Bridge Engineering Project: Information Given

This document provides design parameters and calculations for a 30m bridge with 10 parallel girders. Key parameters include: a live load of HS20/4.27m, a slab thickness of 0.2m, and girder material of A992M steel with Fy=345MPa. Design calculations determine the maximum moment of 1116kN.m/m can be resisted by a W1000x371 section, and the maximum shear of 581.34kN is below the section's shear capacity of 3558kN. Deflection criteria are also satisfied.

Uploaded by

shamsukarim2009
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views5 pages

Bridge Engineering Project: Information Given

This document provides design parameters and calculations for a 30m bridge with 10 parallel girders. Key parameters include: a live load of HS20/4.27m, a slab thickness of 0.2m, and girder material of A992M steel with Fy=345MPa. Design calculations determine the maximum moment of 1116kN.m/m can be resisted by a W1000x371 section, and the maximum shear of 581.34kN is below the section's shear capacity of 3558kN. Deflection criteria are also satisfied.

Uploaded by

shamsukarim2009
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 5

Bridge Engineering Project

Information given:

Bridge Span L = 30m

Clear Width = 15m

Live Load = HS20/4.27m

Sc/c =1.85m

Wcu = 24KN/m3

Wws = 23KN/m3

Fy = 420Mpa

Fc = 35Mpa

Wearing surface thickness = 0.07m

Steel type used for (W) structural shape A992M: Fy = 345Mpa, Fu =


448Mpa

The bridge will consist of 10 parallel girders as shown.

Design to be based on 2x106 cycles of loading.


Design Procedure
Slab thickness:

S+ 3.048
min h = 30 0.165m where S= Sc/c= 1.85

= 0.163 < 0.165 use h =0.2m

Assume girder weight and diaphragms = 1155N/m

WDC = 0.2*24 = 4.8KN/m2

WDC = 4.8*1.85 + 1.155 = 10KN/m

WDW =0.07*23 = 1.61KN/m2

WDW = 1.61*1.85 = 3KN/m

Moments calculation :

10302
MDC = 8 = 1125KN.m/m

2
330
MDW = 8 = 337.5KN.m/m

1.85
Load fraction = 1.6764 = 1.1

P16000= 1.1 *71.17 = 78.3KN

P4000= 1.1 *17.8 = 19.6KN

+ MRR = 0
19.6 * 10.24 + 78.3 *14.51 + 78.3 * 18.78 RL * 30 = 0
RL = 93.6KN

Max. moment at 0

+ Mo = 0

Mmax + 78.3 * 4.27 93.6 * 15.49 = 0

MLL = Mmax = 1116KN.m/m

A reduction of 0.75 because of 4 lanes


MLL = 0.75 * 1116 = 837KN.m/m

15.24 15.24
I= L+38 = 30+ 38 = 0.224 0.3 ok

IM = 0.224 * 837 = 187.6

Mut = 1.25 * 1125 + 1.5 * 337.5 + 1.75(1116 + 187.5 ) = 4195KN.m/m

W- section is compact because of shear connectors so Lb < Lp

Mn = Mp = Fy * Zx , b = 0.9

Vu = 0.6 * Fy * Aw Vu = 0.9(0.6*Fy*Aw)
6
4195 x 10
Zx = 0.9345 = 13506x103 mm3

Choose W1000x371 with Zx = 18400 mm3 , Ix = 8160x106 mm4


Checking section for shear

+ MRR = 0

19.6 * 21.46 + 78.3 * 25.73 + 71.17 * 30 RL * 30 = 0


RL = 152.35KN = VLL

IVLL = 0.224 * 152.35 = 34.13KN

W DC . L 1030
VDC = 2 = 2 = 150KN

W DW . L 330
VDW = 2 = 2 = 45KN

Vut = 1.25 * 150 + 1.5 * 45 + 1.75 (152.35 + 34.13 ) = 581.34


KN

Vut 0.9(0.6*Fy*Aw) = 0.9(0.6*345*19.1*1000) = 3558 KN

Where Aw = tw*d

Vut 3558 KN so section is satisfactory to resist shear force

Check Serviceability
30000
Allowed deflection = 800 = 37.5mm

Overall depth of composite section = 0.04*L = 0.04*30 =1200mm satisfactory