07c Performance Curve 785b Motor 3512

This document contains graphs comparing the torque, rpm, fuel consumption, and brake specific fuel consumption (BSFC) of a Cat 3512B diesel engine. The torque graph shows torque levels ranging from around 1200 to 1525 lb-ft as rpm increases from 1300 to 1850 rpm. The fuel consumption graph shows a consumption rate ranging from around 235 to 283 liters per hour as rpm increases. Finally, the BSFC graph shows BSFC ranging from around 0.337 to 0.345 lbs/hp-hr as rpm increases.

Uploaded by

enrique
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
66 views1 page

07c Performance Curve 785b Motor 3512

This document contains graphs comparing the torque, rpm, fuel consumption, and brake specific fuel consumption (BSFC) of a Cat 3512B diesel engine. The torque graph shows torque levels ranging from around 1200 to 1525 lb-ft as rpm increases from 1300 to 1850 rpm. The fuel consumption graph shows a consumption rate ranging from around 235 to 283 liters per hour as rpm increases. Finally, the BSFC graph shows BSFC ranging from around 0.337 to 0.345 lbs/hp-hr as rpm increases.

Uploaded by

enrique
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

BHP vs RPM Cat 3512B Torque lb-ft Vs Rpm Cat 3412 B

1525 4850

1500 1501 4814


4800 4800
4787
1475
4765
1466
4750
1450

1425 4700
1421

4667
1400
4650

Torque lbs-ft
1375
1368
Bhp

4600

1350

1329 4550
1325
4529

1300 4500

1279
1275
4450

1250

4400
1225 1226
4377

1200 4350
1300 1350 1400 1450 1500 1550 1600 1650 1700 1750 1800 1850 1300 1350 1400 1450 1500 1550 1600 1650 1700 1750 1800
rpm RPM

Consumo Combustible Diesel lts/hr Vs Rpm


BSFC lbs/hp-hr Vs Rpm Caqt 3412 B

0.345 283.0
281.0
279.0 279.0
0.344
277.0
275.0
273.0
0.343
271.0
269.0

0.342 267.0 266.9


265.0
263.0
Consumo Especifico BSFC lbs/hp-hr

0.341 261.0
259.0
Consumo Litros/hr

257.0 257.0
0.34
255.0
253.0
251.0
0.339
249.0 249.1
247.0
0.338 245.0
243.0 243.0
241.0
0.337 239.0
237.0
235.8
235.0
0.336
233.0
231.0
229.0
0.335
227.0 227.1
225.0
0.334 1300 1350 1400 1450 1500 1550 1600 1650 1700 1750 1800
1300 1400 1500 1600 1700 1800 Rpm
Rpm

DIT Manuel Rojas Nadal PRUEBA MANEJO CON TORQUE CFC 785B