The NPSH called as the Net Positive Suction Head is a necessary calculation whenever
an installation of a pump is designed in order to prevent cavitation for safe and reliable
operation of the system.
The suction gauge is defined as the absolute feet taken on the suction nozzle corrected
to pump centerline, minus the Vapor Pressure in feet absolute corresponding to the tem-
perature of the liquid, plus Velocity Head at this point. There are two conditions to calcu-
late an NPSH pumping system, as described below:
NPSHa: Called as Available Net Positive Suction Head is the normal operation head
determined during design and construction or determined experimentally from a physical
system.
NPSHr: Called as Required Net Positive Suction Head is the maximum head required
by the pump in order to prevent cavitation for safe and reliable operation of the pump.
Generally is determined experimentally by the pump manufacturer and is part of the doc-
umentation of the pump with a graphic named pump curve as the example below.
Note: The available NPSHa of the system should always exceed the required NPSHr of the
pump to avoid vaporization and cavitation of the impellers and pump inner walls. The
NPSHa is also calculated to avoid that head loss in the suction pipe and in the pump cas-
ing, local velocity accelerations and pressure decreases, start boiling the fluid on the im-
peller surface.
Jurandir Primo 2 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
Obs.: Note that the required NPSHr increases with the square capacity. Pumps with dou-
ble-suction impellers have lower NPSHr than pumps with single-suction impellers. A pump
with a double-suction impeller is considered hydraulically balanced but is susceptible to
an uneven flow on both sides with improper pipe-work. The terms commonly used to cal-
culate the NPSH in pumping systems are:
2. STATIC HEAD:
Static head: Is measured from the liquid level to the centerline of the pump. If the liquid
level is above the pump centerline you will have a positive number. If the level is below
the centerline you will have a negative number.
3. PRESSURE HEAD:
Atmospheric pressure: Is 14.7 psi at sea level to be converted to feet, using a for-
mula to the static head where ever you have an open tank. If the fluid is under vacuum
we can convert to the absolute pressure reading to head instead of atmospheric pressure.
Vacuum is often read in inches of mercury so you will need a formula to convert it to
head. Here is the formula:
Total Dynamic Head: Is the vertical distance between the source of supply and the
point of discharge when pumping at required capacity increases the velocity head, fric-
tion, inlet and exit losses, divided in two conditions: Total Dynamic Discharge Head is
the Total Dynamic Head minus Total Dynamic Suction Head.
a. Total Dynamic Discharge Head: Is determined on tests where Suction Head exists.
It is the reading of the gauge attached to the discharge nozzle of pump, minus the read-
ing of a gage connected to the suction nozzle of pump, plus or minus vertical distance
between centers of gauges (depending upon whether suction gage is below or above dis-
charge gage), plus excess, if any, of the Velocity Head of discharge over Velocity Head of
suction as measured at points where instruments are attached.
b. Total Dynamic Suction Head: Is also determined on tests where Suction Head exists
and also divided in three conditions:
1. SUCTION LIFT:
a. Suction Lift: Exists when the suction is measured at the pump nozzle and then cor-
rected to the centerline of the pump, below atmospheric pressure.
Jurandir Primo 3 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
b. Static Suction Lift: Is the vertical distance from the free level or source of the supply
system, to the center line of a pump.
c. Dynamic Suction Lift: Is also determined on tests, is the reading of the mercury col-
umn connected to suction nozzle of pump, plus vertical distance between point of at-
tachment of mercury column to centerline of pump, plus head of water resting on mercu-
ry column, if any.
2. SUCTION HEAD:
a. Suction Head: Exists when the pressure measured at the suction nozzle and then cor-
rected to the centerline of the pump is above the atmospheric pressure (sometimes also
called Head of Suction).
b. Static Suction Head: Is the vertical distance from the free level of the source of sup-
ply to centerline of pump.
c. Dynamic Suction Head: Is the vertical distance from the source of supply, when
pumping at required capacity, to centerline of pump, minus Velocity Head, entrance, fric-
tion, but not minus the internal pump losses.
Note: The Dynamic Suction Head, determined by tests, is the reading of a gage connect-
ed to suction nozzle of pump, minus vertical distance from center of gage to centerline of
pump. The Suction Head, after deducting the various losses, may be a negative quantity,
in which case a condition equivalent to Suction Lift will prevail.
3. VELOCITY HEAD:
The Velocity Head: Sometimes also called as "Head due to Velocity" of water with
a given Velocity, is the equivalent head through which it would have to fall to acquire
the same Velocity: or the head merely necessary to accelerate the water. Knowing the
velocity, we can readily figure the Velocity Head from the simple formula:
v2
h= =
2. g
Where "g" is acceleration due to gravity 9.80665 m/s2 (~32.1740 ft/s2) or knowing the
head (h). And thus obtain the velocity head:
v = 2.g. h
Obs.: The Velocity Head is a factor figuring the Total Dynamic Head, but the value is
usually negligible; however, it should be considered when the Total Head is low and when
the Suction Lift is high. Where the suction and discharge pipes are the same size, it is
only necessary to include in the Total Head the Velocity Head generated in the suction
piping.
If the discharge piping is of different size than the suction piping, which is often the ease,
then it will be necessary to use the Velocity in the discharge pipe for computing the Ve-
locity Head rather than the Velocity in the suction pipe.
Jurandir Primo 4 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
In testing a pump, a vacuum gauge or a mercury column is generally used for ob-
taining Dynamic Suction Lift. The mercury column or vacuum gage will show the Veloc-
ity Head combined with Entrance Head, Friction Head, and Static Suction Lift.
On the discharge side, a pressure gage is usually used, but a pressure gage will not indi-
cate the Velocity Head and therefore be obtained either by calculating the Velocity or tak-
ing readings with a Pitometer.
The Velocity varies considerably at different points in the cross section of a stream. It is
important in using the Pitometer to take a number of readings at different points in the
cross section.
Static Suction Head (H): Is positive when liquid line is above pump centerline and
negative when liquid line is below pump centerline, as can be seen at the sketch below.
Jurandir Primo 5 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
Note: See the tables indicating the energy loss due friction for water flow through
ASME/ANSI B36.10 schedule 40 steel piping and fittings. The friction loss can be
also calculated by, f (loss) = K x v/2g (g = 32.17 ft/s).
Water Vapor
Temperature
Pressure
F C psia
40 4.4 0.1217
50 10 0.1781
60 15.6 0.2563
70 21.1 0.3631
80 26.7 0.5069
90 32.2 0.6982
140 60 2.889
Jurandir Primo 6 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
Viscosity: Is the internal friction of a liquid tending to reduce flow. Viscosity is defined
by instruments termed as Viscosimeters of which there are several types as Saybolt
Universal and Redwood.
Obs.: In the United States the Saybolt Universal is in general use with few exceptions.
Viscosity is expressed as the number of seconds required for a definite volume of fluid
under an arbitrary head to flow through a standardized aperture at constant temperature.
Jurandir Primo 7 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
5. SPECIFIC GRAVITY:
Specific Gravity (S.g): Is the ratio of the weight of any volume to the weight of an
equal volume of some other substance taken as a standard at stated temperatures. As
an example, for solids or liquids the standard is usually water, and for gases the stand-
ard is air or hydrogen.
Jurandir Primo 8 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
NOTES:
1. Multiply barometer in inches by 0.491 to obtain psi. *Vacuum gauge readings inches corre-
spond to suction lift in feet only when pump is stopped. Pipe friction increases the vacuum gauge
readings when pump is running. For quiet operation, vacuum gauge should never register more
than 20 inches when pump is running.
2. When pumping volatile liquids as gasoline and naphtha, special consideration to the amount
of suction lift and the size of the suction pipe. The suction lift, the pipe line friction should
never exceed 12 feet.
3. For liquids such as lube oil, molasses, etc., a suction lift up to 24 feet, sea level, is usually
satisfactory.
Jurandir Primo 9 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
Example: Install a small pipe or tubing (about 1/8 inches or 1/4 in) in a well. The exact
length must be carefully measured. The end of the air pipe should extend to the bottom
of the pump suction. Install a reliable pressure gauge, so that the exact air pressure in
pounds may be shown, when the hand pump is operated.
Solution: Attach the hand tire-pump and fill pipe until further pumping can not increase
the reading on the gauge. Multiply the reading in pounds by 2.31, and subtract the re-
sult from the length of air pipe. The difference will be the distance from the center of the
pressure gauge face to the surface of the water. Any horizontal distance of the pipeline
from the well opening has no effect on the result.
Example: An air pipe is 100 feet long from center of gage face to bottom end of pipe.
The highest pressure reading is 18 pounds, then, 18 x 2.31 = 41.58 feet of lift.
41.58 100 = 58.42 - showing that the water level is 58.42 feet below center
of pressure gage.
Doubling the diameter of pipe or cylinder increases its capacity four times.
Friction of liquids in pipes increases with the square of the velocity.
Atmospheric pressure at sea level is 14.7 pounds per square inch. This
pressure with perfect vacuum will maintain a line of mercury 29.9 inches or a
column of water 33.9 feet high.
In practice, however, pumps should not have a total dynamic suction lift greater
than 26 feet.
Jurandir Primo 10 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
First determine if you are going to have a cavitation problem, you will need access to
several additional parts of information:
The pump curve is going to show you the Net Positive Suction Head (NPSH)
required at a given capacity. Keep in mind that this NPSH required tables are for
cold and fresh water.
A chart or some type of publication will give you the vapor pressure of the fluid
you are pumping.
You need to know the specific gravity of your fluid. The number is temperature
sensitive. You can get this number from a Temperature Pressure chart.
Find the charts showing the head loss through the size of piping and charts to
calculate the loss for fittings, valves and accessories.
Find the atmospheric pressure at the time you are making your calculation. The
atmospheric pressure changes throughout the day, but the calculations have to
start somewhere.
The formulas for converting pressure to head and head back to pressure in the im-
perial system are as follows:
Pressure = head x Sg
2.31
Sg = Specific Gravity;
Pressure = pounds per square inch, psi;
Head = feet
You also need to know the formulas that show you how to convert vacuum readings to
feet of head. Here are a few of them:
It is necessary to know the conditions below, using a pump graphic as shown below:
NPSHa > NPSHr = NPSH available (calculated) > NPSH required (pump curve).
Jurandir Primo 11 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
NPSHa = +-H + Pa Pv Hf =
H = Static Suction Head (positive when liquid line is above pump centerline, nega-
tive when liquid line is below pump centerline).
Pa = Atmospheric pressure with installed pump according to altitude from sea lev-
el (see table 05) converting to head - suction pressure x 2.31/Sg
Pv = Vapor pressure according to temperature of water (see table 02) - convert-
ing to head - vapor pressure x 2.31/Sg = Total feet.
Hf = See tables indicating friction loss for water flow through ASME/ANSI B36.10
schedule 40 steel piping. Fittings friction loss = K x v/2g (g = 32.17 ft/s).
Obs.: The ANSI/ASME codes or the Hydraulic Institute Standards is the source for pres-
sure head loss K coefficients:
Fluid: Water;
Pipe: Steel Pipe - Schedule 40;
Temperature: 20.0 oC (68.0 oF);
Density: 998.3 kg/m3 (62.0 lb/ft3);
Kinematic Viscosity: 1.004. 10-6 m2/s (0.01 stokes) (1.08. 10-5 ft2/s);
Pipe Roughness Coefficient: 4.5. 10-5.
Jurandir Primo 12 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
NPSHa = +-H + Pa Pv hf =
Pa - Atmospheric pressure =
pressure x 2.31/Sg. = 14.7 x
2.31/1 = +34 feet absolute.
Hf - Looking at the friction charts: 100 gpm - flowing through 2 inch pipe
shows a loss of 17.4 feet for each 100 feet of pipe, then:
Total friction loss for piping and fittings = Hf = 1.74 + 1.77 = 3.51 feet.
Jurandir Primo 13 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
The pump curve showed an NPSHr of only 9 feet of head at 100 gpm. According to above
calculation we have NPSHa (available) = 34.7 feet. So, we have plenty to spare.
2. Using the same data above, find the NPSHa in metric numbers:
Water density 1000 kg/m = 10,330 kg/m2 = 10.33 m of water column (mwc)
1000 kg/m
Water density 1000 kg/m = 240 kg/m2 = 0.24 m of water column (mwc)
1000 kg/m
According to metric tables: for 22.7 m/h using piping diameter 2 inches and length of
100.0 m, the total friction loss is considered = ~25%, then:
Then:
a. NPSHa = +-H + Pa Pv hf =:
b. NPSHa = +3.0 + 10.33 0.24 1.25 = 11.84 m (NPSHa) > 2.75 m (NPSHr).
c. Solution: The pump curve showed an NPSHr of only 2.75 m of head at 22.7 m/h.
According to above calculation we have NPSHa (available) = 11.84 m. So, we have
plenty to spare.
Jurandir Primo 14 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
Important Conversions:
Convert to
Convert from
m3/s m3/min m3/h liter/sec liter/min liter/h
Fluid: Water Static Suction Lift = 15 ft; Static Discharge Head = 7.5 ft.
NPSHr according to performance pump curves = 5.0 ft
Atmospheric pressure - corrected = 6 ft
Safety factor for atmospheric pressure = 2.0 ft
Jurandir Primo 15 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org
c. Solution: NPSHa (9.05) > NPSHr (5.00) - See the sketch below:
-18,85
Jurandir Primo 16 of 17
www.PDHcenter.com PDH Course M346 www.PDHonline.org