103k2000 2
103k2000 2
103k2000 2
CIRCUIT DRAWN WITH POWER SUPPLY OFF FOR TYPICAL REMOTE CONTROL
M 2
2 DETAILS, SEE DOCUMENT
3
3 V
4
1
3
PHASE
RWS102
SUPPLY
U
3 1 TR AN S F OR ME R TAP P IN G OP TION S
6
5 T ap Nominal 50/60Hz
U V W E TYP E 1
FS1
W 220/230
X 380/400
C1 C2 Y 400,415/420
U W X Y Z
Z 440/460
F US E F S 1= 250mA A NTI-S UR G E
SK2 TYP E 2
0VAC 1 W 346/380
TRANSISTOR SWITCHING FOR
PS1 X 480/500
24VDC CONTACTORS (IQ10-35) 120VAC 4
RELAYS ONLY FITTED WHEN Y 240/240
0VDC
120VAC CONTACTOR IS FITTED 3 4 Z 550/575
24VDC
FOR IQ40,70,90,91 & 95 24VDC 6 F US E F S 1= 250mA A NTI-S UR G E
_ 5 NOMINAL SUPPLY
+
(OUTPUT)
TYP E 3
SK14
X 660/660-690
0VDC 1
INTERNAL SUPPLY Y 690/-
24VDC FOLO / CPT PCB F US E F S 1= 150mA A NTI-S UR G E
2
SK13
26 WAY
REFER TO SHEET 2 FOR NOTES
& OPTION PCB'S IF FITTED
OPEN
REMOTE OPEN INTERLOCK 13 37
CLOSE INTERLOCK 14 38
COMMON -VE 5 31
SK1 SK2
SLOT A SLOT B
SLOT A
SK1
SLOT A SK3
-VE +VE
1 23 A
2 22
DEMAND +VE 3 26
COMMON -VE 4 27 } ANALOGUE INPUT SIGNAL
FOR FOLOMATIC
FOLOMATIC /
NO CONNECT 5
CPT
MANUAL/AUTO 6 39
COMMON -VE 24VDC 7 41
COMMON -VE 120VAC 8 45
SK6
1 0V
2 24V SUPPLY FROM SK14 ON POWER PCB
SK8
1
2
SLOT B
SK2
SLOT B SK2
1 15 2 WIRE A (IN)
(REFER TO MANUAL
2 18 2 WIRE B (OUT)
PAKSCAN F.C.U.
PUB059-019)
3 28 2 WIRE C (COMMON)
7 29 SCREEN
30
E
ISOLATOR
DC
DC
NOTES
1.FUSES:
-PS1 is a self-resetting fuse. 3.INDICATION:
-Refer to publication PUB002-039 for approved fuses FS1 and FS2. -For typical position, status and alarm indication see PUB002-041.
-Actuator rated voltage specified on nameplate. Voltage tolerance +/-10%, -S contacts are user configurable and are shown in their default
applies for rated torque performance; duty cycle is not guaranteed. setting.
2.REMOTE CONTROL: -Refer to PUB002-040 for functions and configuration instructions.
-For typical remote control circuits refer to: -Monitor Relay indicates actuator availability for remote control (shown
-RWS indicated or PUB002-041. unavailable). It can be configured to exclude local/remote selection.
-For DC and AC control, connect ve/0V to terminal 36. -Refer to PUB002-040 for monitored functions and configuration
-(For negative switch / positive common, refer to RWS indicated). instructions.
-Control signal threshold voltages: -Voltage applied to indication contacts must not exceed 150Vac
-DC: on 16Vdc / off 8Vdc, max 60Vdc. -Individual Switch current must not exceed 3.5A inductive, 5A resistive
-AC: on 60Vac / off 40Vac, max 120Vac. and no more than 8A in total for all 4 contacts.
-Control signal duration to be 300ms minimum.
-Maximum current drawn from remote control signals is: 4.BATTERY:
-8mA at 24Vdc or 12mA at 120Vac. -Battery maintains local and remote S contact indication only.
-Supply provided on terminals 4 & 5: -Refer to installation manual for approved replacement battery types.
-Intended for remote control. Circuit Diagram Number Issue Sheet
-Max external load 5W at 24Vdc / 5VA at 120Vac No
103K2000 2 2
See Sheet 1 for all Revision details/information of 2
IQ3