Emerson Preset DL8000
Emerson Preset DL8000
Emerson Preset DL8000
DL8000 Preset
The DL8000 Preset is a rugged electronic preset that
provides precise custody transfer batches for petroleum,
Temperature Compensation
industrial chemicals, and other products. It accepts The DL8000 can accept an input from an Analog Input or
volumetric and mass inputs from turbine, Coriolis, RTD device. It then calculates a temperature volume
ultrasonic, or other flow measurement devices using single correction factor in accordance with the following
or linearized meter factors. (Pulse-generating meters are standards:
recommended for improved valve closure accuracy.)
Hydrocarbon Standards
The DL8000 also performs density, temperature, and
pressure corrections using the latest standards and API MPMS Chapter 11.1 (1980) / API2540 (1980) /
accurately calculates delivered volumes at standard ASTM D1250 / ANSI D1250 / IP200
conditions (60F, 15C, 20C, or user-selectable) using Tables: 5A, 5B, 5D, 6A, 6B, 6C, 6D, 23A, 23B, 23D, 24A,
double precision math. The DL8000 can control and blend 24B, 24C, 24D, 53A, 53B, 53D, 54A, 54B, 54C, 54D
up to four products sequentially or simultaneously (ratio API MPMS 11.1 (2004) / ASTM D1250-04 / IP200/04
blending). It can control up to 10 additives through metered ISO 91.1 (1992)
injection, and can store up to 30 recipes for blending. ISO 91.2 (1991) / IP3 (1988)
Tables: 59A, 59B, 59D, 60A, 60B, 60D
Density Correction GPA TP27 (2007) (supersedes TP-25) / API MPMS
Chapter 11.2.4
The DL8000 accepts density signals as a frequency, 420
mA, or through a communications device. It accepts inputs Tables: 23E, 24E, 53E, 54E, 59E, 60E
from a flowing density meter (such as a Micro Motion Ethanol Standards
frequency densitometer or a Micro Motion Coriolis meter).
The DL8000 corrects observed density to standard ABNT NBR 5992:2009
conditions and calculates the temperature and pressure OIML R22 (1973)
volume correction factors.
2 www.EmersonProcess.com/Remote
DL8000 June 2016
www.EmersonProcess.com/Remote 3
June 2016 DL8000
The liquid crystal display (LCD) is the same for both versions
and provides an 8-line by 40-column message area for
Measurement Canada
operator interface. The display uses a photo sensor and Measurement Canada is available for the DL8000. The
temperature sensor which can be set to automatically adjust Measurement Canada version of the DL8000 consists of a
contrast and backlighting for optimal viewing. CPU loaded with a Measurement Canada-approved
firmware, a power module, and 9 communications and/or
Light-emitting diodes (LEDs) display the status of alarms,
I/O modules housed in either cast aluminum casing or
operating mode, and permissive powers. LEDs are located to
stainless steel box with keypad and LCD display.
the right of the display on both versions.
Measurement Canada approves the following firmware and
user program versions:
DL8000 firmware version 2.31
Liquid Calcs version 2.31
Transaction History version 2.33
Printer version 2.31
Additives version 2.30
Batching version 2.34
Keypad Display Version 2.34
4 www.EmersonProcess.com/Remote
DL8000 June 2016
Memory
Boot Flash 256 KB for system initialization and diagnostics
Flash 16 MB for firmware image
SRAM 2 MB for historical data logs and configuration
Battery Backup User-replaceable
Type Sanyo 3 V CR2430 lithium
Normal use life 10 years while power is applied to unit
Backup life 1 year minimum while maintaining SRAM and RTC
data and no power is applied to unit
Shelf life 10 years (jumper disengaged)
Synchronous DRAM 32 MB for firmware execution and execution memory
Time Functions
Clock Type 32 KHz crystal oscillator with regulated supply, battery-backed, Year/Month/Day and
Hour/Minute/Second
Clock Accuracy 0.01%
Watchdog Timer Hardware monitor expires after 3 seconds and resets the processor
Communications
On Board EIA-232 (RS-232) Type Single
Port
Maximum Data 115.2 k bps
Rate
Ethernet Port 10BASE-T twisted pair. IEEE multi-segment 10 MB/second baseband
Ethernet.
Maximum 100 m (330 ft).
Segment
LOI Port Type EIA-232D (RS-232D) Standard
Maximum Data 115.2 k bps
Rate
Modules (optional) EIA-232 (RS-232) Type Single
Module
Maximum Data 115.2 k bps
Rate
EIA-422/485 Type Single
(RS-422/485)
Module Maximum Data 115.2 k bps
Rate
www.EmersonProcess.com/Remote 5
June 2016 DL8000
Inputs/Outputs
On Board Board Temperature 1% typical, 2% maximum
Accuracy
Voltage Monitor 0.75% typical, 1% maximum
Accuracy
Modules (optional) Analog Input-12 4 channels, 12 bits of resolution. For more information, refer to
Technical Specifications ROC800:AI.
Analog Input-16 4 channels, 16 bits of resolution. For more information, refer to
Technical Specifications ROC800:AI.
Alternating Current 6 channels. For more information, refer to Technical Specifications
I/O ROC800:ACIO.
Advance Pulse 4 channels, 4 single or 2 dual (one configurable as a densitometer
Module input and one as a pulse output). For more information, refer to
Technical Specifications ROC800:APM.
Analog Output 4 channels. For more information, refer to Technical Specifications
ROC800:AO.
Discrete Input 8 channels. For more information, refer to Technical Specifications
ROC800:DI.
Discrete Output 5 channels. For more information, refer to Technical Specifications
ROC800:DO.
Discrete Output 5 channels. For more information, refer to Technical Specifications
Relay ROC800:DOR.
HART Input/Output 4 channels, each capable of communications with up to 5 HART
devices (when in input multi-drop mode). Supports up to 5 HART
modules in slots 1-5. For more information, refer to Product Data Sheet
ROC800:HART2.
Pulse Input 2 channels, user-selectable high speed or low speed per channel. For
more information, refer to Technical Specifications ROC800:PI.
RTD Input 2 channels. For more information, refer to Technical Specifications
ROC800:RTD.
Power
Requirements 115 to 240 V ac (+ 10%/ 15%), 50 to 60 Hz, 1-phase 30-watt nominal
Physical
Keypad 18 rugged, Hall-effect push keys which are impervious to chemicals commonly associated
with petroleum applications. A sealable Weights & Measures switch is incorporated into the
front panel to provide security to flow measurement parameters.
Display A single, 8-line by 40-column super-twist LCD display. Status LEDs identifying alarm,
permission power, and operational mode (Auto or Manual).
6 www.EmersonProcess.com/Remote
DL8000 June 2016
www.EmersonProcess.com/Remote 7
June 2016 DL8000
CE / ATEX Certified by IEC IECExas Model W40176 per certification number IECEx SIR
08.0019
Certified by Sira as Model W40176 per certification number SIRA 08ATEX1063
Product Markings: Ex d IIB T6 (-40C T 65C), IP66
II 2 G 0081
Note: Temperature range for LCD Display is -20C T 65C
Evaluated per Approval IEC 60079-0 : 20ll ed. 6
Standards IEC 60079-l :2O07-04 ed. 6
EN 60079-0:2012
EN 60079-1:2007
Product Marking for Measurement Certified by Measurement Canada as DL8000.
Metrology (Industry) Approval No.: AV-2426C
Canada
NTEP Certified by NTEP as Model W40161 per certificate number 08-056A1
Evaluated per Approval NIST Handbook 44 (2010)
Standards NCWM Publication 14 (2010)
NMi Certified by NMi as DL8000 per certificate number TC7661 revision 1
(MID Standards) Valid I/O Configurations for MID Approval:
To maintain CE approval, you can only use the following I/O modules
connected to the valid I/O types as shown in the table below.
Review the corresponding certificates to ensure full compliance.
I/O Modules I/O Type 1 I/O Type 2
AI-12 Pressure Density
DI Feedback Signals
RS 485 Communication
RTD Temperature
DO Control Signals
APM Pulse In (level B)
HART Temperature
AC I/O Control Signals Feedback Signals
(output) (input)
Evaluated per Approval OIML R117-1 Edition 2007 (E)
Standards WELMEC guide 8.8
Miscellaneous Approvals GOST Certified by Gosstandart as Models W40176 and W40161 per certification
number 8468248
INMETRO Certified by INMETRO as Model 40176
NCC 14.2252
Marking: Ex d IIB T6 (-40C T 65C) Gb IP66
8 www.EmersonProcess.com/Remote
DL8000 June 2016
II 3 GD
Evaluated per Approval EN 60079-0:2006
Standards EN 60079-0:2009
EN 60079-15:2005
EN 61241-0:2006
EN 61241:2004
RoHS (China)
www.EmersonProcess.com/Remote 9
June 2016 DL8000
10 www.EmersonProcess.com/Remote
DL8000 June 2016