Combination of SNCR and SCR NOx Emission Control Systems
Combination of SNCR and SCR NOx Emission Control Systems
Combination of SNCR and SCR NOx Emission Control Systems
Robert E. Johnson
Karl Gebel
Werner Vale
Austrian Energy
Wagner Biro Str. 98 - 100
A-8021 Graz
Abstract:
Post-combustion NOx control technologies available to reduce emissions from fossil fueled
power plants include selective catalytic reduction (SCR) and selective noncatalytic reduction
(SNCR) systems. An additional post-combustion NOx emissions control strategy is the
hybrid combination of SNCR and SCR.
In 1987 OKA (Obersterreichische Kraftwerke AG) reduced the NOx emissions of its lignite-
fired Riedersbach Unit 2, Upper Austria, using air staging and flue gas recirculation by 50%.
In 1988 NOx emissions in this power plant were further reduced by 30% - 50% with a
combination of combustion modifications and SNCR technology, that is, a urea-water-
solution is injected into the boiler using overfire air or recirculated flue gas as carrier
medium. The overall NOx removal efficiency is 60% - 75% compared to 1987 levels.
Because of fuel switching from lignite to hard coal, an additional technology was necessary
to control the ammonia slip contaminating the FGD effluent. OKA decided to install
SCR-catalyst material within the boiler itself. The main purpose for this catalyst is to reduce
the ammonia slip coming from the SNCR system. In addition, to meet the ammonium
emissions limit in the FGD effluent, an improved NOx reduction efficiency is required.
As this approach to overall high efficiency and low-cost NOx control does not require space
for a stand-alone SCR reactor, it is an opportunity especially suited to those power plants
which have to be retrofitted under restricted space conditions.
The novelty of the SCR application is the arrangement of catalysts, so that the fly ash
laden flue gas passes the catalysts in an upward direction. It is the first application of its
type in the world.
Introduction
Equipping German hard-coal power plants with catalysts for nitrogen oxide reduction was
one of the most successful environmental protection measures of the last decade, reducing the
fraction of total emissions due to power plants to less than 10% [Fig. 1]. from pre 1985
levels. In Austria, NOx emissions were restricted in 1988 by the clean air act for plants as a
function of their thermal power output. Plants with 300 - 500 MW were restricted to 300
mg/mstp, and larger boilers to 200 mg/mstp.
In response to this, primary measures were taken to reduce the formation of nitrogen oxides
in the combustion process. With the exception of lignite combustion systems, it was not
possible to meet the strict limits with primary measures alone. The first secondary measures
to result for hard coal-fired boilers were full-scale SCR systems. In these systems, the
nitrogen oxides are transformed to water and nitrogen by selective catalytic reduction (SCR)
with ammonia over a catalyst surface.
At the time this technology was introduced in Europe about 10 years ago, there were still
uncertainties about the process and operational reliability of the SCR units and their effects
on overall power plant operation. Since then, the behavior of SCR catalysts has become well
known for various flue gas conditions and configurations. In the USA, plant manufacturers
and operators as well as catalyst manufacturers are in a similar situation to that prevailing in
Europe ten years ago. In the USA, as in Europe, test programs were first carried out to
determine whether European experience could simply be adopted or whether special plant
conditions required special solutions. For example, catalysts were installed in the flue gas
ducts of in-duct SCR plants. A DeNOx air preheater was also tested. Finally, a
combination of the various systems, known in the USA as hybrid SCR, has been constructed
and tested for nitrogen oxide reduction.
The test programs are now essentially complete. Operating experience gathered to date is
positive.
Five different plant concepts are included under the general heading of hybrid SCR:
Fig. 2 shows the installation locations for the various solutions in a simplified power plant
schematic. Not shown are the conventional configurations of a deNOx reactor between the
boiler outlet and air preheater (high-dust configuration) or between the electrostatic
precipitator and the stack (low-dust configuration). However, combinations of some Hybrid
SCR arrangements or all of these individual systems were not used in past years in Germany
or Austria. This is due to the high separation efficiency required to achieve the NOx
emissions limits. To date, legislation in the USA has not been oriented to the high efficiencies
proven to be attainable with conventional SCR technology.
The power plant operators in the USA are given more freedom to select a technology. This
opens the possibility for individual power plants to implement various measures such as the
hybrid systems listed above.
Of course the use of one or another variant must be justified by comparing its advantages
over classic SCR technology [Fig. 3].
Low retrofit requirements in existing power plants. For example, changes in the flue
gas ducting, air preheater relocation or the installation of a reinforced or new air fan
are not necessary.
Minimal impacts on unit draft loss, resulting in considerably lower operating costs.
Minimizationof ammonia slip with simultaneous and relatively high NOx removal
efficiencies.
Operating flexibility due to selective activation of DeNOx-subsystems as a function
of boiler load.
The Riedersbach 2 power plant, a 160 MW unit, was first designed for simultaneous firing of
lignite and hard coal or oil. The boiler schematic is shown in Fig. 4. The boiler is a two-pass
unit with dry ash removal and the heat exchanger surfaces are all located in the first pass.
Initially, typical NOx-emissions were 600 - 700 mg/mstp in this plant when fired with high-
ash austrian lignite (SAKOG).
The combustion temperatures in pulverized lignite firing systems are generally so low due to
the high ash content or the high water content in the coal that most of the nitrogen oxide
emissions are caused by the formation of fuel NOx. Operating experience with pulverized
lignite firings has shown that the level of the measured NOx emissions can be only slightly
reduced by lowering the combustion chamber temperature. Significant reductions in NOx
emissions cannot be achieved until the air ratio in the main burner area is reduced.
The engineering concept for NOx reduction in lignite firing systems can be implemented
through primary measures in different ways depending on the type of boiler construction.
However, all technical solutions will have the following common characteristics:
These measures have proven themselves on various designs of steam generators and in firing
of various lignites. The results of the staged air combustion are given qualitatively in the NOx
emissions as a function of stoichiometry in the burner area, shown in Fig. 5.
The combustion modifications of the firing system in the 160 MW Riedersbach 2 unit
performed by OKA over the years 1987 to 1989 to reduce NOx emissions are shown in
The use of all NOx-reducing primary measures in this boiler system enabled the achievement
of NOx emission levels of 300 - 350 mg/mstp. in simultaneous firing of 80% lignite and 20%
hard coal. This is a NOx reduction of approximately 50%.
It should be pointed out that the NOx emission levels of every power are subject to
considerable fluctuations, at least +/-10%, in spite of the best flue gas analysis, measuring
and control technology. Among other things, the causes for these fluctuations are:
Although NOx reduction by primary measures represents the cheapest and most widely used
technology, the delayed combustion process caused by the modifications can lead to the
following operating problems:
Additional measures were required at Riedersbach 2 to achieve the target half-hour averages
of 200 mg/mstp in lignite/hard coal simultaneous firing.
After combustion modifications, the most inexpensive technology for further NOx reduction
is found in SNCR processes. In the process developed by OKA, NOx is reduced by the
combination of combustion modifications and an SNCR technique for reducing NOx. This
method involves the indirect injection of a finely atomized urea/water solution into the
combustion chamber using overfire air or recirculated cold flue gas as carrier medium. Fig. 7
shows a process flow diagram of the SNCR test system in the Riedersbach 2 power plant,
planned in 1987, as well as the configuration of the cold gas and overfire air nozzles on the
boiler. The first overfire air level is not shown. The plant was improved repeatedly,
supplemented with equipment for producing urea solution from solid urea and modified to
form a DeNOx-system with the same availability as the boiler. Fig. 8 shows the configuration
of a urea lance in an overfire air branch line. A computer simulation was used to model and
optimize the mixing behavior of the urea droplets in the flue gas.
The following operating parameters were achieved with this plant in 1989:
Adherence to the NOx-concentration of 200 mg/mstp over the entire load range
(calculated as NO2 at 6% O2, half-hour average) in lignite/hard coal simultaneous
firing
NH3 / NOx stoichiometric ratio of 1.0 - 1.7 as a function of load
Control of ammonia slip upstream of air preheater as a function of load and
stoichiometric ratio to between 0.1 - 1.0 mg/mstp resulting in ammonia content of fly
ash: approx. 50 mg/kg
The ammonium content in the effluent of the downstream flue gas desulfurization
plant (FGD) varied between 4 and 10 mg/l in 4 - 7 m/h effluent.
Steam consumtion maintained at 1 -2 t/h
The total DeNOx efficiency of the primary measures and SNCR technology is 60 - 75% from
1986 levels. The DeNOx costs of this process developed by OKA are approx.
As a result of the unexpected closing of the brown coal supply mine, the simultaneous firing
system of the boiler had to be modified in the summer of 1994. It is now possible to achieve
100% load with hard coal, or 40% with lignite or oil. The combination of combustion
modifications and noncatalytic NOx reduction enables adherence to a NOx emission limit of
300 mg/mstp in operation with 100% hard coal.
The ammonia slip was changed noticeably by the slightly higher NOx formation rates in hard
coal operation and the massive reduction of ash content in the flue gas to less than 20% at
roughly constant urea dosing. The ammonia slip upstream of the air preheater increased from
0.1 - 1.0 mg/mstp to 1 - 6 mg/mstp. This level resulted in tolerable ammonia concentrations of
< 100 mg/kg in the fly ash. However, the ammonium emission limit of 10 mg/l in the FGD
effluent was exceeded.
OKA decided to control the SNCR ammonia slip with SCR catalytic reactors. The NOx
content of approx. 250 - 270 mg/mstp in the flue gas downstream of the SNCR and
upstream of the SCR now acts as a reactant.
Siemens plate-type catalysts with a pitch of 6.1 mm and a specific geometric surface area of
320 m2/m were installed, Fig. 9. Plate-type catalysts was selected because of the very
successful operational history in Germany. The catalyst elements are combined in modules of
eight each in two superimposed levels. The modules, with dimensions of 956 x 956 x 2000
mm are designed for three-layer charging, thus providing space for later reloading.
The boiler area immediately upstream of the transverse section was selected for installation
[Fig. 10]. The inlet velocity is approx. 6.5 m/s at temperatures of 300 - 330 C. A support
grid for the 80 catalyst modules was installed there [Fig. 11]. The flue gases passes the
catalyst plates from bottom to top. This is a first for a high-dust configuration of this type.
The catalytic reactor has been in successful operation for 5000 hours. The ammonia slip
downstream of the catalytic reactor is so low that it cannot be reliably measured in the flue
gas, while the ammonia entrainment in the FGD effluent has decreased to 4 - 6 mg/l. The
ammonium emission limit of 10 mg/l can be adhered to reliably. Clogging or erosion of the
catalyst has not been observed to date. For safety reasons, a permanent steam sootblowing
system was installed below the catalyst on the upstream side of the catalytic reactor . These
steam soot blowers are operated once weekly with superheated steam at a pressure of 4 bar.
An increase in pressure drop across the catalytic reactor has not been observed. For reasons
of availability, it was not tested whether periodical sootblowing is actually required.
In summary, it can be stated that retrofit hybrid SCR units may offer advantages over
conventional SCR units for certain units, considering required NOx reduction and existing
plant conditions. In various plants it has been demonstrated that SIEMENS catalysts are
reliable tools to build up high performance hybrid systems as well as conventional full-scale
SCR units.