Dialux Calculation (Scheme-1 Villa)
Dialux Calculation (Scheme-1 Villa)
Dialux Calculation (Scheme-1 Villa)
(SCHEME-1 VILLA)
VILLA - SCHEME 1
Date: 06 / 12 / 2014
Operator: FAEC+CBT
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
37 Pieces NARDEEN LIGHTING CO. SMP 240W SMP See our luminaire
2/40W RS HPF catalog for an image of
Article No.: SMP 240W the luminaire.
Luminous flux (Luminaire): 3761 lm
Luminous flux (Lamps): 5600 lm
Luminaire Wattage: 80.0 W
Luminaire classification according to CIE: 78
CIE flux code: 48 77 91 78 67
Fitting: 2 x T38 40W CW 2800 LUMEN
(Correction Factor 1.000).
Page 2
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
37.16 12.96 ft
37.16
32.52 32.52
41.81 41.81
41.81
37.16
37.16 41.81 46.45 46.45
41.81
46.45
41.81 46.45 41.81 37.16
37.16 46.45
46.45 46.45
41.81
0.00
0.00 13.78 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:51
Workplane:
Height: 2.493 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.705, Ceiling / Working Plane: 0.651.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 4 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 15045 Total: 22400 320.0
Specific connected load: 1.79 W/sq ft = 0.46 W/sq ft/10 fc (Ground area: 178.57 sq ft)
Page 3
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
12.96 ft
41.81
41.81
37.16 37.16
46.45 46.45
46.45
41.81
46.45 51.09 51.09
41.81
51.09
41.81 51.09
51.09
51.09 41.81
51.09
41.81 46.45
46.45 46.45
41.81
41.81
41.81
37.16 37.16
0.00
0.00 12.16 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:51
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 4 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 15045 Total: 22400 320.0
Specific connected load: 2.03 W/sq ft = 0.48 W/sq ft/10 fc (Ground area: 157.57 sq ft)
Page 4
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
15.72 ft
44.59
44.59 39.02
39.02 50.17 50.17
50.17
44.59 55.74 55.74 55.74
44.59
50.17
50.17 55.74
44.59
55.74 44.59
55.74
50.17 55.74 55.74 55.74
44.59
50.17 50.17 44.59
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:62
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 6 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 22567 Total: 33600 480.0
Specific connected load: 2.02 W/sq ft = 0.42 W/sq ft/10 fc (Ground area: 237.12 sq ft)
Page 5
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
9.78 ft
41.81
51.09
46.45 51.09 51.09
46.45
55.74
51.09
51.09
55.74
51.09 51.09
55.74
51.09 51.09
46.45 41.81
0.00
0.00 7.87 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:39
Workplane:
Height: 2.493 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.791, Ceiling / Working Plane: 0.847.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 3 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 11284 Total: 16800 240.0
Specific connected load: 3.12 W/sq ft = 0.62 W/sq ft/10 fc (Ground area: 76.98 sq ft)
Page 6
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
13.12 ft
26.01
29.73 29.73
26.01
33.44 33.44
29.73 33.44
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:52
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 4 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 15045 Total: 22400 320.0
Specific connected load: 1.30 W/sq ft = 0.41 W/sq ft/10 fc (Ground area: 245.37 sq ft)
Page 7
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
13.91 ft
29.73
26.01 26.01
33.44 33.44 33.44
37.16
37.16 33.44
33.44
37.16
37.16 37.16 33.44
29.73
33.44 33.44
29.73
0.00
0.00 16.40 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:55
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 4 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 15045 Total: 22400 320.0
Specific connected load: 1.40 W/sq ft = 0.42 W/sq ft/10 fc (Ground area: 228.19 sq ft)
Page 8
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
5.15 ft
32.52 37.16
37.16
37.16 32.52
41.81 41.81
37.16 41.81
41.81
37.16
46.45 41.81
37.16 41.81 46.45
46.45 41.81
37.16
41.81
37.16 41.81
41.81 41.81 37.16 32.52
37.16
37.16
32.52
27.87
0.00
0.00 8.27 ft
Height of Room: 7.874 ft, Mounting Height: 8.366 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:21
Workplane:
Height: 2.297 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.593, Ceiling / Working Plane: 0.250.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN DL-100G 2X26W TC-D HPF
1 2 1863 3600 56.3
(1.000)
Total: 3726 Total: 7200 112.6
Specific connected load: 2.64 W/sq ft = 0.73 W/sq ft/10 fc (Ground area: 42.59 sq ft)
Page 9
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
32.52 5.29 ft
27.87
32.52 37.16
37.16
37.16 32.52
41.81 41.81
37.16
41.81
41.81
46.45 41.81 37.16
37.16 41.81 46.45 46.45
41.81
37.16
41.81
37.16 41.81
41.81 41.81
37.16 32.52
37.16
32.52 37.16
32.52 27.87
0.00
0.00 8.27 ft
Height of Room: 7.874 ft, Mounting Height: 8.366 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:21
Workplane:
Height: 2.297 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.585, Ceiling / Working Plane: 0.247.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN DL-100G 2X26W TC-D HPF
1 2 1863 3600 56.3
(1.000)
Total: 3726 Total: 7200 112.6
Specific connected load: 2.58 W/sq ft = 0.72 W/sq ft/10 fc (Ground area: 43.72 sq ft)
Page 10
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
33.44 12.96 ft
27.87
33.44
39.02
27.87 39.02 39.02
33.44
27.87
39.02
44.59 39.02 33.44
44.59 44.59
33.44 44.59
39.02 39.02
44.59
44.59 33.44 27.87
39.02
33.44
39.02 39.02
27.87
27.87
33.44
0.00
0.00 16.81 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:51
Workplane:
Height: 2.297 ft
Grid: 32 x 32 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.650, Ceiling / Working Plane: 0.612.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 4 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 15045 Total: 22400 320.0
Specific connected load: 1.47 W/sq ft = 0.43 W/sq ft/10 fc (Ground area: 217.90 sq ft)
Page 11
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
12.96 ft
27.87
32.52 37.16 37.16
27.87
37.16 32.52
37.16 41.81 41.81
41.81
32.52
37.16
37.16 32.52
46.45
37.16
32.52 37.16
41.81
41.81 41.81 32.52
37.16
37.16
32.52 37.16
0.00
0.00 15.01 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:51
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 4 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 15045 Total: 22400 320.0
Specific connected load: 1.65 W/sq ft = 0.45 W/sq ft/10 fc (Ground area: 194.52 sq ft)
Page 12
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
18.96 ft
29.73
37.16
40.88
40.88
40.88
37.16
33.44
29.73
0.00
0.00 4.92 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:75
Workplane:
Height: 2.493 ft
Grid: 16 x 64 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.894, Ceiling / Working Plane: 0.989.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 3 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 11284 Total: 16800 240.0
Specific connected load: 2.59 W/sq ft = 0.72 W/sq ft/10 fc (Ground area: 92.68 sq ft)
Page 13
VILLA - SCHEME 1
06 / 12 / 2014
Operator FAEC+CBT
Telephone
Fax
e-Mail
6.00 ft
22.30
24.15 24.15
26.01
26.01
26.01
26.01
26.01 26.01 26.01
24.15
24.15
24.15
22.30
0.00
0.00 5.82 ft
Height of Room: 9.842 ft, Mounting Height: 9.842 ft, Light loss factor: 0.80 Values in Footcandles, Scale 1:24
Workplane:
Height: 2.493 ft
Grid: 16 x 16 Points
Boundary Zone: 0.000 ft
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.997, Ceiling / Working Plane: 1.265.
No. Pieces Designation (Correction Factor) (Luminaire) [lm] (Lamps) [lm] P [W]
NARDEEN LIGHTING CO. SMP 240W SMP
1 1 3761 5600 80.0
2/40W RS HPF (1.000)
Total: 3761 Total: 5600 80.0
Specific connected load: 2.29 W/sq ft = 0.94 W/sq ft/10 fc (Ground area: 34.96 sq ft)