ProductSpecification03341

(RevisionNEW,10/2006)

EDMHD
ElectronicDistributorModuleHeavyDuty

Application
The OH systems for compressed natural gas
include an engine control with ignition control. In Can fire up to 6
the OH1.2 system, the EDM-HD is a replacement
for the ICM which works with the ECM control. In cylinders
the OH2.0 system, the EDM-HD works with the Engine mountable
PCM-128HD control. Please note that the PCM-
128HD is not compatible with the ICM. The EDM- Ignition coil
HD will also work with the ECM control for the new diagnostics
OH1.2MD system.
Integrated,
Description environmentally
sealed Deutsch
The EDM-HD is an ignition coil driver that takes cylinder firing commands from an
engine controller. The EDM-HD is capable of firing up to six ignition outputs. The
DT connector
EDM-HD interfaces with the OH1.2, OH1.2MD, and OH2.0 control modules (ECM in Backwards
OH1.2/OH1.2MD, PCM128-HD in OH2.0). The control modules provide a Trigger
pulse train and a Reset pulse train. On a 6-cylinder engine, the Trigger line pulses
compatible with
six times for every Reset pulse. The control module reads an Imon feedback signal ICM
from the EDM-HD.
Flexible across
The Imon feedback signal allows the control modules to perform diagnostics on the Woodward OH
EDM-HD and also allows the control modules to adjust the Trigger pulse timing to systems (1.2,
minimize the ignition coil current draw and consequent self-heating of the EDM-HD
semiconductor switches and the ignition coils. 1.2MD, 2.0)
The EDM-HD is designed to drive the low side of an inductive ignition coil as 12 V and 24 V in
illustrated in Figure 1. The low side of the inductive ignition coil primary is one part number
connected to one of the low side switch outputs on the EDM-HD. When commanded
by a control module, the EDM-HD turns on the low side switch, which allows current Use with
to be pulled from the battery positive through the ignition coil through the EDM-HD Woodward
low side switch and back through battery negative. The secondary of the inductive approved ignition
ignition coil does not go high until the low side switch is turned off and the inductive
coils only
coil is allowed to fly back. A semiconductor clamp internal to the EDM-HD limits the
ignition coil primary flyback voltage.
Woodward 03341 p.2

Specifications
Power Requirements
Nominal Operating Voltage Range: 1032 V
Transient Voltage Range: 632 V
EDM-HD Logic Current (worst case): 100 mA max
Coil RMS Current (worst case): 4 A (rms) max with a repetitive 7.5 A peak max
Recommended Fusing
(for 6 Woodward coils): 7.5 A Fast Blow Automotive Style Fuse
Ignition Coils
Intended for use with Woodward-approved ignition coils for both 12 V and 24 V applications.
Contact Woodward for uses with other inductive ignition coils.
ICM Backwards Compatibility
The EDM-HD maintains timing accuracy that is 0.5 of the ICM (0096-00-000 Rev L).
Environmental Requirements
Engine-mount operation without vibration isolators
Random Vibration Test
The EDM-HD meets Woodwards RV3 random vibration specification (22.1 Grms / 3 hours per axis) per
Woodward procedure 3-04-6231.
Heated Vibration Test
The EDM-HD operates without interruption in 24-hour, 105 C, engine vibration test.
Shock Test
The EDM-HD meets mechanical shock per Woodwards procedure 3-04-6231 (MS1 per MIL-STD 810F, Method
516.5, Procedure 1, 40 G Peak, 11 ms duration sawtooth pulse).
Shock-Drop Test
The EDM-HD can survive being dropped from 0.9 m onto a concrete floor.
Temperature
Ambient Operating Temperature: 40 to +105 C
Mounting Surface Temperature: 40 to +105 C
Heat Soak/ Storage Temperature Range: 40 to +105 C
Thermal Shock Test
250 non-operating thermal cycles between 40 and +105 C, with a dwell of 1.5 hours at each temperature.
Thermal Endurance / Humidity Test
1000-hour, operational, thermal cycling (40 to +105 C) endurance test followed by a 120-hour operational
humidity cycle test
Ingress Protection Test (Spray Test)
IEC529 IPX6 spray testing: 12.5 mm nozzle delivering 100 L/min at a distance of 2.53 m, sprayed on all sides
for 3 minutes
Water Immersion Test
Unit preheated to 105 C for two hours, then immersed in room temperature (~18 C) water for five minutes.
Connector pins are not immersed.
Salt Spray Test
Salt spray per MIL STD 810D, Method 509.2, Procedure I, Aggravated Screening (5 percent solution of NaCl at
35 C for 48 hours).
Chemical Compatibility
Tested for exposure to: diesel fuel, lubricant oil, brake fluid, antifreeze solution, transmission oil
Abnormal Conditions / Wiring Fault Robustness
Start Voltage: Logic circuits work down to 6 V battery voltage
Reverse Voltage: Can survive reverse voltage of 32 V applied to Vbat+ for 5 minutes
Short to Battery Minus: Each pin on the EDM-HD connector can be shorted to battery minus
without causing permanent damage to the EDM-HD hardware
Short to Battery Plus: Each pin on the EDM-HD connector can be shorted to battery plus
without causing permanent damage to the EDM-HD hardware
Jump Start/Alternator Regulator Failure: Can survive 36 V applied to Vbat+ for 5 minutes
Woodward 03341 p.3

Figure 1. EDM-HD / Inductive Coil Simplified Block Diagram

Figure 2. EDM-HD with 3-hole to 4-hole Mounting Bracket (top view)


(Mounting Bracket only needed for installations with ICM 3-bolt mounting pattern)
Woodward 03341 p.4

Figure 3. EDM-HD Six Cylinder System Connections

EDM-HD Part Numbers


8408-012 EDM-HD for 6-cylinder engines
5404-1048 6-cylinder adapter harness for OH1.2 retrofit applications
8923-1238 Mounting kit / bracket (for installations with ICM 3-bolt mounting pattern)

For more information contact:


PO Box 1519, Fort Collins CO, USA 80522-1519
1000 East Drake Road, Fort Collins CO 80525
Tel.: +1 (970) 482-5811 Fax: +1 (970) 498-3058
www.woodward.com

Distributors & Service


Woodward has an international network of distributors and service facilities.
For your nearest representative, call the Fort Collins plant or see the
Worldwide Directory on our website.

This document is distributed for informational purposes only. It is not to be construed as


creating or becoming part of any Woodward contractual or warranty obligation unless
expressly stated in a written sales contract.
Copyright Woodward 2006, All Rights Reserved