Installation Section 2
___________________________________________________________________________

Sub-section Page
__________________________________________________________________________________________________
2.1 Hardware check 2/2
__________________________________________________________________________________________________________

_____________________________________________________________________________________________________________________________________________________________________________
2.2 Connections 2/4
__________________________________________________________________________________________________________
2.2-1 Installing the software key 2/4
__________________________________________________________________________________________________________
2.2-2 Connection to main power source 2/4
__________________________________________________________________________________________________________
2.2-3 Connecting the FTX 417-20 terminal to the PLC 2/5
__________________________________________________________________________________________________________
2.2-4 Connecting the FTX 507 terminal to the PLC 2/5
__________________________________________________________________________________________________________
2.2-5 Connecting the IBM PS/2 or compatible PC to the PLC 2/6
__________________________________________________________________________________________________________

_____________________________________________________________________________________________________________________________________________________________________________
2.3 Software Installation 2/8
__________________________________________________________________________________________________________
2.3-1 Preliminary steps 2/8
__________________________________________________________________________________________________________
2.3-2 Installation procedure 2/8
__________________________________________________________________________________________________________

__________________________________________________________________________________________________________
2.4 PL7-3 Files 2/10
__________________________________________________________________________________________________________

This section ends on page 2/10

___________________________________________________________________________
2/1
A
___________________________________________________________________________
2.1 Hardware Check
_________________________________________________________________________________________________________________________

To use PL7-3 software, you need the following hardware :


An FTX 417-20, an FTX 507 terminal or an IBM PS/2 or compatible PC (see Section
1.2 for required configuration), equipped with the OS/2 operating system and the
X-TEL or MINI X-TEL software workshop.
A terminal / PLC connecting cable, in the case of an FTX 417-20 or FTX 507 terminal.
A terminal / PLC connection assembly in the case of an IBM PS/2 or compatible PC,
composed of :
- An RS 232C / current loop converter
- A converter / micro-computer connecting cable with a 9-pin connector
- A converter / micro-computer connecting cable with a 25-pin connector
- A converter / PLC connecting cable.
A PL7-3 software pack comprising :
- Four 3 1/2" diskettes
- A software key
- The PL7-3 V5 reference manual TXT DR PL7 3 V5E
- The OFB diagnostic manual TXT DM FBD V4E
- This manual TXT DM PL7 3 V5E.

___________________________________________________________________________
2/2
Installation 2
A
___________________________________________________________________________

Terminal Terminal/PLC Software pack


connection assembly

FTX 417-20 T FTX CB 7 4 Diskettes

FTX 507 T FTX CB 7 5

Software key

TSX TAC 03

TSX CTC 00
Converter/PLC cable
TE approved
IBM PS/2 or
compatible PC
TSX TE 01
RS232/CL converter


Documentation
TXT DR PL7 3 V5E
TXT DM PL7 3 V5E
TXT DM FBD V4E

TSX CTC 01
Converter/microcomputer
cable

TSX CTC 02 X X
Converter/microcomputer
cable

TSX SCC 02
Software key support

___________________________________________________________________________
2/3
A
___________________________________________________________________________
2.2 Connections
_________________________________________________________________________________________________________________________

The connections specific to the terminal (monitor, keyboard, mouse, printer) are
described in the manufacturer's documentation. This section therefore describes only
the installation of the software key and the following connections :
The connection of the terminal to the main power source.
The connection of the terminal to the PLC.

_________________________________________________________________________________________________________________________

2.2-1 Installing the software key


Install the software key in the empty slot in the software key support.

This operation must be done with the terminal powered down.

Note
The software key contains the right of use necessary to access the PL7-3 software.
The Key Manager delivered with the software workshop allows this right of use to be transferred
to the master key. This makes the PL7-3 software key unusable and it can therefore be removed,
thus freeing the corresponding slot on the software key support.

_________________________________________________________________________________________________________________________

2.2-2 Connection to the main power source


Before making any connections to the main power source, check that each of the
elements of the system is correctly adjusted to operate on your mains power voltage
(220V or 110V).

Then, observing the precautions indicated in the manufacturers' documentation, con-


nect the various elements to the main power source :
Terminal
RS232/current loop converter
PLC.

___________________________________________________________________________
2/4
Installation 2
A
___________________________________________________________________________
2.2-3 Connecting the FTX 417-20 terminal to the PLC
This connection requires the T FTX CB 7 4 connecting cable

T FTX CB 7 4
Mains
_________________________________________________________________________________________________________________________

2.2-4 Connecting the FTX 507 terminal to the PLC


This connection requires the T FTX CB 7 5 connecting cable

Serial link
connector

25-pin
T FTX CB 7 5 parallel link
connector

Mains

___________________________________________________________________________
2/5
A
___________________________________________________________________________
2.2-5 Connecting the IBM PS/2 or compatible PC to the PLC
This connection requires the TSX TAC 03 connection kit and is performed in three
steps :

1 Checking the configuration of the TSX TE 01 converter


The converter is normally adjusted at the factory, however it is advisable to check the
positions of the switches and jumpers :
Remove the cover from the case by inserting a screwdriver in one of the slots on the
side of the case and turning it until the cover can be lifted off.
Check that the positions of the 13 switches and the 4 jumpers are correct (see the
diagram below).
Set switch S4 to the required voltage : 110V or 220V.

X7 Front panel

1 2 3
X6
1 2 3
X5 Top view case open
S1 S2 S3
1 2 3
1 1 3 4 1 3
X4
1 2 3 2 3 4 2 5 2 4

IMPORTANT

The connection may be damaged if these settings are not correct, or if any other type
of converter is used.

___________________________________________________________________________
2/6
Installation 2
A
___________________________________________________________________________
2 Connecting the PLC programming port to the converter
This connection uses the TSX CTC 00, wired as shown below :
1
+REC 2 Red
1 R+
3
+EMI 4 White 2 R-
5
OV 6 White
3 T+
-REC 7
-EMI 8 Blue 4 T-
+12V 9
5
9-pin connector on LINE CONNECTION
PLC programming port 5-pin screw terminal
on the converter
3 Connecting the converter to the computer
This connection uses the TSX CTC 01 or TSX CTC 02 cable connected between the
9-pin or 25-pin "serial link" connector on the computer and the 25-pin connector (V24/
RS-232 C CONNECTION) on the converter.

Mains IBM PS/2

Software key support

Mains

TSX CTC 00

TSX CTC 02

Converter
Mains
___________________________________________________________________________
2/7
A
___________________________________________________________________________
2.3 Software Installation
_________________________________________________________________________________________________________________________

2.3-1 Preliminary steps


Before installing the PL7-3 software on the hard disk, it is recommended that you :
Read the license and guarantee certificates concerning the restrictions that apply to
copying and installing the software.
Make back-up copies of the original installation diskettes and use the back-up copies
to work with, so as to avoid accidental damage to the originals.

IMPORTANT
The PL7-3 diskettes are delivered set to the "write protect" position, which should not
be altered.

_________________________________________________________________________________________________________________________

2.3-2 Installation procedure


The following operations must be carried out before installing the PL7-3 software :
1 Check that the X-TEL or MINI X-TEL software workshop is already installed
(refer to the corresponding instruction manual).
Should this be the case, continue installing PL7-3. Otherwise you must install the
software workshop first (refer to the corresponding instruction manual).

2 Close all ongoing sessions (refer to the corresponding instruction manual).

___________________________________________________________________________
2/8
Installation 2
A
___________________________________________________________________________
Installing PL7-3 software
Start a full-screen OS/2 session,
Insert PL7-3 diskette No. 1 in the disk drive,
Identify the drive containing the diskette (a: or b:) and press <Enter>,
After the new prompt (for example : [a:\] or [b:\]), enter the command install and press
<Enter>,
Follow the procedure displayed on the screen : replace diskette No.1 by diskette No.2
when requested to do so and then press <Enter>,
When the installation is complete, insert the Grafcet OFB disk in the disk drive, then
enter the command install and press <Enter>,
When the installation is complete, install the OFBs in the PL7-DIAG family in the same
way (refer to the corresponding instruction manual).

Note
If PL7-3 already exists on the station where PL7-3 GLD or PL7-3 GLT is being installed, a warning
message is displayed. Installation can then be interrupted by pressing <Q> on the keyboard. The
same is also true when installing PL7-3, if PL7-3 GLD or PL7-3 GLT already exist on the station.

Important
Under OS/2 2.1, if the screen display under PL7-3 has been altered, reinstall the
X-TEL or MINI X-TEL software workshop using the command :
install FIX21
At the end of installation, reinitialise the work station using the command :
<Ctrl><Alt><Del>.

___________________________________________________________________________
2/9
A
___________________________________________________________________________
2.4 PL7-3 Files
_________________________________________________________________________________________________________________________

PL7-3 files are identified by a name of 8 characters maximum, followed by a suffix of 3


characters which indicates the type of file.
They are stored in the various sub-directories of the software workshop.
The application and modular documentation files are stored by the station under the
PL7_3 sub-directory :

APP xxx.APP application description


xxx.IOC I/O configuration
PL7_3 APPLI xxx.BIN PL7-3 application binary file

xxx.DAT data storage


xxx.XR1 cross-references
to xxx.XR4 cross-references
xxx.TIT title page
xxx.DES general information
xxx.CA1 I/O wiring (racks 0/1)
to xxx.CA8 I/O wiring (racks E/F)
xxx.NET network information
xxx.COM program comments
xxx.CRT documentation cartridge
xxx.DOC documentation printed in a file
xxx.SYM table of mnemonics V3 (binary)
xxx.MRK marker for cross-references
MOD xxx.MOD table of modules
xxx.LAD Ladder source archive (1)
xxx.LIT Literal source archive (2)
xxx.GR7 Grafcet source archive
xxx.CST constant word source archive
xxx.OBC OFB constant word source archive
xxx.OBM OFB constant word source archive
(elementary module level)
xxx.CDE documentation menu
xxx.SCY table of V4 mnemonic symbols (ASCII)
xxx.COM module comments
xxx.MCR V4 macro-modules
xxx.M5M V5 macro-modules
xxx.DDA data screen
xxx.DPR program address
PL7-3 also manages the following files :
xxx.TMP temporary file
xxx.BAK back-up file
xxx.OFB OFB file (in system space only).
(1) Except PL7-3 GLT (2) Except PL7-3 GLD