The document provides specifications for a VTC511 series thermostatic radiator valve. It lists the maximum system and differential pressures the valve can handle. It also includes application information showing suitable thermostats for different valve locations and their opening temperatures. Diagrams illustrate typical piping schematics and valve selections.

Uploaded by

Viorell
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
261 views4 pages

VTC500 Instruc Final PDF

The document provides specifications for a VTC511 series thermostatic radiator valve. It lists the maximum system and differential pressures the valve can handle. It also includes application information showing suitable thermostats for different valve locations and their opening temperatures. Diagrams illustrate typical piping schematics and valve selections.

Uploaded by

Viorell
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Series VTC511

PED 97/23/EC

+230 +230

145 /10 xxx/6


5 5

+32 +32
+32

SERIES VTC500
0 15 0 15

PSI/bar Mpa/bar

F Psi/bar F Psi/bar
Max system pressure =
145psi (10 bar)
Max differential pressure between ports and , and =
14.5 psi (1bar) across the valve to ensure tight close off.

Mtrl.nr. 9814 03 60 Ritn.nr. 9178 utgp.A Rev. 0908 Max differential pressure between ports and =
4.35 psi (0.35 bar)

Application Thermostat ordered separately Thermostat Element Installation

Valve Suitable Code No. Opening Temperature


Location Thermostats
Boiler 158F (70C) 193B1702 122F (50C)
of Storage Protection

Outlet Line 176F (80C)


193B1703 131F (55C)
Boiler

Boiler 122F (50C)


Return Line 131F (55C) 193B1704 140F (60C)
140F (60C)
193B1709 149F (65C)
158F (70C)
Charging

Tank Feed Line


176F (80C) 193B1705 158F (70C)
Tank

Tank
All 193B1706 167F (75C)
Return Line VTC 511
75C/176F

VTC 511
75C/176F

Thermostat VTC 511


75C/176F

8Nm
6.0 lbf.ft

8Nm
6.0 lbf.ft 8Nm
6.0 lbf.ft

VTC 511
75C/176F
Boiler Outlet Mounted Boiler Return Mounted

Typical for 122F (50C)/131F (55C) /140F (60C) Thermostats


Typical for 158F(70C)/176F (80C) Thermostats

Gravity Conversion System or Hydronic Heating System Gravity Conversion-, Multi-Zone-, or Hydronic Heating - System Solar Heating

Max 230F (110 C)

Piping Schematics are General Representations


Proper Valve Selection

1
bar PSI

0.80
11

0.70 10

9
0.60
8

10
0.50
7

Cv
1-1/4
0.40 6

5
0.30
16
4 Cv
3
0.20 3 2

2
0.10
1

0
0 5 10 15 20 25 30 35 GPM

100000

t t
250 000 200 000 t= 250 000 15C/
15C/ 18
Btu F Btu 27F
27F (10
C)
1 t
=2
7
300 000 t F
=3 (1
5
C)
6
F
? ?
t
(2
0

=4
C)
400 000

5
F
? bar Cv ? 0.22 bar Cv 10

(2
5
? GPM 18 GPM

C)
500 000

Btu/h

You might also like