What should you do first before any work is to be Close all manually
carried out on a burner in an automatically fired operated fuel valves
boiler?
What reading will be obtained if we use a dry Very inaccurate
uncoated sounding rod or tape to measure the depth
of water in a reserve feed water tank?
Diesel engine control can be obtained by the bridge only after the engine
__________. room control station is
switched to Bridge
Control
Where is the contaminated oil enters the centrifuge in At the top through the
a disk type centrifugal purifier? regulating tube
Why is condensate being pumped from the Condensate should
condenser to the DC heater instead of directly to the be deaerated before
boiler? entering the boiler
Most large main propulsion diesel engines use a ensure a positive flow
duplex lube oil strainer to _______. of oil at all times
While at sea, the flash type evaporator is discharging Continue the current
the output to the distill tanks. If it becomes evaporator operation
necessary to reduce the feed water temperature
below 165oF, you should _____.
When an auxiliary boiler is panting and emitting black increase the air
smoke, you should ______. supply
In diesel engines, hydraulic valve lifters are used to reduce valve gear
_________. pounding
Reduction gear lube oil temperatures for keel cooler higher than raw water
installations are generally _________. cooled installations