Thermax Boiler
Thermax Boiler
Thermax Boiler
08 December, 2015
Vinod Desai
Thermax - Chemical Division
THERMAX LIMITED
Contents
Water Chemistry w.r.t. Boiler
Problems associated w.r.t. Water chemistry
Objective and importance of boiler water treatment
Various programs in boiler water treatment
Dosing of chemicals and monitoring
THERMAX LIMITED
Water Chemistry
THERMAX LIMITED
IMPURITY
THERMAX LIMITED
IMPURITY
Calcium/Magnesium Scaling
Sodium/Potassium Corrosion
Chloride/Sulfate Corrosion
Carbonates/Bicarbonates Scaling/Foaming
Hydroxides Scaling/Foaming
Silica Scaling/Deposition
THERMAX LIMITED
IMPURITY
OTHERS
THERMAX LIMITED
Water- impurities related problems in Boiler
THERMAX LIMITED
SCALING
THERMAX LIMITED
INADEQUATE MAKE UP WATER QUALITY
SCALING
METAL LOSS,PITTING
LOSS OF PROTECTECTIVE OXIDE FILM
LOW pH (DESIRED PROTECTECTIVE FILM IN BOILER
DISSOLVED OXYGEN
IS MAGNETIC IRON OXIDE, Fe3O4. OXYGEN
DESTRUCTS THE PROTECTIVE OXIDE FILM)
Fe3O4 + O2 --> 6 Fe 2O3
THERMAX LIMITED
THERMAX LIMITED
THERMAX LIMITED
CORROSION
THERMAX LIMITED
CORROSION
CONDENSATE CORROSION
BICARBONATES + HEAT CO2
CARBONDIOXIDE CO2 + H2O H2CO3 ( CARBONIC ACID)
Fe + H2CO3 Fe (CO3)2
THERMAX LIMITED
THERMAX LIMITED
MECHANICAL
HIGH WATER LEVEL
INCOMPLETE SEPARATION
OF STEAM& WATER
HIGH STEAMING RATE CARRYOVER
BOILER DESIGN
UNEVEN FIRE DISTRIBUTION
LOAD FLUCTUATIONS
CHEMICAL
HIGH TDS (TOTAL DISSOLVED
SOLIDS)
HIGH ALKALINITY
LEAKAGE OF OIL /
ORGANICS
THERMAX LIMITED
TURBINE DEPOSITS
THERMAX LIMITED
TURBINE
CORROSION CARRYOVER
MU
CORROSION
SCALING
DEAERATOR
BOILER BD
CORROSION
FW
External treatment
Internal treatment
THERMAX LIMITED
EXTERNAL TREATMENT
OXYGEN CHLORINE
SETTLING CLARIFICATION
DEAERATOR ACTIVATED
FILTERATION CARBON
SOFTENING DEMINERALISATION
RO
THERMAX LIMITED
INTERNAL TREATMENT - OBJECTIVE
THERMAX LIMITED
Internal Treatment - Need
THERMAX LIMITED
INTERNAL TREATMENT- INSURANCE
THERMAX LIMITED
Internal Treatment
Steam
MU
Safety,
Reliability
Efficiency
DEAERATOR
BOILER CBD
THERMAX LIMITED
Internal Treatment - Various Programs
THERMAX LIMITED
Oxygen Scavenger
THERMAX LIMITED
Features of oxygen scavenger
Oxygen scavenging
Metal Passivator
Volatile compound
Organic Treatment
THERMAX LIMITED
Blend of Neutralizing
Amines
THERMAX LIMITED
Different types of Amines
Morpholine
Cyclohexylamine
Diethyl-aminoethanol ( DEAE )
Methoxypropylamine
Amino Butanol
THERMAX LIMITED
Function of Neutralizing Amines
THERMAX LIMITED
While selecting any neutralizing amine program, three factors
are to be considered.
THERMAX LIMITED
Standard boiler water treatment
Combination of
Oxygen scavenger
Neutralizing amine
THERMAX LIMITED
DOSAGE
OXYGEN SCAVENGER
- Based on Feed water temperature
SCALE / CORROSION INHIBITOR
- Based on PO4 residual to be
maintained in boiler/ on blowdown
NEUTRALIZING AMINE
- Based on pH of BFW/BW/Condensate
water
THERMAX LIMITED
Boiler Treatment recommended Chemical Feed Points
1 S
3
MU
DEAERATOR
2 BOILER BD
FW
Phosphate - 3
OS - 2
Amine - 1 or 1 and 2
THERMAX LIMITED
ALL VOLATILE TREATMENT
THERMAX LIMITED
FUNCTION OF AVT
Filming amine
Dispersing amine
Neutralization amine
THERMAX LIMITED
PROTECTIVE FILM BARRIER
AMINE FILM
N R
N R
N R
WATER
METAL
SURFACE
LEGEND
N R = AMINE MOLECULE
N+ = AMINO GROUP
R- = ALKYL GROUP
THERMAX LIMITED
NEUTRALIZING REACTION
THERMAX LIMITED
BENEFITS OF AVT
BETTER EASIER
THERMAX LIMITED
LIMITATIONS OF AVT
Primarily used in Power boilers where make water is 99%
steam condensate ( Pure water)
High purity Feed water is mandatory MB-DM Make up and
non-contaminated condensate
Increases load on CPU and reduces life of Resin
Excess level of Ammonia accelerate Copper corrosion
Low boiler water pH ( 8.4 to 8.8 ) - chances of Silica carry
over to turbine
No protection from Chloride attack as no buffer alkalinity is
available
Non acceptance of pH range of 8.4 to 8.8 by boiler
manufacturer
No authenticated recommendation by boiler manufacturers,
Boiler Regulatory Authorities.
THERMAX LIMITED
Dosing Procedure
THERMAX LIMITED
Blow-down
CBD ( Continuos blowdown )
- To remove concentrated water continuously
- Located in the area of highest boiler water concentration
Preferred way of blowdown as minimal loss of water
and heat recovery of heat content by use of blowdown
flash tank
THERMAX LIMITED
One has to select the appropriate chemicals from mentioned list
to use it as program
Boiler pressure
Application of the steam
Feed water pre-treatment
Feed water quality
Boiler operating conditions (like feed water
temperature, % blow down, etc.)
Customer requirement
THERMAX LIMITED
Monitoring
.
Monitoring of the treatment consists of
THERMAX LIMITED
WATER ANALYSIS
Calibration of instruments
THERMAX LIMITED
Parameters to be analyzed
pH
Conductivity/TDS
Phosphate
Sulfite/Hydrazine
Silica
Alkalinity
Chloride
Iron
Residual Amine (incase of AVT)
THERMAX LIMITED
Preservation
Wet preservation ( Boiler under shut for approx. less than month )
Dry preservation
After complete drying either of the following desiccants to be used
- Quicklime @ 6 lb / 100 ft3 of boiler volume
- Silica gel @ 17 lb / 100 ft3 of boiler volume
- Activated alumina @ 27 lb / 100 ft3 of boiler volume
THERMAX LIMITED
THERMAX LIMITED