IBS Score
IBS Score
IBS Score
2010)
Project Category:
We hereby declare that the information given and the IBS Score submitted herewith is true and complete.
The total IBS Score for the proposed building / project is 70.33
PROJECT DETAILS
Project Name : CADANGAN PEMBANGUNAN BLOK TERES 2 TINGKAT ( UNIT) DI ATAS LOT
Category of Building
Commercial - m2 Others - m2
IBS SCORE for MEREKABENTUK, MEMBINA DAN MENYIAPKAN UNIT RUMAH TERES
Source: Manual for IBS Content Scoring System (IBS Score) - ISBN 983-2724-30-9
IBS Score = Score for Structural Systems + Score for Wall System + Score for Other Simplified Construction
System
50[(Qs/Qst)xFs] + 30[(Qw/Qwt)xFw] + S
2) Structural Systems :
Wall Load Bearing Precast Wall System
Roof Prefabricated steel roof truss
3) Wall System:
Wall area
i) Internal Precast wall panel 45.2 m / unit
ii)External Precast wall panel 71.3 m / unit
Total Wall Area 116.5 m
Part 1 : Structural Systems (a) (b) (a) / (a) =(c) (b) x (c) x 50
Internal Wall
i)In-situ concrete with reusable system formwork 45.2 0.5 39% 3.88
External Wall
i)In-situ concrete with reusable system formwork 71.3 0.5 61% 6.12
USAGE
% USAGE FOR
Elements UNIT THIS PROJECT
IBS SCORE
50%<X<75% 75%<X<100%
IBS Content Score for the project can be calculated using the following formula:
IBS Score for project = {IBS Score of building x Qst (building) / Qst(project)}
Therefore, the IBS score for the whole of the development project is 70.33