering and in hollow spaces of prefabricated building parts. They are not suitable for use in open air, in industries (also
permitted to tailor workshops and of that kind) or in agriculture plants and for connecting commercial electrical tools.
H05RN-F
These cables are suitable for connecting electrical equipment with low mechanical stress in dry, damp and wet places as well in open air, for example
as connection cable for horticulture tools. These cables can be used in contact with fats and oils (for example deep fryer). They are also suitable for
fixed installation, for example in furniture, decoration covering, partition walls and in hollow spaces of prefabricated building parts. The installation
in hazardous areas is allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05RR-F H05RN-F
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
35001 2 x 0,75 5,7 - 7,4 14,4 60,0 19 36001 2 x 0,75 5,7 - 7,4 14,4 78,0 19
35005 3 G 0,75 6,2 - 8,1 21,6 74,0 19 36003 3 G 0,75 6,2 - 8,1 21,6 94,0 19
35009 4 G 0,75 6,8 - 8,8 29,0 78,0 19 36007 4 G 0,75 6,8 - 8,8 29,0 90,0 19
35019 5 G 0,75 7,6 - 9,9 36,0 99,0 19 36008 4 G 0,75 6,8 - 8,8 29,0 90,0 19
35002 2x1 6,1 - 8,0 19,0 72,0 18 36002 2x1 6,1 - 8,0 19,0 94,0 18
35006 3G1 6,5 - 8,5 29,0 85,0 18 36004 3G1 6,5 - 8,5 29,0 114,0 18
35010 4G1 7,1 - 9,3 38,0 98,0 18 36005 3 G 1,5 8,6 - 11,0 43,0 157,0 16
35020 5G1 8,0 - 10,3 48,0 134,0 18 36006 5 G 1,5 10,5 - 13,5 72,0 228,0 16
35003 2 x 1,5 7,6 - 9,8 29,0 98,0 16
35007 3 G 1,5 8,0 - 10,4 43,0 120,0 16
35011 4 G 1,5 9,0 - 11,6 58,0 150,0 16
35013 5 G 1,5 9,8 - 12,7 72,0 180,0 16
35004 2 x 2,5 9,0 - 11,6 48,0 145,0 14
35008 3 G 2,5 9,6 - 12,4 72,0 170,0 14
35012 4 G 2,5 10,7 - 13,8 96,0 220,0 14
35014 5 G 2,5 11,9 - 15,3 120,0 270,0 14
35015 3G4 11,3 - 14,5 115,0 260,0 12
35017 4G4 12,7 - 16,2 154,0 340,0 12
35016 3G6 12,8 - 16,3 173,0 361,0 10
35018 4G6 14,2 - 18,1 230,0 462,0 10
241
Allweather, Rubber and Liftcables
Application
Heavy duty rubber-sheathed flexible cables are suited for use for medium mechanical stress in dry, damp and wet areas as well as in open air and in
agriculture plants. They are used for equipment in industry works such as boilers, heating plates, hand lamps, electric tools such as drills, circular saws
and homework tools as well as for transportable motors or machines at site. These cables are also suitable for fixed installation on plaster, in temporary
buildings and residential barracks. They are suitable for direct laying on components and mechanical parts of machines, for example lifts and cranes.
They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage
up to 1000 V alternating voltage or a direct voltage up to 750 V against ground. The operating direct voltage is permitted up to 900 V against ground
when they are used in rail-coaches. Installation in hazardous areas according to DIN VDE 0165 is allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
37001 1 x 1,5 5,7 - 7,1 14,4 58,0 16 37021 2 x 2,5 10,2 - 13,1 48,0 193,0 14
37002 1 x 2,5 6,3 - 7,9 24,0 71,0 14 37022 2x4 11,8 - 15,1 77,0 280,0 12
37003 1x4 7,2 - 9,0 38,0 100,0 12 37023 2x6 13,1 - 16,8 115,0 330,0 10
37004 1x6 7,9 - 9,8 58,0 130,0 10 37024 2 x 10 17,7 - 22,6 192,0 586,0 8
37005 1 x 10 9,5 - 11,9 96,0 230,0 8 37025 2 x 16 20,2 - 25,7 307,0 810,0 6
37006 1 x 16 10,8 - 13,4 154,0 290,0 6 37026 2 x 25 24,3 - 30,7 480,0 1160,0 4
37007 1 x 25 12,7 - 15,8 240,0 420,0 4 37027 3G1 8,3 - 10,7 29,0 130,0 18
37008 1 x 35 14,3 - 17,9 336,0 530,0 2 37028 3 G 1,5 9,2 - 11,9 43,0 165,0 16
37009 1 x 50 16,5 - 20,6 480,0 750,0 1
37010 1 x 70 18,6 - 23,3 672,0 960,0 2/0
37011 1 x 95 20,8 - 26,0 912,0 1250,0 3/0
37012 1 x 120 22,8 - 28,6 1152,0 1560,0 4/0
37013 1 x 150 25,2 - 31,4 1440,0 1900,0 300 kcmil
37014 1 x 185 27,6 - 34,4 1776,0 2300,0 350 kcmil
37015 1 x 240 30,6 - 38,3 2304,0 2950,0 500 kcmil
37016 1 x 300 33,5 - 41,9 2880,0 3600,0 600 kcmil
37017 1 x 400 37,4 - 46,8 3840,0 4600,0 750 kcmil
37018 1 x 500 41,3 - 52,0 4800,0 6000,0 1000 kcmil
37019 2x1 7,7 - 10,0 19,0 98,0 18
37020 2 x 1,5 8,5 - 11,0 29,0 135,0 16
Continuation
242
Allweather, Rubber and Liftcables
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
37029 3 G 2,5 10,9 - 14,0 72,0 235,0 14 37056 4 G 120 53,0 - 66,0 4608,0 6830,0 4/0
37030 3G4 12,7 - 16,2 115,0 320,0 12 37057 4 G 150 58,0 - 73,0 5760,0 8320,0 300 kcmil
37031 3G6 14,1 - 18,0 173,0 420,0 10 37058 4 G 185 64,0 - 80,0 7104,0 9800,0 350 kcmil
37032 3 G 10 19,1 - 24,2 288,0 810,0 8 37059 4 G 240 72,0 - 91,0 9216,0 12100,0 500 kcmil
37033 3 G 16 21,8 - 27,6 461,0 1050,0 6 37060 4 G 300 80,0 - 101,0 11520,0 15200,0 600 kcmil
37034 3 G 25 26,1 - 33,0 720,0 1250,0 4 37061 5 G 1,5 11,2 - 14,4 72,0 240,0 16
37035 3 G 35 29,3 - 37,1 1008,0 1900,0 2 37062 5 G 2,5 13,3 - 17,0 120,0 345,0 14
37036 3 G 50 34,1 - 42,9 1440,0 2600,0 1 37063 5G4 15,6 - 19,9 192,0 485,0 12
37037 3 G 70 38,4 - 48,3 2016,0 3400,0 2/0 37064 5G6 17,5 - 22,2 288,0 650,0 10
37038 3 G 95 43,3 - 54,0 2736,0 4450,0 3/0 37065 5 G 10 22,9 - 29,1 480,0 1200,0 8
37039 3 G 120 47,4 - 60,0 3456,0 5180,0 4/0 37066 5 G 16 26,4 - 33,3 768,0 1550,0 6
37040 3 G 150 52,0 - 66,0 4320,0 6500,0 300 kcmil 37067 5 G 25 32,0 - 40,4 1200,0 2250,0 4
37041 3 G 185 57,0 - 72,0 5328,0 7860,0 350 kcmil 37068 5 G 35 35,7 - 45,1 1680,0 2750,0 2
37042 3 G 240 65,0 - 82,0 6912,0 10224,0 500 kcmil 37091 5 G 50 41,8 - 53,0 2400,0 3950,0 1
37043 3 G 300 72,0 - 90,0 8640,0 12620,0 600 kcmil 37154 5 G 70 47,5 - 60,0 3360,0 4740,0 2/0
37044 4G1 9,2 - 11,9 38,0 150,0 18 34090 5 G 95 54,0 - 67,0 4560,0 6600,0 3/0
37045 4 G 1,5 10,2 - 13,1 58,0 200,0 16 34349 5 G 120 58,0 - 73,0 5760,0 8180,0 4/0
37046 4 G 2,5 12,1 - 15,5 96,0 290,0 14 34127 5 G 150 64,0 - 80,0 7200,0 10600,0 300 kcmil
37047 4G4 14,0 - 17,9 154,0 395,0 12 37092 7 G 1,5 14,7 - 18,7 101,0 375,0 16
37048
37049
4G6
4 G 10
15,7 - 20,0
20,9 - 26,5
230,0
384,0
540,0
950,0
10
8
37079
37093
7 G 2,5
12 G 1,5
17,1 - 21,8
17,6 - 22,4
168,0
175,0
520,0
460,0
14
16 F
37050 4 G 16 23,8 - 30,1 614,0 1260,0 6 37096 12 G 2,5 20,6 - 26,2 288,0 760,0 14
37051 4 G 25 28,9 - 36,6 960,0 1860,0 4 37097 18 G 2,5 24,4 - 30,9 432,0 850,0 14
37052 4 G 35 32,5 - 41,1 1344,0 2380,0 2 37094 19 G 1,5 20,7 - 26,3 274,0 810,0 16
37053 4 G 50 37,7 - 47,5 1920,0 3190,0 1 37098 19 G 2,5 25,5 - 31,0 456,0 1075,0 14
37054 4 G 70 42,7 - 54,0 2688,0 4260,0 2/0 37095 24 G 1,5 24,3 - 30,7 346,0 1015,0 16
37055 4 G 95 48,4 - 61,0 3648,0 5600,0 3/0 37099 24 G 2,5 28,8 - 36,4 576,0 1390,0 14
243
Allweather, Rubber and Liftcables
Application
Heavy duty rubber-sheathed flexible cables are suited for use for medium mechanical stress in dry, damp and wet areas as well as in open air and in
agriculture plants. They are used for equipment in industry works such as boilers, heating plates, hand lamps, electric tools such as drills, circular saws
and homework tools as well as for transportable motors or machines at site. These cables are also suitable for fixed installation on plaster, in temporary
buildings and residential barracks. They are suitable for direct laying on components and mechanical parts of machines, for example lifts and cranes.
They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage
up to 1000 V alternating voltage or a direct voltage up to 750 V against ground. The operating direct voltage is permitted up to 900 V against ground
when they are used in rail-coaches. Installation in hazardous areas according to DIN VDE 0165 is allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
A07 RN-F (with green-yellow protective conductor) A07 RN-F (without green-yellow protective conductor)
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
37069 7 G 1,5 14,7 - 18,7 101,0 370,0 16 37080 3 x 1,5 9,2 - 11,9 43,0 165,0 16
37070 7 G 2,5 17,1 - 21,8 168,0 500,0 14 37081 3 x 2,5 10,9 - 14,0 72,0 235,0 14
37071 12 G 1,5 17,6 - 22,4 173,0 520,0 16 37082 3x4 12,7 - 16,2 115,0 320,0 12
37072 12 G 2,5 20,6 - 26,2 288,0 720,0 14 37083 3x6 14,1 - 18,0 173,0 495,0 10
37078 19 G 1,5 20,7 - 26,3 274,0 800,0 16 37084 3 x 10 19,1 - 24,2 288,0 880,0 8
37073 19 G 2,5 25,5 - 31,0 456,0 1100,0 14 37085 3 x 16 21,8 - 27,6 461,0 1095,0 6
37074 24 G 2,5 28,8 - 36,4 576,0 1350,0 14 37086 3 x 25 26,1 - 33,0 720,0 1450,0 4
37075 27 G 1,5 25,5 - 31,5 385,0 1100,0 16 37087 3 x 35 29,3 - 37,1 1008,0 1900,0 2
37076 27 G 2,5 30,0 - 37,0 640,0 1521,0 14 37088 3 x 50 34,1 - 42,9 1440,0 2600,0 1
37077 37 G 2,5 34,0 - 37,5 720,0 1940,0 14 37089 4 x 10 20,9 - 26,5 384,0 1065,0 8
37090 4 x 25 28,9 - 36,6 960,0 1995,0 4
244
Allweather, Rubber and Liftcables
Application
As robust and weather resistant cable for machines, equipment and appliances, which are constantly exposed to the outdoor weather conditions (e.
g. building machinery, conveyor and hoist systems, dry docks etc.). They are ideal for use as control cable in trailing cables. They are also suitable in
dry, damp and wet areas for wall- and push-button panels and as power cable. The core insulation is ozone resistant and the outer sheath made of
chloroprene is hardly flammable and abrasion resistant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Tensile Cop. Weight AWG-No. Part no. No.cores x Outer Tensile Cop. Weight AWG-No.
cross-sec. approx. strength weight approx. cross-sec. approx. strength weight approx.
mm mm of susp. kg / km kg / km mm mm of susp. kg / km kg / km
strand in N strand in N
25001 2x1 7,5 300 19,0 90,0 18 25038 48 G 1,5 34,9 - 691,0 1510,0 16
25002 3G1 8,5 150 29,0 111,0 18 25039 50 G 1,5 36,7 - 720,0 1642,0 16
25003 4G1 9,7 300 38,0 141,0 18 25040 61 G 1,5 41,8 - 878,0 1950,0 16
25004 5G1 11,5 300 48,0 170,0 18 25041 2 x 2,5 10,0 300 48,0 142,0 14
25005 6G1 13,4 - 58,0 187,0 18 25042 3 G 2,5 10,5 300 72,0 172,0 14
25006 7G1 13,8 2290 67,0 204,0 18 25043 4 G 2,5 11,6 570 96,0 210,0 14
25007 9G1 15,8 2890 86,0 274,0 18 25044 5 G 2,5 12,9 380 120,0 255,0 14
25008 12 G 1 17,5 6740 115,0 389,0 18 25045 6 G 2,5 14,5 - 144,0 318,0 14
25009 16 G 1 19,2 570 154,0 432,0 18 25046 7 G 2,5 16,2 3460 168,0 383,0 14
25010 18 G 1 21,5 960 173,0 471,0 18 25075 8 G 2,5 16,8 3850 192,0 450,0 14
25011 19 G 1 22,0 - 182,0 565,0 18 25047 9 G 2,5 21,5 680 216,0 541,0 14
25012 20 G 1 22,4 600 192,0 590,0 18 25048 11 G 2,5 23,3 - 264,0 638,0 14
25013 24 G 1 23,6 2890 230,0 650,0 18 25049 12 G 2,5 25,4 6060 288,0 690,0 14
25074 30 G 1 24,6 - 290,0 785,0 18 25050 16 G 2,5 24,4 - 383,0 813,0 14
25014 36 G 1 29,0 960 346,0 910,0 18 25051 18 G 2,5 26,3 2290 432,0 891,0 14
25015 37 G 1 30,5 - 355,0 936,0 18 25052 19 G 2,5 27,5 - 456,0 946,0 14
25016 48 G 1 31,4 1440 461,0 1244,0 18 25053 24 G 2,5 30,5 6060 576,0 1221,0 14
25017 50 G 1 32,6 - 480,0 1296,0 18 25054 36 G 2,5 33,3 - 864,0 1737,0 14
25018 54 G 1 32,9 2500 518,0 1399,0 18 25055 37 G 2,5 40,8 2500 888,0 1784,0 14
25019 61 G 1 37,2 2290 586,0 1495,0 18 25056 48 G 2,5 41,9 - 1152,0 2500,0 14
25020 2 x 1,5 8,5 300 29,0 95,0 16 25057 50 G 2,5 43,3 - 1200,0 2630,0 14
25021 3 G 1,5 9,3 150 43,0 113,0 16 25058 61 G 2,5 49,3 - 1464,0 8100,0 14
25022 4 G 1,5 10,5 570 58,0 150,0 16 25059 3G4 13,6 - 115,0 372,0 12
25023 5 G 1,5 12,5 870 72,0 180,0 16 25060 4G4 15,0 1000 154,0 407,0 12
25024 6 G 1,5 14,3 - 86,0 245,0 16 25061 5G4 17,1 600 192,0 432,0 12
25025 7 G 1,5 14,8 2600 101,0 309,0 16 25062 7G4 21,5 - 269,0 495,0 12
25026 8 G 1,5 15,8 3460 115,0 333,0 16 25063 3G6 13,9 - 173,0 380,0 10
25027 9 G 1,5 17,7 3850 130,0 360,0 16 25064 4G6 15,2 1000 230,0 445,0 10
25028 10 G 1,5 18,5 450 144,0 405,0 16 25065 5G6 19,2 900 288,0 569,0 10
25029 11 G 1,5 20,1 - 158,0 458,0 16 25066 7G6 21,1 - 403,0 702,0 10
25030 12 G 1,5 21,6 7710 173,0 516,0 16 25067 3 G 10 18,1 - 288,0 530,0 8
25031 13 G 1,5 22,1 - 187,0 571,0 16 25068 4 G 10 20,6 1200 384,0 724,0 8
25032 15 G 1,5 22,8 680 216,0 590,0 16 25069 5 G 10 22,6 1500 480,0 923,0 8
25033 18 G 1,5 23,6 960 259,0 620,0 16 25070 7 G 10 27,4 - 672,0 1288,0 8
25034 19 G 1,5 24,1 860 274,0 670,0 16 25071 3 G 16 21,3 - 461,0 865,0 6
25035 24 G 1,5 27,0 3850 346,0 817,0 16 25072 4 G 16 25,2 1920 614,0 1028,0 6
25036 37 G 1,5 31,0 - 533,0 1220,0 16 25073 5 G 16 26,5 2400 768,0 1260,0 6
25037 42 G 1,5 33,0 3460 605,0 1380,0 16
245
Allweather, Rubber and Liftcables
Application
Are suited as a connecting cable for very high mechanical stress in underground mining and tools for use in industries and outdoor use. They are also
used for mining industry, surface mining, stone-pits, on building sites, outdoors as well as indoors. Suitable for fixed installation on plaster in dry,
damp and wet areas. A long duration of life is guaranteed under extreme operating conditions. Not suitable for drumming and use in all types of
machinery, such as robots, handling units and energy transfer units, where constant mobility is essential. The insulation of a plastic-rubber compound
on EPR basis improves the resistance to ozone in order to avoid the formation of cracks due to ozone and insulation damages in switch-boards.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. max. mm weight approx. cross-sec. max. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
38001 1 x 16 13,5 154,0 336,0 6 38023 4 G 35 42,5 1344,0 2777,0 2
38002 1 x 25 16,5 240,0 473,0 4 38024 4 G 50 49,0 1920,0 3817,0 1
38003 1 x 35 18,0 336,0 635,0 2 38025 4 G 70 53,5 2688,0 5071,0 2/0
38004 1 x 50 20,0 480,0 866,0 1 38026 4 G 95 61,5 3648,0 6636,0 3/0
38005 1 x 70 22,0 672,0 1145,0 2/0 38027 4 G 120 68,0 4608,0 7000,0 4/0
38006 1 x 95 25,0 912,0 1475,0 3/0 38028 5 G 1,5 17,0 72,0 252,0 16
38007 1 x 120 27,5 1152,0 1832,0 4/0 38029 5 G 2,5 20,0 120,0 362,0 14
38008 1 x 150 30,0 1440,0 2000,0 300 kcmil 38030 5G4 23,0 192,0 509,0 12
38009 1 x 185 34,0 1776,0 2450,0 350 kcmil 38031 5G6 26,5 288,0 798,0 10
38010 1 x 240 37,0 2304,0 3190,0 500 kcmil 38035 5 G 10 30,0 480,0 1120,0 8
38011 2 x 2,5 16,0 48,0 205,0 14 38036 5 G 16 34,0 768,0 1680,0 6
38012 3 G 1,5 15,0 43,0 173,0 16 38037 5 G 25 42,0 1200,0 2430,0 4
38013 3 G 2,5 16,5 72,0 247,0 14 38038 7 G 1,5 19,5 101,0 470,0 16
38014 3G4 20,0 115,0 336,0 12 38032 7 G 2,5 21,5 168,0 546,0 14
38015 3G6 22,0 173,0 520,0 10 38039 10 G 1,5 22,0 144,0 560,0 16
38016 4 G 1,5 16,0 58,0 210,0 16 38033 12 G 2,5 28,0 288,0 851,0 14
38017 4 G 2,5 19,0 96,0 305,0 14 38040 18 G 2,5 33,0 432,0 1230,0 14
38018 4G4 21,5 154,0 415,0 12 38034 19 G 2,5 33,5 466,0 1260,0 14
38019 4G6 23,0 230,0 641,0 10
38020 4 G 10 27,5 384,0 1113,0 8
38021 4 G 16 37,0 614,0 1412,0 6
38022 4 G 25 39,0 960,0 2095,0 4
246
Allweather, Rubber and Liftcables
LIFT-TRAGO-30 / -60 lift hoist control cable, pendal length 30m resp. 60m
Application
These cables are used as control or feeder cables in lifts and hoists.
30 m pendal length - LIFT-TRAGO-30
60 m pendal length - LIFT-TRAGO-60
Suspension height for medium mechanical stresses in dry and moist rooms.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
LIFT-TRAGO-30
Part no. No.cores x Outer Cop. Weight Support core Pendal AWG-No.
cross-sec. approx. mm weight approx. kg / km length
mm kg / km max. m
25259 7G1 11,5 67,0 170,0 Textile 30 18
25260 12 G 1 15,7 115,0 325,0 Textile 30 18
25261 18 G 1 16,1 173,0 390,0 Textile 30 18
25262 24 G 1 19,2 230,0 530,0 Textile 30 18
LIFT-TRAGO-60
Part no. No.cores x Outer Cop. Weight Support core Pendal AWG-No.
cross-sec. approx. mm weight approx. kg / km length
mm kg / km max. m
25263 7G1 12,3 67,0 185,0 Textile 60 18
25264 12 G 1 16,2 115,0 335,0 Textile 60 18
25265 18 G 1 16,7 173,0 400,0 Textile 60 18
25266 24 G 1 19,8 230,0 540,0 Textile 60 18
25267 30 G 1 22,5 288,0 690,0 Textile 60 18
25268 36 G 1 28,2 346,0 930,0 Steel 60 18
247
Allweather, Rubber and Liftcables
Application
These cables are used as control or feeder cables in lifts and hoists. The special attention given to both production and material quality for these cables
has made them ideal even for use under extreme conditions. HELUKABEL-Lift-2S has also proven itself to be ideally suited for installation in conveyor
systems and manual control units. The external steel support wires can be dismounted without damaging the cable insulation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TRAGO with central support
Part no. No.cores x Outer Cop. Weight Support core Pendal AWG-No.
cross-sec. approx. mm weight approx. kg / km length
mm kg / km max. m
25080 7 G 0,75 15,4 50,0 290,0 Hemp 250 19
25081 12 G 0,75 19,2 86,0 360,0 Hemp 220 19
25082 18 G 0,75 21,0 130,0 455,0 Hemp 110 19
25083 24 G 0,75 23,0 173,0 535,0 Hemp 90 19
25084 7G1 14,9 67,0 222,0 Hemp 80 18
25085 12 G 1 20,0 115,0 415,0 Hemp 80 18
25086 18 G 1 21,4 173,0 450,0 Hemp 70 18
25087 20 G 1 21,6 192,0 490,0 Hemp 70 18
25088 24 G 1 23,2 230,0 605,0 Hemp 60 18
25089 36 G 1 26,1 346,0 950,0 Hemp 90 18
248
Allweather, Rubber and Liftcables
Application
These hybrid cables are used for power supply and control of vertical lifts in the construction industry. There are 3 cable versions.
Bauliftkabel B101: Here the cable is drawn vertically from a drum as a drag cable via the load platform. The load platform pulls the cable along as
it moves up. During the downwards motion the cable returns to the drum automatically. Our special versions are used at heights of up to about 150
m.
Bauliftkabel B102: For greater heights, a so-called carriage version is employed, in which the cable is fed at the centre of the tower, i. e. half the
way up.
Bauliftkabel B103: Here the cable is guided via a spring-loaded drum. These vertical construction lifts are used during new construction and
renovation work on high buildings. The rack lattice elements are fastened at intervals to the exterior facade.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Bauliftkabel B101 Bauliftkabel B102
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
73519 5 G 2,5 + 10 x 1,0 20,0 220,0 306,0 - 74293 4 G 16 + 1 x 2,5 + 2 x 2 x 1,0 28,5 830,0 1080,0 6
73913 5 G 2,5 + 11 x 1,0 20,0 225,6 320,0 14 74670 4 G 16 + 1 x 2,5 + 2 x 2 x 1,0 28,5 787,0 1080,0 6
70402 3 G 4 + 7 x 1,0 17,4 184,0 360,0 12 74297 4 G 25 + 1 x 2,5 + 2 x 2 x 1,0 33,4 1176,0 1500,0 4
70931 4 G 6 + 9 x 1,0 20,5 330,0 555,0 10 78122 4 G 35 + 4 x 2,5 + 2 x 2 x 1,0 38,0 1500,0 1850,0 2
70377 4 G 6 + 10 x 1,0 21,0 340,0 575,0 10 + 1 x 1,0
71901 4 G 6 + 15 x 1,0 22,0 388,0 625,0 10
71369 4 G 10 + 10 x 1,0 25,0 480,0 870,0 8 Bauliftkabel B103
78123 4 G 16 + 6 x 1,0 26,1 700,0 1250,0 6 Part no. No.cores x Outer Cop. Weight AWG-No.
78124 4 G 16 + 10 x 1,0 29,0 710,0 1300,0 6 cross-sec. approx. weight approx.
78125 4 G 16 + 15 x 1,0 31,5 760,0 1380,0 6 mm mm kg / km kg / km
73726 4 G 16 + 1 x 2,5 + 4 x 1,0 28,5 830,0 1460,0 6 77532 4 G 2,5 + 3 x 1,0 13,0 125,0 230,0 14
77538 4 G 2,5 + 3 x 1,0 15,3 125,0 280,0 14
249
Allweather, Rubber and Liftcables
Application
As Spreader cable with high mechanical stresses in vertical basket operation in dry, moist, wet environment and in open air. Please note that at the
installation the cable must be placed counterwise and free of twist into the basket.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight Tensile AWG-No. Part no. No.cores x Outer Cop. Weight Tensile AWG-No.
cross-sec. min. - max. weight approx. strain cross-sec. min. - max. weight approx. strain
mm mm kg / km kg / km max. N mm mm kg / km kg / km max. N
40160 36 G 2,5 38,1 - 41,0 864,0 2500,0 2000 14 40164 36 G 3,3 42,4 - 45,5 1140,0 3200,0 2000 12
40161 42 G 2,5 40,8 - 43,8 1008,0 3000,0 2000 14 40165 42 G 3,3 46,6 - 49,6 1330,0 3750,0 2000 12
40162 48 G 2,5 45,7 - 48,7 1152,0 3650,0 2000 14 40166 48 G 3,3 52,0 - 55,0 1521,0 4450,0 2000 12
40163 54 G 2,5 47,0 - 51,0 1296,0 4100,0 2000 14 40167 54 G 3,3 56,6 - 60,0 1711,0 5000,0 2000 12
250
TRAILING CABLES
3
in
E
VD eld 29
ng
x
xe
ex
VD
ed
U
R/ shi E 0
xi
- fi
- fl
./
0 /
le
ed
i
no
H A ed / VD
-f
-f
U
C)
C)
ge
us
us
CS REG
e n es /
(
e
lta
di
di
se
re
re
t
fre
ut tan
r
n
ra
ra
co
tu
tu
u
vo
E
ai
n-
or
sis
ra
ra
A
d
ch
al
ge
in
in
pe
pe
re
do
re
in
ge
nd
nd
ag
lo
lo
re
V-
m
L/
om
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
N
Trailing Cables
TROMMPUR -40 bis +80 -40 to +80 300/500 10x 10x X X X X 254
253
Trailing Cables
Application
TROMMPUR has taken the development of the neoprene type cables one step further. It is a robust, all-weather cable, halogen-free, tear and abrasion
resistant and suitable for use in drag-chains, in ship docks, on building sites, for conveyor systems, in mining, for tunnels and roadbuilding. For the
connecting the ski lift terminal positions to the control unit, surveillance of the joining rods in ski lift cables, as feeder cables for very high currents as
for example in pump engineering, mining, locomotive and rail-carriage construction, for oil rig platforms, emergency power generators etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
254
Trailing Cables
Application
This hybrid cable is designed for the aircraft industry, and contains cores for power supply, control cores, and cores for a positioning laser. The cable
is used to control and position a support robot, which absorbs loads at specific points when loading extremely heavy items, for example during loading
of aircraft assemblies in large transport aircraft of the Airbus industry. The cable is trailing, UV and weather-resistant, and is provided with an extremely
wear-resistant and petrol-resistant special sheath. Part no. 77548 is designed for similar applications, as a load-reducing lifter in aircraft assembly.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
70736 5 x 4 + 5 x 3 G 0,75 + 2 x 2 x 25,6 390,0 600,0 12 77548 5 x 2,5 + 18 G 1,0 + 4 x 2 x 0,34 27,0 461,0 750,0 14
0,34
255
Trailing Cables
Note
G = with green-yellow conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
Trailing cables are used for high mechanical stress, especially for applications with frequent winding and unwinding with simultaneous tensile and
torsional stress, for building machinery, conveyors, shifts and cranes. They are used as robust and all weather resistant cables of roughest operations
in mining and in flexible handling equipment and railway motors. The cables are suitable for outdoor installation in dry, damp and wet places as well
in open air. For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for reeling
cables. Please read the installation instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
26001 3 G 1,5 13,6 47,0 236,0 16 26019 4G4 18,5 158,0 510,0 12
26029 4 G 1,5 14,0 58,0 274,0 16 26030 5G4 21,5 220,0 635,0 12
26002 5 G 1,5 14,5 81,0 316,0 16 26020 4G6 21,0 241,0 650,0 10
26003 7 G 1,5 18,8 115,0 440,0 16 26031 5G6 23,5 317,0 800,0 10
26004 12 G 1,5 21,0 196,0 606,0 16 26021 4 G 10 26,0 404,0 1010,0 8
26005 16 G 1,5 24,5 259,0 696,0 16 26022 5 G 10 28,0 508,0 1200,0 8
26006 18 G 1,5 25,5 271,0 750,0 16 26023 4 G 16 29,0 642,0 1300,0 6
26007 24 G 1,5 27,5 390,0 1150,0 16 26032 5 G 16 31,5 768,0 1700,0 6
26008 30 G 1,5 29,5 432,0 1325,0 16 26024 4 G 25 35,0 1005,0 2000,0 4
26009 3 G 2,5 15,3 74,0 305,0 14 26025 4 G 35 37,5 1344,0 2610,0 2
26010 4 G 2,5 16,5 98,0 350,0 14 26026 4 G 50 44,5 2010,0 3500,0 1
26011 5 G 2,5 17,5 124,0 465,0 14 26027 4 G 70 49,0 2688,0 4600,0 2/0
26012 7 G 2,5 20,0 168,0 576,0 14 26028 4 G 95 56,0 3648,0 6100,0 3/0
26013 12 G 2,5 23,5 308,0 850,0 14
26014 18 G 2,5 28,0 451,0 1181,0 14
26015 24 G 2,5 32,5 615,0 1550,0 14
26016 30 G 2,5 34,0 770,0 1810,0 14
26017 40 G 2,5 42,5 1080,0 3110,0 14
26018 50 G 2,5 46,5 1200,0 3200,0 14
256
Trailing Cables
(N)SHTU-V Trailing-Cable
G
in short-circuit +250C Core identification to DIN VDE 0293-308 30 N/mm
Nominal voltage U0/U 0,6/1 kV (HD 308 S2) Tests
max. permissible operating voltage Cores stranded (without elongated Behaviour in fire
in three-phase and one-phase central core) with max. lay-length of to DIN VDE 0482-332-1-2
a.c. system U0/U 0,7/1,2 kV 8x over the stranded layers) DIN EN 60332-2-1, IEC 60332-1 (equivalent
in direct current system Depending on dimension/structure DIN VDE 0472 part 804 test method B)
U0/U 0,9/1,8 kV with Kevlar fillers Oil resistant to
Test voltage 4 kV Inner sheathof special rubber DIN VDE 0473-811-404,DIN EN 60811-404
Insulation resistance compound type 5GM5 to
min. 10 MOhm x km DIN VDE 0207 part 21 Note
Minimum bending radius Torsion protection between AWG sizes are approximate equivalent
7,5x cable inner and outer sheath values. The actual cross-section is in mm.
Outer sheath of special rubber
compound type 5GM5 to
DIN VDE 0207 part 21
Sheath colour yellow
Application
For vertical drum operation under extreme mechanical stress and on moving cable carrieres. Used as a rugged feeder to construction machines,
conveyor, transport and crane systems in dry, damp, wet environments and outdoors. For applications that go beyond standard solutions we recommend
you to our specially developed questionnaire for reeling cables. Please note installation instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Power supply Cable Control Cable (Kevlar fillers)
Part no. No.cores x Outer Cop. Weight Tensile AWG-No. Part no. No.cores x Outer Cop. Weight Tensile AWG-No.
cross-sec. min. - max. weight app. strain cross-sec. min. - max. weight app. strain
mm mm kg / km kg / km max. N mm mm kg / km kg / km max. N
31040 3 G 1,5 10,9 - 13,6 45,0 191,0 130 16 31078 49 G 1 31,0 - 34,5 470,0 1420,0 3450 18
31041 3 G 2,5 12,3 - 14,8 74,0 240,0 220 14 31079 7 G 1,5 14,6 - 16,9 115,0 320,0 2318 16
31042 3G4 14,9 - 17,6 115,0 362,0 360 12 31080 12 G 1,5 20,6 - 23,4 196,0 620,0 2540 16
31043 3G6 16,2 - 18,9 173,0 450,0 540 10 31081 18 G 1,5 20,3 - 22,9 271,0 650,0 2810 16
31044 3 G 10 19,6 - 22,6 288,0 682,0 900 8 31082 24 G 1,5 24,2 - 27,4 390,0 930,0 3080 16
31045 3 G 16 21,8 - 24,9 461,0 890,0 1440 6 31083 30 G 1,5 27,7 - 31,1 432,0 1190,0 3350 16
31046 3 G 25 27,5 - 30,8 720,0 1200,0 2250 4 31084 36 G 1,5 27,9 - 31,3 518,0 1240,0 3620 16
31047 3 x 50 + 3 G 25/3 36,9 - 40,6 1685,0 2810,0 4500 1 31085 44 G 1,5 31,2 - 34,8 634,0 1530,0 3980 16
31048 3 x 70 + 3 G 35/3 40,4 - 44,4 2355,0 3760,0 6300 2/0 31086 48 G 1,5 31,8 - 35,4 691,0 1610,0 4160 16
31049 3 x 95 + 3 G 50/3 46,6 - 50,8 3215,0 4700,0 8550 3/0 31087 56 G 1,5 35,9 - 39,7 807,0 2020,0 4520 16
31050 3 x 120 + 3 G 70/3 50,8 - 55,2 4130,0 5950,0 10800 4/0 31088 7 G 2,5 17,5 - 19,8 168,0 480,0 2520 14
31051 3 x 150 + 3 G 70/3 55,4 - 60,0 4990,0 7050,0 13500 300 kcmil 31089 12 G 2,5 23,8 - 26,7 308,0 915,0 2900 14
31090 18 G 2,5 23,4 - 26,2 451,0 945,0 3350 14
31052 3 x 185 + 3 G 95/3 60,8 - 65,7 6250,0 8800,0 16650 350 kcmil
31091 24 G 2,5 28,2 - 31,1 615,0 1330,0 3800 14
31053 3 x 240 + 3 G 120/3 68,8 - 74,0 8065,0 11700,0 21600 500 kcmil
31092 30 G 2,5 31,1 - 34,4 770,0 1615,0 4250 14
31054 4 G 1,5 11,8 - 14,5 58,0 220,0 180 16
31093 36 G 2,5 31,3 - 34,7 866,0 1710,0 4680 14
31055 4 G 2,5 14,4 - 17,1 99,0 330,0 300 14
31094 44 G 2,5 36,2 - 40,2 1057,0 2240,0 5250 14
31056 4G4 16,2 - 18,8 158,0 440,0 480 12 31095 48 G 2,5 37,2 - 41,0 1153,0 2410,0 5550 14
31057 4G6 17,4 - 20,2 241,0 530,0 720 10 31096 56 G 2,5 41,6 - 46,0 1344,0 2930,0 6150 14
31058 4 G 10 24,4 - 21,3 404,0 835,0 1200 8
31059 4 G 16 24,7 - 27,9 642,0 1175,0 1920 6
31060 4 G 25 31,4 - 34,9 1005,0 1850,0 3000 4
31061 4 G 35 37,5 - 33,9 1344,0 2250,0 4200 2
31062 4 G 50 40,3 - 44,2 2010,0 3210,0 6000 1
31063 4 G 70 44,5 - 48,6 2687,0 4210,0 8400 2/0
31064 4 G 95 51,1 - 55,5 3646,0 5550,0 11400 3/0
31065 4 G 120 57,4 - 62,0 4605,0 7010,0 14400 4/0
31066 4 G 150 62,6 - 67,6 5765,0 8450,0 18000 300 kcmil
31067 4 G 185 68,1 - 73,2 7110,0 10000,0 22200 350 kcmil
31068 5 G 1,5 12,8 - 15,5 73,0 258,0 220 16
31069 5 G 2,5 15,5 - 18,2 124,0 389,0 370 14
31070 5G4 17,4 - 20,2 220,0 511,0 600 12
31071 5G6 19,6 - 22,7 317,0 688,0 900 10
31072 5 G 10 23,2 - 26,3 508,0 1002,0 1500 8
31073 5 G 16 26,7 - 30,2 768,0 1395,0 2400 6
31074 5 G 25 34,1 - 37,7 1200,0 2205,0 3750 4
31075 5 G 35 38,3 - 42,2 1680,0 2960,0 5250 2
31076 5 G 50 43,8 - 47,8 2400,0 3950,0 7500 1
31077 5 G 70 50,2 - 54,6 3360,0 5455,0 10500 2/0
257
Trailing Cables
Application
Reeling medium voltage supply train for use in high mechanical stresses, such as in in container cranes or large mobile equipment as well as excavators
in the mining industry for days, in dry, damp, wet areas and outdoors.
3,6/6kV 8,7/15kV
Part no. No.cores x Outer Permanent Tensile Cop. Weight Part no. No.cores x Outer Permanent Tensile Cop. Weight
cross-sec. min. - max. load strain weight app. cross-sec. min. - max. load strain weight app.
mm mm N max. N kg / km kg / km mm mm N max. N kg / km kg / km
38533 3 x 25 + 3 x 10 37,0 - 40,0 1500 2200 1008,0 2280,0 - 38545 3 x 25 + 3 x 10 43,0 - 46,0 1500 2200 1008,0 2750,0 -
38534 3 x 35 + 3 x 10 40,0 - 43,0 2000 3100 1292,0 2750,0 - 38546 3 x 35 + 3 x 10 46,0 - 48,0 2000 3100 1292,0 3210,0 -
38535 3 x 50 + 3 x 10 44,0 - 47,0 3000 4300 1728,0 3400,0 - 38547 3 x 50 + 3 x 10 49,0 - 52,0 3000 4300 1728,0 3950,0 -
38536 3 x 70 + 3 x 16 47,0 - 50,0 4100 5100 2477,0 4100,0 - 39040 3 x 70 + 3 x 16 53,0 - 57,0 4100 5100 2477,0 5000,0 -
38537 3 x 95 + 3 x 16 52,0 - 56,0 5600 7000 3197,0 5450,0 - 39041 3 x 95 + 3 x 16 58,0 - 62,0 5600 7000 3197,0 6150,0 -
38538 3 x 120 + 3 x 25 56,0 - 60,0 7100 8500 4176,0 6650,0 - 39042 3 x 120 + 3 x 25 63,0 - 67,0 7100 8500 4176,0 7700,0 -
6/10kV 12/20kV
Part no. No.cores x Outer Permanent Tensile Cop. Weight Part no. No.cores x Outer Permanent Tensile Cop. Weight
cross-sec. min. - max. load strain weight app. cross-sec. min. - max. load strain weight app.
mm mm N max. N kg / km kg / km mm mm N max. N kg / km kg / km
38539 3 x 25 + 3 x 10 39,0 - 42,0 1500 2200 1008,0 2400,0 - 39043 3 x 25 + 3 x 10 46,0 - 49,0 1500 2200 1008,0 3040,0 -
38540 3 x 35 + 3 x 10 42,0 - 45,0 2000 3100 1292,0 2900,0 - 39044 3 x 35 + 3 x 10 49,0 - 52,0 2000 3100 1292,0 3510,0 -
38541 3 x 50 + 3 x 10 45,0 - 48,0 3000 4300 1728,0 3450,0 - 39045 3 x 50 + 3 x 10 53,0 - 57,0 3000 4300 1728,0 4410,0 -
38542 3 x 70 + 3 x 16 50,0 - 54,0 4100 5100 2477,0 4600,0 - 39046 3 x 70 + 3 x 16 57,0 - 61,0 4100 5100 2477,0 5420,0 -
38543 3 x 95 + 3 x 16 54,0 - 58,0 5600 7000 3197,0 5770,0 - 39047 3 x 95 + 3 x 16 62,0 - 66,0 5600 7000 3197,0 6750,0 -
38544 3 x 120 + 3 x 25 58,0 - 62,0 7100 8500 4176,0 6900,0 - 39048 3 x 120 + 3 x 25 67,0 - 70,0 7100 8500 4176,0 8050,0 -
258
ROBOT CABLES
3
in
E
VD eld 29
ng
x
xe
ex
VD
ed
U
R/ shi E 0
xi
- fi
- fl
./
0 /
le
ed
i
no
H A ed / VD
-f
-f
U
C)
C)
ge
us
us
CS REG
e n es /
(
e
lta
di
di
se
re
re
t
fre
ut tan
r
n
ra
ra
co
tu
tu
u
vo
E
ai
n-
or
sis
ra
ra
A
d
ch
al
ge
in
in
pe
pe
re
do
re
in
ge
nd
nd
ag
lo
lo
re
V-
m
L/
om
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
N
Robot cables
ROBOFLEX recycle -30 to +105 -40 to +105 300 7.5x 7.5x X X X X 262
ROBOFLEX 2001 / 2001-C -30 to +80 -40 to +80 300/500 7.5x 7.5x X X /X 264
ROBOFLEX 150,...151,...152,...153
-40 to +80 -40 to +80 300/500 15x 15x X X X /X X 265
261
Robot Cables
ROBOFLEX recycle
Application
The cables with this new sheath material cover all requirements for very large mechanical stresses for abrasion, tear resistance, torsion, flexing, flexibility
and oil resistance. Using for automation technology, plant and machine construction, fixture construction for handling devices, welding devices and
welding tongs, assembly and handling devices, machining production, welding robots and tool machines, blast furnaces and rolling mills. The completely
new feature of this cable is the weld splatter resistance without the otherwise usual and required cross-linking process. Our newly developed
non-cross-linked thermoplastic elastomer is fully recyclable. In contrast to this, the usual, cross-linked, thermoplastic elastomers cannot be recycled
and put a not insignificant stress on our environment. This must be particularly interesting for customers who have an environment management
system according to DIN EN ISO 14001 and thus place a great deal of importance on the use of recyclable materials. A significantly longer service life
than that of existing cables on the market, because it can be used in highly flexible applications, for example on robots (torsion) and in drag chains
(dynamic load).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
ROBOFLEX recycle
Part no. Cable structure AWG-No.
Sheath colour No.cores x Core colours High Outer Cop. Weight
cross-sec. flex ** approx. mm weight approx.
mm kg / km kg / km
701889 BK RAL 9005 3 x 0,25 BN, BU, BK X 4,4 7,2 22,0 -
701891 YE RAL 1021 3 x 0,25 BN, BU, BK X 4,4 7,2 22,0 -
701890 GY RAL 7001 3 x 0,25 BN, BU, BK X 4,4 7,2 22,0 -
701894 YE RAL 1021 4 x 0,25 BN, BU, BK, WH X 4,7 9,6 26,0 -
701892 BK RAL 9005 4 x 0,25 BN, BU, BK, WH X 4,7 9,6 26,0 -
701893 GY RAL 7001 4 x 0,25 BN, BU, BK, WH X 4,7 9,6 26,0 -
701897 YE RAL 1021 5 x 0,25 BN, BU, BK, WH, GY X 4,8 12,0 30,0 -
701895 BK RAL 9005 5 x 0,25 BN, BU, BK, WH, GY X 4,8 12,0 30,0 -
701896 GY RAL 7001 5 x 0,25 BN, BU, BK, WH, GY X 4,8 12,0 30,0 -
702805 YE RAL 1021 8 x 0,25 DIN 47100 X 6,0 19,2 55,0 -
702803 BK RAL 9005 8 x 0,25 DIN 47100 X 6,0 19,2 55,0 -
702804 GY RAL 7001 8 x 0,25 DIN 47100 X 6,0 19,2 55,0 -
701900 YE RAL 1021 3 x 0,34 BN, BU, BK X 4,9 9,8 30,0 -
701898 BK RAL 9005 3 x 0,34 BN, BU, BK X 4,9 9,8 30,0 -
701899 GY RAL 7001 3 x 0,34 BN, BU, BK X 4,9 9,8 30,0 -
Continuation
262
Robot Cables
ROBOFLEX recycle
ROBOFLEX recycle
Part no. Cable structure AWG-No.
Sheath colour No.cores x Core colours High Outer Cop. Weight
cross-sec. flex ** approx. mm weight approx.
mm kg / km kg / km
701903 YE RAL 1021 4 x 0,34 BN, BU, BK, WH X 5,2 13,1 43,0 -
701901 BK RAL 9005 4 x 0,34 BN, BU, BK, WH X 5,2 13,1 43,0 -
701902 GY RAL 7001 4 x 0,34 BN, BU, BK, WH X 5,2 13,1 43,0 -
701906 YE RAL 1021 5 x 0,34 BN, BU, BK, WH, GY X 5,9 16,4 54,0 -
701904 BK RAL 9005 5 x 0,34 BN, BU, BK, WH, GY X 5,9 16,4 54,0 -
701905 GY RAL 7001 5 x 0,34 BN, BU, BK, WH, GY X 5,9 16,4 54,0 -
702808 YE RAL 1021 8 x 0,34 DIN 47100 X 6,8 26,1 78,0 -
702806 BK RAL 9005 8 x 0,34 DIN 47100 X 6,8 26,1 78,0 -
702807 GY RAL 7001 8 x 0,34 DIN 47100 X 6,8 26,1 78,0 -
701910 YE RAL 1021 5 G 0,5 BK with number, GN-YE X 6,0 24,0 65,0 -
701908 BK RAL 9005 5 G 0,5 BK with number, GN-YE X 6,0 24,0 65,0 -
701909 GY RAL 7001 5 G 0,5 BK with number, GN-YE X 6,0 24,0 65,0 -
701913 YE RAL 1021 5 G 0,75 BK with number, GN-YE X 7,0 36,0 80,0 -
701911 BK RAL 9005 5 G 0,75 BK with number, GN-YE X 7,0 36,0 80,0 -
701912 GY RAL 7001 5 G 0,75 BK with number, GN-YE X 7,0 36,0 80,0 -
H
703847 GY RAL 7001 4 x 0,25 BN, BU, BK, WH X 5,2 19,4 46,3 -
703851 YE RAL 1021 5 x 0,25 BN, BU, BK, WH, GY X 5,3 22,5 50,0 -
703849 BK RAL 9005 5 x 0,25 BN, BU, BK, WH, GY X 5,3 22,5 50,0 -
703850 GY RAL 7001 5 x 0,25 BN, BU, BK, WH, GY X 5,3 22,5 50,0 -
703869 YE RAL 1021 8 x 0,25 DIN 47100 X 6,8 34,1 53,5 -
703867 BK RAL 9005 8 x 0,25 DIN 47100 X 6,8 34,1 53,5 -
703868 GY RAL 7001 8 x 0,25 DIN 47100 X 6,8 34,1 53,5 -
703854 YE RAL 1021 3 x 0,34 BN, BU, BK X 5,2 19,6 48,2 -
703852 BK RAL 9005 3 x 0,34 BN, BU, BK X 5,2 19,6 48,2 -
703853 GY RAL 7001 3 x 0,34 BN, BU, BK X 5,2 19,6 48,2 -
703857 YE RAL 1021 4 x 0,34 BN, BU, BK, WH X 5,4 23,7 53,0 -
703855 BK RAL 9005 4 x 0,34 BN, BU, BK, WH X 5,4 23,7 53,0 -
703856 GY RAL 7001 4 x 0,34 BN, BU, BK, WH X 5,4 23,7 53,0 -
703860 YE RAL 1021 5 x 0,34 BN, BU, BK, WH, GY X 5,8 28,7 61,9 -
703858 BK RAL 9005 5 x 0,34 BN, BU, BK, WH, GY X 5,8 28,7 61,9 -
703859 GY RAL 7001 5 x 0,34 BN, BU, BK, WH, GY X 5,8 28,7 61,9 -
703872 YE RAL 1021 8 x 0,34 DIN 47100 X 7,3 58,0 85,0 -
703870 BK RAL 9005 8 x 0,34 DIN 47100 X 7,3 58,0 85,0 -
703871 GY RAL 7001 8 x 0,34 DIN 47100 X 7,3 58,0 85,0 -
703863 YE RAL 1021 5 G 0,5 BK with number, GN-YE X 7,0 52,0 76,0 -
703861 BK RAL 9005 5 G 0,5 BK with number, GN-YE X 7,0 52,0 76,0 -
703866 YE RAL 1021 5 G 0,75 BK with number, GN-YE X 7,6 70,0 93,0 -
703864 BK RAL 9005 5 G 0,75 BK with number, GN-YE X 7,6 70,0 93,0 -
703865 GY RAL 7001 5 G 0,75 BK with number, GN-YE X 7,6 70,0 93,0 -
263
Robot Cables
Application
These special robotic control and signal cables specially designed for torsion and bending stresses in robots and connecting handling tools.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
ROBOFLEX 2001 ROBOFLEX 2001-C
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
25459 7 x 0,25 5,8 16,8 48,0 24 25539 10 x 0,14 7,8 34,2 62,0 26
25439 12 x 0,25 7,6 28,8 71,0 24 25488 12 x 0,14 7,8 42,1 95,0 26
25460 25 x 0,25 10,6 60,0 143,0 24 25489 18 x 0,14 9,7 54,5 120,0 26
25461 2 x 0,34 4,0 6,6 28,0 22 25490 25 x 0,14 10,9 69,0 158,0 26
25462 3 x 0,34 4,0 9,8 34,0 22 25491 12 x 0,25 8,3 59,5 126,0 24
25440 7 x 0,34 5,7 22,8 51,0 22 25492 18 x 0,25 10,1 80,0 164,0 24
25449 12 x 0,34 8,3 39,2 69,0 22 25493 25 x 0,25 11,1 103,0 215,0 24
25463 12 G 0,5 10,4 57,8 90,0 20 25494 12 x 0,34 8,8 78,0 160,0 22
25519 16 G 0,5 11,6 76,8 277,0 20 25495 18 x 0,34 10,8 101,0 210,0 22
25464 18 G 0,5 12,7 86,4 121,0 20 25496 25 x 0,34 12,0 158,0 305,0 22
25465 25 G 0,5 14,2 120,0 256,0 20 25497 12 G 0,5 11,2 117,0 175,0 20
25466 4 G 0,75 6,0 28,8 63,0 19 25498 18 G 0,5 13,6 160,0 231,0 20
25450 7 G 0,75 7,9 50,4 96,0 19 25499 25 G 0,5 14,8 255,0 347,0 20
25467 12 G 0,75 11,5 84,4 171,0 19 25500 12 G 0,75 11,8 155,0 220,0 19
25468 14 G 0,75 12,8 100,8 200,0 19 25501 18 G 0,75 15,0 210,0 305,0 19
25469 2x1 5,5 19,2 48,0 18 25502 25 G 0,75 16,6 275,0 415,0 19
25470 3G1 6,0 29,0 60,0 18 705462 3G1 6,3 76,0 90,0 18
25471 4G1 6,3 38,4 78,0 18 25503 12 G 1 13,0 190,0 265,0 18
25472 7G1 8,5 67,2 131,0 18 25504 18 G 1 16,1 245,0 390,0 18
25473 12 G 1 12,5 115,2 216,0 18 25505 25 G 1 18,1 345,0 540,0 18
25474 18 G 1 15,4 172,8 306,0 18 25506 12 G 1,5 16,2 260,0 345,0 16
25475 25 G 1 17,4 240,0 432,0 18 25507 18 G 1,5 20,3 370,0 485,0 16
25476 34 G 1 21,3 326,4 569,0 18 25508 25 G 1,5 22,5 498,0 710,0 16
25477 41 G 1 23,2 393,6 694,0 18
25520 3 G 1,5 6,9 43,2 94,0 16
25529 4 G 1,5 7,9 57,6 107,0 16
25559 5 G 1,5 8,6 72,0 121,0 18
25509 8 G 1,5 11,1 115,2 292,0 16
25478 12 G 1,5 15,5 172,8 356,0 16
25479 18 G 1,5 19,3 259,2 445,0 16
25480 25 G 1,5 21,8 360,0 636,0 16
25481 3 G 2,5 8,4 72,0 136,0 14
25482 4 G 2,5 9,1 96,0 170,0 14
25483 3G4 10,3 116,0 227,0 12
25530 4G4 11,2 153,6 261,0 12
25510 4G6 14,1 230,4 341,0 10
25484 3 G 10 15,6 288,0 518,0 8
25485 3 G 16 18,2 460,8 722,0 6
25486 3 G 25 22,9 720,0 1180,0 4
25487 3 G 35 26,5 1008,0 1600,0 2
264
Robot Cables
Application
These cables are specially designed for combined torsional and bending stresses. They are employed both for power supply and for the transmission
of control and monitoring signals. ROBOFLEX cables are used in assembly and welding robots, in handling and automation centres, in transport and
conveyor equipment, and on turntables and swivel tables. In other words, anywhere where there is no defined cable routing with only alternating
bending cycles on a single plane such as in drag chains.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
265
Robot Cables
ROBOFLEX 151, Sheath colour grey ROBOFLEX 153, Sheath colour black
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
70116 12 G 0,5 8,3 57,6 131,0 20 76172 4 G 1,5 8,5 57,6 106,0 16
76168 4 G 1,5 8,5 57,6 106,0 16 76174 4G4 12,7 153,6 283,0 12
76169 4 G 2,5 10,8 96,0 196,0 14 76175 4G6 15,0 230,4 432,0 10
76170 4G4 12,7 153,6 283,0 12
76171 4G6 15,0 230,4 432,0 10
266
Robot Cables
Application
These cables are designed for use with autonomous sewer robots. These robots are used to inspect municipal sewer networks and if necessary to
locate leaks or blockages. Some of these robots are even able to seal such leaks after detecting them. Besides cores for power supply, they also contain
data cables, hoses for various drives, and coaxial cables for the video camera mounted on the robot.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
267
WATER-RESISTANT CABLES
3
in
E
VD eld 29
ng
x
xe
ex
VD
ed
U
R/ shi E 0
xi
- fi
- fl
./
0 /
le
ed
i
no
H A ed / VD
-f
-f
U
C)
C)
ge
us
us
CS REG
e n es /
(
e
lta
di
di
se
re
re
t
fre
ut tan
r
n
ra
ra
co
tu
tu
u
vo
E
ai
n-
or
sis
ra
ra
A
d
ch
al
ge
in
in
pe
pe
re
do
re
in
ge
nd
nd
ag
lo
lo
re
V-
m
L/
om
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
N
Water-resistant cables
269
Water resistant Cables
Application
Tauchflex-R is a special cable for use as a connecting and control cable for submersible motor pumps, underwater floodlights, floating switch and has
proven its worth for constant use in drinking water, process water and service water up to an immersion depth of 300 m.
Tauchflex-R can also be installed for use in dry, damp and humid areas as well as in the open air. Not suitable for the installation in hazardous areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
37100 1 x 1,5 6,0 14,0 54,0 16 37127 3 G 10 19,0 288,0 750,0 8
37101 1 x 2,5 6,7 24,0 76,0 14 37128 3 G 16 23,5 461,0 1110,0 6
37102 1x4 7,2 38,0 105,0 12 37129 3 G 25 28,5 720,0 1450,0 4
37103 1x6 7,9 58,0 135,0 10 37130 3 G 35 32,0 1008,0 2150,0 2
37104 1 x 10 9,5 96,0 200,0 8 37131 3 G 50 37,0 1440,0 2800,0 1
37105 1 x 16 11,5 154,0 290,0 6 37132 3 G 70 42,0 2016,0 3750,0 2/0
37106 1 x 25 13,5 240,0 400,0 4 37133 3 G 95 43,3 2736,0 4590,0 3/0
37107 1 x 35 15,0 336,0 560,0 2 37134 3 G 120 49,0 3456,0 5400,0 4/0
37108 1 x 50 17,5 480,0 730,0 1 37135 4 G 1,5 10,7 58,0 190,0 16
37109 1 x 70 20,0 672,0 1000,0 2/0 37136 4 G 2,5 12,3 96,0 270,0 14
37110 1 x 95 22,5 912,0 1250,0 3/0 37137 4G4 14,0 154,0 380,0 12
37111 1 x 120 24,0 1152,0 1650,0 4/0 37138 4G6 15,5 230,0 520,0 10
37112 1 x 150 25,2 1440,0 2000,0 300 kcmil 37139 4 G 10 21,0 384,0 955,0 8
37113 1 x 185 27,6 1776,0 2460,0 350 kcmil 37140 4 G 16 25,5 614,0 1400,0 6
37114 1 x 240 30,6 2304,0 3050,0 500 kcmil 37141 4 G 25 31,0 960,0 1950,0 4
37115 1 x 300 33,5 2880,0 3700,0 600 kcmil 37142 4 G 35 35,0 1344,0 2650,0 2
37116 2 x 1,5 8,5 29,0 130,0 16 37143 4 G 50 41,0 1920,0 3600,0 1
37117 2 x 2,5 10,2 48,0 190,0 14 37144 4 G 70 46,5 2688,0 4890,0 2/0
37118 2x4 11,8 77,0 260,0 12 37145 4 G 95 51,6 3648,0 6180,0 3/0
37119 2x6 13,1 115,0 350,0 10 37146 4 G 120 56,1 4608,0 7200,0 4/0
37120 2 x 10 17,7 192,0 550,0 8 37147 5 G 1,5 11,2 72,0 225,0 16
37121 2 x 16 20,2 307,0 900,0 6 37148 5 G 2,5 13,3 120,0 335,0 14
37122 2 x 25 24,3 480,0 1300,0 4 37149 5G4 15,6 192,0 470,0 12
37123 3 G 1,5 9,5 43,0 150,0 16 37150 5G6 17,5 288,0 645,0 10
37124 3 G 2,5 11,0 72,0 205,0 14 37151 5 G 10 22,9 480,0 1150,0 8
37125 3G4 13,0 115,0 330,0 12 37152 5 G 16 26,4 768,0 1690,0 6
37126 3G6 14,5 173,0 470,0 10 37153 5 G 25 32,0 1200,0 2400,0 4
270
Water resistant Cables
Application
Tauchflex-FL is a special cable for use as a connecting and control cable for submersible motor pumps, underwater floodlights, floating switch and
has proven its worth for constant use in drinking water, process water and service water up to an immersion depth of 300 m.
Tauchflex-FL can also be installed for use in dry, damp and humid areas as well as in the open air. Not suitable for the installation in hazardous areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight approx. cross-sec. dimension weight approx.
mm approx. mm kg / km kg / km mm approx. mm kg / km kg / km
37155 3 x 1,5 7,0 x 13,0 43,0 125,0 16 37167 4 G 1,5 7,0 x 17,0 58,0 160,0 16
37156 3 x 2,5 8,0 x 16,0 72,0 185,0 14 37168 4 G 2,5 8,0 x 20,0 96,0 245,0 14
37157 3x4 9,0 x 19,0 115,0 290,0 12 37169 4G4 9,0 x 24,0 154,0 330,0 12
37158 3x6 10,0 x 23,0 173,0 400,0 10 37170 4G6 10,0 x 26,0 230,0 450,0 10
37159 3 x 10 12,0 x 28,0 288,0 615,0 8 37171 4 G 10 11,0 x 31,0 384,0 850,0 8
37160 3 x 16 14,0 x 31,0 461,0 890,0 6 37172 4 G 16 13,0 x 36,0 614,0 1200,0 6
37161 3 x 25 17,0 x 37,0 720,0 1155,0 4 37173 4 G 25 15,0 x 45,0 960,0 1590,0 4
37162 3 x 35 17,0 x 38,0 1008,0 1540,0 2 37174 4 G 35 17,0 x 48,0 1344,0 2085,0 2
37163 3 x 50 20,0 x 45,0 1440,0 2190,0 1 37175 4 G 50 20,0 x 59,0 1920,0 2890,0 1
37164 3 x 70 22,0 x 52,0 2016,0 2890,0 2/0
37165 3 x 95 25,0 x 58,0 2736,0 3800,0 3/0
37166 3 x 120 27,0 x 64,0 3456,0 4700,0 4/0
271
Water resistant Cables
Application
Specifically designed for use in fresh water up to 10 m water depth and a maximum water temperature of 40C for connection of submersible pumps
and similar applications. Not suitable for underwater power transmission systems or in waterways or in areas where mechanical damage is possible
which represent a potential danger.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
37287 1 x 1,5 5,7 - 7,1 14,4 58,0 16 37323 3 G 70 38,4 - 48,3 2016,0 3400,0 2/0
37288 1 x 2,5 6,3 - 7,9 24,0 71,0 14 37324 3 G 95 43,3 - 54,0 2736,0 4450,0 3/0
37289 1x4 7,2 - 9,0 38,0 100,0 12 37325 3 G 120 47,4 - 60,0 3456,0 5180,0 4/0
37290 1x6 7,9 - 9,8 58,0 130,0 10 37326 3 G 150 52,0 - 66,0 4320,0 6500,0 300 kcmil
37291 1 x 10 9,5 - 11,9 96,0 230,0 8 37327 3 G 185 57,0 - 72,0 5328,0 7860,0 350 kcmil
37292 1 x 16 10,8 - 13,4 154,0 290,0 6 37328 3 G 240 65,0 - 82,0 6192,0 10224,0 500 kcmil
37293 1 x 25 12,7 - 15,8 240,0 420,0 4 37329 3 G 300 72,0 - 90,0 8640,0 12620,0 600 kcmil
37294 1 x 35 14,3 - 17,9 336,0 530,0 2 37330 4G1 9,2 - 11,9 38,0 150,0 18
37295 1 x 50 16,5 - 20,6 480,0 750,0 1 37331 4 G 1,5 10,2 - 13,1 58,0 200,0 16
37296 1 x 70 18,6 - 23,3 672,0 960,0 2/0 37332 4 G 2,5 12,1 - 15,5 96,0 290,0 14
37297 1 x 95 20,8 - 26,0 912,0 1250,0 3/0 37333 4G4 14,0 - 17,9 154,0 395,0 12
37298 1 x 120 22,8 - 28,6 1152,0 1560,0 4/0 37334 4G6 15,7 - 20,0 230,0 540,0 10
37299 1 x 150 25,2 - 31,4 1440,0 1900,0 300 kcmil 37335 4 G 10 20,9 - 26,5 384,0 950,0 8
37300 1 x 185 27,6 - 34,4 1776,0 2300,0 350 kcmil 37336 4 G 16 23,8 - 30,1 614,0 1260,0 6
37301 1 x 240 30,6 - 38,3 2304,0 2950,0 500 kcmil 37337 4 G 25 28,9 - 36,6 960,0 1860,0 4
37302 1 x 300 33,5 - 41,9 2880,0 3600,0 600 kcmil 37338 4 G 35 32,5 - 41,1 1344,0 2380,0 2
37303 1 x 400 37,4 - 46,8 3840,0 4600,0 750 kcmil 37339 4 G 50 37,7 - 47,5 1920,0 3190,0 1
37304 1 x 500 41,3 - 52,0 4800,0 6000,0 1000 kcmil 37340 4 G 70 42,7 - 54,0 2688,0 4260,0 2/0
37305 2x1 7,7 - 10,0 19,0 98,0 18 37341 4 G 95 48,4 - 61,0 3648,0 5600,0 3/0
37306 2 x 1,5 8,5 - 11,0 29,0 135,0 16 37342 4 G 120 53,0 - 66,0 4608,0 6830,0 4/0
37307 2 x 2,5 10,2 - 13,1 48,0 193,0 14 37343 4 G 150 58,0 - 73,0 5760,0 8320,0 300 kcmil
37308 2x4 11,8 - 15,1 77,0 280,0 12 37344 4 G 185 64,0 - 80,0 7104,0 9800,0 350 kcmil
37309 2x6 13,1 - 16,8 115,0 330,0 10 37345 4 G 240 72,0 - 91,0 9216,0 12100,0 500 kcmil
37310 2 x 10 17,7 - 22,6 192,0 586,0 8 37346 4 G 300 80,0 - 101,0 11520,0 15200,0 600 kcmil
37311 2 x 16 20,2 - 25,7 307,0 810,0 6 37354 5G1 10,2 - 13,1 48,0 175,0 18
37312 2 x 25 24,3 - 30,7 480,0 1160,0 4 37347 5 G 1,5 11,2 - 14,4 72,0 240,0 16
37313 3G1 8,3 - 10,7 29,0 130,0 18 37348 5 G 2,5 13,3 - 17,0 120,0 345,0 14
37314 3 G 1,5 9,2 - 11,9 43,0 165,0 16 37349 5G4 15,6 - 19,9 192,0 485,0 12
37315 3 G 2,5 10,9 - 14,0 72,0 235,0 14 37350 5G6 17,5 - 22,2 288,0 650,0 10
37316 3G4 12,7 - 16,2 115,0 320,0 12 37351 5 G 10 22,9 - 29,1 480,0 1200,0 8
37317 3G6 14,1 - 18,0 173,0 420,0 10 37352 5 G 16 26,4 - 33,3 768,0 1550,0 6
37318 3 G 10 19,1 - 24,2 288,0 810,0 8 37353 5 G 25 32,0 - 40,4 1200,0 2250,0 4
37319 3 G 16 21,8 - 27,6 461,0 1050,0 6 37355 6 G 1,5 13,4 - 17,2 87,0 171,0 16
37320 3 G 25 26,1 - 33,0 720,0 1250,0 4 37356 6 G 2,5 15,7 - 20,0 144,0 279,0 14
37321 3 G 35 29,3 - 37,1 1008,0 1900,0 2 37357 12 G 1,5 17,6 - 22,4 173,0 340,0 16
37322 3 G 50 34,1 - 42,9 1440,0 2600,0 1 37358 12 G 2,5 20,6 - 26,2 288,0 571,0 14
272
FLAT & RIBBON CABLES
3
in
E
VD eld 29
ng
x
xe
ex
VD
ed
U
R/ shi E 0
xi
- fi
- fl
./
0 /
le
ed
i
no
H A ed / VD
-f
-f
U
C)
C)
ge
us
us
CS REG
e n es /
(
e
lta
di
di
se
re
re
t
fre
ut tan
r
n
ra
ra
co
tu
tu
u
vo
E
ai
n-
or
sis
ra
ra
A
d
ch
al
ge
in
in
pe
pe
re
do
re
in
ge
nd
nd
ag
lo
lo
re
V-
m
L/
om
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
N
Flat & ribbon cables
275
Flat and Ribbon Cables
Note
Part no. 27012 (6x4).
G = with green-yellow conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
PVC type of flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this
purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface
of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded successively
so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5 mm, is very critical due to its low tensile stress. In such case, you should
add 10% reserve wire for calculation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight approx. cross-sec. dimension weight approx.
mm approx. mm kg / km kg / km mm approx. mm kg / km kg / km
26980 4 G 0,75 4,3 x 12,6 28,8 90,0 19 27006 12 G 1,5 4,5 x 38,9 173,0 421,0 16
26981 5 G 0,75 4,3 x 16,1 36,0 115,0 19 27028 16 G 1,5 4,5 x 51,5 230,4 555,0 16
26982 6 G 0,75 4,3 x 19,4 43,2 141,0 19 27030 24 G 1,5 4,5 x 83,0 346,0 820,0 16
26983 9 G 0,75 4,3 x 26,4 64,8 198,0 19 27007 4 G 2,5 5,5 x 17,0 96,0 205,0 14
26984 10 G 0,75 4,3 x 30,1 72,0 224,0 19 27008 5 G 2,5 5,5 x 21,5 120,0 256,0 14
26985 12 G 0,75 4,3 x 33,8 84,4 258,0 19 27009 7 G 2,5 5,5 x 30,3 168,0 344,0 14
26986 16 G 0,75 4,3 x 44,4 115,2 340,0 19 27010 8 G 2,5 5,5 x 31,9 192,0 389,0 14
26987 18 G 0,75 4,3 x 49,2 129,6 380,0 19 27011 12 G 2,5 5,8 x 47,1 288,0 580,0 14
26988 20 G 0,75 4,3 x 55,0 144,0 424,0 19 27029 16 G 2,5 5,8 x 55,1 384,0 674,0 14
26989 24 G 0,75 4,3 x 65,6 172,8 509,0 19 27012 24 G 2,5 15,0 x 63,0 604,0 950,0 14
26990 3G1 4,5 x 10,8 28,8 80,0 18 27027 24 G 2,5 5,8 x 120,0 604,0 950,0 14
26991 4G1 4,5 x 13,4 38,4 104,0 18 27013 4G4 7,0 x 21,8 154,0 344,0 12
26992 5G1 4,5 x 16,0 48,0 134,0 18 27014 5G4 7,0 x 27,4 192,0 428,0 12
26993 6G1 4,5 x 20,6 57,6 161,0 18 27015 7G4 7,9 x 36,6 269,0 590,0 12
26994 9G1 4,5 x 28,4 86,4 230,0 18 27016 4G6 8,2 x 24,8 230,0 424,0 10
26995 10 G 1 4,5 x 30,0 96,0 256,0 18 27017 5G6 8,2 x 31,8 288,0 530,0 10
26996 12 G 1 4,5 x 36,2 115,2 298,0 18 27018 7G6 8,2 x 42,6 403,0 760,0 10
26997 16 G 1 4,5 x 47,6 153,6 395,0 18 27019 4 G 10 10,0 x 29,6 384,0 710,0 8
26998 18 G 1 4,5 x 52,8 172,8 441,0 18 27020 4 G 16 11,2 x 34,4 614,0 1014,0 6
26999 20 G 1 4,5 x 59,0 192,0 495,0 18 27025 5 G 16 13,0 x 46,6 768,0 1370,0 6
27000 24 G 1 4,5 x 70,4 230,4 590,0 18 27021 4 G 25 13,7 x 42,6 960,0 1365,0 4
27001 4 G 1,5 4,5 x 13,7 58,0 133,0 16 27026 5 G 25 15,5 x 55,5 1200,0 2000,0 4
27002 5 G 1,5 4,5 x 17,9 72,0 169,0 16 27022 4 G 35 15,4 x 47,6 1344,0 2100,0 2
27003 7 G 1,5 4,5 x 23,5 101,0 235,0 16 27023 4 G 50 18,2 x 57,0 1920,0 2940,0 1
27004 8 G 1,5 4,5 x 26,8 115,0 265,0 16 27024 4 G 70 20,0 x 64,2 2688,0 4090,0 2/0
27005 10 G 1,5 4,5 x 33,5 144,0 332,0 16
276
Flat and Ribbon Cables
NEO-Flat (N)GFLGU
Application
Neoprene type of flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units. These cables are
also available for export with UL-approval on request.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this
purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface
of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded successively
so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5 mm, is very critical due to its low tensile stress. In such case, you should
add 10% reserve wire for calculation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight approx. cross-sec. dimension weight approx.
mm approx. mm kg / km kg / km mm approx. mm kg / km kg / km
28001 4 G 1,5 5,9 x 16,2 58,0 234,0 16 28022 4 G 16 11,6 x 35,6 614,0 1430,0 6
28002 5 G 1,5 5,9 x 23,7 72,0 304,0 16 28023 5 G 16 12,2 x 48,2 768,0 1590,0 6
28003 7 G 1,5 5,9 x 30,5 101,0 391,0 16 28024 4 G 25 14,1 x 45,8 960,0 1890,0 4
28004 8 G 1,5 5,9 x 34,0 115,0 441,0 16 28025 5 G 25 14,7 x 58,3 1200,0 2215,0 4
28005 10 G 1,5 5,9 x 43,5 144,0 460,0 16 28026 7 G 25 15,3 x 78,7 1680,0 3000,0 4
28006 12 G 1,5 6,5 x 50,4 173,0 646,0 16 28027 4 G 35 15,8 x 50,8 1344,0 2460,0 2
28007 24 G 1,5 (6 x 4) 13,0 x 56,0 346,0 1290,0 16 28028 5 G 35 16,4 x 64,4 1680,0 2880,0 2
28008 4 G 2,5 7,2 x 19,6 96,0 316,0 14 28029 7 G 35 16,4 x 86,4 2352,0 4100,0 2
28009 5 G 2,5 7,2 x 27,8 120,0 391,0 14 28030 4 G 50 18,6 x 60,2 1920,0 3385,0 1
28010 7 G 2,5 7,2 x 36,1 168,0 533,0 14 28031 4 G 70 21,0 x 68,0 2688,0 4480,0 2/0
28011 8 G 2,5 7,2 x 40,2 192,0 602,0 14 28032 4 G 95 24,1 x 78,6 3648,0 5990,0 3/0
28012 12 G 2,5 7,8 x 59,4 288,0 890,0 14 28033 4 G 120 25,5 x 84,2 4608,0 7240,0 4/0
28013 24 G 2,5 (6 x 4) 15,5 x 66,8 576,0 1480,0 14
28014 4G4 8,8 x 24,2 154,0 506,0 12
28015 5G4 8,8 x 33,4 192,0 621,0 12
28016 7G4 8,8 x 42,5 269,0 851,0 12
28017 4G6 9,6 x 27,4 230,0 661,0 10
28018 5G6 9,6 x 37,4 288,0 740,0 10
28019 7G6 9,6 x 47,2 403,0 1004,0 10
28020 4 G 10 10,4 x 30,8 384,0 1027,0 8
28021 5 G 10 10,4 x 41,6 480,0 1171,0 8
277
Flat and Ribbon Cables
Application
PVC screened flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this
purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface
of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded successively
so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5 mm, is very critical due to its low tensile stress. In such case, you should
add 10% reserve wire for calculation.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
278
Flat and Ribbon Cables
Note
G = with green-yellow conductor J
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
Neoprene screened flat cables are used mainly as trailing cable for crane installations, floor conveyer systems and shelf control units. These cables are
also available for export with UL-approval on request.
Installation notes
Cables reels with flat cables must be transported in standing position on the flange. A bending flexibility can be achieved on a plane surface. For this
purpose, the corresponding fitting instructions should be followed.
Put the cable trolly on the guiding rail or upon carrier beam and push them together at the starting point. The distance between the bedding surface
of two cable trollys must be wider than the double thickness of a cable-packet.
During the packeting performance, it must be started with the smaller cross-section which lays on the bedding surface and will be builded successively
so that the biggest cross-section is laying on the top.
Further, be careful of a symmetrical load distribution.
In case of multicore flat cables with small cross-section, smaller than 2,5 mm, is very critical due to its low tensile stress. In such case, you should
add 10% reserve wire for calculation.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight approx. cross-sec. dimension weight approx.
mm approx. mm kg / km kg / km mm approx. mm kg / km kg / km
28100 8 G 1,5 7,9 x 42,0 231,0 520,0 16 28103 6 G 2,5 8,5 x 34,5 247,0 540,0 14
28101 12 G 1,5 7,9 x 61,0 346,0 790,0 16 28104 12 G 2,5 8,9 x 68,0 494,0 1000,0 14
28102 4 G 2,5 8,5 x 25,5 164,0 420,0 14 28302 4 G 25 16,0 x 51,0 1116,0 1650,0 4
279
Flat and Ribbon Cables
Application
Ribbon cables are used as connecting and control cables wherever there is a need to install quickly and with a minimum waste of space. These cables
offer an excellent degree of flexibility.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Typ L (colour coded) Typ L AWG 28 (single coloured, edge marking on one side)
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
44001 2 x 0,14 3,9 x 1,4 2,7 7,0 26 44041 10 x 0,08 12,7 x 0,9 13,4 30,0 28
44002 3 x 0,14 6,4 x 1,4 4,0 11,0 26 44042 14 x 0,08 17,8 x 0,9 18,0 50,0 28
44003 4 x 0,14 8,9 x 1,4 5,4 14,0 26 44043 16 x 0,08 20,3 x 0,9 20,0 53,0 28
44004 5 x 0,14 11,3 x 1,4 6,7 18,0 26 44044 20 x 0,08 25,4 x 0,9 25,0 65,0 28
44005 6 x 0,14 13,9 x 1,4 8,1 21,0 26 44045 26 x 0,08 33,0 x 0,9 32,0 75,0 28
44006 7 x 0,14 16,4 x 1,4 9,4 25,0 26 44046 34 x 0,08 43,2 x 0,9 43,0 90,0 28
44007 8 x 0,14 18,9 x 1,4 10,7 28,0 26 44047 40 x 0,08 50,8 x 0,9 48,0 125,0 28
44008 9 x 0,14 21,4 x 1,4 13,4 32,0 26 44048 48 x 0,08 61,0 x 0,9 59,0 145,0 28
44009 10 x 0,14 23,9 x 1,4 14,4 35,0 26
44010 11 x 0,14 26,4 x 1,4 15,3 39,0 26 Typ D (colour coded)
44011 12 x 0,14 28,9 x 1,4 16,1 42,0 26 Part no. No.cores x Outer Cop. Weight AWG-No.
44012 16 x 0,14 38,9 x 1,4 21,5 56,0 26 cross-sec. approx. mm weight approx.
44013 20 x 0,14 48,9 x 1,4 27,0 70,0 26 mm kg / km kg / km
44014 4 x 0,25 9,1 x 1,6 9,6 21,0 24 44049 2 x 0,5 3,9 x 1,4 10,0 10,0 20
44015 5 x 0,25 11,6 x 1,6 12,0 26,0 24 44050 3 x 0,5 6,4 x 1,4 14,0 14,0 20
44016 6 x 0,25 14,1 x 1,6 14,4 31,0 24 44051 4 x 0,5 8,9 x 1,4 19,0 17,0 20
44017 7 x 0,25 16,6 x 1,6 16,8 36,0 24 44052 5 x 0,5 11,4 x 1,4 24,0 21,0 20
44018 8 x 0,25 19,1 x 1,6 19,2 42,0 24 44053 6 x 0,5 13,9 x 1,4 29,0 25,0 20
44019 10 x 0,25 24,1 x 1,6 24,0 52,0 24 44054 7 x 0,5 16,4 x 1,4 34,0 29,0 20
44020 12 x 0,25 29,1 x 1,6 28,8 62,0 24 44055 8 x 0,5 18,9 x 1,4 38,0 33,0 20
44021 16 x 0,25 39,1 x 1,6 38,4 83,0 24 44056 9 x 0,5 21,4 x 1,4 42,0 37,0 20
44022 20 x 0,25 49,1 x 1,6 48,0 104,0 24 44057 10 x 0,5 23,9 x 1,4 48,0 41,0 20
44023 4 x 0,5 9,0 x 2,0 19,2 38,0 20 44058 11 x 0,5 26,4 x 1,4 56,0 47,0 20
44024 5 x 0,5 12,0 x 2,0 24,0 48,0 20
44025 6 x 0,5 15,0 x 2,0 28,8 57,0 20
44026 7 x 0,5 17,0 x 2,0 33,6 66,0 20
44027 8 x 0,5 20,0 x 2,0 38,4 76,0 20
44028 10 x 0,5 23,0 x 2,0 48,0 95,0 20
44029 12 x 0,5 30,0 x 2,0 58,0 114,0 20
44030 16 x 0,5 40,0 x 2,0 77,0 151,0 20
44031 20 x 0,5 50,0 x 2,0 101,0 190,0 20
44032 4 x 0,75 10,6 x 2,5 29,0 52,0 19
44033 5 x 0,75 13,3 x 2,5 36,0 64,0 19
44034 6 x 0,75 16,0 x 2,5 43,2 77,0 19
44035 7 x 0,75 18,7 x 2,5 50,0 90,0 19
44036 8 x 0,75 21,4 x 2,5 58,0 103,0 19
44037 10 x 0,75 26,8 x 2,5 72,0 130,0 19
44038 12 x 0,75 32,2 x 2,5 86,0 155,0 19
44039 16 x 0,75 43,0 x 2,5 112,0 206,0 19
44040 20 x 0,75 53,4 x 2,5 151,0 260,0 19
280
Flat and Ribbon Cables
J
Minimum bending radius
15x cable
Radiation resistance
up to 80x106 cJ/kg (up to 80 Mrad)
Application
TUBEFLEX-Y Flat ribbon cable, due to its roundshape offers considerable advantages compared with other flat ribbon cables during the installation
and assembly. This roundshaped cable bids enormous profits by using the quick and economical possibilities under continuance with the efficient
connection in IDC-technique. All conductors can be contacted at one working procedure without stripping the insulation. The accurate to size
pitch-image of the ribbon cable is obtained due to an adapted backshaping before the plug installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part No.cores Flat ribbon Outer Outer Cop. Weight Part No.cores Flat ribbon Outer Outer Cop. Weight
no. x AWG-No. dimension sheath approx. weight approx. no. x AWG-No. dimension sheath approx. weight approx.
Width mm nominal mm kg / km kg / km Width mm nominal mm kg / km kg / km
wall- wall-
thickness thickness
mm mm
45130 9 x 28 11,43 0,8 6,1 8,7 35,0 45138 30 x 28 38,10 0,8 9,0 29,0 81,0
45131 10 x 28 12,70 0,8 6,2 9,7 36,0 45139 34 x 28 43,20 0,8 10,0 32,9 87,0
45132 14 x 28 17,78 0,8 7,2 13,6 48,0 45140 36 x 28 45,72 0,8 10,2 34,9 91,0
45133 16 x 28 20,30 0,8 7,2 15,5 51,0 45141 37 x 28 47,00 1,0 10,3 35,8 93,0
45134 20 x 28 25,40 0,8 7,3 19,4 57,0 45142 40 x 28 50,80 1,0 10,7 38,7 101,0
45135 24 x 28 30,48 0,8 8,6 23,2 66,0 45143 50 x 28 63,50 1,0 11,1 48,4 118,0
45136 25 x 28 31,75 0,8 8,6 24,2 69,0 45144 60 x 28 76,20 1,0 12,5 58,1 135,0
45137 26 x 28 33,02 0,8 8,6 25,2 70,0 45145 64 x 28 81,30 1,0 13,0 62,0 147,0
281
Flat and Ribbon Cables
Application
TUBEFLEX-(St)-CY Flat ribbon cable, due to its roundshape offers considerable advantages compared with other flat ribbon cables during the installation
and assembly. This roundshaped cable bids enormous profits by using the quick and economical possibilities under continuance with the efficient
connection in IDC-technique. All conductors can be contacted at one working procedure without stripping the insulation. The accurate to size
pitch-image of the ribbon cable is obtained due to an adapted backshaping before the plug installation.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part No.cores Flat ribbon Outer Outer Cop. Weight Part No.cores Flat ribbon Outer Outer Cop. Weight
no. x AWG-No. dimension sheath approx. weight approx. no. x AWG-No. dimension sheath approx. weight approx.
Width mm nominal mm kg / km kg / km Width mm nominal mm kg / km kg / km
wall- wall-
thickness thickness
mm mm
45150 9 x 28 11,43 0,8 6,3 30,9 56,0 45161 37 x 28 47,00 1,0 10,5 71,1 128,0
45151 10 x 28 12,70 0,8 6,4 31,9 57,0 45162 40 x 28 50,80 1,0 11,3 74,1 135,0
45152 14 x 28 17,78 0,8 7,2 35,6 70,0 45163 50 x 28 63,50 1,0 11,6 88,3 160,0
45153 16 x 28 20,30 0,8 7,4 42,0 75,0 45164 60 x 28 76,20 1,0 12,9 98,7 172,0
45154 20 x 28 25,40 0,8 7,8 45,8 83,0 45165 64 x 28 81,30 1,0 13,3 107,2 192,0
45155 24 x 28 30,48 0,8 9,0 54,3 97,0
45156 25 x 28 31,75 0,8 9,0 55,2 100,0
45157 26 x 28 33,02 0,8 9,0 60,0 101,0
45158 30 x 28 38,10 0,8 9,2 60,4 113,0
45159 34 x 28 43,20 0,8 10,2 68,1 122,0
45160 36 x 28 45,72 0,8 10,4 70,1 126,0
282
SINGLE CONDUCTORS
3
in
E
VD eld 29
ng
x
xe
ex
VD
d
U
R/ shi E 0
xi
- fi
- fl
xe
./
0 /
le
ed
i
no
H A ed / VD
-f
f
U
C)
C)
s-
ge
us
CS REG
e n es /
(
e
lta
di
di
se
re
re
t
V- -fre
ut tan
r
n
ra
ra
co
tu
tu
u
vo
E
ai
or
sis
ra
ra
n
g
A
d
ch
al
ge
in
in
pe
pe
re
do
re
in
ge
nd
nd
ag
lo
lo
re
m
L/
om
Ha
Co
Pa
Be
Be
Dr
Sc
Te
Te
O
U
U
N
Single Conductors
HELUTHERM 400
-60 to +400 500 15x 15x X X 312
TOPFLEX 300
-5 to +80 -40 to +80 0,6/1kV 7,5x 7,5x (X) X 321
KOMPOSPEED 600 / 600-C -30 to +90 -40 to +100 0,6/1kV 5/7,5x 3/4x X X X X /X 322
285
SELECTION TABLE - DRAG CHAIN CABLES
ng
in
xi
g
/s 2
ce
fle
in
/
an
ex
ge U
(m
-
es ist
lta 0 /
- fl
us
)
-c t d
vo U
/s
di
io
)
C)
g ge
en
(m
ra
at
or
(
tin lta
er
m
re
in
s
25
e
el
nt
ra vo
ee
le
ui CSA
ov
nd
tu
s
c
yc
)
al
to
le
sp
ac
pe l
ra
ia
m
O ina
be
ov
r
.c
up
va
te
eq L/
er
pe
.
ge
.
ax
ax
ou
pr
ax
ax
m
om
.
at
in
U
m
=
Ap
M
M
0
Pa
M
M
M
M
(D
(1
Te
N
Single cores for drag chain cables
KOMPOSPEED 600 100 5xD 4 10 11 Mio Poly/ Poly 600/1000V -30 to +90 322 504
KOMPOSPEED 600-C
100 7.5 x D 4 10 11 Mio Poly/CU/Poly 600/1000V -30 to +90 322 505
TOPFLEX 300 5 7.5 x D 2 10 9 Mio PVC/PVC 600/1000V -5 to +80 321 500
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).
286
Single Conductors
Application
PVC insulated flexible hook-up wires are used for the connection for low voltage applications, communication apparatus, electronic assemblies and
equipment, racks, switchboards etc. correspondingly of VDE 0800 part 1 for the temperature range up to +70C. Those stranded hook-up wires are
not permitted to install for heavy current application outside of the equipment.
K
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
LiYv
Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
sec. approx. mm weight
mm kg / km
approx. RAL 9005 - 5015 8003 3000 9003 7000 4005 1021 3015 6018 - 5010 2003 - -
Continuation
287
Single Conductors
288
Single Conductors
Continuation
289
Single Conductors
290
Single Conductors
Application
K
These single cores are suitable for laying in tubes, under and surface mounting of plasters and also in closed installation conduits. These are not allowed
to install for direct laying on cable trays, channels or tanks. These types are permitted for the inner wiring of equipment, distributor and switchboards
and also for protective laying to the lightings with a nominal voltage up to 1000 V alternating current or up to 750 V direct current against earth.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H07V-K, (H)07V-K
Cross- Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG 2-col. U-BU
sec. min. - max. weight
mm mm kg / km
approx. RAL 9005 - 5015 8003 3000 9003 7001 4005 1021 3015 6018 - 5010 2003 - 5002
Continuation
291
Single Conductors
Packing Drum
H07V-K drum
Part no. 26825 26826 26827 26828 26829 26830 26831 26832 26833 26834 26835 26836 26837 26838 26840 -
10 5,7 - 6,8 96,0
Part no. 26841 26842 26843 26844 26845 26846 26847 26848 26849 26850 26851 26852 26853 26854 26856 -
16 6,7 - 8,1 154,0
Part no. 26857 26858 26859 26860 26861 26862 26863 26864 26865 26866 26867 26868 26869 26870 26872 -
25 8,4 - 10,2 240,0
Part no. 26873 26874 26875 26876 26877 26878 26879 26880 26881 26882 26883 26884 26885 26886 26888 -
35 9,7 - 11,7 336,0
Part no. 26889 26890 26891 26892 26893 26894 26895 26896 26897 26898 26899 26900 26901 26902 26904 -
50 11,5 - 13,9 480,0
Part no. 26905 26906 26907 26908 26909 26910 26911 26912 26913 26914 26915 26916 26917 26918 26920 -
70 13,2 - 16,0 672,0
Part no. 26921 26922 26923 26924 26925 26926 26927 26928 26929 26930 26931 26932 26933 26934 26936 -
95 15,1 - 18,2 912,0
Part no. 29305 29306 29307 29308 29309 29310 29311 29312 29313 29314 29315 29316 29317 29318 29320 -
120 16,7 - 20,2 1152,0
Part no. 29321 29322 29323 29324 29325 29326 29327 29328 29329 29330 29331 29332 29333 29334 29336 -
150 18,6 - 22,5 1440,0
Part no. 29337 29338 29339 29340 29341 29342 29343 29344 29345 29346 29347 29348 29349 29350 29352 -
185 20,6 - 24,9 1776,0
Part no. 29353 29354 29355 29356 29357 29358 29359 29360 29361 29362 29363 29364 29365 29366 29368 -
240 23,5 - 28,4 2304,0
292
Single Conductors
2,4 - 2,8
7,2
9,6
29753 29754 29755 29756 K
Packing Spool (with various capacity)
(H)07V-K spool
Part no. 29757 29758 29759 29760
1,5 2,8 - 3,4 14,4
Part no. 29761 29762 29763 29764
2,5 3,4 - 4,1 24,0
Part no. 29765 29766 29767 29768
4 3,9 - 4,8 38,0
Part no. 29769 29770 29771 29772
6 4,4 - 5,3 58,0
Part no. 29773 29774 29775 29776
10 5,7 - 6,8 96,0
293
Single Conductors
Packing Drum
H07V-U drum
Part no. 28145 28146 28147 28148 28149 28150 28151 28152 - - - - - - - -
1,5 2,6 - 3,2 14,4
Part no. 28153 28154 28155 28156 28157 28158 28159 28160 - - - - - - - -
2,5 3,2 - 3,9 24,0
Part no. 28161 28162 28163 28164 28165 28166 28167 28168 - - - - - - - -
4 3,6 - 4,4 38,0
Part no. 28169 28170 28171 28172 28173 28174 28175 28176 - - - - - - - -
6 4,1 - 5,0 58,0
Part no. 28177 28178 28179 28180 28181 28182 28183 28184 - - - - - - - -
10 5,3 - 6,4 96,0
294
Single Conductors
Packing Drum
H07V-R drum
Part no. 28185 28186 28187 28188 28189 28190 28191 28192 - - - - - - - -
16 6,4 - 7,8 154,0
Part no. 28193 28194 28195 28196 28197 - - - - - - - - - - -
25
Part no.
8,1 - 9,7 240,0
28198 28199 28200 28201 28202 - - - - - - - - - - -
K
35 9,0 - 10,9 336,0
Part no. 28203 28204 28205 28206 28207 - - - - - - - - - - -
50 10,6 - 12,8 480,0
Part no. 28208 28209 28210 28211 28212 - - - - - - - - - - -
70 12,1 - 14,6 672,0
Part no. 28213 28214 28215 28216 28217 - - - - - - - - - - -
95 14,1 - 17,1 912,0
Part no. 28218 28219 28220 28221 28222 - - - - - - - - - - -
120 15,6 - 18,8 1152,0
Part no. 28223 28224 28225 28226 28227 - - - - - - - - - - -
150 17,3 - 20,9 1440,0
Part no. 28228 28229 28230 28231 28232 - - - - - - - - - - -
185 19,3 - 23,3 1776,0
Part no. 28233 28234 28235 28236 28237 - - - - - - - - - - -
240 22,0 - 26,6 2304,0
295
H05V-K, H07V-K
PVC-Single Cores
296
Single Conductors
TOPFLEX 303 X07V-K-Y double insulation 0,6/1kV flexible PVC single core,
oil resistant
Application
This cable is used for conditions of increased mechanical stress. For flexible use with free movement without tensile stress or forced movements in
dry, moist and wet environments, but not suitable for use outdoors. The cable may be laid in trays, troughs and channels.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
core-/sheath-color black/grey core-/sheath-color green-yellow/grey
K
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
75460 1x6 6,0 58,0 84,0 10 75449 1G6 6,0 57,6 84,0 10
75461 1 x 10 9,5 96,0 143,0 8 75469 1 G 10 9,5 96,0 143,0 8
75462 1 x 16 10,3 154,0 209,0 6 73859 1 G 16 10,3 154,0 209,0 6
75463 1 x 25 11,1 240,0 308,0 4 75470 1 G 25 11,1 240,0 325,0 4
75464 1 x 35 15,0 336,0 440,0 2 75471 1 G 35 15,0 336,0 440,0 2
75465 1 x 50 17,5 480,0 572,0 1 75472 1 G 50 17,5 480,0 572,0 1
75466 1 x 70 20,0 672,0 792,0 2/0 75473 1 G 70 20,0 672,0 792,0 2/0
75467 1 x 95 22,0 912,0 1155,0 3/0 75474 1 G 95 22,0 912,0 1155,0 3/0
72184 1 x 120 23,5 1152,0 1267,0 4/0 75475 1 G 120 23,5 1152,0 1267,0 4/0
72185 1 x 150 26,5 1440,0 1650,0 300 kcmil 75476 1 G 150 26,5 1440,0 1650,0 300 kcmil
75468 1 x 185 29,0 1776,0 2134,0 350 kcmil 75477 1 G 185 29,0 1776,0 2134,0 350 kcmil
74221 1 x 240 31,0 2304,0 2943,0 500 kcmil 75478 1 G 240 31,0 2304,0 2943,0 500 kcmil
72082 1 x 300 35,0 2880,0 3600,0 600 kcmil 75479 1 G 300 35,0 2280,0 3600,0 600 kcmil
297
Single Conductors
Application
The LifY single cores are used as super flexible insulated strand wires for switch cabinets, as measuring cable for testing, laboratories, research etc.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Core Cross- Cond. Outer Cop. Weight AWG-No. Part no. Core Cross- Cond. Outer Cop. Weight AWG-No.
colour sec. make-up approx. weight approx. colour sec. make-up approx. weight approx.
mm (nom. val.) mm kg / km kg / km mm (nom. val.) mm kg / km kg / km
n x wire n x wire
151xx - 0,1 51 x 0,05 1,0 1,2 2,1 - 15097 BK 35 4508 x 0,1 11,7 336,0 380,0 2
152xx - 0,14 72 x 0,05 1,0 1,4 2,6 26 15139 GN-YE 35 4508 x 0,1 11,7 336,0 380,0 2
153xx - 0,25 65 x 0,07 1,3 2,5 4,2 24 15127 BU 35 4508 x 0,1 11,7 336,0 380,0 2
154xx - 0,5 132 x 0,07 2,0 5,5 8,0 20 15128 BN 35 4508 x 0,1 11,7 336,0 380,0 2
155xx - 0,75 195 x 0,07 2,2 8,0 12,0 18 15126 RD 35 4508 x 0,1 11,7 336,0 380,0 2
156xx - 1 260 x 0,07 2,5 10,8 18,0 17 15098 BK 50 6468 x 0,1 14,7 480,0 521,0 1
157xx - 1,5 192 x 0,1 3,5 15,0 22,0 16 15140 GN-YE 50 6468 x 0,1 14,7 480,0 521,0 1
158xx - 2,5 320 x 0,1 3,8 25,0 37,0 14 15130 BU 50 6468 x 0,1 14,7 480,0 521,0 1
159xx - 4 512 x 0,1 4,9 40,0 50,0 12 15131 BN 50 6468 x 0,1 14,7 480,0 521,0 1
15093 BK 6 768 x 0,1 6,0 60,0 71,0 10 15129 RD 50 6468 x 0,1 14,7 480,0 521,0 1
15135 GN-YE 6 768 x 0,1 6,0 60,0 71,0 10 15099 BK 70 8967 x 0,1 15,5 672,0 740,0 2/0
15115 BU 6 768 x 0,1 6,0 60,0 71,0 10 15141 GN-YE 70 8967 x 0,1 15,5 672,0 740,0 2/0
15116 BN 6 768 x 0,1 6,0 60,0 71,0 10 15133 BU 70 8967 x 0,1 15,5 672,0 740,0 2/0
15114 RD 6 768 x 0,1 6,0 60,0 71,0 10 15134 BN 70 8967 x 0,1 15,5 672,0 740,0 2/0
15094 BK 10 1280 x 0,1 7,3 100,0 130,0 8 15132 RD 70 8967 x 0,1 15,5 672,0 740,0 2/0
15136 GN-YE 10 1280 x 0,1 7,3 100,0 130,0 8
15118 BU 10 1280 x 0,1 7,3 100,0 130,0 8
15119 BN 10 1280 x 0,1 7,3 100,0 130,0 8
15117 RD 10 1280 x 0,1 7,3 100,0 130,0 8
15095 BK 16 2048 x 0,1 8,8 160,0 187,0 6
15137 GN-YE 16 2048 x 0,1 8,8 160,0 187,0 6
15121 BU 16 2048 x 0,1 8,8 160,0 187,0 6
15122 BN 16 2048 x 0,1 8,8 160,0 187,0 6
15120 RD 16 2048 x 0,1 8,8 160,0 187,0 6
15096 BK 25 3234 x 0,1 10,5 240,0 294,0 4
15138 GN-YE 25 3234 x 0,1 10,5 240,0 294,0 4
15124 BU 25 3234 x 0,1 10,5 240,0 294,0 4
15125 BN 25 3234 x 0,1 10,5 240,0 294,0 4
15123 RD 25 3234 x 0,1 10,5 240,0 294,0 4
298
Single Conductors
Application
PUR-single cores are suited for installation in switch cabinets, cable assemblies and electronic equipment. Inductive loops in the road surface for
controlling of light signalling equipment.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
K
sec. approx. mm weight 9005 - 5015 8003 3000 1013 7000 4005 1021 3015 - 5010 2003 1001 -
mm kg / km
approx. RAL
Part no. 50651 50650 50652 50653 50654 50655 50656 50657 50658 50661 50660 50662 50659 50663 50664
0,5 2,2 4,8 - - - - - - - - - - - - - - -
Part no. 50666 50665 50667 50668 50669 50670 50671 50672 50673 50676 50675 50677 50674 50678 50679
0,75 2,4 7,2 - - - - - - - - - - - - - - -
Part no. 50681 50680 50682 50683 50684 50685 50686 50687 50688 50691 50690 50692 50689 50693 50694
1 2,5 9,6 - - - - - - - - - - - - - - -
Part no. 50696 50695 50697 50698 50699 50700 50701 50702 50703 50706 50705 50707 50704 50708 50709
1,5 3,0 14,4 - - - - - - - - - - - - - - -
Part no. 50711 50710 50712 50713 50714 50715 50716 50717 50718 50721 50720 50722 50719 50723 50724
2,5 3,7 24,0 - - - - - - - - - - - - - - -
Part no. 50726 50725 50727 50728 50729 50730 50731 50732 50733 50736 50735 50737 50734 50738 50739
4 4,3 38,0 - - - - - - - - - - - - - - -
Part no. 50741 50740 50742 50743 50744 50745 50746 50747 50748 50751 50750 50752 50749 50753 50754
6 5,1 58,0 - - - - - - - - - - - - - - -
Part no. 50756 50755 50757 50758 50759 50760 50761 50762 50763 50766 50765 50767 50764 50768 50769
10 6,8 96,0 - - - - - - - - - - - - - - -
Part no. 50771 50770 50772 50773 50774 50775 50776 50777 50778 50781 50780 50782 50779 50783 50784
16 7,8 154,0 - - - - - - - - - - - - - - -
Part no. 50786 50785 50787 50788 50789 50790 50791 50792 50793 50796 50795 50797 50794 50798 50799
25 10,0 240,0 - - - - - - - - - - - - - - -
Part no. 50801 50800 50802 50803 50804 50805 50806 50807 50808 50811 50810 50812 50809 50813 50814
35 11,4 336,0 - - - - - - - - - - - - - - -
Part no. 50816 50815 50817 50818 50819 50820 50821 50822 50823 50826 50825 50827 50824 50828 50829
50 13,2 480,0 - - - - - - - - - - - - - - -
Part no. 50831 50830 50832 50833 50834 50835 50836 50837 50838 50841 50840 50842 50839 50843 50844
70 15,4 672,0 - - - - - - - - - - - - - - -
Part no. 50846 50845 50847 50848 50849 50850 50851 50852 50853 50856 50855 50857 50854 50858 50859
95 17,7 912,0 - - - - - - - - - - - - - - -
Part no. 50861 50860 50862 50863 50864 50865 50866 50867 50868 50871 50870 50872 50869 50873 50874
120 19,2 1152,0 - - - - - - - - - - - - - - -
Part no. 50876 50875 50877 50878 50879 50880 50881 50882 50883 50886 50885 50887 50884 50888 50889
150 22,0 1440,0 - - - - - - - - - - - - - - -
299
Single Conductors
Application
Halogen-free single-core wires are used for installation in dry environments for wiring up lighting fixtures and units where valuable assets are to
protected from further damage resulting from fire. These types are suitable for laying in tubes on and under plaster, as well as in closed installation
ducts.
H07Z-K, suitable for protected, permanent laying in or on lighting installations or switching and control equipment up to 1000 V AC or 750 V DC to
earth.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05Z-K
Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE D-BU OG U-BU
sec. min. - max. weight approx.
mm mm kg / km kg / km
Part no. 52872 52873 52874 52875 52876 52877 52878 52879 52880 52945 52946 53071
0,5 2,1 - 2,6 4,8 9,0 - - - - - - - - - - - -
Part no. 52881 52882 52883 52884 52885 52886 52887 52888 52889 52947 52948 53072
0,75 2,2 - 2,8 7,2 12,4 - - - - - - - - - - - -
Part no. 52890 52891 52892 52893 52894 52895 52896 52897 52898 52949 52950 53073
1 2,4 - 2,9 9,6 15,0 - - - - - - - - - - - -
H07Z-K
Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT YE D-BU OG U-BU
sec. min. - max. weight approx.
mm mm kg / km kg / km
Part no. 51768 51769 51770 51771 51772 51773 51774 51775 51776 52951 52952 53074
1,5 2,8 - 3,5 14,4 24,0 - - - - - - - - - - - -
Part no. 51777 51778 51779 51780 51781 51782 51783 51784 51785 52953 52954 53075
2,5 3,4 - 4,3 24,0 35,0 - - - - - - - - - - - -
Part no. 51786 51787 51788 51789 51790 51791 51792 51793 51794 52955 52956 53076
4 3,9 - 4,9 38,0 51,0 - - - - - - - - - - - -
Part no. 51795 51796 51797 51798 51799 51800 51801 51802 51803 52957 52958 53077
6 4,4 - 5,5 58,0 71,0 - - - - - - - - - - - -
Part no. 51804 51805 51806 51807 51808 51809 51810 51811 51812 52959 52960 53078
10 5,7 - 7,1 96,0 118,0 - - - - - - - - - - - -
Part no. 51813 51814 51815 51816 51817 51818 51819 51820 51821 52961 52962 53079
16 6,7 - 8,4 154,0 180,0 - - - - - - - - - - - -
Part no. 51822 51823 51824 51825 51826 51827 51828 51829 51830 52963 52964 53080
25 8,4 - 10,6 240,0 278,0 - - - - - - - - - - - -
Part no. 51831 51832 51833 51834 51835 51836 51837 51838 51839 52965 52966 53081
35 9,7 - 12,1 336,0 375,0 - - - - - - - - - - - -
Part no. 51840 51841 51842 51843 51844 51845 51846 51847 51848 52967 52968 53082
50 11,5 - 14,4 480,0 560,0 - - - - - - - - - - - -
Continuation
300
Single Conductors
2,1 - 2,6
kg / km
4,8
kg / km
9,0
52809
-
52810
-
52811
-
52812
-
52813
-
52814
-
52815
-
52816
-
-
-
52817
-
52819
-
-
-
K
Part no. 52821 52822 52823 52824 52825 52826 52827 52828 - 52829 52831 -
0,75 2,2 - 2,8 7,2 12,4 - - - - - - - - - - - -
Part no. 52833 52834 52835 52836 52837 52838 52839 52840 - 52841 52843 -
1 2,4 - 2,9 9,6 15,0 - - - - - - - - - - - -
301
Single Conductors
H05G-U / -K / H07G-U / -R / -K
Application
For inside wiring of switch boards and distributors as well as of operating parts such as in or on lights, for the connection of electric heaters with a
nominal voltage up to 1000 V alternating voltage or up to 750 V direct voltage against ground. These single cores are all allowed for laying in tubes,
on and under plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05G-U (single wire) H07G-U (single wire)
Part no. Cross- Outer Cop. Weight AWG-No. Part no. Cross- Outer Cop. Weight AWG-No.
section min. - max. weight approx. section min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
541xx 0,5 1,9 - 2,4 4,8 10,0 20 544xx 1,5 2,8 - 3,5 14,4 24,0 16
542xx 0,75 2,1 - 2,6 7,2 15,0 18 545xx 2,5 3,4 - 4,3 24,0 35,0 14
543xx 1 2,2 - 2,8 9,6 16,0 17 546xx 4 4,0 - 5,0 38,0 53,0 12
302
Single Conductors
Application
Therm insulated wires are ideal for use in power current installation, switch cabinets, motors and transformers which are subject to direct contact with
high temperatures (e. g. varnishing machines and drying towers etc.). These are also suitable for inside wiring of electrical equipments such as lighting
and heating apparatus.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
LiYW 105C
Cross- Outer Cop. Weight BK GN-YE BU BN RD WH GY VT D-BU
section mm weight approx.
mm kg / km kg / km
Part no. 29500 29501 29502 29503 29504 29505 29506 29507 29508
0,14 1,3 1,4 3,2 - - - - - - - - -
Part no. 29509 29510 29511 29512 29513 29514 29515 29516 29517
0,25 1,8 2,4 4,3 - - - - - - - - -
Part no. 29518 29519 29520 29521 29522 29523 29524 29525 29526
0,5 2,6 4,8 7,2 - - - - - - - - -
H05V2-K 90C
Cross- Outer Cop. Weight AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No. AWG-No.
section min. - max. weight approx. BK GN-YE BU BN RD WH GY VT D-BU
mm mm kg / km kg / km
Part no. 29942 29943 29944 29945 29946 29947 29948 29949 29950
0,5 2,1 - 2,5 4,8 8,7 20 20 20 20 20 20 20 20 20
Part no. 29951 29952 29953 29954 29955 29956 29957 29958 29959
0,75 2,2 - 2,7 7,2 11,9 18 18 18 18 18 18 18 18 18
Part no. 29960 29961 29962 29963 29964 29965 29966 29967 29968
1 2,4 - 2,8 9,6 14,0 17 17 17 17 17 17 17 17 17
303
Single Conductors
Application
Therm insulated wires are ideal for use in power current installation, switch cabinets, motors and transformers which are subject to direct contact with
high temperatures (e. g. varnishing machines and drying towers etc.). These are also suitable for inside wiring of electrical equipments such as lighting
and heating apparatus. Suitable for fixed protected installation in, or on lighting or controlgear for voltages up to 1000 V a.c. or, up to 750 V d.c. to
earth.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
304
Single Conductors
Application
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systems
and distributors in equipment and plant and machinery, suitable for laying in tubes on and under plaster, in closed installation ducts, as well as for
traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks. For a protected installation, these
cables may be used at a nominal voltage of up to 1000 V alternating current or a direct current up to 750 V when earthed. The maximum operating
d. c. voltage used in rail vehicles shall not exceed 900 V when earthed. These halogen-free single core cables are characterised by their amazingly
high long-time resistance to temperature and feature among the leading halogen-free, flame resistant products in the world. These single core cables
significantly contribute to safety and the environment.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
305
Single Conductors
306
Single Conductors
Application
Special single cores for use in high, resp. low temperature areas. They are used mainly in the steel producing industries, in aviation industries as well
as in ship building, cement, glas and ceramic factories. As this single cores are halogen-free, especially suited for use in power stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
SiF SiFF
Part no. Cross- Outer Cop. Weight AWG-No. Part no. Cross- Outer Cop. Weight AWG-No.
section approx. mm weight approx. section approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
232xx 0,25 1,9 2,4 5,5 24 451xx 0,25 1,9 2,4 6,0 24
233xx 0,5 2,1 4,8 8,6 20 452xx 0,5 2,2 4,8 10,0 20
234xx 0,75 2,4 7,2 11,8 18 453xx 0,75 2,5 7,2 13,0 18
235xx 1 2,5 9,6 13,5 17 454xx 1 2,6 9,6 15,0 17
236xx 1,5 2,8 14,4 18,5 16 455xx 1,5 3,1 14,4 19,0 16
237xx 2,5 3,4 24,0 30,0 14 456xx 2,5 3,7 24,0 32,0 14
238xx 4 4,2 38,0 47,3 12 457xx 4 4,4 38,0 50,0 12
239xx 6 5,0 58,0 71,1 10 458xx 6 5,2 58,0 73,0 10
246xx 10 6,6 96,0 119,4 8 459xx 10 6,8 96,0 125,0 8
247xx 16 7,4 154,0 187,7 6
248xx 25 9,2 240,0 289,6 4
307
Single Conductors
Note
Please complete the part number for these
cables by adding the suffix for the colour
required as per the list:
00 = green, 01 = black, 02 = red,
03 = blue, 04 = brown, 05 = white,
06 = grey, 07 = violet, 08 = yellow,
09 = orange, 10 = transparent,
11 = pink, 12 = beige, 13 = 2-colour
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
Special single cores for use in high, resp. low temperature areas. They are used mainly in the steel producing industries, in aviation industries as well
as in ship building, cement, glas and ceramic factories. As this single cores are halogen-free, especially suited for use in power stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
SiF/GL SiD
Part no. Cross- Outer Cop. Weight AWG-No. Part no. Cross- Outer Cop. Weight AWG-No.
section approx. mm weight approx. section approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
47001 0,25 2,4 2,4 7,7 24 461xx 0,2 1,7 1,9 4,2 -
47002 0,5 2,5 4,8 12,4 20 462xx 0,28 1,8 2,7 5,1 -
47003 0,75 2,8 7,2 16,2 18 463xx 0,5 2,0 4,8 7,5 20
47004 1 2,9 9,6 18,2 17 464xx 0,75 2,1 7,2 10,2 18
47005 1,5 3,2 14,4 23,4 16 465xx 1 2,3 9,6 12,6 17
47006 2,5 3,8 24,0 35,2 14 466xx 1,5 2,5 14,4 18,1 16
47007 4 4,6 38,0 53,5 12 467xx 2,5 3,2 24,0 28,7 14
47008 6 5,4 58,0 77,4 10 468xx 4 3,9 38,0 45,2 12
47009 10 7,6 96,0 129,2 8 469xx 6 4,4 58,0 64,3 10
47010 16 8,4 154,0 198,4 6
47011 25 10,2 240,0 303,0 4 SiD/GL
47012 35 11,3 336,0 413,2 2 Part no. Cross- Outer Cop. Weight AWG-No.
47013 50 13,4 480,0 577,8 1 section approx. mm weight approx.
mm kg / km kg / km
47014 0,5 2,4 4,8 10,0 20
47015 0,75 2,6 7,2 15,0 18
47016 1 2,7 9,6 19,0 17
47017 1,5 3,0 14,4 28,0 16
47018 2,5 3,6 24,0 40,0 14
47019 4 4,3 36,0 55,0 12
47020 6 5,0 58,0 80,0 10
308
Single Conductors
Application
FZ-LSi, blue
This ignition cable is suitable for use at high and extremely alternating ambient temperatures up to +180C. Applications include engine manufacturing,
valve manufacturing and heating technology. As protection against mechanical damages a glass fibre braiding and a silicone sheath covers the core
insulation.
FZ-LS, red
This ignition cable is suitable for use at high and extremely alternating ambient temperatures up to +180C. Applications include the lamp and lighting
industry and cooling and airconditioning technology.
Neon-light-cable, yellow
This cable is primarily suitable for use at high and extremely alternating ambient temperatures such as in the lamp and lighting industry. Protected
installation is required.
FZ-LSi ignition cable FZ-LS high-voltage ignition cable 15 and 20kV
Part no. Core Cross- Cond. Outer Cop. Weight AWG-No. Part no. Core Cross- Cond. Outer Cop. Weight AWG-No.
colour sec. make-up approx. weight approx. colour sec. make-up approx. weight approx.
mm (nom. val.) mm kg / km kg / km mm (nom. val.) mm kg / km kg / km
n x wire n x wire
23110 BU 0,5 7 x 0,3 5,0 4,8 36,0 20 23109 red-brown 1 19 x 0,25 5,0 9,6 34,0 17
23106 BU 1 19 x 0,25 7,5 9,5 65,0 17 23108 red-brown 1 19 x 0,25 7,0 9,6 60,0 17
23107 BU 1,5 28 x 0,26 8,5 14,4 88,0 16
neon light cables (neon cable) 3,5kV, 4,0kV and 7,5kV
Part no. Core Cross- Cond. Outer Cop. Weight AWG-No.
colour sec. make-up approx. weight approx.
mm (nom. val.) mm kg / km kg / km
n x wire
23147 YE 1,5 30 x 0,25 4,4 14,4 32,0 16
23148 YE 1,5 30 x 0,25 6,6 14,4 59,0 16
23149 YE 1,5 30 x 0,25 7,6 14,4 75,0 16
309
Single Conductors
Note
Please complete the above part-no. for the
colour required using the following table:
1 = black, 2 = red, 3 = blue,
4 = brown, 5 = white, 6 = transparent,
7 = 2-colour, 8 = other colours
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
HELUFLON single cores are predominantly used for installing in control cabinets subjected to high thermal effects as well as in brickworks, heaters,
kitchen fitments and measuring appliances as well as in the chemical industry. These single cores are non-flammable and resistant to acids, alkalis,
solvents, oil and petrol.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Copper wire, tinned Copper wire, bare
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
2551x 1 x 0,14 1,0 1,4 2,6 26 2496x 1 x 2,5 2,6 24,0 26,4 14
2552x 1 x 0,25 1,1 2,4 4,1 24 2497x 1x4 3,2 38,0 43,1 12
2553x 1 x 0,5 1,4 4,8 8,0 20 2498x 1x6 3,9 58,0 65,9 10
2554x 1 x 0,75 1,5 7,2 9,7 18 2499x 1 x 10 5,1 96,0 115,0 8
2555x 1x1 1,8 9,6 12,7 17 2037x 1 x 16 6,7 154,0 175,0 6
2556x 1 x 1,5 2,2 14,4 17,9 16
2557x 1 x 2,5 2,6 24,0 26,4 14 copper wires, silvered
2558x 1x4 3,2 38,0 43,1 12 Part no. No.cores x Outer Cop. AG Weight AWG-No.
2559x 1x6 3,9 58,0 65,9 10 cross-sec. approx. mm weight weight approx.
2560x 1 x 10 5,1 96,0 115,0 8 mm kg / km kg / km kg / km
2561x 1 x 16 6,7 154,0 175,0 6 2026x 1 x 0,14 1,0 1,35 0,09 2,6 26
2027x 1 x 0,25 1,1 2,4 0,13 4,1 24
Copper wire, bare 2028x 1 x 0,5 1,4 4,8 0,17 8,0 20
Part no. No.cores x Outer Cop. Weight AWG-No. 2029x 1 x 0,75 1,5 7,2 0,20 9,7 18
cross-sec. approx. mm weight approx. 2030x 1x1 1,8 9,6 0,26 12,7 17
mm kg / km kg / km 2031x 1 x 1,5 2,2 14,4 0,35 17,9 16
2490x 1 x 0,14 1,0 1,35 2,6 26 2032x 1 x 2,5 2,6 24,0 0,70 26,4 14
2491x 1 x 0,25 1,1 2,4 4,1 24 2033x 1x4 3,2 38,0 1,20 43,1 12
2492x 1 x 0,5 1,4 4,8 8,0 20 2034x 1x6 3,9 58,0 1,70 65,9 10
2493x 1 x 0,75 1,5 7,2 9,7 18 2035x 1 x 10 5,1 96,0 2,80 115,0 8
2494x 1x1 1,8 9,6 12,7 17 2036x 1 x 16 6,7 154,0 4,80 175,0 6
2495x 1 x 1,5 2,2 14,4 17,9 16
310
Single Conductors
K
Conductor temperature range DIN VDE 0472 part 804 test method B)
bare copper +130C
tinned copper +180C Note
silver pl. copper +200C Please complete the above part-no. for the
nickel pl. copper +260C colour required using the following table:
1 = black, 2 = red, 3 = blue,
4 = brown, 5 = white, 6 = transparent,
7 = 2-colour, 8 = other colour
Conductor bare, tinned or nickel plated on
request
Application
HELUFLON single cores are predominantly used for installing in control cabinets subjected to high thermal effects as well as in brickworks, heaters,
kitchen fitments and measuring appliances as well as in the chemical industry. These single cores are non-flammable and resistant to acids, alkalis,
solvents, oil and petrol.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
600 V 1000 V
Part no. AWG-No. No. Cross- Outer Cop. AG Weight Part no. AWG-No. No. Cross- Outer Cop. AG Weight
cond. section approx. weight weight approx. cond. section approx. weight weight approx.
mm mm kg / km kg / km kg / km mm mm kg / km kg / km kg / km
2511x 32 7 0,03 0,70 0,4 0,03 0,4 2531x 32 7 0,03 1,00 0,4 0,03 0,42
2512x 30 7 0,06 0,81 0,6 0,04 0,59 2532x 30 7 0,06 1,07 0,6 0,04 0,65
2513x 28 7 0,09 0,89 0,9 0,06 0,93 2533x 28 7 0,09 1,14 0,9 0,06 1,0
2514x 26 7 0,14 0,99 1,4 0,07 1,47 2534x 26 7 0,14 1,24 1,4 0,07 1,56
2515x 26 19 0,14 0,99 1,4 0,09 1,58 2535x 26 19 0,14 1,24 1,4 0,09 1,68
2516x 24 7 0,21 1,12 2,3 0,07 2,31 2536x 24 7 0,21 1,37 2,3 0,07 2,4
2517x 24 19 0,24 1,12 2,3 0,13 2,52 2537x 24 19 0,24 1,37 2,3 0,13 2,65
2518x 22 7 0,35 1,27 3,5 0,10 3,68 2538x 22 7 0,35 1,52 3,5 0,10 3,85
2519x 22 19 0,38 1,27 3,5 0,17 3,99 2539x 22 19 0,38 1,50 3,5 0,17 4,2
2520x 20 7 0,57 1,47 5,6 0,12 6,0 2540x 20 7 0,57 1,72 5,6 0,12 6,3
2521x 20 19 0,57 1,47 6,1 0,18 6,4 2541x 20 19 0,57 1,72 6,1 0,18 6,9
2522x 18 7 0,90 1,74 9,6 0,22 9,45 2542x 18 7 0,90 2,00 9,6 0,22 10,65
2523x 18 19 0,95 1,74 9,6 0,27 10,2 2543x 18 19 0,95 2,00 9,6 0,27 13,65
2524x 16 19 1,23 2,04 13,5 0,29 12,9 2544x 16 19 1,23 2,26 13,5 0,29 21,38
2525x 14 19 1,94 2,40 18,0 0,38 20,3 2545x 14 19 1,94 2,76 18,0 0,38 33,95
311
Single Conductors
Application
The wide temperature range offered by this cable type makes it especially suited for use in the aviation and aerospace industries, for atomic power
stations and in the steel making and chemical industries. For the critical applications, for example mechanical stress, we advise for consultation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
312
Single Conductors
Application
HELUTHERM 600
Cables are used in applications where extremely high connecting and ambient temperatures occur, e. g. in iron and steel works, rolling mills, foundries,
glass and ceramic plants, in power construction as well as for wiring resistances in electrical heating equipment, furnaces and in thermoplastic forming.
Good characteristics in the presence of moisture and chemical effects.
HELUTHERM 600-ES
The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The high-grade braiding also gives
this cable an attractive appearance. The braided screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC. K
HELUTHERM 600
Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +400C (A)
51703 1 x 0,25 4 x 0,3 2,0 346 1,5 2,4 9,5 24
51704 1 x 0,5 7 x 0,3 2,3 175 2,5 4,8 11,5 20
51705 1 x 0,75 11 x 0,3 2,6 115 4,5 7,2 15,0 18
51706 1x1 14 x 0,3 2,8 88 5,5 9,6 17,8 17
51707 1 x 1,5 21 x 0,3 3,2 59 7 14,4 24,0 16
51708 1 x 2,5 35 x 0,3 3,7 35 10 24,0 36,0 14
51709 1x4 56 x 0,3 4,5 22 13,5 38,0 54,5 12
51710 1x6 84 x 0,3 6,0 14,6 16 58,0 77,0 10
51711 1 x 10 140 x 0,3 8,0 8,8 21 96,0 150,0 8
51712 1 x 16 228 x 0,3 9,1 5,5 28 154,0 225,0 6
51713 1 x 25 354 x 0,3 10,8 3,5 36 240,0 340,0 4
51714 1 x 35 495 x 0,3 13,0 2,5 58 336,0 440,0 2
51715 1 x 50 707 x 0,3 13,5 1,5 70 480,0 600,0 1
HELUTHERM 600-ES
Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +400C (A)
50475 1 x 0,5 7 x 0,3 3,2 175 2,5 4,8 21,0 20
50476 1 x 0,75 11 x 0,3 3,5 115 4,5 7,2 29,0 18
50477 1x1 14 x 0,3 3,7 88 5,5 9,6 38,0 17
50478 1 x 1,5 21 x 0,3 4,1 59 7 14,4 44,0 16
50479 1 x 2,5 35 x 0,3 4,6 35 10 24,0 56,0 14
50480 1x4 56 x 0,3 5,4 22 13,5 38,0 78,0 12
50481 1x6 84 x 0,3 6,9 14,6 16 58,0 112,0 10
50482 1 x 10 140 x 0,3 8,9 8,8 21 96,0 198,0 8
50483 1 x 16 228 x 0,3 10,0 5,5 28 154,0 281,0 6
50484 1 x 25 354 x 0,3 11,7 3,5 36 240,0 410,0 4
50485 1 x 35 495 x 0,3 15,1 2,5 58 336,0 536,0 2
50486 1 x 50 707 x 0,3 15,6 1,5 70 480,0 697,0 1
313
Single Conductors
Application
HELUTHERM 800
Cables are used in applications where extremely high connecting and ambient temperatures occur, e. g. in iron and steel works, rolling mills, foundries,
glass and ceramic plants, in power construction as well as for wiring resistances in electrical heating equipment, furnaces and in thermoplastic forming.
Good characteristics in the presence of moisture and chemical effects.
HELUTHERM 800-ES
The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The high-grade braiding also gives
this cable an attractive appearance. The braided screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
HELUTHERM 800
Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +700C (A)
51716 1 x 0,25 4 x 0,3 2,2 346 1 2,4 10,2 24
51717 1 x 0,5 7 x 0,3 2,3 175 2 4,8 12,0 20
51718 1 x 0,75 11 x 0,3 2,9 115 3 7,2 16,0 18
51719 1x1 14 x 0,3 3,2 88 4 9,6 19,0 17
51720 1 x 1,5 21 x 0,3 3,2 59 5 14,4 26,5 16
51721 1 x 2,5 35 x 0,3 3,7 35 7 24,0 38,8 14
51722 1x4 56 x 0,3 4,5 22 9 38,0 57,0 12
51723 1x6 84 x 0,3 5,9 14,6 12 58,0 81,0 10
51724 1 x 10 140 x 0,3 8,0 8,8 14 96,0 156,0 8
51725 1 x 16 228 x 0,3 9,0 5,5 20 154,0 240,0 6
51726 1 x 25 354 x 0,3 10,6 3,5 24 240,0 370,0 4
51727 1 x 35 495 x 0,3 13,4 2,5 40 336,0 490,0 2
51728 1 x 50 707 x 0,3 14,0 1,5 48 480,0 645,0 1
HELUTHERM 800-ES
Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +700C (A)
50488 1 x 0,5 7 x 0,3 3,5 175 2 4,8 23,0 20
50489 1 x 0,75 11 x 0,3 3,8 115 3 7,2 31,0 18
50490 1x1 14 x 0,3 4,1 88 4 9,6 40,0 17
50491 1 x 1,5 21 x 0,3 4,5 59 5 14,4 47,0 16
50492 1 x 2,5 35 x 0,3 4,9 35 7 24,0 59,0 14
50493 1x4 56 x 0,3 5,8 22 9 38,0 82,0 12
50494 1x6 84 x 0,3 7,3 14,6 12 58,0 118,0 10
50495 1 x 10 140 x 0,3 9,4 8,8 14 96,0 209,0 8
50496 1 x 16 228 x 0,3 10,5 5,5 20 154,0 298,0 6
50497 1 x 25 354 x 0,3 12,2 3,5 24 240,0 452,0 4
50498 1 x 35 495 x 0,3 15,5 2,5 40 336,0 592,0 2
50499 1 x 50 707 x 0,3 16,1 1,5 48 480,0 650,0 1
314
Single Conductors
Application
HELUTHERM 1200
Cables are used in applications, where extremely high connecting and ambient temperatures occur, e. g. in iron and steel works, rolling mills, foundries,
glass and ceramic plants, in furnace and power plant construction as well for wiring resistances in electrical heating equipment, furnaces and in
thermoplastic forming. Good characteristics in the presence of moisture and chemical effects.
HELUTHERM 1200-ES
The robust braiding of high-grade steel protects the cable from aggressive atmospheres and mechanical stresses. The high-grade braiding also gives
this cable an attractive appearance. The braided screen can also be used for earthing purposes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC. K
HELUTHERM 1200
Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +700C (A)
51729 1 x 0,5 7 x 0,3 2,3 175 2 4,8 12,3 20
51730 1 x 0,75 11 x 0,3 2,6 115 3 7,2 16,1 18
51731 1x1 14 x 0,3 2,8 88 4 9,6 19,8 17
51732 1 x 1,5 21 x 0,3 3,2 59 5 14,4 27,5 16
51733 1 x 2,5 35 x 0,3 3,7 35 7 24,0 39,8 14
51734 1x4 56 x 0,3 4,5 22 9 38,0 58,0 12
51735 1x6 84 x 0,3 5,9 14,6 12 58,0 83,0 10
51736 1 x 10 140 x 0,3 8,0 8,8 14 96,0 160,0 8
51737 1 x 16 228 x 0,3 9,0 5,5 20 154,0 244,0 6
51738 1 x 25 354 x 0,3 10,6 3,5 24 240,0 376,0 4
51739 1 x 35 495 x 0,3 13,6 2,5 40 336,0 495,0 2
51740 1 x 50 707 x 0,3 14,5 1,5 48 480,0 654,0 1
HELUTHERM 1200-ES
Part no. No.cores x Conductor Outer Conductor Max. permiss. Nickel Weight AWG-No.
cross-sec. construction approx. mm resistance current carrying weight approx. kg / km
mm at 20C capacity kg / km
Ohm / km at +700C (A)
50635 1 x 0,5 7 x 0,3 3,6 175 2 4,8 26,0 20
50636 1 x 0,75 11 x 0,3 3,8 115 3 7,2 34,0 18
50637 1x1 14 x 0,3 4,2 88 4 9,6 42,0 17
50638 1 x 1,5 21 x 0,3 4,7 59 5 14,4 53,0 16
50639 1 x 2,5 35 x 0,3 5,0 35 7 24,0 64,0 14
50640 1x4 56 x 0,3 6,0 22 9 38,0 87,0 12
50641 1x6 84 x 0,3 7,5 14,6 12 58,0 120,0 10
50642 1 x 10 140 x 0,3 9,7 8,8 14 96,0 218,0 8
50643 1 x 16 228 x 0,3 10,9 5,5 20 154,0 314,0 6
50644 1 x 25 354 x 0,3 12,9 3,5 24 240,0 453,0 4
50645 1 x 35 495 x 0,3 15,7 2,5 40 336,0 593,0 2
50646 1 x 50 707 x 0,3 16,7 1,5 48 480,0 760,0 1
315
Single Conductors
Application
ESUY (H00V-D)
These high flexible earth conductors are used for earthing of portable equipment and short-circuiting. These cables specially perform a protective
function in repair live working of high voltage power supply company as EVU, in railway systems, failing current equipment, alternating current systems
and in networks of transmission and distribution. Because of that these are designated as safety cables.
ESY
These earthing cables offer special characteristics with low weights, high flexibility to a wide temperature range and the behavior in high temperature.
The protective sheath over conductor assures the essential function for protection against the mechanical and chemical stresses.
ESUY (H00V-D), high flexible
Part no. Cross- Cond. make-up Outer Cop. Weight AWG-No.
section n x wire approx. mm weight approx. kg / km
mm kg / km
28930 16 4200 x 0,07 8,3 194,0 230,0 6
28931 25 3192 x 0,1 9,5 280,0 335,0 4
28932 35 4480 x 0,1 11,2 415,0 475,0 2
28933 50 6383 x 0,1 13,2 585,0 670,0 1
28934 70 8918 x 0,1 15,6 820,0 905,0 2/0
28935 95 12100 x 0,1 17,4 1090,0 1220,0 3/0
28936 120 15300 x 0,1 19,8 1360,0 1505,0 4/0
28937 150 19152 x 0,1 23,4 1650,0 1940,0 300 kcmil
28938 185 23580 x 0,1 26,6 2150,0 2390,0 350 kcmil
28939 240 30600 x 0,1 30,2 2750,0 3090,0 500 kcmil
ESY, flexible
Part no. Cross- Cond. make-up Outer Cop. Weight AWG-No.
section n x wire approx. mm weight approx. kg / km
mm kg / km
28940 16 525 x 0,2 8,4 155,0 185,0 6
28941 25 798 x 0,2 9,8 240,0 270,0 4
28942 35 1120 x 0,2 11,4 336,0 390,0 2
28943 50 1617 x 0,2 13,8 480,0 575,0 1
28944 70 2254 x 0,2 16,4 672,0 810,0 2/0
28945 95 3087 x 0,2 18,2 912,0 1080,0 3/0
28946 120 3822 x 0,2 20,1 1152,0 1320,0 4/0
28947 150 4802 x 0,2 23,0 1440,0 1680,0 300 kcmil
316
Single Conductors
Application
This cable is employed as a highly-flexible high-current cathode cable for electroplating drum systems and as a wearing cable in the chemical industry.
Special feature: Despite the extremely thick wearing sheath, the highly flexible conductor enables good contact when installing the pear push. Good
flexibility is likewise ensured when the pear push comes into contact with the parts to be electroplated.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
K
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
700768 1 x 35 17,2 336,0 548,0 2 74749 1 x 120 27,0 1152,0 1520,0 4/0
75497 1 x 50 19,0 480,0 686,0 1 700769 1 x 150 28,0 1440,0 2002,0 300 kcmil
75498 1 x 70 21,5 672,0 950,0 2/0 700770 1 x 185 30,5 1776,0 2610,0 350 kcmil
75499 1 x 95 24,0 912,0 1386,0 3/0 700771 1 x 240 36,0 2304,0 3820,0 500 kcmil
317
Single Conductors
Application
For use between the welding generator and the hand-electrode and the workpiece. For use in the automobile industry, in shipbuilding, in transport
and conveyor systems, tool making machinery, welding robots etc. These cables retain their high flexibility even under influence of ozone, light,
oxygen, protective gases, oil and petrol. The robust construction makes these cables resistant to both to cold and the heat as well as to flames. They
are suitable for use in open spaces and in dry and damp conditions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H01N2-D: Cables with standard flexibility
Part no. No.cores x No.wires x Sheat Outer Cop. Weight AWG-No.
cross-sec. single wire Nominal value min. - max. weight approx. kg / km
mm mm mm mm kg / km
31001 1 x 10 320 x 0,2 2,0 7,7 - 9,7 96,0 135,0 8
31002 1 x 16 512 x 0,2 2,0 8,8 - 11,0 154,0 205,0 6
31003 1 x 25 800 x 0,2 2,0 10,1 - 12,7 240,0 302,0 4
31004 1 x 35 1120 x 0,2 2,0 11,4 - 14,2 336,0 420,0 2
31005 1 x 50 1600 x 0,2 2,2 13,2 - 16,5 480,0 586,0 1
31006 1 x 70 2240 x 0,2 2,4 15,3 - 19,2 672,0 798,0 2/0
31007 1 x 95 3024 x 0,2 2,6 17,1 - 21,4 912,0 1015,0 3/0
31008 1 x 120 614 x 0,5 2,8 19,2 - 24,0 1152,0 1310,0 4/0
31030 1 x 150 765 x 0,5 3,0 21,2 - 26,4 1440,0 1620,0 300 kcmil
31031 1 x 185 944 x 0,5 3,2 23,1 - 28,9 1776,0 1916,0 350 kcmil
31009 1 x 240 1225 x 0,5 3,4 25,0 - 29,5 2304,0 2540,0 500 kcmil
318
Single Conductors
Note
Version in 6 kV available on request.
AWG sizes are approximate equivalent K
values. The actual cross-section is in mm.
Application
Particularly suitable for protection against short circuits in laying and for inherently earth-fault-proof routing in rail vehicles and omnibuses. Also
suitable for laying in dry environments.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
38501 1 x 1,5 7,0 14,4 62,0 16 38509 1 x 50 18,0 480,0 650,0 1
38502 1 x 2,5 7,5 24,0 76,0 14 38510 1 x 70 20,5 672,0 900,0 2/0
38503 1x4 9,0 38,0 95,0 12 38511 1 x 95 24,0 912,0 1200,0 3/0
38504 1x6 9,5 58,0 140,0 10 38513 1 x 120 26,0 1152,0 1450,0 4/0
38505 1 x 10 11,0 96,0 190,0 8 38514 1 x 150 28,0 1440,0 1800,0 300 kcmil
38506 1 x 16 13,0 154,0 270,0 6 38512 1 x 185 31,0 1776,0 2200,0 350 kcmil
38507 1 x 25 15,0 240,0 410,0 4 38515 1 x 240 34,5 2304,0 2650,0 500 kcmil
38508 1 x 35 16,5 336,0 490,0 2 38516 1 x 300 38,0 2880,0 3250,0 600 kcmil
319
Single Conductors
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
Particularly suitable for protection against short circuits in laying and for inherently earth-fault-proof routing in rail vehicles and omnibuses. Also
suitable for laying in dry environments. In switching units and distributors, they are considered to be short circuit and inherently earth proof to
1000 V. Note: Considered as being short-circuit safe and inherently earth-fault-proof are those operating materials and conducting assemblies where
because of suitable measures and/or means applied, neither a short circuit nor a short to ground is to be expected under operating conditions which
are in accordance with those specified for the intended application.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
38517 1 x 1,5 5,9 14,4 62,0 16 38525 1 x 50 14,5 480,0 650,0 1
38518 1 x 2,5 6,2 24,0 76,0 14 38526 1 x 70 16,3 672,0 900,0 4
38519 1x4 6,8 38,0 95,0 12 38527 1 x 95 19,2 912,0 1200,0 3/0
38520 1x6 7,4 58,0 140,0 10 38528 1 x 120 21,0 1152,0 1450,0 4/0
38521 1 x 10 8,7 96,0 190,0 8 38529 1 x 150 22,8 1440,0 1800,0 300 kcmil
38522 1 x 16 9,5 154,0 270,0 6 38530 1 x 185 24,8 1776,0 2200,0 350 kcmil
38523 1 x 25 11,9 240,0 410,0 4 38531 1 x 240 27,1 2304,0 2650,0 500 kcmil
38524 1 x 35 13,1 336,0 490,0 2 38532 1 x 300 30,3 2880,0 3250,0 600 kcmil
320
Single Conductors
TOPFLEX 300 high flexible PVC single core, 0,6/1kV for drag chain and free move
application
Application
Thanks to their outstanding alternating bending stress characteristics, these cables are ideally suited for use in drag chains, and also for use in handling
devices, robots, and nearly any area requiring flexible used and free motion. Due to its resistance to mineral oils these cables are well suited for use in K
mechanical engineering, tool making, and systems engineering, and in steel mills and rolling mills in particularly critical areas. Suitable for installation
in dry, damp and wet environments. With the black sheath, can also be used outdoors.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX 300 black TOPFLEX 300 green-yellow
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
79623 1 x 2,5 4,2 24,0 42,0 14 79627 1 G 2,5 4,2 24,0 42,0 14
79624 1x4 5,1 38,4 58,0 12 79628 1G4 5,1 38,4 58,0 12
79625 1x6 6,0 57,6 85,0 10 79629 1G6 6,0 57,6 85,0 10
79626 1 x 10 7,4 96,0 130,0 8 79630 1 G 10 7,4 96,0 130,0 8
75431 1 x 16 8,8 154,0 210,0 6 75438 1 G 16 8,8 154,0 210,0 6
75432 1 x 25 10,7 240,0 300,0 4 75439 1 G 25 10,7 240,0 300,0 4
75433 1 x 35 12,1 336,0 420,0 2 75440 1 G 35 12,1 336,0 420,0 2
70519 1 x 50 14,0 480,0 580,0 1 70536 1 G 50 14,0 480,0 580,0 1
75434 1 x 70 16,3 672,0 780,0 2/0 75441 1 G 70 16,3 672,0 780,0 2/0
73714 1 x 95 18,3 912,0 1010,0 3/0 75442 1 G 95 18,3 912,0 1010,0 3/0
75435 1 x 120 20,0 1152,0 1200,0 4/0 73885 1 G 120 20,0 1152,0 1200,0 4/0
75436 1 x 150 23,0 1440,0 1600,0 300 kcmil 75443 1 G 150 23,0 1440,0 1600,0 300 kcmil
72872 1 x 185 24,8 1776,0 2030,0 350 kcmil 75444 1 G 185 24,8 1776,0 2030,0 350 kcmil
75437 1 x 240 28,7 2304,0 2600,0 500 kcmil 75445 1 G 240 28,7 2304,0 2600,0 500 kcmil
321
Single Conductors
Application
The special single cores are used for permanent flexible applications in machineries, machine tools, composting appliances and sewage-treatment
plants, animal stalls and greenhouses and used for permanent flexible application for movable automated machinery parts and multi-shift operation
as well as in open air. These cables are installed for flexible use with free movements without tensile stress or forced movements and suitable for
application in drag chains. The selected tinned copper wire conductor and tinned copper wire braid permit the installation in aggressive environments
as well as hydrogen sulfide, ammonia and sulfur dioxide.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing
speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the
instructions. Further technical details see selection table for drag chain cables, see lead text.
KOMPOSPEED 600-C
These screened cables are particularly suitable for the interference-free trans mission in instrumentation and control engineering applications
(electromagnetic compatibillity).
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
KOMPOSPEED 600 KOMPOSPEED 600-C
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
60288 1x6 6,5 58,0 83,0 10 60216 1x6 7,3 71,0 101,0 10
60289 1 x 10 8,4 96,0 132,0 8 60217 1 x 10 9,1 122,0 168,0 8
60290 1 x 16 9,5 154,0 188,0 6 60218 1 x 16 10,1 180,0 217,0 6
60291 1 x 25 11,2 240,0 281,0 4 60219 1 x 25 12,2 282,0 342,0 4
60292 1 x 35 13,0 336,0 404,0 2 60220 1 x 35 14,2 386,0 468,0 2
60293 1 x 50 15,4 480,0 531,0 1 60221 1 x 50 17,0 535,0 584,0 1
60294 1 x 70 17,2 672,0 729,0 2/0 60222 1 x 70 19,2 750,0 822,0 2/0
60295 1 x 95 20,0 912,0 1049,0 3/0 60223 1 x 95 21,8 1004,0 1190,0 3/0
60296 1 x 120 21,0 1152,0 1220,0 4/0 60224 1 x 120 23,8 1260,0 1400,0 4/0
60297 1 x 150 23,8 1440,0 1510,0 300 kcmil 60225 1 x 150 26,0 1570,0 1710,0 300 kcmil
60298 1 x 185 26,2 1776,0 1932,0 350 kcmil 60226 1 x 185 28,8 1911,0 2021,0 350 kcmil
62500 1 x 240 34,0 2470,0 2850,0 500 kcmil
322
04 | 324
COMPENSATING CABLES
325
COLOR CODING AND TEMPERATURE RANGES FOR
T+ERMAL CABLES COMPENSATING CABLES
IFentication IFentication
+ -
plus Oinus T+L AGL T+L AGL
T Cu Cu Ni TX TC TX
-25C to +100C -25C to +100C 0C to +100C
U Cu Cu Ni
J Fe Cu Ni JX JC JX
-25C to +200C -25C to +250C 0C to +200C
Fe Cu Ni
L
E
Ni Cr Cu Ni EX EC EX
-25C to +200C -25C to +250C 0C to +200C
Ni Cr Ni
KX KC KX
-25C to +200C -25C to +200C 0C to +200C
K
Ni Cr Ni WC
0C to +100C
Ni Cr Ni VC VX
0C to +100C 0C to +100C
N Ni Cr Si Ni Si
R PtRh 13 Pt
S PtRh 10 Pt SC SX
0C to +200C 0C to +200C
B PtRh 30 PtRh 6 BC
0C to +100C
The hiIhest application teOpeTatuTe of the insulatinI OateTials As a Tule, intTinsicall[ safe caDles haXe a Dlue LacMet coloT anF an
oT the application teOpeTatuTe TanIe of the conFuctoT OateTial iFentication stTipe assiIneF to the eleOent
liOits the application teOpeTatuTe TanIe of the caDle The loweT
Xalue is XaliF
32
ANSI MC 91 DIN IEC 584 DIN 43710*
TX TX
0C to +100C -25C to +100C
UX**
0C to +200C
JX JX**
0C to +200C -25C to +200C
LX**
0C to +200C
L
EX EX
0C to +200C -25C to +200C
KX KX
0C to +200C -25C to +200C
KCA**
0C to +150C
KCB
0C to +100C
NX NC
-25C to +200C 0C to +150C
RCA/SCA
0C to +100C
SX RCB/SCB**
0C to +200C 0C to +200C
AccoTFinI to
BX DIN 4371085 BC
0C to +100C 0C to +100C
THL = Thermocouple wire EZaOple .CA CoOpensatinI caDle .CA plus positiXe coTe foT AGL .C
$*L = Compensating caDle .CA Oinus neIatiXe coTe foT AGL .C
* DIN 43710 was withFTawn in ApTil 1994 Thus the eleOent t[pes U anF L aTe no lonIeT stanFaTFi\eF ** stanFaTF t[pe
327
COMPENSATING CABLES
MateTials foT coOpensatinI caDles
328
COMPENSATING CABLES
Te
71 TFa nt
3 nce
tu
43 o e
Ta
us
N cc leO
pe
C e
O
pe
Fi
n nI
t[
Ta
DI in a le e
et
.
oZ
n
tio Ta
oZ
e
cM
C te
io
: e nI
pl
pT
ith al p
la e
O pT
at
La
ou
su u T
e on
w teTi cou
Dl Fi
ap
M ap
ul
in Tat
ca en
oc
nI ti
in
s
.
aT Met
a o
Ta alla
in
MI Iht
no
Z .D
of pe
O
oT
O O
eT
TO
Te
pe
eT
eT
in
O
st
Tt
ut
ei
c
Co
Th
In
Fo
Pa
Th
O
Ja
Te
T[
O
Single-pair: 2 x 1.5 mm2 (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48001 FE-CuNi .o L AE 1 L stTanFeF PVC - 5.4 TounF 7.5 40
48002 SoNiCT-SoNi . AN 1 L stTanFeF PVC - 5.4 TounF stationaT[ 7.5 40
-25C to +70C
48003 SoPtRh-SoPt S AP 1 L stTanFeF PVC - 5.4 TounF -10C to +80C 7.5 40
eZinI
48230 Cu-CuNi .o U AC 1 L stTanFeF PVC - 5.4 TounF -5C to +70C 7.5 40
48478 Fe-CuNi J AF 1 L stTanFeF PVC - 5.4 TounF 7.5 40
48004 Fe-CuNi .o L AE 1 M stTanFeF PVC - 5.4 TounF stationaT[ 10 40
48005 SoNiCT-SoNi . AN 1 M stTanFeF PVC - 5.4 TounF -25C to +70C 10 40
-10C to +80C
4800 SoPtRh-SoPt S AP 1 M stTanFeF PVC - 5.4 TounF eZinI 10 40
48231 Cu-CuNi .o U AC 1 M stTanFeF PVC - 5.4 TounF -5C to +70C 10 40
48007 Fe-CuNi .o L AE 1 L-SIL stTanFeF silicone - 5.4 TounF stationaT[ 7.5 40
48008 SoNiCT-SoNi . AN 1 L-SIL stTanFeF silicone - 5.4 TounF -25C to +180C 7.5 40
-0C to +180C eZinI
48009 SoPtRh-SoPt S AP 1 L-SIL stTanFeF silicone - 5.4 TounF -25C to +180C 7.5 40
48232 Cu-CuNi .o U AC 1 L-SIL stTanFeF silicone - 5.4 TounF shoTt tiOe +200C 7.5 40
48233 Fe-CuNi .o L AE 2 M-SIL stTanFeF silicone 7.8 TounF stationaT[ 15 248
TeZtile tape -25C to +180C
48234 SoNiCT-SoNi . AN 2 M-SIL stTanFeF silicone 7.8 TounF 15 248
leaF sheath -0C to +180C eZinI
48235 SoPtRh-SoPt S AP 2 M-SIL stTanFeF silicone 7.8 TounF -25C to +180C 15 248
tin. steel wiTe DTaiF
4823 Cu-CuNi .o U AC 2 M-SIL stTanFeF silicone 7.8 TounF shoTt tiOe +200C 15 248
48010 Fe-CuNi .o L AE 3 L paTallel Ilass-DeT 5.0Z7.2 oXal stationaT[ 7.5 4
48011 SoNiCT-SoNi . AN 3 L paTallel Ilass-DeT 5.0Z7.2 oXal -25C to +200C 7.5 4
Ilass-DeT DTaiF -0C to +200C
48012 SoPtRh-SoPt S AP 3 L paTallel Ilass-DeT 5.0Z7.2 oXal eZinI -25C to 7.5 4
48237 Cu-CuNi .o U AC 3 L paTallel Ilass-DeT 5.0Z7.2 oXal +200C 7.5 4
48238 Fe-CuNi .o L AE 3 Ln-SIL paTallel silicone 5.2Z7.4 oXal stationaT[ 7.5 2
48239 SoNiCT-SoNi . AN 3 Ln-SIL paTallel silicone 5.2Z7.4 oXal -25C to +180C 7.5 2
silicone -0C to +180C eZinI
48240 SoPtRh-SoPt S AP 3 Ln-SIL paTallel silicone 5.2Z7.4 oXal -25C to +180C 7.5 2
48241 Cu-CuNi .o U AC 3 Ln-SIL paTallel silicone 5.2Z7.4 oXal shoTt tiOe +200C 7.5 2
48013 Fe-CuNi .o L AE 4 L paTallel Ilass-DeT 5.8Z8.0 oXal stationaT[ 7.5 87
48014 SoNiCT-SoNi . AN 4 L paTallel Ilass-DeT Glass-DeT DTaiF 5.8Z8.0 oXal -25C to +200C 7.5 87
-0C to +200C
48015
48242
SoPtRh-SoPt
Cu-CuNi .o
S
U
AP 4 L paTallel
AC 4 L paTallel
Ilass-DeT
Ilass-DeT
IalX. steel wiTe DTaiF 5.8Z8.0
5.8Z8.0
oXal
oXal
eZinI
-25C to +200C
7.5
7.5
87
87 L
4801 Fe-CuNi .o L AE 4 Ln-SIL silicone .0Z8.2 oXal stationaT[ 7.5 85
48017 SoNiCT-SoNi . AN 4 Ln-SIL silicone silicone .0Z8.2 oXal -25C to +180C 7.5 85
-0C to +180C fleZinI
48018 SoPtRh-SoPt S AP 4 Ln-SIL silicone IalX. steel wiTe DTaiF .0Z8.2 oXal -25C to +180C 7.5 85
48243 Cu-CuNi .o U AC 4 Ln-SIL silicone .0Z8.2 oXal shoTt tiOe +200C 7.5 85
48244 Fe-CuNi .o L AE 5 L PVC PETP tape 8.1 TounF stationaT[ 7.5 93
48245 SoNiCT-SoNi . AN 5 L PVC IalX. Cu-TounF 8.1 TounF -25C to +70C 7.5 93
-10C to +80C
4824 SoPtRh-SoPt S AP 5 L PVC wiTe DTaiF 8.1 TounF fleZinI 7.5 93
48247 Cu-CuNi .o U AC 5 L PVC PVC LacMet 8.1 TounF -5C to +70C 7.5 93
48248 Fe-CuNi .o L AE L-SIL silicone 8.0 TounF stationaT[ 7.5 94
PETP tape -25C to +180C
48249 SoNiCT-SoNi . AN L-SIL silicone 8.0 TounF 7.5 94
Dl. Cu-ITounF wiTe fleZinI
48250 SoPtRh-SoPt S AP L-SIL silicone 8.0 TounF -0C to +180C 7.5 94
0.5 OO -25C to +180C
48251 Cu-CuNi .o U AC L-SIL silicone Alu tapesilicone 8.0 TounF shoTt tiOe 7.5 94
+200C
48252 Fe-CuNi .o L AE M-SIL silicone PETP tape 7.8 TounF stationaT[ 12 92
48253 SoNiCT-SoNi . AN M-SIL silicone Dl. Cu-ITounF wiTe 7.8 TounF -25C to +180C 12 92
-0C to +180C fleZinI
48254 SoPtRh-SoPt S AP M-SIL silicone 0.5 OO 7.8 TounF -25C to +180C 12 92
48255 Cu-CuNi .o U AC M-SIL silicone Alu tapesilicone 7.8 TounF shoTt tiOe +200C 12 92
48019 Fe-CuNi .o L AE 7 L paTallel PVC 5.5Z8.2 oXal stationaT[ 7.5 0
48020 SoNiCT-SoNi . AN 7 L paTallel PVC 5.5Z8.2 oXal -25C to +70C 7.5 0
Ilass-DeT -10C to +80C
48021 SoPtRh-SoPt S AP 7 L paTallel PVC 5.5Z8.2 oXal fleZinI 7.5 0
4825 Cu-CuNi .o U AC 7 L paTallel PVC 5.5Z8.2 oXal -5C to +70C 7.5 0
48022 Fe-CuNi .o L AE 8 L PVC .9Z9.0 oXal stationaT[ 7.5 82
48023 SoNiCT-SoNi . AN 8 L PVC Glass-fiDeT .9Z9.0 oXal -25C to +70C 7.5 82
-10C to +80C
48024 SoPtRh-SoPt S AP 8 L PVC IalX. steel wiTe DTaiF .9Z9.0 oXal fleZinI 7.5 82
48257 Cu-CuNi .o U AC 8 L PVC .9Z9.0 oXal -5C to +70C 7.5 82
48025 Fe-CuNi .o L AE 9 L PVC 7.0 TounF 7.5 79
4802 SoNiCT-SoNi . AN 9 L PVC 7.0 TounF stationaT[ 7.5 79
-25C to +70C
48027 SoPtRh-SoPt S AP 9 L PVC PVC 7.0 TounF -10C to +80 7.5 79
fleZinI
48258 Cu-CuNi .o U AC 9 L PVC 7.0 TounF -5C to +70C 7.5 79
48479 Fe-CuNi J AF 9 L PVC 7.0 TounF 7.5 79
48028 Fe-CuNi .o L AE 9-2 LS PVC 7.8 TounF 7.5 108
48029 SoNiCT-SoNi . AN 9-2 LS PVC 7.8 TounF stationaT[ 7.5 108
PVCIalX. -25C to +70C
48030 SoPtRh-SoPt S AP 9-2 LS PVC 7.8 TounF -10C to +80C 7.5 108
steel wiTe DTaiF fleZinI
48259 Cu-CuNi .o U AC 9-2 LS PVC 7.8 TounF -5C to +70C 7.5 108
48480 Fe-CuNi J AF 9-2 LS PVC 7.8 TounF 7.5 108
48031 Fe-CuNi .o L AE 9-2 LS< PVC 9.8 TounF stationaT[ 7.5 147
PVCIalX.
48032 SoNiCT-SoNi . AN 9-2 LS< PVC 9.8 TounF -25C to +70C 7.5 147
steel wiTe DTaiF -10C to +80C
4809 SoPtRh-SoPt S AP 9-2 LS< PVC 9.8 TounF fleZinI 7.5 147
PVC -5C to +70C
4820 Cu-CuNi .o U AC 9-2 LS< PVC 9.8 TounF 7.5 147
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF
329
COMPENSATING CABLES
Te
71 TFa nt
3 nce
tu
43 o e
Ta
us
N cc leO
pe
C e
O
pe
Fi
n nI
t[
Ta
DI in a le e
et
.
oZ
n
tio Ta
oZ
e
cM
C te
io
: e nI
pl
pT
ith al p
la e
O pT
at
La
ou
su uT
e on
w teTi cou
Dl Fi
ap
M ap
ul
in Tat
ca en
oc
nI ti
in
s
.
aT Met
a o
Ta alla
in
MI Iht
no
Z .D
of pe
O
oT
O O
eT
TO
Te
pe
eT
eT
in
O
st
Tt
ut
ei
c
Co
Th
In
Fo
Pa
Th
O
Ja
Te
T[
O
Single-pair: 2 x 1.5 mm2 (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48033 FE-CuNi .o L AE 9 M PVC 7.0 TounF stationaT[ 12 79
48034 SoNiCT-SoNi . AN 9 M PVC 7.0 TounF -25C to +70C 12 79
PVC -10C to +80
48035 SoPtRh-SoPt S AP 9 M PVC 7.0 TounF fleZinI 12 79
4821 Cu-CuNi .o U AC 9 M PVC 7.0 TounF -5C to +70C 12 79
4822 Fe-CuNi .o L AE 9-2 MS< PVC 9. TounF stationaT[ 12 144
PVCIalX.
4823 SoNiCT-SoNi . AN 9-2 MS< PVC 9. TounF -25C to +70C 12 144
steel wiTe DTaiF -10C to +80C
4824 SoPtRh-SoPt S AP 9-2 MS< PVC 9. TounF fleZinI 12 144
PVC -5C to +70C
4825 Cu-CuNi .o U AC 9-2 MS< PVC 9. TounF 12 144
4803 Fe-CuNi .o L AE 10 L-SIL paTallel silicone 5.5Z8.2 oXal stationaT[ 7.5 59
48037 SoNiCT-SoNi . AN 10 L-SIL paTallel silicone 5.5Z8.2 oXal -25C to +180C 7.5 59
Ilass-DeT -0C to +180C fleZinI
48038 SoPtRh-SoPt S AP 10 L-SIL paTallel silicone 5.5Z8.2 oXal -25C to +180C 7.5 59
482 Cu-CuNi .o U AC 10 L-SIL paTallel silicone 5.5Z8.2 oXal shoTt tiOe +200C 7.5 59
48039 Fe-CuNi .o L AE 11 L silicone .3Z9.0 oXal stationaT[ 7.5 82
48040 SoNiCT-SoNi . AN 11 L silicone Glass-fiDeT .3Z9.0 oXal -25C to +180C 7.5 82
-0C to +180C fleZinI
48041 SoPtRh-SoPt S AP 11 L silicone IalX. steel wiTe DTaiF .3Z9.0 oXal -25C to +180C 7.5 82
4827 Cu-CuNi .o U AC 11 L silicone .3Z9.0 oXal shoTt tiOe +200C 7.5 82
48042 Fe-CuNi .o L AE 11 LT silicone .7 TounF stationaT[ 7.5 83
48043 SoNiCT-SoNi . AN 11 LT silicone Glass-fiDeT .7 TounF -25C to +180C 7.5 83
-0C to +180C fleZinI
48044 SoPtRh-SoPt S AP 11 LT silicone IalX. steel wiTe DTaiF .7 TounF -25C to +180C 7.5 83
4828 Cu-CuNi .o U AC 11 LT silicone .7 TounF shoTt tiOe +200C 7.5 83
48045 Fe-CuNi .o L AE 11 MT silicone .5 TounF stationaT[ 12 83
4804 SoNiCT-SoNi . AN 11 MT silicone Glass-fiDeT .5 TounF -25C to +180C 12 83
-0C to +180C fleZinI
48047 SoPtRh-SoPt S AP 11 MT silicone IalX. steel wiTe DTaiF .5 TounF -25C to +180C 12 83
4829 Cu-CuNi .o U AC 11 MT silicone .5 TounF shoTt tiOe +200C 12 83
48048 Fe-CuNi .o L AE 12 L paTallel PVC 4.3Z7.0 oXal 7.5 9
48049 SoNiCT-SoNi . AN12 L paTallel PVC 4.3Z7.0 oXal stationaT[ 7.5 9
-25C to +70C
48050 SoPtRh-SoPt S AP 12 L paTallel PVC PVC 4.3Z7.0 oXal -10C to +80C 7.5 9
fleZinI
48270 Cu-CuNi .o U AC 12 L paTallel PVC 4.3Z7.0 oXal -5C to +70C 7.5 9
48481 Fe-CuNi J AF 12 L paTallel PVC 4.3Z7.0 oXal 7.5 9
48051 Fe-CuNi .o L AE 12 M paTallel PVC 4.2Z.8 oXal stationaT[ 12 1
48052 SoNiCT-SoNi . AN12 M paTallel PVC 4.2Z.8 oXal -25C to +70C 12 1
PVC -10C to +80C
48053 SoPtRh-SoPt S AP 12 M paTallel PVC 4.2Z.8 oXal fleZinI 12 1
48271 Cu-CuNi .o U AC 12 M paTallel PVC 4.2Z.8 oXal -5C to +70C 12 1
48054 Fe-CuNi .o L AE 13 L paTallel silicone 3.2Z5.9 oXal stationaT[ 7.5 45
48055 SoNiCT-SoNi . AN 13 L paTallel silicone 3.2Z5.9 oXal -25C to +180C 7.5 45
Glass-fiDeT -0C to +180C fleZinI
4805 SoPtRh-SoPt S AP 13 L paTallel silicone 3.2Z5.9 oXal -25C to +180C 7.5 45
48272 Cu-CuNi .o U AC 13 L paTallel silicone 3.2Z5.9 oXal shoTt tiOe +200C 7.5 45
48057 Fe-CuNi .o L AE 13 M silicone 3.5Z.0 oXal stationaT[ 12 45
48058 SoNiCT-SoNi . AN 13 M silicone 3.5Z.0 oXal -25C to +180C 12 45
Glass-fiDeT -0C to +180C fleZinI
48059 SoPtRh-SoPt S AP 13 M silicone 3.5Z.0 oXal -25C to +180C 12 45
48273 Cu-CuNi .o U AC 13 M silicone 3.5Z.0 oXal shoTt tiOe +200C 12 45
4800 Fe-CuNi .o L AE 14 L silicone Special foaOeF 11.7 TounF stationaT[ 7.5 19
4801 SoNiCT-SoNi . AN 14 L silicone silicone OiZtuTe 11.7 TounF -25C to +180C 7.5 19
-0C to +180C fleZinI
4802 SoPtRh-SoPt S AP 14 L silicone IalX. Steel hose 11.7 TounF -25C to +180C 7.5 19
48274 Cu-CuNi .o U AC 14 L silicone 11.7 TounF shoTt tiOe +200C 7.5 19
4803 Fe-CuNi .o L AE 15 L silicone 7.7 TounF 7.5 7
stationaT[
4804 SoNiCT-SoNi . AN 15 L silicone 7.7 TounF -25C to +180C 7.5 7
4805 SoPtRh-SoPt S AP 15 L silicone silicone 7.7 TounF -0C to +180C fleZinI 7.5 7
48275 Cu-CuNi .o U AC 15 L silicone 7.7 TounF -25C to +180C 7.5 7
shoTt tiOe +200C
48482 Fe-CuNi J AF 15 L silicone 7.7 TounF 7.5 7
480 Fe-CuNi .o L AE 15 LS silicone 7.8 TounF stationaT[ 7.5 105
4807 SoNiCT-SoNi . AN 15 LS silicone silicone 7.8 TounF -25C to +180C 7.5 105
-10C to +180C fleZinI
4808 SoPtRh-SoPt S AP 15 LS silicone IalX. steel wiTe DTaiF 7.8 TounF -25C to +180C 7.5 105
4827 Cu-CuNi .o U AC 15 LS silicone 7.8 TounF shoTt tiOe +200C 7.5 105
48277 Fe-CuNi .o L AE 1 L-SIL paTallel silicone 2.8Z5. oXal stationaT[ 7.5 38
48278 SoNiCT-SoNi . AN 1 L-SIL paTallel silicone 2.8Z5. oXal -25C to +180C 7.5 38
- -10C to +180C fleZinI
48279 SoPtRh-SoPt S AP 1 L-SIL paTallel silicone 2.8Z5. oXal -25C to +180C 7.5 38
48280 Cu-CuNi .o U AC 1 L-SIL paTallel silicone 2.8Z5. oXal shoTt tiOe +200C 7.5 38
48281 Fe-CuNi .o L AE 18 L +ELUFLON-FEP 4.4 TounF stationaT[ 7.5 37
48282 SoNiCT-SoNi . AN 18 L +ELUFLON-FEP 4.4 TounF -25C to +205C 7.5 37
+ELUFLON-FEP -100C to 200C
48283 SoPtRh-SoPt S AP 18 L +ELUFLON-FEP 4.4 TounF fleZinI 7.5 37
48284 Cu-CuNi .o U AC 18 L +ELUFLON-FEP 4.4 TounF -25C to +205C 7.5 37
48285 Fe-CuNi .o L AE 19 L +ELUFLON-FEP PETP tape 5. TounF stationaT[ 7.5 0
4828 SoNiCT-SoNi . AN 19 L +ELUFLON-FEP tin. Cu-TounF wiTe 5. TounF -25C to +205C 7.5 0
-100C to 200C
48287 SoPtRh-SoPt S AP 19 L +ELUFLON-FEP DTaiF 5. TounF fleZinI 7.5 0
48288 Cu-CuNi .o U AC 19 L +ELUFLON-FEP +ELUFLON-FEP 5. TounF -25C to +205C 7.5 0
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF
330
COMPENSATING CABLES
Te
71 TFa nt
3 nce
tu
43 o e
Ta
us
N cc leO
pe
C e
O
pe
Fi
n nI
t[
Ta
DI in a le e
et
.
oZ
n
tio Ta
oZ
e
cM
C te
io
: e nI
pl
pT
ith al p
la e
O pT
at
La
ou
su u T
e on
w teTi cou
Dl Fi
ap
M ap
ul
in Tat
ca en
oc
nI ti
in
s
.
aT Met
a o
Ta alla
in
MI Iht
no
Z .D
of pe
O
oT
O O
eT
TO
Te
pe
eT
eT
in
O
st
Tt
ut
ei
c
Co
Th
In
Fo
Pa
Th
O
Ja
Te
T[
O
Single-pair: 2 x 1.5 mm2 (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48289 FE-CuNi .o L AE 20 L PVC PETP tape 8.0 TounF stationaT[ 7.5 75
48290 SoNiCT-SoNi . AE 20 L PVC Dl. Cu-ITounF wiTe 8.0 TounF -25C to +70C 7.5 75
-10C to +80C
48291 SoPtRh-SoPt S AE 20 L PVC 0.5 OO 8.0 TounF fleZinI 7.5 75
48292 Cu-CuNi .o U AE 20 L PVC Alu-tapePVC 8.0 TounF -5C to +70C 7.5 75
48293 Fe-CuNi .o L AE 20 M PVC PETP tape 8.2 TounF stationaT[ 12 82
48294 SoNiCT-SoNi . AE 20 M PVC Dl. Cu-ITounF wiTe 8.2 TounF -25C to +70C 12 82
-10C to +80C
48295 SoPtRh-SoPt S AE 20 M PVC 0.5 OO 8.2 TounF fleZinI 12 82
4829 Cu-CuNi .o U AE 20 M PVC Alu-tapePVC 8.2 TounF -5C to +70C 12 82
Multiple-pair: 2 pair (4 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48100 Fe-CuNi .o L AE 9-4 L PVC 8.3 TounF 7.5 125
48101 SoNiCT-SoNi . AN 9-4 L PVC 8.3 TounF stationaT[ 7.5 125
-25C to +70C
48102 SoPtRh-SoPt S AP 9-4 L PVC PVC 8.3 TounF -10C to +80C 7.5 125
fleZinI
48297 Cu-CuNi .o U AC 9-4 L PVC 8.3 TounF -5C to +70C 7.5 125
48483 Fe-CuNi J AF 9-4 L PVC 8.3 TounF 7.5 125
48298 Fe-CuNi .o L AE 9-4 LS PVC 8.9 TounF stationaT[ 7.5 155
48299 SoNiCT-SoNi . AN 9-4 LS PVC PVC 8.9 TounF -25C to +70C 7.5 155
-10C to +80C
48300 SoPtRh-SoPt S AP 9-4 LS PVC IalX. steel wiTe DTaiF 8.9 TounF fleZinI 7.5 155
48301 Cu-CuNi .o U AC 9-4 LS PVC 8.9 TounF -5C to +70C 7.5 155
48137 Fe-CuNi .o L AE 9-4 LS< PVC 11.4 TounF stationaT[ 7.5 220
PVC
48138 SoNiCT-SoNi . AN 9-4 LS< PVC 11.4 TounF -25C to +70C 7.5 220
IalX. steel wiTe DTaiF -10C to +80C
48139 SoPtRh-SoPt S AP 9-4 LS< PVC 11.4 TounF fleZinI 7.5 220
PVC -5C to +70C
48302 Cu-CuNi .o U AC 9-4 LS< PVC 11.4 TounF 7.5 220
48303 Fe-CuNi .o L AE 9-4 MS< PVC 11.0 TounF stationaT[ 12 210
PVC
48304 SoNiCT-SoNi . AN 9-4 MS< PVC 11.0 TounF -25C to +70C 12 210
IalX. steel wiTe DTaiF -10C to +80C
48305 SoPtRh-SoPt S AP 9-4 MS< PVC 11.0 TounF fleZinI 12 210
PVC -5C to +70C
4830 Cu-CuNi .o U AC 9-4 MS< PVC 11.0 TounF 12 210
48307 Fe-CuNi .o L AE 20-4 M PVC PETP tape 10.8 TounF stationaT[ 12 137
48308 SoNiCT-SoNi
48309 SoPtRh-SoPt
. AN 20-4 M
S AP 20-4 M
PVC
PVC
Dl. Cu-ITounF wiTe 10.8
0.5 OO 10.8
TounF
TounF
-10C to +80C
-25C to +70C
fleZinI
12
12
137
137
L
48310 Cu-CuNi .o U AC 20-4 M PVC Alu-tapePVC 10.8 TounF -5C to +70C 12 137
Multiple-pair: 4 x 1.5 mm2 (L = stranded wire, conductor make-up 48 x 0.20 mm)
48474 Fe-CuNi .o L AE 11-4 LT silicone 7.8 TounF stationaT[ 7.5 11.8
48475 SoNiCT-SoNi . AE 11-4 LT silicone Glass-fiDeTIalX. steel 7.8 TounF -25C to +180C 7.5 11.8
-0C to +180C fleZinI
4847 SoPtRh-SoPt S AE 11-4 LT silicone wiTe DTaiF 7.8 TounF -25C to +180C 7.5 11.8
48477 Cu-CuNi .o U AE 11-4 LT silicone 7.8 TounF shoTt tiOe +200C 7.5 11.8
Multiple-pair: 3 pairs (6 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48103 Fe-CuNi .o L AE 9- L PVC 10.3 TounF 7.5 190
48104 SoNiCT-SoNi . AN 9- L PVC 10.3 TounF stationaT[ 7.5 190
-25C to +70C
48105 SoPtRh-SoPt S AP 9- L PVC PVC 10.3 TounF -10C to +80C 7.5 190
fleZinI
48311 Cu-CuNi .o U AC 9- L PVC 10.3 TounF -5C to +70C 7.5 190
48484 Fe-CuNi J AF 9- L PVC 10.3 TounF 7.5 190
48312 Fe-CuNi .o L AE 9- LS PVC 10.9 TounF stationaT[ 7.5 22
PVC
48313 SoNiCT-SoNi . AN 9- LS PVC 10.9 TounF -25C to +70C 7.5 2
IalX. steel wiTe DTaiF -10C to +80C
48314 SoPtRh-SoPt S AP 9- LS PVC 10.9 TounF fleZinI 7.5 22
48315 Cu-CuNi .o U AC 9- LS PVC 10.9 TounF -5C to +70C 7.5 22
48140 Fe-CuNi .o L AE 9- LS< PVC 13.4 TounF stationaT[ 7.5 292
PVC
48141 SoNiCT-SoNi . AN 9- LS< PVC 13.4 TounF -25C to +70C 7.5 292
IalX. steel wiTe DTaiF -10C to +80C
48142 SoPtRh-SoPt S AP 9- LS< PVC 13.4 TounF fleZinI 7.5 292
PVC -5C to +70C
4831 Cu-CuNi .o U AC 9- LS< PVC 13.4 TounF 7.5 292
48317 Fe-CuNi .o L AE 9- MS< PVC 12.5 TounF stationaT[ 12 272
PVC
48318 SoNiCT-SoNi . AN 9- MS< PVC 12.5 TounF -25C to +70C 12 272
IalX. steel wiTe DTaiF -10C to +80C
48319 SoPtRh-SoPt S AP 9- MS< PVC 12.5 TounF fleZinI 12 272
PVC -5C to +70C
48320 Cu-CuNi .o U AC 9- MS< PVC 12.5 TounF 12 272
48321 Fe-CuNi .o L AE 20- M PVC PETP tape 12.4 TounF stationaT[ 12 18
48322 SoNiCT-SoNi . AN 20- M PVC Dl. Cu-ITounF wiTe 12.4 TounF -25C to +70C 12 18
-10C to +80C
48323 SoPtRh-SoPt S AP 20- M PVC 0.5 OO 12.4 TounF fleZinI 12 18
48324 Cu-CuNi .o U AC 20- M PVC Alu-tapePVC 12.4 TounF -5C to +70C 12 18
Multiple-pair: 4 pairs (8 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm
4810 Fe-CuNi .o L AE 9-8 L PVC 11.0 TounF 7.5 238
48107 SoNiCT-SoNi . AN 9-8 L PVC 11.0 TounF stationaT[ 7.5 238
-25C to +70C
48108 SoPtRh-SoPt S AP 9-8 L PVC PVC 11.0 TounF -10C to +80C 7.5 238
fleZinI
48325 Cu-CuNi .o U AC 9-8 L PVC 11.0 TounF -5C to +70C 7.5 238
48485 Fe-CuNi J AF 9-8 L PVC 11.0 TounF 7.5 238
48143 Fe-CuNi .o L AE 9-8 LS< PVC 14.0 TounF stationaT[ 7.5 410
PVC
48144 SoNiCT-SoNi . AN 9-8 LS< PVC 14.0 TounF -25C to +70C 7.5 410
IalX. steel wiTe DTaiF -10C to +80C
48145 SoPtRh-SoPt S AP 9-8 LS< PVC 14.0 TounF fleZinI 7.5 410
PVC -5C to +70C
4832 Cu-CuNi .o U AC 9-8 LS< PVC 14.0 TounF 7.5 410
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF
331
COMPENSATING CABLES
Te
71 TFa nt
3 nce
tu
43 o e
Ta
us
N cc leO
pe
C e
O
pe
Fi
n nI
t[
Ta
DI in a le e
et
.
oZ
n
tio Ta
oZ
e
cM
C te
io
: e nI
pl
pT
ith al p
la e
O pT
at
La
ou
su uT
e on
w teTi cou
Dl Fi
ap
M ap
ul
in Tat
ca en
oc
nI ti
in
s
.
aT Met
a o
Ta alla
in
MI Iht
no
Z .D
of pe
O
oT
O O
eT
TO
Te
pe
eT
eT
in
O
st
Tt
ut
ei
c
Co
Th
In
Fo
Pa
Th
O
Ja
Te
T[
O
Multiple-pair: 5 pairs (10 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm
48109 FE-CuNi .o L AE 9-10 L PVC 13.0 TounF 7.5 284
48110 SoNiCT-SoNi . AN 9-10 L PVC 13.0 TounF stationaT[ 7.5 284
48111 SoPtRh-SoPt S AP 9-10 L PVC 13.0 TounF -10C to +80C -25C to +70C 7.5 284
PVC
fleZinI
48327 Cu-CuNi .o U AC 9-10 L PVC 13.0 TounF -5C to +70C 7.5 284
4848 FE-CuNi .o J AF 9-10 L PVC 13.0 TounF 7.5 284
4814 Fe-CuNi .o L AE 9-10 LS< PVC 1.5 TounF stationaT[ 7.5 475
PVC
48147 SoNiCT-SoNi . AN 9-10 LS< PVC 1.5 TounF -25C to +70C 7.5 475
IalX. steel wiTe DTaiF -10C to +80C
48148 SoPtRh-SoPt S AP 9-10 LS< PVC 1.5 TounF fleZinI 7.5 475
PVC -5C to +70C
48328 Cu-CuNi .o U AC 9-10 LS< PVC 1.5 TounF 7.5 475
Multiple-pair: 6 pairs (12 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48112 Fe-CuNi .o L AE 9-12 L PVC 13.5 TounF 7.5 320
48113 SoNiCT-SoNi . AN 9-12 L PVC 13.5 TounF stationaT[ 7.5 320
-25C to +70C
48114 SoPtRh-SoPt S AP 9-12 L PVC PVC 13.5 TounF -10C to +80C 7.5 320
fleZinI
48329 Cu-CuNi .o U AC 9-12 L PVC 13.5 TounF -5C to +70C 7.5 320
48487 Fe-CuNi J AF 9-12 L PVC 13.5 TounF 7.5 320
48330 Fe-CuNi .o L AE 9-12 LS PVC 14.2 TounF stationaT[ 7.5 384
48331 SoNiCT-SoNi . AN 9-12 LS PVC PVC 14.2 TounF -25C to +70C 7.5 384
-10C to +80C
48332 SoPtRh-SoPt S AP 9-12 LS PVC IalX. steel wiTe DTaiF 14.2 TounF fleZinI 7.5 384
48333 Cu-CuNi .o U AC 9-12 LS PVC 14.2 TounF -5C to +70C 7.5 384
48149 Fe-CuNi .o L AE 9-12 LS< PVC 17.5 TounF stationaT[ 7.5 483
PVC
48150 SoNiCT-SoNi . AN 9-12 LS< PVC 17.5 TounF -25C to +70C 7.5 483
IalX. steel wiTe DTaiF -10C to +80C
48151 SoPtRh-SoPt S AP 9-12 LS< PVC 17.5 TounF fleZinI 7.5 483
PVC -5C to +70C
48334 Cu-CuNi .o U AC 9-12 LS< PVC 17.5 TounF 7.5 483
48335 Fe-CuNi .o L AE 9-12 MS< PVC 1.5 TounF stationaT[ 12 478
PVC
4833 SoNiCT-SoNi . AN 9-12 MS< PVC 1.5 TounF -25C to +70C 12 478
IalX. steel wiTe DTaiF -10C to +80C
48337 SoPtRh-SoPt S AP 9-12 MS< PVC 1.5 TounF fleZinI 12 478
PVC -5C to +70C
48338 Cu-CuNi .o U AC 9-12 MS< PVC 1.5 TounF 12 478
48339 Fe-CuNi .o L AE 20-12 M PVC PETP tape 1.3 TounF stationaT[ 12 32
48340 SoNiCT-SoNi . AN 20-12 M PVC Dl. Cu-ITounF wiTe 1.3 TounF -25C to +70C 12 32
-10C to +80C
48341 SoPtRh-SoPt S AP 20-12 M PVC 0.5 OO 1.3 TounF fleZinI 12 32
48342 Cu-CuNi .o U AC 20-12 M PVC
Alu-tapePVC
1.3 TounF -5C to +70C 12 32
Multiple-pair: 7 pairs (14 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm
48115 Fe-CuNi .o L AE 9-14 L PVC 14.5 TounF 7.5 39
4811 SoNiCT-SoNi . AN 9-14 L PVC 14.5 TounF stationaT[ 7.5 39
-25C to +70C
48117 SoPtRh-SoPt S AP 9-14 L PVC PVC 14.5 TounF -10C to +80C 7.5 39
fleZinI
48343 Cu-CuNi .o U AC 9-14 L PVC 14.5 TounF -5C to +70C 7.5 39
48488 Fe-CuNi J AF 9-14 L PVC 14.5 TounF 7.5 39
48152 Fe-CuNi .o L AE 9-14 LS< PVC 18.5 TounF stationaT[ 7.5 40
48153 SoNiCT-SoNi . AN 9-14 LS< PVC PVC 18.5 TounF 7.5 40
-25C to +70C
IalX. steel wiTe DTaiF -10C to +80C
48154 SoPtRh-SoPt S AP 9-14 LS< PVC 18.5 TounF fleZinI 7.5 40
PVC -5C to +70C
48344 Cu-CuNi .o U AC 9-14 LS< PVC 18.5 TounF 7.5 40
Multiple-pair: 8 pairs (16 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48118 Fe-CuNi .o L AE 9-1 L PVC 15.1 TounF 7.5 419
48119 SoNiCT-SoNi . AN 9-1 L PVC 15.1 TounF stationaT[ 7.5 419
-25C to +70C
48120 SoPtRh-SoPt S AP 9-1 L PVC PVC 15.1 TounF -10C to +80C 7.5 419
fleZinI
48345 Cu-CuNi .o U AC 9-1 L PVC 15.1 TounF -5C to +70C 7.5 419
48489 Fe-CuNi J AF 9-1 L PVC 15.1 TounF 7.5 419
4834 Fe-CuNi .o L AE 9-1 LS PVC 1.1 TounF stationaT[ 7.5 495
PVC
48347 SoNiCT-SoNi . AN 9-1 LS PVC 1.1 TounF -25C to +70C 7.5 495
IalX. steel wiTe -10C to +80C
48348 SoPtRh-SoPt S AP 9-1 LS PVC 1.1 TounF fleZinI 7.5 495
DTaiF -5C to +70C
48349 Cu-CuNi .o U AC 9-1 LS PVC 1.1 TounF 7.5 495
48155 Fe-CuNi .o L AE 9-1 LS< PVC 19.3 TounF stationaT[ 7.5 23
PVCIalX.
4815 SoNiCT-SoNi . AN 9-1 LS< PVC 19.3 TounF -25C to +70C 7.5 23
steel wiTe DTaiF -10C to +80C
48157 SoPtRh-SoPt S AP 9-1 LS< PVC 19.3 TounF fleZinI 7.5 23
PVC -5C to +70C
48350 Cu-CuNi .o U AC 9-1 LS< PVC 19.3 TounF 7.5 23
48351 Fe-CuNi .o L AE 9-1 MS< PVC 18.7 TounF stationaT[ 12 1
PVCIalX.
48352 SoNiCT-SoNi . AN 9-1 MS< PVC 18.7 TounF -25C to +70C 12 1
steel wiTe DTaiF -10C to +80C
48353 SoPtRh-SoPt S AP 9-1 MS< PVC 18.7 TounF fleZinI 12 1
PVC -5C to +70C
48354 Cu-CuNi .o U AC 9-1 MS< PVC 18.7 TounF 12 1
48355 Fe-CuNi .o L AE 20-1 M PVC PETP tape 1.8 TounF stationaT[ 12 423
4835 SoNiCT-SoNi . AN 20-1 M PVC Dl. Cu-ITounF wiTe 1.8 TounF -25C to +70C 12 423
-10C to +80C
48357 SoPtRh-SoPt S AP 20-1 M PVC 0.5 OO 1.8 TounF fleZinI 12 423
48358 Cu-CuNi .o U AC 20-1 M PVC
Alu-tapePVC
1.8 TounF -5C to +70C 12 423
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF
332
COMPENSATING CABLES
Te
71 TFa nt
3 nce
tu
43 o e
Ta
us
N cc leO
pe
C e
O
pe
Fi
n nI
t[
Ta
DI in a le e
et
.
oZ
n
tio Ta
oZ
e
cM
C te
io
: e nI
pl
pT
ith al p
la e
O pT
at
La
ou
su u T
e on
w teTi cou
Dl Fi
ap
M ap
ul
in Tat
ca en
oc
nI ti
in
s
.
aT Met
a o
Ta alla
in
MI Iht
no
Z .D
of pe
O
oT
O O
eT
TO
Te
pe
eT
eT
in
O
st
Tt
ut
ei
c
Co
Th
In
Fo
Pa
Th
O
Ja
Te
T[
O
Multiple-pair: 9 pairs (18 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm
48121 FE-CuNi .o L AE 9-18 L PVC 1.5 TounF 7.5 480
stationaT[
48122 SoNiCT-SoNi . AE 9-18 L PVC 1.5 TounF 7.5 480
-25C to +70C
48123 SoPtRh-SoPt S AE 9-18 L PVC PVC 1.5 TounF -10C to +80C 7.5 480
fleZinI
48359 Cu-CuNi .o U AE 9-18 L PVC 1.5 TounF 7.5 480
-5C to +70C
48490 FE-CuNi J AF 9-18 L PVC 1.5 TounF 7.5 480
48158 Fe-CuNi .o L AE 9-18 LS< PVC 20.5 TounF stationaT[ 7.5 758
PVC
48159 SoNiCT-SoNi . AE 9-18 LS< PVC 20.5 TounF -25C to +70C 7.5 758
IalX. steel wiTe DTaiF -10C to +80C
4810 SoPtRh-SoPt S AE 9-18 LS< PVC 20.5 TounF fleZinI 7.5 758
PVC
4830 Cu-CuNi .o U AE 9-18 LS< PVC 20.5 TounF -5C to +70C 7.5 758
Multiple-pair: 10 pairs (20 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48124 Fe-CuNi .o L AE 9-20 L PVC 1.7 TounF 7.5 520
stationaT[
48125 SoNiCT-SoNi . AN 9-20 L PVC 1.7 TounF 7.5 520
-25C to +70C
4812 SoPtRh-SoPt S AP 9-20 L PVC PVC 1.7 TounF -10C to +80C 7.5 520
fleZinI
4831 Cu-CuNi .o U AC 9-20 L PVC 1.7 TounF 7.5 520
-5C to +70C
48491 Fe-CuNi J AF 9-20 L PVC 1.7 TounF 7.5 520
4832 Fe-CuNi .o L AE 9-20 LS PVC 17.7 TounF stationaT[ 7.5 13
4833 SoNiCT-SoNi . AN 9-20 LS PVC PVC 17.7 TounF -25C to +70C 7.5 13
-10C to +80C
4834 SoPtRh-SoPt S AP 9-20 LS PVC IalX. steel wiTe DTaiF 17.7 TounF fleZinI 7.5 13
4835 Cu-CuNi .o U AC 9-20 LS PVC 17.7 TounF -5C to +70C 7.5 13
4811 Fe-CuNi .o L AE 9-20 LS< PVC 20.9 TounF stationaT[ 7.5 752
PVC
4812 SoNiCT-SoNi . AN 9-20 LS< PVC 20.9 TounF -25C to +70C 7.5 752
IalX. steel wiTe DTaiF -10C to +80C
4813 SoPtRh-SoPt S AP 9-20 LS< PVC 20.9 TounF fleZinI 7.5 752
PVC
483 Cu-CuNi .o U AC 9-20 LS< PVC 20.9 TounF -5C to +70C 7.5 752
4837 Fe-CuNi .o L AE 9-20 MS< PVC 20.3 TounF stationaT[ 12 744
PVC
4838 SoNiCT-SoNi . AN 9-20 MS< PVC 20.3 TounF -25C to +70C 12 744
IalX. steel wiTe DTaiF -10C to +80C
4839 SoPtRh-SoPt S AP 9-20 MS< PVC 20.3 TounF fleZinI 12 744
PVC
48370 Cu-CuNi .o U AC 9-20 MS< PVC 20.3 TounF -5C to +70C 12 744
48371 Fe-CuNi .o
48372 SoNiCT-SoNi
L AE 20-20 M
. AN 20-20 M
PVC
PVC
PETP tape
Dl. Cu-ITounF wiTe 20.3
20.3 TounF
TounF
-10C to +80C
stationaT[
-25C to +70C
12
12
542
542 L
48373 SoPtRh-SoPt S AP 20-20 M PVC 0.5 OO 20.3 TounF fleZinI 12 542
48374 Cu-CuNi .o U AC 20-20 M PVC Alu-tapePVC 20.3 TounF -5C to +70C 12 542
Multiple-pair: 12 pairs (24 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48127 Fe-CuNi .o L AE 9-24 L PVC 19.0 TounF 7.5 14
stationaT[
48128 SoNiCT-SoNi . AN 9-24 L PVC 19.0 TounF 7.5 14
-25C to +70C
48129 SoPtRh-SoPt S AP 9-24 L PVC PVC 19.0 TounF -10C to +80C 7.5 14
fleZinI
48375 Cu-CuNi .o U AC 9-24 L PVC 19.0 TounF 7.5 14
-5C to +70C
48492 Fe-CuNi J AF 9-24 L PVC 19.0 TounF 7.5 14
4837 Fe-CuNi .o L AE 9-24 LS PVC 20.2 TounF stationaT[ 7.5 738
48377 SoNiCT-SoNi . AN 9-24 LS PVC PVC 20.2 TounF -25C to +70C 7.5 738
-10C to +80C
48378 SoPtRh-SoPt S AP 9-24 LS PVC IalX. steel wiTe DTaiF 20.2 TounF fleZinI 7.5 738
48379 Cu-CuNi .o U AC 9-24 LS PVC 20.2 TounF -5C to +70C 7.5 738
4814 Fe-CuNi .o L AE 9-24 LS< PVC 24.2 TounF stationaT[ 7.5 938
PVC
4815 SoNiCT-SoNi . AN 9-24 LS< PVC 24.2 TounF -25C to +70C 7.5 938
IalX. steel wiTe DTaiF -10C to +80C
481 SoPtRh-SoPt S AP 9-24 LS< PVC 24.2 TounF fleZinI 7.5 938
PVC
48380 Cu-CuNi .o U AC 9-24 LS< PVC 24.2 TounF -5C to +70C 7.5 938
48381 Fe-CuNi .o L AE 9-24 MS< PVC 23.1 TounF stationaT[ 12 907
PVC
48382 SoNiCT-SoNi . AN 9-24 MS< PVC 23.1 TounF -25C to +70C 12 907
IalX. steel wiTe DTaiF -10C to +80C
48383 SoPtRh-SoPt S AP 9-24 MS< PVC 23.1 TounF fleZinI 12 907
PVC
48384 Cu-CuNi .o U AC 9-24 MS< PVC 23.1 TounF -5C to +70C 12 907
48385 Fe-CuNi .o L AE 20-24 M PVC PETP tape 22.5 TounF stationaT[ 12 38
4838 SoNiCT-SoNi . AN 20-24 M PVC Dl. Cu-ITounF wiTe 22.5 TounF -25C to +70C 12 38
-10C to +80C
48387 SoPtRh-SoPt S AP 20-24 M PVC 0.5 OO 22.5 TounF fleZinI 12 38
48388 Cu-CuNi .o U AC 20-24 M PVC Alu-tapePVC 22.5 TounF -5C to +70C 12 38
Multiple-pair: 16 pairs (32 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48389 Fe-CuNi .o L AE 9-32 L PVC 20.9 TounF 7.5 793
48390 SoNiCT-SoNi . AN 9-32 L PVC 20.9 TounF stationaT[ 7.5 793
-25C to +70C
48391 SoPtRh-SoPt S AP 9-32 L PVC PVC 20.9 TounF -10C to +80C 7.5 793
fleZinI
48392 Cu-CuNi .o U AC 9-32 L PVC 20.9 TounF 7.5 793
-5C to +70C
48493 Fe-CuNi J AF 9-32 L PVC 20.9 TounF 7.5 793
48393 Fe-CuNi .o L AE 9-32 LS PVC 22.1 TounF stationaT[ 7.5 923
48394 SoNiCT-SoNi . AN 9-32 LS PVC PVC 22.1 TounF -25C to +70C 7.5 923
-10C to +80C
48395 SoPtRh-SoPt S AP 9-32 LS PVC IalX. steel wiTe DTaiF 22.1 TounF fleZinI 7.5 923
4839 Cu-CuNi .o U AC 9-32 LS PVC 22.1 TounF -5C to +70C 7.5 923
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF
333
COMPENSATING CABLES
Te
71 TFa nt
3 nce
tu
43 o e
Ta
us
N cc leO
pe
C e
O
pe
Fi
n nI
t[
Ta
DI in a le e
et
.
oZ
n
tio Ta
oZ
e
cM
C te
io
: e nI
pl
pT
ith al p
la e
O pT
at
La
ou
su uT
e on
w teTi cou
Dl Fi
ap
M ap
ul
in Tat
ca en
oc
nI ti
in
s
.
aT Met
a o
Ta alla
in
MI Iht
no
Z .D
of pe
O
oT
O O
eT
TO
Te
pe
eT
eT
in
O
st
Tt
ut
ei
c
Co
Th
In
Fo
Pa
Th
O
Ja
Te
T[
O
Multiple-pair: 16 pairs (32 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48397 FE-CuNi .o L AE 9-32 LS< PVC 2.1 TounF stationaT[ 7.5 1141
PVC
48398 SoNiCT-SoNi . AN 9-32 LS< PVC 2.1 TounF -25C to +70C 7.5 1141
IalX. steel wiTe DTaiF -10C to +80C
48399 SoPtRh-SoPt S AP 9-32 LS< PVC 2.1 TounF fleZinI 7.5 1141
PVC -5C to +70C
48400 Cu-CuNi .o U AC 9-32 LS< PVC 2.1 TounF 7.5 1141
48401 Fe-CuNi .o L AE 9-32 MS< PVC 25.3 TounF stationaT[ 12 1130
PVC
48402 SoNiCT-SoNi . AN 9-32 MS< PVC 25.3 TounF -25C to +70C 12 1130
IalX. steel wiTe DTaiF -10C to +80C
48403 SoPtRh-SoPt S AP 9-32 MS< PVC 25.3 TounF fleZinI 12 1130
PVC -5C to +70C
48404 Cu-CuNi .o U AC 9-32 MS< PVC 25.3 TounF 12 1130
48405 Fe-CuNi .o L AE 20-32 M PVC PETP-tape 25.1 TounF stationaT[ 12 847
4840 SoNiCT-SoNi . AN 20-32 M PVC Dl. Cu-ITounF wiTe 25.1 TounF -25C to +70C 12 847
-10C to +80C
48407 SoPtRh-SoPt S AP 20-32 M PVC 0.5 OO 25.1 TounF fleZinI 12 847
48408 Cu-CuNi .o U AC 20-32 M PVC Alu-tapePVC 25.1 TounF -5C to +70C 12 847
Multiple-pair: 18 pair (36 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48130 Fe-CuNi .o L AE 9-3 L PVC 22.1 TounF 7.5 904
48132 SoNiCT-SoNi . AN 9-3 L PVC 22.1 TounF stationaT[ 7.5 904
-25C to +70C
48133 SoPtRh-SoPt S AP 9-3 L PVC PVC 22.1 TounF -10C to +80C 7.5 904
fleZinI
48409 Cu-CuNi .o U AC 9-3 L PVC 22.1 TounF -5C to +70C 7.5 904
48494 Fe-CuNi J AF 9-3 L PVC 22.1 TounF 7.5 904
48410 Fe-CuNi .o L AE 9-3 LS PVC 23.3 TounF stationaT[ 7.5 1040
PVC
48411 SoNiCT-SoNi . AN 9-3 LS PVC 23.3 TounF -25C to +70C 7.5 1040
IalX. steel wiTe -10C to +80C
48412 SoPtRh-SoPt S AP 9-3 LS PVC 23.3 TounF fleZinI 7.5 1040
DTaiF -5C to +70C
48413 Cu-CuNi .o U AC 9-3 LS PVC 23.3 TounF 7.5 1040
4817 Fe-CuNi .o L AE 9-3 LS< PVC 27.3 TounF stationaT[ 7.5 128
PVC
4819 SoNiCT-SoNi . AN 9-3 LS< PVC 27.3 TounF -25C to +70C 7.5 128
IalX. steel wiTe DTaiF -10C to +80C
48170 SoPtRh-SoPt S AP 9-3 LS< PVC 27.3 TounF fleZinI 7.5 128
PVC -5C to +70C
48414 Cu-CuNi .o U AC 9-3 LS< PVC 27.3 TounF 7.5 128
48415 Fe-CuNi .o L AE 9-3 MS< PVC 2.1 TounF stationaT[ 12 1232
PVC
4841 SoNiCT-SoNi . AN 9-3 MS< PVC 2.1 TounF -25C to +70C 12 1232
IalX. steel wiTe DTaiF -10C to +80C
48417 SoPtRh-SoPt S AP 9-3 MS< PVC 2.1 TounF fleZinI 12 1232
PVC -5C to +70C
48418 Cu-CuNi .o U AC 9-3 MS< PVC 2.1 TounF 12 1232
48419 Fe-CuNi .o L AE 20-3 M PVC PETP-tape 2.0 TounF stationaT[ 12 944
48420 SoNiCT-SoNi . AN 20-3 M PVC Dl. Cu-ITounF wiTe 2.0 TounF -25C to +70C 12 944
-10C to +80C
48421 SoPtRh-SoPt S AP 20-3 M PVC 0.5 OO 2.0 TounF fleZinI 12 944
48422 Cu-CuNi .o U AC 20-3 M PVC Alu-tapePVC 2.0 TounF -5C to +70C 12 944
Multiple-pair: 19 pairs (38 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm)
48134 Fe-CuNi .o L AE 9-38 L PVC 22.5 TounF stationaT[ 7.5 937
48135 SoNiCT-SoNi . AN 9-38 L PVC 22.5 TounF -25C to +70C 7.5 937
PVC -10C to +80C
4813 SoPtRh-SoPt S AP 9-38 L PVC 22.5 TounF fleZinI 7.5 937
48423 Cu-CuNi .o U AC 9-38 L PVC 22.5 TounF -5C to +70C 7.5 937
48171 Fe-CuNi .o L AE 9-38 LS< PVC 2.5 TounF stationaT[ 7.5 1340
PVC
48172 SoNiCT-SoNi . AN 9-38 LS< PVC 2.5 TounF -25C to +70C 7.5 1340
IalX. steel wiTe DTaiF -10C to +80C
48173 SoPtRh-SoPt S AP 9-38 LS< PVC 2.5 TounF fleZinI 7.5 1340
PVC -5C to +70C
48424 Cu-CuNi .o U AC 9-38 LS< PVC 2.5 TounF 7.5 1340
Multiple-pair: 20 pairs (40 x 1.5 mm2) (L = stranded wire, conductor make-up 48 x 0.20 mm; M = solid conductor, conductor 1.38 mm)
48425 Fe-CuNi .o L AE 9-40 L PVC 24.1 TounF stationaT[ 7.5 1032
4842 SoNiCT-SoNi . AN 9-40 L PVC 24.1 TounF -25C to +70C 7.5 1032
PVC -10C to +80C
48427 SoPtRh-SoPt S AP 9-40 L PVC 24.1 TounF fleZinI 7.5 1032
48428 Cu-CuNi .o U AC 9-40 L PVC 24.1 TounF -5C to +70C 7.5 1032
48429 Fe-CuNi .o L AE 9-40 LS PVC 25.3 TounF stationaT[ 7.5 1200
48430 SoNiCT-SoNi . AN 9-40 LS PVC PVC 25.3 TounF -25C to +70C 7.5 1200
-10C to +80C
48431 SoPtRh-SoPt S AP 9-40 LS PVC IalX. steel wiTe DTaiF 25.3 TounF fleZinI 7.5 1200
48432 Cu-CuNi .o U AC 9-40 LS PVC 25.3 TounF -5C to +70C 7.5 1200
48433 Fe-CuNi .o L AE 9-40 LS< PVC 29.3 TounF stationaT[ 7.5 144
PVC
48434 SoNiCT-SoNi . AN 9-40 LS< PVC 29.3 TounF -25C to +70C 7.5 144
IalX. steel wiTe DTaiF -10C to +80C
48435 SoPtRh-SoPt S AP 9-40 LS< PVC 29.3 TounF fleZinI 7.5 144
PVC -5C to +70C
4843 Cu-CuNi .o U AC 9-40 LS< PVC 29.3 TounF 7.5 144
48437 Fe-CuNi .o L AE 9-40 MS< PVC 28.0 TounF stationaT[ 12 1381
PVC
48438 SoNiCT-SoNi . AN 9-40 MS< PVC 28.0 TounF -25C to +70C 12 1381
IalX. steel wiTe DTaiF -10C to +80C
48439 SoPtRh-SoPt S AP 9-40 MS< PVC 28.0 TounF fleZinI 12 1381
PVC -5C to +70C
48440 Cu-CuNi .o U AC 9-40 MS< PVC 28.0 TounF 12 1381
48441 Fe-CuNi .o L AE 9-40M PVC PETP-tape 2.0 TounF stationaT[ 12 1001
48442 SoNiCT-SoNi . AN 9-40 M PVC Dl. Cu-ITounF wiTe 2.0 TounF -25C to +70C 12 1001
-10C to +80C
48443 SoPtRh-SoPt S AP 9-40 M PVC 0.5 OO Alu-tape 2.0 TounF fleZinI 12 1001
48444 Cu-CuNi .o U AC 9-40 M PVC PVC 2.0 TounF -5C to +70C 12 1001
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF
334
COMPENSATING CABLES
Te
71 TFa nt
3 nce
tu
43 o e
Ta
us
N cc leO
pe
C e
O
pe
Fi
n nI
t[
Ta
DI in a le e
et
.
oZ
n
tio Ta
oZ
e
cM
C te
io
: e nI
pl
pT
ith al p
la e
O pT
at
La
ou
su u T
e on
w teTi cou
Dl Fi
ap
M ap
ul
in Tat
ca en
oc
nI ti
in
s
.
aT Met
a o
Ta alla
in
MI Iht
no
Z .D
of pe
O
oT
O O
eT
TO
Te
pe
eT
eT
in
O
st
Tt
ut
ei
c
Co
Th
In
Fo
Pa
Th
O
Ja
Te
T[
O
Single-pair: 2 x 0.22 mm2 (L = stranded wire, conductor make-up 7 x 0.20 mm)
48200 FE-CuNi .o L AE 1 L PVC 1.0 TounF stationaT[ 7.5 10
48201 SoNiCT-SoNi . AE 1 L PVC 1.0 TounF -25C to +70C 7.5 10
- -10C to +80C
48202 SoPtRh-SoPt S AE 1 L PVC 1.0 TounF fleZinI 7.5 10
4840 Cu-CuNi .o U AE 1 L PVC 1.0 TounF -5C to +70C 7.5 10
Single-pair: 2 x 0.22 mm2 (L = stranded wire, conductor make-up 7 x 0.20 mm)
48203 Fe-CuNi .o L AE 9-022 PVC 4.0 TounF stationaT[ 7.5 22
48204 SoNiCT-SoNi . AE 9-022 PVC 4.0 TounF -25C to +70C 7.5 22
PVC -10C to +80C
48205 SoPtRh-SoPt S AE 9-022 PVC 4.0 TounF fleZinI 7.5 22
4841 Cu-CuNi .o U AE 9-022 PVC 4.0 TounF -5C to +70C 7.5 22
4820 Fe-CuNi .o L AE 5-022 PVC PETP tape 4.9 TounF stationaT[ 7.5 31
48207 SoNiCT-SoNi . AN 5-022 PVC IalX. Cu-TounF 4.9 TounF -25C to +70C 7.5 31
-10C to +80C
48208 SoPtRh-SoPt S AP 5-022 PVC wiTe DTaiF 4.9 TounF fleZinI 7.5 31
4842 Cu-CuNi .o U AC 5-022 PVC PVC 4.9 TounF -5C to +70C 7.5 31
4843 Fe-CuNi .o L AE 15-022 Ilass-DeT 3.4 TounF stationaT[ 7.5 1
4844 SoNiCT-SoNi . AN 15-022 Ilass-DeT 3.4 TounF -25C to +180C 7.5 1
fleZinI
4845 SoPtRh-SoPt S AP 15-022 Ilass-DeT silicone 3.4 TounF -40C to +200C 7.5 1
-25C to +180C
484 Cu-CuNi .o U AC 15-022 Ilass-DeT 3.4 TounF shoTt tiOe 7.5 1
+200C
48209 Fe-CuNi .o L AE 15-G 022 Ilass-DeT 3.9 TounF stationaT[ 7.5 22
48210 SoNiCT-SoNi . AN 15-G 022 Ilass-DeT 3.9 TounF -25C to +180C 7.5 22
fleZinI
48211 SoPtRh-SoPt S AP 15-G 022 Ilass-DeT siliconeIlass-fiDeT 3.9 TounF -40C to +200C 7.5 22
-25C to +180C
4847 Cu-CuNi .o U AC 15-G 022 Ilass-DeT 3.9 TounF shoTt tiOe 7.5 22
+200C
48212 Fe-CuNi .o L AE GI-SIL-GI-S Ilass-DeT 5.0 TounF stationaT[ 7.5 25
silicone -25C to +180C
48213 SoNiCT-SoNi . AN GI-SIL-GI-S Ilass-DeT 5.0 TounF 7.5 25
Glass-fiDeT -40C to +200C fleZinI
48214 SoPtRh-SoPt S AP GI-SIL-GI-S Ilass-DeT 5.0 TounF -25C to +180C 7.5 25
IalX. steel wiTe DTaiF
4848 Cu-CuNi .o U AC GI-SIL-GI-S Ilass-DeT 5.0 TounF shoTt tiOe +200C 7.5 25
Single-pair: 2 x 0.5 mm2 (L = stranded wire, conductor make-up 16 x 0.20 mm)
48215 Fe-CuNi .o
4821 SoNiCT-SoNi
L AE GI-SIL
. AN GI-SIL
Ilass-DeT
Ilass-DeT
4.
4.
TounF
TounF
stationaT[
-25C to +200C
7.5
7.5
18
18
L
silicone -40C to +200C
48217 SoPtRh-SoPt S AP GI-SIL Ilass-DeT 4. TounF fleZinI 7.5 18
4849 Cu-CuNi .o U AC GI-SIL Ilass-DeT 4. TounF -25C to +200C 7.5 18
Single-pair: 2 x 0.75 mm2 (L = stranded wire, conductor make-up 24 x 0.20 mm)
48218 Fe-CuNi .o L AE PVC-PVC PVC .0 TounF stationaT[ 7.5 25
48219 SoNiCT-SoNi . AN PVC-PVC PVC .0 TounF -25C to +70C 7.5 25
PVC -10C to +80C
48220 SoPtRh-SoPt S AP PVC-PVC PVC .0 TounF fleZinI 7.5 25
48470 Cu-CuNi .o U AC PVC-PVC PVC .0 TounF -5C to +70C 7.5 25
Multiple-pair: 4 x 0.22 mm2 (stranded wire, conductor make-up 7 x 0.20 mm)
48221 Fe-CuNi .o L AE PVC-PVC PVC .0 TounF stationaT[ 7.5 33
48222 SoNiCT-SoNi . AN PVC-PVC PVC .0 TounF -20C to +80C 7.5 33
PVC -10C to +80C
48223 SoPtRh-SoPt S AP PVC-PVC PVC .0 TounF fleZinI 7.5 33
48471 Cu-CuNi .o U AC PVC-PVC PVC .0 TounF -5C to +80C 7.5 33
48224 Fe-CuNi .o L AE PVC-C-PVC PVC .0 TounF stationaT[ 7.5 37
IalX.
48225 SoNiCT-SoNi . AN PVC-C-PVC PVC .0 TounF -20C to +80C 7.5 37
Cu-DTaiF -10C to +80C
4822 SoPtRh-SoPt S AP PVC-C-PVC PVC .0 TounF fleZinI 7.5 37
PVC LacMet
48472 Cu-CuNi .o U AC PVC-C-PVC PVC .0 TounF -5C to +80C 7.5 37
48227 Fe-CuNi .o L AE GIL-SIL Ilass-DeT .0 TounF stationaT[ 7.5 35
48228 SoNiCT-SoNi . AN GIL-SIL Ilass-DeT .0 TounF -25C to +180C 7.5 35
silicone -40C to +200C
48229 SoPtRh-SoPt S AP GIL-SIL Ilass-DeT .0 TounF fleZinI 7.5 35
48473 Cu-CuNi .o U AC GIL-SIL Ilass-DeT .0 TounF -25C to +180C 7.5 35
L stTanFeF conFuctoT
M soliF conFuctoT
tin. tinneF
IalX. IalXani\eF
335
COAXIAL CABLES
CATV-Cables 342
Multimedia-Coaxial Cables SAT 1,0/4,6GH, up to 2400MHz, for digital-tv, double screened, screening efficieny >90dB 344
SAT-Coaxial Cables for digital-tv, screening efficieny >90dB / >95dB, for satellite-receivers, double screened 345
337
Coaxial Cables
RG-Coaxial Cables
Cable structure
Inner conductor diameter mm 1 x 0,7 7 x 0,4 19 x 0,2 1 x 0,6 1 x 0,6 1 x 0,6
Steel/copper, bare Tinned copper Tinned copper Steel/copper, bare Steel/copper, bare Steel/copper, bare
Insulation mm 4,7 PE 7,3 PE 2,95 PE 3,7 PE 3,7 PE, hollow 3,7 PE, hollow
Outer conductor 2 braids Braid Braid Braid Braid 2 braids
Silvered copper Copper, bare Tinned copper Copper, bare Copper, bare Copper, bare
Copper, bare - - - - Tinned copper
Outer sheath PVC PVC PVC PVC PVC PVC
Min. bending radius approx. mm 40 50 25 30 30 30
Temperature range C -35 to +80 -35 to +80 -35 to +80 -35 to +80 -35 to +80 -50 to +70
Copper weight kg/km 72,0 58,0 29,0 28,0 28,0 48,0
Outer approx. mm 8,4 10,3 5,0 6,2 6,2 6,2
Weight approx. kg / km 115 140 38 57 52 62
Electrical characteristics
Impedance (Ohm) 75 3 75 3 50 2 75 3 93 5 93 3
Frequency range
f (max.) GHz 3 3 3 3 3 3
Propagation velocity v/c 0,7 0,7 0,7 0,7 0,8 0,8
Attenuation at 20C
(db/100m)
100 MHz 8,8 7,5 17 11,5 10,5 10,5
200 MHz 13,5 11 24 16,5 15 15
500 MHz 21 18,5 39 27 24,5 24,5
800 MHz 27,5 24 51 35 32,5 32,5
1000 MHz - 30 56 41 35 -
1350 MHz - - - - - -
1750 MHz - - - - - -
CapacitancepF/m 67 67 101 67 42,5 42,5
Rel. velocity of propagation % 67 67 67 67 83 83
Insulation resistance
MOhm x kmmin. 10
5
10
5
10
5
10
5
10
5
10
5
Loop resistance
max. (Ohm/km) 110 23 53 171 155 136
Nominal peak voltagekVs 3 5 2 4 1 2
Dielectric strength
50 HzkVeff 7 10 5 7 3 3
Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility
Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions. The varied
mechanical, thermal and electronic properties of Coaxial cables mean that they can be used up into the GHz levels, as per cable type.
338
Coaxial Cables
RG-Coaxial Cables
Type RG 174 A/U RG 174 U RG 178 B/U RG 179 B/U RG 180 B/U RG 187 A/U
Part no. 40197 400189 40007 40008 40009 40010
Cable structure
Inner conductor diameter mm 7 x 0,2 7 x 0,2 7 x 0,1 7 x 0,1 7 x 0,1 7 x 0,1
Steel/copper, bare Steel/copper, bare Steel/copper, silvered Steel/copper, silvered Steel/copper, silvered Steel/copper, silvered
Insulation mm 1,52 PE 1,52 PE 0,86 PTFE 1,6 PTFE 2,6 PTFE 1,6 PTFE
Outer conductor Braid Braid Braid Braid Braid Braid
Tinned copper Tinned copper Silvered copper Silvered copper Silvered copper Silvered copper
- - - - - -
Outer sheath PVC PVC FEP FEP FEP PFA
Min. bending radius approx. mm 15 15 10 15 25 15
Temperature range C -35 to +80 -35 to +80 -55 to +200 -55 to +200 -55 to +200 -55 to +260
Copper weight kg/km 7,0 7,0 7,0 8,0 11,0 9,0
Outer approx. mm 2,8 2,6 1,8 2,5 3,7 2,6
Weight approx. kg / km 11 11 8 16 28 17
Electrical characteristics
Impedance (Ohm) 50 2 50 2 50 2 75 3 95 5 75 3
M
Frequency range
f (max.) GHz 1 1 3 3 3 3
Propagation velocity v/c 0,7 0,7 0,7 0,7 0,7 0,7
Attenuation at 20C
(db/100m)
100 MHz 30 30 43 28 20 28
200 MHz 45 45 62 41 33 41
500 MHz 73 73 102 69 - 69
800 MHz 93 93 134 92 - 92
1000 MHz - - - - - -
1350 MHz - - - - - -
1750 MHz - - - - - -
CapacitancepF/m 101 101 93 63 50 64
Rel. velocity of propagation % 70 70 70 70 70 70
Insulation resistance
MOhm x kmmin. 10
5
10
5
10
5
10
5
10
5
10
5
Loop resistance
max. (Ohm/km) 360 360 860 840 840 840
Nominal peak voltagekVs 1 1 1 1 2 1
Dielectric strength
50 HzkVeff 2 2 2 2 2 2
Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
The colour at FEP and PFA outer sheath is brown or white as per production outlet.
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility
Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions. The varied
mechanical, thermal and electronic properties of Coaxial cables mean that they can be used up into the GHz levels, as per cable type.
339
Coaxial Cables
RG-Coaxial Cables
Cable structure
Inner conductor diameter mm 7 x 0,8 7 x 0,8 1 x 2,7 1 x 4,95 1 x 0,9 7 x 0,2
Copper, bare Silvered copper Copper, bare Copper, bare Silvered copper Steel/copper, silvered
Insulation mm 7,24 PE 7,24 PE 9,4 PE 17,3 PE 2,95 PE 1,52 PTFE
Outer conductor Braid 2 braids 2 braids Braid 2 braids Braid
Copper, bare 2x silvered copper Copper, bare Copper, bare 2x silvered copper Silvered copper
- - - - - -
Outer sheath PVC PVC PVC PVC PVC PTFE/ alt. FEP
Min. bending radius approx. mm 50 50 70 110 25 15
Temperature range C -35 to +80 -35 to +80 -35 to +80 -35 to +80 -35 to +80 -55 to +200
Copper weight kg/km 85,0 120,0 187,0 348,0 44,0 9,0
Outer approx. mm 10,3 10,8 13,84 22,1 5,2 2,5
Weight approx. kg / km 159 198 300 710 60 15
Electrical characteristics
Impedance (Ohm) 50 2 50 2 50 2 50 2 50 2 50 2
Frequency range
f (max.) GHz 3 11 3 3 3 3
Propagation velocity v/c 0,7 0,7 0,66 0,66 0,7 0,7
Attenuation at 20C
(db/100m)
100 MHz 7 7 4,8 2,9 17 28
200 MHz 10,2 10,2 7,1 4,5 23 40
500 MHz 17 17 12,3 8,1 38 68
800 MHz 23 23 16,8 11,2 50 90
1000 MHz - - - - - -
1350 MHz - - - - - -
1750 MHz - - - - - -
CapacitancepF/m 101 101 101 101 101 95
Rel. velocity of propagation % 100 67 100 100 67 70
Insulation resistance
MOhm x kmmin. 10
5
10
5
10
5
10
5
10
5
10
5
Loop resistance
max. (Ohm/km) 10 10 5 2 36 310
Nominal peak voltagekVs 5 5 7 11 2 1
Dielectric strength
50 HzkVeff 10 10 10 15 5 2
Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
The colour outer sheath at PTFE is brown or transparent as per production outlet.
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility
Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions. The varied
mechanical, thermal and electronic properties of Coaxial cables mean that they can be used up into the GHz levels, as per cable type.
340
Coaxial Cables
Cable structure
Inner conductor diameter mm 7 x 0,4 19 x 0,2 1 x 0,6 1 x 0,6 1 x 0,6 7 x 0,8 7 x 0,8
Tinned copper Tinned copper Steel/copper, bare Steel/copper, bare Steel/copper, bare Copper, bare Silvered copper
Insulation mm 7,3 PE 2,95 PE 3,7 PE 3,7 PE, hollow 3,7 PE, hollow 7,24 PE 7,24 PE
Outer conductor Braid Braid Braid Braid 2 braids Braid 2 braids
Copper, bare Tinned copper Copper, bare Copper, bare Copper, bare Copper, bare 2x silvered copper
- - - - Tinned copper - -
Outer sheath HM2 HM2 HM2 HM2 HM2 HM2 HM2
Min. bending radius approx. mm 50 25 30 30 30 50 50
Temperature range C -35 to +80 -35 to +80 -35 to +80 -35 to +80 -50 to +70 -35 to +80 -35 to +80
Copper weight kg/km 58,0 29,0 28,0 28,0 48,0 85,0 120,0
Outer approx. mm 10,3 5,4 6,4 6,4 6,9 10,3 10,8
Weight approx. kg / km 144 38 57 54 64 155 203
Electrical characteristics
Impedance (Ohm) 75 3 50 2 75 3 93 5 93 3 50 2 50 2
M
Frequency range
f (max.) GHz 3 3 3 3 3 3 11
Propagation velocity v/c 0,7 0,7 0,7 0,8 0,8 0,7 0,7
Attenuation at 20C
(db/100m)
3 MHz 1,3 2,9 2 2 2 1,2 1,2
10 MHz 2,4 5,3 3,8 3,7 3,7 2,3 2,3
100 MHz 7,8 17 12,2 12 12,5 7,5 7,5
200 MHz 11,3 24,4 17,6 17,3 17,3 10,9 10,9
500 MHz 18,7 39,2 27,2 24,7 24,7 17,2 17,2
800 MHz 23,4 47,8 35,2 34,6 34,6 22,6 22,6
CapacitancepF/m 68 0 68 42,5 42,5 101 101
Rel. velocity of propagation % 67 67 67 43 43 101 101
Insulation resistance
MOhm x kmmin. 10
5
10
5
10
5
10
5
10
5
10
5
10
5
Loop resistance
max. (Ohm/km) 23 53 171 155 136 10 10
Nominal peak voltagekVs 5 2 2 1 1 5 5
Dielectric strength
50 HzkVeff. 10 5 7 3 3 10 10
Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
H-outer sheath = halogen-free material (HM2)
RG-Coaxial types are in accordance with US-Military specifications MIL-C-17.
RG/U: R=Radio, G=Guide, U=Utility
FRNC = Flame Retardant Non-Corrosive
Application
Coaxial cables are used in high frequency transmission, especially for transmitters and receivers, computers, radio and TV transmissions where no
flame propagation under behaviour in fire is permitted. The varied mechanical, thermal and electronic properties of Coaxial cables mean that they can
be used up into the GHz levels, as per cable type.
341
Coaxial Cables
Cable structure
Inner conductor diameter mm 0,7 1,1 1,1 1,8 1,1 2,2 3,3 4,9
Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare
Insulation mm 4,4 PE 7,3 PE 7,3 PE 11,5 PE 7,3 PE 8,8 PE, hollow 13,5 PE, hollow 19,4 PE, hollow
Outer conductor Polyester foil Polyester foil Polyester foil Copper tape Copper tube, Copper tube, Copper tube, Copper tube,
coated with coated with coated with welded welded welded welded
aluminium on both aluminium on both aluminium on both
sides sides sides
Braid Braid Braid Braid - - - -
- - - - - - - -
Outer sheath PVC PE PE PE PE PE PE PE
Sheath colour white black black black black black black black
Outer approx. mm 6,6 10,5 2,8 15,0 11,0 12,5 17,0 24,4
Min. bending radius approx. mm 35 100 150 150 160 200 300 400
Strain/suspending wire N - - 5500 - - - - -
Weight approx. kg / km 44 98 177 218 142 183 347 500
Electrical characteristics
Impedance (Ohm) 75 3 75 3 75 3 75 3 75 2 75 2 75 1 75 1
CapacitancepF/m 67 67 67 67 65 51 51 50
Propagation velocity v/c 0,7 0,7 0,7 0,7 0,7 0,88 0,88 0,89
Attenuation at 20C
(db/100m)
100 MHz 9 5,2 5,2 3,5 5,4 2,8 1,9 1,3
200 MHz 12 7,3 7,3 5,2 7,9 4 2,7 1,9
500 MHz 21,2 12,6 12,6 9 12,9 6,6 4,4 3,1
800 MHz 27,5 16,8 16,8 12 17,3 8,4 5,7 4,1
950 MHz 30,5 18,8 18,8 13 18,9 9,3 6,3 4,4
1350 MHz 37 23 23 - - - - -
1750 MHz 43 27,7 27,7 - - - - -
2050 MHz 47,5 30,2 30,2 - - - - -
Structural return loss min. (dB) between
30 and 300 MHz 30 32 32 30 26 26 28 28
300 and 600 MHz 30 32 32 30 23 23 25 25
600 and 960 MHz 25 30 30 28 21 21 23 23
960 and 1750 MHz 23 27 27 25 - - - -
DC resistance at 20C
Inner conductor max.Ohm/km 47 18,5 18,5 7,3 22 5,6 2,5 1
Outer conductor max.Ohm/km 23 11 11 6,5 3,1 3 2 1
Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
BK-underground: broadband cable in accordance with FTZ 15 TV 11 (post cable)
AL=Aluminium, ALPR=Polyesterfoil coated with Aluminium on both sides
BK-cable=broadband communication cable, Cu=Copper, CuR=Cu-tube welded, CuW=Copperweld, F=Foil, G=Braid, PE=Polyethylene,
PEH=Polyethylene air-space insulation, PVC=Polyvinylchloride
342
Coaxial Cables
Cable structure
Inner conductor diameter mm 1,1 Tinned copper 1,6 Copper, bare 0,8 Copper, bare 0,65 Copper, bare 0,6 Copper, bare
Insulation mm 5 Cell PE 7,2 Cell PE 3,5 Cell PE 3 Cell PE 3 Cell PE
Core colours - - - - -
Outer conductor Polyester foil coated with Polyester foil coated with Polyester foil coated with Polyester foil coated with Polyester foil coated with
aluminium on both sides aluminium on both sides aluminium on both sides aluminium on both sides aluminium on both sides
Braid Braid Braid Braid Braid
- - - - -
Outer sheath PVC PE PVC PVC PVC
Sheath colour white black white white white
Outer approx. mm 6,8 10,1 5,4 x 10,8 8,6 x 4,3 20,0 x 4,3
Min. bending radius approx. mm 50 60 40 35 80
Weight approx. kg / km 49 81 62 40 82
Electrical characteristics
Impedance (Ohm) 75 3 75 3 75 3 75 3 75 3
M
CapacitancepF/m 55 55 55 55 55
Propagation velocity v/c 0,8 0,82 0,82 0,8 0,8
Attenuation at 20C
(db/100m)
100 MHz 5 3,7 8 8,9 8,9
200 MHz 7,3 5,1 11,5 13,5 13,5
500 MHz 13 9 18,5 22 22
800 MHz 17,2 11,8 23,5 28 28
950 MHz 19,5 13,6 25,5 31,5 31,5
1350 MHz 23,5 16,8 31 37 37
1750 MHz 27,6 19,7 35,5 42,3 42,3
2050 MHz 30 22 39,5 45,9 45,9
2150 MHz 31 22,5 43 50,4 50,4
Structural return loss min. (dB) between
30 and 300 MHz 28 31 27 20 20
300 and 600 MHz 28 30 25 17 18
600 and 960 MHz 26 30 20 17 15
960 and 2050 MHz 24 28 20 - -
DC resistance at 20C
Inner conductor max.Ohm/km 18 9 36 110 52
Outer conductor max.Ohm/km 20 12 28 22 26
Max. nominal voltage (V) - - - - -
Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
AL=Aluminium, ALPR=Polyesterfoil coated with Aluminium on both sides
Cu=Copper, CuW=Copperweld, F=Foil, G=Braid, PE=Polyethylene, PEH=Polyethylene air-space insulation, PVC=Polyvinylchloride, vz=tinned
343
Coaxial Cables
Cable structure
Inner conductor diameter mm 1 Copper with skin 1 Copper with skin 1 Copper with skin
Insulation mm 4,6 Cell polyethylene with skin and PIB 4,6 Cell polyethylene with skin and PIB 4,6 Cell polyethylene with skin and
coating coating PIB coating
Outer conductor Polyester foil coated with aluminium on Polyester foil coated with aluminium on Polyester foil coated with aluminium
both sides both sides on both sides
Outer sheath PVC PE FRNC
Sheath colour white black grey
Outer approx. mm 6,6 6,6 6,6
Approv. bending radius approx. mm 45 45 45
Weight approx. kg / km 40 40 40
Electrical characteristics
Impedance (Ohm) 75 1 75 1 75 1
CapacitancepF/m 55 55 55
Propagation velocity v/c 0,8 0,85 0,85
Attenuation at 20C
(db/100m)
100 MHz 5,8 5,8 5,8
200 MHz 7,8 7,8 7,8
450 MHz 12,5 12,5 12,5
600 MHz 14,7 14,7 14,7
800 MHz 17,2 17,2 17,2
1000 MHz 19,1 19,1 19,1
1750 MHz 26,2 26,2 26,2
2050 MHz 28,5 28,5 28,5
2400 MHz 31,3 31,3 31,3
Structural return loss min. (dB) between
30 and 300 MHz 30 30 30
300 and 600 MHz 32 32 32
600 and 960 MHz 31 31 31
960 and 1750 MHz 26 26 26
1750 and 2400 MHz 30 30 30
DC resistance at 20C
Inner conductor max.Ohm/km 18 18 18
Outer conductor max.Ohm/km 20 20 20
Max. nominal voltage (V) - - -
Note
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
FRNC=Flame Retardant Non Corrosive, PEE= Cell-Polyethylene, PIB= Polyisobutylene, ALPR=Polyesterfoil coated with Aluminium on both sides
F=Foil, G=Braid, GH=Braid-covering ca. 88%
Application
Copper inner-conductor 1,02 with skin-effect
Protection against humidity and corrosion / Solid compound of dielectric. No change of position during installation in narrow bending radius.
Dielectric 4,6 mm : - special PE-compound, foaming by GAS-INJEKTION
Important improvement of propagation velocity values / Very high transmission speed of individual signals (presumption for Multimedia) /
Improvement for the resistance to ageing / Reduction of attenuation-loss by approx. 2dB
The over surface of dielectric consists too a skin-coating (smooth over surface)
Protection against humidity and other chemical influences / Minimum impedance tolerance 2 Ohm / This coaxial cable is crimpable / Installation
in narrow bending radius, no kinking risk / The transmission-loss of signals are hardly measurable to the advance in years / Additionally to the
skin-effect, the dielectric contains a gel-coating (special PIB-cpmpound) / We therefore offer a 15 years guarantee for attenuation-loss by
installation at 20C room-temperature
Screening
a) AL/PR-foil, polyesterfoil coated with aluminium on both sides or b) Copper braiding of tinned wires, screening efficiency >90 dB
344
Coaxial Cables
Cable structure
Inner conductor diameter mm 0,6 0,75 0,8 1,1 1,63 1,1 1,1 1,6
Copper, bare Tinned copper Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare
Insulation mm 3 Polyethylene, 4,5 Polyethylene, 3,5 Polyethylene, 4,8 Polyethylene, 7,1 Polyethylene, 4,8 Cell PE, 4,8 Cell PE, 7,1 Polyethylene,
foamed foamed foamed foamed foamed foamed foamed foamed
Outer conductor ALPR-FG ALPR-FG ALPR-FG ALPR-FG ALPR-FG ALPR-FG ALPR-FG ALPR-FG
- - - - - - - -
1st Screen - ALPR foil foil foil foil foil foil foil foil
2nd Screen - Cu-Braid Braid Braid Braid Braid Braid Braid Braid Braid
Outer sheath PVC PVC PVC PVC PE FRNC FRNC FRNC
Sheath colour white white white white black white black white
Outer approx. mm 4,3 6,6 5,0 6,9 10,3 6,8 6,8 10,0
M
Min. bending radius approx. mm 43 35 50 45 60 48 48 60
Weight approx. kg / km 20 40 32 47 110 47 47 110
Electrical characteristics
Impedance (Ohm) 75 3 75 3 75 3 75 2 75 2 75 2 75 2 75 2
CapacitancepF/m 55 67 53 55 55 53 55 53
Propagation velocity v/c 0,8 0,66 0,8 0,8 0,85 0,8 0,8 0,8
Attenuation at 20C
(db/100m)
100 MHz 8,1 7,1 6,3 4,9 3 4,7 4,9 3,8
200 MHz 13,3 10,4 11,5 7,7 6,1 7 7,2 5,5
450 MHz 20,9 16,8 17,1 11,6 9 11,5 11,6 8,6
800 MHz - 25 - - - 17 - 12,1
1000 MHz 31,5 27,4 26,5 18,9 14,3 18,1 18,9 13,2
1750 MHz 42,2 37,4 36,4 26,6 20,1 25 26,6 17,5
2050 MHz 45,8 40,5 39,7 28,2 22,5 27,3 28,2 19
2250 MHz 49,9 44,3 43,1 29,5 24 28 29,5 19,9
2400 MHz 55,5 45 - 31,9 - 29,3 31,9 22,5
Structural return loss min. (dB) between
30 and 300 MHz 20 20 35 25 40 25 40 25
300 and 600 MHz 18 18 35 18 35 18 40 18
600 and 960 MHz 16 18 30 17 35 17 35 17
960 and 1750 MHz - - 30 15 30 15 30 15
DC resistance at 20C
Inner conductor max.Ohm/km 52 110 36 18 9 18 18 9
Outer conductor max.Ohm/km 29 22 28 14 21 14 14 21
Max. nominal voltage (V) - - - - - - - -
Copper weight kg/km 12,5 9,0 9,0 25,0 32,0 25,0 25,0 50,5
345
Coaxial Cables
Application
RGB cables are suitable for the transmission of both analogue and digital video signals.
They are used particularly as connecting cables for data systems, engineering applications (CAD, high-definition graphics) and in television studios.
The three main signals (red, green, blue) are transmitted separately. Depending on the application, it is possible to supply the base cable with further
coaxial cables or with symmetrical signal cores for the intensity and horizontal or vertical synchronisation.
RGB-COAX-CY ... 0,37/1,5 RGB-COAX-(St)Y ... 0,6/3,7
Part no. No. RGB-Coax Outer Cop. Weight Part no. No. RGB-Coax Outer Cop. Weight
n x mm approx. weight approx. n x mm approx. weight approx.
mm kg / km kg / km mm kg / km kg / km
40145 3 x 0,37/1,5 7,2 23,0 59,0 40148 3 x 0,6/3,7 16,0 66,0 278,0
40147 3 x 0,37/1,5 + 3 x 0,25 8,2 60,5 89,0 40149 5 x 0,6/3,7 19,0 102,0 397,0
40146 5 x 0,37/1,5 9,0 36,0 89,0
346
NFPA 79 EDITION 2012
Challenges and solutions
THE COMPLETE ORIGINAL WORDING
349
CABLES ACCORDING TO INTERNATIONAL APPROVALS
3
in
E
VD iel 029
ng
x
xe
ex
VD
g e 0 /U
ed
xi
- fi
- fl
./
le
fix
E
lta U
ed
no
H A ed / VD
-f
C)
C)
vo e
s-
d
al ag
us
CS REG
(
s
re ree
in volt
R/ /sh
di
di
re core
se
re
re
t
ut tan
n
ra
a
tu
tu
Dr or u
f
E
r
Co hai
n-
om l
Pa 9
is
ra
ra
g
N ina
A
d
7
ge
s
in
in
en
pe
pe
re
c
do
A
ge
om
nd
nd
ag
lo
lo
V-
m
L/
FP
Ha
Be
Be
Sc
Te
Te
O
U
N
PVC control lines UL/CSA
TRAYCONTROL 500
-5 to +90 -40 to +90 600 4x 4x X X 359
JZ 604 TC TRAY CABLE -5 to +75 -25 to +75 600 7.5x 7.5x X X X X 364
FROR CEI 20-22 II -5 to +70 -35 to +70 300/500 10x 10x (X) 371
JZ 604-FCY TC TRAY CABLE -5 to +75 -25 to +75 600 10x 10x X X X X X 380
JZ 604-YCY TC TRAY CABLE -5 to +75 -25 to +75 600 10x 10x X X X X X 381
MEGAFLEX 600
-30 to +80 -40 to +80 600 10x 4x X X X X 396
MEGAFLEX 500-C
-30 to +80 -40 to +80 600 10x 4x X X X X X 398
Command Cable UL (LiYY) -10 to +80 -20 to +80 300 15x 7.5x X X 403
Command Cable UL (LiYY) -10 to +105 -20 to +105 600 15x 7.5x X X 404
Command Cable UL (LiYY-TP)) -10 to +80 -20 to +80 300 15x 7.5x X X 407
Command Cable UL (LiYCY) -10 to +80 -20 to +80 300 15x 7.5x X X X 413
Command Cable UL (LiYCY) -10 to +105 -20 to +105 600 15x 7.5x X X X 415
TRAYCONTROL 300-C
-25 to +105 300 6x 6x X X X X 416
350
CABLES ACCORDING TO INTERNATIONAL APPROVALS
3
in
E
VD ield 029
ng
x
xe
ex
VD
g e 0 /U
d
xi
- fi
- fl
./
le
fix
E
lta U
d
no
H A d / VD
-f
e
C)
C)
vo e
-
al ag
us
us
CS REG
(
en res
e
in volt
R/ /sh
di
di
ag use
re
re
t
e
an
V- -fr
lo in
ra
ra
o
tu
tu
E
Sc d c
O sist
a
om l
Pa 79
r
ra
ra
n
g
g
N ina
A
e
ch
o
ge
in
in
pe
pe
re
do
re
A
ge
om
nd
nd
lo
re
m
L/
FP
ut
Ha
Co
Be
Be
Dr
Te
Te
N
Data lines UL/CSA
Command Cable UL (LiYCY-TP) -10 to +80 -20 to +80 300 15x 7.5x X X X 418
TRAYCONTROL 300-C TP
-25 to +105 300 6x 6x X X X X 420
MULTIFLEX 512 PUR UL/CSA -30 to +80 -40 to +80 600 5x 3x X X X X X 431
MULTISPEED 500-PUR UL/CSA -30 to +80 -40 to +80 600 7.5x 4x X X X X X 433
MULTISPEED 500-C-PUR UL/CSA -30 to +80 -40 to +80 600 7.5x 4x X X X X X X 539
SUPERTRONIC -310-PVC
-5 to +80 -40 to +80 300 5x 3x X X 445
N
SUPERTRONIC-310-C-PVC -5 to +80 -40 to +80 300 7.5x 4x X X X 446
TOPFLEX 1000 VFD -25 to +90 -25 to +90 600 15x 7.5x X X X X X 460
TOPFLEX MOTOR EMV 1/1 -30 to +80 -40 to +80 1000 20x 10x X X X X X 462
TOPFLEX MOTOR EMV 3/3 -30 to +80 -40 to +80 1000 20x 10x X X X X X 463
TOPSERV PVC 108, 112, 119 -0 to +60 -20 to +80 1000 15x 5x X X 465
TOPSERV PUR 109, 113, 121 -30 to +80 -40 to +80 1000 7.5x 4x X X X X X 468
TOPSERV 600 VFD -25 to +90 -25 to +90 600 7.5x 5x X X X X X X 472
351
CABLES ACCORDING TO INTERNATIONAL APPROVALS
3
in
E
VD ield 029
ng
x
xe
ex
VD
g e 0 /U
d
xi
- fi
- fl
./
le
ix
E
lta U
ed
no
H A ed / VD
-f
-f
C)
C)
vo e
al ag
us
CS REG
(
s
re ree
in volt
R/ /sh
di
di
re core
se
re
re
t
an
n
ra
ra
tu
tu
Dr or u
f
E
Co hai
n-
O sist
om l
Pa 9
ra
ra
g
N ina
A
d
7
ge
in
in
en
pe
pe
re
c
do
A
ge
om
nd
nd
ag
lo
lo
V-
m
L/
FP
ut
Ha
Be
Be
Sc
Te
Te
N
Motor, servo, feedback cables UL/CSA
TOPSERV 650 VFD -25 to +105 -25 to +105 600 7.5x 5x X X X X X X 473
Single-core UL/CSA
HELUTHERM 145
-35 to +105 -55 to +105 300 12.5x 4x X X X X X 495
352
SELECTION TABLE - DRAG CHAIN CABLES
ng
in
xi
g
/s 2
ce
fle
in
/
an
ex
ge U
(m
-
es ist
lta 0 /
- fl
us
)
-c t d
vo U
/s
di
io
)
C)
g ge
en
(m
ra
at
or
(
tin lta
er
m
re
in
s
25
e
el
ra vo
ee
le
ov
nd
tu
s
c
yc
)
al
to
sp
ac
pe l
ra
ia
m
O ina
be
ov
r
.c
up
te
er
pe
.
ge
.
ax
ax
ou
pr
ax
ax
m
om
.
at
in
m
=
Ap
M
M
0
Pa
M
M
M
M
(D
(1
Te
N
PVC drag chain cables UL/CSA
SUPERTRONIC-310-PVC 5 5xD 2 10 9 Mio PVC/PVC 300V -5 to +80 UL/CSA 445
SUPERTRONIC -310-C-PVC
5 7.5 x D 2 10 9 Mio PVC/CU/PVC 300V -5 to +80 UL/CSA 446
MULTISPEED 500-PVC UL/CSA 100 7.5 x D 5 50 9 Mio PP/PVC 600V -5 to +80 UL/CSA 425
MULTISPEED 500-C-PVC UL/CSA 100 7.5 x D 5 50 9 Mio PP/CU/PVC 600V -5 to +80 UL/CSA 429
JZ-HF-FCY 10 10 x D 2 10 9 Mio PVC/CU/PVC 1000V -5 to +80 UL/CSA 426
JZ-602 RC 10 7.5 x D 2 10 9 Mio PVC/PVC 600V -5 to +90 UL/CSA 423
JZ-602 RC-CY 10 10 x D 2 10 9 Mio PVC/CU/PVC 600V -5 to +90 UL/CSA 427
MULTIFLEX 600 10 7.5 x D 2 10 9 Mio PVC/PVC 600V -5 to +90 UL/CSA 424
MULTIFLEX 600-C 10 10 x D 2 10 9 Mio PVC/CU/PVC 600V -5 to +90 UL/CSA 428
PUR & TPE drag chain cables UL/CSA
SUPERTRONIC-330 PUR 15 5xD 4 10 11 Mio PP/PUR 300V -30 to +80 UL/CSA 447
SUPERTRONIC-330 C-PUR 15 7.5 x D 4 10 11 Mio PP/CU/PUR 300V -30 to +80 UL/CSA 449
SUPER-PAAR-TRONIC 340-C-PUR 30 10 x D 4 50 11 Mio PP/CU/PUR 300V -30 to +80 UL/CSA 451
JZ-602 RC-PUR 15 7.5 x D 3 10 9 Mio PVC/PUR 600V -5 to +80 UL/CSA 430
JZ 602 RC-C-PUR 15 10 x D 3 10 9 Mio PVC/CU/PUR 600V -5 to +80 UL/CSA 436
PUR-JZ-HF-FCP 15 10 x D 3 10 9 Mio PVC/CU/PUR 1000V -5 to +80 UL/CSA 435
MULTIFLEX 512-PUR UL/CSA 100 5xD 4 10 11 Mio PP/PUR 600V -30 to +80 UL/CSA 431
MULTIFLEX 512-C-PUR UL/CSA 100 7.5 x D 4 10 11 Mio PP/CU/PUR 600V -30 to +80 UL/CSA 437
MULTISPEED -TRONIC-PUR
450 7.5 x D 5 50 11 Mio PP/PUR 300V -30 to +80 UL/CSA 448
MULTISPEED-TRONIC-C-PUR 450 7.5 x D 5 50 11 Mio PP/CU/PUR 300V -30 to +80 UL/CSA 450
MULTISPEED 500-PUR UL/CSA 450 7.5 x D 5 50 11 Mio PP/PUR 600V -30 to +80 UL/CSA 433
MULTISPEED 500-C-PUR UL/CSA
450 7.5 x D 5 50 11 Mio PP/CU/PUR 600V -30 to +80 UL/CSA 439 N
MULTISPEED 500-TPE UL/CSA 450 5xD 5 50 11 Mio PP/TPE 600V -30 to +80 UL/CSA 441
MULTISPEED 500-C-TPE UL/CSA 450 5xD 5 50 11 Mio PP/CU/TPE 600V -30 to +80 UL/CSA 443
Single-cores for drag chain cables UL/CSA
SINGLE 602-RC-J/-O 5 7.5 x D 2 10 9 Mio PVC/PVC 600V -5 to +90 UL/CSA 501
SINGLE 602-RC-CY-J/-O 5 7.5 x D 2 10 9 Mio PVC/CU/PVC 600V -5 to +90 UL/CSA 502
MULTISPEED 600-PUR-J/-O 450 5xD 5 50 11 Mio Poly/PUR 1000V -30 to +80 UL/CSA 504
MULTISPEED 600-C-PUR-J/-O 450 5xD 5 50 11 Mio Poly/CU/TPE 1000V -30 to +80 UL/CSA 505
TOPFLEX 301
5 7.5 x D 2 10 10 Mio PVC/PUR 1000V -15 to +80 UL/CSA 506
TOPFLEX 301 C 5 7.5 x D 2 10 10 Mio PVC/CU/PUR 1000V -15 to +80 UL/CSA 506
TOPFLEX 304 5 5xD 2 10 9 Mio PVC/PVC 1000V -5 to +80 UL/CSA 503
TOPFLEX 304 C 5 5xD 2 10 9 Mio PVC/CU/PVC 1000V -5 to +80 UL/CSA 503
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).
353
SELECTION TABLE - DRAG CHAIN CABLES
ng
in
xi
g
/s 2
ce
fle
in
/
an
ex
ge U
(m
-
es ist
lta 0 /
- fl
us
)
-c t d
vo U
/s
di
io
)
C)
g ge
en
(m
ra
at
or
(
tin lta
er
m
re
in
s
25
e
el
ra vo
ee
le
ov
nd
tu
s
c
yc
)
al
to
sp
ac
pe l
ra
ia
m
O ina
be
ov
r
.c
up
te
er
pe
.
ge
.
ax
ax
ou
pr
ax
ax
m
om
.
at
in
m
=
Ap
M
M
0
Pa
M
M
M
M
(D
(1
Te
N
Motor cables & servo cables for drag chain cables UL/CSA
TOPSERV 109 PUR 30 7.5 x D 4 10 11 Mio PP/CU/PUR 1000V -30 to +80 UL/CSA 468
TOPSERV 113 PUR
30 7.5 x D 4 10 11 Mio PP/CU/PUR 1000V -30 to +80 UL/CSA 468
TOPSERV 121 PUR 30 7.5 x D 4 10 11 Mio PP/CU/PUR 1000V -30 to +80 UL/CSA 468
TOPSERV 600 VFD 10 7.5 x D 2 10 9 Mio PVC/CU/TPE 600V -25 to +90 UL/CSA 472
TOPSERV 650 VFD
10 7.5 x D 2 10 9 Mio PVC/CU/TPE 600V -25 to +90 UL/CSA 473
Feedback cables for drag chain cables UL/CSA
TOPGEBER 512 PUR 30 10 x D 4 50 11 Mio PP/CU/PUR 30V -30 to +80 UL/CSA 470
TOPSERV HYBRID PVC 5 7.5 x D 0,5 2 5 Mio PP/PVC 1000V -30 to +80 UL/CSA 474
TOPSERV HYBRID PUR 50 7.5 x D 5 30 5 Mio PP/PUR 1000V -30 to +80 UL/CSA 474
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).
354
UL/CSA CONTROL CABLES
Cables according to international Approvals / PVC-Control Cables UL/CSA
JZ-602 two approval control cable, 90C, 600 V, oil resistant, meter
marking
Application
UL-approved and CSA certified flexible control cable rated at 600 V. Used in machine tools, control systems, connection between control panels and
machines, assembly lines and other industrial equipment. Suitable for installation in dry, moist or wet environment and moderate flexing applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
83090 2 x 0,5 20 5,6 9,6 49,0 83104 9 G 1,5 16 11,5 129,7 244,0
83091 3 G 0,5 20 5,9 14,0 58,0 83075 12 G 1,5 16 12,6 173,0 319,0
83092 4 G 0,5 20 6,4 19,0 69,0 83076 18 G 1,5 16 15,8 260,0 451,0
83093 5 G 0,5 20 6,9 24,0 84,0 83077 25 G 1,5 16 18,3 360,0 625,0
83094 7 G 0,5 20 7,5 34,0 123,0 83078 34 G 1,5 16 21,4 490,0 840,0
83100 8 G 0,5 20 8,3 38,4 140,0 83079 41 G 1,5 16 23,3 590,0 1032,0
83101 9 G 0,5 20 8,9 43,2 177,0 83060 2 x 2,5 14 7,8 48,0 115,0
83095 12 G 0,5 20 9,8 58,0 192,0 83061 3 G 2,5 14 8,5 72,0 143,0
83096 18 G 0,5 20 12,0 86,0 256,0 83062 4 G 2,5 14 9,3 96,0 185,0
83097 25 G 0,5 20 14,3 120,0 358,0 83063 5 G 2,5 14 10,4 120,0 221,0
83098 34 G 0,5 20 16,5 163,0 487,0 83064 7 G 2,5 14 11,5 168,0 293,0
83099 41 G 0,5 20 17,9 197,0 580,0 83065 9 G 2,5 14 13,9 216,0 429,0
83080 2x1 18 6,3 19,2 53,0 83066 12 G 2,5 14 15,2 288,0 563,0
83081 3G1 18 6,6 27,0 61,0 83067 18 G 2,5 14 18,7 432,0 854,0
83082 4G1 18 7,2 38,4 74,0 83068 19 G 2,5 14 18,7 456,0 914,0
83565 3x1 18 6,6 27,0 61,0 83069 25 G 2,5 14 22,2 600,0 1188,0
83083 5G1 18 7,9 48,0 90,0 83051 3G4 12 9,7 115,0 232,0
83084 7G1 18 8,7 67,0 130,0 83052 4G4 12 10,6 154,0 298,0
83102 8G1 18 9,5 76,8 144,0 83053 5G4 12 11,8 192,0 358,0
83103 9G1 18 10,4 86,4 180,0 83054 7G4 12 13,1 269,0 460,0
83085 12 G 1 18 11,2 115,2 198,0 83041 3G6 10 11,3 173,0 360,0
83086 18 G 1 18 14,1 173,0 274,0 83042 4G6 10 12,5 231,0 402,0
83087 25 G 1 18 16,8 240,0 384,0 83043 5G6 10 13,9 288,0 484,0
83088 34 G 1 18 19,5 326,0 494,0 83044 7G6 10 15,4 403,0 630,0
83089 41 G 1 18 21,2 394,0 508,0 83031 3 G 10 8 14,7 288,0 535,0
83070 2 x 1,5 16 6,8 28,8 73,0 83032 4 G 10 8 16,3 384,0 653,0
83071 3 G 1,5 16 7,2 44,0 94,0 83033 5 G 10 8 18,3 480,0 786,0
83072 4 G 1,5 16 7,9 58,0 117,0 83034 7 G 10 8 20,2 672,0 1100,0
83073 5 G 1,5 16 8,7 72,0 140,0
83074 7 G 1,5 16 9,7 101,0 186,0
Continuation
356
Cables according to international Approvals / PVC-Control Cables UL/CSA
JZ-602 two approval control cable, 90C, 600 V, oil resistant, meter
marking
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
83020 2 x 16 6 18,8 307,0 640,0 83007 3 G 70 2/0 36,8 2016,0 3307,0
83021 3 G 16 6 20,2 461,0 810,0 83008 4 G 70 2/0 40,9 2688,0 4254,0
83022 4 G 16 6 22,3 615,0 1045,0 83009 5 G 70 2/0 45,6 3360,0 5661,0
83023 5 G 16 6 24,9 768,0 1260,0 83010 3 G 95 3/0 40,9 2736,0 4867,0
83024 7 G 16 6 27,5 1075,0 1760,0 83015 4 G 95 3/0 45,6 3648,0 5762,0
83011 3 G 25 4 24,0 720,0 1180,0 83016 5 G 95 3/0 50,7 4560,0 7208,0
83012 4 G 25 4 26,9 960,0 1507,0 83017 3 G 120 4/0 48,1 3456,0 5580,0
83013 5 G 25 4 31,9 1200,0 1858,0 83018 4 G 120 4/0 53,3 4608,0 7280,0
83014 7 G 25 4 33,0 1680,0 2830,0 83019 5 G 120 4/0 58,9 5760,0 8692,0
83001 3 G 35 2 26,2 1008,0 1590,0
83002 4 G 35 2 29,7 1344,0 2123,0
83003 5 G 35 2 33,0 1680,0 2612,0
83004 3 G 50 1 31,9 1440,0 2652,0
83005 4 G 50 1 35,6 1920,0 3058,0
83006 5 G 50 1 39,7 2400,0 4093,0
357
Cables according to international Approvals / PVC-Control Cables UL/CSA
Application
UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control
systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for mechanical stresses with free movements in dry,
moist and wet rooms but not for open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
83704 2 x 0,5 20 5,8 9,6 52,0 83679 34 G 1 18 20,3 326,0 742,0
83650 3 G 0,5 20 6,1 14,0 63,0 83680 41 G 1 18 22,4 394,0 885,0
83651 4 G 0,5 20 6,7 19,0 69,0 83681 50 G 1 18 24,3 480,0 1071,0
83652 5 G 0,5 20 7,3 24,0 87,0 83682 61 G 1 18 26,8 586,0 1265,0
83653 7 G 0,5 20 8,8 34,0 119,0 83707 2 x 1,5 16 7,4 28,8 91,0
83654 12 G 0,5 20 11,1 58,0 198,0 83683 3 G 1,5 16 8,0 43,0 110,0
83655 18 G 0,5 20 12,9 86,0 266,0 83684 4 G 1,5 16 8,7 58,0 141,0
83656 25 G 0,5 20 16,0 120,0 380,0 83685 5 G 1,5 16 9,8 72,0 167,0
83657 34 G 0,5 20 17,7 163,0 508,0 83686 7 G 1,5 16 11,9 101,0 225,0
83658 41 G 0,5 20 19,5 197,0 594,0 83687 12 G 1,5 16 14,5 173,0 361,0
83659 50 G 0,5 20 21,3 240,0 715,0 83688 18 G 1,5 16 17,4 259,0 518,0
83660 61 G 0,5 20 23,8 293,0 840,0 83689 25 G 1,5 16 21,3 360,0 730,0
83705 2 x 0,75 19 6,1 14,4 66,0 83690 34 G 1,5 16 24,1 490,0 945,0
83661 3 G 0,75 19 6,5 22,0 76,0 83691 41 G 1,5 16 26,2 591,0 1135,0
83662 4 G 0,75 19 7,1 29,0 85,0 83692 50 G 1,5 16 28,8 720,0 1381,0
83663 5 G 0,75 19 7,9 36,0 113,0 83693 61 G 1,5 16 31,5 878,0 1640,0
83664 7 G 0,75 19 9,5 50,0 144,0 83708 2 x 2,5 14 9,1 48,0 125,0
83665 12 G 0,75 19 11,6 86,0 245,0 83694 3 G 2,5 14 9,9 72,0 169,0
83666 18 G 0,75 19 13,9 130,0 327,0 83695 4 G 2,5 14 11,0 96,0 209,0
83667 25 G 0,75 19 17,1 180,0 466,0 83696 5 G 2,5 14 12,0 120,0 256,0
83668 34 G 0,75 19 19,1 245,0 626,0 83697 7 G 2,5 14 14,6 168,0 340,0
83669 41 G 0,75 19 20,9 296,0 747,0 83698 12 G 2,5 14 18,1 288,0 579,0
83670 50 G 0,75 19 23,0 360,0 896,0 83699 18 G 2,5 14 22,1 432,0 851,0
83671 61 G 0,75 19 25,3 439,0 1070,0 83700 25 G 2,5 14 26,5 600,0 1175,0
83706 2x1 18 6,4 19,2 70,0 83701 34 G 2,5 14 29,9 816,0 1529,0
83672 3G1 18 6,8 29,0 88,0 83702 50 G 2,5 14 35,2 1200,0 2290,0
83673 4G1 18 7,5 39,0 99,0 83703 61 G 2,5 14 38,4 1464,0 2724,0
83674 5G1 18 8,4 48,0 132,0
83675 7G1 18 10,0 67,0 170,0
83676 12 G 1 18 12,5 115,0 285,0
83677 18 G 1 18 14,7 173,0 405,0
83678 25 G 1 18 18,0 240,0 570,0
358
Cables according to international Approvals / PVC-Control Cables UL/CSA
Application
HELUKABEL TRAYCONTROL 500 is a flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this cable
to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 edition 2012. Approved for open, unprotected
installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life for industrial applications in dry,
damp and wet environments. Recommended applications: production lines, bottling plants, machine construction, switch cabinets, conveyor systems,
packaging machines, automotive industry.
N
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
63079 0,507 2 x 20 6,6 9,8 58,0 63107 1,31 2 x 16 7,8 25,2 80,0
63080 0,507 3 x 20 7,0 14,6 61,0 63108 1,31 3 x 16 8,2 37,8 86,0
63081 0,507 4 x 20 7,5 19,5 76,0 63109 1,31 4 x 16 8,8 50,3 115,0
63082 0,507 5 x 20 8,1 24,4 89,0 63110 1,31 5 x 16 9,6 62,9 126,0
63083 0,507 7 x 20 8,7 34,1 120,0 63112 1,31 6 x 16 10,2 75,5 164,0
63084 0,507 9 x 20 9,8 43,8 201,0 63113 1,31 7 x 16 10,5 88,0 171,0
63085 0,507 12 x 20 10,1 58,4 250,0 63114 1,31 8 x 16 11,1 100,7 201,0
63086 0,507 18 x 20 12,9 87,6 295,0 63115 1,31 9 x 16 12,0 113,2 237,0
63087 0,507 25 x 20 15,7 121,7 362,0 63116 1,31 10 x 16 12,4 125,8 259,0
63088 0,963 2 x 18 7,3 18,5 68,0 63117 1,31 12 x 16 13,6 151,0 301,0
63089 0,963 3 x 18 7,6 27,8 88,0 63118 1,31 14 x 16 14,5 176,1 365,0
63090 0,963 4 x 18 8,2 37,0 98,0 63119 1,31 15 x 16 15,2 188,7 379,0
63091 0,963 5 x 18 8,9 46,3 116,0 63120 1,31 16 x 16 16,0 201,3 405,0
63092 0,963 7 x 18 9,6 64,8 149,0 63121 1,31 18 x 16 16,4 226,4 443,0
63093 0,963 9 x 18 11,0 83,2 186,0 63122 1,31 19 x 16 16,6 239,0 458,0
63094 0,963 10 x 18 11,6 92,5 199,0 63123 1,31 20 x 16 17,2 251,6 491,0
63095 0,963 12 x 18 12,2 111,0 245,0 63124 1,31 25 x 16 18,9 314,5 564,0
63096 0,963 15 x 18 13,5 138,7 292,0 63125 1,31 27 x 16 19,3 339,6 629,0
63097 0,963 16 x 18 13,6 147,9 306,0 63126 1,31 30 x 16 20,0 377,3 701,0
63098 0,963 18 x 18 15,0 166,4 366,0 63127 1,31 34 x 16 22,5 427,6 775,0
63099 0,963 19 x 18 15,1 175,7 384,0 63128 1,31 40 x 16 23,5 503,1 946,0
63100 0,963 25 x 18 17,4 231,2 451,0 63129 1,31 41 x 16 24,0 515,7 967,0
63101 0,963 27 x 18 17,7 249,6 521,0 63130 1,31 50 x 16 26,1 628,8 1137,0
63102 0,963 34 x 18 19,7 314,4 625,0 63131 1,31 61 x 16 27,5 767,2 1345,0
63103 0,963 37 x 18 20,1 342,0 684,0 63132 2,08 2 x 14 8,9 40,0 100,0
63104 0,963 41 x 18 21,0 379,0 744,0 63133 2,08 3 x 14 9,2 60,0 112,0
63105 0,963 50 x 18 24,0 462,3 933,0 63111 2,08 4 x 14 10,1 80,0 141,0
63106 0,963 61 x 18 25,2 564,0 1095,0 63164 2,08 5 x 14 10,9 100,0 152,0
Continuation
359
Cables according to international Approvals / PVC-Control Cables UL/CSA
360
Cables according to international Approvals / PVC-Control Cables UL/CSA
Note
Available on request
with red, black, yellow or orange cores
Black or TPE outer sheath
Application
TRAYCONTROL 530 is a flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this cable to be used as a
connecting cable for AC, DC or control wiring in accordance with NFPA 79 Edition 2012. Approved for open, unprotected installation in cable trays
to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life for industrial applications in dry, damp and wet environments.
Recommended Applications: automotive industry, machine tool, production lines.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
N
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
66840 2x1 18 7,0 19,0 68,0 66862 2 x 1,32 16 7,5 25,0 80,0
66841 3G1 18 7,1 29,0 88,0 66863 3 G 1,32 16 7,8 38,0 86,0
66842 4G1 18 8,0 38,0 98,0 66864 4 G 1,32 16 8,5 51,0 115,0
66843 5G1 18 8,6 48,0 116,0 66865 5 G 1,32 16 9,3 63,0 126,0
66844 7G1 18 9,3 67,0 149,0 66866 7 G 1,32 16 10,1 89,0 171,0
66845 9G1 18 10,7 86,0 186,0 66867 9 G 1,32 16 11,7 114,0 237,0
66846 10 G 1 18 11,6 96,0 199,0 66868 10 G 1,32 16 12,4 127,0 259,0
66847 12 G 1 18 11,9 115,0 245,0 66869 12 G 1,32 16 12,9 152,0 301,0
66848 15 G 1 18 13,2 144,0 292,0 66870 15 G 1,32 16 15,0 190,0 379,0
66849 16 G 1 18 13,3 154,0 306,0 66871 16 G 1,32 16 15,2 203,0 405,0
66850 18 G 1 18 14,6 173,0 366,0 66872 18 G 1,32 16 15,9 228,0 443,0
66851 19 G 1 18 14,7 182,0 384,0 66873 19 G 1,32 16 16,0 241,0 458,0
66852 25 G 1 18 17,0 240,0 451,0 66874 25 G 1,32 16 18,6 317,0 564,0
66853 27 G 1 18 17,4 259,0 521,0 66875 27 G 1,32 16 19,0 342,0 629,0
66854 33 G 1 18 18,7 317,0 590,0 66876 33 G 1,32 16 20,4 418,0 758,0
66855 34 G 1 18 19,3 326,0 625,0 66877 34 G 1,32 16 20,5 431,0 775,0
66856 41 G 1 18 20,7 394,0 744,0 66878 41 G 1,32 16 23,4 520,0 967,0
66857 42 G 1 18 20,8 403,0 758,0 66879 42 G 1,32 16 24,1 532,0 972,0
66858 49 G 1 18 23,0 470,0 917,0 66880 49 G 1,32 16 25,5 621,0 1132,0
66859 50 G 1 18 23,5 480,0 933,0 66881 50 G 1,32 16 25,6 634,0 1137,0
66860 61 G 1 18 24,9 624,0 1095,0 66882 61 G 1,32 16 27,2 773,0 1345,0
66861 65 G 1 18 25,6 624,0 1125,0 66883 65 G 1,32 16 28,5 824,0 1376,0
361
Cables according to international Approvals / PVC-Control Cables UL/CSA
Application
Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning
and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be
used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable
has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The
black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
11815 2 x 0,5 20 6,4 9,6 56,0 11880 2 x 0,5 20 6,4 9,6 56,0
11816 3 G 0,5 20 6,8 14,4 68,0 11881 3 G 0,5 20 6,8 14,4 68,0
11817 4 G 0,5 20 7,6 19,0 100,0 11882 4 G 0,5 20 7,6 19,0 100,0
11818 5 G 0,5 20 8,2 24,0 117,0 11883 5 G 0,5 20 8,2 24,0 117,0
11819 7 G 0,5 20 9,8 33,6 138,0 11884 7 G 0,5 20 9,8 33,6 138,0
11820 12 G 0,5 20 12,2 58,0 200,0 11885 12 G 0,5 20 12,2 58,0 200,0
11821 18 G 0,5 20 14,4 86,0 276,0 11886 18 G 0,5 20 14,4 86,0 276,0
11822 25 G 0,5 20 17,2 120,0 335,0 11887 25 G 0,5 20 17,2 120,0 335,0
11823 2 x 0,75 19 6,8 14,4 66,0 11888 2 x 0,75 19 6,8 14,4 66,0
11824 3 G 0,75 19 7,2 21,6 74,0 11889 3 G 0,75 19 7,2 21,6 74,0
11825 4 G 0,75 19 8,0 29,0 126,0 11890 4 G 0,75 19 8,0 29,0 126,0
11826 5 G 0,75 19 8,8 36,0 140,0 11891 5 G 0,75 19 8,8 36,0 140,0
11827 7 G 0,75 19 10,7 50,0 190,0 11892 7 G 0,75 19 10,7 50,0 190,0
11828 12 G 0,75 19 13,1 86,0 257,0 11893 12 G 0,75 19 13,1 86,0 257,0
11829 18 G 0,75 19 15,6 130,0 362,0 11894 18 G 0,75 19 15,6 130,0 362,0
11830 25 G 0,75 19 18,9 180,0 486,0 11895 25 G 0,75 19 18,9 180,0 486,0
11831 2x1 18 7,4 19,2 80,0 11896 2x1 18 7,4 19,2 80,0
11832 3G1 18 8,0 29,2 96,0 11897 3G1 18 8,0 29,2 96,0
11833 4G1 18 8,8 38,4 100,0 11898 4G1 18 8,8 38,4 100,0
11834 5G1 18 9,8 48,0 130,0 11899 5G1 18 9,8 48,0 130,0
11835 7G1 18 11,7 67,0 170,0 11900 7G1 18 11,7 67,0 170,0
11836 12 G 1 18 14,5 115,0 290,0 11901 12 G 1 18 14,5 115,0 290,0
11837 18 G 1 18 17,3 173,0 405,0 11902 18 G 1 18 17,3 173,0 405,0
11838 25 G 1 18 21,1 240,0 570,0 11903 25 G 1 18 21,1 240,0 570,0
11839 2 x 1,5 16 8,4 29,0 95,0 11904 2 x 1,5 16 8,4 29,0 95,0
11840 3 G 1,5 16 9,1 43,0 112,0 11905 3 G 1,5 16 9,1 43,0 112,0
11841 4 G 1,5 16 9,9 58,0 139,0 11906 4 G 1,5 16 9,9 58,0 139,0
11842 5 G 1,5 16 11,0 72,0 170,0 11907 5 G 1,5 16 11,0 72,0 170,0
11843 7 G 1,5 16 13,3 101,0 225,0 11908 7 G 1,5 16 13,3 101,0 225,0
11844 12 G 1,5 16 16,6 173,0 370,0 11909 12 G 1,5 16 16,6 173,0 370,0
11845 18 G 1,5 16 19,7 259,0 520,0 11910 18 G 1,5 16 19,7 259,0 520,0
11846 25 G 1,5 16 23,9 360,0 730,0 11911 25 G 1,5 16 23,9 360,0 730,0
Continuation
362
Cables according to international Approvals / PVC-Control Cables UL/CSA
363
Cables according to international Approvals / PVC-Control Cables UL/CSA
Application
USA NFPA79, edition 2012 conformant flexible power cables up to 600 V, for all machinery in tool and plant constuction, suitable for installation in
dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation from the cable rack
to machines and industrial plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
69661 2x1 18 8,0 19,2 72,0 69689 2 x 2,5 14 9,4 48,0 108,0
69662 3G1 18 8,4 29,0 84,0 69690 3 G 2,5 14 9,9 72,0 137,0
69663 4G1 18 9,1 39,0 96,0 69691 4 G 2,5 14 10,8 96,0 157,0
69664 5G1 18 10,0 48,0 114,0 69692 5 G 2,5 14 11,8 120,0 190,0
69665 7G1 18 11,7 67,0 147,0 69693 7 G 2,5 14 14,7 168,0 253,0
69666 9G1 18 12,6 84,0 172,0 69694 8 G 2,5 14 16,0 192,0 339,0
69667 10 G 1 18 14,3 96,0 206,0 69695 9 G 2,5 14 16,0 216,0 341,0
69668 12 G 1 18 14,7 115,0 256,0 69696 10 G 2,5 14 17,1 240,0 392,0
69669 18 G 1 18 17,1 173,0 367,0 69697 12 G 2,5 14 17,7 288,0 470,0
69670 25 G 1 18 20,3 240,0 477,0 69698 18 G 2,5 14 20,8 432,0 682,0
69671 34 G 1 18 23,7 326,0 551,0 69699 25 G 2,5 14 25,8 600,0 891,0
69672 50 G 1 18 26,1 480,0 959,0 69700 3G4 12 11,0 115,0 187,0
69673 2 x 1,5 16 8,4 28,8 88,0 69701 4G4 12 12,0 154,0 226,0
69674 3 G 1,5 16 8,8 43,0 102,0 69702 5G4 12 13,2 192,0 280,0
69675 4 G 1,5 16 9,6 58,0 119,0 69703 7G4 12 16,5 269,0 390,0
69676 5 G 1,5 16 10,5 72,0 144,0 69704 9G4 12 17,8 346,0 480,0
69677 7 G 1,5 16 12,3 101,0 192,0 69705 12 G 4 12 19,9 461,0 841,0
69678 8 G 1,5 16 13,3 115,0 213,0 69706 18 G 4 12 24,2 691,0 981,0
69679 9 G 1,5 16 13,3 130,0 261,0 69707 3G6 10 12,5 173,0 290,0
69680 10 G 1,5 16 15,1 144,0 294,0 69708 4G6 10 14,5 230,0 381,0
69681 12 G 1,5 16 15,6 173,0 328,0 69709 5G6 10 15,8 288,0 465,0
69682 16 G 1,5 16 17,1 230,0 402,0 69710 7G6 10 17,3 403,0 654,0
69683 18 G 1,5 16 18,2 259,0 427,0 69711 3 G 10 8 16,9 288,0 511,0
69684 25 G 1,5 16 22,7 360,0 594,0 69712 4 G 10 8 18,6 384,0 584,0
69685 34 G 1,5 16 25,3 489,0 714,0 69713 5 G 10 8 20,4 480,0 781,0
69686 41 G 1,5 16 27,0 590,0 803,0 69714 7 G 10 8 23,5 672,0 970,0
69687 50 G 1,5 16 27,3 720,0 1021,0
69688 61 G 1,5 16 29,4 878,0 1238,0
Continuation
364
Cables according to international Approvals / PVC-Control Cables UL/CSA
365
Cables according to international Approvals / PVC-Control Cables UL/CSA
Note
Advantages
TC-ER, Tray Cable Exposed Run
simple Installation
outstanding flexibility
Application
USA NFPA 79 edition 2012 conformant flexible power cables up to 600 V (WTTC 1000 V), for all machinery in tool and plant constuction, suitable
for installation in dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation
from the cable rack to machines and industrial plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62020 0,507 2 x 20 6,6 9,8 60,0 62923 1,31 4 x 16 8,8 50,3 120,0
62021 0,507 3 x 20 7,0 14,6 64,0 62924 1,31 5 x 16 9,6 62,9 130,0
62022 0,507 4 x 20 7,5 19,5 79,0 62925 1,31 6 x 16 10,2 75,5 164,0
62023 0,507 5 x 20 8,1 24,4 92,0 62926 1,31 7 x 16 10,5 88,0 188,0
62024 0,507 7 x 20 8,7 34,1 124,0 62927 1,31 8 x 16 11,1 100,7 201,0
62025 0,507 9 x 20 9,8 43,8 210,0 62928 1,31 9 x 16 12,0 113,2 238,0
62026 0,507 12 x 20 10,1 58,4 263,0 62929 1,31 10 x 16 12,4 125,8 259,0
62027 0,507 18 x 20 12,9 87,6 305,0 62930 1,31 12 x 16 13,6 151,0 301,0
62028 0,507 25 x 20 15,7 121,7 371,0 62931 1,31 14 x 16 14,5 176,1 356,0
62902 0,963 2 x 18 7,3 18,5 68,0 62932 1,31 15 x 16 15,2 188,7 379,0
62903 0,963 3 x 18 7,6 27,8 68,0 62933 1,31 16 x 16 16,0 201,3 405,0
62904 0,963 4 x 18 8,2 37,0 97,0 62934 1,31 18 x 16 16,4 226,4 430,0
62905 0,963 5 x 18 8,9 46,3 116,0 62935 1,31 19 x 16 16,6 239,0 450,0
62906 0,963 7 x 18 9,6 64,8 147,0 62936 1,31 20 x 16 17,2 251,6 481,0
62907 0,963 9 x 18 11,0 83,2 186,0 62937 1,31 25 x 16 18,9 314,5 564,0
62908 0,963 10 x 18 11,6 92,5 199,0 62938 1,31 27 x 16 19,3 339,6 629,0
62909 0,963 12 x 18 12,2 111,0 250,0 62939 1,31 30 x 16 20,0 377,3 701,0
62910 0,963 15 x 18 13,5 138,7 292,0 62940 1,31 34 x 16 22,5 427,6 775,0
62911 0,963 16 x 18 13,6 147,9 306,0 62941 1,31 40 x 16 23,5 503,1 946,0
62912 0,963 18 x 18 15,0 166,4 365,0 62942 1,31 41 x 16 24,0 515,7 967,0
62913 0,963 19 x 18 15,1 175,7 384,0 62943 1,31 50 x 16 26,1 628,8 1137,0
62914 0,963 25 x 18 17,4 231,2 480,0 62944 1,31 61 x 16 27,5 767,2 1345,0
62915 0,963 27 x 18 17,7 249,6 521,0 62945 2,08 2 x 14 8,9 40,0 100,0
62916 0,963 34 x 18 19,7 314,4 625,0 62946 2,08 3 x 14 9,2 60,0 117,0
62917 0,963 37 x 18 20,1 342,0 684,0 62947 2,08 4 x 14 10,1 80,0 141,0
62918 0,963 41 x 18 21,0 379,0 744,0 62948 2,08 5 x 14 10,9 100,0 152,0
62919 0,963 50 x 18 24,0 462,3 933,0 62949 2,08 6 x 14 11,5 120,0 216,0
62920 0,963 61 x 18 25,2 564,0 1095,0 62950 2,08 7 x 14 12,0 140,0 255,0
62921 1,31 2 x 16 7,8 25,2 80,0 62951 2,08 9 x 14 14,7 180,0 312,0
62922 1,31 3 x 16 8,2 37,8 86,0 62952 2,08 10 x 14 15,8 200,0 378,0
Continuation
366
Cables according to international Approvals / PVC-Control Cables UL/CSA
367
Cables according to international Approvals / PVC-Control Cables UL/CSA
H05VV-F/SJT 300 V
Application
These flexible PVC control cables, VDE-HAR-UL-CSA approved, are designed for the export and also for the export-orientated-equipment. These
cables are especially suited to use for the appliance with medium mechanical stresses with free movement without tensile stress in households, kitchens
and offices, also for household appliances in damp and wet areas, e. g. refrigerators, washing machines, spin-driver etc. , as far as this cable is admitted
to the relevant specifications of the equipment. These cables are suited to be used for cooking and heating apparatus under the condition that cable
does not come in direct contact with hot parts of the apparatus and no other influences or heat. The cables are suitable for fixed installation in furnitures,
partition walls, decoration covering and in hollow spaces of prefabricated building parts. They are not suitable for use in open air, in industries (also
permitted to tailor workshops and of that kind) and in agriculture plants and for connecting commercial electrical tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Cross- No.cores Sheath Outer Cop. Weight Part no. Cross- No.cores Sheath Outer Cop. Weight
section x colour app. mm weight app. section x colour app. mm weight app.
mm AWG-No. kg / km kg / km mm AWG-No. kg / km kg / km
28034 1,04 2 x 17 black 7,4 20,0 86,0 28042 2,63 2 x 13 black 9,5 50,5 150,0
28066 1,04 2 x 17 grey 7,4 20,0 86,0 28074 2,63 2 x 13 grey 9,5 50,5 150,0
28050 1,04 2 x 17 white 7,4 20,0 86,0 28058 2,63 2 x 13 white 9,5 50,5 150,0
28035 1,04 3 x 17 black 7,9 30,0 98,0 28043 2,63 3 x 13 black 10,2 75,7 184,0
28067 1,04 3 x 17 grey 7,9 30,0 98,0 28075 2,63 3 x 13 grey 10,2 75,7 184,0
28051 1,04 3 x 17 white 7,9 30,0 98,0 28059 2,63 3 x 13 white 10,2 75,7 184,0
28036 1,04 4 x 17 black 8,8 40,0 123,0 28044 2,63 4 x 13 black 11,2 101,0 229,0
28068 1,04 4 x 17 grey 8,8 40,0 123,0 28076 2,63 4 x 13 grey 11,2 101,0 229,0
28052 1,04 4 x 17 white 8,8 40,0 123,0 28060 2,63 4 x 13 white 11,2 101,0 229,0
28037 1,04 5 x 17 black 9,6 50,0 146,0 28045 2,63 5 x 13 black 12,5 126,2 281,0
28069 1,04 5 x 17 grey 9,6 50,0 146,0 28077 2,63 5 x 13 grey 12,5 126,2 281,0
28053 1,04 5 x 17 white 9,6 50,0 146,0 28061 2,63 5 x 13 white 12,5 126,2 281,0
28038 1,65 2 x 15 black 8,1 31,7 106,0 28046 4,17 2 x 11 black 10,8 80,1 204,0
28070 1,65 2 x 15 grey 8,1 31,7 106,0 28078 4,17 2 x 11 grey 10,8 80,1 204,0
28054 1,65 2 x 15 white 8,1 31,7 106,0 28062 4,17 2 x 11 white 10,8 80,1 204,0
28039 1,65 3 x 15 black 8,7 47,5 128,0 28047 4,17 3 x 11 black 11,6 120,1 254,0
28071 1,65 3 x 15 grey 8,7 47,5 128,0 28079 4,17 3 x 11 grey 11,6 120,1 254,0
28055 1,65 3 x 15 white 8,7 47,5 128,0 28063 4,17 3 x 11 white 11,6 120,1 254,0
28040 1,65 4 x 15 black 9,8 63,4 164,0 28048 4,17 4 x 11 black 12,8 160,1 315,0
28072 1,65 4 x 15 grey 9,8 63,4 164,0 28080 4,17 4 x 11 grey 12,8 160,1 315,0
28056 1,65 4 x 15 white 9,8 63,4 164,0 28064 4,17 4 x 11 white 12,8 160,1 315,0
28041 1,65 5 x 15 black 10,8 79,2 201,0 28049 4,17 5 x 11 black 14,4 200,2 393,0
28073 1,65 5 x 15 grey 10,8 79,2 201,0 28081 4,17 5 x 11 grey 14,4 200,2 393,0
28057 1,65 5 x 15 white 10,8 79,2 201,0 28065 4,17 5 x 11 white 14,4 200,2 393,0
368
Cables according to international Approvals / PVC-Control Cables UL/CSA
H05VV-F/SJT 300 V
Application
These flexible PVC control cables, VDE-HAR-UL-CSA approved, are designed for the export and also for the export-orientated-equipment. These
cables are especially suited to use for the appliance with medium mechanical stresses with free movement without tensile stress in households, kitchens
and offices, also for household appliances in damp and wet areas, e. g. refrigerators, washing machines, spin-driver etc. , as far as this cable is admitted
to the relevant specifications of the equipment. These cables are suited to be used for cooking and heating apparatus under the condition that cable
does not come in direct contact with hot parts of the apparatus and no other influences or heat. The cables are suitable for fixed installation in furnitures, N
partition walls, decoration covering and in hollow spaces of prefabricated building parts. They are not suitable for use in open air, in industries (also
permitted to tailor workshops and of that kind) and in agriculture plants and for connecting commercial electrical tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
3110x 1,04 2 x 17 7,4 20,0 86,0 3118x 2,63 2 x 13 9,5 50,5 150,0
3111x 1,04 3 G 17 7,9 30,0 98,0 3119x 2,63 3 G 13 10,2 75,7 184,0
3112x 1,04 4 G 17 8,8 40,0 123,0 3120x 2,63 4 G 13 11,2 101,0 229,0
3113x 1,04 5 G 17 9,6 50,0 146,0 3121x 2,63 5 G 13 12,5 126,2 281,0
3114x 1,65 2 x 15 8,1 31,7 106,0 3122x 4,17 2 x 11 10,8 80,1 204,0
3115x 1,65 3 G 15 8,7 47,5 128,0 3123x 4,17 3 G 11 11,6 120,1 254,0
3116x 1,65 4 G 15 9,8 63,4 164,0 3124x 4,17 4 G 11 12,8 160,1 315,0
3117x 1,65 5 G 15 10,8 79,2 201,0 3125x 4,17 5 G 11 14,4 200,2 393,0
369
Cables according to international Approvals / PVC-Control Cables UL
H05VV-F/UL 500 V
Application
These flexible PVC control cables, VDE-HAR-AWM approved, are designed for the export and also for the export-orientated-equipment. These cables
are especially suited to use for the appliance with medium mechanical stresses with free movement without tensile stress in households, kitchens and
offices, also for household appliances in damp and wet areas, e. g. refrigerators, washing machines, spin-driver etc. , as far as this cable is admitted
to the relevant specifications of the equipment. These cables are suited to be used for cooking and heating apparatus under the condition that cable
does not come in direct contact with hot parts of the apparatus and no other influences or heat. The cables are suitable for fixed installation in furnitures,
partition walls, decoration covering and in hollow spaces of prefabricated building parts. They are not suitable for use in open air, in industries (also
permitted to tailor workshops and of that kind) and in agriculture plants and for connecting commercial electrical tools.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
3269x 2 x 0,75 18 6,4 14,4 50,0 3279x 4 G 1,5 15 9,3 58,0 117,0
3270x 3 G 0,75 18 6,8 21,6 60,0 3280x 5 G 1,5 15 10,4 72,0 144,0
3271x 4 G 0,75 18 7,4 29,0 73,0 3281x 3 G 2,5 13 10,0 72,0 152,0
3272x 5 G 0,75 18 8,3 36,0 88,0 3282x 4 G 2,5 13 10,9 96,0 192,0
3273x 2x1 17 7,3 19,0 57,0 3283x 5 G 2,5 13 12,2 120,0 243,0
3274x 3G1 17 7,8 29,0 73,0
3275x 4G1 17 8,6 38,0 85,0
3276x 5G1 17 9,4 48,0 105,0
3277x 2 x 1,5 15 7,9 29,0 82,0
3278x 3 G 1,5 15 8,4 43,0 95,0
370
Cables according to international Approvals / PVC-Control Cables
Application
Well known companies (FIAT, COMAU, etc.) use this cable for measurement and control purposes on machine tools and conveyors, as well as on
production lines in equipment production and for special mechanical engineering. These cables are used for flexible use for medium mechanical stresses
with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. Due to special conductor
insulation- and sheath compound, this cable is flame resistant in case of fire and self-extinguishing. The good oil- and petrol resistance allows the
usage of this cable also in problem areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
60250
60251
mm
3G1
4G1
8,5
9,5
kg / km
29,0
39,0
85,0
100,0
17
17
60287
60270
mm
3 G 2,5
4 G 2,5
11,3
12,3
kg / km
72,0
96,0
190,0
215,0
14
14
N
60252 5G1 10,5 48,0 123,0 17 60271 5 G 2,5 12,6 120,0 270,0 14
60253 7G1 10,8 67,0 160,0 17 60272 7 G 2,5 14,5 168,0 350,0 14
60254 12 G 1 13,8 115,0 270,0 17 60273 12 G 2,5 18,0 288,0 550,0 14
60255 18 G 1 16,5 173,0 380,0 17 60274 4G4 14,0 154,0 300,0 12
60256 25 G 1 19,5 240,0 500,0 17 60275 7G4 16,0 269,0 500,0 12
60284 27 G 1 20,0 259,0 560,0 17 60276 4G6 16,0 230,0 430,0 10
60285 33 G 1 20,8 317,0 700,0 17 60277 4 G 10 19,0 384,0 700,0 8
60257 34 G 1 21,0 326,0 720,0 17 60278 4 G 16 23,0 614,0 1000,0 6
60258 42 G 1 23,3 405,0 800,0 17 60279 4 G 25 28,0 960,0 1550,0 4
60259 50 G 1 25,0 480,0 1050,0 17 60280 4 G 35 31,0 1344,0 2070,0 2
60260 3 G 1,5 9,6 43,0 105,0 16 60281 4 G 50 37,0 1920,0 2850,0 1
60261 4 G 1,5 11,0 58,0 150,0 16 60282 4 G 70 43,0 2688,0 4000,0 2/0
60262 5 G 1,5 12,0 72,0 190,0 16 60283 4 G 95 50,0 3648,0 5400,0 3/0
60263 7 G 1,5 12,5 101,0 220,0 16
60264 12 G 1,5 16,0 173,0 350,0 16
60265 18 G 1,5 18,8 259,0 515,0 16
60266 25 G 1,5 23,0 360,0 705,0 16
60267 34 G 1,5 26,0 490,0 990,0 16
60286 37 G 1,5 26,5 533,0 1005,0 16
60268 42 G 1,5 29,5 605,0 1080,0 16
60269 50 G 1,5 30,5 720,0 1330,0 16
371
Cables according to international Approvals / PVC-Control Cables
Application
These cables are constructed specially for the french automobile industries and used for the installation in tool making machines, production lines,
industrial plants, air conditioning as well as for use in steel production. These cables are used for flexible use for medium mechanical stresses with free
movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
60000 2 x 0,75 6,2 14,4 50,0 18 60034 2 x 2,5 10,5 48,0 122,0 14
60001 3 G 0,75 6,6 21,6 59,0 18 60035 3 G 2,5 11,0 72,0 151,0 14
60002 4 G 0,75 7,2 29,0 72,0 18 60036 4 G 2,5 12,0 96,0 191,0 14
60003 5 G 0,75 8,0 36,0 87,0 18 60037 5 G 2,5 13,1 120,0 244,0 14
60004 6 G 0,75 8,9 50,0 105,0 18 60038 6 G 2,5 15,0 168,0 292,0 14
60005 12 G 0,75 11,6 86,0 175,0 18 60039 12 G 2,5 18,0 288,0 524,0 14
60006 18 G 0,75 13,9 144,0 267,0 18 60040 2x4 10,4 77,0 178,0 12
60007 27 G 0,75 17,2 230,0 404,0 18 60041 3G4 11,3 115,0 230,0 12
60008 36 G 0,75 19,7 288,0 503,0 18 60042 4G4 12,8 154,0 300,0 12
60009 48 G 0,75 22,8 360,0 670,0 18 60043 5G4 14,2 192,0 362,0 12
60010 60 G 0,75 24,9 439,0 805,0 18 60044 2x6 11,6 115,0 218,0 10
60011 2x1 6,5 19,0 56,0 17 60045 3G6 12,7 173,0 325,0 10
60012 3G1 6,9 29,0 72,0 17 60046 4G6 14,2 230,0 481,0 10
60013 4G1 7,7 38,0 84,0 17 60047 5G6 15,7 288,0 584,0 10
60014 5G1 8,5 48,0 104,0 17 60048 2 x 10 15,0 194,0 505,0 8
60015 6G1 9,2 67,0 124,0 17 60049 3 G 10 16,6 288,0 610,0 8
60016 12 G 1 12,4 115,0 219,0 17 60050 4 G 10 18,4 384,0 736,0 8
60017 18 G 1 15,2 192,0 314,0 17 60051 5 G 10 20,9 480,0 913,0 8
60018 27 G 1 18,7 308,0 485,0 17
60019 36 G 1 21,1 384,0 620,0 17
60020 48 G 1 24,3 480,0 809,0 17
60021 60 G 1 26,4 586,0 1000,0 17
60022 2 x 1,5 7,5 29,0 76,0 16
60023 3 G 1,5 8,1 43,0 94,0 16
60024 4 G 1,5 9,1 58,0 116,0 16
60025 5 G 1,5 10,1 72,0 143,0 16
60026 6 G 1,5 11,0 101,0 173,0 16
60027 12 G 1,5 15,1 173,0 307,0 16
60028 18 G 1,5 17,9 263,0 464,0 16
60029 24 G 1,5 21,0 341,0 629,0 16
60030 27 G 1,5 21,8 372,0 708,0 16
60031 36 G 1,5 24,5 498,0 985,0 16
60032 48 G 1,5 28,4 641,0 1175,0 16
60033 60 G 1,5 31,3 878,0 1415,0 16
372
Cables according to international Approvals / PVC-Control Cables UL/CSA
Application
UL and CSA approved flexible control cables up to 600 V, for all machinery in tooling and plant construction, suitable for installation in dry, moist or
wet environments for medium mechanical loads. Designed for the export-orientated machinery manufacturer, specifically for USA and Canada. The
thick braiding screen ensures compliance with electromagnetic requirements.
EMC = Electromagnetic compatibillity
N
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
82990 2 x 0,5 20 7,4 35,0 93,0 82977 34 G 1,5 16 25,2 629,0 1203,0
82991 3 G 0,5 20 7,7 42,0 124,0 82978 41 G 1,5 16 27,6 801,0 1588,0
82992 4 G 0,5 20 8,2 47,0 133,0 82959 2 x 2,5 14 10,1 96,0 173,0
82993 5 G 0,5 20 9,0 56,0 153,0 82960 3 G 2,5 14 10,6 144,0 220,0
82994 7 G 0,5 20 9,6 69,0 191,0 82961 4 G 2,5 14 11,6 148,0 270,0
82995 9 G 0,5 20 11,2 87,0 243,0 82962 5 G 2,5 14 12,7 181,0 329,0
82996 12 G 0,5 20 12,3 108,0 322,0 82963 7 G 2,5 14 14,0 255,0 428,0
82997 18 G 0,5 20 14,7 145,0 374,0 82964 9 G 2,5 14 16,4 309,0 580,0
82998 25 G 0,5 20 17,0 240,0 436,0 82965 12 G 2,5 14 18,1 441,0 761,0
82999 34 G 0,5 20 21,4 312,0 560,0 82966 18 G 2,5 14 22,2 570,0 1140,0
83000 41 G 0,5 20 21,4 348,0 663,0 82967 25 G 2,5 14 27,0 738,0 1551,0
82979 2x1 18 8,1 50,0 107,0 82954 2x4 12 11,2 120,0 209,0
82980 3G1 18 8,5 60,0 130,0 82955 3G4 12 11,9 174,0 310,0
82981 4G1 18 9,2 71,0 155,0 82956 4G4 12 13,3 230,0 456,0
82982 5G1 18 10,1 88,0 181,0 82957 5G4 12 14,6 273,0 532,0
82983 7G1 18 10,8 111,0 209,0 82958 7G4 12 15,9 316,0 737,0
82984 9G1 18 12,7 139,0 321,0 82949 2x6 10 12,9 173,0 318,0
82985 12 G 1 18 14,1 184,0 341,0 82950 3G6 10 14,0 240,0 411,0
82986 18 G 1 18 16,6 260,0 473,0 82951 4G6 10 15,4 305,0 572,0
82987 25 G 1 18 19,7 349,0 650,0 82952 5G6 10 17,0 439,0 732,0
82988 34 G 1 18 22,6 486,0 781,0 82953 7G6 10 18,3 505,0 961,0
82989 41 G 1 18 24,7 531,0 892,0 82945 3 G 10 8 16,3 350,0 741,0
82968 2 x 1,5 16 8,6 63,0 136,0 82946 4 G 10 8 19,4 535,0 988,0
82969 3 G 1,5 16 9,2 80,0 165,0 82947 5 G 10 8 21,6 592,0 1202,0
82970 4 G 1,5 16 10,0 97,0 192,0 82948 7 G 10 8 23,9 810,0 1743,0
82971 5 G 1,5 16 11,0 119,0 224,0 82941 3 G 16 6 23,9 585,0 1088,0
82972 7 G 1,5 16 11,8 147,0 273,0 82942 4 G 16 6 26,4 740,0 1662,0
82973 9 G 1,5 16 14,0 182,0 340,0
82974 12 G 1,5 16 15,3 267,0 461,0
82975 18 G 1,5 16 18,5 374,0 674,0
82976 25 G 1,5 16 21,8 526,0 950,0
Continuation
373
Cables according to international Approvals / PVC-Control Cables UL/CSA
374
Cables according to international Approvals / PVC-Control Cables UL/CSA
Application
UL-CSA-HAR approved cables offer any company exporting anywhere in the world, primarily designed for exporters, used in machine tools, control
systems, assembly lines and other industrial equipment. These cables are suitable for flexible use for medium mechanical stresses with free movements
in dry, moist and wet rooms but not for open air.
EMC = Electromagnetic compatibillity N
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
83709 2 x 0,5 20 8,0 41,0 90,0 83747 18 G 1 18 17,3 284,0 560,0
83720 3 G 0,5 20 8,3 45,0 105,0 83748 25 G 1 18 21,1 387,0 760,0
83721 4 G 0,5 20 8,9 54,0 123,0 83749 34 G 1 18 23,5 500,0 945,0
83722 5 G 0,5 20 9,7 66,0 147,0 83750 41 G 1 18 25,5 578,0 1151,0
83723 7 G 0,5 20 11,2 79,0 195,0 83751 50 G 1 18 27,6 681,0 1300,0
83724 12 G 0,5 20 13,6 137,0 276,0 83752 61 G 1 18 32,4 710,0 1500,0
83725 18 G 0,5 20 15,4 156,0 418,0 83712 2 x 1,5 16 9,6 64,0 144,0
83726 25 G 0,5 20 18,6 250,0 504,0 83753 3 G 1,5 16 10,1 82,0 160,0
83727 34 G 0,5 20 20,8 316,0 632,0 83754 4 G 1,5 16 11,0 99,0 210,0
83728 41 G 0,5 20 22,6 348,0 750,0 83755 5 G 1,5 16 12,3 123,0 240,0
83729 50 G 0,5 20 24,8 407,0 968,0 83756 7 G 1,5 16 14,2 148,0 305,0
83730 61 G 0,5 20 26,0 520,0 1068,0 83757 12 G 1,5 16 17,1 274,0 482,0
83710 2 x 0,75 19 8,3 46,0 101,0 83758 18 G 1,5 16 20,0 386,0 611,0
83731 3 G 0,75 19 8,6 57,0 127,0 83759 25 G 1,5 16 24,0 531,0 950,0
83732 4 G 0,75 19 9,4 63,0 155,0 83760 34 G 1,5 16 27,1 671,0 1200,0
83733 5 G 0,75 19 10,1 76,0 180,0 83761 41 G 1,5 16 29,7 840,0 1400,0
83734 7 G 0,75 19 11,9 100,0 225,0 83762 50 G 1,5 16 31,8 997,0 1665,0
83735 12 G 0,75 19 14,2 175,0 326,0 83763 61 G 1,5 16 34,6 1120,0 1852,0
83736 18 G 0,75 19 16,6 240,0 457,0 83713 2 x 2,5 14 11,4 110,0 189,0
83737 25 G 0,75 19 20,0 306,0 635,0 83764 3 G 2,5 14 12,0 148,0 244,0
83738 34 G 0,75 19 22,4 346,0 805,0 83765 4 G 2,5 14 13,4 169,0 296,0
83739 41 G 0,75 19 24,0 403,0 908,0 83766 5 G 2,5 14 14,6 220,0 367,0
83740 50 G 0,75 19 26,2 470,0 1155,0 83767 7 G 2,5 14 17,2 284,0 478,0
83741 61 G 0,75 19 30,0 550,0 1400,0 83768 12 G 2,5 14 21,2 470,0 622,0
83711 2x1 18 8,6 54,0 113,0 83769 18 G 2,5 14 24,8 572,0 1010,0
83742 3G1 18 9,2 64,0 144,0 83770 25 G 2,5 14 29,8 740,0 1375,0
83743 4G1 18 9,8 76,0 178,0 83771 34 G 2,5 14 33,4 1179,0 1893,0
83744 5G1 18 10,7 89,0 205,0 83772 50 G 2,5 14 39,0 1660,0 2666,0
83745 7G1 18 12,5 114,0 263,0 83773 61 G 2,5 14 41,0 1992,0 3077,0
83746 12 G 1 18 15,1 186,0 424,0
375
Cables according to international Approvals / PVC-Control Cables UL/CSA
Application
HELUKABEL TRAYCONTROL 500-C is a flexible, screened and oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER
allows this cable to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 edition 2012. Approved for open,
unprotected installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life for industrial applications
in dry, damp and wet environments. Recommended applications: production lines, bottling plants, machine construction, switch cabinets, conveyor
systems, packaging machines, automotive industry.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62813 0,507 2 x 20 7,0 35,0 95,0 62841 1,31 20 x 16 17,5 340,0 524,0
62814 0,507 3 x 20 7,6 42,0 115,0 62842 1,31 25 x 16 19,6 434,0 704,0
62815 0,507 7 x 20 9,4 69,0 164,0 62843 2,08 3 x 14 9,8 112,0 179,0
62816 0,507 12 x 20 11,0 108,0 266,0 62844 2,08 4 x 14 10,7 121,0 222,0
62817 0,507 25 x 20 16,1 240,0 435,0 62845 2,08 5 x 14 11,6 150,0 266,0
62818 0,963 2 x 18 8,1 50,0 110,0 62846 2,08 7 x 14 12,5 200,0 326,0
62819 0,963 3 x 18 8,2 60,0 118,0 62847 2,08 9 x 14 15,0 240,0 435,0
62820 0,963 4 x 18 8,8 71,0 136,0 62848 2,08 10 x 14 16,3 264,0 427,0
62821 0,963 5 x 18 9,4 88,0 148,0 62849 2,08 12 x 14 16,9 350,0 592,0
62822 0,963 7 x 18 10,1 111,0 192,0 62850 2,08 15 x 14 18,3 409,0 635,0
62823 0,963 9 x 18 11,4 140,0 244,0 62851 2,08 18 x 14 19,5 471,0 780,0
62824 0,963 10 x 18 12,0 150,0 283,0 62852 2,08 19 x 14 19,7 505,0 799,0
62825 0,963 12 x 18 12,9 184,0 329,0 62853 2,08 25 x 14 23,3 652,0 1042,0
62826 0,963 15 x 18 14,8 207,0 377,0 62854 3,31 3 x 12 11,4 137,0 237,0
62827 0,963 18 x 18 15,7 260,0 435,0 62855 3,31 4 x 12 12,2 169,0 314,0
62828 0,963 19 x 18 15,7 280,0 443,0 62856 3,31 5 x 12 13,4 201,0 386,0
62829 0,963 25 x 18 17,7 349,0 571,0 62857 3,31 6 x 12 14,6 236,0 425,0
62830 1,31 3 x 16 8,9 74,0 144,0 62858 3,31 7 x 12 15,5 262,0 496,0
62831 1,31 4 x 16 9,6 90,0 172,0 62859 3,31 9 x 12 17,7 334,0 740,0
62832 1,31 5 x 16 10,3 104,0 188,0 62860 3,31 12 x 12 19,7 434,0 887,0
62833 1,31 6 x 16 10,5 120,0 203,0 62861 3,31 15 x 12 21,0 531,0 903,0
62834 1,31 7 x 16 11,3 134,0 244,0 62862 3,31 19 x 12 23,1 720,0 1123,0
62835 1,31 9 x 16 12,6 165,0 308,0 62863 3,31 20 x 12 25,0 764,0 1490,0
62836 1,31 10 x 16 12,9 180,0 346,0 62864 3,31 25 x 12 27,1 914,0 1865,0
62837 1,31 12 x 16 15,1 244,0 423,0 62865 5,26 3 x 10 14,1 240,0 389,0
62838 1,31 15 x 16 16,4 270,0 441,0 62866 5,26 4 x 10 15,5 305,0 549,0
62839 1,31 18 x 16 17,3 319,0 512,0 62867 5,26 5 x 10 16,8 399,0 610,0
62840 1,31 19 x 16 17,6 327,0 503,0 62868 5,26 7 x 10 18,2 505,0 851,0
Continuation
376
Cables according to international Approvals / PVC-Control Cables UL/CSA
377
Cables according to international Approvals / PVC-Control Cables UL/CSA
Application
PVC control cable for measuring, monitoring and control purposes in tool machinery, conveyor belts and production lines in machinery, in air
conditioning, in foundries and steel mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile
stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be used
as direct burrial- or as underwater cable. Interference-free transmission of signals and pulses is assured by the high degree of screening.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
12345 2 x 0,5 20 8,3 41,0 129,0 12410 2 x 0,5 20 8,3 41,0 129,0
12346 3 G 0,5 20 8,6 45,0 150,0 12411 3 G 0,5 20 8,6 45,0 150,0
12347 4 G 0,5 20 9,4 54,0 170,0 12412 4 G 0,5 20 9,4 54,0 170,0
12348 5 G 0,5 20 10,1 66,0 199,0 12413 5 G 0,5 20 10,1 66,0 199,0
12349 7 G 0,5 20 12,1 79,0 235,0 12414 7 G 0,5 20 12,1 79,0 235,0
12350 12 G 0,5 20 14,7 137,0 320,0 12415 12 G 0,5 20 14,7 137,0 320,0
12351 18 G 0,5 20 17,3 156,0 428,0 12416 18 G 0,5 20 17,3 156,0 428,0
12352 25 G 0,5 20 20,6 250,0 503,0 12417 25 G 0,5 20 20,6 250,0 503,0
12353 2 x 0,75 19 8,7 46,0 143,0 12418 2 x 0,75 19 8,7 46,0 143,0
12354 3 G 0,75 19 9,0 57,0 155,0 12419 3 G 0,75 19 9,0 57,0 155,0
12355 4 G 0,75 19 9,9 63,0 190,0 12420 4 G 0,75 19 9,9 63,0 190,0
12356 5 G 0,75 19 10,8 76,0 228,0 12421 5 G 0,75 19 10,8 76,0 228,0
12357 7 G 0,75 19 13,0 100,0 323,0 12422 7 G 0,75 19 13,0 100,0 323,0
12358 12 G 0,75 19 15,8 175,0 410,0 12423 12 G 0,75 19 15,8 175,0 410,0
12359 18 G 0,75 19 17,9 240,0 560,0 12424 18 G 0,75 19 17,9 240,0 560,0
12360 25 G 0,75 19 22,8 306,0 730,0 12425 25 G 0,75 19 22,8 306,0 730,0
12361 2x1 18 9,4 54,0 150,0 12426 2x1 18 9,4 54,0 150,0
12362 3G1 18 9,8 64,0 163,0 12427 3G1 18 9,8 64,0 163,0
12363 4G1 18 10,8 76,0 200,0 12428 4G1 18 10,8 76,0 200,0
12364 5G1 18 12,1 89,0 239,0 12429 5G1 18 12,1 89,0 239,0
12365 7G1 18 14,5 114,0 289,0 12430 7G1 18 14,5 114,0 289,0
12366 12 G 1 18 17,4 186,0 464,0 12431 12 G 1 18 17,4 186,0 464,0
12367 18 G 1 18 20,7 284,0 628,0 12432 18 G 1 18 20,7 284,0 628,0
12368 25 G 1 18 24,8 387,0 855,0 12433 25 G 1 18 24,8 387,0 855,0
12369 2 x 1,5 16 10,2 64,0 162,0 12434 2 x 1,5 16 10,2 64,0 162,0
12370 3 G 1,5 16 10,9 82,0 187,0 12435 3 G 1,5 16 10,9 82,0 187,0
12371 4 G 1,5 16 12,2 99,0 240,0 12436 4 G 1,5 16 12,2 99,0 240,0
Continuation
378
Cables according to international Approvals / PVC-Control Cables UL/CSA
379
Cables according to international Approvals / PVC-Control Cables UL/CSA
Application
USA NFPA 79 edition 2012 conformant flexible power cables up to 600 V, for all machinery in tool and plant constuction, suitable for installation in
dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation from the cable rack
to machines and industrial plants.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
69750 2x1 18 8,6 50,0 151,0 69780 4 G 2,5 14 11,4 148,0 341,0
69751 3G1 18 9,0 60,0 164,0 69781 5 G 2,5 14 12,4 181,0 420,0
69752 4G1 18 9,7 71,0 200,0 69782 7 G 2,5 14 15,3 255,0 551,0
69753 5G1 18 10,5 88,0 229,0 69783 8 G 2,5 14 16,5 285,0 583,0
69754 7G1 18 12,2 111,0 306,0 69784 9 G 2,5 14 16,5 309,0 593,0
69755 9G1 18 13,2 139,0 371,0 69785 10 G 2,5 14 17,9 340,0 631,0
69756 10 G 1 18 15,0 150,0 411,0 69786 12 G 2,5 14 18,4 441,0 847,0
69757 12 G 1 18 15,4 184,0 460,0 69787 18 G 2,5 14 22,4 570,0 1336,0
69758 18 G 1 18 17,8 260,0 624,0 69788 25 G 2,5 14 26,5 738,0 1921,0
69759 25 G 1 18 21,9 349,0 845,0 69789 3G4 12 11,6 174,0 381,0
69760 34 G 1 18 24,5 486,0 984,0 69790 4G4 12 12,6 230,0 504,0
69761 50 G 1 18 26,2 625,0 1096,0 69791 5G4 12 14,5 273,0 692,0
69762 2 x 1,5 16 9,0 63,0 161,0 69792 7G4 12 17,1 316,0 908,0
69763 3 G 1,5 16 9,4 80,0 181,0 69793 9G4 12 18,4 402,0 1104,0
69764 4 G 1,5 16 10,2 97,0 240,0 69794 12 G 4 12 20,5 507,0 1497,0
69765 5 G 1,5 16 11,1 119,0 274,0 69795 18 G 4 12 25,0 751,0 2104,0
69766 7 G 1,5 16 12,9 147,0 367,0 69796 3G6 10 13,8 240,0 623,0
69767 8 G 1,5 16 14,5 170,0 431,0 69797 4G6 10 15,1 305,0 729,0
69768 9 G 1,5 16 14,5 182,0 437,0 69798 5G6 10 16,4 439,0 1082,0
69769 10 G 1,5 16 15,8 193,0 511,0 69799 7G6 10 18,0 505,0 1414,0
69770 12 G 1,5 16 16,2 267,0 598,0 69800 3 G 10 8 17,6 350,0 1108,0
69771 16 G 1,5 16 17,9 315,0 630,0 69801 4 G 10 8 19,3 535,0 1324,0
69772 18 G 1,5 16 18,9 374,0 787,0 69802 5 G 10 8 22,1 592,0 1596,0
69773 25 G 1,5 16 22,3 526,0 1240,0 69803 7 G 10 8 24,2 810,0 2186,0
69774 34 G 1,5 16 24,9 629,0 1401,0
69775 41 G 1,5 16 26,7 801,0 2671,0
69776 50 G 1,5 16 33,7 885,0 3614,0
69777 61 G 1,5 16 36,0 1100,0 4089,0
69778 2 x 2,5 14 10,0 96,0 269,0
69779 3 G 2,5 14 10,5 144,0 294,0
380
Cables according to international Approvals / PVC-Control Cables UL/CSA
Application
USA NFPA 79 edition 2012 conformant flexible power cables up to 600 V, for all machinery in tool and plant constuction, suitable for installation in
dry, humid and damp environments, in the open and in pipes. For underground installation and for open, unprotected installation from the cable rack
to machines and industrial plants. N
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
69804 3 G 16 6 25,2 653,0 1385,0 69822 4 G 95 3/0 55,0 4060,0 10200,0
69805 4 G 16 6 27,8 807,0 1861,0 69823 5 G 95 3/0 60,5 5244,0 13800,0
69806 5 G 16 6 31,2 940,0 2614,0 69824 3 G 120 4/0 54,0 4176,0 11090,0
69807 7 G 16 6 34,5 1345,0 3211,0 69825 4 G 120 4/0 59,5 5231,0 13620,0
69808 3 G 25 4 29,0 920,0 2455,0 69826 5 G 120 4/0 64,5 6624,0 15420,0
69809 4 G 25 4 32,4 1169,0 2721,0
69810 5 G 25 4 34,2 1420,0 3490,0
69811 7 G 25 4 40,3 1921,0 4960,0
69812 3 G 35 2 32,4 1250,0 3130,0
69813 4 G 35 2 36,2 1680,0 4100,0
69814 5 G 35 2 40,5 2020,0 4921,0
69815 3 G 50 1 40,4 1887,0 4560,0
69816 4 G 50 1 45,5 2370,0 5761,0
69817 5 G 50 1 50,0 2880,0 7186,0
69818 3 G 70 2/0 47,1 2516,0 5580,0
69819 4 G 70 2/0 51,1 3257,0 7387,0
69820 5 G 70 2/0 56,0 4032,0 9290,0
69821 3 G 95 3/0 50,1 3086,0 8520,0
381
Cables according to international Approvals / PVC-Control Cables UL/CSA
Note
Advantages
TC-ER, Tray Cable Exposed Run
Simple installation
Outstanding flexibility
Application
USA NFPA 79 edition 2012 compliant, screened, flexible power cable to 600 V (WTTC 1000 V), for all tool and plant construction machinery, suitable
for installation in dry, damp and wet environments, outdoors and in pipes. For underground installation and for open, unprotected installtion from
the cable tray to the machine and industrial plants.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
63049 0,963 3 x 18 8,2 31,0 118,0 63064 2,08 5 x 14 11,6 139,0 264,0
63050 0,963 4 x 18 8,8 52,0 136,0 63065 2,08 7 x 14 12,5 185,0 325,0
63051 0,963 5 x 18 9,4 62,0 149,0 63066 2,08 12 x 14 16,9 309,0 591,0
63052 0,963 7 x 18 10,1 83,0 193,0 63067 2,08 18 x 14 19,5 448,0 780,0
63053 0,963 12 x 18 12,9 143,0 328,0 63068 2,08 25 x 14 23,3 632,0 1041,0
63054 0,963 18 x 18 15,7 207,0 431,0 63069 3,31 4 x 12 12,2 179,0 313,0
63055 0,963 25 x 18 17,7 284,0 569,0 63070 3,31 5 x 12 13,4 223,0 384,0
62997 1,31 3 x 16 8,9 57,0 144,0 63071 3,31 7 x 12 15,5 298,0 492,0
63056 1,31 4 x 16 9,6 72,0 172,0 63072 5,26 4 x 10 15,5 256,0 547,0
63057 1,31 5 x 16 10,3 84,0 186,0 63073 5,26 5 x 10 16,8 312,0 608,0
63058 1,31 7 x 16 11,3 124,0 243,0 63074 5,26 7 x 10 18,2 430,0 850,0
63059 1,31 12 x 16 15,1 199,0 421,0 63075 8,37 4 x 8 19,9 426,0 851,0
63060 1,31 18 x 16 17,3 290,0 510,0 63076 13,3 4 x 6 23,3 657,0 1197,0
63061 1,31 25 x 16 19,6 384,0 704,0 63077 21,2 4 x 4 28,6 1026,0 1970,0
63062 2,08 3 x 14 9,8 85,0 178,0 63078 33,6 4 x 2 33,2 1412,0 2874,0
63063 2,08 4 x 14 10,7 115,0 220,0
382
UL/CSA PUR/TPE CONTROL CABLES
Cables according to international Approvals / PUR-Control Cables UL/CSA
Application
UL and CSA approved flexible control cable rated at 600 V, primarily designed for exporters to the US or Canadian market. Used in machine tools,
control systems, connection between control panels and machines, assembly lines and other industrial equipment. Suitable for installation in dry,
moist, wet and outdoor environment and moderate flexing applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12471 2 x 0,5 20 5,8 9,6 52,0 12495 2 x 1,5 16 6,8 28,8 75,0
12472 3 G 0,5 20 6,2 14,0 64,0 12496 3 G 1,5 16 7,4 44,0 96,0
12473 4 G 0,5 20 6,6 19,0 72,0 12497 4 G 1,5 16 8,0 58,0 117,0
12474 5 G 0,5 20 7,2 24,0 88,0 12498 5 G 1,5 16 8,6 72,0 140,0
12475 7 G 0,5 20 8,4 34,0 130,0 12499 7 G 1,5 16 10,5 101,0 186,0
12476 8 G 0,5 20 9,5 38,4 145,0 12500 9 G 1,5 16 12,7 129,7 244,0
12477 9 G 0,5 20 10,3 43,2 180,0 12501 12 G 1,5 16 13,3 173,0 319,0
12478 12 G 0,5 20 10,8 58,0 196,0 12502 18 G 1,5 16 15,7 260,0 451,0
12479 18 G 0,5 20 12,8 86,0 260,0 12503 25 G 1,5 16 18,8 360,0 625,0
12480 25 G 0,5 20 15,4 120,0 368,0 12504 34 G 1,5 16 22,0 490,0 850,0
12481 34 G 0,5 20 17,6 163,0 502,0 12505 41 G 1,5 16 23,6 590,0 1041,0
12482 41 G 0,5 20 19,7 197,0 594,0 12506 2 x 2,5 14 8,1 48,0 115,0
12483 2x1 18 6,2 19,2 57,0 12507 3 G 2,5 14 8,6 72,0 143,0
12484 3G1 18 6,6 27,0 68,0 12508 4 G 2,5 14 10,0 96,0 185,0
12485 4G1 18 7,2 38,4 79,0 12509 5 G 2,5 14 10,8 120,0 221,0
12486 5G1 18 7,8 48,0 97,0 12510 7 G 2,5 14 13,0 168,0 293,0
12487 7G1 18 9,1 67,0 141,0 12511 9 G 2,5 14 15,5 216,0 429,0
12488 8G1 18 9,9 76,8 152,0 12512 12 G 2,5 14 16,6 288,0 563,0
12489 9G1 18 11,0 86,4 190,0 12513 18 G 2,5 14 19,5 432,0 854,0
12490 12 G 1 18 11,7 115,2 211,0 12514 19 G 2,5 14 19,5 456,0 914,0
12491 18 G 1 18 14,0 173,0 284,0 12515 25 G 2,5 14 23,8 600,0 1188,0
12492 25 G 1 18 17,0 240,0 394,0 12516 3G4 12 11,1 115,0 232,0
12493 34 G 1 18 19,2 326,0 521,0 12517 4G4 12 12,4 154,0 298,0
12494 41 G 1 18 21,0 394,0 609,0
Continuation
384
Cables according to international Approvals / PUR-Control Cables UL/CSA
385
Cables according to international Approvals / PUR-Control Cables UL/CSA
Application
For use on conveyor belts, tooling machines, conveyor system, production lines and automotive production plants. Also for medium mechanical stress
in flexible applications with free movement and without tensile stress. UL and CSA approved control cables espacially for U. S. and Canadian markets.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
JZ-602 PUR DC (blue core) JZ-602 PUR AC (red core)
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12805 3G1 18 6,6 27,0 68,0 12826 3G1 18 6,6 27,0 68,0
12806 4G1 18 7,2 38,0 79,0 12827 4G1 18 7,2 38,0 79,0
12807 5G1 18 7,8 48,0 97,0 12828 5G1 18 7,8 48,0 97,0
12808 7G1 18 9,1 67,0 141,0 12829 7G1 18 9,1 67,0 141,0
12809 12 G 1 18 11,7 115,0 211,0 12830 12 G 1 18 11,7 115,0 211,0
12810 18 G 1 18 14,0 173,0 284,0 12831 18 G 1 18 14,0 173,0 284,0
12811 25 G 1 18 17,0 240,0 394,0 12832 25 G 1 18 17,0 240,0 394,0
12812 3 G 1,5 16 7,4 44,0 96,0 12833 3 G 1,5 16 7,4 44,0 96,0
12813 4 G 1,5 16 8,0 58,0 117,0 12834 4 G 1,5 16 8,0 58,0 117,0
12814 5 G 1,5 16 8,6 72,0 140,0 12835 5 G 1,5 16 8,6 72,0 140,0
12815 7 G 1,5 16 10,5 101,0 186,0 12836 7 G 1,5 16 10,5 101,0 186,0
12816 12 G 1,5 16 13,3 173,0 319,0 12837 12 G 1,5 16 13,3 173,0 319,0
12817 18 G 1,5 16 15,7 260,0 451,0 12838 18 G 1,5 16 15,7 260,0 451,0
12818 25 G 1,5 16 18,8 360,0 625,0 12839 25 G 1,5 16 18,8 360,0 625,0
12819 3 G 2,5 14 8,6 72,0 143,0 12840 3 G 2,5 14 8,6 72,0 143,0
12820 4 G 2,5 14 10,0 96,0 185,0 12841 4 G 2,5 14 10,0 96,0 185,0
12821 5 G 2,5 14 10,8 120,0 221,0 12842 5 G 2,5 14 10,8 120,0 221,0
12822 7 G 2,5 14 13,0 168,0 293,0 12843 7 G 2,5 14 13,0 168,0 293,0
12823 12 G 2,5 14 16,6 288,0 563,0 12844 12 G 2,5 14 16,6 288,0 563,0
12824 18 G 2,5 14 19,5 432,0 854,0 12845 18 G 2,5 14 19,5 432,0 854,0
12825 25 G 2,5 14 23,8 600,0 1188,0 12846 25 G 2,5 14 23,8 600,0 1188,0
386
Cables according to international Approvals / PUR-Control Cables UL/CSA
Application
Extremely robust, control cable resistant to mineral oils and to coolant emulsions. In tool machinery, conveyor belts and production lines, for plant
installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses
with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside. Interesting for the export-oriented
machinery plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
N
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
28240 2 x 0,5 20 6,9 9,6 60,0 28305 2 x 0,5 20 6,9 9,6 60,0
28241 3 G 0,5 20 7,3 14,4 70,0 28306 3 G 0,5 20 7,3 14,4 70,0
28242 4 G 0,5 20 7,9 19,0 104,0 28307 4 G 0,5 20 7,9 19,0 104,0
28243 5 G 0,5 20 8,5 24,0 120,0 28308 5 G 0,5 20 8,5 24,0 120,0
28244 7 G 0,5 20 9,9 33,6 141,0 28309 7 G 0,5 20 9,9 33,6 141,0
28245 12 G 0,5 20 12,2 58,0 208,0 28310 12 G 0,5 20 12,2 58,0 208,0
28246 18 G 0,5 20 14,4 86,0 289,0 28311 18 G 0,5 20 14,4 86,0 289,0
28247 25 G 0,5 20 17,2 120,0 342,0 28312 25 G 0,5 20 17,2 120,0 342,0
28248 2 x 0,75 19 7,3 14,4 70,0 28313 2 x 0,75 19 7,3 14,4 70,0
28249 3 G 0,75 19 7,7 21,6 78,0 28314 3 G 0,75 19 7,7 21,6 78,0
28250 4 G 0,75 19 8,3 29,0 134,0 28315 4 G 0,75 19 8,3 29,0 134,0
28251 5 G 0,75 19 9,1 36,0 149,0 28316 5 G 0,75 19 9,1 36,0 149,0
28252 7 G 0,75 19 10,7 50,0 201,0 28317 7 G 0,75 19 10,7 50,0 201,0
28253 12 G 0,75 19 13,1 86,0 269,0 28318 12 G 0,75 19 13,1 86,0 269,0
28254 18 G 0,75 19 15,6 130,0 378,0 28319 18 G 0,75 19 15,6 130,0 378,0
28255 25 G 0,75 19 18,9 180,0 498,0 28320 25 G 0,75 19 18,9 180,0 498,0
28256 2x1 18 7,9 19,2 86,0 28321 2x1 18 7,9 19,2 86,0
28257 3G1 18 8,3 29,0 100,0 28322 3G1 18 8,3 29,0 100,0
28258 4G1 18 9,1 38,4 107,0 28323 4G1 18 9,1 38,4 107,0
28259 5G1 18 9,9 48,0 130,0 28324 5G1 18 9,9 48,0 130,0
28260 7G1 18 11,7 67,0 174,0 28325 7G1 18 11,7 67,0 174,0
28261 12 G 1 18 14,5 115,0 290,0 28326 12 G 1 18 14,5 115,0 290,0
28262 18 G 1 18 17,3 173,0 405,0 28327 18 G 1 18 17,3 173,0 405,0
28263 25 G 1 18 21,1 240,0 570,0 28328 25 G 1 18 21,1 240,0 570,0
28264 2 x 1,5 16 8,7 29,0 97,0 28329 2 x 1,5 16 8,7 29,0 97,0
28265 3 G 1,5 16 9,2 43,0 118,0 28330 3 G 1,5 16 9,2 43,0 118,0
28266 4 G 1,5 16 10,0 58,0 141,0 28331 4 G 1,5 16 10,0 58,0 141,0
28267 5 G 1,5 16 11,0 72,0 181,0 28332 5 G 1,5 16 11,0 72,0 181,0
28268 7 G 1,5 16 13,3 101,0 234,0 28333 7 G 1,5 16 13,3 101,0 234,0
28269 12 G 1,5 16 16,6 173,0 370,0 28334 12 G 1,5 16 16,6 173,0 370,0
28270 18 G 1,5 16 19,7 259,0 520,0 28335 18 G 1,5 16 19,7 259,0 520,0
28271 25 G 1,5 16 23,9 360,0 730,0 28336 25 G 1,5 16 23,9 360,0 730,0
Continuation
387
Cables according to international Approvals / PUR-Control Cables UL/CSA
388
Cables according to international Approvals / PUR-Control Cables UL/CSA
Application
UL and CSA approved flexible control cables up to 600 V, for all machinery in tooling and plant construction, suitable for installation in dry, moist,
wet and outdoor environments for medium mechanical loads. Designed for the export-orientated machinery manufacturer, specifically for USA and
Canada.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
N
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12550 2 x 0,5 20 7,7 41,0 93,0 12586 5 G 2,5 14 13,2 220,0 329,0
12551 3 G 0,5 20 8,0 45,0 124,0 12587 7 G 2,5 14 15,6 284,0 428,0
12552 4 G 0,5 20 8,6 54,0 133,0 12588 9 G 2,5 14 18,1 349,0 580,0
12553 5 G 0,5 20 9,2 66,0 153,0 12589 12 G 2,5 14 19,2 470,0 761,0
12554 7 G 0,5 20 10,5 79,0 191,0 12590 18 G 2,5 14 23,0 572,0 1140,0
12555 9 G 0,5 20 12,3 94,0 243,0 12591 25 G 2,5 14 28,3 740,0 1551,0
12556 12 G 0,5 20 13,0 137,0 322,0 12592 2x4 12 12,5 124,0 209,0
12557 18 G 0,5 20 15,6 156,0 374,0 12593 3G4 12 13,1 178,0 310,0
12558 25 G 0,5 20 18,2 250,0 436,0 12594 4G4 12 14,5 234,0 456,0
12559 34 G 0,5 20 20,1 316,0 560,0 12595 5G4 12 15,8 284,0 532,0
12560 41 G 0,5 20 22,4 348,0 663,0 12596 7G4 12 19,0 321,0 737,0
12561 2x1 18 8,1 54,0 107,0 12597 2x6 10 14,2 176,0 318,0
12562 3G1 18 8,4 64,0 130,0 12598 3G6 10 15,2 245,0 411,0
12563 4G1 18 9,1 76,0 155,0 12599 4G6 10 16,6 316,0 572,0
12564 5G1 18 10,0 89,0 181,0 12600 5G6 10 18,4 442,0 732,0
12565 7G1 18 11,3 114,0 209,0 12601 7G6 10 22,2 530,0 961,0
12566 9G1 18 13,3 144,0 321,0 12602 3 G 10 8 19,1 367,0 741,0
12567 12 G 1 18 13,8 186,0 341,0 12603 4 G 10 8 21,1 549,0 988,0
12568 18 G 1 18 16,2 284,0 473,0 12604 5 G 10 8 23,7 604,0 1202,0
12569 25 G 1 18 19,5 387,0 650,0 12605 7 G 10 8 26,5 820,0 1743,0
12570 34 G 1 18 22,5 500,0 781,0 12606 3 G 16 6 24,2 653,0 1088,0
12571 41 G 1 18 24,2 578,0 892,0 12607 4 G 16 6 27,2 807,0 1662,0
12572 2 x 1,5 16 8,7 64,0 136,0 12608 5 G 16 6 30,6 940,0 2021,0
12573 3 G 1,5 16 9,2 82,0 165,0 12609 7 G 16 6 33,6 1345,0 2720,0
12574 4 G 1,5 16 10,0 99,0 192,0 12610 3 G 25 4 30,2 920,0 1947,0
12575 5 G 1,5 16 10,8 123,0 224,0 12611 4 G 25 4 33,3 1169,0 2591,0
12576 7 G 1,5 16 12,9 148,0 273,0 12612 5 G 25 4 36,8 1420,0 3197,0
12577 9 G 1,5 16 14,8 187,0 340,0 12613 7 G 25 4 40,6 1921,0 4530,0
12578 12 G 1,5 16 15,6 274,0 461,0 12614 3 G 35 2 33,8 1250,0 2701,0
12579 18 G 1,5 16 18,3 386,0 674,0 12615 4 G 35 2 37,7 1680,0 3277,0
12580 25 G 1,5 16 22,5 531,0 950,0 12616 5 G 35 2 41,5 2020,0 4530,0
12581 34 G 1,5 16 25,1 671,0 1203,0 12617 4 G 50 1 40,5 2370,0 3370,0
12582 41 G 1,5 16 27,3 840,0 1588,0 12618 4 G 70 2/0 46,1 3257,0 4630,0
12583 2 x 2,5 14 10,3 110,0 173,0 12619 4 G 95 3/0 50,7 4060,0 6114,0
12584 3 G 2,5 14 10,8 148,0 220,0 12620 4 G 120 4/0 57,0 5231,0 7417,0
12585 4 G 2,5 14 11,8 169,0 270,0
389
Cables according to international Approvals / PUR-Control Cables UL/CSA
Application
Extremely robust sheated cable, used in machinery, tools and plant, in rolling and steel mills at particularly critical poinst. For medium mechanical
stress for flexible use with free movement without tensile stress or forced movements in dry, damp and wet rooms and outdoors. Through the good
flexibility quickly and safely to install. Designed for the export-oriented engineering.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath cross-sec. app. mm weight app. Sheath cross-sec. app. mm weight app.
colour mm kg / km kg / km colour mm kg / km kg / km
black grey
28370 2 x 0,5 20 9,0 41,0 131,0 28430 2 x 0,5 20 9,0 41,0 131,0
28371 3 G 0,5 20 9,3 45,0 154,0 28431 3 G 0,5 20 9,3 45,0 154,0
28372 4 G 0,5 20 9,9 54,0 176,0 28432 4 G 0,5 20 9,9 54,0 176,0
28373 5 G 0,5 20 10,6 66,0 204,0 28433 5 G 0,5 20 10,6 66,0 204,0
28374 7 G 0,5 20 12,2 79,0 237,0 28434 7 G 0,5 20 12,2 79,0 237,0
28375 12 G 0,5 20 14,7 137,0 323,0 28435 12 G 0,5 20 14,7 137,0 323,0
28376 18 G 0,5 20 17,3 156,0 431,0 28436 18 G 0,5 20 17,3 156,0 431,0
28377 25 G 0,5 20 20,6 250,0 507,0 28437 25 G 0,5 20 20,6 250,0 507,0
28378 2 x 0,75 19 9,4 46,0 143,0 28438 2 x 0,75 19 9,4 46,0 143,0
28379 3 G 0,75 19 9,8 57,0 158,0 28439 3 G 0,75 19 9,8 57,0 158,0
28380 4 G 0,75 19 10,4 63,0 193,0 28440 4 G 0,75 19 10,4 63,0 193,0
28381 5 G 0,75 19 11,1 76,0 231,0 28441 5 G 0,75 19 11,1 76,0 231,0
28382 7 G 0,75 19 13,0 100,0 337,0 28442 7 G 0,75 19 13,0 100,0 337,0
28383 12 G 0,75 19 15,8 175,0 424,0 28443 12 G 0,75 19 15,8 175,0 424,0
28384 18 G 0,75 19 17,9 240,0 568,0 28444 18 G 0,75 19 17,9 240,0 568,0
28385 25 G 0,75 19 22,8 306,0 741,0 28445 25 G 0,75 19 22,8 306,0 741,0
28386 2x1 18 9,9 54,0 158,0 28446 2x1 18 9,9 54,0 158,0
28387 3G1 18 10,3 64,0 169,0 28447 3G1 18 10,3 64,0 169,0
28388 4G1 18 11,1 76,0 207,0 28448 4G1 18 11,1 76,0 207,0
28389 5G1 18 12,2 89,0 244,0 28449 5G1 18 12,2 89,0 244,0
28390 7G1 18 14,5 114,0 292,0 28450 7G1 18 14,5 114,0 292,0
28391 12 G 1 18 17,4 186,0 472,0 28451 12 G 1 18 17,4 186,0 472,0
28392 18 G 1 18 20,7 284,0 634,0 28452 18 G 1 18 20,7 284,0 634,0
28393 25 G 1 18 24,8 387,0 861,0 28453 25 G 1 18 24,8 387,0 861,0
Continuation
390
Cables according to international Approvals / PUR-Control Cables UL/CSA
391
Cables according to international Approvals / PUR/TPE-Control Cables UL/CSA
Application
HELUKABEL TRAYCONTROL 670 HDP / 670-C-HDP are multi-conductor severe duty motor supply cables with Bus Drop, TC-ER and CIC/TC
approval. Superior oil performance for long cable life and permitted to be used in hazardous (classified) locations Class I Div 2 per NEC 336, 318 and
501. Special extruded sheath and fine copper stranding approved for exposed run, pipes and burial installation. Excellent flexibility and easier to pull
than standard tray cables. Suitable for installation in the open unprotected installation on cable tray and from cable tray to machines according to
NFPA 79 edition 2012.
Recommended Applications: Motor connections in industrial and automation environments, machine tool, automotive and renewable energies.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TRAYCONTROL 670 HDP TRAYCONTROL 670-C HDP
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
66820 4x1 18 8,4 39,0 103,0 66829 4x1 18 9,8 52,0 133,0
66821 4 G 1,32 16 9,2 51,0 133,0 66830 4 G 1,32 16 10,5 72,0 159,0
66822 4 G 2,08 14 10,0 80,0 170,0 66831 4 G 2,08 14 11,7 115,0 222,0
66823 4 G 3,31 12 11,2 127,0 229,0 66832 4 G 3,31 12 12,8 179,0 283,0
66824 4G6 10 15,2 230,0 393,0 66833 4G6 10 16,9 256,0 460,0
66825 4 G 10 8 19,3 384,0 626,0 66834 4 G 10 8 22,1 426,0 741,0
66826 4 G 16 6 22,4 614,0 885,0 66835 4 G 16 6 26,2 657,0 1059,0
66827 4 G 25 4 26,7 960,0 1301,0 66836 4 G 25 4 30,8 1026,0 1497,0
66828 4 G 35 2 31,5 1344,0 1983,0 66837 4 G 35 2 35,0 1412,0 2058,0
392
UL/CSA HALOGEN-FREE CONTROL CABLES
Cables according to international Approvals / Halogen-free Control Cables UL/CSA
Application
For fixed installation or flexible application, with free movements without forcing which do not constantly recur and without tensile stress, for high
mechanical strain. As a measuring and control cable primarily in machinery and plant construction, in air-conditoning systems, at the warehouse and
conveyor systems, in ship-building and in the renewable energies such as in the construction of wind power stations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
13344 2 x 0,5 20 5,0 9,6 43,0 13352 8 G 0,5 20 8,0 38,0 101,0
13345 3 G 0,5 20 5,3 14,4 50,0 13353 10 G 0,5 20 8,8 48,0 121,0
13346 3 x 0,5 20 5,3 14,4 50,0 13354 12 G 0,5 20 9,1 58,0 142,0
13347 4 G 0,5 20 5,7 19,0 60,0 13355 16 G 0,5 20 10,0 76,0 183,0
13348 4 x 0,5 20 5,7 19,0 60,0 13356 18 G 0,5 20 10,7 86,0 204,0
13349 5 G 0,5 20 6,2 24,0 71,0 13357 20 G 0,5 20 11,2 96,0 227,0
13350 5 x 0,5 20 6,2 24,0 71,0 13359 25 G 0,5 20 12,7 120,0 283,0
13351 7 G 0,5 20 7,4 33,6 84,0 13360 30 G 0,5 20 13,5 144,0 324,0
Continuation
394
Cables according to international Approvals / Halogen-free Control Cables UL/CSA
395
Cables according to international Approvals / Halogen-free Control Cables UL/CSA
Note
G = with green-yellow conductor
x = without green-yellow conductor
screened analogue type:
MEGAFLEX 600-C, confer page 400
Application
For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile
stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate
engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
13200 2 x 0,5 20 6,4 9,6 56,0 13208 8 G 0,5 20 10,7 38,0 150,0
13201 3 G 0,5 20 6,8 14,4 68,0 13209 10 G 0,5 20 11,6 48,0 176,0
13202 3 x 0,5 20 6,8 14,4 68,0 13210 12 G 0,5 20 12,2 58,0 200,0
13203 4 G 0,5 20 7,6 19,0 100,0 13211 16 G 0,5 20 13,7 76,0 250,0
13204 4 x 0,5 20 7,6 19,0 100,0 13212 18 G 0,5 20 14,4 86,0 276,0
13205 5 G 0,5 20 8,2 24,0 117,0 13213 20 G 0,5 20 15,3 96,0 293,0
13206 5 x 0,5 20 8,2 24,0 117,0 13214 25 G 0,5 20 17,2 120,0 335,0
13207 7 G 0,5 20 9,8 33,6 138,0 13215 30 G 0,5 20 18,0 144,0 348,0
Continuation
396
Cables according to international Approvals / Halogen-free Control Cables UL/CSA
397
Cables according to international Approvals / Halogen-free Control Cables UL/CSA
Application
For fixed installation or flexible application that does not permanently recurring free movement without forced motion and without tensile stress, for
high mechanical strain. As a measuring and control cable e. g. in machine and plant engineering, air conditioning in the warehouse and materials
handling, shipbuilding and in the newable energies such as wind power stations.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
13500 2 x 0,5 20 5,7 35,0 46,0 13508 8 G 0,5 20 8,5 80,0 116,0
13501 3 G 0,5 20 6,0 42,0 56,0 13509 10 G 0,5 20 9,3 94,0 135,0
13502 3 x 0,5 20 6,0 42,0 56,0 13510 12 G 0,5 20 9,6 108,0 158,0
13503 4 G 0,5 20 6,5 47,0 62,0 13511 16 G 0,5 20 10,7 129,0 210,0
13504 4 x 0,5 20 6,5 47,0 62,0 13512 18 G 0,5 20 11,2 145,0 216,0
13505 5 G 0,5 20 7,0 56,0 75,0 13514 20 G 0,5 20 11,9 172,0 240,0
13506 5 x 0,5 20 7,0 56,0 75,0 13515 25 G 0,5 20 13,4 240,0 315,0
13507 7 G 0,5 20 7,9 69,0 98,0
Continuation
398
Cables according to international Approvals / Halogen-free Control Cables UL/CSA
399
Cables according to international Approvals / Halogen-free Control Cables UL/CSA
Note
G = with green-yellow conductor
x = without green-yellow conductor
unscreened analogue type:
MEGAFLEX 600, confer page 396
Application
For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motionand without tensile stress,
for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate
engineering,in foundries and steel mills. Especially suited for wind power plant and computer equipment.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
15217 2 x 0,5 20 6,9 35,0 46,0 15225 10 G 0,5 20 12,1 94,0 135,0
15218 3 G 0,5 20 7,3 42,0 56,0 15226 12 G 0,5 20 12,7 108,0 158,0
15219 3 x 0,5 20 7,3 42,0 56,0 15227 18 G 0,5 20 14,9 145,0 216,0
15220 4 G 0,5 20 8,1 47,0 62,0 15228 20 G 0,5 20 15,8 172,0 240,0
15221 4 x 0,5 20 8,1 47,0 62,0 15229 25 G 0,5 20 17,7 240,0 315,0
15222 5 G 0,5 20 8,7 56,0 75,0 15230 2 x 0,75 18 7,3 40,0 60,0
15223 5 x 0,5 20 8,7 56,0 75,0 15231 3 G 0,75 18 7,7 52,0 68,0
15224 7 G 0,5 20 10,3 69,0 98,0 15232 3 x 0,75 18 7,7 52,0 68,0
Continuation
400
Cables according to international Approvals / Halogen-free Control Cables UL/CSA
401
UL/CSA DATA CABLES
402
Cables according to international Approvals / Data Cables UL/CSA
Application
As a flexible connector and connecting cable, as control, signal and measuring line of machine tools, conveyor belts and plant construction, air
conditioning systems, in foundries and steel mills.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Part no. No.cores x AWG-No. Outer Cop. Weight Part no. Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath
colour
grey
Sheath
colour
black
cross-sec.
mm
app.
mm
weight app.
kg / km kg / km
Sheath
colour
grey
Sheath
colour
black
cross-sec.
mm
app.
mm
weight app.
kg / km kg / km N
83137 83045 2 x 0,14 26 3,6 3,6 13,0 83188 83389 6 x 0,56 20 6,1 29,0 65,0
83138 83046 3 x 0,14 26 3,8 4,0 15,0 83189 83390 10 x 0,56 20 7,6 48,2 102,0
83139 83047 4 x 0,14 26 4,0 5,4 18,0 83190 83391 12 x 0,56 20 7,8 58,2 120,0
83140 83048 6 x 0,14 26 4,6 8,1 25,0 83191 83392 16 x 0,56 20 8,7 77,3 152,0
83141 83049 10 x 0,14 26 5,6 13,4 38,0 83192 83393 18 x 0,56 20 9,3 87,0 168,0
83142 83050 12 x 0,14 26 5,8 16,2 46,0 83193 83394 24 x 0,56 20 10,9 116,3 224,0
83143 83055 16 x 0,14 26 6,3 21,5 56,0 83194 83395 27 x 0,56 20 11,2 129,8 260,0
83144 83056 18 x 0,14 26 6,6 34,4 62,0 83195 83396 30 x 0,56 20 11,8 144,6 300,0
83145 83057 24 x 0,14 26 7,5 32,4 82,0 83201 83397 2 x 0,82 18 6,1 15,2 50,0
83146 83058 27 x 0,14 26 7,6 36,3 97,0 83202 83398 3 x 0,82 18 6,4 23,2 62,0
83147 83059 30 x 0,14 26 8,0 40,4 110,0 83203 83399 4 x 0,82 18 6,9 31,3 72,0
83153 83130 2 x 0,23 24 3,8 4,6 16,0 83204 83474 6 x 0,82 18 8,1 47,0 100,0
83154 83131 3 x 0,23 24 4,0 7,1 19,0 83205 83475 10 x 0,82 18 10,4 78,2 180,0
83155 83132 4 x 0,23 24 4,3 9,4 23,0 83206 83476 12 x 0,82 18 10,9 94,0 182,0
83156 83133 6 x 0,23 24 4,9 14,2 32,0 83207 83477 16 x 0,82 18 12,2 125,1 240,0
83157 83134 10 x 0,23 24 6,0 23,8 55,0 83208 83478 18 x 0,82 18 13,0 141,1 270,0
83158 83135 12 x 0,23 24 6,2 28,5 60,0 83209 83479 24 x 0,82 18 15,2 188,2 370,0
83159 83136 16 x 0,23 24 6,8 38,1 75,0 83210 83480 27 x 0,82 18 15,8 212,0 400,0
83160 83371 18 x 0,23 24 7,1 43,1 82,0 83211 83481 30 x 0,82 18 16,3 235,6 470,0
83161 83372 24 x 0,23 24 8,1 59,7 116,0 83217 83482 2 x 1,3 16 6,6 24,4 70,0
83162 83373 27 x 0,23 24 8,4 64,7 140,0 83218 83483 3 x 1,3 16 7,0 37,1 90,0
83163 83374 30 x 0,23 24 8,9 71,9 150,0 83219 83484 4 x 1,3 16 7,6 49,4 110,0
83169 83375 2 x 0,34 22 4,1 6,5 25,0 83220 83491 6 x 1,3 16 9,2 74,2 160,0
83170 83376 3 x 0,34 22 4,3 9,8 30,0 83221 83492 10 x 1,3 16 11,8 124,0 250,0
83171 83377 4 x 0,34 22 4,6 13,0 45,0 83222 83493 12 x 1,3 16 12,2 149,0 300,0
83172 83378 6 x 0,34 22 5,4 19,6 60,0 83223 83494 16 x 1,3 16 13,7 198,7 400,0
83173 83379 10 x 0,34 22 6,6 32,5 80,0 83224 83495 18 x 1,3 16 14,6 224,0 450,0
83174 83380 12 x 0,34 22 6,8 39,1 105,0 83225 83496 24 x 1,3 16 17,0 298,4 650,0
83175 83381 16 x 0,34 22 7,5 52,0 130,0 83226 83497 27 x 1,3 16 17,6 336,0 680,0
83176 83382 18 x 0,34 22 8,1 59,0 140,0 83227 83498 30 x 1,3 16 18,6 373,6 750,0
83177 83383 24 x 0,34 22 9,4 79,0 190,0
83178 83384 27 x 0,34 22 9,7 88,0 207,0
83179 83385 30 x 0,34 22 10,2 97,8 225,0
83185 83386 2 x 0,56 20 4,6 9,8 30,0
83186 83387 3 x 0,56 20 4,8 14,6 33,0
83187 83388 4 x 0,56 20 5,2 19,4 41,0
403
Cables according to international Approvals / Data Cables UL/CSA
Application
As a flexible connector and connecting cable, as control, signal and measuring line of machine tools, conveyor belts and plant construction, air
conditioning systems, in foundries and steel mills.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Part no. No.cores x AWG-No. Outer Cop. Weight Part no. Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath Sheath cross-sec. app. weight app. Sheath Sheath cross-sec. app. weight app.
colour colour mm mm kg / km kg / km colour colour mm mm kg / km kg / km
grey black grey black
83233 83624 2 x 2,08 14 8,4 39,6 120,0 83245 83636 2 x 3,2 12 9,3 61,0 150,0
83234 83625 3 x 2,08 14 8,9 59,6 150,0 83246 83637 3 x 3,2 12 9,8 91,4 210,0
83235 83626 4 x 2,08 14 9,6 79,2 190,0 83247 83638 4 x 3,2 12 10,8 121,6 300,0
83236 83627 6 x 2,08 14 11,4 119,0 300,0 83248 83639 6 x 3,2 12 12,8 183,7 430,0
83237 83628 10 x 2,08 14 15,1 198,4 450,0 83249 83640 10 x 3,2 12 17,0 305,9 500,0
83238 83629 12 x 2,08 14 15,6 238,7 500,0 83250 83641 12 x 3,2 12 17,5 367,6 700,0
83239 83630 16 x 2,08 14 17,2 319,0 700,0 83251 83642 16 x 3,2 12 19,8 490,9 810,0
83240 83631 18 x 2,08 14 18,3 358,4 750,0 83252 83643 18 x 3,2 12 21,0 551,7 970,0
83241 83632 24 x 2,08 14 21,5 478,4 900,0 83253 83644 24 x 3,2 12 24,8 736,4 1200,0
83242 83633 27 x 2,08 14 22,7 538,1 1100,0
83243 83634 30 x 2,08 14 23,5 598,4 1150,0
83244 83635 36 x 2,08 14 25,4 717,2 1800,0
404
Cables according to international Approvals / Data Cables UL/CSA
Note
Advantages
highly-flexible easy to install
Oil-resistant to OIL RES I & II
Available on request
PUR or TPE outer sheath
Sheath colour to suit customer
requirements
Application
HELUKABEL TRAYCONTROL 300 is a multi-core PVC data and control cable. Cross-sections with PLTC-ER and ITC-ER approval suitable for open,
unprotected installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as connecting and
joining cables and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates installation inside and
outside of machines and switch cabinets. Applications: tool machines, control panels, control and instrumentation technology, production automation, N
cable ducts, renewable energies.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62625 0,093 2 x 28 3,9 1,8 12,0 62655 0,241 15 x 24 7,4 34,7 69,0
62626 0,093 3 x 28 4,2 2,7 18,0 62656 0,241 20 x 24 8,4 46,3 86,0
62627 0,093 4 x 28 4,4 3,6 21,0 62657 0,241 25 x 24 9,3 57,9 103,0
62628 0,093 6 x 28 4,9 5,4 27,0 62658 0,241 30 x 24 9,6 69,4 131,0
62629 0,093 8 x 28 5,2 7,2 30,0 62659 0,241 40 x 24 11,2 92,6 173,0
62630 0,093 10 x 28 5,8 8,9 30,0 62660 0,241 50 x 24 12,4 115,7 219,0
62631 0,093 15 x 28 6,4 13,4 43,0 62661 0,382 2 x 22 6,1 7,4 22,0
62632 0,093 20 x 28 7,0 17,9 54,0 62662 0,382 3 x 22 6,7 11,0 28,0
62633 0,093 25 x 28 8,0 22,3 63,0 62663 0,382 4 x 22 7,2 14,7 32,0
62634 0,093 30 x 28 8,4 26,8 73,0 62664 0,382 6 x 22 7,8 22,0 46,0
62635 0,093 40 x 28 9,1 35,7 89,0 62665 0,382 8 x 22 8,8 29,4 54,0
62636 0,093 50 x 28 10,1 44,7 109,0 62666 0,382 10 x 22 9,1 36,7 66,0
62637 0,154 2 x 26 4,2 3,0 18,0 62667 0,382 15 x 22 9,7 55,0 90,0
62638 0,154 3 x 26 4,3 4,4 21,0 62668 0,382 20 x 22 10,5 73,4 115,0
62639 0,154 4 x 26 4,5 5,9 24,0 62669 0,382 25 x 22 11,9 91,7 141,0
62640 0,154 6 x 26 5,2 8,9 30,0 62670 0,382 30 x 22 12,3 110,0 176,0
62641 0,154 8 x 26 5,5 11,8 34,0 62671 0,382 40 x 22 13,5 146,7 234,0
62642 0,154 10 x 26 6,2 14,8 42,0 62672 0,382 50 x 22 14,9 183,4 293,0
62643 0,154 15 x 26 6,8 22,2 52,0 62673 0,616 2 x 20 6,9 11,9 57,0
62644 0,154 20 x 26 7,7 29,6 67,0 62674 0,616 3 x 20 7,2 17,8 60,0
62645 0,154 25 x 26 8,5 37,0 80,0 62675 0,616 4 x 20 7,8 23,7 73,0
62646 0,154 30 x 26 8,8 44,4 92,0 62676 0,616 6 x 20 9,0 35,5 97,0
62647 0,154 40 x 26 9,6 59,1 116,0 62677 0,616 8 x 20 9,6 47,4 133,0
62648 0,154 50 x 26 10,8 73,9 145,0 62678 0,616 10 x 20 10,8 59,2 143,0
62649 0,241 2 x 24 4,4 4,7 19,0 62679 0,616 15 x 20 12,4 88,8 177,0
62650 0,241 3 x 24 4,6 7,0 22,0 62680 0,616 20 x 20 14,5 118,3 261,0
62651 0,241 4 x 24 4,9 9,3 27,0 62681 0,616 25 x 20 15,3 147,9 353,0
62652 0,241 6 x 24 5,6 13,9 33,0 62682 0,616 30 x 20 15,9 177,5 419,0
62653 0,241 8 x 24 5,9 18,5 42,0 62683 0,616 40 x 20 18,1 236,6 562,0
62654 0,241 10 x 24 6,6 23,2 49,0 62684 0,616 50 x 20 20,1 295,7 699,0
Continuation
405
Cables according to international Approvals / Data Cables UL/CSA
406
Cables according to international Approvals / Data Cables UL/CSA
Application
Twisted pair control cable for use in tool making machinery conveyor system and production lines, in industrial plants and in air conditioning as well
as in the steel producing industries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
407
Cables according to international Approvals / Data Cables UL/CSA
408
Cables according to international Approvals / Data Cables UL/CSA
Application
HELUKABEL TRAYCONTROL 300 TP is a twisteded pair data and control cable. Cross-sections with PLTC-ER and ITC-ER approval for open, unprotected
installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as connecting and joining cables
and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates installation inside and outside of machines
and switch cabinets. Applications: tool machines, control panels, measuring devices, production automation, cable ducts, renewable energies.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
N
Part no. Cross- No.pairs x Outer Cop. Weight Part no. Cross- No.pairs x Outer Cop. Weight
section mm No.cores app. mm weight app. section mm No.cores app. mm weight app.
x kg / km kg / km x kg / km kg / km
AWG-no. AWG-no.
62794 0,154 1 x 2 x 26 3,6 3,0 20,0 61951 0,241 16 x 2 x 24 12,1 79,0 185,0
62795 0,154 2 x 2 x 26 5,1 5,0 24,0 61952 0,241 18 x 2 x 24 13,5 89,0 209,0
62796 0,154 3 x 2 x 26 5,3 8,0 30,0 61953 0,241 20 x 2 x 24 14,4 98,0 230,0
62797 0,154 4 x 2 x 26 5,8 11,0 38,0 61954 0,241 22 x 2 x 24 15,3 109,0 248,0
62798 0,154 5 x 2 x 26 6,2 14,0 44,0 61955 0,241 24 x 2 x 24 16,1 118,0 279,0
62799 0,154 6 x 2 x 26 6,8 16,0 51,0 61956 0,241 25 x 2 x 24 16,7 124,0 292,0
62800 0,154 7 x 2 x 26 6,9 19,0 57,0 61957 0,382 1 x 2 x 22 4,2 7,0 38,0
61928 0,154 8 x 2 x 26 7,3 22,0 64,0 61958 0,382 2 x 2 x 22 6,4 13,0 44,0
61929 0,154 10 x 2 x 26 7,4 27,0 76,0 61959 0,382 3 x 2 x 22 6,8 20,0 60,0
61930 0,154 12 x 2 x 26 9,1 33,0 93,0 61960 0,382 4 x 2 x 22 9,2 29,3 79,0
61931 0,154 14 x 2 x 26 9,8 38,0 103,0 61961 0,382 5 x 2 x 22 8,2 33,0 92,0
61932 0,154 15 x 2 x 26 10,6 41,0 109,0 61962 0,382 6 x 2 x 22 8,9 39,0 119,0
61933 0,154 16 x 2 x 26 10,7 43,0 112,0 61963 0,382 7 x 2 x 22 9,0 46,0 128,0
61934 0,154 18 x 2 x 26 11,1 49,0 119,0 61964 0,382 8 x 2 x 22 9,9 52,0 139,0
61935 0,154 20 x 2 x 26 11,9 54,0 130,0 61965 0,382 10 x 2 x 22 11,7 65,0 171,0
61936 0,154 22 x 2 x 26 12,4 59,0 150,0 61966 0,382 12 x 2 x 22 12,4 78,0 194,0
61937 0,154 24 x 2 x 26 13,1 65,0 169,0 61967 0,382 14 x 2 x 22 13,0 92,0 222,0
61938 0,154 25 x 2 x 26 13,4 67,0 178,0 61968 0,382 15 x 2 x 22 13,2 98,0 231,0
61939 0,241 1 x 2 x 24 3,9 5,0 32,0 61969 0,382 16 x 2 x 22 13,3 105,0 240,0
61940 0,241 2 x 2 x 24 5,9 10,0 36,0 61970 0,382 18 x 2 x 22 14,2 118,0 264,0
61941 0,241 3 x 2 x 24 6,2 15,0 48,0 61971 0,382 20 x 2 x 22 15,1 131,0 291,0
61942 0,241 4 x 2 x 24 6,5 20,0 56,0 61972 0,382 22 x 2 x 22 15,8 144,0 300,0
61943 0,241 5 x 2 x 24 7,2 25,0 71,0 61973 0,382 24 x 2 x 22 17,0 157,0 359,0
61944 0,241 6 x 2 x 24 8,1 29,0 80,0 61974 0,382 25 x 2 x 22 17,5 163,0 381,0
61945 0,241 7 x 2 x 24 8,2 34,0 89,0 61975 0,616 1 x 2 x 20 5,2 11,0 60,0
61946 0,241 8 x 2 x 24 8,9 39,0 98,0 61976 0,616 2 x 2 x 20 8,8 22,0 80,0
61947 0,241 10 x 2 x 24 10,5 49,0 111,0 61977 0,616 3 x 2 x 20 9,3 32,0 94,0
61948 0,241 12 x 2 x 26 11,0 59,0 135,0 61978 0,616 4 x 2 x 20 10,2 43,0 104,0
61949 0,241 14 x 2 x 24 11,6 69,0 160,0 61979 0,616 5 x 2 x 20 11,3 54,0 130,0
61950 0,241 15 x 2 x 24 12,0 74,0 171,0 61980 0,616 6 x 2 x 20 12,5 65,0 151,0
Continuation
409
Cables according to international Approvals / Data Cables UL/CSA
410
Cables according to international Approvals / Data Cables UL/CSA
SENSORFLEX / VERTEILERFLEX
two-approvals sensor actuator and distributor cables PVC, PUR, PVC/PUR
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
For decentralised installation and control technology. These cables are used in connector systems for sensors and actuators. In combination with
injected circular connectors and installed actuator-sensor boxes, they constitute an important connecting element between the periphery and the PLC
in production systems. The assembled cables offer attractive opportunities for reducing costs, not only in the field of automation technology, but also
in the entire manufacturing industry. While previously it was necessary to carry out time-consuming wiring of switchgear cabinets and machines, now
N
field bus technology has made it possible to move the periphery interfaces from the switchgear cabinets to the machines and systems. Moving the
I/O points to the system periphery enables significant reductions in installation costs.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
SENSORFLEX 2-APPROVALS
Part no. Cable structure AWG-No.
Sheath colour No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** app. mm weight app.
mm kg / km kg / km
78284 GY RAL 7001 3 x 0,25 PUR BN, BU, BK X 4,4 7,2 18,0 24
79907 GY RAL 7001 4 x 0,25 PUR BN, BU, BK, WH X 4,7 9,6 18,0 24
78286 GY RAL 7001 6 x 0,25 PVC BN, BU, BK, WH, GY, PK X 5,2 14,4 36,0 24
76345 GY RAL 7001 3 x 0,34 PVC BN, BU, BK X 4,9 9,8 30,0 22
76347 GY RAL 7001 4 x 0,34 PVC BN, BU, BK, WH X 5,2 13,1 43,0 22
76348 GY RAL 7001 5 G 0,34 PVC/PUR BN, BU, BK, WH, GN-YE X 5,9 16,4 54,0 22
76349 GY RAL 7001 5 G 0,34 PVC/PUR BN, BU, BK, WH, GN-YE X 5,9 16,4 54,0 22
78287 GY RAL 7001 5 G 0,34 PVC/PUR BK with number, GN-YE X 5,9 16,4 54,0 22
79850 GY RAL 7001 5 G 0,34 PUR BN, BU, BK, WH, GN-YE X 5,9 16,4 54,0 22
73571 GY RAL 7001 3 G 0,75 PVC BK with number, GN-YE X 6,7 21,6 58,0 18
75642 BK RAL 9005 3 G 0,75 PUR BK with number, GN-YE X 5,9 21,6 58,0 18
76351 GY RAL 7001 3 G 0,75 PVC BN, BU, GN-YE X 6,7 28,8 88,0 18
78288 GY RAL 7001 3 G 0,75 PUR BK with number, GN-YE X 5,9 21,6 58,0 18
Continuation
411
Cables according to international Approvals / Data Cables UL/CSA
SENSORFLEX / VERTEILERFLEX
two-approvals sensor actuator and distributor cables PVC, PUR, PVC/PUR
SENSORFLEX 2-APPROVALS
Part no. Cable structure AWG-No.
Sheath colour No.cores x Sheath Core colours Fine High Outer Cop. Weight
cross-sec. material wire flex ** app. mm weight app.
mm kg / km kg / km
74551 GY RAL 7001 4 G 0,75 PUR BK with number, GN-YE X 6,9 29,0 66,0 18
78289 GY RAL 7001 4 G 0,75 PVC/PUR BK with number, GN-YE X 7,0 29,0 66,0 18
77352 BK RAL 9005 2x1 PVC SW mit Ziffer 1-2 X 7,2 19,2 56,0 17
78290 GY RAL 7001 2x1 PVC SW mit Ziffer 1-2 X 7,2 19,2 56,0 17
76350 GY RAL 7001 11 G 1 PVC/PUR BK with number 1-8, BN, BU, GN-YE X 12,0 105,6 225,0 17
78291 GY RAL 7001 2 x 1,5 PVC BN, BU X 6,8 29,0 75,0 16
73587 GY RAL 7001 3 G 1,5 PVC BN, BU, GN-YE X 6,9 44,0 94,0 16
412
Cables according to international Approvals / Data Cables UL/CSA
Application
As a flexible interconnecting cable for electronics, control and command technology, as well as in measurement, signal, and pulse technology. Fast N
and inexpensive contacting by cutting and clamping technology.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Part no. No.cores x AWG-No. Outer Cop. Weight Part no. Part no. No.cores x AWG-No. Outer Cop. Weight
Sheath Sheath cross-sec. app. weight app. Sheath Sheath cross-sec. app. weight app.
colour colour mm mm kg / km kg / km colour colour mm mm kg / km kg / km
grey black grey black
83254 83976 2 x 0,14 26 3,9 12,6 20,0 83270 83987 2 x 0,23 24 4,3 16,1 20,0
83255 83977 3 x 0,14 26 4,2 13,7 25,0 83271 83988 3 x 0,23 24 4,5 18,9 25,0
83256 83978 4 x 0,14 26 4,4 14,9 28,0 83272 83989 4 x 0,23 24 4,8 23,0 30,0
83257 83979 6 x 0,14 26 5,0 18,9 30,0 83273 83990 6 x 0,23 24 5,4 32,8 40,0
83258 83980 10 x 0,14 26 6,1 29,5 50,0 83274 83991 10 x 0,23 24 6,5 50,9 60,0
83259 83981 12 x 0,14 26 6,3 31,4 53,0 83275 83992 12 x 0,23 24 6,7 59,1 70,0
83260 83982 16 x 0,14 26 6,8 43,9 60,0 83276 83993 16 x 0,23 24 7,4 68,4 90,0
83261 83983 18 x 0,14 26 7,1 52,1 70,0 83277 83994 18 x 0,23 24 7,7 79,5 123,0
83262 83984 24 x 0,14 26 8,0 62,8 100,0 83278 83995 24 x 0,23 24 8,8 97,3 131,0
83263 83985 27 x 0,14 26 8,4 66,3 105,0 83279 83996 27 x 0,23 24 9,0 122,0 160,0
83264 83986 30 x 0,14 26 8,6 70,4 110,0 83280 83997 30 x 0,23 24 9,3 132,0 170,0
Continuation
413
Cables according to international Approvals / Data Cables UL/CSA
414
Cables according to international Approvals / Data Cables UL/CSA
Application
As a flexible interconnecting cable for electronics, control and command technology, as well as in measurement, signal, and pulse technology. Fast
and inexpensive contacting by cutting and clamping technology.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Part no. No.cores x AWG-No. Outer Cop. Weight Part no. Part no. No.cores x AWG-No. Outer Cop. Weight
N
Sheath Sheath cross-sec. app. weight app. Sheath Sheath cross-sec. app. weight app.
colour colour mm mm kg / km kg / km colour colour mm mm kg / km kg / km
grey black grey black
83350 65114 2 x 2,08 14 9,1 92,1 180,0 83362 65125 2 x 3,2 12 10,0 131,4 200,0
83351 65115 3 x 2,08 14 9,6 140,6 220,0 83363 65126 3 x 3,2 12 10,6 162,6 240,0
83352 65116 4 x 2,08 14 10,4 162,4 270,0 83364 65127 4 x 3,2 12 11,4 221,7 300,0
83353 65117 6 x 2,08 14 12,1 200,0 380,0 83365 65128 6 x 3,2 12 14,4 328,1 400,0
83354 65118 10 x 2,08 14 16,0 313,1 600,0 83366 65129 10 x 3,2 12 17,8 401,8 580,0
83355 65119 12 x 2,08 14 16,5 417,6 770,0 83367 65130 12 x 3,2 12 18,4 460,2 800,0
83356 65120 16 x 2,08 14 18,1 510,3 870,0 83368 65131 16 x 3,2 12 20,6 532,3 900,0
83357 65121 18 x 2,08 14 19,4 540,4 990,0 83369 65132 18 x 3,2 12 22,7 573,4 1000,0
83358 65122 24 x 2,08 14 23,4 0,0 1300,0 83370 65133 24 x 3,2 12 26,1 626,8 1300,0
83359 65123 27 x 2,08 14 23,9 604,2 1400,0
83360 65124 30 x 2,08 14 24,6 660,1 1610,0
415
Cables according to international Approvals / Data Cables UL/CSA
Application
HELUKABEL TRAYCONTROL 300 is a screened, multi-core PVC data and control cable. Cross-sections with PLTC-ER and ITC-ER approval suitable
for open, unprotected installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as connecting
and joining cables and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates installation inside and
outside of machines and switch cabinets. The double-screening with aluminium foil (100% coverage) and copper braid (approx. 85% coverage)
guarantee superior EMC protection. Applications: tool machines, control panels, measuring devices, production automation, cable ducts, renewable
energies.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Cross- No.cores Outer Cop. Weight Part no. Cross- No.cores Outer Cop. Weight
section mm x AWG-No. app. mm weight app. section mm x AWG-No. app. mm weight app.
kg / km kg / km kg / km kg / km
62710 0,093 2 x 28 4,5 6,0 16,0 62738 0,241 8 x 24 6,4 31,0 57,0
62711 0,093 3 x 28 4,7 7,0 22,0 62739 0,241 10 x 24 7,3 39,0 67,0
62712 0,093 4 x 28 5,0 9,0 27,0 62740 0,241 15 x 24 8,2 51,0 85,0
62713 0,093 6 x 28 5,5 12,0 34,0 62741 0,241 20 x 24 9,0 64,0 106,0
62714 0,093 8 x 28 5,8 15,0 37,0 62742 0,241 25 x 24 9,9 77,0 128,0
62715 0,093 10 x 28 6,4 18,0 43,0 62743 0,241 30 x 24 10,3 92,0 155,0
62716 0,093 15 x 28 7,0 24,0 52,0 62744 0,241 40 x 24 11,4 118,0 206,0
62717 0,093 20 x 28 7,6 30,0 67,0 62745 0,241 50 x 24 13,2 148,0 249,0
62718 0,093 25 x 28 8,6 37,0 79,0 62746 0,382 2 x 22 6,6 19,0 34,0
62719 0,093 30 x 28 8,9 43,0 88,0 62747 0,382 3 x 22 5,5 22,0 40,0
62720 0,093 40 x 28 9,7 54,0 112,0 62748 0,382 4 x 22 5,8 27,0 46,0
62721 0,093 50 x 28 11,4 67,0 131,0 62749 0,382 6 x 22 6,5 34,0 60,0
62722 0,154 2 x 26 4,7 9,0 24,0 62750 0,382 8 x 22 9,3 45,0 72,0
62723 0,154 3 x 26 4,9 10,0 27,0 62751 0,382 10 x 22 9,8 69,0 85,0
62724 0,154 4 x 26 5,1 12,0 31,0 62752 0,382 15 x 22 9,7 77,0 115,0
62725 0,154 6 x 26 5,8 16,0 39,0 62753 0,382 20 x 22 11,1 92,0 140,0
62726 0,154 8 x 26 6,1 19,0 43,0 62754 0,382 25 x 22 12,6 121,0 176,0
62727 0,154 10 x 26 6,8 24,0 51,0 62755 0,382 30 x 22 13,0 139,0 210,0
62728 0,154 15 x 26 7,5 31,0 66,0 62756 0,382 40 x 22 14,1 177,0 273,0
62729 0,154 20 x 26 8,3 40,0 79,0 62757 0,382 50 x 22 15,5 215,0 331,0
62730 0,154 25 x 26 9,2 49,0 92,0 62758 0,616 2 x 20 7,4 28,0 73,0
62731 0,154 30 x 26 9,5 57,0 110,0 62759 0,616 3 x 20 7,7 34,0 77,0
62732 0,154 40 x 26 10,4 72,0 136,0 62760 0,616 4 x 20 8,3 40,0 91,0
62733 0,154 50 x 26 12,1 88,0 165,0 62761 0,616 6 x 20 8,6 54,0 118,0
62734 0,241 2 x 24 4,9 15,0 30,0 62762 0,616 8 x 20 9,1 70,0 158,0
62735 0,241 3 x 24 5,1 16,0 33,0 62763 0,616 10 x 20 10,4 83,0 173,0
62736 0,241 4 x 24 5,3 19,0 37,0 62764 0,616 15 x 20 12,9 119,0 218,0
62737 0,241 6 x 24 6,1 27,0 48,0 62765 0,616 20 x 20 14,8 130,0 298,0
Continuation
416
Cables according to international Approvals / Data Cables UL/CSA
417
Cables according to international Approvals / Data Cables UL/CSA
Application
Flexiblescreenedpaircableconnection,as control,signaland measuring cablesin tool machinery,conveyor belts and,inplant construction,air conditioning,in
foundries and steel mills.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x AWG-No. Outer Cop. Weight Part no. No.pairs x AWG-No. Outer Cop. Weight
Sheath Sheath cross-sec. app. mm weight app. Sheath Sheath cross-sec. app. mm weight app.
colour colour mm kg / km kg / km colour colour mm kg / km kg / km
grey black grey black
83774 65314 1 x 2 x 0,14 26 4,0 15,7 32,0 83792 65332 1 x 2 x 0,23 24 4,2 16,4 46,0
83775 65315 2 x 2 x 0,14 26 5,6 19,5 39,0 83793 65333 2 x 2 x 0,23 24 5,9 27,4 53,0
83776 65316 3 x 2 x 0,14 26 5,8 23,7 47,0 83794 65334 3 x 2 x 0,23 24 6,2 31,7 65,0
83777 65317 4 x 2 x 0,14 26 6,3 26,9 55,0 83795 65335 4 x 2 x 0,23 24 6,7 37,4 79,0
83778 65318 5 x 2 x 0,14 26 6,7 31,2 68,0 83796 65336 5 x 2 x 0,23 24 7,2 54,7 98,0
83779 65319 6 x 2 x 0,14 26 7,3 49,7 86,0 83797 65337 6 x 2 x 0,23 24 7,7 65,6 114,0
83780 65320 7 x 2 x 0,14 26 7,3 52,0 92,0 83798 65338 7 x 2 x 0,23 24 7,7 60,2 121,0
83781 65321 8 x 2 x 0,14 26 7,8 53,9 97,0 83799 65339 8 x 2 x 0,23 24 8,4 74,1 129,0
83782 65322 10 x 2 x 0,14 26 9,1 59,6 111,0 83800 65340 10 x 2 x 0,23 24 9,9 109,3 152,0
83783 65323 12 x 2 x 0,14 26 9,8 67,1 141,0 83801 65341 12 x 2 x 0,23 24 10,2 115,8 189,0
83784 65324 14 x 2 x 0,14 26 10,5 75,2 150,0 83802 65342 14 x 2 x 0,23 24 10,9 120,7 213,0
83785 65325 15 x 2 x 0,14 26 11,1 77,3 154,0 83803 65343 15 x 2 x 0,23 24 11,4 132,4 225,0
83786 65326 16 x 2 x 0,14 26 11,1 80,4 155,0 83804 65344 16 x 2 x 0,23 24 11,4 141,6 227,0
83787 65327 18 x 2 x 0,14 26 11,8 84,2 170,0 83805 65345 18 x 2 x 0,23 24 12,2 146,6 238,0
83788 65328 20 x 2 x 0,14 26 12,4 98,2 183,0 83806 65346 20 x 2 x 0,23 24 12,7 160,6 270,0
83789 65329 22 x 2 x 0,14 26 13,1 104,1 207,0 83807 65347 22 x 2 x 0,23 24 13,5 170,8 300,0
83790 65330 24 x 2 x 0,14 26 13,6 112,0 228,0 83808 65348 24 x 2 x 0,23 24 14,5 229,7 321,0
83791 65331 25 x 2 x 0,14 26 15,1 114,4 239,0 83809 65349 25 x 2 x 0,23 24 14,8 231,4 340,0
Continuation
418
Cables according to international Approvals / Data Cables UL/CSA
419
Cables according to international Approvals / Data Cables UL/CSA
Application
HELUKABEL TRAYCONTROL 300 is a screened, twisted pair data and control cable. Cross-sections with PLTC-ER and ITC-ER approval suitable for
open, unprotected installation in cable trays to the machine; their outstanding oil resistance (OIL RES I & II) makes them ideally suited as connecting
and joining cables and also for control, signal and measuring systems in industrial plants. The flexible cable structure facilitates installation inside and
outside of machines and switch cabinets. The double-screening with aluminium foil (100% coverage) and copper braid (approx. 85% coverage)
guarantee superior EMC protection. Applications: tool machines, control panels, measuring devices, production automation, cable ducts, renewable
energies.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. Cross- No.pairs x Outer Cop. Weight Part no. Cross- No.pairs x Outer Cop. Weight
section mm No.cores app. mm weight app. section mm No.cores app. mm weight app.
x kg / km kg / km x kg / km kg / km
AWG-no. AWG-no.
61999 0,154 1 x 2 x 26 4,7 16,0 32,0 59785 0,241 10 x 2 x 24 10,5 109,0 152,0
59760 0,154 2 x 2 x 26 5,7 20,0 39,0 59786 0,241 12 x 2 x 24 10,8 116,0 189,0
59761 0,154 3 x 2 x 26 5,9 24,0 47,0 59787 0,241 14 x 2 x 24 12,6 121,0 213,0
59762 0,154 4 x 2 x 26 6,4 27,0 55,0 59788 0,241 15 x 2 x 24 12,4 132,0 225,0
59763 0,154 5 x 2 x 26 6,8 31,0 68,0 59789 0,241 16 x 2 x 24 12,9 142,0 227,0
59764 0,154 6 x 2 x 26 7,4 50,0 86,0 59790 0,241 18 x 2 x 24 13,8 147,0 238,0
59765 0,154 7 x 2 x 26 7,5 52,0 92,0 59791 0,241 20 x 2 x 24 14,4 161,0 270,0
59766 0,154 8 x 2 x 26 7,9 54,0 97,0 59792 0,241 22 x 2 x 24 15,3 171,0 300,0
59767 0,154 10 x 2 x 26 9,2 60,0 111,0 59793 0,241 24 x 2 x 24 16,4 230,0 321,0
59768 0,154 12 x 2 x 26 9,8 67,0 141,0 59794 0,241 25 x 2 x 24 16,7 231,0 340,0
59769 0,154 14 x 2 x 26 10,4 75,0 150,0 59795 0,382 1 x 2 x 22 6,9 17,0 58,0
59770 0,154 15 x 2 x 26 10,8 77,0 154,0 59796 0,382 2 x 2 x 22 9,3 37,0 65,0
59771 0,154 16 x 2 x 26 11,2 80,0 155,0 59797 0,382 3 x 2 x 22 9,7 45,0 79,0
59772 0,154 18 x 2 x 26 11,8 84,0 170,0 59798 0,382 4 x 2 x 22 10,5 54,0 88,0
59773 0,154 20 x 2 x 26 12,4 98,0 183,0 59799 0,382 5 x 2 x 22 11,4 63,0 110,0
59774 0,154 22 x 2 x 26 13,1 104,0 207,0 59800 0,382 6 x 2 x 22 12,1 73,0 126,0
59775 0,154 24 x 2 x 26 13,6 112,0 228,0 59801 0,382 7 x 2 x 22 12,3 79,0 140,0
59776 0,154 25 x 2 x 26 15,1 114,0 239,0 59802 0,382 8 x 2 x 22 13,2 88,0 148,0
59777 0,241 1 x 2 x 24 4,9 16,0 46,0 59803 0,382 10 x 2 x 22 15,7 107,0 184,0
59778 0,241 2 x 2 x 24 6,6 27,0 53,0 59804 0,382 12 x 2 x 22 16,0 122,0 210,0
59779 0,241 3 x 2 x 24 6,9 32,0 65,0 59805 0,382 14 x 2 x 22 16,3 138,0 241,0
59780 0,241 4 x 2 x 26 7,8 37,0 79,0 59806 0,382 15 x 2 x 22 16,6 154,0 245,0
59781 0,241 5 x 2 x 24 8,0 55,0 98,0 59807 0,382 16 x 2 x 22 16,8 161,0 251,0
59782 0,241 6 x 2 x 24 8,4 66,0 114,0 59808 0,382 18 x 2 x 22 17,8 198,0 275,0
59783 0,241 7 x 2 x 24 8,8 60,0 121,0 59809 0,382 20 x 2 x 22 18,4 211,0 300,0
59784 0,241 8 x 2 x 24 9,5 74,0 129,0 59810 0,382 22 x 2 x 22 19,3 218,0 320,0
Continuation
420
Cables according to international Approvals / Data Cables UL/CSA
421
UL/CSA DRAG CHAIN CABLES
422
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA
JZ-602 RC cable for drag chains, 90C, 600 V, two approval control
cable, meter marking
Application
For use in dry, damp and wet rooms with free movement without tensile stress or forced movements as highly flexible PVC control cable suitable for
frequent lifting and bending stress in the machinery and tooling, robot technology and permanently moving machine parts. Convincingly proved in
the standard use of drag chains. Interesting for the export-oriented machinery plant. For applications that go beyond standard solutions (e. g.
composting facilities or high shelf conveyors with extremely high speed, etc.) we recommend you to our specially developed inquiry sheet for energy
guiding systems, further technical details see selection table: Conductors for cable drag chains in the opening credits. For use in cable drag chains
please note installation instruction.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC. N
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
89900 3 G 0,5 20 6,0 14,0 58,0 89926 25 G 1,5 16 19,8 360,0 625,0
89901 4 G 0,5 20 6,5 19,0 69,0 89927 34 G 1,5 16 22,4 490,0 840,0
89902 5 G 0,5 20 7,1 24,0 84,0 89932 3 G 2,5 14 8,9 72,0 150,0
89903 7 G 0,5 20 8,2 34,0 123,0 89928 4 G 2,5 14 10,1 96,0 185,0
89904 9 G 0,5 20 10,0 43,2 177,0 89933 5 G 2,5 14 11,3 120,0 242,0
89905 12 G 0,5 20 10,5 58,2 192,0 89929 7 G 2,5 14 13,6 168,0 293,0
89906 18 G 0,5 20 12,5 86,0 256,0 89934 12 G 2,5 14 16,8 288,0 498,0
89907 25 G 0,5 20 15,2 120,0 358,0 89935 3G4 12 10,9 115,0 231,0
89908 34 G 0,5 20 17,1 163,0 487,0 89930 4G4 12 12,4 154,0 298,0
89909 3G1 18 6,6 23,8 88,0 89936 5G4 12 13,8 192,0 370,0
89910 4G1 18 7,1 31,7 101,0 89931 7G4 12 16,6 269,0 460,0
89911 5G1 18 7,8 39,6 126,0 89937 4G6 10 14,6 231,0 430,0
89912 7G1 18 9,2 55,4 145,0 89938 4 G 10 8 18,2 384,0 720,0
89913 9G1 18 11,0 71,2 168,0 89939 4 G 16 6 22,6 615,0 1060,0
89914 12 G 1 18 11,5 95,0 260,0 89940 4 G 25 4 26,5 960,0 1590,0
89915 15 G 1 18 13,2 119,0 300,0 89941 4 G 35 2 30,8 1344,0 2105,0
89916 18 G 1 18 14,0 142,4 360,0
89917 25 G 1 18 17,2 197,8 640,0
89918 34 G 1 18 19,1 269,0 730,0
89919 3 G 1,5 16 7,4 44,0 94,0
89920 4 G 1,5 16 8,0 58,0 117,0
89921 5 G 1,5 16 8,8 72,0 140,0
89922 7 G 1,5 16 10,8 101,0 186,0
89923 9 G 1,5 16 12,8 129,7 244,0
89924 12 G 1,5 16 13,5 173,0 319,0
89925 18 G 1,5 16 16,0 260,0 451,0
423
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA
Note
Advantages
Highly-flexible, simple installation
Available on request
with blue cores (DC)
with red cores (AC)
Grey or TPE outer sheath
Application
HELUKABEL MULTIFLEX 600 is a highly-flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this cable
to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 edition 2012. Approved for open, unprotected
installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life; for industrial applications in dry,
damp and wet environments. Recommended applications: production lines, bottling plants, machine construction, switch cabinets, conveyor systems,
packaging machines, automotive industry. Please observe applicable installation regulations for use in energy supply chains.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
62502 2 x 0,5 20 6,9 10,0 53,0 62529 25 G 1,5 16 20,8 360,0 665,0
62503 3 G 0,5 20 7,3 14,0 61,0 62530 34 G 1,5 16 23,0 490,0 1084,0
62504 4 G 0,5 20 8,0 19,0 72,0 62531 41 G 1,5 16 25,1 590,0 1260,0
62505 5 G 0,5 20 8,6 24,0 85,0 62532 50 G 1,5 16 27,7 720,0 1521,0
62506 7 G 0,5 20 9,9 34,0 110,0 62533 60 G 1,5 16 29,5 864,0 1885,0
62507 12 G 0,5 20 11,4 58,0 158,0 62534 3 G 2,5 14 9,8 72,0 160,0
62508 18 G 0,5 20 14,2 86,0 241,0 63136 4 G 2,5 14 10,6 96,0 173,0
62509 25 G 0,5 20 17,0 120,0 316,0 62535 5 G 2,5 14 11,9 120,0 268,0
62510 34 G 0,5 20 18,9 163,0 439,0 62536 7 G 2,5 14 13,6 168,0 307,0
62511 3 G 0,75 18 7,8 22,0 75,0 62537 9 G 2,5 14 16,1 216,0 437,0
62512 4 G 0,75 18 8,6 29,0 91,0 62538 12 G 2,5 14 16,9 288,0 572,0
62513 5 G 0,75 18 9,3 36,0 103,0 62539 18 G 2,5 14 20,1 432,0 800,0
62514 7 G 0,75 18 10,8 50,0 136,0 62540 25 G 2,5 14 25,1 600,0 1100,0
62515 12 G 0,75 18 12,4 86,0 228,0 62541 3G4 12 11,3 115,0 221,0
62516 15 G 0,75 18 13,8 108,0 273,0 62542 4G4 12 12,4 154,0 247,0
62517 18 G 0,75 18 15,4 130,0 311,0 62543 5G4 12 13,8 192,0 318,0
62518 25 G 0,75 18 18,5 180,0 498,0 62544 7G4 12 16,9 269,0 438,0
62519 34 G 0,75 18 20,5 245,0 550,0 62545 4G6 10 15,3 230,0 383,0
62520 36 G 0,75 18 20,6 259,0 570,0 62546 5G6 10 16,6 288,0 481,0
62521 42 G 0,75 18 22,3 302,0 600,0 62547 7G6 10 18,2 403,0 800,0
62522 3 G 1,5 16 8,6 43,0 100,0 62548 4 G 10 8 19,7 384,0 671,0
62523 4 G 1,5 16 9,5 58,0 122,0 62549 5 G 10 8 22,0 480,0 990,0
62524 5 G 1,5 16 10,3 72,0 148,0 62550 4 G 16 6 23,7 614,0 951,0
62525 7 G 1,5 16 12,0 101,0 197,0 62551 5 G 16 6 26,1 768,0 1500,0
62526 9 G 1,5 16 14,2 130,0 244,0 62552 4 G 25 4 34,0 960,0 1700,0
62527 12 G 1,5 16 14,7 173,0 328,0 62554 4 G 35 2 37,0 1344,0 2300,0
62528 18 G 1,5 16 17,2 259,0 459,0
424
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED 500-C-PVC UL/CSA,
N
confer page 429
Application
UL/CSA approved HELUKABEL MULTISPEED 500-PVC are installed there, where extreme requirements for the cables are necessary. Designed for
the export-orientated machinery manufacturer, specifically for USA and Canada. Matched materials and stranding technique permit continuous use
as a highly flexible cable for drag chains with long travel and high or slow speeds. For use in dry, damp rooms, and outdoors, with free movement
without tensile stress or forced movements as a highly flexible PVC control cable suitable for frequent lifting and bending stress in engineering and
tool manufacturing.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24295 2 x 0,5 20 4,8 9,6 40,0 24315 12 G 1 18 12,3 115,0 227,0
24296 3 G 0,5 20 5,1 14,4 45,0 24316 18 G 1 18 15,1 173,0 351,0
24297 4 G 0,5 20 5,5 19,0 57,0 24317 25 G 1 18 17,6 240,0 489,0
24298 5 G 0,5 20 6,0 24,0 66,0 24318 3 G 1,5 16 6,7 43,0 88,0
24299 7 G 0,5 20 9,1 33,6 81,0 24319 4 G 1,5 16 7,3 58,0 110,0
24300 12 G 0,5 20 10,0 58,0 133,0 24320 5 G 1,5 16 8,0 72,0 130,0
24301 18 G 0,5 20 12,2 86,0 194,0 24321 7 G 1,5 16 13,2 101,0 182,0
24302 25 G 0,5 20 14,3 120,0 274,0 24322 12 G 1,5 16 14,4 173,0 319,0
24303 4 G 0,75 19 6,1 29,0 63,0 24323 18 G 1,5 16 17,7 259,0 420,0
24304 5 G 0,75 19 6,6 36,0 79,0 24324 25 G 1,5 16 20,5 360,0 604,0
24305 7 G 0,75 19 10,5 50,0 107,0 24325 4 G 2,5 14 8,9 96,0 172,0
24306 12 G 0,75 19 11,4 86,0 169,0 24326 5 G 2,5 14 9,9 120,0 219,0
24307 18 G 0,75 19 14,2 130,0 247,0 24327 7 G 2,5 14 16,1 168,0 303,0
24308 25 G 0,75 19 16,3 180,0 366,0 24328 12 G 2,5 14 17,8 288,0 504,0
24309 36 G 0,75 19 20,1 259,0 540,0 24329 18 G 2,5 14 21,8 432,0 754,0
24310 42 G 0,75 19 22,2 302,0 630,0 24330 25 G 2,5 14 24,4 600,0 940,0
24311 3G1 18 5,9 29,0 69,0
24312 4G1 18 6,4 38,4 86,0
24313 5G1 18 7,0 48,0 101,0
24314 7G1 18 11,2 67,0 140,0
425
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA
JZ-HF-FCY high flexible, cable for drag chains, oil resistant, EMC-preferred
type, meter marking
Application
UL/CSA approved, highly flexible, screened PVC drag-chain cable for laying in dry, damp and wet rooms, with free movement and without tensile
load or forced movements, suitable for frequent lifting and bending stresses in the sector of machine manufacture and tool making. Thanks to the
high level of shielding density, a fault-free transmission of signals or impulses is ensured. The ideal control line, offering protection against interference,
for the above applications. Of interest for those machinery manufacturers, who are export orientated. For applications which go beyond standard
solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially
developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection
table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12908 2 x 0,5 20 6,0 35,0 46,0 12926 4G1 18 7,8 71,0 114,0
12909 3 G 0,5 20 6,3 42,0 56,0 12927 5G1 18 8,4 88,0 136,0
12910 4 G 0,5 20 6,8 47,0 64,0 12928 7G1 18 9,8 111,0 169,0
12911 5 G 0,5 20 7,4 56,0 77,0 12929 12 G 1 18 12,0 184,0 270,0
12912 7 G 0,5 20 8,5 69,0 104,0 12930 18 G 1 18 14,2 260,0 385,0
12913 12 G 0,5 20 10,1 108,0 158,0 12931 25 G 1 18 16,8 349,0 530,0
12914 18 G 0,5 20 11,7 145,0 229,0 12932 2 x 1,5 16 7,3 63,0 88,0
12915 25 G 0,5 20 14,0 240,0 320,0 12933 3 G 1,5 16 7,7 80,0 104,0
12916 2 x 0,75 19 6,4 40,0 59,0 12934 4 G 1,5 16 8,4 97,0 136,0
12917 3 G 0,75 19 6,8 52,0 68,0 12935 5 G 1,5 16 9,1 119,0 170,0
12918 4 G 0,75 19 7,3 60,0 82,0 12936 7 G 1,5 16 10,7 147,0 221,0
12919 5 G 0,75 19 7,9 71,0 101,0 12937 12 G 1,5 16 13,0 267,0 348,0
12920 7 G 0,75 19 9,2 91,0 150,0 12938 18 G 1,5 16 15,5 374,0 489,0
12921 12 G 0,75 19 11,0 142,0 212,0 12939 25 G 1,5 16 18,7 526,0 710,0
12922 18 G 0,75 19 13,0 212,0 305,0 12940 3 G 2,5 14 9,1 144,0 177,0
12923 25 G 0,75 19 15,8 281,0 430,0 12941 4 G 2,5 14 9,9 148,0 204,0
12924 2x1 18 6,8 50,0 71,0 12942 7 G 2,5 14 13,0 255,0 340,0
12925 3G1 18 7,2 60,0 90,0 12943 4G4 12 11,2 230,0 310,0
426
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA
JZ-602 RC-CY special cable for drag chains, 90C, 600 V, two
approval control cable, EMC-preferred type, meter marking
Application
These cable are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist
and wet rooms. These special cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics, for
movable automated machinery parts. These cables have shown excellent performance in combination with standard cable trays. The dense screening
assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free control cable for the above applications. Interesting for N
the export-oriented machines and machinery plants. For applications which go beyond standard solutions we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for
drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
89950 3 G 0,5 20 8,5 45,0 124,0 89976 25 G 1,5 16 25,2 544,0 950,0
89951 4 G 0,5 20 9,0 52,0 135,0 89977 34 G 1,5 16 28,1 674,0 1203,0
89952 5 G 0,5 20 9,7 68,0 153,0 89984 3 G 2,5 14 11,8 141,0 220,0
89953 7 G 0,5 20 11,0 93,0 191,0 89978 4 G 2,5 14 13,2 170,0 270,0
89954 9 G 0,5 20 12,4 134,0 243,0 89985 5 G 2,5 14 14,2 195,0 350,0
89955 12 G 0,5 20 13,5 163,0 322,0 89979 7 G 2,5 14 17,4 251,0 428,0
89956 15 G 0,5 20 14,8 174,0 350,0 89986 12 G 2,5 14 21,0 368,0 730,0
89957 18 G 0,5 20 16,0 191,0 374,0 89980 18 G 2,5 14 25,4 639,0 1140,0
89958 25 G 0,5 20 19,0 223,0 436,0 89987 3G4 12 14,0 180,0 296,0
89959 3G1 18 8,9 56,0 130,0 89981 4G4 12 15,9 232,0 456,0
89960 4G1 18 9,7 81,0 155,0 89988 5G4 12 17,7 330,0 450,0
89961 5G1 18 10,4 90,0 181,0 89982 7G4 12 20,9 395,0 737,0
89962 7G1 18 12,0 106,0 208,0 89983 4G6 10 18,3 316,0 572,0
89963 9G1 18 14,1 161,0 321,0 89989 4 G 10 8 23,2 490,0 1012,0
89964 12 G 1 18 15,2 175,0 341,0 89990 4 G 16 6 27,6 850,0 1400,0
89965 15 G 1 18 16,7 204,0 396,0 89991 4 G 25 4 33,1 1450,0 2100,0
89966 18 G 1 18 17,6 241,0 473,0 89992 4 G 35 2 37,8 1890,0 2550,0
89967 25 G 1 18 20,7 342,0 650,0
89968 34 G 1 18 24,3 434,0 781,0
89969 3 G 1,5 16 10,2 89,0 165,0
89970 4 G 1,5 16 11,0 97,0 192,0
89971 5 G 1,5 16 11,8 111,0 224,0
89972 7 G 1,5 16 14,0 147,0 274,0
89973 9 G 1,5 16 16,4 193,0 340,0
89974 12 G 1,5 16 17,1 256,0 461,0
89975 18 G 1,5 16 20,2 360,0 674,0
427
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA
Note
Advantages
Highly-flexible, simple installation
Available on request
with blue cores (DC)
with red cores (AC)
Grey or TPE outer sheath
Application
HELUKABEL MULTIFLEX 600-C is a highly-flexible, oil-resistant control cable. The special combination of TC-ER, PLTC-ER and ITC-ER allows this
cable to be used as a connecting cable for industrial plant and machinery in accordance with NFPA 79 edition 2012. Approved for open, unprotected
installation in cable trays to the machine. Its outstanding oil resistance (OIL RES I & II) guarantees a long service life; for industrial applications in dry,
damp and wet environments. Recommended applications: Production lines, bottling plants, machine construction, switch cabinets, conveyor systems,
packaging machines, automotive industry. For the use in energy drag chains please note the installation guidelines.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
62556 2 x 0,5 20 7,7 30,0 80,0 62580 18 G 1,5 16 18,4 376,0 559,0
62557 3 G 0,5 20 8,0 37,0 85,0 62581 25 G 1,5 16 23,1 510,0 788,0
62558 4 G 0,5 20 8,7 46,0 100,0 62582 34 G 1,5 16 25,8 674,0 1203,0
62559 5 G 0,5 20 9,3 54,0 113,0 62583 3 G 2,5 14 10,3 141,0 218,0
62560 7 G 0,5 20 10,7 70,0 152,0 62584 4 G 2,5 14 11,5 149,0 222,0
62561 12 G 0,5 20 12,3 112,0 210,0 62585 5 G 2,5 14 12,4 195,0 350,0
62562 18 G 0,5 20 15,1 153,0 304,0 62586 7 G 2,5 14 15,4 243,0 373,0
62563 25 G 0,5 20 18,1 225,0 408,0 62587 9 G 2,5 14 16,8 312,0 479,0
62564 34 G 0,5 20 19,8 267,0 530,0 62588 12 G 2,5 14 18,5 368,0 730,0
62565 3 G 0,75 18 8,5 55,0 101,0 62589 18 G 2,5 14 22,4 639,0 1140,0
62566 4 G 0,75 18 9,3 69,0 127,0 62590 25 G 2,5 14 25,5 796,0 1530,0
62567 5 G 0,75 18 10,0 82,0 148,0 62591 3G4 12 11,7 180,0 296,0
62568 7 G 0,75 18 11,6 119,0 186,0 62592 4G4 12 13,3 221,0 305,0
62569 12 G 0,75 18 14,1 178,0 286,0 62593 5G4 12 14,7 330,0 450,0
62570 15 G 0,75 18 15,2 175,0 455,0 62594 7G4 12 17,8 363,0 536,0
62571 18 G 0,75 18 16,3 252,0 383,0 62595 4G6 10 16,1 314,0 469,0
62572 25 G 0,75 18 19,6 362,0 514,0 62596 5G6 10 17,5 441,0 772,0
62573 34 G 0,75 18 21,9 473,0 685,0 62597 7G6 10 20,6 505,0 1028,0
62574 3 G 1,5 16 9,3 75,0 131,0 62598 4 G 10 8 21,9 526,0 790,0
62575 4 G 1,5 16 10,2 93,0 165,0 62599 5 G 10 8 24,1 610,0 1096,0
62576 5 G 1,5 16 11,0 113,0 195,0 62600 4 G 16 6 24,8 730,0 1621,0
62577 7 G 1,5 16 12,9 162,0 250,0 62602 5 G 16 6 27,2 1050,0 1759,0
62578 9 G 1,5 16 15,2 193,0 340,0 62603 4 G 25 4 33,1 1450,0 2100,0
62579 12 G 1,5 16 15,6 249,0 393,0 62605 4 G 35 2 37,8 1840,0 2550,0
428
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA
Application
For permanently use on long distances, and high or low speeds. These high flexible PVC control cables are suitable for shift- and bending stresses in
machines and machine tool constructions. These are installed in dry, moist rooms and in open air with free movement without tensile stress or forced
movements. These screened cables are particularly suitable for the interference-free transmission in instrumentation and control engineering applications.
For applications which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems. Before
installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24335 2 x 0,5 20 6,6 30,0 88,0 24352 3G1 18 7,7 59,0 131,0
24336 3 G 0,5 20 6,9 36,0 101,0 24353 4G1 18 8,3 70,0 164,0
24337 4 G 0,5 20 7,3 42,0 116,0 24354 5G1 18 9,1 84,0 198,0
24338 5 G 0,5 20 7,8 48,0 146,0 24355 7G1 18 14,0 106,0 252,0
24339 7 G 0,5 20 11,3 64,0 181,0 24356 12 G 1 18 15,0 174,0 410,0
24340 9 G 0,5 20 11,4 80,0 219,0 24357 18 G 1 18 18,7 240,0 550,0
24341 12 G 0,5 20 12,6 105,0 271,0 24358 25 G 1 18 21,2 332,0 756,0
24342 18 G 0,5 20 15,0 137,0 374,0 24359 3 G 1,5 16 8,6 75,0 166,0
24343 25 G 0,5 20 17,1 210,0 542,0 24360 4 G 1,5 16 9,4 90,0 199,0
24344 2 x 0,75 19 6,8 40,0 96,0 24361 5 G 1,5 16 10,4 108,0 229,0
24345 3 G 0,75 19 7,4 48,0 111,0 24362 7 G 1,5 16 16,0 157,0 304,0
24346 4 G 0,75 19 8,0 55,0 140,0 24363 12 G 1,5 16 17,6 240,0 502,0
24347 5 G 0,75 19 8,5 66,0 161,0 24364 18 G 1,5 16 21,3 355,0 709,0
24348 7 G 0,75 19 12,9 85,0 227,0 24365 25 G 1,5 16 24,8 448,0 939,0
24349 12 G 0,75 19 14,4 135,0 317,0 24366 4 G 2,5 14 11,3 134,0 270,0
24350 18 G 0,75 19 17,5 190,0 486,0 24367 5 G 2,5 14 12,3 175,0 335,0
24351 25 G 0,75 19 19,9 275,0 651,0
429
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
JZ-602 RC-PUR special cable for drag chains, 80C, 600 V, two
approval control cable, meter marking
Application
These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist,
wet rooms and outdoor. These special cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics,
for movable automated machinery parts. For applications which go beyond standard solutions (for example for composting appliances or high shelf
conveyors with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before
installation in cable trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12630 3 G 0,5 20 6,0 14,0 58,0 12656 25 G 1,5 16 19,8 360,0 625,0
12631 4 G 0,5 20 6,5 19,0 69,0 12657 34 G 1,5 16 22,4 490,0 840,0
12632 5 G 0,5 20 7,1 24,0 84,0 12658 3 G 2,5 14 8,9 72,0 150,0
12633 7 G 0,5 20 8,2 34,0 123,0 12659 4 G 2,5 14 10,1 96,0 185,0
12634 9 G 0,5 20 10,0 43,2 177,0 12660 5 G 2,5 14 11,3 120,0 242,0
12635 12 G 0,5 20 10,5 58,2 192,0 12661 7 G 2,5 14 13,6 168,0 293,0
12636 18 G 0,5 20 12,5 86,0 256,0 12662 12 G 2,5 14 16,8 288,0 498,0
12637 25 G 0,5 20 15,2 120,0 358,0 12663 3G4 12 10,9 115,0 231,0
12638 34 G 0,5 20 17,1 163,0 487,0 12664 4G4 12 12,4 154,0 298,0
12639 3 G 0,75 18 6,6 23,8 88,0 12665 5G4 12 13,8 192,0 370,0
12640 4 G 0,75 18 7,1 31,7 101,0 12666 7G4 12 16,6 269,0 460,0
12641 5 G 0,75 18 7,8 39,6 126,0 12667 4G6 10 14,6 231,0 430,0
12642 7 G 0,75 18 9,2 55,4 145,0 12668 4 G 10 8 18,2 384,0 720,0
12643 9 G 0,75 18 11,0 86,4 168,0 12669 4 G 16 6 22,6 615,0 1060,0
12644 12 G 0,75 18 11,5 95,0 260,0 12670 4 G 25 4 26,5 960,0 1590,0
12645 15 G 0,75 18 13,2 119,0 300,0 12671 4 G 35 2 30,8 1344,0 2105,0
12646 18 G 0,75 18 14,0 142,4 360,0
12647 25 G 0,75 18 17,2 197,8 640,0
12648 34 G 0,75 18 19,1 269,0 730,0
12649 3 G 1,5 16 7,4 44,0 94,0
12650 4 G 1,5 16 8,0 58,0 117,0
12651 5 G 1,5 16 8,8 72,0 140,0
12652 7 G 1,5 16 10,8 101,0 186,0
12653 9 G 1,5 16 12,8 129,7 244,0
12654 12 G 1,5 16 13,5 173,0 319,0
12655 18 G 1,5 16 16,0 260,0 451,0
430
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Cleanroom qualification tested with analog
type. Please note "cleanroom qualified"
N
when ordering.
screened analogue type:
MULTIFLEX 512 -C-PUR UL/CSA,
confer page 437
Application
These special UL/CSA cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics, for movable
automated machinery parts and multi-shift operation. Those cables are developed according to the newest state of technology improvement. These
high flexible control cables with sliding abilities guaranteed an optimum service life durabilities and also very economic by using the PP-core insulation
and the PUR-outer sheath. The PUR material is adhesion-low and cut-resistant. For applications which go beyond standard solutions (for example for
composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for our especially developed enquiry sheet
for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for drag chain
cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
21559 2 x 0,5 20 5,5 9,6 38,0 21570 2 x 0,75 19 6,2 14,4 47,0
21560 3 G 0,5 20 5,8 14,4 46,0 21571 3 G 0,75 19 6,5 21,6 58,0
21561 4 G 0,5 20 6,4 19,0 59,0 21572 4 G 0,75 19 7,0 29,0 69,0
21562 5 G 0,5 20 7,0 24,0 68,0 21573 5 G 0,75 19 7,8 36,0 85,0
21563 7 G 0,5 20 8,1 33,6 88,0 21574 7 G 0,75 19 9,0 50,0 118,0
21564 12 G 0,5 20 9,9 58,0 131,0 21575 12 G 0,75 19 11,0 86,0 183,0
21565 18 G 0,5 20 11,5 86,0 197,0 21576 18 G 0,75 19 13,0 130,0 270,0
21566 20 G 0,5 20 12,0 96,0 260,0 21577 20 G 0,75 19 13,5 144,0 290,0
21567 25 G 0,5 20 13,7 120,0 282,0 21578 25 G 0,75 19 15,4 180,0 374,0
21568 30 G 0,5 20 14,3 144,0 315,0 21579 30 G 0,75 19 16,2 216,0 420,0
21569 36 G 0,5 20 15,3 172,0 374,0 21580 36 G 0,75 19 17,6 259,0 498,0
Continuation
431
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
432
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
N
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED 500-C-PUR UL/CSA,
confer page 439
Application
UL/CSA approved HELUKABEL MULTISPEED 500-PUR are installed there, where the extreme requirements for the cables are necessary. The selected
materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high an slow speed of
movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without tensile stress or forced movements.
These robust and abrasion resistant special control cables are installed there, where the problems appear for the application in permanent stresses e.
g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent movable machinery parts for multi-shift
operation. These cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing
speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the
instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24370 2 x 0,5 20 4,8 9,6 41,0 24378 3 G 0,75 19 5,2 21,6 51,0
24371 3 G 0,5 20 5,1 14,4 48,0 24379 4 G 0,75 19 6,1 29,0 68,0
24372 4 G 0,5 20 5,5 19,0 62,0 24380 5 G 0,75 19 6,6 36,0 73,0
24373 5 G 0,5 20 6,0 24,0 70,0 24381 7 G 0,75 19 10,5 50,0 92,0
24374 7 G 0,5 20 9,1 33,6 88,0 24382 12 G 0,75 19 11,4 86,0 170,0
24375 12 G 0,5 20 10,0 58,0 131,0 24383 18 G 0,75 19 14,2 130,0 257,0
24376 18 G 0,5 20 12,2 86,0 204,0 24384 25 G 0,75 19 16,3 180,0 280,0
24377 25 G 0,5 20 14,3 120,0 266,0 24385 36 G 0,75 19 20,1 260,0 411,0
24386 42 G 0,75 19 22,2 302,0 608,0
Continuation
433
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
434
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
Application
UL/CSA approved, highly flexible, screened PUR drag-chain cable for laying in dry, damp, wet rooms and outside, with free movement and without
tensile load or forced movements, suitable for frequent lifting and bending stresses in the sector of machine manufacture and tool making. Thanks to
the high level of shielding density, a fault-free transmission of signals or impulses is ensured. The ideal control line, offering protection against
interference, for the above applications. Of interest for those machinery manufacturers, who are export orientated. For applications which go beyond
standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for
N
our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12944 2 x 0,5 20 6,0 35,0 46,0 12962 4G1 18 7,8 71,0 114,0
12945 3 G 0,5 20 6,3 42,0 56,0 12963 5G1 18 8,4 88,0 136,0
12946 4 G 0,5 20 6,8 47,0 64,0 12964 7G1 18 9,8 111,0 169,0
12947 5 G 0,5 20 7,4 56,0 77,0 12965 12 G 1 18 12,0 184,0 270,0
12948 7 G 0,5 20 8,5 69,0 104,0 12966 18 G 1 18 14,2 260,0 385,0
12949 12 G 0,5 20 10,1 108,0 158,0 12967 25 G 1 18 16,8 349,0 530,0
12950 18 G 0,5 20 11,7 145,0 229,0 12968 2 x 1,5 16 7,3 63,0 88,0
12951 25 G 0,5 20 14,0 240,0 320,0 12969 3 G 1,5 16 7,7 80,0 104,0
12952 2 x 0,75 19 6,4 40,0 59,0 12970 4 G 1,5 16 8,4 97,0 136,0
12953 3 G 0,75 19 6,8 52,0 68,0 12971 5 G 1,5 16 9,1 119,0 170,0
12954 4 G 0,75 19 7,3 60,0 82,0 12972 7 G 1,5 16 10,7 147,0 221,0
12955 5 G 0,75 19 7,9 71,0 101,0 12973 12 G 1,5 16 13,0 267,0 348,0
12956 7 G 0,75 19 9,2 91,0 150,0 12974 18 G 1,5 16 15,5 374,0 489,0
12957 12 G 0,75 19 11,0 142,0 212,0 12975 25 G 1,5 16 18,7 526,0 710,0
12958 18 G 0,75 19 13,0 212,0 305,0 12976 3 G 2,5 14 9,1 144,0 177,0
12959 25 G 0,75 19 15,8 281,0 430,0 12977 4 G 2,5 14 9,9 148,0 204,0
12960 2x1 18 6,8 50,0 71,0 12978 7 G 2,5 14 13,0 255,0 340,0
12961 3G1 18 7,2 60,0 90,0 12979 4G4 12 11,2 230,0 310,0
435
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
JZ-602 RC-C-PUR special cable for drag chains, 80C, 600 V, two
approval control cable, EMC-preferred type, meter marking
Application
These cable are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist,
wet rooms and outdoor. These special cables for drag chains are used for permanent flexible applications in machineries, machine tools, robot technics,
for movable automated machinery parts. The dense screening assures disturbance-free transmission of all signals and impulses. An ideal disturbance-free
control cable for the above applications. For applications which go beyond standard solutions we recommend for our especially developed enquiry
sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for drag
chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
12680 3 G 0,5 20 8,5 45,0 124,0 12706 25 G 1,5 16 25,2 544,0 950,0
12681 4 G 0,5 20 9,0 52,0 135,0 12707 34 G 1,5 16 28,1 674,0 1203,0
12682 5 G 0,5 20 9,7 68,0 153,0 12708 3 G 2,5 14 11,8 141,0 220,0
12683 7 G 0,5 20 11,0 93,0 191,0 12709 4 G 2,5 14 13,2 170,0 270,0
12684 9 G 0,5 20 12,4 134,0 243,0 12710 5 G 2,5 14 14,2 195,0 350,0
12685 12 G 0,5 20 13,5 163,0 322,0 12711 7 G 2,5 14 17,4 251,0 428,0
12686 15 G 0,5 20 14,8 174,0 350,0 12712 12 G 2,5 14 21,0 368,0 730,0
12687 18 G 0,5 20 16,0 191,0 374,0 12713 18 G 2,5 14 25,4 639,0 1140,0
12688 25 G 0,5 20 19,0 223,0 436,0 12714 3G4 12 14,0 180,0 296,0
12689 3 G 0,75 18 8,9 56,0 130,0 12715 4G4 12 15,9 232,0 456,0
12690 4 G 0,75 18 9,7 81,0 155,0 12716 5G4 12 17,7 330,0 450,0
12691 5 G 0,75 18 10,4 90,0 181,0 12717 7G4 12 20,9 395,0 737,0
12692 7 G 0,75 18 12,0 106,0 208,0 12718 4G6 10 18,3 316,0 572,0
12693 9 G 0,75 18 14,1 161,0 321,0 12719 4 G 10 8 23,2 490,0 1012,0
12694 12 G 0,75 18 15,2 175,0 341,0 12720 4 G 16 6 27,6 850,0 1400,0
12695 15 G 0,75 18 16,7 204,0 396,0 12721 4 G 25 4 33,1 1450,0 2100,0
12696 18 G 0,75 18 17,6 241,0 473,0 12722 4 G 35 2 37,8 1890,0 2550,0
12697 25 G 0,75 18 20,7 342,0 650,0
12698 34 G 0,75 18 24,3 434,0 781,0
12699 3 G 1,5 16 10,2 89,0 165,0
12700 4 G 1,5 16 11,0 97,0 192,0
12701 5 G 1,5 16 11,8 111,0 224,0
12702 7 G 1,5 16 14,0 147,0 274,0
12703 9 G 1,5 16 16,4 193,0 340,0
12704 12 G 1,5 16 17,1 256,0 461,0
12705 18 G 1,5 16 20,2 360,0 674,0
436
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
Note
G = with green-yellow conductor
N
x = without green-yellow conductor (OZ)
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Please note the cleanroom qualification
when ordering.
unscreened analogue type:
MULTIFLEX 512 PUR UL/CSA,
confer page 431
Application
The special screened UL/CSA cables for drag chains are mainly applied for impulse transmission to prevent external interference effects and used for
permanent flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts and multi-shift operation.
Those cables are developed according to the newest state of technology improvement. These high flexible control cables with sliding abilities guaranteed
an optimum service life durabilities and also very economic by using the PP-core insulation and the PUR-outer sheath which is adhesive-free and
cut-resistant.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
21630 2 x 0,5 20 8,3 30,0 90,0 21636 18 G 0,5 20 14,7 157,0 325,0
21631 3 G 0,5 20 8,5 38,0 105,0 21637 20 G 0,5 20 15,4 167,0 350,0
21632 4 G 0,5 20 9,0 50,0 124,0 21638 25 G 0,5 20 17,1 240,0 450,0
21633 5 G 0,5 20 9,7 65,0 132,0 21639 30 G 0,5 20 17,9 273,0 510,0
21634 7 G 0,5 20 11,1 70,0 175,0 21640 36 G 0,5 20 19,2 306,0 580,0
21635 12 G 0,5 20 12,7 100,0 250,0
Continuation
437
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
438
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
Note
G = with green-yellow conductor
x = without green-yellow conductor (OZ) N
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
unscreened analogue type:
MULTISPEED 500-PUR UL/CSA,
confer page 433
Application
UL/CSA approved HELUKABEL MULTISPEED 500-C-PUR is used in applications where extreme requirements placed on the line. Designed for the
export-orientated machinery manufacturer, specifically for USA and Canada. The selected materials and lay-up technique permit these high flexible
cables for permanent application in drag chains for long distances, high an slow speed of movements. These cables are installed in dry, moist and wet
rooms and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are
installed there, where the problems appear for the application in permanent stresses e. g. in energy drag chains, industry robotics, production lines,
automatic control systems and permanent movable machinery parts for multi-shift operation. These cables are installed everywhere, where high
requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary. These screened cables are particularly suitable for the
interference-free transmission in instrumentation and control engineering applications. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24410 2 x 0,5 20 6,6 30,0 90,0 24419 2 x 0,75 19 6,8 40,0 100,0
24411 3 G 0,5 20 6,9 36,0 104,0 24420 3 G 0,75 19 7,4 48,0 117,0
24412 4 G 0,5 20 7,3 42,0 118,0 24421 4 G 0,75 19 8,0 55,0 143,0
24413 5 G 0,5 20 7,8 48,0 148,0 24422 5 G 0,75 19 8,5 66,0 167,0
24414 7 G 0,5 20 11,3 64,0 184,0 24423 7 G 0,75 19 12,9 85,0 229,0
24415 9 G 0,5 20 11,4 80,0 219,0 24424 12 G 0,75 19 14,4 135,0 319,0
24416 12 G 0,5 20 12,6 105,0 276,0 24425 18 G 0,75 19 17,5 190,0 492,0
24417 18 G 0,5 20 15,0 137,0 378,0 24426 25 G 0,75 19 19,9 275,0 659,0
24418 25 G 0,5 20 17,5 210,0 547,0
Continuation
439
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
440
Cables according to international Approvals / TPE-Cables for Drag Chains UL/CSA
Application
The selected materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high an slow
speed of movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without tensile stress or forced
movements. These robust and abrasion resistant special control cables are installed there, where the problems appear for the application in permanent
stresses e. g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent movable machinery parts for
multi-shift operation. These cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are
necessary. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please
read the instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24450 2 x 0,5 20 4,7 9,6 42,0 24458 2 x 0,75 19 5,0 14,4 47,0
24451 3 G 0,5 20 5,0 14,4 49,0 24459 3 G 0,75 19 5,2 21,6 55,0
24452 4 G 0,5 20 5,4 19,0 63,0 24460 4 G 0,75 19 6,1 29,0 70,0
24453 5 G 0,5 20 5,8 24,0 70,0 24461 5 G 0,75 19 6,6 36,0 74,0
24454 7 G 0,5 20 8,9 33,6 90,0 24462 7 G 0,75 19 10,5 50,0 95,0
24455 12 G 0,5 20 9,8 58,0 134,0 24463 12 G 0,75 19 11,4 86,0 174,0
24456 18 G 0,5 20 11,9 86,0 209,0 24464 18 G 0,75 19 14,2 130,0 261,0
24457 25 G 0,5 20 13,9 120,0 270,0 24465 25 G 0,75 19 16,3 180,0 290,0
24466 36 G 0,75 19 19,5 260,0 419,0
24467 42 G 0,75 19 21,3 302,0 614,0
Continuation
441
Cables according to international Approvals / TPE-Cables for Drag Chains UL/CSA
442
Cables according to international Approvals / TPE-Cables for Drag Chains UL/CSA
Application
The selected materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and
slow speed of movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without tensile stress or forced
movements. These robust and abrasion resistant special control cables are installed there, where the problems appear for the application in permanent
stresses e. g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent movable machinery parts for
multi-shift operation. These cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are
necessary. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high
processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please
read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
23914 2 x 0,5 20 6,4 30,0 85,0 23923 2 x 0,75 19 7,0 40,0 97,0
23915 3 G 0,5 20 6,7 36,0 99,0 23924 3 G 0,75 19 7,4 48,0 110,0
23916 4 G 0,5 20 7,3 42,0 107,0 23925 4 G 0,75 19 8,0 55,0 139,0
23917 5 G 0,5 20 7,7 48,0 140,0 23926 5 G 0,75 19 8,5 66,0 160,0
23918 7 G 0,5 20 11,3 64,0 176,0 23927 7 G 0,75 19 12,9 85,0 219,0
23919 10 G 0,5 20 10,1 80,0 204,0 23928 12 G 0,75 19 14,4 135,0 307,0
23920 12 G 0,5 20 12,4 105,0 261,0 23929 18 G 0,75 19 17,2 190,0 490,0
23921 18 G 0,5 20 14,7 137,0 360,0 23930 25 G 0,75 19 19,9 275,0 640,0
23922 25 G 0,5 20 17,1 320,0 530,0
Continuation
443
Cables according to international Approvals / TPE-Cables for Drag Chains UL/CSA
444
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA
Application
A highly-flexible PVC control cable suitable for frequent and fast lifting and bending stresses in machines and tool building, robot systems and on
constantly moving machine components. Long service lives guarantee reliable function and good cost efficiency. For applications which go beyond
standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for
our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text. Designed for machines intended for export, specifically USA and Canada.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
49885
49886
49887
2 x 0,14
3 x 0,14
4 x 0,14
26
26
26
3,7
3,9
4,1
2,8
4,1
5,6
24,0
26,0
31,0
49903
49904
49905
14 x 0,25
18 x 0,25
24 x 0,25
24
24
24
6,9
7,6
8,8
35,0
45,0
60,0
109,0
132,0
171,0
N
49888 5 x 0,14 26 4,5 7,0 36,0 49906 25 x 0,25 24 9,4 62,5 178,0
49889 7 x 0,14 26 5,1 9,8 50,0 49907 2 x 0,34 22 4,2 6,8 34,0
49890 10 x 0,14 26 5,8 14,0 65,0 49908 3 x 0,34 22 4,4 10,2 43,0
49891 12 x 0,14 26 6,0 16,8 72,0 49909 4 x 0,34 22 4,8 13,6 58,0
49892 14 x 0,14 26 6,2 19,6 78,0 49910 5 x 0,34 22 5,1 17,0 65,0
49893 18 x 0,14 26 6,9 25,2 91,0 49911 7 x 0,34 22 5,9 23,8 85,0
49894 24 x 0,14 26 7,8 33,6 120,0 49912 10 x 0,34 22 6,8 34,0 117,0
49895 25 x 0,14 26 8,3 35,0 125,0 49913 12 x 0,34 22 7,0 40,8 134,0
49896 2 x 0,25 24 4,0 5,0 29,0 49914 14 x 0,34 22 7,4 47,6 152,0
49897 3 x 0,25 24 4,2 7,5 34,0 49915 18 x 0,34 22 8,1 61,2 184,0
49898 4 x 0,25 24 4,5 10,0 40,0 49916 24 x 0,34 22 9,6 81,5 242,0
49899 5 x 0,25 24 4,9 12,5 51,0 49917 25 x 0,34 22 10,0 85,0 252,0
49900 7 x 0,25 24 5,6 17,5 65,0
49901 10 x 0,25 24 6,4 25,0 85,0
49902 12 x 0,25 24 6,6 30,1 97,0
445
Cables according to international Approvals / PVC-Cables for Drag Chains UL/CSA
Application
A highly-flexible PVC control cable suitable for frequent and fast lifting and bending stresses in machines and tool building, robot systems and on
constantly moving machine components. Long service lives guarantee reliable function and good cost efficiency. The copper screen effectively protects
against internal and external interference. Designed for machines intended for export, specifically USA and Canada. For applications which go beyond
standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for
our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
49920 2 x 0,14 26 4,3 11,3 33,0 49938 14 x 0,25 24 7,6 64,3 138,0
49921 3 x 0,14 26 4,5 14,2 36,0 49939 18 x 0,25 24 8,3 78,6 165,0
49922 4 x 0,14 26 4,7 15,5 41,0 49940 24 x 0,25 24 9,7 89,8 200,0
49923 5 x 0,14 26 5,0 18,4 46,0 49941 25 x 0,25 24 10,1 101,2 204,0
49924 7 x 0,14 26 5,7 27,9 70,0 49942 2 x 0,34 22 4,8 18,2 44,0
49925 10 x 0,14 26 6,4 39,1 88,0 49943 3 x 0,34 22 5,0 28,8 60,0
49926 12 x 0,14 26 6,7 42,2 97,0 49944 4 x 0,34 22 5,4 35,8 76,0
49927 14 x 0,14 26 6,9 45,4 105,0 49945 5 x 0,34 22 5,7 39,2 80,0
49928 18 x 0,14 26 7,6 54,2 116,0 49946 7 x 0,34 22 6,6 52,8 104,0
49929 24 x 0,14 26 8,6 66,5 150,0 49947 10 x 0,34 22 7,5 67,5 150,0
49930 25 x 0,14 26 9,0 68,5 157,0 49948 12 x 0,34 22 7,7 76,5 160,0
49931 2 x 0,25 24 4,6 14,8 39,0 49949 14 x 0,34 22 8,1 85,9 180,0
49932 3 x 0,25 24 4,8 18,9 45,0 49950 18 x 0,34 22 8,9 99,9 211,0
49933 4 x 0,25 24 5,1 21,4 52,0 49951 24 x 0,34 22 10,3 147,0 290,0
49934 5 x 0,25 24 5,5 31,2 70,0 49952 25 x 0,34 22 10,9 155,0 304,0
49935 7 x 0,25 24 6,2 39,8 80,0
49936 10 x 0,25 24 7,1 53,9 114,0
49937 12 x 0,25 24 7,3 59,2 123,0
446
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
For installation in dry, moist and wet rooms and outdoors with free movement without tensile stress or forced movements, impressively proven in
drag chain application. A highly flexible PUR control cable, suitable for frequent and quick lifting and bending stresses in machine engineering and
construction, in robot technology and on permanently moving machine components. Long service life guarantees reliable function and high
cost-efficiency. For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely
N
high processing speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays
please read the instructions. Further technical details see selection table for drag chain cables, see lead text. Attractive for export-oriented mechanical
engineering.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
49764 2 x 0,14 26 3,9 2,8 22,0 49782 14 x 0,25 24 7,4 35,0 97,0
49765 3 x 0,14 26 4,0 4,1 24,0 49783 18 x 0,25 24 8,2 45,0 114,0
49766 4 x 0,14 26 4,3 5,6 29,0 49784 24 x 0,25 24 9,6 60,0 157,0
49767 5 x 0,14 26 4,7 7,0 33,0 49785 25 x 0,25 24 10,1 62,5 160,0
49768 7 x 0,14 26 5,3 9,8 47,0 49786 2 x 0,34 22 4,6 6,8 31,0
49769 10 x 0,14 26 6,1 14,0 57,0 49787 3 x 0,34 22 4,8 10,2 38,0
49770 12 x 0,14 26 6,2 16,8 63,0 49788 4 x 0,34 22 5,2 13,6 51,0
49771 14 x 0,14 26 6,5 19,6 72,0 49789 5 x 0,34 22 5,6 17,0 54,0
49772 18 x 0,14 26 7,2 25,2 80,0 49790 7 x 0,34 22 6,5 23,8 77,0
49773 24 x 0,14 26 8,2 33,6 110,0 49791 10 x 0,34 22 7,5 34,0 104,0
49774 25 x 0,14 26 8,6 35,0 115,0 49792 12 x 0,34 22 7,7 40,8 122,0
49775 2 x 0,25 24 4,3 5,0 26,0 49793 14 x 0,34 22 8,1 47,6 140,0
49776 3 x 0,25 24 4,5 7,5 30,0 49794 18 x 0,34 22 9,2 61,2 162,0
49777 4 x 0,25 24 4,8 10,0 39,0 49795 24 x 0,34 22 10,7 81,5 204,0
49778 5 x 0,25 24 5,2 12,5 44,0 49796 25 x 0,34 22 11,2 85,0 229,0
49779 7 x 0,25 24 6,0 17,5 52,0
49780 10 x 0,25 24 6,9 25,0 70,0
49781 12 x 0,25 24 7,1 30,1 84,0
447
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
screened analogue type:
MULTISPEED-TRONIC-C-PUR,
confer page 450
Application
Application HELUKABEL MULTISPEED-TRONIC-PUR installed there, where the extreme requirements for the cables are necessary. The selected
materials and lay-up technique permit these high flexible cables for permanent application in drag chains for long distances, high and low speed of
movements. These cables are installed in dry, moist and wet rooms and in open air with free movement without tensile stress or forced movements.
These robust and abrasion resistant special control cables are installed there, where the problems appear for the application in permanent stresses
e. g. in energy drag chains, industry robotics, production lines, automatic control systems and permanent movable machinery parts for multi-shift
operation. These cables are installed everywhere, where high requirements for the flexibility, abrasion, oxygen and chemical resistance are necessary.
For applications which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing
speeds etc.) we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the
instructions. Further technical details see selection table for drag chain cables, see lead text.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24567 2 x 0,25 24 3,9 5,0 27,0 24575 2 x 0,34 22 4,1 6,8 32,0
24568 3 x 0,25 24 4,1 7,5 33,0 24576 3 x 0,34 22 4,3 10,2 40,0
24569 4 x 0,25 24 4,4 10,0 40,0 24577 4 x 0,34 22 4,6 13,6 55,0
24570 5 x 0,25 24 4,7 12,5 48,0 24578 5 x 0,34 22 5,0 17,0 60,0
24571 7 x 0,25 24 6,9 17,5 60,0 24579 7 x 0,34 22 7,3 23,8 80,0
24572 12 x 0,25 24 7,4 30,1 91,0 24580 12 x 0,34 22 7,9 40,8 127,0
24573 18 x 0,25 24 8,9 45,0 125,0 24581 18 x 0,34 22 9,7 61,2 175,0
24574 25 x 0,25 24 10,2 62,5 170,0 24582 25 x 0,34 22 10,0 85,0 238,0
448
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
Especially suited for drag chain installation in dry, moist and wet environments and outdoors with flexible movement and without tensile stress or
forced movements. A highly-flexible PVC control cable suitable for frequent and fast lifting and bending stresses in machines and tool building, robot
systems and on constantly moving machine components. Long service lives guarantee reliable function and good cost efficiency. The dense screening
N
assures interference-free transmission of all signals and impulses. An ideal interference-free control cable for the above applications. For applications
which go beyond standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we
recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions.
Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
49797 2 x 0,14 26 4,4 11,2 32,0 49815 14 x 0,25 24 8,0 64,2 135,0
49798 3 x 0,14 26 4,5 14,1 35,0 49816 18 x 0,25 24 8,8 78,4 150,0
49799 4 x 0,14 26 4,8 15,5 40,0 49817 24 x 0,25 24 10,2 89,9 194,0
49800 5 x 0,14 26 5,0 18,3 45,0 49818 25 x 0,25 24 10,7 101,0 204,0
49801 7 x 0,14 26 5,8 27,8 66,0 49819 2 x 0,34 22 5,1 18,1 45,0
49802 10 x 0,14 26 6,7 39,3 86,0 49820 3 x 0,34 22 5,3 28,7 60,0
49803 12 x 0,14 26 6,8 42,1 94,0 49821 4 x 0,34 22 5,7 35,7 76,0
49804 14 x 0,14 26 7,1 45,3 102,0 49822 5 x 0,34 22 6,1 39,1 82,0
49805 18 x 0,14 26 7,8 54,1 118,0 49823 7 x 0,34 22 7,1 52,7 110,0
49806 24 x 0,14 26 8,8 66,3 149,0 49824 10 x 0,34 22 8,1 67,4 148,0
49807 25 x 0,14 26 9,2 68,4 156,0 49825 12 x 0,34 22 8,3 76,4 166,0
49808 2 x 0,25 24 4,8 14,9 38,0 49826 14 x 0,34 22 8,7 85,5 185,0
49809 3 x 0,25 24 5,0 18,8 44,0 49827 18 x 0,34 22 9,8 99,7 216,0
49810 4 x 0,25 24 5,3 21,3 51,0 49828 24 x 0,34 22 11,3 147,1 291,0
49811 5 x 0,25 24 5,7 31,0 68,0 49829 25 x 0,34 22 11,8 155,0 305,0
49812 7 x 0,25 24 6,6 39,6 82,0
49813 10 x 0,25 24 7,5 53,9 110,0
49814 12 x 0,25 24 7,7 59,1 124,0
449
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
non screened analogue type:
MULTISPEED-TRONIC-PUR,
confer page 448
Application
For permanent application in drag chains for long distances, high and low speed of movements. These cables are installed in dry, moist and wet rooms
and in open air with free movement without tensile stress or forced movements. These robust and abrasion resistant special control cables are installed
there, where the problems appear for the application in permanent stresses. These cables are installed everywhere, where high requirements for the
flexibility, abrasion, oxygen and chemical resistance are necessary. These screened cables are particularly suitable for the interference-free transmission
in instrumentation and control engineering applications. For applications which go beyond standard solutions we recommend for our especially
developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection
table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
24614 2 x 0,25 24 5,4 74,0 39,0 24622 2 x 0,34 22 5,6 18,0 45,0
24615 3 x 0,25 24 5,6 19,0 45,0 24623 3 x 0,34 22 5,8 22,0 60,0
24616 4 x 0,25 24 5,9 22,0 51,0 24624 4 x 0,34 22 6,1 28,0 76,0
24617 5 x 0,25 24 6,2 26,0 68,0 24625 5 x 0,34 22 6,8 31,0 82,0
24618 7 x 0,25 24 8,7 35,0 83,0 24626 7 x 0,34 22 9,3 51,0 110,0
24619 12 x 0,25 24 9,4 58,0 122,0 24627 12 x 0,34 22 9,9 70,0 166,0
24620 18 x 0,25 24 11,5 79,0 160,0 24628 18 x 0,34 22 12,3 103,0 216,0
24621 25 x 0,25 24 13,0 99,0 210,0 24629 25 x 0,34 22 13,6 130,0 312,0
450
Cables according to international Approvals / PUR-Cables for Drag Chains UL/CSA
Application
Stranded in pairs, these fully-screened special drag chain cables can also be used where external, high-frequency interference influences pulse transfer.
They are used for permanently flexible stresses in machine and tool building, in robot technology, on constantly moving machine components and
for extended use in multi-shift operations. Developed to state-of-the-art technology, these highly-flexible data cable, with a cut resistant and
N
low-adhesion PUR outer sheath guaranteeing optimal service life and extremely good cost efficiency. This two-approvals single-core cable is preferred
for use in export-oriented mechanical engineering, in machine tools, production lines and systems engineering. Guaranteed extended use in multi-shift
operations with extremely high bending stresses. For applications which go beyond standard solutions we recommend for our especially developed
enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical details see selection table for
drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x AWG-No. Outer Cop. Weight Part no. No.pairs x AWG-No. Outer Cop. Weight
no.cores x app. mm weight app. no.cores x app. mm weight app.
cross-sec. kg / km kg / km cross-sec. kg / km kg / km
mm mm
49830 1 x 2 x 0,25 24 4,8 14,0 26,0 49853 6 x 2 x 0,5 20 11,8 103,0 181,0
49831 2 x 2 x 0,25 24 6,7 32,0 61,0 49854 8 x 2 x 0,5 20 14,2 148,4 274,0
49832 3 x 2 x 0,25 24 7,1 38,4 70,0 49855 10 x 2 x 0,5 20 16,5 180,0 332,0
49833 4 x 2 x 0,25 24 7,6 43,2 82,0 49856 14 x 2 x 0,5 20 16,9 218,3 390,0
49834 5 x 2 x 0,25 24 8,3 51,5 99,0 49857 1 x 2 x 0,75 19 6,2 35,2 56,0
49835 6 x 2 x 0,25 24 9,0 71,8 126,0 49858 2 x 2 x 0,75 19 9,2 61,4 102,0
49836 8 x 2 x 0,25 24 10,5 74,4 147,0 49859 3 x 2 x 0,75 19 9,8 87,1 144,0
49837 10 x 2 x 0,25 24 11,9 90,0 179,0 49860 4 x 2 x 0,75 19 11,2 95,2 160,0
49838 14 x 2 x 0,25 24 12,7 111,2 210,0 49861 5 x 2 x 0,75 19 12,2 115,0 193,0
49839 1 x 2 x 0,34 22 5,1 20,0 35,0 49862 6 x 2 x 0,75 19 13,2 137,1 216,0
49840 2 x 2 x 0,34 22 7,2 41,0 80,0 49863 8 x 2 x 0,75 19 15,6 184,4 327,0
49841 3 x 2 x 0,34 22 7,6 52,2 100,0 49864 10 x 2 x 0,75 19 18,4 259,8 451,0
49842 4 x 2 x 0,34 22 8,3 59,1 118,0 49865 14 x 2 x 0,75 19 18,9 318,4 521,0
49843 5 x 2 x 0,34 22 9,0 67,0 134,0 49866 1x2x1 18 6,7 42,0 64,0
49844 6 x 2 x 0,34 22 9,9 86,4 162,0 49867 2x2x1 18 10,0 73,0 120,0
49845 8 x 2 x 0,34 22 11,9 107,5 214,0 49868 3x2x1 18 10,8 93,6 160,0
49846 10 x 2 x 0,34 22 13,9 131,0 270,0 49869 4x2x1 18 11,7 117,8 184,0
49847 14 x 2 x 0,34 22 14,1 150,0 304,0 49870 5x2x1 18 13,2 139,0 217,0
49848 1 x 2 x 0,5 20 5,8 22,5 47,0
49849 2 x 2 x 0,5 20 8,4 53,0 100,0
49850 3 x 2 x 0,5 20 9,0 72,8 131,0
49851 4 x 2 x 0,5 20 10,0 75,6 149,0
49852 5 x 2 x 0,5 20 11,0 85,7 169,0
451
UL/CSA MOTOR, SERVO & FEEDBACK CABLES
452
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
TOPFLEX-EMV-UV-2YSLCYK-J UL/CSAMotorsupply
cable 1000 V, for power supply connections to frequency converters, double screened,
meter marking.
Note
**) The current carrying capacity for
N
permanent operation at ambient temperature
of 30C. For deviating ambient temperatures
the conversion factors should be used and
for further see the indication in
DIN VDE 0298 part 4.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
This TOPFLEX-EMV-UV-2YSLCYK-J UL/CSA motor connection cable for the frequency converters secures the EMC in systems and buildings, equipment
with devices and machineries, which can emit electromagnetic interference fields that can impact the environment in an illegal manner. It is used as
a connection and connecting cable under average mechanical stress for fixed installations and sometimes for free movement in dry, moist and wet
rooms and outside. It is used in the automotive industry, food processing industry, transfer streets, packaging industry, machine tools, handling
equipment, in the industry it is used for pumps, fans, transport belts, etc. Used in explosion proof areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. app. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight app. kg / km
mm app.nF / km app.nF / km Ohm/km Ohm/km in Amperes kg / km
22320 4 G 1,5 10,4 0 95,0 140,0 16
22321 4 G 2,5 12,5 80 130 18 210 26 150,0 300,0 14
22322 4G4 14,2 90 150 11 210 34 235,0 485,0 12
22323 4G6 15,2 90 150 6 150 44 320,0 630,0 10
22324 4 G 10 19,5 120 200 7 180 61 533,0 860,0 8
22325 4 G 16 22,9 140 230 9 190 82 789,0 1290,0 6
22326 4 G 25 27,1 120 210 4 95 108 1236,0 1860,0 4
22327 4 G 35 29,6 150 260 3 85 135 1662,0 2610,0 2
Continuation
453
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
TOPFLEX-EMV-UV-2YSLCYK-J UL/CSAMotorsupply
cable 1000 V, for power supply connections to frequency converters, double screened,
meter marking.
Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. app. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight app. kg / km
mm app.nF / km app.nF / km Ohm/km Ohm/km in Amperes kg / km
22328 4 G 50 35,2 190 320 2 40 168 2345,0 2950,0 1
22329 4 G 70 41,4 190 320 2 45 207 3196,0 3950,0 2/0
22330 4 G 95 46,0 250 410 1 50 250 4316,0 5300,0 3/0
22331 4 G 120 50,8 292 5435,0 6600,0 4/0
22332 4 G 150 58,3 335 6394,0 7040,0 300 kcmil
22333 4 G 185 65,5 382 7639,0 8380,0 350 kcmil
454
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Note
**) The current carrying capacity for
permanent operation at ambient temperature
of 30C. For deviating ambient temperatures
the conversion factors should be used and
for further see the indication in
DIN VDE 0298 part 4.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
It is used as a connection and connecting cable under average mechanical stress for fixed installation and sometimes for free movement in dry, moist
and wet rooms and outside. It is used in the automotive industry, food processing industry, transfer streets, packaging industry, machine tools, handling
equipment, in the industry it is used for pumps, fans, transport belts and in air condition systems, etc. Used in explosion proof areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
455
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
456
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Application
This UL/CSA motor power supply cable for the frequency converters assures electromagnetic compatibillity in plants and buildings, facilities with units
and operating equipment where the fields of electromagnetic interference might cause adverse effects on the surroundings. As a supply and connecting
cable for medium mechanical stresses in fixed installations and forced movements in dry, moist and wet environments. Used in the automotive and
food industries, environmental technology, packaging industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable
for use with industrial pumps, ventilators, conveyor belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
22689 3 G 1,5 9,4 72,0 200,0 16 22698 5G4 15,4 321,0 567,0 12
22690 4 G 1,5 10,4 95,0 230,0 16 22699 7G4 18,2 352,0 603,0 12
22691 5 G 1,5 11,2 117,0 258,0 16 22700 4G6 15,2 320,0 633,0 10
22692 7 G 1,5 13,2 148,0 281,0 16 22701 5G6 16,8 439,0 679,0 10
22693 3 G 2,5 11,2 137,0 270,0 14 22702 7G6 20,0 501,0 771,0 10
22694 4 G 2,5 12,5 150,0 300,0 14 22703 4 G 10 19,5 533,0 860,0 8
22695 5 G 2,5 13,5 200,0 352,0 14 22704 5 G 10 21,6 711,0 1029,0 8
22696 7 G 2,5 16,0 230,0 473,0 14 22705 4 G 16 23,1 789,0 1290,0 6
22697 4G4 14,2 235,0 485,0 12 22706 4 G 25 27,1 1236,0 1862,0 4
457
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Note
VFD = Variable Frequency Drive
Application
Flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage) and
tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures. Approved to
NFPA 79 edition 2012 for open, unprotected installation on cable trays and from cable trays to the machine. The special PVC sheath is extremly
resistant to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes and in the
earth.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Sheath colour black Sheath colour orange
Part no. No.cores Cross- Outer Cop. Weight Part no. No.cores Cross- Outer Cop. Weight
x AWG-No. section mm app. mm weight app. x AWG-No. section mm app. mm weight app.
kg / km kg / km kg / km kg / km
63139 4 x 18 0,963 9,9 52,0 164,0 63147 4 x 18 0,963 9,9 52,0 164,0
63140 4 x 16 1,31 11,4 72,0 183,0 63148 4 x 16 1,31 11,4 72,0 183,0
63137 4 x 14 2,08 12,5 118,0 197,0 63149 4 x 14 2,08 12,5 118,0 197,0
63141 4 x 12 3,31 14,0 182,0 267,0 63150 4 x 12 3,31 14,0 182,0 267,0
63142 4 x 10 5,26 17,1 256,0 402,0 63151 4 x 10 5,26 17,1 182,0 267,0
63143 4x8 8,37 22,3 417,0 668,0 63152 4x8 8,37 22,3 417,0 668,0
63144 4x6 13,31 25,4 651,0 918,0 63153 4x6 13,31 25,4 651,0 918,0
63145 4x4 21,21 30,1 910,0 1363,0 63154 4x4 21,21 30,1 910,0 1363,0
63146 4x2 33,6 35,3 1411,0 1994,0 63155 4x2 33,6 35,3 1411,0 1994,0
458
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Application
Flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage) and
tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures. Approved to
NFPA 79 edition 2012 for open, unprotected installation on cable trays and from cable trays to the machine. The special TPE sheath is extremly resistant
to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes and in the earth.
EMC = Electromagnetic compatibillity
N
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Sheath colour black
Part no. No. cores Cross- Outer Cop. Weight
x AWG-No. section mm app. mm weight app. kg / km
kg / km
63156 4x AWG 16 +2x AWG 18 1,31/ 0,963 13,0 88,0 259,0
63157 4x AWG 14 +2x AWG 18 2,08/ 0,963 14,0 133,0 370,0
63138 4x AWG 14 +2x AWG 14 2,08/ 2,08 14,0 159,0 399,0
63158 4x AWG 12 +2x AWG 18 3,31/ 0,963 15,3 197,0 435,0
63159 4x AWG 12 +2x AWG 14 3,31/ 2,08 15,7 224,0 466,0
63160 4x AWG 10 +2x AWG 14 5,26/ 2,08 18,2 301,0 703,0
63161 4x AWG 8 +2x AWG 14 8,37/ 2,08 24,1 457,0 901,0
63162 4x AWG 6 +2x AWG 14 13,31/ 2,08 27,4 615,0 1275,0
63163 4x AWG 4 +2x AWG 14 21,21/ 2,08 33,4 1450,0 1861,0
459
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Note
VFD = Variable Frequency Drive
Application
It is used as a power supply cable under average mechanical stress for fixed installation and sometimes for free movement in dry, moist wet rooms
and outside. It is used in the automotive industry, food processing industry, transfer streets, packaging industry, machine tools, handling equipment,
other industrial uses include pumps, fans, transport belts and in air conditioning systems, etc. Used in explosion proof areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No. power cores No. ground cores No. cores x Outer Cop. Weight
x AWG-No. x AWG-No. cross-section app. mm weight app. kg / km
mm kg / km
59398 3x AWG 8 + 3x AWG 16 (3x 8,37 + 3x 1,31) 17,1 372,0 573,0
59399 3x AWG 6 + 3x AWG 14 (3x 13,3 + 3x 2,08) 19,3 554,0 735,0
59400 3x AWG 4 + 3x AWG 12 (3x 21,2 + 3x 3,3) 24,5 831,0 1225,0
59401 3x AWG 2 + 3x AWG 10 (3x 33,6 + 3x 5,26) 27,8 1258,0 1737,0
59402 3x AWG 1 + 3x AWG 8 (3x 42,4 + 3x 8,37) 31,1 1615,0 2225,0
59403 3x AWG 1/0 + 3x AWG 8 (3x 53,4 + 3x 8,37) 33,1 1938,0 2604,0
59404 3x AWG 2/0 + 3x AWG 8 (3x 67,5 + 3x 8,37) 35,8 2344,0 3089,0
59405 3x AWG 3/0 + 3x AWG 6 (3x 85 + 3x 13,3) 38,6 2994,0 3823,0
59406 3x AWG 4/0 + 3x AWG 6 (3x 107,2 + 3x 13,3) 44,5 3590,0 4700,0
59407 3x AWG 250 kcmil + 3x AWG 6 (3x 127 + 3x 13,3) 48,4 4177,0 5487,0
59408 3x AWG 300 kcmil + 3x AWG 4 (3x 152 + 3x 21,2) 50,9 5104,0 6530,0
59409 3x AWG 350 kcmil + 3x AWG 2 (3x 178 + 3x 33,6) 54,0 6218,0 7768,0
59410 3x AWG 400 kcmil + 3x AWG 2 (3x 203 + 3x 33,6) 55,5 6875,0 8492,0
59411 3x AWG 500 kcmil + 3x AWG 2 (3x 254 + 3x 33,6) 60,5 8303,0 10130,0
460
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Application
This TOPFLEX-EMV-UV-2YSLC11Y-J UL/CSA motor power supply cable with PUR outher sheath for the frequency converters assures electromagnetic
compatibillity in plants and buildings, facilities with units and operating equipment where the fields of electromagnetic interference might cause
adverse effects on the surroundings. As a supply and connecting cable for medium mechanical stresses in fixed installations and forced movements
in dry, moist and wet environments and for outdoor applications. Used in the automotive and food industries, environmental technology, packaging
industry, machine tools. Handling equipment, for SIMOVERT drives, they are particularly suitable for use with industrial pumps, ventilators, conveyor
belts and air-conditioning installations and similar applications. Installation in hazardous areas.
EMC = Electromagnetic compatibillity
The screen must be connected at both ends and ensure large-area contact over the entire cable circumference for compliance with the functional
interference requirements of EN 55011.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. app. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight app. kg / km
mm app.nF / km app.nF / km Ohm/km Ohm/km in Amperes kg / km
22389 4 G 1,5 10,3 18 95,0 230,0 16
22390 4 G 2,5 12,3 80 130 18 210 26 150,0 300,0 14
22391 4G4 13,9 90 150 11 210 34 235,0 485,0 12
22392 4G6 15,3 90 150 6 150 44 320,0 630,0 10
22393 4 G 10 19,5 120 200 7 180 61 533,0 860,0 8
22394 4 G 16 23,3 140 230 9 190 82 789,0 1290,0 6
22395 4 G 25 27,4 120 211 4 95 108 1180,0 1800,0 4
22396 4 G 35 30,3 150 260 3 85 135 1662,0 2610,0 2
22397 4 G 50 35,5 190 320 2 40 168 2345,0 2950,0 1
22398 4 G 70 40,2 190 320 2 45 207 3196,0 3950,0 2/0
22399 4 G 95 44,5 250 410 1 50 250 4316,0 5300,0 3/0
22566 4 G 120 50,3 292 5435,0 6600,0 4/0
22567 4 G 150 56,1 335 6394,0 7040,0 300 kcmil
22568 4 G 185 58,0 382 7639,0 8380,0 350 kcmil
461
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Application
This TOPFLEX MOTOR EMV 1/1 two-approvals, triple-screened motor power supply cable for frequency converters provides outstanding EMC in
machines and systems. Suitable as a supply and connecting cable for high mechanical stresses, in fixed installations and occasional free movements
in dry, moist and wet environments, as well as outdoors. Areas of application include machine tools, processing and manufacturing machinery,
machining centres, industrial robots, transfer lines, handling equipment, etc.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Mutual capacitance Coupling resistance Power ratings **) Cop. Weight AWG-No.
cross-sec. app. mm Core / Core Core / Screen at 1 MHz at 30 MHz with 3 loaded cores weight app. kg / km
mm app.nF / km app.nF / km Ohm/km Ohm/km in Amperes kg / km
78377 4 G 1,5 11,5 70 110 18 95,0 230,0 16
78378 4 G 2,5 13,5 80 130 18 210 26 150,0 300,0 14
78379 4G4 15,8 90 150 11 210 34 235,0 485,0 12
78380 4G6 17,8 90 150 6 150 44 320,0 630,0 10
708609 4 G 10 21,6 120 200 7 180 61 533,0 860,0 8
708610 4 G 16 25,4 120 210 9 190 82 789,0 1290,0 6
708611 4 G 25 31,0 140 230 4 95 108 1180,0 1800,0 4
708612 4 G 35 33,0 150 260 3 85 135 1662,0 2610,0 2
78384 4 G 50 39,0 190 320 2 40 168 2345,0 2950,0 1
78385 4 G 70 45,0 190 320 2 45 207 3196,0 3950,0 2/0
78386 4 G 95 50,1 250 410 1 50 250 4316,0 5300,0 3/0
78387 4 G 120 54,2 292 5435,0 6600,0 4/0
78388 4 G 150 61,3 335 6394,0 7040,0 300 kcmil
78479 4 G 185 64,2 382 7639,0 8380,0 350 kcmil
462
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Application
This TOPFLEX MOTOR EMV 3/3 two-approvals, triple-screened motor power supply cable for frequency converters provides outstanding EMC in
machines and systems. Suitable as a supply and connecting cable for high mechanical stresses, in fixed installations and occasional free movements
in dry, moist and wet environments, as well as outdoors. Areas of application include machine tools, processing and manufacturing machinery,
machining centres, industrial robots, transfer lines, handling equipment, etc. By dividing the earth core into thirds and dividing it evenly in the interstices
between the power supply cores, a symmetrical structure has been achieved. This results in improved EMC, capacitance and inductance compared to
the 4-core version.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
463
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
464
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
TOPSERV PVC Motor and servo cables for fixed or not constantly
movements 0,6/1 kV, according to Siemens 6FX5008, Lenze, Bosch Rexroth
Note
For a corresponding encoder cables please check chapter TOPGEBER 511 PVC
For highly flexible, drag chain capable servo cables please check chapter TOPSERV PUR
Brackets ( ) indicate screen
DESINA explanation see introduction
SIEMENS product designations 6FX 5008-plus are registered trademarks of Siemens AG and are to be used only for purposes of comparison
Lenze product designations are registered trademarks of Lenze AG and are to be used only for purposes of comparison
Bosch Rexroth product designations INK are registered trademarks of Bosch Rexroth AG and are to be used only for purposes of comparison
Application
The combination of supply cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision servomotors,
as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting cables. These requirements
are met to a high degree by these cables. The cables have an additional overall screen to ensure EMC compatibility, i.e. for protection against
electromagnetic interference. Production is based on the specifications of established manufacturers of servo-drives and controls, as well as on various
VDE, UL and CSA standards.
Applications include machine, plant and robot construction, automation, drive, control and production engineering.
Attractive for export-oriented mechanical and system engineering.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
465
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
TOPSERV PVC Motor and servo cables for fixed or not constantly
movements 0,6/1 kV, according to Siemens 6FX5008, Lenze, Bosch Rexroth
TOPSERV 108 PVC, acc.to Siemens 6FX5008
Part No.cores x for OEM Sheath Outer Cop. Weight AWG-No.
no. cross-sec. system Part no. colour app. mm weight app. kg / km
mm kg / km
707250 ( 4 G 1,5) Siemens 6FX5008-1BB11 Orange RAL 2003 8,0 78,0 118,0 16
707251 ( 4 G 2,5) Siemens 6FX5008-1BB21 Orange RAL 2003 9,6 130,0 180,0 14
707252 ( 4 G 4) Siemens 6FX5008-1BB31 Orange RAL 2003 11,0 198,0 264,0 12
707253 ( 4 G 6) Siemens 6FX5008-1BB41 Orange RAL 2003 13,1 288,0 382,0 10
707254 ( 4 G 10) Siemens 6FX5008-1BB51 Orange RAL 2003 19,3 463,0 764,0 8
707255 ( 4 G 16) Siemens 6FX5008-1BB61 Orange RAL 2003 23,3 701,0 1218,0 6
707256 ( 4 G 25) Siemens 6FX5008-1BB25 Orange RAL 2003 26,9 1068,0 1670,0 4
707257 ( 4 G 35) Siemens 6FX5008-1BB35 Orange RAL 2003 30,3 1449,0 2139,0 2
707258 ( 4 G 50) Siemens 6FX5008-1BB50 Orange RAL 2003 34,5 2096,0 2991,0 1
466
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Note
For a corresponding motor- and servocables please check chapter TOPSERV PVC
For drag chain capable encoder cables please check chapter TOPGEBER 512 PUR
Brackets ( ) indicate screen.
SIEMENS product designations 6FX 5008-... are registered trademarks of Siemens AG and are to be used only for purposes of comparison.
INDRAMAT product designations INK- are registered trademarks of Bosch-Rexroth AG and are to be used only for purposes of comparison.
LENZE product designations are registered trademarks of LENZE AG, and are to be used only for purposes of comparison.
DESINA: Explanation: see introduction.
Application
Low cost alternativ to Motorcables with PUR Sheath for fix instalation or occasional moving applications. These low-capacitance incremental encoder N
cables or position feedback cables transmit the control pulses for positioning and operating characteristics of servomotors. These cables are used as
connecting cables for tachos, brakes and pulse generators in industrial equipment, machine tools, control and automation equipment.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
467
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Note
For a corresponding encoder cables please check chapter TOPGEBER 512 PUR
For servo cables with non or only slight drag chain application please check chapter TOPSERV PVC
Brackets ( ) indicate screen
DESINA explanation see introduction
SIEMENS product designations 6FX 5008-plus are registered trademarks of Siemens AG and are to be used only for purposes of comparison
Lenze product designations are registered trademarks of Lenze AG and are to be used only for purposes of comparison
Bosch Rexroth product designations INK are registered trademarks of Bosch Rexroth AG and are to be used only for purposes of comparison
Application
The combination of supply cores with the control cores for the braking function and the thermal protection in these cables is ideal. Precision servomotors,
as used today in many areas of highly-automated manufacturing processes, call for high-quality, reliable and long-lasting cables. These requirements
are met to a high degree by these cables. The cables have an additional overall screen to ensure EMC compatibillity, i. e. for protection against
electromagnetic interference. Production is based on the specifications of established manufacturers of servo-drives and controls, as well as on various
VDE, UL and CSA standards. Applications include machine, plant and robot construction, automation, drive, control and production engineering.
Attractive for export-oriented mechanical and system engineering. Please observe applicable installation regulations for use in energy supply chains.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
468
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
469
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Note
For a corresponding motor- and servocables please check chapter TOPSERV PUR
Encoder cables for static application please check chapter TOPGEBER 511 PVC
Brackets ( ) indicate screen.
SIEMENS product designations 6FX 8008-... are registered trademarks of Siemens AG and are to be used only for purposes of comparison.
Bosch Rexroth product designations INK- are registered trademarks of Bosch-Rexroth AG and are to be used only for purposes of comparison.
DESINA: Explanation: see introduction.
Application
These low-capacitance incremental encoder cables or position feedback cables transmit the control pulses for positioning and operating characteristics
of servomotors. These cables are used as connecting cables for tachos, brakes and pulse generators in applications subjected to heavy mechanical
stresses in industrial equipment, machine tools, control and automation equipment. Please observe applicable installation regulations for use in energy
supply chains.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
470
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
471
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Application
Highly-flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage)
and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures. Approved to
NFPA 79 edition 2012 for open, unprotected installation on cable trays and from cable trays to the machine. The special TPE sheath is extremly resistant
to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes and in the earth.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Sheath colour black Sheath colour orange
Part no. No.cores Cross- Outer Cop. Weight Part no. No.cores Cross- Outer Cop. Weight
x AWG-No. section mm app. mm weight app. x AWG-No. section mm app. mm weight app.
kg / km kg / km kg / km kg / km
62607 4 x 18 0,963 9,9 38,0 163,0 62616 4 x 18 0,963 9,9 38,0 163,0
62608 4 x 16 1,31 11,4 51,0 184,0 62617 4 x 16 1,31 11,4 51,0 184,0
62609 4 x 14 2,08 12,5 80,0 197,0 62618 4 x 14 2,08 12,5 80,0 197,0
62610 4 x 12 3,31 14,0 127,0 266,0 62619 4 x 12 3,31 14,0 127,0 266,0
62611 4 x 10 5,26 17,1 230,0 401,0 62620 4 x 10 5,26 17,1 230,0 401,0
62612 4x8 8,37 22,3 384,0 669,0 62621 4x8 8,37 22,3 384,0 669,0
62613 4x6 13,31 25,4 614,0 917,0 62622 4x6 13,31 25,4 614,0 917,0
62614 4x4 21,21 30,1 960,0 1364,0 62623 4x4 21,21 30,1 960,0 1364,0
62615 4x2 33,6 35,3 1344,0 1990,0 62624 4x2 33,6 35,3 1344,0 1990,0
472
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
Application
Highly flexible, extremly oil-resistant motor supply cable for modern servomotors; the double-screening with special aluminium foil (100% coverage)
and tinned copper braid (approx. 85% coverage) provides effective protection against electrical disturbance and the resultant failures. Approved to
NFPA 79 edition 2012 for open, unprotected installation on cable trays and from cable trays to the machine. The special TPE sheath is extremly resistant
to oil, coolants and solvents and hence the perfect solution for industrial applications with open installation, installation in pipes and in the earth.
N
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Sheath colour black
Part no. No. cores Cross- Outer Cop. Weight
x AWG-No. section mm app. mm weight app. kg / km
kg / km
59837 4x AWG 16 +2x AWG 18 1,31/ 0,824 13,0 88,0 259,0
59838 4x AWG 14 +2x AWG 18 2,08/ 0,824 14,0 133,0 370,0
59839 4x AWG 14 +2x AWG 14 2,08/ 2,08 14,6 159,0 399,0
59840 4x AWG 12 +2x AWG 18 3,31/ 0,824 15,3 197,0 435,0
59841 4x AWG 12 +2x AWG 14 3,31/ 2,08 15,7 224,0 466,0
59842 4x AWG 10 +2x AWG 14 5,26/ 2,08 18,2 301,0 703,0
59843 4x AWG 8 +2x AWG 14 8,37/ 2,08 24,1 457,0 901,0
59844 4x AWG 6 +2x AWG 14 13,31/ 2,08 27,4 615,0 1275,0
59845 4x AWG 4 +2x AWG 14 21,21/ 2,08 33,4 1450,0 1861,0
473
Cables according to international Approvals / Motor, Feedback and Servo Cables UL/CSA
feedback systems
Note
The technical data for TOPSERV Hybrid PVC cables are available on request.
Application
The supply conductors for these cables are ideally combined with the control conductors for the brake function and the transmission of the Sick
Hiperface DSL protocols. Applications include machine, plant and robot construction. Please observe applicable installation regulations for use in
energy supply chains.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPSERV Hybrid PVC for fixed or not constantly movements
Part No.cores x Sheath Outer Cop. Weight AWG-No.
no. cross-sec. colour app. mm weight app. kg / km
mm kg / km
709930 (4G0,5 + (2x0,34) C + (2x26 AWG)) C Orange RAL 2003 9,3 72,0 123,0 26
709932 (4G1 + (2x0,75) C + (2x22 AWG)) C Orange RAL 2003 11,6 130,0 208,0 22
709933 (4G1,5 + (2x0,75) C + (2x22 AWG)) C Orange RAL 2003 12,2 152,0 248,0 22
709934 (4G2,5 + (2x1) C + (2x22 AWG)) C Orange RAL 2003 13,8 207,0 326,0 22
709935 (4G4 + (2x1) C + (2x22 AWG)) C Orange RAL 2003 15,3 273,0 415,0 22
709936 (4G6 + (2x1) C + (2x22 AWG)) C Orange RAL 2003 17,2 357,0 538,0 22
709937 (4G10 + (2x1,5) C + (2x22 AWG)) C Orange RAL 2003 20,3 530,0 752,0 22
709938 (4G16 + (2x1,5) C + (2x22 AWG)) C Orange RAL 2003 22,6 768,0 1005,0 22
474
UL/CSA HEAT-RESISTANT CABLES
Cables according to international Approvals / Heat resistant Cables UL/CSA
Note
G = with green-yellow conductor
x = without green-yellow conductor
screened analogue type:
SiHF-C-Si UL/CSA , confer page 478
Application
UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. They are heat-resistant for
permanent temperature up to +180C, for short time operation up to +220C. The good performance of the environmental resistant properties means
that silicone cables can be used at temperatures down to -60C. Silicone cables are halogen-free cables and are especially suited for installation in
power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement
factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
23214 2 x 0,5 20 7,7 9,6 73,0 23226 2x1 18 8,2 19,2 88,0
23215 3 G 0,5 20 8,1 14,4 82,0 23227 3G1 18 9,0 28,2 111,0
23216 4 G 0,5 20 8,8 19,2 98,0 23228 4G1 18 10,0 38,4 130,0
23217 5 G 0,5 20 9,4 24,0 120,0 23229 5G1 18 10,6 48,0 161,0
23218 6 G 0,5 20 10,4 28,8 131,0 23230 6G1 18 11,4 57,6 182,0
23219 7 G 0,5 20 10,4 33,6 140,0 23231 7G1 18 11,4 67,2 198,0
23220 8 G 0,5 20 10,8 38,4 183,0 23232 8G1 18 12,4 76,8 251,0
23221 10 G 0,5 20 12,8 48,0 201,0 24010 9G1 18 13,2 86,0 277,0
23222 12 G 0,5 20 13,4 57,6 241,0 23233 10 G 1 18 13,2 96,0 304,0
23223 16 G 0,5 20 13,9 76,8 269,0 23234 12 G 1 18 14,4 115,2 343,0
23224 18 G 0,5 20 14,4 86,4 311,0 23235 16 G 1 18 15,7 153,6 441,0
23225 25 G 0,5 20 16,8 120,0 401,0 23236 18 G 1 18 16,6 172,8 492,0
23237 25 G 1 18 19,1 240,0 617,0
Continuation
476
Cables according to international Approvals / Heat resistant Cables UL/CSA
477
Cables according to international Approvals / Heat resistant Cables UL/CSA
Application
UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of
the environmental resistant properties means that silicone cables can be used at temperatures down to -60C. Silicone cables are halogen-free cables
and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship
building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable.
An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore
flexible cable for such applications as given above.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
22637 2 x 0,5 20 9,0 55,5 94,0 22656 10 G 1,5 16 17,3 268,5 478,0
22638 3 G 0,5 20 9,3 60,8 104,0 22657 12 G 1,5 16 17,9 298,4 521,0
22639 4 G 0,5 20 9,7 66,5 125,0 22658 2 x 2,5 14 12,0 122,3 226,0
22640 5 G 0,5 18 10,1 81,6 149,0 22659 3 G 2,5 14 12,7 147,7 271,0
22641 7 G 0,5 20 10,5 92,2 168,0 22660 4 G 2,5 14 14,0 188,6 332,0
22642 10 G 0,5 20 13,2 124,0 237,0 22661 5 G 2,5 14 15,1 214,9 384,0
22643 12 G 0,5 20 13,4 134,4 260,0 22662 7 G 2,5 14 16,9 265,7 478,0
22644 2x1 18 9,5 66,7 130,0 22663 4G4 12 17,0 294,0 516,0
22645 3G1 18 9,6 86,2 151,0 22664 5G4 12 19,1 374,0 641,0
22646 4G1 18 10,6 96,8 169,0 22665 4G6 10 18,6 449,0 773,0
22647 5G1 18 11,6 108,3 198,0 22666 5G6 10 21,3 563,0 980,0
22648 7G1 18 12,1 141,2 236,0 22667 4 G 10 8 25,5 759,0 1284,0
22649 10 G 1 18 14,7 190,0 248,0
22650 12 G 1 18 15,1 209,8 364,0
22651 2 x 1,5 16 10,6 87,7 169,0
22652 3 G 1,5 16 11,0 103,5 191,0
22653 4 G 1,5 16 11,6 131,7 230,0
22654 5 G 1,5 16 13,1 148,5 272,0
22655 7 G 1,5 16 14,1 193,4 341,0
478
UL/CSA ALLWEATHER CABLES & RUBBER CABLES
Cables according to international Approvals / Allweather and Rubber Cables UL/CSA
Application
As a flexible cord for mobile equipment for use in rougher conditions in the engines and mechanical engineering, dockyards, in agriculture, in cabins
and steel rolling mills and for export overseas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Nominal voltage 300 Volt, type SJO (90C)
Part no. No.cores Current Cond. make-up Outer Weight
x AWG-No. carrying n x wire app. mm app. kg / km
capacity
in Amp.
63010 2 x 18 7 16 x 0,3 7,8 65,0
63011 3 x 18 7 16 x 0,3 8,4 80,0
63012 4 x 18 7 16 x 0,3 9,2 95,0
63013 2 x 16 10 26 x 0,3 8,3 130,0
63014 3 x 16 10 26 x 0,3 9,0 148,0
63015 4 x 16 10 26 x 0,3 10,0 180,0
63016 2 x 14 15 41 x 0,3 9,4 195,0
63017 3 x 14 15 41 x 0,3 10,0 225,0
63018 4 x 14 15 41 x 0,3 10,7 288,0
480
Cables according to international Approvals / Allweather and Rubber Cables UL/CSA
Application
Highly-standardised, heavy-duty rubber-sheated cable for use in practically all machines destined for export markets, in dry, damp, wet environments
and outdoors. As a feeder to transportable motors or machines, cranes, hoists, hand lamps and drilling machines.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part Cross- No.cores Current carrying Outer Cop. Weight Part Cross- No.cores Current carrying Outer Cop. Weight
no. section x capacity in ampere app. weight app. no. section x capacity in ampere app. weight app.
mm AWG-No. at 30C ambient mm kg / km kg / km mm AWG-No. at 30C ambient mm kg / km kg / km
temperature temperature
39025 1 3 x 17 10 9,6 29,0 130,0 39033 4 4 x 11 20 17,3 154,0 395,0
39026 1,5 3 x 15 13 10,2 43,0 165,0 39034 4 5 x 11 16 18,7 192,0 485,0
39027 1,5 4 x 15 10 11,4 58,0 200,0 39035 6 3 x 9 30 17,1 173,0 420,0
N
39028 1,5 5 x 15 8 13,1 72,0 240,0 39036 6 4 x 9 25 18,4 230,0 540,0
39029 2,5 3 x 13 18 14,0 72,0 235,0 39037 6 5 x 9 24 20,1 288,0 650,0
39030 2,5 4 x 13 15 15,1 96,0 290,0 39038 10 3 x 7 40 22,9 288,0 810,0
39031 2,5 5 x 13 12 16,9 120,0 345,0 39039 10 4 x 7 35 25,0 384,0 950,0
39032 4 3 x 11 25 16,0 115,0 320,0
481
UL/CSA REELING CABLES
482
Cables according to international Approvals / Trailing Cables UL/CSA
Application
Significantly smaller external diameters, smaller bending radii and reduced weights compared to NSHTU cables enable the use of smaller drive motors
and drums, thus providing significant cost savings. Trailing cables are used for high mechanical stress, especially for applications with frequent winding
and unwinding with simultaneous tensile and torsional stress, for building machinery, conveyors and lifting systems, and cranes. They are used as
robust and all-weather resistant cables in the harshest operating environments in mining and in flexible handling equipment and railway motors. The
cables are suitable for installation in dry, damp and wet environments, as well as outdoors.
Notes
During installation and operation the tensile stress on the cable must not exceed 25 N/mm
Acceleration must not exceed 0,4 m/s
1 to 2 turns should remain on the drum during operation
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
483
UL/CSA SINGLE CORES
484
Cables according to international Approvals / Single Conductors UL/CSA
Application
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. Connecting wires in machines
laid in protective tubes and flexible pipes and also for motors and transformators.
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
635xx 1 x 0,13 26 1,4 1,6 3,2 624xx 1 x 1,32 16 2,4 13,0 18,5
620xx 1 x 0,21 24 1,5 2,3 4,3 636xx 1 x 2,08 14 3,0 20,0 29,0
621xx 1 x 0,33 22 1,6 3,4 6,0 637xx 1 x 3,31 12 3,9 33,0 40,0
622xx 1 x 0,52 20 1,8 5,3 8,5 638xx 1 x 5,26 10 4,1 51,6 61,0
623xx 1 x 0,82 18 2,1 8,2 12,5
485
Cables according to international Approvals / Single Conductors UL/CSA
Application
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. Connecting wires in machines
laid in protective tubes and flexible pipes and also for motors and transformators.
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
660xx 1 x 0,13 26 1,4 1,6 3,2 665xx 1 x 1,32 16 2,4 13,0 18,5
661xx 1 x 0,21 24 1,5 2,3 4,3 666xx 1 x 2,08 14 2,9 20,0 29,0
662xx 1 x 0,33 22 1,6 3,4 6,0 667xx 1 x 3,31 12 3,6 33,0 40,0
663xx 1 x 0,52 20 1,8 5,3 8,5 668xx 1 x 5,26 10 4,3 51,6 61,0
664xx 1 x 0,82 18 2,1 8,2 12,5
486
Cables according to international Approvals / Single Conductors UL/CSA
Application
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. Connecting wires in machines
laid in predective tubes and flexible pipes and also for motors and transformators. UL bzw. CSA:
AWM = Appliance Wiring Material N
For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components.
UL-MTW: Machine Tool Wires
CSA-TEW: Equipment Lead Wires
MTW = Machine Tool Wire
For the electronical installation of machine tools and the relative control.
UL = Underwriters Laboratories Inc. (USA)
CSA = Canadian Standards Association (Canada)
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
601xx 1 x 0,21 24 2,2 2,3 8,0 613xx 1 x 33,61 2 11,3 317,0 380,0
602xx 1 x 0,33 22 2,4 3,2 10,0 614xx 1 x 42,38 1 13,3 399,0 500,0
603xx 1 x 0,52 20 2,5 5,0 12,0 615xx 1 x 53,47 1/0 13,6 500,0 615,0
604xx 1 x 0,81 18 2,8 7,9 16,0 616xx 1 x 67,4 2/0 15,5 631,0 750,0
605xx 1 x 1,31 16 3,1 12,6 22,0 617xx 1 x 84,97 3/0 17,5 792,0 900,0
606xx 1 x 2,08 14 3,5 20,7 31,0 618xx 1 x 107,17 4/0 19,0 996,0 1070,0
607xx 1 x 3,32 12 4,0 33,0 45,0 62501 1 x 127 250 kcmil 21,2 1178,0 1280,0
608xx 1 x 5,26 10 4,6 51,6 65,0 62601 1 x 152 300 kcmil 22,4 1410,0 1518,0
609xx 1 x 8,35 8 6,5 80,6 110,0 62701 1 x 178 350 kcmil 25,3 1645,0 1756,0
610xx 1 x 13,29 6 8,0 125,0 175,0 62801 1 x 203 400 kcmil 26,0 1902,0 2002,0
611xx 1 x 21,14 4 9,5 201,0 260,0 62901 1 x 254 500 kcmil 28,0 2345,0 2475,0
612xx 1 x 26,65 3 10,4 253,0 340,0
487
Cables according to international Approvals / Single Conductors UL/CSA
Application
Three norms approved connecting jumper wire primarily designed for exportes, used in machine tools. This wire is used for internal wiring of switchboards
and electrical equipment. The approbation of HAR-UL-CSA AWM make possible an economical storekeeping and simplification of parts list.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05V-K
Cross-sec. Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
mm app. mm weight
/ AWG-no. kg / km
app. RAL 9005 - 5015 8003 3000 1013 7000 4005 1021 3015 6018 - 5010 2003 - -
Part no. 63815 63816 63817 63818 63819 63820 63821 63822 63823 63824 63825 63826 63827 63828 63829 63830
0,5 / 20 2,5 4,8
Part no. 63831 63832 63833 63834 63835 63836 63837 63838 63839 63840 63841 63842 63843 63844 63845 63846
0,75 / 19 2,65 7,2
Part no. 63847 63848 63849 63850 63851 63852 63853 63854 63855 63856 63857 63858 63859 63860 63861 63862
1 / 18 2,8 9,6
Continuation
488
Cables according to international Approvals / Single Conductors UL/CSA
489
Cables according to international Approvals / Single Conductors UL/CSA
Application
Five norms approved connecting jumper wire primarily designed for exportes, used in machine tools. The approbation of HAR, UL-AWM, UL-MTW,
CSA-AWM, CSA-Equipment-wire make possible an economical storekeeping and simplification of parts list.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
H05V2-K
Cross-sec. Outer Cop. BK GN-YE BU BN RD WH GY VT YE PK GN TRANS D-BU OG o.col. 2-col.
mm app. mm weight
/ AWG-no. kg / km
app. RAL 9005 - 5015 8003 3000 1013 7000 4005 1021 3015 6018 - 5010 2003 - -
Part no. 64075 64076 64077 64078 64079 64080 64081 64082 64083 64084 64085 64086 64087 64088 64089 64090
0,5 / 22 2,65 5,2
Part no. 64091 64092 64093 64094 64095 64096 64097 64098 64099 64100 64101 64102 64103 64104 64105 64106
0,75 / 20 2,6 7,2
Part no. 64107 64108 64109 64110 64111 64112 64113 64114 64115 64116 64117 64118 64119 64120 64121 64122
1 / 18 2,8 9,6
Continuation
490
Cables according to international Approvals / Single Conductors UL/CSA
Continuation
491
Cables according to international Approvals / Single Conductors UL/CSA
492
Cables according to international Approvals / Single Conductors UL
Application
As flexible connecting cable in machines, switch and distribution cabinets, cable assemblies and for fixed indoor installation, in tubes and in cable
conduits.
AWM = Appliance Wiring Material
For internal wrings for electrical equipment and control apparatus e. g. radio and televisions, electronic assembly component. N
MTW = Machine Tool Wire
For the electronical installation of machine tools and the relative control. THW = Thermoplastic PVC-insulated building wire, Heat resistant 75C, for
Wet and dry locations, flame retardant. THHN = Thermoplastic PVC-insulated building wire, Nylon sheathed, 90C 600 V, for dry and damp locations.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
493
Cables according to international Approvals / Single Conductors
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
As hook up wire, control cabinet building, in cable assembly manufacturing as well as in electronic applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
494
Cables according to international Approvals / Single Conductors UL/CSA
Application
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systems
and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation ducts, as well as for
traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks. These halogen-free single core N
cables are characterised by their amazingly hight long-time resistance to temperature and feature among the leading halogen-free. Flame resistant
products in the world.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
495
Cables according to international Approvals / Single Conductors UL/CSA
Application
These temperature resistant single-core cables are used for the internal wiring of lighting fixtures, heaters, electrical machinery, switching systems
and distributors in equipment and plant and machinery, suitable for installation on, in and beneath plaster, in closed installation ducts, as well as for
traffic systems and outdoor applications. These cables are not approved for direct routing on racks, gutters or tanks. These halogen-free single core
cables are characterised by their amazingly high long-time resistance to temperature and feature among the leading halogen-free, flame resistant
products in the world.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
496
Cables according to international Approvals / Single Conductors UL
Note
Additional sizes on request.
Application
UL-approved single cores for use in high, temperature areas. They are used mainly in the steel producing industries, in aviation industries as well as
in ship building, cement, glas and ceramic factories
AWM = Appliance Wiring Material
For internal wirings for electrical equipment and control apparatus e. g. electronic assembly components
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no.
24 1 x 0,5 2,1
kg / km
1,9 6,3
47021
o. r.
47022
o. r.
47023
o. r.
47024
o. r.
47025
o. r.
47026
o. r.
47027
o. r.
47076
o. r.
N
Part no. 47028 47029 47030 47031 47032 47033 47034 47071
22 3 x 0,4 2,4 3,6 9,2 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
Part no. 47035 47036 47037 47038 47039 47040 47041 47072
20 5 x 0,4 2,6 6,0 12,3 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
Part no. 47042 47043 47044 47045 47046 47047 47048 47073
18 7 x 0,4 2,8 8,6 15,5 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
Part no. 47049 47050 47051 47052 47053 47054 47055 47074
16 11 x 0,4 3,0 13,3 21,0 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
Part no. 47056 47057 47058 47059 47060 47061 47062 47075
14 17 x 0,4 3,4 20,5 29,7 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
Part no. 47063 47064 47065 47066 47067 47068 47069 47070
12 27 x 0,4 3,8 32,6 43,2 o. r. o. r. o. r. o. r. o. r. o. r. o. r. o. r.
497
Cables according to international Approvals / Single Conductors UL/CSA
Application
PVC Single cores suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements
in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial- or as underwater cable. These two norms
approved single cores designed for exportorientated machinery manufacturer for machine tools, conveyor belts and production lines.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Core Outer Cop. Weight Part no. No.cores x AWG-No. Core Outer Cop. Weight
cross-sec. colour app. weight app. cross-sec. colour app. weight app.
mm mm kg / km kg / km mm mm kg / km kg / km
10881 1G6 10 green-yellow 7,8 58,0 118,0 10893 1 G 70 2/0 green-yellow 17,9 672,0 910,0
10882 1x6 10 black 7,8 58,0 118,0 10894 1 x 70 2/0 black 17,9 672,0 910,0
10883 1 G 10 8 green-yellow 9,0 96,0 180,0 10895 1 G 95 3/0 green-yellow 19,5 912,0 1195,0
10884 1 x 10 8 black 9,0 96,0 180,0 10896 1 x 95 3/0 black 19,5 912,0 1195,0
10885 1 G 16 6 green-yellow 10,0 154,0 250,0 10897 1 G 120 4/0 green-yellow 22,3 1152,0 1545,0
10886 1 x 16 6 black 10,0 154,0 250,0 10898 1 x 120 4/0 black 22,3 1152,0 1545,0
10887 1 G 25 4 green-yellow 11,5 240,0 370,0 10899 1 G 150 250 kcmil green-yellow 25,0 1440,0 1750,0
10888 1 x 25 4 black 11,5 240,0 370,0 10900 1 x 150 250 kcmil black 25,0 1440,0 1750,0
10889 1 G 35 2 green-yellow 13,0 336,0 490,0 10901 1 G 185 350 kcmil green-yellow 28,6 1776,0 2320,0
10890 1 x 35 2 black 13,0 336,0 490,0 10902 1 x 185 350 kcmil black 28,6 1776,0 2320,0
10891 1 G 50 1 green-yellow 15,6 480,0 665,0 10903 1 G 240 450 kcmil green-yellow 31,4 2304,0 2960,0
10892 1 x 50 1 black 15,6 480,0 665,0 10904 1 x 240 450 kcmil black 31,4 2304,0 2960,0
498
Cables according to international Approvals / Single Conductors UL/CSA
Application
PVC single cores suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements
in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burrial-or as underwater cable. These two norms
approved single cores designed for exportorientated machinery manufacturer for machine tools, conveyor belts and production lines. These screened N
cables are particulary suitable for the interference-free transmission in instrumentation and control engineering applications (electromagnetic
compatibillity).
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Core Outer Cop. Weight Part no. No.cores x AWG-No. Core Outer Cop. Weight
cross-sec. colour app. weight app. cross-sec. colour app. weight app.
mm mm kg / km kg / km mm mm kg / km kg / km
10910 1G6 10 green-yellow 7,6 72,0 140,0 10922 1 G 70 2/0 green-yellow 17,4 780,0 1090,0
10911 1x6 10 black 7,6 72,0 140,0 10923 1 x 70 2/0 black 17,4 780,0 1090,0
10912 1 G 10 8 green-yellow 9,4 130,0 230,0 10924 1 G 95 3/0 green-yellow 20,1 1030,0 1395,0
10913 1 x 10 8 black 9,4 130,0 230,0 10925 1 x 95 3/0 black 20,1 1030,0 1395,0
10914 1 G 16 6 green-yellow 10,4 190,0 300,0 10926 1 G 120 4/0 green-yellow 23,0 1285,0 1770,0
10915 1 x 16 6 black 10,4 190,0 300,0 10927 1 x 120 4/0 black 23,0 1285,0 1770,0
10916 1 G 25 4 green-yellow 12,0 260,0 420,0 10928 1 G 150 250 kcmil green-yellow 26,1 1570,0 1930,0
10917 1 x 25 4 black 12,0 260,0 420,0 10929 1 x 150 250 kcmil black 26,1 1570,0 1930,0
10918 1 G 35 2 green-yellow 14,4 405,0 615,0 10930 1 G 185 350 kcmil green-yellow 29,3 1940,0 2635,0
10919 1 x 35 2 black 14,4 405,0 615,0 10931 1 x 185 350 kcmil black 29,3 1940,0 2635,0
10920 1 G 50 1 green-yellow 16,4 560,0 825,0 10932 1 G 240 450 kcmil green-yellow 32,2 2530,0 3380,0
10921 1 x 50 1 black 16,4 560,0 825,0 10933 1 x 240 450 kcmil black 32,2 2530,0 3380,0
499
Cables according to international Approvals / Single Conductors UL/CSA
TOPFLEX 302 / 302-UL very high flexible PVC single core double
insulated 0,6/1kV
Application
These cables are specially designed for use as connecting cables on sliding contacts for current collectors, and also for use in energy supply chains,
automatic handling devices, robots, machine tools, machining and processing equipment, and nearly any area requiring flexible used and free motion.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX 302 without UL-approval TOPFLEX 302 with UL-approval
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
72946 1 x 1,5 16 4,0 14,4 25,0 700231 1 x 1,5 16 5,2 14,4 25,0
73924 1 x 2,5 14 4,5 24,0 42,0 700232 1 x 2,5 14 6,4 24,0 42,0
72950 1x4 12 5,6 38,4 58,0 700233 1x4 12 7,0 38,4 58,0
72945 1x6 10 6,1 57,6 85,0 700234 1x6 10 7,5 57,6 85,0
75450 1 x 10 8 8,0 96,0 130,0 701351 1 x 10 8 9,1 96,0 130,0
72947 1 x 16 6 9,8 153,6 190,0 700114 1 x 16 6 10,8 153,6 190,0
75451 1 x 25 4 11,8 240,0 280,0 701352 1 x 25 4 13,1 240,0 280,0
75452 1 x 35 2 12,9 336,0 400,0 701353 1 x 35 2 14,1 336,0 400,0
75453 1 x 50 1 14,6 480,0 520,0 701354 1 x 50 1 15,8 480,0 520,0
72944 1 x 70 2/0 17,5 672,0 720,0 700235 1 x 70 2/0 19,0 672,0 720,0
75454 1 x 95 3/0 20,2 912,0 1050,0 701355 1 x 95 3/0 21,5 912,0 1050,0
75455 1 x 120 4/0 21,6 1152,0 1220,0 701356 1 x 120 4/0 23,2 1152,0 1220,0
75456 1 x 150 300 kcmil 23,5 1440,0 1500,0 701357 1 x 150 300 kcmil 25,2 1440,0 1500,0
75457 1 x 185 350 kcmil 25,7 1776,0 1940,0 701358 1 x 185 350 kcmil 27,0 1776,0 1940,0
75458 1 x 240 500 kcmil 29,5 2304,0 2675,0 701359 1 x 240 500 kcmil 31,5 2304,0 2675,0
500
Cables according to international Approvals / Single Conductors UL/CSA
Single 602-RC -J/O special single core cable for drag chains,
90C, 600 V, meter marking
Application
High flexible special single core cable for drag chains are used for flexible use for medium mechanical stresses with free movement without tensile
stress or forced movements in dry, moist and wet rooms. These two-norm cables primarily designed for exportorientated machinery manufacturer
for flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts. For applications which go beyond
N
standard solutions (for example for composting appliances or high shelf conveyors with extremely high processing speeds etc.) we recommend for
our especially developed enquiry sheet for energy guiding systems. Before installation in cable trays please read the instructions. Further technical
details see selection table for drag chain cables, see lead text.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Core Outer Cop. Weight Part no. No.cores x AWG-No. Core Outer Cop. Weight
cross-sec. colour app. weight app. cross-sec. colour app. weight app.
mm mm kg / km kg / km mm mm kg / km kg / km
69601 1 G 10 8 green-yellow 9,4 96,0 180,0 69613 1 G 95 3/0 green-yellow 20,5 912,0 1195,0
69602 1 x 10 8 black 9,4 96,0 180,0 69614 1 x 95 3/0 black 20,5 912,0 1195,0
69603 1 G 16 6 green-yellow 10,5 154,0 250,0 69615 1 G 120 4/0 green-yellow 23,0 1152,0 1545,0
69604 1 x 16 6 black 10,5 154,0 250,0 69616 1 x 120 4/0 black 23,0 1152,0 1545,0
69605 1 G 25 4 green-yellow 11,6 240,0 370,0 69617 1 G 150 250 kcmil green-yellow 25,2 1440,0 1750,0
69606 1 x 25 4 black 11,6 240,0 370,0 69618 1 x 150 250 kcmil black 25,2 1440,0 1750,0
69607 1 G 35 2 green-yellow 14,5 336,0 490,0 69619 1 G 185 350 kcmil green-yellow 29,0 1776,0 2320,0
69608 1 x 35 2 black 14,5 336,0 490,0 69620 1 x 185 350 kcmil black 29,0 1776,0 2320,0
69609 1 G 50 1 green-yellow 16,6 480,0 665,0 69621 1 G 240 450 kcmil green-yellow 32,5 2304,0 2960,0
69610 1 x 50 1 black 16,6 480,0 665,0 69622 1 x 240 450 kcmil black 32,5 2304,0 2960,0
69611 1 G 70 2/0 green-yellow 18,4 672,0 910,0 69623 1 G 300 550 kcmil green-yellow 35,4 2880,0 3550,0
69612 1 x 70 2/0 black 18,4 672,0 910,0 69624 1 x 300 550 kcmil black 35,4 2880,0 3550,0
501
Cables according to international Approvals / Single Conductors UL/CSA
Application
High flexible special single core screened cables for drag chains are used for flexible use for medium mechanical stresses with free movement without
tensile stress or forced movements in dry, moist and wet rooms. These two-norm cables primarily designed for exportorientated machinery manufacturer
for flexible applications in machineries, machine tools, robot technics, for movable automated machinery parts. These screened cables are particulary
suitable for the interference-free transmission in instrumentation and control engineering applications (electromagnetic compatibillity). For applications
which go beyond standard solutions we recommend for our especially developed enquiry sheet for energy guiding systems. Before installation in cable
trays please read the instructions. Further technical details see selection table for drag chain cables, see lead text.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
RC = Robotics Cable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
69631 1 G 10 8 10,0 130,0 230,0 69643 1 G 95 3/0 22,0 1030,0 1395,0
69632 1 x 10 8 10,0 130,0 230,0 69644 1 x 95 3/0 22,0 1030,0 1395,0
69633 1 G 16 6 11,1 190,0 300,0 69645 1 G 120 4/0 23,6 1285,0 1770,0
69634 1 x 16 6 11,1 190,0 300,0 69646 1 x 120 4/0 23,6 1285,0 1770,0
69635 1 G 25 4 12,3 260,0 420,0 69647 1 G 150 250 kcmil 25,8 1570,0 1930,0
69636 1 x 25 4 12,3 260,0 420,0 69648 1 x 150 250 kcmil 25,8 1570,0 1930,0
69637 1 G 35 2 15,1 405,0 615,0 69649 1 G 185 350 kcmil 29,8 1940,0 2635,0
69638 1 x 35 2 15,1 405,0 615,0 69650 1 x 185 350 kcmil 29,8 1940,0 2635,0
69639 1 G 50 1 17,2 560,0 825,0 69651 1 G 240 450 kcmil 33,5 2530,0 3380,0
69640 1 x 50 1 17,2 560,0 825,0 69652 1 x 240 450 kcmil 33,5 2530,0 3380,0
69641 1 G 70 2/0 19,0 780,0 1090,0 69653 1 G 300 550 kcmil 36,2 3140,0 4120,0
69642 1 x 70 2/0 19,0 780,0 1090,0 69654 1 x 300 550 kcmil 36,2 3140,0 4120,0
502
Cables according to international Approvals / Single Conductors UL/CSA
Application
Thanks to their outstanding alternating bending stress characteristics, these cables are ideally suited for use in drag chains, and also for use in handling
devices, robots, and nearly any area requiring flexible used and free motion.
TOPFLEX 304-C Optimum compliance with requirements for electromagnetic compatibillity (EMC) by approx. 85% coverage from the braided
screen.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX 304 TOPFLEX 304C
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
79639 1 G 2,5 14 4,5 24,0 42,0 79653 1 G 2,5 14 5,9 40,0 55,0
79640 1G4 12 5,6 38,4 58,0 79654 1G4 12 6,5 50,0 75,0
79641 1G6 10 6,1 57,6 85,0 79655 1G6 10 8,3 88,0 125,0
71544
79642
79643
1 G 10
1 G 16
1 G 25
8
6
4
8,0
9,8
11,8
96,0
154,0
240,0
130,0
190,0
280,0
79656
79657
79658
1 G 10
1 G 16
1 G 25
8
6
4
8,7
10,3
12,4
124,0
190,0
260,0
170,0
300,0
420,0
N
79644 1 G 35 2 12,9 336,0 400,0 79659 1 G 35 2 13,7 405,0 620,0
79645 1 G 50 1 14,6 480,0 520,0 79660 1 G 50 1 15,4 560,0 825,0
79646 1 G 70 2/0 17,5 672,0 720,0 79661 1 G 70 2/0 17,5 780,0 1090,0
79647 1 G 95 3/0 20,0 912,0 1050,0 79662 1 G 95 3/0 21,0 1030,0 1395,0
79648 1 G 120 4/0 21,6 1152,0 1220,0 79685 1 G 120 4/0 22,4 1311,0 1770,0
79649 1 G 150 300 kcmil 23,5 1440,0 1500,0 79663 1 G 150 300 kcmil 24,3 1527,0 1930,0
79650 1 G 185 350 kcmil 25,7 1776,0 1940,0 79664 1 G 185 350 kcmil 26,5 1940,0 2635,0
79651 1 G 240 500 kcmil 29,5 2304,0 2675,0 79665 1 G 240 500 kcmil 30,3 2530,0 3380,0
79652 1 G 300 600 kcmil 32,5 2880,0 3300,0 79666 1 G 300 600 kcmil 35,0 3050,0 3500,0
503
Cables according to international Approvals / Single Conductors UL/CSA
Application
These special drag chain core cables permit extended use with extreme requirements, with free movement, without tensile stresses or forced movements.
Suitable for installation in long traverse paths and high speeds in dry, high temperature influence in dry, moist and wet environments and in the open
air. These cables can be used for all applications demanding the highest requirements in flexibility, abrasion resistance, ozone and chemical resistance.
For applications extending beyond standard solutions (e. g. composting plants or high-lift conveyor systems working at extremely low speeds), we
recommend that you request our questionnaire, which has been especially designed for energy supply systems. Before installation in cable trays please
read the instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
25888 1G6 10 7,2 58,0 80,0 25895 1 G 95 3/0 20,0 912,0 1050,0
25269 1x6 10 7,2 58,0 80,0 25276 1 x 95 3/0 20,0 912,0 1050,0
25889 1 G 10 8 8,4 96,0 130,0 25896 1 G 120 4/0 21,0 1152,0 1240,0
25270 1 x 10 8 8,4 96,0 130,0 25277 1 x 120 4/0 21,0 1152,0 1240,0
25890 1 G 16 6 9,5 154,0 181,0 25897 1 G 150 250 kcmil 23,8 1440,0 1524,0
25271 1 x 16 6 9,5 154,0 181,0 25278 1 x 150 250 kcmil 23,8 1440,0 1524,0
25891 1 G 25 4 11,0 240,0 274,0 25898 1 G 185 350 kcmil 26,2 1776,0 1932,0
25272 1 x 25 4 11,0 240,0 274,0 25279 1 x 185 350 kcmil 26,2 1776,0 1932,0
25892 1 G 35 2 13,0 336,0 398,0 25899 1 G 240 450 kcmil 29,8 2304,0 2467,0
25273 1 x 35 2 13,0 336,0 398,0 25280 1 x 240 450 kcmil 29,8 2304,0 2467,0
25893 1 G 50 1 15,4 480,0 529,0 25900 1 G 300 550 kcmil 33,1 2880,0 3140,0
25274 1 x 50 1 15,4 480,0 529,0 25281 1 x 300 550 kcmil 33,1 2880,0 3140,0
25894 1 G 70 2/0 17,2 672,0 717,0
25275 1 x 70 2/0 17,2 672,0 717,0
504
Cables according to international Approvals / Single Conductors UL/CSA
Application
These special drag chain core cables permit extended use with extreme requirements, with free movement, without tensile stresses or forced movements.
Suitable for installation in long traverse paths and high speeds in dry, high temperature influence in dry, moist and wet environments and in the open
air. These cables can be used for all applications demanding the highest requirements in flexibility, abrasion resistance, ozone and chemical resistance.
N
The copper screening assures a disturbance-free data and signal transmission for measuring and control systems. For applications extending beyond
standard solutions (e. g. composting plants or high-lift conveyor systems working at extremely low speeds), we recommend that you request our
questionnaire, which has been especially designed for energy supply systems. Before installation in cable trays please read the instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
25901 1G6 10 7,8 71,0 101,0 25908 1 G 95 3/0 23,4 1004,0 1190,0
25282 1x6 10 7,8 71,0 101,0 25289 1 x 95 3/0 23,4 1004,0 1190,0
25902 1 G 10 8 9,7 122,0 168,0 25909 1 G 120 4/0 24,5 1260,0 1400,0
25283 1 x 10 8 9,7 122,0 168,0 25290 1 x 120 4/0 24,5 1260,0 1400,0
25903 1 G 16 6 11,7 180,0 217,0 25910 1 G 150 250 kcmil 27,8 1570,0 1710,0
25284 1 x 16 6 11,7 180,0 217,0 25291 1 x 150 250 kcmil 27,8 1570,0 1710,0
25904 1 G 25 4 13,2 282,0 342,0 25911 1 G 185 350 kcmil 29,4 1911,0 2021,0
25285 1 x 25 4 13,2 282,0 342,0 25292 1 x 185 350 kcmil 29,4 1911,0 2021,0
25905 1 G 35 2 15,2 386,0 468,0 25912 1 G 240 450 kcmil 34,2 2451,0 2601,0
25286 1 x 35 2 15,2 386,0 468,0 25293 1 x 240 450 kcmil 34,2 2451,0 2601,0
25906 1 G 50 1 18,7 535,0 584,0 25913 1 G 300 550 kcmil 37,4 2997,0 3257,0
25287 1 x 50 1 18,7 535,0 584,0 25294 1 x 300 550 kcmil 37,4 2997,0 3257,0
25907 1 G 70 2/0 21,2 750,0 822,0
25288 1 x 70 2/0 21,2 750,0 822,0
505
Cables according to international Approvals / Single Conductors UL/CSA
Application
TOPFLEX 301 (unscreened) These cables are specially designed for use in energy supply chains, automated handling equipment, robots, machine
tools, processing and manufacturing machinery.
TOPFLEX 301-C (screened) Applications as described above, additionally optimal compliance with electromagnetic compatibillity (EMC) requirements
on account of the approx. 85% coverage by the braided screening.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
TOPFLEX 301 double insulated, black unscreened TOPFLEX 301-C black screened EMC
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
75375 1x6 10 7,1 58,0 85,0 75399 1x6 10 7,8 95,0 144,0
75376 1 x 10 8 8,8 96,0 130,0 75400 1 x 10 8 9,5 124,0 170,0
75377 1 x 16 6 10,5 154,0 190,0 75401 1 x 16 6 10,8 186,0 220,0
75378 1 x 25 4 11,2 240,0 280,0 75402 1 x 25 4 12,2 278,0 340,0
75379 1 x 35 2 13,5 336,0 400,0 75403 1 x 35 2 13,7 384,0 460,0
75380 1 x 50 1 15,8 480,0 520,0 75404 1 x 50 1 15,4 530,0 580,0
75381 1 x 70 2/0 18,0 672,0 720,0 75405 1 x 70 2/0 17,6 753,0 820,0
75382 1 x 95 3/0 20,4 912,0 1050,0 75406 1 x 95 3/0 21,7 1006,0 1200,0
75383 1 x 120 4/0 22,2 1152,0 1220,0 75407 1 x 120 4/0 22,4 1257,0 1350,0
75384 1 x 150 300 kcmil 25,0 1440,0 1500,0 75408 1 x 150 300 kcmil 24,3 1562,0 1680,0
75385 1 x 185 350 kcmil 28,0 1776,0 1940,0 75409 1 x 185 350 kcmil 26,5 1895,0 2100,0
75386 1 x 240 500 kcmil 32,5 2304,0 2645,0 75410 1 x 240 500 kcmil 30,3 2704,0 3100,0
506
BRITISH STANDARD CABLES
Cables according to international Approvals / Cables to British Standard
Application
As measurement and control cables in power plants and industrial plants, and in the petrochemical industry. Example BS 5308 P1 T1 CU / PE / CAM
/ PVC = Overall screening, sheath PVC BS 5308 P1 T2 CU / XLPE / IAM / CAM / LSZH / SWA / LSZH = Pair screened, Overall screening, galvanic
round steel wire, halogen free
Dimensions and specifications may be changed without prior notice.
508
Cables according to international Approvals / Cables to British Standard
Application
As measurement and control cables in power plants and industrial plants, and in the petrochemical industry. Example BS 5308 P2 T2 CU / PVC /
CAM / PVC / SWA / PVC = Overall screening, steel wire armouring
Dimensions and specifications may be changed without prior notice.
509
Cables according to international Approvals / Cables to British Standard
Application
As a control and power cable in industrial enviroments. Thanks to the amouring of galvanized steel wire, can be used anywhere that a high level of
mechanical protection is required. Suitable for use outdoors and in the earth.
Example
BS 5467 CU / XLPE / PVC / AWA / PVC = Singlecore
BS 5467 CU / XLPE / PVC / SWA / PVC = Multicore
Dimensions and specifications may be changed without prior notice.
510
Cables according to international Approvals / Cables to British Standard
Application
Unlike power cables acc. to BS 5467, these are LSHF (Low Smoke Halogen Free). Used anywhere where in case of fire damage to human life and
material assets must be prevented, e.g. in industrial plants, airports, underground railways and tunnels.
Example
BS 6724 CU / XLPE / LSZH / AWA / LSZH = Singelcore
BS 6724 CU / XLPE / LSZH / SWA / LSZH = Multicore
Dimensions and specifications may be changed without prior notice.
511
Table of contents
04 | | 512
INFRASTRUCTURE CABLES & WIRES
513
INSTALLATION CABLES
YV patch cable / YR bell sheathed cable in accordance with VDE 0812 516
NHMH-O halogen-free, i.e. free of harmful substances, sheathed cable 300/500V 519
NHMH-J halogen-free, i.e. free of harmful substances, sheathed cable 300/500V 520
515
Installation Cables
Application
YV-Equipment Wires Single core cables for use in small apparatus, switching and intercom system and for data transmission. These cables are not
allowed for the installation of heavy current operation. Equipment wire are used for wiring to the switchbords, amplifiers and dial intercommunicating
systems, measuring instruments, telephone exchange, clock centrals and data processing apparatus etc. These wires are not permitted to apply outside
of equipment for high power ratings.
YR-Bell Sheathed Cables For different applications up to max. 100 V operating voltage, for fixed installation above and beneath plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
YV-Equipment Wires YR-Bell Sheathed Cables
Part no. No.cores x Outer Cop. Weight Part no. No.cores x Outer Cop. Weight
cond. / core approx. mm weight approx. cond. / core approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
28900 1 x 0,3 / 0,7 0,7 0,7 1,2 - 28919 2 x 0,8 / 1,4 4,0 9,6 27,0 -
28901 2 x 0,3 / 0,7 1,4 1,4 2,4 - 28920 3 x 0,8 / 1,4 4,4 14,4 33,0 -
28902 3 x 0,3 / 0,7 1,6 2,1 3,6 - 28921 4 x 0,8 / 1,4 4,9 19,2 41,0 -
28903 1 x 0,4 / 0,8 0,8 1,3 1,8 - 28922 5 x 0,8 / 1,4 5,3 24,0 48,0 -
28904 2 x 0,4 / 0,8 1,6 2,5 3,6 - 28923 6 x 0,8 / 1,4 5,8 28,8 56,0 -
28905 3 x 0,4 / 0,8 1,8 3,8 5,4 - 28924 8 x 0,8 / 1,4 6,5 38,0 70,0 -
28906 1 x 0,5 / 0,9 0,9 2,0 2,5 - 28925 10 x 0,8 / 1,4 7,6 48,0 84,0 -
28907 2 x 0,5 / 0,9 1,8 3,9 5,0 - 28926 12 x 0,8 / 1,4 7,7 58,0 98,0 -
28908 3 x 0,5 / 0,9 2,0 5,9 7,5 - 28927 16 x 0,8 / 1,4 8,6 77,0 124,0 -
28909 4 x 0,5 / 0,9 2,2 7,9 10,0 - 28928 24 x 0,8 / 1,4 10,5 115,0 188,0 -
28910 1 x 0,8 / 1,4 1,4 5,0 6,0 -
28911 2 x 0,8 / 1,4 2,8 10,0 12,0 -
28912 3 x 0,8 / 1,4 3,0 15,0 18,0 -
28913 4 x 0,8 / 1,4 3,4 20,0 24,0 -
28914 1 x 1 / 1,8 1,8 7,9 10,0 -
28915 2 x 1 / 1,8 3,6 16,0 20,0 -
28916 3 x 1 / 1,8 4,0 24,0 30,0 -
28917 1 x 1,4 / 2,2 2,2 15,0 17,0 -
28918 1 x 1,8 / 2,8 2,8 25,0 27,5 -
516
Installation Cables
Application
For industrial- and wiring purposes. Usable in the open, in dry, damp and wet environments in the open and concealed, as well as in masonry and in
beton, not suitable for imbedding in solidified- or compressed-concrete. Outdoor usage is only possible, as long as the cable is protected against direct
sunlight.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. kg / km cross-sec. approx. mm weight approx. kg / km
mm kg / km mm kg / km
39050 1 G 1,5 re 5,4 14,4 40,0 16 39061 4G6 re 15,1 230,0 460,0 10
39001 1 x 1,5 re 5,4 14,4 40,0 16 39012 4x6 re 15,1 230,0 460,0 10
39006 2 x 1,5 re 8,7 29,0 170,0 16 39069 5G6 re 16,1 288,0 540,0 10
39056 3 G 1,5 re 9,1 43,0 135,0 16 39020 5x6 re 16,1 288,0 540,0 10
39007 3 x 1,5 re 9,1 43,0 135,0 16 39053 1 G 10 re 8,4 96,0 155,0 8
39058 4 G 1,5 re 9,8 58,0 160,0 16 39004 1 x 10 re 8,4 96,0 155,0 8
39009 4 x 1,5 re 9,8 58,0 160,0 16 39062 4 G 10 re 17,6 384,0 680,0 8
39066 5 G 1,5 re 10,3 72,0 190,0 16 39013 4 x 10 re 17,6 384,0 680,0 8
39017 5 x 1,5 re 10,3 72,0 190,0 16 39070 5 G 10 re 19,2 480,0 850,0 8
39072
39023
39076
7 G 1,5
7 x 1,5
10 G 1,5 re
re
re
11,5
11,5
13,8
101,0
101,0
144,0
235,0
235,0
330,0
16
16
16
39021
39054
39005
5 x 10
1 G 16
1 x 16
re
rm
rm
19,2
9,9
9,9
480,0
154,0
154,0
850,0
230,0
230,0
8
6
6
O
39077 12 G 1,5 re 14,4 173,0 405,0 16 39063 4 G 16 rm 21,3 614,0 1048,0 6
39055 1 G 2,5 re 6,0 24,0 70,0 14 39014 4 x 16 rm 21,3 614,0 1048,0 6
39024 1 x 2,5 re 6,0 24,0 70,0 14 39071 5 G 16 rm 23,4 768,0 1280,0 6
39057 3 G 2,5 re 10,4 72,0 190,0 14 39022 5 x 16 rm 23,4 768,0 1280,0 6
39008 3 x 2,5 re 10,4 72,0 190,0 14 39079 1 G 25 rm 12,0 240,0 325,0 4
39059 4 G 2,5 re 11,3 96,0 230,0 14 39064 4 G 25 rm 25,8 960,0 1649,0 4
39010 4 x 2,5 re 11,3 96,0 230,0 14 39015 4 x 25 rm 25,8 960,0 1649,0 4
39067 5 G 2,5 re 12,0 120,0 270,0 14 39073 5 G 25 rm 28,7 1200,0 1970,0 4
39018 5 x 2,5 re 12,0 120,0 270,0 14 39065 4 G 35 rm 28,5 1344,0 2000,0 2
39075 7 G 2,5 re 13,2 168,0 342,0 14 39016 4 x 35 rm 28,5 1344,0 2000,0 2
39051 1G4 re 6,6 38,0 80,0 12
39002 1x4 re 6,6 38,0 80,0 12
39074 3G4 re 12,0 115,0 258,0 12
39060 4G4 re 13,0 154,0 330,0 12
39011 4x4 re 13,0 154,0 330,0 12
39068 5G4 re 14,5 192,0 410,0 12
39019 5x4 re 14,5 192,0 410,0 12
39052 1G6 re 7,2 58,0 105,0 10
39003 1x6 re 7,2 58,0 105,0 10
39078 3G6 re 13,0 173,0 320,0 10
517
Installation Cables
Application
These installation cables are made for an effective range of electromagnetic interference alternating fields by a static screen. This screening is specially
used for the installation in computer sector, hospitals or industry measuring observation points with measuring instruments which are sensitive to
interferences. These cables are also ideal for installations in the living rooms of those peoples who are extreme sensitive to radiation. The cable is
suitable for laying on, in and under plaster in dry and damp places as well as in concrete and masonry (a direct laying in shaked or stamped concrete
is excluded). Outdoor laying only is possible if the cable is not exposed to direct sunlight or if the cable is layed in cable conduits. Use in dangerous
areas is not allowed.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Drain- Outer Cop. Weight AWG-No. Part no. No.cores x Drain- Outer Cop. Weight AWG-No.
cross-sec. wire approx. weight approx. cross-sec. wire approx. weight approx.
mm mm mm kg / km kg / km mm mm mm kg / km kg / km
43050 3 G 1,5 re 1,5 10,5 51,0 154,0 16 43063 5 G 10 re 1,5 21,5 485,0 840,0 8
43051 4 G 1,5 re 1,5 11,5 63,0 184,0 16 43064 5 G 16 rm 2,5 26,0 773,0 1353,0 6
43052 5 G 1,5 re 1,5 12,0 80,0 208,0 16 43065 5 G 25 rm 2,5 31,5 1205,0 2017,0 4
43053 7 G 1,5 re 1,5 13,0 106,0 250,0 16
43054 3 G 2,5 re 1,5 12,0 80,0 217,0 14
43055 4 G 2,5 re 1,5 13,0 104,0 256,0 14
43056 5 G 2,5 re 1,5 13,5 128,0 280,0 14
43057 3G4 re 1,5 13,5 123,0 228,0 12
43058 4G4 re 1,5 14,5 159,0 359,0 12
43059 5G4 re 1,5 16,5 200,0 440,0 12
43060 3G6 re 1,5 15,0 187,0 378,0 10
43061 4G6 re 1,5 16,5 235,0 477,0 10
43062 5G6 re 1,5 17,5 293,0 565,0 10
518
Installation Cables
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
x = without green-yellow conductor
O-version: single-core conductor with
black core insulation. Cables between two
and seven cores are without gn-ye core.
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
This plastic-sheathed cable of defined behaviour in case of fire is used for installations in residential dwellings, public buildings as well as in industrial
constructions. Suitable for applications in dry, damp or wet environments for installation above, on, in and beneath plaster, as well as in masonry and
concrete walls, not however for embedding in vibration, compacted or tamped concrete. The cable is also approved for outdoor applications provided
these are not exposed to direct sunlight radiation. Installation of this cable in earth or in water is not permitted.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. kg / km cross-sec. approx. mm weight approx. kg / km
O
mm kg / km mm kg / km
51970 1 x 1,5 re 8,3 14,4 39,0 16 51974 1 x 10 re 11,5 96,0 125,0 8
51976 2 x 1,5 re 8,9 29,0 82,0 16 51980 2 x 10 re 14,9 192,0 340,0 8
51981 3 x 1,5 re 9,2 43,0 92,0 16 51987 4 x 10 re 17,5 384,0 522,0 8
51983 4 x 1,5 re 9,9 58,0 115,0 16 51975 1 x 16 rm 12,9 154,0 188,0 6
51991 7 x 1,5 re 11,5 101,0 167,0 16 51988 4 x 16 rm 19,9 614,0 815,0 6
51971 1 x 2,5 re 9,0 24,0 47,0 14 51989 4 x 25 rm 27,4 960,0 1305,0 4
51977 2 x 2,5 re 10,0 48,0 110,0 14 51990 4 x 35 rm 30,4 1344,0 1750,0 2
51982 3 x 2,5 re 10,6 72,0 128,0 14
51984 4 x 2,5 re 11,0 96,0 152,0 14
51972 1x4 re 9,5 38,0 62,0 12
51978 2x4 re 11,5 77,0 160,0 12
51985 4x4 re 13,4 154,0 244,0 12
51973 1x6 re 10,0 58,0 83,0 10
51979 2x6 re 12,4 115,0 208,0 10
51986 4x6 re 15,9 230,0 345,0 10
519
Installation Cables
Application
This plastic-sheathed cable of defined behaviour in case of fire is used for installations in residential dwellings, public buildings as well as in industrial
constructions. Suitable for applications in dry, damp or wet environments for installation above, on, in and beneath plaster, as well as in masonry and
concrete walls, not however for embedding in vibration, compacted or tamped concrete. The cable is also approved for outdoor applications provided
these are not exposed to direct sunlight radiation. Installation of this cable in earth or in water is not permitted.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. kg / km cross-sec. approx. mm weight approx. kg / km
mm kg / km mm kg / km
51996 3 G 1,5 re 9,4 43,0 92,0 16 52014 5 G 16 rm 23,8 768,0 995,0 6
52001 4 G 1,5 re 10,2 58,0 115,0 16 52007 4 G 25 rm 27,0 960,0 1305,0 4
52009 5 G 1,5 re 10,8 72,0 133,0 16 52015 5 G 25 rm 29,0 1200,0 1580,0 4
52016 7 G 1,5 re 11,4 101,0 168,0 16 52008 4 G 35 rm 29,9 1344,0 1750,0 2
51997 3 G 2,5 re 10,4 72,0 128,0 14
52002 4 G 2,5 re 11,3 96,0 152,0 14
52010 5 G 2,5 re 11,9 120,0 182,0 14
52017 7 G 2,5 re 13,5 158,0 250,0 14
51992 1G4 re 8,6 38,0 62,0 12
51998 3G4 re 11,8 115,0 192,0 12
52003 4G4 re 13,3 154,0 244,0 12
52011 5G4 re 14,8 192,0 300,0 12
51993 1G6 re 9,9 58,0 83,0 10
51999 3G6 re 13,4 173,0 267,0 10
52004 4G6 re 14,8 230,0 345,0 10
52012 5G6 re 16,0 288,0 400,0 10
51994 1 G 10 re 11,2 96,0 125,0 8
52000 3 G 10 re 16,0 288,0 628,0 8
52005 4 G 10 re 17,4 384,0 522,0 8
52013 5 G 10 re 18,9 480,0 620,0 8
51995 1 G 16 rm 11,9 154,0 188,0 6
52006 4 G 16 rm 21,6 614,0 815,0 6
520
Installation Cables
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
LS0H = Low Smoke Zero Halogen
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application O
Halogen-free plastic-sheathed cables with enhanced characteristics in case of fire are used for applications where harm to human life and damage to
property must be prevented in the event of fire, e. g. in industrial installations, communal establishments, hotels, airports, underground stations,
railway stations, hospitals, departmental stores, banks, schools, theatres, multi-storey buildings, process control centres etc. Suitable for installation
in dry, damp or wet environments, for installation above, on, in and beneath plaster as well as in masonry walls and in concrete, not however for direct
embedding in vibration, compacted or tamped concrete. These cables are also suitable for outdoor applications.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
NHXMH-O NHXMH-J
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. kg / km cross-sec. min. - max. weight approx. kg / km
mm mm kg / km mm mm kg / km
53300 1 x 1,5 re 5,0 - 8,4 15,0 49,0 16 53192 1G4 re 6,0 - 9,5 39,0 80,0 12
53306 2 x 1,5 re 7,6 - 9,2 29,0 110,0 16 53352 3G4 re 10,1 - 12,2 115,0 235,0 12
53301 1 x 2,5 re 5,4 - 8,8 24,0 60,0 14 53360 4G4 re 11,3 - 13,7 154,0 300,0 12
53307 2 x 2,5 re 8,4 - 10,1 48,0 136,0 14 53368 5G4 re 12,5 - 15,1 192,0 345,0 12
53302 1x4 re 6,0 - 9,5 39,0 80,0 12 53193 1G6 re 6,4 - 10,0 58,0 111,0 10
53308 2x4 re 9,6 - 11,6 77,0 202,0 12 53353 3G6 re 11,5 - 13,9 173,0 323,0 10
53303 1x6 re 6,4 - 10,0 58,0 111,0 10 53361 4G6 re 12,7 - 15,3 230,0 400,0 10
53304 1 x 10 re 7,4 - 11,3 96,0 160,0 8 53369 5G6 re 13,7 - 16,6 288,0 475,0 10
53305 1 x 16 rm 8,5 - 12,4 154,0 232,0 6 53194 1 G 10 re 7,4 - 11,3 96,0 160,0 8
53354 3 G 10 re 13,8 - 16,7 288,0 485,0 8
NHXMH-J 53362 4 G 10 re 15,1 - 18,2 384,0 603,0 8
Part no. No.cores x Outer Cop. Weight AWG-No. 53370 5 G 10 re 16,3 - 19,7 480,0 720,0 8
cross-sec. min. - max. weight approx. kg / km 53195 1 G 16 rm 8,5 - 12,4 154,0 232,0 6
mm mm kg / km 53355 3 G 16 rm 16,5 - 20,0 461,0 850,0 6
53350 3 G 1,5 re 8,0 - 9,6 43,0 130,0 16 53363 4 G 16 rm 18,0 - 21,8 615,0 940,0 6
53358 4 G 1,5 re 8,5 - 10,3 58,0 151,0 16 53371 5 G 16 rm 19,7 - 23,8 768,0 1142,0 6
53366 5 G 1,5 re 9,1 - 11,0 72,0 177,0 16 53356 3 G 25 rm 20,4 - 24,6 720,0 1152,0 4
53374 7 G 1,5 re 9,9 - 11,9 101,0 209,0 16 53364 4 G 25 rm 22,6 - 27,3 960,0 1432,0 4
53351 3 G 2,5 re 8,7 - 10,6 72,0 163,0 14 53372 5 G 25 rm 24,7 - 29,8 1200,0 1800,0 4
53359 4 G 2,5 re 9,5 - 11,5 96,0 200,0 14 53357 3 G 35 rm 22,7 - 27,4 1008,0 1503,0 2
53367 5 G 2,5 re 10,4 - 12,3 120,0 238,0 14 53365 4 G 35 rm 24,9 - 30,0 1344,0 1930,0 2
53375 7 G 2,5 re 11,4 - 13,8 168,0 300,0 14 53373 5 G 35 rm 27,5 - 33,2 1680,0 2490,0 2
521
TELEPHONE & FIRE WARNING CABLES
J-2Y(St)Y St III Bd 16 Mbits/s (Cat. 3) ISDN/EDV (Z=100 ohm), meter marking 529
523
Telephone and Fire Warning Cables
10x cable Local cables with more than 100 pairs the
2)
Application
These external subscriber telephone cables are installed as telecommunication connection cable for connecting the telephone extension to the telephone
exchange or central offices and as well as for industrial plants. These subscriber connecting cables are suitable for laying in under ground, in cable
ducts and cable conduits - and also for indoor-laying. Both sides of PE-copolymere coated aluminium type (L), which is spliced with the outer PE-sheath
ensures a barrier against water vapour and diagonally water-proof. Black coloured PE-sheath is UV-resistant. The Polyethelene material
(PE 2Y) is halogen-free.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
34100 2 x 2 x 0,6 8,0 11,0 82,0 - 34130 2 x 2 x 0,8 11,0 20,0 102,0 -
34101 4 x 2 x 0,6 10,0 23,0 127,0 - 34131 4 x 2 x 0,8 12,0 40,0 158,0 -
34102 6 x 2 x 0,6 11,5 34,0 132,0 - 34132 6 x 2 x 0,8 13,0 60,0 179,0 -
34103 10 x 2 x 0,6 12,5 57,0 171,0 - 34133 10 x 2 x 0,8 14,5 101,0 241,0 -
34104 20 x 2 x 0,6 15,5 113,0 268,0 - 34134 20 x 2 x 0,8 18,0 201,0 393,0 -
34105 30 x 2 x 0,6 17,5 170,0 358,0 - 34135 30 x 2 x 0,8 21,0 302,0 540,0 -
34106 40 x 2 x 0,6 19,5 226,0 438,0 - 34136 40 x 2 x 0,8 23,0 402,0 675,0 -
34107 50 x 2 x 0,6 21,0 283,0 531,0 - 34137 50 x 2 x 0,8 25,5 503,0 842,0 -
34108 70 x 2 x 0,6 24,5 396,0 712,0 - 34138 70 x 2 x 0,8 29,0 704,0 1105,0 -
34109 100 x 2 x 0,6 28,0 565,0 950,0 - 34139 100 x 2 x 0,8 34,0 1005,0 1524,0 -
34110 150 x 2 x 0,6 33,0 848,0 1348,0 - 34140 150 x 2 x 0,8 40,0 1508,0 2208,0 -
34111 200 x 2 x 0,6 37,0 1131,0 1758,0 - 34141 200 x 2 x 0,8 46,5 2011,0 2915,0 -
34112 250 x 2 x 0,6 40,5 1414,0 2137,0 - 34142 250 x 2 x 0,8 51,0 2514,0 3575,0 -
34113 300 x 2 x 0,6 44,0 1696,0 2533,0 - 34143 300 x 2 x 0,8 53,0 3016,0 4232,0 -
34114 350 x 2 x 0,6 47,5 1979,0 2954,0 - 34144 350 x 2 x 0,8 56,5 3519,0 4940,0 -
34115 400 x 2 x 0,6 50,0 2262,0 3342,0 - 34145 400 x 2 x 0,8 60,0 4022,0 5565,0 -
34146 500 x 2 x 0,8 68,0 5027,0 6955,0 -
34147 600 x 2 x 0,8 73,0 6032,0 8240,0 -
524
Telephone and Fire Warning Cables
10x cable Local cables with more than 100 pairs the
2)
Application
These external subscriber telephone cables are installed as telecommunication connection cable for connecting the telephone extension to the telephone
exchange for transmitting signals. These subscriber connecting cables are suitable for laying in under ground, in cable ducts and cable conduits.
According to DIN VDE 0800 part 1, these cables are allowed in all types of installation plants. The cavities of the cable core, filled continuously with
viscous compound (F). Both sides of PE-copolymere coated aluminium type (L), which is spliced with the outer PE-sheath, ensures a barrier against
water vapour and crosswise and longitudinal water tightness. Black coloured PE-sheath is UV-resistant. The Polyethelene material (PE 2Y) P
is halogen-free.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
34007 2 x 2 x 0,6 7,5 11,0 80,0 - 34029 2 x 2 x 0,8 8,5 20,0 100,0 -
34008 4 x 2 x 0,6 9,0 23,0 140,0 - 34030 4 x 2 x 0,8 10,0 40,0 180,0 -
34009 6 x 2 x 0,6 12,0 34,0 150,0 - 34019 6 x 2 x 0,8 8,5 60,0 190,0 -
34010 10 x 2 x 0,6 13,5 57,0 190,0 - 34020 10 x 2 x 0,8 15,0 101,0 280,0 -
34011 20 x 2 x 0,6 16,0 113,0 310,0 - 34021 20 x 2 x 0,8 19,0 201,0 480,0 -
34012 30 x 2 x 0,6 19,0 170,0 430,0 - 34022 30 x 2 x 0,8 23,0 302,0 670,0 -
34013 40 x 2 x 0,6 20,5 226,0 545,0 - 34023 40 x 2 x 0,8 26,0 402,0 860,0 -
34014 50 x 2 x 0,6 23,0 283,0 660,0 - 34024 50 x 2 x 0,8 29,0 503,0 1060,0 -
34015 70 x 2 x 0,6 26,0 396,0 895,0 - 34025 70 x 2 x 0,8 33,0 704,0 1420,0 -
34016 100 x 2 x 0,6 31,5 565,0 1230,0 - 34026 100 x 2 x 0,8 39,0 1005,0 1980,0 -
34017 150 x 2 x 0,6 37,5 848,0 1780,0 - 34027 150 x 2 x 0,8 47,0 1508,0 2940,0 -
34018 200 x 2 x 0,6 42,5 1131,0 2320,0 - 34028 200 x 2 x 0,8 51,0 2011,0 3780,0 -
34036 250 x 2 x 0,6 47,5 1414,0 2910,0 - 34031 250 x 2 x 0,8 58,0 2514,0 4660,0 -
34037 300 x 2 x 0,6 51,5 1696,0 3490,0 - 34032 300 x 2 x 0,8 62,5 3016,0 5570,0 -
34038 350 x 2 x 0,6 55,0 1979,0 3970,0 - 34033 350 x 2 x 0,8 68,0 3519,0 6750,0 -
34039 400 x 2 x 0,6 60,5 2262,0 4480,0 - 34034 400 x 2 x 0,8 73,0 4022,0 7630,0 -
34040 500 x 2 x 0,6 66,0 2827,0 5460,0 - 34035 500 x 2 x 0,8 81,5 5027,0 9540,0 -
525
Telephone and Fire Warning Cables
Application
J-YY installation cables are preferably used as telephone cables in telephone stations and sub-extensions,in dry and damp premises, and in or under
plaster, in the open air for fixed installation. Telephone-Installation cables are not allowed for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
33100 2 x 2 x 0,6 4,5 11,0 34,0 - 33107 30 x 2 x 0,6 13,0 170,0 284,0 -
33101 4 x 2 x 0,6 6,5 23,0 59,0 - 33108 40 x 2 x 0,6 15,0 226,0 364,0 -
33102 6 x 2 x 0,6 7,0 34,0 74,0 - 33109 50 x 2 x 0,6 16,5 283,0 451,0 -
33103 10 x 2 x 0,6 8,5 57,0 111,0 - 33110 60 x 2 x 0,6 17,5 339,0 529,0 -
33104 16 x 2 x 0,6 10,0 90,0 160,0 - 33111 80 x 2 x 0,6 20,3 452,0 700,0 -
33105 20 x 2 x 0,6 11,0 113,0 200,0 - 33112 100 x 2 x 0,6 22,3 565,0 850,0 -
33106 24 x 2 x 0,6 11,5 136,0 224,0 -
526
Telephone and Fire Warning Cables
Application
This cable type with electrostatic screening (St) protects the transmission circuits against extern electrical interferences. Installation cables laid up in
P
pairs are preferably used for telecommunications installations, in dry and damp premises, and in or under plaster, in the open air for fixed installation.
These cables are suitable for telephone stations and sub-extensions, for signal and data transmission. Telephone-Installation cables are not allowed
for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
33001 2 x 2 x 0,6 5,0 13,0 40,0 - 33018 2 x 2 x 0,8 7,0 21,0 60,0 -
33002 3 x 2 x 0,6 6,3 18,0 50,0 - 33019 3 x 2 x 0,8 8,5 31,0 80,0 -
33003 4 x 2 x 0,6 6,5 24,0 60,0 - 33020 4 x 2 x 0,8 9,0 41,0 100,0 -
33004 5 x 2 x 0,6 7,2 30,0 70,0 - 33021 5 x 2 x 0,8 9,5 52,0 120,0 -
33005 6 x 2 x 0,6 7,5 35,0 80,0 - 33022 6 x 2 x 0,8 11,0 62,0 140,0 -
33006 8 x 2 x 0,6 8,0 46,0 90,0 - 33023 8 x 2 x 0,8 11,5 82,0 170,0 -
33007 10 x 2 x 0,6 10,0 58,0 110,0 - 33024 10 x 2 x 0,8 13,2 102,0 220,0 -
33008 12 x 2 x 0,6 10,2 71,0 130,0 - 33025 12 x 2 x 0,8 14,2 123,0 250,0 -
33009 16 x 2 x 0,6 11,0 93,0 160,0 - 33026 16 x 2 x 0,8 16,0 164,0 320,0 -
33010 20 x 2 x 0,6 12,0 116,0 190,0 - 33027 20 x 2 x 0,8 17,0 204,0 380,0 -
33011 24 x 2 x 0,6 13,0 139,0 220,0 - 33028 24 x 2 x 0,8 19,0 244,0 460,0 -
33012 30 x 2 x 0,6 14,0 172,0 280,0 - 33029 30 x 2 x 0,8 20,8 304,0 560,0 -
33013 40 x 2 x 0,6 15,0 220,0 350,0 - 33030 40 x 2 x 0,8 23,0 405,0 710,0 -
33014 50 x 2 x 0,6 17,0 286,0 430,0 - 33031 50 x 2 x 0,8 26,0 505,0 900,0 -
33015 60 x 2 x 0,6 19,0 342,0 500,0 - 33032 60 x 2 x 0,8 28,0 606,0 1050,0 -
33016 80 x 2 x 0,6 21,0 455,0 640,0 - 33033 80 x 2 x 0,8 31,5 807,0 1400,0 -
33017 100 x 2 x 0,6 24,0 568,0 850,0 - 33034 100 x 2 x 0,8 33,0 1008,0 1750,0 -
527
Telephone and Fire Warning Cables
Application
This cable type with electrostatic screening (St) protects the transmission circuits against extern electrical interferences. Installation cables laid up in
pairs are preferably used for telecommunication installation in dry and damp premises, and in or under plaster, in the open air for fixed installation.
These cables are suitable for telephone stations and sub-extensions, for signal and data transmission. Telephone-Installation cables are not allowed
for purposes of high current and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
33035 1 x 2 x 0,8 4,5 11,0 38,0 - 33045 16 x 2 x 0,8 16,0 164,0 320,0 -
33036 2 x 2 x 0,8 7,0 21,0 60,0 - 33046 20 x 2 x 0,8 17,0 204,0 380,0 -
33037 3 x 2 x 0,8 8,5 31,0 80,0 - 33047 24 x 2 x 0,8 19,0 244,0 460,0 -
33038 4 x 2 x 0,8 9,0 41,0 100,0 - 33048 30 x 2 x 0,8 20,8 304,0 560,0 -
33039 5 x 2 x 0,8 9,5 52,0 120,0 - 33049 40 x 2 x 0,8 23,0 405,0 710,0 -
33040 6 x 2 x 0,8 11,0 62,0 140,0 - 33050 50 x 2 x 0,8 26,0 505,0 900,0 -
33041 8 x 2 x 0,8 11,5 82,0 170,0 - 33051 60 x 2 x 0,8 28,0 606,0 1050,0 -
33042 10 x 2 x 0,8 13,2 102,0 220,0 - 33052 80 x 2 x 0,8 31,5 807,0 1400,0 -
33043 12 x 2 x 0,8 14,2 123,0 250,0 - 33053 100 x 2 x 0,8 33,0 1008,0 1750,0 -
33044 14 x 2 x 0,8 14,6 145,0 280,0 -
528
Telephone and Fire Warning Cables
Application
Used as data transmission and connection cable suitable for fixed installation in and under plaster, for data transmission applications, for periphery
instrument data processing computers. Suitable for transmission of analog- and digital signals up to 16 Mbit/s. High cross-talk attentuation values.
P
Suitable as connecting cable for periphery equipment, data processing systems, monitors, printers and cash register systems. The static screen (St)
screen assures a disturbance-free data and signal transmission for measuring and control systems. These cables are not allowed for purposes of high
curren and power installation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
33200 2 x 2 x 0,6 6,1 13,0 44,0 - 33206 30 x 2 x 0,6 14,0 172,0 302,0 -
33201 4 x 2 x 0,6 7,5 24,0 80,0 - 33207 40 x 2 x 0,6 15,5 229,0 376,0 -
33202 6 x 2 x 0,6 7,6 35,0 86,0 - 33208 50 x 2 x 0,6 17,3 266,0 480,0 -
33203 8 x 2 x 0,6 8,8 46,0 105,0 - 33209 60 x 2 x 0,6 18,1 342,0 560,0 -
33204 10 x 2 x 0,6 8,8 58,0 112,0 - 33210 80 x 2 x 0,6 22,0 455,0 748,0 -
33205 20 x 2 x 0,6 12,9 116,0 218,0 - 33211 100 x 2 x 0,6 25,2 588,0 940,0 -
529
Telephone and Fire Warning Cables
Application
In DIN VDE 0800 the operational areas are defined, where the application of switchboard cables permit. These are preferred for the transmission of
data signals of telecommunication and control processings i. e. in interlocking installations, to connect the outdoor cables with relay groups as well
as for fixed installation to interconnect the racks and distributor frames. This type is not allowed for the installation of heavy current operation.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
530
Telephone and Fire Warning Cables
Application
The halogen-free installation cables with improved characteristics in the case of fire are used for the telephone transmission, measurement and control
technology. The static screen protects the transmission circuits against outer electrical interferences. A fire propagation is prevented through high
oxygen index of the insulation material and produce no corrosive gases in case of fire. Those cables are preferably used for telecommunication
P
installations in dry and damp premises, and in or under plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
34050 2 x 2 x 0,6 5,4 14,0 50,0 - 34061 2 x 2 x 0,8 6,5 25,0 70,0 -
34051 4 x 2 x 0,6 7,3 25,0 91,0 - 34062 4 x 2 x 0,8 9,0 45,0 135,0 -
34052 6 x 2 x 0,6 7,7 37,0 100,0 - 34063 6 x 2 x 0,8 10,0 65,0 151,0 -
34053 10 x 2 x 0,6 9,1 59,0 147,0 - 34064 10 x 2 x 0,8 11,5 106,0 230,0 -
34054 20 x 2 x 0,6 13,5 116,0 308,0 - 34065 20 x 2 x 0,8 20,4 206,0 507,0 -
34055 30 x 2 x 0,6 15,1 172,0 350,0 - 34066 30 x 2 x 0,8 21,5 307,0 600,0 -
34056 40 x 2 x 0,6 16,5 229,0 465,0 - 34067 40 x 2 x 0,8 23,0 407,0 788,0 -
34057 50 x 2 x 0,6 18,6 286,0 571,0 - 34068 50 x 2 x 0,8 25,0 508,0 972,0 -
34058 60 x 2 x 0,6 19,3 342,0 662,0 - 34069 60 x 2 x 0,8 28,0 608,0 1120,0 -
34059 80 x 2 x 0,6 24,6 455,0 877,0 - 34070 80 x 2 x 0,8 31,5 809,0 1475,0 -
34060 100 x 2 x 0,6 27,2 568,0 1055,0 - 34071 100 x 2 x 0,8 32,3 1010,0 1804,0 -
531
Telephone and Fire Warning Cables
Application
The halogen-free installation cables with improved characteristics in the case of fire are used for the telephone transmission, measurement and control
technology. The static screen protects the transmission circuits against outer electrical interferences. A fire propagation is prevented through high
oxygen index of the insulation material and produce no corrosive gases in case of fire. Those cables are preferably used for telecommunication
installations in dry and damp premises, and in or under plaster.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
34116 2 x 2 x 0,8 6,8 25,0 70,0 - 34122 40 x 2 x 0,8 24,5 407,0 788,0 -
34117 4 x 2 x 0,8 10,5 45,0 135,0 - 34123 50 x 2 x 0,8 27,1 508,0 972,0 -
34118 6 x 2 x 0,8 10,9 65,0 151,0 - 34124 60 x 2 x 0,8 29,4 608,0 1120,0 -
34119 10 x 2 x 0,8 13,1 106,0 230,0 - 34125 80 x 2 x 0,8 33,2 809,0 1475,0 -
34120 20 x 2 x 0,8 20,4 206,0 507,0 - 34126 100 x 2 x 0,8 37,2 1010,0 1804,0 -
34121 30 x 2 x 0,8 21,5 307,0 600,0 -
532
Telephone and Fire Warning Cables
Application
Used as data transmission and connection cable suitable for fixed installation in and under plaster, for data transmission applications, for periphery
instrument data processing computers. Suitable for transmission of analog- and digital signals up to 16 Mbit/s. High cross-talk attenuation values.
P
Suitable as connecting cable for periphery equipment, data processing systems, monitors, Printers and cash register systems. The static screen (St)
screen assures a disturbance-free data and signal transmission for measuring and control systems.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
34166 2 x 2 x 0,6 5,8 13,0 44,0 - 34172 30 x 2 x 0,6 15,0 172,0 302,0 -
34167 4 x 2 x 0,6 9,2 24,0 80,0 - 34173 40 x 2 x 0,6 16,8 229,0 376,0 -
34168 6 x 2 x 0,6 9,3 35,0 86,0 - 34174 50 x 2 x 0,6 18,5 266,0 480,0 -
34169 8 x 2 x 0,6 9,5 46,0 105,0 - 34175 60 x 2 x 0,6 20,2 342,0 560,0 -
34170 10 x 2 x 0,6 9,8 58,0 112,0 - 34176 80 x 2 x 0,6 23,0 455,0 748,0 -
34171 20 x 2 x 0,6 12,7 116,0 218,0 - 34177 100 x 2 x 0,6 25,2 588,0 940,0 -
533
POWER, SECURITY & MEDIUM VOLTAGE CABLES
NYCY Underground cable 0.6/1 kV, with concentric conductor VDE approved 540
NYCWY Underground cable 0.6/1 kV, with concentric conductor VDE approved 542
NAYCWY Underground cable 0.6/1 kV, with concentric conductor VDE approved 547
N2XY Underground cable 0.6/1 kV, VDE approved, increased current load 548
N2XCY Underground cable 0.6/1 kV, with concentric conductor, VDE approved, increased current load 549
NA2XY Underground cable 0.6/1 kV, VDE approved, increased current load 551
A-LiY(StE)Y Data transmission cable for gas stations and refineries with BAM certificate 552
N2XCH Power cable 0.6/1 kV, halogen-free, with concentric conductor, without functionality 559
N2XH-FE 180/E 30 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 563
N2XCH-FE 180/E 30 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 565
(N)HXH-FE 180/E 30 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 567
(N)HXCH-FE 180/E 30 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 569
N2XH-FE 180/E 90 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 571
N2XCH-FE 180/E 90 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 573
(N)HXH-FE 180/E 90 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 575
(N)HXCH-FE 180/E 90 Security cable, halogen-free, 0.6/1 kV, with improved fire behavior 577
N2XSY 6/10kV, 12/20kV, 18/30kV VPE-insulated Cu-conductor, single core, screened, PVC jacket 585
N2XS2Y 6/10kV, 12/20kV, 18/30kV VPE-insulated Cu-conductor, single core, screened, PE jacket 587
N2XS(F)2Y 6/10kV, 12/20kV, 18/30kV VPE-insulated Cu-conductor, single core, screened, longitudinally water-tight, PE jacket 589
VPE-insulated Cu-conductor, single core, screened, longitudinally and
N2XS(FL)2Y 6/10kV transversely water-tight PE jacket
591
NA2XSY 6/10kV, 12/20kV, 18/30kV VPE-insulated alu-conductor, single core, screened, PVC jacket 593
NA2XS2Y 6/10kV, 12/20kV, 18/30kV VPE-insulated Al-conductor, single core, screened, PE jacket 595
NA2XS(F)2Y 6/10kV, 12/20kV, 18/30kV VPE-insulated Al-conductor, single core, screened, longitudinally water-tight, PE jacket 597
VPE-insulated Al-conductor, single core, screened, longitudinally and
NA2XS(FL)2Y 6/10kV, 12/20kV, 18/30kV transversely water-tight PE jacket
599
N2XSEH 3x 6/10kV Power cable 0.6/1 kV, with PE outer sheath 603
535
CODE-DESIGNATION FOR POWER CABLES
WITH PVC OR XLPE INSULATION
Design Identification Explanations
of design
A Aluminium conductors
Y Insulation of thermoplastic
Polyvinylchloride (PVC)
2Y PE sheath
536
UNDERGROUND CABLES & POWER DISTRIBUTION CABLES
Energy- and Power Cable / Power Cables / Power cables for energy supply
Application
Power cables for energy supply are installed in open air, in underground, in water, in concrete, indoors, in cable ducts, power stations, for industry
and distribution boards as well as in subscriber networks, where mechanical damages are not to be expected.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
538
Energy- and Power Cable / Power Cables / Power cables for energy supply
3+1/2-conductors
No.cores x Outer Cop. Weight J type AWG-No. O type AWG-No.
cross-sec. app. mm weight app. kg / km Part no. Part no.
mm kg / km
3 x 25 / 16 rm/re 24,5 874,0 1530,0 32035 4 - 32123 4 -
3 x 35 / 16 sm/re 26,0 1162,0 1750,0 32036 2 - 32124 2 -
3 x 50 / 25 sm 29,0 1680,0 2350,0 32037 1 - 32125 1 -
3 x 70 / 35 sm/rm 32,0 2352,0 2850,0 32038 2/0 - 32126 2/0 -
3 x 95 / 50 sm 38,0 3216,0 3850,0 32039 3/0 - 32127 3/0 -
3 x 120 / 70 sm 41,0 4128,0 4780,0 32040 4/0 - 32128 4/0 -
3 x 150 / 70 sm 46,0 4992,0 5800,0 32041 300 kcmil - 32129 300 kcmil -
3 x 185 / 95 sm 51,0 6240,0 7600,0 32042 350 kcmil - 32130 350 kcmil -
3 x 240 / 120 sm 58,0 8064,0 9800,0 32043 500 kcmil - 32131 500 kcmil -
3 x 300 / 150 sm 64,0 10080,0 11500,0 32256 600 kcmil -
539
Energy- and Power Cable / Power Cables / Power cables for energy supply
NYCY power cable, 0,6/1kV, VDE approved, with concentric copper conductor
Application
Power cables for energy supply are used for industry and distribution boards, power stations, house connecting boxes and street lighting as well as
control cable for the transmission of control impulses and test datas. Overall, where increased electrical and also mechanical protection are required.
Those cables are installed in open air, in underground, in water, in concrete, indoors and in cable ducts. The concentric conductor (C) is allowed to
use as PE-, PEN-conductor or as screen.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
540
Energy- and Power Cable / Power Cables / Power cables for energy supply
NYCY power cable, 0,6/1kV, VDE approved, with concentric copper conductor
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km
mm kg / km
32224 5 x 10 re / 10 23,0 600,0 1000,0 8
32226 7 x 1,5 re / 1,5 16,0 124,0 320,0 16
32227 7 x 1,5 re / 2,5 16,0 133,0 350,0 16
32241 7 x 2,5 re / 2,5 17,5 200,0 450,0 14
32225 7x4 re / 4 21,0 315,0 670,0 12
32255 7x6 re / 6 24,0 470,0 790,0 10
32228 8 x 1,5 re / 1,5 17,0 138,0 380,0 16
32229 8 x 1,5 re / 2,5 17,0 147,0 400,0 16
32242 8 x 2,5 re / 2,5 18,0 224,0 510,0 14
32230 10 x 1,5 re / 2,5 19,0 176,0 440,0 16
32243 10 x 2,5 re / 4 20,5 286,0 600,0 14
32231 12 x 1,5 re / 2,5 20,0 205,0 500,0 16
32244 12 x 2,5 re / 4 21,0 334,0 660,0 14
32232 14 x 1,5 re / 2,5 20,5 234,0 540,0 16
32245 14 x 2,5 re / 4 22,0 382,0 760,0 14
32246 14 x 2,5 re / 6 22,5 403,0 800,0 14
32233 16 x 1,5 re / 4 22,0 276,0 600,0 16
32247 16 x 2,5 re / 6 23,0 451,0 910,0 14
32234 19 x 1,5 re / 4 23,0 320,0 690,0 16
32248 19 x 2,5 re / 6 23,5 523,0 950,0 14
32235 21 x 1,5 re / 6 24,0 369,0 810,0 16
32249 21 x 2,5 re / 10 26,0 571,0 1100,0 14
32236 24 x 1,5 re / 6 26,0 413,0 860,0 16
32250 24 x 2,5 re / 10 28,0 696,0 1300,0 14
32237 30 x 1,5 re / 6 27,0 499,0 1230,0 16
32251 30 x 2,5 re / 10 30,0 840,0 1610,0 14
32238 40 x 1,5 re / 10 30,0 696,0 1590,0 16
32252 40 x 2,5 re / 10 35,0 1080,0 2100,0 14
32239 52 x 1,5 re / 10 32,0 869,0 1820,0 16
32253 52 x 2,5 re / 10 38,0 1368,0 2500,0 14
32240 61 x 1,5 re / 10 33,0 998,0 2000,0 16
32254 61 x 2,5 re / 10 40,0 1584,0 2850,0 14
541
Energy- and Power Cable / Power Cables / Power cables for energy supply
NYCWY power cable, 0,6/1kV, with concentric copper conductor, VDE approved
Application
Power cables for energy supply are used for industry and distribution boards, power stations, house connecting boxes and street lighting as well as
control cable for the transmission of control impulses and test datas. Overall, where increased electrical and also mechanical protection are required.
Those cables are installed in open air, in underground, in water, in concrete, indoors and in cable ducts. The concentric conductor (C) is allowed to
use as PE-, PEN-conductor or as screen. The corrugated design (Ceander) of the concentric conductor permits any number of cable junctions during
assembly, without any conductors having to be cut. This ensures a optimal reliability.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
542
Energy- and Power Cable / Power Cables / Power cables for energy supply
NYCWY power cable, 0,6/1kV, with concentric copper conductor, VDE approved
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km
mm kg / km
32284 4 x 25 rm / 16 28,0 1142,0 1800,0 4
32285 4 x 35 sm / 16 29,0 1526,0 2050,0 2
32286 4 x 50 sm / 25 33,0 2203,0 2700,0 1
32287 4 x 70 sm / 35 37,0 3082,0 3750,0 2/0
32288 4 x 95 sm / 50 43,5 4208,0 5000,0 3/0
32289 4 x 120 sm / 70 47,0 5388,0 6350,0 4/0
32290 4 x 150 sm / 70 51,0 6540,0 7650,0 300 kcmil
32291 4 x 185 sm / 95 56,0 8159,0 9350,0 350 kcmil
32292 4 x 240 sm / 120 62,5 10546,0 11600,0 500 kcmil
3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP
543
Energy- and Power Cable / Power Cables / Power cables for energy supply
Application
Power cables for energy supply are installed in open air, in underground, in water, in concrete, indoors, in cable ducts, power stations, for industry
and distribution boards as well as in subscriber networks, where mechanical damages are not be expected.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
544
Energy- and Power Cable / Power Cables / Power cables for energy supply
3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP
545
Energy- and Power Cable / Power Cables / Power cables for energy supply
Application
Power cables for energy supply are installed in open air, in underground, in water, in concrete, indoors, in cable ducts, power stations, for industry
and distribution boards as well as in subscriber networks. Usable in extreme working conditions due to the robust PE outer sheath.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
546
Energy- and Power Cable / Power Cables / Power cables for energy supply
NAYCWY power cable, 0,6/1kV, with concentric copper conductor, VDE approved
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
sm = sectional conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
Power distribution cables, preferably used for underground installation, primarily in local networks, for industrial applications and switching systems,
power stations. Wherever increased electrical and mechanical protection are required. Installation in water, outdoors, in concrete, indoors and in cable
ducts. The concentric conductor (C) can be used as a PE or PEN conductor or as a screen. The corrugated design (Ceander) of the conc entric conductor
permits any number of cable junctions during assembly, without any conductors having to be cut. This ensures a optimal reliability.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
547
Energy- and Power Cable / Power Cables / Power cables for energy supply
N2XY power cable, 0,6/1kV, VDE approved, higher current carrying capacity
Application
Power distribution cables for use in underground, in water, outdoors, in concrete, indoors, in cable ducts, for power stations, industrial applications
and switching systems, as well as in local networks if no mechanical damage is expected. Respecting the permissible operating temperature at the
conductor of +90C permits a higher current carrying capacity than PVC insulated power distribution cables.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
548
Energy- and Power Cable / Power Cables / Power cables for energy supply
N2XCY power cable, 0,6/1kV, VDE approved, higher current carrying capacity
Application
Power distribution cables for industrial applications and switching systems, power stations, residental connections and street lighting, as well as control
cables for transmitting control pulses and measurements. Wherever increased electrical and mechanical protection are required. For installation in
underground, in water, outdoors, in concrete and cable ducts. Respecting the permissible operating temperature at the conductor of +90C permits
a higher current carrying capacity than PVC insulated power distribution cables. The concentric conductor (C) can be used as a PE or PEN-conductor
or as a screen.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
549
Energy- and Power Cable / Power Cables / Power cables for energy supply
N2XCY power cable, 0,6/1kV, VDE approved, higher current carrying capacity
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km
mm kg / km
33240 4 x 1,5 re / 1,5 14,5 81,0 260,0 16
33241 4 x 2,5 re / 2,5 15,5 128,0 350,0 14
33242 4x4 re / 4 17,0 200,0 470,0 12
33243 4x6 re / 6 18,5 297,0 590,0 10
33244 4 x 10 re / 10 21,0 504,0 900,0 8
33245 4 x 16 re / 16 23,0 796,0 1250,0 6
33246 4 x 25 re / 16 27,2 1142,0 1559,0 4
33247 4 x 35 sm / 16 27,2 1526,0 1812,0 2
33248 4 x 50 sm / 25 30,6 2203,0 2413,0 1
33249 4 x 70 sm / 35 35,9 3082,0 3420,0 2/0
33250 4 x 95 sm / 50 39,5 4208,0 4561,0 3/0
33251 4 x 120 sm / 16 44,5 5388,0 5819,0 4/0
33252 4 x 150 sm / 70 48,6 6540,0 6972,0 300 kcmil
33253 5 x 1,5 re / 1,5 15,0 95,0 330,0 16
33254 5 x 2,5 re / 2,5 16,0 152,0 400,0 14
33255 5x4 re / 4 19,0 238,0 560,0 12
33256 5x6 re / 6 21,0 355,0 710,0 10
33257 5 x 10 re / 10 23,0 600,0 1000,0 8
33258 5 x 16 re / 16 24,3 931,0 1233,0 6
33259 7 x 1,5 re / 1,5 16,0 133,0 350,0 16
33260 7 x 2,5 re / 2,5 17,5 200,0 450,0 14
33261 7x4 re / 4 21,0 315,0 670,0 12
33262 7x6 re / 6 24,0 470,0 790,0 10
33263 10 x 1,5 re / 2,5 19,0 176,0 440,0 16
33264 10 x 2,5 re / 4 20,5 286,0 600,0 14
33265 12 x 1,5 re / 2,5 20,0 205,0 500,0 16
33266 12 x 2,5 re / 4 21,0 334,0 660,0 14
33267 14 x 1,5 re / 2,5 20,5 234,0 540,0 16
33268 14 x 2,5 re / 6 22,5 403,0 800,0 14
33269 19 x 1,5 re / 2,5 23,0 320,0 690,0 16
33270 19 x 2,5 re / 6 23,5 523,0 950,0 14
33271 30 x 1,5 re / 2,5 27,0 499,0 1230,0 16
33272 30 x 2,5 re / 10 30,0 840,0 1610,0 14
33273 40 x 1,5 re / 2,5 30,0 696,0 1590,0 16
33274 40 x 2,5 re / 10 35,0 1080,0 2100,0 14
3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP
550
Energy- and Power Cable / Power Cables / Power cables for energy supply
NA2XY power cable, 0,6/1kV, VDE approved, higher current carrying capacity
Application
Power distribution cables for use in underground, in water, outdoors, in concrete, indoors, in cable ducts, for power stations, industrial applications
and switching systems, as well as in local networks if no mechanical damage is expected. Respecting the permissible operating temperature at the
conductor of +90C permits a higher current carrying capacity than PVC insulated power distribution cables.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
551
Energy- and Power Cable / Power Cables / Power cables for energy supply
A-LiY(StE)Y Data transmission cables for petrol stations and refineries with BAM*-test
report
Application
These data transmission cables, oil- and fuel-resistant, are used for internal and external wiring applications at petrol pumps, for data transmission
from the pumps to the cash desk and in the installation of video surveillance systems. These cables are also installed directly in the ground and are
resistant to UV radiation. Special screens over individual cores guarantee good overall screening and ensure an interference-free transmission of control
pulses.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
32597 4 x 0,75 9,0 38,0 105,0 18 32599 8 x 0,75 11,0 68,0 169,0 18
32633 7 x 0,75 10,3 60,0 150,0 18
3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP
552
Energy- and Power Cable / Power Cables / Power cables for energy supply
Application
Energy and data transmission cables for outdoor use, in the soil, water and concrete, where mechanical damage is excluded . For installations in
applications such as gas stations and refineries, where resistance to oils and fuels is required .
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
32592 2 x 1,5 11,0 29,0 180,0 16 32595 5 x 1,5 13,0 72,0 280,0 16
32593 3 x 1,5 11,5 43,0 225,0 16 32596 7 x 1,5 15,5 101,0 370,0 16
32594 4 x 1,5 12,0 58,0 260,0 16
3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP
553
Energy- and Power Cable / Power Cables / Power cables for energy supply
Note
re = round conductor, single-wire
sm = sectional conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
These cables of PVC insulation and lead inner-sheath are installed everywhere, where the danger of chemical reaction of solvents, energy fuels, oils,
gasolines or of that kind in filling stations particularly in petrol pump areas for carburetor propellants, in refining plants and in chemical industries are
to be caused. Suitable for installation under ground, in water, indoor areas and cable conduits.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Continuation
554
Energy- and Power Cable / Power Cables / Power cables for energy supply
3DVVHQGHV.DEHO]XEHKUQGHQ6LHLQ.DSLWHO;
.DEHOVFKXKHn.XSIHU
.DEHOVFKXKHn$OXPLQLXP
555
LOW-VOLTAGE & SAFETY CABLES
556
Energy- and Power Cable / Low Voltage and Security Cables
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
sm = sectional conductor, mutli-wire
J-version = with GN-YE conductor
O-version = without GN-YE conductor
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen
Application
Halogen-free power cables with enhanced characteristics in case of fire are used for applications where harm to human life and damage to property
must be prevented in the event of fire, e. g. in power stations, industrial installations, communal establishments, hotels, airports, underground stations,
railway stations, hospitals department stores, banks, schools theaters, multi-storey buildings, process control centres etc. Suitable for fixed installation
in dry, damp or wet environments, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor
applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of
Q
water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
J type O type cross-sec. app. mm weight app. J type O type cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
53558 1 x 1,5 rm 6,0 14,4 41,0 16 53114 53262 2 x 1,5 re 12,0 29,0 185,0 16
53559 1 x 2,5 rm 6,5 24,0 53,0 14 53115 53263 2 x 2,5 re 12,2 48,0 220,0 14
53100 53248 1 x 4 re 8,0 39,0 68,0 12 53116 53264 2 x 4 re 13,2 77,0 275,0 12
53101 53249 1 x 6 re 9,0 58,0 90,0 10 53117 53265 2 x 6 re 14,1 115,0 335,0 10
53102 53250 1 x 10 re 9,0 96,0 140,0 8 53118 53266 2 x 10 re 16,2 192,0 450,0 8
53103 53251 1 x 16 re 10,0 154,0 190,0 6 53119 53267 2 x 16 re 17,8 307,0 620,0 6
53104 53252 1 x 25 rm 11,0 240,0 290,0 4 53120 53268 2 x 25 rm 21,0 480,0 930,0 4
53105 53253 1 x 35 rm 12,0 336,0 390,0 2
53106 53254 1 x 50 rm 15,0 480,0 510,0 1
53107 53255 1 x 70 rm 17,0 672,0 710,0 2/0
53108 53256 1 x 95 rm 19,0 912,0 960,0 3/0
53109 53257 1 x 120 rm 21,0 1152,0 1200,0 4/0
53110 53258 1 x 150 rm 23,0 1440,0 1480,0 300 kcmil
53111 53259 1 x 185 rm 25,0 1776,0 1910,0 350 kcmil
53112 53260 1 x 240 rm 28,0 2304,0 2370,0 500 kcmil
53113 53261 1 x 300 rm 30,0 2880,0 2970,0 600 kcmil
52485 52486 1 x 400 rm 32,9 3840,0 3957,0 750 kcmil
Continuation
557
Energy- and Power Cable / Low Voltage and Security Cables
558
Energy- and Power Cable / Low Voltage and Security Cables
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
sm = sectional conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen
Application
The power cables with enhanced characteristics in case of fire are used in power stations.
The concentric conductor can be used as a PE or PEN conductor or as screen. Suitable for fixed installation in dry, damp or wet environments, in, above,
on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications and in underground by using
in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC. Q
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
53200 2 x 1,5 / 1,5 re 12,0 53,0 250,0 16 53223 4 x 4 / 4 re 17,5 202,0 480,0 12
53201 2 x 2,5 / 2,5 re 13,0 81,0 280,0 14 53224 4 x 6 / 6 re 19,0 297,0 600,0 10
53202 2 x 4 / 4 re 14,0 122,0 320,0 12 53225 4 x 10 / 10 re 21,5 504,0 850,0 8
53203 2 x 6 / 6 re 15,0 183,0 400,0 10 53226 4 x 16 / 16 re 24,5 797,0 1200,0 6
53204 2 x 10 / 10 re 16,0 311,0 560,0 8 53227 4 x 25 / 16 rm 29,0 1142,0 1800,0 4
53205 2 x 16 / 16 re 19,1 490,0 780,0 6 53228 4 x 35 / 16 rm 29,5 1528,0 2100,0 2
53206 3 x 1,5 / 1,5 re 13,0 67,0 250,0 16 53229 4 x 50 / 25 sm 32,5 2203,0 2800,0 1
53207 3 x 2,5 / 2,5 re 14,0 104,0 320,0 14 53230 4 x 70 / 35 sm 38,0 3082,0 3800,0 2/0
53208 3 x 4 / 4 re 16,5 161,0 400,0 12 53231 4 x 95 / 50 sm 43,5 4208,0 5100,0 3/0
53209 3 x 6 / 6 re 18,0 242,0 500,0 10 53758 4 x 120 / 70 sm 50,5 5388,0 6556,0 4/0
53210 3 x 10 / 10 re 20,0 408,0 750,0 8 53759 4 x 150 / 70 sm 52,1 6540,0 7600,0 300 kcmil
53211 3 x 16 / 16 re 22,5 643,0 1000,0 6 53760 4 x 185 / 95 sm 57,2 8159,0 9370,0 350 kcmil
53212 3 x 25 / 16 rm 27,0 902,0 1600,0 4 53761 4 x 240 / 120 sm 62,6 10546,0 11611,0 500 kcmil
53213 3 x 35 / 16 rm 27,5 1190,0 1900,0 2 53232 7 x 1,5 / 2,5 re 15,0 132,0 320,0 16
53214 3 x 50 / 25 rm 32,3 1723,0 2400,0 1 53239 7 x 2,5 / 2,5 re 15,5 200,0 400,0 14
53215 3 x 70 / 35 sm 35,6 2410,0 3060,0 2/0 53246 7 x 4 / 4 re 18,1 316,0 580,0 12
53216 3 x 95 / 50 sm 39,0 3296,0 4200,0 3/0 53233 10 x 1,5 / 2,5 re 17,2 177,0 420,0 16
53217 3 x 120 / 70 sm 42,0 4236,0 5207,0 4/0 53240 10 x 2,5 / 4 re 18,9 287,0 550,0 14
53218 3 x 150 / 70 sm 43,5 5100,0 5700,0 300 kcmil 53234 12 x 1,5 / 2,5 re 18,4 204,0 460,0 16
53219 3 x 185 / 95 sm 47,4 6383,0 7150,0 350 kcmil 53241 12 x 2,5 / 4 re 19,2 335,0 610,0 14
53220 3 x 240 / 120 sm 53,5 8240,0 9250,0 500 kcmil 53247 12 x 4 / 6 re 22,6 528,0 910,0 12
53221 4 x 1,5 / 1,5 re 13,5 81,0 300,0 16 53235 16 x 1,5 / 4 re 20,0 275,0 686,0 16
53222 4 x 2,5 / 2,5 re 14,5 129,0 380,0 14 53242 16 x 2,5 / 6 re 20,9 450,0 805,0 14
Continuation
559
Energy- and Power Cable / Low Voltage and Security Cables
560
Energy- and Power Cable / Low Voltage and Security Cables
Note
rm = round conductor, multi-wire;
se = sector-shaped conductor, single-wire;
sm = sector-shaped conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen
Application
Halogen-free power cables for energy with enhanced characteristics in case of fire are used for applications where harm to human life and damage
to property must be prevented in the event of fire, e. g. in power stations, industrial installations, communal establishments, hotels, airports, underground
stations, railway stations, hospitals department stores, banks, schools theaters, multi-storey buildings, process control centres etc. Suitable for fixed
installation in dry, damp or wet environments, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable
for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no
accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Q
Part no. No.cores x Outer Alu Weight AWG-No. Part no. No.cores x Outer Alu Weight AWG-No.
J type O type cross-sec. app. mm weight app. J type O type cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
50073 50128 1 x 25 rm 9,9 73,0 132,0 4 50083 50137 3 x 16 rm 16,3 139,0 364,0 6
50074 50129 1 x 35 rm 11,0 102,0 166,0 2 50084 50138 3 x 25 rm 19,6 218,0 530,0 4
50075 50130 1 x 50 rm 12,5 145,0 211,0 1 50085 50139 3 x 35 rm 22,1 305,0 684,0 2
50076 50131 1 x 70 rm 14,1 203,0 283,0 2/0 50086 50140 3 x 35 se 19,0 305,0 486,0 2
50077 50132 1 x 95 rm 16,1 276,0 376,0 3/0 50087 50141 3 x 50 sm 22,4 435,0 655,0 1
50078 50133 1 x 120 rm 17,5 348,0 456,0 4/0 50088 50142 3 x 50 se 21,2 435,0 622,0 1
53562 53553 1 x 150 rm 19,6 435,0 560,0 300 kcmil 50089 50143 3 x 70 sm 26,1 609,0 903,0 2/0
50079 50134 1 x 185 rm 21,8 537,0 697,0 350 kcmil 50090 50144 3 x 70 se 25,2 609,0 859,0 2/0
53561 50135 1 x 240 rm 24,0 696,0 878,0 500 kcmil 50091 50145 3 x 95 sm 29,1 827,0 1174,0 3/0
50080 53554 1 x 300 rm 26,7 870,0 1073,0 600 kcmil 50092 50146 3 x 95 se 27,8 827,0 1115,0 3/0
50081 50136 1 x 400 rm 29,7 1160,0 1347,0 750 kcmil 50093 50147 3 x 120 sm 32,2 1044,0 1446,0 4/0
50082 53555 1 x 500 rm 33,1 1450,0 1705,0 1000 50094 50148 3 x 120 se 30,8 1044,0 1379,0 4/0
kcmil
Continuation
561
Energy- and Power Cable / Low Voltage and Security Cables
562
Energy- and Power Cable / Low Voltage and Security Cables
N2XH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen
Q
Application
Security cables are ideal for use everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a
special significance, e. g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals
and outpatients clinic (DIN VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings,
schools etc. (DIN VDE 0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems.
The cables are suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete.
For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52058 1 x 4 re 8,0 38,0 155,0 12 52063 1 x 35 rm 14,0 336,0 460,0 2
52059 1 x 6 re 9,0 58,0 190,0 10 52064 1 x 50 rm 15,5 480,0 590,0 1
52060 1 x 10 re 10,0 96,0 215,0 8 52065 1 x 70 rm 17,5 672,0 820,0 2/0
52061 1 x 16 re 10,5 154,0 240,0 6 52066 1 x 95 rm 19,5 912,0 1090,0 3/0
52062 1 x 25 rm 13,0 240,0 380,0 4 52067 1 x 120 rm 21,0 1152,0 1350,0 4/0
Continuation
563
Energy- and Power Cable / Low Voltage and Security Cables
N2XH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52068 1 x 150 rm 23,0 1440,0 1650,0 300 kcmil 52093 3 x 120 / 70 rm 45,0 4128,0 5550,0 4/0
52069 1 x 185 rm 25,0 1776,0 2030,0 350 kcmil 52094 3 x 150 / 70 rm 48,5 4992,0 6560,0 300 kcmil
52070 1 x 240 rm 29,0 2304,0 2590,0 500 kcmil 52095 3 x 185 / 95 rm 54,0 6240,0 8240,0 350 kcmil
52071 2 x 1,5 re 11,5 29,0 170,0 16 52096 4 x 1,5 re 12,5 58,0 210,0 16
52072 2 x 2,5 re 12,0 48,0 190,0 14 52097 4 x 2,5 re 13,0 96,0 260,0 14
52073 2 x 4 re 13,0 77,0 260,0 12 52614 4 x 4 re 13,0 154,0 310,0 12
52074 2 x 6 re 14,0 115,0 310,0 10 52615 4 x 6 re 14,5 230,0 410,0 10
52075 2 x 10 re 15,5 192,0 430,0 8 52616 4 x 10 re 16,0 384,0 620,0 8
52076 2 x 16 re 17,5 307,0 600,0 6 52617 4 x 16 re 18,0 614,0 900,0 6
52077 2 x 25 rm 22,0 480,0 930,0 4 52628 4 x 25 rm 23,6 960,0 1600,0 4
52078 3 x 1,5 re 12,0 43,0 170,0 16 52629 4 x 35 rm 26,4 1344,0 2050,0 2
52079 3 x 2,5 re 12,5 72,0 220,0 14 52383 4 x 50 rm 29,5 1920,0 2761,0 1
52080 3 x 4 re 13,5 115,0 290,0 12 52432 4 x 70 rm 34,6 2688,0 3785,0 2/0
52081 3 x 6 re 14,5 173,0 370,0 10 52433 4 x 95 rm 39,0 3648,0 5010,0 3/0
52082 3 x 10 re 16,5 288,0 530,0 8 52434 4 x 120 rm 43,5 4608,0 6135,0 4/0
52083 3 x 16 re 18,5 461,0 760,0 6 52618 5 x 1,5 re 12,0 72,0 210,0 16
52084 3 x 25 rm 23,5 720,0 1160,0 4 52619 5 x 2,5 re 13,0 120,0 280,0 14
52088 3 x 25 / 16 rm 22,5 874,0 1430,0 4 52620 5 x 4 re 14,5 192,0 380,0 12
52085 3 x 35 rm 26,0 1080,0 1560,0 2 52621 5 x 6 re 15,5 288,0 510,0 10
52089 3 x 35 / 16 rm 28,0 1162,0 1810,0 2 52622 5 x 10 re 18,0 480,0 760,0 8
52086 3 x 50 rm 29,0 1440,0 2030,0 1 52623 5 x 16 re 20,0 768,0 1120,0 6
52090 3 x 50 / 25 rm 32,0 1680,0 2340,0 1 52626 5 x 25 rm 24,5 1200,0 1840,0 4
52087 3 x 70 rm 34,0 2016,0 2890,0 2/0 52627 5 x 35 rm 33,5 1680,0 2510,0 2
52091 3 x 70 / 35 rm 35,0 2352,0 3190,0 2/0 52624 7 x 1,5 re 13,0 101,0 250,0 16
52092 3 x 95 / 50 rm 40,0 3216,0 4350,0 3/0 52625 12 x 1,5 re 16,5 173,0 390,0 16
564
Energy- and Power Cable / Low Voltage and Security Cables
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Q
LS0H = Low Smoke Zero Halogen
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications
and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur
in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52098 2 x 1,5 / 1,5 re 13,0 52,0 200,0 16 52101 2 x 6 / 6 re 16,0 182,0 400,0 10
52099 2 x 2,5 / 2,5 re 14,0 80,0 250,0 14 52102 2 x 10 / 10 re 17,5 312,0 570,0 8
52100 2 x 4 / 4 re 15,0 123,0 310,0 12 52103 3 x 1,5 / 1,5 re 13,0 66,0 220,0 16
Continuation
565
Energy- and Power Cable / Low Voltage and Security Cables
566
Energy- and Power Cable / Low Voltage and Security Cables
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen
Q
Application
Security cables are ideal for use everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a
special significance, e. g. in industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals
and outpatients clinic (DIN VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings,
schools etc. (DIN VDE 0108), mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems.
The cables are suitable for fixed installation in dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete.
These cables are suitable for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must
be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52700 1 x 4 re 7,0 38,0 98,0 12 52707 1 x 70 rm 15,0 672,0 800,0 2/0
52701 1 x 6 re 7,5 58,0 125,0 10 52708 1 x 95 rm 16,5 912,0 1100,0 3/0
52702 1 x 10 re 8,0 96,0 165,0 8 52709 1 x 120 rm 18,5 1152,0 1350,0 4/0
52703 1 x 16 rm 9,0 154,0 230,0 6 52710 1 x 150 rm 20,5 1440,0 1650,0 300 kcmil
52704 1 x 25 rm 10,5 240,0 345,0 4 52711 1 x 185 rm 23,0 1776,0 2000,0 350 kcmil
52705 1 x 35 rm 11,5 336,0 450,0 2 52712 1 x 240 rm 25,5 2304,0 2650,0 500 kcmil
52706 1 x 50 rm 12,0 480,0 590,0 1 52713 1 x 300 rm 31,8 2880,0 3200,0 600 kcmil
Continuation
567
Energy- and Power Cable / Low Voltage and Security Cables
568
Energy- and Power Cable / Low Voltage and Security Cables
(N)HXCH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LS0H = Low Smoke Zero Halogen Q
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications
and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur
in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52900 2 x 1,5 / 1,5 re 13,0 52,0 220,0 16 52907 3 x 4 / 4 re 15,5 161,0 530,0 12
52901 2 x 2,5 / 2,5 re 13,5 80,0 385,0 14 52908 3 x 6 / 6 re 16,5 240,0 630,0 10
52902 2 x 4 / 4 re 14,5 123,0 470,0 10 52909 3 x 10 / 10 re 18,5 408,0 850,0 8
52903 2 x 6 / 6 re 16,0 182,0 550,0 10 52910 3 x 16 / 16 rm 20,5 643,0 1150,0 6
52904 2 x 10 / 10 re 18,0 312,0 730,0 8 52911 3 x 25 / 16 rm 24,0 902,0 1700,0 4
52905 3 x 1,5 / 1,5 re 13,5 66,0 380,0 16 52912 3 x 35 / 16 rm 26,5 1190,0 2150,0 2
52906 3 x 2,5 / 2,5 re 14,5 104,0 430,0 14 52913 3 x 50 / 25 rm 29,5 1723,0 2800,0 1
Continuation
569
Energy- and Power Cable / Low Voltage and Security Cables
(N)HXCH-FE 180/E 30 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52914 3 x 70 / 35 rm 33,0 2410,0 3800,0 2/0 52930 4 x 95 / 50 rm 41,5 4208,0 5750,0 3/0
52915 3 x 95 / 50 rm 37,5 3296,0 5100,0 3/0 52931 4 x 120 / 70 rm 47,0 5388,0 7100,0 4/0
52916 3 x 120 / 70 rm 42,5 4236,0 6250,0 4/0 52932 4 x 150 / 70 rm 52,0 6558,0 8550,0 300 kcmil
52917 3 x 150 / 70 rm 47,0 5100,0 6900,0 300 kcmil 52933 4 x 185 / 95 rm 58,0 8159,0 10700,0 350 kcmil
52918 3 x 185 / 95 rm 52,5 6383,0 8550,0 350 kcmil 52934 4 x 240 / 120 rm 64,0 10546,0 13930,0 500 kcmil
52919 3 x 240 / 120 rm 58,5 8242,0 11150,0 500 kcmil 52935 7 x 1,5 / 2,5 re 16,5 133,0 635,0 16
52920 4 x 1,5 / 1,5 re 14,5 81,0 435,0 16 52936 7 x 2,5 / 2,5 re 17,5 200,0 680,0 14
52921 4 x 2,5 / 2,5 re 15,5 128,0 500,0 14 52937 10 x 1,5 / 2,5 re 19,5 176,0 870,0 16
52922 4 x 4 / 4 re 16,5 200,0 610,0 12 52938 10 x 2,5 / 4 re 21,0 286,0 980,0 14
52923 4 x 6 / 6 re 17,5 297,0 740,0 10 52939 12 x 1,5 / 2,5 re 20,0 205,0 1050,0 16
52924 4 x 10 / 10 re 20,0 504,0 1050,0 8 52940 12 x 2,5 / 4 re 21,5 334,0 1050,0 14
52925 4 x 16 / 16 re 22,0 796,0 1350,0 6 52941 24 x 1,5 / 6 re 26,0 413,0 1900,0 16
52926 4 x 25 / 16 rm 26,0 1142,0 1950,0 4 52942 24 x 2,5 / 10 re 28,5 696,0 1900,0 14
52927 4 x 35 / 16 rm 28,5 1526,0 2400,0 2 52943 30 x 1,5 / 6 re 27,0 499,0 2200,0 16
52928 4 x 50 / 25 rm 32,0 2203,0 3200,0 1 52944 30 x 2,5 / 10 re 30,0 840,0 2200,0 14
52929 4 x 70 / 35 rm 37,0 3082,0 4300,0 2/0
570
Energy- and Power Cable / Low Voltage and Security Cables
N2XH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LSOH = Low Smoke Zero Halogen
Q
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications
and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur
in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52534 1 x 16 rm 11,5 154,0 250,0 6 52538 1 x 70 rm 17,5 672,0 840,0 2/0
52535 1 x 25 rm 13,0 240,0 360,0 4 52539 1 x 95 rm 19,5 912,0 1120,0 3/0
52536 1 x 35 rm 14,0 336,0 460,0 2 52540 1 x 120 rm 21,5 1152,0 1390,0 4/0
52537 1 x 50 rm 15,5 480,0 610,0 1 52541 1 x 150 rm 23,5 1440,0 1690,0 300 kcmil
Continuation
571
Energy- and Power Cable / Low Voltage and Security Cables
N2XH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52542 1 x 185 rm 25,5 1776,0 2090,0 350 kcmil 52583 4 x 6 re 19,5 230,0 630,0 10
52899 1 x 240 rm 28,5 2304,0 2660,0 500 kcmil 52584 4 x 10 rm 22,5 384,0 880,0 8
52543 1 x 300 rm 31,0 2880,0 3350,0 600 kcmil 52585 4 x 16 rm 24,5 614,0 1180,0 6
52544 1 x 400 rm 34,5 3840,0 4230,0 750 kcmil 52586 4 x 25 rm 28,5 960,0 1730,0 4
52545 2 x 1,5 re 14,5 29,0 270,0 16 52587 4 x 35 rm 31,0 1344,0 2220,0 2
52546 2 x 2,5 re 15,5 48,0 310,0 14 52588 4 x 50 rm 35,0 1920,0 2940,0 1
52547 2 x 4 re 16,5 77,0 370,0 12 52589 4 x 70 rm 39,0 2688,0 3960,0 2/0
52548 2 x 6 re 17,5 115,0 440,0 10 52590 4 x 95 rm 45,0 3648,0 5360,0 3/0
52549 2 x 10 rm 19,5 192,0 600,0 8 52591 4 x 120 rm 48,5 4608,0 6550,0 4/0
52550 2 x 16 rm 21,0 307,0 780,0 6 52592 4 x 150 rm 54,0 5760,0 8070,0 300 kcmil
52551 2 x 25 rm 23,5 480,0 1100,0 4 52593 4 x 185 rm 59,0 7104,0 9970,0 350 kcmil
52552 2 x 35 rm 26,5 672,0 1400,0 2 52594 4 x 240 rm 66,0 9216,0 12830,0 500 kcmil
52553 2 x 50 rm 30,0 960,0 1830,0 1 52595 5 x 1,5 re 18,0 72,0 420,0 16
52554 2 x 70 rm 33,0 1344,0 2420,0 2/0 52596 5 x 2,5 re 19,0 120,0 500,0 14
52555 2 x 95 rm 37,5 1824,0 3240,0 3/0 52597 5 x 4 re 20,0 192,0 610,0 12
52556 2 x 120 rm 41,0 2304,0 3940,0 4/0 52598 5 x 6 re 21,5 288,0 760,0 10
52557 3 x 1,5 re 15,0 43,0 260,0 16 52599 5 x 10 rm 24,5 480,0 1070,0 8
52558 3 x 2,5 re 16,0 72,0 350,0 14 52600 5 x 16 rm 27,0 768,0 1450,0 6
52559 3 x 4 re 17,0 115,0 420,0 12 52601 5 x 25 rm 31,0 1200,0 2120,0 4
52560 3 x 6 re 18,0 173,0 520,0 10 52602 5 x 35 rm 34,0 1680,0 2730,0 2
52561 3 x 10 rm 20,5 288,0 710,0 8 52603 5 x 50 rm 38,5 2400,0 3620,0 1
52562 3 x 16 rm 22,5 461,0 950,0 6 52604 5 x 70 rm 43,5 3360,0 4940,0 2/0
52563 3 x 25 rm 26,0 720,0 1370,0 4 52605 7 x 1,5 re 19,5 101,0 480,0 16
52564 3 x 35 rm 28,0 1008,0 1750,0 2 52606 7 x 2,5 re 20,5 168,0 580,0 14
52572 3 x 35 / 16 rm 29,5 1162,0 1950,0 2 52607 7 x 4 re 22,0 269,0 730,0 12
52565 3 x 50 rm 32,0 1440,0 2310,0 1 52608 10 x 1,5 re 24,0 144,0 650,0 16
52573 3 x 50 / 25 rm 33,5 1680,0 2640,0 1 52609 10 x 2,5 re 25,5 240,0 790,0 14
52566 3 x 70 rm 35,5 2016,0 3100,0 2/0 52610 12 x 1,5 re 24,5 173,0 720,0 16
52574 3 x 70 / 35 rm 37,0 2352,0 3520,0 2/0 52611 12 x 2,5 re 26,0 288,0 890,0 14
52567 3 x 95 rm 40,5 2736,0 4180,0 3/0 52612 24 x 1,5 re 33,0 346,0 1270,0 16
52575 3 x 95 / 50 rm 42,0 3216,0 4710,0 3/0
52568 3 x 120 rm 44,0 3456,0 5130,0 4/0
52576 3 x 120 / 70 rm 46,5 4128,0 5910,0 4/0
52569 3 x 150 rm 48,5 4320,0 6260,0 300 kcmil
52577 3 x 150 / 70 rm 50,0 4992,0 6970,0 300 kcmil
52570 3 x 185 rm 53,0 5328,0 7720,0 350 kcmil
52578 3 x 185 / 95 rm 55,5 6240,0 8750,0 350 kcmil
52571 3 x 240 rm 59,5 6912,0 9990,0 500 kcmil
52579 3 x 240 / 120 rm 61,5 8064,0 11180,0 500 kcmil
52580 4 x 1,5 re 16,5 58,0 350,0 16
52581 4 x 2,5 re 17,5 96,0 420,0 14
52582 4 x 4 re 18,5 154,0 510,0 12
572
Energy- and Power Cable / Low Voltage and Security Cables
N2XCH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LSOH = Low Smoke Zero Halogen
Q
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications
and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur
in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52771 3 x 1,5 / 1,5 re 16,5 66,0 330,0 16 52776 3 x 16 / 16 rm 24,5 643,0 1130,0 6
52772 3 x 2,5 / 2,5 re 17,5 104,0 400,0 14 52777 3 x 25 / 16 rm 28,0 902,0 1560,0 4
52773 3 x 4 / 4 re 18,5 161,0 480,0 12 52778 3 x 35 / 16 rm 30,5 1190,0 1960,0 2
52774 3 x 6 / 6 re 20,0 240,0 600,0 10 52779 3 x 50 / 25 rm 34,0 1723,0 2610,0 1
52775 3 x 10 / 10 rm 22,0 408,0 840,0 8 52780 3 x 70 / 35 rm 37,5 2410,0 3500,0 2/0
Continuation
573
Energy- and Power Cable / Low Voltage and Security Cables
N2XCH-FE 180/E 90 security cable, halogen-free, 0,6/1 kV, with improved fire
characteristics
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
52781 3 x 95 / 50 rm 43,0 3296,0 4700,0 3/0 52795 4 x 70 / 35 rm 41,5 3082,0 4360,0 2/0
52782 3 x 120 / 70 rm 48,0 4236,0 5880,0 4/0 52796 4 x 95 / 50 rm 47,5 4208,0 5900,0 3/0
52783 3 x 150 / 70 rm 52,0 4992,0 7300,0 300 kcmil 52797 4 x 120 / 70 rm 52,5 5388,0 7340,0 4/0
52784 3 x 185 / 95 rm 57,5 6383,0 8760,0 350 kcmil 52798 4 x 150 / 70 rm 57,5 6540,0 8840,0 300 kcmil
52785 3 x 240 / 120 rm 63,5 8242,0 11280,0 500 kcmil 52799 4 x 185 / 95 rm 63,5 8159,0 11020,0 350 kcmil
52786 4 x 1,5 / 1,5 re 17,5 81,0 390,0 16 52800 4 x 240 / 120 rm 70,0 10546,0 14140,0 500 kcmil
52787 4 x 2,5 / 2,5 re 19,0 128,0 470,0 14 52801 7 x 1,5 / 2,5 re 20,5 133,0 520,0 16
52788 4 x 4 / 4 re 20,0 200,0 570,0 12 52805 7 x 2,5 / 2,5 re 22,0 200,0 630,0 14
52789 4 x 6 / 6 re 21,5 297,0 720,0 10 52802 12 x 1,5 / 2,5 re 26,0 205,0 770,0 16
52790 4 x 10 / 10 rm 24,0 504,0 1010,0 8 52806 12 x 2,5 / 4 re 28,0 334,0 950,0 14
52791 4 x 16 / 16 rm 26,5 796,0 1370,0 6 52803 24 x 1,5 / 6 re 35,0 413,0 1380,0 16
52792 4 x 25 / 16 rm 30,5 1142,0 1940,0 4 52807 24 x 2,5 / 10 re 37,5 696,0 1750,0 14
52793 4 x 35 / 16 rm 33,0 1526,0 2420,0 2 52804 30 x 1,5 / 6 re 37,0 499,0 1630,0 16
52794 4 x 50 / 25 rm 37,5 2203,0 3240,0 1 52808 30 x 2,5 / 10 re 39,5 840,0 2080,0 14
574
Energy- and Power Cable / Low Voltage and Security Cables
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LSOH = Low Smoke Zero Halogen
Q
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications
and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur
in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
53180 1 x 16 rm 11,0 154,0 255,0 6 53188 1 x 185 rm 24,5 1776,0 2140,0 350 kcmil
53181 1 x 25 rm 12,5 240,0 375,0 4 53189 1 x 240 rm 27,0 2304,0 2700,0 500 kcmil
53182 1 x 35 rm 13,5 336,0 475,0 2 53190 1 x 300 rm 30,0 2880,0 3420,0 600 kcmil
53183 1 x 50 rm 15,0 480,0 625,0 1 53191 1 x 400 rm 33,5 3840,0 4310,0 750 kcmil
53184 1 x 70 rm 16,5 672,0 855,0 2/0 53000 3 x 1,5 re 14,0 43,0 280,0 16
53185 1 x 95 rm 18,0 912,0 1140,0 3/0 53001 3 x 2,5 re 15,0 72,0 330,0 14
53186 1 x 120 rm 20,5 1152,0 1410,0 4/0 53002 3 x 4 re 16,0 115,0 400,0 12
53187 1 x 150 rm 22,5 1440,0 1730,0 300 kcmil 53003 3 x 6 re 17,0 173,0 480,0 10
Continuation
575
Energy- and Power Cable / Low Voltage and Security Cables
576
Energy- and Power Cable / Low Voltage and Security Cables
Note
re = round conductor, single-wire
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
LSOH = Low Smoke Zero Halogen
Q
Application
Everywhere, where in case of fire human life and material assets are to be protected and safety conciousness take a special significance, e. g. in
industrial complexes, power stations, communal establishment, hotels, airports, underground railway networks, hospitals and outpatients clinic (DIN
VDE 0107), department stores, data processing centres, theaters, cinemas, in multi-storey buildings, public gatherings, schools etc. (DIN VDE 0108),
mining works, offshore plants, leading centres, traffic communication, emergency power supply and alarm systems. Suitable for fixed installation in
dry and moist rooms, in, above, on and beneath plaster as well as in masonary walls and in concrete. For the installation in conduit all precautions
must be taken that no accumulation of water can occur in the pipes.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
59028 2 x 2,5 / 2,5 re 16,0 80,0 390,0 14 53041 3 x 70 / 35 rm 38,0 2410,0 3800,0 2/0
53032 3 x 1,5 / 1,5 re 16,9 66,0 380,0 16 53042 3 x 95 / 50 rm 44,0 3296,0 5100,0 3/0
53033 3 x 2,5 / 2,5 re 18,0 104,0 430,0 14 53043 3 x 120 / 70 rm 47,0 4236,0 6250,0 4/0
53034 3 x 4 / 4 re 19,0 161,0 530,0 12 53044 3 x 150 / 70 rm 51,0 4992,0 6900,0 300 kcmil
53035 3 x 6 / 6 re 20,1 240,0 640,0 10 53045 3 x 185 / 95 rm 56,0 6383,0 8550,0 350 kcmil
53036 3 x 10 / 10 re 22,0 408,0 850,0 8 53046 3 x 240 / 120 rm 65,0 8242,0 11150,0 500 kcmil
53037 3 x 16 / 16 rm 24,0 643,0 1150,0 6
53038 3 x 25 / 16 rm 28,0 902,0 1700,0 4
53039 3 x 35 / 16 rm 30,0 1190,0 2150,0 2
53040 3 x 50 / 25 rm 34,0 1723,0 2800,0 1
Continuation
577
Energy- and Power Cable / Low Voltage and Security Cables
578
Energy- and Power Cable / Low Voltage and Security Cables
Application
Flame resistant, halogen-free, static screened installation cables for telecommunication purpose. The static screen prevents strong interference impulse.
Q
Suitable for fixed installation everywhere, where in case of fire human life and material assets are to be protected and a safety conciousness take a
special significance, e. g. in industrial complexes, public buildings, hotels, airports, under ground railway networks, hospitals.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Functionality E 30 to E 90 Functionality E 30
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
34081 2 x 2 x 0,8 7,4 25,0 74,0 - 34148 2 x 2 x 0,8 7,5 25,0 74,0 -
34082 4 x 2 x 0,8 10,8 45,0 127,0 - 34149 4 x 2 x 0,8 9,3 45,0 127,0 -
34083 8 x 2 x 0,8 16,9 85,0 300,0 - 34150 8 x 2 x 0,8 11,4 85,0 300,0 -
34084 12 x 2 x 0,8 18,5 126,0 336,0 - 34151 12 x 2 x 0,8 13,0 126,0 336,0 -
34085 16 x 2 x 0,8 20,1 166,0 426,0 - 34152 16 x 2 x 0,8 15,7 166,0 426,0 -
34086 20 x 2 x 0,8 22,2 206,0 529,0 - 34153 20 x 2 x 0,8 16,5 206,0 529,0 -
34087 32 x 2 x 0,8 29,1 326,0 859,0 - 34154 32 x 2 x 0,8 20,3 326,0 859,0 -
34088 40 x 2 x 0,8 34,2 407,0 1094,0 - 34155 40 x 2 x 0,8 23,4 407,0 1094,0 -
34089 52 x 2 x 0,8 37,3 529,0 1280,0 - 34156 52 x 2 x 0,8 25,2 529,0 1280,0 -
579
Energy- and Power Cable / Low Voltage and Security Cables
Application
Static screened installation cables for telecommunication purposes. The static screen prevents strong interference impulse. Suitable for fixed installation
everywhere, where in case of fire human life and material assets are to be protected and a safety conciousness take a special significance, e. g. in
industrial complexes, public buildings, hotels, airports, under ground railway networks, hospitals.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Functionality E 30 to E 90 Functionality E 30
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
34091 2 x 2 x 0,8 7,4 25,0 74,0 - 34157 2 x 2 x 0,8 7,5 25,0 67,0 -
34092 4 x 2 x 0,8 10,8 45,0 127,0 - 34158 4 x 2 x 0,8 9,3 45,0 103,0 -
34093 8 x 2 x 0,8 16,9 85,0 300,0 - 34159 8 x 2 x 0,8 11,4 85,0 168,0 -
34094 12 x 2 x 0,8 18,5 126,0 336,0 - 34160 12 x 2 x 0,8 13,0 126,0 237,0 -
34095 16 x 2 x 0,8 20,1 166,0 426,0 - 34161 16 x 2 x 0,8 15,7 166,0 303,0 -
34096 20 x 2 x 0,8 22,2 206,0 529,0 - 34162 20 x 2 x 0,8 16,5 206,0 361,0 -
34097 32 x 2 x 0,8 29,1 326,0 859,0 - 34163 32 x 2 x 0,8 20,3 326,0 553,0 -
34098 40 x 2 x 0,8 34,2 407,0 1094,0 - 34164 40 x 2 x 0,8 23,4 407,0 699,0 -
34099 52 x 2 x 0,8 37,3 529,0 1280,0 - 34165 52 x 2 x 0,8 25,2 529,0 865,0 -
580
Energy- and Power Cable / Low Voltage and Security Cables
Application Q
Wherever necessary to prevent high property value in case of fire damage to human and material. The static screen prevents strong interference
impulse. Suitable for fixed installation everywhere, where in case of fire human life and material assets are to be protected and a safety conciousness
take a special significance, e. g. in industrial complexes, public buildings, hotels, airports, under ground railway networks, hospitals.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x Outer Cop. Weight Part no. No.pairs x Outer Cop. Weight
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
34075 2 x 2 x 0,8 11,7 25,0 150,0 - 34080 20 x 2 x 0,8 28,9 206,0 870,0 -
34076 4 x 2 x 0,8 15,7 45,0 275,0 - 34072 32 x 2 x 0,8 41,1 326,0 1360,0 -
34077 8 x 2 x 0,8 21,6 85,0 545,0 - 34073 40 x 2 x 0,8 42,3 407,0 1800,0 -
34078 12 x 2 x 0,8 23,8 126,0 602,0 - 34074 52 x 2 x 0,8 45,2 529,0 2038,0 -
34079 16 x 2 x 0,8 27,7 166,0 734,0 -
581
MEDIUM-VOLTAGE CABLES
582
MEDIUM VOLTAGE POWER CABLES
XLPE-insulated 6/10 kV, 12/20 kV, 18/30 kV
Specific heat resistance 3,5 K m/W PE compound DMP2 according to HD 620 S2 black or
PVC compound DMV6 according to HD 620 S2 red
Q
Dielectric constant 2,4
Specific resistance (20C) min. 1016 Ohm cm Wall-thickness = 2,5 mm,
Loss factor (tan ) (20C) max. 0,5 103 for 1x 500 mm2 /30 kV = 2,6 mm
Density 0,92 g/cm3
Breaking strength min. 200%
Tensile strength min. 12,5 N/mm2
Conductor
Copper or aluminium, round, multiwire stranded
and compact, according to VDE 0295.
583
MEDIUM VOLTAGE POWER CABLES
XLPE-insulated 6/10 kV, 12/20 kV, 18/30 kV
U0/U = 12/20 kV
U0/U = 18/30 kV
U0/U = 6/10 kV
touching or triangular shape.
For laying in conduits, the influence of thermal
insulation of air space between the cable and the inner
wall of conduit should be specially considered. The inner
diameter of the conduit should be at least 1,5 times that
of the diameter of the cable.
Voltage test a. c. in kV 15 30 45
Bending radius
During the laying of XLPE cables, the bending radius Voltage test d. c. in kV 48 96 144
should not be below of the following values:
Cable without metal sheath = 15 x cable
Cable with Alu-laminated sheath = 30 x cable Voltage test a. c. 18 36 54
(voltage test = 1000 h)
Temperature range
During the installation, the temperature should not be
below the following values: Voltage test to cable system
for XLPE-insulation + PVC sheath = 5C
for XLPE-insulation + PE sheath = 20C During the operation or after laying the medium
voltage power cables, the dielectric can be tested with
Max. permissible tensile strength alternating or direct current. The test duration continues
30 minutes.
By pulling the conductors with a pulling head (not
for armoured cables) Kind of U0/U = 12/20 kV
U0/U = 18/30 kV
voltage test
U0/U = 6/10 kV
Laying in air
Air temperature 30C
Load factor (permanent load) 1,0
584
Energy- and Power Cable / Medium Voltage Power Cables
Application
Suitable for installation mostly for power supply stations, in indoors and in cable ducts,outdoor with protected laying, underground and in water as
well as for installation on cable trays for industries, switch-boards and power stations. Due to the good laying characteristic, this can also be laid easily
in difficult line guideways. The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer
on the XLPE insulation assures a construction free of partial discharges with high operational reliability.
Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32400 1 x 35 rm / 16 12 6 / 10 3,4 2,5 23,0 - 28,0 518,0 905,0 2
32401 1 x 50 rm / 16 12 6 / 10 3,4 2,5 24,0 - 29,0 662,0 1080,0 1
32402 1 x 70 rm / 16 12 6 / 10 3,4 2,5 26,0 - 31,0 854,0 1310,0 2/0
32403 1 x 95 rm / 16 12 6 / 10 3,4 2,5 26,0 - 32,0 1094,0 1580,0 3/0
32404 1 x 120 rm / 16 12 6 / 10 3,4 2,5 28,0 - 34,0 1334,0 1860,0 4/0
32405
32406
32407
1 x 150
1 x 150
1 x 185
rm / 16
rm / 25
rm / 16
12
12
12
6 / 10
6 / 10
6 / 10
3,4
3,4
3,4
2,5
2,5
2,5
29,0 - 35,0
29,0 - 35,0
31,0 - 37,0
1622,0
1723,0
1958,0
2040,0
2210,0
2450,0
300 kcmil
300 kcmil
350 kcmil
Q
32408 1 x 185 rm / 25 12 6 / 10 3,4 2,5 31,0 - 37,0 2059,0 2580,0 350 kcmil
32409 1 x 240 rm / 16 12 6 / 10 3,4 2,5 33,0 - 39,0 2486,0 3000,0 500 kcmil
32410 1 x 240 rm / 25 12 6 / 10 3,4 2,5 33,0 - 39,0 2587,0 3130,0 500 kcmil
32411 1 x 300 rm / 25 12 6 / 10 3,4 2,5 36,0 - 41,0 3163,0 3780,0 600 kcmil
32412 1 x 400 rm / 35 12 6 / 10 3,4 2,5 40,0 - 45,0 4234,0 4670,0 750 kcmil
32413 1 x 500 rm / 35 12 6 / 10 3,4 2,5 43,0 - 48,0 5194,0 5750,0 1000 kcmil
33099 1 x 630 rm / 35 12 6 / 10 3,4 2,5 44,0 - 49,0 6442,0 7180,0 1250 kcmil
32414 1 x 35 rm / 16 24 12 / 20 5,5 2,5 27,0 - 32,0 518,0 1110,0 2
32415 1 x 50 rm / 16 24 12 / 20 5,5 2,5 28,0 - 33,0 662,0 1250,0 1
32416 1 x 70 rm / 16 24 12 / 20 5,5 2,5 30,0 - 35,0 854,0 1510,0 2/0
32417 1 x 95 rm / 16 24 12 / 20 5,5 2,5 31,0 - 36,0 1094,0 1780,0 3/0
32418 1 x 120 rm / 16 24 12 / 20 5,5 2,5 32,0 - 38,0 1334,0 2070,0 4/0
32419 1 x 150 rm / 16 24 12 / 20 5,5 2,5 33,0 - 39,0 1622,0 2310,0 300 kcmil
32420 1 x 150 rm / 25 24 12 / 20 5,5 2,5 33,0 - 39,0 1723,0 2420,0 300 kcmil
32421 1 x 185 rm / 16 24 12 / 20 5,5 2,5 35,0 - 41,0 1958,0 2650,0 350 kcmil
32422 1 x 185 rm / 25 24 12 / 20 5,5 2,5 35,0 - 41,0 2059,0 2810,0 350 kcmil
32423 1 x 240 rm / 16 24 12 / 20 5,5 2,5 38,0 - 44,0 2486,0 3260,0 500 kcmil
32424 1 x 240 rm / 25 24 12 / 20 5,5 2,5 38,0 - 44,0 2587,0 3360,0 500 kcmil
32425 1 x 300 rm / 25 24 12 / 20 5,5 2,5 40,0 - 46,0 3163,0 4020,0 600 kcmil
32426 1 x 400 rm / 35 24 12 / 20 5,5 2,5 43,0 - 49,0 4234,0 4930,0 750 kcmil
32427 1 x 500 rm / 35 24 12 / 20 5,5 2,5 46,0 - 52,0 5194,0 6050,0 1000 kcmil
33096 1 x 630 rm / 35 24 12 / 20 5,5 2,5 47,0 - 53,0 6442,0 7510,0 1250 kcmil
Continuation
585
Energy- and Power Cable / Medium Voltage Power Cables
586
Energy- and Power Cable / Medium Voltage Power Cables
Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer sheath is resistant to high mechanical stress for laying the cables. This PE-sheath is not flame retardant
acc. to DIN EN 60332-1-2.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.
Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32480 1 x 35 rm / 16 12 6 / 10 3,4 2,5 23,0 - 28,0 518,0 910,0 2
32481 1 x 50 rm / 16 12 6 / 10 3,4 2,5 24,0 - 29,0 662,0 990,0 1
32482 1 x 70 rm / 16 12 6 / 10 3,4 2,5 26,0 - 31,0 854,0 1205,0 2/0
32483 1 x 95 rm / 16 12 6 / 10 3,4 2,5 26,0 - 32,0 1098,0 1520,0 3/0
32484 1 x 120 rm / 16 12 6 / 10 3,4 2,5 28,0 - 34,0 1334,0 1760,0 4/0
32485
32486
32487
1 x 150
1 x 150
1 x 185
rm / 16
rm / 25
rm / 16
12
12
12
6 / 10
6 / 10
6 / 10
3,4
3,4
3,4
2,5
2,5
2,5
29,0 - 35,0
29,0 - 35,0
31,0 - 37,0
1622,0
1725,0
1958,0
2020,0
2130,0
2360,0
300 kcmil
300 kcmil
350 kcmil
Q
32488 1 x 185 rm / 25 12 6 / 10 3,4 2,5 31,0 - 37,0 2059,0 2470,0 350 kcmil
32489 1 x 240 rm / 16 12 6 / 10 3,4 2,5 33,0 - 39,0 2486,0 2960,0 500 kcmil
32490 1 x 240 rm / 25 12 6 / 10 3,4 2,5 33,0 - 39,0 2587,0 3020,0 500 kcmil
32491 1 x 300 rm / 25 12 6 / 10 3,4 2,5 36,0 - 41,0 3163,0 3630,0 600 kcmil
32492 1 x 400 rm / 35 12 6 / 10 3,4 2,5 40,0 - 45,0 4234,0 4560,0 750 kcmil
32493 1 x 500 rm / 35 12 6 / 10 3,4 2,5 43,0 - 48,0 5194,0 5580,0 1000 kcmil
32494 1 x 35 rm / 16 24 12 / 20 5,5 2,5 27,0 - 32,0 518,0 960,0 2
32495 1 x 50 rm / 16 24 12 / 20 5,5 2,5 28,0 - 33,0 662,0 1160,0 1
32496 1 x 70 rm / 16 24 12 / 20 5,5 2,5 30,0 - 35,0 854,0 1410,0 2/0
32497 1 x 95 rm / 16 24 12 / 20 5,5 2,5 31,0 - 36,0 1094,0 1670,0 3/0
32498 1 x 120 rm / 16 24 12 / 20 5,5 2,5 33,0 - 38,0 1334,0 1960,0 4/0
32499 1 x 150 rm / 16 24 12 / 20 5,5 2,5 34,0 - 39,0 1622,0 2220,0 300 kcmil
32500 1 x 150 rm / 25 24 12 / 20 5,5 2,5 34,0 - 39,0 1723,0 2310,0 300 kcmil
32501 1 x 185 rm / 16 24 12 / 20 5,5 2,5 36,0 - 41,0 1958,0 2620,0 350 kcmil
32502 1 x 185 rm / 25 24 12 / 20 5,5 2,5 36,0 - 41,0 2059,0 2670,0 350 kcmil
32503 1 x 240 rm / 16 24 12 / 20 5,5 2,5 39,0 - 44,0 2486,0 3160,0 500 kcmil
32504 1 x 240 rm / 25 24 12 / 20 5,5 2,5 39,0 - 44,0 2587,0 3270,0 500 kcmil
32505 1 x 300 rm / 25 24 12 / 20 5,5 2,5 41,0 - 46,0 3163,0 3880,0 600 kcmil
32506 1 x 400 rm / 35 24 12 / 20 5,5 2,5 44,0 - 49,0 4234,0 4820,0 750 kcmil
32507 1 x 500 rm / 35 24 12 / 20 5,5 2,5 47,0 - 52,0 5194,0 5860,0 1000 kcmil
32508 1 x 50 rm / 16 36 18 / 30 8 2,5 32,0 - 38,0 662,0 1410,0 1
32509 1 x 70 rm / 16 36 18 / 30 8 2,5 34,0 - 40,0 854,0 1660,0 2/0
Continuation
587
Energy- and Power Cable / Medium Voltage Power Cables
588
Energy- and Power Cable / Medium Voltage Power Cables
Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer sheath is resistant to high mechanical stress for laying the cables. This PE sheath is not flame retardant
acc. to DIN EN 60332-1-2.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.
Part no. No.cores x Operation Nominal Insulation Screen Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. thickness app. mm weight app. kg / km
mm max. kV mm mm Nominal kg / km
value
mm
32560 1 x 35 rm / 16 12 6 / 10 3,4 16 2,5 26,0 518,0 1050,0 2
32561 1 x 50 rm / 16 12 6 / 10 3,4 16 2,5 28,0 662,0 1150,0 1
32562 1 x 70 rm / 16 12 6 / 10 3,4 16 2,5 30,0 854,0 1460,0 2/0
32563 1 x 95 rm / 16 12 6 / 10 3,4 16 2,5 31,0 1094,0 1700,0 3/0
32564
32565
1 x 120
1 x 150
rm / 16
rm / 25
12
12
6 / 10
6 / 10
3,4
3,4
16
25
2,5
2,5
32,0
34,0
1334,0
1723,0
2030,0
2350,0
4/0
300 kcmil
Q
32566 1 x 185 rm / 25 12 6 / 10 3,4 25 2,5 36,0 2059,0 2700,0 350 kcmil
32567 1 x 240 rm / 25 12 6 / 10 3,4 25 2,5 38,0 2587,0 3300,0 500 kcmil
32568 1 x 300 rm / 25 12 6 / 10 3,4 25 2,5 40,0 3163,0 3900,0 600 kcmil
32569 1 x 400 rm / 35 12 6 / 10 3,4 35 2,5 44,0 4234,0 4850,0 750 kcmil
32570 1 x 500 rm / 35 12 6 / 10 3,4 35 2,5 47,0 5194,0 6000,0 1000 kcmil
79954 1 x 630 rm / 35 12 6 / 10 3,4 35 2,5 49,0 6442,0 7020,0 1250 kcmil
32571 1 x 35 rm / 16 24 12 / 20 5,5 16 2,5 31,0 518,0 1210,0 2
32572 1 x 50 rm / 16 24 12 / 20 5,5 16 2,5 33,0 662,0 1400,0 1
32573 1 x 70 rm / 16 24 12 / 20 5,5 16 2,5 34,0 854,0 1550,0 2/0
32574 1 x 95 rm / 16 24 12 / 20 5,5 16 2,5 36,0 1094,0 1800,0 3/0
32575 1 x 120 rm / 16 24 12 / 20 5,5 16 2,5 37,0 1334,0 2150,0 4/0
32576 1 x 150 rm / 25 24 12 / 20 5,5 25 2,5 39,0 1723,0 2400,0 300 kcmil
32577 1 x 185 rm / 25 24 12 / 20 5,5 25 2,5 41,0 2059,0 2850,0 350 kcmil
32578 1 x 240 rm / 25 24 12 / 20 5,5 25 2,5 43,0 2587,0 3250,0 500 kcmil
32579 1 x 300 rm / 25 24 12 / 20 5,5 25 2,5 45,0 3163,0 3850,0 600 kcmil
32580 1 x 400 rm / 35 24 12 / 20 5,5 35 2,5 48,0 4234,0 4900,0 750 kcmil
32581 1 x 500 rm / 35 24 12 / 20 5,5 35 2,5 52,0 5194,0 6100,0 1000 kcmil
33092 1 x 630 rm / 35 24 12 / 20 5,5 35 2,5 54,0 6442,0 7340,0 1250 kcmil
Continuation
589
Energy- and Power Cable / Medium Voltage Power Cables
590
Energy- and Power Cable / Medium Voltage Power Cables
Application
Installation primarily for power utility grids and in cable ducts, outdoors, underground and in water, and also on pallets for manufacturing plants,
switchgear and power stations. The resistant Al/PE-laminated sheathing acts as a cross water barrier. It inhibits the diffusion of water. In case of
sheathing damage, water impact is contained at the flaw. The cable can be severely mechanically stressed during installation and operation. The PE
sheathing is not flame-retardant to DIN EN 60332-1-2. The internal conductive layer between conductor and VPE insulation and the adherent external
conductive layer on the VPE insulation guarantees a design with high operational safety and no partial discharge.
Part no. No.cores x Operation Nominal Insulation Screen Sheath Outer Cop. Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. thickness app. mm weight app. kg / km
mm max. kV mm mm Nominal kg / km
value
mm
33054 1 x 35 rm / 16 12 6 / 10 3,4 16 2,5 28,0 518,0 860,0 2
33055 1 x 50 rm / 16 12 6 / 10 3,4 16 2,5 30,0 662,0 1000,0 1
33056 1 x 70 rm / 16 12 6 / 10 3,4 16 2,5 32,0 854,0 1350,0 2/0
33057 1 x 95 rm / 16 12 6 / 10 3,4 16 2,5 33,0 1094,0 1680,0 3/0
33058
33059
1 x 120
1 x 150
rm / 16
rm / 25
12
12
6 / 10
6 / 10
3,4
3,4
16
25
2,5
2,5
34,0
36,0
1334,0
1723,0
2070,0
2350,0
4/0
300 kcmil
Q
33060 1 x 185 rm / 25 12 6 / 10 3,4 25 2,5 38,0 2059,0 2710,0 350 kcmil
33061 1 x 240 rm / 25 12 6 / 10 3,4 25 2,5 40,0 2587,0 3260,0 500 kcmil
38049 1 x 300 rm / 25 12 6 / 10 3,4 25 2,5 42,0 3163,0 3850,0 600 kcmil
38050 1 x 400 rm / 35 12 6 / 10 3,4 35 2,5 46,0 4234,0 4740,0 750 kcmil
38051 1 x 500 rm / 35 12 6 / 10 3,4 35 2,5 49,0 5194,0 5800,0 1000 kcmil
38052 1 x 630 rm / 35 12 6 / 10 3,4 35 2,5 51,0 6442,0 7120,0 1250 kcmil
38053 1 x 35 rm / 16 24 12 / 20 5,5 16 2,5 33,0 518,0 1020,0 2
33066 1 x 50 rm / 16 24 12 / 20 5,5 16 2,5 35,0 662,0 1170,0 1
33067 1 x 70 rm / 16 24 12 / 20 5,5 16 2,5 36,0 854,0 1470,0 2/0
33083 1 x 95 rm / 16 24 12 / 20 5,5 16 2,5 38,0 1094,0 1860,0 3/0
33069 1 x 120 rm / 16 24 12 / 20 5,5 16 2,5 39,0 1334,0 2260,0 4/0
33070 1 x 150 rm / 25 24 12 / 20 5,5 25 2,5 41,0 1723,0 2550,0 300 kcmil
33071 1 x 185 rm / 25 24 12 / 20 5,5 25 2,5 43,0 2059,0 2920,0 350 kcmil
33072 1 x 240 rm / 25 24 12 / 20 5,5 25 2,5 45,0 2587,0 3490,0 500 kcmil
33073 1 x 300 rm / 25 24 12 / 20 5,5 25 2,5 47,0 3163,0 4090,0 600 kcmil
33074 1 x 400 rm / 35 24 12 / 20 5,5 35 2,5 50,0 4234,0 5010,0 750 kcmil
33075 1 x 500 rm / 35 24 12 / 20 5,5 35 2,5 54,0 5194,0 6090,0 1000 kcmil
38054 1 x 630 rm / 35 24 12 / 20 5,5 35 2,5 55,0 6442,0 7440,0 1250 kcmil
Continuation
591
Energy- and Power Cable / Medium Voltage Power Cables
592
Energy- and Power Cable / Medium Voltage Power Cables
Application
Suitable for installation mostly for power supply stations, in indoors and in cable ducts, outdoor with protected laying, underground and in water as
well as for installation on cable trays for industries, switch-boards and power stations. Due to the good laying characteristic, this can also be laid easily
in difficult line guideways.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.
Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight kg / km app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32440 1 x 50 rm / 16 12 6 / 10 3,4 2,5 24,0 - 29,0 182,0 145,0 780,0 1
32441 1 x 70 rm / 16 12 6 / 10 3,4 2,5 26,0 - 31,0 182,0 203,0 875,0 2/0
32442 1 x 95 rm / 16 12 6 / 10 3,4 2,5 26,0 - 32,0 182,0 276,0 990,0 3/0
32443 1 x 120 rm / 16 12 6 / 10 3,4 2,5 28,0 - 34,0 182,0 348,0 1110,0 4/0
32444
32445
1 x 150
1 x 150
rm / 16
rm / 25
12
12
6 / 10
6 / 10
3,4
3,4
2,5
2,5
29,0 - 35,0
29,0 - 35,0
182,0
283,0
435,0
435,0
1240,0
1310,0
300 kcmil
300 kcmil
Q
32446 1 x 185 rm / 16 12 6 / 10 3,4 2,5 31,0 - 37,0 182,0 537,0 1405,0 350 kcmil
32447 1 x 185 rm / 25 12 6 / 10 3,4 2,5 31,0 - 37,0 283,0 537,0 1460,0 350 kcmil
32448 1 x 240 rm / 16 12 6 / 10 3,4 2,5 33,0 - 39,0 182,0 696,0 1615,0 500 kcmil
32449 1 x 240 rm / 25 12 6 / 10 3,4 2,5 33,0 - 39,0 283,0 696,0 1660,0 500 kcmil
32450 1 x 300 rm / 25 12 6 / 10 3,4 2,5 36,0 - 41,0 283,0 870,0 1910,0 600 kcmil
32451 1 x 400 rm / 35 12 6 / 10 3,4 2,5 40,0 - 45,0 394,0 1160,0 2315,0 750 kcmil
32452 1 x 500 rm / 35 12 6 / 10 3,4 2,5 43,0 - 48,0 394,0 1450,0 2750,0 1000 kcmil
32453 1 x 50 rm / 16 24 12 / 20 5,5 2,5 28,0 - 33,0 182,0 145,0 950,0 1
32454 1 x 70 rm / 16 24 12 / 20 5,5 2,5 30,0 - 35,0 182,0 203,0 1110,0 2/0
32455 1 x 95 rm / 16 24 12 / 20 5,5 2,5 31,0 - 36,0 182,0 276,0 1220,0 3/0
32456 1 x 120 rm / 16 24 12 / 20 5,5 2,5 32,0 - 38,0 182,0 348,0 1310,0 4/0
32457 1 x 150 rm / 16 24 12 / 20 5,5 2,5 33,0 - 39,0 182,0 435,0 1460,0 300 kcmil
32458 1 x 150 rm / 25 24 12 / 20 5,5 2,5 33,0 - 39,0 283,0 435,0 1520,0 300 kcmil
32459 1 x 185 rm / 16 24 12 / 20 5,5 2,5 35,0 - 41,0 182,0 537,0 1660,0 350 kcmil
32460 1 x 185 rm / 25 24 12 / 20 5,5 2,5 35,0 - 41,0 283,0 537,0 1720,0 350 kcmil
32461 1 x 240 rm / 16 24 12 / 20 5,5 2,5 38,0 - 44,0 182,0 696,0 1860,0 500 kcmil
32462 1 x 240 rm / 25 24 12 / 20 5,5 2,5 38,0 - 44,0 283,0 696,0 1910,0 500 kcmil
32463 1 x 300 rm / 25 24 12 / 20 5,5 2,5 40,0 - 46,0 283,0 870,0 2220,0 600 kcmil
32464 1 x 400 rm / 35 24 12 / 20 5,5 2,5 43,0 - 49,0 394,0 1160,0 2620,0 750 kcmil
32465 1 x 500 rm / 35 24 12 / 20 5,5 2,5 46,0 - 52,0 394,0 1450,0 3030,0 1000 kcmil
32466 1 x 50 rm / 16 36 18 / 30 8 2,5 32,0 - 38,0 182,0 145,0 1260,0 1
32467 1 x 70 rm / 16 36 18 / 30 8 2,5 34,0 - 40,0 182,0 203,0 1360,0 2/0
Continuation
593
Energy- and Power Cable / Medium Voltage Power Cables
594
Energy- and Power Cable / Medium Voltage Power Cables
Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer sheath is resistant to high mechanical stress for laying the cables. This PE sheath is not flame retardant
acc. to DIN EN 60332-1-2.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.
Part no. No.cores x Operation Nominal Insulation Sheath Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness thickness min. - max. weight kg / km app. kg / km
mm max. kV mm Nominal mm kg / km
value
mm
32520 1 x 50 rm / 16 12 6 / 10 3,4 2,5 24,0 - 29,0 182,0 145,0 710,0 1
32521 1 x 70 rm / 16 12 6 / 10 3,4 2,5 26,0 - 31,0 182,0 203,0 790,0 2/0
32522 1 x 95 rm / 16 12 6 / 10 3,4 2,5 26,0 - 32,0 182,0 276,0 920,0 3/0
32523 1 x 120 rm / 16 12 6 / 10 3,4 2,5 28,0 - 34,0 182,0 348,0 990,0 4/0
32524
32525
1 x 150
1 x 150
rm / 16
rm / 25
12
12
6 / 10
6 / 10
3,4
3,4
2,5
2,5
29,0 - 35,0
29,0 - 35,0
182,0
283,0
435,0
435,0
1110,0
1220,0
300 kcmil
300 kcmil
Q
32526 1 x 185 rm / 16 12 6 / 10 3,4 2,5 31,0 - 37,0 182,0 537,0 1260,0 350 kcmil
32527 1 x 185 rm / 25 12 6 / 10 3,4 2,5 33,0 - 39,0 283,0 537,0 1370,0 350 kcmil
32528 1 x 240 rm / 16 12 6 / 10 3,4 2,5 33,0 - 39,0 182,0 696,0 1480,0 500 kcmil
32529 1 x 240 rm / 25 12 6 / 10 3,4 2,5 33,0 - 39,0 283,0 696,0 1530,0 500 kcmil
32530 1 x 300 rm / 25 12 6 / 10 3,4 2,5 36,0 - 41,0 283,0 870,0 1820,0 600 kcmil
32531 1 x 400 rm / 35 12 6 / 10 3,4 2,5 40,0 - 45,0 394,0 1160,0 2220,0 750 kcmil
32532 1 x 500 rm / 35 12 6 / 10 3,4 2,5 43,0 - 48,0 394,0 1450,0 2570,0 1000 kcmil
32533 1 x 50 rm / 16 24 12 / 20 5,5 2,5 28,0 - 33,0 182,0 145,0 890,0 1
32534 1 x 70 rm / 16 24 12 / 20 5,5 2,5 30,0 - 35,0 182,0 203,0 970,0 2/0
32535 1 x 95 rm / 16 24 12 / 20 5,5 2,5 31,0 - 36,0 182,0 276,0 1120,0 3/0
32536 1 x 120 rm / 16 24 12 / 20 5,5 2,5 32,0 - 38,0 182,0 348,0 1210,0 4/0
32537 1 x 150 rm / 16 24 12 / 20 5,5 2,5 33,0 - 39,0 182,0 435,0 1370,0 300 kcmil
32538 1 x 150 rm / 25 24 12 / 20 5,5 2,5 33,0 - 39,0 283,0 435,0 1420,0 300 kcmil
32539 1 x 185 rm / 16 24 12 / 20 5,5 2,5 35,0 - 41,0 182,0 537,0 1530,0 350 kcmil
32540 1 x 185 rm / 25 24 12 / 20 5,5 2,5 35,0 - 41,0 283,0 537,0 1570,0 350 kcmil
32541 1 x 240 rm / 16 24 12 / 20 5,5 2,5 38,0 - 44,0 182,0 696,0 1720,0 500 kcmil
32542 1 x 240 rm / 25 24 12 / 20 5,5 2,5 38,0 - 44,0 283,0 696,0 1830,0 500 kcmil
32543 1 x 300 rm / 25 24 12 / 20 5,5 2,5 40,0 - 46,0 283,0 870,0 2070,0 600 kcmil
32544 1 x 400 rm / 35 24 12 / 20 5,5 2,5 43,0 - 49,0 394,0 1160,0 2460,0 750 kcmil
32545 1 x 500 rm / 35 24 12 / 20 5,5 2,5 46,0 - 52,0 394,0 1450,0 2890,0 1000 kcmil
33078 1 x 630 rm / 35 24 12 / 20 5,5 2,5 47,0 - 53,0 394,0 1827,0 3370,0 1250 kcmil
32546 1 x 50 rm / 16 36 18 / 30 8 2,5 32,0 - 38,0 182,0 145,0 1120,0 1
Continuation
595
Energy- and Power Cable / Medium Voltage Power Cables
596
Energy- and Power Cable / Medium Voltage Power Cables
Application
Suitable for indoor installation and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries,
switch-boards and power stations. The PE-outer sheath is resistant to high mechanical stress for laying the cables. This PE sheath is not flame retardant
acc. to DIN EN 60332-1-2.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.
Part no. No.cores x Operation Nominal Insulation Screen Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. app. mm weight kg / km app. kg / km
mm max. kV mm mm kg / km
32600 1 x 35 rm / 16 12 6 / 10 3,4 16 26,0 182,0 102,0 780,0 2
32601 1 x 50 rm / 16 12 6 / 10 3,4 16 28,0 182,0 145,0 850,0 1
32602 1 x 70 rm / 16 12 6 / 10 3,4 16 30,0 182,0 203,0 980,0 2/0
32603 1 x 95 rm / 16 12 6 / 10 3,4 16 31,0 182,0 276,0 1080,0 3/0
32604 1 x 120 rm / 16 12 6 / 10 3,4 16 32,0 182,0 348,0 1150,0 4/0
Q
32605 1 x 150 rm / 25 12 6 / 10 3,4 25 34,0 283,0 435,0 1280,0 300 kcmil
32606 1 x 185 rm / 25 12 6 / 10 3,4 25 36,0 283,0 537,0 1420,0 350 kcmil
32607 1 x 240 rm / 25 12 6 / 10 3,4 25 38,0 283,0 696,0 1630,0 500 kcmil
32608 1 x 300 rm / 25 12 6 / 10 3,4 25 40,0 283,0 870,0 1950,0 600 kcmil
32609 1 x 400 rm / 35 12 6 / 10 3,4 35 44,0 394,0 1160,0 2350,0 750 kcmil
32610 1 x 500 rm / 35 12 6 / 10 3,4 35 47,0 394,0 1450,0 2780,0 1000 kcmil
32611 1 x 50 rm / 16 24 12 / 20 5,5 16 33,0 182,0 145,0 920,0 1
32612 1 x 70 rm / 16 24 12 / 20 5,5 16 34,0 182,0 203,0 1030,0 2/0
32613 1 x 95 rm / 16 24 12 / 20 5,5 16 36,0 182,0 276,0 1140,0 3/0
32614 1 x 120 rm / 16 24 12 / 20 5,5 16 37,0 182,0 348,0 1250,0 4/0
32615 1 x 150 rm / 25 24 12 / 20 5,5 25 39,0 283,0 435,0 1320,0 300 kcmil
32616 1 x 185 rm / 25 24 12 / 20 5,5 25 41,0 283,0 537,0 1570,0 350 kcmil
32617 1 x 240 rm / 25 24 12 / 20 5,5 25 43,0 283,0 696,0 1780,0 500 kcmil
32618 1 x 300 rm / 25 24 12 / 20 5,5 25 45,0 283,0 870,0 2100,0 600 kcmil
32619 1 x 400 rm / 35 24 12 / 20 5,5 35 48,0 394,0 1160,0 2480,0 750 kcmil
32620 1 x 500 rm / 35 24 12 / 20 5,5 35 50,0 394,0 1450,0 2900,0 1000 kcmil
33090 1 x 630 rm / 35 24 12 / 20 5,5 35 52,0 394,0 1827,0 3380,0 1250 kcmil
33091 1 x 800 rm / 35 24 12 / 20 5,5 35 57,0 394,0 2320,0 4400,0 1500 kcmil
33097 1 x 1000 rm / 35 24 12 / 20 5,5 35 62,0 394,0 2900,0 4780,0 2000 kcmil
Continuation
597
Energy- and Power Cable / Medium Voltage Power Cables
598
Energy- and Power Cable / Medium Voltage Power Cables
Application
Installation primarily for power utility grids and in cable ducts, outdoors, underground and in water, and also on pallets for manufacturing plants,
switchgear and power stations. The resistant Al/PE-laminated sheathing acts as a cross water barrier. It inhibits the diffusion of water. In case of
sheathing damage, water impact is contained at the flaw. The cable can be severely mechanically stressed during installation and operation. The PE
sheathing is not flame-retardant to DIN EN 60332-1-2. The internal conductive layer between conductor and VPE insulation and the adherent external
conductive layer on the VPE insulation guarantees a design with high operational safety and no partial discharge.
Part no. No.cores x Operation Nominal Insulation Screen Outer Cop. Alu weight Weight AWG-No.
cross-sec. voltage voltage thickness cross-sec. app. mm weight kg / km app. kg / km
mm max. kV mm mm kg / km
38062 1 x 50 rm / 16 12 6 / 10 3,4 16 30,0 182,0 145,0 710,0 1
38063 1 x 70 rm / 16 12 6 / 10 3,4 16 32,0 182,0 203,0 890,0 2/0
38064 1 x 95 rm / 16 12 6 / 10 3,4 16 33,0 182,0 276,0 1100,0 3/0
38065 1 x 120 rm / 16 12 6 / 10 3,4 16 34,0 182,0 348,0 1330,0 4/0
38066 1 x 150 rm / 25 12 6 / 10 3,4 25 36,0 283,0 435,0 1450,0 300 kcmil
Q
38067 1 x 185 rm / 25 12 6 / 10 3,4 25 38,0 283,0 537,0 1580,0 350 kcmil
38068 1 x 240 rm / 25 12 6 / 10 3,4 25 40,0 283,0 696,0 1780,0 500 kcmil
38069 1 x 300 rm / 25 12 6 / 10 3,4 25 42,0 283,0 870,0 1990,0 600 kcmil
38070 1 x 400 rm / 35 12 6 / 10 3,4 35 46,0 394,0 1160,0 2320,0 750 kcmil
38071 1 x 500 rm / 35 12 6 / 10 3,4 35 49,0 394,0 1450,0 2690,0 1000 kcmil
38072 1 x 630 rm / 35 12 6 / 10 3,4 35 51,0 394,0 1827,0 3160,0 1250 kcmil
38073 1 x 50 rm / 16 24 12 / 20 5,5 16 35,0 182,0 145,0 870,0 1
38074 1 x 70 rm / 16 12 12 / 20 5,5 16 36,0 182,0 203,0 1060,0 2/0
38075 1 x 95 rm / 16 24 12 / 20 5,5 16 38,0 182,0 276,0 1280,0 3/0
38076 1 x 120 rm / 16 24 12 / 20 5,5 16 39,0 182,0 348,0 1520,0 4/0
33089 1 x 150 rm / 25 24 12 / 20 5,5 25 41,0 283,0 435,0 1650,0 300 kcmil
38077 1 x 185 rm / 25 24 12 / 20 5,5 25 43,0 283,0 537,0 1800,0 350 kcmil
38078 1 x 240 rm / 25 24 12 / 20 5,5 25 45,0 283,0 696,0 2000,0 500 kcmil
38079 1 x 300 rm / 25 24 12 / 20 5,5 25 47,0 283,0 870,0 2230,0 600 kcmil
38080 1 x 400 rm / 35 24 12 / 20 5,5 35 50,0 394,0 1160,0 2580,0 750 kcmil
38081 1 x 500 rm / 35 24 12 / 20 5,5 35 54,0 394,0 1450,0 2980,0 1000 kcmil
38082 1 x 630 rm / 35 24 6 / 10 5,5 35 55,0 394,0 1827,0 3480,0 1250 kcmil
Continuation
599
Energy- and Power Cable / Medium Voltage Power Cables
600
Energy- and Power Cable / Medium Voltage Power Cables
601
Energy- and Power Cable / Medium Voltage Power Cables
Application
Suitable for installation in indoors and in cable ducts, outdoors with protected laying, as well as for laying on racks for industrial and switching systems
and power plants. Limited use when buried in the earth if the PVC outer sheath could be damaged by high mechanical stress.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.
Part no. No.cores x Insulation Screen Sheath Outer Cop. Weight AWG-No.
cross-sec. thickness cross-sec. thickness app. mm weight app. kg / km
mm mm mm Nominal value kg / km
mm
34339 3 x 25 rm / 16 3,4 16 2,5 43,0 1046,0 2850,0 4
34340 3 x 35 rm / 16 3,4 16 2,5 48,0 1210,0 3300,0 2
34341 3 x 50 rm / 16 3,4 16 2,5 50,0 1671,0 3750,0 1
34342 3 x 70 rm / 16 3,4 16 2,6 54,0 2250,0 4650,0 2/0
34343 3 x 95 rm / 16 3,4 16 2,8 58,0 2995,0 5700,0 3/0
34344 3 x 120 rm / 16 3,4 16 2,9 61,0 3715,0 6700,0 4/0
34345 3 x 150 rm / 25 3,4 25 3,0 65,0 4638,0 7900,0 300 kcmil
34346 3 x 185 rm / 25 3,4 25 3,1 68,0 5645,0 9200,0 350 kcmil
34347 3 x 240 rm / 25 3,4 25 3,3 74,0 7274,0 11450,0 500 kcmil
34348 3 x 300 rm / 25 3,4 25 3,3 79,0 9160,0 14450,0 600 kcmil
602
Energy- and Power Cable / Medium Voltage Power Cables
Note
rm = round conductor, multi-wire
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
Suitable for installation in indoors and in cable ducts, outdoors as well as for laying on racks for industrial and switching systems and power plants.
Limited use when buried in the earth if the outer sheath could be damaged by high mechanical stress.
The inner conducting layer between the conductor and the XLPE insulation and the firmly bonded outer conducting layer on the XLPE insulation assures
a construction free of partial discharges with high operational reliability.
Part no. No.cores x Insulation Screen Sheath Outer Cop. Weight AWG-No.
cross-sec.
mm
thickness
mm
cross-sec.
mm
thickness
Nominal value
app. mm weight
kg / km
app. kg / km
Q
mm
38041 3 x 50 rm / 16 3,4 16 2,5 50,0 1670,0 3800,0 1
38042 3 x 70 rm / 16 3,4 16 2,5 54,0 2250,0 4650,0 2/0
38043 3 x 95 rm / 16 3,4 16 2,5 58,0 2995,0 5700,0 3/0
38044 3 x 120 rm / 16 3,4 16 2,5 61,0 3715,0 6800,0 4/0
38045 3 x 150 rm / 25 3,4 25 2,5 65,0 4635,0 7900,0 300 kcmil
38046 3 x 185 rm / 25 3,4 25 2,5 68,0 5645,0 9350,0 350 kcmil
38047 3 x 240 rm / 25 3,4 25 2,5 74,0 7274,0 11450,0 500 kcmil
603
604
DATA, NETWORK & BUS TECHNOLOGY
605
606
FIBER OPTIC CABLES HELUCOM
HELUCOM pact fiber optic universal cable A/IDQ(ZN)BH OM3 + OM4 614
Fiber optic outdoor cable HELUCOM pact A-DQ(ZN)B2Y fiber combination 624
638
R
Fiber optic cable flexible AT-V(ZN)YY 639
607
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres app. mm tensile bending app. MJ / m transverse kg / km
force N radius pressure
mm N / cm
I-VH 1 Multimode G50/125 OM2 2,6 300 40 0,17 10 8,7 80783
I-VH 1 Multimode G62.5/125 OM1 2,6 300 40 0,17 10 8,7 80782
I-VH 1 Single-mode E9/125 ITU-T G.652 2,6 300 40 0,17 10 8,7 80784
I-VH 2 Multimode G50/125 OM2 2,6 x 5,6 400 40 0,24 10 17,5 80316
I-VH 2 Multimode G50/125 OM3 2,6 x 5,6 400 40 0,24 10 17,5 804256
I-VH 2 Multimode G62.5/125 OM1 2,6 x 5,6 400 40 0,24 10 17,5 80699
I-VH 2 Single-mode E9/125 ITU-T G.652 2,6 x 5,6 400 40 0,24 10 17,5 80785
I-V11Y 2 Multimode G50/125 OM2 2,6 x 5,6 400 40 2,80 20 14,0 82408
I-V11Y 2 Multimode G62.5/125 OM1 2,6 x 5,6 400 40 2,80 20 14,0 82410
I-V11Y 2 Single-mode E9/125 ITU-T G.652 2,6 x 5,6 400 40 2,80 20 14,0 82411
I-VHH 2 Multimode G50/125 OM2 3,6 x 6,2 600 50 0,57 20 20,0 80789
I-VHH 2 Multimode G50/125 OM3 3,6 x 6,2 600 50 0,57 20 20,0 804254
I-VHH 2 Multimode G62.5/125 OM1 3,6 x 6,2 600 50 0,57 20 20,0 80790
I-VHH 2 Single-mode E9/125 ITU-T G.652 3,6 x 6,2 600 50 0,57 20 20,0 80791
I-V11Y11Y 2 Multimode G50/125 OM2 3,6 x 6,2 600 60 4,20 20 16,0 82409
I-V11Y11Y 2 Multimode G62.5/125 OM1 3,6 x 6,2 600 60 4,20 20 16,0 81900
I-V11Y11Y 2 Single-mode E9/125 ITU-T G.652 3,6 x 6,2 600 60 4,20 20 16,0 82412
Application
These HELUCOM one-fibre and two-fibre (duplex) cables are used for fixed indoor installation, such as in cable ducts. These cables are also used as
ready-made cables (pigtails) that are spliced to fixed cables or as connection cables (jumper cable) as well as for switch frames. The small diameter
and the high flexibility make these cables ideal for the application in switch frames as well as for the connection of terminals.
608
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
I-V(ZN)HH 2 Multimode G50/125 OM2 1 7,1 1000 270,0 1,00 150 40,0 80743
I-V(ZN)HH 2 Multimode G62.5/125 OM1 1 7,1 1000 270,0 1,00 150 40,0 80799
I-V(ZN)HH 2 Single-mode E9/125 ITU-T G.652 1 7,1 1000 270,0 1,00 150 40,0 80813
I-V(ZN)HH 4 Multimode G50/125 OM2 1 7,1 1000 270,0 1,00 150 45,0 80753
I-V(ZN)HH 4 Multimode G62.5/125 OM1 1 7,1 1000 270,0 1,00 150 45,0 80800
I-V(ZN)HH 4 Single-mode E9/125 ITU-T G.652 1 7,1 1000 270,0 1,00 150 45,0 80814
I-V(ZN)HH 6 Multimode G50/125 OM2 1 8,4 1350 270,0 1,25 150 70,0 80754
I-V(ZN)HH 6 Multimode G62.5/125 OM1 1 8,4 1350 270,0 1,25 150 70,0 80769
I-V(ZN)HH 6 Single-mode E9/125 ITU-T G.652 1 8,4 1350 270,0 1,25 150 70,0 80815
I-V(ZN)HH 8 Multimode G50/125 OM2 1 9,3 1500 270,0 1,50 150 100,0 80688
I-V(ZN)HH 8 Multimode G62.5/125 OM1 1 9,3 1500 270,0 1,50 150 100,0 80801
I-V(ZN)HH 8 Single-mode E9/125 ITU-T G.652 1 9,3 1500 270,0 1,50 150 100,0 80816
I-V(ZN)HH 12 Multimode G50/125 OM2 1 9,6 2350 270,0 1,85 150 165,0 80795
I-V(ZN)HH 12 Multimode G62.5/125 OM1 1 9,6 2350 270,0 1,85 150 165,0 80803
I-V(ZN)HH 12 Single-mode E9/125 ITU-T G.652 1 9,6 2350 270,0 1,85 150 165,0 80818
I-V(ZN)HH 16 Multimode G50/125 OM2 1 15,0 2400 270,0 2,40 150 170,0 80796
I-V(ZN)HH 16 Multimode G62.5/125 OM1 1 15,0 2400 270,0 2,40 150 170,0 80804
I-V(ZN)HH 16 Single-mode E9/125 ITU-T G.652 1 15,0 2400 270,0 2,40 150 170,0 80819
I-V(ZN)HH 24 Multimode G50/125 OM2 1 17,5 2400 330,0 3,20 150 220,0 80798
I-V(ZN)HH 24 Multimode G62.5/125 OM1 1 17,5 2400 330,0 3,20 150 220,0 80806
I-V(ZN)HH 24 Single-mode E9/125 ITU-T G.652 1 17,5 2400 320,0 3,20 150 220,0 80821
Application
HELUCOM breakout cables are designed to replace splicing on-site. They are mainly used in indoor applications for small and medium transmission
lines. The fibre-optic connectors are be mounted directly to the individual cables. Therefore no splicing and no splice boxes are necessary. Pre-assembled
cables only need to be laid on site and are immediately functional.
609
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
I-V(ZN)H 2 Multimode G50/125 OM2 1 4,0 400 60,0 0,24 40 15,0 80435
I-V(ZN)H 2 Multimode G62.5/125 OM1 1 4,0 400 60,0 0,24 40 15,0 80434
I-V(ZN)H 2 Single-mode E9/125 ITU-T G.652 1 4,0 400 60,0 0,24 40 15,0 80433
I-V(ZN)H 4 Multimode G50/125 OM2 1 4,8 400 70,0 0,31 40 19,0 80432
I-V(ZN)H 4 Multimode G62.5/125 OM1 1 4,8 400 70,0 0,31 40 19,0 80431
I-V(ZN)H 4 Single-mode E9/125 ITU-T G.652 1 4,8 400 70,0 0,31 40 19,0 80430
I-V(ZN)H 6 Multimode G50/125 OM2 1 5,3 400 80,0 0,35 40 23,0 80429
I-V(ZN)H 6 Multimode G62.5/125 OM1 1 5,3 400 80,0 0,35 40 23,0 80428
I-V(ZN)H 6 Single-mode E9/125 ITU-T G.652 1 5,3 400 80,0 0,35 40 23,0 80427
I-V(ZN)H 8 Multimode G50/125 OM2 1 5,3 500 80,0 0,40 40 25,0 80426
I-V(ZN)H 8 Multimode G62.5/125 OM1 1 5,3 500 80,0 0,40 40 25,0 80425
I-V(ZN)H 8 Single-mode E9/125 ITU-T G.652 1 5,3 500 80,0 0,40 40 25,0 80424
I-V(ZN)H 10 Multimode G50/125 OM2 1 6,0 600 90,0 0,53 40 32,0 80423
I-V(ZN)H 10 Multimode G62.5/125 OM1 1 6,0 600 90,0 0,53 40 32,0 80422
I-V(ZN)H 10 Single-mode E9/125 ITU-T G.652 1 6,0 600 90,0 0,53 40 32,0 80421
I-V(ZN)H 12 Multimode G50/125 OM2 1 7,0 800 110,0 0,61 40 40,0 80420
I-V(ZN)H 12 Multimode G62.5/125 OM1 1 7,0 800 110,0 0,61 40 40,0 80419
I-V(ZN)H 12 Single-mode E9/125 ITU-T G.652 1 7,0 800 110,0 0,61 40 40,0 80418
Application
These HELUCOM fibre-optic cables are used for the data network cabling in indoor applications. A big advantage of this cable type is its space-saving
construction. Similar to the breakout cable, the connector is directly mounted at the tight buffer.
610
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
I-D(ZN)H 4 Multimode G50/125 OM2 4 8,0 1200 120,0 1,50 150 65,0 80631
I-D(ZN)H 4 Multimode G62.5/125 OM1 4 8,0 1200 120,0 1,50 150 65,0 80882
I-D(ZN)H 4 Single-mode E9/125 ITU-T G.652 4 8,0 1200 120,0 1,50 150 65,0 80896
I-D(ZN)H 6 Multimode G50/125 OM2 6 8,0 1200 120,0 1,50 150 65,0 80868
I-D(ZN)H 6 Multimode G62.5/125 OM1 6 8,0 1200 120,0 1,50 150 65,0 80883
I-D(ZN)H 6 Single-mode E9/125 ITU-T G.652 6 8,0 1200 120,0 1,50 150 65,0 80897
I-D(ZN)H 8 Multimode G50/125 OM2 8 8,0 1200 120,0 1,50 150 65,0 80869
I-D(ZN)H 8 Multimode G62.5/125 OM1 8 8,0 1200 120,0 1,50 150 65,0 80884
I-D(ZN)H 8 Single-mode E9/125 ITU-T G.652 8 8,0 1200 120,0 1,50 150 65,0 80898
I-D(ZN)H 10 Multimode G50/125 OM2 10 8,0 1200 120,0 1,50 150 65,0 80793
I-D(ZN)H 10 Multimode G62.5/125 OM1 10 8,0 1200 120,0 1,50 150 65,0 80885
I-D(ZN)H 10 Single-mode E9/125 ITU-T G.652 10 8,0 1200 120,0 1,50 150 65,0 80899
I-D(ZN)H 12 Multimode G50/125 OM2 12 8,0 1200 120,0 1,50 150 65,0 80045
I-D(ZN)H 12 Multimode G62.5/125 OM1 12 8,0 1200 120,0 1,50 150 65,0 80879
I-D(ZN)H 12 Single-mode E9/125 ITU-T G.652 12 8,0 1200 120,0 1,50 150 65,0 80880
I-D(ZN)H 16 Multimode G50/125 OM2 16 8,0 1200 120,0 1,50 150 135,0 80870
I-D(ZN)H 16 Multimode G62.5/125 OM1 16 8,0 1200 120,0 1,50 150 135,0 80886
I-D(ZN)H 16 Single-mode E9/125 ITU-T G.652 16 8,0 1200 120,0 1,50 150 135,0 80900
I-D(ZN)H 24 Multimode G50/125 OM2 12 12,5 3000 190,0 2,20 200 150,0 80872
I-D(ZN)H 24 Multimode G50/125 OM2 24 9,0 1600 140,0 1,50 150 135,0 80871
I-D(ZN)H 24 Multimode G62.5/125 OM1 12 12,5 3000 190,0 2,20 200 150,0 80888
I-D(ZN)H 24 Multimode G62.5/125 OM1 24 9,0 1600 140,0 1,50 150 135,0 81246
I-D(ZN)H 24 Single-mode E9/125 ITU-T G.652 12 12,5 3000 190,0 2,20 200 150,0 80902
I-D(ZN)H 24 Single-mode E9/125 ITU-T G.652 24 9,0 1600 140,0 1,50 150 135,0 80901
I-D(ZN)H 36 Multimode G50/125 OM2 12 13,5 3000 200,0 2,20 200 160,0 80875
I-D(ZN)H 36 Multimode G62.5/125 OM1 12 13,5 3000 200,0 2,20 200 160,0 80891
I-D(ZN)H 36 Single-mode E9/125 ITU-T G.652 12 13,5 3000 200,0 2,20 200 160,0 80905
I-D(ZN)H 48 Multimode G50/125 OM2 12 13,5 3000 200,0 2,20 200 160,0 80877
I-D(ZN)H 48 Multimode G62.5/125 OM1 12 13,5 3000 200,0 2,20 200 160,0 80893
I-D(ZN)H 48 Single-mode E9/125 ITU-T G.652 12 13,5 3000 200,0 2,20 200 160,0 80907
I-D(ZN)H 60 Multimode G50/125 OM2 12 13,5 3000 200,0 2,20 200 170,0 80878
I-D(ZN)H 60 Multimode G62.5/125 OM1 12 13,5 3000 200,0 2,20 200 170,0 80894
I-D(ZN)H 60 Single-mode E9/125 ITU-T G.652 12 13,5 3000 200,0 2,20 200 170,0 80908 R
Dimensions and specifications may be changed without prior notice.
Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor cabling of
buildings and facilities. The halogen-free version is especially suitable for the application in skyscrapers, hospitals and stores as well as in facilities with
high concentration of capital goods, such as power plants, computing centers, and at locations with high security requirements, such as underground
and control stations.
611
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-VQ(ZN)BH 4 Multimode G50/125 OM2 1 6,1 2000 90,0 0,35 40 40,0 82804
A/I-VQ(ZN)BH 4 Multimode G62.5/125 OM1 1 6,1 2000 90,0 0,35 40 40,0 82809
A/I-VQ(ZN)BH 4 Single-mode E9/125 ITU-T G.652 1 6,1 2000 90,0 0,35 40 40,0 82814
A/I-VQ(ZN)BH 6 Multimode G50/125 OM2 1 6,6 2000 100,0 0,41 40 47,0 82805
A/I-VQ(ZN)BH 6 Multimode G62.5/125 OM1 1 6,6 2000 100,0 0,41 40 47,0 82810
A/I-VQ(ZN)BH 6 Single-mode E9/125 ITU-T G.652 1 6,6 2000 100,0 0,41 40 47,0 82815
A/I-VQ(ZN)BH 8 Multimode G50/125 OM2 1 6,6 2000 100,0 0,43 40 51,0 82806
A/I-VQ(ZN)BH 8 Multimode G62.5/125 OM1 1 6,6 2000 100,0 0,43 40 51,0 82811
A/I-VQ(ZN)BH 8 Single-mode E9/125 ITU-T G.652 1 6,6 2000 100,0 0,43 40 51,0 82816
A/I-VQ(ZN)BH 10 Multimode G50/125 OM2 1 8,0 2000 120,0 0,61 40 65,0 82807
A/I-VQ(ZN)BH 10 Multimode G62.5/125 OM1 1 8,0 2000 120,0 0,61 40 65,0 82812
A/I-VQ(ZN)BH 10 Single-mode E9/125 ITU-T G.652 1 8,0 2000 120,0 0,61 40 65,0 82817
A/I-VQ(ZN)BH 12 Multimode G50/125 OM2 1 8,3 3000 125,0 0,71 40 70,0 82808
A/I-VQ(ZN)BH 12 Multimode G62.5/125 OM1 1 8,3 3000 125,0 0,71 40 70,0 82813
A/I-VQ(ZN)BH 12 Single-mode E9/125 ITU-T G.652 1 8,3 3000 125,0 0,71 40 70,0 82818
Application
These HELUCOM fibre-optic cables are used for the data network cabling in indoor and outdoor applications. With their black UV-resistant outer
sheath and the non-metallic rodent protection, they are perfectly suited for outdoor use. A big advantage of this cable type is its space-saving
construction. Similar to the breakout cable, the connector is directly mounted at the tight buffer.
612
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 4 Multimode G50/125 OM2 4 7,5 1500 150,0 1,10 200 55,0 82792
A/I-DQ(ZN)BH 4 Multimode G62.5/125 OM1 4 7,5 1500 150,0 1,10 200 55,0 82796
A/I-DQ(ZN)BH 4 Single-mode E9/125 ITU-T G.652 4 7,5 1500 150,0 1,10 200 55,0 82800
A/I-DQ(ZN)BH 6 Multimode G50/125 OM2 6 7,5 1500 150,0 1,10 200 55,0 82793
A/I-DQ(ZN)BH 6 Multimode G62.5/125 OM1 6 7,5 1500 150,0 1,10 200 55,0 82797
A/I-DQ(ZN)BH 6 Single-mode E9/125 ITU-T G.652 6 7,5 1500 150,0 1,10 200 55,0 82801
A/I-DQ(ZN)BH 8 Multimode G50/125 OM2 8 7,5 1500 150,0 1,10 200 55,0 82794
A/I-DQ(ZN)BH 8 Multimode G62.5/125 OM1 8 7,5 1500 150,0 1,10 200 55,0 82798
A/I-DQ(ZN)BH 8 Single-mode E9/125 ITU-T G.652 8 7,5 1500 150,0 1,10 200 55,0 82802
A/I-DQ(ZN)BH 12 Multimode G50/125 OM2 12 7,5 1500 150,0 1,10 200 55,0 82795
A/I-DQ(ZN)BH 12 Multimode G62.5/125 OM1 12 7,5 1500 150,0 1,10 200 55,0 82799
A/I-DQ(ZN)BH 12 Single-mode E9/125 ITU-T G.652 12 7,5 1500 150,0 1,10 200 55,0 82803
A/I-DQ(ZN)BH 24 Multimode G50/125 OM2 24 8,5 1500 170,0 1,40 200 75,0 802143
A/I-DQ(ZN)BH 24 Multimode G62.5/125 OM1 24 8,5 1500 170,0 1,40 200 75,0 802144
A/I-DQ(ZN)BH 24 Single-mode E9/125 ITU-T G.652 24 8,5 1500 170,0 1,40 200 75,0 802145
Application
These HELUCOM pact fibre-optic cables have a small but robust construction. They are suitable for indoor and outdoor cabling of buildings and
facilities when space is an important argument. They are used in particular if the installation is to be done in one piece from the inside to the outside
without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are perfectly suited for
outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.
613
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 4 Multimode G50/125 OM3 4 7,5 1500 150,0 1,10 200 55,0 802247
A/I-DQ(ZN)BH 6 Multimode G50/125 OM3 6 7,5 1500 150,0 1,10 200 55,0 802277
A/I-DQ(ZN)BH 8 Multimode G50/125 OM3 8 7,5 1500 150,0 1,10 200 55,0 802278
A/I-DQ(ZN)BH 12 Multimode G50/125 OM3 12 7,5 1500 150,0 1,10 200 55,0 802248
A/I-DQ(ZN)BH 24 Multimode G50/125 OM3 24 8,5 1500 170,0 1,40 200 75,0 802249
A/I-DQ(ZN)BH 12 Multimode G50/125 OM4 12 7,5 1500 150,0 1,10 200 55,0 804705
A/I-DQ(ZN)BH 24 Multimode G50/125 OM4 24 8,5 1500 170,0 1,40 200 75,0 804706
Application
These HELUCOM pact fibre-optic cables have a small but robust construction. They are suitable for indoor and outdoor cabling of buildings and
facilities when space is an important argument. They are used in particular if the installation is to be done in one piece from the inside to the outside
without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are perfectly suited for
outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.
614
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 4 Multimode G50/125 OM2 4 10,0 2500 150,0 1,50 300 75,0 80270
A/I-DQ(ZN)BH 4 Multimode G62.5/125 OM1 4 10,0 2500 150,0 1,50 300 75,0 80276
A/I-DQ(ZN)BH 4 Single-mode E9/125 ITU-T G.652 4 10,0 2500 150,0 1,50 300 75,0 80264
A/I-DQ(ZN)BH 6 Multimode G50/125 OM2 6 10,0 2500 150,0 1,50 300 75,0 80271
A/I-DQ(ZN)BH 6 Multimode G62.5/125 OM1 6 10,0 2500 150,0 1,50 300 75,0 80265
A/I-DQ(ZN)BH 6 Single-mode E9/125 ITU-T G.652 6 10,0 2500 150,0 1,50 300 75,0 80272
A/I-DQ(ZN)BH 8 Multimode G50/125 OM2 8 10,0 2500 150,0 1,50 300 75,0 80273
A/I-DQ(ZN)BH 8 Multimode G62.5/125 OM1 8 10,0 2500 150,0 1,50 300 75,0 80274
A/I-DQ(ZN)BH 8 Single-mode E9/125 ITU-T G.652 8 10,0 2500 150,0 1,50 300 75,0 80275
A/I-DQ(ZN)BH 12 Multimode G50/125 OM2 12 10,0 2500 150,0 1,50 300 75,0 80681
A/I-DQ(ZN)BH 12 Multimode G62.5/125 OM1 12 10,0 2500 150,0 1,50 300 75,0 80278
A/I-DQ(ZN)BH 12 Single-mode E9/125 ITU-T G.652 12 10,0 2500 150,0 1,50 300 75,0 80279
A/I-DQ(ZN)BH 16 Multimode G50/125 OM2 16 10,0 2500 150,0 1,50 300 85,0 80280
A/I-DQ(ZN)BH 16 Multimode G62.5/125 OM1 16 10,0 2500 150,0 1,50 300 85,0 80281
A/I-DQ(ZN)BH 16 Single-mode E9/125 ITU-T G.652 16 10,0 2500 150,0 1,50 300 85,0 80851
A/I-DQ(ZN)BH 24 Multimode G50/125 OM2 24 10,0 2500 150,0 1,50 300 85,0 80725
A/I-DQ(ZN)BH 24 Multimode G62.5/125 OM1 24 10,0 2500 150,0 1,50 300 85,0 82431
Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor and outdoor
cabling of buildings and facilities. They are used in particular if the installation is to be done in one piece from the inside to the outside without additional
use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are perfectly suited for outdoor use. The
halogen-free outer sheath makes installation inhouse possible without any problems.
615
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 24 Multimode G50/125 OM2 12 11,0 2700 165,0 2,00 600 90,0 81495
A/I-DQ(ZN)BH 24 Multimode G62.5/125 OM1 12 11,0 2700 165,0 2,00 600 90,0 802263
A/I-DQ(ZN)BH 24 Single-mode E9/125 ITU-T G.652 12 11,0 2700 165,0 2,00 600 90,0 80846
A/I-DQ(ZN)BH 48 Multimode G50/125 OM2 12 11,0 2700 165,0 2,00 600 90,0 802261
A/I-DQ(ZN)BH 48 Multimode G62.5/125 OM1 12 11,0 2700 165,0 2,00 600 90,0 802264
A/I-DQ(ZN)BH 48 Single-mode E9/125 ITU-T G.652 12 11,0 2700 165,0 2,00 600 90,0 802266
A/I-DQ(ZN)BH 48 Single-mode E9/125 ITU-T G.652 12 11,0 2700 165,0 2,00 600 90,0 802281
A/I-DQ(ZN)BH 60 Multimode G50/125 OM2 12 11,0 2700 165,0 2,00 600 90,0 802262
A/I-DQ(ZN)BH 60 Multimode G62.5/125 OM1 12 11,0 2700 165,0 2,00 600 90,0 802265
A/I-DQ(ZN)BH 60 Single-mode E9/125 ITU-T G.652 12 11,0 2700 165,0 2,00 600 90,0 802267
A/I-DQ(ZN)BH 72 Multimode G50/125 OM2 12 11,5 2700 175,0 2,10 600 100,0 802268
A/I-DQ(ZN)BH 72 Multimode G62.5/125 OM1 12 11,5 2700 175,0 2,10 600 100,0 802271
A/I-DQ(ZN)BH 72 Single-mode E9/125 ITU-T G.652 12 11,5 2700 175,0 2,10 600 100,0 802274
A/I-DQ(ZN)BH 84 Multimode G50/125 OM2 12 12,5 3000 190,0 2,40 600 130,0 802269
A/I-DQ(ZN)BH 84 Multimode G62.5/125 OM1 12 12,5 3000 190,0 2,40 600 130,0 802272
A/I-DQ(ZN)BH 84 Single-mode E9/125 ITU-T G.652 12 12,5 3000 190,0 2,40 600 130,0 802275
A/I-DQ(ZN)BH 96 Multimode G50/125 OM2 12 12,5 3000 190,0 2,80 600 130,0 802270
A/I-DQ(ZN)BH 96 Multimode G62.5/125 OM1 12 12,5 3000 190,0 2,80 600 130,0 802273
A/I-DQ(ZN)BH 96 Single-mode E9/125 ITU-T G.652 12 12,5 3000 190,0 2,80 600 130,0 802276
Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for indoor and outdoor
cabling of buildings and facilities. They are used in particular if the installation is to be done in one piece from the inside to the outside without additional
use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are perfectly suited for outdoor use. The
halogen-free outer sheath makes installation inhouse possible without any problems.
616
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 4 Multimode G50/125 OM2 4 7,8 1000 80,0 1,08 200 102,0 801217
A/I-DQ(ZN)BH 4 Multimode G62.5/125 OM1 4 7,8 1000 80,0 1,08 200 102,0 801218
A/I-DQ(ZN)BH 4 Single-mode E9/125 ITU-T G.652 4 7,8 1000 80,0 1,08 200 102,0 801219
A/I-DQ(ZN)BH 12 Multimode G50/125 OM2 12 7,8 1000 80,0 1,08 200 102,0 801220
A/I-DQ(ZN)BH 12 Multimode G62.5/125 OM1 12 7,8 1000 80,0 1,08 200 102,0 801221
A/I-DQ(ZN)BH 12 Single-mode E9/125 ITU-T G.652 12 7,8 1000 80,0 1,08 200 102,0 801190
Application
With the serie HELUCOM E30 we have realized, based on a special construction and high quality raw materials, a functional integrity according to
DIN 4102-12 E30 (30 minutes). Together with the planed accessories the cables realize the full function of the communication in areas like tunnels
or buildings for the defined period of time. On request we also can deliver cables with more than 12 fibres as stranded construction.
617
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A/I-D(ZN)BH(SR)H 4 Multimode G50/125 OM2 4 12,7 1500 180,0 6,20 300 216,0 803917
A/I-D(ZN)BH(SR)H 4 Single-mode E9/125 ITU-T G.652 4 12,7 1500 180,0 6,20 300 216,0 803919
A/I-D(ZN)BH(SR)H 12 Multimode G50/125 OM2 12 12,7 1500 180,0 6,20 300 216,0 803918
A/I-D(ZN)BH(SR)H 12 Single-mode E9/125 ITU-T G.652 12 12,7 1500 180,0 6,20 300 216,0 803920
Application
With the serie HELUCOM FS90 we have realized, based on a special construction and high quality raw materials, a functional integrity according to
IEC 60331-25 within 90, minutes (up to 750C). Together with the planed accessories the cables realize the full function of the communication in
areas like tunnels or buildings for the defined period of time.
618
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)2Y 2 Multimode G50/125 OM2 2 8,8 1500 130,0 1,60 250 40,0 80148
A-DQ(ZN)2Y 2 Multimode G62.5/125 OM1 2 8,8 1500 130,0 1,60 250 40,0 80164
A-DQ(ZN)2Y 2 Single-mode E9/125 ITU-T G.652 2 8,8 1500 130,0 1,60 250 40,0 80131
A-DQ(ZN)2Y 4 Multimode G50/125 OM2 4 8,8 1500 130,0 1,60 250 40,0 80149
A-DQ(ZN)2Y 4 Multimode G62.5/125 OM1 4 8,8 1500 130,0 1,60 250 40,0 80165
A-DQ(ZN)2Y 4 Single-mode E9/125 ITU-T G.652 4 8,8 1500 130,0 1,60 250 40,0 80132
A-DQ(ZN)2Y 6 Multimode G50/125 OM2 6 8,8 1500 130,0 1,60 250 40,0 80150
A-DQ(ZN)2Y 6 Multimode G62.5/125 OM1 6 8,8 1500 130,0 1,60 250 40,0 80166
A-DQ(ZN)2Y 6 Single-mode E9/125 ITU-T G.652 6 8,8 1500 130,0 1,60 250 40,0 80133
A-DQ(ZN)2Y 8 Multimode G50/125 OM2 8 8,8 1500 130,0 1,60 250 40,0 80151
A-DQ(ZN)2Y 8 Multimode G62.5/125 OM1 8 8,8 1500 130,0 1,60 250 40,0 80167
A-DQ(ZN)2Y 8 Single-mode E9/125 ITU-T G.652 8 8,8 1500 130,0 1,60 250 40,0 80134
A-DQ(ZN)2Y 12 Multimode G50/125 OM2 12 8,8 1500 130,0 1,60 250 40,0 80153
A-DQ(ZN)2Y 12 Multimode G62.5/125 OM1 12 8,8 1500 130,0 1,60 250 40,0 80169
A-DQ(ZN)2Y 12 Single-mode E9/125 ITU-T G.652 12 8,8 1500 130,0 1,60 250 40,0 80136
A-DQ(ZN)2Y 16 Multimode G50/125 OM2 16 8,8 1500 130,0 1,80 250 70,0 80154
A-DQ(ZN)2Y 16 Multimode G62.5/125 OM1 16 8,8 1500 130,0 1,80 250 70,0 80170
A-DQ(ZN)2Y 16 Single-mode E9/125 ITU-T G.652 16 8,8 1500 130,0 1,80 250 70,0 80137
A-DQ(ZN)2Y 24 Multimode G50/125 OM2 24 8,8 1500 130,0 1,80 250 70,0 80155
A-DQ(ZN)2Y 24 Multimode G62.5/125 OM1 24 8,8 1500 130,0 1,80 250 70,0 80171
A-DQ(ZN)2Y 24 Single-mode E9/125 ITU-T G.652 24 8,8 1500 130,0 1,80 250 70,0 80138
Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount. Around a central grooved cable, there is a
composite of glass yarns and swelling fleece with characteristics that ensure the actual strain relief and waterproofing in longitudinal direction of the
cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This construction is particularly used in
underground, tubes and channel areas, where rodent infestation is not to be expected.
619
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)2Y 24 Multimode G50/125 OM2 12 10,0 2500 200,0 2,50 400 70,0 80156
A-DQ(ZN)2Y 24 Multimode G62.5/125 OM1 12 10,0 2500 200,0 2,50 400 70,0 80172
A-DQ(ZN)2Y 24 Single-mode E9/125 ITU-T G.652 12 10,0 2500 200,0 2,50 400 70,0 80139
A-DQ(ZN)2Y 36 Multimode G50/125 OM2 12 10,0 2500 200,0 2,50 400 70,0 80448
A-DQ(ZN)2Y 36 Multimode G62.5/125 OM1 12 10,0 2500 200,0 2,50 400 70,0 80449
A-DQ(ZN)2Y 36 Single-mode E9/125 ITU-T G.652 12 10,0 2500 200,0 2,50 400 70,0 80450
A-DQ(ZN)2Y 48 Multimode G50/125 OM2 12 10,0 2500 200,0 2,50 400 70,0 80447
A-DQ(ZN)2Y 48 Multimode G62.5/125 OM1 12 10,0 2500 200,0 2,50 400 70,0 80446
A-DQ(ZN)2Y 48 Single-mode E9/125 ITU-T G.652 12 10,0 2500 200,0 2,50 400 70,0 80445
A-DQ(ZN)2Y 60 Multimode G50/125 OM2 12 10,0 2500 200,0 2,50 400 70,0 80159
A-DQ(ZN)2Y 60 Multimode G62.5/125 OM1 12 10,0 2500 200,0 2,50 400 70,0 80175
A-DQ(ZN)2Y 60 Single-mode E9/125 ITU-T G.652 12 10,0 2500 200,0 2,50 400 70,0 80142
A-DQ(ZN)2Y 72 Multimode G50/125 OM2 12 10,5 2500 210,0 2,60 400 75,0 80444
A-DQ(ZN)2Y 72 Multimode G62.5/125 OM1 12 10,5 2500 210,0 2,60 400 75,0 80443
A-DQ(ZN)2Y 72 Single-mode E9/125 ITU-T G.652 12 10,5 2500 210,0 2,60 400 75,0 80442
A-DQ(ZN)2Y 84 Multimode G50/125 OM2 12 11,5 2700 230,0 3,30 400 110,0 80160
A-DQ(ZN)2Y 84 Multimode G62.5/125 OM1 12 11,5 2700 230,0 3,30 400 110,0 80176
A-DQ(ZN)2Y 84 Single-mode E9/125 ITU-T G.652 12 11,5 2700 230,0 3,30 400 110,0 80143
A-DQ(ZN)2Y 96 Multimode G50/125 OM2 12 11,5 2700 230,0 3,30 400 110,0 80441
A-DQ(ZN)2Y 96 Multimode G62.5/125 OM1 12 11,5 2700 230,0 3,30 400 110,0 80440
A-DQ(ZN)2Y 96 Single-mode E9/125 ITU-T G.652 12 11,5 2700 230,0 3,30 400 110,0 80439
A-DQ(ZN)2Y 108 Multimode G50/125 OM2 12 13,0 2700 260,0 4,00 400 130,0 80161
A-DQ(ZN)2Y 108 Multimode G62.5/125 OM1 12 13,0 2700 260,0 4,00 400 130,0 80177
A-DQ(ZN)2Y 108 Single-mode E9/125 ITU-T G.652 12 13,0 2700 260,0 4,00 400 130,0 80144
A-DQ(ZN)2Y 120 Multimode G50/125 OM2 12 13,0 2700 260,0 4,00 400 130,0 80162
A-DQ(ZN)2Y 120 Multimode G62.5/125 OM1 12 13,0 2700 260,0 4,00 400 130,0 80178
A-DQ(ZN)2Y 120 Single-mode E9/125 ITU-T G.652 12 13,0 2700 260,0 4,00 400 130,0 80146
A-DQ(ZN)2Y 144 Multimode G50/125 OM2 12 14,0 2700 280,0 5,00 400 150,0 80438
A-DQ(ZN)2Y 144 Multimode G62.5/125 OM1 12 14,0 2700 280,0 5,00 400 150,0 80437
A-DQ(ZN)2Y 144 Single-mode E9/125 ITU-T G.652 12 14,0 2700 280,0 5,00 400 150,0 80436
Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount and extremely tension-resistant. Around a stranded
grooved cable and filler elements, there is a swelling fleece with characteristics that ensure strain relief and waterproofing in longitudinal direction of
the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This construction is particularly used in
underground, tubes and channel areas, where above-average tensile stresses and/or transverse compressions occur, but rodent infestation is not to
be expected.
620
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)B2Y 2 Multimode G50/125 OM2 2 7,5 1500 150,0 1,60 300 40,0 800754
A-DQ(ZN)B2Y 2 Multimode G62.5/125 OM1 2 7,5 1500 150,0 1,60 300 40,0 802131
A-DQ(ZN)B2Y 2 Single-mode E9/125 ITU-T G.652 2 7,5 1500 150,0 1,60 300 40,0 802137
A-DQ(ZN)B2Y 4 Multimode G50/125 OM2 4 7,5 1500 150,0 1,60 300 40,0 800755
A-DQ(ZN)B2Y 4 Multimode G62.5/125 OM1 4 7,5 1500 150,0 1,60 300 40,0 802132
A-DQ(ZN)B2Y 4 Single-mode E9/125 ITU-T G.652 4 7,5 1500 150,0 1,60 300 40,0 802138
A-DQ(ZN)B2Y 6 Multimode G50/125 OM2 6 7,5 1500 150,0 1,60 300 40,0 800756
A-DQ(ZN)B2Y 6 Multimode G62.5/125 OM1 6 7,5 1500 150,0 1,60 300 40,0 802133
A-DQ(ZN)B2Y 6 Single-mode E9/125 ITU-T G.652 6 7,5 1500 150,0 1,60 300 40,0 802139
A-DQ(ZN)B2Y 8 Multimode G50/125 OM2 8 7,5 1500 150,0 1,60 300 40,0 800757
A-DQ(ZN)B2Y 8 Multimode G62.5/125 OM1 8 7,5 1500 150,0 1,60 300 40,0 802134
A-DQ(ZN)B2Y 8 Single-mode E9/125 ITU-T G.652 8 7,5 1500 150,0 1,60 300 40,0 802140
A-DQ(ZN)B2Y 12 Multimode G50/125 OM2 12 7,5 1500 150,0 1,60 300 40,0 800759
A-DQ(ZN)B2Y 12 Multimode G62.5/125 OM1 12 7,5 1500 150,0 1,60 300 40,0 802135
A-DQ(ZN)B2Y 12 Single-mode E9/125 ITU-T G.652 12 7,5 1500 150,0 1,60 300 40,0 802141
A-DQ(ZN)B2Y 24 Multimode G50/125 OM2 24 8,5 1500 170,0 1,90 300 60,0 800762
A-DQ(ZN)B2Y 24 Multimode G62.5/125 OM1 24 8,5 1500 170,0 1,90 300 60,0 802136
A-DQ(ZN)B2Y 24 Single-mode E9/125 ITU-T G.652 24 8,5 1500 170,0 1,90 300 60,0 802142
Application
These HELUCOM pact fibre-optic cables are characterized by a design that is particularly easy to mount and is rodent-protected. Around a central
grooved cable, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent protection, strain relief, and waterproofing
in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This construction
is particularly used in underground, tubes and channel areas, where normal tensile stresses and/or transverse compressions occur and rodent infestation
is to be expected.
621
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)B2Y 2 Multimode G50/125 OM2 2 10,0 2500 160,0 1,60 300 85,0 80196
A-DQ(ZN)B2Y 2 Multimode G62.5/125 OM1 2 10,0 2500 160,0 1,60 300 85,0 80212
A-DQ(ZN)B2Y 2 Single-mode E9/125 ITU-T G.652 2 10,0 2500 160,0 1,60 300 85,0 80180
A-DQ(ZN)B2Y 4 Multimode G50/125 OM2 4 10,0 2500 160,0 1,60 300 85,0 80197
A-DQ(ZN)B2Y 4 Multimode G62.5/125 OM1 4 10,0 2500 160,0 1,60 300 85,0 80213
A-DQ(ZN)B2Y 4 Single-mode E9/125 ITU-T G.652 4 10,0 2500 160,0 1,60 300 85,0 80181
A-DQ(ZN)B2Y 6 Multimode G50/125 OM2 6 10,0 2500 160,0 1,60 300 85,0 80198
A-DQ(ZN)B2Y 6 Multimode G62.5/125 OM1 6 10,0 2500 160,0 1,60 300 85,0 80214
A-DQ(ZN)B2Y 6 Single-mode E9/125 ITU-T G.652 6 10,0 2500 160,0 1,60 300 85,0 80182
A-DQ(ZN)B2Y 8 Multimode G50/125 OM2 8 10,0 2500 160,0 1,60 300 85,0 80199
A-DQ(ZN)B2Y 8 Multimode G62.5/125 OM1 8 10,0 2500 160,0 1,60 300 85,0 80215
A-DQ(ZN)B2Y 8 Single-mode E9/125 ITU-T G.652 8 10,0 2500 160,0 1,60 300 85,0 80183
A-DQ(ZN)B2Y 12 Multimode G50/125 OM2 12 10,0 2500 160,0 1,60 300 85,0 80201
A-DQ(ZN)B2Y 12 Multimode G62.5/125 OM1 12 10,0 2500 160,0 1,60 300 85,0 80217
A-DQ(ZN)B2Y 12 Single-mode E9/125 ITU-T G.652 12 10,0 2500 160,0 1,60 300 85,0 80185
A-DQ(ZN)B2Y 16 Multimode G50/125 OM2 16 10,0 2500 180,0 1,80 300 95,0 80202
A-DQ(ZN)B2Y 16 Multimode G62.5/125 OM1 16 10,0 2500 180,0 1,80 300 95,0 80218
A-DQ(ZN)B2Y 16 Single-mode E9/125 ITU-T G.652 16 10,0 2500 180,0 1,80 300 95,0 80186
A-DQ(ZN)B2Y 24 Multimode G50/125 OM2 24 10,0 2500 180,0 1,80 300 95,0 80204
A-DQ(ZN)B2Y 24 Multimode G62.5/125 OM1 24 10,0 2500 180,0 1,80 300 95,0 80220
A-DQ(ZN)B2Y 24 Single-mode E9/125 ITU-T G.652 24 10,0 2500 180,0 1,80 300 95,0 80187
Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount and is rodent-protected. Around a central grooved
cable, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent protection, strain relief, and waterproofing in
longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore unnecessary. This construction
is particularly used in underground, tubes and channel areas, where normal tensile stresses and/or transverse compressions occur and rodent infestation
is to be expected.
622
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)B2Y 24 Multimode G50/125 OM2 12 10,5 2700 210,0 2,70 600 95,0 81382
A-DQ(ZN)B2Y 24 Multimode G62.5/125 OM1 12 10,5 2700 210,0 2,70 600 95,0 80219
A-DQ(ZN)B2Y 24 Single-mode E9/125 ITU-T G.652 12 10,5 2700 210,0 2,70 600 95,0 80188
A-DQ(ZN)B2Y 36 Multimode G50/125 OM2 12 10,5 2700 210,0 2,70 600 95,0 81108
A-DQ(ZN)B2Y 36 Multimode G62.5/125 OM1 12 10,5 2700 210,0 2,70 600 95,0 81109
A-DQ(ZN)B2Y 36 Single-mode E9/125 ITU-T G.652 12 10,5 2700 210,0 2,70 600 95,0 81110
A-DQ(ZN)B2Y 48 Multimode G50/125 OM2 12 10,5 2700 210,0 2,70 600 95,0 82648
A-DQ(ZN)B2Y 48 Multimode G62.5/125 OM1 12 10,5 2700 210,0 2,70 600 95,0 81112
A-DQ(ZN)B2Y 48 Single-mode E9/125 ITU-T G.652 12 10,5 2700 210,0 2,70 600 95,0 81113
A-DQ(ZN)B2Y 60 Multimode G50/125 OM2 12 10,5 2700 210,0 2,70 600 95,0 80207
A-DQ(ZN)B2Y 60 Multimode G62.5/125 OM1 12 10,5 2700 210,0 2,70 600 95,0 80223
A-DQ(ZN)B2Y 60 Single-mode E9/125 ITU-T G.652 12 10,5 2700 210,0 2,70 600 95,0 80191
A-DQ(ZN)B2Y 72 Multimode G50/125 OM2 12 11,0 2700 220,0 2,90 600 100,0 81133
A-DQ(ZN)B2Y 72 Multimode G62.5/125 OM1 12 11,0 2700 220,0 2,90 600 100,0 81134
A-DQ(ZN)B2Y 72 Single-mode E9/125 ITU-T G.652 12 11,0 2700 220,0 2,90 600 100,0 81120
A-DQ(ZN)B2Y 84 Multimode G50/125 OM2 12 12,0 3000 240,0 3,60 600 140,0 80208
A-DQ(ZN)B2Y 84 Multimode G62.5/125 OM1 12 12,0 3000 240,0 3,60 600 140,0 80224
A-DQ(ZN)B2Y 84 Single-mode E9/125 ITU-T G.652 12 12,0 3000 240,0 3,60 600 140,0 80192
A-DQ(ZN)B2Y 96 Multimode G50/125 OM2 12 12,0 3000 240,0 3,60 600 140,0 81135
A-DQ(ZN)B2Y 96 Multimode G62.5/125 OM1 12 12,0 3000 240,0 3,60 600 140,0 81136
A-DQ(ZN)B2Y 96 Single-mode E9/125 ITU-T G.652 12 12,0 3000 240,0 3,60 600 140,0 81121
A-DQ(ZN)B2Y 108 Multimode G50/125 OM2 12 13,5 3000 270,0 4,30 600 155,0 80209
A-DQ(ZN)B2Y 108 Multimode G62.5/125 OM1 12 13,5 3000 270,0 4,30 600 155,0 80225
A-DQ(ZN)B2Y 108 Single-mode E9/125 ITU-T G.652 12 13,5 3000 270,0 4,30 600 155,0 80193
A-DQ(ZN)B2Y 120 Multimode G50/125 OM2 12 13,5 3000 270,0 4,30 600 155,0 80210
A-DQ(ZN)B2Y 120 Multimode G62.5/125 OM1 12 13,5 3000 270,0 4,30 600 155,0 80226
A-DQ(ZN)B2Y 120 Single-mode E9/125 ITU-T G.652 12 13,5 3000 270,0 4,30 600 155,0 80194
A-DQ(ZN)B2Y 144 Multimode G50/125 OM2 12 14,5 3000 290,0 5,40 600 200,0 80211
A-DQ(ZN)B2Y 144 Multimode G62.5/125 OM1 12 14,5 3000 290,0 5,40 600 200,0 80227
A-DQ(ZN)B2Y 144 Single-mode E9/125 ITU-T G.652 12 14,5 3000 290,0 5,40 600 200,0 80195
623
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)B2Y 24 Single- and multimode OM2 + ITU-T 12 9,5 2500 200,0 2,50 400 90,0 803037
G50/125 G.652
A-DQ(ZN)B2Y 24 Single- und Multimode OM3 + ITU-T 12 9,5 2500 200,0 2,50 400 90,0 803923
G50/125 OM3 G.652
A-DQ(ZN)B2Y 48 Single- and multimode OM2 + ITU-T 12 9,5 2500 200,0 2,50 400 90,0 803038
G50/125 G.652
A-DQ(ZN)B2Y 48 Single- und Multimode OM3 + ITU-T 12 9,5 2500 200,0 2,50 400 90,0 803924
G50/125 OM3 G.652
Application
These HELUCOM pact fibre-optic cables are characterized by a design that is particularly easy to mount, tension-resistant and rodent-proof. Around
a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent protection,
strain relief and waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly off is therefore
unnecessary. This construction is particularly used in underground, tubes and channel areas, where packing density also plays a role.
624
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)B2Y 24 Single- and multimode OM2 + ITU-T 12 10,5 2700 200,0 2,70 600 95,0 81478
G50/125 G.652
A-DQ(ZN)B2Y 48 Single- and multimode OM2 + ITU-T 12 10,5 2700 200,0 2,70 600 95,0 801183
G50/125 G.652
Application
These HELUCOM fibre-optic cables are characterized by a design that is particularly easy to mount, extremely tension-resistant and rodent-proof.
Around a stranded grooved cable and filler elements, there is a composite of glass yarns and swelling fleece with characteristics that ensure rodent
protection, strain relief and waterproofing in longitudinal direction of the cable. In addition, these cables are designed grease-free. Wiping the jelly
off is therefore unnecessary. This construction is particularly used in underground, tubes and channel areas, where above-average tensile stresses
and/or transverse compressions occur and rodent infestation is to be expected.
625
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DF(ZN)2Y 2 Multimode G50/125 OM2 2 9,5 2500 95,0 4,20 400 85,0 80016
A-DF(ZN)2Y 2 Multimode G62.5/125 OM1 2 9,5 2500 95,0 4,20 400 85,0 80033
A-DF(ZN)2Y 2 Single-mode E9/125 ITU-T G.652 2 9,5 2500 95,0 4,20 400 85,0 80000
A-DF(ZN)2Y 4 Multimode G50/125 OM2 4 9,5 2500 95,0 4,20 400 85,0 80017
A-DF(ZN)2Y 4 Multimode G62.5/125 OM1 4 9,5 2500 95,0 4,20 400 85,0 80034
A-DF(ZN)2Y 4 Single-mode E9/125 ITU-T G.652 4 9,5 2500 95,0 4,20 400 85,0 80001
A-DF(ZN)2Y 8 Multimode G50/125 OM2 8 9,5 2500 95,0 4,20 400 85,0 80019
A-DF(ZN)2Y 8 Multimode G62.5/125 OM1 8 9,5 2500 95,0 4,20 400 85,0 80036
A-DF(ZN)2Y 8 Single-mode E9/125 ITU-T G.652 8 9,5 2500 95,0 4,20 400 85,0 80003
A-DF(ZN)2Y 12 Multimode G50/125 OM2 12 9,5 2500 95,0 4,20 400 85,0 80021
A-DF(ZN)2Y 12 Multimode G62.5/125 OM1 12 9,5 2500 95,0 4,20 400 85,0 80038
A-DF(ZN)2Y 12 Single-mode E9/125 ITU-T G.652 12 9,5 2500 95,0 4,20 400 85,0 80005
A-DF(ZN)2Y 24 Multimode G50/125 OM2 12 9,5 2700 95,0 4,00 400 85,0 80024
A-DF(ZN)2Y 24 Multimode G62.5/125 OM1 12 9,5 2700 95,0 4,00 400 85,0 80041
A-DF(ZN)2Y 24 Single-mode E9/125 ITU-T G.652 12 9,5 2700 95,0 4,00 400 85,0 80008
A-DF(ZN)2Y 36 Multimode G50/125 OM2 12 9,5 2700 95,0 4,00 400 85,0 80912
A-DF(ZN)2Y 36 Multimode G62.5/125 OM1 12 9,5 2700 95,0 4,00 400 85,0 80913
A-DF(ZN)2Y 36 Single-mode E9/125 ITU-T G.652 12 9,5 2700 95,0 4,00 400 85,0 80914
A-DF(ZN)2Y 48 Multimode G50/125 OM2 12 9,5 2700 95,0 4,00 400 85,0 80026
A-DF(ZN)2Y 48 Multimode G62.5/125 OM1 12 9,5 2700 95,0 4,00 400 85,0 80046
A-DF(ZN)2Y 48 Single-mode E9/125 ITU-T G.652 12 9,5 2700 95,0 4,00 400 85,0 80010
A-DF(ZN)2Y 60 Multimode G50/125 OM2 12 9,5 2700 95,0 4,00 400 85,0 80027
A-DF(ZN)2Y 60 Multimode G62.5/125 OM1 12 9,5 2700 95,0 4,00 400 85,0 80047
A-DF(ZN)2Y 60 Single-mode E9/125 ITU-T G.652 12 9,5 2700 95,0 4,00 400 85,0 80011
A-DF(ZN)2Y 72 Multimode G50/125 OM2 12 10,0 2700 100,0 3,80 400 90,0 80473
A-DF(ZN)2Y 72 Multimode G62.5/125 OM1 12 10,0 2700 100,0 3,80 400 90,0 80474
A-DF(ZN)2Y 72 Single-mode E9/125 ITU-T G.652 12 10,0 2700 100,0 3,80 400 90,0 80475
A-DF(ZN)2Y 84 Multimode G50/125 OM2 12 10,7 3000 107,0 4,30 400 120,0 80028
A-DF(ZN)2Y 84 Multimode G62.5/125 OM1 12 10,7 3000 107,0 4,30 400 120,0 80048
A-DF(ZN)2Y 84 Single-mode E9/125 ITU-T G.652 12 10,7 3000 107,0 4,30 400 120,0 80012
A-DF(ZN)2Y 96 Multimode G50/125 OM2 12 11,5 3000 115,0 5,00 400 135,0 80777
A-DF(ZN)2Y 96 Multimode G62.5/125 OM1 12 11,5 3000 115,0 5,00 400 135,0 80774
A-DF(ZN)2Y 96 Single-mode E9/125 ITU-T G.652 12 11,5 3000 115,0 5,00 400 135,0 80764
A-DF(ZN)2Y 144 Multimode G50/125 OM2 12 14,5 3000 145,0 7,70 400 175,0 80032
A-DF(ZN)2Y 144 Multimode G62.5/125 OM1 12 14,5 3000 145,0 7,70 400 175,0 80051
A-DF(ZN)2Y 144 Single-mode E9/125 ITU-T G.652 12 14,5 3000 145,0 7,70 400 175,0 80015
Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal direction
by filling a jelly mass into the stranding cavities. Non-metallic tension elements ensure above average strain relief. This construction is particularly used
in the area of telecommunication and long distance, but also in regular channels and tubes.
626
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DF(ZN)B2Y 2 Multimode G50/125 OM2 2 10,5 2700 105,0 4,40 400 90,0 80100
A-DF(ZN)B2Y 2 Multimode G62.5/125 OM1 2 10,5 2700 105,0 4,40 400 90,0 80115
A-DF(ZN)B2Y 2 Single-mode E9/125 ITU-T G.652 2 10,5 2700 105,0 4,40 400 90,0 80084
A-DF(ZN)B2Y 4 Multimode G50/125 OM2 4 10,5 2700 105,0 4,40 400 90,0 80101
A-DF(ZN)B2Y 4 Multimode G62.5/125 OM1 4 10,5 2700 105,0 4,40 400 90,0 80116
A-DF(ZN)B2Y 4 Single-mode E9/125 ITU-T G.652 4 10,5 2700 105,0 4,40 400 90,0 80085
A-DF(ZN)B2Y 8 Multimode G50/125 OM2 8 10,5 2700 105,0 4,40 400 90,0 80031
A-DF(ZN)B2Y 8 Multimode G62.5/125 OM1 8 10,5 2700 105,0 4,40 400 90,0 80771
A-DF(ZN)B2Y 8 Single-mode E9/125 ITU-T G.652 8 10,5 2700 105,0 4,40 400 90,0 80087
A-DF(ZN)B2Y 12 Multimode G50/125 OM2 12 10,5 2700 105,0 4,40 400 90,0 80104
A-DF(ZN)B2Y 12 Multimode G62.5/125 OM1 12 10,5 2700 105,0 4,40 400 90,0 80120
A-DF(ZN)B2Y 12 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 4,40 400 90,0 80089
A-DF(ZN)B2Y 24 Multimode G50/125 OM2 12 10,5 2700 105,0 4,40 400 90,0 80759
A-DF(ZN)B2Y 24 Multimode G62.5/125 OM1 12 10,5 2700 105,0 4,40 400 90,0 80123
A-DF(ZN)B2Y 24 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 4,40 400 90,0 80092
A-DF(ZN)B2Y 36 Multimode G50/125 OM2 12 10,5 2700 105,0 4,30 400 90,0 81137
A-DF(ZN)B2Y 36 Multimode G62.5/125 OM1 12 10,5 2700 105,0 4,30 400 90,0 81138
A-DF(ZN)B2Y 36 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 4,30 400 90,0 81139
A-DF(ZN)B2Y 48 Multimode G50/125 OM2 12 10,5 2700 105,0 4,20 400 90,0 80109
A-DF(ZN)B2Y 48 Multimode G62.5/125 OM1 12 10,5 2700 105,0 4,20 400 90,0 80125
A-DF(ZN)B2Y 48 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 4,20 400 90,0 80094
A-DF(ZN)B2Y 60 Multimode G50/125 OM2 12 10,5 2700 105,0 4,20 400 90,0 80110
A-DF(ZN)B2Y 60 Multimode G62.5/125 OM1 12 10,5 2700 105,0 4,20 400 90,0 80126
A-DF(ZN)B2Y 60 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 4,20 400 90,0 80095
A-DF(ZN)B2Y 72 Multimode G50/125 OM2 12 11,0 2700 110,0 4,10 400 95,0 81143
A-DF(ZN)B2Y 72 Multimode G62.5/125 OM1 12 11,0 2700 110,0 4,10 400 95,0 81144
A-DF(ZN)B2Y 72 Single-mode E9/125 ITU-T G.652 12 11,0 2700 110,0 4,10 400 95,0 81145
A-DF(ZN)B2Y 84 Multimode G50/125 OM2 12 11,5 3000 115,0 4,60 400 136,0 80111
A-DF(ZN)B2Y 84 Multimode G62.5/125 OM1 12 11,5 3000 115,0 4,60 400 136,0 80127
A-DF(ZN)B2Y 84 Single-mode E9/125 ITU-T G.652 12 11,5 3000 115,0 4,60 400 136,0 80096
A-DF(ZN)B2Y 96
A-DF(ZN)B2Y 96
Multimode G50/125
Multimode G62.5/125
OM2
OM1
12
12
12,0
12,0
3000
3000
120,0
120,0
5,30
5,30
400
400
155,0
155,0
81147
81148
R
A-DF(ZN)B2Y 96 Single-mode E9/125 ITU-T G.652 12 12,0 3000 120,0 5,30 400 155,0 81149
A-DF(ZN)B2Y 144 Multimode G50/125 OM2 12 14,5 3000 145,0 8,00 400 228,0 80114
A-DF(ZN)B2Y 144 Multimode G62.5/125 OM1 12 14,5 3000 145,0 8,00 400 228,0 80130
A-DF(ZN)B2Y 144 Single-mode E9/125 ITU-T G.652 12 14,5 3000 145,0 8,00 400 228,0 80099
Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal direction
by filling a jelly mass into the stranding cavities. Non-metallic tension elements and glass yarns ensure above average strain relief and rodent protection.
This construction is particularly used in the area of telecommunication and long distance, but also in regular channels and tubes where rodent infestation
is possible.
627
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DF(ZN)2Y4Y 2 Multimode G50/125 OM2 2 10,0 2700 100,0 6,10 400 90,0 80915
A-DF(ZN)2Y4Y 2 Multimode G62.5/125 OM1 2 10,0 2700 100,0 6,10 400 90,0 80927
A-DF(ZN)2Y4Y 2 Single-mode E9/125 ITU-T G.652 2 10,0 2700 100,0 6,10 400 90,0 80945
A-DF(ZN)2Y4Y 4 Multimode G50/125 OM2 4 10,0 2700 100,0 6,10 400 90,0 80735
A-DF(ZN)2Y4Y 4 Multimode G62.5/125 OM1 4 10,0 2700 100,0 6,10 400 90,0 80928
A-DF(ZN)2Y4Y 4 Single-mode E9/125 ITU-T G.652 4 10,0 2700 100,0 6,10 400 90,0 80895
A-DF(ZN)2Y4Y 8 Multimode G50/125 OM2 8 10,0 2700 100,0 6,10 400 90,0 80691
A-DF(ZN)2Y4Y 8 Multimode G62.5/125 OM1 8 10,0 2700 100,0 6,10 400 90,0 80809
A-DF(ZN)2Y4Y 8 Single-mode E9/125 ITU-T G.652 8 10,0 2700 100,0 6,10 400 90,0 80118
A-DF(ZN)2Y4Y 12 Multimode G50/125 OM2 12 10,0 2700 100,0 6,10 400 90,0 80627
A-DF(ZN)2Y4Y 12 Multimode G62.5/125 OM1 12 10,0 2700 100,0 6,10 400 90,0 80931
A-DF(ZN)2Y4Y 12 Single-mode E9/125 ITU-T G.652 12 10,0 2700 100,0 6,10 400 90,0 80947
A-DF(ZN)2Y4Y 24 Multimode G50/125 OM2 12 10,0 2700 100,0 6,10 400 90,0 80578
A-DF(ZN)2Y4Y 24 Multimode G62.5/125 OM1 12 10,0 2700 100,0 6,10 400 90,0 80576
A-DF(ZN)2Y4Y 24 Single-mode E9/125 ITU-T G.652 12 10,0 2700 100,0 6,10 400 90,0 80577
A-DF(ZN)2Y4Y 36 Multimode G50/125 OM2 12 10,0 2700 100,0 6,00 400 90,0 80672
A-DF(ZN)2Y4Y 36 Multimode G62.5/125 OM1 12 10,0 2700 100,0 6,00 400 90,0 80935
A-DF(ZN)2Y4Y 36 Single-mode E9/125 ITU-T G.652 12 10,0 2700 100,0 6,00 400 90,0 80950
A-DF(ZN)2Y4Y 48 Multimode G50/125 OM2 12 10,0 2700 100,0 6,00 400 90,0 80732
A-DF(ZN)2Y4Y 48 Multimode G62.5/125 OM1 12 10,0 2700 100,0 6,00 400 90,0 80936
A-DF(ZN)2Y4Y 48 Single-mode E9/125 ITU-T G.652 12 10,0 2700 100,0 6,00 400 90,0 80951
A-DF(ZN)2Y4Y 60 Multimode G50/125 OM2 12 10,0 2700 100,0 5,80 400 90,0 80920
A-DF(ZN)2Y4Y 60 Multimode G62.5/125 OM1 12 10,0 2700 100,0 5,80 400 90,0 80938
A-DF(ZN)2Y4Y 72 Multimode G50/125 OM2 12 10,5 2700 105,0 5,80 400 95,0 80921
A-DF(ZN)2Y4Y 72 Multimode G62.5/125 OM1 12 10,5 2700 105,0 5,80 400 95,0 80939
A-DF(ZN)2Y4Y 72 Single-mode E9/125 ITU-T G.652 12 10,5 2700 105,0 5,80 400 95,0 80954
A-DF(ZN)2Y4Y 84 Multimode G50/125 OM2 12 11,0 3000 110,0 8,40 400 110,0 80922
A-DF(ZN)2Y4Y 84 Multimode G62.5/125 OM1 12 11,0 3000 110,0 8,40 400 110,0 80940
A-DF(ZN)2Y4Y 84 Single-mode E9/125 ITU-T G.652 12 11,0 3000 110,0 8,40 400 110,0 80955
A-DF(ZN)2Y4Y 96 Multimode G50/125 OM2 12 11,5 3000 115,0 7,20 400 120,0 80923
A-DF(ZN)2Y4Y 96 Multimode G62.5/125 OM1 12 11,5 3000 115,0 7,20 400 120,0 80941
A-DF(ZN)2Y4Y 96 Single-mode E9/125 ITU-T G.652 12 11,5 3000 115,0 7,20 400 120,0 80956
A-DF(ZN)2Y4Y 144 Multimode G50/125 OM2 12 14,5 3000 145,0 10,40 400 180,0 80926
A-DF(ZN)2Y4Y 144 Multimode G62.5/125 OM1 12 14,5 3000 145,0 10,40 400 180,0 80944
A-DF(ZN)2Y4Y 144 Single-mode E9/125 ITU-T G.652 12 14,5 3000 145,0 10,40 400 180,0 80959
Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal direction
by filling a jelly mass into the stranding cavities. Non-metallic tension elements and a second outer sheath made of polyamide (PA) ensure above
average strain relief and rodent protection. This construction is particularly used in the area of telecommunication and long distance, but also in regular
channels and tubes where rodent infestation is possible.
628
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ2Y 4 Single-mode E9/125 ITU-T G.652 4 2,5 180 40,0 1,40 100 6,0 803664
central
A-DQ2Y 12 Single-mode E9/125 ITU-T G.652 12 2,5 180 40,0 1,40 100 6,0 803929
central
Application
These HELUCOM micro fibre-optic cables are characterized by a design that is slim but robust. Around a central tube, there is a composite of swelling
fleece with characteristics that ensure the strain relief, and waterproofing in longitudinal direction of the cable. This construction is particularly used
in tubes and channels. These cables can be blowing into microducts.
629
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ2Y 4 Single-mode E9/125 ITU-T G.652 4 5,8 850 70,0 0,89 150 27,0 803931
stranded
A-DQ2Y 12 Single-mode E9/125 ITU-T G.652 12 5,8 850 70,0 0,87 150 27,0 803932
stranded
A-DQ2Y 24 Single-mode E9/125 ITU-T G.652 12 5,8 850 70,0 0,87 150 27,0 803930
stranded
A-DQ2Y 48 Single-mode E9/125 ITU-T G.652 12 5,8 850 70,0 0,87 150 27,0 803658
stranded
A-DQ2Y 72 Single-mode E9/125 ITU-T G.652 12 5,8 850 60,0 0,87 150 27,0 803659
stranded
A-DQ2Y 96 Single-mode E9/125 ITU-T G.652 12 6,8 1000 70,0 1,25 150 40,0 803660
stranded
A-DQ2Y 144 Single-mode E9/125 ITU-T G.652 12 9,4 1800 140,0 2,19 150 79,0 803661
stranded
A-DQ2Y 288 Single-mode E9/125 ITU-T G.652 12 11,2 1500 115,0 2,97 100 90,0 803668
stranded
Application
These HELUCOM micro fibre-optic cables are characterized by a design that is slim but robust. Around stranded tubes, there is a composite of swelling
fleece with characteristics that ensure the strain relief, and waterproofing in longitudinal direction of the cable. This construction is particularly used
in tubes and channels. These cables can be blowing into microducts.
630
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DQ(ZN)(SR)2Y 4 Multimode G50/125 OM2 4 9,5 1500 95,0 2,00 500 115,0 802917
A-DQ(ZN)(SR)2Y 4 Multimode G62.5/125 OM1 4 9,5 1500 95,0 2,00 500 115,0 803925
A-DQ(ZN)(SR)2Y 4 Single-mode E9/125 ITU-T G.652 4 9,5 1500 95,0 2,00 500 105,0 803927
A-DQ(ZN)(SR)2Y 12 Multimode G50/125 OM2 12 9,5 1500 95,0 2,00 500 115,0 802918
A-DQ(ZN)(SR)2Y 12 Multimode G62.5/125 OM1 12 9,5 1500 95,0 2,00 500 115,0 803926
A-DQ(ZN)(SR)2Y 12 Single-mode E9/125 ITU-T G.652 12 9,5 1500 95,0 2,00 500 115,0 803928
Application
These HELUCOM fibre-optic cables are characterized by a compact construction with a swelling fleece. Above-average rodent protection is achieved
with the metallic rodent protection (steel groove) and an outer sheath made of PE. This construction is particularly used in the area of telecommunication
and long distance, but also in regular channels and tubes where rodent infestation is possible.
631
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type Fibre category Number of Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres fibres per app. mm tensile bending app. MJ / m transverse kg / km
core force N radius pressure
mm N / cm
A-DF(ZN)2Y(SR)2Y 12 Single-mode E9/125 ITU-T G.652 2 13,0 2700 130,0 0,00 800 180,0 82190
A-DF(ZN)2Y(SR)2Y 24 Single-mode E9/125 ITU-T G.652 4 13,0 2700 130,0 0,00 800 180,0 800708
A-DF(ZN)2Y(SR)2Y 48 Single-mode E9/125 ITU-T G.652 12 13,0 2700 130,0 0,00 800 180,0 800709
A-DF(ZN)2Y(SR)2Y 60 Single-mode E9/125 ITU-T G.652 12 13,0 2700 130,0 0,00 800 180,0 800710
Application
These HELUCOM fibre-optic cables are characterized by a stranded construction with jelly filling. They are made waterproof in longitudinal direction
by filling a jelly mass into the stranding cavities. Above-average rodent protection is achieved with the metallic rodent protection (steel groove) and
the second outer sheath made of PE. This construction is particularly used in the area of telecommunication and long distance where ARCOR standards
must be followed, but also in regular channels and tubes where rodent infestation is possible.
632
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation No. of Fibre type No. of Dimensions Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres copper of copper app. mm tensile bending app. MJ / m transverse kg / km
cores cores force N radius pressure
mm mm N / cm
A-DSQ(ZN)B2Y 4 Multimode G50/125 2 1,2 12,0 2100 300 4,80 200 140,0 81209
A-DSQ(ZN)B2Y 4 Multimode G62.5/125 2 1,2 12,0 2100 300 4,80 200 140,0 81255
A-DSQ(ZN)B2Y 4 Single-mode E9/125 2 1,2 12,0 2100 300 4,80 200 140,0 81256
A-DSQ(ZN)B2Y 4 Multimode G50/125 2 1,5 12,5 2300 320 4,80 200 160,0 82561
A-DSQ(ZN)B2Y 4 Multimode G62.5/125 2 1,5 12,5 2300 320 4,80 200 160,0 81257
A-DSQ(ZN)B2Y 4 Single-mode E9/125 2 1,5 12,5 2300 320 4,80 200 160,0 81258
A-DSQ(ZN)B2Y 4 Multimode G50/125 4 1,5 17,0 2600 430 5,80 200 250,0 82786
A-DSQ(ZN)B2Y 4 Multimode G62.5/125 4 1,5 17,0 2600 430 5,80 200 250,0 81259
A-DSQ(ZN)B2Y 4 Single-mode E9/125 4 1,5 17,0 2600 430 5,80 200 250,0 81260
Application
These HELUCOM fibre-optic cables are designed especially for use in fibre-optical temperature measurements, such as monitoring of dams. The
extreme mechanical requirements in these areas are fulfilled by the specially designed cable construction. These lines are hybrid glass fibre lines with
copper cores and a special PE outer sheath.
633
Data, Network and Bus Technology / HELUKAT Copper data cables
Designation No. of Fibre type No. of Dimensions Outer Max. Min. stat. Caloric load Max. Weight Part no.
fibres copper of copper app. mm tensile bending app. MJ / m transverse kg / km
cores cores force N radius pressure
mm mm N / cm
A-DSF(L)(ZN)2Y 12 Single-mode E9/125 2 0,6 12,0 2500 200 4,80 250 135,0 80495
A-DSF(L)(ZN)2Y 12 Single-mode E9/125 4 0,6 12,0 2500 200 4,80 250 140,0 80497
A-DSF(L)(ZN)2Y 24 Single-mode E9/125 2 0,6 13,1 2500 200 4,80 250 139,0 800753
A-DSF(L)(ZN)2Y 24 Single-mode E9/125 4 0,6 13,1 2500 200 4,80 250 144,0 801182
A-DSF(L)(ZN)2Y 48 Single-mode E9/125 2 0,6 13,1 2500 200 4,80 250 141,0 80501
A-DSF(L)(ZN)2Y 48 Single-mode E9/125 4 0,6 13,1 2500 200 4,80 250 146,0 80503
A-DSF(L)(ZN)2Y 60 Single-mode E9/125 2 0,6 14,1 2500 230 4,80 250 166,0 80504
A-DSF(L)(ZN)2Y 60 Single-mode E9/125 4 0,6 14,1 2500 230 4,80 250 171,0 80506
A-DSF(L)(ZN)2Y 72 Single-mode E9/125 2 0,6 14,8 2500 240 5,10 250 179,0 80507
A-DSF(L)(ZN)2Y 72 Single-mode E9/125 4 0,6 14,8 2500 240 5,10 250 184,0 80509
A-DSF(L)(ZN)2Y 96 Single-mode E9/125 2 0,6 16,6 3000 280 6,30 250 276,0 80510
A-DSF(L)(ZN)2Y 96 Single-mode E9/125 4 0,6 16,6 3000 280 6,30 250 281,0 80512
A-DSF(L)(ZN)2Y 120 Single-mode E9/125 2 0,6 18,4 3000 290 8,50 250 280,0 80513
A-DSF(L)(ZN)2Y 120 Single-mode E9/125 4 0,6 18,4 3000 290 8,50 250 285,0 80515
A-DSF(L)(ZN)2Y 144 Single-mode E9/125 2 0,6 20,3 3500 310 10,00 250 331,0 80516
A-DSF(L)(ZN)2Y 144 Single-mode E9/125 4 0,6 20,3 3500 310 10,00 250 336,0 80518
Application
These HELUCOM outdoor cables are designed for use under extreme environmental conditions. With the double jelly filling and the Al/PE laminated
sheath, they are water proof in longitudinal and transverse direction. The welded Al tape acts as an additional vapour barrier. These cables can be
layed directly in the ground, in tubes and in ducts. They are mainly used in local and long-distance networks.
634
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Number of Span width Max. Additional Min. stat. Outer Weight Part no.
fibres fibres per m tensile load bending app. mm kg / km
core force kN daN / m radius
mm
ADSS 9 12 Single-mode E9/125 4 150 9 0,5 410 13,6 135 82390
ADSS 9 24 Single-mode E9/125 4 150 9 0,5 410 13,6 137 82391
ADSS 9 36 Single-mode E9/125 6 150 9 0,5 470 15,6 177 82392
ADSS 9 48 Single-mode E9/125 8 150 9 0,5 470 15,6 178 82393
ADSS 9 60 Single-mode E9/125 12 150 9 0,5 450 15,0 161 82394
ADSS 9 144 Single-mode E9/125 12 150 9 0,5 630 20,8 316 82395
Application
These HELUCOM outdoor cables designed as aerial cables for freely suspended installations on posts and masts. The construction is waterproof in
longitudinal direction thanks to the use of jelly-filled bundle cores and swelling tape. The outer jacket is UV-resistant and at the same time provides
protection against environmental influences, such as snow, ice, sun insolation and wind.
635
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Outer Outer Min. stat. Flame halogen- UL Weight Part no.
fibres app. mm sheath bending proof free kg / km
material radius
mm
Fibre-optic cable 2 Multimode G50/125 5,0 PUR 75 yes yes no 20 80382
Fibre-optic cable 2 Multimode G62.5/125 5,0 PUR 75 yes yes no 20 80363
Fibre-optic cable 4 Multimode G50/125 5,8 PUR 90 yes yes no 31 80534
Fibre-optic cable 4 Multimode G62.5/125 5,8 PUR 90 yes yes no 31 81036
Fibre-optic cable 4 Single-mode E9/125 5,8 PUR 90 yes yes no 31 801727
Fibre-optic cable 8 Multimode G50/125 7,0 PUR 105 yes yes no 47 81037
Fibre-optic cable 8 Multimode G62.5/125 7,0 PUR 105 yes yes no 47 81038
Application
These HELUCOM cables were designed as mobile field cables. They are easily wound up on a drum and are very tension-proof. As the outer sheath
is tightly anchored on the aramid braiding, it is especially suitable for mobile use. The advantage of these cables is evident especially where mobile
fibre-optic lines are to be installed, such as for drag chains, TV transmission, supervision of protected areas, etc.
636
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Outer Outer Inner Min. stat. Flame halogen- UL Weight Part no.
fibres app. mm sheath sheath bending proof free kg / km
material material radius
mm
Fibre-optic cable 4 Multimode G50/125 7,0 PVC PVC 75 yes no yes 50 802792
Fibre-optic cable 4 Multimode G62.5/125 7,0 PVC PVC 75 yes no yes 50 803934
Fibre-optic cable 4 Single-mode E9/125 7,0 PVC PVC 75 yes no yes 50 803935
Application
These HELUCOM cables were designed as mobile field cables. They are easily wound up on a drum and are very tension-proof. As the outer sheath
is tightly anchored on the aramid braiding, it is especially suitable for mobile use. The advantage of these cables is evident especially where mobile
fibre-optic lines are to be installed, such as windturbine projects, TV transmission, supervision of protected areas, etc.. This series with PVC jacket is
certified according the UL/CSA standard OFNG/ FT4.
637
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Outer Outer Inner Min. stat. Flame halogen- UL Weight Part no.
fibres app. mm sheath sheath bending proof free kg / km
material material radius
mm
AT-V(ZN)H(ZN)11Y 4 Multimode G50/125 8,5 PUR ULSZH 100 yes yes no 125 803346
AT-V(ZN)Y(ZN)Y 4 Multimode G50/125 8,5 PVC PVC 130 yes no yes 125 803348
AT-V(ZN)Y(ZN)Y 12 Multimode G50/125 12,4 PVC PVC 190 yes no yes 320 803349
AT-V(ZN)H(ZN)11Y 12 Multimode G50/125 12,4 PUR ULSZH 190 yes yes no 320 803347
AT-V(ZN)H(ZN)11Y 12 Single-mode E9/125 12,4 PUR ULSZH 190 yes yes no 320 804700
Application
The HELUCOM WK range is set apart by its extreme rugged yet highly-flexible design. It is used wherever demanding environmental conditions and
extreme movements occur. The tight buffer structure enables the cable to be pre-assembled on site with ease. Applications are for example Windturbines,
TV transmissions, mobile field applications, etc..
638
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Outer Outer Inner Min. stat. Flame halogen- UL Weight Part no.
fibres app. mm sheath sheath bending proof free kg / km
material material radius
mm
Fibre-optic cable 4 Multimode G50/125 7,4 PVC PVC 90 yes no no 65 803364
Application
The HELUCOM range is set apart by its extreme rugged yet flexible design. It is used wherever demanding environmental conditions and movements
occur. The tight buffer structure enables the cable to be pre-assembled on site with ease. Applications are for example industry applications, TV
transmissions, etc..
639
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres app. mm tensile bending transverse app. MJ / m kg / km
force N radius pressure
mm N / cm
AT-V(ZN)HH(ZN)B2Y 4 Multimode G50/125 13,5 1200 340 300 2,95 140 801352
Application
The HELUCOM range is set apart by its extreme rugged roden protected design. It is used wherever demanding environmental conditions while fixed
installations occur. The tight buffer structure enables the cable to be pre-assembled on site with ease. Applications are for example industry applications,
etc..
640
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
AT-VYY 2 Multimode G62.5/125 1 6,8 x 10,2 400 110,0 300 1,10 76,0 800126
Application
This HELUCOM fibre-optic cable is suited for fixed installations in pits and channels, but also for flexible applications as jumper cable. Because of the
robust construction with Single- and Overall-jacket you also can use it in industrial areas. With the core-construction, direct plug manufacturing, even
on site, poses no problems.
641
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres app. mm tensile bending radius transverse app. MJ / m kg / km
force N mm pressure
N / cm
I-VH 1 HCS 200/230 2,8 300 40 10 0,26 2,8 800579
I-VHH 2 HCS 200/230 3,8 x 6,6 600 50 10 0,52 30,0 81238
Application
These HELUCOM HCS fibre lines are suitable for stationary installation indoors. For heavy-duty mechanical requirements, such as application in
industrial environments, a version with PUR outer sheath is available on request. With a HCS fibre transmission lengths of up to 300m can be achieved.
With the tight buffer construction, direct plug manufacturing, even on site, poses no problems.
642
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
AT-V(ZN)HH 4 HCS 200/230 1 9,0 800 225,0 100 1,60 76,0 802260
Application
This HELUCOM HCS fibre cable is suitable for fixed and normal flexible installation. Possible applications are normal requirements and also limited
industrial environments. With the tight buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission
lengths of up to 300m can be achieved.
643
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
I-V(ZN)YY 2 HCS 200/230 1 7,5 800 100,0 300 1,40 68,0 801733
Application
This HELUCOM HCS fibre cable is suitable for fixed and normal flexible installations. Possible applications are normal and heavy-duty mechanical
requirements for example in industrial environments. Because of a special PVC jacket this construction is certified by UL (FT1 and FT4). With the tight
buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission lengths of up to 300m can be achieved.
644
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
I-V(ZN)Y11Y 2 HCS 200/230 1 7,0 800 50,0 150 1,014 43,0 800980
Application
This HELUCOM HCS fibre cable is suitable for fixed installation. Possible applications are normal and heavy-duty mechanical requirements for example
in industrial environments. With the tight buffer construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission
lengths of up to 300m can be achieved.
645
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
AT-VQH(ZN)B2Y 2 HCS 200/230 1 11,0 1500 200,0 500 2,10 90,0 801196
Application
This HELUCOM HCS fibre cable is suitable for fixed installation outdoors. Possible applications are normal and heavy-duty mechanical requirements
for example in industrial environments. This is the reason we also equiped the cable with a non-metallic rodent-protection.With the tight buffer
construction, direct plug manufacturing, even on site, poses no problems. With a HCS fibre transmission lengths of up to 300m can be achieved.
646
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Number of Fibre type Number of Outer Max. Min. stat. Max. Caloric load Weight Part no.
fibres fibres per app. mm tensile bending transverse app. MJ / m kg / km
core force N radius pressure
mm N / cm
A/I-DQ(ZN)BH 4 HCS 200/230 4 8,5 1500 130,0 150 2,00 76,0 801198
A/I-DQ(ZN)BH 8 HCS 200/230 8 8,5 1500 130,0 150 2,00 79,0 802001
A/I-DQ(ZN)BH 12 HCS 200/230 12 8,5 1500 130,0 150 2,00 82,0 802002
A/I-DQ(ZN)BH 24 HCS 200/230 8 17,7 6000 265,0 300 3,20 280,0 802003
A/I-DQ(ZN)BH 48 HCS 200/230 8 18,9 6000 285,0 300 3,20 355,0 802004
Application
These HELUCOM fibre-optic cables are available either as central bundle core cable or as stranded versions. They are suitable for fixed indoor and
outdoor cabling of buildings and industry facilities. They are used in particular if the installation is to be done in one piece from the inside to the outside
without additional use of couplings. With their black UV-resistant outer sheath and the non-metallic rodent protection, they are perfectly suited for
outdoor use. The halogen-free outer sheath makes installation inhouse possible without any problems.
647
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Outer Sheath Outer Max. Min. stat. Fibre Oil- Acc. to Weight Part no.
sheath colour app. mm tensile bending attenuation resistant DESINA kg / km
material force N radius
mm
I-V2Y 1P 980/1000 PE Black 2,2 70 25,0 160A1 no no 4,0 80532
I-V2Y 2P 980/1000 PE Black 2,2 x 4,4 140 25,0 160A1 no no 8,0 80388
I-V2Y(ZN)11Y 1P 980/1000 PUR Violet 5,8 400 30,0 230A1 yes yes 30,0 81611
I-V2Y(ZN)11Y 2P 980/1000 PUR Violet 6,0 400 31,0 230A1 yes yes 36,0 80629
I-V2Y(ZN)11Y 2P 980/1000 PUR Violet 6,0 400 31,0 230A1 yes yes 36,0 81882
I-V2Y(ZN)11Y 4P 980/1000 PUR Violet 7,1 400 45,0 230A1 yes yes 65,0 80630
I-V2Y(ZN)11Y 2P 980/1000 + 2x1mm Cu PUR Red 7,8 200 70,0 230A1 yes no 60,0 82032
I-V2Y(ZN)11Y 2P 980/1000 + 3x1,5mm Cu PUR Red 11,0 200 70,0 230A1 yes no 132,0 82033
Application
HELUCOM plastic-fibre cables are used in mechanical engineering, both in mobile and fixed applications. With different constructions, such as PUR
outer sheaths, special strain relief components, hybrid construction with copper cores for power supply or only raw fibre cables, any possible fields
of application are covered. Due to their solidity and their simple adjustability on site, the plastic-fibres (PMMA) are particularly suitable for applications
where trouble-free data transmission in necessary under heavy-duty conditions.
648
Data, Network and Bus Technology / HELUCOM Fibre Optic cables
Designation Outer Sheath Outer Max. Min. stat. Fibre Oil- Acc. to Weight Part no.
sheath colour app. mm tensile bending attenuation resistant DESINA kg / km
material force N radius
mm
I-V4Y(ZN)11Y 2P980/1000 RUGGED PUR Red 8,0 100 50,0 160A1 yes no 42,0 801200
I-V4Y(ZN)11Y 2P980/1000 FLEX RUGGED PUR Red 8,0 100 50,0 250A1 yes no 51,0 801201
I-V4Y(ZN)11Y 2P980/1000 HEAVY PUR Red 6,0 100 30,0 160A1 yes no 28,0 801202
Application
Signal lines as plastic optical fibre. The use of these transmission systems significantly reduces the number of different cables in a planned bus installation
in machine tools operations. Furthermore, possible EMC problems are prevented by the metal-free construction. The main application of these cables
are in machine construction and automobile industry (PA version).
649
FIBRESPECIFICATIONS
Granded index fibres (multimode)
Specification Fibre type G 50/125 Fibre type G 62,5/125
Fibre catergorie OM2 Standardfibre OM1 Standardfibre
Core diameter 50 + 3 m 62,5 + 3 m
Numerical aperture 0,200 + 0,015 0,275 + 0,015
Typ. attenuation 850 nm 2,8 dB/km 3,0 dB/km
1300 nm 0,7 dB/km 1,0 dB/km
Min. bandwidth 850 nm 500 MHz x km 200 MHz x km
1300 nm 800 MHz x km 500 MHz x km
Cladding diameter 125 + 1 m
Primary coating diameter 245 + 10 m
Core noncircularity <5%
Cladding concentricity error < 3,0 m
Cladding noncircularity < 2,0 %
Single-Mode-Fibre
Specification Fibre type E9...10/125 (single mode)
Fibre catergorie ITU-T G. 652.d
Attenuation 1300 nm 0,36 dB/km
1550 nm 0,22 dB/km
Dispersion 1285 - 1330 nm < 3,5 ps/(nm x km)
1550 nm < 19 ps/(nm x km)
Wave length 1312 nm
Mode field diameter at 1310 nm 9,3 + 0,5 m
Cladding diameter 125 + 1 m
Primary coating diameter 245 + 10 m
Cut-off wavelength < 1250 nm
Cladding concentricity error < 0,8 m
Cladding noncircularity < 1,0 %
650
FIBRE OPTIC DESIGN CODE acc. to DIN VDE 0888
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Lg layerstranding
Wavelength
B = 850 nm
F = 1300 nm
H = 1550 nm
Cladding diameter in m
Design
E Single mode fibre
G Graded index fibre
Number of fibres
Number of fibres per buffer
Number of multifibre buffer
Y PVC-sheath
H Sheath with halogenfree material
B Armouring
BY Armouring with PVC-protective covering sheath
B2Y Armouring with PE-protective covering sheath
Y PVC-sheath
2Y PE-sheath
4Y PA-sheath
11Y PUR-sheath
(L)2Y PE-Laminated sheath
(ZN)2Y PE-sheath with nometallic strength member
(L)(ZN)2Y PE-Laminated sheath with nonmetallic strength member
651
COPPER DATA CABLES HELUKAT
Designation Page
653
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 5e 155
U/UTP
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 155 MHz
Loop resistance: 190 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 66 %
Typical values
Frequency (MHz) 10 16 62,5 100 155
Attenuation (dB/100m) 6,3 8,0 16,5 21,3 26,8
Next (db) 50,3 47,3 38,4 35,3 33,0
ACR (db) 44,0 39,3 21,9 14,0 6,2
Technical data
Weight: app. 26 kg/km
bending radius, repeated: 40 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,40 MJ/m
Copper weight: 17,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e
Application
HELUKAT155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s, or
ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels and platforms due
to their optimized construction.
654
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 5e 155
U/UTP UL
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 155 MHz
Loop resistance: 190 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 66 %
Typical values
Frequency (MHz) 10 16 62,5 100 155
Attenuation (db/100m) 6,1 7,7 15,2 19,9 22,7
Next (db) 65,0 63,0 53,0 40,0 37,0
ACR (db) 58,9 55,3 37,8 20,1 14,3
Technical data
Weight: app. 35 kg/km
bending radius, repeated: 42 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,43 MJ/m
Copper weight: 17,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444
Application
HELUKAT155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves R
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction. This type is certified according UL because of the special PVC jacket
655
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 6 300
U/UTP UL
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 300 MHz
Loop resistance: 190 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 67 %
Typical values
Frequency (MHz) 10 16 62,5 100 155 200 300
Attenuation (db/100m) 5,6 7,0 14,3 18,2 22,9 26,0 32,5
Next (db) 72,0 70,0 65,0 63,0 60,0 57,0 55,0
ACR (db) 66,4 63,0 50,7 44,8 37,1 31,0 22,5
Technical data
Weight: app. 46 kg/km
bending radius, repeated: 55 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,68 MJ/m
Copper weight: 20,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444
Application
HELUKAT300 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction. This type is certified according UL because of the special PVC jacket
656
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN-Cable
Category 5 100
U/UTP flex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 74 %
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/10m) 0,9 1,2 2,4 3,1
Next (db) 53,0 50,0 41,0 38,0
ACR (db) 52,1 48,8 38,6 34,9
Technical data
Weight: app. 17 kg/km
bending radius, repeated: 35 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,527 MJ/m
Copper weight: 11,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5
Application
R
HELUKAT100 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16
Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT100 series can be manufactured quickly and easily with all
common RJ45 plugs.
657
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 5e 155
F/UTP
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 155 MHz
Loop resistance: 170 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 69 %
Typical values
Frequency (MHz) 10 16 62,5 100 155
Attenuation (dB/100m) 5,9 7,6 15,7 20,3 22,0
Next (db) 59,0 53,0 44,0 40,0 40,0
ACR (db) 53,1 45,4 28,3 19,7 18,0
Technical data
Weight: app. 40 kg/km
bending radius, repeated: 48 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,40 MJ/m
Copper weight: 18,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e
Application
HELUKAT155 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16 Mbit/s, or
ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels and platforms due
to their optimized construction.
658
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 5 100
F/UTP flex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 74 %
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/10m) 0,9 1,2 2,4 2,9
Next (db) 58,0 56,0 45,0 43,0
ACR (db) 57,1 54,8 42,6 40,1
Technical data
Weight: app. 31 kg/km
bending radius, repeated: 40 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,45 MJ/m
Copper weight: 14,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT100 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance R
reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16
Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT100 series can be manufactured quickly and easily with all
common RJ45 plugs.
659
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 5 100
F/UTP FE60
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 188 Ohm/km max.
Mutual capacitance: 65 nF/km nom.
Rel. propagation velocity: 67 %
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 5,7 7,3 14,9 19,3
Next (db) 56,0 53,0 42,0 38,0
ACR (db) 50,3 45,7 27,1 18,7
Technical data
Weight: app. 75 kg/km
bending radius, repeated: 130 mm
Operating temperature range min.: -20C
Operating temperature range max.: +70C
Caloric load, approx. value: 0,72 MJ/m
Copper weight: 24,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT100-FE60 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Fast Ethernet, Ethernet, ATM155, FDDI, token ring 4/16
Mbit/s, or ISDN absolutely trouble-free. Likewise, the thermal characteristics are perfectly suited to realize an isolation integrity according EN50200-FE60
due to their optimized construction.
660
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 5e 200
F/UTP Flex, UL
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 200 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Rel. propagation velocity: 67 %
Typical values
Frequency (MHz) 10 16 62,5 100 200
Attenuation (db/10m) 0,9 1,2 2,4 3,1 3,9
Next (db) 62,0 60,0 50,0 48,0 45,0
ACR (db) 61,1 58,8 47,6 44,9 41,1
Technical data
Weight: app. 30 kg/km
bending radius, repeated: 44 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,40 MJ/m
Copper weight: 15,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444
Application R
HELUKAT200 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI,
token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT200 series can be manufactured quickly and
easily with all common RJ45 plugs. This type is certified according UL because of the special PVC jacket.
661
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 5e 200
SF/UTP
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 200 MHz
Loop resistance: 185 Ohm/km max.
Mutual capacitance: 48 nF/km nom.
Rel. propagation velocity: 74 %
Typical values
Frequency (MHz) 10 16 62,5 100 200
Attenuation (dB/100m) 5,6 7,2 14,4 18,2 25,9
Next (db) 62,0 59,0 50,0 46,0 40,0
ACR (db) 56,4 51,8 35,6 27,8 14,6
Technical data
Weight: app. 50 kg/km
bending radius, repeated: 52 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,60 MJ/m / 0,48 MJ/m
Copper weight: 28,00 kg/km
Norms
81610:
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e
81609:
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant:
acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.
Part no. 81610, SF/UTP 4x2xAWG 24/1 PVC (S-FTP) 81609, SF/UTP 4x2xAWG 24/1 FRNC (S-FTP)
Dimensions and specifications may be changed without prior notice.
662
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 5e 200
SF/UTP duplex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 200 MHz
Loop resistance: 185 Ohm/km max.
Mutual capacitance: 48 nF/km nom.
Rel. propagation velocity: 74 %
Typical values
Frequency (MHz) 10 16 62,5 100 200
Attenuation (dB/100m) 5,6 7,2 14,4 18,2 25,9
Next (db) 62,0 59,0 50,0 46,0 40,0
ACR (db) 56,4 51,8 35,6 27,8 14,6
Technical data
Weight: app. 100 kg/km
bending radius, repeated: 52 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,96 MJ/m
Copper weight: 56,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
R
Application
HELUKAT200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s, or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.
663
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 5e 200
SF/UTP flex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 200 MHz
Loop resistance: 300 Ohm/km max.
Mutual capacitance: 47 nF/km nom.
Rel. propagation velocity: 69 %
Typical values
Frequency (MHz) 10 16 62,5 100 200
Attenuation (dB/10m) 0,8 1,1 2,4 2,9 4,3
Next (db) 58,0 56,0 45,0 43,0 37,0
ACR (db) 57,2 54,9 42,6 40,1 32,7
Technical data
Weight: app. 40 kg/km
bending radius, repeated: 46 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,543 MJ/m
Copper weight: 24,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT200 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI,
token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT200 series can be manufactured quickly and
easily with all common RJ45 plugs.
664
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 6 300
U/FTP, UL
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 300 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 45 nF/km nom.
Rel. propagation velocity: 77 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300
Attenuation (db/10m) 0,9 1,1 2,2 2,7 3,9 4,7
Next (db) 90,0 88,0 83,0 80,0 76,0 73,0
ACR (db) 89,1 86,9 80,8 77,3 72,1 68,3
Technical data
Weight: app. 37 kg/km
bending radius, repeated: 48 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,41 MJ/m
Copper weight: 20,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, CMX 444
Application R
HELUKAT300 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI,
token ring 4/16 Mbit/s, or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT300 series can be manufactured quickly and
easily with all common RJ45 plugs. This type is certified according UL because of the special PVC jacket.
665
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 6 450
F/FTP
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 450 MHz
Loop resistance: 165 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 450
Attenuation (dB/100m) 5,4 7,0 13,8 17,6 26,0 34,0 38,5
Next (db) 100,0 100,0 95,8 94,5 91,0 87,0 84,3
ACR (db) 94,6 93,0 82,0 76,9 65,0 53,0 45,8
Technical data
Weight: app. 50 kg/km
bending radius, repeated: 59 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,57 MJ/m
Copper weight: 24,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT450 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.
666
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 6 450
F/FTP duplex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 450 MHz
Loop resistance: 165 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 450
Attenuation (dB/100m) 5,4 7,0 13,8 17,6 26,0 34,0 38,5
Next (db) 100,0 100,0 95,8 94,5 91,0 87,0 84,3
ACR (db) 94,6 93,0 82,0 76,9 65,0 53,0 45,8
Technical data
Weight: app. 100 kg/km
bending radius, repeated: 59 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,14 MJ/m
Copper weight: 48,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT450 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
R
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.
667
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 6A 500
F/FTP
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 500 MHz
Loop resistance: 160 Ohm/km max.
Mutual capacitance: 45 nF/km nom.
Rel. propagation velocity: 80 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 250 300 500
Attenuation (db/100m) 5,7 7,2 14,2 18,1 25,8 29,0 31,9 41,8
Next (db) 100,0 100,0 100,0 97,4 92,9 91,4 90,2 86,9
ACR (db) 94,3 92,8 85,8 79,3 67,1 62,4 58,3 45,1
Technical data
Weight: app. 50 kg/km
bending radius, repeated: 100 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,55 MJ/m
Copper weight: 26,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT 500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight
cable channels and platforms due to their optimized construction.
668
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Kategorie 6A 500
F/FTP duplex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 500 MHz
Loop resistance: 160 Ohm/km max.
Mutual capacitance: 45 nF/km nom.
Rel. propagation velocity: 80 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 250 300 500
Attenuation (db/100m) 5,7 7,2 14,2 18,1 25,8 29,0 31,9 41,8
Next (db) 100,0 100,0 100,0 97,4 92,9 91,4 90,2 86,9
ACR (db) 94,3 92,8 85,8 79,3 67,1 62,4 58,3 45,1
Technical data
Weight: app. 100 kg/km
bending radius, repeated: 100 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,13 MJ/m
Copper weight: 52,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT 500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
R
and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight
cable channels and platforms due to their optimized construction.
669
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 6A 500
U/FTP, flex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 500 MHz
Loop resistance: 330 Ohm/km max.
Mutual capacitance: 54 nF/km nom.
Rel. propagation velocity: 78 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 250 500
Attenuation (dB/10m) 0,8 1,1 2,1 2,7 3,9 4,4 6,3
Next (db) 100,0 100,0 100,0 97,0 92,0 91,0 86,0
ACR (db) 99,2 98,9 97,9 94,3 88,1 86,6 79,7
Technical data
Weight: app. 35 kg/km
bending radius, repeated: 49 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,39 MJ/m
Copper weight: 15,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT 500 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet,
ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT500 series can be manufactured
quickly and easily with many common RJ45 plugs.
670
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 7e 600
S/FTP
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 169 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0
Technical data
Weight: app. 60 kg/km
bending radius, repeated: 60 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,60 MJ/m
Copper weight: 28,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
R
Application
HELUKAT600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.
671
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 7e 600
S/FTP duplex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 169 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0
Technical data
Weight: app. 120 kg/km
bending radius, repeated: 60 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,20 MJ/m
Copper weight: 56,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.
672
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 7 600
S/FTP flex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 600 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 45 nF/km nom.
Rel. propagation velocity: 77 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600
Attenuation (dB/10m) 0,8 1,0 2,0 2,6 4,0 4,9 6,3
Next (db) 96,0 96,0 95,0 94,0 88,0 86,0 80,0
ACR (db) 95,2 95,0 93,0 91,4 84,0 81,1 73,7
Technical data
Weight: app. 42 kg/km
bending radius, repeated: 55 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,47 MJ/m
Copper weight: 22,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
R
Application
HELUKAT600 data cables are used in the tertiary level of a network as patch cables and connection cables. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI,
token ring 4/16 Mbit/s or ISDN absolutely trouble-free. With its optimized construction, the HELUKAT600 series can be manufactured quickly and
easily with all common RJ45 plugs.
673
Data, Network and Bus Technology / HELUKAT Copper data cables
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 160 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0
Technical data
Weight: app. 153 kg/km
bending radius, repeated: 95 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Caloric load, approx. value: 2,62 MJ/m
Copper weight: 32,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e, Flame-retardant acc.
to IEC 60332-1
Application
HELUKAT 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT 600A with a double PVC jacket is constructed especially for outdoor applications
like laying at house walls or in cable lines.
674
Data, Network and Bus Technology / HELUKAT Copper data cables
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 150 Ohm/km max.
Mutual capacitance: 42 nF/km nom.
Rel. propagation velocity: 79 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0
Technical data
Weight: app. 102 kg/km
bending radius, repeated: 100 mm
Operating temperature range min.: -45C
Operating temperature range max.: +65C
Caloric load, approx. value: 1,40 MJ/m
Copper weight: 32,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e, Flame-retardant acc.
to IEC 60332-1, Smoke density acc. to IEC 61034
R
Application
HELUKAT 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT 600E with a cold resistant PVC jacket is constructed especially for outdoor
applications like laying at house walls or direct burial.
675
Data, Network and Bus Technology / HELUKAT Copper data cables
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 150 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0
Technical data
Weight: app. 155 kg/km
bending radius, repeated: 330 mm
Operating temperature range min.: -45C
Operating temperature range max.: +70C
Caloric load, approx. value: 2,30 MJ/m
Copper weight: 32,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e
Application
HELUKAT 600 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. The serie of HELUKAT 600AE with a FRNC/PE double jacket and the rodent protection is constructed
especially for outdoor and direct burial applications.
676
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 7A 1200
S/FTP
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 160 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 77 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000 1200
Attenuation (db/100m) 5,2 6,8 13,3 17,3 24,2 30,2 43,5 54,3 56,9 62,9
Next (db) 105,0 105,0 105,0 100,0 95,0 93,0 88,0 85,0 84,0 82,0
ACR (db) 99,8 98,2 91,7 82,7 70,8 62,8 44,5 30,7 27,1 19,1
Technical data
Weight: app. 60 kg/km
bending radius, repeated: 65 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,57 MJ/m
Copper weight: 30,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7A, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
R
Application
HELUKAT1200-7A data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet,
ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.
677
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 7A 1200
S/FTP duplex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 160 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 77 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000 1200
Attenuation (db/100m) 5,2 6,8 13,3 17,3 24,2 30,2 43,5 54,3 56,9 62,9
Next (db) 105,0 105,0 105,0 100,0 95,0 93,0 88,0 85,0 84,0 82,0
ACR (db) 99,8 98,2 91,7 82,7 70,8 62,8 44,5 30,7 27,1 19,1
Technical data
Weight: app. 120 kg/km
bending radius, repeated: 65 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,16 MJ/m
Copper weight: 60,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7A, Flame-retardant acc.
to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to 60754-2, Corrosiveness
acc. to EN50267-2-3
Application
HELUKAT1200-7A data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance
reserves and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet,
ATM155, FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application
in tight cable channels and platforms due to their optimized construction.
678
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 8 1200
S/FTP
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %
Typical values
Frequency (Hz) 10 16 62,5 100 200 300 600 1000 1200
Attenuation (db/100m) 4,9 6,3 12,7 16,3 23,5 29,4 42,8 53,0 59,0
Next (db) 100,0 100,0 95,0 93,0 90,0 87,0 81,0 78,0 77,0
ACR (db) 95,1 93,7 82,3 76,7 66,5 57,6 38,2 25,0 18,0
Technical data
Weight: app. 66 kg/km
bending radius, repeated: 72 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,70 MJ/m
Copper weight: 40,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 8 (draft),
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3
R
Application
HELUKAT1200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.
679
Data, Network and Bus Technology / HELUKAT Copper data cables
LAN Cable
Category 8 1200
S/FTP duplex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Rel. propagation velocity: 79 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 1000 1200
Attenuation (db/100m) 4,9 6,3 12,7 16,3 23,5 29,4 42,8 53,0 59,0
Next (db) 100,0 100,0 95,0 93,0 90,0 87,0 81,0 78,0 77,0
ACR (db) 95,1 93,7 82,3 76,7 66,5 57,6 38,2 25,0 18,0
Technical data
Weight: app. 133 kg/km
bending radius, repeated: 72 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,50 MJ/m
Copper weight: 80,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 8 (draft),
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3
Application
HELUKAT1200 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, token ring
4/16 Mbit/s or ISDN absolutely trouble-free. Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels
and platforms due to their optimized construction.
680
Data, Network and Bus Technology / HELUKAT Copper data cables
Multimedia Cable
Category 8 1500
S/FTP
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 42 nF/km nom.
Rel. propagation velocity: 77 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 1000 1200 1500
Attenuation (db/100m) 4,2 6,3 12,7 16,5 21,5 27,5 41,7 54,4 59,8 66,2
Next (db) 110,0 110,0 110,0 110,0 110,0 105,0 95,0 85,0 80,0 74,0
ACR (db) 105,8 103,7 97,3 93,5 88,5 77,5 53,3 30,6 22,2 7,8
Technical data
Weight: app. 66 kg/km
bending radius, repeated: 68 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,74 MJ/m
Copper weight: 41,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 8 (draft),
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3
R
Application
HELUKAT 1500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. That means applications such as multimedia (TV, Video, Data, Speach) are no problem
for this series.Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels and platforms due to their optimized
construction.
681
Data, Network and Bus Technology / HELUKAT Copper data cables
Multimedia Cable
Category 8 1500
S/FTP duplex
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1200 MHz
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 42 nF/km nom.
Rel. propagation velocity: 77 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 1000 1200 1500
Attenuation (db/100m) 4,2 6,3 12,7 16,5 21,5 27,5 41,7 54,4 59,8 66,2
Next (db) 110,0 110,0 110,0 110,0 110,0 105,0 95,0 85,0 80,0 74,0
ACR (db) 105,8 103,7 97,3 93,5 88,5 77,5 53,3 30,6 22,2 7,8
Technical data
Weight: app. 135 kg/km
bending radius, repeated: 68 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,50 MJ/m
Copper weight: 82,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 8 (draft),
Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034, Halogen-free acc. to
60754-2, Corrosiveness acc. to EN50267-2-3
Application
HELUKAT1500 data cables are used in the tertiary, but also in the secondary level of a network. They are characterized by large performance reserves
and outstanding performance. They can be used to implement services such as 10Gigabit Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155,
FDDI, token ring 4/16 Mbit/s or ISDN absolutely trouble-free. That means applications such as multimedia (TV, Video, Data, Speach) are no problem
for this series.Likewise, the mechanical characteristics are perfectly suited for the application in tight cable channels and platforms due to their optimized
construction.
682
Data, Network and Bus Technology / HELUKAT Copper data cables
Electrical data
Characteristic impedance: 150 Ohm
15 ohm at 3 to 20 MHz
185 Ohm
18.5 ohm at 38.4 kHz
270 Ohm
27 ohm at 9.6 kHz
Direct current resistance: 57,1 Ohm/km
Rel. propagation velocity: 78 %
Typical values
Frequency (MHz) 20 100 20 100 20 100
Attenuation (dB/100m) 7,4 18,7 4,9 12,3 7,4 18,7
Next (db) 80,0 60,0 50,0 39,0 60,0 49,0
Technical data
Weight: app. 85 kg/km
bending radius, repeated: 110 mm
Operating temperature range min.: -10C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,70 MJ/m
Copper weight: 38,00 kg/km
Application
HELUKABEL IVS types are used in the area of the IVS system, developed by IBM. They correspond to the wiring guidelines set by IBM.
683
684
BUS CABLES
Industrial Ethernet HELUKAT 100S ECO SF/UTP 4-core, drag chain 694
Industrial Ethernet HELUKAT 100S ECO SF/UTP 4 pairs, drag chain 695
Profibus PA 714
685
BUS CABLES
Interbus fixed installation, remote bus and installation remote bus 742
Interbus drag chain, remote bus and installation remote bus 744
686
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
ROBUST 600IND
S/FTP, Category 7e
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 1000 MHz
Loop resistance: 148 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Relative propagation velocity: 78 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 600 900 1000
Attenuation (dB/100m) 5,6 7,1 13,9 17,5 25,2 32,1 44,9 55,0 58,0
Next (db) 100,0 100,0 96,0 94,0 88,0 84,0 73,0 71,0 69,0
ACR (db) 94,4 92,9 82,1 76,5 62,8 51,9 28,1 16,0 9,0
Technical data
Weight: app. 62 kg/km
bending radius, repeated: 85 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,74 MJ/m
Copper weight: 34,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7e, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3, Oil-resistant
Application
HELUKAT 600IND Cat 7e Robust is used for harsh industrial environments. Mechanically, this product exhibits excellent resistance to mineral oils, R
greases and cooling lubricants and has good microbe and hydrolysis resistance. Electrically, this cable is characterized by^high reserve capacity and
outstanding performance. This allows you to create services such as Gigabit Ethernet, Fast Ethernet, Ethernet, ATM155, FDDI, Token Ring 4/16
Mbit/s or ISDN without difficulty. These cable considerably exceed the requirement for compliance with Class B interference emission to EN55022,
as well as interference immunity to EN55024. This gives the series outstanding EMC characteristics.
687
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
SHIPLINE 600IND
S/FTP, Category 7
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 600 MHz
Loop resistance: 168 Ohm/km max.
Mutual capacitance: 43 nF/km nom.
Relative propagation velocity: 72 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 600
Attenuation (dB/10m) 0,7 0,8 1,6 2,1 3,1 5,2
Next (db) 90,0 90,0 85,0 81,0 76,0 68,0
ACR (db) 89,3 89,2 83,4 78,9 72,9 62,8
Technical data
Weight: app. 85 kg/km
bending radius, repeated: 85 mm
Operating temperature range min.: -20C
Operating temperature range max.: +75C
Caloric load, approx. value: 0,80 MJ/m
Copper weight: 36,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc. to IEC 60332-3, Smoke density acc. to IEC 61034,
Halogen-free acc. to 60754-2, Corrosiveness acc. to EN50267-2-3, Oil-resistant
Application
HELUKAT 600IND Cat 7 Shipline is designed specially for use in shipbuilding and exceptionally well-suited for Ethernet applications. It guarantees
excellent transmission characteristics and may be used even under the harshest conditions.The cable listed here is certified by German Lloyd; this
means it is designed for flexible marine and offshore applications.
688
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
ROBUSTFLEX 600IND
S/FTP, Category 7
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 ohm at 101 to 600 MHz
Loop resistance: 290 Ohm/km max.
Mutual capacitance: 42 nF/km nom.
Relative propagation velocity: 64 %
Typical values
Frequency (MHz) 10 16 62,5 100 200 600
Attenuation (db/10m) 0,8 1,1 2,2 2,8 4,0 7,4
Next (db) 80,0 80,0 75,0 72,0 68,0 61,0
ACR (db) 79,2 78,9 72,8 69,2 64,0 53,6
Technical data
Weight: app. 48 kg/km
bending radius, repeated: 64 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,45 MJ/m
Copper weight: 28,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 7, Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034,
Halogen-free acc. to 60754-2, Corrosiveness acc. to EN50267-2-3, Oil-resistant, AWM 20963 (80C/30V)
Application
HELUKAT600IND Cat 7 Robustflex is an Ethernet cable that, thanks to use of a halogen-free PU outer sheath, is ideal for harsh industrial surroundings. R
This cable is configurable with common RJ45 plugs (industrial and office version), as well as with some Sub-D and M12 plugs.
689
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
10GIG 500IND
S/FTP, Category 6A
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 500 MHz
Conductor resistance, max.: 59 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km
Loop resistance: 118 Ohm/km max.
Mutual capacitance: 72 nF/km nom.
Test voltage: 0,7 kV
Relative propagation velocity: 62 %
Typical values
Frequency (MHz) 10 16 62,5 100 250 500
Attenuation (db/100m) 5,9 7,5 15,0 19,1 31,1 45,3
Next (dB) 60,3 57,2 48,4 45,3 39,3 34,3
PSNext (dB) 57,3 54,2 45,4 42,3 36,3 31,8
Technical data
Weight: app. 115 kg/km
bending radius, repeated: 80 mm
Operating temperature range min.: -40C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,69 MJ/m
Copper weight: 44,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6A, Flame-retardant acc. to IEC 60332-3, CMG FT4
Application
HELUKAT 600IND 10GIG was designed specially for extreme industrial applications. The copper data cable is especially well-suited for Category 6A
Ethernet applications up to 10 Gigabits / 500 MHz (IEC61156-5). It guarantees excellent transmission characteristics and may be used even under
the harshest conditions. The cable listed here is based on PROFInet Type A. Thanks to the addtional inner sheath, the cable can be processed using
the quick contact method. This version with PVC jacket is designed specifically for fixed installation under difficult industrial conditions.
690
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
Drag Chain 250S
SF/UTP, Category 6
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm bei 101 bis 250 MHz
Conductor resistance, max.: 140 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km
Loop resistance: 280 Ohm/km max.
Mutual capacitance: 52 nF/km nom.
Test voltage: 0,7 kV
Relative propagation velocity: 67 %
Typical values
Frequency (MHz) 10 16 62,5 100 250
Attentuation (db/10m) 0,9 1,2 2,4 2,9 4,9
Next (db) 59,3 56,2 47,4 44,3 38,3
ACR (db) 58,4 55,0 45,0 41,4 33,4
Technical data
Weight: app. 63 kg/km
bending radius, repeated: 60 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,35 MJ/m
Copper weight: 34,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 6, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
CMX 75C (shielded) R
Application
HELUKAT 250S trailing cable Cat 6 is designed for use in cable carriers and the recurring loads caused by moving machine components and provides
excellent transmission characteristics under extremely difficult conditions.
691
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
ROBUSTFLEX 200IND
SF/UTP, Category 5e
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
100 Ohm 20 Ohm at 101 to 200 MHz
Loop resistance: 260 Ohm/km max.
Mutual capacitance: 47 nF/km nom.
Relative propagation velocity: 74 %
Typical values
Frequency (MHz) 10 16 62,5 100 200
Attenuation (dB/10m) 0,8 1,1 2,4 2,9 4,3
Next (db) 58,0 56,0 45,0 43,0 37,0
ACR (db) 57,2 54,9 42,6 40,1 32,7
Technical data
Weight: app. 44 kg/km
bending radius, repeated: 46 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,54 MJ/m
Copper weight: 24,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc. to IEC 60332-1, Smoke density acc. to
IEC 61034, Halogen-free acc. to 60754-2, Oil-resistant
Application
HELUKAT 200IND Cat 5e Robustflex is used in harsh industrial surroundings and characterized by high reserve capacity and outstanding performance.
Mechanically, the halogen-free PU outer sheath makes it ideal for harsh industrial surroundings. This cable is configurable with common RJ45 plugs
(industrial and office version), as well as with various Sub-D and M12 plugs.
692
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
WK Industrial 105C 100IND
SF/UTP, Category 5e
Type Windenergy
Cable structure SF/UTP 2x2x0,75 mm (stranded)
Inner conductor diameter: Copper, tinned (AWG 22/7)
Core insulation: XLPE ray cross-linking
Core colours: wh, ye, bu, og
Stranding element: Star quad
Shielding 1: Polyester foil over stranded bundle
Shielding 2: Polyester foil, aluminium-lined
Total shielding: Cu braid, tinned
Outer sheath material: X-FRNC
Cable external diameter: app. 6,5 mm 0,2 mm
Outer sheath colour: Black similar to RAL 9005
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 60 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 52 nF/km nom.
Test voltage: 2 kV
Relative propagation velocity: 69 %
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 6,3 8,0 16,5 21,3
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 63,7 57,0 38,5 28,7
Technical data
Weight: app. 64 kg/km
bending radius, repeated: 52 mm
Operating temperature range min.: -40C
Operating temperature range max.: +105C *
Caloric load, approx. value: 0,89 MJ/m
Copper weight: 34,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Category 5, Flame-retardant acc. to IEC 60332-3, Halogen-free acc. to 60754-2, Corrosiveness acc. to
EN50267-2-3, UL-Syle 21281 80C/300V
Application R
HELUKAT 100IND Cat 5e WK Industrial 105C is designed specially for demanding temperature requirements such as those encountered in wind
turbines. Radiation cross-linking provides improved thermal stability as well good oil resitance.
693
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
DRAG CHAIN ECO 100S
SF/UTP 4 core, Category 5e
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 250 Ohm/km max.
Mutual capacitance: 51 nF/km nom.
Test voltage: 0,5 kV
Relative propagation velocity: 67 %
Typical values
Frequency (MHz) 10 16 62,5 100 155
Attentuation (db/100m) 9,5 12,1 24,8 32,0 41,0
Next (db) 50,0 48,0 38,5 35,3 30,0
Technical data
Weight: app. 30 kg/km
bending radius, repeated: 70 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,37 MJ/m
Copper weight: 17,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3, AWM 20963 (80C/30V)
Application
HELUKAT 100S Cat 5e drag chain Eco is designed in use in cable carriers and the recurring loads cause by moving machine components. Thanks to
the PU sheath, it also offers excellent resistance to common mineral oils, greases and cooling lubricants.
694
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
Drag chain ECO 100S
SF/UTP 4-pair, Category 5e
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 250 Ohm/km max.
Mutual capacitance: 48 nF/km nom.
Test voltage: 0,5 kV
Relative propagation velocity: 67 %
Typical values
Frequency (MHz) 10 16 62,5 100 155
Attentuation (db/100m) 9,5 12,1 24,8 32,0 41,0
Next (db) 50,0 48,0 38,5 35,3 30,0
Technical data
Weight: app. 56 kg/km
bending radius, repeated: 102 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,64 MJ/m
Copper weight: 31,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5e, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Corrosiveness acc. to EN50267-2-3, AWM 20963 (80C/30V)
Application
HELUKAT 100S Cat 5e drag chain Eco is designed for use in cable carriers and the recurring loads caused by moving machine components. Thanks
to the PU sheath, it also offers excellent resistance to common mineral oils, greases and cooling lubricants. R
Part no. 82839, INDUSTRIAL ETHERNET CAT.5e
Dimensions and specifications may be changed without prior notice.
695
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
DRAG CHAIN 200S
SF/UTP 4 core, Category 5
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 156 Ohm/km max.
Mutual capacitance: 51 nF/km nom.
Relative propagation velocity: 67 %
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/10m) 1,0 1,2 2,6 3,3
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 46,0 42,8 32,4 28,7
Technical data
Weight: app. 54 kg/km
bending radius, repeated: 75 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Caloric load, approx. value: 0,944 MJ/m
Copper weight: 30,00 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Oil-resistant
Application
HELUKAT 200S Cat 5 drag chain is designed for use in cable carriers and the extreme loads caused by moving machine components and provides
excellent transmission characteristics under the most difficult and extreme conditions. Thanks to the clever structure, it is also suitable mechanically
for use even in cable carriers with a high packing density. This cable configurable with conventional Sub-D plugs, as well as with various RJ45 plugs.
696
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
DRAG CHAIN 200S
SF/UTP 4 pair, Category 5
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 156 Ohm/km max.
Mutual capacitance: 51 nF/km nom.
Relative propagation velocity: 67 %
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/10m) 1,0 1,2 2,6 3,3
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 46,0 42,8 32,4 28,7
Technical data
Weight: app. 110 kg/km
bending radius, repeated: 115 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Caloric load, approx. value: 2,08 MJ/m
Copper weight: 54,30 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc. to IEC 60332-1, Halogen-free acc. to 60754-2,
Oil-resistant
Application
HELUKAT 200S Cat 5 drag chain is designed for use in cable carriers and the extreme loads caused by moving machine components and provides
excellent transmission characteristics under the most difficult and extreme conditions. Thanks to the clever structure, it is also suitable mechanically R
for use even in cable carriers with a high packing density. This cable is configurable with conventional Sub-D plugs, as well as with various RJ45 plugs.
697
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
TORDIERFLEX 100T
SF/UTP, Category 5
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Loop resistance: 260 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Relative propagation velocity: 68 %
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/10m) 1,3 1,6 3,2 4,0
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 45,7 42,4 31,8 28,0
Technical data
Weight: app. 63 kg/km
bending radius, repeated: 56 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 1,234 MJ/m
Copper weight: 29,50 kg/km
Norms
Acc. to ISO/IEC 11801, Acc. to EN 50173, Acc. to EIA/TIA 568-A, Category 5, Flame-retardant acc. to IEC 60332-1, Smoke density acc. to IEC 61034,
Halogen-free acc. to 60754-2, Oil-resistant, AWM Style 20236 80C/30V
Application
HELUKAT 100T Cat 5 Torsionflex is designed for applications with torsion loads, e.g. in robots, and characterized by high reserve capacity and
outstanding performance, even after exposure to extreme conditions. Thanks to the clever structure, it is also possible to achieve a long service life
mechanically. These cables are configurable with conventional Sub-D plugs, as well as with various RJ45 plugs.
698
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
PROFInet Type A
fixed installed + robust
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 62 Ohm/km 62 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km 0,5 GOhm x km
Loop resistance: 115 Ohm/km max. 115 Ohm/km max.
Mutual capacitance: 50 nF/km nom. 50 nF/km nom.
Test voltage: 2 kV 2 kV
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 5,2 6,9 15,0 19,5
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 64,8 58,1 40,0 30,5
Technical data
Weight: app. 67 kg/km app. 64 kg/km
bending radius, repeated: 65 mm 65 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +70C
Caloric load, approx. value: 0,34 MJ/m 0,91 MJ/m
Copper weight: 32,00 kg/km 32,00 kg/km
Norms
Applicable standards: PROFInet Guideline PROFInet Guideline
Acc. to ISO/IEC 11801 Acc. to ISO/IEC 11801
Acc. to EN 50173
Category 5e
Acc. to EN 50173
Category 5e R
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: CMG 75C PLTC FT4 -
CSA standard: CSA FT 4 -
Application
HELUKAT PROFInet Type A Cat 5e for fixed installation in industrial networks, rugged. It guarantees excellent transmission characteristics and may
be used even under the harshest conditions. The cable listed here corresponds to PROFInet Type A; this means the version with PVC sheath is designed
for normal fixed installations and the version with PU sheath is for difficult fixed installations in harsh industrial environments.
Part no. 800653, PROFInet type A (SK) 801194, PROFInet type A (SK)
Dimensions and specifications may be changed without prior notice.
699
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
PROFInet Type A
radiation resistant + armoured
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 62 Ohm/km 62 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km 0,5 GOhm x km
Loop resistance: 124 Ohm/km max. 115 Ohm/km max.
Mutual capacitance: 50 nF/km nom. 50 nF/km nom.
Test voltage: 2 kV 2 kV
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 5,2 6,9 15,0 19,5
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 64,8 58,1 40,0 30,5
Technical data
Weight: app. 63 kg/km app. 124 kg/km
bending radius, repeated: 100 mm 100 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +70C
Caloric load, approx. value: 0,29 MJ/m 2,14 MJ/m
Copper weight: 32,00 kg/km 31,00 kg/km
Norms
Applicable standards: PROFInet Guideline PROFInet Guideline
Acc. to ISO/IEC 11801 Acc. to ISO/IEC 11801
Acc. to EN 50173 Acc. to EN 50173
Category 5e Category 5e
Application
HELUKAT PROFInet Type A Cat 5e is radiation-resistant + armoured for fixed installation in industrial networks. It guarantees excellent transmission
characteristics and may be used even under the harshest conditions. The cables listed here correspond to PROFInet Type A and thanks to their special
construction with cross-linked PVC-inner sheath/PU outer sheath are well-suited for fixed applications inside irradiated areas, while the armoured
type with PVC inner sheath/PE outer sheath is ideal for areas with rodent problems.
Part no. 801195, PROFInet type A (SK) 801650, PROFInet type A (SK)
Dimensions and specifications may be changed without prior notice.
700
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
PROFInet Type B
hybrid
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 60 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km
Loop resistance: 120 Ohm/km max.
Mutual capacitance: 52 nF/km nom.
Test voltage: 2 kV
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 6,3 8,0 16,5 21,3
Next (db) 50,0 47,0 38,0 35,0
ACR (db) 43,7 39,0 21,5 13,7
Technical data
Weight: app. 153 kg/km
bending radius, repeated: 103 mm
Operating temperature range min.: -40C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,50 MJ/m
Copper weight: 94,00 kg/km
Norms
Applicable standards: PROFInet Guideline
Acc. to ISO/IEC 11801 R
Acc. to EN 50173
Category 5e
Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
Corrosiveness acc. to EN50267-2-3
Low-smoke acc. to EN50268-2
UL Style: UL Style 21282
Application
HELUKAT PROFInet Type B Cat 5e hybrid for flexible applications. The cable listed here corresponds to PROFInet Type B with integrated power supply
in a cable with halogen-free and flame-retardent construction.
701
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
PROFInet Typ B
SHIPLINE + FESTOON
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz 100 Ohm 5 %
Conductor resistance, max.: 60 Ohm/km 60 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km 0,5 GOhm x km
Loop resistance: 120 Ohm/km max. 120 Ohm/km max.
Mutual capacitance: 52 nF/km nom. 52 nF/km nom.
Test voltage: 2 kV 2 kV
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 6,0 7,6 16,0 21,0
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 64,0 57,4 39,0 29,0
Technical data
Weight: app. 68 kg/km app. 68 kg/km
bending radius, repeated: 50 mm 70 mm
Operating temperature range min.: -40C -10C
Operating temperature range max.: +70C +80C
Caloric load, approx. value: 0,45 MJ/m 1,20 MJ/m
Copper weight: 32,00 kg/km 32,00 kg/km
Norms
Applicable standards: PROFInet Guideline PROFInet Guideline
Acc. to ISO/IEC 11801 Acc. to ISO/IEC 11801
Acc. to EN 50173 Acc. to EN 50173
Category 5e Category 5e
Halogen-free acc. to 60754-2 Flame-retardant acc. to IEC 60332-3
Flame-retardant acc. to IEC 60332-3
Corrosiveness acc. to EN50267-2-3
Low-smoke acc. to EN50268-2
UL Style: CMG 75C PLTC FT4 CMG 75C or PLTC or AWM 21694 600V
CSA standard: CSA FT 4 CSA FT 4
Application
HELUKAT PROFInet Type B Cat 5e SHIPLINE + FESTOON designed specially for marine/offshore applications as well as FESTOON applications. The
SHIPLINE version is certified by the Germanische Lloyd and suitable for flexible marine and offshore applications.
Part no. 802185, PROFInet type B (SK) 803295, PROFInet type B (SK)
Dimensions and specifications may be changed without prior notice.
702
Data, Network and Bus Technology / HELUKABEL BUS-Cables
Industrial Ethernet
PROFInet Type B + C
flexible + high flexible
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 62 Ohm/km 60 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km 0,5 GOhm x km
Loop resistance: 115 Ohm/km max. 115 Ohm/km max.
Mutual capacitance: 52 nF/km nom. 52 nF/km nom.
Test voltage: 2 kV 0,7 kV
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (dB/100m) 6,0 7,6 16,0 21,0
Next (db) 70,0 65,0 55,0 50,0
ACR (db) 64,0 57,4 39,0 29,0
Technical data
Weight: app. 67 kg/km app. 61 kg/km
bending radius, repeated: 100 mm 55 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,32 MJ/m 0,85 MJ/m
Copper weight: 32,00 kg/km 32,00 kg/km
Norms
Applicable standards: PROFInet Guideline PROFInet Guideline
Acc. to ISO/IEC 11801 Acc. to ISO/IEC 11801
Acc. to EN 50173
Category 5e
Acc. to EN 50173
Category 5e R
Flame-retardant acc. to IEC 60332-1 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
UL Style: CMG 75C PLTC FT4 CMX 75C (shielded)
CSA standard: CSA FT 4 -
Application
HELUKAT PROFInet Type B (flexible) + Type C (highly flexible) Cat 5e for use on moving parts and in cable carriers. The cables listed here correspond
to the PROFInet classifications Type B and Type C for moving cables and are designed to withstand mechanical loads.
Part no. 800654, PROFInet type B (SK) 800655, PROFInet type C (SK)
Dimensions and specifications may be changed without prior notice.
703
Industrial Ethernet
HELUKAT PROFInet Torsion Typ C (SK) 2x2xAWG22/19 PUR
Electrical data
Characteristicimpedance: 100Ohm 15Ohmat1to100MHz
Conductorresistance,max.: 60Ohm/km
Insulationresistance,min.: 0,5GOhmxkm
Loopresistance: 120Ohm/kmmax.
Mutualcapacitance: 52nF/kmnom.
Testvoltage: 0,7kV
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (db/100m) 7,6 10,0 26,5 41,0
ELFEXT (db) 43,8 39,7 24,0 20,0
Technical data
Weight: app.54kg/km
bendingradius,repeated: 70mm
Operatingtemperaturerangemin.: -40C
Operatingtemperaturerangemax.: +80C
Caloricload,approx.value: 0,45MJ/m
Copperweight: 32,00kg/km
Norms
Applicablestandards: PROFInetGuideline+IEC61158-2
Category5e
Halogen-freeacc.to60754-1
Flame-retardantacc.toIEC60332-1-2
ULStyle: AWMStyle2116180C
Application
HELUKAT PROFInetTypeCCategory5eTORSIONoffersexcellenttransmissioncharacteristicsandisdesignedforapplicationswithtorsionloads,
24.02.2016/Dimensionsandspecificationsmaybechangedwithoutpriornotice.
e.g.inrobots.ThecablelistedherecorrespondstothePROFInetTypeCclassificationforcontinousmovement.
BUS Cables
Profibus L2
Indoor
Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 30 nF/km nom. 30 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 2,5 dB/km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/km 38,4 kHz < 4,0 dB/km
4 MHz < 22,0 dB/km 4 MHz < 22,0 dB/km
16 MHz < 42,0 dB/km 16 MHz < 42,0 dB/km
Technical data
Weight: app. 69 kg/km app. 69 kg/km
bending radius, repeated: 120 mm 120 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,99 MJ/m 0,99 MJ/m
Copper weight: 24,00 kg/km 24,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: CMX 75C (shielded) CMX 75C (shielded)
CSA standard: CSA FT1 CSA FT1
Application
HELUKABEL Profibus L2 Indoor is designed for fixed indoor installation in Profibus industrial networks. Depending on the application, the colour grey R
(special colour) or violet (standard colour) is availiable. Otherwise, the technical characteristics of the two products are identical.
705
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
PROFIBUS L2 Outdoor + Industry
Outdoor + Industry
Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 30 nF/km nom. 30 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 2,5 dB/km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/km 38,4 kHz < 4,0 dB/km
4 MHz < 22,0 dB/km 4 MHz < 22,0 dB/km
16 MHz < 42,0 dB/km 16 MHz < 42,0 dB/km
Technical data
Weight: app. 64 kg/km app. 67 kg/km
bending radius, repeated: 120 mm 120 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 2,26 MJ/m 1,52 MJ/m
Copper weight: 24,00 kg/km 24,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
Application
HELUKABEL Profibus L2 Outdoor + Industry are special cables for use in Profibus industrial networks. The Outdoor version is designed for use in
open-air environments, i.e. can withstand wind, weather and sun (not for burial direcly in the ground). The Industry version is used in fixed installation
applications in harsh industrial environment. Mechanically, this product exhibits excellent resistance to mineral oils, greases and cooling lubricants
and has good microbe and hydrolysis resistance.
706
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus L2 direct Burial
without + with Armouring
Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 5 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 30 nF/km nom. 30 nF/km nom.
Nominal voltage: - 250 V
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 2,5 dB/km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/km 38,4 kHz < 4,0 dB/km
3 MHz < 22,0 dB/km 4 MHz < 22,0 dB/km
20 MHz < 42,0 dB/km 16 MHz < 42,0 dB/km
Technical data
Weight: app. 92 kg/km app. 132 kg/km
bending radius, repeated: 150 mm 165 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 2,657 MJ/m 2,40 MJ/m
Copper weight: 24,00 kg/km 24,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Application
HELUKABEL Profibus L2 Direct Burial cables without + with armouring are special cables in the Profibus industrial networks. The version without R
armouring is for normal an direct cable burial in the ground. The version with steel tape armouring offers additional protection against rodents and is
the right choice for regions with such animals.
707
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus L2
7-wire
Electrical data
Characteristic impedance: 150 Ohm 10 %
Conductor resistance, max.: 86,7 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 173 Ohm/km max.
Mutual capacitance: 30 nF/km nom.
Test voltage: 1,5 kV
Attenuation: 9,6 kHz < 3,0 dB/km
38,4 kHz < 5,0 dB/km
4 MHz < 26,0 dB/km
16 MHz < 55,0 dB/km
Technical data
Weight: app. 75 kg/km
bending radius, repeated: 80 mm
Operating temperature range min.: -20C
Operating temperature range max.: +80C
Caloric load, approx. value: 1,20 MJ/m
Copper weight: 24,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571
Application
HELUKABEL Profibus L2 7-wire for mobile applications in Profibus industrial networks. With its core design and the special PVC sheath, the type
described here is suitable for normal mobile applications.
708
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus L2
Drag Chain
Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 80 Ohm/km 80 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 160 Ohm/km max. 160 Ohm/km max.
Mutual capacitance: 30 nF/km nom. 30 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 3,0 dB/km 9,6 kHz < 3,0 dB/km
38,4 kHz < 5,0 dB/km 38,4 kHz < 5,0 dB/km
4 MHz < 25,0 dB/km 4 MHz < 25,0 dB/km
16 MHz < 52,0 dB/km 16 MHz < 52,0 dB/km
Technical data
Weight: app. 65 kg/km app. 65 kg/km
bending radius, repeated: 63 mm 63 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,52 MJ/m 1,52 MJ/m
Copper weight: 25,00 kg/km 25,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
Application
This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the cell and field area. For the information
exchange between different automation systems as well as for communication with the connected decentralized field units, serial field bus systems R
are used. The above mentioned types are suitable for drag chains (stranded).
709
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus
ET200X + ECOFAST
Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 15 %
Conductor resistance, max.: 73 Ohm/km 73 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 145 Ohm/km max. 145 Ohm/km max.
Mutual capacitance: 30 nF/km nom. 30 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Relative propagation velocity: - 81 %
Attenuation: 9,6 kHz < 3,0 dB/Km 9,6 kHz 3,0 dB/km
38,4 kHz < 5,0 dB/Km 38,4 kHz 5,0 dB/km
4 MHz < 25,0 dB/Km 4 MHz 30,0 dB/km
16 MHz < 52,0 dB/Km 16 MHz 60,0 dB/km
Technical data
Weight: app. 105 kg/km app. 159 kg/km
bending radius, repeated: 140 mm 165 mm
Operating temperature range min.: -5C -15C
Operating temperature range max.: +60C +60C
Caloric load, approx. value: 1,973 MJ/m 2,835 MJ/m
Copper weight: 46,00 kg/km 90,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
UL Style: AWM Style 20236 AWM I/II A/B 80C 30V UL Style 20233
FT1
Application
HELUKABEL Profibus ET200X + Ecofast Hybrid cables are designed for continuous motion in cable carriers. The hybrid construction integrates the
power supply next to the Profibus in one cable. The type ET200X offers three 0,75mm power conductors, while the type Ecofast 4 has 1,5mm power
conductors and greater current-carrying capacity.
710
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus
SHIPLINE and High Temperature
Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1,6 GOhm x km 1,6 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 29 nF/km nom. 28 nF/km nom.
Nominal voltage: 60 V 250 V
Test voltage: 1 kV 3,6 kV
Attenuation: 9,6 kHz < 2,5 dB/Km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/Km 38,4 kHz < 4,0 dB/km
4 MHz < 22,0 dB/Km 4 MHz < 22,0 dB/km
16 MHz < 42,0 dB/Km 16 MHz < 42,0 dB/km
Technical data
Weight: app. 84 kg/km app. 64 kg/km
bending radius, repeated: 80 mm 52 mm
Operating temperature range min.: -25C -50C
Operating temperature range max.: +80C +180C
Caloric load, approx. value: 1,26 MJ/m 0,30 MJ/m
Copper weight: 35,00 kg/km 24,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Flame-retardant acc. to IEC 60332-3
Flame-retardant acc. to IEC 60332-1
Application R
HELUKABEL Profibus Shipline is designed for marine/offshore applications and certified by German Lloyd. Thanks to use of stranded conductors,
this cable can be moved occasionally. The High-Temperature version is used in fixed installations with demanding temperature requirements, e.g. in
the vicinity of a hot furnace or near welding activities.
711
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
DESINA-HYBRID-BUS
hybrid
Electrical data
Conductor resistance, max.: 13,7 Ohm/km
Insulation resistance, min.: 0,5 GOhm x km
Test voltage: 3 kV
Optical characteristic
Fibre attenuation: 230 dB/km max. at 650 nm
Technical data
Weight: app. 120 kg/km
bending radius, repeated: 130 mm
Operating temperature range min.: -20C
Operating temperature range max.: +80C
Copper weight: 60,00 kg/km
Norms
Applicable standards: Detail specification for DESINA
Application
HELUKABEL DESINA-Hybrid-Bus is used for mobile applications in machinery. Use of a PU sheath provides excellent resistance to common mineral
oils, greases and cooling lubricants in industrial automation.
712
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus L2
TORSION + FESTOON
Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 49 Ohm/km 66,5 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1,6 GOhm x km
Loop resistance: 98 Ohm/km max. 133 Ohm/km max.
Mutual capacitance: 29 nF/km nom. 28 nF/km nom.
Test voltage: 3,6 kV 2 kV
Relative propagation velocity: - 81 %
Attenuation: 9,6 kHz < 3,0 dB/km 9,6 kHz 3,0 dB/km
38,4 kHz < 5,0 dB/km 38,4 kHz 4,0 dB/km
4 MHz < 25,0 dB/km 4 MHz 25,0 dB/km
16 MHz < 51,0 dB/km 16 MHz 49,0 dB/km
Technical data
Weight: app. 66 kg/km app. 64 kg/km
bending radius, repeated: 100 mm 70 mm
Operating temperature range min.: -25C -40C
Operating temperature range max.: +75C +60C
Caloric load, approx. value: 0,89 MJ/m 1,09 MJ/m
Copper weight: 32,00 kg/km 23,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Flame-retardant acc. to EN 50265-2-1
Flame-retardant acc. to IEC 60332-1
UL Style: CMX 75C (shielded) CMG 75C or CL2 or AWM 20201 600V
CSA standard: - CSA FT 4
R
Application
HELUKABEL Profibus Torsion is used in mobile applications in robots. The special torsion construction allows this cable to be twisted (torsioned) and
is halogen-free thanks to use PU sheath. The Festoon version is used for hanging/moving loads in garland applications.
713
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus PA
Electrical data
Characteristic impedance: 100 Ohm 20 % 100 Ohm 20 %
Conductor resistance, max.: 22 Ohm/km 22 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 44 Ohm/km max. 44 Ohm/km max.
Mutual capacitance: 60 nF/km nom. 60 nF/km nom.
Nominal voltage: 300 V 300 V
Test voltage: 2,5 kV 2,5 kV
Attenuation: 39 kHz 3,0 dB/km 39 kHz 3,0 dB/km
Technical data
Weight: app. 76 kg/km app. 76 kg/km
bending radius, repeated: 140 mm 140 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 0,95 MJ/m 0,95 MJ/m
Copper weight: 44,00 kg/km 44,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571 UL Style 2571
Application
HELUKABEL Profibus PA is used for normal requirements in the process automation field (chemical industry). The colour blue identifies it as suitable
for use in potentially explosive areas (and ATEX/ Class II, EX-i/ EN 60079-14). For other applications, the colour black is usually selected.
714
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus PA
armoured
Electrical data
Characteristic impedance: 100 Ohm 15 % 100 Ohm 15 %
Conductor resistance, max.: 22 Ohm/km 22 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 44 Ohm/km max. 44 Ohm/km max.
Mutual capacitance: 55 nF/km nom. 55 nF/km nom.
Nominal voltage: 300 V 300 V
Test voltage: 2,5 kV 2,5 kV
Attenuation: 39 kHz 3,0 dB/km 39 kHz 3,0 dB/km
Technical data
Weight: app. 170 kg/km app. 170 kg/km
bending radius, repeated: 140 mm 200 mm
Operating temperature range min.: -20C -20C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,95 MJ/m 1,95 MJ/m
Copper weight: 45,00 kg/km 45,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
Application
HELUKABEL Profibus PA Armoured finds use in areas with rodent such as rats, nutria etc. but also offers additional protection against all other outside
mechanical influences thanks to it steel tape armouring. The colour blue identifies it as suitable for use in potentially explosive areas (and ATEX/ Class
II, EX-i/EN 60079-14). For other applications, the colour black is usually selected. R
Part no. 802180, Profibus PA 802181, Profibus PA
Dimensions and specifications may be changed without prior notice.
715
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus PA
Long Distance
Electrical data
Characteristic impedance: 100 Ohm 20 % 100 Ohm 20 %
Conductor resistance, max.: 24 Ohm/km 24 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 48 Ohm/km max. 48 Ohm/km max.
Mutual capacitance: 60 nF/km nom. 60 nF/km nom.
Nominal voltage: 300 V 300 V
Test voltage: 1 kV 1 kV
Attenuation: 39 kHz 2,7 dB/km 39 kHz 2,7 dB/km
Technical data
Weight: app. 131 kg/km app. 131 kg/km
bending radius, repeated: 100 mm 100 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,57 MJ/m 1,57 MJ/m
Copper weight: 62,00 kg/km 62,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: UL Style 2571 UL Style 2571
Application
HELUKABEL Profibus PA Long Distance is used for especially long transmission distances in process networks. It uses a larger conductor cross-section
to satisfy the attenuation requirements. The colour blue identifies it as suitable for use in potentially explosive areas (and ATEX/Class II, EX-i/EN
60079-14). For other applications, the colour black is usually selected.
716
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus SK
Indoor + Outdoor
Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 35 nF/km nom. 35 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 2,5 dB/km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/km 38,4 kHz < 4,0 dB/km
4,0 MHz < 22,0 dB/km 4 MHz < 22,0 dB/km
16,0 MHz < 42,0 dB/km 16 MHz < 42,0 dB/km
Technical data
Weight: app. 79 kg/km app. 65 kg/km
bending radius, repeated: 120 mm 120 mm
Operating temperature range min.: -40C -20C
Operating temperature range max.: +80C +70C
Caloric load, approx. value: 1,068 MJ/m 1,451 MJ/m
Copper weight: 24,00 kg/km 24,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to IEC 60332-3 Halogen-free acc. to 60754-2
UL Style: CMG 75C or CL3 or AWM 21694 600V -
CSA standard: CSA FT 4 -
Application R
HELUKABEL Profibus SK Indoor + Outdoor have a special structure for processing with the Fast Connect Stripping Tool from Siemens. The indoor
version is used for normal requirements in fixed installation applications in equipment; the Outdoor version is used in open-air applications, i.e. can
withstand wind, weather and sun (not for burial directly in the ground).
717
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus SK
FRNC + Robust
Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 55 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 110 Ohm/km max. 110 Ohm/km max.
Mutual capacitance: 35 nF/km nom. 35 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 2,5 dB/km 9,6 kHz < 2,5 dB/km
38,4 kHz < 4,0 dB/km 38,4 kHz < 4,0 dB/km
4 MHz < 22,0 dB/km 4 MHz < 22,0 dB/km
16 MHz < 42,0 dB/km 16 MHz < 42,0 dB/km
Technical data
Weight: app. 73 kg/km app. 71 kg/km
bending radius, repeated: 160 mm 120 mm
Operating temperature range min.: -25C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,203 MJ/m 1,574 MJ/m
Copper weight: 24,00 kg/km 24,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to IEC 60332-1
UL Style: CM 750C (shielded) AWM Style 20236 AWM I/II A/B 80C 30V
FT1
CSA standard: - CSA FT1
Application
HELUKABEL Profibus SK FRNC + Robust has a special structure for processing with the Fast Connect Stripping Tool from Siemens. The FRNC version
is used to satisfy halogen-free and flame-retardent requirements in buildings. The Rpbust version is used in harsh industrial environments and offers
excellent resistance to mineral oils, greases and cooling lubricants.
718
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Profibus SK
Drag Chain
Electrical data
Characteristic impedance: 150 Ohm 10 % 150 Ohm 10 %
Conductor resistance, max.: 67 Ohm/km 67 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 134 Ohm/km max. 134 Ohm/km max.
Mutual capacitance: 35 nF/km nom. 35 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Attenuation: 9,6 kHz < 3,0 dB/km 9,6 kHz < 3,0 dB/km
38,4 kHz < 5,0 dB/km 38,4 kHz < 5,0 dB/km
4 MHz < 25,0 dB/km 4 MHz < 25,0 dB/km
16 MHz < 52,0 dB/km 16 MHz < 52,0 dB/km
Technical data
Weight: app. 70 kg/km app. 70 kg/km
bending radius, repeated: 100 mm 100 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,53 MJ/m 1,53 MJ/m
Copper weight: 25,00 kg/km 25,00 kg/km
Norms
Applicable standards: Profibus acc. to DIN 19245 T3 and EN50170 Profibus acc. to DIN 19245 T3 and EN50170
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: CMX 75C (shielded) CMX 75C (shielded)
CSA standard: CSA FT1 CSA FT1
R
Application
HELUKABEL Profibus SK drag chain is designed for continous motion in cable carriers and has a special structure for processing with the Fast Connect
Stripping Tool from Siemens. Thanks to the PU sheath, it also offers excellent resistance to common mineral oils, greases and cooling lubricants.
Depending on the application, the colour petrol or violet is availiable.
719
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
FOUNDATION Fieldbus
Basic
Electrical data
Characteristic impedance: 100 Ohm 20 Ohm
Conductor resistance, max.: 22 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 44 Ohm/km max.
Mutual capacitance: 60 nF/km nom.
Nominal voltage: 300 V
Test voltage: 1,5 kV
Attenuation: 39 kHz 3,4 dB/km
Technical data
Weight: app. 85 kg/km
bending radius, repeated: 80 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Caloric load, approx. value: 1,22 MJ/m
Copper weight: 45,00 kg/km
Norms
Applicable standards: Foundation Fieldbus Spec. FF-816-1.4
Flame-retardant acc. to IEC 60332-3
UL Style: CMG 75C PLTC FT4
CSA standard: CSA FT 4
Application
HELUKABEL FOUNDATION Fieldbus Basic for normal requirements in this industrial networks. Thanks to use of stranded conductors, this cable can
be moved occasionally and satisfies the usual American requirements for such networks.
720
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
FOUNDATION Fieldbus
Type A + gnye
Electrical data
Characteristic impedance: 100 Ohm 20 Ohm
Conductor resistance, max.: 24 Ohm/km
Insulation resistance, min.: 2 GOhm x km
Loop resistance: 48 Ohm/km max.
Mutual capacitance: 65 nF/km nom.
Nominal voltage: 300 V
Test voltage: 1,5 kV
Attenuation: 39 kHz 3,4 dB/km
Technical data
Weight: app. 84 kg/km
bending radius, repeated: 80 mm
Operating temperature range min.: -25C
Operating temperature range max.: +105C
Caloric load, approx. value: 1,00 MJ/m
Copper weight: 49,00 kg/km
Norms
Applicable standards: Foundation Fieldbus Spec. FF-816-1.4
Flame-retardant acc. to IEC 60332-3
UL Style: CMG 105 or CL3 FT4
CSA standard: CSA FT 4
R
Application
HELUKABEL FOUNDATION Fieldbus Type A + gnge offers an additional conductor in the structure in compliance with the FF specification. Thanks
to use of stranded conductors, this cable can be moved occasionally and satisfies the usual American requirements for such networks.
721
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
FOUNDATION Fieldbus
Type A armoured
Electrical data
Characteristic impedance: 100 Ohm 20 Ohm
Conductor resistance, max.: 24 Ohm/km
Insulation resistance, min.: 2 GOhm x km
Loop resistance: 48 Ohm/km max.
Mutual capacitance: 65 nF/km nom.
Nominal voltage: 300 V
Test voltage: 1,5 kV
Attenuation: 39 kHz 3,4 dB/km
Technical data
Weight: app. 187 kg/km
bending radius, repeated: 130 mm
Operating temperature range min.: -25C
Operating temperature range max.: +105C
Caloric load, approx. value: 1,65 MJ/m
Copper weight: 125,00 kg/km
Norms
Applicable standards: Foundation Fieldbus Spec. FF-816-1.4
Flame-retardant acc. to IEC 60332-3
UL Style: CMG 105C or PLTC FT4 Sun Res
CSA standard: CSA FT 4
Application
HELUKABEL FOUNDATION Type A Armoured finds use in areas with rodents such as rats, nutria etc. but also offers additional protection against
all other outside mechanical influences thanks to its corrugated tape armouring. Thanks to use of stranded conductors, this cable can be moved
occasionally and satisfies the usual American requirements for such networks.
722
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
FOUNDATION Fieldbus
Type A
Electrical data
Characteristic impedance: 100 Ohm 20 Ohm
Conductor resistance, max.: 24 Ohm/km
Insulation resistance, min.: 2 GOhm x km
Loop resistance: 48 Ohm/km max.
Mutual capacitance: 65 nF/km nom.
Nominal voltage: 300 V
Test voltage: 1,5 kV
Attenuation: 39 kHz 3,4 dB/km
Technical data
Weight: app. 89 kg/km
bending radius, repeated: 80 mm
Operating temperature range min.: -40C
Operating temperature range max.: +105C
Caloric load, approx. value: 1,05 MJ/m
Copper weight: 42,00 kg/km
Norms
Applicable standards: Foundation Fieldbus Spec. FF-816-1.4
Flame-retardant acc. to IEC 60332-3
UL Style: CMG 105 or CL3 FT4
CSA standard: CSA FT 4
Application
HELUKABEL FOUNDATION Fieldbus Type A for normal requirements in this industrial network. Thanks to use of stranded conductors, this cable
can be moved occasionally and satisfies the usual American requirements for such networks. R
Part no. 801193, Foundation Fieldbus FF A
Dimensions and specifications may be changed without prior notice.
723
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
HMCB200
fixed installed
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 90 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 180 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Test voltage: 0,5 kV
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (db/100m) 8,0 10,0 20,0 27,0
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 39,0 34,0 15,0 5,0
Technical data
Weight: app. 63 kg/km
bending radius, repeated: 70 mm
Operating temperature range min.: -20C
Operating temperature range max.: +80C
Caloric load, approx. value: 0,92 MJ/m
Copper weight: 35,00 kg/km
Norms
Applicable standards: Flame-retardant acc. to IEC 60332-1
UL Style: AWM Style 2502 AWM I/II A/B 80C 30V FT1
Application
HELUKABEL HMCB200 for fixed installation and slight occasional movement, range up to 100m. This cable is used in Siemens Systems.
Typical plugs are RJ45 Industrial IP20 Siemens or Y-Con RJ45 Yamaichi or round M-Connectors from Molex.
724
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
HMCB500S
Drag Chain
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 90 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 180 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Test voltage: 0,5 kV
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (db/100m) 10,0 12,0 23,0 30,0
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 37,0 36,0 12,0 2,0
Technical data
Weight: app. 66 kg/km
bending radius, repeated: 125 mm
Operating temperature range min.: 0C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,00 MJ/m
Copper weight: 38,00 kg/km
Norms
Applicable standards:
UL Style:
Flame-retardant acc. to IEC 60332-1
AWM Style 2502 AWM I/II A/B 80C 30V FT1 R
CSA standard: CSA FT1
Application
HELUKABEL HMCB500S is designed for occasional moving in cable carriers and ranges up to 100m without repeater. This cable is used in Siemens
Systems.
Typical plugs are RJ45 Industrial IP20 Siemens or Y-Con RJ45 Yamaichi or round M-Connectors from Molex.
725
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
HMCB800
Drag Chain
Electrical data
Characteristic impedance: 100 Ohm 15 ohm at 1 to 100 MHz
Conductor resistance, max.: 100 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 270 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Test voltage: 0,5 kV
Typical values
Frequency (MHz) 10 16 62,5 100
Attenuation (db/100m) 8,0 10,0 20,0 27,0
Next (db) 47,0 44,0 35,0 32,0
ACR (db) 39,0 34,0 15,0 5,0
Technical data
Weight: app. 61 kg/km
bending radius, repeated: 75 mm
Operating temperature range min.: -20C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,90 MJ/m
Copper weight: 40,00 kg/km
Norms
Applicable standards: Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
UL Style: AWM Style 20236 AWM I/II A/B 80C 30V FT1
CSA standard: CSA FT1
Application
HELUKABEL HMCB800W is designed for the most demanding continous moving requirements in cable carriers and ranges up to 70 m without
repeater. This cable is ideal solution in Siemens systems.
Typical plugs are RJ45 Industrial IP20 Siemens or Y-Con RJ45 Yamaichi or round M-Connectors from Molex.
726
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
USB Bus S
Drag Chain
Electrical data
Characteristic impedance: 90 Ohm 15 %
Conductor resistance, max.: 230 Ohm/km
Insulation resistance, min.: 0,1 GOhm x km
Loop resistance: 460 Ohm/km max.
Mutual capacitance: 60 nF/km nom.
Test voltage: 0,5 kV
Typical values
Frequency (MHz) 10 16 62,5 100 200 300 400
Attenuation (db/100m) 10,1 15,4 31,0 39,7 60,2 76,2 99,7
Technical data
Weight: app. 45 kg/km
bending radius, repeated: 50 mm
Operating temperature range min.: -30C
Operating temperature range max.: +60C
Caloric load, approx. value: 0,55 MJ/m
Copper weight: 30,00 kg/km
Norms
Applicable standards: USB-Standard 2.0
Halogen-free acc. to 60754-2
UL Style:
Flame-retardant CSA FT1
AWM 20963 (80C/30V) R
CSA standard: CSA FT1
Application
HELUKABEL USB BUS S is designed for continous moving in cable carriers and lengths up to max. 5m. Conventional USB cables fail within a short
period of time, which is why HELUKABEL developed this special cable. Thanks to the PU sheath, it also offers excellent resistance to common mineral
oils, greases and cooling lubricants.
727
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
USB Bus L
Drag Chain
Electrical data
Characteristic impedance: 90 Ohm 15 %
Conductor resistance, max.: 36 Ohm/km
Insulation resistance, min.: 0,2 GOhm x km
Loop resistance: 71 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Nominal voltage: 300 V
Test voltage: 2 kV
Typical values
Frequency (MHz) 1 24 48 96 200 400
Attenuation (db/100m) 4,0 19,0 27,0 38,0 64,0 116,0
Technical data
Weight: app. 56 kg/km
bending radius, repeated: 95 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Caloric load, approx. value: 0,57 MJ/m
Copper weight: 40,00 kg/km
Norms
Applicable standards: USB-Standard 2.0
Flame-retardant acc. to IEC 60332-1
UL Style: AWM 21198 (80C/ 300V)
Application
HELUKABEL USB BUS L is designed for continous motion in cable carriers and lengths up to max. 10m without a repeater. Conventional USB cables
fail within a short period of time and need a repeater after a cable length of 5m, which is why HELUKABEL developed this special cable with a larger
cross-section. Thanks to the PU sheath, it also offers excellent resistance to common mineral oils, greases and cooling lubricants.
728
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
USB Bus 3.0
Drag Chain
Electrical data
Characteristic impedance: 90 Ohm 20 %
105 Ohm 15% at 1 MHz
Conductor resistance, max.: 205 Ohm/km
Insulation resistance, min.: 2 GOhm x km
Loop resistance: 410 Ohm/km max.
Mutual capacitance: 60 nF/km nom.
Test voltage: 0,7 kV
Relative propagation velocity: 75 %
Typical values
Frequency (MHz) 1 625 1200
Attenuation (db/100m) 4,0 115 180
Technical data
Weight: app. 62 kg/km
bending radius, repeated: 55 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Caloric load, approx. value: 0,69 MJ/m
Copper weight: 42,00 kg/km
Norms
Applicable standards: USB-Standard 3.0
Halogen-free acc. to 60754-2 R
Flame-retardant acc. to IEC 60332-1
UL Style: AWM Style 20236 AWM I/II A/B 80C 30V FT1
CSA standard: CSA FT1
Application
HELUKABEL USB S 3.0, designed specifically for use in heavy-duty industries, are the ideal solution for highly-flexible applications such as drag chains
and camera technology. They guarantee superior transmission properties. The transmission distance is connected with the transmission rate.
729
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
Coax 50 Ohm, PUR
Drag Chain
Electrical data
Characteristic impedance: 50 Ohm 2 Ohm
Conductor resistance, max.: 38 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Test voltage: 2 kV
Relative propagation velocity: 67 %
Typical values
Frequency (MHz) 50 100 200 300 500 800 900 1000 1800 2000
Attenuation (db/100m) 11,5 16,5 24,0 30,0 40,0 52,0 59,0 65,0 105,0 112,0
Technical data
Weight: app. 45 kg/km
bending radius, repeated: 54 mm
Operating temperature range max.: +50C
Laying temperature range min.: -20C
Laying temperature range max.: +50C
Copper weight: 23,00 kg/km
Norms
Applicable standards: Halogen-free acc. to 60754-2
Application
This Coax cable, designed specifically for use in heavy-duty industries, is the ideal solution for highly-flexible applications such as drag chains. It guarantee
superior transmission properties.
730
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
fixed installed
Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 88 Ohm/km 88 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 175 Ohm/km max. 175 Ohm/km max.
Mutual capacitance: 58 nF/km nom. 58 nF/km nom.
Nominal voltage: 30 V 30 V
Test voltage: 1,5 kV 1,5 kV
Technical data
Weight: app. 41 kg/km app. 60 kg/km
bending radius, repeated: 81 mm 107 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,574 MJ/m 1,234 MJ/m
Copper weight: 17,00 kg/km 21,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571 UL Style 2571
Application
HELUKABEL CAN Bus for fixed installation and occasional motion, for normal requirements. The 2-pair version is designed with star-quad twisting,
i.e. diagonal conductors form an electrial pair and satisfy the requirements of the CAN Standard. For cable lengths up to max. 40m (observe CAN
specifications).
731
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
fixed installed
Electrical data
Characteristic impedance: 120 Ohm 10 %
Conductor resistance, max.: 87,6 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 175 Ohm/km max.
Mutual capacitance: 40 nF/km nom.
Nominal voltage: 30 V
Test voltage: 1,5 kV
Technical data
Weight: app. 60 kg/km
bending radius, repeated: 113 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,13 MJ/m
Copper weight: 32,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to IEC 60332-1
UL Style: UL Style 2571
CSA standard: CSA FT1
Application
HELUKABEL CAN BUS for fixed installation and occasion motion, for normal requirements. The two signal pairs are provided in the form twisted pais.
As a result, the diameter is somewhat larger than that of 81287. In the event of diameter problems, please see this type. For cable lengths up to max.
40m ( observe CAN specifications).
732
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
fixed installed, 105C
Electrical data
Characteristic impedance: 120 Ohm 10 %
Conductor resistance, max.: 87,2 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 174 Ohm/km max.
Mutual capacitance: 42 nF/km nom.
Nominal voltage: 600 V
Test voltage: 2,5 kV
Technical data
Weight: app. 80 kg/km
bending radius, repeated: 126 mm
Operating temperature range min.: -40C
Operating temperature range max.: +105C *
Caloric load, approx. value: 1,31 MJ/m
Copper weight: 40,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2
Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
UL Style: UL/CSA 21223 80C, 600V
Application
HELUKABEL CAN Bus for fixed installation up to 105C in difficult industrial environments with demanding temperature requirements thanks to
cross-linking of the conductor insulation. Thanks to use a PU sheath, this version is also halogen-free. For cable lengths up to max. 40m (observe CAN
specifications).
R
Part no. 801982, CAN BUS
Dimensions and specifications may be changed without prior notice.
733
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
fixed installed
Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 57 Ohm/km 57 Ohm/km
Insulation resistance, min.: 5 GOhm x km 5 GOhm x km
Loop resistance: 114 Ohm/km max. 114 Ohm/km max.
Mutual capacitance: 58 nF/km nom. 40 nF/km nom.
Nominal voltage: 30 V 30 V
Test voltage: 2 kV 2 kV
Technical data
Weight: app. 65 kg/km app. 77 kg/km
bending radius, repeated: 98 mm 120 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,109 MJ/m 1,179 MJ/m
Copper weight: 23,00 kg/km 30,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571 UL Style 2571
Application
HELUKABEL CAN Bus for fixed installation and occasional motion, for normal requirements. The 2-pair version is designed with a star-quad twisting,
i.e. diagonal conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lenghts up to max. 40m (observe CAN
specifications).
734
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
fixed installed
Electrical data
Characteristic impedance: 120 Ohm 10 %
Conductor resistance, max.: 55,4 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 110 Ohm/km max.
Mutual capacitance: 40 nF/km nom.
Nominal voltage: 250 V
Test voltage: 1,5 kV
Technical data
Weight: app. 85 kg/km
bending radius, repeated: 130 mm
Operating temperature range min.: -40C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,32 MJ/m
Copper weight: 46,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to IEC 60332-1
UL Style: CMX 75C (shielded)
CSA standard: CSA FT1
Application
HELUKABEL CAN Bus for fix installations an occasion motion, for normal requirements. The two signal pairs are provided in the form twisted pairs.
As a result, the diameter is somewhat larger than that of 801573. In the event of diameter problems, please see this type. For cable lengths up to
max. 40m (observe CAN specifications).
R
Part no. 803344, CAN BUS
Dimensions and specifications may be changed without prior notice.
735
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
fixed installed
Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 33 Ohm/km 37 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 66 Ohm/km max. 74 Ohm/km max.
Mutual capacitance: 40 nF/km nom. 44 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Technical data
Weight: app. 69 kg/km app. 100 kg/km
bending radius, repeated: 100 mm 130 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,09 MJ/m 1,64 MJ/m
Copper weight: 30,00 kg/km 45,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571 UL Style 2571
Application
HELUKABEL CAN Bus for fixed installation and occasion motion, for normal requirements. The 2-pair version is designed with star-quad twisting,
i.e. diagonal conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lengths up to 600m (observe CAN
specifications).
736
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
fixed installed
Electrical data
Characteristic impedance: 120 Ohm 10 %
Conductor resistance, max.: 34,4 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 68 Ohm/km max.
Mutual capacitance: 40 nF/km nom.
Nominal voltage: 250 V
Test voltage: 1,5 kV
Technical data
Weight: app. 116 kg/km
bending radius, repeated: 150 mm
Operating temperature range min.: -40C
Operating temperature range max.: +70C
Caloric load, approx. value: 1,62 MJ/m
Copper weight: 60,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to IEC 60332-1
UL Style: CMX 75C (shielded)
CSA standard: CSA FT1
Application
HELUKABEL CAN Bus for fixed installation and occasion motion, for normal requirements. The two signal pairs are provided in the form twisted pairs.
As a result, the diameter is somewhat larger than that of 800685. In the event of diameter problems, please see this type. For cable lengths up to
600m (observe CAN specifications).
R
Part no. 803722, CAN BUS
Dimensions and specifications may be changed without prior notice.
737
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
direct Burial
Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 37 Ohm/km 36,4 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 74 Ohm/km max. 72 Ohm/km max.
Mutual capacitance: 40 nF/km nom. 44 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Technical data
Weight: app. 105 kg/km app. 115 kg/km
bending radius, repeated: 150 mm 160 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 2,05 MJ/m 2,18 MJ/m
Copper weight: 33,00 kg/km 45,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Application
HELUKABEL CAN Bus Direct Burial is suitable for fixed outdoor installation or direct burial applications. The 2-pair version is designed with star-quad
twisting, i.e. diagonal conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lengths up to 600m (observe
CAN specifications).
738
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
fixed installed
Electrical data
Characteristic impedance: 120 Ohm 15 % 120 Ohm 15 %
Conductor resistance, max.: 27,5 Ohm/km 27,5 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 55 Ohm/km max. 55 Ohm/km max.
Mutual capacitance: 42 nF/km nom. 42 nF/km nom.
Nominal voltage: 300 V 300 V
Test voltage: 1,5 kV 1,5 kV
Technical data
Weight: app. 101 kg/km app. 112 kg/km
bending radius, repeated: 110 mm 110 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,67 MJ/m 1,76 MJ/m
Copper weight: 40,00 kg/km 58,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: UL Style 2571 UL Style 2571
CSA standard: CSA FT1 CSA FT1
Application
HELUKABEL CAN Bus for fix installation and occasion motion, for normal requirements. The 2-pair version is designed with star-quad twisting, i.e.
diagonal conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lengths over 600m (observe CAN specifications).
739
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
Drag Chain
Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 74 Ohm/km 85 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 148 Ohm/km max. 170 Ohm/km max.
Mutual capacitance: 50 nF/km nom. 50 nF/km nom.
Test voltage: 1,5 kV 1,5 kV
Technical data
Weight: app. 40 kg/km app. 45 kg/km
bending radius, repeated: 90 mm 95 mm
Operating temperature range min.: -40C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,798 MJ/m 0,943 MJ/m
Copper weight: 18,00 kg/km 25,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Application
HELUKABEL CAN Bus is designed for guided continous motion in cable carriers. The 2-pair version is designed with a star-quad twisting, i.e. diagonal
conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lengths up to max. 40m (observe CAN specifications).
Part no. 81911, CAN BUS, highly flexible 81912, CAN BUS, highly flexible
Dimensions and specifications may be changed without prior notice.
740
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CAN Bus
Drag Chain, UL
Electrical data
Characteristic impedance: 120 Ohm 15 % 120 Ohm 15 %
Conductor resistance, max.: 56 Ohm/km 56 Ohm/km
Insulation resistance, min.: 5 GOhm x km 5 GOhm x km
Loop resistance: 170 Ohm/km max. 170 Ohm/km max.
Mutual capacitance: 40 nF/km nom. 40 nF/km nom.
Nominal voltage: 250 V 250 V
Test voltage: 1,5 kV 1,5 kV
Technical data
Weight: app. 54 kg/km app. 64 kg/km
bending radius, repeated: 105 mm 130 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,20 MJ/m 1,20 MJ/m
Copper weight: 30,00 kg/km 42,00 kg/km
Norms
Applicable standards: CAN Bus acc. to ISO 11898-2 CAN Bus acc. to ISO 11898-2
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: CMX 444 CMX 444
Application
HELUKABEL CAN Bus is designed for guided continous motion in cable carriers. The 2-pair version is designed with star-quad twisting, i.e. diagonal
conductors form an electrical pair and satisfy the requirements of the CAN standard. For cable lengths up to max. 40m (observe CAN specifications).
Part no. 802182, CAN BUS, highly flexible 802339, CAN BUS, highly flexible R
Dimensions and specifications may be changed without prior notice.
741
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
I-BUS
fixed installed
Electrical data
Characteristic impedance: 100 Ohm 15 Ohm 100 Ohm 15 Ohm
Conductor resistance, max.: 96 Ohm/km 96 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 192 Ohm/km max. 192 Ohm/km max.
Mutual capacitance: 60 nF/km nom. 60 nF/km nom.
Test voltage: 1 kV 1 kV
Attenuation: 256 kHz < 1,5 dB/100m 256 kHz < 1,5 dB/100m
772 kHz < 2,4 dB/100m 772 kHz < 2,4 dB/100m
1 MHz < 2,7 dB/100m 1 MHz < 2,7 dB/100m
4 MHz < 5,2 dB/100m 4 MHz < 5,2 dB/100m
10 MHz < 8,4 dB/100m 10 MHz < 8,4 dB/100m
16 MHz < 11,2 dB/100m 16 MHz < 11,2 dB/100m
20 MHz < 11,9 dB/100m 20 MHz < 11,9 dB/100m
Technical data
Weight: app. 70 kg/km app. 96 kg/km
bending radius, repeated: 110 mm 120 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 1,20 MJ/m 1,31 MJ/m
Copper weight: 35,00 kg/km 68,00 kg/km
Norms
Applicable standards: interbus specification 2.0, IEC61158 interbus specification 2.0, IEC61158
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: UL Style 2571 UL Style 2571
Application
HELUKABEL I-Bus is designed for fixed installation and occasional motion, for normal Interbus installation and as a hybrid cable with integrated
power supply.
742
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
I-BUS
fixed installed, halogenfree
Electrical data
Characteristic impedance: 100 Ohm 15 Ohm
Conductor resistance, max.: 96 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Loop resistance: 192 Ohm/km max.
Mutual capacitance: 50 nF/km nom.
Test voltage: 1 kV
Attenuation: 256 kHz < 1,5 dB/100m
772 kHz < 2,4 dB/100m
1 MHz < 2,7 dB/100m
4 MHz < 5,2 dB/100m
10 MHz < 8,4 dB/100m
16 MHz < 11,2 dB/100m
20 MHz < 11,9 dB/100m
Technical data
Weight: app. 67 kg/km
bending radius, repeated: 110 mm
Operating temperature range min.: -25C
Operating temperature range max.: +60C
Caloric load, approx. value: 1,10 MJ/m
Copper weight: 35,00 kg/km
Norms
Applicable standards: interbus specification 2.0, IEC61158
Halogen-free acc. to 60754-2
Application R
HELUKABEL I-Bus is halogen-free and designed for fixed installation in buildings in an Interbus network. The cable is used in dry areas where its
halogen-free construction is a major aspect.
743
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
I-BUS
Drag Chain
Electrical data
Characteristic impedance: 100 Ohm 15 Ohm 100 Ohm 15 Ohm
Conductor resistance, max.: 96 Ohm/km 96 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 192 Ohm/km max. 192 Ohm/km max.
Mutual capacitance: 60 nF/km nom. 60 nF/km nom.
Test voltage: 1 kV 1 kV
Attenuation: 256 kHz < 1,5 dB/100m 256 kHz < 1,5 dB/100m
772 kHz < 2,4 dB/100m 772 kHz < 2,4 dB/100m
1 MHz < 2,7 dB/100m 1 MHz < 2,7 dB/100m
4 MHz < 5,2 dB/100m 4 MHz < 5,2 dB/100m
10 MHz < 8,4 dB/100m 10 MHz < 8,4 dB/100m
16 MHz < 11,2 dB/100m 16 MHz < 11,2 dB/100m
20 MHz < 11,9 dB/100m 20 MHz < 11,90 dB/100m
Technical data
Weight: app. 63 kg/km app. 92 kg/km
bending radius, repeated: 120 mm 130 mm
Operating temperature range min.: -20C -20C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,937 MJ/m 1,227 MJ/m
Copper weight: 36,00 kg/km 70,00 kg/km
Norms
Applicable standards: interbus specification 2.0, IEC61158 interbus specification 2.0, IEC61158
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to EN 50265-2-1
Application
HELUKABEL I-Bus is designed for guided continuous motion in cable carriers and as strictly a bus cable or a hybrid version (with integrated power
supply). Both versions feature a halogen-free PU jacket.
744
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS-Cables
Multibus I, high flexible
Electrical data
Characteristic impedance: 150 + -15 Ohm (Profibus)
120 + -12 Ohm (DeviceNetTM)
100 + -15 Ohm (Interbus)
Conductor resistance: <= 20 Ohm/km (power cores + protection core)
<= 70 Ohm/km (Profibus)
<= 70 Ohm/km (DeviceNetTM)
<= 80 Ohm/km (Interbus)
Insulation resistance: >= 500 Mohm x km (at 20 C)
Mutual capacitance: 30 pF/m nominal (Profibus)
40 pF/m nominal (DeviceNetTM)
50 pF/m nominal (Interbus)
Testvoltage: 2500 V (core/ core)
1500 V (core/ screen)
Mechanical data
Bending radius single: <= 70 mm
Bending radius repeated: <= 110 mm
Tensile strength static: 300 N
Tensile strength dynamic: 140 N
Oil resistance: Diesel, IRM 902, Biohydran TM68, Ecocut HFN 10LE
Flame resistance: IEC 60332-1, VW1/ FT1 acc. C-UL
FCKW free: yes
Self extinguishable: yes R
Other attributes: PVC free, free of lacquer wetting disturbing substances, siliconfree,
resistant against PVC flexibiliser and cable fat RB1
Thermal attributes
Operating temperature range: - 40 C to + 80 C
Laying temperature range: - 30 C to + 80 C
Application HELUKABEL Multibus I is highly flexible with a special structure for use in cable carrier
applications and robotics (use in acc. with HELU specification) in a PVC-free design.
The Multibus I combines the Profibus / DeviceNet / Interbus bus systems as well as
the power supply in a single hybrid cable.
745
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS-Cables
Multibus II, high flexible
Electrical data
Characteristic impedance: 150 + -15 Ohm (Profibus)
100 + -15 Ohm (PROFInet)
Conductor resistance: <= 20 Ohm/km (power cores + protection core)
<= 70 Ohm/km (Profibus)
<= 62 Ohm/km (PROFInet)
Insulation resistance: >= 500 Mohm x km (at 20 C)
Mutual capacitance: 30 pF/m nominal (Profibus)
40 pF/m nominal (PROFInet)
Testvoltage: 2500 V (core/ core)
1500 V (core/ screen)
Mechanical data
Bending radius single: <= 70 mm
Bending radius repeated: <= 110 mm
Tensile strength static: 300 N
Tensile strength dynamic: 140 N
Oil resistance: Diesel, IRM 902, Biohydran TM68, Ecocut HFN 10LE
Flame resistance: IEC 60332-1, VW1/ FT1 acc. C-UL
FCKW free: yes
Self extinguishable: yes
Other attributes: PVC free, free of lacquer wetting disturbing substances, siliconfree,
resistant against PVC flexibiliser and cable fat RB1
Thermal attributes
Operating temperature range: - 40 C to + 80 C
Laying temperature range: - 20 C to + 80 C
746
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
A-BUS
EPDM
Electrical data
Conductor resistance, max.: 13,7 Ohm/km 13,7 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 27 Ohm/km max. 27 Ohm/km max.
Nominal voltage: 32 V 48 V
Test voltage: 1 kV at 15 min. 1 kV at 15 min.
Technical data
Weight: app. 70 kg/km app. 70 kg/km
bending radius, repeated: 30 mm 30 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +85C +85C
Caloric load, approx. value: 0,975 MJ/m 0,975 MJ/m
Copper weight: 31,00 kg/km 31,00 kg/km
Norms
Applicable standards: ASI standard ASI standard
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Application
HELUKABEL A-Bus EPDM Rubber for normal use in an AS-I system. Applications include wet/dry areas where the properties of a rubber jacket are
desired. In addition, this material offers benefits such as low compression forces needed when contacting and the best sealing against the AS-I module.
747
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
A-BUS EPDM, Long Distance
Electrical data
Technical data
Weight: app. 130 kg/km app. 130 kg/km
bending radius, repeated: 35 mm 30 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +85C +85C
Caloric load, approx. value: 0,70 MJ/m 0,70 MJ/m
Copper weight: 49,00 kg/km 49,00 kg/km
Norms
Applicable standards: ASI standard ASI standard
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Application
HELUKABEL A-Bus Long Distance EPDM Rubber 2,5mm for normal use in an AS-I system. The enlarged cross-section allows bigger transmission
distances, higher ampacity and this results in savings of supplementary power packs. Applications include wet/dry areas where the properties of a
rubber jacket are desired. In addition, this material offers benefits such as low compression forces needed when contacting and the best sealing against
the AS-I module.
748
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
A-BUS
PUR, UL/CSA
Electrical data
Conductor resistance, max.: 13,7 Ohm/km 13,7 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 27 Ohm/km max. 27 Ohm/km max.
Nominal voltage: 32 V 48 V
Test voltage: 1 kV at 15 min. 1 kV at 15 min.
Technical data
Weight: app. 64 kg/km app. 64 kg/km
bending radius, repeated: 30 mm 30 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 0,965 MJ/m 0,965 MJ/m
Copper weight: 31,00 kg/km 31,00 kg/km
Norms
Applicable standards: ASI standard ASI standard
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
UL Style: AWM Style 20549 AWM Style 20549
CSA standard: CSA FT2 CSA FT2
Application
HELUKABEL A-Bus PU is ideal for use in wet/dry areas thanks to its outstanding characteristics when exposed to common coolants/lubricants. This
version can also be used in cable carriers (special installation conditions must be observed: place wide cable side on inside radius, use partitions and
install flat/round cables separately). These types are approved for use in the American market (UL 1581, FT2) thanks to use of special materials.
749
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
A-BUS PUR 2X2.5 PUR, Long Distance, UL/CSA
Electrical data
Conductor resistance, max.: 8,21 Ohm/km 8,21 Ohm/km
Loop resistance: 16 Ohm/km max. 16 Ohm/km max.
Nominal voltage: 32 V 48 V
Technical data
Weight: app. 140 kg/km app. 140 kg/km
bending radius, repeated: 30 mm 30 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 0,90 MJ/m 0,90 MJ/m
Copper weight: 49,00 kg/km 49,00 kg/km
Norms
Applicable standards: ASI standard ASI standard
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant CSA FT2 Flame-retardant CSA FT2
UL Style: AWM Style 20549 AWM Style 20549
CSA standard: CSA FT2 CSA FT2
Application
AS components are interconnected with this special system cable. With the AS interface, the cable assembly from the control system to the sensor/actuator
is not needed. The AS interface is the field bus system that transmitts both data and power in one single cable. With fast contacting in penetration
technique, the possibility of errors in cabling is largely reduced. The special outer jacket provides protection against oil, grease, and refrigerant lubricants,
and the cable is therefore even suitable for applications in wet surroundings, in machinery and plant construction, as well as in the machine tool and
automotive industry. The PUR variant is suitable for heavy-duty industrial environments.
Because of the cross section 2,5qmm it is possible to realize longer distances.
These types are certified for the American market (UL 1581, FT2) through the use of special materials.
750
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
A-BUS
TPE
Electrical data
Conductor resistance, max.: 13,7 Ohm/km 13,7 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Loop resistance: 27 Ohm/km max. 27 Ohm/km max.
Nominal voltage: 32 V 48 V
Test voltage: 1,5 kV at 15 min. 1,5 kV at 15 min.
Technical data
Weight: app. 70 kg/km app. 70 kg/km
bending radius, repeated: 24 mm 24 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +105C +105C
Caloric load, approx. value: 1,10 MJ/m 1,10 MJ/m
Copper weight: 31,00 kg/km 31,00 kg/km
Norms
Applicable standards: ASI standard ASI standard
Flame-retardant acc. to IEC 60332-1 Flame-retardant acc. to IEC 60332-1
Application
HELUKABEL A-Bus TPE for demanding temperature requirements up to 105 C and flame retardance. The special outer sheath makes the cable
resistant to many oils, greases and cooling lubricants and thus suitable for applications in wet surroundings, in machinery and plant construction as
well as the machine tool and automotive industries.
751
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
AS-Interface
Electrical Cabinet FLIH
Electrical data
Characteristic impedance: 105 Ohm 35 Ohm
Conductor resistance, max.: 23 Ohm/km
Insulation resistance, min.: 0,01 GOhm x km
Loop resistance: 46 Ohm/km max.
Nominal voltage: 300 V
Test voltage: 2 kV at 15 min.
Technical data
Weight: app. 24 kg/km
bending radius, repeated: 30 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Caloric load, approx. value: 0,30 MJ/m
Copper weight: 20,00 kg/km
Norms
Applicable standards: ASI standard
Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-1
UL Style: UL Style 2444
Application
HELUKABEL AS-Interface FLIH for electrical cabinet applications, especially for wiring inside electrical cabinets. Compared to "normal" AS-I wire, less
space is needed and routing is improved. This cable is also designed for appropriate fast contacting through use of the penetration technique. Special
modules for electrical cabinets that are compatible with this wire are available on the market.
752
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
DeviceNet
PVC
Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 22,6 Ohm/km 90 Ohm/km
Insulation resistance, min.: 0,2 GOhm x km 0,2 GOhm x km
Loop resistance: 45 Ohm/km max. 180 Ohm/km max.
Mutual capacitance: 39,8 nF/km nom. 39,8 nF/km nom.
Test voltage: 2 kV 2 kV
Attenuation: 125 kHz < 0,42 dB/100m 125 kHz < 0.95 dB/100m
500 kHz < 0,81 dB/100m 500 kHz < 1.64 dB/100m
Technical data
Weight: app. 192 kg/km app. 67 kg/km
bending radius, repeated: 190 mm 110 mm
Operating temperature range min.: -20C -20C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 2,92 MJ/m 0,91 MJ/m
Copper weight: 88,00 kg/km 35,00 kg/km
Norms
Applicable standards: ODVA DeviceNet ODVA DeviceNet
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style:
CSA standard:
CMG 75C PLTC FT4
CEC: CMG FT4
CMG 75C PLTC FT4
CSA FT 4
R
Application
HELUKABEL DeviceNet PVC for fixed installation. The special aspect of this bus system is that a data pair and a power supply pair are always
integrated in one cable. The small cross-section is used for short distances or as a point-to-point connection; the large cross-section as main conductor
for long distances and frequently in combination with the thin conductor as drain wire.
753
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
DeviceNet
FRNC
Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 22,6 Ohm/km 90 Ohm/km
Insulation resistance, min.: 0,2 GOhm x km 0,2 GOhm x km
Loop resistance: 45 Ohm/km max. 180 Ohm/km max.
Mutual capacitance: 39 nF/km nom. 39,8 nF/km nom.
Test voltage: 2 kV 2 kV
Attenuation: 125 kHz < 0.42 dB/100m 125 kHz < 0.95 dB/100m
500 kHz < 0.81 dB/100m 500 kHz < 1.64 dB/100m
Technical data
Weight: app. 195 kg/km app. 70 kg/km
bending radius, repeated: 190 mm 110 mm
Operating temperature range min.: -25C -25C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 2,73 MJ/m 0,82 MJ/m
Copper weight: 88,00 kg/km 34,00 kg/km
Norms
Applicable standards: ODVA DeviceNet ODVA DeviceNet
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: CL2 CMG CL2 CMG
CSA standard: CEC: CMG FT4 CEC: CMG FT4
Application
HELUKABEL DeviceNet FRNC for fixed installation in areas where high flame retardance and a halogen-free design are needed. The special aspect
of this bus system is that a data pair and a power supply pair are always integrated in one cable. The small cross-section is used for short distances
or as a point-to-point connection; the large cross-section as main conductor for long distances and frequently in combination with the thin conductor
as drain wire.
754
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
DeviceNet
CPE
Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 22,6 Ohm/km 90 Ohm/km
Insulation resistance, min.: 0,2 GOhm x km 0,2 GOhm x km
Loop resistance: 45 Ohm/km max. 180 Ohm/km max.
Mutual capacitance: 39 nF/km nom. 39 nF/km nom.
Test voltage: 2 kV 2 kV
Attenuation: 125 kHz < 0,43 dB/100m 125 kHz < 0,95 dB/100m
500 kHz < 0,82 dB/100m 500 kHz < 1,64 dB/100m
Technical data
Weight: app. 195 kg/km app. 70 kg/km
bending radius, repeated: 190 mm 110 mm
Operating temperature range min.: -20C -20C
Operating temperature range max.: +60C +60C
Caloric load, approx. value: 2,73 MJ/m 0,82 MJ/m
Copper weight: 71,20 kg/km 28,10 kg/km
Norms
Applicable standards: ODVA DeviceNet ODVA DeviceNet
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style:
CSA standard:
CMG PLTC
CEC: CMG FT4
CL2 CMG
CEC: CMG FT4
R
Application
HELUKABEL DeviceNet CPE for fixed installation with very high flame-retardance requirements. The special aspect of this bus system is that a data
pair and a power supply pair are always integrated in one cable. The small cross-section is used for short distances or as a point-to-point connection;
the large cross-section as main conductor for long distances and frequently in combination with the thin conductor as drain wire.
755
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
DeviceNet
PUR, high flexible
Electrical data
Characteristic impedance: 120 Ohm 10 % 120 Ohm 10 %
Conductor resistance, max.: 22,6 Ohm/km 90 Ohm/km
Insulation resistance, min.: 0,2 GOhm x km 0,2 GOhm x km
Loop resistance: 45 Ohm/km max. 45 Ohm/km max.
Mutual capacitance: 39,8 nF/km nom. 39,8 nF/km nom.
Test voltage: 2 kV 2 kV
Attenuation: 125 kHz < 0,41 dB/100m 125 kHz < 0,95 dB/100m
500 kHz < 0,82 dB/100m 500 kHz < 1,64 dB/100m
Technical data
Weight: app. 185 kg/km app. 68 kg/km
bending radius, repeated: 61 mm 70 mm
Operating temperature range min.: -40C -40C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 2,54 MJ/m 0,76 MJ/m
Copper weight: 90,00 kg/km 35,00 kg/km
Norms
Applicable standards: ODVA DeviceNet ODVA DeviceNet
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
UL Style: CMX 75C CL2X CMX 75C CL2X
Application
HELUKABEL DeviceNet PU highly flexible for use in cable carriers with outstanding resistance to common coolants/lubricants. The special aspect
of this bus system is that a data pair and a power supply pair are always integrated in one cable. The small cross-section is used for short distances
or as a point-to- point connection; the large cross-section as main conductor for long distances and frequently in combination with the thin conductor
as drain wire.
756
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
CC-Link BUS
PVC
Electrical data
Characteristic impedance: 110 Ohm 15 Ohm
Conductor resistance, max.: 37,8 Ohm/km
Insulation resistance, min.: 10 GOhm x km
Loop resistance: 75 Ohm/km max.
Mutual capacitance: 60 nF/km nom.
Test voltage: 2 kV
Attenuation: 1 MHz < 16,0 dB/100m
5 MHz < 35,0 dB/100m
Technical data
Weight: app. 77 kg/km
bending radius, repeated: 120 mm
Operating temperature range min.: -40C
Operating temperature range max.: +75C
Caloric load, approx. value: 1,10 MJ/m
Copper weight: 40,00 kg/km
Norms
Applicable standards: CC-Link Specification 1.10
Flame-retardant acc. to EN 50265-2-1
UL Style: CM 75C or PLTC
CSA standard: CSA FT 4
Application
HELUKABEL CC-Link Bus PVC for fixed installation. The primary market is Asia, but the USA and the United Kingdom are using CC-Link increasingly.
The cable has the appropriate approvals for these markets. A version with power supply conductors is optionally available. It is used particularly in R
channels.
757
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
SafetyBUS
FRNC + PUR
Electrical data
Characteristic impedance: 110 Ohm 10 Ohm 110 Ohm 10 Ohm
Conductor resistance, max.: 27,7 Ohm/km 26 Ohm/km
Insulation resistance, min.: 5 GOhm x km 5 GOhm x km
Loop resistance: 52 Ohm/km max. 52 Ohm/km max.
Mutual capacitance: 45 nF/km nom. 45 nF/km nom.
Nominal voltage: 250 V 250 V
Test voltage: 3 kV 3 kV
Attenuation: 1 MHz < 1,6 dB/Km 1 MHz < 1,6 dB/Km
5 MHz < 3,4 dB/Km 5 MHz < 3,4 dB/Km
10 MHz < 5,6 dB/Km 10 MHz < 5,6 dB/Km
16 MHz < 7,5 dB/Km 16 MHz < 7,5 dB/Km
Technical data
Weight: app. 68 kg/km app. 65 kg/km
bending radius, repeated: 75 mm 80 mm
Operating temperature range min.: -25C -30C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 0,72 MJ/m 0,76 MJ/m
Copper weight: 50,00 kg/km 50,00 kg/km
Norms
Applicable standards: abutted at SafetyBUS p technical guidelines abutted at SafetyBUS p technical guidelines
copper wires 1.0 copper wires 1.0
Halogen-free acc. to 60754-2 Halogen-free acc. to 60754-2
Flame-retardant acc. to IEC 60332-3 Flame-retardant acc. to IEC 60332-1
UL Style: - CMX 75C (shielded)
Application
HELUKABEL SafetyBUS FRNC for fixed installation; the PU version is intended for use in cable carriers. Both versions are halogen-free.
758
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
LON BUS
H122 + Y116
Electrical data
Characteristic impedance: 100 Ohm 10 % 85 Ohm 15 %
Conductor resistance, max.: 57 Ohm/km 15,8 Ohm/km
Insulation resistance, min.: 5 GOhm x km 0,02 GOhm x km
Loop resistance: 114 Ohm/km max. 31 Ohm/km max.
Mutual capacitance: 45 nF/km nom. 10 nF/km nom.
Nominal voltage: 125 V 300 V
Test voltage: 0,7 kV 2 kV
Technical data
Weight: app. 25 kg/km app. 65 kg/km
bending radius, repeated: 70 mm 85 mm
Operating temperature range min.: -20C -20C
Operating temperature range max.: +75C +80C
Caloric load, approx. value: 0,337 MJ/m 1,25 MJ/m
Copper weight: 11,00 kg/km 30,00 kg/km
Applicable standards: Halogen-free acc. to 60754-2 Flame-retardant acc. to IEC 60332-1
Flame-retardant acc. to IEC 60332-1
Application
HELUKABEL LON BUS H122 FRNC for fixed installation; version Y116 for mobile applications. For both versions: Use indoors is in fixed installations
(H122) and as a patch cable (Y116) and must comply with DIN EN 50090-2-2 (VDE 0892 Part 2-2:1997-06).
759
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
E-BUS
PVC
Electrical data
Characteristic impedance: 100 Ohm 100 Ohm
Conductor resistance, max.: 73,2 Ohm/km 73,2 Ohm/km
Insulation resistance, min.: 0,1 GOhm x km 0,1 GOhm x km
Loop resistance: 146 Ohm/km max. 146 Ohm/km max.
Mutual capacitance: 100 nF/km nom. 100 nF/km nom.
Test voltage: 4 kV 4 kV
Technical data
Weight: app. 64 kg/km app. 64 kg/km
bending radius, repeated: 95 mm 95 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,90 MJ/m 0,90 MJ/m
Copper weight: 25,00 kg/km 25,00 kg/km
Norms
Applicable standards: EIB standard EIB standard
Flame-retardant acc. to EN 50265-2-1 Flame-retardant acc. to EN 50265-2-1
Application
HELUKABEL E-BUS PVC for fixed installation. The E-Bus cable is intended for transmission of bus signals in intelligent building systems. The cables
ensure perfect communication in compliance with EIB regulations. They can be installed over, in and under plaster, in conduits and cable channels, in
dry, damp and wet rooms as well as outdoors - if protected from direct sunlight. Wiring together with high-power cables is possible without limitation.
The EIB bus can be used to control lighting, blinds, heating, ventilation, indicator boards etc.
760
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
E-BUS
FRNC + PVC
Electrical data
Characteristic impedance: 100 Ohm 100 Ohm
Conductor resistance, max.: 73,2 Ohm/km 73,2 Ohm/km
Insulation resistance, min.: 0,1 GOhm x km 0,1 GOhm x km
Loop resistance: 146 Ohm/km max. 146 Ohm/km max.
Mutual capacitance: 100 nF/km nom. 100 nF/km nom.
Test voltage: 4 kV 4 kV
Technical data
Weight: app. 54 kg/km app. 92 kg/km
bending radius, repeated: 95 mm 120 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Caloric load, approx. value: 0,58 MJ/m 1,37 MJ/m
Copper weight: 25,00 kg/km 41,00 kg/km
Norms
Applicable standards: EIB standard EIB standard
Halogen-free acc. to 60754-2 Flame-retardant acc. to EN 50265-2-1
Flame-retardant acc. to EN 50265-2-1
Application
HELUKABEL E-BUS FRNC + PVC for fixed installation. If the application requires a halogen-free installation, the FRNC version is the right choice. The
E-Bus cable is intended for transmission of bus signals in intelligent building systems. The cables ensure perfect communication in compliance with
EIB regulations. They can be installed over, in and under plaster, in conduits and cable channels, in dry, damp and wet rooms as well as outdoors - if
protected from direct sunlight. Wiring together with high-power cables is possible without limitation. The EIB bus can be used to control lighting,
blinds, heating, ventilation, indicator boards etc. R
Part no. 80826, E-BUS 81077, E-BUS
Dimensions and specifications may be changed without prior notice.
761
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
E-BUS DIRECT BURIAL
PE, ERD
Electrical data
Characteristic impedance: 100 Ohm
Conductor resistance, max.: 73,2 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Loop resistance: 146 Ohm/km max.
Mutual capacitance: 55 nF/km nom.
Test voltage: 0,8 kV
Technical data
Weight: app. 75 kg/km
bending radius, repeated: 130 mm
Operating temperature range min.: -20C
Operating temperature range max.: +70C
Caloric load, approx. value: 2,00 MJ/m
Copper weight: 25,00 kg/km
Norms
Applicable standards: EIB standard
Halogen-free acc. to 60754-2
Application
HELUKABEL E-BUS ERD with PE jacket for fixed installation in the ground or outdoors and as a connection between buildings or to EIB components
on the building. They can be installed over, in and under plaster, in conduits and cable channels, in dry, damp and wet rooms as well as outdoors - if
protected from direct sunlight. Wiring together with high-power cables is possible without limitation. The EIB bus can be used to control lighting,
blinds, heating, ventilation, indicator boards etc.
762
Data, Network and Bus Technology / HELUKABEL BUS-Cables
BUS Cables
KH-BUS
PVC + FRNC
Electrical data
Insulation resistance, min.: 0,02 GOhm x km 0,02 GOhm x km
Mutual capacitance: 70 nF/km nom. 70 nF/km nom.
Test voltage: 2 kV 2 kV
Technical data
Weight: app. 90 kg/km app. 93 kg/km
bending radius, repeated: 120 mm 120 mm
Operating temperature range min.: -40C -25C
Operating temperature range max.: +80C +80C
Caloric load, approx. value: 1,01 MJ/m 0,86 MJ/m
Copper weight: 53,00 kg/km 53,00 kg/km
Application
HELUKABEL KH-BUS PVC + FRNC for fixed installation of patient calling systems. Simple and fast installation is an important factor there. For this
reason, a 6-conductor hybrid cable is used to connect the individual components of the calling system. This cable is used for the power supply, speech
and data transmission. The FRNC version is the right choice when a halogen-free installation is required.
763
MEDIA TECHNOLOGY
Audio Audio cables, multipaired, spirally screened pairs and overall braided shielding 770
Audio Digital audio cables AES/EBU, single pair with spiral screen 771
Audio Digital audio cables AES/EBU, single pair with foil/braided shielding 772
Audio Digital audio cables AES/EBU, multipaired, pair and overall foil shielding 773
Audio Digital audio cables AES/EBU, multipaired, spirally screened pairs and overall foil shielding 774
Audio & Light DMX cables, multicore with spiral screen 778
765
Media Technology
Audio
Audio cables with braided shielding
Electrical data
Conductor resistance, max.: 75 Ohm/km
Insulation resistance, min.: 5 MOhm x km
Technical data
Weight: approx. 20 kg/km
Min. bending radius for laying: 35 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 13,5 kg/km
Application
The HELUSOUND audio cable is a 2-core, shielded multipurpose cable with earth conductor. It is particularly suitable for use in microphone, radio,
studio and transmission systems.
Analog cable for short transmission distances and low frequencies.
766
Media Technology
Audio
Audio cables, multicore, with braided shielding
Electrical data
Conductor resistance, max.: 73,9 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Technical data
Weight: approx. 37 kg/km
Min. bending radius for laying: 52 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 16,8 kg/km
Application
The 2-5-core shielded HELUSOUND audio cable with a common PE core insulation, braided shielding and PVC outer sheath is especially well suited
for use in microphone, loudspeaker, radio and transmission systems.
767
Media Technology
Audio
Audio cables with foil shielding, single pair
Electrical data
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Technical data
Weight: approx. 17 kg/km
Min. bending radius for laying: 35 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 6,6 kg/km
Application
The 2-core HELUSOUND audio cable is a foil shielded cable with earth conductor. This symmetrical cable is suitable for use in racks and for studio
cabling.
768
Media Technology
Audio
Audio cables, multipaired, pairs with foil shielding
Electrical data
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Technical data
Weight: approx. 72 kg/km
Min. bending radius for laying: 76 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 15,0 kg/km
Application
The HELUSOUND audio cable is an insulated, multi-core audio cable which is screened symmetrically and in pairs. The cable is particularly suitable
for permanent laying in public buildings, such as, e.g. theatres or music stages and for permanent studio installation.
769
Media Technology
Audio
Audio cables, multipaired, spirally screened pairs and overall braided shielding
Electrical data
Conductor resistance, max.: 150 Ohm/km 150 Ohm/km
Insulation resistance, min.: 100 MOhm x km 100 MOhm x km
Technical data
Weight: approx. 190 kg/km approx. 247 kg/km
Min. bending radius for laying: 127 mm 142 mm
Operating temperature range min.: -25C -25C
Operating temperature range max.: +70C +70C
Copper weight: 118,0 kg/km 165,0 kg/km
Application
The multipaired HELUSOUND special sound audio cable has individually shielded pairs and is protected by an additional braided shielding and ribbed
PUR sheath. This cable is particularly suitable for use in mobile radio and transmission systems.
770
Media Technology
Audio
AES/EBU digital audio cables, single pair, with spiral screen
Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Technical data
Weight: approx. 35 kg/km
Min. bending radius for laying: 50 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 14,7 kg/km
Application
The HELUSOUND AES/EBU audio cable is a 2-core, symmetrical and shielded digital sound cable with flexible spiral screen and PVC outer sheath.
The cable is suitable for longer transmission rates and larger data volumes, the transmission of digital and analog audio signals and can therefore, for
example, be used for connecting audio amplifiers, digital mixers, DAT recorders etc. The cable is also available with PUR outer sheath.
771
Media Technology
Audio
AES/EBU digital audio cables, single pair, foil/braided shielding
Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Technical data
Weight: approx. 43 kg/km
Min. bending radius for laying: 60 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 16,5 kg/km
Part no. Cable structure Screen Conductor Outer diameter Cop. Weight
resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400022 2x0,22 Foil + braid < 86,0 6,0 16,5 43,0
400023 2x0,22 Foil + braid < 86,0 4,5 15,7 25,0
400024 2x0,22 Foil < 86,0 4,2 7,3 18,0
Application
The HELUSOUND AES/EBU audio cable is a 2-core, symmetrical and shielded digital sound cable. The cable is available in three different versions.
The standard version is characterised by double shielding; the patch variant has reduced outside diameter and the foil shielded variant is suitable for
the permanent wiring of digital devices. All three versions are suitable for the transmission of digital audio signals.
772
Media Technology
Audio
AES/EBU digital audio cables, multipaired, pairs with foil shielding and overall
foil shielding
Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Technical data
Weight: approx. 85 kg/km
Min. bending radius for laying: 100 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 16,0 kg/km
Application
The multipaired, digital HELUSOUND AES/EBU audio cable is characterised by its shielding in pairs, its element sheaths and by the additional overall
sheath. This cable is suitable for the transmission of digital audio signals.
773
Media Technology
Audio
AES/EBU digital audio cables, multipaired, spirally screened pairs and overall
foil shielding
Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Technical data
Weight: approx. 320 kg/km
Min. bending radius for laying: 170 mm
Operating temperature range min.: -20C
Operating temperature range max.: +70C
Copper weight: 171,0 kg/km
Application
The multipaired, digital HELUSOUND AES/EBU audio cable is characterised by its shielding in pairs, its element sheaths and by the additional overall
sheath. This cable is suitable for the transmission of digital audio signals.
774
Media Technology
Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 80 Ohm/km
Insulation resistance, min.: 5 GOhm x km
Technical data
Weight: approx. 33 kg/km
Min. bending radius for laying: 50 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Copper weight: 14,0 kg/km
Application
The 2-core HELUSOUND AES/EBU & DMX patch cable is foil shielded and optimally protected against external interference by its copper spiral screen.
This cable is suitable for indoor use for permanent laying for the control of lighting systems or for patching in studio technology.
775
Media Technology
Electrical data
Characteristic impedance: 110 Ohm 110 Ohm
Conductor resistance, max.: 53 Ohm/km 53 Ohm/km
Insulation resistance, min.: 10 GOhm x km 5 GOhm x km
Technical data
Weight: approx. 50 kg/km approx. 65 kg/km
Min. bending radius for laying: 64 mm 70 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Copper weight: 18,0 kg/km 29,0 kg/km
Application
The 2-core HELUSOUND AES/EBU & DMX patch cable is protected against external interferences by its copper spiral screen. This cable is suitable
for permanent laying for the control of lighting systems or for connecting digital audio amplifiers. It can be installed indoors and outdoors. The max.
transmission path for DMX control amounts approx. 1000m
776
Media Technology
Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 85 Ohm/km
Insulation resistance, min.: 100 GOhm x km
Technical data
Weight: approx. 76 kg/km
Min. bending radius for laying: 80 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 38,0 kg/km
Application
The 4-core HELUSOUND AES/EBU & DMX cable is protected against external interference by its AL/PT foil, its copper spiral screen and its PVC outer
sheath. This cable is suitable for controlling all types of digital equipment. Also to use as microphon cabel.
777
Media Technology
Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 MOhm x km
Technical data
Weight: approx. 79 kg/km
Min. bending radius for laying: 64 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 66,0 kg/km
Application
The 3-core, shielded HELUSOUND digital sound cable consists of a symmetrical pair and an additional third core. A double spiral screen and the PVC
outer sheath protect the cable against electrical interference. This AES/EBU and DMX compliant (110 Ohm) special cable is suitable for the transmission
of digital audio signals and can therefore, for example, be used for connecting digital mixers, audio amplifiers, DAT recorders, light and scanner
systems etc.
778
Media Technology
Light+Power
DMX-POWER
Electrical data
Characteristic impedance: 110 Ohm
Technical data
Weight: approx. 74 kg/km
Copper weight: 36,0 kg/km
Application
The hybrid DMX Power cable is used in the professional DMX light controller. It transmits power for the light and control signals for the movement.
The cable is compact, flexible and easy to process.
779
Media Technology
HELUSOUND DMX+POWER
Electrical data
Characteristic impedance: 110 Ohm
Conductor resistance, max.: 78 Ohm/km
Insulation resistance, min.: 20 GOhm x km
Technical data
Weight: approx. 50 kg/km
Min. bending radius for laying: 64 mm
Operating temperature range min.: -30C
Operating temperature range max.: +70C
Copper weight: 60,5 kg/km
Application
The HELUSOUND DMX+POWER hybrid cable combines a shielded light control wire and the power supply wire. The DMX-cable, which is shielded
by a tin-coated copper braiding is perfectly suited for the control of light systems and mixing boards (110 Ohm characteristic intrinsic impedance). It
highlights a soft PVC insulation and it is qualified for the use at indoor and outdoor installations. The DMX cable can also be used for the transmission
of audio signals such as a microphone wire or as a power supply wire for active loudspeaker systems.
780
Media Technology
Audio
Instrument cables with spiral screen
Electrical data
Conductor resistance, max.: 86 Ohm/km 55 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Technical data
Weight: approx. 44 kg/km approx. 55 kg/km
Min. bending radius for laying: 60 mm 70 mm
Operating temperature range min.: -25C -25C
Operating temperature range max.: +70C +70C
Copper weight: 7,9 kg/km 29,0 kg/km
Application
The HELUSOUND instrument cable with spiral screen is a non-symmetrical, double shielded cable. This cable is specially suitable for connecting high
ohmic components such as synthesisers, keyboards or guitars in professional stage and studio operation. The high-quality 1x0.38 special cable has
an increased cross-section, a semi-conductor layer and a double spiral screen, which makes it suitable for the most stringent requirements of professional
stages and studios.
781
Media Technology
Audio
Microphone cables with spiral screen, paired
Electrical data
Conductor resistance, max.: 86 Ohm/km 120 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Technical data
Weight: approx. 55 kg/km approx. 27 kg/km
Min. bending radius for laying: 60 mm 42 mm
Operating temperature range min.: -25C -25C
Operating temperature range max.: +70C +70C
Copper weight: 12,1 kg/km 14,0 kg/km
Application
The 2-core HELUSOUND microphone cable with spiral screen is suitable for use in professional stage and studio operation. The microphone cable
2x0.15 has a double spiral screen made of bare copper wires.
782
Media Technology
Audio
Microphone cables with braided shielding
Electrical data
Conductor resistance, max.: 53 Ohm/km 37 Ohm/km
Insulation resistance, min.: 1 GOhm x km 1 GOhm x km
Technical data
Weight: approx. 30 kg/km approx. 59 kg/km
Min. bending radius for laying: 65 mm 67 mm
Operating temperature range min.: -30C -30C
Operating temperature range max.: +70C +70C
Copper weight: 15,2 kg/km 37,0 kg/km
Application
The 2-wire HELUSOUND microphone cable with copper braid shield is suitable for use in the professional stage and studio operations, as well as for
fixed installation. The line is characterized by its highly flexible PVC jacket.
783
Media Technology
Audio
Microphone cables with braided shielding, star quads
Electrical data
Conductor resistance, max.: 86 Ohm/km
Insulation resistance, min.: 1 GOhm x km
Technical data
Weight: approx. 50 kg/km
Min. bending radius for laying: 62 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 25,0 kg/km
Application
The 4-core HELUSOUND microphone cable is stranded in star quads and suitable for special application due to its earth conductor and braided
shielding. It is e.g. used as a stereo cable in the area of professional studio and microphone technique.
Easy stripping.
784
Media Technology
Loudspeaker Cables
Cross section (mm) 2 x 0,5 2 x 0,5 2 x 0,75 2 x 0,75 2 x 1,5 2 x 1,5 2 x 2,5 2 x 2,5 2x4 2x4
Part no. 40180 40023 40181 40024 40182 40025 40183 40026 40184 40027
Cable structure
Conductor material: Copper litz wire, bare
Identification: Grooves
Cond. make-up 16 x 0,20 16 x 0,20 24 x 0,20 24 x 0,20 28 x 0,25 28 x 0,25 48 x 0,25 48 x 0,25 55 x 0,30 55 x 0,30
Insulation h x w mm 2,0 x 5,0 2,1 x 4,7 2,2 x 4,9 2,2 x 4,9 2,6 x 5,5 2,6 x 5,5 3,3 x 7,0 3,3 x 7,0 4,3 x 8,2 4,3 x 8,2
Sheath material PVC PVC PVC PVC PVC PVC PVC PVC PVC PVC
Sheath colour transparent black/red transparent black/red transparent black/red transparent black/red transparent black/red
Weight approx. kg / km 15 15 20 20 37 37 63 63 80 80
Electrical characteristics
Loop resistance
max. (Ohm/km) 70 70 47 47 23 23 14 14 9 9
CapacitancepF/m 47 47 60 60 67 67 67 67 64 64
Inductance H/m at
1 kHz 0,7 0,67 0,61 0,61 0,54 0,54 0,54 0,54 0,58 0,58
10 kHz 0,8 0,79 0,73 0,73 0,59 0,59 0,62 0,62 0,65 0,65
100 kHz 0,8 0,85 0,73 0,73 0,59 0,59 0,62 0,62 0,65 0,65
1000 kHz 0,8 0,8 0,67 0,67 0,52 0,52 0,56 0,56 0,59 0,59
Copper weight kg/km 9,6 9,6 14,4 14,4 28,8 28,8 48,0 48,0 76,8 76,8
Cable structure
Conductor material: Bare copper litz wire, highly flexible
Identification: Stripes
Cond. make-up 189 x 0,10 322 x 0,10 511 x 0,10 777 x 0,10 1273 x 0,10
Insulation h x w mm 3,1 x 6,5 3,6 x 7,5 5 x 10,2 6,1 x 12,5 7,0 x 15,0
Sheath material PVC PVC PVC PVC PVC
Sheath colour transparent transparent transparent transparent transparent
Weight approx. kg / km 41 60 79 136 254
Electrical characteristics
Loop resistance
max. (Ohm/km) 23 14 9 6 3
CapacitancepF/m 67 53 50 54 59
Inductance H/m at
1 kHz 0,54 0,48 0,49 0,46 0,45
10 kHz 0,61 0,55 0,56 0,54 0,53
100 kHz 0,62 0,59 0,6 0,56 0,56
1000 kHz 0,55 0,54 0,56 0,53 0,52
Note
The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers.
785
Media Technology
Electrical data
Conductor resistance, max.: 12,7 Ohm/km
Technical data
Weight: approx. 73,4 kg/km
Min. bending radius for laying: 33 mm
Operating temperature range min.: -10C
Operating temperature range max.: +70C
Copper weight: 28,8 kg/km
Application
All products of the HELUSOUND 400 LOUDSPEAKER series impress with their extremely high flexibility. 0,15 stranded wires and a very soft PVC
outer sheath make this possible. These cables are particularly used in mobile applications on stages, in studios or in the conference industry.
786
Media Technology
Electrical data
Conductor resistance, max.: 12,7 Ohm/km
Technical data
Weight: approx. 66,9 kg/km
Min. bending radius for laying: 33 mm
Operating temperature range min.: -25C
Operating temperature range max.: +80C
Copper weight: 28,8 kg/km
Application
The robust solution for medium and high mechanical stresses, as robust, abrasion-resistant and cut resistant. Also suitable for outdoor use.
787
Media Technology
Electrical data
Conductor resistance, max.: 12,7 Ohm/km
Technical data
Weight: approx. 77 kg/km
Min. bending radius for laying: 33 mm
Operating temperature range min.: -5C
Operating temperature range max.: +70C
Copper weight: 28,8 kg/km
Application
The safe solution for increasing demands on the security in case of fire, as flame retardant, low smoke, halogen-free, no corrosion damage by released
gases and fumes, no flame propagation provide for local flame propagation for the integrity of important systems.
788
Media Technology
Audio
Speaker cables, coaxial
Electrical data
Conductor resistance, max.: 7,98 Ohm/km 4,95 Ohm/km
Insulation resistance, min.: 5 MOhm x km 5 MOhm x km
Technical data
Weight: approx. 84 kg/km approx. 129 kg/km
Min. bending radius for laying: 68 mm 80 mm
Operating temperature range min.: -25C -25C
Operating temperature range max.: +70C +70C
Copper weight: 52,0 kg/km 87,0 kg/km
Application
The coaxial HELUSOUND speaker cable is protected by a counter-rotating double spiral shield and outer jacket. It is characterized due to the
construction, in addition to robustness and good drum reeling, especially by high flexibilty and small dimensions.
789
Media Technology
Electrical data
Conductor resistance, max.: 13,3 Ohm/km
Technical data
Weight: approx. 322 kg/km
Min. bending radius for laying: 53,6 mm
Operating temperature range min.: -40C
Operating temperature range max.: +80C
Copper weight: 201,6 kg/km
Loadcable 300/500 V
Part no. Cable structure Conductor Outer diameter Cop. Weight
resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400143 14 G 1,5 < 13,3 13,4 201,6 322,0
400144 18 G 1,5 < 13,3 15,2 259,2 422,0
400145 14 G 2,5 < 7,98 16,6 336,0 487,0
400146 18 G 2,5 < 7,98 19,0 432,0 634,0
Loadcable 0,6/1 kV
Part no. Cable structure Conductor Outer diameter Cop. Weight
resistance approx. mm weight approx. kg / km
Ohm / km kg / km
400147 14 G 1,5 < 13,3 17,7 201,6 430,0
400148 18 G 1,5 < 13,3 20,2 259,2 560,0
400149 14 G 2,5 < 7,98 20,0 336,0 604,0
400150 18 G 2,5 < 7,98 22,6 432,0 778,0
Application
The highly flexible load cables are applied at medium mechanical stress in the professional stage and lighting technology, and other load circuits. The
flexibility is achieved through the building with extra fine 0,15 mm strands and the core and sheath insulation from cold-flexible PVC.
790
Media Technology
Video Cables
used as Indoors Indoors, Indoors Indoors Indoors, Indoors Indoors Indoors Indoors,
underground underground outdoors
Type 0,6/2,8 1,0/6,6 1.0/6.6 2YD 1,0/6,6 1.0/6.6D 0.6L/3.7 0,6/3,7 1.0/6.6D 0,6L/3,7+2x0,75
Part no. 40022 40056 40175 40173 40073 40170 40171 40174 40028
Cable structure
Inner conductor diameter mm 0,6 1 1 1 1 0,2 0,6 1 0,6
Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare Copper, bare
Insulation mm 2,8 Cell PE 6,4 PE 6,4 PE 6,4 PE 6,4 PE 3,7 PE 3,7 PE 6,4 PE 3,7 PE
1st Outer conductor Polyester foil Bare copper Bare copper Bare copper Bare copper Bare copper Bare copper Bare copper Bare copper braid
coated with braid braid braid braid braid braid braid
aluminium on
both sides
approx. mm - 7 7 7 7 4,2 4,3 7 -
Inner steath/Foil - - PE - Foil - - Foil -
approx. mm - - 8,5 - - - - - -
2nd Outer conductor Tinned copper no Bare copper no Bare copper no no Bare copper -
braid braid braid braid
approx. mm - - 9,1 - 7,6 - - 7,6 -
Outer sheath FRNC PE PVC PVC PE PVC PVC PVC PVC
Sheath colour green black green green black green green green black
Outer approx. mm 4,3 8,8 11,0 8,8 9,0 6,1 6,1 9,0 11,8
Min. bending radius approx. mm 25 45 55 45 50 30 30 50 50
Weight approx. kg / km 24 93 151 95 125 48 48 128 85
Electrical characteristics
Impedance (Ohm) 75 2 75 1 75 1 75 1 75 1 75 1 75 1 75 1 75 3
Attenuation at 20C
(db/100m)
1 MHz 0,9 0,6 0,6 0,6 0,6 1,2 1,1 0,6 1,1
5 MHz 2,2 1,3 1,4 1,3 1,4 2,6 2,5 1,4 2,5
7 MHz 2,6 - - - - - - - -
10 MHz 3,2 2 2 2 2 3,6 3,5 2 3,5
50 MHz 7,5 - - - - - - - -
100 MHz 10,2 - - - - - - - -
Propagation velocity v/c 0,8 0,66 0,66 0,66 0,66 0,66 0,66 0,66 0
DC resistance at 20C
Inner conductor max.Ohm/km 63 22 24 22 24 83 63 24 63
Outer conductor max.Ohm/km 21 7,5 6,5 7,5 3,5 12,5 13 3,5 13
CapacitancepF/m 54 67 67 67 67 67 67 67 67
Test voltage (50 Hz, kVeff.) 3,5 7 7 7 7 4,2 4,2 7 4
Note S
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
ALPR=Polyesterfoil coated with Aluminium on both sides
bl=Bare, bk=Black, Cu=Copper, D=2xbraiding, FRNC=Flame Retardant Non-Corrosive, G=Braid, gn=Green, PE=Polyethylene, PEE=Cell-PE,
PVC=Polyvinylchloride
791
Media Technology
Video
Video cables, multicore
Electrical data
Characteristic impedance: 75 Ohm
Inner conductor resistance, max.: 65 Ohm/km
Technical data
Weight: approx. 178 kg/km
Min. bending radius for laying: 130 mm
Operating temperature range min.: -25C
Operating temperature range max.: +70C
Copper weight: 49,0 kg/km
Application
The multi-core, coaxial HELUKABEL video cable is distinguished by 75 Ohm, cell PE insulation, AL foil and braided shielding, PVC element sheath
and outer sheath. Alternative we also offer a halogen-free and flame-resistant version. As example it is suitable for the parallel transmission of signals
(e.g. RGB).
792
Media Technology
Video
Camera cables
Electrical data
Characteristic impedance: 75 Ohm
Technical data
Weight: approx. 95 kg/km
Min. bending radius for laying: 80 mm
Operating temperature range min.: -30C
Operating temperature range max.: +80C
Copper weight: 55,0 kg/km
Application
The HELUKABEL Triax cable ensures the optimal transmission of image signals. This is possible because of the low attenuation values, thick cross-braided
shielding and an especially rugged outer sheath. For the Flex variant, the PVC inner and outer sheath are replaced by TPE to guarantee greater flexibility.
The Triax cables are primarily used to connect video cameras and image transmission systems and are suitable for mobile use.
793
RENEWABLE ENERGY & TRANSPORTATION
795
CABLES FOR PHOTOVOLTAIC INSTALLATIONS
797
Renewable Energy and Transportation / Cables for Photovoltaic Installations
SOLARFLEX-X PV1-F
Note
Not for direct installation in ground
Version with rodent protection available:
SOLARFLEX-X PV1-F NTS,
confer page 799
Application
The SOLARFLEX-X PV1-F is used for cabling solar modules.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
798
Renewable Energy and Transportation / Cables for Photovoltaic Installations
Application
The SOLARFLEX-X PV1-F NTS version with rodent protection, is used in PV systems mainly in farms and agricultural areas.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
706307 1x4 5,8 38,4 80,0 12 706309 1 x 10 7,5 96,0 152,0 8
706308 1x6 6,5 57,6 106,0 10
799
Renewable Energy and Transportation / Cables for Photovoltaic Installations
Application
The SOLARFLEX-X PV1-F TWIN is used for cabling solar modules.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight app. kg / km cross-sec. dimension weight app. kg / km
mm app. mm kg / km mm app. mm kg / km
707234 2 x 2,5 5,4 x 11,0 50,0 95,0 14 705769 2x6 6,8 x 13,6 120,0 187,0 10
707235 2x4 5,8 x 11,8 80,0 125,0 12 707236 2 x 10 7,8 x 15,8 200,0 254,0 8
800
802
CABLES FOR WIND TURBINES
HELUWIND WK 103k EMV D-T UV-resistant, UL/CSA style 10269/2570 single-core/multicore 809
UV-resistant, UL/CSA style** 10553 / 20234, single-core/multicore 90C
HELUWIND WK 135-Torsion 810
(80C in accordance with UL), suitable for offshore
HELUWIND WK 310-Torsion
UV-resistant, suitable for offshore 813
HELUWIND WK 101 H
0.6/1 kV halogen-free 815
HELUWIND WK Powerline ALU 0.6/1 kV or 1.8/3kV, each also available as robust version 818
803
FUNCTION VIEW - WIND TURBINES
Rotor blade
Gearbox Nacelle
Brake
Generator
Yaw control
Tower
Nacelle
Cable loop
Tower
Tower control system / transformer
Tower base Tower control system / transformer
Medium-voltage level
Foundation
804
SELECTION TABLE - CABLES & WIRES
ce
e
nc
an
da
C
rd
or
co
in
cc
2)
ac
n
t
a
an
tio
U al v h FT
in
ist
i
la
/-
C
ge
ho an res
al
ag
it
+
ic
in
ta
st
(w
V- ve **
E olt
ffs st il-
h
Cu eter ble
in
ol
g
ap
O si o
e
re t
4
n
VD al v
fre
U si nt
ed
a
us
xi
gr
re ly
T
r m on
n
te sta
fle
il- -
fix
F
ith in
ith in
ee
al
O g en
ee
pe rsi
st
st
L
ov
Ex si
w om
w om
cr
p.
p.
,s
te
te
e
n
To
ge
pr
-s
lo
m
N
N
se
e
Ap
Ha
Pa
Fir
Fir
Te
Te
U
Torsion cables
UL 10678/
WK 103w-T 21179, x 1000 V 0.6/1 kV x* x x -40 to +90 -35 to +90 140 808
cRUus, CE
UL 10269,
WK 103w EMV D-T 2570, cRUus, x 1000 V 0.6/1 kV x* x x -40 to +90 -35 to +90 90 808
CE
UL 10269,
WK 103k-T 2570, cRUus, x 1000 V 0.6/1 kV x x -40 to +80 -40 to +80 140 809
CE
UL 10269,
WK 103k EMV D-Torsion 2570, cRUus, x 1000 V 0.6/1 kV x x -40 to +80 -40 to +80 90 809
CE
UL 10553,
WK 135-T 20234, cRUus, 60332-3 1000 V 0.6/1 kV x x x x -40 to +90 -40 to +90 150 810
CE, VDE
UL 10553,
WK 135 EMV D-T 20234, cRUus, 60332-3 1000 V 0.6/1 kV x x x x -40 to +90 -40 to +90 150 810
CE, VDE
UL 10553,
WK 137-T FT4 20234, cRUus, x1 1000 V 0.6/1 kV x x x x -40 to +90 -40 to +90 150 811
CE, VDE
UL 10553,
WK 137 EMV D-T 20234, cRUus, x1 1000 V 0.6/1 kV x x x x -40 to +90 -40 to +90 150 811
CE, VDE
WK 300w-T CE 1.8/3kV x x -40 to +90 -35 to +90 90 812
WK 310-T CE 30332-3 1.8/3kV x x x -40 to +90 -40 to +90 150 813
WK H07BN4-F WIND-T CE 450/750V x -45 to +90 -35 to +90 150 814
WK 101 H CE 0.6/1 kV x x x -50 to +100 -40 to +90 815
WK fire alarm cable-T CE x 24V x x -50 to +90 -40 to +80 215 816
WK NTSCGEWOEU-T CE 3.6/6kV x x -40 to +90 -40 to +90 100 ???
WK DLO 2 kV UL 44, CSA, CE x x 2000 V x -40 to +90 817
WK Powerline ALU 60332-3 0.6/1 kV x x x -40 to +105 -20 to +105 818
WK THERMFLEX 145 CE 0.6/1 kV x x -55 to +145 -20 to +120 819
WK (N)A2XH CE 60332-3 0.6/1 kV x x -30 to +90 -5 to +50 820
Tower & infrastructure cables
NYY-J/-0 CE x 0.6/1 kV -40 to +70 -5 to +50 538
NAYY CE x 0.6/1 kV -40 to +70 -5 to +50 544
NA2XY CE x 0.6/1 kV -40 to +70 -5 to +50 551
N2XH CE x 0.6/1 kV x -30 to +90 -5 to +50 ???
WK (N)A2XH CE 60332-3 0.6/1 kV x x -40 to +90 -5 to +50 820
N2XS2Y 6-30 kV x -40 to +90 x 587
NA2XS2Y 6-30 kV x -40 to +90 x 595
N2XS(F)2Y 6-30 kV x -40 to +90 x 589 T
NA2XS(F)2Y 6-30 kV x -40 to +90 x 597
805
SELECTION TABLE - CABLES & WIRES
ce
e
1
nc
2-
an
da
33
C
rd
or
60
co
in
cc
ac
n
nt
C
tio
IE
ta
in
in
la
sis
o
C
e
ge
st
al
g
re
ic
in
ta
st
d
E olt
-
h
in
on
ol
ng
ap
oi
ns ee
nt
U al v
VD al v
ed
sp
xi
gr
ly
ta
Ex n-f
n
fle
fix
rre
ive
ith in
ith in
al
ee
sis
ee
L
ov
w om
w om
ge
co
cr
p.
p.
re
,s
ge
pr
-s
lo
te
m
V-
N
N
se
1
Ap
Ha
Cu
Pa
FT
Te
Te
U
U
Control cables
JZ-500 CE, VDE x 300/500 V x -40 to +80 -15 to +80 30
F-CY-JZ CE, VDE x 300/500 V x -40 to +80 -40 to +80 50
Y-CY-JZ CE, VDE x 300/500 V -40 to +80 -5 to +80 x 53
JZ-500 HMH CE 60332-3 300/500 V x -40 to +70 -15 to +70 x 86
JZ-500 HMH-C CE 60332-3 300/500 V x -40 to +70 -15 to +70 x 96
MEGAFLEX 500 UL, CSA, CE 60332-3 300/600 V 300/500 V x x x -40 to +80 -30 to +90 x 88
MEGAFLEX 500-C UL, CSA, CE 60332-3 300/600 V 300/500 V x x x -40 to +80 -30 to +90 x 98
JZ-600 CE x 0.6/1 kV x x -40 to +80 -5 to +80 x 40
JZ-600-Y-CY CE x 0.6/1 kV x x -40 to +80 -5 to +80 x 60
Single 600-J/-O UL, CSA, CE x 600 V 0.6/1 kV x -40 to +90 -5 to +90 x 498
Single 600-CY -J/-O UL, CSA, CE x 600 V 0.6/1 kV x -40 to +90 -5 to +90 x 499
JZ-600 HMH CE 60332-3 0.6/1 kV x x x -40 to +70 -15 to +70 x 91
JZ-600 HMH-C CE 60332-3 0.6/1 kV x x x -40 to +70 -5 to +70 x 100
JZ-600 UL/CSA UL, CSA, CE x 1kV 0.6/1 kV x in sw -40 to +80 -5 to +80 x 362
JZ-600-Y-CY-UL/CSA UL, CSA, CE x 1kV 0.6/1 kV x in sw -40 to +80 -5 to +80 x 378
JZ-602 UL, CSA, CE x 600 V x -40 to +90 -5 to +90 x 356
JZ-602-CY UL, CSA, CE x 600 V x -40 to +90 -5 to +90 x 373
UL, CSA,
JZ-603 x 600 V 300/500 V x -40 to +70 -5 to +70 x 358
CE, HAR
UL, CSA,
JZ-603-CY x 600 V 300/500 V x -40 to +70 -5 to +70 x 375
CE, HAR
UL, CSA,
H07RN-F 600 V 450/750 V x -40 to +90 242
CE, HAR
UL, CSA,
H07RN-F/SOOW 600 V 450/750 V x -40 to +90 481
CE, HAR
HELUTHERM 145 MULTI CE 60332-3 300/500 V x x x -55 to +145 -35 to +120 x 221
HELUTHERM 145 MULTI/-C CE 60332-3 450/750 V x x x -55 to +145 -35 to +120 x 230
Data lines
TRONIC-CY CE x 350/500V x -40 to +80 -5 to +80 x 133
PAAR-TRONIC-CY CE x 350/500V x -30 to +80 -5 to +80 x 135
DATAFLAMM CE x 350/500V x -40 to +70 -5 to +70 x 130
DATAFLAMM-C CE x 350/500V x -40 to +70 -5 to +70 x 147
DATAFLAMM-C-PAAR CE x 350/500V x -40 to +70 -5 to +70 x 148
LIYY-UL UL, CSA, CE 300V x -20 to +80 -10 to +80 x 403
LIYY-TP-UL UL, CSA, CE 300V x -20 to +80 -10 to +80 x 407
SUPERTRONIC-PUR CE 350V x -40 to +70 -5 to +70 x 191
SUPERTRONIC-C-PUR CE 350V x -40 to +70 -5 to +70 x 192
SUPERTRONIC -330 PUR
UL, CSA, CE x 300V 300V x x -50 to +80 -40 to +80 x 447
SUPERTRONIC-330-C-PUR UL, CSA, CE x 300V 300V x x -50 to +80 -40 to +80 x 449
SUPER-PAAR-TRONIC-C-PUR UL, CSA, CE x 300V 350V x x -50 to +70 -40 to +70 x 193
SUPER-PAAR-TRONIC 340-C-PUR UL, CSA, CE x 300V 350V x x -50 to +70 -40 to +70 x 451
806
SELECTION TABLE - CABLES & WIRES
ce
e
1
nc
2-
an
da
33
C
rd
or
60
co
in
cc
ac
n
nt
C
tio
IE
ta
in
in
la
sis
o
C
e
ge
st
al
g
re
ic
in
ta
st
d
E olt
-
h
in
on
ol
ng
ap
oi
ns ee
nt
U al v
VD al v
ed
sp
xi
gr
ly
ta
Ex n-f
n
fle
fix
rre
ive
ith in
ith in
al
ee
sis
ee
L
ov
w om
w om
ge
co
cr
p.
p.
re
,s
ge
pr
-s
lo
te
m
V-
N
N
se
1
Ap
Ha
Cu
Pa
FT
Te
Te
U
U
Single cores
H07 V-K/(H)07 V-K CE x x -30 to +80 -5 to +70 291
H05Z-K/H07Z-K CE x x -40 to +90 -5 to +70 300
FIVE APPROVAL UL, CSA, CE x x -40 to +90 -5 to +90 490
HELUTHERM 145 600V UL, CSA, CE x x -55 to +125 -35 to +120 305
HELUTHERM 145 600V UL UL, CSA, CE x x -55 to +125 -35 to +120 496
TC TRAY CABLES USA
TRAYCONTROL 300 UL, CSA, CE FT 4 300V x -25 to +105 -25 to +105 405
TRAYCONTROL 300-C
UL, CSA, CE FT 4 300V x -25 to +105 -25 to +105 x 416
TRAYCONTROL 300-C TP UL, CSA, CE FT 4 300V x -25 to +105 -25 to +105 x 420
UL 1277,
TRAYCONTROL 500 FT 4 1000V x -40 to +90 -5 to +90 359
CSA, CE
UL 1277,
TRAYCONTROL 500-C FT 4 1000V x -40 to +90 -5 to +90 x 376
CSA, CE
UL 1277,
JZ-604 TC TRAY CABLE FT 4 600V x x -25 to +90 -5 to +90 364
CSA, CE
JZ-604-YCY TC TRAY CABLE UL 1277, CSA FT 4 600V x x -25 to +90 -5 to +90 x 381
UL 1277,
TRAYCONTROL 600
FT 4 1000V x x -40 to +90 -5 to +90 366
CSA, CE
Communication cables
Industrial Ethernet 105C UL, CSA, CE 60332-1 300V 100V x x x -40 to +105 -40 to +105 x 693
Industrial Ethernet
UL, CSA, CE 60332-1 300V 100V x x x -20 to +80 -20 to +80 x 697
S-FTP TORDIERFLEX
BUS cable HELUWIND
UL, CSA, CE x 600V 100V x x x -40 to +105 -20 to +60 x ???
WK CAN BUS 105C
BUS cable Indoor UL, CSA, CE x 600V 100V x -40 to +70 -5 to +60 x 717
Profibus SK Outdoor CE 100V x x -40 to +70 -5 to +60 x 717
BUS cable Torsion UL, CMX, CE x 300V 100V x x x -40 to +75 -25 to +75 x 704
Profibus L2 Industry CE x 100V x x x -40 to +70 -5 to +60 x 706
AT-V(ZN)Y(ZN)Y Submitted Submitted x x -40 to +90 -40 to +90 638
AT-V(ZN)H(ZN)11Y x x x -40 to +90 -40 to +90 638
Fiber-optic cable, mobile,
easy-to-wind 60332-1 x x x -30 to +70 -20 to +70 636
A-V(ZN)11Y
Fiber-optic cable mobile
UL, CSA FT4 x x -30 to +80 -20 to +80 637
A-V(ZN)Y
Fiber optic breakout cable
UL, CSA FT4 x x -30 to +85 -20 to +85 644
Industry HCS I-V(ZN)YY
Fiber optic breakout cable
x x -20 to +80 -20 to +80 645
Industry HCS I-V(ZN)Y11Y
Plastic fiber cable Industry
60332-1 x x -20 to +80 -20 to +80 648
POF/PE I-V2Y, I-V2Y(ZN)11Y
Fiber optic universal cable
T
60332-1 x x x -20 to +60 -5 to +50 613
A/I-DQ(ZN)BH
Fiber optic outdoor cable
x -20 to +60 -5 to +50 619
A-DQ(ZN)B2Y (central)
Fiber optic outdoor cable
x -20 to +60 -5 to +50 620
A-DQ(ZN)B2Y (stranded)
Fiber optic outdoor cable
A-DQ(ZN)B2Y x -20 to +60 -5 to +50 625
(Stranded, fiber combination)
807
Renewable Energy and Transportation / Cables for Wind Turbines
HELUWIND WK 103w-T,
WK 103w EMV D-T UV-resistant, UL/CSA-Style 10678/21179
Single-/Multicore
Application
The WK 103w has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The voltage level has been
configured as 0. 6/1 kV for all dimensions, which means that the cables can also be laid in parallel in compliance with UL standards. It is no longer
necessary to separate the cable routes. The WK series has been successfully tested with more than 18,000 torsion cycles and thus offers optimum
operational reliability far beyond the service life of the wind power plant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.
808
Renewable Energy and Transportation / Cables for Wind Turbines
Application
The WK 103k has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The voltage level has been
configured as 0. 6/1 kV for all dimensions, which means that the cables can also be laid in parallel in compliance with UL standards. It is no longer
necessary to separate the cable routes. The WK series has been successfully tested with more than 18,000 torsion cycles and thus offers optimum
operational reliability far beyond the service life of the wind power plant.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC..
Dimensions and specifications may be changed without prior notice.
809
Renewable Energy and Transportation / Cables for Wind Turbines
HELUWIND WK 135-T,
WK 135 D-EMV T UV-resistant, UL/CSA-Style** 10553
/ 20234, Single-/Multicore 90C (80C acc. to UL), suitable for offshore
Application
The WK 135 has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The voltage level has been
configured as 0. 6/1 kV for all dimensions, which means that the cables can also be laid in parallel in compliance with UL standards. It is no longer
necessary to separate the cable routes. Thanks to its highly durable sheath and absence of halogen, this cable is ideal for use in offshore wind power
plants. The WK series has been successfully tested with more than 18,000 torsion cycles and thus offers optimum operational reliability far beyond
the service life of the wind power plant. Advantages of WK 135-T over H07BN4-F: Fire behaviour in accordance with IEC 60332-3-24 Increased
wear resistance Recyclable
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.
810
Renewable Energy and Transportation / Cables for Wind Turbines
HELUWIND WK 137-T /
WK 137 EMV D-TFT 4 UV-resistant, suitable for
offshore, UL/CSA-Style 10553/20234, Single-/Multicore, 90C, (80C
according to UL)
Application
The WK 137 has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The voltage level has been
configured as 0. 6/1 kV for all dimensions, which means that the cables can also be laid in parallel in compliance with UL standards. It is no longer
necessary to separate the cable routes. Additionally, this cable meets the strict requirements of CSA flame test FT4 and, thanks to its highly durable
sheath and absence of halogen, is ideal for use in offshore wind power plants. The WK series has been successfully tested with more than 18,000
torsion cycles and thus offers optimum operational reliability far beyond the service life of the wind power plant. Advantages of WK 137-T FT4 over
H07BN4-F: Fire behaviour in accordance with IEC 60332-3-24 and FT4 Increased wear resistance
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.
T
Suitable accessories can be found in Chapter X.
Cable lug
811
Renewable Energy and Transportation / Cables for Wind Turbines
Application
The WK 300w has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The WK series has been
successfully tested with more than 18,000 torsion cycles and thus offers optimum operational reliability far beyond the service life of the wind power
plant. Another special feature is the higher voltage level of 1.8/3 kV. The WK 300w is also designed for flexible installation through ductwork and in
the ground. It can be used in power cabling from a converter cabinet to an external transformer station, for example. A conductor temperature of
+90 enables a high level of current carrying capacity.
Dimensions and specifications may be changed without prior notice.
812
Renewable Energy and Transportation / Cables for Wind Turbines
Application
The WK 310 has been designed for flexible use, and specifically for torsional load in the cable loop of a wind power plant. The WK series has been
successfully tested with more than 18,000 torsion cycles and thus offers optimum operational reliability far beyond the service life of the wind power
plant. Another special feature is the higher voltage level of 1.8/3 kV. The WK 310 can be used instead of the WK 300 in cases where cables need to
be halogen-free.
Dimensions and specifications may be changed without prior notice.
813
Renewable Energy and Transportation / Cables for Wind Turbines
Application
The HELUWIND WK H07BN4-F Wind-Torsion cable is the special version for torsion applications in wind power plants. We supply the leading wind
power plant manufacturers with our cables.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.
814
Renewable Energy and Transportation / Cables for Wind Turbines
Application
The HELUWIND WK series has been specifically designed for use in wind power plants. These cables are used in cases that require extremely narrow
bending radii and high current carrying capacity levels (+90C conductor temperature).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC..
Dimensions and specifications may be changed without prior notice.
815
Renewable Energy and Transportation / Cables for Wind Turbines
Application
This fire alarm cable has been specifically developed for torsion applications in wind power plant loops. We supply the leading wind power plant
manufacturers with our cables.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.
816
Renewable Energy and Transportation / Cables for Wind Turbines
Application
The cable is UL 44 listed. The WK DLO is a flexible cable for continuous tower cabling in wind power plants, right up to the topmost tower segment.
For the torsion cable through the cable loop to the generator in the nacelle, we recommend the WK 103 or WK 135.
Dimensions and specifications may be changed without prior notice.
817
Renewable Energy and Transportation / Cables for Wind Turbines
Application
The WK Powerline ALU is a highly flexible aluminium cable with a finely stranded structure and is designed for use in the power engineering sector;
specifically, for power cabling in wind power plants. Thanks to its high degree of flexibility and low tare weight, this cable can be fed into the tower
as a single length. This eliminates the need for time-consuming cabling of each individual tower segment. However, its key advantage lies in the process
reliability the connection technology offers: using this cable can reduce the number of interruptions between the topmost tower segment and the
converter from 90 connection points to just 18 (depending on the number of power cables and tower segments). As a result, the amount of time
required for installation can drop from several days to a few hours. For torsion applications, we recommend the WK 103-T, WK 135-T or WK 137-T.
The WK Powerline ALU may only be used with certified connection technology from HELUKABEL: either C8 crimp connections or screwed connections
(tested in accordance with IEC 61238-1 Cl. A). See the accessories section of the catalogue. The cable is also available with a halogen-free design,
UL/CSA approval or a rated voltage of 1. 8/3 kV.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.
818
Renewable Energy and Transportation / Cables for Wind Turbines
Application
This special cable can be used as a generator connecting cable in wind power plants, for example. Other areas of application: Connecting cable for
temperature class B (130C) in the case of motors, transformers, relays, coils, magnets, and so onUnit connections in the automotive industry.
Halogen-free wiring of switchgear and control cabinets. Connecting cable for heating equipment. Supply line for high-power lighting in industry,
sports centres and street lighting
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.
819
Renewable Energy and Transportation / Cables for Wind Turbines
Application
The HELUWIND WK series was specifically designed for wind power applications. We supply the leading wind turbine manufacturers with our cables.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Dimensions and specifications may be changed without prior notice.
820
Cavotec
CABLES FOR AIRCRAFT SUPPLY
823
Renewable Energy and Transportation / Cables for Aircraft feeder lines
Application
400 Hz cables are used to supply power to aircraft (on-board power), data processing systems, radar stations, radio stations, etc. For safety reasons,
400 Hz cables are used to connect data processing systems, radar systems and communications systems to uninterruptible power supplies. Such
power supplies prevent a total failure of power and compensate for frequency and voltage fluctuations. Suitable for installation indoors, outdoors.
Applications: Below floor level cable dispensers (drums), attached to jetways and retractable articulated cable carries.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
700573 7 x 25 + 6 x 4 x 1,0 41,0 1910,0 2140,0 4 702801 7 G 35 35,8 2746,0 3050,0 2
770009 7 x 35 + 6 x 4 x 1,0 42,5 2625,0 2950,0 2
700574 7 x 50 + 6 x 4 x 1,0 51,0 3590,0 4030,0 1
824
Renewable Energy and Transportation / Cables for Aircraft feeder lines
Application
400 Hz cables are used to supply power to aircraft (on-board power), data processing systems, radar stations, radio stations, etc. For safety reasons,
400 Hz cables are used to connect data processing systems, radar systems and communications systems to uninterruptible power supplies. Such
power supplies prevent a total failure of power and compensate for frequency and voltage fluctuations. Suitable for installation indoors, outdoors.
Highly flexible, and can thus be plugged directly into the connector in the aircraft without an adapter, and without endangering the contacts.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
700566 1 x 35 11,5 336,0 430,0 2 700571 4 x 1 x 35 + 4 x 1,0 33,0 1498,0 2600,0 2
700570 1 x 35 + 4 x 1,0 16,1 375,0 490,0 2 770005 4 x 1 x 50 + 4 x 1,0 40,0 2074,0 3900,0 1
700567 1 x 50 12,6 480,0 665,0 1 770004 4 x 1 x 70 + 4 x 1,0 49,2 2844,0 4300,0 2/0
770001 1 x 50 + 4 x 1,0 17,0 519,0 600,0 1 700572 4 x 1 x 120 + 4 x 1,0 56,0 4765,0 7400,0 4/0
700568 1 x 70 14,0 672,0 910,0 2/0
770002 1 x 70 + 4 x 1,0 20,5 711,0 800,0 2/0
700569 1 x 120 23,0 1152,0 1545,0 4/0
770003 1 x 120 + 4 x 1,0 25,0 1191,0 1400,0 4/0
825
CABLES FOR COMMERCIAL VEHICLES
HELUTRUCK 270
with ADR approval, PVC, low-voltage cable for commercial vehicles 828
HELUTRUCK 271 with ADR approval, PUR, low-voltage cable for commercial vehicles 829
HELUTRUCK 272
with ADR approval, ribbon cable for side marker lights 830
HELUTRUCK 273 Battery cable, battery charging cable, twin cable 831
827
Renewable Energy and Transportation / Cables for Commercial Vehicles
HELUTRUCK 270 (FLRYY) with ADR-approval, PVC low voltage cable for
commercial vehicles
Note
Further sizes are available on request.
Application
These low-voltage cables are designed for the wiring of electrical installations in the manufacture of commercial vehicles. Due to the ADR-approval
especially suitable for trailers and semitrailers manufactured for the transport of GGVS hazardous substances.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
700016 2 x 0,5 4,8 9,6 40,0 20 700579 4 x 1,5 7,5 57,6 106,0 16
700575 2 x 0,75 + 2 x 1,5 7,0 43,2 91,0 18 700407 8 x 1,5 + 1 x 2,5 11,5 139,2 238,0 16
702179 3 x 0,75 5,3 21,6 52,4 17 75262 6 x 1,5 + 1 x 2,5 10,3 110,5 187,0 16
700582 7 x 0,75 7,3 50,4 101,0 18 700032 7 x 1,5 10,3 100,8 185,0 16
75255 2x1 6,0 19,2 56,0 17 75261 7 x 1,5 8,9 100,2 165,0 16
75254 2x1 6,0 19,2 56,0 17 75263 8 x 1,5 + 1 x 2,5 11,7 139,2 238,0 16
75256 3x1 6,3 28,8 66,0 17 700583 8 x 1,5 + 5 x 2,5 14,8 235,2 360,0 16
700578 3 x 1 6,6 28,8 66,0 17 75267 9 x 1,5 + 4 x 2,5 14,8 200,0 350,0 16
75257 4x1 6,8 38,4 80,0 17 75265 10 x 1,5 + 3 x 2,5 12,5 168,0 366,0 16
75258 5x1 7,5 48,0 98,0 17 75319 10 x 1,5 + 3 x 2,5 + 2 x 1,5 14,4 244,8 393,0 16
75260 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 700017 10 x 1,5 + 3 x 2,5 + 2 x 1,5 14,3 244,8 391,0 16
700580 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 705167 10 x 1,5 + 3 x 2,5 + 2 x 1,5 14,4 244,8 393,0 16
75259 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 75266 10 x 1,5 + 3 x 2,5 13,0 216,0 345,0 16
700581 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 700018 11 x 1,5 + 3 x 2,5 13,5 230,4 365,0 16
700849 5 x 1 + 1 x 2,5 9,3 65,7 149,5 16 700142 3 x 2,5 + 4 x 1,5 10,3 129,6 221,0 14
700576 2 x 1,5 6,6 28,8 66,0 16 706627 4 x 6 + 1 x 1,5 13,7 244,8 411,0 18
700577 2 x 1,5 6,6 28,8 66,0 16
828
Renewable Energy and Transportation / Cables for Commercial Vehicles
Note
Further sizes are available on request.
Application
These low-voltage cables are designed for the wiring of electrical installations in the manufacture of commercial vehicles. Due to the ADR-approval
especially suitable for trailers and semitrailers manufactured for the transport of GGVS hazardous substances.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. cross-sec. app. mm weight app.
mm kg / km kg / km mm kg / km kg / km
708090 9 x 0,5 + 4 x 2,5 + 2 x 0,5 12,0 148,0 490,0 16 700587 2 x 1,5 6,6 28,8 67,0 16
709556 2 x 0,75 5,4 14,4 45,8 18 700589 4 x 1,5 7,5 57,6 105,0 16
700585 2 x 0,75 + 2 x 1,5 7,0 43,2 91,0 18 75536 6 x 1,5 + 1 x 2,5 10,3 110,4 187,0 16
700592 7 x 0,75 7,9 50,4 100,0 18 75535 7 x 1,5 8,9 100,8 165,0 16
75528 2x1 6,0 19,0 56,0 17 75537 8 x 1,5 + 1 x 2,5 11,7 139,2 238,0 16
75529 2x1 6,0 19,0 56,0 17 75539 10 x 1,5 + 3 x 2,5 14,4 214,0 366,0 16
75530 3x1 6,3 28,8 66,0 17 700594 10 x 1,5 + 3 x 2,5 14,4 214,0 366,0 16
700588 3 x 1 6,3 28,8 66,0 17 75538 10 x 1,5 + 3 x 2,5 + 2 x 1,5 14,4 244,8 393,0 16
75531 4x1 6,8 38,5 80,0 17 700595 18 x 1,5 17,0 259,2 520,0 16
75532 5x1 7,5 48,1 98,0 17 700596 25 x 1,5 19,9 360,0 730,0 16
700591 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 701045 2 x 2,5 7,6 48,0 104,9 16
75533 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 701044 2 x 2,5 + 5 x 1,5 10,3 120,0 214,4 16
700590 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 75932 2 x 4 + 3 x 1,5 + 2 x 1,5 12,0 148,8 230,0 12
75534 5 x 1 + 1 x 2,5 9,0 72,0 132,0 17 75541 2 x 6 + 3 x 1,5 + 2 x 1,5 12,0 187,2 320,0 10
705135 7 x 1 8,6 68,0 133,1 17 75540 2 x 6 + 3 x 1,5 12,0 158,6 270,0 10
700586 2 x 1,5 6,6 28,8 67,0 16
829
Renewable Energy and Transportation / Cables for Commercial Vehicles
HELUTRUCK 272 (FLRYYF) with ADR-approval, flat cable for the sideways
lighting
Note
Further sizes are available on request.
Application
This low-voltage cable is designed for the wiring of electrical installations in the manufacture of commercial vehicles. Especially suitable for trailers
and semitrailers. This flat cable can be used for simple and quick contacting of sidelights by means of core penetration. Its flat construction and the
special contacting method eliminate the need for time-consuming assembly of cables. This facilitates quick installation, making it possible to save a
great deal of time. ADR approval for transport of hazardous substances by trailers and semitrailers.
HELUTRUCK 272
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight app.
mm app. mm kg / km kg / km
76706 2 x 1,5 4,5 x 6,8 28,8 90,0 16
700035 2 x 1,5 4,5 x 6,8 28,8 90,0 16
78983 2 x 1,5 4,5 x 6,8 28,8 90,0 16
830
Renewable Energy and Transportation / Cables for Commercial Vehicles
Note
Further sizes are available on request.
Application
This battery cable can be used between the battery and the ultimate consumer (e.g. DC motor of the tail-lift).
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
HELUTRUCK 273
Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. dimension weight app. kg / km
mm app. mm kg / km
75507 2 x 2,5 5,6 x 28,8 48,0 87,0 14
75508 2x4 6,6 x 14,8 77,0 125,0 12
75509 2x6 6,8 x 14,6 116,0 175,0 10
75510 2 x 10 8,1 x 17,2 192,0 270,0 8
75511 2 x 16 8,9 x 18,5 308,0 390,0 6
75512 2 x 25 10,7 x 21,7 480,0 575,0 4
75513 2 x 35 12,8 x 26,6 672,0 820,0 2
75514 2 x 50 14,1 x 29,2 960,0 1065,0 1
709043 2 x 70 16,1 x 33,2 1344,0 1475,0 2/0
831
CABLES FOR TRAIN & TRAFFIC
HELUTRAIN 3GKW
train cable, robust special core cable, halogen-free 0.6/1 kV 834
HELUTRAIN 4GKW-AXplus single-core train cable, robust halogen-free, 1.8/3kV meter marking 835
Vehicle cable FLY one colour / two color /old type FLK), in accordance with DIN ISO 6722 836
Vehicle cable FLY one colour / two color /old type FLK), in accordance with DIN ISO 6722 837
Vehicle cable FLY one colour / two color /old type FLK), in accordance with DIN ISO 6722 838
833
Renewable Energy and Transportation / Cables for Trains
Application
HELUTRAIN 3 GKW train cable are Halogen-free and suitable for fixed and protected installation in rough environmental conditions inside and outside
of rail vehicles. For connecting fixed and moving parts. Due to the flexibility and the small outer diameter suitable for fixed installation in small bending
radii.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC..
Core colour grey Core colour green-yellow
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
59114 1 x 0,5 2,0 4,8 9,0 - 53762 1 x 0,5 2,0 4,8 9,0 -
59115 1 x 0,75 2,2 7,2 12,0 - 53763 1 x 0,75 2,2 7,2 12,0 -
59116 1x1 2,4 9,6 14,0 - 53764 1x1 2,4 9,6 14,0 -
59117 1 x 1,5 2,7 14,4 21,0 - 53765 1 x 1,5 2,7 14,4 21,0 -
59118 1 x 2,5 3,4 24,0 31,0 - 53766 1 x 2,5 3,4 24,0 31,0 -
59119 1x4 3,9 38,4 46,0 - 53767 1x4 3,9 38,4 46,0 -
59126 1x6 4,6 57,6 68,0 - 53768 1x6 4,6 57,6 68,0 -
59127 1 x 10 5,5 96,0 111,0 - 53769 1 x 10 5,5 96,0 111,0 -
59128 1 x 16 7,1 154,0 166,0 - 53770 1 x 16 7,1 154,0 166,0 -
59129 1 x 25 8,6 240,0 250,0 - 53771 1 x 25 8,6 240,0 250,0 -
59130 1 x 35 9,8 336,0 350,0 - 53772 1 x 35 9,8 336,0 350,0 -
59131 1 x 50 12,0 480,0 500,0 - 53773 1 x 50 12,0 480,0 500,0 -
59132 1 x 70 14,2 672,0 690,0 - 53774 1 x 70 14,2 672,0 690,0 -
59133 1 x 95 15,6 912,0 940,0 - 53775 1 x 95 15,6 912,0 940,0 -
59134 1 x 120 17,6 1152,0 1180,0 - 53776 1 x 120 17,6 1152,0 1180,0 -
59135 1 x 150 20,3 1440,0 1460,0 - 53777 1 x 150 20,3 1440,0 1460,0 -
834
Renewable Energy and Transportation / Cables for Trains
Note
screened analogue type
part no. 54092
HELUTRAIN-C 4GKW 1x35
Application
For fixed installation inside and outside of unprotected rail cars and buses. For connecting fixed and moving parts.
Suitable for wiring of switchboards, distribution boards, power converters, electrical panels and blocks, resistor and brake blocks. T
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. app. mm weight app. kg / km cross-sec. app. mm weight app. kg / km
mm kg / km mm kg / km
59262 1 x 1,5 3,6 14,4 24,0 - 59312 1 x 50 13,6 480,0 536,0 -
59263 1 x 2,5 4,0 24,0 34,0 - 59313 1 x 70 16,0 672,0 729,0 -
59264 1x4 4,9 38,4 53,0 - 59314 1 x 95 17,5 912,0 960,0 -
59265 1x6 5,5 57,6 74,0 - 59315 1 x 120 20,0 1152,0 1203,0 -
59266 1 x 10 6,5 96,0 118,0 - 59316 1 x 150 22,0 1440,0 1464,0 -
59267 1 x 16 8,7 153,6 182,0 - 59317 1 x 185 24,1 1776,0 1802,0 -
59268 1 x 25 10,2 240,0 274,0 - 59318 1 x 240 26,8 2304,0 2348,0 -
59269 1 x 35 11,5 336,0 379,0 -
835
Renewable Energy and Transportation / Cables for Commercial Vehicles
Vehicle Cable FLY one colour / two colour (old type FLK), according to DIN ISO 6722
Application
PVC insulated single core cables are used for vehicle constructions.
one colour
Cross- Outer Cop. Weight BK BU BN RD WH GY VT YE PK GN OG
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 29800 40217 40243 40282 40204 40321 40269 40308 40295 40256 40230
0,5 2,0 - 2,3 4,8 9,0 - - - - - - - - - - -
Part no. 29801 40218 40244 40283 40205 40322 40270 40309 40296 40257 40231
0,75 2,2 - 2,5 7,2 12,0 - - - - - - - - - - -
Part no. 29802 40219 40245 40284 40206 40323 40271 40310 40297 40258 40232
1 2,4 - 2,7 9,6 15,0 - - - - - - - - - - -
Part no. 29803 40220 40246 40285 40207 40324 40272 40311 40298 40259 40233
1,5 2,7 - 3,0 14,4 20,0 - - - - - - - - - - -
Part no. 29804 40221 40247 40286 40208 40325 40273 40312 40299 40260 40234
2,5 3,3 - 3,6 24,0 32,0 - - - - - - - - - - -
Part no. 29805 40222 40248 40287 40209 40326 40274 40313 40300 40261 40235
4 4,0 - 4,4 38,4 48,0 - - - - - - - - - - -
Part no. 29806 40223 40249 40288 40210 40327 40275 40314 40301 40262 40236
6 4,6 - 5,0 57,6 68,0 - - - - - - - - - - -
Part no. 29807 40224 40250 40289 40211 40328 40276 40315 40302 40263 40237
10 6,0 - 6,5 96,0 117,0 - - - - - - - - - - -
Part no. 29808 40225 40251 40290 40212 40329 40277 40316 40303 40264 40238
16 7,0 - 8,3 154,0 189,0 - - - - - - - - - - -
Part no. 29809 40226 40252 40291 40213 40330 40278 40317 40304 40265 40239
25 9,4 - 10,4 240,0 288,0 - - - - - - - - - - -
Part no. 29810 40227 40253 40292 40214 40331 40279 40318 40305 40266 40240
35 10,8 - 11,6 336,0 382,0 - - - - - - - - - - -
Part no. 29811 40228 40254 40293 40215 40332 40280 40319 40306 40267 40241
50 12,5 - 13,5 480,0 540,0 - - - - - - - - - - -
Part no. 29812 40229 40255 40294 40216 40333 40281 40320 40307 40268 40242
70 14,5 - 15,5 672,0 744,0 - - - - - - - - - - -
836
Renewable Energy and Transportation / Cables for Commercial Vehicles
Vehicle Cable FLY one colour / two colour (old type FLK), according to DIN ISO 6722
two colour
Cross- Outer Cop. Weight WH/GY WH/RD WH/BN WH/BU WH/BK YE/GY YE/RD YE/BN YE/BU YE/BK
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 40334 40347 40360 40373 40386 40399 40412 40425 40438 40451
0,5 2,0 - 2,3 4,8 9,0 - - - - - - - - - -
Part no. 40335 40348 40361 40374 40387 40400 40413 40426 40439 40452
0,75 2,2 - 2,5 7,2 12,0 - - - - - - - - - -
Part no. 40336 40349 40362 40375 40388 40401 40414 40427 40440 40453
1 2,4 - 2,7 9,6 15,0 - - - - - - - - - -
Part no. 40337 40350 40363 40376 40389 40402 40415 40428 40441 40454
1,5 2,7 - 3,0 14,4 20,0 - - - - - - - - - -
Part no. 40338 40351 40364 40377 40390 40403 40416 40429 40442 40455
2,5 3,3 - 3,6 24,0 32,0 - - - - - - - - - -
Part no. 40339 40352 40365 40378 40391 40404 40417 40430 40443 40456
4 4,0 - 4,4 38,4 48,0 - - - - - - - - - -
Part no. 40340 40353 40366 40379 40392 40405 40418 40431 40444 40457
6 4,6 - 5,0 57,6 68,0 - - - - - - - - - -
Part no. 40341 40354 40367 40380 40393 40406 40419 40432 40445 40458
10 6,0 - 6,5 96,0 117,0 - - - - - - - - - -
Part no. 40342 40355 40368 40381 40394 40407 40420 40433 40446 40459
16 7,0 - 8,3 154,0 189,0 - - - - - - - - - -
Part no. 40343 40356 40369 40382 40395 40408 40421 40434 40447 40460
25 9,4 - 10,4 240,0 288,0 - - - - - - - - - -
Part no. 40344 40357 40370 40383 40396 40409 40422 40435 40448 40461
35 10,8 - 11,6 336,0 382,0 - - - - - - - - - -
Part no. 40345 40358 40371 40384 40397 40410 40423 40436 40449 40462
50 12,5 - 13,5 480,0 540,0 - - - - - - - - - -
Part no. 40346 40359 40372 40385 40398 40411 40424 40437 40450 40463
70 14,5 - 15,5 672,0 744,0 - - - - - - - - - -
two colour
Cross- Outer Cop. Weight GY/GN GY/RD GY/BN GY/BK GN/WH GN/GY GN/BN GN/BU GN/BK
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 40464 40477 40490 40802 40503 40516 40529 40542 40555
0,5 2,0 - 2,3 4,8 9,0 - - - - - - - - -
Part no. 40465 40478 40491 40803 40504 40517 40530 40543 40556
0,75 2,2 - 2,5 7,2 12,0 - - - - - - - - -
Part no. 40466 40479 40492 40804 40505 40518 40531 40544 40557
1 2,4 - 2,7 9,6 15,0 - - - - - - - - -
Part no. 40467 40480 40493 40805 40506 40519 40532 40545 40558
1,5 2,7 - 3,0 14,4 20,0 - - - - - - - - -
Part no. 40468 40481 40494 40806 40507 40520 40533 40546 40559
2,5 3,3 - 3,6 24,0 32,0 - - - - - - - - -
Part no. 40469 40482 40495 40807 40508 40521 40534 40547 40560
4 4,0 - 4,4 38,4 48,0 - - - - - - - - -
Part no. 40470 40483 40496 40808 40509 40522 40535 40548 40561
6 4,6 - 5,0 57,6 68,0 - - - - - - - - -
Part no. 40471 40484 40497 40809 40510 40523 40536 40549 40562
10 6,0 - 6,5 96,0 117,0 - - - - - - - - -
Part no. 40472 40485 40498 40810 40511 40524 40537 40550 40563
16 7,0 - 8,3 154,0 189,0 - - - - - - - - -
Part no. 40473 40486 40499 40811 40512 40525 40538 40551 40564
25 9,4 - 10,4 240,0 288,0 - - - - - - - - -
Part no. 40474 40487 40500 40812 40513 40526 40539 40552 40565
35 10,8 - 11,6 336,0 382,0 - - - - - - - - -
Part no. 40475 40488 40501 40813 40514 40527 40540 40553 40566
50 12,5 - 13,5 480,0 540,0 - - - - - - - - -
Part no. 40476 40489 40502 40814 40515 40528 40541 40554 40567
70 14,5 - 15,5 672,0 744,0 - - - - - - - - -
837
Renewable Energy and Transportation / Cables for Commercial Vehicles
Vehicle Cable FLY one colour / two colour (old type FLK), according to DIN ISO 6722
two colour
Cross- Outer Cop. Weight RD/WH RD/YE RD/GY RD/GN RD/BU RD/BK BN/WH BN/YE BN/GN BN/BK
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 40568 40581 40594 40607 40620 40633 40646 40659 40672 40685
0,5 2,0 - 2,3 4,8 9,0 - - - - - - - - - -
Part no. 40569 40582 40595 40608 40621 40634 40647 40660 40673 40686
0,75 2,2 - 2,5 7,2 12,0 - - - - - - - - - -
Part no. 40570 40583 40596 40609 40622 40635 40648 40661 40674 40687
1 2,4 - 2,7 9,6 15,0 - - - - - - - - - -
Part no. 40571 40584 40597 40610 40623 40636 40649 40662 40675 40688
1,5 2,7 - 3,0 14,4 20,0 - - - - - - - - - -
Part no. 40572 40585 40598 40611 40624 40637 40650 40663 40676 40689
2,5 3,3 - 3,6 24,0 32,0 - - - - - - - - - -
Part no. 40573 40586 40599 40612 40625 40638 40651 40664 40677 40690
4 4,0 - 4,4 38,4 48,0 - - - - - - - - - -
Part no. 40574 40587 40600 40613 40626 40639 40652 40665 40678 40691
6 4,6 - 5,0 57,6 68,0 - - - - - - - - - -
Part no. 40575 40588 40601 40614 40627 40640 40653 40666 40679 40692
10 6,0 - 6,5 96,0 117,0 - - - - - - - - - -
Part no. 40576 40589 40602 40615 40628 40641 40654 40667 40680 40693
16 7,0 - 8,3 154,0 189,0 - - - - - - - - - -
Part no. 40577 40590 40603 40616 40629 40642 40655 40668 40681 40694
25 9,4 - 10,4 240,0 288,0 - - - - - - - - - -
Part no. 40578 40591 40604 40617 40630 40643 40656 40669 40682 40695
35 10,8 - 11,6 336,0 382,0 - - - - - - - - - -
Part no. 40579 40592 40605 40618 40631 40644 40657 40670 40683 40696
50 12,5 - 13,5 480,0 540,0 - - - - - - - - - -
Part no. 40580 40593 40606 40619 40632 40645 40658 40671 40684 40697
70 14,5 - 15,5 672,0 744,0 - - - - - - - - - -
two colour
Cross- Outer Cop. Weight BU/WH BU/YE BU/GN BU/RD BK/WH BK/YE BK/GN BK/RD
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 40698 40711 40724 40737 40750 40763 40776 40789
0,5 2,0 - 2,3 4,8 9,0 - - - - - - - -
Part no. 40699 40712 40725 40738 40751 40764 40777 40790
0,75 2,2 - 2,5 7,2 12,0 - - - - - - - -
Part no. 40700 40713 40726 40739 40752 40765 40778 40791
1 2,4 - 2,7 9,6 15,0 - - - - - - - -
Part no. 40701 40714 40727 40740 40753 40766 40779 40792
1,5 2,7 - 3,0 14,4 20,0 - - - - - - - -
Part no. 40702 40715 40728 40741 40754 40767 40780 40793
2,5 3,3 - 3,6 24,0 32,0 - - - - - - - -
Part no. 40703 40716 40729 40742 40755 40768 40781 40794
4 4,0 - 4,4 38,4 48,0 - - - - - - - -
Part no. 40704 40717 40730 40743 40756 40769 40782 40795
6 4,6 - 5,0 57,6 68,0 - - - - - - - -
Part no. 40705 40718 40731 40744 40757 40770 40783 40796
10 6,0 - 6,5 96,0 117,0 - - - - - - - -
Part no. 40706 40719 40732 40745 40758 40771 40784 40797
16 7,0 - 8,3 154,0 189,0 - - - - - - - -
Part no. 40707 40720 40733 40746 40759 40772 40785 40798
25 9,4 - 10,4 240,0 288,0 - - - - - - - -
Part no. 40708 40721 40734 40747 40760 40773 40786 40799
35 10,8 - 11,6 336,0 382,0 - - - - - - - -
Part no. 40709 40722 40735 40748 40761 40774 40787 40800
50 12,5 - 13,5 480,0 540,0 - - - - - - - -
Part no. 40710 40723 40736 40749 40762 40775 40788 40801
70 14,5 - 15,5 672,0 744,0 - - - - - - - -
838
Renewable Energy and Transportation / Cables for Commercial Vehicles
Application
PVC insulated single core cables are used for vehicle constructions.
FLRY - Type A (FLK-R)
Cross- Outer Cop. Weight BK BU BN RD WH GY VT YE PK GN OG
sec. min. - max. weight app. kg / km
mm kg / km
Part no. 28484 28486 28488 28491 28485 28494 28490 28493 28492 28489 28487
0,35 1,2 - 1,3 3,4 4,5 - - - - - - - - - - -
Part no. 28495 28497 28499 28502 28496 28505 28501 28504 28503 28500 28498
0,5 1,4 - 1,6 4,8 6,6 - - - - - - - - - - -
839
PRE-ASSEMBLED CABLES
ROBOFLEX-recycle 878
841
842
SERVO MOTOR, FEEDBACK & FAN CABLES
843
Pre-assembled Cables / Servo motor, feedback and fan cables
844
Pre-assembled Cables / Servo motor, feedback and fan cables
845
Pre-assembled Cables / Servo motor, feedback and fan cables
846
Pre-assembled Cables / Servo motor, feedback and fan cables
U
Dimensions and specifications may be changed without prior notice.
847
Pre-assembled Cables / Servo motor, feedback and fan cables
848
Pre-assembled Cables / Servo motor, feedback and fan cables
849
Pre-assembled Cables / Servo motor, feedback and fan cables
850
Pre-assembled Cables / Servo motor, feedback and fan cables
851
Pre-assembled Cables / Servo motor, feedback and fan cables
852
Pre-assembled Cables / Servo motor, feedback and fan cables
U
IKG4063 motor cable 4063 PUR 660108 IKG4204 motor cable 4204 PUR 660146
IKG4070 motor cable 4070 PUR 660109 IKG4223 motor cable 4223 PUR 660149
IKG4068 motor cable 4068 PUR 660110 IKG4224 motor cable 4224 PUR 660150
IKG4067 motor cable 4067 PUR 660111 IKG4013 motor cable 4013 PUR 660153
IKG4083 motor cable 4083 PUR 660114 IKG4020 motor cable 4020 PUR 660154
IKG4090 motor cable 4090 PUR 660115 IKG4018 motor cable 4018 PUR 660155
IKG4087 motor cable 4087 PUR 660116 IKG4016 motor cable 4016 PUR 660156
IKG4103 motor cable 4103 PUR 660119 IKG4033 motor cable 4033 PUR 660157
IKG4110 motor cable 4110 PUR 660120 IKG4050 motor cable 4050 PUR 660158
IKG4107 motor cable 4107 PUR 660121 IKG4035 motor cable 4035 PUR 660159
IKG4123 motor cable 4123 PUR 660124 IKG4037 motor cable 4037 PUR 660160
Continuation
853
Pre-assembled Cables / Servo motor, feedback and fan cables
854
Pre-assembled Cables / Servo motor, feedback and fan cables
855
Pre-assembled Cables / Servo motor, feedback and fan cables
856
Pre-assembled Cables / Servo motor, feedback and fan cables
857
Pre-assembled Cables / Servo motor, feedback and fan cables
858
Pre-assembled Cables / Servo motor, feedback and fan cables
Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.
859
Pre-assembled Cables / Servo motor, feedback and fan cables
860
Pre-assembled Cables / Servo motor, feedback and fan cables
Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.
861
Pre-assembled Cables / Servo motor, feedback and fan cables
Note
Please observe the installation instructions
for laying cables in cable carriers and
the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.
862
Pre-assembled Cables / Servo motor, feedback and fan cables
863
Pre-assembled Cables / Servo motor, feedback and fan cables
864
Pre-assembled Cables / Servo motor, feedback and fan cables
Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.
865
Pre-assembled Cables / Servo motor, feedback and fan cables
866
Pre-assembled Cables / Servo motor, feedback and fan cables
Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.
867
Pre-assembled Cables / Servo motor, feedback and fan cables
Note
Please observe the installation instructions
for laying cables in cable carriers and
the drive or controller manufacturer's
information about maximum permitted
cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.
868
Pre-assembled Cables / Servo motor, feedback and fan cables
Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.
869
Pre-assembled Cables / Servo motor, feedback and fan cables
870
Pre-assembled Cables / Servo motor, feedback and fan cables
Note
Please observe the drive or controller
manufacturer's information about
maximum permitted cable length.
The prefabricated cables listed here are not
original parts, but accessories manufactured
by the company HELUKABEL GmbH.
The data, standards and approvals relate
solely to the bulk goods used.
871
Pre-assembled Cables / Servo motor, feedback and fan cables
872
Pre-assembled Cables / Servo motor, feedback and fan cables
873
Pre-assembled Cables / Servo motor, feedback and fan cables
874
Pre-assembled Cables / Servo motor, feedback and fan cables
Helukabel Helukabel
Designation Part no.
spiral cable 312879 PUR sw 660893
875
Pre-assembled Cables / Servo motor, feedback and fan cables
Helukabel Helukabel
Designation Part no.
adapter cables 296466 PVC sw 660894
876
877
ROBOFLEX RECYCLE
ROBOFLEX -recycle
M12 female one-end pre-assembled 3-pin, 4-pin, and 5-pin 880
ROBOFLEX -recycle
M12 both ends pre-assembled 883
ROBOFLEX -recycle
M12 plug straight or angled one end preassembled 3-pin, 4-pin, and 5-pin 886
ROBOFLEX -recycle
M8 both ends pre-assembled 888
ROBOFLEX -recycle
M8 plug straight or angled one end preassembled 3-pin and 4-pin 890
ROBOFLEX -recycle
M12 sensor cable screened both ends pre-assembled 893
ROBOFLEX -recycle
Twin cables M12 to M12 896
879
Pre-assembled Cables / ROBOFLEX-recycle
Continuation
880
Pre-assembled Cables / ROBOFLEX-recycle
881
Pre-assembled Cables / ROBOFLEX-recycle
882
Pre-assembled Cables / ROBOFLEX-recycle
Continuation
883
Pre-assembled Cables / ROBOFLEX-recycle
884
Pre-assembled Cables / ROBOFLEX-recycle
885
Pre-assembled Cables / ROBOFLEX-recycle
886
Pre-assembled Cables / ROBOFLEX-recycle
plug straight
Part no. Cable type / Length Plug type Cop.
cross-sec. m weight
mm kg / 1000 pcs.
670668 ROBOFLEX-recycle 3 x 0,34 1,5 socket straight 14,7 -
670669 ROBOFLEX-recycle 3 x 0,34 3,0 socket straight 29,4 -
670670 ROBOFLEX-recycle 3 x 0,34 5,0 socket straight 49,0 -
670671 ROBOFLEX-recycle 3 x 0,34 10,0 socket straight 98,0 -
670656 ROBOFLEX-recycle 3 x 0,34 1,5 socket angled 14,7 -
670657 ROBOFLEX-recycle 3 x 0,34 3,0 socket angled 29,4 -
670658 ROBOFLEX-recycle 3 x 0,34 5,0 socket angled 49,0 -
670659 ROBOFLEX-recycle 3 x 0,34 10,0 socket angled 98,0 -
670684 ROBOFLEX-recycle 4 x 0,34 1,5 socket straight 19,7 -
670685 ROBOFLEX-recycle 4 x 0,34 3,0 socket straight 39,3 -
670686 ROBOFLEX-recycle 4 x 0,34 5,0 socket straight 65,5 -
670687 ROBOFLEX-recycle 4 x 0,34 10,0 socket straight 131,0 -
670693 ROBOFLEX-recycle 4 x 0,34 1,5 socket angled 19,7 -
670694 ROBOFLEX-recycle 4 x 0,34 3,0 socket angled 39,3 -
670695 ROBOFLEX-recycle 4 x 0,34 5,0 socket angled 65,5 -
670696 ROBOFLEX-recycle 4 x 0,34 10,0 socket angled 131,0 -
887
Pre-assembled Cables / ROBOFLEX-recycle
Continuation
888
Pre-assembled Cables / ROBOFLEX-recycle
889
Pre-assembled Cables / ROBOFLEX-recycle
890
Pre-assembled Cables / ROBOFLEX-recycle
Continuation
891
Pre-assembled Cables / ROBOFLEX-recycle
892
Pre-assembled Cables / ROBOFLEX-recycle
893
Pre-assembled Cables / ROBOFLEX-recycle
894
Pre-assembled Cables / ROBOFLEX-recycle
895
Pre-assembled Cables / ROBOFLEX-recycle
896
897
CONNECTING CABLES & EXTENSIONS
Extensions/supply cables CEE extensions, cold equipment cables, PVC extensions 904
899
Pre-assembled Cables / Connecting and Extension Cables
Application
H03VV-F
This cable is highly suitable as a hand tool connection for lightweight applications. It is often
used as a connecting cable for household appliances.
H05VV-F
This cable is highly suitable as a hand tool connection for medium-weight applications. It can
also be used in wet rooms. As a connecting cable: for machine installation.
900
Pre-assembled Cables / Connecting and Extension Cables
Application
H05RR-F
Lightweight rubber-sheathed cable for use as a hand tool connection and lightweight workshop tools for light to medium-weight applications in dry
and wet rooms.
H05RN-F
Medium-weight rubber-sheathed cable for use as a hand tool connection and lightweight workshop equipment for light to medium-weight applications
in dry rooms, wet rooms outdoors and in industrial water.
H07RN-F
Heavyweight rubber-sheathed cable for use on heavy equipment and tools (agricultural, construction industry). For heavyweight applications in dry
rooms, wet rooms, outdoors and in
industrial water.
U
87084 H07RN-F 3 G 1,5 5,0 PROTECTED PLUG, straight 216,0 16
84499 H07RN-F 3 G 1,5 10,0 PROTECTED PLUG, straight 432,0 16
84653 H07RN-F 3 G 1,5 3,0 PROTECTED PLUG, angled 129,6 16
84654 H07RN-F 3 G 1,5 5,0 PROTECTED PLUG, angled 216,0 16
84655 H07RN-F 3 G 1,5 10,0 PROTECTED PLUG, angled 432,0 16
901
Pre-assembled Cables / Connecting and Extension Cables
Application
These robust rubber sheathed cables can be used where high demands are placed flexibility and mechanical stress. For application in dry, moist and
wet rooms and in open air, in steel works and rolling mills in heating and air-conditioning systems, in the bottling industry, in machinery and plant
construction, in the chemical industry as well as for the professional and the hobby enthusiast. The choice of yellow as the sheath colour ensures
additional safety. Can be used in potentially explosive areas acc. to DIN VDE 0165.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
902
Pre-assembled Cables / Connecting and Extension Cables
Application
These cables can be used for medium mechanical loads in dry, damp or wet environments, e. g. for connecting agricultural and commercial equipment
and heaters provided there is no danger of contact with the hot parts or by radiation of heat. These robust and flexible cables are used for electrical
tools such as drills and hand-held circular saws, as well as for portable motors and machinery in agriculture, at building sites, docks and refrigeration
plants.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
903
Pre-assembled Cables / Connecting and Extension Cables
CEE-Extensions
Part no. Cable type / Length Cable colour Plug 1 Plug 2 AWG-No.
cross-sec. m
mm
84688 H07RN-F 5 G 1,5 5,0 black CEE connector 16A CEE coupling 16A 16
84689 H07RN-F 5 G 1,5 10,0 black CEE connector 16A CEE coupling 16A 16
87164 H07RN-F 5 G 1,5 25,0 black CEE connector 16A CEE coupling 16A 16
84690 H07RN-F 5 G 2,5 5,0 black CEE connector 32A CEE coupling 32A 14
84691 H07RN-F 5 G 2,5 10,0 black CEE connector 32A CEE coupling 32A 14
87416 H07RN-F 5 G 2,5 25,0 black CEE connector 32A CEE coupling 32A 14
Part no. Cable type / Length Cable colour Plug 1 Plug 2 AWG-No.
cross-sec. m
mm
87476 H05VV-F 3 G 0,75 2,0 black PROTECTED PLUG, angled Cold device socket 19
86762 H05VV-F 3 G 0,75 2,0 grey PROTECTED PLUG, angled Cold device socket 19
84674 H05VV-F 3 G 0,75 3,0 black PROTECTED PLUG, angled Cold device socket 19
87845 H05VV-F 3 G 0,75 3,0 grey PROTECTED PLUG, angled Cold device socket 19
84675 H05VV-F 3 G 1,0 2,0 grey PROTECTED PLUG, angled Cold device socket 17
87196 H05VV-F 3 G 1,0 2,0 black PROTECTED PLUG, angled Cold device socket 17
84676 H05VV-F 3 G 1,0 3,0 grey PROTECTED PLUG, angled Cold device socket 17
87549 H05VV-F 3 G 1,0 3,0 black PROTECTED PLUG, angled Cold device socket 17
Part no. Cable type / Length Cable colour Plug 1 Plug 2 AWG-No.
cross-sec. m
mm
87445 H05VV-F 3 G 1,5 2,0 white PROTECTED PLUG, straight PROTECTED PLUG coupling 16
87919 H05VV-F 3 G 1,5 3,0 white PROTECTED PLUG, straight PROTECTED PLUG coupling 16
84178 H05VV-F 3 G 1,5 5,0 white PROTECTED PLUG, straight PROTECTED PLUG coupling 16
904
Pre-assembled Cables / Connecting and Extension Cables
Application
These pre-assembled cables with pre-wired front connectors are highly suitable for Simatic S7 programmable logic controllers (PLC).
As opposed to past days when you had to cut to length, strip, crimp, screw in and mark, pre-wired front connectors offer the customer a host of
advantages for the Simatic S7 system.
905
906
SPIRAL CABLES
Designation Page
907
Spiral Cables
Application
Lighting industry
Data installations
Shops
Telecommunication
908
Spiral Cables
Application
Machine Construction
Electrical Tools
Building Industry
Handling Equipment
Entertainment Equipment
Medical devices
Measurement instruments
Rolling doors
Continuation
V
909
Spiral Cables
910
Spiral Cables
Application
Machine Construction
Electrical Tools
Building Industry
Handling Equipment
Entertainment Equipment
Medical devices
Measurement instruments
Rolling doors
Continuation
911
Spiral Cables
912
Spiral Cables
Application
Handling Equipment
Entertainment Equipment
Medical devices
Measurement instruments
Rolling doors
In all fields in which
low-current cables are used
Continuation
913
Spiral Cables
914
Spiral Cables
Application
Handling Equipment
Entertainment Equipment
Medical devices
Measurement instruments
Rolling doors
In all fields in which
low-current cables are used
Continuation
915
Spiral Cables
916
SHIPWIRING & MARINE CABLES
Ships Telephone Cables FMGCH 250 V (FMGCG*) halogen-free in accordance with DIN 89 159/98 924
Ships Power Cables MPRXCX 0.6/1 kV in accordance with IEC 60092-353, halogen-free, screened 932
SHIPFLEX 512 Drag chain cable, halogen-free, EMC-preferred type, meter marking 933
SHIPFLEX 330
Drag chain cable, halogen-free, EMC-preferred type, meter marking 934
SHIPFLEX 340 Drag chain cable, halogen-free, EMC-preferred type, meter marking 935
SHIPFLEX 109
Cable drag chain, single core, halogen-free. EMC-preferred type (-C-type) meter marked 936
SHIPFLEX 109
Drag chain cable, halogen-free, EMC-preferred type, meter marking 937
SHIPFLEX 113 Drag chain cable, halogen-free, EMC-preferred type, meter marking 938
SHIPFLEX 121
Drag chain cable, halogen-free, EMC-preferred type, meter marking 939
919
SELECTION TABLE - DRAG CHAIN CABLES
ng
in
xi
g
/s 2
ce
fle
in
/
an
ex
ge U
(m
-
es ist
lta 0 /
- fl
us
)
-c t d
vo U
/s
di
io
)
C)
g ge
en
(m
ra
at
or
(
tin lta
er
m
re
in
s
25
e
el
nt
ra vo
ee
le
ui CSA
ov
nd
tu
s
c
yc
)
al
to
le
sp
ac
pe l
ra
ia
m
O ina
be
ov
r
.c
up
va
te
eq L/
er
pe
.
ge
.
ax
ax
ou
pr
ax
ax
m
om
.
at
in
U
m
=
Ap
M
M
0
Pa
M
M
M
M
(D
(1
Te
N
Drag chain cables for ship & offshore applications
SHIPFLEX 512 100 7.5 x D 4 10 11 Mio TPE/CU/PUR 1000V -40 to +80 UL/CSA 933 -
SHIPFLEX 330
100 7.5 x D 4 10 11 Mio TPE/CU/PUR 300V -40 to +80 UL/CSA 934 -
SHIPFLEX 340 100 7.5 x D 4 10 11 Mio TPE/CU/PUR 300V -40 to +80 UL/CSA 935 -
SHIPFLEX 109 100 7.5 x D 4 10 11 Mio TPE/CU/PUR 1000V -40 to +80 UL/CSA 936 -
SHIPFLEX 109
100 7.5 x D 4 10 11 Mio TPE/CU/PUR 1000V -40 to +80 UL/CSA 937 -
SHIPFLEX 113 100 7.5 x D 4 10 11 Mio TPE/CU/PUR 1000V -40 to +80 UL/CSA 938 -
SHIPFLEX 121 100 7.5 x D 4 10 11 Mio TPE/CU/PUR 1000V -40 to +80 UL/CSA 939 -
A cycle is a double lift: a representative sample has been tested and measurot in our Test Workshop. The cycle count is only valid when appropriatel
and professionally installed (see the installation manual: cable installation in drag chains, see pages 1036 and 1037).
920
Shipwiring and Marine Cables
Application
For measurement, control, regulation, control and alarm systems; radio, positioning and messaging systems. For fixed installation on ships in rooms
and on open decks.
Part no. No.pairs x Outer Cop. Weight AWG-No. Part no. No.pairs x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
59138 1 x 2 x 0,75 8,5 62,0 90,0 18 59142 10 x 2 x 0,75 18,5 319,0 470,0 18
59139 2 x 2 x 0,75 9,0 87,0 130,0 18 59143 14 x 2 x 0,75 21,0 445,0 610,0 18
59140 4 x 2 x 0,75 13,0 153,0 230,0 18 59144 19 x 2 x 0,75 24,0 525,0 770,0 18
59141 7 x 2 x 0,75 15,5 230,0 340,0 18 59145 24 x 2 x 0,75 27,0 663,0 950,0 18
924
Shipwiring and Marine Cables
Application
A connection and a connection cable for measuring and control devices for communication systems, production lines, conveyor systems for fixed and
variable connection in humid, wet and dry areas.
These PVC single cores are also suitable for use in ship building.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
59450 1x6 8,3 57,4 148,0 10 59454 1 x 35 15,2 335,0 565,0 2
59451 1 x 10 10,3 95,8 221,0 8 59455 1 x 50 18,1 479,5 788,0 1
59452 1 x 16 10,3 153,4 293,0 6 59456 1 x 70 21,1 671,0 1061,0 2/0
59453 1 x 25 13,7 239,5 447,0 4 59457 1 x 95 22,8 910,0 1355,0 3/0
929
Shipwiring and Marine Cables
Application
Ideally suitedn for for fixed installation but also for the variable use of manufacturing lines, machine tools, conveyor systems and robotic assembly
lines. A line that can also be used in shipbuilding.The galvanized steel braid protects against mechanical stress and simultaneously effective against
electrical interference.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. mm weight approx. cross-sec. approx. mm weight approx.
mm kg / km kg / km mm kg / km kg / km
59460 2 x 1,5 9,7 28,7 146,0 16 59466 4 x 2,5 13,3 95,8 298,0 14
59461 3 x 1,5 10,1 43,1 166,0 16 59467 5 x 2,5 14,3 120,0 355,0 14
59462 4 x 1,5 10,8 57,5 198,0 16 59468 4x4 16,2 153,5 358,0 12
59463 5 x 1,5 11,6 71,9 230,0 16 59469 5x4 17,5 193,0 535,0 12
59464 7 x 1,5 13,3 100,6 299,0 16 59470 4x6 18,4 230,3 595,0 10
59465 3 x 2,5 11,6 72,1 231,0 14 59471 5x6 19,7 288,0 714,0 10
930
Shipwiring and Marine Cables
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
Application
For fixed installation on ships and offshore-units in all locations below the upper metallic deck.
Particularly suitable for installation on passenger ships.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
59654 1x4 5,5 - 8,0 38,0 70,0 12 59681 3 x 25 19,0 - 21,5 720,0 970,0 4
59655 1x6 6,0 - 8,5 58,0 95,0 10 59682 3 x 35 20,5 - 23,5 1008,0 1290,0 2
59656 1 x 10 7,0 - 9,5 96,0 140,0 8 59683 3 x 50 24,0 - 27,0 1440,0 1720,0 1
59657 1 x 16 8,0 - 10,5 154,0 200,0 6 59684 3 x 70 26,5 - 29,5 2016,0 2450,0 2/0
59658 1 x 25 9,5 - 12,0 240,0 320,0 4 59685 3 x 95 30,5 - 34,0 2736,0 3305,0 3/0
59659 1 x 35 10,5 - 13,0 336,0 420,0 2 59686 3 x 120 33,5 - 37,5 3456,0 4140,0 4/0
59660 1 x 50 12,0 - 14,5 480,0 560,0 1 59687 4 x 1,5 8,5 - 11,0 58,0 130,0 16
59661 1 x 70 14,0 - 16,5 672,0 780,0 2/0 59688 4 x 2,5 10,0 - 12,5 96,0 180,0 14
59662 1 x 95 16,0 - 19,0 912,0 1030,0 3/0 59689 4x4 11,0 - 13,5 154,0 245,0 12
59663 1 x 120 18,0 - 21,0 1152,0 1290,0 4/0 59690 4x6 12,0 - 14,5 230,0 345,0 10
59664 1 x 150 20,0 - 23,5 1440,0 1590,0 300 kcmil 59691 4 x 10 14,5 - 17,0 384,0 535,0 8
59665 1 x 185 22,0 - 25,5 1776,0 1960,0 350 kcmil 59692 4 x 16 17,0 - 19,5 614,0 795,0 6
59666 1 x 240 25,0 - 28,5 2304,0 2560,0 500 kcmil 59693 4 x 25 21,0 - 24,0 960,0 1300,0 4
59667 1 x 300 27,5 - 31,5 2880,0 3200,0 600 kcmil 59694 4 x 35 23,0 - 26,0 1344,0 1725,0 2
59668 2 x 1,5 7,0 - 9,5 29,0 80,0 16 59695 4 x 50 27,0 - 30,0 1920,0 2310,0 1
59669 2 x 2,5 8,0 - 10,5 48,0 105,0 14 59696 4 x 70 31,0 - 34,5 2688,0 3275,0 2/0
59670 2x4 9,0 - 11,5 77,0 145,0 12 59697 4 x 95 35,5 - 39,5 3648,0 4445,0 3/0
59671 2x6 10,0 - 12,5 115,0 190,0 10 59698 5 x 1,5 9,5 - 12,0 72,0 165,0 16
59672 2 x 10 12,5 - 15,0 192,0 290,0 8 59699 5 x 2,5 10,5 - 13,0 120,0 225,0 14
59673 2 x 16 14,5 - 17,0 307,0 430,0 6 59700 7 x 1,5 10,5 - 13,0 101,0 205,0 16
59674 2 x 25 18,0 - 20,5 480,0 680,0 4 59701 10 x 1,5 13,5 - 16,0 144,0 290,0 16
59675 3 x 1,5 8,0 - 10,5 43,0 100,0 16 59702 12 x 1,5 14,0 - 17,0 173,0 330,0 16
59676 3 x 2,5 9,0 - 11,5 72,0 140,0 14 59703 14 x 1,5 14,5 - 17,5 202,0 375,0 16
59677 3x4 10,0 - 12,5 115,0 190,0 12 59704 16 x 1,5 15,5 - 18,5 230,0 440,0 16
59678 3x6 11,0 - 13,5 173,0 260,0 10 59705 19 x 1,5 16,5 - 19,5 274,0 500,0 16
59679 3 x 10 13,0 - 15,5 288,0 410,0 8 59706 24 x 1,5 19,5 - 22,5 346,0 630,0 16
59680 3 x 16 15,5 - 18,0 461,0 600,0 6
931
Shipwiring and Marine Cables
Note
AWG sizes are approximate equivalent
values. The actual cross-section is in mm.
3-core cables with green-yellow marked
core and/or as MPRXCX 331 (insulation
integrity to IEC 60331) also available.
Application
For fixed installation on ships and offshore-units in all locations below the upper metallic deck. Particularly suitable for installation on passenger ships.
The good screening qualities of the copper braid also reduce radio interferences and electrical influences to electronic installations.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. min. - max. weight approx. cross-sec. min. - max. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
59707 1x4 6,9 - 8,4 81,0 105,0 12 59734 3 x 25 21,2 - 23,2 924,0 950,0 4
59708 1x6 7,5 - 9,5 104,0 130,0 10 59735 3 x 35 20,8 - 23,8 1233,0 1470,0 2
59709 1 x 10 8,7 - 10,7 149,0 180,0 8 59736 3 x 50 24,3 - 26,8 1703,0 1870,0 1
59710 1 x 16 9,5 - 11,5 214,0 250,0 6 59737 3 x 70 27,6 - 30,1 2413,0 2650,0 2/0
59711 1 x 25 11,7 - 13,4 311,0 380,0 4 59738 3 x 95 31,8 - 34,3 3192,0 3500,0 3/0
59712 1 x 35 12,6 - 15,1 416,0 480,0 2 59739 3 x 120 34,3 - 36,8 3975,0 4300,0 4/0
59713 1 x 50 14,6 - 17,1 572,0 660,0 1 59740 4 x 1,5 10,1 - 11,6 147,0 200,0 16
59714 1 x 70 16,9 - 19,4 779,0 900,0 2/0 59741 4 x 2,5 11,2 - 12,7 190,0 240,0 14
59715 1 x 95 18,6 - 21,1 1034,0 1170,0 3/0 59742 4x4 12,3 - 13,8 284,0 350,0 12
59716 1 x 120 19,7 - 22,2 1316,0 1410,0 4/0 59743 4x6 14,0 - 16,0 371,0 450,0 10
59717 1 x 150 22,6 - 25,1 1615,0 1750,0 300 kcmil 59744 4 x 10 17,2 - 19,2 545,0 670,0 8
59718 1 x 185 24,7 - 27,2 1968,0 2160,0 350 kcmil 59745 4 x 16 19,4 - 21,4 796,0 950,0 6
59719 1 x 240 27,9 - 30,4 2506,0 2770,0 500 kcmil 59746 4 x 25 23,8 - 25,8 1170,0 1470,0 4
59720 1 x 300 30,2 - 32,7 3345,0 3440,0 600 kcmil 59747 4 x 35 23,0 - 25,5 1578,0 1930,0 2
59721 2 x 1,5 8,3 - 9,8 105,0 130,0 16 59748 4 x 50 26,0 - 28,5 2278,0 2500,0 1
59722 2 x 2,5 9,1 - 10,6 132,0 160,0 14 59749 4 x 70 31,5 - 34,0 3090,0 3550,0 2/0
59723 2x4 10,3 - 11,8 170,0 205,0 12 59750 4 x 95 35,5 - 38,0 4110,0 4600,0 3/0
59724 2x6 12,1 - 14,1 217,0 290,0 10 59751 5 x 1,5 10,9 - 12,4 171,0 225,0 16
59725 2 x 10 14,9 - 16,9 400,0 307,0 8 59752 5 x 2,5 12,1 - 13,6 220,0 330,0 14
59726 2 x 16 16,7 - 18,7 471,0 560,0 6 59753 7 x 1,5 11,7 - 13,2 209,0 310,0 16
59727 2 x 25 20,3 - 22,3 670,0 840,0 4 59754 10 x 1,5 14,5 - 16,0 318,0 400,0 16
59728 3 x 1,5 8,8 - 10,3 125,0 160,0 16 59755 12 x 1,5 15,3 - 16,8 353,0 440,0 16
59729 3 x 2,5 10,1 - 11,6 161,0 200,0 14 59756 14 x 1,5 16,5 - 18,0 394,0 500,0 16
59730 3x4 11,1 - 12,6 215,0 250,0 12 59757 16 x 1,5 17,7 - 19,2 432,0 550,0 16
59731 3x6 12,1 - 14,1 282,0 360,0 10 59758 19 x 1,5 18,3 - 19,8 486,0 620,0 16
59732 3 x 10 14,8 - 16,8 417,0 520,0 8 59759 24 x 1,5 20,0 - 21,5 601,0 770,0 16
59733 3 x 16 17,6 - 19,6 636,0 750,0 6
932
Shipwiring and Marine Cables / Lloyds Register
Application
HELUKABEL SHIPFLEX 512 is a new developed and successfully tested screened special drag chain cable which meets the requirements of the strict
standards for application in offshore-areas. For this two - line standard there is a Lloyds Register approval . The outer sheath insulation of
non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions. For applications which go beyond standard
solutions we recommend that you fill out our especially developed questionnaire for drag chains. Before installation in cable drag chains please read
the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
19864 2 x 0,5 20 6,3 35,0 50,0 19896 12 G 1,5 16 13,8 267,0 363,0
19865 3 G 0,5 20 6,5 42,0 60,0 19897 18 G 1,5 16 16,2 374,0 496,0
19866 4 G 0,5 20 7,0 47,0 64,0 19898 25 G 1,5 16 19,0 526,0 724,0
19867 5 G 0,5 20 7,5 56,0 79,0 19899 36 G 1,5 16 21,5 702,0 1190,0
19868 7 G 0,5 20 8,5 69,0 101,0 19900 2 x 2,5 14 9,5 96,0 136,0
19869 12 G 0,5 20 10,0 108,0 164,0 19901 3 G 2,5 14 10,3 144,0 179,0
19870 18 G 0,5 20 11,5 145,0 227,0 19902 4 G 2,5 14 11,3 149,0 201,0
19871 25 G 0,5 20 13,5 240,0 331,0 19903 5 G 2,5 14 12,4 181,0 232,0
19872 36 G 0,5 20 15,2 318,0 457,0 19904 7 G 2,5 14 14,4 255,0 357,0
19873 2 x 0,75 19 7,0 40,0 65,0 19905 12 G 2,5 14 17,5 441,0 586,0
19874 3 G 0,75 19 7,2 52,0 71,0 19906 18 G 2,5 14 20,3 604,0 1064,0
19875 4 G 0,75 19 7,8 60,0 82,0 19907 25 G 2,5 14 24,2 793,0 1411,0
19876 5 G 0,75 19 8,5 71,0 97,0 19908 36 G 2,5 14 27,2 1034,0 1623,0
19877 7 G 0,75 19 9,6 91,0 141,0 19909 3G4 12 11,5 174,0 257,0
19878 12 G 0,75 19 11,5 142,0 217,0 19910 4G4 12 12,4 230,0 324,0
19879 18 G 0,75 19 13,0 212,0 304,0 19911 5G4 12 13,5 274,0 401,0
19880 25 G 0,75 19 15,8 281,0 420,0 19912 6G4 12 15,2 295,0 456,0
19881 36 G 0,75 19 17,5 350,0 535,0 19913 7G4 12 16,3 316,0 511,0
19882 2x1 18 7,4 50,0 69,0 19914 3G6 10 13,5 240,0 343,0
19883 3G1 18 7,7 60,0 84,0 19915 4G6 10 15,2 305,0 427,0
19884 4G1 18 8,5 71,0 104,0 19916 5G6 10 16,5 442,0 562,0
19885 5G1 18 9,0 88,0 130,0 19917 6G6 10 17,8 471,0 628,0
19886 7G1 18 10,4 111,0 160,0 19918 7G6 10 19,5 505,0 692,0
19887 12 G 1 18 12,4 184,0 270,0 19919 3 G 10 8 17,1 367,0 731,0
19888 18 G 1 18 14,3 260,0 391,0 19920 4 G 10 8 19,0 549,0 992,0
19889 25 G 1 18 17,0 349,0 547,0 19921 5 G 10 8 20,7 607,0 1014,0
19890 36 G 1 18 19,0 510,0 790,0 19922 6 G 10 8 22,0 711,0 1241,0
19891 2 x 1,5 16 8,0 63,0 90,0 19923 7 G 10 8 24,0 820,0 1491,0
19892 3 G 1,5 16 8,3 80,0 109,0 19924 3 G 16 6 19,8 692,0 1004,0
19893 4 G 1,5 16 9,2 97,0 132,0 19925 4 G 16 6 21,8 840,0 1296,0
19894 5 G 1,5 16 10,0 119,0 169,0 19926 5 G 16 6 24,0 1050,0 1658,0
19895 7 G 1,5 16 11,6 147,0 219,0
933
Shipwiring and Marine Cables / Lloyds Register
Application
HELUKABEL SHIPFLEX 330 is a new developed and successfully tested special drag chain cable with overall screening which meets the requirements
of the strict standards for application in offshore-areas. For this two-line standard there is a Lloyds Register approval. The outer sheath insulation
of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions. For applications which go beyond standard
solutions we recommend that you fill out our especially developed questionnaire for drag chains. Before installation in cable drag chains please read
the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
19846 2 x 0,25 24 5,0 14,9 38,0 19855 2 x 0,34 22 5,2 18,1 45,0
19847 3 x 0,25 24 5,2 18,8 44,0 19856 3 x 0,34 22 5,5 28,7 60,0
19848 4 x 0,25 24 5,5 21,3 51,0 19857 4 x 0,34 22 5,8 35,7 76,0
19849 5 x 0,25 24 5,8 31,0 68,0 19858 5 x 0,34 22 6,5 39,1 82,0
19850 7 x 0,25 24 6,7 39,6 82,0 19859 7 x 0,34 22 7,2 52,7 110,0
19851 12 x 0,25 24 8,0 59,1 124,0 19860 12 x 0,34 22 8,5 76,4 166,0
19852 18 x 0,25 24 9,0 78,4 150,0 19861 18 x 0,34 22 10,0 99,7 216,0
19853 25 x 0,25 24 10,8 101,0 204,0 19862 25 x 0,34 22 12,0 155,0 305,0
19854 36 x 0,25 24 11,5 126,4 230,0 19863 36 x 0,34 22 13,0 188,0 340,0
934
Shipwiring and Marine Cables / Lloyds Register
Application
HELUKABEL SHIPFLEX 340 is a new developed and successfully tested special drag chain cable with overall screening which meets the requirements
of the strict standards for application in offshore-areas. For this two - line standard there is a Lloyds Register approval. The outer sheath insulation
of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions. For applications which go beyond standard
solutions we recommend that you fill out our especially developed questionnaire for drag chains. Before installation in cable drag chains please read
the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.pairs x AWG-No. Outer Cop. Weight Part no. No.pairs x AWG-No. Outer Cop. Weight
no.cores x approx. mm weight approx. no.cores x approx. mm weight approx.
cross-sec. kg / km kg / km cross-sec. kg / km kg / km
mm mm
19927 2 x 2 x 0,25 24 6,8 32,0 60,0 19948 5 x 2 x 0,5 20 9,7 86,0 160,0
19928 3 x 2 x 0,25 24 7,1 38,0 70,0 19949 6 x 2 x 0,5 20 10,6 103,0 170,0
19929 4 x 2 x 0,25 24 7,5 43,0 82,0 19950 7 x 2 x 0,5 20 11,5 117,0 191,0
19930 5 x 2 x 0,25 24 8,0 51,0 99,0 19951 12 x 2 x 0,5 20 13,5 199,0 361,0
19931 6 x 2 x 0,25 24 8,5 72,0 126,0 19952 18 x 2 x 0,5 20 15,7 265,0 427,0
19932 7 x 2 x 0,25 24 9,2 75,0 135,0 19953 25 x 2 x 0,5 20 18,2 344,0 740,0
19933 12 x 2 x 0,25 24 11,4 117,0 189,0 19954 2 x 2 x 0,75 19 9,0 61,0 102,0
19934 18 x 2 x 0,25 24 13,5 148,0 248,0 19955 3 x 2 x 0,75 19 9,5 87,0 144,0
19935 25 x 2 x 0,25 24 15,0 233,0 343,0 19956 4 x 2 x 0,75 19 10,3 95,0 160,0
19936 2 x 2 x 0,34 22 7,4 41,0 81,0 19957 5 x 2 x 0,75 19 11,2 115,0 193,0
19937 3 x 2 x 0,34 22 7,7 52,0 100,0 19958 6 x 2 x 0,75 19 12,1 137,0 218,0
19938 4 x 2 x 0,34 22 8,4 59,0 119,0 19959 7 x 2 x 0,75 19 13,0 153,0 298,0
19939 5 x 2 x 0,34 22 9,1 67,0 135,0 19960 12 x 2 x 0,75 19 16,0 261,0 406,0
19940 6 x 2 x 0,34 22 10,0 86,0 163,0 19961 18 x 2 x 0,75 19 18,0 374,0 519,0
19941 7 x 2 x 0,34 22 10,5 94,0 170,0 19962 2x2x1 18 10,0 73,0 120,0
19942 12 x 2 x 0,34 22 12,2 122,0 220,0 19963 3x2x1 18 10,4 94,0 161,0
19943 18 x 2 x 0,34 22 14,4 197,0 277,0 19964 4x2x1 18 11,8 118,0 184,0
19944 25 x 2 x 0,34 22 16,5 238,0 400,0 19965 5x2x1 18 12,6 139,0 217,0
19945 2 x 2 x 0,5 20 8,0 53,0 100,0 19966 6x2x1 18 13,6 188,0 295,0
19946 3 x 2 x 0,5 20 8,4 73,0 131,0 19967 7x2x1 18 14,8 204,0 311,0
19947 4 x 2 x 0,5 20 9,0 77,0 149,0 19968 12 x 2 x 1 18 18,0 324,0 602,0
935
Shipwiring and Marine Cables / Lloyds Register
Application
HELUKABEL SHIPFLEX 109 Single is a new developed and successfully tested special drag chain cable which meets the requirements of the strict
standards for application in offshore-areas. For this two - line standard there is a Lloyds Register approval . The outer sheath insulation of
non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions. For applications which go beyond standard
solutions we recommend that you fill out our especially developed questionnaire for drag chains. Before installation in cable drag chains please read
the installation instructions.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
SHIPFLEX 109 unscreened SHIPFLEX 109 screened
Part no. No.cores x AWG-No. Core Outer Cop. Weight Part no. No.cores x AWG-No. Core Outer Cop. Weight
cross-sec. colour approx. weight approx. cross-sec. colour approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
21388 1x6 10 black 6,9 58,0 108,0 19798 1x6 10 black 7,6 72,0 140,0
21374 1G6 10 Green-yellow 6,9 58,0 108,0 21330 1G6 10 Green-yellow 7,6 72,0 140,0
21389 1 x 10 8 black 8,3 96,0 170,0 19799 1 x 10 8 black 9,1 130,0 225,0
21375 1 G 10 8 Green-yellow 8,3 96,0 170,0 21331 1 G 10 8 Green-yellow 9,1 130,0 225,0
21390 1 x 16 6 black 9,5 154,0 240,0 19800 1 x 16 6 black 10,2 190,0 295,0
21376 1 G 16 6 Green-yellow 9,5 154,0 240,0 21332 1 G 16 6 Green-yellow 10,2 190,0 295,0
21391 1 x 25 4 black 11,3 240,0 370,0 19801 1 x 25 4 black 12,1 260,0 415,0
21377 1 G 25 4 Green-yellow 11,3 240,0 370,0 21333 1 G 25 4 Green-yellow 12,1 260,0 415,0
21392 1 x 35 2 black 12,7 336,0 490,0 19802 1 x 35 2 black 13,5 405,0 610,0
21378 1 G 35 2 Green-yellow 12,7 336,0 490,0 21334 1 G 35 2 Green-yellow 13,5 405,0 610,0
21393 1 x 50 1 black 15,0 480,0 665,0 19803 1 x 50 1 black 15,9 560,0 817,0
21379 1 G 50 1 Green-yellow 15,0 480,0 665,0 21335 1 G 50 1 Green-yellow 15,9 560,0 817,0
21394 1 x 70 2/0 black 16,3 672,0 910,0 19804 1 x 70 2/0 black 17,3 780,0 1065,0
21380 1 G 70 2/0 Green-yellow 16,3 672,0 910,0 21336 1 G 70 2/0 Green-yellow 17,3 780,0 1065,0
21395 1 x 95 3/0 black 18,8 912,0 1190,0 19805 1 x 95 3/0 black 19,5 1030,0 1340,0
21381 1 G 95 3/0 Green-yellow 18,8 912,0 1190,0 21337 1 G 95 3/0 Green-yellow 19,5 1030,0 1340,0
21396 1 x 120 4/0 black 20,9 1152,0 1530,0 19806 1 x 120 4/0 black 21,8 1285,0 1735,0
21382 1 G 120 4/0 Green-yellow 20,9 1152,0 1530,0 21338 1 G 120 4/0 Green-yellow 21,8 1285,0 1735,0
21397 1 x 150 300 kcmil black 23,2 1440,0 1720,0 19807 1 x 150 300 kcmil black 24,1 1430,0 1910,0
21383 1 G 150 300 kcmil Green-yellow 23,2 1440,0 1720,0 21339 1 G 150 300 kcmil Green-yellow 24,1 1430,0 1910,0
21398 1 x 185 350 kcmil black 25,7 1776,0 2280,0 19808 1 x 185 350 kcmil black 26,5 1940,0 2610,0
21384 1 G 185 350 kcmil Green-yellow 25,7 1776,0 2280,0 21406 1 G 185 350 kcmil Green-yellow 26,5 1940,0 2610,0
21399 1 x 240 500 kcmil black 28,2 2304,0 2895,0 19809 1 x 240 500 kcmil black 29,2 2530,0 3274,0
21404 1 G 240 500 kcmil Green-yellow 28,2 2304,0 2895,0 21410 1 G 240 500 kcmil Green-yellow 29,2 2530,0 3274,0
936
Shipwiring and Marine Cables / Lloyds Register
Application
HELUKABEL SHIPFLEX 109 is a new developed and successfully tested special drag chain cable with overall screening which meets the requirements
of the strict standards for application in offshore-areas. For this two-line standard there is a Lloyds Register approval. The outer sheath insulation
of non-adhesive Polyurethan allows the application in extremely oily and rough environmental conditions. For applications which go beyond standard
solutions we recommend that you fill out our especially developed questionnaire for drag chains. Before installation in cable drag chains please read
the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x AWG-No. Outer Cop. Weight Part no. No.cores x AWG-No. Outer Cop. Weight
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
19810 4G1 18 9,0 84,0 124,0 19817 4 G 25 4 27,6 1180,0 1660,0
19811 4 G 1,5 16 10,5 105,0 175,0 19818 4 G 35 2 32,7 1600,0 2400,0
19812 4 G 2,5 14 11,7 157,0 265,0 19819 4 G 50 1 37,0 2165,0 2600,0
19813 4G4 12 13,4 231,0 390,0 19820 4 G 70 2/0 43,0 3196,0 4600,0
19814 4G6 10 15,6 332,0 570,0 19969 3 G 95 3/0 41,0 3090,0 4480,0
19815 4 G 10 8 19,2 527,0 804,0 19821 4 G 95 3/0 48,0 4606,0 5350,0
19816 4 G 16 6 23,9 794,0 1450,0
937
Shipwiring and Marine Cables / Lloyds Register
Application
HELUKABEL SHIPFLEX 113 is a new developed and successfully tested screened special drag chain cable which meets the requirements of the strict
standards for application in offshore-areas. This kind of cable combines the feeding cores with the control cores. For this two-line standard there is a
Lloyds Register approval. The outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental
conditions. For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag
chains. Before installation in cable drag chains please read the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
19822 ( 4 G 1,5 + (2 x 1,0)) 11,5 138,0 254,0 - 19830 ( 4 G 6 + (2 x 1,5)) 17,0 358,0 607,0 -
19827 ( 4 G 1,5 + (2 x 1,5)) 12,0 148,0 265,0 - 19826 ( 4 G 10 + (2 x 1,0)) 20,0 574,0 912,0 -
19823 ( 4 G 2,5 + (2 x 1,0)) 13,0 176,0 328,0 - 19831 ( 4 G 10 + (2 x 1,5)) 20,5 584,0 924,0 -
19828 ( 4 G 2,5 + (2 x 1,5)) 14,0 187,0 339,0 - 19832 ( 4 G 16 + (2 x 1,5)) 24,0 825,0 1205,0 -
19824 ( 4 G 4 + (2 x 1,0)) 14,5 258,0 460,0 - 19833 ( 4 G 25 + (2 x 1,5)) 28,5 1283,0 1510,0 -
19829 ( 4 G 4 + (2 x 1,5)) 15,0 268,0 475,0 - 19834 ( 4 G 35 + (2 x 1,5)) 32,0 1850,0 2005,0 -
19825 ( 4 G 6 + (2 x 1,0)) 17,0 348,0 596,0 - 19835 ( 4 G 50 + (2 x 1,5)) 37,0 2540,0 2890,0 -
938
Shipwiring and Marine Cables / Lloyds Register
Application
HELUKABEL SHIPFLEX 121 is a new developed and successfully tested screened special drag chain cable which meets the requirements of the strict
standards for application in offshore-areas. This kind of cable combines the feeding cores with the control cores. For this two - line standard there is
a Lloyds Register approval. The outer sheath insulation of non-adhesive Polyurethan allows the application in extremely oily and rough environmental
conditions. For applications which go beyond standard solutions we recommend that you fill out our especially developed questionnaire for drag
chains. Before installation in cable drag chains please read the installation instructions.
EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
= The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
Part no. No.cores x Outer Cop. Weight AWG-No. Part no. No.cores x Outer Cop. Weight AWG-No.
cross-sec. approx. weight approx. cross-sec. approx. weight approx.
mm mm kg / km kg / km mm mm kg / km kg / km
19836 ( 4 G 1 + 2 x (2 x 0,75)) 12,5 148,0 254,0 - 19841 ( 4 G 10 + (2 x 1,5) + (2 x 1,0)) 22,0 610,0 915,0 -
19837 ( 4 G 1,5 + 2 x (2 x 0,75)) 13,0 170,0 290,0 - 19842 ( 4 G 16 + 2 x (2 x 1,5)) 25,0 904,0 1226,0 -
19838 ( 4 G 2,5 + 2 x (2 x 1,0)) 15,0 229,0 336,0 - 19843 ( 4 G 25 + 2 x (2 x 1,5)) 29,0 1323,0 1595,0 -
19839 ( 4 G 4 + (2 x 1,5) + (2 x 1,0)) 17,0 318,0 485,0 - 19844 ( 4 G 35 + 2 x (2 x 1,5)) 33,0 1621,0 2196,0 -
19840 ( 4 G 6 + (2 x 1,5) + (2 x 1,0)) 18,5 445,0 615,0 - 19845 ( 4 G 50 + 2 x (2 x 1,5)) 37,0 2585,0 2995,0 -
939
CABLE ACCESSORIES
Tools 1002
X
941
CABLE GLANDS
HELUTOP HT-MS
Cable gland 946
HELUTOP MS-EP4
EMC cable gland 950
HELUTOP HT-MS-EX-d
Cable gland, hazardous area, pressure resistant 954
X
943
Cable Glands / made of plastic for standard applications
Note
Details on the individual tests appear in section Dimensions
Technical Information. G Thread size
GL Thread length
SW Spanner size
metric thread
Part no. Part no. Part no. Size Cable Thread Spanner Unit
light grey dark grey black Metr. from / to length size
RAL 7035 RAL 7001 RAL 9005 mm mm mm
93908 93923 93937 M12 x 1,5 3,0 - 6,5 6,0 15 100 -
93909 93924 93938 M16 x 1,5 4,0 - 8,0 8,0 19 50 -
907275 907276 907277 M16 x 1,5 5,0 - 10,0 8,0 19 50 -
92667 92668 92669 M16 x 1,5 5,0 - 10,0 10,0 22 50 -
93910 93925 93939 M20 x 1,5 6,0 - 12,0 10,0 24 50 -
93911 93926 93940 M25 x 1,5 11,0 - 17,0 8,0 29 50 -
93912 93927 93941 M32 x 1,5 15,0 - 21,0 10,0 36 25 -
93913 93928 93942 M40 x 1,5 19,0 - 28,0 10,0 46 20 -
93914 93929 93943 M50 x 1,5 30,0 - 38,0 18,0 60 10 -
93915 93930 93944 M63 x 1,5 34,0 - 44,0 18,0 65 10 -
Continuation
944
Cable Glands / made of plastic for standard applications
NPT thread
Part no. Part no. Part no. Size Cable Thread Spanner Unit
light grey dark grey black NPT from / to length size
RAL 7035 RAL 7001 RAL 9005 mm mm mm
92780 92790 92800 3/8" 5,0 - 10,0 15,0 22 50 -
92781 92791 92801 1/2" 6,0 - 12,0 15,0 24 50 -
92782 92792 92802 1/2" 10,0 - 14,0 15,0 27 50 -
92783 92793 92803 3/4" 13,0 - 18,0 15,0 33 25 -
92784 92794 92804 1" 18,0 - 25,0 18,0 42 20 -
X
945
Cable Glands / made of brass for standard applications
Dimensions
G Thread size
GL Thread length
SW Spanner size
metric thread
Part no. Size Cable Thread Spanner Unit
Metr. from / to length size
mm mm mm
90760 M12 x 1,5 3,0 - 6,5 6,0 14 50 -
99960 M16 x 1,5 5,0 - 10,0 7,0 20 50 -
90762 M20 x 1,5 6,0 - 12,0 8,0 22 50 -
99961 M25 x 1,5 11,0 - 17,0 8,0 27 25 -
94624 M32 x 1,5 15,0 - 21,0 8,0 34 20 -
99962 M40 x 1,5 19,0 - 28,0 9,0 43 5 -
99963 M50 x 1,5 30,0 - 38,0 9,0 58 5 -
90767 M63 x 1,5 34,0 - 44,0 14,0 64 / 68 5 -
906199 M63 x 1,5 44,0 - 55,0 10,0 75 5 -
Continuation
946
Cable Glands / made of brass for standard applications
NPT thread
Part no. Size Cable Thread Spanner Unit
NPT from / to length size
mm mm mm
99965 3/8" 5,0 - 10,0 15,0 20 50 -
99966 1/2" 6,0 - 12,0 15,0 22 50 -
99967 3/4" 13,0 - 18,0 15,0 27 25 -
99968 1" 18,0 - 25,0 17,0 34 10 -
X
947
Cable Glands / for robust applications and special chemical resistance
Note
Details on the individual tests appear in section
"Technical Information". Dimensions
G Thread size
GL Thread length
SW Spanner size
metric thread
Part no. Size Cable Thread Spanner Unit
Metr. from / to length size
mm mm mm
99980 M12 x 1,5 3,0 - 6,5 6,0 14 50 -
99981 M16 x 1,5 5,0 - 10,0 7,0 22 50 -
99982 M20 x 1,5 6,0 - 12,0 8,0 22 50 -
99983 M25 x 1,5 11,0 - 17,0 8,0 27 25 -
99984 M32 x 1,5 15,0 - 21,0 8,0 36 25 -
99985 M40 x 1,5 19,0 - 28,0 9,0 46 20 -
99986 M50 x 1,5 30,0 - 38,0 9,0 60 12 -
99987 M63 x 1,5 34,0 - 44,0 14,0 65 / 68 12 -
PG thread
Part no. Size Cable Thread Spanner Unit
PG from / to length size
mm mm mm
99970 7 3,0 - 6,5 6,0 14 50 -
99971 9 4,0 - 8,0 6,0 17 50 -
99972 11 5,0 - 10,0 6,0 22 50 -
99973 13,5 6,0 - 12,0 6,5 22 50 -
99974 16 10,0 - 14,0 6,5 24 25 -
99975 21 13,0 - 18,0 7,2 30 25 -
99976 29 18,0 - 25,0 8,0 41 20 -
99977 36 22,0 - 32,0 9,0 50 15 -
99978 42 30,0 - 38,0 12,0 60 12 -
99979 48 34,0 - 44,0 14,0 65 12 -
NPT thread
Part no. Size Cable Thread Spanner Unit
NPT from / to length size
mm mm mm
99800 3/8" 5,0 - 10,0 11,5 20 50 -
99801 1/2" 6,0 - 12,0 13,0 22 50 -
99802 3/4" 13,0 - 18,0 13,0 30 25 -
99803 1" 18,0 - 25,0 13,0 40 / 43 10 -
948
Cable Glands / for electromagnetic compatibility (EMC)
X
949