(V8106) DataSheet EN 160316 V1.1 PDF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 27
At a glance
Powered by AI
The document provides details about the V8106 OLT chassis including its components, slot allocation, interface units and ordering information.

The V8106 chassis has 17 slots that can accommodate switching fabric units, service interface units, network interface units, an offload processor unit, clock interface unit and power supply units.

The V8106 uses PON (Passive Optical Network) technology to provide fiber access to subscribers.

DATA SHEET

V8106
Data Sheet
V8106

Issue History
Version Date of Issue Reason for Update
V1.0 11/2015 Initial release
V1.1 03/2016 LED description modified
SFP, SFP+ module option added.
Ordering Information added.

V1.1 Page 2 of 27
Data Sheet
V8106

1 Product Overview
The V8106 is a 6RU height chassis PON Optical Line Termination (OLT) supporting 96 GPON
ports as well as a Layer 3 switch of supporting 8 1/10GbE ports Active Ethernet service. It
terminates the traffic coming from the subscriber lines and consolidates it on one or more
Gigabit Ethernet interfaces towards the metropolitan area.

Figure 1 Front View of the V8106

The V8106 chassis has 17 slots. The 2 slots are reserved for SFU cards for control/switching,
6 slots for service interface card, 2 slots for uplink interface cards, 1 slot for OLP (Offload
Processor) module, 1 slot for clock interface module, as well as 2 slots are reserved for dual
power modules (PSUs), 2 slots for fan modules, 1 slot for dust filter, The V8106 is a carrier-
class equipment, fully redundant, in a modular and high capacity architecture with 6 interface
unit slots. These 6 slots can be used for subscriber interface units and two uplink interface
units for full redundancy architecture.

It is a high-density chassis system that supports up to 12,288 residential and business sub-
scribers with 96 GPON ports (1:128 split ratio). It also provides simultaneous services of
GPON and Gigabit Ethernet. V8106 features flexible and high capacity PON access and
10GbE uplinks, scalability and line rate performance with a 640Gbps non-blocked switch fab-
ric.

The V8106 guarantees equipment-level reliability with full redundancy design concept of
SFU/Power/GPON ports. This is a substantial factor for aggregation switches to perform con-
tinuous traffic forwarding to core network without failure. The PON technology adds new fea-
tures and functionality targeted at improving performance and interoperability, and adds sup-
port for new applications, services, and deployment scenarios.

The PON technology adds new features and functionality targeted at improving performance
and interoperability, and adds support for new applications, services, and deployment sce-
narios. Among these changes are improvements in data rate and reach performance, diag-
nostics, and stand-by mode, to name a few.

The V8106 introduces a point-to-multipoint concept with the PON technology, which enables
a cost-effective FTTx service. The reason why PON is considered as a cost-effective solution
is its usage of a passive splitter rather than an active switching system.

The benefits of the passive splitter are as follows:

V1.1 Page 3 of 27
Data Sheet
V8106

No power supply is needed.


No maintenance is needed.
The splitter does not need any fiber optic transceiver. The number of fiber optic
transceivers in the network is minimized.

Service
Interface Unit (SIU)
6 slots

Switch Fabric Unit (SFU)


2 slots

FAN Power Network Clock OLP Power Network


Unit Supply Interface Interface Interface Supply Interface
Unit Unit Unit Unit Unit Unit

Figure 2 Front Interfaces of the V8106

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5
Dust Filter

Slot 6
FAN FAN
Slot A

Slot B

NIU Slot 1 OLP NIU Slot 2

Slot A Slot B
PSU Slot A CIF PSU Slot B

Figure 3 V8106 Slot Allocation

V1.1 Page 4 of 27
Data Sheet
V8106

Items # of Slot Unit name Connector type Description

Basic Shelf - - 17-slot chassis with front access


Switching card 2 slots SFU - Switch fabric unit
(SFU) - Switching capacity: 640Gbps per unit
- MGMT/ Console
Interface Unit (IU) 6 slots SIU_GPON16 SFP 16 GPON ports per service module
2 slots NIU_10GE4 SFP+ 4 optical 10GE ports per uplink module
Power unit 2 slots PSU_DC - DC Power Supply Unit
(PSU) - DC48/60V, maximum 40A
*Available in the
Clock unit 1 slot CIF - Clock Interface unit
future

*Available in the
OLP unit 1 slot OLP Offload Processor
future

Fan unit 2 slots FAN - Fan unit


Dust Filter 1 slot Dust Filter - To prevent an inflow of dust into the shelf

Table 1 System Structure of the V8106

1.1 Plug-in Units


1.1.1 Switch Fabric Unit (SFU)
The switch fabric unit (SFU) is a central switching fabric unit, which is equipped in the front
mounting slot of the shelf. The SFU holds a switching fabric, system internal data interfaces
to the interface units within the shelf, and also management interfaces such as con-
sole/MGMT and LEDs indicating the status of system and SFU.

Figure 4 shows the front view of the SFU

Console Access Alarm LEDs


Operating LEDs MGMT Interface
PSU status LEDs Active LED
(RS232) (10/100/1000Base-T)

SD Memory status LED SD Memory Slot Alarm Interface

Figure 4 Front View of SFU

Item Function Connector Type

Operating LEDs Indicator for system operating status including power, fault de- -
tection and booting state.
CONSOLE CLI access to configure the functions for system operation RJ45 (RS232)
MGMT Out of band TMN-OS Interface RJ45
SD Memory Sta- Indicator for SD memory status -
tus LED

V1.1 Page 5 of 27
Data Sheet
V8106

Item Function Connector Type

SD Memory Slot Slot for SD memory card Micro SD


PSU LEDs Indicator for power status (PSU A/B) -
Alarm LEDs Indicator for alarm status (critical/major/minor) -
Active LED Indicator for SFU status whether active or standby. -
Alarm Alarm interface RJ45

Table 2 Front Access Interfaces of SFU

Operating Status LEDs on SFU

PWR RUN ERR Meaning of LED state


(Green) (Green) (Red)
On On Off SFU is operational and providing the service, no fault present.
On SFU is operational and providing the service, but there is a partial failure.
It detects the abnormal operation of IBC or IPC.
Blinking On Power-up diagnostics or loading in partial failure mode.
Off Loading after self-diagnostics has been completed without an error
Off Off Off SFU is not supplied with power

Table 3 Operating Status LEDs on SFU

Console Interface LEDs

Label Color Status Description

TX Amber Blinking A transmit activity is present on the console.


Off No transmit activity is present on the console.
RX Green Blinking A receive activity is present on the console.
Off No receive activity is present on the console.

Table 4 Console Status LEDs on SFU

MGMT Interface LEDs

Label Color Status Description

LNK Green On Link Up


Off Link Down
ACT Amber Blinking A sending or receiving activity is present on the MGMT Interface.

Off No sending or receiving activity is present on the MGMT Interface.

Table 5 MGMT Status LEDs on SFU

V1.1 Page 6 of 27
Data Sheet
V8106

Micro SD Status LED

Label Color Status Description

SD Green On A transmit or receive activity is present on the SD memory Interface.


Memory Off No transmit or receive activity is present on the SD memory Interface.
Status

Table 6 Micro SD Status LED

PSU Status LED

Label Color Status Description

PSU Green On The V8106 is supplied with PSU A or PSU B.


A/B Off The V8106 is not supplied with PSU A or PSU B.
Amber On PSU is not supplied with PSU A or PSU B, but PSU is installed in the slot
A or PSU B.
Off PSU A or B is not installed in the PSU slot A or B.

Table 7 PSU Status LED

Alarm Status LEDs on SFU

Label Color Status Description

CRT Red On The system detects critical error; (User configuration).


- Overheating
Off The system has no critical error.
MAJ Red On The system detects major error; (User configuration).
Off The system has no major error.
- Over temperature
MIN Amber On The system detects minor error; (User configuration).
Off The system has no minor error.

Table 8 Alarm Status LEDs on SFU

SFU Status LEDs on SFU

Label Color Status Description

Active Green On The SFU is in an active state.


Off The SFU is in a standby state.

Table 9 SFU Status LEDs on SFU

V1.1 Page 7 of 27
Data Sheet
V8106

1.1.2 Interface Units (IUs)


The Interface Unit (IU) is used to concentrate traffic originated from access infrastructures
through its Gigabit Ethernet ports and carries traffic delivery to the uplink core network.

Each IU can be equipped in up to 8 slots of V8106 basic shelf.

SIU_GPON16

Operating LEDs 16 x GPON interface

Link status LED


Figure 5 Front View of SIU_GPON16

Item Function Connector Type

Operating LEDs Indicator for system operating status including power, fault de- -
tection and booting state.
Connections 16 x GPON ports SFP
L/A LEDs Indicator for ports link status and traffic activity. -

Table 10 Front Access Interfaces of SIU_GPON16

Power Status LEDs on SIU_GPON16

Label Color Status Description

PWR Green On The SIU is supplied with power source.


Off The SIU is not supplied with power source.

Table 11 Power Status LEDs on SIU_GPON16

System Operating Status LEDs on SIU_GPON16

RUN ERR Meaning of LED state


(Green) (Red)
On Off The SIU is operational and providing the service, no fault present.
On The SIU is operational and providing the service, but partial failure present.
Blinking On Power-up diagnostics or loading in partial failure mode.
Off Loading after self-diagnostics found fault-free.
Off Off locked (PWR=OFF indicates power failure)

Table 12 System Operating Status LEDs on SIU_GPON16

V1.1 Page 8 of 27
Data Sheet
V8106

Link Status LEDs on SIU_GPON16

Label Color Status Description

L/A Green On The GPON port link is up.


If type_B redundancy is supported, The IU is in an active state.
Blinking A sending or receiving activity is present on the port.
Off The port link is down.
Amber On If type_B redundancy is supported, the IU is in a standby state.
Off The port link is down.

Table 13 Link Status LEDs on SIU_GPON16

NIU_10GE4

Link status LEDs 4x 10GBase-R Interface

Operating LEDs

Figure 6 Front View of NIU_10GE4

Item Function Connector Type

Operating LEDs Indicator for system operating status including power, fault de- -
tection and booting state.
L/A LEDs Indicator for ports link status and traffic activity. -
Connections 4 x 10GBase-R ports. SFP+

Table 14 Front Access Interfaces of NIU_10GE4

Power Status LED on NIU_10GE4

Label Color Status Description

PWR Green On The NIU is supplied with power source.


Off The NIU is not supplied with power source.

Table 15 Power Status LED on NIU_10GE4

V1.1 Page 9 of 27
Data Sheet
V8106

System Operating Status LEDs on NIU_10GE4

RUN ERR Meaning of LED state


(Green) (Red)
ON OFF The NIU is operational and providing the service, no fault present
ON The NIU is operational and providing the service, but partial failure present.
Blinking ON Power-up diagnostics or loading in partial failure mode.
OFF Loading after self-diagnostics found fault-free.
OFF OFF locked (PWR=OFF indicates power failure)

Table 16 System Operating Status LEDs on NIU_10GE4

Link Status LEDs on NIU_10GE4

Label Color Status Description

L/A Green On The port link is up and the Ethernet transmit rate is 10Gbps.
Blinking A sending or receiving activity is present on the Ethernet port at
10Gbps.
Amber On The port link is up and the Ethernet transmit rate is 1Gbps.
Blinking A sending or receiving activity is present on the Ethernet port at 1Gbps.
Off The port link is down.

Table 17 Link Status LEDs on NIU_10GE4

1.1.3 Power Supply Unit (PSU)


The power supply unit (PSU) feeds the proper power voltage to the V8106. Dual PSUs could
be mounted into front side of the shelf. You can choose proper power supply unit according
to installation environment.

The power supply unit (PSU) feeds the proper power voltage to the V8106 and power con-
nector (DC type) for main power supply is located on the front panel of the PSU. For redun-
dant power feeding, the second PSU has to be used.

All plug-in units in the V8106 are supplied with a voltage of -48/60V regulated by the PSU.

Figure 7 Front View of PSU_DC

V1.1 Page 10 of 27
Data Sheet
V8106

1.1.4 FAN Unit


The V8106 is equipped with two fan units, which each contain four independent fans respec-
tively. The fan unit will be mounted inside at the left of the shelf. You can insert fan unit into a
fan slot by slowly adjusting them to fit into the slot guidance. The air inlet is at the right of the
chassis. To prevent an inflow of dust into the shelf, the dust filter is mounted at the right of
the shelf. Also, two fan units supply fan 1:1 redundancy.

The fan unit is connected to the backplane of the shelf and fed with a voltage of 12V. The
LED indicators on the fan unit show the operating status of the fan.

The fans are controlled in accordance with the measured temperature inside the system. The
temperature sensor is located in the system, and the measured values are evaluated and the
operation of the fan controlled accordingly.

Figure 8 Front View of FAN

Figure 9 Front View of FAN Unit

Operating Status LEDs on Fan Unit

Label Color Status Description

PWR Green On The FAN is operating normally.


Off The FAN is not supplied with power source.
The FAN is stopped by CLI command.
ALM Red On The plug-in unit is operational and providing the service, but partial fail-
ure present.
Off The plug-in unit is operational and providing the service, no fault pre-
sent

Table 18 Operating Status LEDs on Fan Unit

1.1.5 Dust filter


For the dust inflow filtering, V8106 basic shelf can be equipped with a 45PPI (Pixels Per Inch)
dust filter. NEBS GR-078-CORE (R8-4 [671]: air-filter 80% dust resistant)

The below shows the front view of the dust filter.

V1.1 Page 11 of 27
Data Sheet
V8106

Figure 10 Dust filter

V1.1 Page 12 of 27
Data Sheet
V8106

1.2 Component Options for V8106

Bases
Name Description Maximum
quantity

V8106 Chassis for V8106 1


- 6-slot: Subscriber Interface Unit
- 2-slot: Network Interface Unit
- 2-slot: Switching Fabric Unit
- 1-slot: Clock Interface Unit
- 1-slot: Offload processor Unit
- 2-slot: Power Supply Unit
- 2-slot: Fan Module Unit
- 1-slot: Dust Filter Unit

Table 19 Base Option

Switch Fabric Options


Name Description Maximum
quantity

V8106_SFU Switching Fabric Unit for V8106 2


- Switching capacity: 640Gbps
- Flash: 136MB (Dual OS)
- SDRAM: 2GB DDR3
- 1-port MGMT, 1-port Console
- 1-slot SD memory

Table 20 Switch Fabric Options

Interface Units
Name Description Maximum
quantity

V8106_SIU_GPON16 16-port GPON interface Unit for V8106 6


V8106_NIU_10GE4 4-port 10GBase-R interface Unit for V8106 2
- SFP+ optic module
V8106_SIU Blank Panel Blank panel for SIU 6
V8106_NIU Blank Panel Blank panel for NIU 2

Table 21 Interface Options

V1.1 Page 13 of 27
Data Sheet
V8106

Clock Interface Options


Name Description Maximum
quantity

V8106_CIF Blank Panel Blank panel for Clock interface unit 1

Table 22 Clock Interface Options

Offload Processor Options


Name Description Maximum
quantity

V8106_OLP Blank Panel Blank panel for OLP unit 1

Table 23 Offload Processor Options

Power, Fan, etc. Options


Name Description Maximum
quantity

V8106_PSU_DC DC Power Supply Unit 2


V8106_PSU_DC_Blank Blank Panel for PSU DC 2
V8106_FAN Fan unit for V8106 2
V8106_FAN_Blank Blank Panel for FAN 2
V8106_Dust Filter Dust filter for V8106 1
V8106_Cable Duct Cable duct for V8106 1

Table 24 Power and Fan Options

SFP Options
The following different optical SFP modules are available and can be inserted into the dedi-
cated slots of the SIU. Each SFP module contains one port.

SFP Module Description

SFP-GPON-OLT20 SFP GPON OLT20


- Wavelength: 1490nm/1310nm / Distance: 20 km / Mode: single-mode
- Connector: SC/PC / Data rate: 2.488Gbit/s(Down), 1.25Gbit/s(Up) /
- Core type: Single Core
- Operating Temperature: -40 C ~ 85 C
SFP-GE-SX SFP GE SX
- Wavelength: 850 nm / Distance: 550 m / Mode: multi-mode
- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C - 70 C
SFP-GE-LX5 SFP GE LX5
- Wavelength: 1310 nm / Distance: 5 km / Mode: single-mode
- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C - 70 C

V1.1 Page 14 of 27
Data Sheet
V8106

SFP Module Description

SFP-GE-LX10 SFP GE LX10


- Wavelength: 1310 nm / Distance: 10 km / Mode: single-mode
- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C - 70 C
SFP-GE-LX15 SFP GE LX10
- Wavelength: 1310 nm / Distance: 15 km / Mode: single-mode
- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C - 70 C
SFP-GE-LX20 SFP GE LX20
- Wavelength: 1310 nm / Distance: 20 km / Mode: single-mode
- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C - 70 C
SFP-GE-LX40 SFP GE LX40
- Wavelength: 1550 nm / Distance: 40 km / Mode: single-mode
- Connector: LC / Data rate: 1.25Gbit/s / Core type: Dual Core
- Operating Temperature: 0 C - 70 C

Table 25 SFP Modules for IU

Other types of SFP module can be also available upon customer request.
i

SFP+ Options
The following different optical SFP+ modules are available and can be inserted into the ded-
icated slots of the NIU. Each SFP+ module contains one port.

SFP+ Module Description

SFPP-10GE-SR SFP+ 10GE SR


- Wavelength : 850nm / Distance : 300m / Mode : Multimode
- Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
- Operating Temperature : 0C ~ 70 C
- 10GBASE-SR (10G)
SFPP-1GE10GE-SR SFP+ 1GE/10GE SR
- Wavelength : 850nm / Distance : 300m / Mode : Multimode
- Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
- Operating Temperature : 0C ~ 70 C
- 10000BASE-SX (1G), 10GBASE-SR (10G)
SFPP-10GE-LR SFP+ 10GE LR
- Wavelength : 1310nm / Distance : 10Km / Mode :Singlemode
- Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
- Operating Temperature : -5C ~ 70 C
- 10GBASE-LR (10G)
SFPP-10GE-ER SFP+ 10GE ER
- Wavelength : 1550nm / Distance : 40Km / Mode :Singlemode
- Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
- Operating Temperature : 0C ~ 70 C
- 10GBASE-ER (10G)

V1.1 Page 15 of 27
Data Sheet
V8106

SFP+ Module Description

SFPP-10GE-ZR SFP+ 10GE ZR


- Wavelength : 1310nm / Distance : 70Km / Mode :Singlemode
- Connector : LC / Data rate : 10.3125 Gbit/s / Core type : Dual Core
- Operating Temperature : 0C ~ 70 C
- 10GBASE-ZR (10G)

Table 26 SFP+ Modules for IU

1.3 System Architecture


The V8106 is a shelf based modular multi-platform L3 switch/GPON OLT. It features highly
flexible hardware configurations with multiple GPON units as well as Gigabit Ethernet units,
so that user can fully customize it for GPON OLT and fiber to the premises network can be
achieved.

With performance of a non-blocking switching capacity of up to 640Gbps switching capacity,


the V8106 provides high speed networking environment.

For GPON, the PON layer is terminated on the interface unit and translated to Ethernet uplink
to be transported through an Ethernet/IP environment. The V8106 can be equipped with up
to 6 Service Interface Units (SIUs) and 2 Network Interface Units (NIUs). For improved sys-
tem reliability, it adopts the design of full redundancy architecture with dual SFUs, PSUs and
FANs.

When dual SFUs are used, the system decides the running mode of SFUs between active
and standby. The above system architecture illustrates SFU redundancy scheme used for the
V8106.

Active SFU is internally linked to all interface units (IUs). They receive traffic from IUs and
update their own Forwarding Database (FDB) in the same manner so that they can keep
identical data to make a forwarding decision. Active SFU can send traffic back to the IUs and
receive traffic from the IUs for address learning.

The power feeding of the V8106 is provided by Power Supply Unit (PSU). Dual PSUs can be
installed to guarantee constant system running. In terms of hardware architecture, the V8106
has two slots for PSUs; the active/active resilient architecture with dual redundant power
supplies provides extremely high redundancy for non-stop operations.

V1.1 Page 16 of 27
Data Sheet
V8106

SIU #1 "1/2.5/10G X 4" per Slot


"1/2.5/10G X 16" per Slot

NIU #1
SIU #2
SFU A
NIU #2
SIU #3 [Active]

"1/2.5/10G X 2"
SIU #4 SFU B
OLP
[Standby]
SIU #5
CIF

SIU #6
Fan unit A
Fan unit B
-48 Vdc PSU_DC A -48 Vdc

Active
-48 Vdc PSU_DC B -48 Vdc
Standby

Figure 11 V8106 System Architecture

1.4 Service Scenario


A PON consists of an Optical Line Termination (OLT) located at the Central Office and a set
of Optical Network Units (ONUs) or Optical Network Terminals (ONTs) located at the cus-
tomers premises. Between them is the optical distribution network (ODN) comprising of fibers
and passive optical splitters or couplers. A splitter is a device that divides an optical signal
into two or more signals. OLT connects the PON to the IP network, controls and manages the
PON clients. ONU (ONT) connects the user specific network to PON. The ONT can be occu-
pied by a single subscriber and also can be a gateway of the local network.

Figure 12 Optical Distribution Network by PON Architecture

The V8106 is a network element, which includes the necessary service adaptation functions
to support the delivery of all types multiple services, such as Ethernet, IP telephony, and video
services.

The PON service is not affected when the ONU is added into and removed from the splitter.

V1.1 Page 17 of 27
Data Sheet
V8106

The V8106 GPON OLT system is one element of this end-to-end solution, however Dasan
Networks is able to provide the complete next generation broadband access network and
video integration solution, where full interoperability is ensured. Up to 128 termination points
for GPON can be attached to an OLT via passive optical splitter.

There are different possible deployment topologies for PON networks, which differentiate
from each other basically from the place the optical fiber is terminated. Depending on the
subscriber type and desired topology to the network, the operator may adopt: FTTH (fiber to
the Home), FTTB (fiber to the Building), FTTN (fiber to the neighborhood) or FTTC (fiber to
the Curb). In case of very high bandwidth requirement per user, scenarios without splitters
offering 2.5Gbps/1.25Gbps or 1.25Gbps/1.25Gbps (downstream/upstream) data rate can
also be deployed by connecting only the single user on a GPON port.

Street Curb or
Cabinet GPON TDM
HDTV
VDSL MDU 2G Mobile
VoIP

xDSL CPEs
2G Network
PC
T1/E1
FTTC / FTTN H645T

Central Office

HDTV

VoIP
ONT
PC
PON OLT
FTTH

EMS/ACS 3G Mobile
Server

3G Network
VoIP Eth
ONU/MDU
H645S
PC
FTTB GPON ATM
STM1

Remote CPE Control via TR-069(CWMP)


ACS ONT

Figure 13 FTTx Service Deployments of GPON OLT

V1.1 Page 18 of 27
Data Sheet
V8106

2 Product Specification
2.1 System

The V8106 supports the following system features:

Shelf with 6/2 slots for SIUs/NIUs for a maximum of interfaces per shelf
640Gbps switching capacity per unit
Service Interface units (SIU):
16-port of GPON interfaces (SIU_GPON16)
Network Interface units (NIU):
4-port of 1/10GbE optical interfaces (NIU_10GE4)
Dual switch fabric units (SFU)
Redundant and load-balanced dual power supply unit (PSU)
Hot Swappable for all plug-in units (SFU, SIU, NIU, PSU, FAN)
LED alarm indicator
Visible alarm indicator

2.2 Physical Specification


V8106 Base Chassis

Number of slots 17
Number of IU slots 6 for SIU, 2 for NIU
Dimensions (W x H x D) 482.6mm x 265.9mm x 280.0mm
Weight 9.1 kg
Minimum free space above shelf 100 mm
Minimum free space below shelf 100 mm
Heat transfer
Air inlet at the right side of the shelf
Air outlet at the left side of the shelf

Operating temperature -25 to 55 C (-13 to 131F)


Storage temperature 40 to 80 C (-40 to 176F)
Operating humidity 0 to 90 % (non-condensing)
DC power voltage 48/60VDC

SFU
Dimensions (W x H x D) 362.0 mm x 30.2 mm x 252.3 mm
Weight 2.0 kg
Ethernet i/f for local management 10/100/1000Base-T (RJ45)
Serial i/f, CLI RS232
Maximum Power Consumption 111.4W (per unit)

SIU_GPON16
Dimensions (W x H x D) 362.0 mm x 20.5 mm x 252.3 mm
Weight 1.3 kg
Interface Parameter 16 x GPON
Maximum Power Consumption 63.4W (per unit)

V1.1 Page 19 of 27
Data Sheet
V8106

NIU_10GE4
Dimensions (W x H x D) 122.3 mm x 33.2 mm x 252.3 mm
Weight 0.6 kg
Interface Parameter 4 x 10GBase-R (SFP+)
Maximum Power Consumption 39.7W (per unit)

Power Supply Unit (PSU)


Dimensions (W x H x D) 122.3 mm x 30.2 mm x 252.3 mm

PSU_DC

DC input voltage -48/60VDC (From -38V to -60VDC)


Input current max. 40A
Output voltage -48VDC
Maximum power 42.6W (with PSU-DC & FAN)

FAN
Dimensions (W x H x D) 31.6 mm x 262.1 mm x 257.9 mm
Weight 1.2 kg (with four Fans)
Number of fans 4pcs per unit (total 8pcs at two FAN units)
Maximum power consumption 42.6W (per unit)

Dust Filter
Dimensions (W x H x D) 11.4 mm x 261.8 mm x 266.0 mm
Weight 0.26 kg

2.3 SW Capabilities

Product Benefits

SFU/PON/FAN/Power Redundancy (1:1)


In Service Software Upgrade (ISSU)
Non Stop Forwarding (NSF) with graceful restart
Network synchronization support Mobile Backhaul over PON (ToD/1PPS, SyncE)
using Clock Interface Unit (*future release)

GPON

Support ITU-T G.984.4 ONT Management & Control Interface (OMCI)


Remote ONT/ONU management
Automatic ONT ranging
GPON OLT Class B+ compliant with ITU-T G.984.2
GPON OLT Class C+ compliant with ITU-T G.984.2
Full-duplex operation
2.488Gbps downstream and 1.244Gbps upstream applications
2.488Gbps continuous-mode transmitter(1.49um-DFB) with automatic output power

V1.1 Page 20 of 27
Data Sheet
V8106

control
BER: under 10-10
Receiving Wavelength: 1260 ~ 1360nm (Typ: 1310nm)
Input sensitivity: Max -28dBm (Measured with a PRBS 223-1 pattern)
Input Saturation Power(Overload): -8dBm (min)
Transmitter wavelength: 1480 ~ 1500nm (Typ: 1490nm)
Mean launched power: +1.5 ~ +4.5dBm (End of life)
Spectral width (-20dB): 1nm (max)
Extinction Ratio: 8.2dB (min)
Support DDM (Digital Diagnostics Monitoring)
Transmission distance: 20km with single-mode fiber
Laser type: laser diode class 1 (defined in IEC 60825-1)

Layer 2

Standard Ethernet Bridging


32K(Max. 288K)s MAC entries
4k active VLANs for 802.1q tagged frame
Port/Subnet/Protocol-based VLAN
VLAN stacking/translation
Spanning tree (STP, RSTP, MSTP)
Link aggregation
Jumbo frame 9k

Layer 3

16k/8k routing entries for IPv4/IPv6


Static routing
RIPv1/v2
OSPFv2
BGPv4
Virtual Router Redundancy Protocol (VRRP)

Multicast

IGMPv1/v2/v3
4k L2 multicast entries
4k L3 multicast entries
IGMP snooping
IGMP proxy
IGMP static join
Multicast VLAN Registration (MVR)

QoS

Traffic scheduling (SP, WRR, DWRR)


8 queues support per port
Port rate limit with the ingress/egress shaping
Conditional rate limiting
Queue mapping according to ingress/egress port, MAC, 802.1q, 802.1p, ToS/DSCP,
IP SA/DA, TCP/UDP

V1.1 Page 21 of 27
Data Sheet
V8106

Access control lists based on port, MAC address, Ether type, IP SA/DA, IP multicast
address, TCP/UDP

Security

802.1x MAC/port based authentication


Storm control for broadcast, multicast and unknown unicast packets
DoS protection
Outband management
IP source guard
Secure Shell (SSH)

Management

Serial/Telnet (CLI)
SNMPv1/v2/v3
DHCP server, client, relay with option 82
Single IP management
RMON
Syslog
Link layer discovery protocol (LLDP)

V1.1 Page 22 of 27
Data Sheet
V8106

3 Product Features and Benefits


3.1 GPON Functionality
The Gigabit Passive Optical Network (GPON) is a high-speed optical access method that has
been defined in ITU-T Recommendation G.984.x GPON carries a two-fold promise of both
higher bit rates and higher efficiency when carrying multiple services over the PON.

The V8106 GPON system provides additional network services at no extra cost, while EPON
systems require additional equipment for TDM. It also offers more available bandwidth for the
entire range of applications. The V8106 introduces a point-to-multipoint concept the several
GPON mechanisms, which enables efficient and flexible FTTx services.

ONT Management over OMCI

OMCI (ONT Management and Control Interface) protocol defined in ITU-T G.984.4, specifies
the format of interactive messages, and the mechanism of information exchange between
the OLT and ONT. Based on the OMCI protocol, GPON terminal management enables an
OAM service to provide a standard way to discover ONT capabilities, and to manage and
control them. OMCI operates on a dedicated bidirectional Port-ID between the management
station and the ONT. In addition, OMCI subdivides the ONT service module, and defines a
series of management entities used for service description.

The V8106 manages and configures various GPON terminals such as ONTs, MDUs or ONUs
through the OMCI protocol. It provides MIB access that replicates the OLT information data-
base and connected ONTs. The management information between OLT and connected ONTs
flow is exchanged via an OMCI channel. The ONTs send upstream a PLOAM message with
the serial number of the ONT. Both PLOAM and OMCI channel provide full control of the
optical network and the management of the customers ONTs.

User Data Encapsulation

GPON Encapsulation Method (GEM) is a scheme of encapsulating user frame data for
transport of the GPON network. Although any type of data can be encapsulated, actual types
depend on service situation. The GEM protocol is used to provide delineation of the user data
frames inside the GPON partitions and the port identification for multiplexing. It can also per-
mit fragmentation of frames over partition boundaries.

PON Aware QoS

QoS schemes in a GPON network. ONT plays a key role in ensuring QoS for all traffic be-
cause it is the ingress and egress point for all network traffic. The ONT can have different
types of service ports, including one or more analog voice ports and one or more Ethernet
ports. It can also perform service classification based on the physical port and map it to
802.1p p-bits. For example, traffic flows from voice ports can be assigned the highest priority.

As part of this service differentiation, the ONT associates different traffic flows with a specific
GPON Encapsulation Method (GEM) Port ID. Each physical port in a given ONT can have a
maximum of eight GEM-ports. 802.1p allows a maximum of eight classes of service (CoS)
based on p-bit marking. The GEM-Port IDs and the p-bit marking together define a specific
service. Traffic from each physical port can be queued up to eight separate queues after
traffic flow classification. Traffic scheduling is done to serve these queues based on their
priority levels.

V1.1 Page 23 of 27
Data Sheet
V8106

In the upstream direction, the traffic is classified at the ONT and then mapped into one out
off 4 T-CONT types supported. All the traffic flows from the ONTs are identified by their GEM-
Port IDs.

The GPON upstream QoS provides the following advantages:


Bandwidth grant is out-of-band (No effect on revenue BW)
SLA based on T-CONT
- No BW effect with having T-CONT per service per ONT
Supports fragmented payloads (good for delay and efficiency)

Dynamic Bandwidth Allocation (DBA)

The V8106 supports both NSR and SR DBA (G.984.3), piggy-back DBRu report mode 0,
including concurrent support for DBR mode 0 and idle GEM mode.

Through Dynamic Bandwidth Allocation (DBA), a PON can be oversubscribed for upstream
traffic. In GPON, DBA algorithms are based on two kinds of methods: Non Status Reporting
(NSR) and Status Reporting (SR).

Status reporting DBA


The OLT requests information about the status of each MDU (or ONU) when applying status
reporting. SR DBA is based on MDU (or ONU) reports via the Dynamic Bandwidth Report
upstream (DBRu) field.

The V8106 uses the piggy-back reporting mode in the DBRu:


Allows MDUs to continuously update the traffic status of a specific T-CONT
Consists of a message that specifies the amount of data waiting in the T-CONT
buffer corresponding to the Alloc-ID that triggered the DBRu transmission
Mode 0: single field reports that use the number of ATM cells or GEM blocks waiting in
the T-CONT buffer as its basic unit

Non status reporting DBA


When applying non status reporting, the OLT determines the bandwidth demands indirectly.
Each MDU sends Idle GEM frames to fill its whole time slot, if there is not enough user data
to be transmitted.

3.2 SIU_GPON16 Functionality

OLT Controller Board

The SIU_GPON16 contains the OLT controller unit that consists of integrated GPON device
(DBA engine, embedded CPU, DDR controller, etc). This unit manages overall GPON pro-
cess and controls the SIU_GPON16 on-board components.

The GPON OLT controller consists of the following components:


Integrated GPON control plane
Optics diagnostics and management
In-band management
Two independent Inter-Integrated Circuit (I2C)
Embedded CPU subsystem switch provides two independent I2C, SPI and UARTs.
Clock Unit
DDR II Controller

V1.1 Page 24 of 27
Data Sheet
V8106

DBA engine for fairness algorithm bandwidth allocation per T-CONT


CBA MAP engine for static T-CONTs bandwidth assignments
ITU-T G.984 compliant MAC

The GPON OLT controller board provides the following features:


Enable low-cost, high density OLTs
Low power consumption
PON aware QoS traffic management features
Flexible Ethernet/GPON interworking
FEC for upstream and downstream
Downstream AES encryption and key exchange process

SIU_GPON16 Backplane
Inventory I2C Primary/Secondary
RJ-45
I2C(for SFP info)
EEPROM SFU
CPLD IBC
Misc control
MGMT

LEDs FLASH SGMII MGMT interface #1


SGMII MUX
FRAM SGMII MGMT interface #2
CPU
DDR3
HBI Interface
UART RS-232 interface
DDR2
DDR2
SDRAM
DDR2
1Gb x2
1Gb
Temp Clock Block Power -48V Power feeding
Block
OPTIC1 (SFP)

OPTIC2 (SFP) Quad 4 x 2.5G Primary SFU


Quad
OPTIC3 (SFP) GPON MAC 4 x 2.5G
Mux/Demux
4 x 2.5G Secondary SFU
2x GPIO
OPTIC4 (SFP)

OPTIC5 (SFP)

OPTIC6 (SFP) Quad 4 x 2.5G Primary SFU


4 x 2.5G
Quad
OPTIC7 (SFP) GPON MAC Mux/Demux
4 x 2.5G Secondary SFU
2x GPIO
OPTIC8 (SFP)

OPTIC9 (SFP)

OPTIC10 (SFP) Quad 4 x 2.5G Primary SFU


Quad
4 x 2.5G
OPTIC11 (SFP) GPON MAC Mux/Demux
4 x 2.5G Secondary SFU
2x GPIO
OPTIC12 (SFP)

OPTIC13 (SFP)

OPTIC14 (SFP) 4 x 2.5G Primary SFU


Quad 4 x 2.5G
Quad
GPON MAC Mux/Demux
OPTIC15 (SFP) 4 x 2.5G Secondary SFU
2x GPIO
OPTIC16 (SFP)

Figure 14 SIU_GPON16 Block Diagram

3.3 NIU_10GE4 Functionality


The NIU_10GE4 contains four 10GbE Base-R SFP+ (10 Gigabit Small Form Factor Plugga-
ble) ports. Each 10GbE port can be equipped with different SFP+ module. Table 26 shows
the available SFP+ module types.

The NIU_10GE4 consists of the following components:


4 x 10GbE interface
Layer 2 switching fabric
10G PHY
SerDes interface
I2C control

V1.1 Page 25 of 27
Data Sheet
V8106

LED control
Power logic

NIU_10GE4 Backplane

Pin Header Inventory I2C Primary/Secondary


EEPROM SFU

CPLD Misc control


PHY

Power
FLASH
LEDs Block
MGMT interface #1
SGMII MUX

CPU
Clock MGMT interface #2
Block
DDR2
SDRAM UART RS-232 interface

SFI
SFP+ #1 2 x 10GBase-KR Primary SFU
XFI Quad
10G PHY
SFI 2 x 10GBase-KR Secondary SFU
SFP+ #2
Quad
SFI 10G PHY
SFP+ #3 2 x 10GBase-KR Primary SFU
XFI Quad
10G PHY
SFI 2 x 10GBase-KR Secondary SFU
SFP+ #4

-48V Power feeding

Figure 15 NIU_10GE4 Block Diagram

V1.1 Page 26 of 27
Data Sheet
V8106

4 Ordering Information
Bases
V8106
19 inches chassis with front access for V8106
- 2-slot Switching Fabric Unit
- 6-slot Service Interface Unit
- 2-slot Network Interface Unit
- 1-slot Off Load Processor Unit
- 1-slot Clock Interface Unit

Switch Fabric Options


V8106_SFU
Switching Fabric Unit for V8106
- Switching capacity: 960Gbps V8106_SFU Blank Panel
- 1-port RS232 for Console Blank Panel for Switching Fabric Unit of V8106
- 1-port GTX for MGMT
- 1-slot microSD

Service Interface Options


V8100_SIU_GPON16
V8106_SIU Blank Panel
- 16-port G-PON Interface Unit for V8100
Blank Panel for Subscriber Interface Unit of V8106
- SFP Optic module

Uplink Interface Options


V8106_NIU_10GE4
V8106_NIU Blank Panel
- 4-port 10G Ethernet Network Interface Unit for V8106
Blank Panel for Network Interface Unit of V8106
- SFP+ Optic module

Power, Fan, etc Options


V8106_PSU_DC V8106_PSU_DC_Blank Panel
V8106_FAN V8106_FAN_Blank Panel
V8106_Dust Filter V8106_CIF Blank Panel
V8106_Cable Duct V8106_OLP Blank Panel

SFP Options SFP+ Options


SFP-GPON-OLT20 SFP+ 10GE-SR
SFP-GE-SX SFP+ 1GE10GE-SR
SFP-GE-LX5 SFP+ 10GE-LR
SFP-GE-LX10 SFP+ 10GE-ER
SFP-GE-LX15 SFP+ 10GE-ZR
SFP-GE-LX20
SFP-GE-LX40

V1.1 Page 27 of 27

You might also like