Open navigation menu
Close suggestions
Search
Search
en
Change Language
Upload
Sign in
Sign in
Download free for days
0 ratings
0% found this document useful (0 votes)
141 views
6 pages
Reformer PDF
Uploaded by
ATUL SONAWANE
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Download
Save
Save Reformer.pdf For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
0 ratings
0% found this document useful (0 votes)
141 views
6 pages
Reformer PDF
Uploaded by
ATUL SONAWANE
AI-enhanced title
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here
.
Available Formats
Download as PDF or read online on Scribd
Carousel Previous
Carousel Next
Download
Save
Save Reformer.pdf For Later
0%
0% found this document useful, undefined
0%
, undefined
Embed
Share
Print
Report
Download now
Download
You are on page 1
/ 6
Search
Fullscreen
4 REFORMER BY MAZDA AND C-R IMPROVE PLANT PERFORMANCE AND PRODUCT QUALITY new advanced design to help you improve the efficiency and effectiveness of your business by offering you, ; unrivalled knowledge of improving steam quality at mini- mum capital outlay and running costs. Patent PendingRecommended installations of Reformer valves in an existing process plant On any steam distribution system Reformer can help you achive maximum efficiency and save energy all along the linelean steam and compressed airmean maximum efficiency and minimum maintenance. Dust, scale, rust, jointing mate- rial, weld metal and other for- eign particles will clog valves, put drain traps out of action, block orifices and ruin processes. eparators can promote higher produc- tion for lower Juelcost because steam containes more heat than hot water at the same pressure. Steam as dry as possible at the point of use 1s important. Steam Separators improve the rate of heat transfer.Some typical reformer applications for fuel savings and increased production Increased productivity of steam using equipment Reformer Valve in a reducing system will improve steam equipment productivity, pressure reducing valve service life is extended, © since the effective removal of condensate and scale protects the main valve from erosion. Yankee dryer increased production with savings in fuel Installed at a paper factory in Gujarat on dryersand ‘olinders paper making machine production was increased by 1 foot in 20 feet and fuel consumption reduced. Steam jet ejectors Installation of Reformer unit has improved the ‘vacuum performance at a leading food processor. Reforming valves greatly improve the efficiency of Steam jet eectors. Wet steam or poor quality of steam is detrimental to steam jet vacuum systems. In many cases by installing reforming valve the required ‘vacuum is achieved and enbancing the performance ofthe plant under vacuum with most advantageous operating results, Better Rubber with fuel savings. By installing a reformer valve production was increased by maintaining a uniform temperature and avoided spots in the rubber and a better product was produced with less spoilage. Production was also increased and a fuel savings of 10 % was realised.Reformer for optimum heat transfer ‘The illustration shovws diagrammatically the flow of heat ‘from a steam space to a product being heated. The final temperature must be 98.8°C. The steam temperature must be sufficiently above this for heat to flow through the water film and metal. Ifthe resistance of water film can be decreased the steam pressure can be reduced. In the diagram, by reducing the water film on the steam side by one half, the steam pressure necessary can be cut from 1 Kg/em’g to 0.7 Kg/em*g. Installation of a reformer at the steam supply lines to the process plants will not only enable process plant to give its best output but also allow it to operate most efficiently at the lowest possible pressure. Remember wet steam supply deposits its excess water, increasing the resistant water film at the heat transfer surface, thus impending heat tiansfer. This water film is berween 60 and 70 times more resistant to heat transfer than the iron or steel wall of the heating suface. Operation and separation efficiency Reformer filters and separates water particles from flowing stream by employing the two best methods of separation. A confounded series of vanes and fins change the stearn, air or gas flow into a high speed cyclone flow, separating even mist - like condensate with 98 % efficiency. The fluid velocity is firse maintained but the flow is given a twist so that the heavier water droplets ave flung out of suspension by centrifugal {force against the sides of the vessel. The flow area is then increased +0 that the fluid velocity drops to prevent pickup of separated water. Separation efficiency test conducted in our in-house steam test facility with Croll Reynolds Company, Inc. USA Steam Calorimeter.NOTES : 1. All dimensions are in mm and are to be used for estimation only. 2. Centfied drawings will be supplied on request. 3. I5mm and 20mm sizes have screwed connections. Standard screwed connections are BSP (parallel) chreads. Other threads can be supplied, if required i.e. NPT, DIN et. 4. Sizes above 100mm can be made available on request. 5. The flanged connections are to ANSI 150 # and 300 # raised face. Higher ratings will ‘be applied depending on the duty conditions. LIMITED Mazda House, Panchwati 2nd Lane, Ambawadi, Ahmedabad 380 006. INDIA. Phone : + 91 (0) 79 40007000 (30 Lines) © Fax : + 91 (0) 79 26565605 © E-Mail : vacuum@mazdali Please visit us at : www.mazdalimited.com sd.com
You might also like
Steam Reformers 1 1
PDF
No ratings yet
Steam Reformers 1 1
51 pages
PROJECT REPORT - RO Water Plant
PDF
No ratings yet
PROJECT REPORT - RO Water Plant
24 pages
Centrifugal Pumps Design and Application
PDF
100% (2)
Centrifugal Pumps Design and Application
592 pages
Separator Design
PDF
100% (1)
Separator Design
6 pages
Rigorously Size Relief Valves For Critical Fluids
PDF
100% (3)
Rigorously Size Relief Valves For Critical Fluids
10 pages
CC Pump Manual Full Original
PDF
No ratings yet
CC Pump Manual Full Original
109 pages
Alstom Process Gas Cooler
PDF
100% (1)
Alstom Process Gas Cooler
12 pages
Combustion Technology
PDF
No ratings yet
Combustion Technology
51 pages
Problem, Failure and Safety Analysis of Ammonia Plant-A Review
PDF
67% (3)
Problem, Failure and Safety Analysis of Ammonia Plant-A Review
16 pages
Plenty Duplex Filter: 1" - 4"size.: Design Pressure
PDF
100% (1)
Plenty Duplex Filter: 1" - 4"size.: Design Pressure
2 pages
09 Cooling System
PDF
No ratings yet
09 Cooling System
36 pages
Steam Reformer Design and Construction
PDF
89% (9)
Steam Reformer Design and Construction
9 pages
CC Pump Manual-Full (Original)
PDF
100% (1)
CC Pump Manual-Full (Original)
109 pages
Lubrication Systems For Turbomachinery by Fredrick B. Wilcox
PDF
No ratings yet
Lubrication Systems For Turbomachinery by Fredrick B. Wilcox
4 pages
Matreail Balance
PDF
No ratings yet
Matreail Balance
1 page
Spherical Tanks PDF
PDF
100% (1)
Spherical Tanks PDF
2 pages
D4011BRO
PDF
No ratings yet
D4011BRO
2 pages
LSMtron Operating Maintenance
PDF
No ratings yet
LSMtron Operating Maintenance
56 pages
MD - DTDP Diagrams Sample
PDF
No ratings yet
MD - DTDP Diagrams Sample
16 pages
Sulzer Revamp Compressor
PDF
100% (1)
Sulzer Revamp Compressor
4 pages
Refrigerant Piping
PDF
No ratings yet
Refrigerant Piping
23 pages
An04448641748502 000701
PDF
No ratings yet
An04448641748502 000701
6 pages
Refrigerant Piping
PDF
No ratings yet
Refrigerant Piping
23 pages
Reformer Sagar Presentation
PDF
No ratings yet
Reformer Sagar Presentation
43 pages
Refrigerant Piping
PDF
No ratings yet
Refrigerant Piping
8 pages
Refigeration KBu Sept 20
PDF
No ratings yet
Refigeration KBu Sept 20
85 pages
Thermosag Brochure
PDF
No ratings yet
Thermosag Brochure
47 pages
Eurocon Building Industries Fze Submittal
PDF
No ratings yet
Eurocon Building Industries Fze Submittal
52 pages
L132-L250 Service TrainingV2
PDF
No ratings yet
L132-L250 Service TrainingV2
35 pages
CM-5-4 Grundfoss
PDF
No ratings yet
CM-5-4 Grundfoss
5 pages
All 3
PDF
No ratings yet
All 3
32 pages
Brochure PDR English 07
PDF
100% (1)
Brochure PDR English 07
16 pages
Brine Properties
PDF
100% (3)
Brine Properties
26 pages
Specification of Filter Machine, Oil Tank and Vaccum Pump
PDF
No ratings yet
Specification of Filter Machine, Oil Tank and Vaccum Pump
1 page
Edible Oil
PDF
No ratings yet
Edible Oil
12 pages
HS4A Bulletin
PDF
No ratings yet
HS4A Bulletin
12 pages
DSH VARIflow PDF
PDF
No ratings yet
DSH VARIflow PDF
14 pages
Special-Purpose Centrifugal Fans For Refinery Services: AUGUST 1984 Page 1 of 9
PDF
No ratings yet
Special-Purpose Centrifugal Fans For Refinery Services: AUGUST 1984 Page 1 of 9
25 pages
Venturi Nozzle Systems Questions and Answers
PDF
No ratings yet
Venturi Nozzle Systems Questions and Answers
1 page
Over Dimensional - Over Weight Cargo Movement-Online Application Processing-Morth
PDF
No ratings yet
Over Dimensional - Over Weight Cargo Movement-Online Application Processing-Morth
6 pages
Desuperheaters Power Plants
PDF
100% (1)
Desuperheaters Power Plants
6 pages
TVR II All Inverter - Water-Cooled - 380-415V - 50-60Hz - 3ph - Technical Service Manual
PDF
No ratings yet
TVR II All Inverter - Water-Cooled - 380-415V - 50-60Hz - 3ph - Technical Service Manual
21 pages
Hot Gas Defrost For Ammonia Evaporators: Bulletin 90-11c
PDF
No ratings yet
Hot Gas Defrost For Ammonia Evaporators: Bulletin 90-11c
24 pages
Chap 3 5
PDF
No ratings yet
Chap 3 5
4 pages
Discussion
PDF
No ratings yet
Discussion
8 pages
O&M Manuals - Process Vacuum Pumps
PDF
No ratings yet
O&M Manuals - Process Vacuum Pumps
28 pages
Midi Pressmatic II
PDF
No ratings yet
Midi Pressmatic II
6 pages
Centrifugal Pump With Volute Casing: Original Operating Manual NIT Series
PDF
No ratings yet
Centrifugal Pump With Volute Casing: Original Operating Manual NIT Series
40 pages
Frigorifica Informaçaes Gerais
PDF
No ratings yet
Frigorifica Informaçaes Gerais
28 pages
Refrigerator
PDF
No ratings yet
Refrigerator
9 pages
I and O-1012 - 1014 - 1015 - and 1017 Pumps 1-1
PDF
No ratings yet
I and O-1012 - 1014 - 1015 - and 1017 Pumps 1-1
12 pages
Hydraulics
PDF
No ratings yet
Hydraulics
8 pages
Resistance Equivalent Length
PDF
No ratings yet
Resistance Equivalent Length
3 pages
Bulletin 90 11c
PDF
No ratings yet
Bulletin 90 11c
24 pages
Coolantpump PDF
PDF
No ratings yet
Coolantpump PDF
32 pages
Difference Between 304 316 and 220517
PDF
No ratings yet
Difference Between 304 316 and 220517
2 pages
CM-10 Grundfoss
PDF
No ratings yet
CM-10 Grundfoss
6 pages
Process Data: Shell Side Tube Side
PDF
No ratings yet
Process Data: Shell Side Tube Side
1 page
Material Stream: 1. Column In: Conditions
PDF
No ratings yet
Material Stream: 1. Column In: Conditions
15 pages
Chiller Tech2 - EIL Delhi
PDF
No ratings yet
Chiller Tech2 - EIL Delhi
4 pages
Belt Driven Vacuum Pump
PDF
No ratings yet
Belt Driven Vacuum Pump
3 pages
Technical Brochure MEC 9-11-13500rev1
PDF
No ratings yet
Technical Brochure MEC 9-11-13500rev1
7 pages
Shell Side Tube Side Process Data
PDF
No ratings yet
Shell Side Tube Side Process Data
1 page
1
PDF
No ratings yet
1
2 pages
Standard S2000 HH Specifications Stancor Pumps
PDF
No ratings yet
Standard S2000 HH Specifications Stancor Pumps
2 pages
Hydraulic Coolers
PDF
No ratings yet
Hydraulic Coolers
12 pages
Desuperheater PDF
PDF
No ratings yet
Desuperheater PDF
7 pages
Liq Ring Water Pump
PDF
No ratings yet
Liq Ring Water Pump
1 page
300L Liuid Soap Making Machine
PDF
No ratings yet
300L Liuid Soap Making Machine
3 pages