Motor Rating Start kVA Maximum Starting kVA / Amps

This document provides a chart listing electric motor ratings from 1 to 280 kW along with the maximum starting kVA and amps for direct online (DOL) and star-delta starting methods. The chart is intended as a guideline for sizing three phase electric motors and determining starting requirements, but is not a substitute for having a qualified electrician perform an on-site load test.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
119 views1 page

Motor Rating Start kVA Maximum Starting kVA / Amps

This document provides a chart listing electric motor ratings from 1 to 280 kW along with the maximum starting kVA and amps for direct online (DOL) and star-delta starting methods. The chart is intended as a guideline for sizing three phase electric motors and determining starting requirements, but is not a substitute for having a qualified electrician perform an on-site load test.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

THREE PHASE ELECTRIC

MOTOR CONVERSION

Motor
Start kVA
Rating Maximum Starting kVA / Amps
kW HP Rated kW Direct Online (kVA) DOL (Amps) Star-Delta (kVA) Star-Delta (Amps)
1 1.34 10.5 10.5 15.16 3.50 5.06
1.5 2.01 10.5 15.75 22.74 6.25 9.03
2 2.68 10.5 21 30.32 7.00 10.11
3 4.02 9.8 29.4 42.44 9.80 14.15
4 5.36 9.8 39.2 56.59 13.10 18.91
5 6.7 9.8 49 70.73 16.30 23.53
7.5 10.1 9.2 69 99.6 23.00 33.2
10 13.4 9.2 92 132.8 30.70 44.32
15 20.1 9.2 138 199.2 46.00 66.4
20 26.8 8.7 174 251.16 58.00 83.72
25 33.5 8.7 217.5 313.95 72.70 104.94
30 40.2 8.7 261 376.74 87 125.58
35 48.9 8.7 304.5 439.53 102 147.23
40 53.6 8.7 348 502.31 116 167.44
45 60.3 8.2 369 532.63 123 177.55
50 67 8.2 410 591.81 137 197.75
55 73.7 8.2 451 650.99 150 216.52
60 80.4 8.2 492 710.17 164 236.73
65 87.1 8.2 533 769.35 178 256.93
70 93.8 8.2 574 828.53 191 275.7
75 101 8.2 615 887.71 205 295.91
80 107 8.2 656 946.89 219 316.11
85 114 8.2 697 1006.07 232 334.88
90 121 8.2 738 1065.25 246 355.09
95 127 8.2 779 1124.43 260 375.29
100 134 8.2 820 1183.61 273 394.06
108 142 7.8 842.4 1215.94 276 398.39
112 150 7.8 873.6 1260.97 291 420.04
118 158 7.8 920.4 1328.53 307 443.13
125 168 7.8 975 1407.34 325 469.12
132 177 7.8 1029.6 1486.15 343 495.1
140 188 7.8 1092 1576.22 364 525.41
150 201 7.8 1170 1688.8 390 562.94
160 214 7.8 1248 1801.39 416 600.47
170 228 7.8 1326 1913.98 442 638
180 241 7.8 1404 2026.56 468 675.52
190 265 7.8 1482 2139.15 494 713.05
200 268 7.8 1560 2251.74 520 750.58
212 284 7.8 1653.6 2386.84 551 795.33
224 300 7.8 1747.2 2521.94 582 840.07
236 316 7.8 1840.8 2657.05 614 886.26
250 336 7.8 1950 2814.67 650 938.23
265 355 7.8 2067 2983.55 671 968.54
280 376 7.6 2128 3071.6 709 1023.39

This chart is intended as a guideline and not a substitute for having a load test performed by a
qualified electrician.

2 Bravo Road, Jet Park, Johannesburg www.AbsolutePowerAfrica.co.za


T +27 (0) 11 397 7373 F +27 (0) 11 397 7404