The newest member of the high-performance Beckman Coulter laboratory analyzer


series is the AU680 Chemistry System. Based on in-depth customer consultation, the
AU680 Chemistry System is intended to help medium to high throughput laboratories
meet ever increasing pressures on time and productivity.
The benefits of the AU680 Chemistry System can be divided into three main
categories improved user convenience including automation options; extended
analytical reach and reduced operating costs. Regarding convenience, the AU680
Chemistry System is operated through a new and highly intuitive graphical user
interface, including embedded videos to support key maintenance steps. Flexibility is
assured with a menu capacity of up to 63 different assays on board. A new special
priority lane performs re-runs quickly. To increase automation levels, samples can be
loaded via a new standardized rack tray for direct transfer from the Beckman Coulter
AutoMate 2500 peri-analytical workstation.

Triple reagent dispensing enables the AU680 Chemistry System to perform assays
requiring up to three separate reagents. This enhances analytical performance and
opens up new possibilities for current and future assays. Overall, operating costs are
reduced by eliminating the need for multiple calibrators via Plug and Play calibration
using 2D barcodes.

Finally, the AU680 Chemistry System offers a speed of up to 1200 tests per hour and
an on-board capacity of up to 63 different tests in parallel. Profit from innovative
features and clear benefits for your lab!

Improved convenience
New and intuitive graphical user interface
Excellent overview and precise software guidance
Embedded maintenance video

New analytical horizons

Handling of 3-shot reagents

Plug and play calibration via 2D barcode

Minimized reagent volumes


Eliminates need for multiple calibrators
Applies to C3, C4, Transferrin and ASO

Sample feeder

Positive sample identification to eliminate any sample mix ups


Beckman Coulter flexible racks to handle all commonly used tube sizes in parallel
Barcoded racks to define different sample materials or other sample specifics
150 samples on board at any time for long walk away
Reflex testing
Priority re-run lane

Refrigerated reagent compartments


Real workstation consolidation with up to 60 different analytes in parallel
Ready to use liquid stable reagents
Automatic bottle switch capabilities
Advanced calibration
Liquid detection and remaining test number calculation

Washing station

High tech wash station to ensure a valid diagnostics


Two different detergents to prevent any carry over
Four fold water cleaning followed by a separate drying step to gain optimum system
performance

Mixer

High precision mixer station to ensure excellent reaction conditions


Standardized mixing procedures across the whole range of analyzers
Different mixer positions for individual reaction steps

Cuvettes wheel

Non disposable quartz cuvettes


Software driven carry over elimination
Total reaction volume as small as 120 l
Environmental friendly
ISE unit

High quality ISE for Na, K and Cl


6 months shelf life
18 months shelf life for reference electrodes
600 tests/hour (if ISE mode only)
Same technology across the whole range of analyzers

Sample probe

Sample volume as small as 1.6 l


Clot detection
Crash prevention
Sampling frequency of 4.5 seconds

STAT sample rotor

Dedicated STAT rotor with 22 positions and integrated barcode reader


Full STAT capabilities during routine operation
Refrigerated area for calibrators and controls
Combined routine and emergency work area
Reagent probes

Tact frequency 4.5 seconds


Reagent volume as small as 15 l
Liquid detection
Calculation of remaining tests/vial

Specifications
Analytical system Fully automated, random-access chemistry system with
STAT capability
Analytical principle Spectrophotometry and potentiometry
Analytical types Endpoint, rate, fixed point and indirect ISE
Analytical methods Colorimetry, turbidimetry, latex agglutination,
homogeneous EIA, indirect ISE
Simultaneously processed 60 photometric tests + 3 ISE
analytes

Throughput 800 photometric tests/hour; up to 1,200 with ISE


Sample types Serum, plasma, urine, whole blood (HbA1c) and other
fluids
Sample feeder Racks with 10 samples each (bar codes on primary
tubes and on racks); capacity of 150 samples;
continuous loading
Sample tubes In primary and secondary tubes; diameter between 11.5
and 16.5 mm; height between 55 and 102 mm
STAT samples Up to 22 positions for STAT samples, bar-coded
primary tubes
Sample volume 125 L in 0.1 L increments (125 L for repeats)
Reagent supply 60 positions for R1, 48 positions for R2; (refrigerated
412 C), handling of 3-shot reagents
Reagent volume R1: 15250 L; R2: 15250 L; (in 1 L increments)
Total reaction volume 120425 L
Reaction cuvette Quartz cuvettes
Reaction time Up to 8 minutes, 40 seconds
Reaction temperature 37 C
Mixing method With rotating paddles after dispensing sample and
reagent
Photometry system Direct assay through the reaction cuvette (0 3.0 OD)
mono and bichromatic measurements possible
Wavelength 13 different wavelengths between 340 800 nm
Cuvette cleaning Comprehensive cleaning with detergents
Calibration Autocalibration, cooled calibrator positions; master
calibration established by two-dimensional bar code of
the reagent bottle (>3-point calibration)
Quality control Auto QC, cooled QC positions
Test requisition Individual and profile test requisition via on line,
mouse, functions keys or touch screen
Safety Clot detection and crash prevention for sample and
reagent dispenser
Online Full uni- and bidirectional communication possible
Software Windows XP
Data Storage Sample number 100,000 samples. Reaction Data
200,000 tests
Dimensions (W x H x D) mm ANL 1,950 x 1,280 x 1,000
Power supply 200 V; 208 V; 220 V; 230 V; 240 V; 50 Hz; 60 Hz/3.8
KVA