0% found this document useful (0 votes)
249 views2 pages

Codix 553

The CODIX 553 is a process controller with the following key features: 1) It has inputs for current (0-20mA, 4-20mA) and voltage (0-10V, 2-10V, ±10V) with 24 programmable control points and can display and hold or reset limit values. 2) It has two programmable limit outputs that can be set as relays or optocouplers. 3) Optional interfaces include RS232, RS485, and RS422 and it has an auxiliary power supply output to power sensors.

Uploaded by

Carlos Rodrigo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
249 views2 pages

Codix 553

The CODIX 553 is a process controller with the following key features: 1) It has inputs for current (0-20mA, 4-20mA) and voltage (0-10V, 2-10V, ±10V) with 24 programmable control points and can display and hold or reset limit values. 2) It has two programmable limit outputs that can be set as relays or optocouplers. 3) Optional interfaces include RS232, RS485, and RS422 and it has an auxiliary power supply output to power sensors.

Uploaded by

Carlos Rodrigo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Process controller

CODIX 553 with 2 limit values

Your benefit Input range


Programmable input characteristic curve 0 ... 20 mA, 4 ... 20 mA; 0 ...10 V
with up to 24 control points 2 ... 10 V; +10 V
Display-Hold or reset input for the limit Outputs
values 2 limit values with programmable hysteresis
Very big keys for use with gloves and programmable signal behaviour, relays
Input for key-look with change-over contact or optocoupler
very bright display More advantages
erial Auxiliary power supply output for
able with s measuring transducer/sensor
avail -up
Now e and set optional serial interface
fa c ol!
inter e EzContr
w ar
soft
Technical data
Miscellaneous Data Weight approx. 220 g
Display 5 digit red LED 14.2 mm high Protection IP 65 (front)
Display range 19999 ... 99999, with leading zeros suppression Ambient temperature 20 ... +65 C
Out of Range Indication Under-range uuuuu / Over-range ooooo Storage temperature 40 ... +85 C
Data storage EEPROM, 1 Million storage cycles or 10 Years Digital inputs
Test voltages EN 61010 Part 1 ; overvoltage category 2, level 2 Input MPI* Function of the inputs depending on set up
EMC Interference emissions EN 50081-2 / 1. Function Display-Hold to stop the instantaneous value
EN 55011 Class B 2. Function Reset Reset the alarm value
Interference resistance EN 61000-6-2 Alarm Latch
AC power supply 90 ... 260 V AC/max. 6 VA
external fuse 100 mA/T Outputs
DC power supply 10 ... 30 V DC, max. 2 W, galvanically isolated Alarm 1/Alarm output 2
with inverse polarity protection Relay output with volt-free changeover contacts can be
external fuse 250 mA/T setup as normally closed or normally open
Mains Hum Filter digital filter 50 Hz or 60 Hz, programmable Switching voltage 250 V AC/300 V DC
Measurement ranges Switching current max. 3 A AC/DC, min. 30 mA DC
Current input (DC) Ranges 0 ... 20 mA, 4 ... 20 mA Switching power 2000 VA / 50
Resolution 2 A or NPN-ooptocoupler with open collector and open emitter
Voltage drop max. 2 V bei 20 mA Switching power 30 V DC/15 mA
Max. current 50 mA Auxiliary power supply output for measuring transducer/sensor
Voltage input(DC) Ranges 0 ... 10 V, 2 ... 10 V, 10 V AC models voltage output 10 V DC 2%, 30 mA and
Resolution 1 mV voltage output 24 V DC 15%, 50 mA
Input resitance > 2 M DC models only voltage output 10 V DC 2%, 30 mA
Max. voltage 30 V Interface
Measuring speed approx. 2 measurements/s Available options RS232, RS485, RS422
Linearity < 0,1% 1 Digit for the whole measuring Baud rate 600, 1200, 2400, 4800, 9600, 19 200 programmable
range at an ambient temperature of 20C Address
*MPI: Multi Purpose Input 00 ... 99 programmable
Zero calibration automatic
Temperature drift 100 ppm/K

Dimensions:

Panel cut-out

26 www.kuebler.com
Process controller

Connections:
Rear side view Power supply and alarm outputs
Measuring- and Relay output 7
X2 control inputs as OUT 2 OUT 1 8
X1
well as auxiliary 1 2 3 4 5 6 7 8
signals
X1

Power supply and


X3 Optocoupler output 7
limit outputs
X1 OUT 2 OUT 1 8

Interface 1 2 3 4 5 6 7 8

DC version AC version
Current measurement
7 10 ... 30 V DC 90 ... 260 V AC (N~)
8 GND4 (0 V DC) 90 ... 260 V AC (L~)

+ -
X2
1 2 3 4 5 6 7 8 9 10 11

1 Current input (I)


0 ... 20 mA / 4 ... 20 mA
2 GND1 (Analog) Control inputs and auxiliary power supply (Uout)

9 9 GND3 (for Uout)


Voltage measurement 10 10 Uout +10 V/30 mA
1
11
1 11 Uout +24 V/50 mA only for power supply
1
X2 90 ... 260 V AC
X2 1 2 3 4 5 6 7 8 9 10 11 8 MP-Input "Reset-Alarm-Latch/
- +
1 2 3 4 5 6 7 8 9 10 11 Display-Hold
1 Alternatively connect directly 7 GND2 (KEY/MPI)
2 GND1 (Analog) to DC supply (galvanic 6 Keypad lock-out "Key"
3 Voltage input (U) separation of control and
0 ... 10 V, 2 ... 10 V, -10 ... +10 V measurement inputs)

Interface Application: Serial interface


Level measurement For data transmission and documentation
X3 1 2 3 4 5 Flow measurement Connection for programmable logic
RS232 RS485 RS422 Pressure measurement controllers
1 GND Revolution measurement Programming via PC
2 RxD DO+/RI+ RI+
3 TxD DO/RI RI
4 DO+
5 DO

Delivery includes: Order code:


Process display 6.553.01X.X0X
Screw terminal, 8-pole, RM 5.08 Interface
Screw terminal, 11-pole, RM 3.81 0 = without interface
Screw terminal, 5-pole, RM 3.81(*) 5 = RS232
Clamping bracket 6 = RS422
Gasket 7 = RS485
Multilingual operating instructions Supply voltage
1 set of self-adhesive symbols 0 = 90 .. 260 V AC
* only with the interface option 3 = 10 .. 30 V DC
Alarm output
0 = relay
1 = optocoupler
www.kuebler.com 27