Sewage Pumping Handbook
Sewage Pumping Handbook
Sewage Pumping Handbook
www.first4seals.com
introduction
f4s10 systems
The f4s10 system is a range of barrier fluid systems to cover most applications, offering fast and problem-free installation on-site. These are supplied
with all necessary components and fittings. Where applicable an easy to fit optional polyamide hose kit is available.
vessel code
The f4s10 is designed and manufactured in accordance with ASME VIII Div1 (not stamped) and
complies with PED97/23/EC.
BARRIER & BUFFER FLUID SYSTEMS FOR USE WITH DOUBLE MECHANICAL SEALS
first4seals supplies an extensive range of barrier and buffer fluid systems for use with double mechanical seals.
Wherever possible first4seals prefers to supply both the seal and the system. In addition the company will suggest
suitable barrier or buffer fluids for most applications, based on extensive field experience.
first4seals accepts no responsibility for any problem associated with system design, installation, operation, or the
use of an unsuitable barrier or buffer fluid, where the fluid, seal or any part of the system have not been specified
and/or supplied by first4seals.
2
f4s10 range
thermosyphon seal support systems
Water retention systems are filled and pressurised by direct connection to a clean site water supply, where water is an acceptable barrier fluid, and a suitable
supply is available.
pressure systems
f4s10 - buffer system
Comprises vessel and sight glass only. May be used unpressurised to provide cooling on medium temperature applications, to prevent crystallisation of
aqueous solutions, or to provide protection from dry-running damage.
f4s10 - basic pressure system
A basic system which includes a relief valve and an air/N2 regulator to allow pressurisation from a factory supply. Pressurising to a minimum 1 bar (14.5
psi) above stuffing box pressure prevents any abrasive particles in the product from damaging the seal faces.
f4s10 - pressure system options
As basic but with the addition of a ball valve to simplify topping up the fluid level. Cooling coil & finned tubing intended for hot applications where high
cooling capacity is needed.
Finned tubing aids heat dissipation and improves thermosyphoning. Stainless steel or copper-nickel alloy pipework is recommended (not supplied as
standard). Additional cooling capacity can be achieved using the optional integral cooling coil.
Low level and pressure sensors for applications requiring early warning of barrier fluid system problems.
3
f4s10 range
thermosyphon seal support systems
vessel
sight glass
MIN FLUID
LEVEL
12mm (1/2)
hose kit
(optional)
4
f4s10 range
thermosyphon seal support systems
relief valve
air/N2 supply
regulator
pressure gauge
vessel
sight glass
MIN FLUID
LEVEL
12mm (1/2)
hose kit
(optional)
5
f4s10 range
thermosyphon seal support systems
low pressure
switch
relief valve
level switch
(optional)
pressure gauge air/N2 supply
regulator
pressure gauge
vessel
sight glass
MIN FLUID
3-way valve LEVEL
(optional)
drain hose
ball valve
(optional)
cooling coil
(optional)
drain hose
finned tubing
(optional)
2 x 1/2 compression
fittings supplied.
tube not supplied
as standard
(stainless steel or
copper-nickel alloy
piping recommended)
6
f4s10 range
thermosyphon seal support systems
spring
loaded
non-return
valve
sight glass
MIN FLUID
vessel LEVEL
12mm (1/2)
hose kit
(optional)
7
f4s10 range
thermosyphon seal support systems
flow
water supply indicator
regulator
(optional)
spring
loaded
non-return
valve
pressure
gauge
vessel
MIN FLUID
3-way valve
(optional)
cooling coil
(optional)
ball
valve
(optional)
drain hose
finned tubing
(optional)
2 x 1/2 compression
fittings supplied.
tube not supplied
as standard
(stainless steel or
copper-nickel alloy
piping recommended)
8
f4s10 range
thermosyphon seal support systems
feature descriptions
11
6 9
2
8
12
5 10
14 13
3
7
9
f4s10 range
thermosyphon seal support systems
WELD
SEAM
(51mm)
2.000
(87mm)
14.360 (365mm)
(75mm)
3.432
2.953
2.250
(57mm)
4.000
1.930 (102mm)
(87mm)
3.432
(49mm)
4 EA
MOUNTING
HOLES 7/16
(11mm) DIA.
2 PORTS
TAPPED
1/4
1/8 (3mm)
THICK PLATE
FOR MOUNTING
1.250 (32mm) BRACKETS
TYPICAL BOSS DIA 2 OFF ADDITIONAL PORTS ON
COOLING COIL VESSEL OPTION
When correctly installed, a thermosyphon barrier fluid system is simple, effective and highly reliable. These guidelines will help ensure trouble free
installation and operation.
pipework
Use 1/2" (12mm) pipe or larger.
fittings
Do not use fittings with overly restricted bores, contact supplier for correct specification.
direction of flow
In an ideal system the ports on the seal should be vertical and the hot fluid will emerge from the uppermost seal connection, which is then piped up to
the return (side) connection on the reservoir. In practice the ports may end up being horizontal, but this should not pose a problem if the seal is correctly
installed.
When the system is first run, check the direction of flow - i.e. which pipe gets hot. The hot pipe must go to the return (side) connection on the reservoir,
or flow may cease after a short while. If the flow is the wrong way round, reverse the connections at seal or vessel. This is, of course, only valid where
the ports are horizontal. If the ports are vertical, we would recommend that the seal is re-installed. It should be noted that even a slight concentric
misalignment would cause the barrier fluid to flow in the opposite direction.
commissioning checks
Fill and pressurise the system, check for and eliminate any leaks.
Run the pump (or mixer etc.), and check which pipe gets hot. Reverse pipe connections if necessary on horizontal porting - reset seal on vertical porting.
Run the system normally for several hours to reach equilibrium temperatures, periodically checking seal inlet and outlet temperatures. The riser
temperature must not exceed 70C (158F), and also the feed/riser temperature difference should not exceed 25C (77F). Above 70C (158F) site safety
code may dictate guarding.
With pressure systems, check the fluid level does not fall during operation.
10
f4s10 range
thermosyphon seal support systems
horizontal distance
between seal &
vessel should be
3' (1m) maximum
level MUST be
above minimum level MIN FLUID
LEVEL
should be 2' (0.7m) minimum
vertical distance between
seal & vessel
no sags in riser
riser (hot)
no sags from
seal port
feed line
prime seal first for (cold)
vertical shafts
11
f4s10
range
first4seals plc, mount street, bradford, west yorkshire. bd3 9sn united kingdom
Tel: +44 (0) 1274 720775 Fax: +44 (0) 1274 729022
email: [email protected] - web: www.first4seals.com
Copyright 2011 first4seals plc
DOC / F4S 5248 05/2011
Reference Issue L - UK/US - F4S10 - 01