DTMA-1800-UMTS-12-AISG-D: Fullband Double Dual Duplex Tower Mounted Amplifi Er (Masthead Amplifi Er)
DTMA-1800-UMTS-12-AISG-D: Fullband Double Dual Duplex Tower Mounted Amplifi Er (Masthead Amplifi Er)
DTMA-1800-UMTS-12-AISG-D: Fullband Double Dual Duplex Tower Mounted Amplifi Er (Masthead Amplifi Er)
Technical Data
78210990
Type No.
DTMA-1800-UMTS-12-AISG-D (12 dB gain)
Tx Characteristics
Frequency range 1805 - 1880 MHz 2110 - 2170 MHz
Insertion loss Typically 0.5 dB Typically 0.3 dB
Input power (per input) < 100 W (+50 dBm)
Intermodulation products in RX band < -117 dBm (2 Tx carriers at +43 dBm)
Return loss > 18 dB
Rx Characteristics
Frequency range 1710 - 1785 MHz 1920 - 1980 MHz
Return loss > 16 dB (DC ON) / > 12 dB (DC OFF)
Loss in bypass mode Typically 2.3 dB (DC OFF)
Gain 12 dB nominal
Noise figure Typically 1.4 dB
3rd order intercept point (OIP3) Typically 30 dBm
Environmental Characteristics
Operating temperature range -40 ... +65 C
Subject to alteration.
IP rating IP67*
MTBF > 1 000 000 hours (per TMA)
EMC According to ETS 300 342-3
DC and Alarm Characteristics
DC supply 10 - 30 V
Operating current per DTMA Nom. 175 mA at 10 V
(without RET) Nom. 65 mA at 30 V
Alarm management AISG*
Mechanical Characteristics
936.A2903d
KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494
DTMA-1800-UMTS-12-AISG-D
Fullband Double Dual Duplex Tower Mounted Amplifier
(Masthead Amplifier)
Subject to alteration.
734363 100 - 120 mm
734364 120 - 140 mm
734365 45 - 125 mm
936.A2903d
KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-494
DTMA-1800-UMTS-12-AISG-D
Fullband Double Dual Duplex Tower Mounted Amplifier
(Masthead Amplifier)
Mounting Instructions
The coupling torque at 7-16 connectors is 25 - 30 Nm! The tightning torque for fixing
the AISG connector must be 0.5 - 1.0 Nm (hand-tightened).
AISG Setting
Subject to alteration.
The protocol of the software interface can be switched between AISG 2.0 / 3GPP
and AISG 1.1 and vice versa with a vendor specific command (depending on default
setting).
If the primary station does not support the default setting, it has to be switched over
before system start-up. Please contact Kathrein for further information.
Please note
The DTMA is not designed for permanent operation under water. Test conditions for
the IP67 rating: Submerge depth 1 m, submerge time 1 hour.
environmental conditions as described in ETS 300 019-1-4 class 4.1E and have
passed environmental tests as specified in ETS 300 019-2-4. The homogenous
design of KATHREINs tower mounted amplifiers use identical modules and
materials. Extensive tests have been performed on typical samples and models.
The installation team must be properly qualified and also be familiar with the
relevant national safety regulations.