This document provides a block diagram and description of the circuit operation for an MK5PFC-II Power Supply. The power supply takes in AC mains input which is then filtered and sent to a power factor correction converter. A primary housekeeping controller monitors the mains input and output feedback to control startup, shutdown, and output regulation. An isolated DC/DC converter provides multiple isolated and regulated DC outputs while monitoring output voltage, current, and faults. Safety isolation is provided between primary and secondary circuits.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
553 views1 page
MK5PFC-II Functional Block Diagram
This document provides a block diagram and description of the circuit operation for an MK5PFC-II Power Supply. The power supply takes in AC mains input which is then filtered and sent to a power factor correction converter. A primary housekeeping controller monitors the mains input and output feedback to control startup, shutdown, and output regulation. An isolated DC/DC converter provides multiple isolated and regulated DC outputs while monitoring output voltage, current, and faults. Safety isolation is provided between primary and secondary circuits.
Mains Housekeeping Monitoring Monitor Control Control and Control Output
Low Isolation Power AC Signal
Description of circuit operation
1. AC Mains Input : AC supply source, nominally 110Vac to 240Vac. 2. Input Mains Filtering : Provides current inrush surge limiting at power up, EMI filtering between the mains input supply and high frquency switching components inside the converter and protection against mains supply overvoltage surges. 3. Switched Mains Control : Isolated control circuitry for switching mains supply on and off to the AC monitor output. 4. AC Monitor Output : Electronically switched mains output supply. 5. Low Power AC Signal : Isolated input signal for controlling the AC monitor supply. 6. PFC : Power factor correction converter for achieving near unity power factor loading on the mains supply input. 7. Primary Housekeeping Control : Monitors the mains input voltage and output feedback signals to control startup, shutdown and output regulation of the main converters. 8. Isolated DC/DC Converter : DC to DC power conversion stage incorporating safety isolation between the mains input and DC output supplies. Provides fault protected multiple output rails for the main load and auxilliary loads. 9. Output Monitoring and Control : Monitors overvoltage, undervoltage, current limit and output voltage regulation and feeds back the information to the primary control circuits for the control of shutdown and voltage regulation. 10. Isolation : Provides for safety isolation of the feedback control signals between primary and secondary circuits. 11. DC Outputs : Fully protected and regulated DC output supply for powering the load as required.