1 Product Overview
The V8106 is a 6RU height chassis PON Optical Line Termination (OLT) supporting 96 GPON
ports as well as a Layer 3 switch of supporting 8 1/10GbE ports Active Ethernet service. It
terminates the traffic coming from the subscriber lines and consolidates it on one or more
Gigabit Ethernet interfaces towards the metropolitan area.
The V8106 chassis has 17 slots. The 2 slots are reserved for SFU cards for control/switching,
6 slots for service interface card, 2 slots for uplink interface cards, 1 slot for OLP (Offload
Processor) module, 1 slot for clock interface module, as well as 2 slots are reserved for dual
power modules (PSUs), 2 slots for fan modules, 1 slot for dust filter, The V8106 is a carrier-
class equipment, fully redundant, in a modular and high capacity architecture with 6 interface
unit slots. These 6 slots can be used for subscriber interface units and two uplink interface
units for full redundancy architecture.
It is a high-density chassis system that supports up to 12,288 residential and business sub-
scribers with 96 GPON ports (1:128 split ratio). It also provides simultaneous services of
GPON and Gigabit Ethernet. V8106 features flexible and high capacity PON access and
10GbE uplinks, scalability and line rate performance with a 640Gbps non-blocked switch fab-
ric.
The V8106 guarantees equipment-level reliability with full redundancy design concept of
SFU/Power/GPON ports. This is a substantial factor for aggregation switches to perform con-
tinuous traffic forwarding to core network without failure. The PON technology adds new fea-
tures and functionality targeted at improving performance and interoperability, and adds sup-
port for new applications, services, and deployment scenarios.
The PON technology adds new features and functionality targeted at improving performance
and interoperability, and adds support for new applications, services, and deployment sce-
narios. Among these changes are improvements in data rate and reach performance, diag-
nostics, and stand-by mode, to name a few.
The V8106 introduces a point-to-multipoint concept with the PON technology, which enables
a cost-effective FTTx service. The reason why PON is considered as a cost-effective solution
is its usage of a passive splitter rather than an active switching system.
V1.1 Page 3 of 27
Data Sheet
V8106
Service
Interface Unit (SIU)
6 slots
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Dust Filter
Slot 6
FAN FAN
Slot A
Slot B
Slot A Slot B
PSU Slot A CIF PSU Slot B
V1.1 Page 4 of 27
Data Sheet
V8106
*Available in the
OLP unit 1 slot OLP Offload Processor
future
Operating LEDs Indicator for system operating status including power, fault de- -
tection and booting state.
CONSOLE CLI access to configure the functions for system operation RJ45 (RS232)
MGMT Out of band TMN-OS Interface RJ45
SD Memory Sta- Indicator for SD memory status -
tus LED
V1.1 Page 5 of 27
Data Sheet
V8106
V1.1 Page 6 of 27
Data Sheet
V8106
V1.1 Page 7 of 27
Data Sheet
V8106
SIU_GPON16
Operating LEDs Indicator for system operating status including power, fault de- -
tection and booting state.
Connections 16 x GPON ports SFP
L/A LEDs Indicator for ports link status and traffic activity. -
V1.1 Page 8 of 27
Data Sheet
V8106
NIU_10GE4
Operating LEDs
Operating LEDs Indicator for system operating status including power, fault de- -
tection and booting state.
L/A LEDs Indicator for ports link status and traffic activity. -
Connections 4 x 10GBase-R ports. SFP+
V1.1 Page 9 of 27
Data Sheet
V8106
L/A Green On The port link is up and the Ethernet transmit rate is 10Gbps.
Blinking A sending or receiving activity is present on the Ethernet port at
10Gbps.
Amber On The port link is up and the Ethernet transmit rate is 1Gbps.
Blinking A sending or receiving activity is present on the Ethernet port at 1Gbps.
Off The port link is down.
The power supply unit (PSU) feeds the proper power voltage to the V8106 and power con-
nector (DC type) for main power supply is located on the front panel of the PSU. For redun-
dant power feeding, the second PSU has to be used.
All plug-in units in the V8106 are supplied with a voltage of -48/60V regulated by the PSU.
V1.1 Page 10 of 27
Data Sheet
V8106
The fan unit is connected to the backplane of the shelf and fed with a voltage of 12V. The
LED indicators on the fan unit show the operating status of the fan.
The fans are controlled in accordance with the measured temperature inside the system. The
temperature sensor is located in the system, and the measured values are evaluated and the
operation of the fan controlled accordingly.
V1.1 Page 11 of 27
Data Sheet
V8106
V1.1 Page 12 of 27
Data Sheet
V8106
Bases
Name Description Maximum
quantity
Interface Units
Name Description Maximum
quantity
V1.1 Page 13 of 27
Data Sheet
V8106
SFP Options
The following different optical SFP modules are available and can be inserted into the dedi-
cated slots of the SIU. Each SFP module contains one port.
V1.1 Page 14 of 27
Data Sheet
V8106
Other types of SFP module can be also available upon customer request.
i
SFP+ Options
The following different optical SFP+ modules are available and can be inserted into the ded-
icated slots of the NIU. Each SFP+ module contains one port.
V1.1 Page 15 of 27
Data Sheet
V8106
For GPON, the PON layer is terminated on the interface unit and translated to Ethernet uplink
to be transported through an Ethernet/IP environment. The V8106 can be equipped with up
to 6 Service Interface Units (SIUs) and 2 Network Interface Units (NIUs). For improved sys-
tem reliability, it adopts the design of full redundancy architecture with dual SFUs, PSUs and
FANs.
When dual SFUs are used, the system decides the running mode of SFUs between active
and standby. The above system architecture illustrates SFU redundancy scheme used for the
V8106.
Active SFU is internally linked to all interface units (IUs). They receive traffic from IUs and
update their own Forwarding Database (FDB) in the same manner so that they can keep
identical data to make a forwarding decision. Active SFU can send traffic back to the IUs and
receive traffic from the IUs for address learning.
The power feeding of the V8106 is provided by Power Supply Unit (PSU). Dual PSUs can be
installed to guarantee constant system running. In terms of hardware architecture, the V8106
has two slots for PSUs; the active/active resilient architecture with dual redundant power
supplies provides extremely high redundancy for non-stop operations.
V1.1 Page 16 of 27
Data Sheet
V8106
NIU #1
SIU #2
SFU A
NIU #2
SIU #3 [Active]
"1/2.5/10G X 2"
SIU #4 SFU B
OLP
[Standby]
SIU #5
CIF
SIU #6
Fan unit A
Fan unit B
-48 Vdc PSU_DC A -48 Vdc
Active
-48 Vdc PSU_DC B -48 Vdc
Standby
The V8106 is a network element, which includes the necessary service adaptation functions
to support the delivery of all types multiple services, such as Ethernet, IP telephony, and video
services.
The PON service is not affected when the ONU is added into and removed from the splitter.
V1.1 Page 17 of 27
Data Sheet
V8106
The V8106 GPON OLT system is one element of this end-to-end solution, however Dasan
Networks is able to provide the complete next generation broadband access network and
video integration solution, where full interoperability is ensured. Up to 128 termination points
for GPON can be attached to an OLT via passive optical splitter.
There are different possible deployment topologies for PON networks, which differentiate
from each other basically from the place the optical fiber is terminated. Depending on the
subscriber type and desired topology to the network, the operator may adopt: FTTH (fiber to
the Home), FTTB (fiber to the Building), FTTN (fiber to the neighborhood) or FTTC (fiber to
the Curb). In case of very high bandwidth requirement per user, scenarios without splitters
offering 2.5Gbps/1.25Gbps or 1.25Gbps/1.25Gbps (downstream/upstream) data rate can
also be deployed by connecting only the single user on a GPON port.
Street Curb or
Cabinet GPON TDM
HDTV
VDSL MDU 2G Mobile
VoIP
xDSL CPEs
2G Network
PC
T1/E1
FTTC / FTTN H645T
Central Office
HDTV
VoIP
ONT
PC
PON OLT
FTTH
EMS/ACS 3G Mobile
Server
3G Network
VoIP Eth
ONU/MDU
H645S
PC
FTTB GPON ATM
STM1
V1.1 Page 18 of 27
Data Sheet
V8106
2 Product Specification
2.1 System
Shelf with 6/2 slots for SIUs/NIUs for a maximum of interfaces per shelf
640Gbps switching capacity per unit
Service Interface units (SIU):
16-port of GPON interfaces (SIU_GPON16)
Network Interface units (NIU):
4-port of 1/10GbE optical interfaces (NIU_10GE4)
Dual switch fabric units (SFU)
Redundant and load-balanced dual power supply unit (PSU)
Hot Swappable for all plug-in units (SFU, SIU, NIU, PSU, FAN)
LED alarm indicator
Visible alarm indicator
Number of slots 17
Number of IU slots 6 for SIU, 2 for NIU
Dimensions (W x H x D) 482.6mm x 265.9mm x 280.0mm
Weight 9.1 kg
Minimum free space above shelf 100 mm
Minimum free space below shelf 100 mm
Heat transfer
Air inlet at the right side of the shelf
Air outlet at the left side of the shelf
SFU
Dimensions (W x H x D) 362.0 mm x 30.2 mm x 252.3 mm
Weight 2.0 kg
Ethernet i/f for local management 10/100/1000Base-T (RJ45)
Serial i/f, CLI RS232
Maximum Power Consumption 111.4W (per unit)
SIU_GPON16
Dimensions (W x H x D) 362.0 mm x 20.5 mm x 252.3 mm
Weight 1.3 kg
Interface Parameter 16 x GPON
Maximum Power Consumption 63.4W (per unit)
V1.1 Page 19 of 27
Data Sheet
V8106
NIU_10GE4
Dimensions (W x H x D) 122.3 mm x 33.2 mm x 252.3 mm
Weight 0.6 kg
Interface Parameter 4 x 10GBase-R (SFP+)
Maximum Power Consumption 39.7W (per unit)
PSU_DC
FAN
Dimensions (W x H x D) 31.6 mm x 262.1 mm x 257.9 mm
Weight 1.2 kg (with four Fans)
Number of fans 4pcs per unit (total 8pcs at two FAN units)
Maximum power consumption 42.6W (per unit)
Dust Filter
Dimensions (W x H x D) 11.4 mm x 261.8 mm x 266.0 mm
Weight 0.26 kg
2.3 SW Capabilities
Product Benefits
GPON
V1.1 Page 20 of 27
Data Sheet
V8106
control
BER: under 10-10
Receiving Wavelength: 1260 ~ 1360nm (Typ: 1310nm)
Input sensitivity: Max -28dBm (Measured with a PRBS 223-1 pattern)
Input Saturation Power(Overload): -8dBm (min)
Transmitter wavelength: 1480 ~ 1500nm (Typ: 1490nm)
Mean launched power: +1.5 ~ +4.5dBm (End of life)
Spectral width (-20dB): 1nm (max)
Extinction Ratio: 8.2dB (min)
Support DDM (Digital Diagnostics Monitoring)
Transmission distance: 20km with single-mode fiber
Laser type: laser diode class 1 (defined in IEC 60825-1)
Layer 2
Layer 3
Multicast
IGMPv1/v2/v3
4k L2 multicast entries
4k L3 multicast entries
IGMP snooping
IGMP proxy
IGMP static join
Multicast VLAN Registration (MVR)
QoS
V1.1 Page 21 of 27
Data Sheet
V8106
Access control lists based on port, MAC address, Ether type, IP SA/DA, IP multicast
address, TCP/UDP
Security
Management
Serial/Telnet (CLI)
SNMPv1/v2/v3
DHCP server, client, relay with option 82
Single IP management
RMON
Syslog
Link layer discovery protocol (LLDP)
V1.1 Page 22 of 27
Data Sheet
V8106
The V8106 GPON system provides additional network services at no extra cost, while EPON
systems require additional equipment for TDM. It also offers more available bandwidth for the
entire range of applications. The V8106 introduces a point-to-multipoint concept the several
GPON mechanisms, which enables efficient and flexible FTTx services.
OMCI (ONT Management and Control Interface) protocol defined in ITU-T G.984.4, specifies
the format of interactive messages, and the mechanism of information exchange between
the OLT and ONT. Based on the OMCI protocol, GPON terminal management enables an
OAM service to provide a standard way to discover ONT capabilities, and to manage and
control them. OMCI operates on a dedicated bidirectional Port-ID between the management
station and the ONT. In addition, OMCI subdivides the ONT service module, and defines a
series of management entities used for service description.
The V8106 manages and configures various GPON terminals such as ONTs, MDUs or ONUs
through the OMCI protocol. It provides MIB access that replicates the OLT information data-
base and connected ONTs. The management information between OLT and connected ONTs
flow is exchanged via an OMCI channel. The ONTs send upstream a PLOAM message with
the serial number of the ONT. Both PLOAM and OMCI channel provide full control of the
optical network and the management of the customers ONTs.
GPON Encapsulation Method (GEM) is a scheme of encapsulating user frame data for
transport of the GPON network. Although any type of data can be encapsulated, actual types
depend on service situation. The GEM protocol is used to provide delineation of the user data
frames inside the GPON partitions and the port identification for multiplexing. It can also per-
mit fragmentation of frames over partition boundaries.
QoS schemes in a GPON network. ONT plays a key role in ensuring QoS for all traffic be-
cause it is the ingress and egress point for all network traffic. The ONT can have different
types of service ports, including one or more analog voice ports and one or more Ethernet
ports. It can also perform service classification based on the physical port and map it to
802.1p p-bits. For example, traffic flows from voice ports can be assigned the highest priority.
As part of this service differentiation, the ONT associates different traffic flows with a specific
GPON Encapsulation Method (GEM) Port ID. Each physical port in a given ONT can have a
maximum of eight GEM-ports. 802.1p allows a maximum of eight classes of service (CoS)
based on p-bit marking. The GEM-Port IDs and the p-bit marking together define a specific
service. Traffic from each physical port can be queued up to eight separate queues after
traffic flow classification. Traffic scheduling is done to serve these queues based on their
priority levels.
V1.1 Page 23 of 27
Data Sheet
V8106
In the upstream direction, the traffic is classified at the ONT and then mapped into one out
off 4 T-CONT types supported. All the traffic flows from the ONTs are identified by their GEM-
Port IDs.
The V8106 supports both NSR and SR DBA (G.984.3), piggy-back DBRu report mode 0,
including concurrent support for DBR mode 0 and idle GEM mode.
Through Dynamic Bandwidth Allocation (DBA), a PON can be oversubscribed for upstream
traffic. In GPON, DBA algorithms are based on two kinds of methods: Non Status Reporting
(NSR) and Status Reporting (SR).
The SIU_GPON16 contains the OLT controller unit that consists of integrated GPON device
(DBA engine, embedded CPU, DDR controller, etc). This unit manages overall GPON pro-
cess and controls the SIU_GPON16 on-board components.
V1.1 Page 24 of 27
Data Sheet
V8106
SIU_GPON16 Backplane
Inventory I2C Primary/Secondary
RJ-45
I2C(for SFP info)
EEPROM SFU
CPLD IBC
Misc control
MGMT
OPTIC5 (SFP)
OPTIC9 (SFP)
OPTIC13 (SFP)
V1.1 Page 25 of 27
Data Sheet
V8106
LED control
Power logic
NIU_10GE4 Backplane
Power
FLASH
LEDs Block
MGMT interface #1
SGMII MUX
CPU
Clock MGMT interface #2
Block
DDR2
SDRAM UART RS-232 interface
SFI
SFP+ #1 2 x 10GBase-KR Primary SFU
XFI Quad
10G PHY
SFI 2 x 10GBase-KR Secondary SFU
SFP+ #2
Quad
SFI 10G PHY
SFP+ #3 2 x 10GBase-KR Primary SFU
XFI Quad
10G PHY
SFI 2 x 10GBase-KR Secondary SFU
SFP+ #4
V1.1 Page 26 of 27
Data Sheet
V8106
4 Ordering Information
Bases
V8106
19 inches chassis with front access for V8106
- 2-slot Switching Fabric Unit
- 6-slot Service Interface Unit
- 2-slot Network Interface Unit
- 1-slot Off Load Processor Unit
- 1-slot Clock Interface Unit
V1.1 Page 27 of 27