Marinediesels - Co.uk - Members Section Starting and Reversing MAN B&W Air Start Distributor Operation

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

The MAN B&W radial air start distributor valve operation http://www.marinediesels.co.uk/members/starting_&_reversing/MAN...

marinediesels.co.uk - Members Section


Starting and Reversing
MAN B&W Air Start Distributor Operation

Other Pages The Basics The 2 Stroke Engine The 4 Stroke Engine Operation Members

There is one pilot valve for each air start valve. Each pilot
valve has 3 inlet ports and one outlet port. When the engine
is required to start, Pilot air at 30 bar from the main air
start manifold is led to the middle inlet port.

The air cannot pass through the pilot valve at this point
because the port is shut off by the operating piston on the
valve slide.

If the engine is required to start ahead then control air at 30


bar from the air start manifold is led to the top port. This
acts on the top of the operating piston of the valve slide
and forces the valve slide down onto the inner cam profile.
As the slide moves downwards to admit pilot air to the air
start valve, the top port is closed off and the main pilot air
now acts on top of the actuating piston. As it does this, the
pilot air passes through the exit port to actuate the air start
valve in the cylinder.

1 of 2 06-02-2017 22:36
The MAN B&W radial air start distributor valve operation http://www.marinediesels.co.uk/members/starting_&_reversing/MAN...

As the cam profile moves the valve slide upwards, the


piston on the operating slide closes off the pilot air and air
to the air start valve is vented through the centre of the
valve slide.

For astern operation the action is similar, but this time the
control air enters through the lower port.

DHTML Menu / JavaScript Menu Powered By OpenCube

2 of 2 06-02-2017 22:36