RD7000 User Guide
RD7000 User Guide
RD7000 User Guide
Preface
About this guide
This guide provides basic operating instructions for the RD7000 receiver and transmitter.
Please read this guide in its entirety before attempting to operate the RD7000.
This guide is intended as a portable reference only. For detailed instructions, please
refer to the RD7000 operation manual, which is available for download from
www.radiodetection.com. To download the manual go to the Library section, which
is accessible via the menu; next go to Cable and Pipe Locators and then select User
Manuals and click the RD7000 Operation Manual link.
The online User Manual library also contains links to the SurveyCERT and eCAL
manuals.
Copyright statement
This user guide is Copyright 2008 Radiodetection Ltd. Radiodetection is a subsidiary of
SPX Corporation, all rights reserved.
Trademarks
RD7000, RD4000, flexitrax and eCAL are trademarks of Radiodetection Ltd.
Important notices
When reporting any problems to your Radiodetection Dealer or Supplier it is important to
quote the unit serial number and the purchase date.
WARNING! This equipment is NOT approved for use in areas where hazardous
gases may be present.
WARNING! When
using the transmitter, switch
off the unit and disconnect
cables before removing the battery pack.
Reduce audio level before using the earpiece.
Batteries should be disposed of in accordance with your companys work practice, and/
or any relevant laws or guidelines in your country.
This instrument, or family of instruments, will not be permanently damaged by
reasonable electrostatic discharge and has been tested in accordance with IEC 801-2.
However, in extreme cases temporary malfunction may occur. If this happens, switch off,
wait and switch on again. If the instrument still malfunctions, disconnect the batteries for
five seconds and then reinstall and switch the unit on.
WARNING! The RD7000 will detect almost all buried conductors but there are
some objects that do not radiate any detectable signal. The RD7000, or any other
electromagnetic locator, cannot detect these objects so proceed with caution.
There are also some live cables which the RD7000 will not be able to detect in
Power mode. The RD7000 does not indicate whether a signal is from a single
cable or from several in close proximity.
Training
Radiodetection provides training services for most Radiodetection products. Our
qualified instructors will train equipment operators or other personnel at your preferred
location or at Radiodetection headquarters. For more information go to
www.radiodetection.com or contact your local Radiodetection representative.
RD7000 receiver
2
1
3
6
7
8 9
15 14 10 11 12
13
14
16 23
17
24
18 19 20 21 22
Receiver features 20. Operating mode indicator.
4
6
7 6
10 11 12 17
18
8
13 19
14
15
16
9 20
Transmitter features 16. CD Mode indicator: Indicates
that the transmitter is in Current
1. Keypad.
Direction Mode.
2. LCD.
17. Voltage warning indicator:
3. Removable accessory tray. Indicates that the transmitter is
Transmitter keypad outputting potentially hazardous
voltage levels.
4. Power key: Switches the unit
on and off. Open the transmitter 18. Volume icon: Displays the volume
menu. level.
5. key: Selects frequency. Menu 19. Pairing icon (Tx 3B and Tx10B
navigation key. only): Appears when the
transmitter and RD8000 receiver
6. Up and down arrows: Adjusts the
are connected via iLOC
output signal. Scrolls through the
menu options. 20. Bluetooth icon (Tx 3B and
Tx10B only). Indicates status of
7. Measure key: Toggles
Bluetooth connection Flashing
measurement display between
icon means pairing is in progress.
volts, current and impedance.
Note: displayed measurements are
based on the currently selected
mode or the attached accessory, if
applicable. Opens a submenu.
Transmitter screen icons
8. Battery icon: Indicates the battery
level.
9. Alphanumeric description of
selected operation mode.
10. Standby icon: Appears when the
transmitter is in Standby Mode.
11. Output level: Displays transmitter
output power.
12. Clamp icon: Indicates when a
clamp is connected.
13. DC icon: Appears when the
transmitter is powered from a DC
source.
14. Induction indicator: Appears when
the transmitter is in Induction
Mode.
15. A-Frame: Indicates when the
transmitter is in Fault-Find Mode.
Before you begin
IMPORTANT! Please read this section before you attempt to operate the RD7000!
System setup
It is important that you set up the system according to your personal preferences and
operating requirements before you conduct your first survey. You can set the system up
using the RD7000 menu as described below.
Before changing settings, ensure the receiver or transmitter is switched on by pressing
the keypad Power Key for two seconds.
Units
The RD7000 allows you to work in Metric or Imperial (US customary) units. To select
your preferred units of measurements:
1. Press the Power Key momentarily to enter the menu,
2. Scroll to the UNIT option using the arrow keys,
3. Press the Right arrow key to enter the UNIT submenu,
4. Scroll up or down using the up and down arrows to select Metric or Imperial
units,
5. Press the Left arrow to accept your selection and return to the main menu.
6. Press the Power Key to return to the main operation screen.
Battery
The RD7000 receiver and transmitter support both NiMH or ALK batteries. It is important
that you set the system to match the currently installed battery type to ensure optimal
performance and correct battery level indication. To set your battery type:
1. Press the Power Key momentarily to enter the menu,
2. Scroll to the BATT option using the arrow keys,
3. Press the Right arrow key ( on the transmitter) to enter the BATT submenu,
4. Scroll up or down to select the correct battery type,
5. Press the Left arrow ( on the transmitter) to accept your selection and return
to the main menu.
6. Press the Power Key to return to the main operation screen.
The RD7000 is now ready to use.
Shutting down
To switch the receiver or the transmitter off, press and hold the keypad Power Key for
two seconds.
Using the menu
The RD7000 receiver and transmitter menus allow you to select or change system
options. Once entered, the menu is navigated using the arrow keys. Navigation is
consistent on both the transmitter and the receiver. When in the menu, most on-screen
icons will temporarily disappear and the menu options will appear in the bottom left-hand
corner of the LCD. Note that when browsing the receiver menu, the and Antenna keys
act as Left and Right arrows. When browsing the transmitter menu the and keys
act as Left and Right arrows. The Right arrow enters a submenu and the Left arrow
returns to the previous menu.
Note: When you select an option and press the Left arrow, the option will be enabled
automatically.
Using accessories
Both the transmitter and receiver are compatible with a wide range of accessories,
including all RD4000 accessories. Use clamps to help apply a signal to pipeline or
live wire. Use an A-Frame to provide the RD7000 receiver with advanced fault-finding
capabilities.
When an accessory is connected, the receiver or transmitter will instantly recognize it
and will enable the mode appropriate to the accessory. For example, attaching an
A-Frame (TL or PL only) to the RD7000 receiver will automatically switch the receiver
to fault-find mode and limit the number of available frequencies to those that are
compatible with the A-Frame. The LCD will also display an icon of the accessory and
will remove any non-essential icons from the screen.
Locating pipes and cables
Passive Frequencies
Passive frequency detection takes advantage of signals that are already present on
buried metallic conductors. The RD7000 supports two types of passive frequencies:
power and radio signals. You can detect these frequencies without the aid of
the transmitter.
Active Frequencies
Active frequencies are applied direct to the pipe or cable using the transmitter. The
transmitter can apply a signal using two methods: induction and direct connection.
Induction
The transmitter is placed on the ground over or near the survey area. You select the
appropriate frequency. The transmitter will then induce the signal indiscriminately to
any nearby metallic conductor. In induction mode, using higher frequencies is generally
recommended as they are inducted easier onto nearby conductors.
Direct connection
In direct connection, you connect the transmitter directly to the pipe or cable you wish to
survey. The transmitter will then apply a discreet signal to the line, which you can locate
using the receiver. This method provides the best signal on an individual line and enables
the use of lower frequencies, which can be traced for longer distances.
Connecting the transmitter to a pipe or line requires the use of a direct connection lead
or clamp and a ground stake to complete the circuit.
WARNING! Direct connection to live wires is POTENTIALLY LETHAL.
Direct connections should be attempted by fully qualified personnel only!
Signal clamps
A signal clamp can apply a signal to a live line without breaking the connection. Signal
clamps are connected to the transmitters accessory socket. Radiodetection supplies
a range of signal clamps to suit most applications. Note that the RD7000 is fully
compatible with the RD4000 range of signal clamps.
Stethoscopes
At times, it may not be possible to use a clamp around a cable because of congestion
or inaccessibility. A stethoscope antenna should be used in place of a clamp to identify
cables.
Radiodetection supplies a range of stethoscopes to suit most applications. As with
signal clamps RD7000 is fully compatible with the R4000 range of stethoscopes.
To use a stethoscope, connect it to the receivers accessory socket. The receiver will
automatically detect the device and filter out location modes that are irrelevant.
Locating sondes
Sondes are self-contained, battery powered transmitters that are useful for tracking
non-metallic pipes. The RD7000 PL, DL and TL can detect a range of sonde
frequencies, including those transmitted by flexisondes and the P350 flexitrax crawler
(visit www.radiodetection.com for more information on other Radiodetection products).
To locate a sonde
1. Set up the sonde according to the sondes user documentation. Make sure
the sonde is sufficiently powered for the duration of the survey; note the sondes
operating frequency,
2. Deploy the sonde into the pipe or duct as required,
3. On the receiver, select the sonde frequency by pressing the key until the
desired frequency is displayed on the LCD and the sonde icon is visible,
4. Set the gain to approximately 60-80%,
A sonde radiates a peak field from the center of its axis with ghost signals at each side
of the peak. Move the receiver to one side and then along the axis of the sonde forwards
and backwards to detect the ghost signals.
Radiodetection recommends locating the ghost signals as finding them confirms the
position of the main peak. To lose the ghost signals, reduce the sensitivity of the receiver;
this should leave only the main peak signal detectable.
With the receiver sensitivity set as desired, propel the sonde along three or four meters
and stop. Place the receiver over the estimated position of the sonde and:
1. Hold the receiver vertically with the blade in line with the sonde,
2. Move the receiver backwards and forwards with the blades orientation parallel
to the sonde,
3. Stop when the bar graph indicates a clear peak,
4. Rotate the receiver until the blades orientation is perpendicular to the sonde,
stop when the bar graph indicates a clear peak,
5. Move the receiver from side to side until the bar graph indicates a clear peak.
When the receiver locates a peak signal, it will automatically calculate the depth of the
sonde. Observe the depth reading while moving the receiver from side to side; the
lowest reading will be the correct location.
Repeat each step in smaller increments with the receiver blade resting on or near the
ground. The receiver should now be directly above the sonde with the blade in line with
the sonde; mark this position.
Propel the sonde a further three to four meters along the pipe to pinpoint its location.
Mark the location as required. Repeat the procedure along the route at similar intervals.
Note, while tracking the sonde, altering the receivers sensitivity is not required unless
the pipes depth, or the distance between receiver and sonde changes.
Fault-finding
The RD7000 TL and PL have the ability to detect cable faults accurately using an
accessory A-Frame. Fault-finding works by detecting signal to ground bleeding caused
by damaged cable sheaths. For a detailed guide to fault-finding, please refer to the
RD7000 operation manual.
The sole and exclusive warranty for any name and dealers name) within the
Radiodetection product found to be warranty period. This warranty covers
defective is repair or replacement of the only the hardware components of the
defective product at Radiodetections Radiodetection product. Data storage
sole discretion. Repaired parts or media or accessories must be removed
replacement products will be provided prior to submission of the product for
by Radiodetection on an exchange basis warranty service.
and will be either new or refurbished to be Radiodetection will not be responsible
functionally equivalent to new. for loss or erasure of data storage media
In the event this exclusive remedy is or accessories. Radiodetection is not
deemed to have failed of its essential responsible for transportation costs and
purpose, Radiodetections liability shall risks associated with transportation of
not exceed the purchase price of the the product. The existence of a defect
Radiodetection product. In no event will shall be determined by Radiodetection in
Radiodetection be liable for any direct, accordance with procedures established by
indirect, special, incidental, consequential Radiodetection.
or punitive damages (including lost profit) This warranty is in lieu of any other
whether based on warranty, contract, tort warranty, express or implied, including
or any other legal theory. any implied warranty of merchantability or
Warranty services will be provided only fitness for a particular purpose.
with the original invoice or sales receipt
(indicating the date of purchase, model
condition and standard other than
This warranty does not cover:
prescribed by RD
a. periodic maintenance and repair or
parts replacement due to wear and viii. repair or attempted repair
tear by persons who are not RD
warranted and certified repair
b. consumables (components that
houses
are expected to require periodic
replacement during the lifetime of a ix. adjustments or adaptations
product such as non-rechargeable without RDs prior written consent,
batteries, bulbs, etc.) including:
c. damage or defects caused by use, i. upgrading the product
operation or treatment of the product beyond specifications or
inconsistent with its intended use features described in the
instruction manual, or
d. damage or changes to the product as
a result of: ii. modifications to the product
to conform it to national
i. misuse, including: - treatment
or local technical or safety
resulting in physical, cosmetic or
standards in countries other
surface damage or changes to
than those for which the
the product or damage to liquid
product was specifically
crystal displays
designed and manufactured
ii. failure to install or use the product
x. neglect e.g. opening of cases
for its normal purpose or in
where there are no user
accordance with RD instructions
replaceable parts
on installation or use
xi. accidents, fire, liquids, chemicals,
iii. failure to maintain the product in
other substances, flooding,
accordance with RD instructions
vibrations, excessive heat,
on proper maintenance
improper ventilation, power
iv. installation or use of the product surges, excess or incorrect
in a manner inconsistent with supply or input voltage, radiation,
the technical or safety laws or electrostatic discharges including
standards in the country where it lighting, other external forces and
is installed or used impacts.
v. virus infections or use of the
product with software not
provided with the product or
incorrectly installed software
vi. the condition of or defects in
systems with which the product is
used or incorporated except other
RD products designed to be
used with the product
vii. use of the product with
accessories, peripheral equipment
and other products of a type,
Notes
Radiodetection Ltd.
Western Drive, Bristol BS14 0AF, UK
Tel: +44 (0) 117 976 7776 Fax: +44 (0) 117 976 7775
Email: [email protected]
Radiodetection
154 Portland Road, Bridgton, ME 04009, USA
Tel: +1 (207) 647 9495 Toll Free: +1 (877) 247 3797
Fax: +1 (207) 647 9496 Email: [email protected]
www.radiodetection.com
90/UG078ENG/02