CONTROL RELAY
DRAGON 1 series
DISTRIBUTION GRIDS and
INDUSTRIAL OBJECTS
ROCON plc DRAGON 1
Catalogue
ROCON plc
ROCON plc DRAGON 1
Catalogue
4. Technical data
RMI402 D1
RMI401 D1
RMI421 D1
REA421 D1
RTI402 D1
RFI401 D1
ANSID1
RFI421 D1
RLI402 D1
ANSI
RFI411
Technical data
1 Protection
1 2 3 4 5 6 7 8 9
3 Edition 5/2015 3 3/
ROCON plc
ROCON plc DRAGON 1
Catalogue
RMI402 D1
RMI401 D1
RMI421 D1
REA421 D1
RTI402 D1
RFI401 D1
RFI411 D1
RFI421 D1
RLI402 D1
ANSI
Technical data
1 Protection
1 2 3 4 5 6 7 8 9
4 Edition 5/2015 3 3/
ROCON plc
ROCON plc DRAGON 1
Catalogue
RMI402 D1
RMI401 D1
RMI421 D1
REA421 D1
RTI402 D1
RFI401 D1
RFI411 D1
RFI421 D1
RLI402 D1
ANSI
Technical data
1 Protection 1 2 3 4 5 6 7 8 9
1.39 Directional underpower 32U
protection
1.40 Motor differential protection*** 87M
1.41 Transformer differential 87T
protection***
1.42 Low Impedance restricted Earth 87N
fault protection
1.43 Line differential protection 87L
1.44 User defined logical functions
1.45 Setting groups 4 4 4 4 4 4 4 4 4
2 Monitoring and control
2.1 Circuit-breaker life time
monitoring
2.2 Current circuit symmetry 87
monitoring
2.3 Fuse failure monitoring 60
2.4 Voltage circuit supervision
2.5 Trip circuit supervision TC74
2.6 Minimum and maximum values
monitoring
2.7 local/remote control
2.8 Interlocking
2.9 Lockout logic 86
2.10 Clockwise and anticlockwise
phase rotation
2.11 Synchronism/energizing check 25
2.12 Signalization
3 Measurement and
calculation
3.1 Phase current true RMS
st
3.2 Fundamental (1 harmonic)
current
3.3 Residual current 3Io
3.4 Current in the neutral
3.5 Positive sequence current I1
3.6 Negative sequence current I2
nd
3.7 2 harmonic current
th
3.8 THD up to 19 harmonic - 2kHz
sampling rate
3.9 Phase voltage true RMS
5 Edition 5/2015 3 3/
ROCON plc
ROCON plc DRAGON 1
Catalogue
RMI 402 D1
RMI 401 D1
RMI 421 D1
REA421 D1
RTI 402 D1
RFI 401 D1
RFI 411 D1
RFI 421 D1
RLI 402 D1
ANSI
Technical data
Measurement and
calculation
3.10 Phase to phase voltage true RMS
st
3.11 Fundamental (1 harmonic)
voltage
3.12 Positive sequence voltage U1
3.13 Neutral Voltage displacement 3Uo
3.14 Negative sequence voltage U2
3.15 Frequency f
3.16 Rate of change of frequency df/dt
3.17 P, Q, S and Ep, Eq
3.18 Current - voltage angle
4 Recorders
4.1 Event and fault recorder
4.2 Disturbance recorder
5 Additional functions
5.1 PC-based configuration & settings
Man Machine interface (MMI)
program
5.3 Time Synchronization data
channel
5.4 Self-supervision with internal
event list
6 Hardware **
6.1 Power supply 24 220VDC
-20% +10%
48 240VAC -20% + 10%
6.2 Phase Current inputs 1A, 5 A
3/2 2 3/2 3 3 3 3 3
0.1 40 In
6.3 Residual/neutral current input
Range 1()0.140 Ion - 5A, 1A 1 1 1 1 1 1 1 1
Range 2() 0.01 1.6 Ion 5A, 1A
6.4 Voltage inputs - 57.7/63.5 V , 3 3 3
100/110 V (ph-ph)
6.5 Residual Voltage input 3Uo/Ubus,
1 1
100/110 V
6.6 Binary inputs 5 5 10 10 10 5 5
24 - 220 - 30% +20% VDC 2mA 21 21
21 21 21 21 21 21
and VAC (optional)
6.7 Binary outputs (electromechanical 4 4 8 8 8 4 4
12 12
relays) 16 16 16 16 16 16
6 Edition 5/2015 3 3/
ROCON plc
ROCON plc DRAGON 1
Catalogue
RMI 402 D1
RMI 401 D1
RMI 421 D1
REA421 D1
RTI 402 D1
RFI 411 D1
RFI 401 D1
RFI 421 D1
RLI 402 D1
ANSI
Technical data
6 Hardware **
6.8 Real time clock
6.9 LAN communication interface -
via Optical Ethernet 100BASE-FX
FX ST FO MM1300 nm
6.10 LAN communication interface -
via Optical Ethernet 100BASE-FX +
100BASE-FX 2xST FO MM1300nm,
suitable for PRP redundancy
6.11 LAN communication interface
with internal switch - via Optical
Ethernet 100BASE-FX + 100BASE-
FX 2xST FO MM1300 nm,
intended for HSR/RSTP
redundancy
6.12 LAN communication interface via
electrical RS485
6.13 Optical interface for RTBs MM 820
nm
6.14 Optical front interface for portable
PC connection
6.15 Keypad and 2x16 digits LCD
display
6.16 LED indication 9 9 9 9 9 9 9 9 9
6.17 Dimensions 170/218/59,2 mm
6.18 Weight 0.8 kg
7 LAN Communication
protocols
7.1 IEC 61850
7.2 IEC 60870-5-103
7.3 MODBUS
8 Remote Terminal RTB RTB RTB RTB RTB RTB RTB
1 1 1 1 1 1 1
Blocks RTB ****
standard function
optional function
** RFI 401_D1 and RMI 401_D1 over/undervoltage protection are with 2 stages
***Every set of Transformer and Motor differential protection includes two separate
devices DRAGON1. The slave allows to be completed (optionally) with RTB1.
**** RTB1 provides additionally 16 BI and 12 BO
RTB1 21, 17 - the device and the number of DI/DO in a blue color are optional
7 Edition 5/2015 3 3/
ROCON plc
ROCON plc DRAGON 1
Catalog
ROCON plc
ROCON plc DRAGON 1
Catalog
Reactive power relay for isolated healthy phases increase and the related
networks and options: (90) or (- capacityes are charged.
90) max sensitivity angle; If the fault is permanent (non-transient)
in nature, only the initial fault transient
5.1.5 Conductance / Susceptance earth in the current and voltage is important
fault protection ANSI 21YN for measuring.
Earth faults in isolated and The initial transient in the faulted
compensated networks are often feeder is characterized with very short
occurs and are complicated for and high peak values spikes of residual
identification especially in case of high current (3Io) and voltage (3Uo). The
resistance earth faults. transient earth fault protection is
The conductance and susceptance realized through the the residual
algorithms are intended respectively current and voltage measurement and
for compensated and isolated the transients of 3Io and 3Uo analyzing
networks and are more efficient in case with predefined criteria. The
of high-resistance earth faults. measurement is realized with a very
The applied in DRAGON 1 adaptive high sampling rate of 4kHz.
algorithm is especially suitable for the
systems with considerable unbalance 5.1.7 Intermittent Earth fault protection
(for 3I0, 3Uo) during normal operation. (IGFP) ANSI 67NIEF
This function is intended to detect
5.1.6 Transient earth fault protection faults which are provoked by the
(TGFP) ANSI 67NIEF deterioration of HV cable insulation
TFGP function is dedicated to operate either due to mechanical stress or to
in case of transient earth faults insulation material aging where water
occurring in distribution networks. It is or moisture penetrates into the cable
suitable mainly for isolated and insulation. This can lead to the
compensated networks. insulation voltage withstand reduction
Earth faults generate transients in and to series of cable insulation
currents and voltages. There are breakdowns. ITGF is suitable
several factors that affect the compensated network. The
magnitude and frequency of these intermittent phenomena are
transients, such as the fault moment characterized with very short transients
regarding the voltage wave, fault of rapid changes in form of spikes in
location, fault resistance and the residual current (3Io) and in residual
parameters of the feeders and the voltage (3Uo).
supplying transformers. The voltage of The function uses measured values of
the faulty phase decreases and the 3Io and 3Uo and detects repeatedly
corresponding capacity is discharged transients through the predefined
into the earth. The voltages of the criteria.
ROCON plc
ROCON plc DRAGON 1
Catalog
ROCON plc
ROCON plc DRAGON 1
Catalog
ROCON plc
ROCON plc DRAGON 1
Catalog
ROCON plc
ROCON plc DRAGON 1
Catalog
isolation of all the fault current sources quartz stable reference time and from
is necessary for a successful this the deviation of the cycle duration
autoreclose with the network-end of the voltage signal is ascertained.
circuit breaker. In case of a vector shift the zero
The positive-sequence undervoltage is passage occurs either earlier or later.
also available during asymmetrical The established deviation of the cycle
faults. It is more appropriate criterion duration is in compliance with the
for detecting the risk of loss of vector shift angle.
synchronism than, for example, the
lowest phase to phase voltage. 5.1.24 Underfrequency protection
Motor stalling and failure to start can (DTUF) ANSI 81U
also lead to a continuous undervoltage. DTUF is mainly designed to protect
For that reason the positive sequence network against the abnormal low
undervoltage can be applied as a frequency condition. DTUF is applicable
backup protection against the motor in all situations where a reliable
stall condition. detection of a low fundamental voltage
PSUV is realized with two separate and frequency is needed. The low
independent stages, i. e. each stage is fundamental frequency in the power
separate functional module with its system indicates that the generated
own settings, configuration power is too low to meet the demands
parameters, internal variables and of the load connected to the power
process points. grid. As a result, the system can be split
into two parts and one of them can
5.1.23 Voltage Vector shift protection have an excess load and the other -
(VVS) deficit. DTUF uses the positive
The voltage vector shift protection is sequence voltage to measure the
designed to detect rapid changes in frequency reliably and accurately.
the vector of the phase voltages during DTUF is realized with four separate and
system failure. independent stages, i. e. each stage is
This function provides anti-islanding separate functional module with its
grid connection protection. It is own settings, configuration parameters
suitable in cases of genset (wind farm, and internal variables.
solar park etc.) disconnection from the
power system. 5.1.25 Over frequency protection
When an island occurs the sudden load (DTOF) ANSI 81O
change is observed and the waveform The overfrequency function is mainly
of the voltage is changed. The function designed to protect network against
measures the cycle duration. A new the abnormal high frequency
measuring is started at each voltage conditions. DTOF is applicable in all
zero passage. The measured cycle situations where a detection of a high
duration is internally compared with a fundamental voltage frequency is
ROCON plc
ROCON plc DRAGON 1
Catalog
needed. The deviation of the frequency actions to secure the power system
from the rated system frequency integrity.
indicates unbalance between the RoCoF is realized with four separate
generated power and the load and independent stages, i. e. each
demand. If the available generation is stage is separate functional module
too much compared to the with its own settings, configuration
consumption by the load connected to parameters and internal variables.
the power system, then the system
frequency is above the rated value. The 5.1.27 Starting time supervision
over-frequency protection function is protection (STS) ANSI48
usually applied to decrease generation. Starting time supervision function is
Another possible application is the intended to protect the motor from
detection of unintended island too long starting process. The function
operation of distributed generation supervises the motor status and
and some consumers. In the island, detects the current at the time of
there is low probability that the movement, the beginning of the
generated power is the same as starting process and monitors its
consumption and the detection of high duration.
frequency can be an indication for High voltage motors can quickly be
island mode of operation. heated above their thermal limits if the
DTOF is realized with four separate and duration of the starting attempt is too
independent stages, i. e. each stage is long due to excessive voltage dips
separate functional module with its during motor starting, excessive load
own settings, configuration parameters torques, or blocked rotor conditions.
and internal variables. STS can be used to supplement the
overload protection.
5.1.26 Rate of change of frequency
protection (RoCoF) ANSI 81R 5.1.28 Loss of load protection (LLP)
RoCoF protection is intended in case The protection is suitable for detection
when the rapid change of the of sudden loss of load due to the
fundamental power system voltage disconnection or the coupling
frequency should be detected. The mechanism failure. This situation has to
frequency gradient can be used for be stoped becauce of the possibility to
both increasing and decreasing damage the coupling mechanism or to
phenomena. create the problems in the
This function often in combination with technological process.
underfrequency protection provides
load shedding, generator shedding and 5.1.29 Number of starts limitation
generator boosting, especially in protection (NSL) ANSI66
smaller power systems where the loss NSL is mainly designed to detect
of a large generator requires quick abnormal conditions connected with
ROCON plc
ROCON plc DRAGON 1
Catalog
ROCON plc
ROCON plc DRAGON 1
Catalog
ROCON plc
ROCON plc DRAGON 1
Catalog
5.1.36 Line differential protection (LDP) 5.1.37 User defined logical functions
87L This is a special feature which provides
LDP operation principle is a differential the customer with the possibility to
protection with bias characteristics as a create mathematic-logic equations for
setting. LDP is mainly designed for the development of new functions
double sourced medium voltage based on the available hardware.
feeders but also is suitable for short HV
lines. The function is normaly used as a 5.1.38 Setting groups
main protection against all types of DRAGON 1 includes up 4 selectable
short circuits and is independent from setting groups. One of them is into
the type of the neutral earthing. operation. Transition from one setting
The protection function calculates group to another can be done during
differential currents as a vector sum of the operation of the device. Changing
the instant values by respective phase the groups can be achieved locally
current values measured by the trough the front device panel),
protection devices mounted on each remotely through PC running Man
end of the protected line. Bias currents Machine Interface (MMI) service
are calculated as a module sum of the program, by a command from
measured phase currents. Substation Automation System
Each device on the both ends of the Workstation or via dedicated binary
line compares measured and received inputs.
values. If the difference is bigger than Function parameters of each setting
the set value - protection will start to group can be edited during the normal
operate. All calculations of the line operation of the device, even the
running setting group.
ROCON plc
ROCON plc DRAGON 1
Catalog
Each setting group has its own current transformer circuits can cause
number. This number is used for unwanted operation of differential,
identification of the group while it has earth fault and negative sequence
to be uploaded for editing or for overcurrent protection. The function
activation. calculates the instant value of ratio
Imin/Imax and if the measured value
5.2 Monitoring and control becomes smaller than the settings the
output signal will be issued.
ROCON plc
ROCON plc DRAGON 1
Catalog
Symmetrical conditions are checked by currents and voltages for forward and
means of comparison between the reverse direction of the active power
smallest and the biggest phase voltage for the last elapsed period (with a time
values. stamp) and for the active period are
calculated and recorded in the device.
5.2.5 Trip circuit supervision (TCS) Current and voltage thresholds are
The function is intended to give a monitored under/over which the
warning signal in case of failure in the min/max values will not be registered.
tripping circuits irrespective of the
circuit breaker position open or close. 5.2.7 CB local/remote control
The function is applicable for all type of CB control function (CB local/remote
circuit breakers. For the operation of closing and opening by the operational
the function a single binary input and staff can be performed from the device
an external resistor have to be used. only by a command received remotely
The current in the circuit consisting of from SAS/SCADA or locally from the
IED optical input, external resistor and push buttons "I" and "O" on the device
trip coil has to be enough for activating front panel. To enable a command the
the binary input. relay checks the correctness of the
During the binary output operation conditions (the CB status and
(trip command) a special software task local/remote control switch, blocking
will block the activation of the warning conditions etc.). If the necessary
signal. If the output contact remains conditions are not fulfilled the
continuously in close position the operation is cancelled and an
corresponding massage will be explanatory text will be displayed.
activated.
5.2.8 Interlocking
5.2.6 Minimum Maximum values The function allows only commands
monitoring verified by the interlocking logic.
The minimum and maximum primary
values for each of the phase currents Ix, 5.2.9 Lockout logic (ANSI 86)
each of phase-phase voltages (for the This function provides different type of
types with voltage inputs) for a period trip command algorithms with
of 24 hours, 1 mount and 1 year are definite time delay and with
monitored. It means that in the device latching/locking of the trip command.
there are min/max values for the last All binary outputs could be set to use
elapsed period with a time stamp and the Lockout logic.
the min/max values for the active There are two different modes of
period. tripping signal operation:
The max values for forward/reverse Impulse type with the
active/reactive power (for the types minimum tripping time duration
with voltage inputs) and min/max
ROCON plc
ROCON plc DRAGON 1
Catalog
ROCON plc
ROCON plc DRAGON 1
Catalog
ROCON plc
ROCON plc DRAGON 1
Catalog
the unit display, memorized in the SAS DRAGON 1 series gives the possibility
or uploaded in the PC with running for redundancy with application of the
MMI program. latest types of IEC 61850 Redundancy
Communication Protocols PRP, HSR
5.4.2 Disturbance recorder and RSTP for star and ring topology.
If changes in the normal operating
conditions appeared they can be 5.6.1 Rapid spanning tree protocol (RSTP)
memorized by the Disturbance In the case when network offers
recorder function, implemented in the redundant links the application of the
device. The recorded values are Rapid Spanning Tree Protocol (RSTP) is
measured with sampling frequency of suitable.
1kHz.
The records from the Disturbance 5.6.2 High availability seamless
redundancy (HSR)- IEC 62439-3 Clause 5
recorder function can be transferred to
IEC 62439-3 Clause 5 defines another
the device with running MMI service
redundancy in the nodes solution with
program local SAS, portable PC,
HSR, in which a switch element is
Dispatch centre etc.
integrated in each device.
HSR applies parallel operation principal
5.5 Communication to a single ring, treating the two
DRAGON 1 IEDs are intended to be directions as two virtual LANs. This
used practically with all standard allows a significant reduction in
communication protocols, which are in hardware costs because no switches
use by SCADA including IEC 61850 and are used and only one link is added. All
GOOSE. nodes of the ring must be switching
nodes, i.e. they have two ports and
5.6 Redundancy protocols integrate a switch element.
Redundancy was a major hurdle, since
the lack of a commonly accepted 5.6.3 Parallel redundancy protocol (PRP)
redundancy protocol prompted PRP (IEC 62439-3 Clause 4) specifies
manufacturers to market incompatible that each device is connected in
proprietary solutions. parallel to two local area networks of a
similar topology.