Table of contents
General informations
General information............................................................................................... 4
Selection table..................................................................................................... 8
Measuring scale with steel carrier LMB................................................................. 13
Miniature scanning heads with external electronics LMK...................................... 21
Scanning heads with integrated electronics LMK.................................................. 27
Measuring rail LMF................................................................................................ 37
Scanning head LMK.............................................................................................. 43
Output signals........................................................................................................ 47
Reference marks................................................................................................... 48
Limit switch function............................................................................................... 50
Cable..................................................................................................................... 53
Plug and connection assignments......................................................................... 54
ELECTROMATE
3
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
AMOSIN - Lngenmesssysteme Allgemeine Informationen
AMOSIN length measuring systems General informations
AMOs proven AMOSIN technology for length and angle measurements uses techniques for scanning high precision graduations consisting
of structures photo-lithographically etched onto steel. Based on this, inductive sensors and integrated evaluation electronics (ASIC) have been
developed to create a new and powerful generation of measuring systems.
The AMOSIN length measuring systems are supplied as open, nonguided systems or as guided encapsulated systesms. AMOSIN systems
are very well able to resist environmental influences such as dust, humidity and so forth, and also feature extremely high resistance to shock and
vibration.
The high precision is mainly due to the procedure used to manufacture the rigid steel measuring scale, and to the exceptionally high quality sensor
signal, with deviations in the sine wave down to < 0.1 % harmonic content, as a measure of the achievable interpolation precision within the gra-
ting pitch. As will be seen from the measuring principle described below, the measuring system does not include any magnetic parts (either in the
scale or in the scanning head). As a result it is not at all sensitive to electromagnetic interference of any kind and has no hysteresis in contrast to
magnetic measuring systems. The systems output interfaces either 1 Vpp sine/cosine signals, or RS-422 square wave signals, in real-time.
The wide range of available AMOSIN length measuring system types covers a wide area of applications from high accuracy positioning for mea-
suring machines and pick and place machines over machine tool, sheet metal working machines to direct drives where high dynamic range and
stiffness is required.
General properties
Not sensitive to soiling - IP67 Operation temperature -10C to 100C
Not sensitive to interfering magnetic fields Analog output 1Vpp with divided signal period till 10m
High precision Digital output RS-422 / TTL with resolution till 0,125m
Typical applications
Machine tool Medical equipment
ELECTROMATE
4 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Allgemeine Informationen AMOSIN - Lngenmesssysteme
General informations AMOSIN length measuring systems
An important feature of the principle of operation is that using the AMOSIN technology does not give rise to any measurement hysteresis (ma-
chine backlash error). In contrast to magnetic systems, the high-frequency alternating field suppresses any hysteresis in the material.
The evaluation electronics conditions the sensor signals and interpolates them continuously, without strobe times, exploiting a novel circuit prin-
ciple. It then supplies the measurement information at the output through differential interfaces and linedrivers, either as a sinusoidal signal or as
a square wave signal. (See the signal diagram on Page 47)
In addition to the periodic quadrature signals (A, B and their inverted) a reference signal is output for the determination of absolute position. This
signal is generated from individual marks integrated into the measuring scale, and does not require any additional parts. (See the description of
the reference signal on Page 48)
AMOSIN MESSSYSTEM
EEPROM
Konfigurationsdaten
AMOSIN MEASURING SYSTEM
Configuration data (Fig. 2)
Versorgungseinheit
Power supply unit
Analog Ausgang
~ 1 Vss
ASIC Signal- Analog output
konditionierung ~ 1 Vpp
+ Auswertung
ASIC signal
conditioning Encoder Ausgang
+ evaluation Encoder output
RS 422
Kompensationssignale
Compensation signals
Sensoreinheit Auswerteelektronik
Sensor unit Electronic evaluation stage
Mass- Abtastkopf
Verkrperung Measuring head
Measuring
scale
ELECTROMATE
5
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
AMOSIN - Lngenmesssysteme Allgemeine Informationen
AMOSIN length measuring systems General informations
Measuring accuracy
The total error of a measuring system is caused by the following measuring inaccuracies:
The following should also be considered for the measuring systems with a 1 Vpp output interface:
3. Precision of the analog/digital conversion at the input stage of the subsequent electronics (in the controller)
4. Noise coupled into the output signals as it is transferred from the scanning head to the subsequent electronics
1. Scale accuracy
Every measuring scale is measured on a linear test bench and a test certificate quoting the precision class in accordance with the specification,
is completed. Optionally a measuring diagram (registered under ideal assembly conditions) can be supplied as follows.
20
15
10
Abweichung [m]
5
Error [m]
-5
-10
-15
-20
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400
Messlnge [mm]
Measuring length [mm]
The periodical deviation which appears within the grating pitch is less than 0,1% of the pitch because of the high quality of the sensor signal and
the signal evaluation (e.g.. maximum deviation is 0,5m on a 500m grating pitch).
This high accuracy level will be achieved not just for the ideal, nominal mounting and environmental conditions but for the whole specified func-
tional range of geometrical mounting deviations and temperature.
In order to suppress the errors discussed above under points 3 and 4, a new output interface has been implemented in the new generation of
AMOSIN systems, in which the sine, cosine and reference signals, for the 1 Vpp output interface can be divided and delivered over line drivers
(see signal diagram on Page 47). The divided output signals (with programmable dividing factor) are generated in real time with signal periods
down to 10 m.
The effect of any possible deviation in the evaluation of the encoder signals in the subsequent electronics (controller etc.), is reduced exactly by
the dividing factor that is applied. In addition, this reduced sinusoidal signal period leads to finer quantisation in the subsequent electronics, which
is of particularly great importance to demanding high stability, high stiffness drive applications. Additionally, the signal dividing reduces the effect of
interfered noise on the signal transfer line in proportion to the dividing factor; in other words, an improved signal/noise ratio is achieved.
The metrological principle on which the AMOSIN systems operate means that they are entirely free from hysteresis and dont lead to a backlash
effect.
ELECTROMATE
6 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Allgemeine Informationen AMOSIN - Lngenmesssysteme
General informations AMOSIN length measuring systems
ELECTROMATE
7
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
AMOSIN - Lngenmesssysteme Allgemeine Informationen
AMOSIN length measuring systems General informations
Selection Table
High resolution High mounting tolerances
High accuracy High dynamic
Grating pitch
500 m 1000 m 3000 m
Scale with adhesive Scale mounted on
carrier
Mabandtyp
LMB-100 LMB-400
LMK-105x LMK-10x
-
Page 21 Page 21
Abtastkopftyp
LMK-100
Standard flat
LMK-115x LMK-11x LMK-13x
LMKF-115x LMKF-11x LMKF-13x
LMK-110 LMKF-110
Measuring rail
Scale type
LMF-3150 LMF-310
LMF-3250 LMF-320
-
Page 37 Page 37
Guided systems
Measuring slider
Scanning head type
LMK-315x LMK-31x
-
Page 43 Page 43
ELECTROMATE
8 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Measuring scales for non guided AMOSIN measuring systems
ELECTROMATE
9
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Maverkrperung
Open AMOSIN length measuring systems Scale types
At the open, non-guided systems a double sided adhesive foil is applied on the measuring scale for direct sticking on the machine bed. At all of
these versions the scanning still takes place without contact and is therefore not subject to wear.
Depending on the application a grating pitch of 500 m, 1000 m or 3000 m can be used.
To determine the absolute position along the axis the scale has integrated reference marks. These reference marks can be realized as a single,
multiple or distance coded pattern.
Configuration
Abdeckband
Cover tape
Doppelseitiges Klebeband
Adhesive tape
Maband
Measuring tape
Trgerband
Carrier tape
Technical data
Grating pitch:
500 m 1000 m 3000 m
Coefficient of expansion:
~ 11 ppm/K
Measuring length:
Any lengths up to 30m
Mechanical execution:
Stainless steel measuring tape with adhesive layer for mounting
Reference marks:
1 reference mark as standard or any desired number and position or distance coded
(see page 48)
ELECTROMATE
10 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Maverkrperung Offene AMOSIN - Lngenmesssysteme
Scale types Open AMOSIN length measuring systems
+ Zhlrichtung
Count direction
RI-Position 1mm
ML = GL - 35,5 mm
Zhlrichtung
+ Count direction
RI-Position 1mm
ML = GL - 49 mm
Zhlrichtung
+ Count direction
RI-Position 1mm
Ordering code
LMB- . - -
Overall length in mm
RI - Position
00 ........ none
02 ........ centered
Scale / scanning head combination Lxxx .... xxx mm from left
Linearity Error Rxxx .... xxx mm from right
100 ... LMK-100 Bxxx .... xxx mm from both sides
110 ... LMK-110 / LMKF-110 1 ... 10 m/m Kxx ..... distance-coded (basic spacing xx grating pitches)
1050 ... LMK-1050 2 ... 5 m/m A050 .. RI every 50mm (for 1mm pitch only)
1150 ... LMK-1150 / LMKF-1150 3 ... 3 m/m
ELECTROMATE
11
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Maverkrperung
Open AMOSIN length measuring systems Scale types
Zhlrichtung
+ Count direction
RI-Position 1,5mm
Zhlrichtung
+ Count direction
RI-Position 1,5mm
ML = GL - 49 mm
Ordering code
LMB- . - -
Overall length in mm
RI - Position
00 ........ none
Linearity Error 02 ........ centered
Lxxx .... xxx mm from left
Scale / scanning head combination 0 ... 20 m/m Rxxx .... xxx mm from right
1 ... 10 m/m Bxxx .... xxx mm from both sides
130 ... LMK-130/ LMKF-130 2 ... 5 m/m Kxx ..... distance-coded (basic spacing xx grating pitches)
ELECTROMATE
12 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Maverkrperung Offene AMOSIN - Lngenmesssysteme
Scale types Open AMOSIN length measuring systems
The scale type LMB-400 is designed for harsh applications where adhesive backed scale tape is not appropriate. A slim stainless steel carrier is
attached to the machine with screws, with an interlocking snap cover securing the scale tape in position.
Depending on the application a grating pitch of 500 m, 1000m or 3000 m can be used. Any non-guided AMOSIN encoder head can be used
with any of the LMB-400 scale mounting version.
To determine the absolute position along the axis the scale has integrated reference marks. These reference marks can be realized as a single,
multiple or distance coded pattern.
Configuration
"Schnapp" Abdeckung
"Snap" cover
Maband
Scale
Mabandklemme
Scale fixing bracket
Mabandtrger Trgerband
Scale carrier Carrier tape
ELECTROMATE
13
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Maverkrperung
Open AMOSIN length measuring systems Scale types
Mounting on the machine without any adhesive (ideal for harsh environments, replacement or repairable mounting is possible)
Standard one meter carrier length, can be butted together for ease of installation, optional single carriers up to three meters are
available
Technical data
Grating pitch:
500 m 1000 m 3000 m
Coefficient of expansion:
~ 11 ppm/K
Measuring length:
Single carrier up to 3 m, unlimited lengths with multiple carriers
Mechanical execution:
Stainless steel measuring tape mounted on stainless steel carrier
Reference marks:
1 reference mark as standard or any desired number and position or distance coded
(see page 48)
ELECTROMATE
14 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Maverkrperung Offene AMOSIN - Lngenmesssysteme
Scale types Open AMOSIN length measuring systems
Single carrier up to 3000 mm in length for 500m and 1000m grating pitch
Overall length in steps of 100 mm
GL = (m + 1) x 100 [mm]
i.e.: 200 mm, 300 mm, ... , 3000 mm
Scale loose mounted on the carrier and fixed with the cover tape
Can be combined with standard AMOSIN - scanning heads
18
A-A (2 : 1) 10
7,5
6,9
5,1
A
0,5x45
0 0
50 - 0,5 100 50 -0,5
m x 100 4,5
Flachkopfschraube
Flat head screw 14 0,05
4x6 DIN 7984
Aufkleber Referenzmarke
Reference mark sticker
Zhlrichtung
Maband Mabandtrger "Schnapp"- Abdeckung Abtastkopf + Count direction
Scale Scale carrier "Snap"- cover Scanning head
Referenz
Reference
ELECTROMATE
15
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Maverkrperung
Open AMOSIN length measuring systems Scale types
Multiple carriers in 1000 mm modules for 500m and 1000m grating pitch
Overall length in steps of 200 mm
GL = (n x 1000) + RL [mm]
i.e.: 1200 mm, 1400 mm, 1600mm, ...
Scale loose mounted on the carrier and fixed with the cover tape
Any measuring lengths
Can be combined with standard AMOSIN - scanning heads
18
A-A (2 : 1) 10
7,5
Trgerprofil Stostelle
Carrier joint point
3
A
6,9
0 0 0 0
0,5x45
50 - 0,5 100 50 -0,5 50 -0,5 A 50 -0,5
5,1
9 x 100 100 9 x 100 100 4,5
Flachkopfschraube
Flat head screw 14 0,05
M4x6 DIN 7984
Aufkleber Referenzmarke
Reference mark sticker + Zhlrichtung
Count direction
Maband Mabandtrger "Schnapp" Abdeckung Abtastkopf Mabandklemme
Scale Scale carrier "Snap" cover Scanning head Scale fixing bracket
Referenz
Reference
I
Referenz Marke
Reference mark
10 ML KL 10
GL
1000 1000 RL
ELECTROMATE
16 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Maverkrperung Offene AMOSIN - Lngenmesssysteme
Scale types Open AMOSIN length measuring systems
LMB - 430
Single section carrier, type E2
A-A (2 : 1)
22
14
7,5
A
6,9
05x45
5,1
0 0
50 - 0,5 100 50 - 0,5
A 4,5
mx100
Flachkopfschraube
Flat head screw 18 0,05
Aufkleber Referenzmarke 4x8 DIN 7984
Reference mark sticker
Abtastkopf + Zhlrichtung
Count direction
Maband Scanning head
Scale Mabandtrger "Schnapp"- Abdeckung
Referenz Scale carrier "Snap"- cover
Reference
ELECTROMATE
17
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Maverkrperung
Open AMOSIN length measuring systems Scale types
LMB - 430
Multiple section carrier, type M2
22
A-A (2 : 1) 14
Trgerprofil Stostelle 7,5
Carrier joint point A
6,9
5,1
3
0 0 0 0
50 - 0,5 100 50 - 0,5 50 - 0,5 50 - 0,5
A
9x100 100 9x100 100
4,5
Flachkopfschraube
Flat head screw 18 0,05
M4x6 DIN 7984
Aufkleber Referenzmarke
Reference mark sticker
Mabandtrger "Schnapp" Abdeckung + Zhlrichtung
Count direction
Maband Scale carrier "Snap" cover
Scale Referenz
Reference Mabandklemme
Scale fixing bracket
Referenz Marke
Reference mark
10 ML KL 10
GL
nx1000 RL
1000
ELECTROMATE
18 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Maverkrperung Offene AMOSIN - Lngenmesssysteme
Scale types Open AMOSIN length measuring systems
Zhlrichtung
+ Count direction
RI-Position 1mm
Zhlrichtung
+ Count direction
RI-Position 1mm
Zhlrichtung
+ Count direction
RI-Position 1mm
Zhlrichtung
+ Count direction
RI-Position 1,5mm
+ Zhlrichtung
Count direction
RI-Position 1,5mm
ELECTROMATE
19
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Maverkrperung
Open AMOSIN length measuring systems Scale types
LMB- . - - -
Overall length in mm
LMB- . - - -
Overall length in mm
ELECTROMATE
20 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Miniature scanning head for non guided AMOSIN
measuring systems
ELECTROMATE
21
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Miniaturabtastkopf
Open AMOSIN length measuring systems Miniature scanning head
The open, non-guided miniature scanning heads are best suited for applications with small construction space. The evaluation electronics is im-
plemented in the external connector. The scanning heads can be combined with measuring scale types LMB-100 or LMB-400 (see page 9).
The grating pitch must be the same for the scanning head and the scale. As an option an integrated limit switch function can be realized.
The systems are insensitive against environmental pollution (like oil, coolant, dust ...).
Technical data
ELECTROMATE
22 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Miniaturabtastkopf Offene AMOSIN - Lngenmesssysteme
Miniature scanning head Open AMOSIN length measuring systems
Possible resolutions
Output signal
Sine 1 Vpp TTL
Signal periods Periods
Dividing Period Max. speed Power Max. speed Power
Type consumption(2) Type consumption(2)
factor length Interpolation Resolution (1)
factor
LMK LMK
[m] [m/s] [mA] at 5V [m] [m/s] [mA] at 5V
ELECTROMATE
23
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Miniaturabtastkopf
Open AMOSIN length measuring systems Miniature scanning head
35,5
0,6 (LMB-1050)
0,8 (LMB-100)
= 16 = ~6
5,2
12
0,1
12
Luftspalt mit Folie eingestellt
Air gap set with spacer film
0,1 0,05 (LMK-1050)
2x 3,5 0,1
0,1/1000
=
10
0,1
Referenzmarke mittig im Abtastkopf
Referenzmarke Maband Reference mark in the middle of the
Reference mark measuring scale scanning head
35,5
5
3,
= 16 =
2x
12
5,2
~6
0,1
0,03
(5,1)
12
Luftspalt mit Folie eingestellt
Air gap set with spacer film
0,10,05 (LMK-1050)
0,150,1 (LMK-100)
LMB-400 / LMB-4050
Zhlrichtung
+ Count direction
0,1/1000
Referenz
Reference
0,1
Referenzmarke mittig im Abtastkopf
Referenzmarke Maband Reference mark in the middle of the
Reference mark measuring scale scanning head
ELECTROMATE
24 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Miniaturabtastkopf Offene AMOSIN - Lngenmesssysteme
Miniature scanning head Open AMOSIN length measuring systems
27
27
14,5
14,5
~10 67 22 67
~111
9 9
5,2
17
25
25
17
6
4,5 8/4tief
5
n
4,
ge 4,5 8/4deep 4,
5
run es
n
h
bo ol CONNEI-Kupplung
ge
ge g h es
un
nta tin
CONNEI-Kupplung ol Stift 12 pol.
hr
Mo oun Stift 12 pol. h CONNEI-coupling
bo
e g
ch
M CONNEI-coupling tin 8/4tief male 12 pin
ge
fl rface un 8/4deep
ta
male 12 pin
e o
ce on
s s u M
Ma nd s rfa eM
su h
ou
d c
Gr
un efl
ro ss
G Ma
14,5
16
2,5
67
~105
13,25
9 5,2
32,5
40
25
17
3
CONNEI-Kupplung 3, Sub-D connector 15 pin
n 5
en
12mm n Connei-coupling l
ru es
ru
eb g h in
g
b
12mm
tag ntin nt
ge
n
ou
ta
o o u
ce on
M M M
e
rfa e M
ch e
fl rfac
su h
d flc
e
s su
as
un e
M und
ro ss
o
G Ma
G r
ELECTROMATE
25
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Miniaturabtastkopf
Open AMOSIN length measuring systems Miniature scanning head
Ordering codes
LMK-1051. - - , - LMK-1052. - - , -
Connector type 1) Connector type 1)
Interpolation factor
2)
preferred cable length in steps of 0,5m 2)
preferred cable length in steps of 0,5m
LMK-101. - - , - LMK-102. - - , -
Connector type 1)
Connector type 1)
Interpolation factor
2)
preferred cable length in steps of 0,5m 2)
bevorzugte Kabellnge in 0,5m Schritten
1)
Connector electronics 3)
Limit switch (see on page 48 and following)
ELECTROMATE
26 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Scanning head with integrated electronics for non-guided
AMOSIN measuring systems
ELECTROMATE
27
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Abtastkopf mit integrierter Elektronik
Open AMOSIN length measuring systems Scanning head with integrated electronics
The open, non-guided miniature scanning heads with integrated electronics can be combined with measuring scale types LMB-100 or LMB-400
(see page 9).
The grating pitch must be the same for the scanning head and the scale. As an option an integrated limit switch function can be realized.
The systems are insensitive against environmental pollution like (like oil, coolant, dust ...).
Technical data
Signal period sine 1Vpp: 500m 20m 1000m 40m 3000m 120m
Resolution TTL: 25m 0,125m (1)
50m 0,25m (1)
150m 0,75m (1)
Detailed list of possible resolutions see on the next page
Max. speed: up to 30 m/s, details see table on the next page
Optional: LMK-115x and LMK-11x in combination with LMB-400 also available with wipers
ELECTROMATE
28 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Abtastkopf mit integrierter Elektronik Offene AMOSIN - Lngenmesssysteme
Scanning head with integrated electronics Open AMOSIN length measuring systems
Possible resolutions
Output signal
Sine 1 Vpp TTL
Signal periods Periods
Max. speed Power Max. speed Power
Type consumption(2) Type consumption(2)
Dividing Period Interpolation Resolution (1)
(1)
after 4-edge evaluation
(2)
with 120 termination resistors (see also description of output signals on page 47)
ELECTROMATE
29
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Abtastkopf mit integrierter Elektronik
Open AMOSIN length measuring systems Scanning head with integrated electronics
73
61
16
49
3
7,45 (LMK-110)
7,2 (LMK-1150)
5,2
0,1
22,5
,2 5
R2
3,5
29
0,03
10
0,150,1 (LMK-110)
0,8 (LMB-110)
Masseflche
LMB-110 / LMB-1150 Ground surface
Zhlrichtung
+ Count direction
3 0,5
0,1 0,1/1000
10
73
61
16
49
3
5,2
22,5
25
29
R2,
0,1
3,5
0,03
10
1 0,5 (LMK-110)
Luftspalt mit Folie eingestellt
Air gap set with spacer film
1 0,3 (LMK-1150) = =
11,8
0,10,05 (LMK-1150)
Masseflche
0,150,1 (LMK-110)
LMB-410 / LMB-4150
Zhlrichtung
+ Count direction
Referenz 0,1
Reference
ELECTROMATE
30 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Abtastkopf mit integrierter Elektronik Offene AMOSIN - Lngenmesssysteme
Scanning head with integrated electronics Open AMOSIN length measuring systems
Montagezeichnungen LMKF-110/1150
Assembly drawings LMKF-110/1150
49
30
5,2
0,03 0,1
13,5
Luftspalt mit Folie eingestellt
14,42 (LMKF-110)
14,2(LMKF-1150)
Air gap set with spacer film
3 0,5
0.1 0,05 (LMKF-1150)
0,15 0,1 (LMKF-110)
Zhlrichtung
+ Count direction
LMB-110 / LMB-1150
= 36 =
2,5
4
2x 0,1/1000
10
Referenzmarke Maband Referenzmarke mittig im Abtastkopf
Reference mark measuring scale 0,1 Reference mark in the middle of the
scanning head
4,55(LMKF-1150)
4,8 (LMKF-110)
0,6 (LMB-1150)
= 26 = 0,8 (LMB-110)
M3
2x
49 30
5,2
0,05
0,03
13,5
18,8
Luftspalt mit Folie eingestellt
14
Air gap set with spacer film
0,1
1 0,5 (LMKF-110)
0,10,05 (LMKF-1150)
0,150,1 (LMKF-110)
1 0,3 (LMKF-1150)
+ Zhlrichtung
Count direction
LMB-410 / LMB-4150
= 36 =
2,5
0,1/1000
Referenz
2x
Reference
4
= 26 =
9,1
2xM3
ELECTROMATE
31
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Abtastkopf mit integrierter Elektronik
Open AMOSIN length measuring systems Scanning head with integrated electronics
73
61 16
5,2
49 3
0,2
22,5
,25
R2
29
3,5
0,05
10
7,7
0,4 0,2
LMB-130
+ Zhlrichtung
Count direction
0,2 0,2/1000
1 1
14
73
16
61
3
49
5,2
,25
22,5
0,1
29
R2
3,5
0,05
10
12
= = 1 1
Luftspalt mit Folie eingestellt
18 Masseflche
Air gap set with spacer film
+
0,4 0,2
Zhlrichtung
Count direction
Referenz 0,1
Reference
ELECTROMATE
32 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Abtastkopf mit integrierter Elektronik Offene AMOSIN - Lngenmesssysteme
Scanning head with integrated electronics Open AMOSIN length measuring systems
49 30
5,2
0,05 0,2
13,5
14,7
Luftspalt mit Folie eingestellt
Air gap set with spacer film 2 1
Zhlrichtung
+ Count direction
0,4 0,2
= 36 = LMB-130
2,5
4
0,2/1000 2x
14
Referenzmarke mittig im Abtastkopf
Referenzmarke Maband 0,2 Reference mark in the middle of the
Reference mark measuring scale scanning head
= 26 =
0,8
5,05
M3
2x
30
49
5,2
0,05
0,1
13,5
19
Luftspalt mit Folie eingestellt
Air gap set with spacer film
12 1 18
0,4 0,2
0,1
Zhlrichtung
+ Count direction
= 36 = 4
2,5
2x
0,2/1000
Referenz
Reference
= 26 =
9,4
x4
M3
2x
ELECTROMATE
33
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Abtastkopf mit integrierter Elektronik
Open AMOSIN length measuring systems Scanning head with integrated electronics
Ordering code
LMK-1151. - - , - LMK-1152. - - , -
LMKF-1151. - - , - LMKF-1152. - - , -
Connector type 1)
Connector type 1)
Interpolation factor
2)
preferred cable length in steps of 0,5m 2)
preferred cable length in steps of 0,5m
LMK-111. - - , - LMK-112. - - , -
LMKF-111. - - , - LMKF-112. - - , -
Steckertyp 1) Connector type 1)
Connector type
Interpolation factor
ELECTROMATE
34 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Abtastkopf mit integrierter Elektronik Offene AMOSIN - Lngenmesssysteme
Scanning head with integrated electronics Open AMOSIN length measuring systems
Ordering code
LMK-131. - - , - LMK-132. - - , -
LMKF-131. - - , - LMKF-132. - - , -
Connector type 1)
Connector type 1)
Interpolation factor
2)
preferred cable length in steps of 0,5m 2)
preferred cable length in steps of 0,5m
1)
Connector type 3)
Limit switch (see on page 48 and
following)
0 .......none
1 .......2-pin DIN connector 0 ... without
3 .......9-pin Sub-D connector 1 ... with
4 .......12-pin CONNEI connector (male) L ... reference pulse selectable
5 .......15-pin Sub-D connector
6 .......12-pin CONNEI coupling (male)
9........Special connector or special pin-out
(requires special no. Sxx)
ELECTROMATE
35
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Offene AMOSIN - Lngenmesssysteme Abtastkopf mit integrierter Elektronik
Open AMOSIN length measuring systems Scanning head with integrated electronics
ELECTROMATE
36 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Measuring rail for guided AMOSIN measuring systems
ELECTROMATE
37
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Gefhrte AMOSIN - Lngenmesssysteme Maverkrperung
Guided AMOSIN length measuring systems Scale types
At the guided measuring systems the scale is integrated in a guiderail. The measuring rail for length till 3940mm is available in single or over
3940mm for multiple sections.
A mechanical length compensation to achieve highest absolute accuracies and multiple mounting/dismounting of the measuring rail is possible.
The optional length compensation is realized by stretching the measuring tape referred to a given absolute value by using the compensation
mechanism which is integrated in the measuring rail.
Depending on the application a grating pitch of 500 m oder 1000 m can be used.
To determine the absolute position along the axis the scale has integrated reference marks. These reference marks can be realized as a single,
multiple or distance coded pattern.
Configuration
Mabandklemme
(an beiden Enden)
Scale fixing bracket
(on both ends)
"Schnapp" Abdeckung
"Snap" Cover
Messschiene Maband mit
Measuring rail Trgerband
Measuring scale
with carrier tape
Montage Bohrungen
fr die Messschiene
Mounting hole for
the measuring rail Justierschraube fr
Lngenkompensation
Adjusting screw for
length compensation
Technical data
LMF-3150 LMF-310
Grating pitch:
500 m 1000 m
Coefficient of expansion:
~ 11 ppm/K
Measuring length:
Any lengths
Mechanical execution:
Standard guide rail with integrated measuring scale
Reference marks:
1 reference mark as standard or any desired number and position or distance coded
ELECTROMATE
38 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Maverkrperung Gefhrte AMOSIN - Lngenmesssysteme
Scale types Guided AMOSIN length measuring systems
7,4
16,2
10,3 0,5
4,4 15
Achtung!
Am Schienenende mit dem
0,4 Spannelement mu
ausreichend Platz fr die
Montage bzw. Demontage
des Messwagens frei bleiben.
Warning!
Equipment design
60 60 considers here free
0 0 space for slider
30 - 1,5 mx60 30 - 1,5 mounting.
7,4
16,2
10,3
10,3 0,5
4,4
15
0,4
Achtung!
Am Schienenende mit dem
Spannelement mu
ausreichend Platz fr die
Montage bzw. Demontage
des Messwagens frei bleiben.
0 0
30 - 1,5 mx60 30 30 64x60=3840 30 - 1,5 Warning!
Equipment design
considers here free
RL-Schienenreststck / Rest length rail nx3900 space for slider
mounting.
GL-Gesamtlnge / Overall length
ELECTROMATE
39
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Gefhrte AMOSIN - Lngenmesssysteme Maverkrperung
Guided AMOSIN length measuring systems Scale types
Schienenendstck "K"
Rail end "K"
7,4
16,2
10,3 0,5
15
4,4
50 50
Achtung!
0,4 Am Schienenende mit dem
Spannelement mu
ausreichend Platz fr die
Montage bzw. Demontage
des Messwagens frei bleiben.
Warning!
Equipment design
30 30 considers here free
30 30 space for slider
+1,5 +1,5 mounting.
20 0 60 60 20 0
mx60
Consisting of:
one or more guiding elements with 3900 mm length
7,4
16,2
10,3 0,5
4,4 15
64x60=3840
50 50
Achtung!
Am Schienenende mit dem
Spannelement mu
ausreichend Platz fr die
Montage bzw. Demontage
des Messwagens frei bleiben.
+1,5 +1,5
20 0 30 30 mx60 30 30 30 30 20 0 Warning!
Equipment design
considers here free
Schienenendstck "R" RL-Schienenreststck nx3900 Schienenendstck "L" space for slider
End rail "R" Rest length rail End rail "L" mounting.
ELECTROMATE
40 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Maverkrperung Gefhrte AMOSIN - Lngenmesssysteme
Scale types Guided AMOSIN length measuring systems
RI-position LMK-310/3150
+ Zhlrichtung
Count direction
RI-Position 1mm
LMF- . - -
Measuring length in mm
Coating RI - Position
LMF- . - -
Measuring length in mm
Coating RI - Position
ELECTROMATE
41
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Gefhrte AMOSIN - Lngenmesssysteme Maverkrperung
Guided AMOSIN length measuring systems Scale types
ELECTROMATE
42 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Scanning head for guided AMOSIN measuring systems
ELECTROMATE
43
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Gefhrte AMOSIN - Lngenmesssysteme Abtastkopf
Guided AMOSIN length measuring systems Scanning head
The guided scanning heads LMK-310 with integrated evaluation electronics can be combined with all measuring rails LMF-310 (see page 37).
The grating pitch must be the same for the scanning head and the scale. As an option an integrated limit switch function can be realized.
The systems are insensitive against environmental pollution (i.e. oil, coolant, ...). Because of the option to mount the scanning head using the
mounting spring high mounting tolerances, especially for longer measuring length, can be realized.
Technical data
ELECTROMATE
44 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Abtastkopf Gefhrte AMOSIN - Lngenmesssysteme
Scanning head Guided AMOSIN length measuring systems
Possible resolutions
Output signal
Sine 1 Vpp TTL
Signal periods Periods
Type Dividing Period Max. speed Power Type Max. speed Power
factor length consumption (2) Interpolation Resolution(1) consumption (2)
LMK LMK factor
(1)
after 4-edge evaluation
(2)
with 120 termination resistors (see also description of output signals on page 47)
10 11 Federelement
2x Mounting spring 19
4,5
M
M3 3/5
/5 tief 5,2
de
ep
51
46
39
31,5
23,5
2 2
52
58
RI Marke
RI mark
Referenzmarke mittig im Abtastkopf
3,3
Mabandklemme
Scale fixing bracket
34
14
(24)
22
RI Markierungplttchen
RI Marking plate
52x10x0,5
ELECTROMATE
45
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Gefhrte AMOSIN - Lngenmesssysteme Abtastkopf
Guided AMOSIN length measuring systems Scanning head
Ordering codes
LMK-3151. - - , - LMK-3152. - - , -
Connector type 1)
Connector type 1)
Interpolation factor
2)
preferred cable length in steps of 0,5m 2)
preferred cable length in steps of 0,5m
LMK-311. - - , - LMK-312. - - , -
Connector type 1)
Connector type 1)
Interpolation factor
2)
preferred cable length in steps of 0,5m 2)
preferred cable length in steps of 0,5m
1)
Connector type 3)
Limit switch (see on Page 48 and following)
ELECTROMATE
46 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Allgemeine technische Daten AMOSIN - Lngenmesssysteme
General technical data AMOSIN length measuring systems
ELECTROMATE
47
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
AMOSIN - Lngenmesssysteme Allgemeine technische Daten
AMOSIN length measuring systems General technical data
In order to determine the absolute position, a reference track is integrated onto the scale, parallel to the measuring track. This reference track
consists of one or more reference marks (marked on the measuring scale accordingly), which are detected by the scanning head.
The reference marks can be arranged in the following ways:
Single reference marks can be placed at any desired position on the measuring scale. As a standard, a single reference
mark is located in the middle of the measuring length. Any other position or multiple reference marks are possible. Identifier:
The position of the reference mark on the measuring scale is indicated with a black triangle.
Reference mark
The reference signal is validated at the output by passing the magnet mounted along the measuring scale. The magnet (supplied with the scale)
can be mounted at any position along the measuring scale to select the reference positon at customer site.
The traveling direction for homing should be always the same to get a repeatable reference position.
In this configuration the limit switch option is not available.
At the output for the refernce signal one reference pulse is generated each grating pitch. These reference pulses are generated from the scanning
head, i.e. no reference marks on the measuring scale are required.
This reference pulses can be used in combination with an external switch to select the reference position at any position along the measuring
stroke.
ELECTROMATE
48 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Allgemeine technische Daten AMOSIN - Lngenmesssysteme
General technical data AMOSIN length measuring systems
4. Abstandscodierte Referenzmarken
The distance coded distribution of the reference marks on the measuring scale allows the controller, if it has
implemented this functionality, to determine the absolute position after passing two neighbouring marks.
The position of the first reference mark, the basic spacing and the positive direction of counting is indicated on Basic spacing
the measuring scale. Positive direction
of counting
Arrangement for non divided output signals 1Vpp Arrangement for divided output signals 1Vpp
K K
K = K x D
K' K'
K ... Number of sine periods at the output of the measuring system K ... Number of divided sine periods at the output of the measuring system
equal to the number of grating pitches D ... Dividing factor
In general the maximum codable length can be calculated with the following formular:
ELECTROMATE
49
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
AMOSIN - Lngenmesssysteme Allgemeine technische Daten
AMOSIN length measuring systems General technical data
output
encoder
The limit switch sensor is located at the center of the scanning head. By passing the respec-
tive magnet a signal will be generated at the limit switch output LL or LR.
The limit switch output is implemented as an open-collector circuit (see circuit diagram).
evaluation
electronics
1. LMK-100/1050
Scale type LMB-100/1050
1 0,5
2
7
7
10
4
LMB-100/LMB-1050
2. LMK-100/1050
Scale type LMB-400/4050
2x
12
7
14
4
LMB-410/LMB-4150
3. LMK-110/1150
Scale type LMB-110/1150
Endlageschaltpunkt=Abtastkopfmitte
End position switching point
3 0,5
1
11
4
15
16
Sold & Serviced By:
ELECTROMATE
50 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Allgemeine technische Daten AMOSIN - Lngenmesssysteme
General technical data AMOSIN length measuring systems
4. LMK-110/1150
Scale type LMB-410/4150
Endlageschaltpunkt=Abtastkopfmitte
End position switching point
=centre of scanning head
LMB-410/LMB-4150
1 0,5
14
1
16
11,25
10
3,3 Endlage links "L" Endlage rechts "R"
2x
8 End position left "L" End position right"R" 4 15,32
16
19,32
5. LMKF-110/1150
Scale type LMB-110/1150
0,25
Endlageschaltpunkt=Abtastkopfmitte
End position switching point
=centre of scanning head 1
Magnet links "L" Magnet rechts "R"
Limit switch left "L" Limit switch right"R"
3,5
3
2
10
3 0,5
LMB-110/LMB-1150
6. LMKF-110/1150
Scale type LMB-410/4150
Endlageschaltpunkt=Abtastkopfmitte 0,25
Magnet links "L" End position switching point Magnet rechts "R" 1
Limit switch left "L" =centre of scanning head Limit switch right"R"
4,32
8,5
3
14
1 0,5
6
LMB-410/LMB-4150
7. LMK-130
Scale type LMB-130
Endlageschaltpunkt=Abtastkopfmitte
End position switching point
=centre of scanning head LMB-130
1 1
14
1
9
15
16
Sold & Serviced By:
ELECTROMATE
51
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
AMOSIN - Lngenmesssysteme Allgemeine technische Daten
AMOSIN length measuring systems General technical data
8. LMKF-130
Scale type LMB-130
Endlageschaltpunkt = Abtastkopfmitte
End position switching point
=centre of scanning head
1,5
Magnet links "L" Magnet rechts "R" 0,5
Limit switch left "L" Limit switch right "R"
2,5
2x
3
6
14
1 0,5
2 1
9. LMK-310/3150
Scale type LMF-310/3150
Endlageschaltpunkt=Abtastkopfmitte 20
Endlage links "L" End position switching point Endlage rechts "R" 34,5
2x
End position left "L" =centre of scanning head 4,5 10 End position right"R" 31
1 0,5
12
26
4
LMF-310
ELECTROMATE
52 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Allgemeine technische Daten AMOSIN - Lngenmesssysteme
General technical data AMOSIN length measuring systems
Cable
Technical data
Messsystem Verlngerungskabel
Measuring system Extension cable
VK - 4 - - -
10 ..... without connector 00 ..... without connector
11 . .... 12 pin DIN 01 ..... 12 pin DIN
13 ..... 9 pin SUB-D 03 ..... 9 pin SUB-D
14 ..... 12 pin CONNEI connector CW 04 ..... 12 pin CONNEI connector CW
15 ..... 15 pin SUB-D Cable length 05 ..... 15 pin SUB-D
16 ..... 12 pin CONNEI coupling CCW in meter 06 ..... 12 pin CONNEI coupling CCW
19 ..... Special connector or special pin assignments 09 ..... Special connector or special pin assignments
ELECTROMATE
53
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
AMOSIN - Lngenmesssysteme Allgemeine technische Daten
AMOSIN length measuring systems General technical data
PIN 1 2 3 4 5 6 7 8 9 10 11 12
Signal B- 5V-Sensor RI+ RI- A+ A- LL B+ LR 0V 0V-Sensor +5V
Color white red-white pink grey green yellow violet brown black blue blue-white red
Shield on housing
PIN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Signal A+ 0V B+ +5V LR RI- LL A- 0V-Sensor B- 5V-Sensor RI+
Color green blue brown red black gray violet yellow blue-white white red-white pink
Shield on housing
PIN 1 2 3 4 5 6 7 8 9
Signal A- 0V B- RI- A+ +5V B+ RI+
Color yellow blue white gray green red brown pink
Shield on housing
PIN A B C D E F G H J K L M
Signal 0V A+ A- B+ LL RI+ RI- +5V B- LR
Color blue green yellow brown violet pink grey red white black
Shield on housing
The sensor lines 0V sensor and 5V sensor are connected internally to the corresponding supply lines.
In case that the option Limit Switch is not used, it is not allowed to connect the pins LL and LR to the following electronics (for example
controller). These pins serve alone for test purposes only with the AMO testdevice STU-20.
ELECTROMATE
54 Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
Allgemeine technische Daten AMOSIN - Lngenmesssysteme
General technical data AMOSIN length measuring systems
Product overview:
Produktbersicht:
Incremental
LENGTH- AND ANGLE MEASURING Inkrementelle
SYSTEMS based on the AMOSIN LNGEN- UND WINKELMESSSYSTEME
Inductive Measuring Principle nach dem AMOSIN Messprinzip
Inductive encoders comparable
Induktive Messsysteme
to optical encoders in both,
vergleichbar mit optischen
accuracy and resolution
Encodern in Genauigkeit
und Auflsung
No magnetic components, no
magnetic fields, hysteresis or
Keine magnetischen
demagnetisation risk
Komponenten oder Felder,
Hysterese oder Entmagneti-
Protection class IP67
sierungs Gefahr
Fluid submersible encoders
Schutzart IP67
wasserdichte Impulsgeber
Winkelmesssysteme Spindelgeber
Angle measuring systems Spindle encoder
Inkrementelle WINKELMESSSYSTEME
nach dem
induktiven AMOSIN Messprinzip Spindelgeber
nach dem AMOSIN Messprinzip
Incremental ANGLE MEASURING SYSTEMS Spindle encoder based on the AMOSIN
based on the Inductive Measuring Principle
AMOSIN Inductive Measuring Principle
Kompakte Bauform
Compact desig
Hohe EMV-Festigkeit
High EMC immunity
Keine magnetischen
Komponenten oder Felder,
Hysterese oder Entmagneti-
sierungsgefahr
No magnetic components
No magnetic field hystere-
sis or demagnetisation risk
Schutzklasse IP67
wasserdichte Impulsgeber
Protection class IP67
Fluid submersible encoders
Absolute Geber
Absolute encoders
AMO GmbH
Absolutsysteme
nach dem induktiven AMOSIN Messprinzip
Absolute encoder based on the AMOSIN
Inductive Measuring Principle
Verfgbare Schnittstellen:
SSI, BiSS/C, Fanuc
Available interfaces
SSI, BiSS/C, Fanuc
Schutzklasse IP67
Protection class IP67
ELECTROMATE
55
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]
AMO GmbH
ELECTROMATE
Toll Free Phone (877) SERVO98
Toll Free Fax (877) SERV099
www.electromate.com
[email protected]