7S60ME-C8.5 - 105.0 - RPM - 14400 - KW - HL Full Report
7S60ME-C8.5 - 105.0 - RPM - 14400 - KW - HL Full Report
7S60ME-C8.5 - 105.0 - RPM - 14400 - KW - HL Full Report
Light running margin (LRM) is 7%. Recommended value is 4-10%. The LRM should be evaluated for each ship project depending on: In-
service increase of vessel resistance, ship manoeuvring requirements and requirements related to a possible barred speed range (short
passing time).
Page 1 of 10
Report created by mario1
7S60ME-C8.5 with high load tuning
SMCR: 14,400 kW at 105.0 r/min, 1 x MHI MET66-MA.
Turbocharger specifications
Turbocharger type Conventional T/C
Turbocharger make/model MHI MET66-MA
Number of turbochargers 1
Turbocharger lubrication Common (system oil)
Tier II
Exhaust gas SMCR NCR
temperature oC oC
Tier II
Turbocharger air SMCR NCR
consumption kg/s kg/s
ISO 31.7 31.7
Tropical 29.3 29.3
Specified 29.9 29.9
ISO, tropical and specified conditions are listed in the References and tolerances section.
Local time CPH (GMT + 01:00): Feb 8th 2017 04:11:43 v. 1.3.6.1 s: id=e0749101-24d0-4257-abe4-2582d4080073
The above information is for guidance only and can only be used in the initial stages of projects. The final design values are
always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo Page 2 of 10
Report created by mario1
7S60ME-C8.5 with high load tuning
SMCR: 14,400 kW at 105.0 r/min, 1 x MHI MET66-MA.
Tier II
Flow Central water flow Heat dissipation
Cooler m3/h m3/h kW
Scavenge air - 190 5,090
Lubrication oil 340 150 1,260
Jacket water 120 150 1,920
Central water*) 410 340 8,270
Fuel oil circulation (MGO/MDO) - - 35
*) The Flow column contains the sea water flow through the central cooler.
All flows are stated as minimum required flows.
The pump heads stated are for guidance only, and depend on the actual pressure drop across coolers, filters, etc. in the systems. The
capacities do not account for any components other than the engine itself.
Pertaining cooling water flow diagram, temperatures, viscosities and pressures for pumps and coolers, see Engine Project Guide.
Local time CPH (GMT + 01:00): Feb 8th 2017 04:11:43 v. 1.3.6.1 s: id=e0749101-24d0-4257-abe4-2582d4080073
The above information is for guidance only and can only be used in the initial stages of projects. The final design values are
always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo Page 3 of 10
Report created by mario1
7S60ME-C8.5 with high load tuning
SMCR: 14,400 kW at 105.0 r/min, 1 x MHI MET66-MA.
Miscellaneous
Jacket water expansion tank*) 10 %
Motor rating, auxiliary blowers 2 x 65 kW
*) Jacket water expansion tank volume given in percent of the total jacket water volume.
Local time CPH (GMT + 01:00): Feb 8th 2017 04:11:43 v. 1.3.6.1 s: id=e0749101-24d0-4257-abe4-2582d4080073
The above information is for guidance only and can only be used in the initial stages of projects. The final design values are
always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo Page 4 of 10
Report created by mario1
7S60ME-C8.5 with high load tuning
SMCR: 14,400 kW at 105.0 r/min, 1 x MHI MET66-MA.
Overhaul heights
H1: Normal lifting procedure 10,800 mm
H2: Reduced height lifting procedure 10,000 mm
H3: Tilted lifting with double jib crane 9,775 mm
Crane capacities
Normal lifting procedure 4.0 t
With electrical double jib crane 2 x 2.0 t
Masses
Mass of main engine, dry 393 t
Mass of water and oil in engine 3.0 t
The real engine length at crankshaft centreline level may be larger than the minimum length of the engine, as it depends on the vibration
conditions of the main engine and shaft system, i.e. on whether a vibration damper and/or moment compensator needs to be installed.
The mass can vary up to 10% depending on the design and options chosen.
Local time CPH (GMT + 01:00): Feb 8th 2017 04:11:43 v. 1.3.6.1 s: id=e0749101-24d0-4257-abe4-2582d4080073
The above information is for guidance only and can only be used in the initial stages of projects. The final design values are
always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo Page 5 of 10
Report created by mario1
7S60ME-C8.5 with high load tuning
SMCR: 14,400 kW at 105.0 r/min, 1 x MHI MET66-MA.
Fuel consumption and exhaust gas data (fuel oil, Tier II)
Local time CPH (GMT + 01:00): Feb 8th 2017 04:11:43 v. 1.3.6.1 s: id=e0749101-24d0-4257-abe4-2582d4080073
The above information is for guidance only and can only be used in the initial stages of projects. The final design values are
always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo Page 6 of 10
Report created by mario1
7S60ME-C8.5 with high load tuning
SMCR: 14,400 kW at 105.0 r/min, 1 x MHI MET66-MA.
Fuel consumption and exhaust gas data (fuel oil, Tier II)
Comments / details:
SFOC: Specific Fuel Oil Consumption (LCV: 42,700 kJ/kg) *) Mixed exhaust gas temperature after turbocharger.
Loads below 50% are associated with larger tolerances. **) Guiding steam production capacity at 7.0 bara. Contact boiler
maker for actual steam production.
Local time CPH (GMT + 01:00): Feb 8th 2017 04:11:43 v. 1.3.6.1 s: id=e0749101-24d0-4257-abe4-2582d4080073
The above information is for guidance only and can only be used in the initial stages of projects. The final design values are
always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo Page 7 of 10
Report created by mario1
7S60ME-C8.5 with high load tuning
SMCR: 14,400 kW at 105.0 r/min, 1 x MHI MET66-MA.
1 2 3 4 5 6 7 8
ISO condition Ambient air: 25.0 C Scavenge air coolant: 25.0 C
100 31.7 3.78 37 5,110 1,730 1,130 0.0
95 30.6 3.61 36 4,730 1,660 1,120 0.0
90 29.5 3.44 35 4,350 1,600 1,100 0.0
85 28.4 3.27 34 3,980 1,530 1,080 0.0
80 27.2 3.14 33 3,670 1,470 1,060 0.0
75 25.9 3.02 32 3,360 1,410 1,040 0.0
70 24.6 2.83 31 2,980 1,340 1,010 0.0
65 23.2 2.64 30 2,610 1,280 980 0.0
60 21.8 2.45 30 2,240 1,210 950 0.0
55 20.2 2.26 29 1,880 1,150 920 0.0
50 18.6 2.07 28 1,540 1,090 880 0.0
45 17.0 1.91 27 1,240 1,020 840 0.0
40 15.2 1.76 26 970 960 800 0.0
35 13.4 1.62 33 730 890 750 0.0
30 13.9 1.49 32 620 830 700 0.0
25 11.7 1.37 32 420 770 640 0.0
Local time CPH (GMT + 01:00): Feb 8th 2017 04:11:43 v. 1.3.6.1 s: id=e0749101-24d0-4257-abe4-2582d4080073
The above information is for guidance only and can only be used in the initial stages of projects. The final design values are
always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo Page 8 of 10
Report created by mario1
7S60ME-C8.5 with high load tuning
SMCR: 14,400 kW at 105.0 r/min, 1 x MHI MET66-MA.
B) Airborne sound pressure levels - with standard noise reduction (NR) countermeasures (2x10-5 Pa).
Expected mean sound pressure octave spectrum levels, i.e. the average spatial noise values at a distance of 1 metre from the engine.
Prescribed measuring surface area is 431.6 m.
C) Air-borne sound pressure levels - with additional noise reduction (NR) countermeasures (2x10-5 Pa).
Expected mean sound pressure octave spectrum levels, i.e. the average spatial noise values at a distance of 1 metre from the engine.
Prescribed measuring surface area is 431.6 m.
Other additional noise reduction countermeasures are also available. The noise figures given are in accordance with the CIMAC
recommendations for measurements of the overall noise for reciprocating engines. The average levels will, depending on the actual
engine room configuration, be 1-5 dB higher when the engine is installed in the engine room.
Local time CPH (GMT + 01:00): Feb 8th 2017 04:11:43 v. 1.3.6.1 s: id=e0749101-24d0-4257-abe4-2582d4080073
The above information is for guidance only and can only be used in the initial stages of projects. The final design values are
always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo Page 9 of 10
Report created by mario1
7S60ME-C8.5 with high load tuning
SMCR: 14,400 kW at 105.0 r/min, 1 x MHI MET66-MA.
Reference data
Ambient Scavenge air coolant Ambient air Relative air Barometric Exhaust back
condition temperature*) temperature humidity pressure pressure
oC oC % mbar mmWC
ISO**) 25 25 30 1,000 300
Tropical 36 45 60 1,000 300
Specified 10 30 60 1,000 300
Further reading: www.mandieselturbo.com/Papers/Influence_Of_Ambient_Temperature_Conditions p. 7-11
*) With a central cooling system, the sea water will be 4 oC lower than these temperatures.
**) Refers to ISO 3046-1 2002(E) and ISO 15550:2002(E).
Tolerances
Specific fuel consumption tolerance (SMCR) +/- 5 %
Exhaust gas amount tolerance +/- 5 %
Exhaust gas temperature tolerance +/- 15 oC
e0749101-24d0-4257-abe4-2582d4080073
This ID must be used by an MDT licensee when creating a DSO.
Local time CPH (GMT + 01:00): Feb 8th 2017 04:11:43 v. 1.3.6.1 s: id=e0749101-24d0-4257-abe4-2582d4080073
The above information is for guidance only and can only be used in the initial stages of projects. The final design values are
always to be supplied by the licensed engine builder, the engine supplier or confirmed by MAN Diesel & Turbo Page 10 of 10