Specification sheet

VTA28-G5

Description Features
The VTA28-Series benefits from years of technical Coolpac Integrated Design - Products are supplied
complete with cooling package and air cleaner kit for a
development and improvement to bring customers
complete power package. Each component has been
an innovative and future proof diesel engine that specifically developed and rigorously tested for G-Drive
keeps pace with ever changing generator set products, ensuring high performance, durability and
requirements. reliability.
Recognised globally for its performance under Aftercooled Two large capacity aftercoolers result
even the most severe climatic conditions, the in cooler, denser intake air for more efficient
VTA28-Series is widely acknowledged as the most combustion and reduced internal stresses for longer
robust and cost-effective diesel engine in its life.
power range for the generator set market. Cylinder Block Alloy cast iron with removable wet
liners. Cross bolt support to main bearing cap provides
extra strength and stability.
Fuel System Cummins PT self-adjusting system.
Integral dual flyweight governor provides overspeed
protection independent of main governor.
Turbocharger Two Cummins Turbo Technologies
(CTT) turbochargers mounted at top of engine.
Turbocharging provides more power, improved fuel
economy, altitude compensation and lower smoke.
Service and Support - G-Drive products are backed
by an uncompromising level of technical support and
after sales service, delivered through a world class
service network.

Codes and standards


This engine has been designed in
This engine has been built to facilities certified to ISO9001 and
comply with CE certification. manufactured in facilities certified to
ISO9001 or ISO9002.

1500 rpm (50 Hz Ratings)


Gross Engine Output Net Engine Output Typical Generator Set Output
Standby
Standby Prime Base Standby Prime Base Prime (PRP) Base (COP)
(ESP)
kWm/BHP kWm/BHP kWe kVA kWe kVA kWe kVA
612/820 560/750 492/660 584/783 538/721 470/630 560 700 509 636 445 556

1800 rpm (60 Hz Ratings)


Gross Engine Output Net Engine Output Typical Generator Set Output
Standby
Standby Prime Base Standby Prime Base Prime (PRP) Base (COP)
(ESP)
kWm/BHP kWm/BHP kWe kVA kWe kVA kWe kVA
671/900 608/815 504/675 630/845 574/770 470/630 600 750 545 681 442 552

Our energy working for you.


www.cumminsgdrive.com
2014Cummins G-Drive EnginesSpecifications Subject to Change Without NoticeCummins is a registered trademark of Cummins Inc.
GDSS134a (7/14)
General Engine Data Ratings Definitions
4 cycle, in line, Turbocharged and Emergency Standby Power (ESP):
Type
after-cooled Applicable for supplying power to varying electrical load for the
Bore, mm 139.7 duration of power interruption of a reliable utility source.
Stroke, mm 152.4 Emergency Standby Power (ESP) is in accordance with ISO 8528.
Displacement, Litre 28 Fuel Stop power in accordance with ISO 3046, AS 2789, DIN
Cylinder Block Cast iron, 40V 12 cylinder 6271 and BS 5514.
Battery Charging Alternator 55A
Starting Voltage 24V Limited-Time Running Power (LTP):
Fuel System Direct injection Applicable for supplying power to a constant electrical load
Spin on fuel filters with water for limited hours. Limited-Time Running Power (LTP) is in
Fuel Filter
separator accordance with ISO 8528.
Lube Oil Filter Type(s) Spin on full flow filter
Lube Oil Capacity (l) 83 Prime Power (PRP):
Flywheel Dimensions SAE 0 Applicable for supplying power to varying electrical load for
unlimited hours. Prime Power (PRP) is in accordance with
Coolpac Performance Data ISO 8528. Ten percent overload capability is available in
accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514.
Cooling System Design Jacket Water After Cooled
Coolant Ratio 50% ethylene glycol; 50% water Base Load (Continuous) Power (COP):
Coolant Capacity (I) 126 Applicable for supplying power continuously to a constant
Limiting Ambient Temp.(C)** 50.0 (50Hz) electrical load for unlimited hours. Continuous Power (COP)
Fan Power (kWm) 19.6 (50Hz) in accordance with ISO 8528, ISO 3046, AS 2789, DIN6271
Cooling system air flow (m3/s)** 12.5 (50Hz) and BS 5514.
Dry replaceable element with
Air Cleaner Type
restriction indicator
** @ 13 m m H2O

Weight and Dimensions


Length Width Height Weight (dry)
mm mm mm kg
2371 1457 2092 3215

Fuel Consumption 1500 (50 Hz) Fuel Consumption 1800 (60 Hz)
% kWm BHP L/ph US gal/ph % kWm BHP L/ph US gal/ph
Standby Power Standby Power
100 612 820 154 40.8 100 671 900 173 45.7
Prime Power Prime Power
100 560 750 140 37 100 608 815 154 40.7
75 420 563 104 27.5 75 456 611 118 31.2
50 280 375 73 19.3 50 304 408 84 22.2
25 140 188 43 11.3 25 152 204 50 13.1
Continuous Power Continuous Power
100 492 660 122 32.1 100 504 675 128 33.9

Cummins G-Drive Engines


Asia Pacific Europe, CIS, Middle Latin America Mexico North America
10 Toh Guan Road East and Africa Rua Jati, 310, Cumbica Cummins S. de R.L. de C.V. 1400 73rd Avenue N.E.
#07-01 Manston Park Columbus Ave Guarulhos, SP 07180-900 Eje 122 No. 200 Zona Industrial Minneapolis, MN 55432
TT International Tradepark Manston Ramsgate Brazil San Luis Potos, S.L.P. 78090 USA
Singapore 608838 Kent CT12 5BF. UK Phone 55 11 2186 4552 Mexico Phone 1 763 574 5000
Phone 65 6417 2388 Phone 44 1843 255000 Fax 55 11 2186 4729 Phone 52 444 870 6700 Toll-free 1 877 769 7669
Fax 65 6417 2399 Fax 44 1843 255902 Fax 52 444 870 6811 Fax 1 763 574 5298

Our energy working for you.


www.cumminsgdrive.com
2014Cummins G-Drive EnginesSpecifications Subject to Change Without NoticeCummins is a registered trademark of Cummins Inc.
GDSS134a (7/14)

You might also like