Solenoid Valves 3/2 327: No Voltage Release (Tamperproof)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

SOLENOID VALVES 3/2

2
no voltage release (tamperproof) Series
U
manual reset construction 1 3 327
1/4
FEATURES

ASCO/JOUCOMATIC solenoid valves satisfy all relevant EC Directives


Compact Tamperproof/Manual Reset function which means that the valve has to be
energized as well as manually operated before it stays in the "latched" position.
Because of the tamperproof feature there will be no flow from port 3 to port 2 if only
the push button is pressed. The No Voltage Release (NVR) function will make sure
that the valve trips when de-energized
The solenoid valves are recommended for pilot applications with high flow, wide
pressure ranges and no minimum operating pressure
The core is guided by means of a riderring and special low friction seal with a modi-
fied PTFE sealing surface in order to accomplish a balanced construction of the valve
at the full specified temperature and pressure range with a minimum consumption of
electrical power
No minimum operating pressure is required

GENERAL
Differential pressure 0 - 10 bar [1 bar = 100kPa]
Maximum viscosity 65cST (mm2/s)
Response times 75 - 100 ms

fluids (!) temperature range (TS) seal material (!)


1
2
air, inert gas, water, oil -20 to + 80C NBR (nitrile / buna-n) 3
-20 to +120C FPM (fluoroelastomer / viton)

MATERIALS IN CONTACT WITH FLUID


!) Ensure that the compatibility of the fluids in contact with the materials is verified
(!
Brass body Stainless steel body
Body Brass AISI 316 SS
Stem Stainless steel Stainless steel
Core tube Stainless steel Stainless steel BP
Core and plugnut Stainless steel Stainless steel MP
Springs Stainless steel Stainless steel
Sealings & poppets NBR FPM RP
Riderring PTFE (teflon) PTFE (teflon) LP
Not
Available 3,6W - 3,7W 5,7W - 5,8W 10,0W -11,2W

Low Reduced Medium Basic


power power power power

POWER LEVELS - cold electrical holding values (watt)

SPECIFICATIONS
flow operating pressure
coefficient Prefix optional solenoids basic
pipe orifice differential (bar) power
Kv catalogue
size size min. max. (PS) level NEMA ATEX/CENELEC
port IP65 number
12 2 3 1 2 2 3 air/water (!) 7&9 EExd EExem EExm EExn
" (mm) (m3/h) (l/min) ~\= EF ~\= NF/NL EM PV ZN SC brass stainless st.
U - Universal, NBR or FPM sealings and poppets, manual reset
1/4 5,7 0,52 0,62 8,70 10,30 0 10 BP # # # $ $ # " 327A021 " 327A022
1/4 5,7 0,52 0,62 8,70 10,30 0 10 MP - # # - - # " 327A221 " 327A222
1/4 5,7 0,52 0,62 8,70 10,30 0 10 RP - # # - - # " 327A121 " 327A122
U - Universal, NBR or FPM sealings and poppets, manual reset tamperproof
1/4 5,7 0,43 0,49 7,17 8,17 0 10 BP # # # $ $ # " 327A031 " 327A032
1/4 5,7 0,43 0,49 7,17 8,17 0 10 MP - # # - - # " 327A231 " 327A232
1/4 5,7 0,43 0,49 7,17 8,17 0 10 RP - # # - - # " 327A131 " 327A132
" Select B for NPT ANSI 1.20.3 Available feature
2004/R01

Select G for ISO G(228/1) $ Available feature in DC only


- Not available
All leaflets are available on: www.ascojoucomatic.com

PIC-11-20-GB
SERIES 327
PREFIX TABLE PRODUCT SELECTION GUIDE
prefix description power level STEP 1
1 2 3 4 5 6 7 LP RP MP BP Select basic catalogue number,
S C D U Dustproof ATEX (EN 50281-1-1) * - # # # including pipe thread indentification
E F Explosionproof - NEMA 3, 4, 6, 7, 9 - - - # letter. Refer to the specifications table
E V Explosionproof - NEMA 3, 4, 6, 7, 9 - 316 SS - - - # on page 1.
E M Encapsulated ATEX (EN 50019 & EN 50028) * - # # # Example: B327A021
E T Threaded conduit/hole (M20 x 1.5) - # # #
I S S C Intrinsically safe with SC coil ATEX (EN 50020) * - - - - STEP 2
N F Flameproof - Alum. ATEX (EN 50018) * - # # #
Select prefix (combination). Refer to
N L Flameproof - Cast Iron ATEX (EN 50018) * - # # #
Encapsulated ATEX (EN 50028) * - - - $ the specifications table on page 1 and
P V
S C Solenoid with spade plug connector (EN 60730) - # # # the prefix table on page 2, respect the
W P Waterproof IP67 - Metal enclosure (EN 60730) - # # # indicated power level.
W P D U Dustproof ATEX (EN 50281-1-1) - Metal enclosure * - # # # Example: SC
W P I S I.S. with Metal IP67 enclosure ATEX (EN 50020) * - - - -
W S Waterproof IP67 - 316 SS enclosure - # # # STEP 3
W S D U Dustproof ATEX (EN 50281-1-1) - 316 SS enclosure * - # # # Select suffix (combination) if required.
W S E M 316 SS "EM" enclosure ATEX (EN 50019 & EN 50020) * - # # # Refer to the suffix table on page 2,
W S I S I.S. with 316 SS IP67 enclosure ATEX (EN 50020) * - - - - respect the indicated power level.
W S N F Flameproof - 316 SS ATEX (EN 50018) * - # # #
Example: VCO
T Threaded conduit (1/2" NPT) - # # #
H C Class H - Battery charging circuit - - - #
#
STEP 4
H T Class H - High temperature - # #
- - $ Select voltage. Refer to standard
Z N Encapsulated Non Sparking ATEX (EN 50021)* -
X Other special constructions - # # # voltages on page 3.
Example: 230V / 50Hz
SUFFIX TABLE
STEP 5
suffix description power level
Final catalogue / ordering number.
1 2 3 4 5 LP RP MP BP
Example:
E Ethylene - Propylene (EPDM) - - - - SC B327A021 VCO 230V / 50 Hz
J Neoprene (CR) - - - -
N Oxygen service (Neoprene (CR)) - - - -
N V Viton (FPM) parts cleaned for oxygen service - # # #
V Viton (FPM) - # # #
C O Epoxy coating all external surfaces - # # #
M B Mounting bracket - - - -
P Dry gas, non-lubricated air construction - - - -
Q Long life, quiet operation construction - - - -
M O Manual operator - - - -
M S Screw type manual operator - # # #
M Metering device - - - -

Available feature
$ Available feature in DC only ORDERING EXAMPLES VALVES:
- Not available
* ATEX solenoids are also approved according to EN 50281-1-1 (dust) and EN 13463-1 SCHT B 327A021 24V / DC
(non electrical valves) WSEMT G 327A022 CO 24V / DC
NFET G 327A021 V 230V / 50 Hz
WSEM G 327A022 24V / DC
NF B 327A231 CO 24V / DC
WS G 327A021 CO 24V / DC
EM B 327A221 V 230V / 50 Hz
OPTIONS & ACCESSORIES PV B 327A032 CO 24V / DC
EF G 327G122 CO 240V / 60 Hz
(1)
catalogue spare parts kit no. mounting
number ~ = bracket no. prefix (2) voltage
pipe thread suffix
SC "327A021 C123-669 C123-669 %
basic number (2)
SC "327A022 C123-670 C123-670 %
SC "327A031 C131-236 C131-236 %
SC "327A032 C131-237 C131-237 % ORDERING EXAMPLES KITS:
SC "327A121 C132-250 C132-250 %
SC "327A122 C132-251 C132-251 % C123-669 (3)
SC "327A131 C132-252 C132-252 % PV C123-670
SC "327A132 C132-253 C132-253 % NF C123-669 V
SC "327A221 C132-250 C132-250 % WSEM C123-670
SC "327A222 C132-251 C132-251 %
"327A231 % prefix suffix
SC C132-252 C132-252
SC "327A232 C132-253 C132-253 % basic number
" (2)
2004/R01

Select B for NPT ANSI 1.20.3 or select G for ISO G(228/1) Prefix EF and EV should always be used in conjunction with
(1)
Standard prefixes/suffixes are also applicable to kits change letter G in the basic number
% Mounting holes in body (3)
Basic kit number applies to SC coil construction
All leaflets are available on: www.ascojoucomatic.com

11-20-2
SERIES 327
ELECTRICAL CHARACTERISTICS

Coil insulation class F


Connector Spade plug
Connector specification ISO 4400 (cable 6-10 mm)
Electrical safety IEC 335

Standard voltages: DC (=) 24V - 48V


AC (~) 24V - 48V - 115V - 230V/50Hz; Other voltages and 60Hz are available on request
power ratings operator electrical
replacement coil / kit
prefix inrush holding hot/cold amb. temp. enclosure
safety code type (2)
option ~ ~ = range (TS) protection ~ =
(VA) (VA) (W) (W) (C) (1) (EN 60529) 230V/50Hz 24V/DC
Basic power (BP)
SC 10,0 10,0 10,0 9,0/11,2 -40 to +55 EN 60730 moulded IP65 123-664-017 400-425-142 01
WP/WS 10,0 10,0 10,0 9,0/11,2 -40 to +55 EN 60730 steel IP67 400-915-017 400-405-142 03
(WS)NF/NL 10,0 10,0 10,0 9,0/11,2 -60 to +40/60 II 2 G/DEEx d IIC T6/T5 alu/steel IP67 400-915-017 400-405-142 05
EM/WSEM 10,0 10,0 10,0 9,0/11,2 -40 to +40 II 2 G/D EEx em II T3 steel IP67 400-915-017 400-913-142 03
PV - - - 9,0/11,2 -40 to +65 II 2 G/D EEx m II T3(~)/T4(=) moulded IP65 - - (4) 06
EF 10,0 10,0 10,0 9,0/11,2 -40 to +55 NEMA type 7 and 9 NEMA 4X - 238-714-006D 07
ZN - - - 9,0/11,2 -20 to +50 II 3 G/D EEx nA II T3 moulded IP65 - - (4) 01
Medium power (MP)
SC 5,8 5,8 5,8 5,2/5,7 -40 to +90 EN 60730 moulded IP65 400-924-297 400-923-442 02
WP/WS 5,8 5,8 5,8 5,2/5,7 -40 to +90 EN 60730 metal IP67 400-911-297 400-911-442 04
(WS)NF/NL 5,8 5,8 5,8 5,2/5,7 -60 to +60/75/90 II 2 G/D EEx d IIC T6/T5/T4 alu/steel IP67 400-921-297 400-911-442 05
EM/WSEM 5,8 5,8 5,8 5,2/5,7 -40 to +40/75/90 II 2 G/D EEx em II T5/T4/T3 metal IP67 400-921-297 400-914-442 04
Reduced power (RP)
SC 3,7 3,7 3,7 3,5/3,6 -40 to +55 EN 60730 moulded IP65 400-924-098(3) 400-923-042 02
WP/WS 3,7 3,7 3,7 3,5/3,6 -40 to +55 EN 60730 metal IP67 400-921-098(3) 400-911-242 04
(WS)NF/NL 3,7 3,7 3,7 3,5/3,6 -60 to +60 II 2 G/D EEx d IIC T6 alu/steel IP67 400-921-098(3) 400-911-242 05
EM/WSEM 3,7 3,7 3,7 3,5/3,6 -40 to +40/55/60 II 2 G/D EEx em II T6/T5/T4 metal IP67 400-921-098(3) 400-914-242 04
(1) (2) (3)
Temperature range can be limited by sealings Refer to the dimensional drawings on page 4 and 5 AC (~) limited to 115V/50Hz - Not available
(4)
Multiple coil-kits available under ATEX, consult ASCO/JOUCOMATIC

ADDITIONAL OPTIONS
3/8" pipe thread executions are available (NPT only)
EEx m (prefix "PV") solenoid can be supplied in various cable lengths
Compliance with "UL", "CSA" and other local approvals available on request
1/2" NPT (prefix "T") and M20 x 1,5 (prefix "ET") conduits (aluminium or 316 SS) available for steel solenoid housings
Special moulded-in solid state components for peak voltage suppression and/or rectification (four diode bridge)
Manual Reset constructions suitable for -40C are available on request

INSTALLATION

Multi language installation/maintenance instructions are included with each valve


The solenoid valves can be mounted in any position without affecting operation
The mounting holes are provided in the valve body
Threaded pipe connection identifier is B = NPT (ANSI 1.20.3); G = G (ISO 228/1)
Declarations of conformity are available on request
EEx em (prefix "EM") execution: solenoid enclosure has a cable gland with integral strain relief for cables with an o.d.
from 7 to 12 mm and is provided with an internal and external connection facility for an earthing or bonding conductor
EEx d (prefix "NF") enclosure is provided with a 1/2" NPT (prefix "T") threaded entry hole M20 x 1,5 (prefix "ET") optional
and is supplied without cable gland
Valves with suffix "SL" should be provided with a specific exhaust protector
2004/R01

All leaflets are available on: www.ascojoucomatic.com

11-20-3
SERIES 327
DIMENSIONS (mm), WEIGHT (kg)
TYPE 01: TYPE 02:
Prefix "SC" / "ZN" Solenoid Prefix "SC" Solenoid
Basic power Reduced and medium power
Epoxy moulded Epoxy moulded
IEC 335 / ISO 4400 (SC) IEC 335 / ISO 4400
EN 50021 (ZN) IP65
IP65 / II 3 G/D EEx nA II
327A021 / A022 /A031 / A032 327A121 / A122 / A131 / A132 / A221 / A222 / A231 / A232
A G F
H G
J A H
K J

360 360
N M
D D
F
E E
C 5.5
12 23 C 5.5
12 23

27 27
41 41
B L M B K L

TYPE 03: TYPE 04:


Prefix "WP", "WS" / "EM", "WSEM" Solenoid Prefix "WP", "WS" / "EM", "WSEM" Solenoid
Basic power Medium and reduced power
Steel; epoxy coated (WP and EM) Steel; epoxy coated (WP and EM)
AISI 316 SS (WS and WSEM) AISI 316 SS (WS and WSEM)
IEC 335 / EN 50019, EN 50028 and 50281-1-1 IEC 335 / EN 50019, EN 50028 and 50281-1-1
IP67 / II 2 G/D EEx em II IP67 / II 2 G/D EEx em II
327A021 / A022 /A031 / A032 327A121 / A122 / A131 / A132 / A221 / A222 / A231 / A232
A F A F
G G

360 360
D K K
D

E E
C 5.5 C 5.5
12 23 12 23

27
41
B H J B H J

TYPE 05: TYPE 06:


Prefix "NF", "NL" and "WSNF" Solenoid Prefix "PV" Solenoid
Basic, medium and reduced power Basic power
Aluminium, steel; epoxy coated (NF and NL) Epoxy encapsulated
AISI 316 SS (WSNF) EN 50028 and EN 50281-1-1
EN 50018 and EN 50281-1-1 II 2 G/D EEx m II
IP67 / II 2 G/D EEx d IIC IP65
327A021 / A022 / A031 / A032 / A121 / A122 / 327A001 / A002 /A011 / A012
A131 / A132 / A221 / A222 / A231 / A232
A E A F
F G
1/2 NPT 9 H

15 L
L D
D
E
HJ C 5,5
12
23
C 5,5
12 23

B 27 K
B 27 K 41
2004/R01

41
G J

All leaflets are available on: www.ascojoucomatic.com

11-20-4
SERIES 327
DIMENSIONS (mm), WEIGHT (kg)
TYPE 07:
Prefix "EF" Solenoid
Basic power
Epoxy encapsulated
ICS-6 ANSI / NEMA
Type 7 and 9
NOTE: applicable to solenoid only
327G021 / G022 / G031 / G032
A F
G

K
D

E
C 5,5
12 23

B 27 J
41
H

type prefix option power A B C D E F G H J K L M N weight


level
01 SC/ZN basic power 45 30 24 79 138 155 91 85 50 30 55 27 67 1,20 kg
02 SC medium/reduced power 50 30 24 98 149 95 91 56 33 55 27 86 - 1,30 kg
03 WP/WS/(WS)EM basic power 77 30 24 98 155 120 81 55 27 86 - - - 1,20 kg
04 WP/WS/(WS)EM medium/reduced power 77 30 24 101 158 120 81 55 27 89 - - - 1,30 kg
05 NF basic/medium/reduced power 97 30 24 125 102 54 55 88 176 27 113 - - 2,70 kg
06 PV basic power 45 30 24 86 137 72 67 45 55 27 74 - - 1,20 kg
07 EF basic power 50 30 24 87 138 77 51 55 27 75 - - - 1,20 kg

SECTIONAL DRAWING

1
2

Execution : Reduced Power Tamperproof


2004/R01

All leaflets are available on: www.ascojoucomatic.com

11-20-5
11-20-6
All leaflets are available on: www.ascojoucomatic.com
SERIES 327

PIC-11-0020-GB -- ASCO/JOUCOMATIC reserves the right to alter the availability, design and specifications without notice.
2004/R01

You might also like