SPECIFICATIONS
Material..................................................Stainless Steel, Aluminum
WHITL
WH
WHITLOCK
ITLOC
OCK
K
1-800-337-3412
-800-337-3412
w
www.noflo.com
ww.noflo.com
U.S. PAT. NO. 5,835,372
0 0
R
1
Switch RaTing........................................................2.5VA/240 VDC
INSTRU
INS
INSTRUMENT
TRUMEN
MENTT
ODESSA, TX USA
CYCLE INDICATION MODEL LED
LED
Factory Sealed RATED 2.5V
2.
2.5VA
5VA
A / 2240VDC
40VD
40 VDC
C
Epoxy Encapsulated.......................UL LISTED EL-CAST VFR 641
R
II 2G EEx md IIC T5
CE SERIAL #
00 05 06
Alarm/Shutdown........................ Factory default for 2 minute alarm
C US
Cl I; Zone 1; Ex md IIC T4 P/N
186200 Cl I; Div 1; Grps. A,B,C,D;T4 0344
ALARM 2-M IN
KEMA 00ATEX1090 X Amb. -40 C...+80C
RED-Open Loop ORANGE-Closed Loop GRN-Ground Power......................................Field Replaceable - Lithium Battery
Battery........................................................................ P/N 000505
DNFT-LED
Alternate Battery........................................Radio Shack 960-0418
Divider Block Application............Dropsa/Lincoln/SBCO/Lubriquip
Warranty.........................................................................2.5 Years
MONITORS MOVEMENT OF DIVIDER
BLOCK PISTON FOR DEPENDABLE
TIMED SHUTDOWN PROTECTION
RATINGS
US
II 2G EEx md IIC T5
Cl I; Zone 1; Ex md IIC T4
186200 Cl I; Div 1; Grps. A,B,C,D;T4 0344
CE
KEMA 00ATEX1090 X Amb. -40 C...+80C
INSTALLS DIRECTLY TO DIVIDER
VALVE
DESCRIPTION
NOT AFFECTED BY TEMPERATURE The DNFT-LED is a totally enclosed electronic device ,combining the
OR OIL VISCOSITY latest technology in microprocessor and transist or components for
detectingSlow-FlowandNo-Flowofdividerblocklubricationsystems. The
REQUIRES NO EXTERNAL POWER DNFT incorporates an oscillating crystal to accurately monitor the
cycle time of the lubrication system to enable precision timed shutdown
LED INDICATOR - CYCLE INDICATION
capability. The magnet assembly and control housing mount directly to
thedividervalvetobecomeanintegralpartofthelubrication system. DNFT
operates on a field replaceable lithium battery. If battery voltage drops
DEDICATED SWITCH CLOSURE TO
below normal operating levels, the DNFT goes into alarm mode and the
MONITOR EACH DIVIDER VALVE
unit cannot be restarted. LED models utilize an LED to indicate each
CYCLE (PS OPTION)
cycle of the divider valve. This enables the operato r to easily set and
monitor lubrication rates.
FIELD REPLACEABLE BATTERY
OPERATION
Lubricant flow through the divider valve assembly forces the pistons
to cycle back and forth causing a lateral movement o f a magnet
linked to the piston. Movement is monitored by the microprocessor
Distributed by: which resets the timer, lightsthe LED, and allows the unit to continue
operation, this indicates one complete cycle of the lubrication
system. The microprocessor must receive this cycle in a
predetermined time or a shut down will occur. The DNFT will
automatically reset alarm circuit when normal operation of divide
valve resumes.
506LIT LED-WI-2
DNFT
DNFT
WHIT
WHITLOCK
ITL
LOCK
WHITLOCK INSTRUMENT
1-800-337-3412
-800-337-3412
w
www.noflo.com
06.05.01
ww.noflo.com
1300 N. Texas
R
Odessa, TX 79761
432.3373412 Fax 432.335.5926
1
DIGITAL NO-FLOW TIMER INS
IN
INSTRUMENT
STR
TRUUMENT
U.S. PAT. NO. 5,835,372 1.800.337.3412 www.noflo.com ODESSA, TX USA
1. Loosen all Allen head set screws (A) on DNFT-LED (B) and remove magnet housing (C). Do not remove magnet, spring, or
spacer from magnet housing.
2. Remove piston enclosure plug (D) from end of divider valve where DNFT-LED will be installed. The DNFT-LED does not
have to be installed on the top divider valve. It may be installed on any convenient divider valve, top to bottom. (Notice:Do not
install DNFT-LED on Lincoln divider valves with cycle indicator pins or any Dropsa divider valve less than SMX 16.)
3. Be sure O-ring or metal gasket (F) is in place on magnet housing (C). Screw magnet housing (C) into end of divider valve
(E). Torque to 15 foot pounds max.
4. Slide DNFT-LED (B) all the way onto hex of magnet housing (C). Tighten set screws on hex of magnet housing. Torque 25
inch pounds max.
5. The LCD (G) on the DNFT-LED indicates total divider valve cycles and changes with each cycle. This enables operator to
adjust the lubricator pump for correct cycle time and oil consumption recommended by compressor manufacturer. If the number
on the LCD (G) does not change with compressor running or by manually pumping oil into divider valve, the DNFT-LED must
be adjusted.
6. Before adjusting DNFT-LED, divider valve must be cycling. This can be achieved with the compressor running or by
manually pumping oil through the divider valve assembly with a hand priming pump.
7. Adjustment is made by sliding the DNFT-LED (B) all the way on the hex of the magnet housing (C). Tighten set screws on
hex of the magnet housing to 25 inch pounds max. Check for LCD (G) change to confirm correct adjustment. If LCD (G) does
not change with divider valve cycling, adjust the DNFT-LED back in 1/16" increments. Correct adjustment of the DNFT-LED is
confirmed by number change on the LCD (G).
8. All conduit and connections should be appropriate for area classification. Notice: Conduit and fittings must be supported to
avoid bending magnet housing.
9. After installing magnet assembly and pre-compressor start-up, it is absolutely necessary to purge all air from divider
block lubrication system. This can easily be accomplished with a lubrication system purge gun.
10.DNFT-LED must be installed with correct magnet assembly for each divider valve manufacturer.
Lincoln-7/16"-20 extended nose with O- ring Dropsa-1/4 BSP with special metal spacer
Trabon-1994 or earlier 7/16"-20 with metal crush gasket Trabon-1995 and later 7/16"-20 with O-ring
Notice: When installing more than one DNFT, each DNFT must be wired to a separate alarm circuit
of the control panel, annunciator or PLC to simplify troubleshooting the lubrication system and DNFT.
O-RING OR ALLEN HEAD
METAL GASKET DNFT MAGNET SET SCREW S(2) #22 AWG 18" LEADS (7)
INTERNAL VIEW OF (F) (B) (I)
HOUSING (A) SPACER SPRING
DIVIDER VALVE
(E) (C)
W
WHITLOCK
HIT
ITL
LOCK
RED
1-800-337-3412
-800-337-3412
w
www.noflo.com
ww.noflo.com
INS
IN
INSTRUMENT
STRUMENT
ODESSA, TX USA GREEN ORANGE
CYCLE INDICATION L
LED
ED ORANGE
MODEL
22.5VA
.5V
.5 VA / 2240VDC
40VDC
ORANGE
Factory Sealed RATED
ORANGE
24S C
R
US
II 2G EEx m IIC T5
Cl I; Zone 1; Ex md IIC T4
CE SERIAL #
P/N 000506
LED
186200 Cl I; Div 1; Grps. A,B,C,D;T4 0344
ALARM 2-MIN
KEMA 00ATEX1090 X Amb. -40 C...+80C
RED-Open Loop ORANGE-Closed Loop GRN-Ground
MAGNET FIELD REPLACEABLE
BATTERY
(H) P/N:000505
DNFT-LED O-RING
24S PIST ON ENCLOSURE PLUG (F)
(D)
1/2 PIPE PLUG
CONT ROL HOUSIN G POLARIZED CONNECTOR
CAUTION: DISCONNECT ALL WIRING PRIOR TO WELDING ON COMPRESSOR OR SKID.
WIRING LEGEND
DNFT-LED RED..................................NORMALLY OPEN OPERATION
ORANGE ....................NORMALLY CLOSED OPERATION
GREEN......................................................CASE GROUND
ORANGE
ORANGE
INSULATE
FROM CONTACT ORANGE
DNFT
DNFT
06.05.01
1-800-337-3412
-800-337-3412
w
www.noflo.com
ww.noflo.com
1300 N. Texas
Odessa, TX 79761
R
432.3373412 Fax 432.335.5926
1
DIGITAL NO-FLOW TIMER 1.800.337.3412 www.noflo.com
INST
IN
INSTRUMENT
STRU
RUMMEN
ENTT
U.S. PAT. NO. 5,835,372 ODESSA, TX USA
TROUBLESHOOTING DNFT-LED
NOTICE: WHEN MORE THAN ONE DNFT IS INSTALLED ON THE COMPRESSOR OR ENGINE, EACH DNFT MUST BE WIRED TO A SEPARA TE ALARM
CIRCUIT ON THE CONTROL PANEL, ANNUNCIATOR OR PLC T O SIMPLIFY TROUBLESHOOTING THE LUBRICATION SYSTEM AND DNFT.
SPRING
Loosen set screws, remove DNFT from magnet housing. Remove magnet
MAGNET SPACER
B. Spring or Magnet is assembly from divider valve. Remove magnet, spacer and spring. Check
Broken in Magnet components for damage. Replace damaged spring and/or magnet and install on
Assembly divider valve. If necessary, adjust DNFT , check for LED blink. Purge air from
MAGNET HOUSING (HEX) system with lubrication system purge gun.
Remove the battery from the DNFT per the attached instructions. Replace the
C. Low Battery voltage battery if the voltage is below 2.5 volts using a factory recommended replacement
battery.
Loosen set screws, remove DNFT from magnet housing. Check for damaged or
D. Bent Magnet Housing bent magnet housing. Remove magnet assembly from divider valve. Replace
STRAIG HT OK !
magnet housing, magnet, spring and spacer. Re-install DNFT on magnet
BENT REPLA CE !
housing. If necessary, adjust DNFT , check for LED blink. Purge air from
system with lubrication system purge gun.
w
www.noflo.com
RED
ww.noflo.com
INS
IN
INSTRUMENT
STRUMENT
L
LED
ED
ORANGE
GREEN
1994 or Earlier
22.5VA
.5V
.5 VA / 2240VDC
40VDC
24S C
R
US
Factory Sealed
II 2G EEx m IIC T5
Cl I; Zone 1; Ex md IIC T4
CE SERIAL #
RATED
000506
7/16"-20
P/N
186200 Cl I; Div 1; Grps. A,B,C,D;T4 0344
2-MIN
KEMA 00ATEX1090 X Amb. -40 C...+80C
ALARM
DNFT
DNFT
W
WHITLOCK
HIT
ITL
LOCK 06.05.01
1-800-337-3412
-800-337-3412
w
www.noflo.com
1300 N. Texas
ww.noflo.com
Odessa, TX 79761
R 432.3373412 Fax 432.335.5926
1
DIGITAL NO-FLOW TIMER 1.800.337.3412 www.noflo.com INS
IN
INSTRUMENT
STRUMENT
U.S. PAT. NO. 5,835,372 ODESSA, TX USA
LED
MAGN ET FIELD REPLACEABLE
BATTERY
(H) P/N: 000505
O-RI NG
(F)
1/2 PIPE PL UG
CONTROL HOUSING POLA RIZED CONN ECTO R
(B)
3. Remove the battery from the DNFT and disconnect from the polarized connector.
6. Verify the DNFT is working by pre-lubing the system and check for LCD number change.