Sect 1 Technical Data PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

THOM-KATT SERIES AND VS-SERIES WARRANTY

Putzmeister, Inc. trailer-mounted concrete Thom-Katt pumps are designed and


engineered to perform as stated on published specifications. Only quality material and
workmanship are used in the manufacture of these products. With proper maintenance
and periodic service, this equipment will provide excellent service.

Putzmeister, Inc. warrants each new machine to be free of defects in material and
workmanship under normal use and service for a period of twelve (12) months from date
of delivery to initial user, or 1100 pumping hours, whichever comes first.

This warranty is issued only to the initial user and promises that Putzmeister, Inc.
manufactured products are free from defects in material and factory workmanship. Said
warranty is void if the machine is subject to misuse, neglect, accident or abuse. The
warranty period begins when the machine is delivered to the initial user, or when first put
into service, whichever occurs first.

Putzmeisters obligation under this warranty is limited to correcting, without charge, at its
factory, any part or parts thereof which shall be returned to its factory or authorized
distributor, transportation prepaid, and upon examination proves to Putzmeisters
satisfaction to have been originally defective. Correction of such defects by repair or
replacement shall constitute fulfillment of all obligations to the initial user. This
warranty does not include labor or transportation charges nor shall it apply to a machine
upon which repairs or alterations have been made, unless authorized by Putzmeister.

This warranty does not apply to normal maintenance service or to normal replacement of
certain machine parts (such as concrete cylinders, valve mechanisms, delivery systems,
etc.) which are subject to normal wear. Putzmeister makes no warranty in respect to
Engines, trade accessories or outside purchased components, such being subject to the
warranties of their respective manufacturers.

THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR


IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. Putzmeister shall not be liable for loss, damage or
expense directly or indirectly from the use of its products or from any cause. No person,
firm or corporation is authorized to assume for Putzmeister any other liability in
connection with the sale of these machines.

T.D. Set TKAE-E


Hydraulic Schematic: A008234 p. 2 of 2 PUTZMEISTER-RACINE
Date: 11/04/02 Revision: A By: AK 1733 90th Street
Sturtevant, WI 53177
TK40, TK50, KATT-KRETER w/RS400A Phone: (414) 886-3200

Item # Qty. PN Description

101 2 261092006 Hyd. Drive Cylinder 1000-80/45


102 3 044000008 Check Valve, SA5
102a 1 311927 Check Valve, 75psi
102b 1 044153007 Check Valve, SA5
103 1 311997 Shift Control Valve, 12V
105 1 311998 Main Control Valve, 12V
106 1 311976 Main Control Block, Bare
109 2 262840008 Shift Cylinder, 60mm x 160mm
113 1 312776 Pressure Gauge for High Pressure, 0-6000psi
114 1 311658 1-Spool Valve for Remixer (Optional)
114a 1 A023002 2-Spool Valve for Remixer & Water Pump (Optional)
114b 1 A023000 1-Spool Valve for Water Pump (Optional)
115 1 238130001 Hydraulic Motor for Remixer (Optional)
118 1 311680 Accumulator Loading Valve
119 1 312777 Pressure Gauge for Accumulator, 0-3000psi
120 1 311944 Accumulator, 1gallon
121 1 311690 Accumulator Discharge Valve, 12V
123 1 A020042 Volume Control Assembly
127 1 A012029 Main Pump, HA10VO71 (TK40)
. 1 A012030 Main Pump, HA10VO100 (TK50)
. 1 A012031 Main Pump, H-A10VO100 (Katt-Kreter)
128 1 A013016 Gear Pump for Accumulator
129 1 A013017 Gear Pump for Accumulator and Optional Equipment (Optional & Replaces Item 128)
132 1 066368003 Oil Cooler (TK40)
. 1 --- Oil Cooler Engine mounted (TK50 & Katt-Kreter)
133 1 A015022 Return Filter Assembly (Head & Element), 43psi bypass
134 1 311660 Return Filter Element
135 1 A014021 Hydraulic Oil Tank
141a 1 311666 Suction Strainer, 3
141b 1 311808 Suction Strainer, 1.5
142 3 139884 Orifice, 0.031
148 1 A041362 Pressure Gauge, 43psi bypass
150 1 311934 Thermometer and Level Indicator
157 1 067860005 Thermo Probe for Cooler (55C) (TK40)
162 1 311702 Hydraulic Motor for Water Pump (Optional)
165 1 311935 Drain valve
167 2 242591005 Orifice, 1.8mm
168 1 A041403 Orifice, 9.1mm
169 1 311679 Pressure Limiting Valve for Accumulator
175 2 224079008 Orifice, 6mm
182 1 311925 Pressure Limiting Valve
187 1 311638 3-Spool Valve for Hydraulic Outriggers and Remixer (Optional)
187a 1 A023001 2-Spool Valve for Hydraulic Outriggers (Optional)
188 2 A094016 Hydraulic Outrigger Cylinders 2X14 (Optional)
197 1 311719 Alternating Check Valve
200 1 A020040 Main Control Block Assembly
7+( )2//2:,1* &$87,216 '(6&5,%( $33/,&$7,21 $1' ,167$//$7,21 ,1)250$7,21

 '2 127 ,167$// &21752/ &$%/(6 21 $1< $33/,&$7,21 :+,&+ 0$< (;&((' $1<

2) 7+( '(6,*1 3$5$0(7(56 2) 7+( &21752/ &$%/(

 &$%/(&5$)7 &21752/ &$%/(6 $5( '(6,*1(' $1' $66(0%/(6 72 %( 1215(3$,5

$%/( '2 127 $77(037 72 02',)< 7+,6 &21752/ &$%/(

 &$%/(&5$)7 &$%/(6 $5( '(6,*1(' 72 %( &217$0,1$17 5(6,67$17 127 &21

&217$0,1$17 3522) 3527(&7 7+( &$%/( )520 &217$0,1$176 68&+ $6 *$6

2,/ ',(6(/ )8(/ :$7(5 ',57 $1' &+(0,&$/6 :+,&+ 0$< '$0$*( 7+( &21752/

&$%/(

 3527(&7 7+( &21752/ &$%/( )520 3+<6,&$/ '$0$*( %< 3$,17 .,1.,1*

9,%5$7,21 (&7 :+,&+ 0$< '$0$*( 7+( &21752/ &$%/(

 &21752/ &$%/(6 +$9( 7+( %(67 /2$' &$3$&,7< ,1 7+( 38// 02'( $/:$<6

,167$// 7+( &21752/ &$%/( 62 ,7 38//6 7+( *5($7(67 /2$' $1' 386+(6 7+(

60$//(5 /2$' $1' 38//6 7+( ,7(0 ,172 7+( 1(875$/ 25 2)) 326,7,21

 '2 127 ,167$// 7+( &21752/ &$%/( :,7+ 7+( 32:(5 21 25 7+( (1*,1(

5811,1* 6(5,286 ,1-85< 25 '($7+ &28/' 5(68/7

 7+( 6:,9(/ $1*/( 0867 %( &(17(5(' :,7+,1 7+( $9$,/$%/( 6:,9(/

$1*/(

 7+( 86$%/( 75$9(/ 0867 %( &(17(5(' :,7+,1 7+( $9$,/$%/( 6752.(


7+( )2//2:,1* :$51,1*6 '(6&5,%( ,03257$17 386+38// &$%/( 23(5$7,21
$1' 0$,17(1$1&( ,1)250$7,21

 '2 127 $'-867 7+( &21752/ &$%/( :,7+ 7+( 32:(5 21 25 7+( (1*,1(
5811,1* 6(5,286 ,1-85< 25 '($7+ &28/' 5(68/7

 $ *5$'8$/ 25 68''(1 ,1&5($6( ,1 7+( 12/2$' )5,&7,21 &$%/( ',6


&211(&7(' $7 %27+ (1'6 2) $ &21752/ &$%/( ,6 $1 ,1',&$7,21 2) $
3(1',1* 25 35(6(17 3(5)250$1&( 352%/(0 7+( &21752/ &$%/(
6+28/' %( 5(3/$&(' 27+(5:,6( 6(5,286 ,1-85< 25 '($7+ 0$< 5(68/7

 $ *5$'8$/ 25 68''(1 '(&5($6( ,1 7+( 86$%/( 75$9(/ ,6 $1 ,1',&$7,21


2) 3(1',1* 25 35(6(17 3(5)250$1&( 352%/(0 7+( &21752/ &$%/(
6+28/' %( 5(3/$&(' 27+(5:,6( 6(5,286 ,1-85< 25 '($7+ 0$< 5(68/7

 &21752/ &$%/(6 :+,&+ +$9( 02,6785( ,16,'( 2) 7+(0 $1'25 +$9(


)52=(1 6+28/' %( 5(3/$&(' '2 127 $33/< +($7 72 7+$: 2) '5<
&21752/ &$%/(6

 &$%/(&5$)7 &21752/ &$%/(6 $5( /8%5,&$7(' )25 7+( /,)( 2) 7+(


&21752/ &$%/( '2 127 5(029( 7+( 6($/6 25 /8%5,&$7( 7+( &21752/
&$%/(

 &$%/(&5$)7 &21752/ &$%/(6 $5( '(6,*1(' 72 %( 1215(3$,5$%/( '2


127 $77(037 72 5(3$,5 7+,6 &21752/ &$%/(
Putzmeister America
1733 90th Street
Sturtevant, WI 53177
Tel. (262) 886-3200
Fax (262) 886-3212

WARRANTY REGISTRATION / IN-SERVICE INSPECTION


This warranty registration and in-service inspection form must be completed and returned
to Putzmeister America Inc., within fifteen (15) days of the purchase or the in-service date
of the unit. Failure to return this form as instructed may void warranty. Warranty claims
may not be processed until the unit has been properly registered and inspected.

COMPLETED BY PUTZMEISTER AUTHORIZED DISTRIBUTOR

Distributor: ______________________________________________________

Address: ________________________________________________________

City: ___________________________ State: _________ Zip: ____________

Phone: (____)___________________________

Model: _______________ Serial Number: ____________________________

Date Unit Received: ______________ Date Placed In Service: ___________

Hour Meter Reading: _____________

COMPLETE LOWER SECTION IF UNIT IS SOLD

Owner: _________________________________________________________

Address: _______________________________________________________

City: ___________________________ State: _________ Zip: ___________

Phone: (___)_________________ Person to Contact: __________________

Date Delivered: _______________ Date Placed In Service: _____________

Hour Meter Reading: _____________