Maintenance & Trouble shooting
Xian/GuiLin NEC
Aug. 2008
NEC-MIC-0807506 Ver.2.1
Training book Pasolink maintenance
CONTENTS
NEC-MIC-0807506 2 Ver.2.1
Training book Pasolink maintenance
In door:
Grounding cable connection
E1 cable connection
Power cable connection
Outdoor:
Grounding cable connection
IF connector water proof (Outdoor)
The polarization of Antenna
NEC-MIC-0807506 3 Ver.2.1
Training book Pasolink maintenance
Example 1
IF connector waterproof
OK Wrong
Water leakage will affect High
BER or equipment damaged
NEC-MIC-0807506 4 Ver.2.1
Training book Pasolink maintenance
Example 2
OK Wrong
Poor grounding will affect traffic
error or ODU damaged
NEC-MIC-0807506 5 Ver.2.1
Training book Pasolink maintenance
Example 3
E1 cable connection
OK Not good
Poor cabling will affect
traffic error
NEC-MIC-0807506 6 Ver.2.1
Training book Pasolink maintenance
1+0 System
1+1 HS (Hot standby)
1+1 HS/SD (Hot standby/Space diversity)
1+1 Twin path (Frequency diversity)
NEC-MIC-0807506 7 Ver.2.1
Training book Pasolink maintenance
1+0 system
NEC-MIC-0807506 8 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 9 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 10 Ver.2.1
Training book Pasolink maintenance
1+1 HS/SD
1+1 HS/SD
NEC-MIC-0807506 12 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 13 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 14 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 15 Ver.2.1
Training book Pasolink maintenance
LCT connection
LCT menus
NEC-MIC-0807506 16 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 17 Ver.2.1
Training book Pasolink maintenance
Remote configuring/monitoring is
not possible when the PM card is
mounted or during HBER alarm
condition.
NEC-MIC-0807506 18 Ver.2.1
Training book Pasolink maintenance
LCT cable
You can make LCT cable on site if you dont have it.
Of cause, you should prepare the material from electronic market
first.
NEC-MIC-0807506 19 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 20 Ver.2.1
Training book Pasolink maintenance
Press the CTRL and D keys at the same Setting: Local configuration of IDU and ODU
time
Maintenance: IDU and ODU maintenance functions
Password :(Enter)
Monitoring: Pasolink Alarm / Status Monitoring
Change Password? (No:0/Yes:1) :0 function
NEC-MIC-0807506 21 Ver.2.1
Training book Pasolink maintenance
MAINTENANCE
1. Setting Maintenance
2. Maintenance 1. MAINT (NORM)
3. Monitoring 2. FE loop back ctrl 1-16 (ctrl:---- ---- ---- ----)
4. Exit (ans :---- ---- ---- ----)
Select Function No: 3. NE loop back ctrl 1-16 (ctrl:---- ---- ---- ----)
(ans :---- ---- ---- ----)
4. BER ALM >> AIS (on)
To display the Maintenance menu,
press [2] and [Enter] from the LCT 5. CW (off)
main menu. 6. Power mute1 (off)
The Maintenance Menu is used to carry out 7. Power mute2 (off)
the following functions. 8. TX SW ctrl (AUTO)
Maintenance ON/OFF 9. RX SW ctrl (AUTO)
Far end loop back
10. ATPC manual ctrl (off)
Near end loop back
Transmit CW carrier
00. Menu
Stop Transmission (Mute) 99. Exit
BER AIS insertion ON/OFF
MAINT (Normal:0 / MAINT:1) : 0
TX and RX manual switching(1+1)
When the maintenance mode is on, or any of the maintenance
Manual ATPC control control items are on, the front panel MAINT LED (amber)
lights.
NEC-MIC-0807506 22 Ver.2.1
Training book Pasolink maintenance
MONITORING
1. Setting Monitoring
Monitoring voltage
2. Maintenance 1. Monitoring voltage
TX power1 :4.10V (< -5dB)
3. Monitoring 2. Monitoring voltage
RX level1 :2.37V ( -61dBm)
4. Exit (continuous mode)
TX power2 :*.**
Select Function No: 3. Alarm/Status
RX level2 :*.**
4. Inventory
00. Menu
Press [3] and [Enter] from the DATA (Monitoring voltages)
LCT main Menu to display
2. Monitoring voltage (continuous Measured input / TX output
the Monitoring menu.
mode) Time stamp (1min:0 RF signal levels are
The monitoring menu is used to / 1sec:1):1 displayed. The metering
monitor the equipment for Press any key to start... range for each
preventive maintenance measurement is given
purposes. This menu in the table above. TX
provides monitoring of the output power is given as
METER READING OF ODU PARAMETERS the detector voltage and
Transmit and Receive signal
levels. Equipment status and Transmitter Power 0 to 4.6 V DC attenuation used in dB.
alarm can also be monitored Receiving Level 0.8 to 4.4V DC RX signal level is given
from this menu. Inventory list (Depend on the Transmitter Power and the as AGC voltage and in
provides details of the Receiving Signal level ) dBm
modules in the equipment
NEC-MIC-0807506 23 Ver.2.1
Training book Pasolink maintenance
ALARM/STATUS MONITORING
Monitoring of alarm/status 1/2
Monitoring
IDU
1. Monitoring voltage INPUT LOSS 1-16 (alarm:---- ---- ---- ----)
2. Monitoring voltage CHANNEL USAGE ERROR 1-16 (alarm:---- ---- ---- ---
(continuous mode) Press 3 and ENTER -)
3. Alarm/Status AIS RCVD 1-16 (alarm:---- ---- ---- ----)
4. Inventory AIS SEND 1-16 (alarm:---- ---- ---- ----)
OUTPUT LOSS 1-16 (alarm:---- ---- ---- ----)
00. Menu
TX CLK LOSS (alarm:-/-)
Select item No. : 3
RX CLK LOSS (alarm:-/-)
3. Monitoring of alarm/status 2/2 FSYNC ALM (alarm:-/-)
MOD ALM (alarm:-/-) HIGH BER ALM ( alarm:-/-)
DEM ALM (alarm:-/-) LOW BER ALM (alarm:-/-)
OPR ALM ) (alarm:-/-) BER ALM (alarm:-/-)
MDP CPU ALM (alarm:-/*) Press any key to continue
ODU Monitoring of alarm/status 2/2
TX PWR ALM (alarm:-/-)
RX LEV ALM ) (alarm:-/-)
APC1 ALM (alarm:-/-) The IDU and ODU alarms and status
APC2 ALM (alarm:-/-) information can be viewed form this
IF INPUT ALM (alarm:-/-) menu item. Alarm condition is
MUTE (on) indicated by * and normal
TX/RX FREQ CH (1ch ) condition by -.
NEC-MIC-0807506 24 Ver.2.1
Training book Pasolink maintenance
ALARMS-1
NEC-MIC-0807506 25 Ver.2.1
Training book Pasolink maintenance
ALARMS-2
MOD ALM
WS output loss
Modulator 850 MHz PLL oscillator loop unlock
In the optional WS interface card, Receive WS condition.
signal not detected from the demodulator. DEM ALM
TX CLK loss RX carrier not synchronized or lost.
Loss of TX clock, in the 2 MB interface. OPR ALM
RX CLK loss Communication error between ODU and IDU
Loss of RX clock in the 2 MB interface. ODU ALARMS
FSYNC ALM TX Power ALM
Loss of RX frame synchronization at the RX DPU. Transmitter output power decreased by 3 to 5 dB
HIGH BER ALM RX Level ALM
Receive level below squelch level
When the receive BER is > 10-3
APC1 ALM
LOW BER ALM ODU 1st local oscillator APC unlock alarm
When the receive BER is > 10-6 APC2 ALM
BER ALM ODU 2st local oscillator APC unlock alarm
BER alarm point for inserting AIS. Alarm trigger
point can be selectable from (10-3, 10-4, 10-5
and 10-6)
NEC-MIC-0807506 26 Ver.2.1
Training book Pasolink maintenance
AnnexLCTMENUS(ALL)
1.Bit rate (16x2MB) INPUT LOSS AIS RCVD
TX power ctrl
1. ATPC/MTPC
2. AIS RCVD alarm/status AIS SEND OUTPUT LOSS
2. MTPC TX power
3. AIS SEND alarm/status WS INPUT LOSS WS AIS
3. ATPC TX power range RCVD WS AIS SEND
4. TX/RX frequency
4. ODU ALM mode WS OUTPUT LOSS LAN
Setting
5. TX power ctrl
5. RX threshold INTFC ALM TX CLK LOSS
6. Main channel usage 1-16
00. Menu RX CLK LOSS FSYNC
7. BER alarm threshold ALM
99. Exit
Alarm Table
8. Frame ID 1.Thoughtput HIGH BER ALM LOW BER
9. WS channel usage ALM BER ALM
Port setting
2.Mode
Password: 10. DSC1 MOD ALM
LAN setting
3.Flow ctrl
Next Item
11. DSC2 1. Port1 setting DEM ALM
Password Change: 12. DEM invert
1. System configuration
2. Port2 setting 4.Framing OPR ALM
2. LAN setting
13. Alarm table 3. Channel usage error 3. FE link down 5.CAS TX PWR ALM RX LEV
14. Next items 00. Menu 00. Menu ALM APC 1 ALM
6.CRC
00. Menu 99. Exit 99. Exit APC2 ALM
7.Collion Report
99. Exit IF INPUT ALM MAINT
00.Menu TX SEL
1.Setting 1. MAINT
Maintenance
99.Exit RX S EL
2. FE loop back ctrl 1-16
2.Maintenance MDP CPU ALM
3. NE loop back ctrl 1-16
(1+0) 4. BER ALM >> AIS
3.Monitoring TX power :*.** INPUT LOSS 1-16
5. CW
RX level :*.** CHANNEL USAGE ERROR 1-16
6. Power mute
IDU
4.Exit 7. ATPC manual ctrl
AIS RCVD 1-16
AIS SEND 1-16
00. Menu
OUTPUT LOSS 1-16
99. Exit
LAN INTFC ALM
Maintenance
ODU
Shift frequency MUTE
4. Inventory MDP CPU ALM
Serial number TX FREQ CH
00. Menu
CH separation RX FREQ CH
99. Exit
NEC-MIC-0807506 27 Ver.2.1
Training book Pasolink maintenance
RX level value
TX power value
IF cable connection status
BER alarm status
System alarm item
NEC-MIC-0807506 28 Ver.2.1
Training book Pasolink maintenance
Rx Level check
NEC-MIC-0807506 29 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 30 Ver.2.1
Training book Pasolink maintenance
Example 4
Alarm information from BTS NMS
BTS is down
Inspect on site
1.RX level=-75dBm
2.BER alarm
Trouble shooting procedure
1.Chek the configuration: Every thing is ok.
2.Chek the installation quality: Antenna is moved due to
the screw bolt loosed.
Solution:
To do antenna pointing again and lock the screw bolt.
RX level=-35dBm, BTS is on air.
NEC-MIC-0807506 31 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 32 Ver.2.1
Training book Pasolink maintenance
Monitoring
1. Monitoring voltage
3. Monitoring of alarm/status 2/2
2. Monitoring voltage
MOD ALM (alarm:-/-)
(continuous mode) Press 3 and ENTER
DEM ALM (alarm:-/-)
3. Alarm/Status OPR ALM ) (alarm:-/-)
4. Inventory MDP CPU ALM (alarm:-/*)
00. Menu ODU
Select item No. : 3 TX PWR ALM (alarm:-/-)
RX LEV ALM ) (alarm:-/-)
APC1 ALM (alarm:-/-)
Alarm condition is indicated by * APC2 ALM (alarm:-/-)
IF INPUT ALM (alarm:-/-)
and normal condition by -. MUTE (on)
TX/RX FREQ CH (1ch )
NEC-MIC-0807506 33 Ver.2.1
Training book Pasolink maintenance
Example 5
Solution:
To assembly IF connector with IF cable again,
RX level=-33dBm, BTS is on air.
NEC-MIC-0807506 34 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 35 Ver.2.1
Training book Pasolink maintenance
Example 6
Alarm information from BTS NMS
E1 BER alarm
Inspect on site by LCT
1.RX level=-36dBm
2.Low BER alarm (sometimes)
3.Restart MW system: BER alarm disappeared.
4.Low BER alarm (after 20 minutes)
Trouble shooting procedure
1.Dismounted the IF connector (In door).
2.Vision Check the installation quality : It is not good
connection between IF connector and IF cable.
Solution:
To assembly IF connector with IF cable again,
Low BER alarm disappeared, BTS is on air.
NEC-MIC-0807506 36 Ver.2.1
Training book Pasolink maintenance
IDU Fault isolation
ODU Fault isolation
Trouble shooting by LED indication
Example for IDU fault
NEC-MIC-0807506 37 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 38 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 39 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 40 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 41 Ver.2.1
Training book Pasolink maintenance
LED indication
1+0 1+1
LED Indication Fault Location
IDU IDU (Check by LCT)
ODU ODU (Check by LCT)
Note *: When the IF cable between the IDU and ODU is electric short
circuit condition or open condition, the IDU and ODU ALM LEDs
are synchronously flashing.
NEC-MIC-0807506 42 Ver.2.1
Training book Pasolink maintenance
Example 7
Alarm information from BTS NMS
BTS is down
Water
Inspect on site
1.LCT cant access IDU
2.Vision Check: IDU covered by rain water.
Rain water leakage due to bad water proof of feeder
hole. IDU damaged due to water leakage.
Solution:
To do water proof for feeder hole
and replace IDU
MW system is normal and BTS on air.
Feeder hole
NEC-MIC-0807506 43 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 44 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 45 Ver.2.1
Training book Pasolink maintenance
NEC-MIC-0807506 46 Ver.2.1