Industrial Computing - PLCs
Industrial Computing - PLCs
Industrial Computing - PLCs
AS-i 877
Fieldbus 874
PLC187
LOGO! Contact
Enables loads up to 20A and motors up to
44W to be switched directly
24Vdc or 230Vac switching voltages available
Useful for noise-sensitive areas such as hospi-
tals or domestic environments
Price Each
Voltage Mftrs. List No. Order Code 1+ 5+ 10+ 25+ Ideal for the new user, the starterbox contains everything you need to get started using
LOGO! for the first time
24Vdc 6EDI 057-4CAOO-OAAO 309-6490 51.00 49.11 47.37 46.05
230Vac 6EDI 057-4EAOO-OAAO 309-6506 42.00 40.44 39.00 37.92 Low cost option for getting started
Comes in an attractive toolbox style case
Starterbox contains: LOGO! Short, 115/230Vac LOGO! Manual
PC programming cable Tips and Tricks CD-ROMl
LOGO! Soft
854 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
PLC197
Mitsubishi PLCs
Price Each
Order Code 1+ 5+ 10+ FXON-Micro
Base Units
LOGO! Starterbox 309-6488
Intelligent Relays
Easy
Intelligent - all-round product for
switching and control
Uses keystrokes to make classic wiring
diagrams
Clear function layout
20 standard functions conbined in one
unit Incorporates all the powerful features of the FXO, with expansion capability
Menu driven Programming can be achieved by using GPP/WIN software (329-9963) and Hand-
Password function to enable selective held programmer (276-315)
access Standard Features include: I/O bus connection for extending upto
Five language menu: English, French, High speed, 3.6s per logic instruction 128 I/O
Dimensions German, Italian and Spanish 2000 step EEPROM memory Advance Features include:
71.5 90 53
Built-in RUN/STOP switch 4 built-in combined 5kHz high speed
Functions Include 2 built-in analogue adjustment poten- counters (configurable 2 off AB phase
8 timers, each 0 to 100hrs, (each is multifunction) tiometers bi-direction)
4 Real Time clocks (on RC versions) Built-in 24Vdc supply (200mA) Analogue extension capability
8 up/down counters 64 timers (100ms, 10ms, 1ms unit RS232C user-defined communications
8 Inputs/4 outputs (2 inputs can be used as analogue on DC versions) versions) interface option
8 impulse relays 48 standard counters (latched, Real-time clock cassette option
8 Comparators unlatched) Scan independent high speed outputs
16 Internal relays 256 data registers (further 128 latched) Step ladder sequence for data table
32 bit arithmetic (10 digit numbers) manipulation
EASY 412-AC-R 115-230V AC
EASY412-AC-RC 115-230V AC with Real Time Clock
EASY 412-DC-R 24V DC Supply voltage 100 to 200Vac +10% - 15% or 24Vdc +10% - 15%
EASY 412-DC-RC 24V DC with Real Time Clock Supply for sensors 24Vdc, 100mA (ac version only)
EASYSOFT (Software) Software Package Inputs 24Vdc, 7mA opto-isolated (sink/source configurable)
EASY PC CABLE (2M) 2M cable for connection to PC Outputs Volt free relays, rated 2A@250Vac or 30Vdc
CTL338
External Dimensions
Price Each Description H W D Mftrs. List No. Order Code
Mftrs List No. Order Code 1+ 5+ 10+ 14 in, 10 out, ac powered 90 135 87 FXON-24MR-ES 774-420
24 in, 16 out, ac powered 90 150 87 FXON-40MR-ES 774-431
EASY 412-AC-R 222-203 36 in, 24 out, ac powered 90 185 87 FXON-60MR-ES 774-443
EASY 412-AC-RC 222-215 16 in, 8 out, dc powered 90 135 87 FXON-24MR-DS 774-455
EASY 412-DC-R
EASY 412-DC-RC
EASYSOFT (Software)
222-185
222-197
222-227
24 in, 16 out, dc powered
36 in, 24 out, dc powered
90
90
150
185
87
87
FXON-40MR-DS
FXON-60MR-DS
774-467
774-479 26
EASY PC CABLE (2M) 222-240
FOR SUITABLE PROGRAMMER SEE ORDER CODE 329-8863 PAGE 860
continued
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 855
Industrial Computing & PLC's
Mitsubishi PLCs continued Real-Time Clock Cassette
Extension Blocks
Can be 774-558
added to base unit or extension unit to
increase capacity
Supply voltage 24Vdc +10% - 15%
774-546
Input Output External Dimensions Order Code Mftrs. Order Price Each
8 sink/source H=90, W=43, D=87 774-492
8 relay H=90, W=43, D=87 774-509
List No. Code 1+ 2+ 5+ 10+ 20+
8 transistor H=90, W=43, D=87 774-510 Real-Time
PLC140X
Clock Cassettes FX-RTC 774-546
Price Each Real-Time
Mftrs. List No. Order Code 1+ 2+ 5+ 10+ 20+ Clock Battery FXON-40B 774-558
FXON-8EX-ES 774-492
FXON-8EYR-ES 774-509
FXON-8EYT-ESS 774-510 The FX Family of Programmable Controllers
The FX Family of Programmable Controllers.
The FX Family of Programmable Controllers offer the user a wide range of applications
Analogue to Digital Converters from small low cost relay replacement, to sophisticated control of up to 256 I/O. The
Special Block family utilises common peripheral devices such as programmers, man machine inter-
faces (MMIs) and memory cassettes.
Has two input channels and one output Programming of the FX family is performed using either the MELSEC MEDOC menu
channel driven ladder/logic instruction set software package, or using one of the two hand held
Input channels receive an analogue sig- programmers available (FX-20P-E & FX-10P-E).
nal and convert it to a digital one
Output channel takes a digital valve and FXO
outputs on equivalent analogue signal Micro compact size
Stand alone programmable controller includes built in power supply, CPU and
Key Features: switch gear
Default Input/Output ranges 0-10Vdc Easy to configure and use
26 Current selection via terminal wiring
Offset and gain adjustable to give 0-5V,
Available in 3 different I/O sizes, 14, 20 & 30
High processing speed (3.5 s/basic instructions)
4-20mA 800 step battery free memory using an internal EEPROM
8 bit resolution
FXON
Industrial Computing & PLC's 856
Price Each
Mftrs. List No. Order Code 1+ 2+ 5+ 10+ 20+
FXON-232A DP 774-534
856 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Fast execution of basic instruction set ( 0.47s) Powered Extension Units - Digital
Floating point maths for better handling of decimal numbers I/O
PID control loop for precise and responsive control
6 high-speed counters up to 10KHz maximum
Built-in 2000 step program memory expandable to 8000 steps using additional
memory cassettes
FX units include a wide tolerance ac power supply which will operate within the
voltage range 85V ac to 264V ac
Wide range of additional I/O modules and special function modules available
Relay outputs can be used for both ac and dc applications
Standard programming functions include PID and floating point maths
The FX range of programmable controllers can be combined with a range of expansion
blocks and powered extension units, making them suitable for large and small
applications. The FX family of controllers are available with main processing units 24V dc service supply provided on each unit
ranging from 16 to 128 I/O points, all of which can be expanded up to a total of 256 Removable terminal blocks for ease of installation and maintenance
points I/O. Communications add on modules allow connection to modems, printers, Flexible installation position: adjacent or parallel installation using cables provided
bar code readers, thermocouples, analogue devices, etc. Optional DIN rail or direct mounting
Wide range ac power supply will accept 85 to 264V ac at 50 to 60Hz
The FX can be programmed in stepladder (STL) using either a computer-based soft-
ware, GPP/WIN or hand-held programmer, the FX-20P-E. The FX main processing unit can be expanded with additional I/O up to 256 points.
Small increases in I/O capacity are achieved using unpowered expansion blocks; how-
Total I/O O/P I/P Unit Size Weight Mftrs List No. Order Code ever, large scale increases in I/O require the FX range of powered extension units.
16 8 8 150 x 140 x 95 1.0 kg FX-16MR-ES 711-4552 Additional benefits of the powered extension units include the facility to add special
24 12 12 150 x 140 x 95 1.3 kg FX-24MR-ES 711-4564
32 16 16 160 x 140 x 95 1.5 kg FX-32MR-ES 711-4576
function blocks i.e. analogue and the use of an additional 24V dc service supply. The
48 24 24 230 x 140 x 95 2.0 kg FX-48MR-ES 711-4588 powered extension unit is connected to the FX main processing unit using either the
64 32 32 270 x 140 x 95 2.5 kg FX-64MR-ES 711-4590 55mm or 650mm cable supplied. This allows mounting of the powered extension unit
80 40 40 330 x 140 x 95 3.0 kg FX-80MR-ES 711-4606 adjacent to the FX main processing unit or in parallel.
128 64 64 410 x 140 x 95 4.0 kg FX-128MR-ES 711-4618
The I/O allocation on each unit is divided equally between Inputs and Outputs (I/O).
inc67 The input devices operate at 24V dc and can be configured to accept either Sink (NPN)
or Source (PNP) style wiring. The relay outputs provide users with the flexibility to
Price Each switch ac or dc outputs as required.
Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+
FX-16MR-ES 711-4552 Total I/O Unit Size Weight Mftrs List No. Order Code
FX-24MR-ES 711-4564 32 160 x 140 x 95 1.5 kg FX-32ER-ES 711-4837
48 230 x 140 x 95 2.0 kg FX-48ER-ES 711-4849
FX-32MR-ES 711-4576 inc71
FX-48MR-ES 711-4588
FX-54MR-ES 711-4590 Price Each
FX-80MR-ES 711-4606 Mftrs. List No. Order Code 1+ 2+ 5+ 10+ 20+
FX-128MR-ES 711-4618 FX-32ER-ES 711-4837
FX-48ER-ES 711-4849
Price Each
Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+
FX-485PC-IF 713-5610
FX-485ADP 713-5592
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 857
Industrial Computing & PLC's
Mitsubishi PLCs continued Active Communications Adaptor -
RS232
Parallel Link Adaptor Enables the FX to produce its own data files and reports,
Allows two FX Main Processing Units to be i.e. production quotas or maintenance points, directly onto
linked to provide a basic synchronisation a printer
between their individual programmes Facilitates connection to a wide range of data gathering
Can exchange 10 data words and 100 bit devices, i.e. bar code readers, tagging systems, etc
devices in each communication direction, Allows the FX to be used as a remote station, using a
i.e. the total system processes 200 bit modem to call in with status data and breakdown reports
devices and 20 data registers Communications can be initiated by the FX or from a central
Requires minimal set-up to achieve computer carrying out maintenance checks
immediate communication and simple use
of the PRUN Applied Instruction
All power requirements are serviced
through the bus connection to the FX Main
Processing Unit
Transmission medium: twisted pair (wire),
not included. Shielded cable should be
used for greatest EMC protection The FX-232ADP connects to the left-hand port of an FX main processing unit and
Transmission distance: 10 metres allows communication with a wide range of industrial RS232 compatible products,
One FX2-40AW unit required for each Main Processing Unit (MPU), therefore two including bar code readers, printers, computers and modems, etc. Control of the com-
units required for a system munications protocol uses a single applied instruction available in every version 3.3
(or greater) FX main processing unit.
The FX2-40 AW parallel link adaptor makes it possible to synchronise or co-ordinate
two operational machines, without using a full network solution. A typical application Modem control with the FX-232ADP is enhanced with an automatic carrier detect fea-
would be a conveyor where the controllers are working with common equipment. ture, allowing detection of telephone line connection.
Common control can be achieved by connecting one FX2-40AW to the left-hand port of Size Weight Mftrs List No. Order Code
each FX main processing unit and linking the two with a twisted pair cable. One main 25 x 140 x 45 0.2 kg FX-232ADP 711-5970
processing unit is then designated as the master unit, the other as slave to complete
inc79
the system set-up. 10 data registers and 100 bit devices can be exchanged in each
direction between the master and slave controllers. Price Each
Size mm Weight Mftrs List No. Order Code Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+
45 x 140 x 95 0.3 kg FX2-40AW 711-5891 FX-232ADP 711-5970
inc78
Price Each
Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+ Analogue Input & Analogue Output
FX2-40AW 711-5891
Price Each
Order Code 1+ 5+ 10+
Price Each
Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+
FX-232AW 711-6100
Major International
Brands
All the leading brand names from over
1,000 major international manufacturers.
858 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Temperatuire Sensing Inputs Pulse Train Output Block
Platinum Resistance PT100 & J & K
Maximum 100kpps output train
The FX-2AD-PT is equipped with 12 bit conver- Seven built-in operating modes
sion providing the FX Main Processing Units Operates with 32 bit accuracy and
(MPUs) with a digital temperature reading in the allows multiplication factors of 100, 101,
range of -100C to +600C. The control and 102 and 103 when used for positioning
operation of the FX-2AD-PT is accessed by the data
FX applied instructions TO and FROM. The use Four command units as standard:
of the FX-2AD-PT can be enhanced by combin- pulse, micro-metres, mdeg and 10-4
ing it with analogue-to- digital and digital-to- inches
analogue devices, such as the FX-4AD and FX- One FX-1PG-E controls a single inde-
2DA. Applications of a combined system include pendent axis. However, up to 8 special
control of office, house, factory environments, function blocks can be connected to an
etc, where analogue operational limits could be FX system
controlled from a rheostat/potentiometer and For a closed loop system, use with the
digital inputs using a thumbwheel/keypad. high speed counters of the FX base
units
The FX-1PG-E single axis positioning control module has 100kpps (kilo-pulses per
Features include: second!) digital output. Extra inputs directly on the unit allows connection of switches
Temperature readings can be made in Centigrade or Fahrenheit which may require a speedy response. The FX main processing unit controls the oper-
2 input channels for the PT100 (3 wire) thermocouples ation of the FX-1PG-E through the use of the TO and FROM applied instructions.
Resolution: 0.2C
Accuracy: 1% F.S. (of the compensated temperature range) It is possible to control more than one independent axis through the connection of
additional FX-1PG-E units to the FX system. Typical FX-1PG-E applications include X-Y
The FX-4AD-TC, thermocouple sensor module has 4 channels which can be indepen- table control and motor speed control.
dently configured to read either K or J type thermocouples. The FX-4AD-TC requires no
complicated programming and is controlled using the standard TO and FROM applied Size Weight MftrsList No. Order Code
45 x 140 x 95 0.3kg FX-1PGE 711-5805
instructions of the FX. Typical applications include controlling muffle furnaces, small inc76
ovens, molten plastic temperatures or even die temperatures when extruding alumini-
um. The active temperature ranges are dictated by the type of thermocouple used: K- Price Each
type device can operate between -100C to +1200C & J-type thermocouples can oper- Mftrs. List No. Order Code 1+ 2+ 5+ 10+ 20+
ate between -100C and +600C. FX-1PG-E 711-5805
Features include:
Four independently configurable channels for use with K- or J- type thermocouples
12 bit analogue data values Memory Cassettes
Access to Centigrade and Fahrenheit data immediately without having to econfigure Small and durable construction, ideal forsending out program updates
the unit The Real Time Clock (RTC) Cassette and the FX-EEPROM-4C have automatic leap
Resolution: K-type thermocouples 0.4C, J-type thermocouples 0.3C year compensation until the year 2079. RTC features can be used to increase eco-
Accuracy: 0.5% F.S. + 1C nomic operation
Size Weight Mftrs List No. Order Code All EEPROM and RTC cassettes and can be used with FXON For battery backup of
73 x 140 x 95 0.5 kg FX-2AD-PT 711-5271 real-time clock data, use FXON-40B
73 x 140 x 95 0.5 kg FX-4AD-TC 711-5428
inc73
All EEPROM and RAM cassettes can be used with FX series controllers, battery
backup is provided as standard
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 859
Industrial Computing & PLC's
Mitsubishi PLCs continued
The FX2N can be described as having advanced control features normally associated
Programmers and Data Access Units with PLC rack based products but housed in the body casing of a Micro PLC. As with
FX-20P-E Hand-Held Programmer all Mitsubishi PLCs the use and application of FX2N products provide simple solutions
as sophisticated problems.
The FX-20P-E hand-held programmer can be used with
FX2N range of PLCs can use all the Extension units, Expansion blocks and Special
FX0, FX0N and FX main processing units. The FX-20P-E
function blocks of the Micro FXON range in addition to its own FX2N dedicated units.
has a bright back-lit LCD screen with 4 lines of 16 charac-
This means the users can grow the control unit to suit the changing requirements of
ters displayed at any one time. Additional functions
the required tasks over time.
include forcing program elements ON or OFF and dynamic
All units Base Units have an onboard 24V dc power supply for input devices etc.
stepladder monitoring, useful during commissioning and
fault-finding. Powerful and easy to perform applied instructions
Features Include: Processing speed 80 nanoseconds (0.8microseconds) per basic instruction
Has a bright 4 line display providing ease of use in 8K step programme capacity built in, expandable to 16K steps with optional cas-
dark environments settes
Can store an 8000 step program within its own mem- Built in Real Time Clock and Calender (Y2K compliant - valid through 1980 to
ory for up to 3 days due to capacitive backup 2079)
An additional adapter cable (FX-20P-CADP) is Built in High Speed Counters, up to 60KH single phase, 30KHz 2 phase
required for connection to FX0 and FX0N main pro- 8000 Data registers (16 bit), 3072 internal flags
FX-20P-E
cessing units Pulse train output up to 20KHz
INC95 Base units may be configured with FX2N and FXON extension units and extension
blocks up to 256 I/O
Price Each Multiple communication and networking options - up to 9 RS232 ports can be
Mftrs. List No. Order Code 1+ 5+ 10+ added to FX2N base units. Other options include 485 multidrop, 1:N. N:N commu-
FX-20P-E 714-8999 nication methods etc.
FX-20P-CADP 276-352 LED status indication
Password security
Din rail or direct mounting options
Connecting Cables Applied instruction sets include: Program flow, data manipulation and comparison,
arithmetical and logical instruction including floating point, Square Root, SIN, COS and
276-388 (SCO7) Protocol Converter
instructions for inputs ad outputs. Communication instructions such as ASCII and
A cable and protocol converter in one. One end of the cable plugs into the PLC and the
HEX conversions, Sum checking instructions.
other end is terminated with a 9 pin D sub-connector.
Programming features include: on-line/off-line programming, on-line monitoring and
276-352 (FX-20P-CADP) Adaptor Cable For FXO/FXON testing. Remote Run/Stop control (users could use this feature to program/monitor
A 0.3m long cable adaptor which allows a 25 pin D sub-male connector to be plugged /control remotely over a modem) Advanced diagnostics and built in error checking in
into an FXO/FXON PLC. each FX2N PLC 3 levels of security via a password entry code system built in as stan-
720-6872 FX-20P-CAB Connection Cable for FX dard.
A 1.5m long cable which can be used with either an FX-20P-E(714-8999), FX-10DU-E Programming: via hand held programmer FARNELL stock no. 714-8999 or using a new
(276-376) or an FX-10P-E (276-315) to provide the communication link to an FX low cost but highly efficient and effective WIndows Y based programming package
Programmable Controller. Note: This cable is already supplied with the FX-20P-E. FARNELL stock nos. 725-8410
inc131 Note: As a quick check, the following notes should be used. Please note that the FX2N units can far
exceed the values quoted below, but the full congifuration rules need to be observed.
Price Each Base units up to 32 I/O can accept extra extension blocks up to 24 I/O
26 Order Code 1+ 5+ 10+ Base units from 48 I/O can accept extra extension blocks up to 48 I/O
Protocol converter 276-388
Adaptor cables 276-352 FX2N Base Units
Cable FX 720-6872
Industrial Computing & PLC's 860
GPP/WIN Software
GPP/WIN is a powerful Windows based programming tool for the full range of
Mitsubishi controllers.
Switch between instruction list and ladder diagram format
Access to all PLC parameters, network configurations and comment tables
Project navigator to provide clear overview of the entire project
Ability to use existing programs written using MELSEC MEDOC, FX-PCS-WIN,
GPPA and GPPQ
Program components can be copied between projects for reuse Inputs are configurable as being Sink or Source (NPN or PNP).
Windows 95, 98 and NT Wide power supply tolerance, 100 to 240V +10%/-15% 50/60Hz
inc263
24V DC service/sensor supply built in
Price Each Volt free relay isolated outputs can be used with up to 240V a.c. or 30V d.c.
Mftrs. List No. Order Code 1+ 5+ 10+ switching.
Inputs are opto isolated 24V d.c.
GPP/WIN 329-8863 Opto isolated Source (PNP) transistor outputs can be used signals from 5 to
30V dc inc205
860 Electronic, Electrical and Mechanical Prices are in Hong Kong Dollars
Farnell June 2001 Book 1 CYAN MAGENTA YELLOW BLACK Page 860 HONG KONG CATALOGUE
Industrial Computing & PLC's
Extension Blocks High Speed Counter
These blocks increase the capability or capacity when added to any powered base or This unit provides an independent high speed counter input to an FX2N system. The
extension unit. Extension blocks need only the signal lines and no other power source unit is controlled using TO/FROM instructions. There are hardware outputs which can
to operate. be triggered by an internal counter comparison feature to get very high speed respons-
INC206 es.
Price Each Note: For configuration purposes each this unit is considered as occupying 8 I/O
Mftrs. List No. Order Code 1+ 2+ 5+ 10+ points an FX2N system.
Unpowered Extension Blocks
Inputs
16 I/P FX2N16EX-ES/UL 725-8161
Inputs can be single or 2 phase up to 50kHz
16 O/P trans FX2N16EY-ESS/UL 725-8173
Single phase counters can be configured with 1 or 2 inputs
16 O/P relay FX2N16YR-ES/UL 725-8185
Two phase counters can be configured with 1, 2 or 4 edge counting profiles
Powered Extension Blocks Input Signals of 5V, 12V and 24V (Sink or Source) are accepted
16 I/P, 16 and 32 bit counter ranges are available
16 O/P Relay FX2N32ER-ES/UL 725-8197
Outputs
24 I/P,
12 to 24 V d.c. (0.3A max) sources can be controlled
24 O/P Relay FX2N48ER-ES/UL 725-8203
Optional outputs offer Sink or Source switching
24 I/P,
Hardwired outputs can automatically be triggered after the counter has reached
24 O/P Relay FX2N48ET-ESS/UL 725-8215
user defined predetermined values/limits
INC219
Internet www.farnell.com Sales Tel 8104 8208 Sales Fax 8104 8268 861
Farnell June 2001 Book 1 CYAN MAGENTA YELLOW BLACK Page 861 HONG KONG CATALOGUE
Industrial Computing & PLC's
Mitsubishi PLCs continued S7-221 CPUs
10 I/O non expandable (6 in, 4 out)
Communications Boards 2 Kbytes programming memory
4 x 20kHz high speed counter
The FX2N base units have the flexibility to be enhanced with additional communication
Real time clock option
boards. These are added directly to the base unit itself. The available units are:
24V d.c. input
FX2N-232-BD INC261
This board provides RS232 communication with an suitable RS232 device, i.e, person-
al computers, printers, bar code readers and modems. Order Price Each
FX2N-422-BD Supply Output Mftrs. List No. Code 1+ 5+ 10+
The FX2N-422-BD is essentially a second programming port for the FX2N base unit. It 24V d.c. 24V d.c. 6ES7 211-1AA20 0XB0 313-9750
is also possible to interface any of the Mitsubishi range of HMIs through this port, this 120/230V a.c. Relay 6ES7 212-0BA20 0XB0 313-9761
would then make it possible to have two HMI units connected to a single PLC as a
standard solution.
FX2N-485-BD S7-222 CPUs
This is the RS485 board unit to attach the FX2N base unit on to a 1:N data collection
14 I/O expandable (8 in, 6 out)
network, or as a note on a multi-drop network (N:N)
2 Kbytes programming memory
FX2N-CNV-BD 4 x 20kHz high speed counter
This converter board allows the FX2N to use the FX0N range of ADP communication Real time clock option
adapters, i.e. FX0N-232ADP, FARNELL stock no.774-534. Using the FX0N communica- 24V d.c. input
tion adapters provides optoisolated communications options as well as the ability to INC267
communicate over long distances.
Note: Only one BD board may be fitted to each FX2N PLC at any one time. Application Order Price Each
boards; FX2N-232-BD, FX2N-422-BD, FX2N-484-BD, FX2N-CNV-BD, FX2N-8AV-BD. Supply Output Mftrs. List No. Code 1+ 5+ 10+
24V d.c. 24V d.c. 6ES7 212-1AB20-0XB0 313-9773
INC223
120/230V a.c. Relay 6ES7 212-1BB20-0XB0 313-9785
Price Each
Mftrs. List No. Order Code 1+ 2+ 5+ 10+
FX2N-232-BD 725-8306 S7-222 CPUs
FX2N-42-BD 725-8318 24 I/O expandable (14 in, 10 out)
FX2N-485-BD 725-8320 28 Kbytes programming memory
FX2N-CNV-BD 725-8288 6 x 20kHz high speed counter
In-built real time clock
24V d.c. input
Windows Programming Package. INC268
Windows based programming for the FX PLC Family Order Price Each
FXO, FXOS, FXON, FX, FXN2 (FX-PCS/WIN-E)
Supply Output Mftrs. List No. Code 1+ 5+ 10+
The latest in a successful range of PC based programming tools, FX-PCS/WIN offers 24V d.c. 24V d.c. 6ES7 214-1AB20-0XB0 313-9797
the user the ease and benefit of the Windows operating system along with 3 powerful 120/230V a.c. Relay 6ES7 214-1BB20-0XB0 313-9803
PLC programming editors, documentation, monitoring and testing facilities, FX-
PCS/WIN also offers the ability to import print files product for the DOS MEDOC pro-
26 gramming package.
INC208
Digital Expansion Modules
These are used to increase the capacity of the
Price Each S7-200 CPUs. A maximum of 2 modules can be used with the S7-222, up to 78 I/O. A
Mftrs. list No. Order Code 1+ 2+ 5+ 10+ 25+
Industrial Computing & PLC's 862
maximum of 7 modules can be used with the S7-224, up to 128 I/O. Connection is via
FX-PCS/WIN-E 725-8410 ribbon cable (supplied).
Specifications:
Inputs 24Vdc rated, sink/source, opto-isolated
Cable Relay Outputs Volt free 2A; 5-30 Vdc or 5-250Vac
Transistor Outputs 20.4-28.8 Vdc, 0.75A
Used for multi-drop connection to a master computer or data transfer with FX2N INC262
units
All cables 1m in length Order Price Each
inc231
Input Output Mftrs. List No. Code 1+ 5+ 10+
Price Each 4 4 transistor 6ES7 223-1BF20-0XA0 328-9941
Description Mftrs. List No. Order Code 1+ 2+ 5+ 10+ 4 4 relay 6ES7 223-1HF20-0XA0 328-9953
RS232 Comms FX-232-CAB-1 725-8367 8 - 6ES7 221-1BF20-0XA0 313-9815
RS422 Comms FX-422CAB 725-8379 - 8 transistor 6ES7 222-1BF20-0XA0 313-9827
RS485 Comms FX-422CAB0 725-8380 - 8 relay 6ES7 222-1HF20-0XA0 313-9839
RS232-422 8 8 transistor 6ES7 223-1BH21-0XA0 313-9840
Converter FX-232AWC 725-8392 8 8 relay 6ES7 223-1PH21-0XA0 313-9852
16 16 transistor 6ES7 223-1BL21-0XA0 328-9965
16 16 relay 6ES7 223-1PL21-0XA0 328-9977
Siemens PLCs
Simatic S7-200 Micro PLC Analogue Expansion Modules
The 2nd generation S7-200 offers small but powerful CPUs with flexible I/O that can be Provide analogue capability for the 222 and 224 CPUs
tailored to suit simple or complex automation tasks, giving the best optimised and low- Inputs are selectable via dip switches, variable outputs by connection
est-cost solutions. Easy-to-use, Windows based software unlocks the powerful, in- Inputs 12 bit resolution
built computing and communications features. The enhanced expansion modules allow Outputs 12 bit resolution (voltage), 11 bit resolution (current)
more flexible solutions which, coupled with the upgraded software, mean changing Module Type Configurations
from other solutions is easier than ever. 4 Input unipolar - 0 to 5V, 0 to 10V or 0 to 20mA
All models feature: bipolar - +/- 2.5V or +/- 5V
High speed 0.37s per instruction In-built power supply 2 Output +/- 10V, 0 to 20mA
4 Input / 1 Output Inputs: Unipolar 0 to 50mV, 0 to 100mV, 0 to 500mV, 0 to 1V, 0 to 5V, 0 to
2 x 20kHz pulse outputs PID instructions 10V, 0 to 20mA
1 x RS485 communications interface Bipolar - +/-25mV, +/-50mV, +/-100mV, +/-250mV, +/-500mV, +/-1V,
Specifications: +/-2.5V, +/-5V
Supply voltage 85-264Vac, 47/63Hz or 20.4-28.8Vdc Outputs: +/- 10V, 0 to 20mA
Supply for sensors 24Vdc, 180mA(221 & 222 CPU) or280mA(224 CPU) INC260
Inputs 24Vdc, 7mA opto-isolated (sink/source configurable)
Relay outputs Volt free 2A; 5-30Vdc or 5-250Vac Price Each
Transistor outputs 24Vdc,0.75A Input Output Mftrs. List No. Order Code 1+ 5+ 10+
INC257
4 - 6ES7 231-0HC20-0XA0 315-4348
- 2 6ES7 232-0HB20-0XA0 328-9990
4 1 6ES7 235-0HD20-0XA0 315-4350
862 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
AS-i Master Module Simatic S7-200 Micro PLC
Module used as an AS-i master on an AS-i network The 2nd generation S7-200 offers small but powerful CPUs with flexible I/O that can be
One AS-i master can be used with the S7-222CPU and two with the S7-224 CPU tailored to suit simple or complex automation tasks, giving the best optimised and low-
Each AS-i master can have up to 31 slaves connected to it (62 when version 2.1 est-cost solutions. Easy-to-use, Windows based software unlocks the powerful, in-
slaves become available) built computing and communications features. The enhanced expansion modules allow
Slaves can be digital or analogue and are available in a wide variety of input and more flexible solutions which, coupled with the upgraded software, mean changing
output types from other solutions is easier than ever.
The AS-i master can also perform diagnostics during the CPUs program cycle to All models feature:
identify faults on the bus e.g. faulty slaves High speed 0.37s per instruction In-built power supply
Manual contains all the information needed to install and run the modules, as well 2 x 20kHz pulse outputs PID instructions
as a number of worked examples 1 x RS485 communications interface
INC259
Specifications:
Price Each Supply voltage 85-264Vac, 47/63Hz or 20.4-28.8Vdc
Mftrs. List No. Order Code 1+ 5+ 10+ Supply for sensors 24Vdc, 180mA(221 & 222 CPU) or280mA(224 CPU)
Inputs 24Vdc, 7mA opto-isolated (sink/source configurable)
AS-i master 6GK7 243-2AX00-0XA0 329-0013
Relay outputs Volt free 2A; 5-30Vdc or 5-250Vac
Manual 6GK7 243-2AX00-8BA0 329-0025 Transistor outputs 24Vdc,0.75A
INC257
Optional Cartridges
A range of optional cartridges which allow the user to upgrade the functionality of Telemecanique PLCs
the CPU Nano Base units
The EEPROM memory module is used to transfer and back-up programs and store
data The IEC 1131 compliant Modicon TSX Nano PLC range offers versitility & flexibility at a
The real time clock can be added to the S7-221/222 CPUs low price. With 5 models of base unit to choose from ranging from 10 I/O through to
The battery module retains the integrity of the RAM, typically for 200 days 24I/O, and a range of accessories, the Nano PLC can be easily configured to the
requirements of your small PLC application. Communication protocols include,
INC269
Modbus, Unitelway, and ASCII, and up to 4 of the units can be simply networked to
Price Each share a common data area via their own internal communications link. Three models of
Mftrs. List No. Order Code 1+ 5+ 10+ the Nano PLC have a built in analogue input (0-10V) which can be used to measure
variables such as temperature, speed, level, flow, pressure etc.
Memory module 6ES7 291-8GE20-0XA0 313-9890
Clock module 6ES7 291-1AA20-0XA0 313-9888 Programming is performed in reversible Ladder Logic or Instruction List via PC based
Battery module 6ES7 291-8BA20-0XA0 313-9876 programming software, or Instruction List via a handheld programming terminal. The
addition of a simple program loader makes transfer of programs easy when no pro-
gramming devices are nearby.
S7-200 Cabling 10, 16, and 24 I/O expandable base units
14, and 20 I/O non expandable base units
PC/PPI cable is used for connection between a PC and the programming port on 10, 16, and 24 I/O non expandable base units with 1 analogue input (0-10V)
the CPU 10, 16, and 24 I/O low cost expansion units
Cable length is 5m Real time clock available on 14, 16, 20, and 24 I/O units
The expansion cable is used to connect between rows of modules only one per First input can be configured as a fast counter (up to 10KHz)
I/O chain Programmable input filters on all inputs (12ms, 3ms or 100s)
Price Each
INC270 1000 instruction RAM and EEPROM memory
Protect facility for PLC program (RAM and EEPROM) to restrict unauthorised 26
access
Mftrs. List No. Order Code 1+ 5+ 10+ In built 24vdc sensor supply (150mA) on AC powered units
PC/PPI cable 6ES7 901-3BF20-0XA0 313-9967
Price Each
Software Mftrs. List No. Order Code 1+ 5+ 10+ Nano Expansion Units
CD 6ES7 810-2BC00-0YX0 313-9920 Modicon TSX Nano PLCs can either be expanded by the addition of another expandable
Diskette 6ES7 810-2BA00-0YX0 313-9943 base unit (set to expansion via a selector switch), or via the addition of specific low
Upgrade cost expansion units. These units are available in sizes of 16 and 24 I/O. A maximum of
CD 6ES7 810-2BC00-0YX3 313-9931 one expansion unit can be added to a Modicon TSX Nano PLC.
Diskette 6ES7 810-2BA00-0YX3 313-9955 INC253
Price Each
Supply I/O Mftrs. List No. Order Code 1+ 5+ 10+
110/240V 9 In/7 Out TSX07EX1628 329-5710
110/240V 14 In/10 Out TSX07EX2428 321-5179
continued
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 863
Industrial Computing & PLC's
Telemecanique PLCs Micro Digital I/O Modules
The I/O modules for the Modicon TSX Micro PLCs are supplied complete with terminal
Nano Handheld Programming Devices blocks, and are available in two formats
The handheld programmer for the Nano PLC offers programming and monitoring in Full Height Modules
List language. It can also be used to adjust variables in either the Nano or Micro PLCs. Half Height Modules
It has its own RAM memory which will store a single program for approximately on With the exception of the first slot (which can only accept a full height module), one
hour, and additional Flash Prom memory which will store a single program indefinitely, slot within the Micro PLC rack can be taken either by one full height module or by two
and the ability to add a PCMCIA card into the bottom of the unit which can store up to half height modules. These can be a mix of digital, analogue, safety, or AS-i modules.
6 programs. The 24Vdc input modules have a switch on the card for selecting sink or source mode
The program loader enables a program to be extracted from a Nano or a Micro PLC (PNP/NPN).
(up to 16K words), stored indefinitely, and then if required transferred to another Nano Full height modules are available in the following variants
or Micro PLC. The simplicity of operation via a single button, and the small physical 32 Inputs (24Vdc)
size means that this feature is extremely useful when program modifications need to 32 Outputs (Relay)
be sent to a remote location, or when loading of the program into multiple PLCs is 16 Inputs (24Vdc) / 12 Outputs (Relay)
required. Half height modules are available in the following variants
INC254
12 Inputs (24Vdc)
Price Each 8 Outputs (Relay)
Mftrs. List No. Order Code 1+ 5+ 10+ 8 Input Emergency Stop / Limit Switch Monitoring Module (Safety Relay Module)
INC247
Programmer TFTX11071E 321-5192
EEPROM, 32K TFTXREM3216 321-5209 I/O Price Each
Program Loader TSXPRGLDR 321-5416 Configuration Size Mftrs. List No. Order Code 1+ 5+ 10+
12 In Half TSXDEZ12D2 321-5544
32 In Full TSXDEZ32D2 329-5746
Nano Programming Software 8 Out Half TSXDSZ08R5 321-5623
The programming software package for the Modicon TSX Nano PLC is supplied com- 32 Out Full TSXDSZ32R5 321-5635
plete with the interface cable to connect between the PC and PLC, a programming and 16 In, 12 Out Full TSXDMZ28DR 321-5600
installation manual, and the software on 36" disks. This simple user friendly software
package is IEC 1131-3 compliant, and offers programming in Ladder Logic or
Instruction List, and complete transfer and monitoring facilities for the PLC application, Safety Relay Modules
ensuring swift, programming, diagnostics, and commissioning. This unique module enables the substitution of a standard safety relay module, and the
IEC 1131-3 compliant integration of this function into the Modicon TSX Micro PLC. The module conforms to
Full programming in reversible Ladder Logic or Instruction List EN 954-1, and has BG & INERIS approval.
Full monitoring facilities in reversible Ladder Logic or Instruction List
Ability to document program with both Symbols, and Addresses Module contains a Preventa hard-wired
Ability to force I/O and Data safety relay 2 N/O safety output circuits, category 3
Full transfer facilities between PC and PLC RAM and EEPROM Monitoring of 1 to 4 dual (or single), normally closed contacts in pushbuttons,
Includes connection cable, disks, and manual emergency stops or limit switches on safety guards for an emergency stop or
INC256 immediate safety stop system (category 0)
Used to interrupt one or more emergency or safety stop control circuits in com-
Price Each plete safety
Mftrs. List No. Order Code 1+ 5+ 10+ Safety module independent of the Micro PLC processor
26 TLXLPL707P30E 321-5180 PLC diagnostics performance
Inputs 4 emergency stops or limit switches (dual or single contacts)
1 start button
24V
Micro base units
Industrial Computing & PLC's 864
864 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
INC245
Accessories
Price Each
Extension rack 1 per PLC
Slot cover protects the PLC from ingress of dirt etc. when slots are not utilised Mftrs. List No. Order Code 1+ 5+ 10+
Battery provides backup for the PLC TLXCDPL7MP33M 321-5775
INC236
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 865
Industrial Computing & PLC's
Extremely user friendly IEC 1131/III Comprehensive documentation and
Omron PLCs continued compliant windows based program- commentry
Expansion Units. ming and documentation software Import and export "block" building
Has extensive monitoring and diagnos- Enables a structured approach to pro-
For 'CPM1A' Series
tic facilities for fault gramming
finding and commisioning
Choice of program editors
PLC46
Price Each
Mftrs List No. Order Code 1+ 5+ 10+ 25+
Software SYSWINCPM1 199-977
The 30 and 40 I/O CPUs have expansion capability using either a 20I/O digital unit or a
2 channel input/1 channel output analogue expansion unit. Up to 3 expansion units
may be added to the main CPU unit. Relay and transistor output versions available.
Power is supplied from main CPU.
Specification: Analogue I/O Units
2 analogue inputs (0-10V, 1-5V, 4-20mA)
1 analogue output (0-10V, -10 to + 10V, 4-20mA)
Specification: Digital I/O Units
Inputs 24VDC, 5mA, Opto isolated, NPN/PNP config
Relay Output Volt Free 2A@250VAC; 2A@24VAC
PNP Output 24VDC, 0.3A/point
Mftrs. List No: CPM1A-20EDR=199-904, CPM1A-20EDT1=199-916, CPM1A-MAD01=199-928
PLC45
Output Order Price Each Extremely user friendly IEC 1131/III compliant windows based programming and
Type Code 1+ 5+ 10+ 25+ documentation software
Has extensive monitoring and diagnostic facilities for fault finding and comission-
Digital I/O Expansion Units
ing
12 Inputs, 8 Outputs Relay 199-904
Choice of program editors
12 Inputs, 8 Outputs PNP 199-916
Comprehensive documentation and commentry
Analogue I/O Expansion Unit Import and export for program "block" building
2 Inputs/ Output Analogue 199-928 Enables a structured approach to programming
Programs all Omron C Series PLCs
CQM1-CIF02 is a 2m cable and adaptor that converts the perpheral port on the CPU
Communication Adaptors/Cables to RS232 and can be used for many Omron programmable controllers
For 'CPM1A' Series RS 232CABLE is a standard RS232 cable which connects directly into the CPU
26 RS232 port and can also be used to program Omron HMIs NT11S and NT20S
PLC79
Price Each
Mftrs. List No. Order Code 1+ 5+ 10+ 25+
Industrial Computing & PLC's 866
Programming Console
For all C Series PLCs
Has a two line LCD display
Enables programming of all codes
Allows access to all data memories,
timers/counters and other data areas on
A choice of RS232 and RS422 DIN rail mounting adaptors are available for program- PLC
ming via PC using Omrons Syswin programming software. Connector can be made Supplied with a 2m cable
using the 2m RS232 cable listed below
PLC44
Price Each
Mftrs List No. Order Code 1+ 5+ 10+ 25+
RS232 CPM1-CIF01 737-460
RS422 CPM1-CIF11 737-471
RS232 Cable _ 199-965 H=190, W=90, D=35
PLC154
Price Each
Programming Software Mftrs. List No. Order Code 1+ 5+ 10+ 25+
For 'CPM1A' Series CQM1-PRO01-E 737-513
IMO PLCs
K10 Series Micro
866 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
The K10 micro PLC is a cost effective, block type unit offering 14 I/O (8 I/P, 60/P)
The IMO PLC Software and Programming Tools
Features include:
The IMO PLC software CD is supplied free of charge with
800 step EEPROM memory 48 timers and 16 counters
each purchase of an IMO PLC or HMI.
Processing speed 3.2 to 7.7 sec 16 100 step sequence controllers
per step 256 auxiliary and 128 retentive relays Easy to use IEC 1132-3 compliant Windows based pro-
Built in 8kHz high speed counter 64 data registers gramming simulation and documentation software
Integral RS232 interface Windows 95 drag and drop software Programming can be in either relay ladder sequential
Integral RS485 interface enabling up included fucntion or chart or statement list
to 32CPU's to be linked Enables forcing of inputs/outputs Custom function blocks and custom library can be cre-
3 year guarantee Enables change of timer/counter ated enabling complex programs to be broken down
185 instructions values Programs can be programmed locally or remotely via
Modem or Fnet
Operating voltage 85-265Vac On-line programming modifications possible
Inputs 24Vdc Off-line program simultation can be achieved
Outputs Volt free relay, 2A @ 240Vac or 3Vdc Powerful editing tools available
PLC189 Comprehensive program documentation
Price Each
Mftrs.List No. Order Code 1+ 2+ 5+ 10+ 20+ INC272
G Series CPU
The IMO G6 is a very compact modular programmable con-
troller offering extremely high performance-
Upto 256 I/O
High speed processing with dedicated MPU 0.5 sec per
step
Memory capacity 17ksteps
Conform to elements of the IEC1131-3 standard (IL/LD/SFC)
PID control, computer link, high speed counter
Programming software CD provided
The IMO PLC starter kit is an ideal introduction into PLCs. It includes the small high
Specification
function K10S1 Programmable Controller, KGLWIN Windows based programming soft- Item GM6-CPUA GM6-CPUB GM6-CPUC
ware, all cables and the IMO CD ROM which includes all user manuals and a simple
Operation method Cyclic Operation, interrupt task method
Programmable Controller Tutorial. I/O control method Scan synchronised batch processing (refresh method)
The kit includes IMO K14P1-DRS PLC, KLC-010 programming cable, KLA-009 PC
adaptor and KGLWIN Software CD.
PLC242
Prog lang IEC1131-3 IL (instruction list), LD (ladder diag.) SFC
Operator (LD:13, IL:21), Basic (194), Basic Book (11) Special block
26
Number of instructions (dedicated function block special modules)
Price Each Processing speed Operator (0.5usec), Basic (0.5usec), Basic Block (0.5usec)
Price Each
Part No. Order Code 1+ 5+ 10+ 25+
GM6-CPUA CPU Standard 327-7290
GM6-CPUA CPU RS485, PID, RTC 327-7306
GM6-CPUA CPU PID, RTC, HSC 327-7318
The IMO HMI-PLC starter kit is an ideal introduction to HMI (Human GM6-CPUA PSU AC Standard 327-7320
Machine Interface) and Programmable Controllers. It includes the GM6-CPUA PSU AC Analogues 327-7331
IMO K10S1 PLC, the IMO MI2L20C display, KGLWIN Windows GM6-BO4M 4 I/O Slot 327-7343
based programming software, all programming cables, IMO-HMI GM6-BO6M 6 I/O Slot 327-7355
configuration software and the IMO CD ROM which includes all GM6-BO6M 8 I/O Slot 327-7367
users manuals and a simple introduction.
PLC243 continued
Price Each
Description Order Code 1+ 5+ 10+
PLC-HMI starter kit 353-2707
Major International
Brands
All the leading brand names from over
1,000 major international manufacturers.
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 867
Industrial Computing & PLC's
IMO PLCs continued G7 Micro Controller
G Series I/O
A wide choice of digital and analogue I/O in addition to special purpose
communication cards.
Removable terminal blocks
High speed response
RS232C and RS485 computer links
Fnet module option
Counter module option
Analogue, Fieldbus and DeviceNet modules
INC274
A series of micro programmable logic controllers offering program-
Part No. Order Price Each ming in the international IEC1131-3 programming language con-
Inputs Code 1+ 5+ 10+ 25+ forming to Instruction List IL, Sequential Function Chart SFC and
G6I-D22A 16 24VDC input (NPN/PNP) 327-7914 Relay Ladder LD. Free powerful GMWIN software, Windows based
G6I-D24A 32 24VDC input (NPN/PNP) 327-7926 Win 95,98 and NT is used. The same programming tools and soft-
G6I-D22B 16 24VDC input (source) 327-7938 ware is used as the IMO G6 PLC range.
G6I-D24B 32 24VDC input (source) 327-7940 The G7 can be expanded up to 80 I/O 48 I/P 32 O/P.
G6I-A11A 8 110VAC input 327-7951 Dedicated 32 bit CPU 128Kb RAM plus Flash memory
G6I-A21A 8 240VAC input 327-7963 Processing speed 0.5us/step 64Kb program capacity
Outputs 16kHz high speed counter Direct variable 2-8Kb
G6Q-RY2 16 2A relay output 327-8438 2kHz pulse output Symbolic variable 32Kb
G6Q-TR2A 16 Trans 0.5A (sink) 327-8440 PID autotuning function Timers unlimited 0.001-4,294,967.295
G6Q-TR4A 32 Trans 0.1A (sink) 327-8451 8 pulse catch inputs 0.2ms sec
G6Q-SS1A 8 Triac 100/240VAC 1A 327-8463 8 interrupt inputs 0.6ms Counters unlimited -32768 to 32767
Settable input filters 0-15ms Run, stop, pause, debug mode
Analogue I/O
2 built-in RS232 ports Ch1 fixed 38400 Number of program blocks 128
G6F-AD2A 4 channels 327-8475
bps, Ch2 supports Modbus Time driven tasks 8
G6F-DA2V 4 Voltage O/P 327-8487
master/slave plus user defined proto- External interrupt tasks 8
G6F-DA2I 4 current O/P 327-8499
col 1200-57600 bps Internal interrupts 8
High speed counter RS485 option (G7M-DR10A integral) Real time clock module (RTC)
G6F-HSCA 50kpps counter 327-8505 24V dc output External Flash memory module
Communications 205 instructions
G6L-FUEA 1Mbps 327-8517
Supply voltage: 110/240 AC Inputs: 24V dc 7ma opto isolated (sink/source)
G6L-CUEB computer link RS232 327-8529
Operating temperature: 0-50C Outputs: Relay 2 Amp 24V dc/240V ac
G6L-CUEC computer link R485 327-8530
External Dimensions
Description H W D Mftrs. List No. Order Code
K7 Micro Controller 6 in 4 out ac powered 75 95 115 G7M-DR10A 353-2501
12 in 8 out ac powered 75 145 115 G7M-DR20A 353-2513
18 in 12 out ac powered 75 145 115 G7M-DR30A 353-2525
24 in 16 out ac powered 75 175 115 G7M-DR40A 353-2549
Price Each
Description Order Code 1+ 5+ 10+
Industrial Computing & PLC's 868
AC Supply
10 I/O 353-2501
20 I/O 353-2513
30 I/O 353-2525
40 I/O 353-2549
60 I/O 353-2550
868 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
PLC239
Extension Unit
Mftrs. List Price Each
No. Order Code 1+ 5+ 10+
G7F-RTC 353-2628
continued
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 869
Industrial Computing & PLC's
H W D Mftrs List No. Order Code
IDEC PLCs Expansion Unit 80 140 74 FC1A-E1A1E 179-951
Micro Expansion Units
MICRO-1 Starter Kit 2 I/P & 2 O/P 80 45 74 FC1A-M1BE 709-8911
4 I/P 80 45 74 FC1A-M1XE 709-8893
3 O/P 80 45 74 FC1A-MXAE 709-8900
Analogue timer unit 80 45 74 FC1A-TA1 710-1960
inc47
Price Each
Order Code 1+ 5+ 10+
Expansion Unit 179-951
Micro Expansion Units
2 I/P & 2 O/P 709-8911
4 I/P 709-8893
3 O/P 709-8900
Analogue timer unit 710-1960
Micro 1
Micro 18 inputs and 6 outputs, expandable to 16 inputs and 12 outputs using
expansion unit FC1A-E1A1E
Program capacity 600 steps using either programming unit or software
High-speed scan (8s per instruction)
Relay logic programming
80 timers (0 to 999.9s)
45 counters (0 to 9999)
128 shift registers
Supplied with comprehensive user manual
Starter Kit
Low-cost entry starter kit, complete with base unit, software, interface, cables and
manuals
MICRO-3
Supply Voltage 100 240V ac
Each 10 I/O, 16 I/O and 24 I/O unit can be configured as either a CPU base unit
26 Inputs
Outputs
Mounting
Volt-free contact or NPN transistor (source input)
Volt-free contacts rated 2A 240V (resistive)
35mm symmetric DIN rail or screw mounting
or an expansion unit
Built-in communications allow up to 6 slaves to be connected to a master using an
Indicators Red LEDs for power, run, error, each input and each output RS485 twisted pair network
Programmer 24 colour coded keys, run/stop switch, 16 character LCD. 32 PLCs can be networked to a central computer using the Micro3 networking
Industrial Computing & PLC's 870
Price Each
Unit Order Code 1+ 3+ 5+ 10+ 20+
MICRO-3
10 I/O 710-2173
16I/O 710-2185
24I/O 710-2197
Expansion unit Micro expansion unit (3 O/P) Analogue timer unit MICRO-3C
Expansion of the Micro-1 is possible using either the expansion unit, a Micro 16I/O 722-3857
expansion unit, or an analogue timer unit 24I/O 722-3869
Only one expansion I/O or one micro expansion I/O or one analogue timer unit can
be used per Micro-1 CPU
CPU base unit provides power for expansion I/O Windows Based Programming Software
Expansion Units Programs all Idec Micro PLCs
Doubles Micro-1 I/O to 16 inputs and 12 outputs Runs on Windows 3.1, 3.11, 95 and NT
Micro Expansion Units Comes complete with tutorial
Used for incremental I/O expansion Drag and drop programming from Windows style toolbar
Options available: 2 source inputs & 2 sink outputs, 4 source inputs or 3 relay out- Multi-level undo commands
puts Print preview to display ladder (with mnemonics if desired)
Analogue Timer Unit Open multiple ladder files
Allows changing of timer values without the need to stop the machine Direct monitoring
4 separate time potentiometers, each with 8 different time ranges
Ranges from 0-1 sec through 0-10 Min.
870 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
inc185 4 20 character display
5 two colours LEDs
Price Each 5 function keys
Mftrs' List No. Order Code 1+ 3+ 5+ 10+ 20+ Alpha numeric keyboard capability
WINDLDR 722-4205 Real time clock
RS232 printer port
24V dc operating voltage
INC209
E300
A/D units convert analogue input signals into digital signals for storage within an
internal CPU register The E300 is an HMI that has been designed to simpli-
D/A units convert a digital input value from an internal CPU register into an fy automation display problems. The E300 has a
analogue output range of features to suit most applications and with
Each A/D or D/A uses one input or one output of the PLC its simple programming and screen creation software
gives fast HMI usage in the shortest possible time.
Unit Dimensions
H W D Mftrs List No. Order Code
For software order part number 774-595, page 871
Input 0-10V 80 45 70 FC2A-AD2 710-2306
Input 4-20mA 80 45 70 FC2A-AD4 710-2318
Output 0-10V 80 45 70 FC2A-DA2 710-2320
Output 4-20mA 80 45 70 FC2A-DA4 710-2331
inc52
Real time trend graphs
Price Each Recipe handling
Unit Order Code 1+ 3+ 5+ 10+ 20+ Scrollable text blocks
Input 0-10V 710-2306 Alarm handler
Input 4-20mV 710-2318 Password protection - to device level
Output 0-10V 710-2320 Time channels
Output 4-20mA 710-2331 Connectivity to Mitsubishi and other manufacturers PLCs
Networking options, including Profibus DP
Windows drag and drop prgramming
Micro-3C Communications Cables 2 4 0 64 backlit LCD display
16 two colours LEDs
Modem cable (3m), connects basic unit (loader port) and modem (1:1 8 function blocks
communications) Alpha numeric keyboard capability
With D-sub 25-pin connector to connect to modem Real time clock
PC Interface cable (3m), connects basic unit (loader port) and PC (1:1) RS232 printer port for alarms and report generation inc227
communications)
With D-sub 9-pin female connector to connect to computer
PC Interface cable (2m), connects basic unit (data link terminal) and PC (1:1
Mftrs.
List No. Order Code 1+
Price Each
5+ 10+
26
communications) MAC E300 725-8434
With D-sub 9-pin female connector to connect to computer MAC E300 Manual 725-8458
Operator Interfaces
The E700 and E710 are graphic based HMIs that are user-friendly both for operators
E100 and designers. With the object oriented programming software it is easy to create a
2 line x 20 character backlit LCD dis- RS232 printer port user interface that exactly answers the operators needs. E710 has touch screen. For
play Password protection software order part number 774-595, page 871
4 function keys Connectivity to Mitsubishi and other
Historical trend graphs
Real time clock manufacturers PLCs
Recipe handling
Recipe handler 5Vdc from PLC or external
Scrollable text blocks
Report generation IP65
inc265 Alarm handler
Password protection - to device level
Price Each Time channels
Mftrs. List No. Order Code 1+ 5+ Connectivity to Mitsubishi and other manufacturers PLCs
E100 309-2458 Networking options, (including Profibus DP)
Windows drag and drop programming
E700 E710
E200 Real time clock
RS232 printer port (for alarms and report generation)
The E200 is a compact, powerful Human Machine 24V dc operating voltage
Interface with an abundance of features at an 3 2 0 240 backlit 16 colour LCD display 320 240 backlit 16 colour LCD
affordable price. For software order part number LCD display display - touch screen
774-595, page 871. 14 two colour LEDs 8 two colour LEDs
16 function keys 8 function keys
Scrollable text blocks Alpha numeric keyboard capability inc228
Alarm handler
Password protection to device level Mftrs. Price Each
Time channels List No. Order Code 1+ 5+ 10+
Connectivity to Mitsubishi and other manufac- MAC E700 725-8460
turers PLCs MAC E710 725-8471
Windows drag and drop programming E700/710 Manual 725-8483
continued
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 871
Industrial Computing & PLC's
Operator Interfaces continued Operator Interface -NT2S
Displays with alphanumeric screens are used to represent variables and messages The NT2S operator interface is a low cost unit for use with all Omrom C series PLCs.
Various keys can be used to modify variables, control the device or browse in a dia-
Features include:
logue application
2 line, 32 character LCD display
Uni-Telway version is developed specifically for use with the Telemecanique PLC
6 function keys
protocol
Embedded variables and data entry possible
Other versions use the communication protocols within the software package,
IP65 NEMO 4 rated
Order Code 321-6056
8k EEPROM memory
Matrix display version can be used to display bitmap images and animated bar
chart and gauge objects Mftrs. List No. NT25-SF123B-4=305-5656 PLC201
Uni-Telway version is LCD, multiple protocol version has back-lit LCD
Price Each
Power Supply 24Vdc, multiple protocol version is 5V during operation
(from Nano/Micro PLC) Order Code 1+ 5+ 10+ 25+
No. Keys 5 service keys Non-programmable, 9Vdc 305-5656
Protection IP65 INC251
HMI - PLC cable - 2m 305-5668
HMI - PLC cable - 5m 305-5670
Price Each
20 x 20 characters Mftrs. List No. Order Code 1+ 5+ 10+
Uni-Telway XBTF011110 321-5994 Operator Interface - 'NT11S'
Multiple XBTH011010 321-6007 Features include
8 x 40 characters Flash memory - no need for batteries
Matrix Display XBTHM017010 321-6019 IP65 NEMA 4 - withstands water and oil
RS232 and RS422 ports as standard
Printer port
Magelis Graphical Displays Password screens for security
Keypad and Touchscreen Large keys for numeric data entry
Graphical display terminals available in either keypad or touchscreen formats Simple to use - simplifies ladder
Keypad version has 5.7" monochrome screen H=113, W=218, D=38.2 programming
Panel Cut-out 98 203 Long lived easy access
Touchscreen format has 5.7" or 10.4" colour screen
Specially designed for operator dialogue graphic functions Bar graph facility
Dynamic visualisation of operating data (setpoints, measurements, recipes, mes- UL & CSA approved CE marked
26
sages) and process errors
Scaling of analogue variables
The NT11S operator interface is a slim operator that stands up well to harsh enviro-
ments. A 4 line display that can accept embedded data and robust numeric and user
Alarm log and management of alarm groups definable function keypad makes the NT11S ideal for machine status and control
Three levels of password Realtime and trending curves
Supply voltage 24Vdc (-15% +10%) Operating temperature 0 to +50C
Industrial Computing & PLC's 872
Price Each FOR SUITABLE SOFTWARE SEE ORDER CODE 201-455 PAGE 873
PLC40
Keypad Mftrs. List No. Order Code 1+ 5+ 10+
5.7 XBTF011110 321-6020 Price Each
Touchscreen Mftrs List No. Order Code 1+ 5+ 10+ 25+
5.7 XBTF032110 321-6032 Display NT11S-SF121 201-431
10.4 XBTF034110 321-6044
Connection cables are used to connect the terminals to most of the major PLC brands Touch screen operator interface for use Lamps and touch switches
in the market. with all Omron PLCs Bargraphs
Note: Adaptor, Order Code 329-0311 must be used with Siemens cable, Order Code Features include: RS232 port for programming and PLC
321-6135. Flash memory - no need for batteries - HMI comms
INC252 Transparent communications - no User definded graphics available
Price Each interfacing software Alpha string handling
Up to 500 screens In-built thumbwheel data entry
Mftrs. List No. Order Code 1+ 5+ 10+
LCD display with 128 256 dot resolu- 1:1 and 1:n configurations supported
Software XBTF011110 321-6056 tion UL & CSA approved
Manual XBTH011010 321-6147 IP65 enclosure CE marked
Connection cable
Power supply 24DC (-15% +10%)
Modicon TSX XBTZ968 321-6068 Power consumption 10W max.
Allen Bradley - SLC500 XBTZ9730 321-6070 Operating temperature 0 to 50C
Allen Bradley - Micrologix XBTZ9731 321-6081 Meet standards EN61131-2 (MAC-D) (1984), EN50081-2(EMC-D) (1992)
Omron - CQM/CVM RS422 XBTZ9740 321-6093
Omron - CVM RS422 XBTZ9741 321-6100 FOR SUITABLE SOFTWARE SEE ORDER CODE 201-467 PAGE 873
PLC41
Siemens - S7-200 XBTZ9721 321-6111
Siemens - S7-CP525 XBTZ9720 321-6123 Order Price Each
Siemens - S5 AS511 Port XBTZ909 321-6135 Mftrs List No. Code 1+ 5+ 10+ 25+
Adaptor - use with 321-6135 XBTZ939 329-0311 Display NT20S-ST121-EV3 201-443
872 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Programming Software and Cables 320 240 5.7" monochrome or colour Ethernet port
For Omrons 'NT11S' and 'NT20S' Operator Interfaces LCD display with CCFL backlight Resistive touch
512K Flash, 128K RAM Win CE operating system
PC based programming package allows generation of screens for the Omron NT11S 2 serial ports RS232 and IP65 NEMA4
and NT20S. Screens can easily be designed with a mouse driven interface and PLC RS485/RS422 Password screens for security
data areas assigned to dynamic functions such as bar graphs, character strings, touch Parallel port User friendly configuration
switches and lamps very easily . User defined symbols can be accessed using the Real time clock Connectivity to IMO PLCs and others
"mark" facility. Full saving editing and copy function are available. RS232CABLE 16 programmable keys, 16 system Expansion capabilities
allows programming of the HMIs whilst the CABLE2 connector allows communication keys CE marked
between PLC and HMI 2 status, 10 dual col. programmable
PLC42 LEDs
Price Each Supply voltage: 9-35V dc Operating temperature: 0-50C
Mftrs List No. Order Code 1+ 5+ 10+ 25+ PLC229
4 and 8 lines, 20 and 40 characters 2 status, 10 dual col. programmable Ideal for replacing conventional panel designs using lamps, mimics and pushbuttons.
LCD display with LED backlight LEDs Features include:
128K Flash, 32K RAM IP65 NEMA4 Mono black & white or mono blue LCD options
2 serial ports RS232 and Password screens for security 240 128 pixel 4.2" graphic display
RS485/RS422 User friendly windows configuration 128k flash EPROM memory
Parallel port Connectivity to IMO PLCs and others 16 programmable function keys
Real time clock Expansion capabilities 1 input, 2 outputs
16 programmable keys, CE marked 24V dc supply
16 system keys Drivers for IMO PLCs plus other manufacturers
Supply voltage: 9-35V dc Operating temperature: 0-50C Integral RS232 port
PLC231 PMU screen configuration software provided
Prices Each PMU-200BN-FAR 327-8827 PMO-200S-FAR 327-8852
Mftrs. Part No. Order Code 1+ 5+ 10+ PMU-200LN-FAR 327-8839
INC279
MI4L20CX-FAR 353-2756
MI4L40CX-FAR 353-2768 Price Each
MI8L40CX-FAR 353-2770 Order Code 1+ 5+ 10+ 25+
Blue LCD 327-8827
Operator Interface - 320 240 Monotouch Black & White LCD 327-8839
RS485 Serial Interface 327-8852
or Colourtouch
continued
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 873
Industrial Computing & PLC's
inc64
Operator Interfaces continued
Mftrs. Price Each
Operating Interface List No. Order Code 1+ 5+ 10+ 15+ 20+
PMU300 CL10 711-0789
CL15 711-0790
CL20 711-0807
874 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
PLC204 Terminal Bases
Price Each A-B Part Number Terminal Style Order Code
Mftrs. List No. Order Code 1+ 3+ 5+ 1734-TB Screw 351-6519
1734-TBS Spring Clamp 351-6520
1794-IB16 351-5928
1794-OB16 351-5930 Communications Adapters
Order Code
1794-OW8 351-5941
1794-IE8 351-5953 1734-ADN Full DeviceNet Adapter supports 63 I/O modules 351-6544
1734-PDN DeviceNet Interface, supports 12 I/O Modules,
1794-OE4 351-5965 each module is a DeviceNet node 351-6532
Accessories
Order Code
Flex I/O System 1734-FPD Field Potential Distributor, used to create new AC, DC or Analogue
Communications Adapters Power buses. For use with 1734-PDN 351-6556
1734-EP24DC Field Potential Distributor, used to create new AC, DC or Analogue
Supports up to 8 Modules Power buses. For use with 1734-ADN 351-6313
Requires 24V dc Power
Diagnostics for communi- The voltage distribution modules provide two important functions. Partitioning and bus
cations extension.
Partitioning is divided into logical and functional partitioning:
1. Functional partitioning means grouping together modules of similar signal types that
perform specific functions such as sequential control, axis or motion control, or
process control.
2. Logical partitioning is dividing groups by I/O type thereby separating analogue and
PLC205
digital signal power sources. Digital signals may be divided into AC and DC.
Mftrs. Price Each Field Potential Distributor
List No. Description Order Code 1+ 3+ 5+
The field potential distributor allows you to convert your field power so that you may
1794-ASB Remote I/O 333-8332 have a broad range of voltage inputs in your 12-module system. This range of voltage
1794-ADN DeviceNet 351-5916 inputs includes 5V dc to 240V dc and/or 5V ac to 264V ac applications and I/O
modules.
PLC218
Point I/O is a family of modular input and output modules that highlight ease of use,
effeciency, ergonomics and economics. The Point I/O system is ideal for applications
where flexibility and low cost of ownership are key for successful control system ArmorBlock LP2 is an IP67 packaged I/O product designed for use in harsh manufac-
design. turing environments. These blocks require no enclosure and can be mounted directly to
Colour coded components for easy maintenance machinery or equipment where sensors or actuators are placed. The ArmorBlock LP2
Removable I/O cards and terminal strips products have DeviceNet built-in and connect directly to a DeviceNet network.
Small, modular design Autobaud detection eliminates potential for incorrect baud rate problems
System, node and point level diagnostic feedback via LEDs Electronically protected outputs automatically protects outputs from over current
Just what you need I/O and short-circuit conditions
Select the I/O modules that you need from the list below, (each module requires a Hardware Watchdog circuitry puts outputs in known state if internal failure occurs
base, see terminal bases). Finally, choose the communications adapter from the sec- IP67 Rated -25C to 60C operation 1200Psi Washdown
tion below. ArmorBlock LP2 I/O Digital Modules
Point I/O Digital Modules Inputs: DC 10-30V dc rated Outputs: DC Transistor 10-30V dc, 300m
Inputs: DC 10-29V dc rated Outputs: Relay Volt free 2.A @ 5-265V ac, No. of 12mm
2A @ 24V dc A-B Part Number No. Inputs No. Outputs Connectors Order Code
DC Transistor 10-29 V dc, 1A
1792D-2B2LP 2 2 4 351-5850
A-B Part Number Input Type No. Inputs No. Outputs Order Code 1792D-4B0LP 4 - 4 351-5862
1792D-4BT4LP 4 4 4 351-5874
1734-IB2 DC 2 351-6465
1792D-16BT0LP 16 8 351-5886
1734-IB4 DC 4 351-6477
1792D-0BT16LP - 16 8 351-5898
1734-OB2E 2 transistor 351-6489 PLC219
1734-OB4E 4 transistor 351-6490
1734-OW2 2 relay 351-6507 Price Each
Analogue Modules Mftrs. List No. Order Code 1+ 3+ 5+
1792D-2B2LP 351-5850
Module Type Specification A-B Part No. No.
Number Inputs Outputs Order Code
1792D-4B0LP 351-5862
Input 0-20ma, 4-20ma, 16 bit resolution 1792D-4BT4LP 351-5874
Single ended Inputs 1794-IE2C 2 351-6441
1794-OE2C 2 351-6453
1792D-16BT0LP 351-5886
Output 0-20ma, 4-20ma, 16 bit resolution 1792D-0BT16LP 351-5898
Single-ended Outputs
continued
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 875
Industrial Computing & PLC's
The InterBus S remote bus cables are for connecting host controller boards for PLC's
Fieldbus continued computers, Bus terminals and input/output modules. Remote installation Bus cable
Dioplex FieldBus I/O Modules,
R
incorporates 3 additional conductors for the supply of modules and connected sen-
sors/actuators. This cable is required when using the IP67 I/O modules featured in the
IP67
catalogue. This cable is also suitable for continuous flexing applications as encoun-
tered in C tracks.
ProfiBus Cable
The ProfiBus cable is suitable for connecting host controllers to Bus connected devices
DeviceNet Cable
The Belden DeviceNet cables are suitable for DeviceNet trunk and drop connections
26 InterBus S
InterBus S
8
8
6mA
6mA
Remote
BusTerminal
Remote
As Interbus
S DIN 19258
As Interbus
708-5710
708-5795
Installation Bus S DIN 19258
InterBus S 8 4 4 6mA 2A Remote As Interbus 708-5801
Industrial Computing & PLC's 876
InterBus S Cable
876 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
RS232C 'D' Kits - 25 Way Connectors for Dioplex I/O Modules
R
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 877
Industrial Computing & PLC's
Micro PLC with integral AS-interface master, commands and controls all AS-inter-
AS-I continued face protocol functions
Built-in decoupling circuit for AS-interface power supply unit
AS-i InterBus-S Gateway 5 I/O, 3 inputs 24V dc (one high speed 3.5khz) and 2 independent outputs
Used with the InterBus S Bus coupler, 2A/250Vac or 0.5A/24V dc
the AS-i gateway provides a connec- Up to 124 binary switching I/O devices via AS-interface
tion to InterBus-S 64 timers, 32 counters, 512 (Max.) internal logic relays
Up to 8 InterBus gateways can be con- 1100 step EEPROM programme memory
nected to each bus coupler Programmed in relay ladder, function chart or word based logic using RPX C3
Ideal for complex systems where the WindowsT-based software
high speed communication capabilities Lithium battery available for real-time clock applications
of InterBus-S are of prime importance Conforms to LV and EMC directives
Incorporates fault diagnosis and pro-
Mftrs. List No. Order Code
gramming features Micro Controller with AS-i 7388175 710-4455
Multidrop capability 230V ac to 24V dc power supply 88758903 710-4479
DIN rail mounted Lithium Battery for real-time clock 8875305 710-4698
inc61
Price Each
Order Code 1+ 3+ 5+ 10+
inc3
Micro Controller with AS-i 710-4455
Price Each Power Supply 710-4479
Mftrs. List No. Order Code 1+ 3+ 5+ 10+ 20+ Lithium Battery 710-4698
As-i to Inter-Bus
S Gateway VAG-IBS-K1 704-4586
InterBus S Software and Cable
Bus Coupler VSV-ST24BKT 720-6884
26
Application uploading and downloading
Program testing using real-time graphic animation
inc4
Lithium battery available for real-time clock applications
Conforms to LV and EMC directives
Mftrs. Price Each
Industrial Computing & PLC's 878
Price Each
Order Code 1+ 3+ 5+ 10+
AS-i Power Supply 2,5A; 30Vdc
Software, Cable & Access. 710-4674
Designed for use with the ASi-system
Dual voltage input, either 115V ac or 230 V ac
30V dc-2.5A output incorporates decoupling
circuit to allow AS-i communication to operate
AS-i Hand Held Address Programmer
DIN rail mounted Compact hand-held unit for use with a whole range of
AS-i modules and sensors
Allows easy address programming of the AS-i
devices
Simple operation
Battery operation allows flexible on-site operation
inc8
Price Each
Type Order Code 1+ 3+ 5+ 10+
VAN-115/
230AC-K6 707-6885
inc9
PLC with Integral AS-i Master
Mftrs. Price Each
List No. Order Code 1+ 3+ 5+ 10+ 20+
VAP-HH1 707-7038
878 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
inc38
AS-i User Input/Output Interface Modules
1m Length Price Each AS-interface input/output user mod-
Mftrs. List No. Order Code 1+ 10+ 20+ 50+ 100+ ules with terminals for sensor inputs
AS-i CABLE-YELLOW 709-1333 and actuator outputs
AS-i CABLE-BLACK 709-1345 . 4 Output, 4 Input, or 2 O/P and 2 I/P modules
available
Fits onto base modules, see Order Code
708-9090 or 708-9107
AS-i I/O Modules IP20 Sensors are attached using M12 connectors
Actuator switching up to 2A
Sensor operating energy up to 200mA
As-i I/O modules
H-27, W=45, D=80
Integrated diagnostic LED for switching status
Semiconductor versions with watchdog function
Supplied complete with name plates, screws and seals
Certified by the AS-interface association
Protection Class IP67
inc34
Price Each
Mftrs. List No. Order Code 1+ 3+ 5+ 10+ 20+
4 O/P ASIAM07FAAAA 708-8954
IP20 AS-I slave modules
4 I/P ASIAM06EEEE 708-8966
For connection to 1 to 4 standard sensors and actuators
2 O/P,
DIN rail mounting
2 I/P ASIAM08FEAA 708-8978
Accepts 2-wire round or flat (1.5mm2 or 2.5mm2)
LED indication of input and output status
Versions Description Mftrs. List No. Order Code
4 inputs 2 2 wire and 2 3 wire, 24V dc 88755401 710-6348 AS-i Base Modules for Flat and Round Cables
4 outputs 4 normally-open relay outputs 73880179 710-6361
2 I/P & 2 O/P 2 24V dc inputs (3-wire), 2 normally
open relay outputs 88755404 710-6373
inc63
Price Each
Order Code 1+ 3+ 5+ 10+ 20+
4 I/P 710-6348
4 O/P 710-6361
2 I/P & 2 O/P 710-6373
AS-interface base modules for connection to either flat or round bus line
4 Penetration technology provides reliable connection to flat cable
AS-i Flat Pack I/O Interface Modules Screw terminal technology for reliable connection to round cable
Price Each
Range of AS-i input and output modules in flat style housing. AS-i connection made Order Code 1+ 3+ 5+ 10+ 20+
via AS-i flat cable. Inputs made via M12 connectors. Inputs suitable for 2-wire or 3-
Base for flat bus cable 708-9090
wire PNP sensors or switch contacts. LED indications for inputs and outputs and
Base for round bus
power supply. Solid state outputs powered via separate power supply connection.
cable 708-9107
inc40
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 879
Industrial Computing & PLC's
AS-I continued AS-i Photoelectric Sensors
AS-i Modules Accessories
Empty modules can be used for integration of customer-specific PCBs into the
standard AS-i housing Direct detection (diffuse) and retro-reflective photoelectric sensors
Module lid can be used with either round or flat cable AS-i base units to construct Sensing distances from 300mm for the compact F3 style sensors, up to 10m for
AS-i network junction boxes the larger 'block' style
Protection class IP67 Sensing ranges can be adjusted
Mftrs. List No. Order Code Ingress protection to IP66
Empty Module ASIAM00XXXXP 708-9181 Nominal
Lid ASIDK 708-9193 inc37 Sensing Sensor Includes Dimensions
Range mm Type Reflector H W D Mftrs. List No. Order Code
Price Each 500 Direct Detection n/a 30 30 91 OCT500-M1A-B3 706-5760
Order Code 1+ 3+ 5+ 10+ 20+ 3000 Retro-Reflective no 30 30 91 OCS3000-M1A-B3 706-6892
Empty Module 708-9181 800 Direct Detection n/a 64 25 75 OCT800-F8-B3 706-6909
5000 Retro-Reflective yes 64 25 75 OCS5000-F8-B3 706-6910
Lid 708-9193
2000 Direct Detection n/a 40 40 118 OCT2000-U9A-3 706-6922
10000 Retro-Reflective no 40 40 OCS10M-U9A-B3 706-6934
inc7
AS-i Inductive Sensors - Cylindrical
Price Each
Order Code 1+ 3+ 5+ 10+ 20+
706-5760
706-6892
706-6909
706-6910
706-6922
706-6934
Robust connection
Ingress protection to IP67
Industrial Block Type Sensors
Inductive AS-i sensors with 2mm to 15mm sensing ranges
Cylindrical stainless steel threaded bodies Compact connector allowing simple connection between AS-i flat cable and stan-
Housing diameters range from 12mm to 30mm dard, round, 2-core cable
M12 connection Connector simply clips over AS-i flat cable to make a reliable connection
Tough stainless steel housings
inc41
Ingress protected to IP67
Mftrs. Price Each
Cyndrical List No. Order Code 1+ 3+ 5+ 10+ 20+
Nominal Sensing Thread Dimensions
Range mm L Mftrs. List No. Order Code VAZ-T1-G2F 706-5760
2 12 60 NCB2-12GM60.B3-V1 705-0630
4 12 60 NCN4-12GM60.B3-V1 705-5146
5 18 60 NCB5-18GM60.B3-V1 705-6400 M8 and M12 Self-Assembly
8 18 60 NCN8-18GM60.B3-V1 705-6679
10 30 80 NCB10-30GM80.B3-V1 705-6760
15 30 80 NCN15-30GM80.B3-V1 705-6771
Block Type
Nominal Sensing Flush Mountable Dimensions
Range mm in metal H W D Mftrs. List No. Order Code
15 no 30 30 91 NCN15-M1A-B3 705-8913
15 yes 40 40 118 NCB15-U9A-B3 705-8925
20 no 40 40 118 NCN20-U9A-B3 705-8937
30 no 40 40 118 NCN30-U9A-B3 705-8949 Self-assembly
40 no 55 55 128 NCN40-U9A-B3 705-9206 Standard interface IEC 947-5-2
inc5 Protection class IP67
M8 version requires no special tools-innovative insertion technology
Nominal Positive-screw lock nut
Sensing Range Price Each
Moulded cable versions available in Sensors Section Circular connectors for con-
mm Cylindrical Order Code 1+ 3+ 5+ 10+ 20+ nection to AS-interface modules and sensor devices. Available in 8mm or 12mm
2mm 705-0630 diameters.
4mm 705-5146 Mftrs. List No.
5mm 705-6400
8mm Female Straight ELKA4008V 933367100
8mm 705-6679 8mm Male Straight ELST4008V 933407100
10mm 705-6760 12mm Male Straight ELST4012PG9 933162100
15mm 705-6771 12mm Female Right angle ELWIKA4012PG9 933174100 inc39
Block Type
15mm 705-8913 Price Each
15mm Flush 705-8925 Order Code 1+ 10+ 50+ 50+ 100+
Mountable 8mm Female Straight 709-1450
20mm 705-8937 8mm Male Straight 709-1461
30mm 705-8949 . 12mm Male Straight 709-1473
40mm 705-9206 12mm Female Right angle 709-1485
880 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
G4PB8 8 position I/O rack, barrier termination for field,
Single Channel I/O Modules 50 way IDC for control 7219088
G4PB16 16 position I/O rack, barrier termination for field,
G4 Digital I/O OPTO22 50 way IDC for control 7219090
G4PB16I 16 position I/O rack, barrier termination
for field and control, supporting both
negative and positive true output module configurations 7219106
G4PB16T 16 position I/O rack, barrier termination for field and control 7219118
G4PB24 24 position I/O rack, barrier termination for field,
50 way IDC for control 7219120
Ancillaries
G4 I/O mounted in a 16 way rack with G4STRAP, G4SWIN Switch module input simulator 7219180
8 way I/O rack for PC connection G4SWOUT Switch module output simulator 7219192
G4STRAP Insulated common connection strap 7219209
Generation 4 (G4) digital modules are single-channel I/O circuits with integral status Fuse Spare fuse for modules 581320
LEDs and integral fuses on the output modules. The modules are designed to work inc183b
with 5 and 24 VDC logic voltages and to plug into the Generation 4 family of I/O
mounting racks only. Price Each
Order Code 1+ 10+ 25+ 50+ 100+
AC Input Modules.
721-8904
Used for sensing ON/OFF AC voltages
721-8916
Designed with filtering on the input and a hysteresis amplifier for high noise
721-8928
rejection and transient-free clean switching
721-8930
Each module provides up to 4,000 V rms of optical isolation between field inputs
721-8941
and the logic side of the circuit
721-8953
Applications include sensing the presence or absence of voltage, or sensing
721-8965
contact closures from typical sources such as thermostats, proximity,limit, selector
721-8977
pushbutton and toggle switches
721-8989
DC Input Modules 721-8990
Used for sensing ON/OFF DC voltages 721-9003
Designed with filtering on the input and a hysteresis amplifier for high noise 721-9015
rejection and transient-free clean switching.(except G4IDC5B and G4IDC5K) 721-9027
G4IDC5B and G4IDC5K modules are fast-switching and very fast input modules for 721-9039
signals produced by photoelectric switches, encoders, DC proximity switches, or 721-9040 .
TTL devices 721-9052
Each module provides up to 4,000 V rms of optical isolation between field inputs 721-9064
and the logic side of the circuit 721-9076
Applications include sensing the presence or absence of voltage, or sensing 721-9088
contact closures from typical sources such as TTL compatible devices, proximity, 721-9090
limit, selector, pushbutton, toggle and photoelectric switches 721-9106
AC Output Modules. 721-9118 .
Used for the controlling or switching of AC loads 721-9120
Each module provides up to 4,000 V rms of optical isolation between the field 721-9131
devices and the control logic 721-9143
Modules feature zero voltage turn-on and zero current turn-off 721-9155
Aplications include switching AC relays, solenoids, contactors, motor starters,
heaters, lamps and indicators
721-9167
721-9179
26
DC Output Modules. 721-9180
Used for controlling or switching DC loads 721-9192
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 881
Industrial Computing & PLC's
Single Channel I/O Modules continued Voltage Trip Board
Buffered Output Modules
MOS logic/microprocessor compatible Inverting/Non inverting options
Output for photocoupler/LED status display
Input Current Maximum Maximum Order
Type Voltage Range vs Voltage Load Voltage Load Current Code
Non-inverting 360V dc OUT 75A @ 0.8V dc 60V dc 3.5A dc @ 45C 308-638
Non-inverting 12140V ac OUT 75A @ 0.8V dc 140V ac 3.5A RMS @ 45C 308-640
Non-inverting 24280V ac OUT 75A @ 0.8V dc 280V ac 3.5A RMS @ 45C 308-651
Inverting 360V dc OUT 75A @ 2.4V dc 60V dc 3.5A dc @ 45C 308-663
Inverting 24280V ac OUT 75A @ 2.4V dc 280V ac 3.5A RMS @ 45C 308-687 H=18, W=64, L=100
Mounting 4 holes 3 dia, Fixing centres=84 49
AC Buffered Output Modules 6411, 6412 DC Buffered Output Modules 6311 (can be mounted on pillars above tachometer board 179-932)
(non-inverting), 6421, 6422 (inverting) (non-inverting), 6321 (inverting)
(Black Case) (Red Case) Voltage level detector with variable input & hysteresis
Active O/C PNP & NPN outputs (SIL relay & opto options)
Inverting or non-inverting Input-to-Output logic
Uses MAX8211-NO output jitter or oscillation
100% tested, PLC compatible, wide supply range
Supply +9 to +30Vdc (<6mA)
Trigger voltage +2.3 to +7.5V, Pot. adjustable (range can be modified by resistor addition)
*A non-inverting buffered output module turns on when pin 4 is held in the low state (logic 0), the Field connections Via 8 way screw terminal block
same as standard modules. An inverting module conversely turns on when pin 4 is held high, Indicators Red power and output LEDs
(logic 1). Mftrs. List No MSLD3/1
PLC134
FOR SIL RELAYS, SEE 176-577 TO 176-579, SECTION 4.18
Mftrs. Price Each PLC18
List No. Order Code 1+ 10+ 100+
Price Each
dc module 6311 308-638
Order Code 1+ 5+ 10+ 25+
ac module 6411 308-640
ac module 6412 308-651 179-933
dc module 6321 308-663
ac module 6422 308-687
Industrial Computers
Mounting Boards Industrial PC 12.5 Inch
Mftrs. Price Each
List No. Order Code 1+ 10+ 50+
8 way MS-8H .308-699
16 way MS-16H 308-705
882 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
System Requirements: CRT Bezels
386 or better CPU DOS 3.3 or better (for installation only)
4MB RAM memory (SoftPLC), 16MB I/O interface cards and/or fieldbus cards A range of CRT Bezels manufactured in
(SoftPLC + Java JVM) black ABS plastic, UL94HB rated
4MB fixed disk (SoftPLC), 16MB fixed disk Comms, interface (e.g. COM port, Front mount bezel has a clip fitting for
(SoftPLC+Java JVM) Ethernet card) panels up to 3mm thick
Parallel port Windows 95 or NT, 5MB available Rear mount type can be mounted with
SPZ-1K-SOFTPLCKERNEL 328-0317 TDSPZ-FNW 328-0330 adhesive, double sided tape or screws
SPZ-2K-SOFTPLCKERNEL 328-0329 SPLIC-PTK 328-0342 (see Sections 7 and 11).
INC275
Industrial Monitors
10" Multi Frequency Colour
Design for use with
many industrial based control systems as a
Rear Mounting
replacement or upgrade monitor
With video resolutions from CGA (640 x 200)
to SVGA (800 x 600)
Cut-out in
The monitor provides connection for analogue: Front Panel
R
RGB (5 x BNC) & VGA: (high density 15 way Size Mounting sph. R1 R2 R3 a b c d e f g h i L W
D)
Front
The 10" monitor is housed in a durable metal 5" 350 3 2 5 102 78 110 85 6 13 15 11 2.5 116 91
case designed for heavy industrial applications
Front 3 193 143
H=253, W=259, D=313
and may be stacked 9" 635 3 2 6 180 130 187 137 6 11 15 8
Rear NA 200 150
CRT 12" Front 635 5 6 8 240 170 250 180 8 14 20 8 3 259 189
Size: 10" Dot Pitch: 0.26mm
Screen: Black matrix (anti-reflective, anti-static) to MPRII standard OC203
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 883
Industrial Computing & PLC's
General purpose input/output card
Data Acquisition Cards continued 8255 compatible, inputs and outputs
44 Channel Multi-Function 3 on-board 16 bit counter timers (8254 compatible)
Facility to fit pull up/down resistors on inputs
PCI-ADC
1 50 way male D type connector
PLC227
Price Each
Mftrs. List No. Order Code 1+
PCI-PIO 723-4831
Watchdog Timer
PCI-WDT
Designed to read several sensor ranges which make this card ideal for multi-point data
logging.
8 differential inputs or 16 single-ended inputs. 12 bit resolution
4 12 bit analogue outputs
24 programmable digital I/O channels at TTL levels
3 on board 16 bit Counter Timers (8254 compatible)
Suitable for monitoring input voltages with a full scale reading as low as 5mV
Sample and hold amplifier provides accurate readings at varying input signals
Analogue voltage and current outputs are bi-polar
Digital inputs can be either voltage or volt free contacts
Software configurable
Auto calibration Automatically monitors critical PC functions to predict serious problems before they
1 50 way male D type connector happen giving time for corrective actions to be taken.
PLC208
On-board Watchdog timer
Price Each Power rail monitoring
Mftrs. List No. Order Code 1+ Isolated digital input
PCI-ADC 723-4818 Digital and relay output
Monitors hot spots in computer system using remote temperature sensor
On-board audible alarm
All functions selectable under software control
32 Channel Isolated Digital Input/Output I/O connections via two part screw terminal
PCI-DIO PLC225
Price Each
Mftrs. List No. Order Code 1+
26 PCI-WDT 723-4843
Price Each
Mftrs. List No. Order Code 1+
PCI-WINNT 723-4855
Designed as a general purpose interface to most other digital devices ie. switches,
LEDs and parallel ports.
884 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
24 Channel Opto-isolated Digital Input Multi-channel Digital Combination
DIP-24 DCM-16
Designed to offer a wide range of digital input/ output and pulse handling facilities.
Interrupt facilities enable the card to be used where digital inputs trigger other events,
Designed for sensing inputs from switches or volt-free contacts in industrial or labora- or where timed interrupts initiate other inputs, scanning or control.
tory conditions.
8 opto-isolated inputs 8 opto-isolated Darlington outputs
24 digital input channels 3 16 bit counter/timer On-board clock source
Fully opto-isolated to 500 volts Link selectable interrupts 50 way IDC connector
Inputs configurable from 5 to 24 volts AC/DC PLC248
Designed as general purpose interfaces to other digital devices ie. switches, LEDs and Provides the capability for counting pulses, complex pulse generation, stopwatch tim-
parallel ports. ing, coincidence alarms and much more all under software control.
48/96 digital channel options Programmable as input or output 10 programmable channels Counter/timer/generator functions
Configurable under software control 5 volt TTL logic signals 16 bit counters, cascadable 50 way IDC connector
50 way IDC connector Full interrupt support 4MHz on-board clock
PLC247 Programmable pulse outputs 50 way IDC connector
PLC250
Price Each
Mftrs. List No. Order Code 1+ Price Each
P10-48 176-927 Mftrs. List No. Order Code 1+
P10-96 343-4850 DPC-10 176-928
continued
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 885
Industrial Computing & PLC's
Data Acquisition Cards continued 8 Channel 12 Bit Analogue Output
AOP-8
48 Channel Opto-isolated Digital
Input/Output
DIO-48
Designed to drive external devices ie. controllers and motors, can also be used where
Ideal for activating relays and solenoids in process control applications.
an analogue control voltage up to 10mA is needed.
24 opto-isolated digital input channels 24 opto-isolated digital output channels
8 independent analogue outputs 12 bit resolution
Fully isolated to 500V Input range from 5 to 24 volts AC/DC
0-10 volts, programmable output 1.5S settling time
Switches up to 24V DC Darlington drivers sink up to 400mA
Non-linearity 1 bit 50 way IDC connector
Optional on-board voltage sources Two 50 way IDC connectors
PLC254
PLC251
Price Each
Ideal for activating relays and solenoids in process control applications. Mftrs. List No. Order Code 1+
16 digital input and 16 digital output channels ADC-44D 343-4898
Fully isolated to 5400V Link selectable interrupts
3 16 bit timers (82C54) 50 way D-type connector
PLC252 Multi-function 12 Bit Combination
Price Each ADC-42
Mftrs. List No. Order Code 1+
DIO-32D 343-4886
Price Each
Ideal for reading up to 24 analogue voltages from the shop floor.
Mftrs. List No. Order Code 1+
24 single ended or 12 differential channels 12 bit ADC uni/bi-polar operation
Up to 8S conversion 20KHz throughput ADC-42 178-061
Programmable gain amplifier Sample and hold amplifier
50 way IDC connector
PLC253
Price Each
Mftrs. List No. Order Code 1+
AIP-24 176-930
886 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
8 Channel Analogue to Digital Multi-function Watchdog
AIP-8 WD-1
Price Each
Price Each
Mftrs. List No. Order Code 1+
Mftrs. List No. Order Code 1+
WD-1 343-4930
AIP-8 343-4904
2 serial channels
Link selectable RS232/422/485 or
20mA loop
Selectable interrupt channel
Selectable base address 26
Parallel port option
16C550 UART Windows option3
Ideal for driving stepper motor controllers or any device requiring an analogue input.
Price Each
Mftrs. List No. Order Code 1+ 4 Channel Serial Communications
AOP-12D 343-4916 SIO-4D
8 Channel Relay
RB-8
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 887
Industrial Computing & PLC's
Data Acquisition Cards continued PC/104 Embedded PC
ISA Drivers Windows 3.1 Development Kits
Dynamic Link Libraries PC- compatible 100MHz 4865X
Two Windows 3.1x DLLs (Dynamic Link Libraries) are available.
These allow the functions of the ISA data acquisition and serial com-
munications cards to be used by applications developed using all
the popular Windows 3.1x development tools.
PLC211
Price Each
Mftrs. List No. Order Code 1+
DATACQDLL 343-5003
SERIALDLL 343-5015
Communications Adaptor
2
I C Communications Adaptor CALIBRE ELECTRONICS
Full I2C compatibility
I2 configuration through software
Can be used as a Master of a Slave
Software routines supplied in BASIC
and C
Transparent bus monitor functions A PC-compatible processor board, based on the AMD lan SC400 486SX microcon-
troller. Supplied in Eurocard format (100mm x 160mm) and featuring a 16-bit PC/104
A half length PC expansion card which expansion interface. The board implements a full architecture, using the 100MHz
2
supports the full I C communications pro- processor with power management.
tocol, PC1/O addresses, bus
termination/protection and hardware inter- 16Mbytes of EDO DRAM and 8Mb Flash
rupt line are all link selectable. Drive Support: FDD, HDD, Non-volatile Silicon Disk in Flash
I2 configuration and all other functions are software controllable including the data PC peripherals: Keyobard, mouse, LPT, GPIO
transmission mode and clock speed. Both polled and interrupt driven modes can be 3 x 16550 fast serial ports, 2 x RS232, 1 x RS422/485
supported, marking programming in popular languages easy. Long distance mode can Video: Flat Panel and CRT XVGA, 1Mbytes EDO Video Memory
be supported with the addition of external line drivers (for which a +5V output is pro- Matrix backed Real-time clock and Watchdog
vided) Network support 10 BASE-T Ethernet via RJ-45
Datalight Flash Filing system pre-loaded in bootable flash EPROM. (Bios extension
Software is provided in the form of function libraries in Turbo BASIC and C. These rou-
Allowing EPROM to be used as a bootable read/write drive)
tines implement the basic I2 functions for use with the user's programs. The functions
Available with ROM DOS 6.22 or windows CE operating system pre loaded
available are Adaptor Card Setup, (including SCL clock speed) start and slave address
transmission byte transmission, byte reception, stop transmission and access to a To download technical manual visit www.arcomcontrols.com
Status Register. Example programs are included which illustrate typical uses of the INC281
library functions.
Supplied with manual and software on 55" and 3" disks.
Price Each
PLC131
Order Code 1+ 5+
ELAN - DOS 341-6185
Price Each ELAN - WIN CE 341-6197
Order Code 1+ 3+ 10+
256-109
Compact Industrial PC Enclosure (ACEpc)
For Arcom Elan Processor Board
888 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
DIN Rail or Wall mountable 16-Channel Opto-Isolated Digital Output Module
Up to four PC/104 expansion boards
128 I/O breakouts via two part screw terminals
Integral 24V DC isolated power supply
-20C to +70C operating temperature (with Arcom PC/104 boards).
Full PC Breakout in end panel. (Keyboard, mouse VGA, com 1, 2 + 3, LPTI, net and
Reset)
Meets EN50081-2 Emissions, EN50082-2 Immunity (with Arcom I/O boards and no
keyboard).
Also available 50-way breakout cable for I/O expansion (ACE-CAB50) and Termination
connectors (ACE-TERMPACK)
FOR ELAN-104NC PROCESSOR BOARD
SEE ORDER CODE 341-6185 PAGE 888
INC290
Designed for Industrial automation, Optical isolation of PC from field devices, control
Order Price Each of actuators (outputs).
Code 1+
16 opto-isolated Darlington driver outputs
ACEpc Enclosure 341-6288
18V max load operating voltage
ACE-CAB50 341-6290
40KHz max output frequency
ACE-TERMPACK 341-6306
Catch diode on all outputs for protection when driving inductive loads
Module access LED
To download technical manual visit www.arcomcontrols.com
32-Channel Digital I/O Module INC284
Price Each
Order Code 1+ 3+ 5+
AIM104-OUT16 341-6227
Designed for Digital I/O, Industrial control and monitoring, Interfacing to parallel I/O
devices.
32 digital channels
Bit programmable for input or output
Sink capability 24mA @ 0.45V or source current of 500A @ 2.7V
Module access LED
Define the power-up/reset state
To download technical manual visit www.arcomcontrols.com
INC285 Designed for Industrial on/off control, External contactor driving, Digital input monitor-
26
Price Each ing, contact status monitoring.
Order Code 1+ 3+ 5+ 8-changeover relays
Price Each
Order Code 1+ 3+ 5+
AIM104-RELAY8/IN8 341-6264
Price Each
Order Code 1+ 3+ 5+
AIM104-ADC16/IN8 341-6203
continued
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 889
Industrial Computing & PLC's
To download technical manual visit www.arcomcontrols.com
PC/104 Embedded PC continued INC286
Using Flash memory devices removes the need for EPROM programmers and erasers
during application development. Applications can be stored and run from Flash mem-
ory keeping the battery-backed RAM free for storage data, without wasting valuable
time erasing and programming EPROMs
For distribution your completed application can be copied into a cheaper EPROM pack-
8-bit PC/104 module (16-bit connector fitted to enable bus to be through connect- age and the application may also be 'secured' to stop it being listed or modified. A
ed). K4S 128K is needed to program Flash memory through either variant may run form it.
Can be configured for status, accumulator, frequency, trapezoidal etc. inputs Application program space is very large at 96K
Based around the Hitachi HD63140CP (UPP)
Isolated voltage 1KV DC, field controller
Maximum operating frequency 100KHz K4 Introductory Manuals
Link selectable noise filters (Bandwidth 100Hz) Includes Designing with the Scorpion K4 and The K4 Hardware Reference. Contains over
Board access LED 300 pages of worked examples, explanations and circuits.
I/O mapped on the PC/104 bus
Registered access address space 4-bytes K4 Programmers Reference Manuals
Interrupt generation based on input status changes A 500 page comprehensive programmers manual
All inputs include reverse input protection diodes
Input voltages @ opto-inputs +10V min to +36V max Application Board 1
To download technical manual visit www.arcomcontrols.com Provides the following interfaces for the K4S.
INC289
Serial Port 1: up to 19,200 baud RS232, or RS485 (full or half duplex).
Serial Port 2: up to 1,200 baud RS232.
Price Each Serial Port 3: up to 1,200 baud RS232 Tx only.
Order Code 1+ 3+ 5+ 23 general-purpose digital I/O lines that may be configured for Alpha-numeric LCD,
AIM104-PULSE 341-6276 Keypads, or Parallel Printer.
General-purpose I2C port.
Power requirement: 5V dc, regulated.
Motion Controller Application Board 2
As the application board 1 but with 8 channel, 12-bit ADC, 0 - 5V.
Application Board 3
Provides the following interfaces for the K4S.
Graphics LCD with the provision for EL backlight inverter.
Alpha-numeric LCD.
Serial Port 1: up to 19,200 baud RS232, or RS485 half duplex.
Serial Port 2: up to 1,200 baud RS232, or RS485 half duplex.
Serial Port 3: up to 1,200 baud RS232 transmit only.
16 general purpose digital I/O lines, may be used for keypads up to 8 by 8.
Single-axis DC servo/stepper controller (HCTL-1100) on-board 1A motor drive 16 channel Universal Pulse Processor (UPP).
2/3 ch input for incremental encoder (single/differential) Fitted with a 10 channel 10-bit ADC.
4 opto-isolated inputs: Limit 1, Limit 2, Stop, Home Normal and Long Distance I2C Ports
Selectable motor current limit, programmable digital filter Microwire port.
Control modes: Position, Velocity, Trapezoidal Profile Modem power supply.
Link-selectable IRQ3-15: Module access LED, Motor power LED Power requirement: 8-30V dc.
Interrupt on status change (Limit, Stop, Profile complete).` PLC124A
890 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
K4 Development Board 2 Relay Card
Provides the following interfaces for the K4S. I/O channels: 8 n/o relay contacts
I2C bus channels used: 8 of 128* digital
Serial Port 1: up to 19,200 baud RS232.
Output rating: 6A @ 240V ac
11 general-purpose digital channels.
Size 92 97mm
General-purpose I2C
Power supply: 10-28V dc, 120mA nom.
Universal Pulse Processor (UPP) with 10 cannel bit ADC. See Application Board 3
entry for details of the UPP. Digital Output Card
I/O channels: 16 opto-isolated MOSFETs, n-channel, open drain
Power Supply I2C bus channels used: 8 of 128* digital
Capable of supplying 1.2A @ 12V (unregulated), suitable for powering development On resistance: 0.05
board 2 and the Scorpion controller. Output rating: 4A @ 30V dc
Size: 87 97mm
PCF8574P (204-020)
Digital Input Card
An I2C compatible IC with 8 digital I/O lines.
I/O channels: 16 opto-isolated inputs, 2 banks of 8, +ve or -ve polarity
PCF8583P (403-908) I2C bus channels used: 16 of 128* digital
Optional clock/calendar that plugs directly into the K4S. Input voltage: 24V dc nom.
Size 91 93mm
PCF8591P (396-412)
*The first 64 digital channels are available immediately and the second 64 are available
An I2C compatible IC with 4 analogue inputs (8 bit) and one analogue ouptut (8 bit).
by substituting alternative driver chips in place of those supplied in the card. This is a
PLC124B simple and inexpensive operation.
PLC162
Mftrs. Price Each
List No. Order Code 1+ 5+ 25+ Mftrs Order Price Each
K4S Control module 32K 5520 517-823 List No. Code 1+ 3+ 5+
K4S Control Module 128K 5521 517-835 Relay Card 5620 898-053
K4 Language FLASH 5524 517-847 Digital Output Card 5621 898-065
K4 Introductory Manuals 5514 207-494 Digital Input Card 5622 898-077
K4 Programmers' Manuals 5515 207-500
Application board 1 5522 517-859
Application board 2 5523 517-860
Application board 3 5525 517-872
K4 Development board 2 5503 179-345
Smart Card Readers/Writers
Power Supply 1003 177-543 Contactless smart card read/write modules COMTECH
Price Each
Order Code 1+ 10+ 100+ 250+
I/O Expander IC 204-020.
Clock/calendar IC 403-908.
A/D and D/A IC 396-412.
Price Each
Description Order Code 1+ 5+ 10+
I2C and long distance I2C interface
Fully integrated with K4 language BIS1701D 301-8398
Pluggable screw terminals BIS1702 304-0902
Industry standard signal levels
Up to 20 cards of any type can be daisy chained together continued
LED level indicators
Isolated input and outputs
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 891
Industrial Computing & PLC's
BIS1601A features
Smart Card Readers/Writers continued
Reads and writes ISO7816 E2prom memory cards
Smart card read/write evaluation kit COMTECH ASCII command set
Single +5v power supply
RS232 port 600 - 9600 baud
Operating current during read/write 100mA max.
Quiescent current 25mA
E2prom configuration + user data
Read/writes ST140x memory cards
Powerful command set reduces host software overhead
Suitable for applications in industrial, retail and office environments
Configurable interrupt character on card detection
Dimensions: 100 x 65 x 22mm
Technical data (BIS1601A read/write module)
Parameter min typ max units
Read time (256 bytes) 1000 ms
Write time (256 bytes) 2500 ms
Supply voltage 4.75 5.25 V
Hitag contactless smart card read/write Evaluation Kit
Supply current operating 100 mA
Provides all of the features of the BIS1701D contactless read module in a simple to Baud rate 600 9600 baud
use environment Operating temperature -10 50 C
OC555
Includes a boxed read/write unit with 2 internal LEDs and connectors that bring
out all of the I/O and both the RS232 and RS485 communication ports Price Each
Standard PC RS232 cable and a power supply (UK) are supplied
Order Code 1+ 5+ 10+
To enable the user to access all of the read/write modules powerful features the
unit is supplied with a Win 95 GUI on CD rom and 2 Hitag 1 smartcards 301-8428
OC556
Price Each
Order Code 1+ 5+ 10+
Contact smart card COMTECH
301-8404 ST1402 contact smart card
Fully supported by the BIS1601A read/write unit
Featuring a 256 byte E2prom memory the card uses an I2C bus to communicate the
Contactless smart card COMTECH data to the integrated chip via the pad connector
Compliant with the ISO7816 middle position connector specification and the ISO
Hitag contactless smart card 10536.1 dimensional specification
The contactless smartcard is dimensionally compliant with ISO10536.1 and can Applications include: subscribers card, electronic access, membership cards, elec-
withstand bending and torsional cycles to ISO7816-1 tronic ticketing and data capture
Contains a Hitag 1 chip module and integrated rectangular antenna ST14C02 features
Needs no external power to operate, this is derived from the RF field and will oper-
3.3 to 5.5 volt operation
ate even in a wallet or pocket
2 wire I2C serial interface
Contains a 256 byte E2prom memory and crypto processor unit which can be used
Byte and multibyte write features
for enhanced communication security
Page write to 8 bytes
26 Hitag 1 features
Unique 32 bit factory programmed serial number
Byte random and sequential read
Self timed program cycle
256 byte read/write memory Automatic address increment
Read/write distance up to 700mm (depends on reader antenna) Enhanced ESD and latch up protection
Industrial Computing & PLC's 892
Supports both block and page read/write modes 1 Million erase/write cycles
Manchester encoded data with CRC checking 10 years data retention
Anti-collision encoding for multicard applications
OC562
Encryption unit for secure data communication (depends on reader)
Data retention 10 years Price Each
Operating temperature -20C to +50C
Order Code 1+ 5+ 10+
Protection IP67
301-8430
OC561
Price Each
Order Code 1+ 5+ 10+ Barcode Readers - Fixed
301-8416 Compact Laser Scanner
An ultra compact, high performance and low
cost laser scanner ideal for OEMs and other
Contact smart card read/write module COMTECH applications where reliability and integration
capability are key functions.
892 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Power supply 5V dc +/-5% Output signals Two programmable Input signal 2 digital inputs
digital outputs Output signal 3 digital outputs
Power consumption 2W Programming method Via serial port LED indicators 7 communications status
Light source Visible laser diode Operating modes On line, Serial LEDs
On-line, Keypad 4 membrane keys
Test, Verifier SAT428
Max. depth of field 170mm Laser classification IEC 825 Class 2, Automatic
Aperture angle 52 degrees Case material Die-cast zinc Price Each
Readable codes 22 types incl. 2/5 Operating temp 0 to 40 deg C Mftrs. List No. Order Code 1+
family, Code 39,
Code 93, Code 128,
Controller MX4000-1000 314-1792
EAN/UPC, Codabar
EAN128, Code 49
Multi-label reading Up to 6 different codes in 1045 Fixed CCD Scanner
the same presence sensor
phase Compact and light
Comms. interface Dual serial interface (RS232/RS485) weight
Baud rate 150 to 19,200 bauds Easy mounting, can be used as a presenta-
Input signals One programmable digital input tion scanner
SAT430
Long range 8cm for 15 Mil element width
Resolution 0.125mm
Price Each
Cable selectable interfaces
Mftrs. List No. Order Code 1+ 3+ 5+
Dimensions L80mm x W60 x H29mm
Linear scanner DS2200-1100 314-1743 Durable, ideal for harsh environments
Raster scanner DS2200-1110 314-1755 demanding high depth of field, CCD technol-
DC Converter DC5-2200 314-1767 ogy scanners have no moving mirrors unlike
Power supply PG240-12 314-1779 conventional laser scanners
Advanced data editing and format programming modes supported
OC551
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 893
Industrial Computing & PLC's
Max. resolution 0.12mm Weight 270g
Bar Code Readers - Slot continued Scan rate 36+/-3 scan/s Case material ABS and polycarbonate
Print contrast 15% Cable length 2m
1022 Plastic Barcode Slot Reader ratio (min)
Available in a Reading distance 800mm Laser class Class 2 (IEC 825-1 and DCRH)
Decoder Masked single Operating -10 to 50C
choice of light chip decoder, temp.
sources Red/Infra-red 25MHz Protection Sealed against dust and rain
1022W Plastic housing with TTL data Reading indicators Laser on, good read,
output beeper
1022R Plastic housing with RS232 data Reading angle
output Skew +/-60
1022K Plastic housing with PC key- Pitch 5 to 55C, -5 to 55
Tilt +/-20
board output
SAT432
Reads security card laminated
obscured barcodes, use Infra-red light Mftrs. Order Price Each
source List No. Code 1+ 5+ 10+
Optical:
Light Source: Infra-Red (940nm)/Red (660nm) Scanner DLL6010-M1 314-1809
Resolution: 0.15nm Cable & Accessories
Card Thickness: 0.5 - 1.5mm PS/2 wedge, coiled CAB365 314-1822
Minimum PCS: 0.5 PS/2 wedge, straight CAB321 314-1834
Scanning Speed: 100 - 1000mm/sec
Scanning Position: 11mm from slot bed
RS232 9 pin female, coiled CAB362 314-1846
RS232 9 pin female, straight CAB327 314-1858
Environment:
Temperature (operating) 0 to 40 degree Celsius
Power supply PG5E 314-1860
Temperature (storage) -40 to 60 degree Celsius System manual 90ACC1460 314-1810
Humidity: 5 - 95% (non-condensing)
Electrical:
Voltage: 5V 10% Hand-Held Laser Scanners Cordless
Current (1022W): 35mA (typical), 50mA (maximum)
Current (1022K/R): 50mA (typical), 70mA (maximum) Integral Amplifier
Physical: The DRAGON cordless laser gun allows
Dimension (1022W/K/R): 90.4L x 28.4H x 37.2W (mm) operators to be free of cable while work-
Weight (1022W): 89g (cable not included) ing up to 50m from the base station. It
Weight (1022K): 130g (cable not included) communicates using a low power, licence
Weight (1022R): 144g (cable not included) free radio in the 433MHz band. Equipped
Type Description with bi-directional communications
1022W-IB9F TTL output, Infra-Red light source, DB 9-pin female connector between the base station and the host
1022W-RB9F TTL output, Red light source, DB 9-pin female connector they transmit the code and receive confir-
1022K-ID5Y K-B Wedge for IBM PC AT, Infra-Red light source, DIN-5P Y type cable mation of a correct reading in real time.
1022K-RD5Y K-B Wedge for IBM PC AT, Red light source, DIN-5P Y type connector
1022K-IM6Y K-B Wedge for IBM PC PS2, Infra-Red light source, Mini DIN-6P Y type cable
1022K-RM6Y K-B Wedge for IBM PC PS2, Red light source, Mini DIN-6P Y type connector Supports 2 types of use:
1022R-IB25 RS232, Infra-Red light source, DB-25P female connector Point to point: each gun is associated with its own base station
1022R-RB25 RS232, Red light source, DB-25P female connector Multipoint: many guns (up to 32) transmit data to base station
OC550
Communication is through an integrated multistandard decoder interface (con-
26 Type Order Code 1+
Price Each
5+ 10+
neciton possibility through RS232, Wedge, Pen)
Robust yet light weight (340g)
Point to point and multipoint transmission managed though SW in a single radio
1022W-IB9F 309-7079 channel
1022W-RB9F 309-7080
Industrial Computing & PLC's 894
894 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Cipher Lab Handheld Barcode Scanners 1240 Laser Scanner
Excellent optical performance Visible laser diode at 670nm
Non contact reduces barcode wear 36 scans per second
Built in multi-function decoder allowing 15 different symbologies to be read Typical depth of field 30cm for 15 Mil element width
All interfaces are cable selectable, cable not supplied Minimum print contrast 20% absolute dark/light
Low power consumption reflectance at 670nm
"Good read" indicator and tone bleeper Mechanical durability, 1.5m drop onto a concrete sur-
Available in 67mm/90mm read head width CCD's and Long range laser, allowing a face
wide range of barcode formats to be scanned
Price Each
Type Order Code 1+ 5+ 10+
1067 309-6786 Need an Extra Catalogue?
1090 309-6798
If so, call us on (65) 788 0200
1021 Plus Scanner or e-mail [email protected]
Durable, ideal for demanding
applications, Epos and inventory
control
Low cost
80 scans/sec barcode scan rate
67mm read head width
Depth of field 1-10mm
Ex-stock Products
OC557
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 895
Industrial Computing & PLC's
Barcode Readers - Hand-Held continued Barcode Readers - Pen
Bar Code Scanner Handheld COMTECH Smart Wand Bar Code Reader
CCD Bar code
scanning wand with an integrated
decoder
Automatically decodes 9 bar code sym-
bologies
Low current draw
Medium resolution
Programmable by bar code labels or by
escape sequences
Configurations stored in non-volatile memory CMOS/TTL interface
Metal housing 9 pin male D connector
Bar Code Symbologies Code 39 - standard or extended Codabar
Interleaved 2 of 5 Code 11
Excellent optical performance Low power consumption Code 128 MSI code
Non contact readability reducing bar code wear UPC A, E Code 93
Built in decoder allowing 11 different symbologies EAN 8, 13
Good read indicator and tone bleeper Bar code programmable CMOS/TTL Interface Resolution
60mm and 80mm read heads offering wide read window Output 0 to 5V Medium 0.19mm
CT10U Scanner (Order Code 648-450) Input Up to 15V
OC111
Scanner features:
Full cable format programmability Fast scan rates of 100 scans/sec Price Each
Interchangeable interface quick disconnect Not supplied with cables Mftrs. List No. Order Code 1+ 10+
Enhanced decoder software HBSW-8300 574-247
CT10U Cable Options
CT10U Scanners are not supplied with a cable kit. Cable kits should be chosen from the list below
and purchased in addition to the CT10U Scanner. Low Current Bar Code Wand
Host Hardware Interface
Cable Format IBM PC/AT IBM PS/2 Apple Mac Terminal
Keyboard Wedge 648-395 648-401 648-413
Serial RS232C 648-425 648-425 648-449
Wand emulation 648-437
CT22 Scanner
Scanner features:
Low cost scanner 50 scans/sec scan rate
Dedicated output Non replaceable cables Low continuous current draw High ambient light rejection
Supplied as kit including cables Sealed tip 0.19mm resolution
Scan angle: 0C to 45C typical
26 CT22 Kits
Each scanner has non detachable cables and therefore scanners and cable are supplied in a kit for-
mat. The table below shows cable options available.
HBCSA300 Additional features
Rugged polycarbonate body Dust and water resistant
15kV ESD isolation Digital output-TTL/CMOS compatible
Host Hardware 25kV immunity 5 pin 240 Din connector
Industrial Computing & PLC's 896
896 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
131 Tiny Decoder Magnetic Card Swipe Reader
Reader input port accepts Track Two with RS232 Output
TTL/Wand barcode data output Swipe reader has RS232 interface built
Dual track ISO7811 Clock/Data magnetic slot reader into main body of reader
output Reads track two of any ISO standard
Advanced data editing and format programming card, maximum 40 characters
modes supported Cards can be swiped in either direction
Cable selectable data interfaces, RS232 & PC RS232 serial data output is through a
Keyboard Wedge 2m cable via RS232 connector to a PC
Multiple decoder maybe networked to a single PC Power is taken from the computers ser-
RS232 or keyboard wedge port ial port
Compatible with the FEC HP Wand and Slot reader Any terminal emulation program can be
products, may require connector change used to present data on host computer
For suitable cables see page 309956 Reader transmits fully buffered card
Dimension 82mm (L), 57mm (W), 22mm (H) data as ASCII chatacters
Weight 66g excluding Interface Cable H=41, W=110, D=43 Transmission protocol set as 9600
Power Supply 5VDC 5% baud, 8 data bits, no purity and 1 stop
Current Consumption 34mA, excluding external device bit
Housing ABS/Grey ISO standard 7811
OC565 Weight 250 grammes
Operating temperature -5C to +55C
Price Each Power supply 5Vdc, 25mA maximum
Order Code 1+ 5+ 10+ Connector 9-way Female D-type RS232
309-6919 Card feed speed 100 to 1,500mm/sec
Data output RS232 serial
Read error rate 1/1000 passes maximum
PLC153
Numeric data can be read off the card, upto a maximum of 40 characters
Cards can be swiped in either direction
H=24, W=90, D=24
removed without tools
Mounting holes allow front or reverse 26
ISO standard 7811 mounting to the host device, keyboard etc.
TTL output data is through a 250mm five way cable (supplied)
Weight 40 grammes
Black plastic cover can be removed if required
Allows the reading of track two of any ISO standard magnetic stripe card
ISO Standard 7810, 7811/1-5, 7812, 7813 Data can be read as the card is inserted or withdrawn, TTL data output
Card feed speed 20 to 100cm/s
Two microswitches sense card upon insertion, reading 62% of data track
Service life 300,000 passes minimum
Operation temperature 0 to 45C Three M3 fixing holes provided for easy mounting
Ideal for either logic or physical access control applications
H=35, W=100, D=38
PLC181
ISO standard 7811
Weight 50 grammes
Price Each
Operating temperature -10C to +55C
Mftrs. List No Order Code 1+ 5+ 10+ 25+ Power supply 5Vdc, 25mA maximum
354YR-HNFR4 565-210 PCB circuit Amplifier and F2F decoder
Connector IL-10S3L-(N) (JAE) Socket housing, 10 way
Card feed speed 100 to 1,000mm/Sec
Track read 62% or 46.6mm maximum
Data output TTL logic (Data/Clock pulse)
PLC148
Price Each
Mftrs. List No. Order Code 1+ 5+ 10+ 25+
3S4YR-SBR4-20 737-409
continued
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 897
Industrial Computing & PLC's
Magnetic Strip Readers/Encoders continued Landing Contact Eight Pin Smart Card Connector
Insert Magnetic/IC Card Reader
Reads ISO7811 magnetic stripe cards, choose from 3 different models track
2, track 1 & 2 and track 1, 2 & 3
Cable selectable data interfaces, RS232 & PC Keyboard Wedge
26 Bi-directional card reading supported
Dimension: 150mm (L), 43mm (W), 45m (H) Power Supply: 5VDC 5%
Weight: 180g excluding Interface Cable Current Consumption: 35mA Max.
OC552
Industrial Computing & PLC's 898
Price Each
Mftrs. List No Order Code 1+ 5+ 10+ 25+
V4AF-1J-01V 565-246
898 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Feature Specification
Mechanical:
Body ABS 94VO
Dimensions 60H x 65W x 210L mm
Weight 1.5Kg
Interconnection RS232 cable, RJ45 -> DB9F, 5 feet
Environment:
Operation -10 to 60 degree Celsius
10 to 80% humidity, non condensing
Storage -20 to 70 degree Celsius
10 to 90% humidity, non condensing
OC553
Price Each
Order Code 1+
309-7043
Optional I/F cables for 1023 MSR, 1045 Fixed CCD Scanner &
Tiny Decoders
OC563
Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 899
Industrial Computing & PLC's
Notes
26
Industrial Computing & PLC's 900
900 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST