100% found this document useful (3 votes)
2K views2 pages

Wind Load Calculation (Based On CP3)

The document calculates wind loads on a curved shade structure based on wind speed data and coefficients from CP3. It determines a basic wind speed of 45 m/s, then calculates a design wind speed of 27 m/s accounting for topography, ground roughness, and statistical factors. It finds maximum and minimum wind pressure coefficients of +0.3 and -0.6. The downward and uplift design wind pressures are 0.134 kN/m^2 and 0.268 kN/m^2. Finally, it calculates the uniform downward and uplift loads on each frame as 0.184 kN/m and 0.368 kN/m, defining two load cases.

Uploaded by

Darshan Shah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (3 votes)
2K views2 pages

Wind Load Calculation (Based On CP3)

The document calculates wind loads on a curved shade structure based on wind speed data and coefficients from CP3. It determines a basic wind speed of 45 m/s, then calculates a design wind speed of 27 m/s accounting for topography, ground roughness, and statistical factors. It finds maximum and minimum wind pressure coefficients of +0.3 and -0.6. The downward and uplift design wind pressures are 0.134 kN/m^2 and 0.268 kN/m^2. Finally, it calculates the uniform downward and uplift loads on each frame as 0.184 kN/m and 0.368 kN/m, defining two load cases.

Uploaded by

Darshan Shah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

WIND LOAD CALCULATION

(Based on CP3)

BASIC WIND SPEED

Basic wind speed, V = 45 meter/sec

DESIGN WIND SPEED

Design wind speed, Vs = VxS1xS2xS3

Where, S1 = Topographical Factor


= 1

S2 = Ground Roughness/Building Factor


= 0.6 (For ht. 3m & Class B building)

S3 = Statical Factor
= 1

Design wind speed Vs = 45x1x0.6x1


= 27 meter/sec

Dynamic wind pressure, q = 0.613xVs2


= 0.613x272
= 447 N/mm2
= 0.447 kN/mm2

WIND PRESSURE CALCULATION FOR CURVED SHADE

FromCP3 Chapter V: Part2, For monopitch canopies, for solidarity ratio 0,

Maximum wind pressure coeff. = +0.3

Minimum wind pressure coeff. = -0.6

DESIGN WIND PRESSURE

Design wind Pressure = +ve Cpe x q


= 0.3x0.447
= 0.134 kN/m2

Design wind Uplift = -ve Cpe x q


= -0.6x0.447
= 0.268 kN/m2
DESIGN WIND LOAD ON FRAME

Frame spacing = 5.5m c/c

Loading area for each side = (5.5x5.5)/4


= 7.563 m2

Downward Load on each frame = 7.563x0.134


= 1.013 kN

Load as UDL = 1.013/5.5


= 0.184 kN/m

Uplift load on each frame = 7.563x0.268


= 2.027 kN

Load as UDL = 2.027/5.5


= 0.368 kN/m

LOAD CASES

Load case 1 (LC1), Wind Pressure = 0.184 kN/m

Load case-2 (LC2), Wind Uplift = 0.368 kN/m