Software Verification
PROGRAM NAME: SAP2000
REVISION NO.: 0
NTC 2008 Example 002
P-M INTERACTION CHECK FOR COMPRESSION-CONTROLLED RECTANGULAR COLUMN
EXAMPLE DESCRIPTION
The Demand/Capacity ratio for a given axial loading and moment is tested in this
example.
In this example, a reinforced concrete column is subjected factored axial load N
= 2174 kN and moment My = 544 kN-m. This column is reinforced with 5-25
bars. The design capacity ratio is checked by hand calculations and computed
result is compared. The column is designed as a short, non-sway member.
GEOMETRY, PROPERTIES AND LOADING
2174 kN
My= 544 kN-m
550mm
A A 60 mm 350mm
3m
Section A-A
Material Properties Section Properties Design Properties
Ec = 25x106 kN/m2 b = 350 m fck = 25 MPa
= 0.2 d = 490 mm fy = 460 MPa
G = 10416666.7kN/m2
NTC 2008 Example 002 - 1
Software Verification
PROGRAM NAME: SAP2000
REVISION NO.: 0
TECHNICAL FEATURES TESTED
Tied Reinforced Concrete Column Design
RESULTS COMPARISON
Independent results are hand calculated and compared.
Percent
Output Parameter SAP2000 Independent Difference
Column Demand/Capacity Ratio 1.005 1.00 0.50%
COMPUTER FILE: EN 2-2004 Ex002
CONCLUSION
The computed results show an acceptable comparison with the independent
results.
NTC 2008 Example 002 - 2
Software Verification
PROGRAM NAME: SAP2000
REVISION NO.: 0
HAND CALCULATION
COLUMN STRENGTH UNDER COMPRESSION CONTROL
fcu = 25 MPa fy = 460 MPa
b = 350 mm d = 490 mm
1) Because e = 250 mm < (2/3) d = 327 mm, assume compression failure. This assumption will
be checked later. Calculate the distance to the neutral axis for a balanced condition, cb:
Position of neutral axis at balance condition:
700 700
cb = dt = ( 490) = 296 mm
700 + f y 700 + 460
2) From the equation of equilibrium:
N = Cc + C s T
where
f ck 0.85 30
Cc = ab = 350a = 5950a
c 1.5
As' f ck 2500 0.85 30
fy - = 1.5
Cs = 460 - = 963, 043 N
s c 1.15
Assume compression steels yields, (this assumption will be checked later).
= 2174 f s ( f s < f y )
Af 2500 f s
T= s s=
s 1.15
N1 = 5,950a + 963, 043 - 2174 f s (Eqn. 1)
3) Taking moments about As:
1 a
( )
N 2 = ' Cc d - + Cs d - d '
e 2
The plastic centroid is at the center of the section and d " = 215 mm
e' = e + d " = 250 + 215 = 465 mm
1 a
N2 = 5950a 490 - + 963, 043 ( 490 - 60 )
465 2
NTC 2008 Example 002 - 3
Software Verification
PROGRAM NAME: SAP2000
REVISION NO.: 0
N 2 = 6270a - 6.3978a 2 + 890,556 (Eqn. 2)
4) Assume c = 365 mm, which exceed cb (296 mm).
a = 0.8 365 = 292 mm
Substitute in Eqn. 2:
N 2 = 6270 292 - 6.3978 ( 292 ) + 890,556 = 2,175,893 N
2
5) Calculate fs from the strain diagram when c = 356 mm.
490 - 365
fs = 700 = 240.0 MPa
365
s = t = f s Es = 0.0012
6) Substitute a = 284.8 mm and fs = 263.4 MPa in Eqn. 1 to calculate N1:
N1 = 5950 ( 292 ) + 963, 043 - 2174 ( 240.0 ) = 2,178, 683 N
Which is very close to the calculated N2 of 2,175,893 (less than 1% difference)
250
M = Ne = 2175 = 544 kN-m
1000
7) Check if compression steels yield. From strain diagram,
365 - 60
s' = ( 0.0035 ) = 0.0029 > y = 0.0023
365
Compression steels yields, as assumed.
8) Therefore, section capacity is
N = 2,174 kN
M = 544 kN-m
NTC 2008 Example 002 - 4