Introduction

Rely on the computer hardware, software


and network technique, Tengcontrol Technology Beijing
Econtrolnet
devoted to manufacture industrial automation Technology
products and systems. More than 30 per cent staffs
Beijing Co.,Ltd.
Tengcontrol
are in Research & Development, so we gets strong Technology
ability on product R&D. Tengcontrol Technology Co.,Ltd. Beijing
Tengcontrol
has deep and wide experience on various signal
Automation
acquisition, especially on electric signal acquisition, Beijing Engineering
Tengcontrol Co.,Ltd.
so that, our products are very robust.
Intelligent
Instrument
Technology
Tengcontrol Technology has advanced a Co.,Ltd.
Complete Distributed Network Control System, the
system is constructed via absolutely new theory. It can be applied to construct the SCADA
(Supervisory Control and Data Acquisition), PLC (Programmable Controller) and DCS
(Distributed Control System).

We have sold more than 100 thousands PLC and I/O modules in the last 12 years, and
all are used in various industrial plants and agricultural farms. With customers continuous
testing and our technology improving, Tengcontrol Technology s product are widely
accepted by various users for its excellent network communication, architecture, EMC and
wide temperature adaptation.
Tengcontrol T9 Series PLC 3years warranty
Programmable Logic Controller
Working surrounding: -40 to 85, 5% to 95% relative humidity without condensation, protection IP20
Integrated multichannel AI, AO, DI, DO, PT100, TC , some all in one
Communication 1: one 10M/100M Ethernet port, Modbus TCP protocol, IEC870-5-104 protocol
Communication 2: two RS232/RS485 port, 1 RS485 port, Modbus RTU protocol and Freeport programmingeach channel
is optoelectronic isolated
comply with IEC61311-3 programming
Power supply: 90~264VAC, Max. 12W
Power output: 24VDC, 5 W

PT100 Thermocouple Serial 10M/100M


AI AO DI DO CAN
Product Selection Table /PT1000 input ports Ethernet

T-910 8 2 12 8 3 1

T-910S 8 12 8 3 1

T-910T 8 2 12 8 3 1

T-912 12 4 14 6 3 1

T-919 8 8 4 4 3 1

T-920 2 18 12 2 1

T-921 19 16 2 1

T-930 16 8 2 1 1

T-901 32 2 1 1

T-902 24 2 1 1

T-903 32 2 1 1

T-903S 16 2 1 1

T-906 12 2 1 1

T-907 16 2 1 1

T-950 4 2 14 12 2 1 1

3-Ph AC
T-960 3 1 8 6
measurement
2 1
Tengcontrol SDP Series high 3years warranty

performance PROFIBUS-DP slave I/O module


working surrounding: -20 to 70
Integrated multichannel AI, AO, DI, DO, PT100, TC, some all in one
Communication port 1: PROFIBUS-DP slave port, RS485, optoelectronic isolated, baud rate 187.5KBPS
Communication port 2: Modbus RTU port, RS232, optoelectronic isolated, RS485 is optional
Power consumption: less than 2W
CE, FCC certification, IEC
Installation: standard rail or bolts
Power supply: 24VDC isolated, 5VDC/12VDC/220VAC is optional
Dimension: 12511040(WHD)

Thermocouple MODBUS Profibus


AI AO DI DO PT100
Product Selection Table input Port DP port

SDP100 8 8 8 1 1

SDP101 16 1 1

SDP102 16 1 1

SDP103 16 1 1

SDP104 8 4 1 1

SDP106 8 1 1

SDP112 8 2 8 4 1 1

SDP117 8 1 1
Tengcontrol STC1 Series high 3years warranty
performance MODBUS slave I/O module
working surrounding: -20 to 70
Integrated multichannel AI, AO, DI, DO, PT100, TC , some all in one
communication port: 2 isolated port, default setting is 1 RS232 and 1 RS485, optional can be 2 RS232 or 2 RS485,
Modbus RTU protocol
CE, FCC certification, IEC
Power consumption: less than 2W
Installation: standard rail or bolts
Power supply: 24VDC isolated, 5VDC/12VDC/220VAC is optional
Dimension: 12511040(WHD)
Thermocouple MODBUS
AI AO DI DO PT100
Product Selection Table input Port

STC-1 8 8 8 2

STC-101 16 2

STC-102 16 2

STC-103 16 2

STC-104 8 4 2

STC-106 8 2

STC-110 4 4 4 1

STC-112 8 2 8 4 2

STC-117 8 2
Tengcontrol technology 3years warranty
electrical products
working surrounding: -40 to 85

Integrated multichannel AI, DI, AO, DO, Relay Protection and communication in one product

inputs: Three phase or three circuit voltage, three phase or three circuit current, calculate three phase or three circuit active

power, three phase or three circuit reactive power, three phase total active power, three phase total reactive power, line

frequency, power factor, 1 to 31 harmonics(STC-2XB), zero-sequence current, etc. high data refresh speed, voltage, current

and power resolution 0.5%FS, voltage measurable range 0 to 400VAC, AC current input 0 to 5A/1A, both the voltage and

current are isolated via on-board voltage and current transformer.

communication port: 2 isolated port, default setting is 1 RS232 and 1 RS485, optional can be 2 RS232 or 2 RS485, Modbus

RTU protocol

Surface Mounting Technology, high Electromagnetic Compatible

rail or bolts installation

IEC

Serial 3-Ph AC LED Comm. port


AI DI DO Protection
Product Selection Table ports measurement indication isolation

STC-2 2 6 3 2

STC-201 2 6 3 2

STC-203 2 2

STC-204 4 6 4 2

NPM-502 2

MDS-101 2 6 3 2

MDS-104 4 6 4 2
3years warranty

TengControl Technology Industrial


Communication Products
PROFIBUS DP, MODBUS, MODBUS TCP protocol conversion
Freeport programming
working surrounding: -40 to 85

Programmable, support CAN free port, serial


TG900P port free port, IEC875-5-104 protocol / MODBUS
protocol conversion

CAN to the serial port, Ethernet port,serial


port to the Ethernet port protocol conversion,
TG900 port function can be flexibly configured, cost-
effective, easy to use

The PROFIBUS /MODBUS protocol gateway,


TG7530 PROFIBUS-DP slave, MODBUS RTU master

EC7520
RS485 to RS232 communication conver ter,
photoelectric isolated interface converter

Serial port 2 /
Serial port 1 / eth MODBUS/
eth MODBUS/ MODBUS TCP
MODBUS TCP

RS485
Serial port 3 MODBUS