Modbus Control System Using PLC and SCADA
Modbus Control System Using PLC and SCADA
Abstract
This paper focuses on Modbus control system using PLC and SCADA. Now a days industry needs accurate automation system.
Accuracy enhances by exact reading of data from sources which further uses to control the whole system. The controlling operation
of multi electrical drive is a complex phenomenon and also a necessary one whenever industries are worried. This project
instrument the Mod-bus communication protocol in the drive which is helpful in controlling the particular drive from a group of
several drive with the help of programmable logic controlling (PLC) and supervisory control and data acquisition(SCADA). The
aim of this project is to produce wireless model which will give us the power to control and checking the all system.
Keywords: Programmable Logic Controller (PLC), RS-232 Port, RS-485 Port, Supervisory Control and Data Acquisition
System (SCADA), Modem, Drive, Rj45
________________________________________________________________________________________________________
I. INTRODUCTION
Automation control refers to an area where different control system components are used to operate machines with minimum or
reduced human interposition. Automation is applicable and popular in most of the manufacturing, production industries and is
growing rapidly. To automate any process, programmable logic controllers are widely used.
The controlling operation of multi electric drive is a complex phenomenon and also a necessary whenever industrial are
concerned. This project implements the MODBUS communication protocol in the device which is helpful in controlling the
particular drive from a group of many drive with the help of PLC and SCADA .This project which will give us the powerful
controlling and monitoring the all system.[1]
The paper focuses on Modbus control system using PLC and SCADA. In order to implement this idea, Allen Bradley PLC is
used. AB Micro1000 controllers are economical brick style controllers with the number of drive .It support the following
communication protocols through the embedded RS-232/RS-485 serial port.
The system introduced a system which helps in controlling and monitoring the number of drive. A graphical user Interface called
as human machine interface (HMI) has been developed using supervisory control and data acquisition (SCADA) and the encoding
of the control system has been done using programmable logic control (PLC).Ladder logic is used to build a programmed. A
descriptive study has been incorporated to formulize all factors responsible for the change in valve characteristics. The customer
of the system is able to supply input parameters so as to efficiently control the specific parameters.[3]
III. METHODOLOGY
Hardware
MicroLogix 1100 Programmable Logic Controller.
Drive.
Power Flex 4 drives support the RS485 (DSI) protocol to allow efficient operation with Rockwell Automation peripherals. In
addition, some Modbus functions are supported to allow simple networking. Power Flex 4 drives can be multi-dropped on an
RS485 network using Modbus protocol in RTU mode. For information regarding Device Net or other communication protocols,
refer to the appropriate user manual.[5]
Here system is described the PC are connected to the PLC by Ethernet cable because controlling the parameter by PC. The PLC
are available RS232 port this controlling only one drive so used for RS485 port is controlling the 247 drive. So RS232 converting
the RS485 using Advance interference converter (AIC) .the AIC are available 9 pin input side and 6 pin are output side the upper
pin are vcc (+) supply is connected to the below pin. And last pin are grounded this connected to the upper pin. This two pin no 4
and 5 transmit and receive respectively. Is known as RJ45. This RJ45 or RS485 is connected to the drive. The drive are various
parameter are changed to the controlling the speed of the motor by the drive keyword. And also controlling the speed of the motor
by connected the PC to the PLC. This project are also control by using the Wi-Fi communication (Router).
VI. PROGRAMMING
Fig. 9: Programming
VII. IMPLEMENTATION
VIII. CONCLUSION
This paper discusses the effectiveness of using SCADA to learn the Modbus Rs-232 communication protocol. We have
successfully implemented the different modes of Modbus and also develop a low cost Scada. After the implementation we gather
the data from PLC and SCADA using MODBUS RTU Communication Protocol. Using the low cost SCADA we practically
visualize different graphs as shown in different figures.
REFERENCES
[1] Modbus Application Protocol Specification V1.1b, Modbus-IDA, December 2006, pp. 1-51, [Online] available at http://www.modbus-IDA.org.
[2] PLC SCADA based Distribution Monitoring & Control Multidisciplinary Journal of Research in Engineering and Technology Volume 1, Issue 1 (April 2014)
Pg. 105-110
[3] Home Automation using PLC and SCADA Multidisciplinary Journal of Research in Engineering and Technology, Volume 1, Issue 1 (April 2014) Pg. 111-
118
[4] Pingze ZHANG Changzhou Institute of Mechatronic Technology, Changzhou, Jiangsu, China [email protected]
[5] An overview of continuous monitoring and control system for three phase induction motor based on programmable logical control & SCADA Technology.
volume 4,Issue4, July- August (2013) pp.188-196