Sieve Analysis and Hydrometer Tests Lab Report
Sieve Analysis and Hydrometer Tests Lab Report
Sieve Analysis
OBJECTIVES
INTRODUCTION
In the sieve analysis process, soil is basically shaken through a set of sieves that have progressively
smaller openings. Sieves that are taken for the process are U.S. standard sieves. Sieve analysis of soil
is categorized under mechanical analysis of soil which determines the size range of particles present
in a soil expressed as a percentage of the total dry weight. Sieve analysis can only be implemented for
the soils with particle sizes larger than 0.075 mm in diameter (passing through No. 200 sieve). Where
a large portion of the soil particles is smaller than 0.075 mm, hydrometer analysis is used to define the
particle size distribution.
THEORY
Percentage retained on any sieve = (Weight of soil retained/Total soil weight) x 100
Cumulative percentage retained on any sieve = sum of the percentages retained on the sieve
Coefficient of uniformity (Cu); an indication of the spread of particle size which is calculated as,
Cu = D60/D10
Coefficient of concavity (Cc); a measure of the shape of the curve between D60 and D10 grain size and
is defined as;
where D10, D30 and D60 are the soil diameters, at which 10%, 30%, and 60% soil weights are finer,
respectively.
APPARATUS
Set of sieves (2.36mm, 1.18mm, 0.85mm, 0.6mm, 0.425mm, 0.25mm and 0.075mm) U.S
Standard
Sieve shaker
Sample splitter Larger evaporation dishes
Spatula
Brush
Balance sensitive to 0.1 g
Mortar and pestle
PROCEDURES
The air dried soil was used and aggregation of lumps were thoroughly broken up with the fingers.
Large soil samples to be divided by using the sample splitter to preserve their grain size distribution.
Testing procedure
Shukla, R. L. (2005). Principles of Soil Physics. New York: Taylor & Francis.
Particle Size Analysis of Soils AASHTO Designation T 88 (Mn/DOT Modified) viewed 2 October
2016, http://www.dot.state.mn.us/materials/manuals/laboratory/1302.pdf
Hydrometer Analysis
OBJECTIVES
To determine the particle-size distribution of a soil sample where the particle size is smaller than
0.075 mm in size.
INTRODUCTION
Hydrometer analysis is governed by the principal of sedimentation of soil grains in water. The
settlement of a diffused soil sample in water depends on the shape, size, and weight of the soil particles
and the viscosity of the water. Throughout the analysis soil particles are assumed to be spheres and the
velocity of soil particles is expressed by Stokes law.
THEORY
Stokes Law provides the relationship among the terminal velocity of fall of sphere in a fluid, the
diameter of a sphere, the weights of the sphere, and the viscosity of the fluid.
Hydrometer reading is a measure of soil mass in suspension at the level of the bulb. The grams of soil
still in suspension after elapsed time t can be obtained from the actual hydrometer reading (Ra). To
determine the correction (Cd) due to the dispersing agent on hydrometer readings, readings should be
obtained within a sedimentation cylinder with distilled water and same amount dispersing agent as that
used in soil-water suspension. Meniscus error (Cm) is usually occurred while readings are taken to the
top of the meniscus due to the invincibility of bottom of the meniscus as it is surrounded by colored
water. Hence, correction of meniscus (Cm) is applied to the hydrometer readings prior calculating the
percentage finer of soil.
Corrected hydrometer reading (Rc) = Ra (Cd Cm) where, Ra is the actual reading of the
hydrometer.
Percentage finer (P) = (Rc x a x 100)/W % where, W is the weight of soil in suspension and value
of a = 1.
Weight of soil finer than a particular particle size in given soil fraction (W1) passing through No 200
sieve = (W1 x P) g
Percentage finer than particular particle size of the soil sample used in sieve analysis;
= ((W1 x P)/W2) x 100 where, W2 is the total weight of the sample used for sieve analysis.
APPARATUS
Hydrometer
Mixer
Dispersing agent
Two graduated cylinders (1000 ml)
Thermometer
Balance sensitive to 0.1 g
Timer
Measuring cylinder
Distilled water
Drying oven
Desiccator
Syringe
Large evaporation dishes
Spatula
50g of soil was accurately weighted. Weighted soil was placed in a beaker and 125 ml of the Sodium
Hexametaphosphate solution (40g/litre) was added. Mixture was stirred using a mixture and kept to
soak for 16 hours. Base solution of 1000ml and the same amount of dispersing agent was prepared in
a separate measuring cylinder.
Soaked soil sample was transferred to the cup of mixer. Water was added to half fill the cup
and it was stirred for 3 minutes.
Soil water slurry was transferred to the glass sedimentation cylinder, and distilled water was
added until the total water is 1000 ml.
Cylinder was shaken vigorously by turning it upside down and back using the palm of the hand
over the open end of the cylinder, for a period of 1 min or more, until a uniform suspension is
formed.
Hydrometer was inserted carefully into the soil-water suspension.
Hydrometer readings were taken at following time intervals. min, 1min, 2min, 4min, 8min,
15min, 30min, 1hr, 1.5 hrs and 24 hrs.
REFERENCES
CIVILBLOG.ORG 2015, Hydrometer Analysis of soil what, why & how? viewed 2 October 2016,
http://civilblog.org/2015/11/18/hydrometer-analysis-of-soil-what-why-how/#
Dr. George Mylonakis 2005, Hydrometer Analysis', The Lab Manual, The City College of New
York.
Importance of Particle Size Distribution Emphasized in Proposed ASTM Soil and Rock Standards,
Shukla, R. L. (2005). Principles of Soil Physics. New York: Taylor & Francis.