Reaffirmed 2000
Reaffirmed 2000
Reaffirmed 2000
Indian Standard
SPECIFICATION FOR
MORTICE LATCH (_VERTICAL TYPE)
Memkers
SRRI Saar~ Srwo~ ( Alternate to
Shri Yusuf Mowjee )
SHRI AJJOYEXDU PAUL Gobindo Sheet Metal Works and_Poundry, Calcutta
SHRI P. L. BHASIN Engineer-in-Chiefs Branch, Army Headquarters
Sam A. K. BHZMANI The Vertex Manufacturing Co Pvt Ltd, Bombay
SRRI H. C. SAXPAT ( Alternate )
SHEI R. M. CEAUDRRI Indian Aluminium Co Ltd, Calcutta
SHRI J. K. ANAND ( Alternate)
LT-COL H. S. CRHACHHIA Defence Production Organization ( Ministry of
Defence )
SHRY L. P. MATHDR ( Alfanate)
CONTRCILLEX OF STORES, EABTERH Railway Board ( Ministry of Railways )
RAII,WAH
SHRI R. L. GEHLCWE The Intiiau Institute of .i\rchitects, Bombay
SRRI v, S. bXRO,_ jayna Trading Corporation, New Delhi
Srrm s. C. K;A^POOR Directorate General of Supplies & Disposals
Sirm S. D. M~~c-hfn~n National Test House, Aiipore
Smu YUSUP MOWJEX Builders Hardware Industries Association of India,
Calcutta
DR A. V. R. RAO National Buildings Organisation, New Delhi
ASBISTANT DIRECTOR, MECAA.-
NICAL i%Olh~m ( Alternate )
REPRESEKTATIVE Des Lock Industries, Calcutta
REPRESENTATIVE Institution of Engineers ( India ), Calcutta
SHRI D. AJITHA SIXHA, Director General, IS1 ( Ex-o&o Memker)
Director ( Civ Engg )
Secretary
SHRXV. K. GO~NA
Deputy Director ( Architecture ), IS1
( Continued on page 2 )
( Confinudfrom pogc 1)
GWWtl.9 Representing
Members
SHRI K. c. MSRA ( Alternate to
Shri J. R. Sachdeva)
Directorate of Industries, Government of West
2
IS : 5930 - 1970
hdian Standard
SPECIFICATION FOR
MORTICE LATCH ( VERTICAL TYPE )
0. FOREWORD
0.1This Indian Standard ~was adopted by the Indian Standards Institu-
8.6 This standard contains clauses 2.2, 7.2, 8.1 and 9.1.1which permit the
purchaser to use his option for selection to suit his requirements. It also
Contains clause 4.1 which permits the manufacturer to change the shape
and mechanism of mortice latch to suit a particular design.
8.7 For the purpose of deciding whether a particular requirement of this
standard is complied with, the final value observed or calculated, express-
ing the result of a test or analysis, shall be rounded off in accordance
with IS : 2-1960*. The number of significant places retained in the
rounded off value should be the same as that of the specified value in this
standard.
3
IS:5930-1970
1. SCOPE
1.1 This standard lays down the requirements for mortice latches for use
on doors, such as bathroom doors, W. C. doors and doors to private rooms.
2. SIZE
2.1 The sizes of the mortice latch for bathroom and W. C. doors shall
be as follows:
65 mm. 76 mm and 100 mm
X1.1 The size of the latches shall be denoted by the overall length of
5. DIMENSIONS
5.1 The leading dimensions of the mortice latches shall be normally as
given in Fig. 1.
6. INTERCHANGEABILITY
6.1 The component parts of all latches of the same size and type shall be
completely interchangeable. For the purpose of ascertaining the require-
ments, the sampling scheme indicated in 12 shall be followed.
7. MANUFACTURE
i.1 Body -The depth of the body shall not be more than 15 mm.
7.2 Fore End-The case plate itself may form the fore end. However,
where so desired by the purchaser, in order to obtain a clean plate free
from rivets and to assist in decorating the fore end a face plate may be
provided. The fore end shall be firmly fitted to the body by suitable
countersunk head machine screws conforming to IS: 1365-l-968* or any
other suitable device.
*Specification for slotted countersunk head and slotted raised countersunk head saeWS
( &a range 1.6 to 20 mm ) ( secondrevision).
IS : 3936 9 1970
5
SUPPLIED BY BOOK SUPPLY BUREAU TO L&T LIMIED ECC DIVISION
UDYOG VIHAR GURGAON FOR INTERNAL USE AT THIS LOCATION ONLY
9
OL6l-066S:SI
.
9%
Ll I ? FOLLOWER
6s SQUARE
HOLE
li+zILJD
6 LATCH BOLT
II
U
3 LATCH SPRING
5 LOCKING LUG
@ -1.5 MN
4 LEVER
7 LOCKING BOLT
,g
tz
o--- 25.-
1 CASE PLATE p
All dimensions in millimetres.
0
FIG. 1 TYPICAL DESIGN OF MORTICX LATCH (VERTICAI. TYPE)
TABLE 1 MATERIALS FOR VARIOUS COMPONENT PARTS OF MORTICjE LATCHES
( Clauses 3.1, 7.3, 7.5 and 7.9 )
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14)
9
TABLE 2 REQUIREMENTS FOR MATERIAL FOR MORTICE LATCHES
m
i) Mild steel Grade 0 of IS : 1079-19681 Finished components shall satisfy the following bend test:
The component part when cold shall withstand, without
developing cracks being doubled over either by pressure or by
blows from hammer until the internal radius is equal to the
thickness of diameter of the component part and the sidea
are parallel
iv) Extruded brass IS : 319-1968s Copper contents shall not be less than 55 percent and tensile
strength 35 kgjmms, Min
v) Brass sheet Grade BS 60 of IS : 410-1967s The brass sheet shall meet the same bend teat as specified for
mild steel
vi) Brass wire IS : 2704-1964 Copper contents shall not be less than 55 percent and tensile
strength 35 kg/mm, Min
vii) Phosphor bronze PCUSN 4 of IS : 1385-1968 The wire used for spring shall comply with the test below:
wire The lever spring shall be fitted into the lever as specified
under 7.5.1 and shall be pressed down so as to touch the top
edge of the lever and released. This shall be repeated crix
times. At the end of the test the spring shall regain its
original position
SUPPLIED BY BOOK SUPPLY BUREAU TO L&T LIMIED ECC DIVISION
UDYOG VIHAR GURGAON FOR INTERNAL USE AT THIS LOCATION ONLY
viii) StceJ wire Grade2 d 1S : W4-1!W7 The wire used fnr springs shall comply with dje t~t given
I,f:lr)w:
Jhe lever spring sM1 be fitted into the lever .m q~ecified
Ul>dnr7.5.1 and Sh:ll{ !)(: Iwl!isc!.\ &~,) ~> is 1,> touch lhr? top
cdcc SJI the Ievcr ml rclcnwd. Ihij shall be repcatsd !ix
!illlm. At the end of the test the spring shall regain }t$
orlg]t]al pmitiml
ix) baded tin btwoze
W~ifscation for hot rolled mwbon slcel sheet wsd strip ( .wmd rcri~im ).
Tspecification for blackhearr malle~blc irots casiings.
Specification for }nasa ingots and cwstings f rsuiwd ),
%ptwificatims for free-culling tws.. rods awl aeclimu ( mcmd rtwiritw}.
a~pccitlcatism for rolled brass plate, sfscwt, strip and foil ( .wonrf rmitiwr ).
Specification for braw wire fcr cold-headed and machined parts,
Specification for phosphor brcmzc rods and bm~, sheet mttl strip. rmd wirv.
%pccificat ion for steel wires for tYJld formkd sprmgri.
~f$pecifica !ionfor leaded t in lmmzeingotsand c~tings ( rmiseri), z
..
lQSpecjficatirxi for zinc base alloy die castings (./irrl rfst.rim ).
1;Specificatiofl ff,r ~ltJtllini ,Im and ~~wni,lium ~I~v illg,ot~ ~n(] rlht il)ws frjrgEne~4\ engineering purposes ( rtrij~d ). ~
l~fjwcificatioll for ~rough t ~ltlmjnium &ld a]lilini~l~ all,jy~, ~hccl and :triP ( f{,r g~nera] aginmring purposes ) ( ~eui$cd). ~
t
l*Specification fm wrought alumiuiun~ and al nmirrjum alloys, rivet stock ( for general cngiwwing Purimm ) ( r~(~sfd).
MSpe~ifi@tion for zinc plating. z
8
1
STEEL BAR 75cm
LONG APPROX
11. PACKING
11.1 Eac!i mort!ce latch &al! be :vrapped in a paper and packed in a
cardboard box. Each cardboard box should be marked with the following
information:
a) Manufacturers name or trade-mark,
b) Type of latch,
c) Size of latch,
d) Quantity in the package, and
e) Country of origin.
12
IS : 5930 - 1970
(1) (4 (3)
up to 200 15 0
201 9, 300 <: 20 1
301 ,, 500 30 .2
501 9, 800 40 2
801 and above 50 3
12.1.3 Latches for the sample shall be selected at random from at least
10 percent of the packages subject to a minimum of three packages, equal
number of latches being selected -from each such package.
13
SUPPLIED BY BOOK SUPPLY BUREAU TO L&T LIMIED ECC DIVISION
UDYOG VIHAR GURGAON FOR INTERNAL USE AT THIS LOCATION ONLY