4R100 Solenoid Operation Chart
4R100 Solenoid Operation Chart
4R100 Solenoid Operation Chart
Failed OFF due to PCM/vehicle wiring concerns; solenoid electrically or hydraulically stuck off.
Failed ON due to PCM/vehicle wiring concerns; solenoid electrically or hydraulically stuck on.
SSA Always On
Gear Lever Position
PCM Gear Commanded (D) 2 1
Actual Gear Obtained
1 1 2 1
2 2 2 1
3 2 2 1
4 1 2 1
SSB Always On *
Gear Lever Position
PCM Gear Commanded (D) 2 1
Actual Gear Obtained
1 2 2 1
2 2 2 1
3 3 2 2
4 3 2 2
*
PTO will always be on.