Ecler Amic24 Processor Service Manual
Ecler Amic24 Processor Service Manual
Ecler Amic24 Processor Service Manual
SERVICE MANUAL
SERVICE MANUAL AMIC24
INDEX
- BLOCK DIAGRAM
- SCHEMATICS
- TECHNICAL CHARACTERISTICS
- WIRING DIAGRAM
- MECHANICAL DIAGRAM
- PACKING DIAGRAM
PARTS LIST: PRINTED CIRCUIT 11.1198.03.00
VERIFICATION PROCESS
product:
BURNING TEST
Leave the unit connected to its nominal mains voltage during 24 hours.
Preliminary:
Connect the tester probes between the mains ground contact and the units backside main ground test
point. When applying a 10A current, verify that the ground impedance is lower than 01.
Connect the electrical insulation tester probes between the mains outlet ground contact and both shorted
mains input poles.
Adjust the testers current limit down to 10mA.
Apply 1500Vac during 5 seconds.
The units insulation should be able to resist this voltage, without generating spurious sparks or a
sparkover effect, and the tester may not detect any malfunction.
CAUTION: Do not disconnect nor touch the test probes until the test has finished completely!
QUALITY CONTROL
All mechanical parts should be visually revised, in order to detect scratches on the unit's painting; all
screws should be on their place, correctly tight and unmarked. Check out the unit's general presentation.
PRELIMINARY
VERIFICATION
TECHNICAL CHARACTERISTICS
product:
Processing:
A/D & D/A 24 bit, 48kHz
DSP 48 bits
Latency 0.585ms
Compressor / Limiter:
Threshold from -48dBV to +12dBV
Ratio 1:1 to :1 (limiter)
Attack time Auto or from 0.1ms to 150ms.
Release time Auto or from 1ms to 5s.
Analog Volume remote control (0-10VDC) 0V.= no attenuation (0dB) / +10V. = full attenuation (-.)
Dimensions 482.6x44x198mm
Weight 2.25 kg.
6
12
2
6
7
4
12
1
15
1
10
1
5
6 16
1
1
1
13
3 1
1 4
4
8
Jordi Folch 080730 F11-08 AMIC24 11
ECLER drawn:
approved:
date:
title:
project:
MECHANICAL DIAGRAM
product:
2
1
1
4
11
2
8
1
3
1
5
2
4
1
9
1
PACKING DIAGRAM
product: