There is one pilot valve for each air start valve. Each pilot
valve has 3 inlet ports and one outlet port. When the engine
is required to start, Pilot air at 30 bar from the main air
start manifold is led to the middle inlet port.
The air cannot pass through the pilot valve at this point
because the port is shut off by the operating piston on the
valve slide.
1 of 2 06-02-2017 22:36
The MAN B&W radial air start distributor valve operation http://www.marinediesels.co.uk/members/starting_&_reversing/MAN...
For astern operation the action is similar, but this time the
control air enters through the lower port.
2 of 2 06-02-2017 22:36